Kichler 44086BK Guía de instalación

Tipo
Guía de instalación

Este manual también es adecuado para

Date Issued: 09/28/17 IS-44086-US
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starting and during the installation.
Before Installing:
All installations should comply with National and local electrical
codes. If you have any doubts concerning installation contact a
qualied licensed electrician.
1) Find the appropriate threaded holes on mounting strap[1].
Assemble mounting screws[2] into threaded holes.
2) Attach mounting strap to outlet box[4] using strap mounting
screws[3]. Mounting strap can be adjusted to suit position of
xture.
3) Grounding instructions: (See Illus. A or B).
A) On xtures where mounting strap is provided with a
hole and two raised dimples. Wrap ground wire from
outlet box around green ground screw, and thread into
hole.
B) On xtures where a cupped washer is provided. Attach
ground wire from outlet box under cupped washer and
green ground screw, and thread into mounting strap.
If xture is provided with ground wire. Connect xture ground
wire to outlet box ground wire with wire connector. (Not pro-
vided.) After following the above steps. Never connect ground
wire to black or white power supply wires.
4) Make wire connections (connectors not provided). Reference
chart below for correct connections and wire accordingly.
5) Push xture to ceiling, carefully passing mounting screws
through holes in canopy. NOTE: Be certain wires do not get
pinched between canopy and ceiling.
6) Use knobs[6] and lockwashers[7] to secure canopy. Tighten to
secure.
7) Attach the three (3) arms[5] with the three (3) threaded
knobs[8] securely.
8) Raise the glass shade[9].
9) Take the lower frame[10] and supporting the glass shade tilt
and hook onto the three (3) arms.
10) Install the recommended bulbs.
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
AB
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth) *Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.) Neutral Wire
2
1
3
4
7
6
8
5
9
10
Date Issued: 09/28/17 IS-44086-US
Estamos aquí para ayudarle 866-558-5706
Horario: Lunes-Viernes 9am a 5pm EST (hora ocial del este)
Antes de instalar:
Todas las instalaciones deben cumplir con las normas nacionales y
locales de códigos. Si tiene alguna duda sobre la instalación, pón
gase en contacto con un electricista calicado.
1) Encuentre los oricios roscados adecuados en la correa de
montaje[1]. Montar los tornillos de montaje[2] en los oricios
roscados.
2) Fije la correa de montaje a la caja de salida[4] con los tornil-
los de jación de la correa[3]. La correa de montaje se puede
ajustar para adaptarse a la posición del aparato.
3) Instrucciones para poner a tierra: (Ver Ilustraciones A o B).
A) En artefactos donde se suministra la abrazadera de
montaje con un agujero y dos depresiones onduladas.
Envuelva el conductor de tierra de la caja de salida
alrededor del tornillo de tierra verde y atornille en el
agujero.
B) En artefactos donde se suministra una arandela
cóncava. Fije el conductor de tierra de la caja de salida
debajo de la arandela cóncava y el tornillo de tierra
verde y enrosque en la abrazadera de montaje.
Si se suministra el artefacto con conductor de tierra. Conecte
el conductor de tierra del artefacto al conductor de tierra de
la caja de salida con conector de tierra después de seguir los
pasos anteriores. Nunca conecte el conductor de tierra a los
alambres de alimentación eléctrica negros o blancos.
4) Haga las conexiones de los alambres. Re érase a la tabla de
abajo para realizar las conexiones correctas de los cables. 
5) Empuje la jación al techo, pasando cuidadosamente los tornil-
los de montaje a través de los oricios de la cubierta. NOTA:
Asegúrese de que los cables no queden atrapados entre el
techo y el techo.
6) Utilice las perillas[6] y las arandelas de seguridad[7] para
asegurar el dosel. Apriete para asegurar.
7) Fije rmemente los tres (3) brazos[5] con los tres (3) tornillos
roscados[8].
8) Suba la cortina de vidrio[9].
9) Tome el bastidor inferior[10] y apoye la inclinación de la cortina
de vidrio y el gancho en los tres (3) brazos.
10) Instale las bombillas recomendadas.
ARANDELA
CONCAVA
TIERRA DE LA
CAJA DE SALIDA
TORNILLO DE TIERRA,
VERDE
DEPRESIONES
TIERRA
ARTEFACTO
CONECTOR DE ALAMBRE
TIERRA DE LA
CAJA DE SALIDA
TORNILLO DE TIERRA,
VERDE
TIERRA
ARTEFACTO
AB
Conectar el alambre de
suministro negro o rojo al
Conectar el alambre de
suministro blanco al
Negro Blanco
*Cordon paralelo (redondo y liso) *Cordon paralelo (cuadrado y estriado)
Claro, marrón, amarillio o negro
sin hebra identificadora
Claro, marrón, amarillio o negro
con hebra identificadora
Alambre aislado (diferente del verde)
con conductor de cobre
Alambre aislado (diferente del
verde) con conductor de plata
