Firman ECO1500 El manual del propietario

Categoría
Generadores de poder
Tipo
El manual del propietario
Premium series:
ECO1500
OWNERS MANUAL
®
Read all safety precautions and instructions carefully
before operating equipment.
Ensure engine is stopped and level before performing
any maintenance or service.
IMPORTANT:
Record product information to reference when ordering parts or
obtaining warranty coverage.
Specification:
Serial Number:
Purchase Date:
www.firmangenerators.com
PORTABLE GENERATOR
NOTE:
[CAUTION]
WARNING
Do not operate the generator before you have read and understood the instructions.
Failure to do so could result in personal injury or equipment damage.
The generator is designed to give safe and dependable service if operated according
to instructions.
Indicates a strong possibility of severe personal injury, loss of life and equipment damage if
instructions are not followed.
Indicates a possibility of personal injury, or equipment damage if instructions are not followed.
Gives helpful information.
If a problem should arise, or if you have any questions about the generator, consult a dealer
selling FIRMAN generators.
Thank you for purchasing a FIRMAN generator.
This manual covers operation and maintenance of the FIRMAN generators. All information in this
publication is based on the latest production information available at the time of approval for
printing.
Pay special attention to statements preceded by the following words:
WARNING
Page 01
Safe Operation Checklist
Safe operation of the portable generator requires the completion of the following tasks:
Carbon Monoxide (CO) Alarm
Carbon monoxide (CO) alarm(s) in working order.
Smoke Alarm
Smoke alarm (s) in working order.
Generator Location
Generator placed in a Carbon Monoxide (CO) safe zone. See Generator Location to
reduce the Risk of Carbon Monoxide Poisoning.
Generator placed in a fire safe zone. See Generator Location to reduce the Risk of
Generator located on flat and level surface.
Oil and Fuel
Engine filled to proper oil level. See Add Engine Oil.
Fuel tank filled at or below baffle. See Add Fuel
.
Inspect fuel lines, tank, cap and fittings each time before using generator. DO NOT
use if fuel leak or damage is found.
Electrical
When connecting to a buildings electrical system, install listed transfer equipment.
See Connecting to a Building Electrical System.
Electrical cords are rated for intended loads. See Cord Sets and Receptacles.
Electrical cords do not run through doorways, windows, holes in ceilings, walls or
Inspect electrical cords thoroughly before each use. DO NOT use if damaged.
All labeled electrical cord safeties are understood and being followed.
Operation
Start engine. See Starting the Engine.
Fire.
floors.
Page 02
1. SAFETY PRECAUTIONS .................................................................................04
2. SPECIFICATIONS..........................................................................................08
3. COMPONENTS............................................................................................09
4. PRE-OPERATION CHECKS............................................................................10
5. OPERATING PROCEDURES...........................................................................13
6. SERVICING THE GENERATOR.......................................................................16
7. “HOW-TO” MAINTENANCE...........................................................................17
8. PREPARATION FOR STORAGE.......................................................................20
9. TROUBLE SHOOTING...................................................................................21
10. WARRANTY..................................................................................................22
Table of Contents
Page 03
1. SAFETY PRECAUTIONS
Page 04
WARNING
POISONOUS GAS HAZARD.
Engine exhaust contains carbon monoxide, a poisonous gas that could
kill you in minutes. You CANNOT smell it, see it, or taste it. Even if you do
not smell exhaust fumes, you could still be exposed to carbon monoxide
gas.
Operate this product ONLY outside far away from windows, doors and vents to reduce
the risk of carbon monoxide gas from accumulating and potentially being drawn
towards occupied spaces.
Install battery-operated carbon monoxide alarms or plug-in carbon monoxide alarms
with battery back-up according to the manufacturers instructions. Smoke alarms
cannot detect carbon monoxide gas.
DO NOT run this product inside homes, garages, basements, crawlspaces, sheds, or
other partially-enclosed spaces even if using fans or opening doors and windows for
ventilation. Carbon monoxide can quickly build up in these spaces and can linger for
hours, even after this product has shut off.
ALWAYS place this product downwind and point the engine exhaust away from
occupied spaces. If you start to feel sick, dizzy, or weak while using this product, shut
it off and get to fresh air RIGHT AWAY. See a doctor. You may have carbon monoxide
poisoning.
WARNING
Page 05
Starter cord kickback (rapid retraction) will pull hand and arm toward
engine faster than you can let go which could cause broken bones,
fractures, bruises, or sprains resulting in serious injury.
When starting engine, pull cord slowly until resistance is felt and then pull rapidly to
avoid kickback.
NEVER start or stop engine with electrical devices plugged in and turned on.
WARNING
Fuel and its vapors are extremely flammable and explosive
which could cause burns, fire, or explosion resulting in death
or serious injury.
WHEN ADDING OR DRAINING FUEL
Turn generator engine OFF and let it cool at least 2 minutes before removing fuel cap.
Loosen cap slowly to relieve pressure in tank.• Fill or drain fuel tank outdoors.
DO NOT overfill tank. Allow space for fuel expansion
If fuel spills, wait until it evaporates before starting engine.
Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.
Check fuel lines, tank, cap, and fittings frequently for cracks or leaks. Replace if
necessary.
DO NOT light a cigarette or smoke.
WHEN STARTING EQUIPMENT
Ensure spark plug, muffler, fuel cap, and air cleaner are in place.
DO NOT crank engine with spark plug removed.
WHEN OPERATING EQUIPMENT
DO NOT operate this product inside any building, carport, porch, mobile equipment,
marine applications, or enclosure.
DO NOT tip engine or equipment at angle which causes fuel to spill.
DO NOT stop engine by moving choke control to “Choke” position ( )
WHEN TRANSPORTING, MOVING OR REPAIRING EQUIPMENT
Transport/move/repair with fuel tank EMPTY or with fuel shutoff valve OFF.
DO NOT tip engine or equipment at angle which causes fuel to spill.
Disconnect spark plug wire.
WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK
Store away from furnaces, stoves, water heaters, clothes dryers, or other appliances
that have pilot light or other ignition source because they could ignite fuel vapors.
Page 06
WARNING
This generator does not meet U. S. Coast Guard Regulation 33CFR-183 and should not
be used on marine applications.
Failure to use the appropriate U. S. Coast Guard approved generator could result in
death or serious injury.
WARNING
Generator voltage could cause electrical shock or burn resulting in death
or serious injury.
Use listed transfer equipment, suitable for the intended use, to prevent backfeed by
isolating generator from electric utility workers.
When using generator for backup power, notify utility company.
Use a ground fault circuit interrupter (GFCI) in any damp or highly conductive area,
such as metal decking or steel work
DO NOT touch bare wires or receptacles.
DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise
damaged.
DO NOT operate generator in the rain or wet weather.
DO NOT handle generator or electrical cords while standing in water, while barefoot,
or while hands or feet are wet.
DO NOT allow unqualified persons or children to operate or service generator.
WARNING
Exhaust heat/gases could ignite combustibles, structures or
damage fuel tank causing a fire, resulting in death or serious
injury.
Contact with muffler area could cause burns resulting in
serious injury.
DO NOT touch hot parts and AVOID hot exhaust gases.
Allow equipment to cool before touching.
Keep at least 5 feet (1.5 m) of clearance on all sides of generator including overhead.
It is a violation of California Public Resource Code, Section 4442, to use or operate the
engine on any forest-covered, brush-covered, or grass-covered land unless the exhaust
system is equipped with a spark arrester, as defined in Section 4442, maintained in
effective working order. Other states or federal jurisdictions may have similar laws.
Contact the original equipment manufacturer, retailer, or dealer to obtain a spark
arrester designed for the exhaust system installed on this engine.
Replacement parts must be the same and installed in the same position as the original
parts.
Page 07
WARNING
Unintentional sparking could cause fire or electric shock resulting in death
or serious injury.
WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR
Disconnect the spark plug wire from the spark plug and place the wire where it cannot
contact spark plug.
WHEN TESTING FOR ENGINE SPARK
Use approved spark plug tester.
DO NOT check for spark with spark plug removed.
WARNING
Starter and other rotating parts could entangle hands, hair, clothing, or
accessories resulting in serious injury.
NEVER operate generator without protective housing or covers.
DO NOT wear loose clothing, jewelry or anything that could be caught in the starter
or other rotating parts.
Tie up long hair and remove jewelry.
