DeWalt D55168 Manual de usuario

Categoría
Compresores de aire
Tipo
Manual de usuario
INSTRUCTION MANUAL
GUIDE D'UTILISATION
MANUAL DE INSTRUCCIONES
D55168
Oil Free Portable Air Compressor
Compresseur d’air portatif sans huile
Compresor de aire sin aceite portátil
INSTRUCTIVO DE OPERACIÓN, CENTROS DE SERVICIO
Y PÓLIZA DE GARANTÍA. ADVERTENCIA: LÉASE ESTE
INSTRUCTIVO ANTES DE USAR EL PRODUCTO.
DeWALT
Industrial Tool Co., 701 East Joppa Road, Baltimore, MD 21286
(MAR17) Part No. N503385 D55168 Copyright © 2007, 2008, 2009 2010, 2016, 2017
DeWALT
The following are trademarks for one or more
DeWALT
power tools: the yellow and black color scheme; the “D”
shaped air intake grill; the array of pyramids on the handgrip; the kit box configuration; and the array of lozenge-
shaped humps on the surface of thetool.
If you have questions or comments, contactus.
Pour toute question ou tout commentaire, nouscontacter.
Si tiene dudas o comentarios,contáctenos.
1-800-4-
DeWALT
• www.dewalt.com
Definitions: Safety Guidelines
The definitions below describe the level of severity for each signal word. Please read the
manual and pay attention to thesesymbols.
DANGER: Indicates an imminently hazardous situation which, if not avoided, will
result in death or seriousinjury.
WARNING: Indicates a potentially hazardous situation which, if not avoided, could
result in death or seriousinjury.
CAUTION: Indicates a potentially hazardous situation which, if not avoided, may
result in minor or moderateinjury.
NOTICE: Indicates a practice not related to personal injury which, if not avoided, may
result in property damage.
IF YOU HAVE ANY QUESTIONS OR COMMENTS ABOUT THIS OR ANY D
e
WALT TOOL,
CALL US TOLL FREE AT: 1-800-4-D
e
WALT (1-800-433-9258)
Important Safety Instructions
WARNING: Do not operate this unit until you read this instruction manual for safety,
operation and maintenanceinstructions.
WARNING: This product contains chemicals known to the State of California to cause
cancer, and birth defects or other reproductive harm. Wash hands afterhandling.
WARNING: Some dust contains chemicals known to the State of California to cause cancer,
birth defects or other reproductive harm such as asbestos and lead in lead basedpaint.
SAVE THESE INSTRUCTION
DANGER: RISK OF EXPLOSION OR FIRE
WHAT CAN HAPPEN HOW TO PREVENT IT
It is normal for electrical contacts
within the motor and pressure switch
tospark.
• Always operate the compressor in a well
ventilated area free of combustible materials,
gasoline, or solventvapors.
If electrical sparks from compressor
come into contact with flammable
vapors, they may ignite, causing fire
orexplosion.
If spraying flammable materials, locate
compressor at least 20' (6.1 m) away from
spray area. An additional length of hose may
berequired.
Store flammable materials in a secure
location away fromcompressor.
Restricting any of the compressor
ventilation openings will cause serious
overheating and could causefire.
Never place objects against or on top of
compressorpump.
Operate compressor in an open area at
least 12" (30.5 cm) away from any wall or
obstruction that would restrict the flow of
fresh air to the ventilationopenings.
• Operate compressor in a clean, dry well
ventilated area. Do not operate unit indoors
or in any confinedarea.
Unattended operation of this product
could result in personal injury or
property damage. To reduce the risk
of fire, do not allow the compressor to
operateunattended.
Always remain in attendance with the
product when it isoperating.
Always turn off and unplug unit when not
inuse.
DANGER: RISK TO BREATHING (ASPHYXIATION)
WHAT CAN HAPPEN HOW TO PREVENT IT
The compressed air directly from your
compressor is not safe for breathing.
The air stream may contain carbon
monoxide, toxic vapors, or solid
particles from the air tank. Breathing
these contaminants can cause serious
injury ordeath.
Never use air obtained directly from the
compressor to supply air for human
consumption. The compressor is not
equipped with suitable filters and in-line safety
equipment for human consumption.
Exposure to chemicals in dust created
by power sanding, sawing, grinding,
drilling, and other construction activities
may beharmful.
Sprayed materials such as paint, paint
solvents, paint remover, insecticides,
weed killers, may contain harmful
vapors andpoisons.
Work in an area with good cross ventilation.
Read and follow the safety instructions
provided on the label or safety data sheets
for the materials you are spraying. Always
use certified safety equipment: NIOSH/
OSHA respiratory protection or properly fit-
ting face mask designed for use with your
specificapplication.
WARNING: RISK OF BURSTING
Air Tank: On February 26, 2002, the U.S. Consumer Product Safety Commission published
Release # 02-108 concerning air compressor tank safety:
Air compressor receiver tanks do not have an infinite life. Tank life is dependent upon
several factors, some of which include operating conditions, ambient conditions, proper
installations, field modifications, and the level of maintenance. The exact effect of these
factors on air receiver life is difficult topredict.
If proper maintenance procedures are not followed, internal corrosion to the inner wall of the
air receiver tank can cause the air tank to unexpectedly rupture allowing pressurized air to
suddenly and forcefully escape, posing risk of injury toconsumers.
Your compressor air tank must be removed from service by the end of the year shown on
your tank warninglabel.
The following conditions could lead to a weakening of the air tank, and result in a violent air
tank explosion:
WHAT CAN HAPPEN HOW TO PREVENT IT
Failure to properly drain condensed
water from air tank, causing rust and
thinning of the steel airtank.
Drain air tank daily or after each use. If air tank
develops a leak, replace it immediately with a
new air tank or replace the entirecompressor.
Modifications or attempted repairs to the
airtank.
Never drill into, weld, or make any modifications
to the air tank or its attachments. Never
attempt to repair a damaged or leaking air
tank. Replace with a new airtank.
Unauthorized modifications to the safety
valve or any other components which
control air tankpressure.
• The air tank is designed to withstand specific
operating pressures. Never make adjustments
or parts substitutions to alter the factory set
operatingpressures.
Attachments & accessories:
Exceeding the pressure rating of air tools,
spray guns, air operated accessories,
tires, and other inflatables can cause
them to explode or fly apart, and could
result in seriousinjury.
Follow the equipment manufacturers
recommendation and never exceed the
maximum allowable pressure rating of
attachments. Never use compressor to
inflate small low pressure objects such as
children’s toys, footballs, basketballs,etc.
Tires:
Over inflation of tires could result in
serious injury and property damage.
Use a tire pressure gauge to check the tires
pressure before each use and while inflating
tires; see the tire sidewall for the correct tire
pressure.
NOTE: Air tanks, compressors and similar
equipment used to inflate tires can fill small
tires very rapidly. Adjust pressure regulator
on air supply to no more than the rating of
the tire pressure. Add air in small increments
and frequently use the tire gauge to prevent
overinflation.
WARNING: RISK OF ELECTRICAL SHOCK
WHAT CAN HAPPEN HOW TO PREVENT IT
Your air compressor is powered by
electricity. Like any other electrically
powered device, If it is not used properly
it may cause electricshock.
Never operate the compressor outdoors when
it is raining or in wetconditions.
Never operate compressor with protective
covers removed ordamaged.
Repairs attempted by unqualified
personnel can result in serious injury or
death byelectrocution.
Any electrical wiring or repairs required on this
product should be performed by a
DeWALT
factory service center or a
DeWALT
authorized
service center in accordance with national
and local electricalcodes.
Electrical Grounding: Failure to provide
adequate grounding to this product
could result in serious injury or death
from electrocution. See Grounding
Instructions underInstallation.
Make certain that the electrical circuit to
which the compressor is connected provides
proper electrical grounding, correct voltage
and adequate fuseprotection.
WARNING: RISK FROM FLYING OBJECTS
WHAT CAN HAPPEN HOW TO PREVENT IT
The compressed air stream can cause
soft tissue damage to exposed skin and
can propel dirt, chips, loose particles,
and small objects at high speed, resulting
in property damage or personalinjury.
Always wear certified safety equipment: ANSI
Z87.1 eye protection (CAN/CSA Z94.3) with
side shields when using thecompressor.
• Never point any nozzle or sprayer toward any
part of the body or at other people oranimals.
Always turn the compressor off and bleed
pressure from the air hose and air tank before
attempting maintenance, attaching tools
oraccessories.
WARNING: RISK OF HOT SURFACES
WHAT CAN HAPPEN HOW TO PREVENT IT
• Touching exposed metal such as the
compressor head, engine head, engine
exhaust or outlet tubes, can result in
seriousburns.
• Never touch any exposed metal parts on
compressor during or immediately after
operation. Compressor will remain hot for
several minutes afteroperation.
Do not reach around protective shrouds or
attempt maintenance until unit has been
allowed tocool.
WARNING: RISK FROM MOVING PARTS
WHAT CAN HAPPEN HOW TO PREVENT IT
Moving parts such as the pulley,
flywheel, and belt can cause serious
injury if they come into contact with you
or yourclothing.
• Never operate the compressor with guards or
covers which are damaged orremoved.
• Keep your hair, clothing, and gloves away
from moving parts. Loose clothes, jewelry, or
long hair can be caught in moving parts.
• Air vents may cover moving parts and should
be avoided as well.
Attempting to operate compressor
with damaged or missing parts or
attempting to repair compressor with
protective shrouds removed can expose
you to moving parts and can result in
seriousinjury.
Any repairs required on this product should
be performed by a
DeWALT
factory service
center or a
DeWALT
authorized servicecenter.
WARNING: RISK OF UNSAFE OPERATION
WHAT CAN HAPPEN HOW TO PREVENT IT
Unsafe op er a tion of your air compressor
could lead to se ri ous in ju ry or death to
you orothers.
Review and understand all instructions and
warnings in thismanual.
Be come fa mil iar with the op eration and con-
trols of the aircompressor.
• Keep operating area clear of all persons,
pets, andobstacles.
• Keep chil dren away from the air compressor
at alltimes.
Do not operate the product when fatigued or
under the influence of alcohol or drugs. Stay
alert at alltimes.
Never defeat the safety fea tures of thisprod-
uct.
Equip area of operation with a
fireextinguisher.
Do not op er ate machine with missing,
broken, or un au tho rizedparts.
WARNING: RISK OF FALLING
WHAT CAN HAPPEN HOW TO PREVENT IT
A portable compressor can fall from
a table, workbench, or roof causing
damage to the compressor and could
result in serious injury or death to
theoperator.
Always operate compressor in a stable secure
position to prevent accidental movement of
the unit. Never operate compressor on a roof
or other elevated position. Use additional air
hose to reach highlocations.
WARNING: RISK OF
INJURY FROM LIFTING
WHAT CAN HAPPEN HOW TO PREVENT IT
Serious injury can result from attempting
to lift too heavy anobject.
The compressor is too heavy to be lifted by
one person. Obtain assistance from others
beforelifting.
WARNING: RISK FROM NOISE
WHAT CAN HAPPEN HOW TO PREVENT IT
Under some conditions and duration
of use, noise from this product may
contribute to hearing loss.
Always wear proper hearing protection
duringuse.
SAVE THESE INSTRUCTIONS FOR FUTURE USE
Components (Fig. 1)
A. Mini-Switch F. Check Valve
B. Air Tank Pressure Gauge G. Safety Valve
C. Regulated Pressure Gauge H. Air Tank Drain Valve
D. Pressure Regulator I. Air Intake Filter
E. Quick Connect
FEATURES (FIG. 1)
MINI-SWITCH
Place this switch (A) in the ON(I) position to start the unit and OFF(0) to remove power at the
end of each use.
PRESSURE SWITCH
The pressure switch automatically starts the motor when the air tank pressure drops below
the factory set cut-in pressure. It stops the motor when the air tank pressure reaches the
factory set cut-outpressure.
SAFETY VALVE
If the pressure switch does not shut off the air compressor at its cut-out pressure setting, the
safety valve (G) will protect against high pressure by popping out at its factory set pressure
(slightly higher than the pressure switch cut-outsetting).
CHECK VALVE
When the air compressor is operating, the check valve (F) is open, allowing compressed air
to enter the air tank. When the air compressor reaches cut-out pressure, the check valve
closes, allowing air pressure to remain inside the airtank.
TANK PRESSURE GAUGE
The tank pressure gauge (B) indicates the reserve air pressure in the tank.
REGULATED PRESSURE GAUGE
The outlet pressure gauge (C) indicates the air pressure available at the outlet side of the
regulator. This pressure is controlled by the regulator.
REGULATOR
The regulator (D) controls the air pressure shown on the regulated pressure gauge. Pull the
knob out and turn clockwise to increase pressure and counterclockwise to decrease pres-
sure. When the desired pressure is reached push knob in to lock in place. The regulated
pressure range is 7–150psi.
WARNING: Risk of Bursting. Too much air pressure causes a hazardous risk of bursting.
Check the manufacturer’s maximum pressure rating for air tools and accessories. The regula-
tor outlet pressure must never exceed the maximum pressurerating.
UNIVERSAL QUICK CONNECT BODY
The universal quick connect body (E) accepts the three most popular styles of quick connect
plugs: Industrial, automotive, and ARO. One hand push-to-connect operation makes con-
nections simple and easy.
DRAIN VALVE
The drain valve (H) is located at the base of the air tank and is used to drain condensation at
the end of each use. See Draining Air Tank under Maintenance.
COOLING SYSTEM
This compressor contains an advanced design cooling system. It is normal for this fan to
blow air through the vent holes in large amounts. The cooling system is working when air
isexpelled.
AIR COMPRESSOR PUMP
The pump compresses air into the air tank. Working air is not available until the compressor
has raised the air tank pressure above that required at the airoutlet.
AIR INTAKE FILTER
The filter (I) is designed to clean air entering the pump. To ensure the pump continually
receives a clean, cool, and dry air supply the filter must always be clean and the filter intake
must be free fromobstructions.
Final page size 10.875" x 25"
MOTOR OVERLOAD PROTECTOR
The motor has a thermal overload protector. If the motor overheats for any reason, the
overload protector will shut off the motor. The motor must be allowed to cool down before
restarting. To restart:
1. Set the Mini-Switch to OFF(0) and unplug unit.
2. Allow the motor tocool.
3. Plug the power cord into the correct branch circuitreceptacle.
4. Set the Mini-Switch to ON(I) position.
INSTALLATION
Assembly
INSTALLING HOSES
WARNING: Risk of unsafe operation. Firmly grasp hose in hand when installing or discon-
necting to prevent hosewhip.
1. Ensure regulated pressure gauge reads 0 psi.
2. Grasp the hose at the quick connect plug and push the plug into the quick connect
body (E). Coupler will snap intoplace.
3. Grasp the hose and pull to ensure coupler isseated.
DISCONNECTING HOSES
WARNING: Risk of unsafe operation. Firmly grasp hose in hand when installing or discon-
necting to prevent hosewhip.
1. Ensure regulated pressure gauge reads 0psi.
2. Pull coupler on quick connect body back to release quick connect plug onhose.
FITTING THE WHEELS (FIG.4)
1. Insert the bolt through the wheel and bracket as shown in Fig.4.
2. Holding the locking nut in place with a wrench, tighten the wheel boltsecurely.
3. Repeat these steps for the oppositewheel.
FITTING THE BUMPERS (FIG.5)
1. Insert threaded bolt through the isolator and thread into the bracket hole as shown in
Fig.5. Tighten the boltsecurely.
2. Repeat these steps for the oppositebumper.
Grounding Instructions (Fig. 2)
WARNING: Risk of Electrical Shock. In the event of a short circuit, grounding reduces the
risk of shock by providing an escape wire for the electric current. This air compressor must
be properlygrounded.
The portable air compressor is equipped with a cord having a grounding wire with an appro-
priate grounding plug.
1. The cord set and plug (M) with this unit contains a grounding pin (L). This plug MUST be
used with a grounded outlet (K).
IMPORTANT: The outlet being used must be installed and grounded in accordance with all
local codes and ordinances.
2. Ensure the outlet being used has the same configuration as the grounded plug. DO NOT
USE ANADAPTER.
3. Inspect the plug and cord before each use. Do not use if there are signs ofdamage.
4. If these grounding instructions are not completely understood, or if in doubt as to
whether the compressor is properly grounded, have the installation checked by a quali-
fiedelectrician.
DANGER: Risk of Electrical Shock. IMPROPER GROUNDING CAN RESULT IN
ELECTRICALSHOCK.
Do not modify the plug provided. If it does not fit the available outlet, a correct outlet
should be installed by a qualifiedelectrician.
Repairs to the cord set or plug MUST be made by a qualifiedelectrician.
Extension Cords
If an extension cord must be used, be sure it is:
a 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle that
will accept the plug on the product
• in good condition
• no longer than 50 feet (15.2 m)
12 gauge (AWG) or larger. (Wire size increases as gauge number decreases. 10 AWG and
8 AWG may also be used. DO NOT USE 14 OR 16 AWG.)
NOTICE: Risk of Property Damage. The use of an undersized extension cord will cause volt-
age to drop resulting in power loss to the motor and overheating. Instead of using an exten-
sion cord, increase the working reach of the air hose by attaching another length of hose to
its end. Attach additional lengths of hose asneeded.
Voltage and Circuit Protection
Refer to the Voltage and Minimum Branch Circuit Requirements under Specifications.
CAUTION: Risk of Overheating. Certain air compressors can be operated on a 15 amp
circuit if the following conditions are met.
Voltage supply to circuit must comply with the National ElectricalCode.
Circuit is not used to supply any other electricalneeds.
Extension cords comply withspecifications.
Circuit is equipped with a 15 amp circuit breaker or 15 amp time delay fuse.
NOTE: If compressor is connected to a circuit protected by fuses, use only time delay
fuses. Time delay fuses should be marked “D” in Canada and “T” in the US.
If any of the above conditions cannot be met, or if operation of the compressor repeatedly
causes interruption of the power, it may be necessary to operate it from a 20 amp circuit. It
is not necessary to change the cordset.
Compatibility
NOTE: Always use an air line filter to remove moisture and oil vapor when sprayingpaint.
Location
Place the air compressor in a clean, dry and well ventilated area at least 12" (30.5 cm) away
from the wall or other obstructions that will interfere with the flow of air. Keep the compressor
away from areas that have dirt and/or volatile fumes in the atmosphere. These impurities may
clog the intake filter and valves, causing inefficient operation.
WARNING: The air compressor pump and shroud are designed to allow for proper cool-
ing. The ventilation openings on the compressor are necessary to maintain proper operating
temperature. Do not place rags or other containers on or near theseopenings.
Place the air compressor on a flat surface resting on the rubber feet andwheels.
ELECTRICAL
Refer to all safety instructions before using unit. Observe extension cord safety instructions
if necessary. Always place the switch to the OFF(0) position before removing the plug from
the outlet.
TRANSPORTING (FIG. 3)
When transporting the compressor in a vehicle, trailer, etc., make sure the tank is drained and
the unit is secured with straps to prevent tipping. Use care when driving to prevent tipping
the unit over in the vehicle. Damage can occur to the compressor or surrounding items if the
compressor istipped.
LIFTING
Always use two people when lifting and lift from the recommended lift points (N). DO NOT
lift by wheels or shroud.
MOVING
CAUTION: The wheels and handle do not provide adequate clearance, stability, or
support for pulling the unit up and down stairs or steps. The unit must be lifted or
pushed up aramp.
1. Grasp handle of compressor and tilt compressor back to rest onwheels.
WARNING: Risk of Unsafe Operation. Ensure proper footing and use caution when rolling
compressor so that unit does not tip or cause loss ofbalance.
2. When location is reached slowly lower compressor to ground. Always store compres-
sor in a vertical position resting on the rubber bumpers andwheels.
PREPARATION FOR USE
WARNING: Do not operate this unit until you read this instruction manual for safety,
operation and maintenanceinstructions.
Pre-Start Checklist (Fig. 1)
1. Ensure the Mini-Switch (A) is in the OFF(0) position.
2. Plug the power cord into the correct branch circuit receptacle. See Voltage and Circuit
Protection underInstallation.
3. Ensure air tank is drained, see Draining Air Tank under Maintenance.
4. Ensure the drain valve (H) is closed.
5. Ensure safety valve (G) is functioning properly, see Checking Safety Valve
underMaintenance.
6. Pull the regulator knob (D) out and turn counterclockwise until fully closed. Ensure regu-
lated pressure gauge reads 0 psi. Push knob in to lock in place.
7. Attach hose and accessories. NOTE: Always use a minimum 3/8" (9.5 mm) or greater air
hose rated at 300 psi.
WARNING: Risk of unsafe operation. Firmly grasp air hose in hand when installing or dis-
connecting to prevent hosewhip.
WARNING: Risk of unsafe operation. Do not use damaged or wornaccessories.
WARNING: Risk of Bursting. Too much air pressure causes a hazardous risk of bursting.
Check the manufacturer’s maximum pressure rating for air tools and accessories. The regula-
tor outlet pressure must never exceed the maximum pressure rating.
OPERATING PROCEDURES
Start-up (Fig. 1)
1. Follow Pre-Start Checklist under Preparation forUse.
2. Move the Mini-switch to the ON(I) position and allow tank pressure to build. Motor will
stop when tank pressure reaches cut-outpressure.
NOTICE: Risk of Property Damage. Compressed air from the unit may contain wa ter conden-
sation and oil mist. Do not spray un fil tered air at an item that could be damaged by moisture.
Some air op er ated tools or de vic es may require filtered air. Read the in struc tions for the air
tool ordevice.
3. Adjust regulator (D) to desired setting. See Regulator underFeatures.
Shut-down (Fig. 1)
1. Move Mini-Switch (A) to the OFF(0) position.
NOTE: If finished using compressor, follow Steps 2–6.
NOTE: When the unit has been turned off, it is normal to hear a short hiss of air beingreleased.
NOTE: Unplug unit when not inuse.
2. Pull the regulator knob (D) out and turn counterclockwise until fully closed. Ensure regu-
lated pressure gauge reads 0 psi. Push knob in to lock in place.
3. Remove hose andaccessory.
WARNING: Risk of unsafe operation. Firmly grasp air hose in hand when installing or dis-
connecting to prevent hosewhip.
4. Drain the air tank, see Draining Air Tank under Maintenance. Ensure air tank pressure
gauge reads 0psi.
WARNING: Risk of bursting. Drain air tank daily. Water will condense in air tank. If not
drained, water will corrode and weaken the air tank causing a risk of air tankrupture.
5. Allow the compressor to cooldown.
6. Wipe air compressor clean and store in a safe, non-freezingarea.
MAINTENANCE
The following procedures must be followed when maintenance or service is performed on
the aircompressor.
1. Ensure Mini-Switch is in the OFF(0) position.
2. Remove air compressor plug fromoutlet.
3. Drain airtank.
4. Allow air compressor to cool down before startingservice.
NOTE: All compressed air systems contain maintenance parts (e.g., oil, filters, separators)
that are periodically replaced. These used parts may contain substances that are regulated
and must be disposed of in accordance with local, state, and federal laws andregulations.
NOTE: Take note of the positions and locations of parts during disassembly to make reas-
semblyeasier.
NOTE: Any service operations not included in this section should be performed by a
DeWALT
factory service center or a
DeWALT
authorized servicecenter.
Maintenance Chart
Procedure Daily Weekly See tank
warning label
Check safety valve X
Inspect air filter X
Drain air tank X
Check for unusual noise/vibration X
Check for air leaks X
1
Clean compressor exterior X
Remove tank from service X
2
1 - To check for air leaks apply a solution of soapy water around joints. While compressor
is pumping to pressure and after pressure cuts out, look for air bubbles toform.
2 - For more information, call 1-800-4-
DeWALT
(1-800-433-9258)
Checking Safety Valve
WARNING: Risk of bursting. If the safety valve does not work properly, over-pressurization
may occur, causing air tank rupture or anexplosion.
WARNING: Risk from flying objects. Always wear certified safety equipment: ANSI Z87.1
eye protection (CAN/CSA Z94.3) with side shields when using thecompressor.
Before starting compressor, pull the ring on the safety valve to make sure that the safety
valve operates freely. NOTE: Ring may be difficult to pull when air tank pressure is at 0 psi.
If the valve is stuck or does not operate smoothly, it must be replaced with the same type
of valve.
Draining Air Tank (Fig. 1)
WARNING: Risk of unsafe operation. Risk from noise. Air tanks contain high pres-
sure air. Keep face and other body parts away from outlet of drain. Use eye protection
[ANSI Z87.1 (CAN/CSA Z94.3)] when draining as debris can be kicked up into face.
WARNING: Risk from noise. Always wear proper hearing protection during use. Under
some conditions and duration of use, noise from this product may contribute to hearingloss.
NOTE: All compressed air systems generate condensate that accumulates in any drain point
(e.g. tanks, filter, aftercoolers, dryers). This condensate contains lubricating oil and/or sub-
stances which may be regulated and must be disposed of in accordance with local, state,
and federal laws andregulations.
WARNING: Risk of bursting. Drain air tank daily. Water will condense in air tank. If not
drained, water will corrode and weaken the air tank causing a risk of air tankrupture.
NOTICE: Risk of Property Damage. Drain water from air tank may contain oil and rust, which
can causestains.
1. Ensure Mini-Switch is in the OFF(0) position.
2. Place a suitable container under the drain valve (H) to catchdischarge.
3. Grasp lever on drainvalve.
4. Slowly rotate lever to gradually bleed air from airtank.
5. When air tank pressure gauge reads 10 psi, rotate valve to the fully openposition.
6. Close drain valve whenfinished.
Checking Air Filter Element (Fig. 1)
WARNING: Hot surfaces. Risk of burn. Outlet tube, pump head, and surrounding parts are
very hot, do not touch. Allow compressor to cool prior to servicing.
1. Ensure Mini-Switch is in the OFF(0) position.
2. Allow unit tocool.
3. Remove filter cover (J) from base.
4. Remove element from filter base.
5. Place new element back in filter base. Purchase replacement parts from your local dealer
or authorized service center. Always use identical replacement parts.
6. Snap filter cover to filter base.
NOTICE: Risk of unsafe operation. Do not operate without air inlet filter
Accessories
WARNING: The use of any other accessory not recommended for use with this tool
could be hazardous. Use only accessories rated equal to or higher than the rating of the
aircompressor.
Recommended accessories for use with your tool are available for purchase from your local
dealer or authorized service center. If you need assistance in locating any accessory for your
tool, please contact D
e
WALT Industrial Tool Co., 701 East Joppa Road, Towson, MD 21286,
call 1-800-4-D
e
WALT (1-800-433-9258) or visit our website www.dewalt.com.
Service Information
Please have the following information available for all service calls:
Model Number _____________________ Serial Number ________________________________
Date and Place of Purchase _______________________________________________________
Repairs
To assure product SAFETY and RELIABILITY, repairs, maintenance and adjustment should
be performed by a D
e
WALT factory service center, a D
e
WALT authorized service center or
other qualified service personnel. Always use identical replacementparts.
Full One Year Warranty
D
e
WALT heavy duty industrial tools are warranted for one year from date of purchase. We
will repair, without charge, any defects due to faulty materials or workmanship. For warranty
repair information, call 1-800-4-D
e
WALT (1-800-433-9258). This warranty does not apply to
accessories or damage caused where repairs have been made or attempted by others. This
warranty gives you specific legal rights and you may have other rights which vary in certain
states orprovinces.
LATIN AMERICA: This warranty does not apply to products sold in Latin America. For
products sold in Latin America, see country specific warranty information contained either in
the packaging, call the local company or see website for warrantyinformation.
FREE WARNING LABEL REPLACEMENT (Fig. 6): If your warning labels become illegible or
are missing, call 1-800-4-D
e
WALT (1-800-433-9258) for a freereplacement.
GLOSSARY
CFM: Cubic feet perminute.
SCFM: Standard cubic feet per minute; a unit of measure of air delivery.
PSI: Pounds per square inch; a unit of measure ofpressure.
kPa (kilopascal): Metric pressure measurement. 1 kilopascal equal 1000 pascals.
Code Certification: Products that bear one or more of the following marks: UL
®
, CUL,
CULUS, ETL
®
, CETL, CETLUS, have been evaluated by OSHA certified independent safety
laboratories and meet the applicable Standards forSafety.
*UL
®
is a registered trademark of Underwriters Laboratories and ETL
®
is a registered
trademark of Electrical TestingLaboratories.
FIG. 1
L
M
K
FIG. 2
FIG. 3
DRAIN TANK DA ILY
H
N
N
I
D
C
B
E
F
H
WARNING HOT SURFACES
ADVERTENCIA SUPERFICIES CALIENTES
AVERTISSEMENT
SURFACES CHAUDES
DO NOT ADJUST FACTORY SETTINGS.
TO REDUCE RISK OF ELE CTRIC SHOCK
DO NOT REMOVE COVER.
Pressure controls set at fact ory for
maximum sa fe operation.
NO HAGA CAMBIOS EN LOS AJUSTES
DE FÁBRICA. NO RETIRE LA TAPA PARA
REDUCIR EL RIESGO DE CHOQUE ELÉ C TRICO.
Los controles de presión se ajustan en la
fábrica para máxima segu ridad en la ope ración.
ADVERTENCIA
WARNING
AVERTISSEMENT
FIG. 4
FIG. 5
A
G
Cut-In Pressure: While the motor is off, air tank pressure drops when accessory is used.
When the tank pressure drops to a certain low level the motor will restart automatically. The
low pressure at which the motor automatically restarts is called cut-inpressure.
Cut-Out Pressure: When an air compressor is turned on and begins to run, air pressure
in the air tank begins to build. It builds to a certain high pressure before the motor
automatically shuts off, protecting your air tank from pressure higher than its capacity. The
high pressure at which the motor shuts off is called cut-outpressure.
Branch Circuit: The circuit carrying electricity from electrical panel tooutlet.
Duty Cycle: This air compressor pump is capable of running continuously. However,
to prolong the life of your air compressor, it is recommended that a 50%-75% average
duty cycle be maintained; that is, the air compressor pump should not run more than
30-45 minutes in any given hour.
Troubleshooting Guide
This section provides a list of the more frequently encountered malfunctions, their causes
and corrective actions. The operator or maintenance personnel can perform some corrective
actions, and others may require the assistance of a qualified D
e
WALT technician or
yourdealer.
Problem Code
Excessive air tank pressure-safety valve pops off ................................................ 1, 2
Air leaks ................................................................................................................... 3
Air leaks in air tank or at air tank welds ................................................................... 4
Air leaks between head and valve plate ................................................................... 5
Air leaks from safety valve ........................................................................................ 6
Knocking Noise ........................................................................................................ 6
Pressure reading on the regulated pressure gauge
drops when an accessory is used ............................................................................ 7
Compressor is not supplying enough air to operate accessories .............................
...................................................................................................... 8, 9, 10, 11, 12, 22
Regulator knob has continuous air leak ................................................................. 13
Regulator will not shut off air outlet ....................................................................... 13
Motor will not run ...........................................................6, 14, 15, 16, 17, 18, 19, 20
Squealing Sound .................................................................................................... 21
Troubleshooting Codes
CODE POSSIBLE CAUSE POSSIBLE SOLUTION
1 Pressure switch does
not shut off motor
when compressor
reaches cut-out
pressure
Set the Mini-Switch to OFF(0), if the unit does not shut off
contact a D
e
WALT factory service center or a D
e
WALT authorized
servicecenter.
2 Pressure switch cut-out
too high
Contact a D
e
WALT factory service center or a D
e
WALT authorized
servicecenter.
3 Tube fittings are not
tight enough
Tighten fittings where air can be heard escaping. Check fittings
with soapy water solution. Do NotOvertighten.
4 Defective air tank Air tank must be replaced. Do not repair theleak.
WARNING: Risk of bursting. Do not drill into, weld or otherwise
modify air tank or it will weaken. The air tank can rupture
orexplode.
5 Leaking seals Contact a D
e
WALT factory service center or a D
e
WALT authorized
servicecenter.
6 Defective safety valve Operate safety valve manually by pulling on ring. If valve still
leaks, it must bereplaced.
7 Regulator is not
adjusted correctly for
accessory being used
It is normal for some pressure drop to occur when an accessory
is used, adjust the regulator as instructed in Regulator under
Features if pressure drop isexcessive.
NOTE: Adjust the regulated pressure under flow conditions while
accessory is beingused.
8 Prolonged excessive
use of air
Decrease amount of airusage.
9 Compressor is not
large enough for
accessory
Check the accessory air requirement. If it is higher than the CFM
or pressure supplied by your air compressor, a larger compressor
is needed to operateaccessory.
10 Hole in air hose Replace airhose.
11 Check valve restricted Contact a D
e
WALT factory service center or a D
e
WALT authorized
servicecenter.
12 Air leaks Tightenfittings.
13 Regulator is damaged Replace.
14 Motor overload
protection switch has
tripped
Refer to Motor Overload Protection under Features. If motor
overload protection trips frequently, contact a D
e
WALT factory
service center or a D
e
WALT authorized servicecenter.
