DAS DASNET-RACK99-230 Manual de usuario

Tipo
Manual de usuario
DASNET-RACK99-230
User's Manual
Antes de utilizar el equipo, lea la sección
“Precauciones de seguridad” de este manual.
Conserve este manual para futuras consultas.
Before operating the device, please read the
“Safety precautions” section of this manual.
Retain this manual for future reference.
DASnet
CONTENTS
6 - 8
9 - 14
12 x AERO-40A + 8 UX-218A
12 x AERO-40A + 6 UX-221A
INTRODUCTION
ANNEX II : DASnet cables
3
4
5
17
15 - 16
ANNEX I : Schematics
CONFIGURATIONS
SAFETY PRECAUTIONS
WARRANTY
DECLARATION OF CONFORMITY
Manual del Usuario / DASNET-RACK99-230 / User’s Manual
3
DASNET-RACK 99-230
Precauciones de Seguridad
Safety Precautions
Caja de distribución para DASnet / DASnet Splitter
Equipo diseñado para funcionar entre 15ºC y 45ºC con una
humedad relativa máxima del 95%, con un rango de ±10% de la
tensión nominal de alimentación indicada en la etiqueta.
Working temperature ranges from 15ºC to 45ºC with a relative
humidity of 95%, with ±10% of the rated main voltage value
indicated on the label.
No instale el aparato cerca de ninguna fuente de calor como
radiadores, estufas u otros aparatos que produzcan calor. Debe
instalarse siempre sin bloquear la libre circulación de aire por las
aletas del radiador.
Do not install near any heat sources such as radiators, heat
registers, stoves or other apparatus that produce heat.
The circulation of air through the heatsink must not be blocked.
No exponga este equipo a la lluvia o humedad sin el protector
de lluvia recomendado. No exponga el equipo a salpicaduras sin
el protector de lluvia recomendado, ni coloque sobre él objetos
que contengan líquidos, tales como vasos y botellas.
Do not expose this device to rain or moisture without the rain
protector supplied. Do not place any objects containing liquids,
such as bottles or glasses, on the top of the unit. Do not splash
liquids on the unit without the rain protector supplied.
Este símbolo indica que el presente producto no puede ser
tratado como residuo doméstico normal, sino que debe
entregarse en el correspondiente punto de recogida de equipos
eléctricos y electrónicos.
This symbol on the product indicates that this product should
not be treated as household waste. Instead it shall be handed
over to the appicable collection point for the recycling of
electrical and electronic equipment.
El cableado exterior conectado al equipo requiere de su
instalación por una persona instruida o el uso de cables flexibles
ya preparados.
The outer wiring connected to the device requires installation by
an instructed person or the use of a flexible cable already
prepared.
Si el aparato es conectado permanentemente, la instalación
eléctrica del edificio debe incorporar un interruptor multipolar con
separación de contacto de al menos 3mm en cada polo.
If the apparatus is connected permanently, the electrical system
of the building must incorporate a multipolar switch with a
separation of contact of at least 3mm in each pole.
Limpie con un paño seco. No use limpiadores con disolventes. Clean only with a dry cloth. Do not use any solvent based
cleaners.
No existen partes ajustables por el usuario en el interior de este
equipo. Cualquier operación de mantenimiento o reparación
debe ser realizada por personal cualificado. Es necesario el
servicio técnico cuando el equipo se haya dañado de alguna
forma, como que haya caído líquido o algún objeto en el interior
del aparato, haya sido expuesto a lluvia o humedad, no funcione
correctamente, haya recibido un golpe o su cable de red esté
dañado.
No user serviceable parts inside. Refer all servicing to qualified
service personnel. Servicing is required when the apparatus has
been damaged in any way, such as power-supply cord or plug is
damaged, liquid has been spilled or objects have fallen into the
apparatus, the apparatus has been exposed to rain or moisture,
does not operate normally or has been dropped.
The exclamation point inside an equilateral triangle is intended to
alert the users to the presence of important operating and
maintenance (servicing) instructions in the literature
accompanying the product. Heed all warnings. Follow all
instructions. Keep these instructions.
