LINEAR ENCODER MODEL: SAP
ENCODER LINEAL MODELO: SAP
Fagor Automation
Page 2/11 - "SAP" - V1503
Dimensions in mm
Dimensiones en mm
For / para CM > 620
CM = Curso de medición
Measuring length
G = Guia de la máquina
Machine guide
V1503 - "SAP" - Page 3/11
MOUNTING POSSIBILITIES
POSIBILIDADES DE MONTAJE
MOUNTING PRECAUTIONS
PRECAUCIONES PARA EL MONTAJE
Page 4/11 - "SAP" - V1503
PROCESO DE MONTAJE
MOUNTING PROCESS
- 1 - - 2 -
- 3 -
V1503 - "SAP" - Page 5/11
- 4 -
- 5 -
Washer / Arandela: AET 4.3
Washer / Arandela: AET 8.4
Pa = 20 Nm
M4x20 DIN 912
Pa = 2.5 Nm
M8x20 DIN 7984 Inox.
M4x20 DIN 912
Page 6/11 - "SAP" - V1503
- 7 - - 8 -
- 6 -
After mounting it on the machine
Tras montarla en la máquina
V1503 - "SAP" - Page 7/11
Option. Air intake on the endblock
Opción. Entrada de aire en la regla
Option. Air intake on the reader head
Opción. Entrada de aire en la cabeza
Quitar cierre / Remove lock screw: Allen SW 2.5
Pa = 1 Nm
Pa = 1 Nm
DIN ISO 8573-1
Class 1 - Particule Max. 0.1 µm
Class 4(7 bar) - Punto rocío / dewpoint 3ºC
Class 1 - Max. oil concentration 0.01 mg/m
3
· Unidades de filtro de aire recomendadas por FAGOR.
Modelos AI-400
AI-525 para 2 ejes,
AI-550 para 4 ejes,
AI-590 para 6 ejes.
· Air filters recommended by FAGOR.
Models: AI-400
AI-525 for 2 axes,
AI-550 for 4 axes,
AI-590 for 6 axes.
DIN ISO 8573-1
Class 1 - Particule Max. 0.1 µm
Class 4(7 bar) - Punto rocío / dewpoint 3ºC
Class 1 - Max. oil concentration 0.01 mg/m
3
· Unidades de filtro de aire recomendadas por FAGOR.
Modelos AI-400
AI-525 para 2 ejes,
AI-550 para 4 ejes,
AI-590 para 6 ejes.
· Air filters recommended by FAGOR.
Models: AI-400
AI-525 for 2 axes,
AI-550 for 4 axes,
AI-590 for 6 axes.
Page 8/11 - "SAP" - V1503
Note / Nota:
For lengths over 9 meters, a 1 m or 3 m cable and an extension cable must be used whose characteristics are:
5 x 2 x 0.14 mm
2
Para longitudes superiores a 9 metros, se debe utilizar un cable de 1 m ó 3 m y una alargadera cuyas
características sean: 5 x 2 x 0.14 mm
2
Absolute reference / Referencia absoluta:
The reference position between the reader head and the linear encoder is determined without having to move the
axis. The CNC can request the position of the linear encoder at any time.
La posición de referencia entre la cabeza lectora y el encoder lineal se determina sin tener que mover el eje. El
CNC puede solicitar la posición del encoder lineal en cualquier momento.