15 Tank pressure exceeds
pressure switch cut-in
pressure
Motor will start automatically when tank pressure drops below cut-
in pressure of pressureswitch.
16 Extension cord is wrong
length or gauge
Check for proper gauge wire and cord length. Refer to the
Extension Cords paragraph in the Installationsection.
17 Loose electrical
connections
Contact a D
e
WALT factory service center or a D
e
WALT authorized
servicecenter.
18 Possible defective
motor
Contact a D
e
WALT factory service center or a D
e
WALT authorized
servicecenter.
19 Paint spray on internal
motor parts
Contact a D
e
WALT factory service center or a D
e
WALT authorized
service center. Do not operate the compressor in the paint spray
area. See flammable vaporwarning.
20 Fuse blown, circuit
breaker tripped
1. Check fuse box for blown fuse and replace as necessary.
Reset circuit breaker. Do not use a fuse or circuit breaker
with higher rating than that specified for our particular
branchcircuit.
2. Check for proper fuse. You should use a time delayfuse.
3. Check for low voltage conditions and/or proper
extensioncord.
4. Disconnect the other electrical appliances from circuit or
operate the compressor on its own branchcircuit.
21 Worn Belt Contact a D
e
WALT factory service center or a D
e
WALT authorized
servicecenter.
22 Restricted air intake
filter
Clean or replace air intake filter. Do not operate the air compressor
with the filter removed. Refer to the Air Filter paragraph in the
Maintenancesection.
Définitions : lignes directrices en
matière de sécurité
Les définitions ci-dessous décrivent le niveau de gravité pour chaque symbole. Veuillez lire le
mode d’emploi et porter une attention particulière à cessymboles.
DANGER : Indique une situation dangereuse imminente qui, si elle n’est pas évitée,
causera la mort ou des blessuresgraves.
AVERTISSEMENT :
Indique une situation potentiellement dangereuse qui, si elle n’est pas
évitée, pourrait se solder par un décès ou des blessuresgraves.
ATTENTION : Indique une situation potentiellement dangereuse qui, si elle n’est pas évitée
pourrait se solder par des blessures mineures oumodérées.
AVIS : Indique une pratique ne posant aucun risque de dommages corporels
mais qui par contre, si rien n’est fait pour l’éviter, pourrait poser des risques de
dommagesmatériels.
POUR TOUTES QUESTIONS OU COMMENTAIRES RELATIFS(VES) À L’OUTIL OU À
PROPOS DE TOUT AUTRE OUTIL
DeWALT
, COMPOSER SANS FRAIS LE : 1-800-4-
DeWALT
(1-800-433-9258)
Directives de sécurité importantes
AVERTISSEMENT : ne pas utiliser cet appareil avant d’avoir lu le mode d’emploi ainsi que
l’intégralité des directives de sécurité, d’utilisation et d’entretien.
AVERTISSEMENT :
ce produit contient des produits chimiques reconnus par l’État de
la Californie comme étant cancérigènes et pouvant entraîner des anomalies congénitales
ou d’autres problèmes liés aux fonctions reproductrices. Se laver les mains après
toutemanipulation.
AVERTISSEMENT :
certaines poussières contiennent des produits chimiques reconnus
par l’État de la Californie comme cancérigènes et pouvant entraîner des anomalies
congénitales et d’autres problèmes liés aux fonctions reproductrices, tels que l’amiante et le
plomb contenus dans les peintures auplomb.
CONSERVER CES DIRECTIVES
DANGER :
RISQUE D’EXPLOSION OU D’INCENDIE
CE QUI PEUT SE PRODUIRE COMMENT L’ÉVITER
Il est normal que des contacts
électriques dans le moteur et le
manocontacteur fassent uneétincelle.
Faites toujours fonctionner le compresseur dans
une zone bien aérée sans matière combustible,
essence ou vapeur desolvant.
Si une étincelle électrique provenant
du compresseur entre en contact avec
des vapeurs inflammables, elle peut
s’enflammer et causer un incendie ou
uneexplosion.
Si vous aspergez des matériaux inflammables,
placez le compresseur à au moins 6,1 m (20 pieds)
de la zone pulvérisée. Il est possible que vous ayez
besoin d’une longueur de tuyauadditionnelle.
Entreposez les matières inflammables dans un
endroit sécuritaire, éloigné ducompresseur.
Le fait de limiter les ouvertures
d’aération de compresseur causera
une importante surchauffe et pourrait
causer unincendie.
Ne jamais placer d'objets contre la pompe du
compresseur ou sur celle-ci.
Faites fonctionner le compresseur dans un endroit
aéré à au moins 30,5 cm (12 po) du mur ou de
l’obstruction qui pourrait limiter le débit d’air frais
dans les ouvertures d’aération.
Faites fonctionner le compresseur dans un endroit
propre, sec et bien aéré. Ne pas utiliser l’appareil
à l’intérieur ou dans un endroitexigu.
Le fonctionnement de ce produit
sans surveillance pourrait se solder
par des blessures personnelles ou
des dommages à la propriété. Afin
de réduire le risque d’incendie, ne
pas laisser le compresseur fonctionner
sanssurveillance.
Être toujours présent lorsque le produit est
enmarche.
Toujours éteindre et débrancher l'appareil si
nonutilisé.
DANGER : RISQUE REPIRATOIRE (ASPHYXIE)
CE QUI PEUT SE PRODUIRE COMMENT L’ÉVITER
Il est dangereux de respirer l’air
comprimé sortant du compresseur. Le
flux d’air peut contenir du monoxyde
de carbone, des vapeurs toxiques ou
des particules solides provenant du
réservoir d’air. La respiration de ces
contaminants peut causer de sérieuses
blessures, voire lamort.
Ne jamais utiliser l’air obtenu directement du
compresseur pour l’alimentation en air destinée à
la consommation humaine. Le compresseur n’est
pas muni de filtres et d’équipement de sécurité en
ligne qui conviennent à la consommationhumaine.
Une exposition aux produits
chimiques présents dans la
poussière générée par les activités
de ponçage, sciage, meulage,
perçage et autres, peut êtrenocive.
Les matériaux vaporisés comme la
peinture, les solvants de peinture,
les décapants, les insecticides, les
herbicides, pourraient contenir des
vapeurs nocives et dupoison.
Travailler dans un endroit ayant une bonne
aération transversale. Lire et respecter les
directives en matière de sécurité imprimées
sur l’étiquette ou les fiches signalétiques des
matériaux qui sont pulvérisés. Toujours utiliser
un équipement de sécurité homologué : une
protection respiratoire conforme aux normes
NIOSH/OSHA, ou un masque facial bien
ajusté, conçus spécifiquement pour votre
utilisationparticulière.
AVERTISSEMENT : RISQUE D’ÉCLATEMENT
Réservoir d’air comprimé : Le 26 février 2002, la U.S. Consumer Product Safety
Commission américaine a publié la règle nº 02-108 portant sur la sécurité en matière de
réservoir d’air comprimé des compresseurs:
Les réservoirs d’air comprimé des compresseurs n’ont pas une durée de vie illimitée.
La durée de vie des réservoirs dépend de plusieurs facteurs, qui comprennent entre
autres: les conditions d’utilisation, les conditions ambiantes, une installation adéquate, les
modifications sur site, et le niveau de maintenance. L’effet exact que peut avoir ces facteurs
sur la durée de vie des réservoirs d’air est difficilementprévisible.
Si les procédures adéquates de maintenance ne sont pas suivies, la corrosion sur la
paroi interne du réservoir d’air comprimé peut faire que celui-ci éclate de façon inopinée
laissant soudainement l’air pressurisé s’échapper avec force, posant ainsi des risques de
dommages corporels à l’utilisateur.
Le réservoir d’air de votre compresseur doit être mis hors service à la fin de l’année
mentionnée sur l’étiquette d’avertissement apposée sur leréservoir.
Les conditions suivantes peuvent amener la dégradation du réservoir d’air, et faire que ce
dernier explose violemment:
CE QUI PEUT SE PRODUIRE COMMENT L’ÉVITER
L’eau condensée n’est pas
correctement vidangée du réservoir
d’air provoquant ainsi la formation
de rouille et un amincissement du
réservoir d’air enacier.
Vidanger le réservoir d’air quotidiennement
ou après chaque utilisation. Si le réservoir
présente une fuite, le remplacer immédiatement
par un nouveau réservoir d’air ou par un
nouveaucompresseur.
• Modifications apportées au réservoir
d’air ou tentatives deréparation.
Ne jamais percer un trou dans le réservoir d’air
ou ses accessoires, y faire de la soudure ou
y apporter quelque modification que ce soit.
Ne jamais essayer de réparer un réservoir d’air
endommagé ou avec des fuites. Le remplacer par
un nouveau réservoir d’air.
Des modifications non autorisées de la
soupape de sûreté ou de tous autres
composants qui régissent la pression
du réservoir d’air.
Le réservoir d’air a été conçu pour supporter
des pressions spécifiques de fonctionnement.
Ne faites jamais effectuer de réglages ou de
substitutions de pièces en vue de modifier les
pressions de fonctionnement réglées enusine.
Accessoires :
Lorsqu’on excède la pression nominale
des outils pneumatiques, des pistolets
pulvérisateurs, des accessoires à
commande pneumatique, des pneus
et d’autres dispositifs pneumatiques,
on risque de les faire exploser ou
de les projeter et ainsi entraîner des
blessuresgraves.
Respecter les recommandations du fabricant de
l’équipement et ne jamais dépasser la pression
nominale maximale permise des accessoires.
Ne jamais utiliser le compresseur pour gonfler de
petits objets à basse pression comme des jouets
d’enfant, des ballons de football et de basket-
ball,etc.
Pneus :
Des pneus surgonflés pourraient
provoquer des blessures graves et des
dommages à lapropriété.
Utiliser un manomètre pour vérifier la pression des
pneus avant chaque utilisation et lors du gonflage;
consulter le flanc de pneu pour obtenir la pression
correcte.
REMARQUE : Les réservoirs d’air comprimé,
compresseurs et autres équipements similaires
utilisés pour gonfler les pneus peuvent remplir ces
derniers très rapidement. Régler le régulateur de
pression d’air à une pression moindre que celle
indiquée sur le pneu. Ajouter de l’air par petite
quantité et utiliser fréquemment le manomètre
pour empêcher unsurgonflage.
AVERTISSEMENT : RISQUE DE CHOC ÉLECTRIQUE
CE QUI PEUT SE PRODUIRE COMMENT L’ÉVITER
Votre compresseur d’air est alimenté
à l’électricité. Tout comme n’importe
quel autre dispositif alimenté de
façon électrique, s’il n’est pas utilisé
correctement, il peut causer un
chocélectrique.
Ne faites jamais fonctionner le compresseur
à l’extérieur lorsqu’il pleut ou dans des
conditionshumides.
Ne faites jamais fonctionner le compresseur
avec les couvercles de protection enlevés
ouendommagés.
• Les tentatives de réparation par un
personnel non qualifié peuvent résulter
en de graves blessures, voire la mort
parélectrocution.
Tout câblage électrique ou toute réparation
nécessaire pour ce produit doit être pris en
charge par un centre de réparation en usine
autorisé
DeWALT
ou un centre de réparation
DeWALT
conformément aux codes électriques
nationaux etlocaux.
Mise à la terre électrique :
Le
fait de ne pas faire une mise à la
terre adéquate de ce produit pourrait
résulter en des blessures graves voire
la mort par électrocution. Consulter
les
directives relatives à la mise à la
terre
sous
Installation.
Assurez-vous que le circuit électrique auquel le
compresseur est branché fournit une mise à la
terre électrique adéquate, une tension appropriée
et une bonne protection desfusibles.
AVERTISSEMENT : RISQUE PROVENANT DES
OBJETS PROJETÉS EN L’AIR
CE QUI PEUT SE PRODUIRE COMMENT L’ÉVITER
Le flux d’air comprimé peut
endommager les tissus mous de
la peau exposée et peut projeter
la poussière, des fragments, des
particules détachées et des petits
objets à haute vitesse, ce qui
entraînerait des dommages et des
blessurespersonnelles.
Toujours utiliser de l’équipement de sécurité
homologué : protection oculaire conforme
à la norme ANSI Z87.1 (CAN/CSA Z94.3)
munie d’écrans latéraux lors de l’utilisation
ducompresseur.
Ne jamais pointer une buse ou un pulvérisateur
vers une partie du corps ou vers d’autres
personnes ou desanimaux.
Toujours mettre le compresseur hors tension et
purger la pression du tuyau à air et du réservoir
d’air avant d’effectuer l’entretien, de fixer des
outils ou desaccessoires.
AVERTISSEMENT : ATTENTION SURFACES CHAUDES
CE QUI PEUT SE PRODUIRE COMMENT L’ÉVITER
Toucher à du métal exposé comme
la tête du compresseur ou du moteur,
la tubulure des gaz d’échappement
ou de sortie, peut se solder en de
sérieusesbrûlures.
Ne jamais toucher à des pièces métalliques
exposées sur le compresseur pendant ou
immédiatement après son utilisation. Le
compresseur reste chaud pendant plusieurs
minutes après sonutilisation.
Ne pas toucher ni effectuer des réparations
aux coiffes de protection avant que l’appareil
n’aitrefroidi.
AVERTISSEMENT : RISQUE ASSOCIÉ AUX PIÈCES MOBILES
CE QUI PEUT SE PRODUIRE COMMENT L’ÉVITER
Les pièces mobiles comme une poulie,
un volant ou une courroie peuvent
provoquer de graves blessures si
elles entrent en contact avec vous ou
vosvêtements.
Ne jamais utiliser le compresseur si les protecteurs
ou les couvercles sont endommagés ouretirés.
Tenir les cheveux, les vêtements et les gants
hors de portée des pièces en mouvement. Les
vêtements amples, bijoux ou cheveux longs
peuvent s’enchevêtrer dans les pièces mobiles.
S’éloigner des évents car ces derniers pourraient
camoufler des pièces mobiles.
Utiliser le compresseur avec des
pièces endommagées ou manquantes
ou le réparer sans coiffes de protection
risque de vous exposer à des pièces
mobiles et peut se solder par de
gravesblessures.
Toutes les réparations requises pour ce produit
devraient être effectuées par un centre de
réparation de l’usine
DeWALT
ou un centre de
réparation autorisé
DeWALT
.
AVERTISSEMENT : RISQUE ASSOCIÉ À UTILISATION DANGEREUSE
CE QUI PEUT SE PRODUIRE COMMENT L’ÉVITER
Une utilisation dangereuse de votre
compresseur d’air pourrait provoquer
de graves blessures, voire votre décès
ou celle d’autrespersonnes.
Revoir et comprendre toutes les directives et
les avertissements contenus dans le présent
mode d’emploi.
Se familiariser avec le fonctionnement et les
commandes du compresseur d’air.
Dégager la zone de travail de toutes personnes,
animaux etobstacles.
Tenir les enfants hors de portée du compresseur
d’air en touttemps.
Ne pas utiliser le produit en cas de fatigue ou
sous l’emprise d’alcool ou de drogues. Rester
vigilant en touttemps.
Ne jamais rendre inopérant les fonctionnalités
de sécurité du produit.
• Installer un extincteur dans la zone detravail.
Ne pas utiliser l’appareil lorsqu’il manque des
pièces ou que des pièces sont brisées ou
nonautorisées.
AVERTISSEMENT
: RISQUE DE CHUTE
CE QUI PEUT SE PRODUIRE COMMENT L’ÉVITER
Un compresseur portatif peut tomber
d’une table, d’un établi ou d’un
toit et causer des dommages au
compresseur, ce qui pourrait résulter
en de graves blessures, voire la mort
de l’opérateur.
Toujours faire fonctionner le compresseur alors
qu’il est dans uns position sécuritaire et stable
afin d’empêcher un mouvement accidentel
de l’appareil. Ne jamais faire fonctionner le
compresseur sur un toit ou sur toute autre position
élevée. Utiliser un tuyau d’air supplémentaire pour
atteindre les emplacements enhauteur.
AVERTISSEMENT : RISQUE DE BLESSURE EN SOULEVANT LE PRODUIT
CE QUI PEUT SE PRODUIRE COMMENT L’ÉVITER
Soulever un objet trop lourd peut se
solder par de gravesblessures.
Le compresseur est trop lourd pour être soulevé
par une seule personne. Demander de l’aide avant
de lesoulever.
AVERTISSEMENT
: RISQUE ASSOCIÉ AU BRUIT
CE QUI PEUT SE PRODUIRE COMMENT L’ÉVITER
Dans certaines conditions et selon la
durée d’utilisation, le bruit provoqué
par ce produit peut contribuer à une
perte auditive.
Porter systématiquement une protection
auditive appropriée durant l’utilisation.
CONSERVER CES DIRECTIVES POUR UN
USAGEULTÉRIEUR
Composants (Fig. 1)
A. Mini-interrupteur F. Clapet
B. Manomètre du réservoir d’air G. Soupape de sûreté
C. Manomètre régulé H. Soupape de purge du réservoir d’air
D. Régulateur de pression I. Filtre d’admission d’air
E. Branchements rapides
CARACTÉRISTIQUES (FIG.1)
MINI-INTERRUPTEUR
Mettez cet interrupteur (A) sur la position MARCHE (I) pour démarrer l’appareil et sur ARRÊT
(0) pour couper l’alimentation en fin d’utilisation.
MANOCONTACTEUR
Le manocontacteur démarre automatiquement le moteur lorsque la pression du réservoir
d’air chute sous la pression d’enclenchement réglée en usine. Il arrête le moteur lorsque la
pression du réservoir d’air atteint la pression de déclenchement réglée enusine.
SOUPAPE DE SÛRETÉ
Si le manocontacteur ne met pas hors tension le compresseur d’air à sa pression de
déclenchement réglée, la soupape de sûreté (G) sert de protection contre une pression
élevée en allant à la pression réglée en usine (pression légèrement plus élevée que le réglage
de déclenchement dumanocontacteur).
CLAPET
Lorsque le compresseur d’air fonctionne, le clapet (F) est ouvert, ce qui permet à l’air
comprimé d’entrer dans le réservoir d’air. Lorsque le compresseur d’air atteint la pression
de déclenchement, le clapet se ferme, ce qui permet à la pression d’air de rester dans le
réservoir d’air.
MANOMÈTRE DE RÉSERVOIR
Le manomètre de réservoir (B) indique la pression d’air de réserve dans le réservoir.
MANOMÈTRE DE PRISE DE COURANT
Le manomètre de prise (C) indique la pression d’air disponible du côté de la prise du
régulateur. Cette pression est contrôlée par le régulateur.
RÉGULATEUR
Le régulateur (D) contrôle la pression d'air indiqué sur le manomètre de sortie. Tirez le bouton
et tournez-le dans le sens des aiguilles d'une montre pour augmenter la pression et dans le
sens contraire pour réduire la pression. Une fois que la pression désirée est atteinte, poussez
le bouton pour le verrouiller. The regulated pressure range is 7–150psi.
AVERTISSEMENT : risque d’éclatement. Purger le réservoir d’air quotidiennement. L’eau
se condensera dans le réservoir d’air. Si l’eau n’est pas vidangée, elle corrodera et affaiblira
le réservoir d’air, provoquant ainsi un risque de rupture du réservoir d’air.
CORP DE BRANCHEMENT RAPIDE UNIVERSEL
Le corps de branchement rapide universel (E) accepte les trois styles de prises de
branchement rapide les plus populaires : industrielle, automobile, et ARO. Il suffit tout
simplement d’appuyer une seule fois pour connecter le corps de branchement rapide à la
prise.
ROBINET DE PURGE
Le robinet de purge (H) se trouve à la base du réservoir d’air et est utilisé pour vidanger la
condensation à la fin de chaque utilisation. Consulter le chapitre Vidange du réservoir sous
Entretien.
SYSTÈME DE REFROIDISSEMENT
Ce compresseur contient un système de refroidissement de conception évoluée. Il est tout
à fait normal pour ce ventilateur de souffler de l’air par les orifices d’aération en grandes
quantités. Le système de refroidissement fonctionne lorsque l’air estexpulsé.
POMPE DE COMPRESSEUR D’AIR
La pompe compresse l’air dans le réservoir d’air. L’air de travail n’est pas disponible avant
que le compresseur ait augmenté la pression du réservoir d’air au-dessus de ce qui est
requis à la sortie d’air.
FILTRE D’ADMISSION D’AIR
Le filtre (I) sert à purifier l’air qui ente dans la pompe. Pour que la pompe reçoive un flux
d’air constant propre, froid et sec, le filtre doit toujours être propre et l’entrée d’air doit être
exempte d’obstructions.
PROTECTEUR DE SURCHARGE DU MOTEUR
Le moteur dispose d’un protecteur de surcharge thermique. Si le moteur surchauffe, peu
importe la raison, le protecteur de surcharge met le moteur hors tension. Il faut donner au
moteur le temps de refroidir avant de le redémarrer. Redémarrage :
1. Réglez le mini-interrupteur (A) sur ARRÊT (0) et débranchez l’appareil.
2. Laisser le moteurrefroidir.
3. Brancher le cordon d’alimentation dans le bon réceptacle de circuit dedérivation.
4. Réglez le mini-interrupteur sur la position MARCHE (I).
INSTALLATION
Assemblage
RACCORDEMENT DES TUYAUX
AVERTISSEMENT : risque d’utilisation dangereuse. Saisir fermement le tuyau en main lors
du raccordement ou de la déconnexion pour empêcher un à-coup dutuyau.
1. S’assurer que le manomètre régulé indique 0 psi.
2. Saisir le tuyau au niveau de la prise de branchement rapide et enfoncer la prise dans
le corps de branchement rapide (E). Le coupleur se mettra enplace.
3. Saisir le tuyau et tirer pour s’assurer que le coupleur est bien enplace.
DÉCONNEXION DES TUYAUX
AVERTISSEMENT : risque d’utilisation dangereuse. Saisir fermement le tuyau en main lors
du raccordement ou de la déconnexion pour empêcher un à-coup dutuyau.
1. S’assurer que le manomètre régulé indique 0psi.
2. Retirer le coupleur du corps de branchement rapide pour dégager la prise de
branchement rapide dutuyau.
INSTALLATION DES ROUES (Fig. 4)
1. Insérez le boulon dans la roue et le dispositif de fixation, comme illustré en figure4.
2. Tout en maintenant fermement l’écrou de blocage avec une clé, resserrez soigneusement
le boulon de laroue.
3. Répétez le même processus pour l’autreroue.
INSTALLATION DES PARE-CHOCS (Fig. 5)
1. Insérez le boulon fileté dans l’isolateur et vissez-le dans l’orifice du dispositif de fixation,
comme illustré en figure 5. Resserrez soigneusement leboulon.
2. Répétez le même processus pour l’autre pare-choc.
Directives relatives à la mise à la terre (Fig. 2)
AVERTISSEMENT : risque de choc électrique. Au cas où un court-circuit se
produirait, la mise à la terre réduit le risque de choc électrique en fournissant un fil
d’échappement pour le courant électrique. Le compresseur d’air doit être correctement mis à
laterre.
Le compresseur d’air portatif est muni d’un cordon ayant un fil de mise à terre avec une prise
de mise à la terre.
1. Le cordon qui se fixe et se branche (M) avec cet appareil contient une goupille de mise à
la terre (L). Cette prise DOIT être utilisée avec une prise correctement mise à la terre (K).
IMPORTANT : La prise utilisée doit être installée et mise à la terre en fonction de tous les
codes et de toutes les ordonnances à l’échelle locale.
2. Assurez-vous que la prise utilisée a la même configuration que la fiche mise à la terre.
N’UTILISEZ PAS UNADAPTATEUR.
3. Inspectez la fiche et le cordon avant chaque utilisation. Ne les utilisez pas s’ils présentent
des signes dedommages.
4. Si ces directives sur la mise à la terre ne sont pas entièrement comprises, ou si vous
n’êtes pas certain que le compresseur a correctement été mis à la terre, faites vérifier
l’installation par un électricienqualifié.
DANGER : risque de choc électrique. UNE MISE À LA TERRE INADÉQUATE PEUT
PROVOQUER UN CHOCÉLECTRIQUE.
• Ne modifiez pas la fiche fournie. Si elle ne s’incère pas dans la prise disponible, une
prise adéquate doit être installée par un électricienqualifié.
Les réparations au cordon ou à la fiche DOIVENT être faites par un électricienqualifié.
Rallonges
Si une rallonge doit être utilisée, s'assurer :
d'utiliser une rallonge à trois fils, munie d'une fiche à trois lames avec mise à la terre et
une prise de courant à trois fentes qui accepte la fiche de la rallonge;
• qu'elle est en bon état;
• qu'elle n'excède pas 50 pi (15,2 m);
• que les fils sont d'un calibre minimum de 12 AWG. (La grosseur du fil augmente comme
le numéro de calibre diminue. Les fils de calibre 10 AWG et 8 AWG peuvent également
être utilisés. NE PAS UTILISER UN FIL DE CALIBRE 14 OU 16 AWG.)
AVIS : risque de dégats matériels. L'utilisation d'une rallonge produira une chute de tension
qui entraînera une perte de puissance au moteur ainsi qu'une surchauffe. Au lieu d'utiliser
une rallonge électrique, augmentez plutôt la longueur du boyau d'air en connectant un autre
boyau à l'extrémité. Connectez des boyaux supplémentaires aubesoin.
Protection de la tension et du circuit
Consulter les Exigences en matière de tension et de circuit de dérivation minimales sous
Fiche technique de la pompe/dumoteur.
ATTENTION : risques de surchauffe. Certains compresseurs d’air peuvent fonctionner sur
un circuit de 15 A si les conditions suivantes sont réunies.
L’alimentation en tension doit se conformer au Code électriquenational.
Le circuit n’est pas utilisé pour alimenter d’autres besoins en électricité.
Les rallonges doivent se conformer auxspécifications.
Le circuit est équipé d’un disjoncteur de 15 A au minimum ou d’un fusible à
temporisation de 15 A. REMARQUE : si le compresseur est branché à un circuit
protégé par des fusibles, utiliser seulement des circuits à temporisation. Les fusibles
de temporisation devraient avoir l’inscription « D » au Canada et « T » aux É.-U.
Si une des conditions ci-dessus n’est pas satisfaite, ou si le fonctionnement du compresseur
cause des interruptions du courant électrique, il peut s’avérer nécessaire de faire fonctionner
l’appareil à partir d’un circuit à 20 A. Il n’est pas nécessaire de changer lescordons.
Compatibilité
REMARQUE : Toujours utiliser un filtre de canalisation d’air pour retirer l’humidité et les
vapeurs d’huile lors de la pulvérisation depeinture.
Emplacement
Placer le compresseur d’air dans un endroit propre, sec et bien aéré à au moins 30,5 cm (12 po)
du mur ou d’autres obstructions qui pourraient interférer avec le débit d’air. Tenir le compresseur
à l’écart des endroits poussiéreux et chargés d’émanations. Ces impuretés pourraient boucher
le filtre et les soupapes d’admission et s’y agglutiner, nuisant ainsi au bon fonctionnement du
compresseur d’air.
AVERTISSEMENT : la pompe de compresseur d’air et le déflecteur ont été conçus pour
assurer un refroidissement adéquat. Les ouvertures d’aération sur le compresseur sont
nécessaires pour garder une température de fonctionnement appropriée. Ne placez pas de
chiffons ou d’autres contenants sur les ouvertures ou à proximité de celles-ci.
Placer le compresseur d’air sur une surface plane et s’assurer qu’il repose sur ses pieds de
caoutchouc et ses roulettes
ÉLECTRICITÉ
Consulter toutes les directives de sécurité avant d’utiliser l’appareil. Respecter les directives
de sécurité du cordon d’alimentation le cas échéant. Positionnez systématiquement
l’interrupteur (L) sur ARRÊT (0) avant de retirer la fiche de la prise.
TRANSPORT (FIG. 3)
Lors du transport du compresseur d’air dans un véhicule, une remorque, etc. s’assurer que
le réservoir d’air soit bien purgé et que l’appareil soit bien ancré. Conduire prudemment
pour éviter de basculer l’appareil dans le véhicule. Un basculement risque d’endommager le
compresseur ou les piècescontiguës.
LEVAGE
Toujours soulever l'appareil à deux personnes et utiliser les points de transport (N)
recommandés. NE PAS le lever par la roues ou ledéflecteur.
DÉPLACEMENT
ATENCIÓN : les roues et la poignée n'offrent pas le dégagement, la stabilité ou
l'appui nécessaire pour descendre ou monter des escaliers ou des marches avec
l'appareil. On doit soulever l'appareil ou le pousser le long d'unerampe.
1. Pour ce faire, saisir la poignée du compresseur et l'incliner vers l'arrière sur sesroues.
AVERTISSEMENT : garder les pieds bien ancrés et faire preuve d’une grande prudence
en transportant le compresseur afin d’éviter de perdre l’équilibre.
2. Une fois le compresseur à l'endroit voulu, l'abaisser lentement sur le sol. Toujours
ranger le compresseur en position verticale en l'appuyant sur les amortisseurs et
lesroues.
MODE D’EMPLOI
AVERTISSEMENT : ne pas utiliser cet appareil avant d’avoir lu le mode d’emploi ainsi que
l’intégralité des directives de sécurité, d’utilisation et d’entretien.
Liste de vérification de pré-démarrage (Fig. 1)
1.
Assurez-vous que le mini-interrupteur (A) est sur la position ARRÊT (0).
2. Branchez le cordon d’alimentation dans le bon réceptacle de circuit de dérivation.
Consulter la rubrique Protection de la tension et du circuit sousInstallation.
3. S’assurer que le réservoir d’air soit bien purgé, consulter la rubrique Vidange du
réservoir d’air sousEntretien.
4. S’assurer que la soupape de purge (H) soit fermée.
5. S’assurer que la soupape de sûreté (G) fonctionne correctement, consulter la rubrique
Vérification de la soupape de sûreté sousEntretien.
6. Tirez le bouton du régulateur et tourner le bouton du régulateur (D) en sens antihoraire
jusqu’à fermeture complète. S’assurer que le manomètre régulé indique 0 psi. Poussez
le bouton pour le verrouiller.
7. Fixez le tuyau et les accessoires. NOTE: Toujours utiliser un tuyau d’air de 9,5 mm (3/8
po) ou plus prévu pour une pression de 300psi.
AVERTISSEMENT : risque d’utilisation dangereuse. Saisir fermement le tuyau en main lors
du raccordement ou de la déconnexion pour empêcher un à-coup dutuyau.
AVERTISSEMENT : risque d’utilisation dangereuse. N'utilisez pas les accessoires
endommagés ouportés.
AVERTISSEMENT : risque d’éclatement. Trop de pression d’air cause un risque sérieux
d’éclatement. Vérifiez la pression maximum suggérée par le fabricant pour les outils
pneumatiques et les accessoires. La pression de sortie du régulateur ne doit jamais dépasser
une pression nominalemaximale.
PROCÉDURES DE FONCTIONNEMENT
Démarrage (Fig. 1)
1. Utiliser la Liste de vérification de pré-démarrage sous Mode d’emploi.
2. Poussez le mini-interrupteur sur la position MARCHE (I) et laissez la pression monter
dans le réservoir. Le moteur s’arrête lorsque la pression du réservoir atteint la pression
dedéclenchement.
AVIS : risque de dégats matériels. L’air comprimé de l’appareil pourrait contenir de l’eau
condensée et des brumes d’huile. Ne pas vaporiser de l’air non filtré sur un article que
l’humidité pourrait endommager. Certains outils ou dispositifs pneumatiques pourraient
requérir de l’air filtré. Lire les directives pour l’outil ou le dispositifpneumatique.
3. Régler le régulateur (D) à la valeur souhaitée. Consulter la rubrique Régulateur
sousCaractéristiques.
Arrêt (Fig. 1)
1. Poussez le mini-interrupteur (A) sur la position ARRÊT (0).
REMARQUE : Si l’utilisation du compresseur est terminée, suivre les étapes 2 à6.
REMARQUE : Lorsque l’appareil est éteint, il est normal d’entendre un court sifflement
quand l’air s’échappe.
REMARQUE : Débranchez l’appareil aprèsutilisation.
2. Tirez le bouton du régulateur et tourner le bouton du régulateur (D) en sens antihoraire
jusqu’à fermeture complète. S’assurer que le manomètre régulé indique 0 psi. Poussez
le bouton pour le verrouiller.
3. Retirer le tuyau et l’accessoire.
AVERTISSEMENT : risque d’utilisation dangereuse. Saisir fermement le tuyau en main lors
du raccordement ou de la déconnexion pour empêcher un à-coup dutuyau.
4. Purger le réservoir d’air, consulter la rubrique Purger le réservoir d’air sous Entretien.
S’assurer que le manomètre du réservoir d’air affiche 0psi.
AVERTISSEMENT : risque d’éclatement. Purger le réservoir d’air quotidiennement. L’eau
se condensera dans le réservoir d’air. Si l’eau n’est pas vidangée, elle corrodera et affaiblira
le réservoir d’air, provoquant ainsi un risque de rupture du réservoir d’air.
5. Laisser refroidir lecompresseur.
6. Nettoyer le compresseur d’air avec un chiffon et le ranger dans un endroit sûr sans risque
degel.