[CAUTION]
Excessively high operating speeds could result in minor injury.
Excessively low operating speeds impose a heavy load.
DO NOT tamper with governor spring, links or other parts to increase engine speed.
Generator supplies correct rated frequency and voltage when running at governed speed.
DO NOT modify generator in any way.
NOTE:
DO NOT exceed the generators wattage/amperage capacity.
Start generator and let engine stabilize before connecting electrical loads.
Connect electrical loads in OFF position, then turn ON for operation.
Turn electrical loads OFF and disconnect from generator before stopping generator.
Use generator only for intended uses.
If you have questions about intended use, ask dealer or contact local service center.
Operate generator only on level surfaces.
DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.
DO NOT insert any objects through cooling slots.
If connected devices overheat, turn them off and disconnect them from generator.
Shut off generator if:
-electrical output is lost;
-equipment sparks, smokes, or emits flames;
-unit vibrates excessively.
120V
152F
57.2 lbs
17.3 X 14.1 X 13.9 in.
Rated AC Voltage
Phase
Power Factor
Engine Model
Engine Type
Voltage regulator
Generator
Model ECO 1500
1200Watts@60Hz
Capacity
Single Phase
1
Single Cylinder, 4-Stroke OHV Air Cooled
Displacement
Maximum output
Ignition System
Starting System
Fuel
Capacity Fuel Tank
79.8cc
Breakless Ignition Type, Flywheel Magneto
Unleaded Automotive Gasoline
Recoil
1.5 Gallon
13 oz
Lubricating Oil
Capacity
Counter Clockwise (Facing P.T.O.)
Float
Brushless
Polyurethane Type
Carburetor Type
Air Cleaner
Alternator Type
P.T.O. shaft rotation
Dime-
nsion
L X W X H
Dry Weight
Engine
Page 08
2.4HP
2 . SPECIFICATIONS
Running Watts
Starting Watts 1500Watts@60Hz
1. DC SOCKET
2. AC SOCKET
3. FUEL GAUGE
4. CIRCUIT BREAKER
5. FUEL TANK CAP
6. ENGINE SWITCH
7. FUEL VALVE
8. CHOKE LEVER
9. RECOIL STARTER
10. AIR CLEANER
11. OIL ALARM LAMP
12. OIL DRAIN PLUG
13. OIL FILLER CAP
14. GROUND TERMINAL
15. MUFFLER
16. FUEL TANK
17. SPARK ARRESTER
3. COMPONENTS
Page 09
1
2
3
4
5
6
7
8
9
10
1213
14
15
16
17
11
Page 10
4. PRE-OPERATION CHECKS
CHECK ENGINE OIL
Remove oil filter cap and check the engine
oil level.
Oil capacity:
Model................Upper level
ECO1500................13 oz
Change oil if contaminated. (See “HOW-TO”
MAINTENANCE)
If oil level is below the lower level line, refill
with suitable oil (see table below) to upper
level line. Do not screw in the oil filler cap
when checking oil level.
Multigrade
Ambient -20 -10
0
10
20
30
40
-4
14
32
50
68
86
104
5W
10W
20W
#20
#30
#40
10W-30
10W-40
Single grade
C
F
Before checking or refilling oil, be sure the
generator is put on a stable and level surface
with engine stopped.
temperature
Check fuel level at fuel gauge.
CHECKING COMPONENTS
Do not refuel while smoking or near open flame or other such potential fire hazards.
Otherwise a fire accident could occur.
If fuel level is low, refill with unleaded automotive gasoline.
Fuel tank capacity:
ECO1500........................1.5 Gallon
Make sure you review each warning in order to prevent fire hazard.
EMPTY
FULL
Fuel leakage from fuel hose etc. ,
Tighten any loose bolts or nuts.
Check components for damage or breakage.
Check following items before starting engine:
Do not refill tank while engine is running or hot.
Close fuel valve before refueling with fuel.
Be careful not to admit dust, dirt, water or other foreign objects into fuel
Wipe off spilt fuel thoroughly before starting engine.
Keep away from open flames.
Be sure to use the fuel filter screen on the fuel filter neck.
CHECK ENGINE FUEL
WARNING
Page 11
WARNING
Fuel must meet these requirements:
Clean, fresh, unleaded gasoline.
Octane rating of 86(R+M)/2 or higher.
Research Octane Number(RON)91
octane minimum.
Gasoline up to 10% ethyl alcohol,90%
unleaded is acceptable.
Methyl Tertiary Butyl Ether(MTBE) and
unleaded gasoline blend(max 15%
MTBE by volume)are approved.
Do not add oil to gasoline.
Do not overfill fuel tank.
Do not use gasoline older than 30 days.
NOTE: E15,E20 and E85 are NOT approved and should NOT be used, effects of old, stale
or contaminated fuel are not warrantable.
CHECKING GENERATOR SURROUNDINGS
Make sure you review each warning in order to prevent fire hazard.
Keep area clear of inflammables or other hazardous materials.
Keep generator at least 3 feet (1 meter) away from buildings or other structures.
Only operate generator in a dry, well ventilated area.
Keep exhaust pipe clear of foreign objects.
Keep generator away from open flame.
Keep generator on a stable and level surface.
Do not block generator air vents with paper or other material.
Page 12
WARNING
CHECKING GROUND TERMINAL
The ground terminal is used to assist in properly grounding the generator to help protect
against electrical shock. Consult with a local electrician for grounding requirements in
your area.
THERE IS A PERMANENT CONDUCTOR BETWEEN THE GENERATOR (STATOR WINDING)
AND THE FRAME.
Make sure the generator place flat on the ground.
Keep the generator at least 1 meter (3 feet) away
from any structure or building during use.
STARTING THE ENGINE
5. OPERATING PROCEDURES
(a) Check the AC circuit breaker. Make sure the
circuit breaker is in the ON position.
(b) Open the fuel switch to ON position.
(c)Set the choke lever to the "CHOKE
(arrow mark)position.
Not necessary if the engine is warm.
Page 13
(d) Turn the engine switch to the
ON” position.
ON
OFF
(e) Pull the starter handle slowly until
resistance is felt. This is the "Compression"
point.Return the handle to its original
position and pull swiftly. Do not fully pull
out the rope. After starting, allow the starter
return to its original position while still
holding the handle. If the engine fails to
start after several attempts, repeat above
procedures with choke lever returned
"CHOKE" position.
(f) Move the choke lever to the “Run” position.
Circuit Breaker
ON
OFF
USING ELECTRIC POWER
Be sure to ground the generator if the connected electrical equipment is grounded.
NOTE:
(a) Let the engine stabilize and warm up for a few minutes after starting
(b) Plug in and turn on the desired 120 Volt AC single phase, 60 Hz electrical loads.
When the circuit breaker or no-fuse breaker turns off during operation, the generator is
overloaded or the appliance is defective.
Stop the generator immediately, check the appliance and /or generator for overloading
or defect and repair as necessary.
Page 14
DO NOT connect 3-phase loads to the generator.
DO NOT connect 50 Hz loads to the generator.
Connecting a generator to your electric utility companys power lines or to another power
source may be against the law. In addition this action, if done incorrectly, could damage
your generator and appliances and could cause serious injury or even death to you or a
utility worker who may be working on nearby power lines. If you plan to run a portable
electric generator during an outage, please notify your electric utility company
immediately and remember to plug your appliances directly into the generator. Do not
plug the generator into any electric outlet in your home. Doing so could create a
connection to the utility company power lines. You are responsible for ensuring that your
generators electricity does not feed back into the electric utility power lines. If the
generator will be connected to a building electrical system, consult your local utility
company or a qualified electrician. Connections must isolate generator power from utility
power and must comply with all applicable laws and codes.
STOPPING THE GENERATOR
(a) Turn off and unplug all electrical loads. Never start
or stop the generator with electrical devices plugged
in or turned on.
(b) Let the generator run at no-load for several minutes
to stabilize internal temperatures of the engine and
generator.
( c) Turn the Fuel Valve to the “OFF” position.
(d) Let the engine run until fuel starvation has stopped
the engine. This usually takes a few minutes.
Page 15
ON
OFF
(e) Press the engine switch to the “OFF” position. ON
OFF
6. SERVICING THE GENERATOR
MAINTENANCE SCHEDULE
The electrical safety may only be checked by personnel authorized for this task.