*Nota: Cuando se utiliza alambre paralelo
(SPT I y SPT II). El alambre neutro es de forma
cuadrada o estriada y el otro alambre será de
forma redonda o lisa. (Vea la ilustracíón). Hilo Neutral
PRECAUCIÓN – RIESGO DE DESCARGA ELÉCTRICA
Desconecte la electricidad en el panel principal del interruptor
automático o caja principal de fusibles antes de comenzar y
durante la instalación.
2
1
3
4
7
6
8
5
9
10
Date Issued: 09/28/17 IS-44086-CB
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starting and during the installation.
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
2
1
3
4
7
6
8
5
9
10
Before Installing:
All installations should comply with National and local electrical
codes. If you have any doubts concerning installation contact a
qualied licensed electrician.
1) Find the appropriate threaded holes on mounting strap[1].
Assemble mounting screws[2] into threaded holes.
2) Attach mounting strap to outlet box[4] using strap mounting
screws[3]. Mounting strap can be adjusted to suit position of
xture.
3) Grounding instructions: (See Illus. A or B).
A) On xtures where mounting strap is provided with a
hole and two raised dimples. Wrap ground wire from
outlet box around green ground screw, and thread into
hole.
B) On xtures where a cupped washer is provided. Attach
ground wire from outlet box under cupped washer and
green ground screw, and thread into mounting strap.
If xture is provided with ground wire. Connect xture ground
wire to outlet box ground wire with wire connector. (Not pro-
vided.) After following the above steps. Never connect ground
wire to black or white power supply wires.
4) Make wire connections (connectors not provided). Reference
chart below for correct connections and wire accordingly.
5) Push xture to ceiling, carefully passing mounting screws
through holes in canopy. NOTE: Be certain wires do not get
pinched between canopy and ceiling.
6) Use knobs[6] and lockwashers[7] to secure canopy. Tighten to
secure.
7) Attach the three (3) arms[5] with the three (3) threaded
knobs[8] securely.
8) Raise the glass shade[9].
9) Take the lower frame[10] and supporting the glass shade tilt
and hook onto the three (3) arms.
10) Install the recommended bulbs.
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
AB
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth) *Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.) Neutral Wire
Date Issued: 09/28/17 IS-44086-CB
INSTRUCTIONS
For Assembling and Installing Fixtures in Canada
Pour L’assemblage et L’installation Au Canada
Nous sommes là pour vous aider 866-558-5706
Heures : du lundi au vendredi, de 9h à 17h (heure de l’Est)
ATTENTION – RISQUE DE DÉCHARGES ÉLECTRIQUES -
Couper le courant au niveau du panneau du disjoncteur du
circuit principal ou de la boîte à fusibles principale avant de
procéder à l’installation.
Avant d’installer:
Toutes les installations doivent être conformes aux normes
nationales et locales codes. Si vous avez des doutes quant à
l’installation, contactez un électricien qualié agréé.
1) Trouver les trous letés appropriés sur la barrette de
montage[1]. Vissez les vis de montage dans les trous
letés[2].
2) Vissez la bande de montage sur la boîte de jonction [4] en util-
isant les vis de xation de la sangle [3].. La barrette de mon-
tage peut etre ajustée pour convenir à la position de l’applique.
3) Connecter les ls. Se porter au tableau ci-dessous pour faire les
connexions.
4) Enfoncez le luminaire sur le plafond, en passant soigneuse-
ment les vis de xation dans les trous dans le voile.
REMARQUE: Soyez certain que les ls ne sont pas pincés
entre le dos et le plafond.
5) Utiliser les boutons[6] et les dispositifs de verrouillage[7] pour
sécuriser la voûte. Serrez pour sécuriser.
6) Fixez les trois (3) bras [5] avec les trois (3) boutons letés [8]
en toute sécurité.
7) Relever l’ombre de verre [9].
8) Prenez le cadre inférieur [10] et soutenez l’inclinaison de
l’inclinaison du verre et accrochez-vous sur les trois (3) bras.
9) Insérez les ampoules recommandées.
Connecter le fil noir ou
rouge de la boite Connecter le fil blanc de la boîte
A Noir A Blanc
*Au cordon parallèle (rond et lisse) *Au cordon parallele (à angles droits el strié)
Au bransparent, doré, marron, ou
noir sans fil distinctif
Au transparent, doré, marron, ou
noir avec un til distinctif
Fil isolé (sauf fil vert) avec
conducteur en cuivre
Fil isolé (sauf fil vert) avec
conducteur en argent
*Remarque: Avec emploi d’un fil paralléle
(SPT I et SPT II). Le fil neutre est á angles
droits ou strié et l’autre fil doit étre rond ou
lisse (Voir le schéma). Fil Neutre
2
1
3
4
7
6
8
5
9
10
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Kichler 44086BK Guía de instalación

Tipo
Guía de instalación
Este manual también es adecuado para