ENTRETIEN
Suivre les procédures suivantes lors de l’entretien ou des réparations du compresseur d’air.
1.
Assurez-vous que le mini-interrupteur (A) est sur la position ARRÊT (0).
2. Débrancher le compresseur d’air.
3. Purger le réservoir d’air.
4. Laisser refroidir le compresseur d’air avant de débuter uneréparation.
REMARQUE : Tous les systèmes de compression d’air comprennent des pièces (par ex.,
huile, filtres, séparateurs) qui sont régulièrement remplacées. Ces pièces usées pourraient
contenir des substances contrôlées et doivent être mises au rebut conformément aux lois et
règlements municipaux, provinciaux, territoriaux etfédéraux.
REMARQUE : Noter la position et l’emplacement des pièces au démontage pour faciliter le
remontagesubséquent.
REMARQUE : Toute réparation non décrite dans cette rubrique devrait être exécutée à un
centre de réparation de l’usine
DeWALT
ou un centre de réparation agréé
DeWALT
.
Programme d’entretien
Procédure
Quoti-
dienne
Hebdo-
madaire
Se reporter
à l’étiquette
d’avertissement
sur le réservoir
Vérification de la soupape de sûreté X
Inspecter le filtre à air X
Vidange du réservoir d’air X
Recherche de bruits ou de vibrations inhabituels X
Vérification des fuites d’air X
1
Nettoyage de la partie externe du compresseur X
Mettre le réservoir hors service X
2
1 - Pour trouver des fuites d’air, appliquer une solution d’eau savonneuse autour des joints.
Alors que le compresseur développe la pression et que l’accumulation de pression
cesse, rechercher toute trace de bulles d’air.
2 - Pour plus d’informations, composer le 1-800-4-
DeWALT
(1-800-433-9258).
Vérification de la soupape de sûreté
AVERTISSEMENT : risque d’éclatement. Si la soupape de sûreté ne fonctionne pas
correctement, il peut se produire une surpressurisation, causant ainsi la rupture du réservoir
d’air ou uneexplosion.
AVERTISSEMENT : risque provenant des objets projet. És Toujours utiliser de
l’équipement de sécurité homologué : protection oculaire conforme à la norme ANSI Z87.1
(CAN/CSA Z94.3) munie d’écrans latéraux lors de l’utilisation ducompresseur.
Avant de mettre en marche le compresseur, tirez sur la bague de la soupape de sûreté pour
vous assurer que la soupape fonctionne librement. REMARQUE : il peut être difficile de tirer
sur l’anneau si la pression du réservoir d’air est à 0 psi. Si la soupape est coincée ou ne
fonctionne pas bien, il faut la remplacer par une soupape du même type.
Vidange du réservoir d’air (Fig. 1)
AVERTISSEMENT : risque d’utilisation dangereuse. Risque associé au bruit. Les
réservoirs d’air contiennent de l’air sous haute pression. Éloigner le visage [ANSI Z87.1 (CAN/
CSA Z94.3)] et toutes autres parties du corps de l’orifice de vidange. Porter des lunettes de
sécurité lors de la vidange car il y a risque de projection de débris au visage.
AVERTISSEMENT : risques auditifs. Porter systématiquement une protection auditive
appropriée durant l’utilisation. Sous certaines conditions et suivant la durée d’utilisation, le
bruit émanant de ce produit pourrait contribuer à une perte de l’acuitéauditive.
REMARQUE : Tous les systèmes de compression d’air génèrent des condensats qui
s’accumulent à un point de vidange (par ex., réservoir, filtre, dispositifs de postrefroidissement
ou sécheur). Le condensat contient de l’huile lubrifiante ou des substances contrôlées, ou les
deux, et doivent être éliminés conformément aux lois et règlements municipaux, provinciaux,
territoriaux etfédéraux.
AVERTISSEMENT : risque d’éclatement. Purger le réservoir d’air quotidiennement. L’eau
se condensera dans le réservoir d’air. Si l’eau n’est pas vidangée, elle corrodera et affaiblira
le réservoir d’air, provoquant ainsi un risque de rupture du réservoir d’air.
AVIS : Risque de dégats matériels. Évacuez l'eau le réservoir d'air peut contenir l'huile et se
rouiller qui peut causer destaches.
1.
Assurez-vous que le mini-interrupteur (A) est sur la position ARRÊT (0).
2. Déposer un récipient convenable sous la soupape de purge pour recueillir lesrésidus.
3. Saisir le levier noir de la soupape depurge.
4. Tourner lentement le levier pour purger graduellement l’air duréservoir.
5. Une fois que le manomètre du réservoir affiche 10 psi, tourner complètement le levier en
positionouverte.
6. Fermer la soupape de purge dès la fin de l’opération.
Vérification des éléments du filtre d’air (Fig. 1)
AVERTISSEMENT : surfaces chaudes. Risque de brûlure. Le postrefroidisseur, la tête de
pompe et les pièces contiguës sont très chaudes – ne pas les toucher. Laisser refroidir le
compresseur avant d’effectuer des réparations sur l’appareil.
1.
Assurez-vous que le mini-interrupteur (A) est sur la position ARRÊT (0).
2. Permettez à l'unité de serefroidir.
3. Enlevez la couverture de filtre (J) de labase.
4. Enlevez l'élément de la base defiltre.
5. Placez le nouvel élément en arrière dans la base de filtre. Achetez les pièces de rechange
de votre revendeur local ou centre commercial autorisé. Employez toujours les pièces de
rechangeidentiques.
6. Couverture instantanée de filtre pour filtrer labase.
AVIS: Risque d’utilisation dangereuse. Ne pas utiliser sans le filtre d’admission d’air.
Accessoires
AVERTISSEMENT : L’utilisation de tout autre accessoire non recommandé avec cet outil
pourrait s’avérer dangereuse. Utiliser uniquement des accessoires de classement égal ou
supérieur à celui de la compresseur d’air.
Les accessoires recommandés pour votre outil peuvent être achetés auprès du distributeur
local ou d’un centre de réparation agréé. Si vous avez besoin d’assistance pour trouver un
accessoire pour votre outil, veuillez contacter D
e
WALT Industrial Tool Co., 701 East Joppa Road,
Towson, MD 21286, États-Unis, composer le 1-800-4-D
e
WALT (1-800-433-9258) ou visiter
notre site Web à www.dewalt.com.
Information sur les réparations
Veuillez recueillir les informations suivantes pour tous les appels au Service à la clientèle :
Numéro du modèle ____________ Numéro de série _________________________________
Date et lieu de l’achat _______________________________________________________________
Réparations
Pour assurer la SÉCURITÉ et la FIABILITÉ du produit, les réparations, l’entretien et les
réglages doivent être réalisés par un centre de réparation en usine D
e
WALT, un centre de
réparation agréé D
e
WALT ou par d’autres techniciens qualifiés. Toujours utiliser des pièces de
rechangeidentiques.
Garantie complète d’un (1) an
Les outils industriels de service intensif de D
e
WALT sont garantis pour une période de un (1)
an à partir de la date d’achat. D
e
WALT réparera gratuitement toutes défectuosités provoquées
par un défaut de matériel ou de fabrication. Pour des renseignements relatifs aux réparations
sous garantie, composer le 1-800-4-D
e
WALT (1-800-433-9258). Cette garantie ne s’applique
pas aux accessoires ni aux dommages causés par des réparations réalisées ou tentées par des
tiers. Cette garantie vous accorde des droits légaux spécifiques et il est possible que vous ayez
d’autres droits qui varient d’un État ou d’une province à l’autre.
AMÉRIQUE LATINE : cette garantie ne s’applique pas aux produits vendus en Amérique latine.
Pour ceux-ci, veuillez consulter les informations relatives à la garantie spécifique présente dans
l’emballage, appeler l’entreprise locale ou consulter le site Web pour les informations relatives
à cettegarantie.
REMPLACEMENT GRATUIT DES ÉTIQUETTES D’AVERTISSEMENT (Fig. 4) : si les étiquettes
d’avertissement deviennent illisibles ou sont manquantes, composer le 1-800-4-D
e
WALT
(1-800-433-9258) pour en obtenir le remplacementgratuit.
GLOSSAIRE
CFM : pied cube parminute.
SCFM : pied cube par minute (standard), une unité de mesure dusoufflage.
PSI : livres par pouce carré, une unité de mesure depression.
kPa (kilopascal) : unité de mesure de pression. 1 kilopascal est égal à 1000 pascals.
Codes de certification : les produits portant une ou plusieurs des mentions suivantes (UL
®
,
CUL, CULUS, ETL
®
, CETL, CETLUS) ont été évalués par des laboratoires indépendants
de sécurité certifiés par l'OSHA et répondent aux normes de sécurité applicables.
*UL
®
est une marque de commerce déposée d’Underwriters Laboratories et ETL
®
est une
marque de commerce déposée d’Electrical TestingLaboratories.
Pression d’enclenchement : lorsque le moteur est éteint, la pression du réservoir d’air
chute quand vous continuez à utiliser votre accessoire. Lorsque la pression du réservoir
chute pour atteindre un niveau bas, le moteur se remet en marche automatiquement. La
basse pression à laquelle le moteur se remet en marche automatiquement est appelée
pression d’enclenchement.
Pression de déclenchement : lorsqu’un compresseur d’air est mis sous tension et se
met à fonctionner, la pression d’air dans le réservoir d’air commence à s’accumuler. Une
haute pression s’accumule avant que le moteur se mette automatiquement hors tension en
protégeant votre réservoir d’air d’une pression supérieure à sa capacité. La haute pression
à laquelle le moteur se met hors tension est appelée pression dedéclenchement.
Circuit de dérivation : le circuit qui transporte de l’électricité du panneau électrique à
laprise.
Cycle de travail : cette pompe du compresseur d’air peut fonctionner en continu.
Cependant, pour prolonger la durée de vie de votre compresseur, il est recommandé
de maintenir un cycle de travail de 50 % à 75 % en moyenne, donc que la pompe du
compresseur ne doit pas fonctionner plus de 30 à 45 minutes par heure.
Guide de dépannage
Cette section énumère les défaillances les plus communes, leurs causes et les mesures
correctives. L’opérateur ou le personnel d’entretien peut exécuter certaines mesures
correctives, d’autres exigent l’assistance d’un technicien D
e
WALT qualifié ou dudistributeur.
Problème Code
Pression excessive dans le réservoir d’air - la soupape de sûreté claque ................. 1, 2
Fuites d’air ........................................................................................................................... 3
Fuites d’air dans le réservoir d’air ou dans les soudures du réservoir d’air .................... 4
Fuites d’air entre la tête et la plaque porte-soupapes ...................................................... 5
Fuites d’air à la soupape de sûreté .................................................................................... 6
Cliquetis ................................................................................................................................ 6
Le relevé de pression sur le manomètre réglementé chute
lorsque l’accessoire est utilisé ............................................................................................ 7
Le compresseur ne fournit pas la quantité d’air
requise pour le fonctionnement d’accessoires ..................................... 8, 9, 10, 11, 12, 22
Fuite d’air continuelle au bouton du régulateur ............................................................... 13
Le régulateur ne parvient pas à fermer la sortie d’air ...................................................... 13
Pompe refuse de fonctionner.................................................. 6, 14, 15, 16, 17, 18, 19, 20
Sifflement ............................................................................................................................ 21
Codes de dépannage
CODE CAUSE PROBABLE SOLUTION PROBABLE
1 Le manocontacteur n’éteint
pas le moteur lorsque le
compresseur atteint la pression
de déclenchement
Réglez le mini-interrupteur sur ARRÊT (0), si l’appareil
ne s’éteint pas, contacter un centre de réparation
en usine de D
e
WALT ou un centre de réparation
agrééD
e
WALT.
2 La pression de l’interrupteur de
déclenchement est trop élevée
Communiquer avec un centre de réparation en usine de
D
e
WALT ou un centre de réparation agrééD
e
WALT.
3 Les raccords de tube ne sont
pas assez serrés
Serrer les raccords qui émettent un sifflement de fuite
d’air. Contrôler les raccords avec une solution d’eau
savonneuse. Ne serrez pastrop.
4 Réservoir d’air défectueux Le réservoir d’air doit être remplacé. Ne pas réparer
lafuite.
AVERTISSEMENT : Risque d’éclatement. Ne pas
percer le réservoir d’air, ni le souder ou le modifier de
quelque manière qui soit. Ces interventions l’affaibliront.
Le réservoir risque de rompre ou d’exploser.
5 Joints d’étanchéité fuyants Communiquer avec un centre de réparation en usine de
D
e
WALT ou un centre de réparation agrééD
e
WALT.
6 Soupape de sûreté défectueuse Faites fonctionner la soupape manuellement en tirant
sur la bague. Si la soupape fuit toujours, laremplacer.
7 Le régulateur n’est pas réglé
correctement pour l’accessoire
utilisé
Il est normal que la pression chute lorsqu’un accessoire
est utilisé, ajuster le régulateur comme indiqué sous
Caractéristiques si la pression chutetrop.
REMARQUE : Régler la pression régulée sous des
conditions de travail avec l’utilisation de l’accessoire.
8 Utilisation excessive prolongée
de l’air
Diminuer la quantité d’airutilisée.
9 Le compresseur ne dispose pas
de la capacité adéquate pour
l’utilisation d’accessoires
Vérifier les exigences d’air de l’accessoire. Si elles
sont supérieures au CFM ou à la pression fournie par
le compresseur d’air, un compresseur de plus grande
capacité est requis pour l’utilisation de l’accessoire.
10 Trou dans le tuyau d’air Remplacer le tuyau d’air.
11 Clapet obstrué Communiquer avec un centre de réparation en usine de
D
e
WALT ou un centre de réparation agrééD
e
WALT.
12 Fuites d’air Serrez lesraccords.
13 Le régulateur est endommagé Leremplacer.
14 Le commutateur de protection
de surcharge du moteur a été
déclenché
Consulter la rubrique Surcharge du moteur sous
Caractéristiques. Si la protection de surcharge de moteur
se déclenche fréquemment, Communiquer avec un
centre de réparation en usine de D
e
WALT ou un centre
de réparation agrééD
e
WALT.
15 La pression du réservoir excède
la pression d'enclenchement du
commutateur
Le moteur démarre automatiquement lorsque la pression
du réservoir chute sous la pression d’enclenchement.
16 La rallonge n’a pas la bonne
longueur ou épaisseur
Vérifier la bonne longueur ou épaisseur du cordon.
Consulter la rubrique Rallonges sousInstallation.
17 Raccords électriques lâches Communiquer avec un centre de réparation en usine de
D
e
WALT ou un centre de réparation agrééD
e
WALT.
18 Possibilité d’un moteur Communiquer avec un centre de réparation en usine de
DeWALT
ou un centre de réparation agrééD
e
WALT.
19 Présence de peinture sur les
pièces internes du moteur
Communiquer avec un centre de réparation en usine
de D
e
WALT ou un centre de réparation agréé D
e
WALT.
Ne pas faire fonctionner le compresseur dans une
zone de pulvérisation de peinture. Lire l’avertissement
concernant les vapeursinflammables.
20 Fusible grillé, disjoncteur
déclenché
1. Vérifiez la boîte à fusibles et remplacez les fusibles,
au besoin. Remettre le disjoncteur à zéro . N’utilisez
pas un fusible ou un disjoncteur ayant une
puissance nominale supérieure à ce qui est précisé
pour votre circuit dedérivation.
2. Vérifiez s’il s’agit du bon fusible. Utilisez seulement
des fusiblestemporisés.
3. Vérifiez s’il y a un problème de basse tension et/ou
de mauvaiserallonge.
4. Débranchez les autres appareils électriques du
circuit ou faites fonctionner le compresseur sur son
propre circuit dedérivation.
21 Courroie usée Communiquer avec un centre de réparation en usine de
D
e
WALT ou un centre de réparation agrééD
e
WALT.
22 Filtre d’admission d’air obstrué Nettoyer ou remplacer le filtre d’admission d’air. Ne pas
utiliser le compresseur d’air sans le filtre. Se reporter au
paragraphe relatif au filtre à air de la rubriqueEntretien.
reconocidas por el Estado de California como causantes de cáncer, defectos de nacimiento
u otros problemas reproductivos. Lávese las manos después deutilizarlo.
ADVERTENCIA:
Algunos tipos de polvo contienen sustancias químicas, como el amianto
y el plomo de las pinturas de base plomo, reconocidas por el Estado de California como
causantes de cáncer, defectos de nacimiento u otros problemas.
GUARDE ESTAS INSTRUCCIONES
PELIGRO: RIESGO DE EXPLOSIÓN O INCENDIO
¿QUÉ PUEDE SUCEDER? CÓMO EVITARLO
Es normal que los contactos eléctricos
dentro del motor y el interruptor de presión
produzcanchispas.
Opere siempre el compresor en un área bien
ventilada libre de materiales combustibles, gasolina
o vapores desolventes.
Si las chispas eléctricas del compresor entran
en contacto con vapores inflamables, pueden
encenderse, provocando un incendio o
unaexplosión.
• Si se pulverizan materiales inflamables, ubique
el compresor al menos a 6,1 m (20 pies)
del área de pulverización. Se puede necesitar
mangueraadicional.
• Guarde los materiales inflamables en lugar seguro
lejos delcompresor.
Restringir cualquiera de las aberturas de
ventilación del compresor puede producir un
sobrecalentamiento grave y podría provocar
unincendio.
Nunca coloque objetos contra o sobre la bomba
delcompresor.
Opere el compresor en un lugar abierto con una
distancia de al menos 30,5 cm (12 ") a cualquier
pared u obstrucción que pudiera restringir el flujo
de aire fresco a las aberturas deventilación.
Opere el compresor en un área limpia, seca y bien
ventilada. No opere la unidad dentro de la casa o
en un área muycerrada.
El funcionamiento sin atención de este producto
podría provocar lesiones personales o daños
a la propiedad. Para disminuir el riesgo de
incendio, no permita que el compresor funcione
sin que alguien locontrole.
Permanezca siempre controlando el producto
cuando está enfuncionamiento.
Siempre apague y desenchufe la unidad cuando no
esté enuso.
PELIGRO: RIESGO RESPIRATORIO (ASFIXIA)
¿QUÉ PUEDE SUCEDER? CÓMO EVITARLO
El aire comprimido que sale de su compresor
no es seguro para respirarlo. El flujo de aire
puede contener monóxido de carbono, vapores
tóxicos o partículas sólidas del tanque de aire.
Respirar estos contaminantes puede provocar
lesiones graves o lamuerte.
El aire que se obtiene directamente del compresor
no se debe usar nunca para consumo humano. El
compresor no incluye equipo de seguridad en línea
y filtros adecuados para consumohumano.
La exposición a productos químicos en el
polvo producido por las herramientas eléc-
tricas al lijar, aserrar, esmerilar, taladrar y
otras actividades de la construcción puede
serpeligrosa.
Los materiales pulverizados como pintura,
solventes para pinturas, removedor de pintu-
ra, insecticidas y herbicidas pueden contener
vapores dañinos yvenenos.
Trabaje en un área con buena ventilación cru-
zada. Lea y siga las instrucciones de seguridad
que se proveen en la etiqueta o en la ficha
técnica de los materiales que está utilizando.
Siempre utilice equipamiento de seguridad cer-
tificado: protección respiratoria aprobada por
NIOSH/OSHA o una mascarilla facial adec-
uada diseñada para usar para los fines que
ustedrequiere.
ADVERTENCIA: RIESGO DE EXPLOSIÓN
Tanque de aire: El 26 de febrero de 2002, la Comisión de Seguridad para Productos de Consumo
delos Estados Unidos publicó el Comunicado # 02-108 sobre la seguridad en los tanques de com-
presores de aire:
Los tanques receptores de los compresores de aire no tienen una vida útil infinita. La vida útil del
tanque depende de diversos factores, incluyendo las condiciones de operación, las condiciones
ambientales, la instalación debida del mismo, modificaciones realizadas en el campo y el nivel de
mantenimiento que reciba. Es difícil prever cuál será el efecto exacto de estos factores sobre la vida
útil del tanque receptor deaire.
Si no se siguen procedimientos de mantenimiento debidos, la corrosión interna de la pared interior
del tanque receptor de aire puede causar una ruptura imprevista en el tanque de aire, lo que hará que
el aire presurizado escape con fuerza y repentinamente, pudiendo lesionar alusuario.
El tanque de su compresor de aire debe ser dado de baja al final del año que aparece en la etiqueta
de advertencia de sutanque.
Las siguientes condiciones pueden llevar a debilitar el tanque de aire y ocasionar la explosión vio-
lenta del mismo:
¿QUÉ PUEDE SUCEDER? CÓMO EVITARLO
No drenar correctamente el agua condensada
del tanque de aire, que provoca óxido y adel-
gazamiento del tanque de aire deacero.
Drene el tanque diariamente o luego de cada uso.
Si un tanque de aire presenta una pérdida, reem-
plácelo inmediatamente con un tanque nuevo o
reemplace todo elcompresor.
• Modificaciones o intento de reparación del
tanque deaire.
Nunca perfore, suelde o haga ninguna modifi-
cación al tanque de aire o a sus elementos. Nunca
intente reparar un tanque de aire dañado o con pér-
didas. Reemplácelo con un tanque de airenuevo.
Las modificaciones no autorizadas de la válvula
de seguridad o cualquier otro componente que
controle la presión deltanque.
• El tanque está diseñado para soportar determina-
das presiones de operación. Nunca realice ajustes
ni sustituya piezas para cambiar las presiones de
operación fijadas en lafábrica.
Elementos y accesorios:
Exceder las indicaciones de presión para las
herramientas neumáticas, las pistolas pulveriza-
doras, los accesorios neumáticos, los neumáti-
cos y otros artículos inflables puede hacer que
exploten o revienten, y puede provocar lesio-
nesgraves.
Siga la recomendación del fabricante del equi-
po y nunca exceda el nivel máximo de presión
aceptable para los elementos. Nunca utilice el
compresor para inflar objetos pequeños de baja
presión, tales como juguetes de niños, pelotas de
fútbol o de basquetbol,etc.
Neumáticos:
• El inflado excesivo de los neumáticos podría
causar lesiones graves y daño a la propiedad.
Utilice un medidor de presión de neumáticos
para controlar la presión de éstos antes de cada
uso y mientras los infla; observe el flanco para
ver la presión correcta delneumático.
NOTA: Los tanques de aire, los compresores y el
equipo similar que se usa para inflar neumáticos
pueden llenar neumáticos pequeños como éstos
con mucha rapidez. Ajuste el regulador de presión
en el suministro de aire a un valor que no supere el
de la presión del neumático. Agregue aire en forma
gradual y use con frecuencia el medidor de presión
de neumáticos para evitarinflarlos.
ADVERTENCIA: RIESGO DE DESCARGA ELÉCTRICA
¿QUÉ PUEDE SUCEDER? CÓMO EVITARLO
Su compresor de aire funciona con electricidad.
Como cualquier otro mecanismo que funciona
con electricidad, si no se lo utiliza correctamente
puede provocar descargaseléctricas.
Nunca haga funcionar el compresor al aire
libre cuando está lloviendo o en condiciones
dehumedad.
Nunca haga funcionar el compresor sin las
cubiertas de protección o si estándañadas.
Que personal no calificado intente realizar
reparaciones puede provocar lesiones graves o
muerte porelectrocución.
Cualquier cableado eléctrico o las reparaciones
requeridas para este producto deben ser realizadas
por un
c
entro de servicio de fábrica
DeWALT
o
un centro de mantenimiento autorizado
DeWALT
de acuerdo con los códigos eléctricos nacionales
ylocales.
Puesta a tierra: La no colocación de la
puesta a tierra adecuada para este producto
puede provocar lesiones graves o muerte por
electrocución. Consulte las Instrucciones de
Conexión a tierra enInstalación.
Asegúrese de que el circuito eléctrico al que se
conecta el compresor suministre la conexión a
tierra adecuada, el voltaje adecuado y el fusible de
protecciónadecuado.
ADVERTENCIA: RIESGO DE OBJETOS DESPEDIDOS
¿QUÉ PUEDE SUCEDER? CÓMO EVITARLO
La corriente de aire comprimido puede provocar
lesiones en los tejidos blandos de la piel expu-
esta y puede impulsar suciedad, astillas, partícu-
las sueltas y objetos pequeños a gran velocidad,
que pueden producir daños en la propiedad y
lesionespersonales.
Utilice siempre equipo de seguridad certificado:
anteojos de seguridad ANSI Z87.1 (CAN/CSA
Z94.3) con protección lateral al usar elcompresor.
Nunca apunte ninguna boquilla ni pulverizador a
ninguna parte del cuerpo o a otras personas oani-
males.
Apague siempre el compresor y drene la presión de
la manguera de aire y del tanque de aire antes de
intentar hacer mantenimiento, conectar herramien-
tas oaccesorios.
ADVERTENCIA: RIESGO DE SUPERFICIES CALIENTES
¿QUÉ PUEDE SUCEDER? CÓMO EVITARLO
• Tocar metal expuesto como el cabezal del
compresor, el cabezal del motor, el escape del
motor, o los tubos de salida puede provocar
quemadurasgraves.
• Nunca toque ninguna parte metálica expuesta del
compresor durante o inmediatamente después
de su funcionamiento. El compresor continuará
caliente durante varios minutos después de
sufuncionamiento.
• No toque las cubiertas protectoras ni intente
realizar mantenimiento hasta que la unidad se
hayaenfriado.
ADVERTENCIA: RIESGO POR PIEZAS MÓVILES
¿QUÉ PUEDE SUCEDER? CÓMO EVITARLO
Las piezas móviles como la polea, el volante y
la correa pueden provocar lesiones graves si
entran en contacto con usted o con susropas.
Nunca haga funcionar el compresor sin los protec-
tores o cubiertas o si los mismos estándañados.
Mantenga el cabello, la ropa y los guantes alejados
de las piezas en movimiento. Las ropas holgadas,
las joyas o el cabello largo pueden quedar atrapa-
dos en las piezas móviles.
Los orificios de ventilación pueden cubrir piezas en
movimiento, por lo que también se deben evitar.
Intentar hacer funcionar el compresor con par-
tes dañadas o faltantes, o intentar reparar el
compresor sin las cubiertas protectoras puede
exponerlo a piezas móviles lo que puede provo-
car lesionesgraves.
Cualquier reparación requerida por este producto
debe ser realizada por un centro de servicio
de fábrica
DeWALT
o un centro de servicio
autorizado
DeWALT
.
ADVERTENCIA: RIESGO DE OPERACIÓN INSEGURA
¿QUÉ PUEDE SUCEDER? CÓMO EVITARLO
Definiciones: Normas de seguridad
Las siguientes definiciones describen el nivel de gravedad de cada advertencia. Lea el
manual y preste atención a estossímbolos.
PELIGRO:
Indica una situación de peligro inminente que, si no se evita,
provocará
la
muerte o lesionesgraves.
ADVERTENCIA:
Indica una situación de peligro potencial que, si no se evita,
podría
provocar la
muerte o lesionesgraves.
ATENCIÓN:
Indica una situación de peligro potencial que, si no se evita,
puede
provocar
lesiones leves omoderadas.
AVISO: Se refiere a una práctica no relacionada a lesiones corporales que de no
evitarse puede resultar en daños a lapropiedad.
SI TIENE ALGUNA DUDA O ALGÚN COMENTARIO SOBRE ÉSTA U OTRA HERRAMIENTA
DeWALT
, LLÁMENOS AL NÚMERO GRATUITO: 1-800-4-
DeWALT
(1-800-433-9258)
Instrucciones de seguridad importantes
ADVERTENCIA: No opere esta unidad hasta que haya leído este manual de instrucciones de
seguridad, operación ymantenimiento.
ADVERTENCIA:
Este producto contiene sustancias químicas, incluido el plomo,
Esté en buenascondiciones.
No más largo que 15,2 m (50 pies).
Calibre 12 (AWG) o mayor. (La medida de los cables se incrementa a medida que su
número ordinal decrece. 10 y 8 AWG pueden ser usados también. NO USE 14 NI
16AWG).
AVISO: Riesgo de daño a la propiedad. El uso de cables de extensión eléctrica originará
una caída de tensión, lo que determinará una pérdida de potencia del motor así como su
recalentamiento. En lugar de utilizar un cable de extensión eléctrica, incremente el alcance
de la manguera de aire dentro de la zona de trabajo, añadiéndole otro largo de manguera a
su extremo. Conecte los largos adicionales de manguera de acuerdo a sunecesidad.
Voltaje y protección del circuito
Consulte el voltaje y los requisitos mínimos del circuito de derivación en la sección
Especificaciones.
ATENCIÓN: Existe riesgo de sobrecalentamiento. Ciertos compresores de aire se pueden
operar mediante un circuito de 15 A si se cumplen las siguientes condiciones
El suministro de voltaje al circuito debe cumplir con el Código de ElectricidadNacional.
El circuito no se utiliza para cubrir ninguna otra necesidad deelectricidad.
Los cables prolongadores cumplen con lasespecificaciones.
El circuito está equipado con un disyuntor de 15 A mínimo o un fusible de acción
retardada de 15 A.
NOTA: Si el compresor está conectado a un circuito protegido con fusibles, utilice
únicamente fusibles de acción retardada. Los fusibles de acción retardada deben estar
marcados “D” en Canadá y “T” en EE.UU.
Si no se puede cumplir alguna de las condiciones indicadas anteriormente, o si el funcionamiento
del compresor provoca repetidas interrupciones de energía, puede ser necesario hacerlo
funcionar con un circuito de 20 A. No es necesario cambiar elcable.
Compatibilidad
NOTA: Utilice siempre un filtro de línea de aire para eliminar la humedad y el vapor de aceite al
pulverizarpintura.
Lugar
Coloque el compresor de aire en un área limpia, seca y bien ventilada a una distancia de
al menos 30,5 cm (12 ") de la pared o cualquier obstrucción que interfieran con el flujo de
aire. Mantenga el compresor alejado de áreas que tengan suciedad y/o humo volátil en la
atmósfera. Estas impurezas puedan atascar el filtro de entrada y las válvulas, provocando un
funcionamiento ineficiente.
ADVERTENCIA: La bomba y la cubierta del compresor de aire están diseñadas para
permitir un enfriamiento correcto. Las aberturas de ventilación del compresor son necesarias
para mantener la temperatura de operación correcta. No coloque trapos u otros recipientes
sobre o cerca de estasaberturas.
Coloque el compresor de aire en una superficie plana apoyado sobre las patas y ruedas
degoma.
ELÉCTRICAS
Consulte todas las instrucciones de seguridad antes de utilizar la unidad. Observe las
instrucciones de seguridad del cable prolongador, de ser necesario. Ponga siempre el
interruptor (A) en la posición de apagado (OFF(0)) antes de retirar el enchufe de la toma de
corriente.
TRANSPORTE (FIG. 3)
Al transportar el compresor en un vehículo, remolque, etc., asegúrese de que el tanque se haya
drenado y que la unidad esté asegurada y colocada. Maneje con cuidado para evitar que la
unidad se incline en el vehículo. El compresor o los elementos circundantes se pueden dañar
si el compresor seinclina.
LEVANTAR LA UNIDAD
Utilice siempre dos personas cuando levante la unidad y levántela desde los puntos
recomendados (N). NO LEVANTE tomando la unidad de las ruedas o lacubierta.
TRASLADAR LA UNIDAD
ATENCIÓN: Las ruedas y la agarradera no brindan espacio, estabilidad ni apoyo
adecuados para subir o bajar la unidad por escaleras o escalones. La unidad se debe
levantar, o empujar sobre unarampa.
1. Tome la agarradera del compresor e incline el compresor hacia atrás para que se apoye
en lasruedas.
ADVERTENCIA: Riesgo de operación insegura. Asegure el punto de apoyo adecuado y
tenga precaución al desplazar el compresor de manera que la unidad no se incline ni pierda
elequilibrio.
2. Cuando llegue al lugar deseado, baje lentamente compresor hacia el piso. Siempre
guarde el compresor en posición vertical apoyado sobre protectores de goma
yruedas.
PREPARACIÓN PARA EL USO
ADVERTENCIA: No opere esta unidad hasta que haya leído este manual de instrucciones
de seguridad, operación ymantenimiento.
Lista de control previa a la puesta en marcha (Fig. 1)
1. Asegúrese de que el mini interruptor (A) esté en la posición de apagado (OFF(0)).
2.
Enchufe el cable eléctrico en el receptáculo apropiado del circuito de derivación.
Consulte
Voltaje y protección del circuito en la secciónInstalación.
3. Asegúrese de que el tanque de aire se haya drenado, consulte Drenar el tanque de aire en
la sección Mantenimiento.
4. Asegúrese de que la válvula de drenaje (H) esté cerrada.
5. Asegúrese de que la válvula de seguridad (G) funcione correctamente, consulte Controlar la
válvula de seguridad en la secciónMantenimiento.
6. Tire de la perilla del regulador (D) et gire la perilla en sentido contrario a las agujas del reloj
hasta que esté completamente cerrada. Asegúrese de que el manómetro regulado marque
0 psi. Presione la perilla parabloquearla.