SERVICING WORK
CHECKING ELECTRICAL SAFETY
● Check the air cleaner
● Check oil level and refill to the upper level before
starting the engine.
● Check all the points indicated in "PRE-OPERATION
CHECKS".
● Clean and wash air-cleaner element.
More often if used in dirty or dusty environments.
● Change engine oil.(The initial oil change must be
conducted after the 25 hours operation.)
● Check spark plug, and clean and adjust if necessary.
● Check and clean the fuel shut-off valve.
● Replace air-cleaner element.
○ Decarbonize cylinder head, valves and piston.
○ Check and replace carbon brushes.
● Replace spark plug.
○ Inspect control panel components.
○ Check rotor and stator.
300 hours or
every year
100 hours
50 hours(Weekly)
Daily
Servicing work should only be carried out by personnel qualified for this purpose.
All the works listed in the service plan are to be carried out in accordance with the
operating and service instructions for the motor.
We recommend that these works be carried out by an authorized service station.
NOTE:
Initial oil change should performed after first 5 hours of use. There after change oil every 50
hours. Before changing oil, check for a suitable way to dispose of the old oil. Do not pour it
down into sewage drains, onto garden soil or into open streams. Your local zoning
environmental regulations will give you more detailed instructions on proper disposal.
Items marked with a “O” required advanced skill and tools, so they should be done by the
distributor.
Page 16
7. "HOW-TO" MAINTENANCE
ENGINE OIL CHANGE
SERVICING THE AIR CLEANER
Change engine oil every 50 hours.
(for a new engine, change oil after 5 hours.)
(a) Drain oil by removing the drain plug and
the oil filler cap while the engine is warm.
Please use a container to dump the
used oil for protecting the environment.
(b) Reinstall the drain plug and fill the engine
with oil until it reaches the upper level on the
oil filler cap.
Use fresh and high quality lubricating oil to the specified quantity.
If contaminated or deteriorated oil is used or the quantity of the engine oil is not
sufficient, the engine damage will result and its life will be greatly shortened.
Always keep the element clean.
(a) Take out the air cleaner, clean it well
in kerosene and dry it.
(b) After wetting the element by clean
engine oil squeeze it tight by hand.
(c) Lastly, put the element in the case
and install it securely.
Maintaining an air cleaner in proper
condition is very important. Dirt induced
through improperly installed, improperly
serviced, or inadequate elements
damages and wears out engines.
Page 17
NOTE:
CLEANING AND ADJUSTING THE SPARK PLUG
CLEANING FUEL STRAINER
(a) If the plug is contaminated with carbon,
using a plug cleaner and wire brush.
(b) Adjust the electrode gap to 0.7 to
0.8 mm (0.028” to 0.031”).
SPARK PLUG: TORCH F6RTC equivalent.
Dirt and water in the fuel are removed
by the fuel strainer.
(a) Remove the strainer cup and throw
away water and dirt.
(b) Clean the screens and strainer cup
with gasoline.
(c) Tightly fasten the cup to main body,
making sure to avoid fuel leak.
Page 18
BODY
SCREEN 2
GASKET
CUP
SCREEN 1
Page 19
Inspect Muffler and Spark Arrester
Inspect the muffler for cracks, corrosion, or other damage. Remove the spark arrester, if
equipped, and inspect for damage or carbon blockage. If replacement parts are required,
make sure to use only original equipment replacement parts.
DO NOT touch hot parts and AVOID hot exhaust gases.
Allow equipment to cool before touching.
Replacement parts must be the same and installed in the same position as the original parts.
Exhaust heat/gases could ignite combustibles, structures or damage
fuel tank causing a fire, resulting in death or serious injury.
Contact with muffler area could cause burns resulting in serious injury.
Keep at least 5 feet (1.5 m) of clearance on all sides of generator including overhead.
Contact the original equipment manufacturer, retailer, or dealer to obtain a spark arrester
designed for the exhaust system installed on this engine.
Clean or replace spark arrester as follows:
WARNING
1. Allow the engine to cool completely before servicing the spark arrester.
2. Remove the two screws holding the cover plate which retains the end of the spark
arrester to the muffler.
3. Remove the spark arrester screen.
4. Carefully remove the carbon deposits from the spark arrester screen with a wire brush.
5. Replace the spark arrester if it is damaged.
6. Position the spark arrester in the muffler and attach with the two screws.
Failure to clean the spark arrester will result in degraded engine performance.
[CAUTION]
8. STORAGE
DRAIN
SCREW
Page 20
The generator should be started at least once every 14 days and allowed to run for at least
20 minutes. For longer term storage, please follow these guidelines.
1. Add a properly formulated fuel stabilizer to the tank.
2. Be sure all appliances are disconnected from the generator.
3. Run the generator for a few minutes so the treated fuel cycles through the fuel system
and carburetor.
4. Turn the fuel valve to the “Off” position.
5. Let the generator run until fuel starvation has stopped the engine. This usually takes a
few minutes.
6. The generator needs to cool completely before cleaning and storage.
7. Clean the generator according to the maintenance section.
8. Change the oil.
9. Remove the spark plug and pour about 12 ounce (14.8 ml) of oil into the cylinder.
Crank the engine slowly to distribute the oil and lubricate the cylinder.
10. Reattach the spark plug.
11. Store the unit in a clean, dry place out of direct sunlight.
Our engines work well with 10% or less ethanol blend fuels. When using blended fuels
there are some issues worth noting:
NOTE:
Ethanol-gasoline blends can absorb more water than gasoline alone.
These blends can eventually separate, leaving water or a watery goo in the tank, fuel
valve and carburetor.
With gravity-fed fuel supplies, this compromised fuel can be drawn into the carburetor
and cause damage to the engine and/or potential hazards.
There are only a few suppliers of fuel stabilizer that are formulated to work with ethanol
blend fuels.
Any damages or hazards caused by using improper fuel, improperly stored fuel, and/or
improperly formulated stabilizers, are not covered by manufactures warranty.
It is advisable to always shut off the fuel supply, run the engine to fuel starvation and
drain the tank when the equipment is not in use for more than 30 days.
9. TROUBLE SHOOTING
Page 21
Problem Cause Correction
Engine is running, but no
AC output is available.
1. Circuit breaker is open.
2. Fault in generator.
3. Poor connection or defective cord
set.
4. Connected device is bad.
1. Reset circuit breaker.
2. Contact authorized service facility.
3. Check and repair.
4. Connect another device that is in
good condition.
Engine runs good at
no-load butbogs down
when loads are connected.
1. Short circuit in a connected load.
2. Engine speed is too slow.
3. Generator is overloaded.
4. Shorted generator circuit.
1. Disconnect shorted electrical load.
2. Contact authorized service facility.
3. See Don't Overload Generator
4. Contact authorized service facility.
Engine will not start; starts
and runs rough or shuts
down when running.
1. Engine switch set to OFF (0)
position.
2. Fuel shutoff lever is in OFF (0)
position.
3. Low oil level.
4. Dirty air cleaner.
5. Out of fuel.
6. Stale fuel.
7. Spark plug wire not connected to
spark plug.
8. Bad spark plug.
9. Water in fuel.
10. Flooded.
11. Excessively rich fuel mixture.
12. Intake valve stuck open or closed.
13. Engine has lost compression.
1. Set engine switch to ON (I)
position.
2. Move fuel shutoff lever to ON (I)
position.
3. Fill crankcase to proper level or
place generator on level surface.
4. Clean or replace air cleaner.
5. Fill fuel tank.
6. Drain fuel tank and carburetor; fill
with fresh fuel.
7. Connect wire to spark plug.
8. Replace spark plug.
9. Drain gas tank and carburetor; fill
with fresh fuel.
10. Wait 5 minutes and re-crank engine.
11. Contact authorized service facility.
12. Contact authorized service facility.
13. Contact authorized service facility.
Engine lacks power.1. Load is too high.
2. Dirty air filter.
1. Don't Overload Generator
2. Replace air filter.
Enginehuntsor falters.
Carburetor is running too rich or too Contact authorized service facility.
lean.
Page 22
Warranty Qualifications
Firman generator will register the warranty upon receipt of your Warranty
Registration Card and a copy of your sales receipt from one of FIRMANs retail locations
as proof of purchase. Please submit your warranty registration and your proof of purchase
within ten (10) days of the date of purchase.
