Modern Forms FM-74716 Sol Instrucciones de operación

Tipo
Instrucciones de operación
1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
HARDWARE
WARNING
IMPORTANT: NEVER attempt any work without shutting o the electricity.
- Read all instructions before installing.
- System is intended for installation by a qualied electrician in accordance with the National Electrical Code and local regulations.
- Go to the main fuse box, or circuit breaker. Place the main power switch in the OFF” position and unscrew the fuse(s) or switch ”OFF”
the circuit breaker switch(es) that control the power to the xture or room that you are working on.
- Place the wall switch in the “OFF” position.
CAUTION
- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are
worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this xture.
CAUTION When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
AVERTISSEMENT
IMPORTANT : Coupez l’électricité avant TOUTE manipulation.
- Lisez toutes les instructions avant d’installer.
- Système est destiné à être installé par un électricien qualié en conformité avec le code national de l’électricité et les
règlements locaux.
- Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt
(« OFF »).
- Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE
- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, nen laissez pas de côté
et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du
luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIA
IMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico.
- Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta
lámpara.
- Sistema está disenado para ser instalado por un electricista calicado, de acuerdo con el código eléctrico nacional y las normas locales.
- Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación
principal en la posición “OFF” (APAGADO).
- Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN
- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni
utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calicación
ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
INSTALLATION INSTRUCTION
747 - LED Flush Mount
FM-74712, FM-74716
Wire Connector
Qty: 3 pcs + 1 Extra
7EAC112201
P3
Junction Box Screw
Qty: 2 pcs + 1 Extra
7MPF0415C2
#8-32x9/16
Stainless Steel
Rubber Washer
Qty: 1 pc
7TGD250201WT
White
Metal Washer
Qty: 1 pc
7MBC500103
Stainless Steel
Hex Nut
Qty: 1 pc + 1 Extra
7MPM0904C1
Decorative Plate
Qty: 2 pcs
4MZH110027BN1 (BN) FM-74712
4MZH110027NI (PN) FM-74712
4MZH110163BN1 (BN) FM-74716
4MZH110163NI (PN) FM-74716
A1 B1 C1 D1 E1 F1
2Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
PREPARATION
1. Shut o the power at the circuit breaker and remove existing xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
CONNECTING THE WIRES (Fig. 2)
3. Unscrew the mounting screw from the xture, but let the mounting screw stay on the mounting plate. Rotate the xture until it can
be taken down.
4. Secure the mounting plate to the junction box using junction box screws (B1). The side of the mounting back plate marked “GND”
must face out
5. Connect the xture’s wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A1) are secured. If your outlet box
has a green or bare copper ground wire, connect the xtures ground wire to it. Otherwise, connect the xtures ground wire directly to the
back plate using the green screw provided. After wires are connected, tuck
them carefully inside the junction box.
MOUNTING THE FIXTURE (Fig. 1)
6. Put the xture slot through the mounting screw, rotate the xture until the
mounting screw head on the small side of the xture slot, then screw down the
mounting screw.
7. Put the glass through the screw bolt on the xture, place the rubber washer
(C1), metal washer (D1) on the screw bolt, then secure them with hex nut (E1).
8. Select BN or PN nish decorative plate (F1), thread it into the screw bolt.
Wire Connector
Junction Box Screw
Rubber Washer
Metal Washer
Hex Nut
Decorative Plate
Mounting Plate
Mounting Screw
Fixture Back Plate
Screw Tube
Glass
(RPL-GLA-74712)
(RPL-GLA-74716)
Ground Wire
Ground Wire Screw
Junction Box
A1
B1
C1
D1
E1
F1
FIG. 1
INSTALLATION INSTRUCTION
747 - LED Flush Mount
FM-74712, FM-74716
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Fig. 2 Wiring
1 3/4"
1 3/8"
Ø
4"
Back Plate Dimensions
  • Page 1 1
  • Page 2 2

Modern Forms FM-74716 Sol Instrucciones de operación

Tipo
Instrucciones de operación