7. Conecte la manguera y los accesorios. NOTA: use siempre una manguera de aire de un
mínimo de 9,5 mm (3/8 ") o mayor con una capacidad nominal de 300psi.
ADVERTENCIA: Riesgo de operación insegura. Sostenga la manguera firmemente con las
manos al instalarla o desconectarla para evitar la desconexión repentina de lamanguera.
ADVERTENCIA: Riesgo de operación insegura. No utilice los accesorios dañados
ousados.
ADVERTENCIA: Riesgo de explosión. Demasiada presión de aire produce peligro de
estallido. Controle el valor nominal máximo de presión del fabricante para las herramientas y los
accesorios neumáticos. La presión de salida del regulador nunca debe exceder el valor máximo
depresión.
PROCEDIMIENTOS OPERATIVOS
Puesta en marcha (Fig. 1)
1. Siga la Lista de control previa a la puesta en marcha en la sección Preparación para
eluso.
2. Mueva el interruptor a la posición de encendido (ON(I)) y deje que aumente la presión del
tanque. El motor se detendrá cuando la presión del tanque alcance la presión decorte.
AVISO:
Riesgo de daño a la propiedad. El aire comprimido de la unidad puede contener
condensación de agua y emanación de aceite. No pulverice aire no filtrado sobre un artículo
que podría dañarse con la humedad. Algunos dispositivos o herramientas neumáticas pueden
requerir aire filtrado. Lea las instrucciones del dispositivo o la herramientaneumática.
3. Ajuste el regulador (D) en la configuración deseada. Consulte el punto Regulador en la
secciónCaracterísticas.
Apagado (Fig. 1)
1. Mueva el mini interruptor (A) a la posición de apagado (OFF(0)).
NOTA: Si terminó de utilizar el compresor, siga los pasos 2a6.
NOTA: Cuando se apagó la unidad, es normal que se escuche un silbido breve que indica la
salida deaire.
NOTA: Desenchufe la unidad de la toma de corriente cuando no esté enuso.
2. Tire de la perilla del regulador (D) et gire en sentido contrario a las agujas del reloj hasta
que esté completamente cerrada. Asegúrese de que el manómetro regulado marque 0 psi.
Presione la perilla parabloquearla.
3. Retire la manguera y losaccesorios.
ADVERTENCIA: Riesgo de operación insegura. Sostenga la manguera firmemente con las
manos al instalarla o desconectarla para evitar la desconexión repentina de lamanguera.
4. Drene el tanque de aire,
consulte Drenar el tanque de aire en la sección Mantenimiento
.
Asegúrese de que el manómetro regulado marque 0psi.
ADVERTENCIA: Riesgo de explosión. Drene el tanque de aire diariamente. El agua se
condensará en el tanque de aire. Si no se drena, el agua corroerá y debilitará al tanque de aire
provocando el riesgo de rotura delmismo.
5. Deje enfriar elcompresor.
6. Limpie el compresor de aire y guárdelo en un área segura, que no secongele.
MANTENIMIENTO
Se deben seguir los siguientes procedimientos cuando se realicen tareas de mantenimiento o
servicio en el compresor deaire.
1.
Asegúrese de que el mini interruptor (A) esté en la posición de apagado (OFF(0)).
2. Retire el enchufe del compresor de aire deltomacorriente.
3. Drene el tanque deaire.
4. Deje enfriar el compresor de aire antes de comenzar las tareas demantenimiento.
NOTA: Todos los sistemas de aire comprimido contienen piezas de mantenimiento (por ejemplo,
aceite, filtros, separadores) que se reemplazan periódicamente. Estas piezas usadas pueden
contener sustancias reguladas y se deben desechar conforme a las leyes y reglamentaciones
locales, estatales yfederales.
NOTA: Tome nota de las posiciones y ubicaciones de las piezas durante el desarmado para
facilitar elreensamblaje.
NOTE: Cualquier tarea de mantenimiento no incluida en esta sección debe ser realizada por un
centro de servicio de fábrica D
e
WALT o un centro de servicio autorizadoD
e
WALT.
Tabla de mantenimiento
Procedimiento
Diaria-
mente
Semanal-
mente
Remítase a la etiqueta de
advertencia del tanque
Controlar la válvula de seguridad
X
Inspeccionar el filtro de aire
X
Drenar el tanque de aire
X
Controlar ruidos o vibraciones inusuales
X
Verificar si hay pérdidas de aire
X
1
Limpiar el exterior del compresor
X
El tanque debe ser dado de baja
X
2
1 - Para verificar si hay pérdidas de aire aplique una solución de agua jabonosa alrededor de las
juntas. Mientras el compresor bombea para generar presión y luego de que la presión se corte,
vea si se forman burbujas deaire.
2 - Para mayor información, llame al 1- 800-4-D
e
WALT (1-800-433-9258)
Controlar la válvula de seguridad
ADVERTENCIA: Riesgo de explosión. Si la válvula de seguridad no trabaja correctamente,
puede haber sobrepresurización, provocando la rotura del tanque de aire o unaexplosión.
ADVERTENCIA:
Riesgo de objetos despedidos.
Utilice siempre equipo de seguridad
certificado: anteojos de seguridad ANSI Z87.1 (CAN/CSA Z94.3) con protección lateral al usar
elcompresor.
Antes de arrancar el compresor, tire del anillo de la válvula de seguridad para asegurarse de que la
válvula de seguridad trabaja libremente. NOTA: Es posible que resulte difícil jalar del anillo cuando la
presión del tanque de aire sea 0 psi. Si la válvula está atascada o no opera con facilidad, se la debe
reemplazar con el mismo tipo de válvula.
La operación insegura de su compresor de aire
podría producir lesiones graves o la muerte, a
usted mismo o a otraspersonas.
Revise y comprenda todas las instrucciones y
advertencias de estemanual.
Familiarícese con la operación y los controles del
compresor deaire.
Mantenga el área de operaciones libre de perso-
nas, mascotas yobstáculos.
Mantenga a los niños alejados del compresor de
aire en todomomento.
No opere el producto cuando esté cansado o bajo
la influencia de alcohol o drogas. Manténgase
alerta en todomomento.
Nunca anule las características de seguridad de
esteproducto.
Equipe el área de operaciones con un extintor
deincendios.
No opere la máquina si faltan piezas, si éstas están
rotas o si no son lasautorizadas.
ADVERTENCIA: RIESGO DE CAÍDAS
¿QUÉ PUEDE SUCEDER? CÓMO EVITARLO
Un compresor portátil se puede caer de una
mesa, banco o techo, provocando daños al
compresor y puede producir lesiones graves o
la muerte deloperador.
• Opere siempre el compresor en una posición
estable y segura para evitar que la unidad se mueva
accidentalmente. Nunca opere el compresor sobre
un techo u otra ubicación elevada. Utilice una
manguera de aire adicional para alcanzar las
ubicacioneselevadas.
ADVERTENCIA: RIESGO DE LESIÓN POR LEVANTAR MUCHO PESO
¿QUÉ PUEDE SUCEDER? CÓMO EVITARLO
El intento de levantar un objeto muy pesado
puede provocar lesionesgraves.
El compresor es demasiado pesado como para
que lo levante una sola persona. Consiga ayuda de
otras personas paralevantarlo.
ADVERTENCIA: RIESGO POR RUIDOS
¿QUÉ PUEDE SUCEDER? CÓMO EVITARLO
En determinadas condiciones y según el período
de uso, el ruido provocado por este producto
puede originar pérdida de audición.
Utilice siempre protección auditiva apropiada
al usar esta herramienta.
CONSERVE ESTAS INSTRUCCIONES
PARA FUTURAS CONSULTAS
Componentes (Fig. 1)
A. Mini interruptor G. Válvula de seguridad
B. Manómetro del tanque de aire H. Válvula de drenaje del
C. Manómetro regulado tanque de aire
D. Regulador de presión I. Filtro de entrada de aire
E. Conectores rápidos
F. Válvula de control
CARACTERÍSTICAS (FIG. 1)
MINI INTERRUPTOR
Ponga este interruptor (A) en la posición de encendido (ON(I)) para poner en marcha la
unidad y en la de apagado (OFF(0)) para desconectar la alimentación al final de cada uso.
INTERRUPTOR DE PRESIÓN
El interruptor de presión arranca automáticamente el motor cuando la presión del tanque de aire
cae por debajo de la presión de arranque fijada en fábrica. Detiene el motor cuando la presión
del tanque de aire alcanza la presión de corte fijada enfábrica.
VÁLVULA DE SEGURIDAD
Si el interruptor de presión no apaga el compresor de aire en su punto de presión de corte, la
válvula de seguridad (G) protegerá contra la presión alta saltando a la presión fijada en fábrica
(ligeramente mayor que la fijada para el corte del interruptor depresión).
VÁLVULA DE CONTROL
Cuando el compresor de aire está funcionando, la válvula de control (F) está abierta, permitiendo
al aire comprimido entrar al tanque de aire. Cuando el compresor de aire alcanza la presión de
corte, la válvula de control se cierra, permitiendo que la presión de aire se conserve dentro del
tanque deaire.
MANÓMETRO (MEDIDOR DE PRESIÓN) DEL TANQUE
El manómetro (medidor de presión) del tanque (B) indica la presión de aire de reserva en el
tanque.
MANÓMETRO (MEDIDOR DE PRESIÓN) DE SALIDA
El manómetro (medidor de presión) de salida (C) indica la presión del aire disponible en la salida
del regulador. Esta presión la controla el regulador.
REGULADOR
La regulador (D) controla la presión de aire mostrada en el manómetro de salida. Tire de la
perilla y gírela en sentido horario para incrementar la presión, y hágalo en sentido inverso
para disminuirla. Cuando se logre la presión deseada, presione la perilla para bloquearla. The
regulated pressure range is 7–150psi.
ADVERTENCIA: Riesgo de explosión. Demasiada presión de aire produce peligro de
estallido. Controle el valor nominal máximo de presión del fabricante para las herramientas y los
accesorios neumáticos. La presión de salida del regulador nunca debe exceder el valor máximo
depresión.
CONECTORE RÁPIDO UNIVERSALE
El conector rápido universal (E) acepta los tres estilos más populares de enchufes de
conexión rápida: Industrial, para automóviles y ARO. “Empujar para conectar” con una
sola mano, esta operación hace que las conexiones sean más simples y fáciles. Los dos
conectores rápidos permiten la utilización de dos herramientas al mismotiempo.
VÁLVULA DE DRENAJE
La válvula de drenaje (H) está ubicada en la base del tanque de aire y se utiliza para drenar la
condensación al terminar cada etapa de uso.
Consulte Drenar el tanque de aire en la sección
Mantenimiento.
SISTEMA DE ENFRIAMIENTO
Este compresor tiene un sistema de enfriamiento de diseño avanzado. Es normal que este
ventilador sople aire a través de los orificios de ventilación en cantidades importantes. El
sistema de enfriamiento está funcionando cuando se expulsaaire.
BOMBA DEL COMPRESOR DE AIRE
La bomba comprime el aire en el tanque de aire. No hay aire para trabajar hasta que el
compresor no ha elevado la presión del tanque de aire por encima de la requerida en la salida
deaire.
FILTRO DE ENTRADA DE AIRE
El filtro (I) está diseñado para limpiar el aire que ingresa a la bomba. Para asegurar que la
bomba reciba continuamente un suministro de aire limpio, fresco y seco, el filtro debe estar
siempre limpio y la entrada del filtro libre deobstrucciones.
PROTECTOR DE SOBRECARGA DEL MOTOR
El motor tiene un protector de sobrecarga térmica. Si el motor se recalienta por alguna razón,
el protector de sobrecarga apagará el motor. Se debe permitir que el motor se enfríe antes
de volver a encenderlo. Para volver a encenderlo:
1. Ponga el mini interruptor (A) en apagado (OFF(0)) y desenchufe la unidad.
2. Espere que el motor seenfríe.
3. Enchufe el cable eléctrico en el receptáculo apropiado del circuito dederivación.
4. Ponga el mini interruptor en la posición de encendido (ON(I)).
INSTALACIÓN
Ensamblaje
INSTALACIÓN DE LAS MANGUERAS
ADVERTENCIA: Riesgo de operación insegura. Sostenga la manguera firmemente con las
manos al instalarla o desconectarla para evitar la desconexión repentina de lamanguera.
1. Asegúrese de que el manómetro regulado marque 0 psi.
2. Tome la manguera por el enchufe de conexión rápida y empuje el enchufe en el conector
rápido (E). El acople quedará en la posicióncorrecta.
3. Tome la manguera y tire de ella para asegurarse de que el acople esté biencolocado.
DESCONEXIÓN DE LAS MANGUERAS
ADVERTENCIA: Riesgo de operación insegura. Sostenga la manguera firmemente con las
manos al instalarla o desconectarla para evitar la desconexión repentina de lamanguera.
1. Asegúrese de que el manómetro regulado marque 0 psi.
2. Del conector rápido, tire el acople hacia atrás para liberar el enchufe de conexión rápida de
lamanguera.
MONTAJE DE LAS RUEDAS (FIG.4)
1. Introduzca el perno a través de la rueda y el soporte como se muestra en la Fig.4.
2. Sujetando la tuerca de fijación en su sitio con una llave, ajuste el perno de la ruedafirme-
mente.
3. Repita estos pasos para la ruedaopuesta.
MONTAJE DE LOS TOPES (FIG.5)
1. Introduzca el perno roscado a través del aislador y enrósquelo en el orificio del soporte,
como se muestra en la Fig. 5. Ajuste bien elperno.
2. Repita estos pasos para el topeopuesto.
Instrucciones de conexión a tierra (Fig. 2)
ADVERTENCIA: Riesgo de descarga eléctrica. En el caso de cortocircuito, la puesta a tierra
reduce el riesgo de descarga eléctrica al proveer un cable de escape para la corriente eléctrica.
Este compresor de aire debe estar correctamente conectado atierra.
El compresor de aire portátil está equipado con un cable que tiene un cable a tierra con el
enchufe a tierra apropiado.
1. El juego de cable y enchufe (M) de esta unidad tiene una pata a tierra (L). Este enchufe SE
DEBE usar con un tomacorriente con puesta a tierra (K).
IMPORTANTE: El tomacorriente que se utiliza debe estar instalado y puesto a tierra de acuerdo
con todos los códigos y ordenanzas locales.
2. Asegúrese de que el tomacorriente que se utiliza tenga la misma configuración que el
enchufe a tierra. NO UTILICE UNADAPTADOR.
3. Inspeccione el enchufe y el cable cada vez que vaya a utilizarlo. No lo utilice si hay señales
dedaño.
4. Si no se comprenden completamente estas instrucciones de puesta a tierra, o si tiene
dudas sobre si el compresor está puesto a tierra correctamente, haga que un electricista
calificado controle lainstalación.
PELIGRO: Riesgo de descarga eléctrica. UNA PUESTA A TIERRA INCORRECTA PUEDE
PROVOCAR UNA DESCARGAELÉCTRICA.
No modifique el enchufe provisto. Si no coincide con el tomacorriente disponible, un
electricista calificado debe instalar un tomacorrienteapropiado.
Las reparaciones del cable o del enchufe deben ser realizadas por un electricistacalificado.
Cables prolongadores
Si - no obstante - debe utilizarse una extensión de cable, asegúrese de que:
• La extensión eléctrica de 3 conductores, tenga un enchufe de conexión a tierra de
3hojas, y que exista un receptáculo que acepte el enchufe delproducto.
Drenar el tanque de aire (Fig. 1)
ADVERTENCIA: Riesgo de operación insegura. Riesgo por ruidos. Los tanques de aire
contienen aire de alta presión. Mantenga la cara y otras partes del cuerpo lejos de la salida
del drenaje. Utilice
anteojos de seguridad
[ANSI Z87.1 (CAN/CSA Z94.3)], ya que al drenar se
pueden desprender residuos hacia la cara.
ADVERTENCIA: Riesgo de ruido excesivo. Utilice siempre protección auditiva apropiada
al usar esta herramienta. Bajo algunas condiciones y duraciones de uso, el ruido producido
por este producto puede contribuir a la pérdidaauditiva.
NOTA: Todos los sistemas de aire comprimido generan condensación que se acumula en
cualquier punto de drenaje (por ejemplo, tanques, filtro, posenfriadores, secadores). Esta
condensación contiene aceite lubricante y/o sustancias que pueden estar reguladas y que
se deben desechar conforme a las leyes y reglamentaciones locales, estatales yfederales.
ADVERTENCIA: Riesgo de explosión. Drene el tanque de aire diariamente. El agua se
condensará en el tanque de aire. Si no se drena, el agua corroerá y debilitará al tanque de aire
provocando el riesgo de rotura delmismo.
AVISO:
Riesgo de daño a la propiedad. Drene el agua del tanque de aire puede contener aceite
y óxido, lo que puede provocarmanchas.
1.
Asegúrese de que el mini interruptor (A) esté en la posición de apagado (OFF(0)).
2. Coloque un recipiente adecuado debajo de la válvula de drenaje (H) para recoger
ladescarga.
3. Tome el palanca estriado de la válvula dedrenaje.
4. Gire lentamente el palanca para descargar aire del tanque de aire en formagradual.
5. Cuando el manómetro del tanque de aire marque 10 psi, gire la válvula hasta la posición
de completamenteabierta.
6. Cierre la válvula de drenaje cuandotermine.
Controlar el elemento del filtro de aire (Fig. 1)
ADVERTENCIA: S
uperficies calientes.
Riesgo de superficies calientes.
El tubo de enchufe,
cabeza de la bomba, y las piezas circundantes son muy calientes, no toca. Permita que el
compresor se refresque antes delmantenimiento.
1.
Asegúrese de que el mini interruptor (A) esté en la posición de apagado (OFF(0)).
2. Permita que la unidad sefrío.
3. Retire la cubierta del filtro (J) debase.
4. Retire el elemento de base delfiltro.
5. Ponga el nuevo elemento detrás en base del filtro. Compre las piezas de recambio
de su distribuidor local o centro de servicio autorizado. Utilice siempre las piezas de
recambioidénticas.
6. Cubierta rápida del filtro para filtrar labase.
AVISO:
Riesgo de operación insegura. No opere la unidad sin el filtro de entrada deaire.
Accesorios
ADVERTENCIA: El uso de accesorios no recomendados para utilizar con esta herramienta
puede resultar peligroso. Use solamente accesorios con una capacidad nominal igual o
superior a la de la compresor deaire.
Los accesorios que se recomiendan para la herramienta están disponibles para la compra
en su distribuidor local o en el centro de mantenimiento autorizado. Si necesita ayuda para
localizar algún accesorio para su herramienta, comuníquese con D
e
WALT Industrial Tool Co.,
701 East Joppa Road, Towson, MD 21286, llame al 1-800-4-D
e
WALT (1-800-433-9258) o
visite nuestro sitio Web www. dewalt. com.
Información del servicio técnico
Tenga a mano la siguiente información cuando llame al mantenimiento:
Número del modelo ____________________ Número de serie ___________________
Fecha y lugar de compra ____________________________
Reparaciones
Para asegurar la SEGURIDAD y la CONFIABILIDAD del producto, las reparaciones, el
mantenimiento y los ajustes deben ser realizados por un centro de servicio de fábrica
D
e
WALT, un centro de servicio autorizado D
e
WALT u otro personal de mantenimiento
calificado. Utilice siempre piezas de repuestoidénticas.
Póliza de Garantía
IDENTIFICACIÓN DEL PRODUCTO:
Sello o firma delDistribuidor.
Nombre del producto: _____________ Mod./Cat.: _____________ Marca: __________
Núm. de serie:__________ (Datos para ser llenados por el distribuidor)
Fecha de compra y/o entrega del producto: __________________
Nombre y domicilio del distribuidor donde se adquirió el producto: ______________________
__________________________________________________________________________________
Este producto está garantizado por un año a partir de la fecha de entrega, contra
cualquier defecto en su funcionamiento, así como en materiales y mano de obra empleados
para su fabricación. Nuestra garantía incluye la reparación o reposición del producto y/o
componentes sin cargo alguno para el cliente, incluyendo mano de obra, así como los gastos
de transportación razonablemente erogados derivados del cumplimiento de estecertificado.
Para hacer efectiva esta garantía deberá presentar su herramienta y esta póliza sellada por
el establecimiento comercial donde se adquirió el producto, de no contar con ésta, bastará
la factura decompra.
EXCEPCIONES.
Esta garantía no será válida en los siguientes casos:
Cuando el producto se hubiese utilizado en condiciones distintas a las normales;
Cuando el producto no hubiese sido operado de acuerdo con el instructivo de uso que
se acompaña;
Cuando el producto hubiese sido alterado o reparado por personas distintas a las
enlistadas al final de estecertificado.
Anexo encontrará una relación de sucursales de servicio de fábrica, centros de servicio
autorizados y franquiciados en la República Mexicana, donde podrá hacer efectiva su
garantía y adquirir partes, refacciones y accesoriosoriginales.
Garantía completa de un año
Las herramientas industriales D
e
WALT para trabajo pesado tienen garantía de un año a
partir de la fecha de compra. Repararemos, sin cargo, cualquier defecto debido a fallas en
los materiales o la mano de obra. Para obtener información sobre las reparaciones cubiertas
por la garantía, llame al 1-800-4-D
e
WALT (1-800-433-9258). Esta garantía no se extiende a
los accesorios o a los daños causados por terceros al intentar realizar reparaciones. Esta
garantía le concede derechos legales específicos; usted goza también de otros derechos
que varían según el estado oprovincia.
AMÉRICA LATINA: Esta garantía no se aplica a los productos que se venden en América
Latina. Para los productos que se venden en América Latina, debe consultar la información
de la garantía específica del país que viene en el empaque, llamar a la compañía local o
visitar el sitio Web a fin de obtener esainformación.
REEMPLAZO GRATUITO DE LAS ETIQUETAS DE ADVERTENCIA (Fig. 4): Si sus
etiquetas de advertencia se tornan ilegibles o faltan, llame al 1-800-4-D
e
WALT (1-800-433-
9258) para que se le reemplacengratuitamente.
PARA REPARACIÓN Y SERVICIO DE SUS
HERRAMIENTAS ELÉCTRICAS, FAVOR DE DIRIGIRSE
AL CENTRO DE SERVICIO MÁS CERCANO
CULIACAN, SIN
Blvd.Emiliano Zapata 5400-1 Poniente
Col. San Rafael (667) 717 89 99
GUADALAJARA, JAL
Av. La Paz #1779 - Col. Americana Sector Juárez (33) 3825 6978
MEXICO, D.F.
Eje Central Lázaro Cárdenas No. 18
Local D, Col. Obrera (55) 5588 9377
MERIDA, YUC
Calle 63 #459-A - Col. Centro (999) 928 5038
MONTERREY, N.L.
Av. Francisco I. Madero 831 Poniente - Col. Centro (818) 375 23 13
PUEBLA, PUE
17 Norte #205 - Col. Centro (222) 246 3714
QUERETARO, QRO
Av. San Roque 274 - Col. San Gregorio (442) 2 17 63 14
SAN LUIS POTOSI, SLP
Av. Universidad 1525 - Col. San Luis (444) 814 2383
TORREON, COAH
Blvd. Independencia, 96 Pte. - Col. Centro (871) 716 5265
VERACRUZ, VER
Prolongación Díaz Mirón #4280 - Col. Remes (229) 921 7016
VILLAHERMOSA, TAB
Constitución 516-A - Col. Centro (993) 312 5111
PARA OTRAS LOCALIDADES:
Si se encuentra en México, por favor llame al (55) 5326 7100
Si se encuentra en U.S., por favor llame al
1-800-433-9258 (1-800 4-
DeWALT
)
Para servicio y ventas consulte
“HERRAMIENTAS ELECTRICAS”
en la secciónamarilla.
SOLAMENTE PARA PROPÓSITO DE MÉXICO:
IMPORTADO POR: D
e
WALT S.A. DE C.V.
BOSQUES DE CIDROS, ACCESO RADIATAS NO.42
3A. SECCIÓN DE BOSQUES DE LAS LOMAS
DELEGACIÓN CUAJIMALPA,
05120, MÉXICO, D.F.
TEL. (52) 555-326-7100
R.F.C.: BDE810626-1W7
GLOSARIO
CFM: Pies cúbicos porminuto.
SCFM: Pies cúbicos estándar por minuto; unidad de medida de suministro deaire.
PSI: Libras por pulgada cuadrada; una unidad de medida depresión.
kPa (kilopascal): Medición métrica de la presión. 1 kilopascal es equivalente a 1000pascales.
Código de certificación: Los productos que usan una o más de las siguientes marcas: UL
®
,
CUL, CULUS, ETL
®
, CETL, CETLUS, han sido evaluados por OSHA, laboratorios indepen-
dientes certificados en seguridad, y reúnen los estándares suscriptos por a la certificación
de la seguridad.
*UL
®
es una marca registrada de Underwriters Laboratories y ETL
®
es una marca registrada
de Electrical TestingLaboratories.
Presión de arranque: Mientras el motor está apagado, la presión del tanque de aire cae
cuando utiliza un accesorio. Cuando la presión del tanque baja a determinado nivel el motor
volverá a encenderse automáticamente. La presión baja en la cual el motor se vuelve a
encender automáticamente se llama presión dearranque.
Presión de corte: Cuando se enciende o cuando comienza a funcionar un compresor de
aire, comienza a elevarse la presión del aire en el tanque de aire. Se eleva hasta determinada
presión antes de que el motor se apague automáticamente, protegiendo a su tanque de aire
de una presión de aire mayor a su capacidad. La presión alta en la cual el motor se apaga
se llama presión decorte.
Circuito de derivación: Es el circuito que lleva electricidad del tablero eléctrico
altomacorriente.
Factor de trabajo: Esta bomba del compresor de aire puede funcionar en forma continua.
Sin embargo, para prolongar la vida útil del compresor de aire, se recomienda que se
mantenga un promedio entre un 50% y un 75% de factor de trabajo, por lo que la bomba
del compresor de aire no debe funcionar más de 30 a 45 minutos en una hora dada.
Guía de detección de problemas
Esta sección proporciona una lista de las fallas que se presentan con mayor frecuencia, sus
causas y las medidas correctivas correspondientes. El operador o el personal de mantenimiento
pueden llevar a cabo algunas de estas acciones correctivas, pero es posible que otras necesiten
la asistencia de un técnico
DeWALT
calificado o de sudistribuidor.
Problema Código
Presión excesiva en el tanque de aire: la válvula de seguridad salta .........................1, 2
Pérdidas de aire .................................................................................................................. 3
Pérdidas de aire en el tanque de aire o en las soldaduras del tanque de aire ..............4
Pérdidas de aire entre el cabezal y la placa de la válvula .................................................5
Pérdidas de aire de la válvula de seguridad ......................................................................6
Ruido de golpeteo ...............................................................................................................6
La lectura de la presión en el manómetro regulado cae cuando se usa un accesorio .. 7
El compresor no suministra suficiente aire
para operar los accesorios .....................................................................8, 9, 10, 11, 12, 22
La perilla del regulador tiene una pérdida constante de aire ..........................................13
El regulador no cierra la salida de aire .............................................................................13
El motor no funciona .....................................................6, 14, 15, 16, 17, 18, 19, 20
Sonidos agudos ................................................................................................................. 21
Códigos de detección de problemas
CÓDIGO CAUSA POSIBLE SOLUCIÓN POSIBLE
1 El interruptor de presión
no apaga el motor
cuando el compresor
alcanza la presión
decorte.
Ponga el mini interruptor en apagado (OFF(0)), si la unidad no
se apaga comuníquese con un c
e
ntro de servicio de fábrica
DeWALT
o con un c
e
ntro de servicio autorizado
DeWALT
.
2 El valor de corte del
interruptor de presión es
demasiado alto
Comuníquese con un centro de servicio de fábrica D
e
WALT o
con un centro de servicio autorizadoD
e
WALT.
3 Las conexiones de
los tubos no están
bienajustadas.
Ajuste las conexiones en los lugares donde sienta escapes
de aire. Controle las conexiones con una solución de agua
jabonosa. No ajustedemasiado.
4 Tanque de aire defectuoso Se debe reemplazar el tanque de aire. No repare lapérdida.
ADVERTENCIA: Riesgo de explosión. No perfore, suelde
ni modifique el tanque de aire o el mismo se debilitará. El
tanque de aire se puede romper oexplotar.
5 Sellos de pérdidas Comuníquese con un centro de servicio de fábrica D
e
WALT o
con un centro de servicio autorizadoD
e
WALT.
6 Válvula de seguridad
defectuosa
Opere la válvula de seguridad manualmente tirando del anillo.
Si la válvula aún pierde, debe serreemplazada.
7 El regulador no está
correctamente ajustado
para el uso de un
accesorio
Es normal que se presente alguna caída de presión cuando
se usa un accesorio, ajuste el regulador como se indica
en Regulador en la sección Características si la caída
esexcesiva.
NOTA: Ajuste la presión regulada bajo condiciones de flujo
mientras se usa elaccesorio.
8 Uso excesivo y
prolongado de aire
Disminuya el uso deaire.
9 El compresor no es lo
suficientemente grande
para el accesorio
Controle los requisitos de aire del accesorio. Si es mayor que
el flujo de aire o la presión provista por su compresor de aire,
necesita un compresor más grande para operar elaccesorio.
10 Agujero en la manguera
de aire
Reemplace la manguera deaire.
11 Válvula de control
restringida
Comuníquese con un centro de servicio de fábrica D
e
WALT o
con un centro de servicio autorizadoD
e
WALT.
12 Pérdidas de aire Ajuste lasconexiones.
13 El regulador está dañado Reemplácelo
14 Se activó el interruptor de
sobrecarga del motor
Consulte Sobrecarga del motor en la sección Características.
Si la protección de la sobrecarga del motor dispara con
frecuencia, comuníquese con un centro de servicio de fábrica
D
e
WALT o con un centro de servicio autorizadoD
e
WALT.
15 La presión del tanque
excede la presión de
arranque del interruptor
de presión
El motor arrancará en forma automática cuando la presión del
tanque descienda por debajo de la presión de arranque del
interruptor depresión.
16 El cable prolongador
es de longitud o calibre
incorrectos
Verifique el calibre del conductor y la longitud del cable
adecuados. Consulte Cables prolongadores en la
secciónInstalación.
17 Conexiones eléctricas
flojas
Comuníquese con un centro de servicio de fábrica D
e
WALT o
con un centro de servicio autorizadoD
e
WALT.
18 Posible motor
defectuosos
Comuníquese con un centro de servicio de fábrica D
e
WALT o
con un centro de servicio autorizadoD
e
WALT.
19 Piezas internas del motor
salpicadas con pintura
Comuníquese con un centro de servicio de fábrica D
e
WALT
o con un centro de servicio autorizado D
e
WALT. No opere
el compresor en la zona salpicada con pintura. Consulte la
advertencia sobre vaporinflamable.
20 Fusible quemado,
interruptor automático
activado
1. Controle si hay algún fusible quemado en la caja
de fusibles y reemplácelo de ser necesario. Reinicie
el interruptor automático. No utilice un fusible o un
interruptor automático de valor mayor al especificado para
su circuito de derivación enparticular.
2. Verifique si el fusible es correcto. Utilice solamente un
fusible de acciónretardada.
3. Verifique si hay bajo voltaje y/o si el cable prolongador es
eladecuado.
4. Desconecte los otros artefactos eléctricos del circuito u
opere el compresor sobre su propio circuito dederivación.
21 Correa desgastada Comuníquese con un centro de servicio de fábrica D
e
WALT o
con un centro de servicio autorizadoD
e
WALT.
22
Filtro de entrada de aire
restringida
Limpie o reemplace el filtro de entrada de aire. No haga
funcionar al compresor sin el filtro. Consulte el párrafo Filtro
de aire en la secciónMantenimiento.
Specifications/ Fiche technique/ Especificaciones
MODEL/ MODÈLE/ MODELO D55168
WEIGHT/ POIDS/ PESO 105 lbs. (47.6 kg)/ 47,6 kg (105 lbs.)/ 47,6 kg (105 libras)
HEIGHT/ HAUTEUR/ ALTURA 41.75" (1060.5 mm)/ 1060,5 mm (41,75 po)/ 1060,5 mm (41,75")
WIDTH/ LARGEUR/ ANCHO 19,0" (482.6 mm)/ 482,6 mm (19,0 po)/ 482,6 mm (19,0 ")
LENGTH/ LONGUEUR/ LONGITUD 21.25" (539.8 mm)/ 539,8 mm (21,25 po)/ 539,8 mm (21,25 ")
AIR TANK CAPACITY/ CAPACITÉ DU RÉSERVOIR D’AIR/ CAPACIDAD DEL TANQUE DE AIRE 15 Gallon (56.8 liters)/ 56.8 liters (15 gallons)/ 56.8 L (15 galones)
APPROX CUT-IN PRESSURE/
PRESSION D’ENCLENCHEMENT APPROX./ PRESIÓN DE ARRANQUE APROXIMADA
180 psi/ 180 psi/ 180 psi
APPROX. CUT-OUT PRESSURE/
ENV. PRESSION DE DÉCLENCHEMENT/ PRESIÓN DE CORTEAPROX.