Repair/Replacement Warranty
Firman warrants to the original purchaser that the mechanical and electrical
components will be free of defects in material and workmanship for a period of one (1)
year (parts and labor) and two (2) years (parts) from the original date of purchase (90
days [parts and labor] and 180 days [parts] for commercial & industrial use. Transportation
charges on product submitted for repair or replacement under this warranty are the sole
responsibility of the purchaser. This warranty only applies to the original purchaser and
is not transferable.
Do Not Return the Unit to the Place of Purchase
Contact FIRMAN Service Center and FIRMAN will troubleshoot any issue via phone or
e-mail. If the problem is not corrected by this method, FIRMAN will, at its option, authorize
evaluation, repair or replacement of the defective part or component at a FIRMAN Service
Center. FIRMAN will provide you with a case number for warranty service. Please keep it
for future reference. Repairs or replacements without prior authorization, or at an
unauthorized repair facility, will not be covered by this warranty.
Warranty Exclusions
This warranty does not cover the following repairs and equipment:
Normal Wear
Your product needs periodic parts and service to perform well. This warranty does not
cover repair when normal use has exhausted the life of a part or the equipment as a whole.
Installation, Use and Maintenance
This warranty will not apply to parts and/or labor if your product is deemed to have been
misused, neglected, involved in an accident, abused, loaded beyond the generators
limits, modified, installed improperly or connected incorrectly to any electrical component.
Normal maintenance is not covered by this warranty.
Other Exclusions
This warranty excludes:
– cosmetic defects such as paint, decals, etc.,
– wear items,
– accessory parts,
– failures to due acts of God and other force majeure events beyond the manufacturers
control,
problems caused by parts that are not original FIRMAN parts.
10.FIRMAN Two (2) Year Limited Warranty
Page 23
Limits of Implied Warranty and Consequential Damage
FIRMAN disclaims any obligation to cover any loss of time, use of this product, freight,
or any incidental or consequential claim by anyone from using this product. THIS
WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE.
A unit provided as an exchange will be subject to the warranty of the original unit. The
length of the warranty governing the exchanged unit will remain calculated by reference
to the purchase date of the original unit.
This warranty gives you certain legal rights which may change from state to state. Your
state may also have other rights you may be entitled to that are not listed within this
warranty.
Contact Information
You may contact FIRMAN at:
Address
SUMEC North America
Attn: Customer Service
2090 Baker Road Suite 304 Box 105
Kennesaw Ga. 30144
www.firmangenerators.com
Customer Service
Mon-Fri 8:30 AM- 5:30 PM (EST)
Toll Free:1-844-FIRMAN1(1-844-347-6261)
WWW.FIRMANGENERATORS.COM
Toll Free:1-844-347-6261
P/N:331535000 Rev 00
Serie Premium
EC01500
MANUAL DEL PROPIETARIO
®
IMPORTANTE: Lea detenidamente todas las instrucciones y precauciones
de seguridad antes de operar el equipo.
Cerciórese de que el motor esté detenido y nivelado antes de realizar
cualquier tarea de mantenimiento o reparaciones.
Anote la información del producto para usarla al solicitar piezas y obtener
cobertura para la garantía.
Especificación:
Número de serie:
Fecha de compra:
www.firmangenerators.com
GENERADOR PORTÁTIL
NOTA:
[PRECAUCIÓN]
ADVERTENCIA
Sólo opere el generador tras haber leído y comprendido las instrucciones, ya que de lo
contrario podrían producirse lesiones personales o daños al equipo.
El generador se ha diseñado para proporcionar un servicio seguro y fiable si se opera conforme
a las instrucciones.
Indica una gran posibilidad de lesiones personales graves, peligro de muerte y daños al equipo
si no se acatan las instrucciones.
Indica una posibilidad de lesiones personales o daños al equipo si no se acatan las instrucciones.
Proporciona información útil.
Si surgiera un problema o si tuviera alguna pregunta sobre el generador, consulte a un
distribuidor de generadores FIRMAN.
Gracias por comprar un generador FIRMAN.
Este manual cubre la operación y mantenimiento de los generadores FIRMAN. Toda la
información en esta publicación se basa en los datos de producción más recientes disponibles
al momento de aprobarse la impresión.
Preste especial atención a las declaraciones que comienzan con las siguientes palabras:
Page 01
ADVERTENCIA
Lista de verificación para la operación segura
Para brindar una operación segura del generador portátil se deben realizar las siguientes
tareas:
Alarma de monóxido de carbono (CO)
Alarma(s) de monóxido de carbono (CO) en funcionamiento.
Detector de humo
Detector(es) de humo en funcionamiento.
Ubicación del generador
El generador se encuentra en una superficie plana y nivelada.
Aceite y combustible
El motor tiene el nivel adecuado de aceite. Vea la sección sobre cómo añadir aceite al motor.
El tanque de combustible se ha llenado a nivel o debajo del deflector. Vea la sección sobre
cómo añadir combustible.
.
Consideraciones eléctricas
Operación
Poner en marcha el motor. Vea la sección sobre cómo arrancar el motor.
Page 02
El generador se encuentra en una zona segura contra monóxido de carbono
(CO). Vea la sección sobre la ubicación del generador para reducir el riesgo
de envenenamiento por monóxido de carbono.
El generador se encuentra en una zona segura contra incendios. Vea la sección
sobre la ubicación del generador para reducir el riesgo de incendios.
Siempre revise las tuberías, tanque, tapa y acoples del sistema de combustible
antes de utilizar el generador. NO o utilice si hay una fuga de combustible o
detecta daños.
Cuando conecte la unidad al sistema eléctrico de un inmueble, instale el equipo
de transferencia indicado. Vea la sección sobre conexión al sistema eléctrico de
un inmueble.
Los cables eléctricos están diseñados para las cargas previstas. Vea la sección de
conjuntos de cables y tomacorrientes.
Los cables eléctricos no deben tenderse a través de puertas de entradas,
ventanas, agujeros en cielos rasos, paredes ni pisos.
Revise completamente los cables eléctricos antes de cada uso. NO los utilice
si están dañados.
Ha comprendido y acatado todos los rótulos de seguridad sobre cables eléctricos.
1. PRECAUCIONES DE SEGURIDAD .................................................................................04
2. ESPECIFICACIONES..........................................................................................08
3. COMPONENTES...........................................................................................09
4. REVISIONES PREVIAS A LA OPERACIÓN...........................................................................10
5. PROCEDIMIENTOS DE OPERACN........................................................................13
6. REPARAR EL GENERADOR.......................................................................16
7. PROCEDIMIENTOS DE MANTENIMIENTO....................................................................17
8. PREPARACIÓN PARA EL ALMACENAMIENTO...........................................................20
9. RESOLUCIÓN DE PROBLEMAS...................................................................................21
10.GARANTÍA................................................................................................22
Contenido
Page 03
1. PRECAUCIONES DE SEGURIDAD
Page 04
PELIGRO DE GAS VENENOSO.
El escape del motor contiene monóxido de carbono, un gas venenoso que
podría provocar la muerte en cuestión de minutos. NO TIENE olor, sabor
y es invisible. Incluso si usted no huele los humos de escape, de todas
maneras podría exponerse al gas del monóxido de carbono.
SÓLO opere este producto en exteriores lejos de ventanas, puertas y conductos para
reducir el riesgo de acumulación de monóxido de carbono y la potencial propagación
de este gas hacia espacios habitados.
Instale alarmas de monóxido de carbono que operen o se respalden con pilas conforme
a las instrucciones del fabricante. Los detectores de humo no pueden identificar el gas
del monóxido de carbono.
NO haga funcionar este producto dentro de la casa, garajes, sótanos, entresuelos,
entretechos, galpones ni en otros espacios parcialmente cerrados, incluso si hay
ventiladores o las puertas y ventanas están abiertas para su ventilación. El monóxido
de carbono puede acumularse rápidamente en tales lugares y puede permanecer
por horas, incluso tras haber apagado este producto.
SIEMPRE coloque este producto a favor del viento y apunte el escape del motor en
dirección opuesta a los espacios habitados. Si comienza a sentirse mal, mareado o
débil mientras usa este producto, apáguelo y procure respirar aire fresco INMEDIATAMENTE.
Vea a un doctor. Puede estar sufriendo envenenamiento por monóxido de carbono.
PELIGRO
Utilizar un generador en interiores PUEDE PROVOCAR LA
MUERTE EN CUESTIÓN DE MINUTOS.