WARNING: This is a class A product. In a domestic environment
this product may cause radio interferences in which case the
user may be required to take adequate measures.
Use this product only in E1, E2, E3 or E4 environments
according to EN55103-2.
No desconecte la tierra en el conector de alimentación pues es
peligroso e ilegal. Equipo de Clase I. El producto debe ser
conectado a un enchufe con toma de tierra. Sólo use este
equipo con el cable de red de alimentación adecuado para su
país.
El signo del rayo con la punta de flecha, alerta contra la
presencia de voltajes peligrosos no aislados. Para reducir el
riesgo de choque eléctrico, no retire la cubierta.
Do not remove mains connector ground, it is dangerous and
illegal. Class I device. The product must be connected to a
mains socket outlet with protective earth connection. Only use
this equipment with an appropriate mains cord for your country.
The lightning and arrowhead symbol warns about the presence
of uninsulated dangerous voltage. To reduce the risk of electric
shock, do not remove the cover.
El signo de exclamación dentro de un triángulo indica la
existencia de importantes instrucciones de operación y
mantenimiento en la documentación que acompaña al producto.
Conserve y lea todas estas instrucciones. Siga las advertencias.
ATENCIÓN: Es un producto clase A, por lo que en entornos
domésticos puede causar radio-interferencias, en cuyo caso el
usuario tendrá que tomar las medidas oportunas.
De acuerdo con EN55103-2, usar el equipo sólo en entornos E1,
E2, E3 ó E4.
Para desconectar el dispositivo debe usar el enchufe.
Desconecte este aparato durante tormentas eléctricas,
terremotos o cuando no se vaya a emplear durante largos
periodos.
To disconnect the device, you should use the mains plug. Unplug
this apparatus during lightning storms, earthquakes or when
unused for long periods of time.
Manual del Usuario / DASNET-RACK99-230 / User’s Manual
4
Manual del Usuario / DASNET-RACK99-230 / User’s Manual
GARANTÍA
WARRANTY
Todos nuestros productos están garantizados por un periodo de 24
meses desde la fecha de compra.
Las garantías sólo serán válidas si son por un defecto de
fabricación y en ningún caso por un uso incorrecto del producto.
Las reparaciones en garantía pueden ser realizadas,
exclusivamente, por el fabricante o el servicio de asistencia técnica
autorizado.
Otros cargos como portes y seguros, son a cargo del comprador
en todos los casos.
Para solicitar reparación en garantía es imprescindible que el
producto no haya sido previamente manipulado e incluir una
fotocopia de la factura de compra.
All our products are warrantied against any manufacturing defect
for a period of 2 years from date of purchase.
The warranty excludes damage from incorrect use of the product.
All warranty repairs must be exclusively undertaken by the factory
or any of its authorised service centers.
To claim a warranty repair, do not open or intend to repair the
product.
Return the damaged unit, at shippers risk and freight prepaid, to
the nearest service center with a copy of the purchase invoice.
5
Y es conforme a las siguientes Normas Armonizadas Europeas:
In accordance with Harmonized European Norms:
l EN 60065:2014.- Audio, video and similar electronic apparatus. Safety
requirements.
l EN 55032:2012.- Electromagnetic compatibility of multimedia equipment.
Emission requirements.
l EN 55103-2:2009.- Electromagnetic compatibility. Product family
standard for audio, video, audio-visual and entertainment lighting control
apparatus for professional use. Part 2:Immunity.
l EN 50581:2012.- Technical documentation for the assessment of
electrical and electronic products with respect to the restriction of
hazardous substances.
Cumple con los objetivos esenciales de las Directivas:
Abide by essential objectives relating Directives:
l de Baja Tensión (Low Voltage Directive) 2014/35/UE
l de Compatibilidad Electromagnética (EMC) 2014/30/UE
l RoHS 2011/65/UE
l RAEE (WEEE) 2012/19/UE
DECLARACIÓN DE CONFORMIDAD
DECLARATION OF CONFORMITY
DAS Audio Group, S.L.