225 psi/ 225 psi/ 225 psi
SCFM @ 90 PSI/ PI
3
/MIN STANDARD À 90 PSI/ SCFM A 90 PSI
5.0 */ 5,0 */ 5,0 *
NOISE LEVEL/ NIVEAU SONORE/ NIVEL DE RUIDO 78 dBA
+
/ 78,0 dBA
+
/ 78,0 dBA
+
VOLTAGE/ TENSION/ VOLTAJE Single 120V/ monophasé, 120V/ 120V, una sola fase
MINIMUM BRANCH CIRCUIT REQUIREMENT/ EXIGENCE MINIMALE DU CIRCUIT DE DÉRIVATION/ REQUISITO
MÍNIMO PARA EL CIRCUITO DE DERIVACIÓN:
15 A/ 15 A/ 15 A
FUSE TYPE/ TYPE DE FUSIBLE/ FUSIBLE DE TIPO Time delay/ temporisation/ acción retardada
REGULATED PRESSURE RATING (APPROXIMATE) / PRESSION NOMINALE STABILISÉE (APPROXIMATIVE)/
CLASIFICACIÓN DE PRESIÓN REGULADA (APROXIMADAMENTE)
3–150 psi/ 3–150 psi/ 3 a 150 psi
QUICK CONNECT TYPE/ TYPE DE RACCORD À CONNEXION RAPIDE/ TIPO DE CONEXIÓN RÁPIDA 1/4" (6.4 mm) Industrial/ 6,4 mm (1/4po.) Industriel/ 6,4 mm
(1/4") Industrial
*Tested per ISO 1217:1996/ Testé conformément à la norme ISO 1217:1996/Probado según la norma ISO 1217:1996
+
Tested per ISO 3744:1994/ Testé conformément à la norme ISO 3744:1994/Probado según la norma ISO 3744:1994
Declared Noise Emission Values
per ISO 3744
NOISE EMISSION VALUES
Sound Pressure Level: LpA = 78.0 dBA re 20μPA
Uncertainty in the Sound
Pressure Level: KpA = 3.0 dBA re 20μPA
Sound Power Level: LwA = 92.0 dBA re 1 pw
Uncertainty in the Sound
Power Level: KwA = 3.0 dBA re 1 pw
The sum of the emission value and the uncertainty is
the limit below which there is a 95% confidence the
value of a single tool will lie below when the tool is new.
Valeurs de l’émission de bruits
déclarées en conformité
avec l’ISO 3744
VALEUR DE L’ÉMISSION DE BRUITS
Niveau de pression
acoustique : LpA = 78,0 dBA re 20μPA
Incertitude du niveau
de pression acoustique
calculé : KpA = 3,0 dBA re 20μPA
Niveau de puissance
acoustique : LwA = 92,0 dBA re 1 pw
Incertitude du niveau de
puissance acoustique : KwA = 3,0 dBA re 1 pw
La somme de la valeur de l’émission et de l’incertitude
établit la limite sous laquelle la valeur pour un seul outil
y sera inférieure et ce, à 95 % de fiabilitéstatistique.
Valores de emisión de ruido
declarados según ISO 3744
VÁLVULAS DE EMISIÓN DE RUIDO
Nivel de presión del
sonido: LpA = 78,0 dBA re 20μPA
Incertidumbre en el nivel
de presión del sonido: KpA = 3,0 dBA re 20μPA
Nivel de potencia del
sonido: LwA = 92,0 dBA re 1 pw
Incertidumbre en el nivel
de potencia del sonido: KwA = 3,0 dBA re 1 pw
La suma del valor de emisión y de la incertidumbre es
el límite debajo del cual hay un porcentaje de confianza
del 95% de que estará el valor de una herramienta
cuando la herramienta esnueva.

Transcripción de documentos

INSTRUCTIVO DE OPERACIÓN, CENTROS DE SERVICIO Y PÓLIZA DE GARANTÍA. ADVERTENCIA: LÉASE ESTE INSTRUCTIVO ANTES DE USAR EL PRODUCTO. WARNING: RISK OF ELECTRICAL SHOCK WHAT CAN HAPPEN HOW TO PREVENT IT • Your air compressor is powered by • Never operate the compressor outdoors when electricity. Like any other electrically it is raining or in wet conditions. powered device, If it is not used properly • Never operate compressor with protective it may cause electric shock. covers removed or damaged. D55168 Oil Free Portable Air Compressor Compresseur d’air portatif sans huile Compresor de aire sin aceite portátil • Repairs attempted by unqualified • Any electrical wiring or repairs required on this personnel can result in serious injury or product should be performed by a DeWALT death by electrocution. factory service center or a DeWALT authorized service center in accordance with national and local electrical codes. • Electrical Grounding: Failure to provide • Make certain that the electrical circuit to adequate grounding to this product which the compressor is connected provides could result in serious injury or death proper electrical grounding, correct voltage from electrocution. See Grounding and adequate fuse protection. Instructions under Installation. INSTRUCTION MANUAL GUIDE D'UTILISATION MANUAL DE INSTRUCCIONES 1-800-4-DeWALT • www.dewalt.com If you have questions or comments, contact us. Pour toute question ou tout commentaire, nous contacter. Si tiene dudas o comentarios, contáctenos. (Mar17) NOTE: Air tanks, compressors and similar equipment used to inflate tires can fill small tires very rapidly. Adjust pressure regulator on air supply to no more than the rating of the tire pressure. Add air in small increments and frequently use the tire gauge to prevent over inflation. DeWALT Industrial Tool Co., 701 East Joppa Road, Baltimore, MD 21286 Part No. N503385 D55168 Copyright © 2007, 2008, 2009 2010, 2016, 2017 DeWALT The following are trademarks for one or more DeWALT power tools: the yellow and black color scheme; the “D” shaped air intake grill; the array of pyramids on the handgrip; the kit box configuration; and the array of lozengeshaped humps on the surface of the tool. Definitions: Safety Guidelines The definitions below describe the level of severity for each signal word. Please read the manual and pay attention to these symbols. DANGER: Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. NOTICE: Indicates a practice not related to personal injury which, if not avoided, may result in property damage. IF YOU HAVE ANY QUESTIONS OR COMMENTS ABOUT THIS OR ANY DeWALT TOOL, CALL US TOLL FREE AT: 1-800-4-DeWALT (1-800-433-9258) Important Safety Instructions WARNING: Do not operate this unit until you read this instruction manual for safety, operation and maintenance instructions. WARNING: This product contains chemicals known to the State of California to cause cancer, and birth defects or other reproductive harm. Wash hands after handling. WARNING: Some dust contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm such as asbestos and lead in lead based paint. SAVE THESE INSTRUCTION DANGER: RISK OF EXPLOSION OR FIRE WHAT CAN HAPPEN HOW TO PREVENT IT • It is normal for electrical contacts • Always operate the compressor in a well within the motor and pressure switch ventilated area free of combustible materials, to spark. gasoline, or solvent vapors. • If electrical sparks from compressor • If spraying flammable materials, locate come into contact with flammable compressor at least 20' (6.1 m) away from vapors, they may ignite, causing fire spray area. An additional length of hose may or explosion. be required. • Store flammable materials in a secure location away from compressor. • Restricting any of the compressor • Never place objects against or on top of ventilation openings will cause serious compressor pump. overheating and could cause fire. • Operate compressor in an open area at least 12" (30.5 cm) away from any wall or obstruction that would restrict the flow of fresh air to the ventilation openings. • Operate compressor in a clean, dry well ventilated area. Do not operate unit indoors or in any confined area. • Unattended operation of this product • Always remain in attendance with the could result in personal injury or product when it is operating. property damage. To reduce the risk • Always turn off and unplug unit when not of fire, do not allow the compressor to in use. operate unattended. DANGER: RISK TO BREATHING (ASPHYXIATION) WHAT CAN HAPPEN HOW TO PREVENT IT • The compressed air directly from your • Never use air obtained directly from the compressor is not safe for breathing. compressor to supply air for human The air stream may contain carbon consumption. The compressor is not monoxide, toxic vapors, or solid equipped with suitable filters and in-line safety particles from the air tank. Breathing equipment for human consumption. these contaminants can cause serious injury or death. • Exposure to chemicals in dust created • Work in an area with good cross ventilation. by power sanding, sawing, grinding, Read and follow the safety instructions drilling, and other construction activities provided on the label or safety data sheets may be harmful. for the materials you are spraying. Always use certified safety equipment: NIOSH/ • Sprayed materials such as paint, paint OSHA respiratory protection or properly fit­ solvents, paint remover, insecticides, ting face mask designed for use with your weed killers, may contain harmful specific application. vapors and poisons. WARNING: RISK OF BURSTING Air Tank: On February 26, 2002, the U.S. Consumer Product Safety Commission published Release # 02-108 concerning air compressor tank safety: Air compressor receiver tanks do not have an infinite life. Tank life is dependent upon several factors, some of which include operating conditions, ambient conditions, proper installations, field modifications, and the level of maintenance. The exact effect of these factors on air receiver life is difficult to predict. If proper maintenance procedures are not followed, internal corrosion to the inner wall of the air receiver tank can cause the air tank to unexpectedly rupture allowing pressurized air to suddenly and forcefully escape, posing risk of injury to consumers. Your compressor air tank must be removed from service by the end of the year shown on your tank warning label. The following conditions could lead to a weakening of the air tank, and result in a violent air tank explosion: WHAT CAN HAPPEN HOW TO PREVENT IT • Failure to properly drain condensed • Drain air tank daily or after each use. If air tank water from air tank, causing rust and develops a leak, replace it immediately with a thinning of the steel air tank. new air tank or replace the entire compressor. • Modifications or attempted repairs to the • Never drill into, weld, or make any modifications air tank. to the air tank or its attachments. Never attempt to repair a damaged or leaking air tank. Replace with a new air tank. • Unauthorized modifications to the safety • The air tank is designed to withstand specific valve or any other components which operating pressures. Never make adjustments control air tank pressure. or parts substitutions to alter the factory set operating pressures. Attachments & accessories: • Exceeding the pressure rating of air tools, • Follow the equipment manufacturers spray guns, air operated accessories, recommendation and never exceed the tires, and other inflatables can cause maximum allowable pressure rating of them to explode or fly apart, and could attachments. Never use compressor to result in serious injury. inflate small low pressure objects such as children’s toys, footballs, basketballs, etc. Tires: • Over inflation of tires could result in • Use a tire pressure gauge to check the tires serious injury and property damage. pressure before each use and while inflating tires; see the tire sidewall for the correct tire pressure. Final page size 10.875" x 25" WARNING: RISK FROM FLYING OBJECTS WHAT CAN HAPPEN HOW TO PREVENT IT • The compressed air stream can cause • Always wear certified safety equipment: ANSI soft tissue damage to exposed skin and Z87.1 eye protection (CAN/CSA Z94.3) with can propel dirt, chips, loose particles, side shields when using the compressor. and small objects at high speed, resulting • Never point any nozzle or sprayer toward any in property damage or personal injury. part of the body or at other people or animals. • Always turn the compressor off and bleed pressure from the air hose and air tank before attempting maintenance, attaching tools or accessories. WARNING: RISK OF HOT SURFACES WHAT CAN HAPPEN HOW TO PREVENT IT • Touching exposed metal such as the • Never touch any exposed metal parts on compressor head, engine head, engine compressor during or immediately after exhaust or outlet tubes, can result in operation. Compressor will remain hot for serious burns. several minutes after operation. • Do not reach around protective shrouds or attempt maintenance until unit has been allowed to cool. WARNING: RISK FROM MOVING PARTS WHAT CAN HAPPEN HOW TO PREVENT IT • Moving parts such as the pulley, • Never operate the compressor with guards or flywheel, and belt can cause serious covers which are damaged or removed. injury if they come into contact with you • Keep your hair, clothing, and gloves away or your clothing. from moving parts. Loose clothes, jewelry, or long hair can be caught in moving parts. • Air vents may cover moving parts and should be avoided as well. • Attempting to operate compressor • Any repairs required on this product should with damaged or missing parts or be performed by a DeWALT factory service attempting to repair compressor with center or a DeWALT authorized service center. protective shrouds removed can expose you to moving parts and can result in serious injury. WARNING: RISK OF UNSAFE OPERATION WHAT CAN HAPPEN HOW TO PREVENT IT • Unsafe op­er­a­tion of your air compressor • Review and understand all instructions and could lead to se­ri­ous in­ju­ry or death to warnings in this manual. you or others. • Be­come fa­mil­iar with the op­eration and con­ trols of the air compressor. • Keep operating area clear of all persons, pets, and obstacles. • Keep chil­dren away from the air compressor at all times. • Do not operate the product when fatigued or under the influence of alcohol or drugs. Stay alert at all times. • Never defeat the safety fea­tures of this prod­ uct. • Equip area of operation with a fire extinguisher. • Do not op­ er­ ate machine with missing, broken, or un­au­tho­rized parts. WARNING: RISK OF FALLING WHAT CAN HAPPEN HOW TO PREVENT IT • A portable compressor can fall from • Always operate compressor in a stable secure a table, workbench, or roof causing position to prevent accidental movement of damage to the compressor and could the unit. Never operate compressor on a roof result in serious injury or death to or other elevated position. Use additional air the operator. hose to reach high locations. WARNING: RISK OF INJURY FROM LIFTING WHAT CAN HAPPEN HOW TO PREVENT IT • Serious injury can result from attempting • The compressor is too heavy to be lifted by to lift too heavy an object. one person. Obtain assistance from others before lifting. WARNING: RISK FROM NOISE WHAT CAN HAPPEN HOW TO PREVENT IT • Under some conditions and duration • Always wear proper hearing protection of use, noise from this product may during use. contribute to hearing loss. SAVE THESE INSTRUCTIONS FOR FUTURE USE Components (Fig. 1) A. Mini-Switch B. Air Tank Pressure Gauge C. Regulated Pressure Gauge D. Pressure Regulator E. Quick Connect F. G. H. I. Check Valve Safety Valve Air Tank Drain Valve Air Intake Filter FEATURES (FIG. 1) MINI-SWITCH Place this switch (A) in the ON(I) position to start the unit and OFF(0) to remove power at the end of each use. PRESSURE SWITCH The pressure switch automatically starts the motor when the air tank pressure drops below the factory set cut-in pressure. It stops the motor when the air tank pressure reaches the factory set cut‑out pressure. SAFETY VALVE If the pressure switch does not shut off the air compressor at its cut-out pressure setting, the safety valve (G) will protect against high pressure by popping out at its factory set pressure (slightly higher than the pressure switch cut-out setting). CHECK VALVE When the air compressor is operating, the check valve (F) is open, allowing compressed air to enter the air tank. When the air compressor reaches cut-out pressure, the check valve closes, allowing air pressure to remain inside the air tank. TANK PRESSURE GAUGE The tank pressure gauge (B) indicates the reserve air pressure in the tank. REGULATED PRESSURE GAUGE The outlet pressure gauge (C) indicates the air pressure available at the outlet side of the regulator. This pressure is controlled by the regulator. REGULATOR The regulator (D) controls the air pressure shown on the regulated pressure gauge. Pull the knob out and turn clockwise to increase pressure and counterclockwise to decrease pressure. When the desired pressure is reached push knob in to lock in place. The regulated pressure range is 7–150 psi. WARNING: Risk of Bursting. Too much air pressure causes a hazardous risk of bursting. Check the manufacturer’s maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating. UNIVERSAL QUICK CONNECT BODY The universal quick connect body (E) accepts the three most popular styles of quick connect plugs: Industrial, automotive, and ARO. One hand push-to-connect operation makes connections simple and easy. DRAIN VALVE The drain valve (H) is located at the base of the air tank and is used to drain condensation at the end of each use. See Draining Air Tank under Maintenance. COOLING SYSTEM This compressor contains an advanced design cooling system. It is normal for this fan to blow air through the vent holes in large amounts. The cooling system is working when air is expelled. AIR COMPRESSOR PUMP The pump compresses air into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet. AIR INTAKE FILTER The filter (I) is designed to clean air entering the pump. To ensure the pump continually receives a clean, cool, and dry air supply the filter must always be clean and the filter intake must be free from obstructions. MOTOR OVERLOAD PROTECTOR The motor has a thermal overload protector. If the motor overheats for any reason, the overload protector will shut off the motor. The motor must be allowed to cool down before restarting. To restart: 1. Set the Mini-Switch to OFF(0) and unplug unit. 2. Allow the motor to cool. 3. Plug the power cord into the correct branch circuit receptacle. 4. Set the Mini-Switch to ON(I) position. FIG. 1 D B E C A I F INSTALLATION Assembly INSTALLING HOSES WARNING: Risk of unsafe operation. Firmly grasp hose in hand when installing or disconnecting to prevent hose whip. 1. Ensure regulated pressure gauge reads 0 psi. 2. Grasp the hose at the quick connect plug and push the plug into the quick connect body (E). Coupler will snap into place. 3. Grasp the hose and pull to ensure coupler is seated. DRAIN TANK DAI LY G DISCONNECTING HOSES WARNING: Risk of unsafe operation. Firmly grasp hose in hand when installing or disconnecting to prevent hose whip. 1. Ensure regulated pressure gauge reads 0 psi. 2. Pull coupler on quick connect body back to release quick connect plug on hose. FITTING THE WHEELS (FIG. 4) 1. Insert the bolt through the wheel and bracket as shown in Fig. 4. 2. Holding the locking nut in place with a wrench, tighten the wheel bolt securely. 3. Repeat these steps for the opposite wheel. H H FIG. 2 FIG. 3 M FITTING THE BUMPERS (FIG. 5) 1. Insert threaded bolt through the isolator and thread into the bracket hole as shown in Fig. 5. Tighten the bolt securely. 2. Repeat these steps for the opposite bumper. WARNING: Risk of Electrical Shock. In the event of a short circuit, grounding reduces the risk of shock by providing an escape wire for the electric current. This air compressor must be properly grounded. The portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug. 1. The cord set and plug (M) with this unit contains a grounding pin (L). This plug MUST be used with a grounded outlet (K). IMPORTANT: The outlet being used must be installed and grounded in accordance with all local codes and ordinances. 2. Ensure the outlet being used has the same configuration as the grounded plug. DO NOT USE AN ADAPTER. 3. Inspect the plug and cord before each use. Do not use if there are signs of damage. 4. If these grounding instructions are not completely understood, or if in doubt as to whether the compressor is properly grounded, have the installation checked by a qualified electrician. DANGER: Risk of Electrical Shock. IMPROPER GROUNDING CAN RESULT IN ELECTRICAL SHOCK. • Do not modify the plug provided. If it does not fit the available outlet, a correct outlet should be installed by a qualified electrician. • Repairs to the cord set or plug MUST be made by a qualified electrician. FIG. 4 Refer to the Voltage and Minimum Branch Circuit Requirements under Specifications. CAUTION: Risk of Overheating. Certain air compressors can be operated on a 15 amp circuit if the following conditions are met. • Voltage supply to circuit must comply with the National Electrical Code. • Circuit is not used to supply any other electrical needs. • Extension cords comply with specifications. • Circuit is equipped with a 15 amp circuit breaker or 15 amp time delay fuse. NOTE: If compressor is connected to a circuit protected by fuses, use only time delay fuses. Time delay fuses should be marked “D” in Canada and “T” in the US. If any of the above conditions cannot be met, or if operation of the compressor repeatedly causes interruption of the power, it may be necessary to operate it from a 20 amp circuit. It is not necessary to change the cord set. Compatibility NOTE: Always use an air line filter to remove moisture and oil vapor when spraying paint. Location Place the air compressor in a clean, dry and well ventilated area at least 12" (30.5 cm) away from the wall or other obstructions that will interfere with the flow of air. Keep the compressor away from areas that have dirt and/or volatile fumes in the atmosphere. These impurities may clog the intake filter and valves, causing inefficient operation. WARNING: The air compressor pump and shroud are designed to allow for proper cooling. The ventilation openings on the compressor are necessary to maintain proper operating temperature. Do not place rags or other containers on or near these openings. Place the air compressor on a flat surface resting on the rubber feet and wheels. ELECTRICAL Refer to all safety instructions before using unit. Observe extension cord safety instructions if necessary. Always place the switch to the OFF(0) position before removing the plug from the outlet. TRANSPORTING (FIG. 3) When transporting the compressor in a vehicle, trailer, etc., make sure the tank is drained and the unit is secured with straps to prevent tipping. Use care when driving to prevent tipping the unit over in the vehicle. Damage can occur to the compressor or surrounding items if the compressor is tipped. LIFTING Always use two people when lifting and lift from the recommended lift points (N). DO NOT lift by wheels or shroud. MOVING CAUTION: The wheels and handle do not provide adequate clearance, stability, or support for pulling the unit up and down stairs or steps. The unit must be lifted or pushed up a ramp. 1. Grasp handle of compressor and tilt compressor back to rest on wheels. WARNING: Risk of Unsafe Operation. Ensure proper footing and use caution when rolling compressor so that unit does not tip or cause loss of balance. 2. When location is reached slowly lower compressor to ground. Always store compressor in a vertical position resting on the rubber bumpers and wheels. PREPARATION FOR USE WARNING: Do not operate this unit until you read this instruction manual for safety, operation and maintenance instructions. Pre-Start Checklist (Fig. 1) 1. Ensure the Mini-Switch (A) is in the OFF(0) position. 2. Plug the power cord into the correct branch circuit receptacle. See Voltage and Circuit Protection under Installation. 3. Ensure air tank is drained, see Draining Air Tank under Maintenance. 4. Ensure the drain valve (H) is closed. 5. Ensure safety valve (G) is functioning properly, see Checking Safety Valve under Maintenance. 6. Pull the regulator knob (D) out and turn counterclockwise until fully closed. Ensure regulated pressure gauge reads 0 psi. Push knob in to lock in place. 7. Attach hose and accessories. NOTE: Always use a minimum 3/8" (9.5 mm) or greater air hose rated at 300 psi. WARNING: Risk of unsafe operation. Firmly grasp air hose in hand when installing or disconnecting to prevent hose whip. WARNING: Risk of unsafe operation. Do not use damaged or worn accessories. WARNING: Risk of Bursting. Too much air pressure causes a hazardous risk of bursting. Check the manufacturer’s maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating. OPERATING PROCEDURES Start-up (Fig. 1) 1. Follow Pre-Start Checklist under Preparation for Use. 2. Move the Mini-switch to the ON(I) position and allow tank pressure to build. Motor will stop when tank pressure reaches cut‑out pressure. NOTICE: Risk of Property Damage. Compressed air from the unit may contain wa­ter condensation and oil mist. Do not spray un­fil­tered air at an item that could be damaged by moisture. Some air op­er­ated tools or de­vic­es may require filtered air. Read the in­struc­tions for the air tool or device. 3. Adjust regulator (D) to desired setting. See Regulator under Features. Shut-down (Fig. 1) 1. Move Mini-Switch (A) to the OFF(0) position. NOTE: If finished using compressor, follow Steps 2–6. NOTE: When the unit has been turned off, it is normal to hear a short hiss of air being released. NOTE: Unplug unit when not in use. 2. Pull the regulator knob (D) out and turn counterclockwise until fully closed. Ensure regulated pressure gauge reads 0 psi. Push knob in to lock in place. 3. Remove hose and accessory. WARNING: Risk of unsafe operation. Firmly grasp air hose in hand when installing or disconnecting to prevent hose whip. 4. Drain the air tank, see Draining Air Tank under Maintenance. Ensure air tank pressure gauge reads 0 psi. WARNING: Risk of bursting. Drain air tank daily. Water will condense in air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture. 5. Allow the compressor to cool down. 6. Wipe air compressor clean and store in a safe, non-freezing area. MAINTENANCE The following procedures must be followed when maintenance or service is performed on the air compressor. 1. Ensure Mini-Switch is in the OFF(0) position. 2. Remove air compressor plug from outlet. FIG. 5 WARNING Extension Cords Voltage and Circuit Protection N L Grounding Instructions (Fig. 2) If an extension cord must be used, be sure it is: • a 3-wire extension cord that has a 3-blade grounding plug, and a 3‑slot receptacle that will accept the plug on the product • in good condition • no longer than 50 feet (15.2 m) • 12 gauge (AWG) or larger. (Wire size increases as gauge number decreases. 10 AWG and 8 AWG may also be used. DO NOT USE 14 OR 16 AWG.) NOTICE: Risk of Property Damage. The use of an undersized extension cord will cause voltage to drop resulting in power loss to the motor and overheating. Instead of using an extension cord, increase the working reach of the air hose by attaching another length of hose to its end. Attach additional lengths of hose as needed. N K DO N OT ADJUST FACTORY SETTINGS. TO REDUCE RISK OF ELE CTRIC SHOCK DO N OT REMOVE COVER. Pressure controls set at factory for maximum sa fe ope ration. ADVERTENCIA WARNING HOT SURFACES ADVERTENCIA SUPERFICIES CALIENTES AVERTISSEMENT SURFACES CHAUDES NO HAGA CAMBIOS ENLOS AJUSTES DE FÁBRICA. NO RETIRE LA TAPA PARA REDUCIR EL RIESGO DE CHOQUE ELÉ CTRICO. Los controles de presión se ajustan en la fábrica para máxima segu ridad en la ope ración. AVERTISSEMENT 3. Drain air tank. 4. Allow air compressor to cool down before starting service. NOTE: All compressed air systems contain maintenance parts (e.g., oil, filters, separators) that are periodically replaced. These used parts may contain substances that are regulated and must be disposed of in accordance with local, state, and federal laws and regulations. NOTE: Take note of the positions and locations of parts during disassembly to make reassembly easier. NOTE: Any service operations not included in this section should be performed by a DeWALT factory service center or a DeWALT authorized service center. Maintenance Chart Procedure Check safety valve Inspect air filter Daily Weekly See tank warning label X X Drain air tank X Check for unusual noise/vibration X Check for air leaks X1 Clean compressor exterior X Remove tank from service X2 1 - To check for air leaks apply a solution of soapy water around joints. While compressor is pumping to pressure and after pressure cuts out, look for air bubbles to form. 2 - For more information, call 1-800-4-DeWALT (1-800-433-9258) Checking Safety Valve WARNING: Risk of bursting. If the safety valve does not work properly, over-pressurization may occur, causing air tank rupture or an explosion. WARNING: Risk from flying objects. Always wear certified safety equipment: ANSI Z87.1 eye protection (CAN/CSA Z94.3) with side shields when using the compressor. Before starting compressor, pull the ring on the safety valve to make sure that the safety valve operates freely. NOTE: Ring may be difficult to pull when air tank pressure is at 0 psi. If the valve is stuck or does not operate smoothly, it must be replaced with the same type of valve. Draining Air Tank (Fig. 1) WARNING: Risk of unsafe operation. Risk from noise. Air tanks contain high pressure air. Keep face and other body parts away from outlet of drain. Use eye protection [ANSI Z87.1 (CAN/CSA Z94.3)] when draining as debris can be kicked up into face. WARNING: Risk from noise. Always wear proper hearing protection during use. Under some conditions and duration of use, noise from this product may contribute to hearing loss. NOTE: All compressed air systems generate condensate that accumulates in any drain point (e.g. tanks, filter, aftercoolers, dryers). This condensate contains lubricating oil and/or substances which may be regulated and must be disposed of in accordance with local, state, and federal laws and regulations. WARNING: Risk of bursting. Drain air tank daily. Water will condense in air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture. NOTICE: Risk of Property Damage. Drain water from air tank may contain oil and rust, which can cause stains. 1. Ensure Mini-Switch is in the OFF(0) position. 2. Place a suitable container under the drain valve (H) to catch discharge. 3. Grasp lever on drain valve. 4. Slowly rotate lever to gradually bleed air from air tank. 5. When air tank pressure gauge reads 10 psi, rotate valve to the fully open position. 6. Close drain valve when finished. Checking Air Filter Element (Fig. 1) WARNING: Hot surfaces. Risk of burn. Outlet tube, pump head, and surrounding parts are very hot, do not touch. Allow compressor to cool prior to servicing. 1. Ensure Mini-Switch is in the OFF(0) position. 2. Allow unit to cool. 3. Remove filter cover (J) from base. 4. Remove element from filter base. 5. Place new element back in filter base. Purchase replacement parts from your local dealer or authorized service center. Always use identical replacement parts. 6. Snap filter cover to filter base. NOTICE: Risk of unsafe operation. Do not operate without air inlet filter Accessories WARNING: The use of any other accessory not recommended for use with this tool could be hazardous. Use only accessories rated equal to or higher than the rating of the air compressor. Recommended accessories for use with your tool are available for purchase from your local dealer or authorized service center. If you need assistance in locating any accessory for your tool, please contact DeWALT Industrial Tool Co., 701 East Joppa Road, Towson, MD 21286, call 1-800-4-DeWALT (1-800-433-9258) or visit our website www.dewalt.com. Service Information Please have the following information available for all service calls: Model Number _____________________ Serial Number ________________________________ Date and Place of Purchase _______________________________________________________ Repairs To assure product SAFETY and RELIABILITY, repairs, maintenance and adjustment should be performed by a DeWALT factory service center, a DeWALT authorized service center or other qualified service personnel. Always use identical replacement parts. Full One Year Warranty DeWALT heavy duty industrial tools are warranted for one year from date of purchase. We will repair, without charge, any defects due to faulty materials or workmanship. For warranty repair information, call 1-800-4-DeWALT (1-800-433-9258). This warranty does not apply to accessories or damage caused where repairs have been made or attempted by others. This warranty gives you specific legal rights and you may have other rights which vary in certain states or provinces. LATIN AMERICA: This warranty does not apply to products sold in Latin America. For products sold in Latin America, see country specific warranty information contained either in the packaging, call the local company or see website for warranty information. FREE WARNING LABEL REPLACEMENT (Fig. 6): If your warning labels become illegible or are missing, call 1-800-4-DeWALT (1-800-433-9258) for a free replacement. GLOSSARY CFM: Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measure of air delivery. PSI: Pounds per square inch; a unit of measure of pressure. kPa (kilopascal): Metric pressure measurement. 1 kilopascal equal 1000 pascals. Code Certification: Products that bear one or more of the following marks: UL®, CUL, CULUS, ETL®, CETL, CETLUS, have been evaluated by OSHA certified independent safety laboratories and meet the applicable Standards for Safety. *UL® is a registered trademark of Underwriters Laboratories and ETL® is a registered trademark of Electrical Testing Laboratories. Cut-In Pressure: While the motor is off, air tank pressure drops when accessory is used. When the tank pressure drops to a certain low level the motor will restart automatically. The low pressure at which the motor automatically restarts is called cut-in pressure. Cut-Out Pressure: When an air compressor is turned on and begins to run, air pressure in the air tank begins to build. It builds to a certain high pressure before the motor automatically shuts off, protecting your air tank from pressure higher than its capacity. The high pressure at which the motor shuts off is called cut-out pressure. Branch Circuit: The circuit carrying electricity from electrical panel to outlet. Duty Cycle: This air compressor pump is capable of running continuously. However, to prolong the life of your air compressor, it is recommended that a 50%-75% average duty cycle be maintained; that is, the air compressor pump should not run more than 30-45 minutes in any given hour. Troubleshooting Guide This section provides a list of the more frequently encountered malfunctions, their causes and corrective actions. The operator or maintenance personnel can perform some corrective actions, and others may require the assistance of a qualified DeWALT technician or your dealer. Problem Code Excessive air tank pressure-safety valve pops off ................................................. 