Los gases del generador contienen monóxido de carbono, el cual
es una sustancia venenosa que no puede verse ni olerse.
NUNCA lo utilice dentro de la
casa o garaje, INCLUSO SI están
abiertas las puertas y ventanas.
Sólo úselo EN EXTERIORES
bien alejado de ventanas,
puertas y conductos.
ADVERTENCIA
Page 05
El retroceso del cable del arrancador (retracción rápida) puede jalar hacia
el motor las manos y brazos atrapándolos rápidamente, lo cual podría causar
lesiones graves debido a fracturas, hematomas o esguinces.
Al poner en marcha el motor, jale el cable lentamente hasta que sienta cierta resistencia
y luego jálelo rápidamente para evitar que se retraiga de un golpe.
NUNCA arranque o detenga el motor si están enchufados y encendidos aparatos eléctricos.
El combustible y sus vapores son sumamente inflamables y
explosivos, lo cual podría provocar lesiones graves o la muerte
debido a quemaduras, incendios o explosiones.
AL AÑADIR O DRENAR COMBUSTIBLE
Apague el motor del generador y déjelo enfriar al menos 2 minutos antes de retirar la
tapa de combustible. Afloje la tapa lentamente para liberar la presión en el tanque.
Llene o drene el tanque de combustible en exteriores.
NO llene el tanque excesivamente. Deje espacio para que se expanda el combustible.
Si se derrama combustible, espere hasta que se evapore antes de poner en marcha el motor.
Mantenga el combustible lejos de chispas, llamas expuestas, llamas piloto, calor y otras
fuentes de ignición.
Revise frecuentemente las tuberías, tanque, tapa y acoples del sistema de combustible
para constatar si presentan grietas o fugas. Reemplace todo componente que lo amerite.
NO encienda cigarrillos ni fume.
AL PONER EL EQUIPO EN MARCHA
Cerciórese de que estén instalados correctamente la bujía, silenciador, tapa de combustible
y depuradores de aire.
NO haga partir el motor si no está instalada la bujía.
AL OPERAR EL EQUIPO
NO opere este producto dentro de ningún inmueble, cobertizo para automóviles, porche,
equipamiento móvil, aplicaciones marítimas o recintos cerrados.
NO incline el motor o equipamiento con un ángulo que podría derramar el combustible.
NO detenga el motor moviendo el control del cebador a la posición de obstrucción “Choke” ( )
AL TRANSPORTAR, MOVER O REPARAR EL EQUIPO
Transporte/mueva/repare el equipo con el tanque de combustible VACÍO o con la válvula de
corte APAGADA.
NO incline el motor o equipamiento con un ángulo que podría derramar el combustible.
Desconecte el cable de la bujía.
AL ALMACENAR COMBUSTIBLE O EQUIPAMIENTO CON GASOLINA EN EL TANQUE
Almacénelo lejos de calderas, estufas, calentadores de agua, secadoras de ropa u otros
artefactos que tengan llama piloto u otras fuentes de ignición ya que estos podrían inflamar
los vapores del combustible.
ADVERTENCIA
ADVERTENCIA
Page 06
Este generador no cumple la normativa 33CFR-183 de la Guardia Costera de EE. UU. y
no debe utilizarse en aplicaciones marítimas.
Si no utiliza un generador aprobado por la Guardia Costera de EE. UU. podrían producirse
lesiones graves o la muerte.
El voltaje del generador podría provocar lesiones graves o la muerte debido
a descargas eléctricas o quemaduras.
Utilice el equipo de transferencia indicado, apto para el uso previsto, a fin de prevenir
el retorno de energía al aislar el generador de los trabajadores de la empresa eléctrica.
Notifique a la empresa de electricidad cuando utilice el generador como fuente de
respaldo de energía.Utilice un interruptor de circuito de fallos con conexión a tierra
(GFCI) en toda área húmeda o altamente conductiva, como plataformas metálicas o
estructuras de acero.
NO toque tomacorrientes o cables expuestos
NO utilice el generador con cables eléctricos que estén deteriorados, deshilachados,
al descubierto o dañados de alguna forma.
NO opere el generador en condiciones de lluvia o humedad.
NO manipule el generador ni cables eléctricos si está parado sobre agua, si está descalzo
o si sus manos o pies están mojados.
NO permita que nos o personas no calificadas operen o den mantenimiento al generador.
Los gases/calor del escape podrían inflamar materiales
combustibles, quemar estructuras o dañar el tanque de
combustible produciendo incendios que pueden causar la
muerte o lesiones graves.
El contacto con el área del silenciador puede provocar graves
lesiones debido a quemaduras.
NO toque las partes calientes y EVITE la exposición a gases calientes del escape.
Deje enfriar el equipo antes de tocarlo.
Mantenga un espacio de al menos 1,5 metros (5 pies) en todos los lados del generador,
incluso por encima.
Constituye una infracción al Código de recursos públicos de California, Sección 4442,
utilizar u operar el motor en cualquier terreno cubierto de árboles, arbustos o césped,
a menos que el sistema de escape esequipado con un parachispas (según lo establecido
en la Sección 4442) que se encuentre en perfecto estado de funcionamiento. Puede que
otras jurisdicciones estatales o federales mantengan una legislación similar al respecto.
Comuquese con el fabricante de equipo original, tienda minorista o distribuidor para
obtener un parachispas apto para el sistema de escape instalado en este motor.
Se deben utilizar piezas de recambio idénticas e instalarse en la misma posición de las
originales.
ADVERTENCIA
ADVERTENCIA
ADVERTENCIA
Page 07
Las chispas accidentales podrían provocar lesiones graves o la muerte
debido a incendios o descargas eléctricas.
AL REALIZAR AJUSTES O REPARACIONES AL GENERADOR
Desconecte el cable de la bujía y colóquelo en un lugar que no entre en contacto con la bujía.
AL PROBAR EL ENCENDIDO DEL MOTOR
Utilice un probador de bujías autorizado.
NO verifique el encendido si no está instalada la bujía.
El arrancador y otras piezas giratorias podrían atrapar las manos, cabello,
ropa o accesorios personales provocando graves lesiones.
NUNCA opere el generador si no están instaladas las cubiertas o carcasa protectora.
NO use ropa holgada, joyas ni otras prendas que podrían quedar atrapadas en el
arrancador u otras piezas giratorias.
Ate el cabello largo y quítese las joyas.
[PRECAUCIÓN]
Las velocidades de funcionamiento excesivamente altas podrían provocar lesiones leves.
Las velocidades de funcionamiento excesivamente bajas hacen trabajar demasiado al generador.
NO altere la unidad con resortes reguladores, empalmes ni otras piezas para aumentar la
velocidad del motor. El generador suministra la frecuencia nominal y voltaje correctos
cuando funciona a la velocidad establecida.
NO modifique el generador de manera alguna.
NOTA:
NO exceda la capacidad de amperaje/vatiaje del generador.
Ponga en marcha el generador y deje que el motor se estabilice antes de conectar las
cargas eléctricas.
Conecte las cargas eléctricas en la posición OFF (apagado), y luego enciéndalas.
Apague las cargas eléctricas y desconéctelas del generador antes de detenerlo.
Sólo utilice el generador para los usos previstos.
Si tiene alguna pregunta sobre el uso previsto, consulte al distribuidor o comuníquese
con el centro de servicio de su localidad.
Sólo opere el generador en superficies niveladas.
NO exponga el generador a humedad excesiva, polvo, suciedad o vapores corrosivos.
NO introduzca ningún tipo de objeto en las ranuras de enfriamiento.
Si se sobrecalientan los dispositivos conectados, apáguelos y desconéctelos del generador.
Apague el generador si:
-se corta la generación eléctrica;
-el equipo emite chispas, humos o llamas;
-la unidad vibra excesivamente.
