Yamaha V1 Manual de usuario

Tipo
Manual de usuario

Este manual también es adecuado para

This supplementary manual explains the functionality that was added or changed in TXn firm-
ware V1.3. Please read it together with the TX6n/TX5n/TX4n reference manual.
Partial Lock has been added as a Panel parameter value option on the Front Panel Operation page of the
UTILITY screen.
PIN Code has been added to the Front Panel Operation page of the UTILITY screen.
A shortcut has been added to access the library screen for Speaker Processor components.
Partial Lock has been added as a Panel parameter value
option on the Front Panel Operation page of the UTILITY
screen to limit access to certain functions.
Partial Lock: Only the following operations are available
from the amplifier’s front panel:
Using the [MUTE] button
Controlling attenuation
Recalling library settings for a Speaker Processor
component in the SIGNAL PATH screen.
A PIN Code setting (Personal Identification Number
Code) has been added to the Front Panel Operation page of
the UTILITY screen.
Set your PIN Code by entering a four-digit number, then
pressing the [ENTER] button.
Once you set your PIN Code, you will be prompted with
the PIN Code input screen if you try to temporarily release
the panel lock or initialize internal memory.
Assigning 0000 (default value) to the PIN Code will nul-
lify the code setting.
You can use a shortcut to recall the library screen for
Speaker Processor components.
From the HOME screen, press and hold down the [HOME]
and [ENTER] buttons simultaneously for more than one
second to recall the library screen.
TXn V1.3 Supplementary Manual
Main changes
Partial Lock added to
Front Panel Operation
PIN Code added to
Front Panel Operation
In Amp Editor, Partial Lock has also been added as an option for the
Panel parameter (accessed by selecting Utility
Setup
Front
Panel Operation
Panel).
Even if the MUTE key or Att. Dial setting is locked in Amp Editor, you
will still be able to use the [MUTE] button or adjust attenuation.
NO TE
Shortcut added to access
the library screen
for Speaker Processor components
• Initializing User Data in internal memory will initialize the PIN Code
and set it to 0000.
To temporarily disable panel lock, simultaneously hold down the
[HOME] button and [EXIT] button for three seconds or longer.
While holding down the [HOME] button, turn on the power; the Ini-
tialize screen will appear.
NO TE
EN
C.S.G, Pro Audio Division
© 2012 Yamaha Corporation
201PO-B0

Transcripción de documentos

TXn V1.3 Supplementary Manual This supplementary manual explains the functionality that was added or changed in TXn firmware V1.3. Please read it together with the TX6n/TX5n/TX4n reference manual. Main changes  Partial Lock has been added as a Panel parameter value option on the Front Panel Operation page of the UTILITY screen.  PIN Code has been added to the Front Panel Operation page of the UTILITY screen.  A shortcut has been added to access the library screen for Speaker Processor components. Partial Lock added to Front Panel Operation Partial Lock has been added as a Panel parameter value option on the Front Panel Operation page of the UTILITY screen to limit access to certain functions. Set your PIN Code by entering a four-digit number, then pressing the [ENTER] button. Once you set your PIN Code, you will be prompted with the PIN Code input screen if you try to temporarily release the panel lock or initialize internal memory. Partial Lock: Only the following operations are available from the amplifier’s front panel: • Using the [MUTE] button • Controlling attenuation • Recalling library settings for a Speaker Processor component in the SIGNAL PATH screen. Assigning 0000 (default value) to the PIN Code will nullify the code setting. NOTE NOTE • In Amp Editor, Partial Lock has also been added as an option for the Panel parameter (accessed by selecting Utility  Setup  Front Panel Operation  Panel). • Even if the MUTE key or Att. Dial setting is locked in Amp Editor, you will still be able to use the [MUTE] button or adjust attenuation. PIN Code added to Front Panel Operation A PIN Code setting (Personal Identification Number Code) has been added to the Front Panel Operation page of the UTILITY screen. • Initializing User Data in internal memory will initialize the PIN Code and set it to 0000. • To temporarily disable panel lock, simultaneously hold down the [HOME] button and [EXIT] button for three seconds or longer. • While holding down the [HOME] button, turn on the power; the Initialize screen will appear. Shortcut added to access the library screen for Speaker Processor components You can use a shortcut to recall the library screen for Speaker Processor components. From the HOME screen, press and hold down the [HOME] and [ENTER] buttons simultaneously for more than one second to recall the library screen. C.S.G, Pro Audio Division © 2012 Yamaha Corporation 201PO-B0 EN
  • Page 1 1

Yamaha V1 Manual de usuario

Tipo
Manual de usuario
Este manual también es adecuado para