1, 2 Air leaks .................................................................................................................... 3 Air leaks in air tank or at air tank welds.................................................................... 4 Air leaks between head and valve plate.................................................................... 5 Air leaks from safety valve......................................................................................... 6 Knocking Noise......................................................................................................... 6 Pressure reading on the regulated pressure gauge drops when an accessory is used............................................................................. 7 Compressor is not supplying enough air to operate accessories.............................. ....................................................................................................... 8, 9, 10, 11, 12, 22 Regulator knob has continuous air leak.................................................................. 13 Regulator will not shut off air outlet........................................................................ 13 Motor will not run............................................................6, 14, 15, 16, 17, 18, 19, 20 Squealing Sound..................................................................................................... 21 Troubleshooting Codes CODE POSSIBLE CAUSE 1 4 Pressure switch does not shut off motor when compressor reaches cut-out pressure Pressure switch cut-out too high Tube fittings are not tight enough Defective air tank 5 Leaking seals 6 Defective safety valve 7 Regulator is not adjusted correctly for accessory being used 8 10 11 Prolonged excessive use of air Compressor is not large enough for accessory Hole in air hose Check valve restricted 12 13 Air leaks Regulator is damaged 14 Motor overload protection switch has tripped Tank pressure exceeds pressure switch cut-in pressure Extension cord is wrong length or gauge Loose electrical connections Possible defective motor Paint spray on internal motor parts 2 3 9 15 16 17 18 19 20 Fuse blown, circuit breaker tripped 21 Worn Belt 22 Restricted air intake filter POSSIBLE SOLUTION Set the Mini-Switch to OFF(0), if the unit does not shut off contact a DeWALT factory service center or a DeWALT authorized service center. Contact a DeWALT factory service center or a DeWALT authorized service center. Tighten fittings where air can be heard escaping. Check fittings with soapy water solution. Do Not Overtighten. Air tank must be replaced. Do not repair the leak. WARNING: Risk of bursting. Do not drill into, weld or otherwise modify air tank or it will weaken. The air tank can rupture or explode. Contact a DeWALT factory service center or a DeWALT authorized service center. Operate safety valve manually by pulling on ring. If valve still leaks, it must be replaced. It is normal for some pressure drop to occur when an accessory is used, adjust the regulator as instructed in Regulator under Features if pressure drop is excessive. NOTE: Adjust the regulated pressure under flow conditions while accessory is being used. Decrease amount of air usage. Check the accessory air requirement. If it is higher than the CFM or pressure supplied by your air compressor, a larger compressor is needed to operate accessory. Replace air hose. Contact a DeWALT factory service center or a DeWALT authorized service center. Tighten fittings. Replace. Refer to Motor Overload Protection under Features. If motor overload protection trips frequently, contact a DeWALT factory service center or a DeWALT authorized service center. Motor will start automatically when tank pressure drops below cutin pressure of pressure switch. Check for proper gauge wire and cord length. Refer to the Extension Cords paragraph in the Installation section. Contact a DeWALT factory service center or a DeWALT authorized service center. Contact a DeWALT factory service center or a DeWALT authorized service center. Contact a DeWALT factory service center or a DeWALT authorized service center. Do not operate the compressor in the paint spray area. See flammable vapor warning. 1. Check fuse box for blown fuse and replace as necessary. Reset circuit breaker. Do not use a fuse or circuit breaker with higher rating than that specified for our particular branch circuit. 2. Check for proper fuse. You should use a time delay fuse. 3. Check for low voltage conditions and/or proper extension cord. 4. Disconnect the other electrical appliances from circuit or operate the compressor on its own branch circuit. Contact a DeWALT factory service center or a DeWALT authorized service center. Clean or replace air intake filter. Do not operate the air compressor with the filter removed. Refer to the Air Filter paragraph in the Maintenance section. Définitions : lignes directrices en matière de sécurité Les définitions ci-dessous décrivent le niveau de gravité pour chaque symbole. Veuillez lire le mode d’emploi et porter une attention particulière à ces symboles. DANGER : Indique une situation dangereuse imminente qui, si elle n’est pas évitée, causera la mort ou des blessures graves. AVERTISSEMENT : Indique une situation potentiellement dangereuse qui, si elle n’est pas évitée, pourrait se solder par un décès ou des blessures graves. ATTENTION : Indique une situation potentiellement dangereuse qui, si elle n’est pas évitée pourrait se solder par des blessures mineures ou modérées. AVIS : Indique une pratique ne posant aucun risque de dommages corporels mais qui par contre, si rien n’est fait pour l’éviter, pourrait poser des risques de dommages matériels. POUR TOUTES QUESTIONS OU COMMENTAIRES RELATIFS(VES) À L’OUTIL OU À PROPOS DE TOUT AUTRE OUTIL DeWALT, COMPOSER SANS FRAIS LE : 1-800-4-DeWALT (1-800-433-9258) Directives de sécurité importantes AVERTISSEMENT : ne pas utiliser cet appareil avant d’avoir lu le mode d’emploi ainsi que l’intégralité des directives de sécurité, d’utilisation et d’entretien. AVERTISSEMENT : ce produit contient des produits chimiques reconnus par l’État de la Californie comme étant cancérigènes et pouvant entraîner des anomalies congénitales ou d’autres problèmes liés aux fonctions reproductrices. Se laver les mains après toute manipulation. AVERTISSEMENT : certaines poussières contiennent des produits chimiques reconnus par l’État de la Californie comme cancérigènes et pouvant entraîner des anomalies congénitales et d’autres problèmes liés aux fonctions reproductrices, tels que l’amiante et le plomb contenus dans les peintures au plomb. CONSERVER CES DIRECTIVES DANGER : RISQUE D’EXPLOSION OU D’INCENDIE CE QUI PEUT SE PRODUIRE COMMENT L’ÉVITER • Il est normal que des contacts • Faites toujours fonctionner le compresseur dans électriques dans le moteur et le une zone bien aérée sans matière combustible, manocontacteur fassent une étincelle. essence ou vapeur de solvant. • Si une étincelle électrique provenant • Si vous aspergez des matériaux inflammables, du compresseur entre en contact avec placez le compresseur à au moins 6,1 m (20 pieds) des vapeurs inflammables, elle peut de la zone pulvérisée. Il est possible que vous ayez s’enflammer et causer un incendie ou besoin d’une longueur de tuyau additionnelle. une explosion. • Entreposez les matières inflammables dans un endroit sécuritaire, éloigné du compresseur. • Le fait de limiter les ouvertures • Ne jamais placer d'objets contre la pompe du d’aération de compresseur causera compresseur ou sur celle-ci. une importante surchauffe et pourrait • Faites fonctionner le compresseur dans un endroit causer un incendie. aéré à au moins 30,5 cm (12 po) du mur ou de l’obstruction qui pourrait limiter le débit d’air frais dans les ouvertures d’aération. • Faites fonctionner le compresseur dans un endroit propre, sec et bien aéré. Ne pas utiliser l’appareil à l’intérieur ou dans un endroit exigu. • Le fonctionnement de ce produit • Être toujours présent lorsque le produit est sans surveillance pourrait se solder en marche. par des blessures personnelles ou • Toujours éteindre et débrancher l'appareil si des dommages à la propriété. Afin non utilisé. de réduire le risque d’incendie, ne pas laisser le compresseur fonctionner sans surveillance. DANGER : RISQUE REPIRATOIRE (ASPHYXIE) CE QUI PEUT SE PRODUIRE COMMENT L’ÉVITER • Il est dangereux de respirer l’air • Ne jamais utiliser l’air obtenu directement du comprimé sortant du compresseur. Le compresseur pour l’alimentation en air destinée à flux d’air peut contenir du monoxyde la consommation humaine. Le compresseur n’est de carbone, des vapeurs toxiques ou pas muni de filtres et d’équipement de sécurité en des particules solides provenant du ligne qui conviennent à la consommation humaine. réservoir d’air. La respiration de ces contaminants peut causer de sérieuses blessures, voire la mort. • Une exposition aux produits • Travailler dans un endroit ayant une bonne chimiques présents dans la aération transversale. Lire et respecter les poussière générée par les activités directives en matière de sécurité imprimées de ponçage, sciage, meulage, sur l’étiquette ou les fiches signalétiques des perçage et autres, peut être nocive. matériaux qui sont pulvérisés. Toujours utiliser un équipement de sécurité homologué : une • Les matériaux vaporisés comme la protection respiratoire conforme aux normes peinture, les solvants de peinture, NIOSH/OSHA, ou un masque facial bien les décapants, les insecticides, les ajusté, conçus spécifiquement pour votre herbicides, pourraient contenir des utilisation particulière. vapeurs nocives et du poison. AVERTISSEMENT : RISQUE D’ÉCLATEMENT Réservoir d’air comprimé : Le 26 février 2002, la U.S. Consumer Product Safety Commission américaine a publié la règle nº 02-108 portant sur la sécurité en matière de réservoir d’air comprimé des compresseurs : Les réservoirs d’air comprimé des compresseurs n’ont pas une durée de vie illimitée. La durée de vie des réservoirs dépend de plusieurs facteurs, qui comprennent entre autres : les conditions d’utilisation, les conditions ambiantes, une installation adéquate, les modifications sur site, et le niveau de maintenance. L’effet exact que peut avoir ces facteurs sur la durée de vie des réservoirs d’air est difficilement prévisible. Si les procédures adéquates de maintenance ne sont pas suivies, la corrosion sur la paroi interne du réservoir d’air comprimé peut faire que celui-ci éclate de façon inopinée laissant soudainement l’air pressurisé s’échapper avec force, posant ainsi des risques de dommages corporels à l’utilisateur. Le réservoir d’air de votre compresseur doit être mis hors service à la fin de l’année mentionnée sur l’étiquette d’avertissement apposée sur le réservoir. Les conditions suivantes peuvent amener la dégradation du réservoir d’air, et faire que ce dernier explose violemment : CE QUI PEUT SE PRODUIRE COMMENT L’ÉVITER • L’eau condensée n’est pas • Vidanger le réservoir d’air quotidiennement correctement vidangée du réservoir ou après chaque utilisation. Si le réservoir d’air provoquant ainsi la formation présente une fuite, le remplacer immédiatement de rouille et un amincissement du par un nouveau réservoir d’air ou par un réservoir d’air en acier. nouveau compresseur. • Modifications apportées au réservoir • Ne jamais percer un trou dans le réservoir d’air d’air ou tentatives de réparation. ou ses accessoires, y faire de la soudure ou y apporter quelque modification que ce soit. Ne jamais essayer de réparer un réservoir d’air endommagé ou avec des fuites. Le remplacer par un nouveau réservoir d’air. • Des modifications non autorisées de la • Le réservoir d’air a été conçu pour supporter soupape de sûreté ou de tous autres des pressions spécifiques de fonctionnement. composants qui régissent la pression Ne faites jamais effectuer de réglages ou de du réservoir d’air. substitutions de pièces en vue de modifier les pressions de fonctionnement réglées en usine. Accessoires : • Lorsqu’on excède la pression nominale • Respecter les recommandations du fabricant de des outils pneumatiques, des pistolets l’équipement et ne jamais dépasser la pression pulvérisateurs, des accessoires à nominale maximale permise des accessoires. commande pneumatique, des pneus Ne jamais utiliser le compresseur pour gonfler de et d’autres dispositifs pneumatiques, petits objets à basse pression comme des jouets on risque de les faire exploser ou d’enfant, des ballons de football et de basketde les projeter et ainsi entraîner des ball, etc. blessures graves. Pneus : • Des pneus surgonflés pourraient • Utiliser un manomètre pour vérifier la pression des provoquer des blessures graves et des pneus avant chaque utilisation et lors du gonflage; dommages à la propriété. consulter le flanc de pneu pour obtenir la pression correcte. REMARQUE : Les réservoirs d’air comprimé, compresseurs et autres équipements similaires utilisés pour gonfler les pneus peuvent remplir ces derniers très rapidement. Régler le régulateur de pression d’air à une pression moindre que celle indiquée sur le pneu. Ajouter de l’air par petite quantité et utiliser fréquemment le manomètre pour empêcher un surgonflage. AVERTISSEMENT : RISQUE DE CHOC ÉLECTRIQUE CE QUI PEUT SE PRODUIRE COMMENT L’ÉVITER • Votre compresseur d’air est alimenté • Ne faites jamais fonctionner le compresseur à l’électricité. Tout comme n’importe à l’extérieur lorsqu’il pleut ou dans des quel autre dispositif alimenté de conditions humides. façon électrique, s’il n’est pas utilisé • Ne faites jamais fonctionner le compresseur correctement, il peut causer un avec les couvercles de protection enlevés choc électrique. ou endommagés. • Les tentatives de réparation par un • Tout câblage électrique ou toute réparation personnel non qualifié peuvent résulter nécessaire pour ce produit doit être pris en en de graves blessures, voire la mort charge par un centre de réparation en usine par électrocution. autorisé DeWALT ou un centre de réparation DeWALT conformément aux codes électriques nationaux et locaux. • Mise à la terre électrique : Le • Assurez-vous que le circuit électrique auquel le fait de ne pas faire une mise à la compresseur est branché fournit une mise à la terre adéquate de ce produit pourrait terre électrique adéquate, une tension appropriée résulter en des blessures graves voire et une bonne protection des fusibles. la mort par électrocution. Consulter les directives relatives à la mise à la terre sous Installation. AVERTISSEMENT : RISQUE PROVENANT DES OBJETS PROJETÉS EN L’AIR CE QUI PEUT SE PRODUIRE COMMENT L’ÉVITER • Le flux d’air comprimé peut • Toujours utiliser de l’équipement de sécurité endommager les tissus mous de homologué : protection oculaire conforme la peau exposée et peut projeter à la norme ANSI Z87.1 (CAN/CSA Z94.3) la poussière, des fragments, des munie d’écrans latéraux lors de l’utilisation particules détachées et des petits du compresseur. objets à haute vitesse, ce qui • Ne jamais pointer une buse ou un pulvérisateur entraînerait des dommages et des vers une partie du corps ou vers d’autres blessures personnelles. personnes ou des animaux. • Toujours mettre le compresseur hors tension et purger la pression du tuyau à air et du réservoir d’air avant d’effectuer l’entretien, de fixer des outils ou des accessoires. AVERTISSEMENT : ATTENTION SURFACES CHAUDES CE QUI PEUT SE PRODUIRE COMMENT L’ÉVITER • Toucher à du métal exposé comme • Ne jamais toucher à des pièces métalliques la tête du compresseur ou du moteur, exposées sur le compresseur pendant ou la tubulure des gaz d’échappement immédiatement après son utilisation. Le ou de sortie, peut se solder en de compresseur reste chaud pendant plusieurs sérieuses brûlures. minutes après son utilisation. • Ne pas toucher ni effectuer des réparations aux coiffes de protection avant que l’appareil n’ait refroidi. AVERTISSEMENT : RISQUE ASSOCIÉ AUX PIÈCES MOBILES CE QUI PEUT SE PRODUIRE COMMENT L’ÉVITER • Les pièces mobiles comme une poulie, • Ne jamais utiliser le compresseur si les protecteurs un volant ou une courroie peuvent ou les couvercles sont endommagés ou retirés. provoquer de graves blessures si • Tenir les cheveux, les vêtements et les gants elles entrent en contact avec vous ou hors de portée des pièces en mouvement. Les vos vêtements. vêtements amples, bijoux ou cheveux longs peuvent s’enchevêtrer dans les pièces mobiles. • S’éloigner des évents car ces derniers pourraient camoufler des pièces mobiles. • Utiliser le compresseur avec des • Toutes les réparations requises pour ce produit pièces endommagées ou manquantes devraient être effectuées par un centre de ou le réparer sans coiffes de protection réparation de l’usine DeWALT ou un centre de risque de vous exposer à des pièces réparation autorisé DeWALT. mobiles et peut se solder par de graves blessures. AVERTISSEMENT : RISQUE ASSOCIÉ À UTILISATION DANGEREUSE CE QUI PEUT SE PRODUIRE COMMENT L’ÉVITER • Une utilisation dangereuse de votre • Revoir et comprendre toutes les directives et compresseur d’air pourrait provoquer les avertissements contenus dans le présent de graves blessures, voire votre décès mode d’emploi. ou celle d’autres personnes. • Se familiariser avec le fonctionnement et les commandes du compresseur d’air. • Dégager la zone de travail de toutes personnes, animaux et obstacles. • Tenir les enfants hors de portée du compresseur d’air en tout temps. • Ne pas utiliser le produit en cas de fatigue ou sous l’emprise d’alcool ou de drogues. Rester vigilant en tout temps. • Ne jamais rendre inopérant les fonctionnalités de sécurité du produit. • Installer un extincteur dans la zone de travail. • Ne pas utiliser l’appareil lorsqu’il manque des pièces ou que des pièces sont brisées ou non autorisées. AVERTISSEMENT : RISQUE DE CHUTE CE QUI PEUT SE PRODUIRE COMMENT L’ÉVITER • Un compresseur portatif peut tomber • Toujours faire fonctionner le compresseur alors d’une table, d’un établi ou d’un qu’il est dans uns position sécuritaire et stable toit et causer des dommages au afin d’empêcher un mouvement accidentel compresseur, ce qui pourrait résulter de l’appareil. Ne jamais faire fonctionner le en de graves blessures, voire la mort compresseur sur un toit ou sur toute autre position de l’opérateur. élevée. Utiliser un tuyau d’air supplémentaire pour atteindre les emplacements en hauteur. AVERTISSEMENT : RISQUE DE BLESSURE EN SOULEVANT LE PRODUIT CE QUI PEUT SE PRODUIRE COMMENT L’ÉVITER • Soulever un objet trop lourd peut se • Le compresseur est trop lourd pour être soulevé solder par de graves blessures. par une seule personne. Demander de l’aide avant de le soulever. AVERTISSEMENT : RISQUE ASSOCIÉ AU BRUIT CE QUI PEUT SE PRODUIRE COMMENT L’ÉVITER • Dans certaines conditions et selon la • Porter systématiquement une protection durée d’utilisation, le bruit provoqué auditive appropriée durant l’utilisation. par ce produit peut contribuer à une perte auditive. CONSERVER CES DIRECTIVES POUR UN USAGE ULTÉRIEUR Composants (Fig. 1) A. B. C. D. E. Mini-interrupteur Manomètre du réservoir d’air Manomètre régulé Régulateur de pression Branchements rapides F. G. H. I. Clapet Soupape de sûreté Soupape de purge du réservoir d’air Filtre d’admission d’air CARACTÉRISTIQUES (FIG.1) MINI-INTERRUPTEUR Mettez cet interrupteur (A) sur la position MARCHE (I) pour démarrer l’appareil et sur ARRÊT (0) pour couper l’alimentation en fin d’utilisation. MANOCONTACTEUR Le manocontacteur démarre automatiquement le moteur lorsque la pression du réservoir d’air chute sous la pression d’enclenchement réglée en usine. Il arrête le moteur lorsque la pression du réservoir d’air atteint la pression de déclenchement réglée en usine. SOUPAPE DE SÛRETÉ Si le manocontacteur ne met pas hors tension le compresseur d’air à sa pression de déclenchement réglée, la soupape de sûreté (G) sert de protection contre une pression élevée en allant à la pression réglée en usine (pression légèrement plus élevée que le réglage de déclenchement du manocontacteur). CLAPET Lorsque le compresseur d’air fonctionne, le clapet (F) est ouvert, ce qui permet à l’air comprimé d’entrer dans le réservoir d’air. Lorsque le compresseur d’air atteint la pression de déclenchement, le clapet se ferme, ce qui permet à la pression d’air de rester dans le réservoir d’air. MANOMÈTRE DE RÉSERVOIR Le manomètre de réservoir (B) indique la pression d’air de réserve dans le réservoir. MANOMÈTRE DE PRISE DE COURANT Le manomètre de prise (C) indique la pression d’air disponible du côté de la prise du régulateur. Cette pression est contrôlée par le régulateur. RÉGULATEUR Le régulateur (D) contrôle la pression d'air indiqué sur le manomètre de sortie. Tirez le bouton et tournez-le dans le sens des aiguilles d'une montre pour augmenter la pression et dans le sens contraire pour réduire la pression. Une fois que la pression désirée est atteinte, poussez le bouton pour le verrouiller. The regulated pressure range is 7–150 psi. AVERTISSEMENT : risque d’éclatement. Purger le réservoir d’air quotidiennement. L’eau se condensera dans le réservoir d’air. Si l’eau n’est pas vidangée, elle corrodera et affaiblira le réservoir d’air, provoquant ainsi un risque de rupture du réservoir d’air. CORP DE BRANCHEMENT RAPIDE UNIVERSEL Le corps de branchement rapide universel (E) accepte les trois styles de prises de branchement rapide les plus populaires : industrielle, automobile, et ARO. Il suffit tout simplement d’appuyer une seule fois pour connecter le corps de branchement rapide à la prise. ROBINET DE PURGE Le robinet de purge (H) se trouve à la base du réservoir d’air et est utilisé pour vidanger la condensation à la fin de chaque utilisation. Consulter le chapitre Vidange du réservoir sous Entretien. SYSTÈME DE REFROIDISSEMENT Ce compresseur contient un système de refroidissement de conception évoluée. Il est tout à fait normal pour ce ventilateur de souffler de l’air par les orifices d’aération en grandes quantités. Le système de refroidissement fonctionne lorsque l’air est expulsé. POMPE DE COMPRESSEUR D’AIR La pompe compresse l’air dans le réservoir d’air. L’air de travail n’est pas disponible avant que le compresseur ait augmenté la pression du réservoir d’air au-dessus de ce qui est requis à la sortie d’air. FILTRE D’ADMISSION D’AIR Le filtre (I) sert à purifier l’air qui ente dans la pompe. Pour que la pompe reçoive un flux d’air constant propre, froid et sec, le filtre doit toujours être propre et l’entrée d’air doit être exempte d’obstructions. PROTECTEUR DE SURCHARGE DU MOTEUR Le moteur dispose d’un protecteur de surcharge thermique. Si le moteur surchauffe, peu importe la raison, le protecteur de surcharge met le moteur hors tension. Il faut donner au moteur le temps de refroidir avant de le redémarrer. Redémarrage : 1. Réglez le mini-interrupteur (A) sur ARRÊT (0) et débranchez l’appareil. 2. Laisser le moteur refroidir. 3. Brancher le cordon d’alimentation dans le bon réceptacle de circuit de dérivation. 4. Réglez le mini-interrupteur sur la position MARCHE (I). INSTALLATION Assemblage RACCORDEMENT DES TUYAUX AVERTISSEMENT : risque d’utilisation dangereuse. Saisir fermement le tuyau en main lors du raccordement ou de la déconnexion pour empêcher un à-coup du tuyau. 1. S’assurer que le manomètre régulé indique 0 psi. 2. Saisir le tuyau au niveau de la prise de branchement rapide et enfoncer la prise dans le corps de branchement rapide (E). Le coupleur se mettra en place. 3. Saisir le tuyau et tirer pour s’assurer que le coupleur est bien en place. AVERTISSEMENT : la pompe de compresseur d’air et le déflecteur ont été conçus pour assurer un refroidissement adéquat. Les ouvertures d’aération sur le compresseur sont nécessaires pour garder une température de fonctionnement appropriée. Ne placez pas de chiffons ou d’autres contenants sur les ouvertures ou à proximité de celles-ci. Placer le compresseur d’air sur une surface plane et s’assurer qu’il repose sur ses pieds de caoutchouc et ses roulettes ÉLECTRICITÉ Consulter toutes les directives de sécurité avant d’utiliser l’appareil. Respecter les directives de sécurité du cordon d’alimentation le cas échéant. Positionnez systématiquement l’interrupteur (L) sur ARRÊT (0) avant de retirer la fiche de la prise. TRANSPORT (FIG. 3) Lors du transport du compresseur d’air dans un véhicule, une remorque, etc. s’assurer que le réservoir d’air soit bien purgé et que l’appareil soit bien ancré. Conduire prudemment pour éviter de basculer l’appareil dans le véhicule. Un basculement risque d’endommager le compresseur ou les pièces contiguës. LEVAGE Toujours soulever l'appareil à deux personnes et utiliser les points de transport (N) recommandés. NE PAS le lever par la roues ou le déflecteur. DÉPLACEMENT ATENCIÓN : les roues et la poignée n'offrent pas le dégagement, la stabilité ou l'appui nécessaire pour descendre ou monter des escaliers ou des marches avec l'appareil. On doit soulever l'appareil ou le pousser le long d'une rampe. 1. Pour ce faire, saisir la poignée du compresseur et l'incliner vers l'arrière sur ses roues. AVERTISSEMENT : garder les pieds bien ancrés et faire preuve d’une grande prudence en transportant le compresseur afin d’éviter de perdre l’équilibre. 2. Une fois le compresseur à l'endroit voulu, l'abaisser lentement sur le sol. Toujours ranger le compresseur en position verticale en l'appuyant sur les amortisseurs et les roues. MODE D’EMPLOI AVERTISSEMENT : ne pas utiliser cet appareil avant d’avoir lu le mode d’emploi ainsi que l’intégralité des directives de sécurité, d’utilisation et d’entretien. Liste de vérification de pré-démarrage (Fig. 1) 1. Assurez-vous que le mini-interrupteur (A) est sur la position ARRÊT (0). 2. Branchez le cordon d’alimentation dans le bon réceptacle de circuit de dérivation. Consulter la rubrique Protection de la tension et du circuit sous Installation. 3. S’assurer que le réservoir d’air soit bien purgé, consulter la rubrique Vidange du réservoir d’air sous Entretien. 4. S’assurer que la soupape de purge (H) soit fermée. 5. S’assurer que la soupape de sûreté (G) fonctionne correctement, consulter la rubrique Vérification de la soupape de sûreté sous Entretien. 6. Tirez le bouton du régulateur et tourner le bouton du régulateur (D) en sens antihoraire jusqu’à fermeture complète. S’assurer que le manomètre régulé indique 0 psi. Poussez le bouton pour le verrouiller. 7. Fixez le tuyau et les accessoires. NOTE: Toujours utiliser un tuyau d’air de 9,5 mm (3/8 po) ou plus prévu pour une pression de 300 psi. AVERTISSEMENT : risque d’utilisation dangereuse. Saisir fermement le tuyau en main lors du raccordement ou de la déconnexion pour empêcher un à-coup du tuyau. AVERTISSEMENT : risque d’utilisation dangereuse. N'utilisez pas les accessoires endommagés ou portés. AVERTISSEMENT : risque d’éclatement. Trop de pression d’air cause un risque sérieux d’éclatement. Vérifiez la pression maximum suggérée par le fabricant pour les outils pneumatiques et les accessoires. La pression de sortie du régulateur ne doit jamais dépasser une pression nominale maximale. PROCÉDURES DE FONCTIONNEMENT Démarrage (Fig. 1) 1. Utiliser la Liste de vérification de pré-démarrage sous Mode d’emploi. 2. Poussez le mini-interrupteur sur la position MARCHE (I) et laissez la pression monter dans le réservoir. Le moteur s’arrête lorsque la pression du réservoir atteint la pression de déclenchement. AVIS : risque de dégats matériels. L’air comprimé de l’appareil pourrait contenir de l’eau condensée et des brumes d’huile. Ne pas vaporiser de l’air non filtré sur un article que l’humidité pourrait endommager. Certains outils ou dispositifs pneumatiques pourraient requérir de l’air filtré. Lire les directives pour l’outil ou le dispositif pneumatique. 3. Régler le régulateur (D) à la valeur souhaitée. Consulter la rubrique Régulateur sous Caractéristiques. Arrêt (Fig. 1) 1. Poussez le mini-interrupteur (A) sur la position ARRÊT (0). REMARQUE : Si l’utilisation du compresseur est terminée, suivre les étapes 2 à 6. REMARQUE : Lorsque l’appareil est éteint, il est normal d’entendre un court sifflement quand l’air s’échappe. REMARQUE : Débranchez l’appareil après utilisation. 2. Tirez le bouton du régulateur et tourner le bouton du régulateur (D) en sens antihoraire jusqu’à fermeture complète. S’assurer que le manomètre régulé indique 0 psi. Poussez le bouton pour le verrouiller. 3. Retirer le tuyau et l’accessoire. AVERTISSEMENT : risque d’utilisation dangereuse. Saisir fermement le tuyau en main lors du raccordement ou de la déconnexion pour empêcher un à-coup du tuyau. 4. Purger le réservoir d’air, consulter la rubrique Purger le réservoir d’air sous Entretien. S’assurer que le manomètre du réservoir d’air affiche 0 psi. AVERTISSEMENT : risque d’éclatement. Purger le réservoir d’air quotidiennement. L’eau se condensera dans le réservoir d’air. Si l’eau n’est pas vidangée, elle corrodera et affaiblira le réservoir d’air, provoquant ainsi un risque de rupture du réservoir d’air. 5. Laisser refroidir le compresseur. 6. Nettoyer le compresseur d’air avec un chiffon et le ranger dans un endroit sûr sans risque de gel. ENTRETIEN INSTALLATION DES ROUES (Fig. 4) 1. Insérez le boulon dans la roue et le dispositif de fixation, comme illustré en figure 4. 2. Tout en maintenant fermement l’écrou de blocage avec une clé, resserrez soigneusement le boulon de la roue. 3. Répétez le même processus pour l’autre roue. Suivre les procédures suivantes lors de l’entretien ou des réparations du compresseur d’air. 1. Assurez-vous que le mini-interrupteur (A) est sur la position ARRÊT (0). 2. Débrancher le compresseur d’air. 3. Purger le réservoir d’air. 4. Laisser refroidir le compresseur d’air avant de débuter une réparation. REMARQUE : Tous les systèmes de compression d’air comprennent des pièces (par ex., huile, filtres, séparateurs) qui sont régulièrement remplacées. Ces pièces usées pourraient contenir des substances contrôlées et doivent être mises au rebut conformément aux lois et règlements municipaux, provinciaux, territoriaux et fédéraux. REMARQUE : Noter la position et l’emplacement des pièces au démontage pour faciliter le remontage subséquent. REMARQUE : Toute réparation non décrite dans cette rubrique devrait être exécutée à un centre de réparation de l’usine DeWALT ou un centre de réparation agréé DeWALT. INSTALLATION DES PARE-CHOCS (Fig. 5) 1. Insérez le boulon fileté dans l’isolateur et vissez-le dans l’orifice du dispositif de fixation, comme illustré en figure 5. Resserrez soigneusement le boulon. 2. Répétez le même processus pour l’autre pare-choc. Procédure DÉCONNEXION DES TUYAUX AVERTISSEMENT : risque d’utilisation dangereuse. Saisir fermement le tuyau en main lors du raccordement ou de la déconnexion pour empêcher un à-coup du tuyau. 1. S’assurer que le manomètre régulé indique 0 psi. 2. Retirer le coupleur du corps de branchement rapide pour dégager la prise de branchement rapide du tuyau. Directives relatives à la mise à la terre (Fig. 2) AVERTISSEMENT : risque de choc électrique. Au cas où un court-circuit se produirait, la mise à la terre réduit le risque de choc électrique en fournissant un fil d’échappement pour le courant électrique. Le compresseur d’air doit être correctement mis à la terre. Le compresseur d’air portatif est muni d’un cordon ayant un fil de mise à terre avec une prise de mise à la terre. 1. Le cordon qui se fixe et se branche (M) avec cet appareil contient une goupille de mise à la terre (L). Cette prise DOIT être utilisée avec une prise correctement mise à la terre (K). IMPORTANT : La prise utilisée doit être installée et mise à la terre en fonction de tous les codes et de toutes les ordonnances à l’échelle locale. 2. Assurez-vous que la prise utilisée a la même configuration que la fiche mise à la terre. N’UTILISEZ PAS UN ADAPTATEUR. 3. Inspectez la fiche et le cordon avant chaque utilisation. Ne les utilisez pas s’ils présentent des signes de dommages. 