ADVERTENCIA
ADVERTENCIA
120V
Tensión nominal de CA
Fase
Factor de potencia
Modelo de motor
Tipo de motor
Regulador de voltaje
Generador
Modelo ECO 1500
1200 vatios a 60 Hz
Condensador
Monofásico
1
Monocilíndrico, 4 tiempos, OHV (válvulas en la culata), enfriado por aire
Cilindrada
Potencia máxima
Sistema de encendido
Sistema de arranque
Combustible
Capacidad del tanque
de combustible
79.8cc
Encendido electrónico, volante magnético
Gasolina automotriz sin plomo
Retroceso
1.5 gal
13 oz
Capacidad del aceite
lubricante
Antihorario (apuntando hacia la toma de fuerza)
Flotador
Sin
Tipo de poliuretano
Tipo de carburador
Depurador de aire
Tipo de alternador
Rotación del eje de
la toma de fuerza
Dimensión
Lar X Anc X Alt
Peso en seco
Motor
Page 08
2.4HP
2 . ESPECIFICACIONES
Vatios de funcionamiento
Vatios de arranque 1500 vatios a 60 Hz
152F
57.2 lbs
17.3 X 14.1 X 13.9 pulg
escobillas
3. COMPONENTS
Page 09
1. DC ENCHUFE HEMBRA
2. AC ENCHUFE HEMBRA
3. INDICADOR DE COMBUSTIBLE
4. DISYUNTOR
5. TAPA DEL TANQUE DE COMBUSTIBLE
6. INTERRUPTOR DEL MOTOR
7. VÁLVULA DE COMBUSTIBLE
8. PALANCA DEL CEBADOR
9. ARRANQUE DE RETROCESO
10. DEPURADOR DE AIRE
11. LA ALARMA DE LA LÁMPARA
DE ACEITE DE MOTOR
12. TAPÓN DEL VACIADO DE ACEITE
13. TAPA DE RELLENO DE ACEITE
14. TERMINAL A TIERRA
15. SILENCIADOR
16. TANQUE DE COMBUSTIBLE
17.LOS PARARRAYOS DE LA CHISPA
1
2
3
4
5
6
7
8
9
10
1213
14
15
16
17
11
REVISAR EL ACEITE DEL MOTOR
TAPA DE RELLENO DE ACEITE
(INDICADOR DE ACEITE)
NIVEL SUPERIOR
NIVEL INFERIOR
Retire la tapa de relleno de aceite y revise el
nivel de aceite del motor.
Capacidad del aceite:
Modelo................Nivel superior
ECO1500.............13 oz líq
Cambie el aceite si está contaminado. (Vea los
PROCEDIMIENTOS DE MANTENIMIENTO)
Si el nivel de aceite se encuentra debajo de la
línea inferior, llene con aceite adecuado
(vea la tabla abajo) hasta la línea superior.
No atornille la tapa de relleno de aceite cuando
esté revisando el nivel.
Multigrado
-20 -10
0
10
20
30
40
-4
14
32
50
68
86
104
5W
10W
20W
Nº20
Nº30
Nº40
10W-30
10W-40
Monogrado
C
F
Page 10
Antes de revisar o llenar el aceite, cerciórese de
colocar el generador en una superficie estable y
nivelada con el motor detenido.
Temperatura ambiente
Revise el nivel de gasolina en el indicador de combustible.
REVISAR COMPONENTES
No llene combustible mientras esté fumando o se encuentre cerca de una llama abierta u otro
potencial peligro de inflamación, ya que podría producirse un incendio accidental.
Si el nivel está bajo, llene con gasolina
automotriz sin plomo.
Capacidad del tanque de combustible:
ECO1500.............1.5 gal
Cerciórese de revisar cada una de las advertencias a fin de prevenir peligros de incendio.
LLENO VACÍO
Derrames de gasolina en la manguera del sistema de combustible, etc.
Apriete todos los pernos o tuercas que estén aflojados.
Revise si hay componentes dañados o quebrados.
Revise lo siguiente antes de poner en marcha el motor:
No llene el tanque mientras el motor esté en marcha o caliente.
Cierre la palanca de combustible antes de recargar gasolina.
Cerciórese de que no entre polvo, suciedad, agua ni otros objetos extraños en la gasolina
Limpie la gasolina derramada completamente antes de poner en marcha el motor.
Mantenga el generador lejos de llamas abiertas.
Cerciórese de usar la rejilla del filtro de
combustible en el cuello del filtro.
REVISAR EL COMBUSTIBLE DEL MOTOR
Page 11
El combustible debe cumplir los
siguientes requisitos:
Gasolina limpia, reciente, sin plomo.
Octanaje de 86(R+M)/2 o superior.
91 octanos RON como mínimo.
Gasolina hasta con un 10% de alcohol
etílico, 90% sin plomo es aceptable.
Se acepta mezcla de éter metil tert-
butílico (MTBE) y gasolina sin plomo
(máx 15% de MTBE por volumen).
No añada aceite a la gasolina.
No llene el tanque excesivamente.
No utilice gasolina almacenada por más de 30 días.
NOTA: NO se aprueban ni deben usarse mezclas E15, E20 ni E85; no se garantizan
resultados óptimos con combustible antiguo, rancio o contaminado.
ADVERTENCIA
ADVERTENCIA
REVISAR LAS INMEDIACIONES DEL GENERADOR
Cerciórese de revisar cada una de las advertencias a fin de prevenir peligros de incendio.
Mantenga el área libre de materiales peligrosos o inflamables.
Mantenga el generador a una distancia mínima de 1 metro (3 pies) de inmuebles u
otras estructuras.
Sólo opere el generador en áreas secas y bien ventiladas
Mantenga el tubo de escape libre de objetos extraños.
Mantenga el generador lejos de llamas abiertas.
Mantenga el generador en una superficie estable y nivelada.
No obstruya los conductos de ventilación del generador con papel ni otro tipo de materiales.
Page 12
Asegúrese de que el lugar está colocado plano en el suelo.
Mantenga el generador a al menos 1 metro (3 pies) de
distancia de cualquier estructura o edificio durante su uso.
REVISAR EL TERMINAL A TIERRA
El terminal a tierra se utiliza para conectar debidamente a tierra el generador a fin de
protegerlo contra descargas eléctricas. Consulte a un electricista de su localidad para
informase sobre los requisitos de conexión a tierra de su área.
EXISTE UN CONDUCTOR PERMANENTE ENTRE EL GENERADOR (BOBINADO DEL INDUCTOR)
Y EL ARMAZÓN.
ADVERTENCIA
ARRANCAR EL MOTOR
5. PROCEDIMIENTOS DE OPERACIÓN
(a) Compruebe el cortacircuitos de CA. Asegúrese
de que el cortacircuitos está en la posición de ON.
(b) Abra el interruptor de combustible en la
posición ON.
(c)Ajuste la palanca del estrangulador a la
posición "CHOKE" (marca de flecha).
No es necesario si el motor está caliente.
Page 13
(d) Ajuste el interruptor del motor a la posición
"ON".
(e) Tire de la manija del motor de arranque
lentamente hasta que se sienta resistencia. Este es
el punto de "Compresión". Devuelva la manija a su
posición original y tire rápidamente. No tire de la
cuerda completamente. Tras arrancar, deje que el
motor de arranque vuelta a su posición original
mientras sigue sujetando la manija. Si el motor no
arranca tras varios intentos, repita los procedimientos
anteriores devolviendo la palanca de estrangulamiento
a la posición "CHOKE".
(f) Mueva la palanca de estrangulamiento a la posición "Run".
ON
OFF
ON
OFF
Circuit Breaker
USANDO POTENCIA ELÉCTRICA
(a) D eje que el motor se estabilice y caliente durante unos minutos tras el arranque.
(b) E nchufe y encienda las cargas eléctricas de 60 Hz, 120 voltios de CA monofásicas deseadas.
Page 14
NOTA:
Asegúrese de poner a tierra el generador si el equipo eléctrico está puesto a tierra.
Cuando el cortacircuitos o el automático sin fusibles se desconecten durante la operación,
el generador está sobrecargado o el aparato es defectuoso.
Detenga el generador inmediatamente, compruebe el aparato y/o generador para ver si
hay una sobrecarga o defecto, y repárelo si es necesario.
NO CONECTE cargas trifásicas al generador.
NO CONECTE cargas de 50 Hz al generador.
Conectar un generador al tendido de su empresa de electricidad o a otra fuente de energía
puede ir en contra de la ley. Además de esta acción, si se hace incorrectamente, podría
dañar el generador y los aparatos, y podría ocasionar lesiones graves o incluso la muerte
a usted o a un trabajador de la compañía de servicios que pueda estar trabajando en las
líneas eléctricas cercanas. Si activa un generador eléctrico portátil durante un apagón,
por favor notifique a su compañía eléctrica inmediatamente y recuerde enchufar los
dispositivos directamente al generador. No enchufe el generador en cualquier toma
eléctrica de su hogar. Si lo hace, podría crear una conexión con las líneas de energía de
la empresa de servicios públicos. Usted es responsable de asegurar que la electricidad
del generador alimente a las líneas eléctricas de los servicios eléctricos. Si el generador
se conecta al sistema eléctrico de un edificio, consulte a la compañía local de servicios
públicos o a un electricista cualificado. Las conexiones deben aislar la alimentación del
generador de la energía de la red y deben cumplir con todas las leyes y códigos aplicables.