Absolute linear encoder with Panasonic protocol
Encoder lineal absoluto con protocolo Panasonic
Resolution
Resolución
A
ccurac
y
Precisión
Graduated
g
lass pitch
Vidrio
g
rabado de periodo
Maximum speed
Velocidad máxima
Maximum vibration
(
55 to 2000 Hz
)
Vibración máxima
(
55 a 2000 Hz
)
Shock
(
11 ms
)
Im
p
acto
(
11 ms
)
Movin
g
force
Fuerza de des
p
lazamiento
Sealin
rotection
Estan
q
ueidad
Sealin
g
p
rotection usin
g
an air inlet
Estan
q
ueidad con dis
p
ositivo de entrada de aire
Workin
g
tem
p
erature
Temperatura de trabajo
Stora
g
e tem
p
erature
Tem
p
eratura almacenamiento
Relative humidit
y
(
workin
g
or stora
g
e
)
Humedad relativa
(
traba
j
o o almacenamiento
)
Wei
g
ht
Peso
Power suppl
y
volta
g
e
Tensión de alimentación
Maximum power suppl
y
current
Corriente de alimentación máxima
Maximum cable len
g
th
Lon
g
itud de cable máxima
Cable bendin
g
radius
Radio de curvatura del cable
3 m/s
> 60 mm
300 m/s² (30 g)
DC 5V ± 10 %
30 m
(-4 °F.. 158 °F)
20 % ... 80 %
IP53
0.25 kg + 0.5 kg/m
(32 °F .. 122 °F)
-20 °C ..+70 °C
SAP10
50 nm
SAP50
10 nm
250 mA
±3 µm / ±5 µm
MECHANICAL CHARACTERISTICS /
CARACTERÍSTICAS MECÁNICAS
IP64
(DIN 40050)
0 °C .. 50 °C
100 m/s² (10 g)
< 4 N
ELECTRICAL CHARACTERISTICS /
CARACTERÍSTICAS ELÉCTRICAS
20 μm
V1503 - "SAP" - Page 9/11
ENCODER
PANASONIC
MINAS DRIVER
DATA
/DATA
5 V
0 V
RS-485
Page 10/11 - "SAP" - V1503
V1503 - "SAP" - Page 11/11
Mondragón a 1 de marzo de 2015Mondragón March 1st 2015
The information described in this manual may be
subject to variations due to technical modifications.
FAGOR AUTOMATION, S. Coop. Ltda. reserves the
right to modify the contents of this manual without
prior notice.
* Term: 12 months from factory invoice date.
* It covers parts and labor at FAGOR AUTOMATION.
* Travel expenses are payable by the customer.
* Damages due to causes external to FAGOR
AUTOMATION, such as unauthorized manipulation,
blows, etc. are not covered.
WARRANTY
La información descrita en este manual puede estar
sujeta a variaciones motivadas por modificaciones
técnicas.
FAGOR AUTOMATION S. Coop. Ltda. se reserva el
derecho de modificar su contenido, no estando
obligada a notificar las variaciones.
* 12 meses desde fecha de expedición de fábrica.
* Cubre gastos de Materiales y Mano de Obra de repa-
ración en FAGOR AUTOMATION.
* Gastos de desplazamiento a cargo del cliente.
* No cubre averías por causas ajenas a FAGOR
AUTOMATION, como: golpes, manipulación por per-
sonal no autorizado, etc.
GARANTIA
DECLARATION OF CONFORMITY
Manufacturer: Fagor Automation, S. Coop.
Barrio de San Andrés s/n, C.P. 20500, Mondragón -
Guipúzcoa- (SPAIN)
We declare under our exclusive responsibility the
conformity of the product referred to in this manual.
Note. Some additional characters may follow the model
references indicated in this manual. They all comply with
the following regulations:
ELECTROMAGNETIC COMPATIBILITY:
EN 61000-6-2:2005 Standard on immunity in industrial
environments
EN 61000-6-4:2007 Standard on emission in industrial
environments
According to the European Directive:
2004/108/CE on electromagnetic compatibility.
DECLARACION DE CONFORMIDAD
Fabricante: Fagor Automation, S. Coop.
Barrio de San Andrés s/n, C.P. 20500, Mondragón -
Guipúzcoa- (ESPAÑA)
Declaramos bajo nuestra exclusiva responsabilidad la
conformidad del producto al que hace referencia este
manual
Nota. Algunos caracteres adicionales pueden seguir a
las referencias de los modelos indicados en este
manual. Todos ellos cumplen con las siguientes normas:
COMPATIBILIDAD ELECTROMAGNÉTICA:
EN 61000-6-2:2005 Norma de Inmunidad en entornos
industriales
EN 61000-6-4:2007 Norma de Emisión en entornos
industriales
De acuerdo con las disposiciones de la Directiva
Comunitaria:
2004/108/CE de Compatibilidad Electromagnética.
Fagor Automation S. Coop.
Bº San Andrés Nº19
Apdo Correos 144
20500 - Arrasate/Mondragón
- Spain -
Web: www.fagorautomation.com
Tel.: (34) 943 719200
Fax: (34) 943 791712
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Fagor SA Series El manual del propietario

Tipo
El manual del propietario
Este manual también es adecuado para

en otros idiomas