4. Si ces directives sur la mise à la terre ne sont pas entièrement comprises, ou si vous n’êtes pas certain que le compresseur a correctement été mis à la terre, faites vérifier l’installation par un électricien qualifié. DANGER : risque de choc électrique. UNE MISE À LA TERRE INADÉQUATE PEUT PROVOQUER UN CHOC ÉLECTRIQUE. • Ne modifiez pas la fiche fournie. Si elle ne s’incère pas dans la prise disponible, une prise adéquate doit être installée par un électricien qualifié. • Les réparations au cordon ou à la fiche DOIVENT être faites par un électricien qualifié. Rallonges Si une rallonge doit être utilisée, s'assurer : • d'utiliser une rallonge à trois fils, munie d'une fiche à trois lames avec mise à la terre et une prise de courant à trois fentes qui accepte la fiche de la rallonge; • qu'elle est en bon état; • qu'elle n'excède pas 50 pi (15,2 m); • que les fils sont d'un calibre minimum de 12 AWG. (La grosseur du fil augmente comme le numéro de calibre diminue. Les fils de calibre 10 AWG et 8 AWG peuvent également être utilisés. NE PAS UTILISER UN FIL DE CALIBRE 14 OU 16 AWG.) AVIS : risque de dégats matériels. L'utilisation d'une rallonge produira une chute de tension qui entraînera une perte de puissance au moteur ainsi qu'une surchauffe. Au lieu d'utiliser une rallonge électrique, augmentez plutôt la longueur du boyau d'air en connectant un autre boyau à l'extrémité. Connectez des boyaux supplémentaires au besoin. Protection de la tension et du circuit Consulter les Exigences en matière de tension et de circuit de dérivation minimales sous Fiche technique de la pompe/du moteur. ATTENTION : risques de surchauffe. Certains compresseurs d’air peuvent fonctionner sur un circuit de 15 A si les conditions suivantes sont réunies. • L’alimentation en tension doit se conformer au Code électrique national. • Le circuit n’est pas utilisé pour alimenter d’autres besoins en électricité. • Les rallonges doivent se conformer aux spécifications. • Le circuit est équipé d’un disjoncteur de 15 A au minimum ou d’un fusible à temporisation de 15 A. REMARQUE : si le compresseur est branché à un circuit protégé par des fusibles, utiliser seulement des circuits à temporisation. Les fusibles de temporisation devraient avoir l’inscription « D » au Canada et « T » aux É.-U. Si une des conditions ci-dessus n’est pas satisfaite, ou si le fonctionnement du compresseur cause des interruptions du courant électrique, il peut s’avérer nécessaire de faire fonctionner l’appareil à partir d’un circuit à 20 A. Il n’est pas nécessaire de changer les cordons. Compatibilité REMARQUE : Toujours utiliser un filtre de canalisation d’air pour retirer l’humidité et les vapeurs d’huile lors de la pulvérisation de peinture. Emplacement Placer le compresseur d’air dans un endroit propre, sec et bien aéré à au moins 30,5 cm (12 po) du mur ou d’autres obstructions qui pourraient interférer avec le débit d’air. Tenir le compresseur à l’écart des endroits poussiéreux et chargés d’émanations. Ces impuretés pourraient boucher le filtre et les soupapes d’admission et s’y agglutiner, nuisant ainsi au bon fonctionnement du compresseur d’air. Programme d’entretien Quotidienne Hebdomadaire Se reporter à l’étiquette d’avertissement sur le réservoir Vérification de la soupape de sûreté X Inspecter le filtre à air X Vidange du réservoir d’air X Recherche de bruits ou de vibrations inhabituels X Vérification des fuites d’air X1 Nettoyage de la partie externe du compresseur X Mettre le réservoir hors service X2 1 - Pour trouver des fuites d’air, appliquer une solution d’eau savonneuse autour des joints. Alors que le compresseur développe la pression et que l’accumulation de pression cesse, rechercher toute trace de bulles d’air. 2 - Pour plus d’informations, composer le 1-800-4-DeWALT (1‑800‑433‑9258). Vérification de la soupape de sûreté AVERTISSEMENT : risque d’éclatement. Si la soupape de sûreté ne fonctionne pas correctement, il peut se produire une surpressurisation, causant ainsi la rupture du réservoir d’air ou une explosion. AVERTISSEMENT : risque provenant des objets projet. És Toujours utiliser de l’équipement de sécurité homologué : protection oculaire conforme à la norme ANSI Z87.1 (CAN/CSA Z94.3) munie d’écrans latéraux lors de l’utilisation du compresseur. Avant de mettre en marche le compresseur, tirez sur la bague de la soupape de sûreté pour vous assurer que la soupape fonctionne librement. REMARQUE : il peut être difficile de tirer sur l’anneau si la pression du réservoir d’air est à 0 psi. Si la soupape est coincée ou ne fonctionne pas bien, il faut la remplacer par une soupape du même type. Vidange du réservoir d’air (Fig. 1) AVERTISSEMENT : risque d’utilisation dangereuse. Risque associé au bruit. Les réservoirs d’air contiennent de l’air sous haute pression. Éloigner le visage [ANSI Z87.1 (CAN/ CSA Z94.3)] et toutes autres parties du corps de l’orifice de vidange. Porter des lunettes de sécurité lors de la vidange car il y a risque de projection de débris au visage. AVERTISSEMENT : risques auditifs. Porter systématiquement une protection auditive appropriée durant l’utilisation. Sous certaines conditions et suivant la durée d’utilisation, le bruit émanant de ce produit pourrait contribuer à une perte de l’acuité auditive. REMARQUE : Tous les systèmes de compression d’air génèrent des condensats qui s’accumulent à un point de vidange (par ex., réservoir, filtre, dispositifs de postrefroidissement ou sécheur). Le condensat contient de l’huile lubrifiante ou des substances contrôlées, ou les deux, et doivent être éliminés conformément aux lois et règlements municipaux, provinciaux, territoriaux et fédéraux. AVERTISSEMENT : risque d’éclatement. Purger le réservoir d’air quotidiennement. L’eau se condensera dans le réservoir d’air. Si l’eau n’est pas vidangée, elle corrodera et affaiblira le réservoir d’air, provoquant ainsi un risque de rupture du réservoir d’air. AVIS : Risque de dégats matériels. Évacuez l'eau le réservoir d'air peut contenir l'huile et se rouiller qui peut causer des taches. 1. Assurez-vous que le mini-interrupteur (A) est sur la position ARRÊT (0). 2. Déposer un récipient convenable sous la soupape de purge pour recueillir les résidus. 3. Saisir le levier noir de la soupape de purge. 4. Tourner lentement le levier pour purger graduellement l’air du réservoir. 5. Une fois que le manomètre du réservoir affiche 10 psi, tourner complètement le levier en position ouverte. 6. Fermer la soupape de purge dès la fin de l’opération. Vérification des éléments du filtre d’air (Fig. 1) AVERTISSEMENT : surfaces chaudes. Risque de brûlure. Le postrefroidisseur, la tête de pompe et les pièces contiguës sont très chaudes – ne pas les toucher. Laisser refroidir le compresseur avant d’effectuer des réparations sur l’appareil. 1. Assurez-vous que le mini-interrupteur (A) est sur la position ARRÊT (0). 2. Permettez à l'unité de se refroidir. 3. Enlevez la couverture de filtre (J) de la base. 4. Enlevez l'élément de la base de filtre. 5. Placez le nouvel élément en arrière dans la base de filtre. Achetez les pièces de rechange de votre revendeur local ou centre commercial autorisé. Employez toujours les pièces de rechange identiques. 6. Couverture instantanée de filtre pour filtrer la base. AVIS: Risque d’utilisation dangereuse. Ne pas utiliser sans le filtre d’admission d’air. Accessoires AVERTISSEMENT : L’utilisation de tout autre accessoire non recommandé avec cet outil pourrait s’avérer dangereuse. Utiliser uniquement des accessoires de classement égal ou supérieur à celui de la compresseur d’air. Les accessoires recommandés pour votre outil peuvent être achetés auprès du distributeur local ou d’un centre de réparation agréé. Si vous avez besoin d’assistance pour trouver un accessoire pour votre outil, veuillez contacter DeWALT Industrial Tool Co., 701 East Joppa Road, Towson, MD 21286, États-Unis, composer le 1-800-4-DeWALT (1‑800‑433‑9258) ou visiter notre site Web à www.dewalt.com. reconocidas por el Estado de California como causantes de cáncer, defectos de nacimiento u otros problemas reproductivos. Lávese las manos después de utilizarlo. ADVERTENCIA: Algunos tipos de polvo contienen sustancias químicas, como el amianto y el plomo de las pinturas de base plomo, reconocidas por el Estado de California como causantes de cáncer, defectos de nacimiento u otros problemas. GUARDE ESTAS INSTRUCCIONES PELIGRO: RIESGO DE EXPLOSIÓN O INCENDIO ¿QUÉ PUEDE SUCEDER? Réparations • Es normal que los contactos eléctricos dentro del motor y el interruptor de presión produzcan chispas. • Si las chispas eléctricas del compresor entran en contacto con vapores inflamables, pueden encenderse, provocando un incendio o una explosión. Garantie complète d’un (1) an • Restringir cualquiera de las aberturas de ventilación del compresor puede producir un sobrecalentamiento grave y podría provocar un incendio. Information sur les réparations Veuillez recueillir les informations suivantes pour tous les appels au Service à la clientèle : Numéro du modèle ____________ Numéro de série _________________________________ Date et lieu de l’achat _______________________________________________________________ Pour assurer la SÉCURITÉ et la FIABILITÉ du produit, les réparations, l’entretien et les réglages doivent être réalisés par un centre de réparation en usine DeWALT, un centre de réparation agréé DeWALT ou par d’autres techniciens qualifiés. Toujours utiliser des pièces de rechange identiques. Les outils industriels de service intensif de DeWALT sont garantis pour une période de un (1) an à partir de la date d’achat. DeWALT réparera gratuitement toutes défectuosités provoquées par un défaut de matériel ou de fabrication. Pour des renseignements relatifs aux réparations sous garantie, composer le 1-800-4-DeWALT (1‑800‑433‑9258). Cette garantie ne s’applique pas aux accessoires ni aux dommages causés par des réparations réalisées ou tentées par des tiers. Cette garantie vous accorde des droits légaux spécifiques et il est possible que vous ayez d’autres droits qui varient d’un État ou d’une province à l’autre. AMÉRIQUE LATINE : cette garantie ne s’applique pas aux produits vendus en Amérique latine. Pour ceux-ci, veuillez consulter les informations relatives à la garantie spécifique présente dans l’emballage, appeler l’entreprise locale ou consulter le site Web pour les informations relatives à cette garantie. REMPLACEMENT GRATUIT DES ÉTIQUETTES D’AVERTISSEMENT (Fig. 4) : si les étiquettes d’avertissement deviennent illisibles ou sont manquantes, composer le 1-800-4-DeWALT (1‑800‑433‑9258) pour en obtenir le remplacement gratuit. GLOSSAIRE CFM : pied cube par minute. SCFM : pied cube par minute (standard), une unité de mesure du soufflage. PSI : livres par pouce carré, une unité de mesure de pression. kPa (kilopascal) : unité de mesure de pression. 1 kilopascal est égal à 1000 pascals. Codes de certification : les produits portant une ou plusieurs des mentions suivantes (UL®, CUL, CULUS, ETL®, CETL, CETLUS) ont été évalués par des laboratoires indépendants de sécurité certifiés par l'OSHA et répondent aux normes de sécurité applicables. *UL® est une marque de commerce déposée d’Underwriters Laboratories et ETL® est une marque de commerce déposée d’Electrical Testing Laboratories. Pression d’enclenchement : lorsque le moteur est éteint, la pression du réservoir d’air chute quand vous continuez à utiliser votre accessoire. Lorsque la pression du réservoir chute pour atteindre un niveau bas, le moteur se remet en marche automatiquement. La basse pression à laquelle le moteur se remet en marche automatiquement est appelée pression d’enclenchement. Pression de déclenchement : lorsqu’un compresseur d’air est mis sous tension et se met à fonctionner, la pression d’air dans le réservoir d’air commence à s’accumuler. Une haute pression s’accumule avant que le moteur se mette automatiquement hors tension en protégeant votre réservoir d’air d’une pression supérieure à sa capacité. La haute pression à laquelle le moteur se met hors tension est appelée pression de déclenchement. Circuit de dérivation : le circuit qui transporte de l’électricité du panneau électrique à la prise. Cycle de travail : cette pompe du compresseur d’air peut fonctionner en continu. Cependant, pour prolonger la durée de vie de votre compresseur, il est recommandé de maintenir un cycle de travail de 50 % à 75 % en moyenne, donc que la pompe du compresseur ne doit pas fonctionner plus de 30 à 45 minutes par heure. Guide de dépannage Cette section énumère les défaillances les plus communes, leurs causes et les mesures correctives. L’opérateur ou le personnel d’entretien peut exécuter certaines mesures correctives, d’autres exigent l’assistance d’un technicien DeWALT qualifié ou du distributeur. Problème Code Pression excessive dans le réservoir d’air - la soupape de sûreté claque .................. 1, 2 Fuites d’air ............................................................................................................................ 3 Fuites d’air dans le réservoir d’air ou dans les soudures du réservoir d’air..................... 4 Fuites d’air entre la tête et la plaque porte-soupapes....................................................... 5 Fuites d’air à la soupape de sûreté..................................................................................... 6 Cliquetis................................................................................................................................. 6 Le relevé de pression sur le manomètre réglementé chute lorsque l’accessoire est utilisé............................................................................................. 7 Le compresseur ne fournit pas la quantité d’air requise pour le fonctionnement d’accessoires......................................8, 9, 10, 11, 12, 22 Fuite d’air continuelle au bouton du régulateur................................................................ 13 Le régulateur ne parvient pas à fermer la sortie d’air....................................................... 13 Pompe refuse de fonctionner.................................................. 6, 14, 15, 16, 17, 18, 19, 20 Sifflement............................................................................................................................. 21 Codes de dépannage CODE CAUSE PROBABLE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Le manocontacteur n’éteint pas le moteur lorsque le compresseur atteint la pression de déclenchement La pression de l’interrupteur de déclenchement est trop élevée Les raccords de tube ne sont pas assez serrés SOLUTION PROBABLE Réglez le mini-interrupteur sur ARRÊT (0), si l’appareil ne s’éteint pas, contacter un centre de réparation en usine de DeWALT ou un centre de réparation agréé DeWALT. Communiquer avec un centre de réparation en usine de DeWALT ou un centre de réparation agréé DeWALT. Serrer les raccords qui émettent un sifflement de fuite d’air. Contrôler les raccords avec une solution d’eau savonneuse. Ne serrez pas trop. Réservoir d’air défectueux Le réservoir d’air doit être remplacé. Ne pas réparer la fuite. AVERTISSEMENT : Risque d’éclatement. Ne pas percer le réservoir d’air, ni le souder ou le modifier de quelque manière qui soit. Ces interventions l’affaibliront. Le réservoir risque de rompre ou d’exploser. Joints d’étanchéité fuyants Communiquer avec un centre de réparation en usine de DeWALT ou un centre de réparation agréé DeWALT. Soupape de sûreté défectueuse Faites fonctionner la soupape manuellement en tirant sur la bague. Si la soupape fuit toujours, la remplacer. Le régulateur n’est pas réglé Il est normal que la pression chute lorsqu’un accessoire correctement pour l’accessoire est utilisé, ajuster le régulateur comme indiqué sous utilisé Caractéristiques si la pression chute trop. REMARQUE : Régler la pression régulée sous des conditions de travail avec l’utilisation de l’accessoire. Utilisation excessive prolongée Diminuer la quantité d’air utilisée. de l’air Le compresseur ne dispose pas Vérifier les exigences d’air de l’accessoire. Si elles de la capacité adéquate pour sont supérieures au CFM ou à la pression fournie par l’utilisation d’accessoires le compresseur d’air, un compresseur de plus grande capacité est requis pour l’utilisation de l’accessoire. Trou dans le tuyau d’air Remplacer le tuyau d’air. Clapet obstrué Communiquer avec un centre de réparation en usine de DeWALT ou un centre de réparation agréé DeWALT. Fuites d’air Serrez les raccords. Le régulateur est endommagé Le remplacer. Le commutateur de protection Consulter la rubrique Surcharge du moteur sous de surcharge du moteur a été Caractéristiques. Si la protection de surcharge de moteur déclenché se déclenche fréquemment, Communiquer avec un centre de réparation en usine de DeWALT ou un centre de réparation agréé DeWALT. La pression du réservoir excède Le moteur démarre automatiquement lorsque la pression la pression d'enclenchement du du réservoir chute sous la pression d’enclenchement. commutateur La rallonge n’a pas la bonne Vérifier la bonne longueur ou épaisseur du cordon. longueur ou épaisseur Consulter la rubrique Rallonges sous Installation. Raccords électriques lâches Communiquer avec un centre de réparation en usine de DeWALT ou un centre de réparation agréé DeWALT. Possibilité d’un moteur Communiquer avec un centre de réparation en usine de DeWALT ou un centre de réparation agréé DeWALT. Présence de peinture sur les Communiquer avec un centre de réparation en usine pièces internes du moteur de DeWALT ou un centre de réparation agréé DeWALT. Ne pas faire fonctionner le compresseur dans une zone de pulvérisation de peinture. Lire l’avertissement concernant les vapeurs inflammables. Fusible grillé, disjoncteur 1. Vérifiez la boîte à fusibles et remplacez les fusibles, déclenché au besoin. Remettre le disjoncteur à zéro . N’utilisez pas un fusible ou un disjoncteur ayant une puissance nominale supérieure à ce qui est précisé pour votre circuit de dérivation. 2. Vérifiez s’il s’agit du bon fusible. Utilisez seulement des fusibles temporisés. 3. Vérifiez s’il y a un problème de basse tension et/ou de mauvaise rallonge. 4. Débranchez les autres appareils électriques du circuit ou faites fonctionner le compresseur sur son propre circuit de dérivation. Courroie usée Communiquer avec un centre de réparation en usine de DeWALT ou un centre de réparation agréé DeWALT. Filtre d’admission d’air obstrué Nettoyer ou remplacer le filtre d’admission d’air. Ne pas utiliser le compresseur d’air sans le filtre. Se reporter au paragraphe relatif au filtre à air de la rubrique Entretien. • El funcionamiento sin atención de este producto podría provocar lesiones personales o daños a la propiedad. Para disminuir el riesgo de incendio, no permita que el compresor funcione sin que alguien lo controle. PELIGRO: RIESGO RESPIRATORIO (ASFIXIA) ¿QUÉ PUEDE SUCEDER? CÓMO EVITARLO • El aire comprimido que sale de su compresor no es seguro para respirarlo. El flujo de aire puede contener monóxido de carbono, vapores tóxicos o partículas sólidas del tanque de aire. Respirar estos contaminantes puede provocar lesiones graves o la muerte. • El aire que se obtiene directamente del compresor no se debe usar nunca para consumo humano. El compresor no incluye equipo de seguridad en línea y filtros adecuados para consumo humano. • La exposición a productos químicos en el polvo producido por las herramientas eléctricas al lijar, aserrar, esmerilar, taladrar y otras actividades de la construcción puede ser peligrosa. • Los materiales pulverizados como pintura, solventes para pinturas, removedor de pintura, insecticidas y herbicidas pueden contener vapores dañinos y venenos. • Trabaje en un área con buena ventilación cruzada. Lea y siga las instrucciones de seguridad que se proveen en la etiqueta o en la ficha técnica de los materiales que está utilizando. Siempre utilice equipamiento de seguridad certificado: protección respiratoria aprobada por NIOSH/OSHA o una mascarilla facial adecuada diseñada para usar para los fines que usted requiere. ADVERTENCIA: RIESGO DE EXPLOSIÓN Tanque de aire: El 26 de febrero de 2002, la Comisión de Seguridad para Productos de Consumo delos Estados Unidos publicó el Comunicado # 02-108 sobre la seguridad en los tanques de compresores de aire: Los tanques receptores de los compresores de aire no tienen una vida útil infinita. La vida útil del tanque depende de diversos factores, incluyendo las condiciones de operación, las condiciones ambientales, la instalación debida del mismo, modificaciones realizadas en el campo y el nivel de mantenimiento que reciba. Es difícil prever cuál será el efecto exacto de estos factores sobre la vida útil del tanque receptor de aire. Si no se siguen procedimientos de mantenimiento debidos, la corrosión interna de la pared interior del tanque receptor de aire puede causar una ruptura imprevista en el tanque de aire, lo que hará que el aire presurizado escape con fuerza y repentinamente, pudiendo lesionar al usuario. El tanque de su compresor de aire debe ser dado de baja al final del año que aparece en la etiqueta de advertencia de su tanque. Las siguientes condiciones pueden llevar a debilitar el tanque de aire y ocasionar la explosión violenta del mismo: ¿QUÉ PUEDE SUCEDER? CÓMO EVITARLO • No drenar correctamente el agua condensada • Drene el tanque diariamente o luego de cada uso. del tanque de aire, que provoca óxido y adelSi un tanque de aire presenta una pérdida, reemgazamiento del tanque de aire de acero. plácelo inmediatamente con un tanque nuevo o reemplace todo el compresor. • Modificaciones o intento de reparación del tanque de aire. • Nunca perfore, suelde o haga ninguna modificación al tanque de aire o a sus elementos. Nunca intente reparar un tanque de aire dañado o con pérdidas. Reemplácelo con un tanque de aire nuevo. • Las modificaciones no autorizadas de la válvula de seguridad o cualquier otro componente que controle la presión del tanque. • El tanque está diseñado para soportar determinadas presiones de operación. Nunca realice ajustes ni sustituya piezas para cambiar las presiones de operación fijadas en la fábrica. Elementos y accesorios: • Exceder las indicaciones de presión para las herramientas neumáticas, las pistolas pulverizadoras, los accesorios neumáticos, los neumáticos y otros artículos inflables puede hacer que exploten o revienten, y puede provocar lesiones graves. Neumáticos: • El inflado excesivo de los neumáticos podría causar lesiones graves y daño a la propiedad. SI TIENE ALGUNA DUDA O ALGÚN COMENTARIO SOBRE ÉSTA U OTRA HERRAMIENTA DeWALT, LLÁMENOS AL NÚMERO GRATUITO: 1-800-4-DeWALT (1-800-433-9258) Instrucciones de seguridad importantes ADVERTENCIA: No opere esta unidad hasta que haya leído este manual de instrucciones de seguridad, operación y mantenimiento. ADVERTENCIA: Este producto contiene sustancias químicas, incluido el plomo, • Siga la recomendación del fabricante del equipo y nunca exceda el nivel máximo de presión aceptable para los elementos. Nunca utilice el compresor para inflar objetos pequeños de baja presión, tales como juguetes de niños, pelotas de fútbol o de basquetbol, etc. • Utilice un medidor de presión de neumáticos para controlar la presión de éstos antes de cada uso y mientras los infla; observe el flanco para ver la presión correcta del neumático. NOTA: Los tanques de aire, los compresores y el equipo similar que se usa para inflar neumáticos pueden llenar neumáticos pequeños como éstos con mucha rapidez. Ajuste el regulador de presión en el suministro de aire a un valor que no supere el de la presión del neumático. Agregue aire en forma gradual y use con frecuencia el medidor de presión de neumáticos para evitar inflarlos. ADVERTENCIA: RIESGO DE DESCARGA ELÉCTRICA ¿QUÉ PUEDE SUCEDER? CÓMO EVITARLO • Su compresor de aire funciona con electricidad. Como cualquier otro mecanismo que funciona con electricidad, si no se lo utiliza correctamente puede provocar descargas eléctricas. • Que personal no calificado intente realizar reparaciones puede provocar lesiones graves o muerte por electrocución. • Puesta a tierra: La no colocación de la puesta a tierra adecuada para este producto puede provocar lesiones graves o muerte por electrocución. Consulte las Instrucciones de Conexión a tierra en Instalación. • Nunca haga funcionar el compresor al aire libre cuando está lloviendo o en condiciones de humedad. • Nunca haga funcionar el compresor sin las cubiertas de protección o si están dañadas. • Cualquier cableado eléctrico o las reparaciones requeridas para este producto deben ser realizadas por un centro de servicio de fábrica DeWALT o un centro de mantenimiento autorizado DeWALT de acuerdo con los códigos eléctricos nacionales y locales. • Asegúrese de que el circuito eléctrico al que se conecta el compresor suministre la conexión a tierra adecuada, el voltaje adecuado y el fusible de protección adecuado. ADVERTENCIA: RIESGO DE OBJETOS DESPEDIDOS ¿QUÉ PUEDE SUCEDER? • La corriente de aire comprimido puede provocar lesiones en los tejidos blandos de la piel expuesta y puede impulsar suciedad, astillas, partículas sueltas y objetos pequeños a gran velocidad, que pueden producir daños en la propiedad y lesiones personales. CÓMO EVITARLO • Utilice siempre equipo de seguridad certificado: anteojos de seguridad ANSI Z87.1 (CAN/CSA Z94.3) con protección lateral al usar el compresor. • Nunca apunte ninguna boquilla ni pulverizador a ninguna parte del cuerpo o a otras personas o animales. • Apague siempre el compresor y drene la presión de la manguera de aire y del tanque de aire antes de intentar hacer mantenimiento, conectar herramientas o accesorios. ADVERTENCIA: RIESGO DE SUPERFICIES CALIENTES ¿QUÉ PUEDE SUCEDER? CÓMO EVITARLO • Tocar metal expuesto como el cabezal del compresor, el cabezal del motor, el escape del motor, o los tubos de salida puede provocar quemaduras graves. • Nunca toque ninguna parte metálica expuesta del compresor durante o inmediatamente después de su funcionamiento. El compresor continuará caliente durante varios minutos después de su funcionamiento. • No toque las cubiertas protectoras ni intente realizar mantenimiento hasta que la unidad se haya enfriado. ADVERTENCIA: RIESGO POR PIEZAS MÓVILES ¿QUÉ PUEDE SUCEDER? CÓMO EVITARLO • Las piezas móviles como la polea, el volante y la correa pueden provocar lesiones graves si entran en contacto con usted o con sus ropas. Definiciones: Normas de seguridad Las siguientes definiciones describen el nivel de gravedad de cada advertencia. Lea el manual y preste atención a estos símbolos. PELIGRO: Indica una situación de peligro inminente que, si no se evita, provocará la muerte o lesiones graves. ADVERTENCIA: Indica una situación de peligro potencial que, si no se evita, podría provocar la muerte o lesiones graves. ATENCIÓN: Indica una situación de peligro potencial que, si no se evita, puede provocar lesiones leves o moderadas. AVISO: Se refiere a una práctica no relacionada a lesiones corporales que de no evitarse puede resultar en daños a la propiedad. CÓMO EVITARLO • Opere siempre el compresor en un área bien ventilada libre de materiales combustibles, gasolina o vapores de solventes. • Si se pulverizan materiales inflamables, ubique el compresor al menos a 6,1 m (20 pies) del área de pulverización. Se puede necesitar manguera adicional. • Guarde los materiales inflamables en lugar seguro lejos del compresor. • Nunca coloque objetos contra o sobre la bomba del compresor. • Opere el compresor en un lugar abierto con una distancia de al menos 30,5 cm (12 ") a cualquier pared u obstrucción que pudiera restringir el flujo de aire fresco a las aberturas de ventilación. • Opere el compresor en un área limpia, seca y bien ventilada. No opere la unidad dentro de la casa o en un área muy cerrada. • Permanezca siempre controlando el producto cuando está en funcionamiento. • Siempre apague y desenchufe la unidad cuando no esté en uso. • Intentar hacer funcionar el compresor con partes dañadas o faltantes, o intentar reparar el compresor sin las cubiertas protectoras puede exponerlo a piezas móviles lo que puede provocar lesiones graves. • Nunca haga funcionar el compresor sin los protectores o cubiertas o si los mismos están dañados. • Mantenga el cabello, la ropa y los guantes alejados de las piezas en movimiento. Las ropas holgadas, las joyas o el cabello largo pueden quedar atrapados en las piezas móviles. • Los orificios de ventilación pueden cubrir piezas en movimiento, por lo que también se deben evitar. • Cualquier reparación requerida por este producto debe ser realizada por un centro de servicio de fábrica DeWALT o un centro de servicio autorizado DeWALT. ADVERTENCIA: RIESGO DE OPERACIÓN INSEGURA ¿QUÉ PUEDE SUCEDER? CÓMO EVITARLO • La operación insegura de su compresor de aire podría producir lesiones graves o la muerte, a usted mismo o a otras personas. • Revise y comprenda todas las instrucciones y advertencias de este manual. • Familiarícese con la operación y los controles del compresor de aire. • Mantenga el área de operaciones libre de personas, mascotas y obstáculos. • Mantenga a los niños alejados del compresor de aire en todo momento. • No opere el producto cuando esté cansado o bajo la influencia de alcohol o drogas. Manténgase alerta en todo momento. • Nunca anule las características de seguridad de este producto. • Equipe el área de operaciones con un extintor de incendios. • No opere la máquina si faltan piezas, si éstas están rotas o si no son las autorizadas. ADVERTENCIA: RIESGO DE CAÍDAS ¿QUÉ PUEDE SUCEDER? CÓMO EVITARLO • Un compresor portátil se puede caer de una mesa, banco o techo, provocando daños al compresor y puede producir lesiones graves o la muerte del operador. • Opere siempre el compresor en una posición estable y segura para evitar que la unidad se mueva accidentalmente. Nunca opere el compresor sobre un techo u otra ubicación elevada. Utilice una manguera de aire adicional para alcanzar las ubicaciones elevadas. ADVERTENCIA: RIESGO DE LESIÓN POR LEVANTAR MUCHO PESO ¿QUÉ PUEDE SUCEDER? CÓMO EVITARLO • El intento de levantar un objeto muy pesado puede provocar lesiones graves. • El compresor es demasiado pesado como para que lo levante una sola persona. Consiga ayuda de otras personas para levantarlo. ADVERTENCIA: RIESGO POR RUIDOS ¿QUÉ PUEDE SUCEDER? CÓMO EVITARLO • En determinadas condiciones y según el período de uso, el ruido provocado por este producto puede originar pérdida de audición. • Utilice siempre protección auditiva apropiada al usar esta herramienta. CONSERVE ESTAS INSTRUCCIONES PARA FUTURAS CONSULTAS Componentes (Fig. 1) A. Mini interruptor G. B. Manómetro del tanque de aire H. C. Manómetro regulado D. Regulador de presión I. E. Conectores rápidos F. Válvula de control Válvula de seguridad Válvula de drenaje del tanque de aire Filtro de entrada de aire CARACTERÍSTICAS (FIG. 1) MINI INTERRUPTOR Ponga este interruptor (A) en la posición de encendido (ON(I)) para poner en marcha la unidad y en la de apagado (OFF(0)) para desconectar la alimentación al final de cada uso. INTERRUPTOR DE PRESIÓN El interruptor de presión arranca automáticamente el motor cuando la presión del tanque de aire cae por debajo de la presión de arranque fijada en fábrica. Detiene el motor cuando la presión del tanque de aire alcanza la presión de corte fijada en fábrica. VÁLVULA DE SEGURIDAD Si el interruptor de presión no apaga el compresor de aire en su punto de presión de corte, la válvula de seguridad (G) protegerá contra la presión alta saltando a la presión fijada en fábrica (ligeramente mayor que la fijada para el corte del interruptor de presión). VÁLVULA DE CONTROL Cuando el compresor de aire está funcionando, la válvula de control (F) está abierta, permitiendo al aire comprimido entrar al tanque de aire. Cuando el compresor de aire alcanza la presión de corte, la válvula de control se cierra, permitiendo que la presión de aire se conserve dentro del tanque de aire. MANÓMETRO (MEDIDOR DE PRESIÓN) DEL TANQUE El manómetro (medidor de presión) del tanque (B) indica la presión de aire de reserva en el tanque. MANÓMETRO (MEDIDOR DE PRESIÓN) DE SALIDA El manómetro (medidor de presión) de salida (C) indica la presión del aire disponible en la salida del regulador. Esta presión la controla el regulador. REGULADOR La regulador (D) controla la presión de aire mostrada en el manómetro de salida. Tire de la perilla y gírela en sentido horario para incrementar la presión, y hágalo en sentido inverso para disminuirla. Cuando se logre la presión deseada, presione la perilla para bloquearla. The regulated pressure range is 7–150 psi. ADVERTENCIA: Riesgo de explosión. Demasiada presión de aire produce peligro de estallido. Controle el valor nominal máximo de presión del fabricante para las herramientas y los accesorios neumáticos. La presión de salida del regulador nunca debe exceder el valor máximo de presión. CONECTORE RÁPIDO UNIVERSALE El conector rápido universal (E) acepta los tres estilos más populares de enchufes de conexión rápida: Industrial, para automóviles y ARO. “Empujar para conectar” con una sola mano, esta operación hace que las conexiones sean más simples y fáciles. Los dos conectores rápidos permiten la utilización de dos herramientas al mismo tiempo. VÁLVULA DE DRENAJE La válvula de drenaje (H) está ubicada en la base del tanque de aire y se utiliza para drenar la condensación al terminar cada etapa de uso. Consulte Drenar el tanque de aire en la sección Mantenimiento. SISTEMA DE ENFRIAMIENTO Este compresor tiene un sistema de enfriamiento de diseño avanzado. Es normal que este ventilador sople aire a través de los orificios de ventilación en cantidades importantes. El sistema de enfriamiento está funcionando cuando se expulsa aire. BOMBA DEL COMPRESOR DE AIRE La bomba comprime el aire en el tanque de aire. No hay aire para trabajar hasta que el compresor no ha elevado la presión del tanque de aire por encima de la requerida en la salida de aire. FILTRO DE ENTRADA DE AIRE El filtro (I) está diseñado para limpiar el aire que ingresa a la bomba. Para asegurar que la bomba reciba continuamente un suministro de aire limpio, fresco y seco, el filtro debe estar siempre limpio y la entrada del filtro libre de obstrucciones. PROTECTOR DE SOBRECARGA DEL MOTOR El motor tiene un protector de sobrecarga térmica. Si el motor se recalienta por alguna razón, el protector de sobrecarga apagará el motor. Se debe permitir que el motor se enfríe antes de volver a encenderlo. Para volver a encenderlo: 1. Ponga el mini interruptor (A) en apagado (OFF(0)) y desenchufe la unidad. 