DETENER EL GENERADOR
( a) Apague y desenchufe todas las cargas eléctricas.
Nunca arranque o detenga el generador cuando los
dispositivos eléctricos estén conectados o encendidos.
(b) Deje que el generador funcione en vacío durante
varios minutos para estabilizar las temperaturas internas
del motor y el generador.
( c) Ajuste la válvula de combustible a la posición "OFF".
(d) Deje que el motor funcione hasta que el agotamiento
de combustible detenga el motor. Esto lleva normalmente
unos pocos minutos.
Page 15
ON
OFF
ON
OFF
(e) Pulse el interruptor del motor a la posición "OFF".
6. REPARAR EL GENERADOR
CALENDARIO DE MANTENIMIENTO
Los aspectos de seguridad eléctrica sólo deben estar a cargo de personal autorizado para dicha tarea.
FAENAS DE REPARACIÓN
REVISAR LA SEGURIDAD ELÉCTRICA
3 años
● Revise el depurador de aire.
● Revise el nivel de aceite y llénelo hasta el nivel superior
antes de poner en marcha el motor.
● Revise todos los puntos indicados en "REVISIONES
PREVIAS A LA OPERACIÓN"
● Limpie y lave el elemento del depurador de aire.
Con mayor frecuencia si la unidad se utiliza en entornos
sucios o polvorientos.
● Cambie el aceite del motor. (El recambio inicial debe
efectuarse después de 25 horas de funcionamiento).
● Revise la bujía, y límpiela y ajústela si fuera necesario.
● Revise y limpie la válvula de corte de combustible.
● Reemplace el elemento del depurador.
○ Descarbure las válvulas, pistón y culata del cilindro.
○ Revise y reemplace las escobillas de carbón.
● Reemplace la bujía.
○ Inspeccione los componentes del panel de control.
○ Revise el rotor y el inductor.
○ Reemplace la goma de montaje del motor.
○ Ponga a punto el motor.
● Cambie las tuberías del sistema de combustible.
300 horas o
anualmente
100 horas
50 horas
(semanalmente)
Periódicamente
Las faenas de reparación sólo deben efectuarse por personal calificado para tales tareas. Todas
las faenas indicadas en el plan de reparación deben realizarse en conformidad con las instrucciones
de funcionamiento y mantenimiento del motor.
Recomendamos efectuar tales tareas en un centro de servicio autorizado.
NOTA:
El recambio de aceite inicial debe efectuarse después de las primeras 5 horas de uso.
Posteriormente, cambie el aceite cada 50 horas. Antes de cambiar el aceite, busque una manera
adecuada de desechar el aceite antiguo. No lo vierta en los sistemas de alcantarillado, en tierra
de jardín ni en arroyos. Consulte las normas medioambientales de su localidad para obtener
mayor información sobre cómo desechar debidamente el aceite. Los puntos identificados con
un símbolo “O” requieren herramientas y conocimientos avanzados, por lo cual deben ser
efectuados por el distribuidor.
Page 16
7. PROCEDIMIENTOS DE MANTENIMIENTO
CAMBIO DE ACEITE DEL MOTOR
REPARAR EL DEPURADOR DE AIRE
ARRIBA
Cambie el aceite del motor cada 50 horas.
(cámbielo después de 5 horas si se trata de un
motor nuevo).
(a) Drene el aceite retirando el tapón de vaciado y la
tapa de relleno de aceite mientras el motor esté tibio.
Utilice un recipiente para vaciar el aceite antiguo a
fin de proteger el medio ambiente.
(b) Vuelva a instalar el tapón de vaciado y llene el
motor con aceite hasta que alcance el nivel superior
en la tapa de relleno.
Utilice aceite lubricante fresco y de alta calidad según la cantidad especificada.
Si se utiliza aceite contaminado o deteriorado, o si la cantidad de aceite no es suficiente,
el motor se dañará y se reducirá considerablemente su vida útil.
Siempre mantenga el filtro limpio.
(a) Extraiga el depurador de aire, límpielo bien con
queroseno y séquelo.
(b) Después de humedecer el filtro con aceite de
motor limpio, apriételo bien con la mano.
(c) Finalmente, coloque el filtro en su cubierta e
instálelo firmemente.
Mantener un depurador de aire en buenas condiciones
es sumamente importante. La suciedad inducida a
través de los elementos instalados o reparados
incorrectamente, así como los componentes
incorrectos, ocasionará daños y desgaste en el motor.
Page 17
NOTA:
LIMPIAR Y AJUSTAR LA BUJÍA
LIMPIAR EL COLADOR
(a) Si la bujía está contaminada con carbón,
utilice un limpiador de bujías o un cepillo de
alambre.
(b) Ajuste la separación de electrodos en 0,7
a 0,8 mm (0,028” a 0,031”).
BUJÍA: Equivalente a TORCH F6RTC.
El colador de combustible permite eliminar la
suciedad y agua.
(a) Retire la copa del colador y elimine el agua y
suciedad.
(b) Limpie con gasolina las rejillas y la copa del
colador.
(c) Apriete firmemente la copa al cuerpo principal,
cerciorándose de no derramar combustible.
Page 18
CUERPO
REJILLA 2
JUNTA
COPA
REJILLA 1
SEPARACN
DE ELECTRODOS
0,7 A 0,8 mm
(0,028A 0,031”)
Page 19
Inspeccionar silenciador y parachispas
Inspeccione que no haya grietas, corrosión ni otros daños en el silenciador. Retire el
parachispas, si está provisto, y revise que no presente daños ni que esté obstruido con
carbón. Si se requieren piezas de recambio, cerciórese de utilizar únicamente repuestos
originales.
NO toque las partes calientes y EVITE la exposición a gases calientes del escape.
Deje enfriar el equipo antes de tocarlo.
Se deben utilizar piezas de recambio idénticas e instalarse en la misma posición de las originales.
Los gases/calor del escape podrían inflamar materiales combustibles,
quemar estructuras o dañar el tanque de combustible produciendo
incendios que pueden causar la muerte o lesiones graves.
El contacto con el área del silenciador puede provocar graves lesiones
debido a quemaduras.
Mantenga un espacio de al menos 1,5 metros (5 pies) en todos los lados del generador, incluso
por encima.
Comuníquese con el fabricante de equipo original, tienda minorista o distribuidor para obtener
un parachispas apto para el sistema de escape instalado en este motor.
Limpie o reemplace el parachispas de la siguiente manera:
ADVERTENCIA
1. Deje que el motor se enfríe completamente antes de iniciar el apagachispas.
2 . Aparte los dos tornillos que sujetan la placa de cobertura que retiene el
extremo del apagachispas pegado al silenciador.
3 . Aparte la pantalla del apagachispas.
4 . Aparte con cuidado los depósitos de carbono de la pantalla del apagachispas
con un cepillo de alambre.
5 . Sustituya el apagachispas si está dañado.
6 . Coloque el apagachispas en el silenciador y acóplelo con los dos tornillos.
[PRECAUCIÓN]
El no limpiar el apagachispas provocará un empeoramiento del rendimiento del
motor.
8. ALMACENAMIENTO
El generador deberá ser arrancado al menos una vez cada 14 días y permitir que funcione
durante al menos 20 minutos. Para un almacenaje más a largo plazo, por favor siga estas
directrices.
1. Añada un estabilizador de combustible correctamente formulado al tanque.
2 . Asegúrese de que todos los dispositivos están desconectados del generador.
3 . Ponga en marcha el generador durante unos minutos para que el combustible tratado cicle
a través del sistema del combustible y el carburador.
4 . Desconecte la válvula de combustible en la posición "Off".
5 . Deje que el generador siga funcionando hasta que se agote el combustible y se pare el motor.
Esto tarda normalmente unos minutos.
6 . El generador necesita enfriarse completamente antes de limpiarlo y guardarlo.
7 . Limpie el generador de acuerdo con la sección de mantenimiento.