2. Espere que el motor se enfríe. 3. Enchufe el cable eléctrico en el receptáculo apropiado del circuito de derivación. 4. Ponga el mini interruptor en la posición de encendido (ON(I)). INSTALACIÓN Ensamblaje INSTALACIÓN DE LAS MANGUERAS ADVERTENCIA: Riesgo de operación insegura. Sostenga la manguera firmemente con las manos al instalarla o desconectarla para evitar la desconexión repentina de la manguera. 1. Asegúrese de que el manómetro regulado marque 0 psi. 2. Tome la manguera por el enchufe de conexión rápida y empuje el enchufe en el conector rápido (E). El acople quedará en la posición correcta. 3. Tome la manguera y tire de ella para asegurarse de que el acople esté bien colocado. DESCONEXIÓN DE LAS MANGUERAS ADVERTENCIA: Riesgo de operación insegura. Sostenga la manguera firmemente con las manos al instalarla o desconectarla para evitar la desconexión repentina de la manguera. 1. Asegúrese de que el manómetro regulado marque 0 psi. 2. Del conector rápido, tire el acople hacia atrás para liberar el enchufe de conexión rápida de la manguera. MONTAJE DE LAS RUEDAS (FIG. 4) 1. Introduzca el perno a través de la rueda y el soporte como se muestra en la Fig. 4. 2. Sujetando la tuerca de fijación en su sitio con una llave, ajuste el perno de la rueda firmemente. 3. Repita estos pasos para la rueda opuesta. MONTAJE DE LOS TOPES (FIG. 5) 1. Introduzca el perno roscado a través del aislador y enrósquelo en el orificio del soporte, como se muestra en la Fig. 5. Ajuste bien el perno. 2. Repita estos pasos para el tope opuesto. Instrucciones de conexión a tierra (Fig. 2) ADVERTENCIA: Riesgo de descarga eléctrica. En el caso de cortocircuito, la puesta a tierra reduce el riesgo de descarga eléctrica al proveer un cable de escape para la corriente eléctrica. Este compresor de aire debe estar correctamente conectado a tierra. El compresor de aire portátil está equipado con un cable que tiene un cable a tierra con el enchufe a tierra apropiado. 1. El juego de cable y enchufe (M) de esta unidad tiene una pata a tierra (L). Este enchufe SE DEBE usar con un tomacorriente con puesta a tierra (K). IMPORTANTE: El tomacorriente que se utiliza debe estar instalado y puesto a tierra de acuerdo con todos los códigos y ordenanzas locales. 2. Asegúrese de que el tomacorriente que se utiliza tenga la misma configuración que el enchufe a tierra. NO UTILICE UN ADAPTADOR. 3. Inspeccione el enchufe y el cable cada vez que vaya a utilizarlo. No lo utilice si hay señales de daño. 4. Si no se comprenden completamente estas instrucciones de puesta a tierra, o si tiene dudas sobre si el compresor está puesto a tierra correctamente, haga que un electricista calificado controle la instalación. PELIGRO: Riesgo de descarga eléctrica. UNA PUESTA A TIERRA INCORRECTA PUEDE PROVOCAR UNA DESCARGA ELÉCTRICA. • No modifique el enchufe provisto. Si no coincide con el tomacorriente disponible, un electricista calificado debe instalar un tomacorriente apropiado. • Las reparaciones del cable o del enchufe deben ser realizadas por un electricista calificado. Cables prolongadores Si - no obstante - debe utilizarse una extensión de cable, asegúrese de que: • La extensión eléctrica de 3 conductores, tenga un enchufe de conexión a tierra de 3 hojas, y que exista un receptáculo que acepte el enchufe del producto. • Esté en buenas condiciones. • No más largo que 15,2 m (50 pies). • Calibre 12 (AWG) o mayor. (La medida de los cables se incrementa a medida que su número ordinal decrece. 10 y 8 AWG pueden ser usados también. NO USE 14 NI 16 AWG). AVISO: Riesgo de daño a la propiedad. El uso de cables de extensión eléctrica originará una caída de tensión, lo que determinará una pérdida de potencia del motor así como su recalentamiento. En lugar de utilizar un cable de extensión eléctrica, incremente el alcance de la manguera de aire dentro de la zona de trabajo, añadiéndole otro largo de manguera a su extremo. Conecte los largos adicionales de manguera de acuerdo a su necesidad. Voltaje y protección del circuito Consulte el voltaje y los requisitos mínimos del circuito de derivación en la sección Especificaciones. ATENCIÓN: Existe riesgo de sobrecalentamiento. Ciertos compresores de aire se pueden operar mediante un circuito de 15 A si se cumplen las siguientes condiciones • El suministro de voltaje al circuito debe cumplir con el Código de Electricidad Nacional. • El circuito no se utiliza para cubrir ninguna otra necesidad de electricidad. • Los cables prolongadores cumplen con las especificaciones. • El circuito está equipado con un disyuntor de 15 A mínimo o un fusible de acción retardada de 15 A. NOTA: Si el compresor está conectado a un circuito protegido con fusibles, utilice únicamente fusibles de acción retardada. Los fusibles de acción retardada deben estar marcados “D” en Canadá y “T” en EE.UU. Si no se puede cumplir alguna de las condiciones indicadas anteriormente, o si el funcionamiento del compresor provoca repetidas interrupciones de energía, puede ser necesario hacerlo funcionar con un circuito de 20 A. No es necesario cambiar el cable. Compatibilidad NOTA: Utilice siempre un filtro de línea de aire para eliminar la humedad y el vapor de aceite al pulverizar pintura. Lugar Coloque el compresor de aire en un área limpia, seca y bien ventilada a una distancia de al menos 30,5 cm (12 ") de la pared o cualquier obstrucción que interfieran con el flujo de aire. Mantenga el compresor alejado de áreas que tengan suciedad y/o humo volátil en la atmósfera. Estas impurezas puedan atascar el filtro de entrada y las válvulas, provocando un funcionamiento ineficiente. ADVERTENCIA: La bomba y la cubierta del compresor de aire están diseñadas para permitir un enfriamiento correcto. Las aberturas de ventilación del compresor son necesarias para mantener la temperatura de operación correcta. No coloque trapos u otros recipientes sobre o cerca de estas aberturas. Coloque el compresor de aire en una superficie plana apoyado sobre las patas y ruedas de goma. ELÉCTRICAS Consulte todas las instrucciones de seguridad antes de utilizar la unidad. Observe las instrucciones de seguridad del cable prolongador, de ser necesario. Ponga siempre el interruptor (A) en la posición de apagado (OFF(0)) antes de retirar el enchufe de la toma de corriente. TRANSPORTE (FIG. 3) Al transportar el compresor en un vehículo, remolque, etc., asegúrese de que el tanque se haya drenado y que la unidad esté asegurada y colocada. Maneje con cuidado para evitar que la unidad se incline en el vehículo. El compresor o los elementos circundantes se pueden dañar si el compresor se inclina. LEVANTAR LA UNIDAD Utilice siempre dos personas cuando levante la unidad y levántela desde los puntos recomendados (N). NO LEVANTE tomando la unidad de las ruedas o la cubierta. TRASLADAR LA UNIDAD ATENCIÓN: Las ruedas y la agarradera no brindan espacio, estabilidad ni apoyo adecuados para subir o bajar la unidad por escaleras o escalones. La unidad se debe levantar, o empujar sobre una rampa. 1. Tome la agarradera del compresor e incline el compresor hacia atrás para que se apoye en las ruedas. ADVERTENCIA: Riesgo de operación insegura. Asegure el punto de apoyo adecuado y tenga precaución al desplazar el compresor de manera que la unidad no se incline ni pierda el equilibrio. 2. Cuando llegue al lugar deseado, baje lentamente compresor hacia el piso. Siempre guarde el compresor en posición vertical apoyado sobre protectores de goma y ruedas. PREPARACIÓN PARA EL USO ADVERTENCIA: No opere esta unidad hasta que haya leído este manual de instrucciones de seguridad, operación y mantenimiento. Lista de control previa a la puesta en marcha (Fig. 1) 1. Asegúrese de que el mini interruptor (A) esté en la posición de apagado (OFF(0)). 2. Enchufe el cable eléctrico en el receptáculo apropiado del circuito de derivación. Consulte Voltaje y protección del circuito en la sección Instalación. 3. Asegúrese de que el tanque de aire se haya drenado, consulte Drenar el tanque de aire en la sección Mantenimiento. 4. Asegúrese de que la válvula de drenaje (H) esté cerrada. 5. Asegúrese de que la válvula de seguridad (G) funcione correctamente, consulte Controlar la válvula de seguridad en la sección Mantenimiento. 6. Tire de la perilla del regulador (D) et gire la perilla en sentido contrario a las agujas del reloj hasta que esté completamente cerrada. Asegúrese de que el manómetro regulado marque 0 psi. Presione la perilla para bloquearla. 7. Conecte la manguera y los accesorios. NOTA: use siempre una manguera de aire de un mínimo de 9,5 mm (3/8 ") o mayor con una capacidad nominal de 300 psi. ADVERTENCIA: Riesgo de operación insegura. Sostenga la manguera firmemente con las manos al instalarla o desconectarla para evitar la desconexión repentina de la manguera. ADVERTENCIA: Riesgo de operación insegura. No utilice los accesorios dañados o usados. ADVERTENCIA: Riesgo de explosión. Demasiada presión de aire produce peligro de estallido. Controle el valor nominal máximo de presión del fabricante para las herramientas y los accesorios neumáticos. La presión de salida del regulador nunca debe exceder el valor máximo de presión. PROCEDIMIENTOS OPERATIVOS Puesta en marcha (Fig. 1) 1. Siga la Lista de control previa a la puesta en marcha en la sección Preparación para el uso. 2. Mueva el interruptor a la posición de encendido (ON(I)) y deje que aumente la presión del tanque. El motor se detendrá cuando la presión del tanque alcance la presión de corte. AVISO: Riesgo de daño a la propiedad. El aire comprimido de la unidad puede contener condensación de agua y emanación de aceite. No pulverice aire no filtrado sobre un artículo que podría dañarse con la humedad. Algunos dispositivos o herramientas neumáticas pueden requerir aire filtrado. Lea las instrucciones del dispositivo o la herramienta neumática. 3. Ajuste el regulador (D) en la configuración deseada. Consulte el punto Regulador en la sección Características. Apagado (Fig. 1) 1. Mueva el mini interruptor (A) a la posición de apagado (OFF(0)). NOTA: Si terminó de utilizar el compresor, siga los pasos 2 a 6. NOTA: Cuando se apagó la unidad, es normal que se escuche un silbido breve que indica la salida de aire. NOTA: Desenchufe la unidad de la toma de corriente cuando no esté en uso. 2. Tire de la perilla del regulador (D) et gire en sentido contrario a las agujas del reloj hasta que esté completamente cerrada. Asegúrese de que el manómetro regulado marque 0 psi. Presione la perilla para bloquearla. 3. Retire la manguera y los accesorios. ADVERTENCIA: Riesgo de operación insegura. Sostenga la manguera firmemente con las manos al instalarla o desconectarla para evitar la desconexión repentina de la manguera. 4. Drene el tanque de aire, consulte Drenar el tanque de aire en la sección Mantenimiento. Asegúrese de que el manómetro regulado marque 0 psi. ADVERTENCIA: Riesgo de explosión. Drene el tanque de aire diariamente. El agua se condensará en el tanque de aire. Si no se drena, el agua corroerá y debilitará al tanque de aire provocando el riesgo de rotura del mismo. 5. Deje enfriar el compresor. 6. Limpie el compresor de aire y guárdelo en un área segura, que no se congele. MANTENIMIENTO Se deben seguir los siguientes procedimientos cuando se realicen tareas de mantenimiento o servicio en el compresor de aire. 1. Asegúrese de que el mini interruptor (A) esté en la posición de apagado (OFF(0)). 2. Retire el enchufe del compresor de aire del tomacorriente. 3. Drene el tanque de aire. 4. Deje enfriar el compresor de aire antes de comenzar las tareas de mantenimiento. NOTA: Todos los sistemas de aire comprimido contienen piezas de mantenimiento (por ejemplo, aceite, filtros, separadores) que se reemplazan periódicamente. Estas piezas usadas pueden contener sustancias reguladas y se deben desechar conforme a las leyes y reglamentaciones locales, estatales y federales. NOTA: Tome nota de las posiciones y ubicaciones de las piezas durante el desarmado para facilitar el reensamblaje. NOTE: Cualquier tarea de mantenimiento no incluida en esta sección debe ser realizada por un centro de servicio de fábrica DeWALT o un centro de servicio autorizado DeWALT. Tabla de mantenimiento Procedimiento Controlar la válvula de seguridad Inspeccionar el filtro de aire Drenar el tanque de aire Controlar ruidos o vibraciones inusuales Verificar si hay pérdidas de aire Limpiar el exterior del compresor Diariamente Semanal- Remítase a la etiqueta de mente advertencia del tanque X X X X X1 X El tanque debe ser dado de baja X2 1 - Para verificar si hay pérdidas de aire aplique una solución de agua jabonosa alrededor de las juntas. Mientras el compresor bombea para generar presión y luego de que la presión se corte, vea si se forman burbujas de aire. 2 - Para mayor información, llame al 1- 800-4-DeWALT (1-800-433-9258) Controlar la válvula de seguridad ADVERTENCIA: Riesgo de explosión. Si la válvula de seguridad no trabaja correctamente, puede haber sobrepresurización, provocando la rotura del tanque de aire o una explosión. ADVERTENCIA: Riesgo de objetos despedidos. Utilice siempre equipo de seguridad certificado: anteojos de seguridad ANSI Z87.1 (CAN/CSA Z94.3) con protección lateral al usar el compresor. Antes de arrancar el compresor, tire del anillo de la válvula de seguridad para asegurarse de que la válvula de seguridad trabaja libremente. NOTA: Es posible que resulte difícil jalar del anillo cuando la presión del tanque de aire sea 0 psi. Si la válvula está atascada o no opera con facilidad, se la debe reemplazar con el mismo tipo de válvula. Drenar el tanque de aire (Fig. 1) 1-800-433-9258 (1-800 4-DeWALT) ADVERTENCIA: Riesgo de operación insegura. Riesgo por ruidos. Los tanques de aire contienen aire de alta presión. Mantenga la cara y otras partes del cuerpo lejos de la salida del drenaje. Utilice anteojos de seguridad [ANSI Z87.1 (CAN/CSA Z94.3)], ya que al drenar se pueden desprender residuos hacia la cara. ADVERTENCIA: Riesgo de ruido excesivo. Utilice siempre protección auditiva apropiada al usar esta herramienta. Bajo algunas condiciones y duraciones de uso, el ruido producido por este producto puede contribuir a la pérdida auditiva. NOTA: Todos los sistemas de aire comprimido generan condensación que se acumula en cualquier punto de drenaje (por ejemplo, tanques, filtro, posenfriadores, secadores). Esta condensación contiene aceite lubricante y/o sustancias que pueden estar reguladas y que se deben desechar conforme a las leyes y reglamentaciones locales, estatales y federales. ADVERTENCIA: Riesgo de explosión. Drene el tanque de aire diariamente. El agua se condensará en el tanque de aire. Si no se drena, el agua corroerá y debilitará al tanque de aire provocando el riesgo de rotura del mismo. AVISO: Riesgo de daño a la propiedad. Drene el agua del tanque de aire puede contener aceite y óxido, lo que puede provocar manchas. 1. Asegúrese de que el mini interruptor (A) esté en la posición de apagado (OFF(0)). 2. Coloque un recipiente adecuado debajo de la válvula de drenaje (H) para recoger la descarga. 3. Tome el palanca estriado de la válvula de drenaje. 4. Gire lentamente el palanca para descargar aire del tanque de aire en forma gradual. 5. Cuando el manómetro del tanque de aire marque 10 psi, gire la válvula hasta la posición de completamente abierta. 6. Cierre la válvula de drenaje cuando termine. Controlar el elemento del filtro de aire (Fig. 1) ADVERTENCIA: Superficies calientes. Riesgo de superficies calientes. El tubo de enchufe, cabeza de la bomba, y las piezas circundantes son muy calientes, no toca. Permita que el compresor se refresque antes del mantenimiento. 1. Asegúrese de que el mini interruptor (A) esté en la posición de apagado (OFF(0)). 2. Permita que la unidad se frío. 3. Retire la cubierta del filtro (J) de base. 4. Retire el elemento de base del filtro. 5. Ponga el nuevo elemento detrás en base del filtro. Compre las piezas de recambio de su distribuidor local o centro de servicio autorizado. Utilice siempre las piezas de recambio idénticas. 6. Cubierta rápida del filtro para filtrar la base. AVISO: Riesgo de operación insegura. No opere la unidad sin el filtro de entrada de aire. Accesorios ADVERTENCIA: El uso de accesorios no recomendados para utilizar con esta herramienta puede resultar peligroso. Use solamente accesorios con una capacidad nominal igual o superior a la de la compresor de aire. Los accesorios que se recomiendan para la herramienta están disponibles para la compra en su distribuidor local o en el centro de mantenimiento autorizado. Si necesita ayuda para localizar algún accesorio para su herramienta, comuníquese con DeWALT Industrial Tool Co., 701 East Joppa Road, Towson, MD 21286, llame al 1-800-4-DeWALT (1-800-433-9258) o visite nuestro sitio Web www. dewalt. com. Información del servicio técnico Tenga a mano la siguiente información cuando llame al mantenimiento: Número del modelo ____________________ Número de serie ___________________ Fecha y lugar de compra ____________________________ Reparaciones Para asegurar la SEGURIDAD y la CONFIABILIDAD del producto, las reparaciones, el mantenimiento y los ajustes deben ser realizados por un centro de servicio de fábrica DeWALT, un centro de servicio autorizado DeWALT u otro personal de mantenimiento calificado. Utilice siempre piezas de repuesto idénticas. Póliza de Garantía IDENTIFICACIÓN DEL PRODUCTO: Sello o firma del Distribuidor. Nombre del producto: _____________ Mod./Cat.: _____________ Marca: __________ Núm. de serie:__________ (Datos para ser llenados por el distribuidor) Fecha de compra y/o entrega del producto: __________________ Nombre y domicilio del distribuidor donde se adquirió el producto: ______________________ __________________________________________________________________________________ Este producto está garantizado por un año a partir de la fecha de entrega, contra cualquier defecto en su funcionamiento, así como en materiales y mano de obra empleados para su fabricación. Nuestra garantía incluye la reparación o reposición del producto y/o componentes sin cargo alguno para el cliente, incluyendo mano de obra, así como los gastos de transportación razonablemente erogados derivados del cumplimiento de este certificado. Para hacer efectiva esta garantía deberá presentar su herramienta y esta póliza sellada por el establecimiento comercial donde se adquirió el producto, de no contar con ésta, bastará la factura de compra. EXCEPCIONES. Esta garantía no será válida en los siguientes casos: • Cuando el producto se hubiese utilizado en condiciones distintas a las normales; • Cuando el producto no hubiese sido operado de acuerdo con el instructivo de uso que se acompaña; • Cuando el producto hubiese sido alterado o reparado por personas distintas a las enlistadas al final de este certificado. Anexo encontrará una relación de sucursales de servicio de fábrica, centros de servicio autorizados y franquiciados en la República Mexicana, donde podrá hacer efectiva su garantía y adquirir partes, refacciones y accesorios originales. Garantía completa de un año SOLAMENTE PARA PROPÓSITO DE MÉXICO: IMPORTADO POR: DeWALT S.A. DE C.V. BOSQUES DE CIDROS, ACCESO RADIATAS NO.42 3A. SECCIÓN DE BOSQUES DE LAS LOMAS DELEGACIÓN CUAJIMALPA, 05120, MÉXICO, D.F. TEL. (52) 555-326-7100 R.F.C.: BDE810626-1W7 GLOSARIO CFM: Pies cúbicos por minuto. SCFM: Pies cúbicos estándar por minuto; unidad de medida de suministro de aire. PSI: Libras por pulgada cuadrada; una unidad de medida de presión. kPa (kilopascal): Medición métrica de la presión. 1 kilopascal es equivalente a 1000 pascales. Código de certificación: Los productos que usan una o más de las siguientes marcas: UL®, CUL, CULUS, ETL®, CETL, CETLUS, han sido evaluados por OSHA, laboratorios independientes certificados en seguridad, y reúnen los estándares suscriptos por a la certificación de la seguridad. *UL® es una marca registrada de Underwriters Laboratories y ETL® es una marca registrada de Electrical Testing Laboratories. Presión de arranque: Mientras el motor está apagado, la presión del tanque de aire cae cuando utiliza un accesorio. Cuando la presión del tanque baja a determinado nivel el motor volverá a encenderse automáticamente. La presión baja en la cual el motor se vuelve a encender automáticamente se llama presión de arranque. Presión de corte: Cuando se enciende o cuando comienza a funcionar un compresor de aire, comienza a elevarse la presión del aire en el tanque de aire. Se eleva hasta determinada presión antes de que el motor se apague automáticamente, protegiendo a su tanque de aire de una presión de aire mayor a su capacidad. La presión alta en la cual el motor se apaga se llama presión de corte. Circuito de derivación: Es el circuito que lleva electricidad del tablero eléctrico al tomacorriente. Factor de trabajo: Esta bomba del compresor de aire puede funcionar en forma continua. Sin embargo, para prolongar la vida útil del compresor de aire, se recomienda que se mantenga un promedio entre un 50% y un 75% de factor de trabajo, por lo que la bomba del compresor de aire no debe funcionar más de 30 a 45 minutos en una hora dada. Guía de detección de problemas Esta sección proporciona una lista de las fallas que se presentan con mayor frecuencia, sus causas y las medidas correctivas correspondientes. El operador o el personal de mantenimiento pueden llevar a cabo algunas de estas acciones correctivas, pero es posible que otras necesiten la asistencia de un técnico DeWALT calificado o de su distribuidor. Problema Código Presión excesiva en el tanque de aire: la válvula de seguridad salta ..........................1, 2 Pérdidas de aire ...................................................................................................................3 Pérdidas de aire en el tanque de aire o en las soldaduras del tanque de aire ...............4 Pérdidas de aire entre el cabezal y la placa de la válvula..................................................5 Pérdidas de aire de la válvula de seguridad.......................................................................6 Ruido de golpeteo................................................................................................................6 La lectura de la presión en el manómetro regulado cae cuando se usa un accesorio...7 El compresor no suministra suficiente aire para operar los accesorios......................................................................8, 9, 10, 11, 12, 22 La perilla del regulador tiene una pérdida constante de aire...........................................13 El regulador no cierra la salida de aire..............................................................................13 El motor no funciona...................................................... 6, 14, 15, 16, 17, 18, 19, 20 Sonidos agudos..................................................................................................................21 Códigos de detección de problemas CÓDIGO CAUSA POSIBLE 1 El interruptor de presión no apaga el motor cuando el compresor alcanza la presión de corte. 2 El valor de corte del interruptor de presión es demasiado alto 3 Las conexiones de los tubos no están bien ajustadas. 4 Tanque de aire defectuoso 5 Sellos de pérdidas 6 Válvula de seguridad defectuosa El regulador no está correctamente ajustado para el uso de un accesorio 7 8 9 10 Las herramientas industriales DeWALT para trabajo pesado tienen garantía de un año a partir de la fecha de compra. Repararemos, sin cargo, cualquier defecto debido a fallas en los materiales o la mano de obra. Para obtener información sobre las reparaciones cubiertas por la garantía, llame al 1‑800‑4‑DeWALT (1-800-433-9258). Esta garantía no se extiende a los accesorios o a los daños causados por terceros al intentar realizar reparaciones. Esta garantía le concede derechos legales específicos; usted goza también de otros derechos que varían según el estado o provincia. AMÉRICA LATINA: Esta garantía no se aplica a los productos que se venden en América Latina. Para los productos que se venden en América Latina, debe consultar la información de la garantía específica del país que viene en el empaque, llamar a la compañía local o visitar el sitio Web a fin de obtener esa información. REEMPLAZO GRATUITO DE LAS ETIQUETAS DE ADVERTENCIA (Fig. 4): Si sus etiquetas de advertencia se tornan ilegibles o faltan, llame al 1-800-4-DeWALT (1-800-4339258) para que se le reemplacen gratuitamente. 11 PARA REPARACIÓN Y SERVICIO DE SUS HERRAMIENTAS ELÉCTRICAS, FAVOR DE DIRIGIRSE AL CENTRO DE SERVICIO MÁS CERCANO 17 CULIACAN, SIN Blvd.Emiliano Zapata 5400-1 Poniente Col. San Rafael GUADALAJARA, JAL Av. La Paz #1779 - Col. Americana Sector Juárez MEXICO, D.F. Eje Central Lázaro Cárdenas No. 18 Local D, Col. Obrera 12 13 14 15 16 18 19 (667) 717 89 99 (33) 3825 6978 20 (55) 5588 9377 MERIDA, YUC Calle 63 #459-A - Col. Centro (999) 928 5038 MONTERREY, N.L. Av. Francisco I. Madero 831 Poniente - Col. Centro (818) 375 23 13 PUEBLA, PUE 17 Norte #205 - Col. Centro (222) 246 3714 QUERETARO, QRO Av. San Roque 274 - Col. San Gregorio (442) 2 17 63 14 SAN LUIS POTOSI, SLP Av. Universidad 1525 - Col. San Luis (444) 814 2383 TORREON, COAH Blvd. Independencia, 96 Pte. - Col. Centro (871) 716 5265 VERACRUZ, VER Prolongación Díaz Mirón #4280 - Col. Remes (229) 921 7016 VILLAHERMOSA, TAB Constitución 516-A - Col. Centro (993) 312 5111 Para servicio y ventas consulte “HERRAMIENTAS ELECTRICAS” en la sección amarilla. 21 22 Uso excesivo y prolongado de aire El compresor no es lo suficientemente grande para el accesorio Agujero en la manguera de aire Válvula de control restringida Pérdidas de aire El regulador está dañado SOLUCIÓN POSIBLE Ponga el mini interruptor en apagado (OFF(0)), si la unidad no se apaga comuníquese con un centro de servicio de fábrica DeWALT o con un centro de servicio autorizado DeWALT. Comuníquese con un centro de servicio de fábrica DeWALT o con un centro de servicio autorizado DeWALT. Ajuste las conexiones en los lugares donde sienta escapes de aire. Controle las conexiones con una solución de agua jabonosa. No ajuste demasiado. Se debe reemplazar el tanque de aire. No repare la pérdida. ADVERTENCIA: Riesgo de explosión. No perfore, suelde ni modifique el tanque de aire o el mismo se debilitará. El tanque de aire se puede romper o explotar. Comuníquese con un centro de servicio de fábrica DeWALT o con un centro de servicio autorizado DeWALT. Opere la válvula de seguridad manualmente tirando del anillo. Si la válvula aún pierde, debe ser reemplazada. Es normal que se presente alguna caída de presión cuando se usa un accesorio, ajuste el regulador como se indica en Regulador en la sección Características si la caída es excesiva. NOTA: Ajuste la presión regulada bajo condiciones de flujo mientras se usa el accesorio. Disminuya el uso de aire. Controle los requisitos de aire del accesorio. Si es mayor que el flujo de aire o la presión provista por su compresor de aire, necesita un compresor más grande para operar el accesorio. Reemplace la manguera de aire. Comuníquese con un centro de servicio de fábrica DeWALT o con un centro de servicio autorizado DeWALT. Ajuste las conexiones. Reemplácelo Se activó el interruptor de Consulte Sobrecarga del motor en la sección Características. sobrecarga del motor Si la protección de la sobrecarga del motor dispara con frecuencia, comuníquese con un centro de servicio de fábrica DeWALT o con un centro de servicio autorizado DeWALT. La presión del tanque El motor arrancará en forma automática cuando la presión del excede la presión de tanque descienda por debajo de la presión de arranque del arranque del interruptor interruptor de presión. de presión El cable prolongador Verifique el calibre del conductor y la longitud del cable es de longitud o calibre adecuados. Consulte Cables prolongadores en la incorrectos sección Instalación. Conexiones eléctricas Comuníquese con un centro de servicio de fábrica DeWALT o flojas con un centro de servicio autorizado DeWALT. Posible motor Comuníquese con un centro de servicio de fábrica DeWALT o defectuosos con un centro de servicio autorizado DeWALT. Piezas internas del motor Comuníquese con un centro de servicio de fábrica DeWALT salpicadas con pintura o con un centro de servicio autorizado DeWALT. No opere el compresor en la zona salpicada con pintura. Consulte la advertencia sobre vapor inflamable. Fusible quemado, 1. Controle si hay algún fusible quemado en la caja interruptor automático de fusibles y reemplácelo de ser necesario. Reinicie activado el interruptor automático. No utilice un fusible o un interruptor automático de valor mayor al especificado para su circuito de derivación en particular. 2. Verifique si el fusible es correcto. Utilice solamente un fusible de acción retardada. 3. Verifique si hay bajo voltaje y/o si el cable prolongador es el adecuado. 4. Desconecte los otros artefactos eléctricos del circuito u opere el compresor sobre su propio circuito de derivación. Correa desgastada Comuníquese con un centro de servicio de fábrica DeWALT o con un centro de servicio autorizado DeWALT. Filtro de entrada de aire Limpie o reemplace el filtro de entrada de aire. No haga restringida funcionar al compresor sin el filtro. Consulte el párrafo Filtro de aire en la sección Mantenimiento. PARA OTRAS LOCALIDADES: Si se encuentra en México, por favor llame al (55) 5326 7100 Si se encuentra en U.S., por favor llame al Specifications/ Fiche technique/ Especificaciones MODEL/ MODÈLE/ MODELO WEIGHT/ POIDS/ PESO HEIGHT/ HAUTEUR/ ALTURA WIDTH/ LARGEUR/ ANCHO LENGTH/ LONGUEUR/ LONGITUD AIR TANK CAPACITY/ CAPACITÉ DU RÉSERVOIR D’AIR/ CAPACIDAD DEL TANQUE DE AIRE APPROX CUT-IN PRESSURE/ PRESSION D’ENCLENCHEMENT APPROX./ PRESIÓN DE ARRANQUE APROXIMADA APPROX. CUT-OUT PRESSURE/ ENV. PRESSION DE DÉCLENCHEMENT/ PRESIÓN DE CORTE APROX. SCFM @ 90 PSI/ PI3/MIN STANDARD À 90 PSI/ SCFM A 90 PSI NOISE LEVEL/ NIVEAU SONORE/ NIVEL DE RUIDO VOLTAGE/ TENSION/ VOLTAJE MINIMUM BRANCH CIRCUIT REQUIREMENT/ EXIGENCE MINIMALE DU CIRCUIT DE DÉRIVATION/ REQUISITO MÍNIMO PARA EL CIRCUITO DE DERIVACIÓN: FUSE TYPE/ TYPE DE FUSIBLE/ FUSIBLE DE TIPO REGULATED PRESSURE RATING (APPROXIMATE) / PRESSION NOMINALE STABILISÉE (APPROXIMATIVE)/ CLASIFICACIÓN DE PRESIÓN REGULADA (APROXIMADAMENTE) QUICK CONNECT TYPE/ TYPE DE RACCORD À CONNEXION RAPIDE/ TIPO DE CONEXIÓN RÁPIDA D55168 105 lbs. (47.6 kg)/ 47,6 kg (105 lbs.)/ 47,6 kg (105 libras) 41.75" (1060.5 mm)/ 1060,5 mm (41,75 po)/ 1060,5 mm (41,75 ") 19,0" (482.6 mm)/ 482,6 mm (19,0 po)/ 482,6 mm (19,0 ") 21.25" (539.8 mm)/ 539,8 mm (21,25 po)/ 539,8 mm (21,25 ") 15 Gallon (56.8 liters)/ 56.8 liters (15 gallons)/ 56.8 L (15 galones) 180 psi/ 180 psi/ 180 psi 225 psi/ 225 psi/ 225 psi 5.0 */ 5,0 */ 5,0 * 78 dBA +/ 78,0 dBA +/ 78,0 dBA + Single 120V/ monophasé, 120V/ 120V, una sola fase 15 A/ 15 A/ 15 A Time delay/ temporisation/ acción retardada 3–150 psi/ 3–150 psi/ 3 a 150 psi 1/4" (6.4 mm) Industrial/ 6,4 mm (1/4 po.) Industriel/ 6,4 mm (1/4 ") Industrial *Tested per ISO 1217:1996/ Testé conformément à la norme ISO 1217:1996/Probado según la norma ISO 1217:1996 + Tested per ISO 3744:1994/ Testé conformément à la norme ISO 3744:1994/Probado según la norma ISO 3744:1994 Declared Noise Emission Values per ISO 3744 NOISE EMISSION VALUES Sound Pressure Level: LpA = 78.0 dBA re 20μPA Uncertainty in the Sound Pressure Level: KpA = 3.0 dBA re 20μPA Sound Power Level: LwA = 92.0 dBA re 1 pw Uncertainty in the Sound Power Level: KwA = 3.0 dBA re 1 pw The sum of the emission value and the uncertainty is the limit below which there is a 95% confidence the value of a single tool will lie below when the tool is new. Valeurs de l’émission de bruits déclarées en conformité avec l’ISO 3744 Valores de emisión de ruido declarados según ISO 3744 VALEUR DE L’ÉMISSION DE BRUITS Nivel de presión del sonido: LpA = 78,0 dBA re 20μPA Incertidumbre en el nivel de presión del sonido: KpA = 3,0 dBA re 20μPA Nivel de potencia del sonido: LwA = 92,0 dBA re 1 pw Incertidumbre en el nivel de potencia del sonido: KwA = 3,0 dBA re 1 pw La suma del valor de emisión y de la incertidumbre es el límite debajo del cual hay un porcentaje de confianza del 95% de que estará el valor de una herramienta cuando la herramienta es nueva. Niveau de pression acoustique : LpA = 78,0 dBA re 20μPA Incertitude du niveau de pression acoustique calculé : KpA = 3,0 dBA re 20μPA Niveau de puissance acoustique : LwA = 92,0 dBA re 1 pw Incertitude du niveau de puissance acoustique : KwA = 3,0 dBA re 1 pw La somme de la valeur de l’émission et de l’incertitude établit la limite sous laquelle la valeur pour un seul outil y sera inférieure et ce, à 95 % de fiabilité statistique. VÁLVULAS DE EMISIÓN DE RUIDO
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

DeWalt D55168 Manual de usuario

Categoría
Compresores de aire
Tipo
Manual de usuario

en otros idiomas