8 . Cambie el aceite.
9 . Quite la bujía y vierta aproximadamente media onza (14,8 ml) de aceite en el cilindro. Haga
girar el motor lentamente para distribuir el aceite y lubricar el cilindro.
1 0. Reacople la bujía.
1 1. Guarde la unidad en un lugar limpio y seco alejado de la luz solar directa.
Page 20
Nuestros motores funcionan bien con combustibles de mezcla de etanol del 10 % o menores.
Al utilizar combustibles mezclados hay algunos temas que valen la pena destacar:
Las mezclas de etanol y gasolina pueden absorber más agua que la gasolina
por sí sola.
Estas mezclas podrían separarse con el tiempo, dejando agua o una sustancia
acuosa en el tanque, la válvula de combustible y el carburador.
Con suministros de combustibles gravitatorios, este combustible
comprometido puede ser atraído al carburador y causar daños al motor y/o
peligros potenciales.
Hay solo unos pocos proveedores de estabilizador de combustible que están
formulados para funcionar con mezclas de combustible de etanol.
Cualquier daño o peligro causado por el uso impropio del combustible,
combustible almacenado incorrectamente y/o estabilizadores mal formulados
no están cubiertos por la garantía del fabricante.
Es recomendable cerrar siempre el suministro de combustible, haga funcionar el motor hasta
que se agote el combustible y drene el tanque cuando el equipo no esté en uso durante más
de 30 días.
9. RESOLUCIÓN DE PROBLEMAS
Page 21
Problema Causa Solución
El motor está en marcha,
pero no genera
electricidad.
1. El disyuntor está abierto.
2. Falla en el generador.
3. Conexión o conjunto de cables en
mal estado.
4. El dispositivo conectado está dañado.
1. Restablezca el disyuntor.
2. Comuníquese con una planta
de servicio autorizada.
3. Revise y repare.
4. Conecte otro dispositivo que
esté en buen estado
El motor funciona bien
sin cargas, pero se
atasca” cuando se
conectan cargas.
1. Cortocircuito en una carga conectada.
2. Velocidad del motor demasiado baja.
3. El generador está sobrecargado.
4. Cortocircuito en el generador.
1. Desconecte la carga eléctrica
con cortocircuito.
2. Comuníquese con una planta
de servicio autorizada.
3. Consulte la sección relativa a
no sobrecargar el generador.
4. Comuníquese con una planta
de servicio autorizada.
Al motor le falta potencia.
1. El interruptor del motor está en
la posición de apagado (0).
2. La palanca de corte de combustible
está en la posición de apagado (0).
3. Bajo nivel de aceite.
4. Depurador de aire sucio.
5. Se acabó el combustible.
6. El combustible está rancio.
7. El cable de la bujía no está
conectado a la bujía.
8. La bujía está en mal estado.
9. Hay agua en el combustible.
10. Ahogado.
11. Mezcla de combustible
excesivamente "rica".
12. La válvula de admisión está
atascada abierta o cerrada.
13. Pérdida de compresión en el
motor.
1. Coloque el interruptor del motor
en la posición de encendido (I).
2. Coloque la palanca de corte de
combustible en la posición
encendido (I).
3. Llene el cárter con el nivel
adecuado o coloque el generador
en una superficie nivelada.
4. Limpie o reemplace el depurador
de aire.
5. Llene el tanque de combustible.
6. Drene el tanque de combustible
y el carburador; llene con combustible
nuevo.
7. Conecte el cable a la bujía.
8. Reemplace la bujía.
9. Drene el tanque de gasolina y el
carburador; llene con combustible
nuevo.
10. Espere 5 minutos y haga partir
de nuevo el motor.
11. Comuníquese con una planta de
servicio autorizada.
12. Comuníquese con una planta de
servicio autorizada.
13. Comuníquese con una planta de
servicio autorizada.
1. La carga es demasiado alta.
2. Filtro de aire sucio.
1. No sobrecargue el generador.
2. Reemplace el filtro de aire.
La velocidad del motor
fluctúa.
La mezcla de combustible en el
carburador es demasiado rica o pobre.
Comuníquese con una planta de
servicio autorizada.
Page 22
Requisitos de la garantía
Firman generator registrará la garantía del generador tras recibir la Tarjeta de inscripción
de garantía y una copia del recibo de venta de uno de los puntos de venta minorista de
FIRMAN como comprobante de compra. Envié la inscripción de su garantía y comprobante
de compra dentro de diez (10) días a partir de la fecha de compra.
Garantía de reparaciones/reemplazos
Firman warrants to the original purchaser that the mechanical and electrical
components will be free of defects in material and workmanship for a period of one (1)
year (parts and labor) and two (2) years (parts) from the original date of purchase (90
days [parts and labor] and 180 days [parts] for commercial & industrial use. Transportation
charges on product submitted for repair or replacement under this warranty are the sole
responsibility of the purchaser. This warranty only applies to the original purchaser and
is not transferable.
No devuelva la unidad al lugar de compra
Comuníquese con el Centro de servicio de FIRMAN para abordar cualquier duda/problema
por teléfono o correo electrónico. Si el problema no puede resolverse mediante este método,
FIRMAN, a su elección, autorizará la evaluación, reparación o reemplazo de la pieza o
componente
defectuoso en un Centro de servicio de FIRMAN. FIRMAN le proporcionará un número de
caso
de servicio de garantía. Consérvelo para referencia futura. Esta garantía no cubrirá las
reparaciones o reemplazos efectuados sin previa autorización o en un centro de servicio
no autorizado.
Exclusiones de la garantía
Esta garantía no cubre las siguientes reparaciones ni equipos:
Desgaste normal
Su producto requiere piezas y mantenimiento regulares para funcionar debidamente. Esta
garantía no cubre reparaciones cuando el uso normal ha agotado la vida útil de una pieza o
equipo en general.
Instalación, uso y mantenimiento
Esta garantía no es válida para las piezas y/o mano de obra si se estima que el producto se
ha utilizado indebidamente, se ha descuidado, ha formado parte de un accidente, se han
contravenido sus instrucciones, se le han conectado cargas que superan el límite del
generador,
se ha modificado, se ha instalado indebidamente o se ha conectado incorrectamente a
cualquier
componente eléctrico. Esta garantía no cubre el mantenimiento normal del producto.
Otras exclusiones
Esta garantía excluye:
– defectos cosméticos tales como pintura, calcomanías, etc.,
– desgaste normal de artículos,
– accesorios,
– fallas debido a desastres naturales o catástrofes y otras circunstancias de fuerza mayor
que estén fuera del control del fabricante,
problemas originados por piezas que no sean las originales de FIRMAN.
10.Garantía limitada de dos (2) años de FIRMAN
Page 23
Límites de garantía implícita y daños resultantes
FIRMAN rechaza toda obligación de cubrir cualquier pérdida de tiempo, incapacidad de
usar este producto, transporte o cualquier daño resultante o fortuito exigido por alguien
que utilice este producto ESTA GARANTÍA INVALIDA A TODAS LAS DEMÁS GARANTÍAS,
EXPRESAS O IMPLÍCITAS, INCLUYENDO GARANTÍAS DE COMERCIABILIDAD O
IDONEIDAD PARA UN FIN EN PARTICULAR.
En una unidad que se proporcione como intercambio regirá la garantía de la unidad original.
La duración de la garantía correspondiente a la unidad intercambiada se calculará
considerando la fecha de compra de la unidad original.
Esta garantía le otorga ciertos derechos legales que pueden variar entre un estado y otro.
Además, puede que su estado le confiera otros derechos que no están incluidos en esta
garantía.
Información de contacto
Puede contactarse con FIRMAN en:
Dirección
SUMEC North America
Attn: Customer Service
2090 Baker Road Suite 304 Box 105
Kennesaw Ga. 30144
www.firmangenerators.com
Servicio al cliente
Lun-Vier 8:30 AM - 5:30 PM (Hora estándar del este - EE. UU.)
Sin costo:1-844-FIRMAN1 (1-844-347-6261)
WWW.FIRMANGENERATORS.COM
Toll Free:1-844-347-6261
Reservados todos los derechos. Se prohíbe expresamente toda
reimpresión o uso no autorizado sin permiso por escrito.
N/P:331535000 Rev 00
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Firman ECO1500 El manual del propietario

Categoría
Generadores de poder
Tipo
El manual del propietario

en otros idiomas