C/ Islas Baleares, 24 - 46988 - Pol. Fuente del Jarro - Valencia. España
(Spain).
Declara que DASNET-RACK99-230:
Declares that DASNET-RACK99-230:
Manual del Usuario / DASNET-RACK99-230 / User’s Manual
INTRODUCTION
6
The DASNET-RACK99-230, assembled in a 19", 8U high rack, is composed of three elements:
1x DASNET-MATRIX99, 1x DASNET-PATCH-PW-9 and 1x DISTRO-RACKNET-32-9 (all described in the
following sections of this manual). Knowing the needs required by the system in terms of
distribution of power, currents and supply voltages and electrical safety guidelines, will be
essential for a safe use of this rack.
Caution: Before connecting to the mains make sure that all electrical safety specifications
and guidelines are met, and that all the safety warnings have been given due attention.
The DISTRO-RACKNET-32-9 allows the distribution of power between the different equipment
that form the system in a simple and safe way, and consists of:
DISTRO-RACKNET-32-9
I
FI40 30mA 4pol.
FI-Schalter
DASNET-MATRIX99
DASNET-RACK99-230
DASNET-PATCH-PW-9
1U high panel
8U high rack
DISTRO-RACKNET-32-9
I
FI40 30mA4pol.
FI-Schalter
A
D
B
C
Frontal View Rear View
E
A.- Three phase connector type IEC60309 or cetac, 32A / 400V for the input.
B.- Three phase connector type IEC60309 or cetac, 32A / 400V for the output (looped with the input).
C.- Phase 1, Phase 2 , Phase 3 breakers (one per ouput; total 9 units). The breakers are 16A nominal
current (In), type C (max Peak current > 5In).
D.- Phase LEDS. Indicate power per phase.
E.- Schuko outputs. There are 3 outputs per phase. There is one Auxiliary output connected in
parallel to the output 1 of phase 1 (max. 10W).
230/115 V~
1
OUT
2
OUT
3
OUT
PH.1 PH.2 PH.3
1
OUT
1
OUT
2
OUT
2
OUT
3
OUT
3
OUT
MAX.16A
per OUT
L3
L2
L1
N
PE
L2
L3
L1
N
AUDIO IN
AUDIO / DASNET OUT
LINK 1&2 LINK 2&3 LINK 3&4 LINK 4&5 LINK 5&6 LINK 6&7 LINK 7&8 LINK 8&9
TERMINATION
RESISTOR
Matrix 9X9
POWER
ON
ON
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
1
3
2
PE
Manual del Usuario / DASNET-RACK99-230 / User’s Manual
7
DASNET-PATCH-PW-9
DASNET-MATRIX99
The DASNET-PATCH-PW-9 provides AC power up to 9 connected devices, in a simple and
safe manner, using Neutrik connectors type PowerCon True1. The information on the AC
voltage range of the power supply and the maximum current available for each output is
shown on the silkscreen.
On the rear of DASNET-PATCH-PW-9, a total of 9 cables with schuko are located. Each one of
the cables with its corresponding schuko must be connected to each output of the DISTRO-
RACKNET-32-9. On the other hand, the Schuko Auxiliary output of this will serve to power the
DASNET-MATRIX99.
On the rear panel, using a power cable, the DASNET-MATRIX99 will be connected to the Schuko
Auxiliary output of the DISTRO-RACKNET-32-9. This cable has a Neutrik connector type PowerCon
True1 at one end and an F type (CEE 7/7) plug at the other. In addition, we have 9 balanced audio
outputs that are in parallel with the inputs.
The DASNET-MATRIX99 distribution module routes 9 balanced audio channels and DASnet
monitoring data up to 9 “zones” or clusters with self-powered DAS Audio systems.
On the front panel of DASNET-MATRIX99 we can view three connector types:
The first, AUDIO IN, female XLR type for 9 balanced audio inputs. The panel includes 8 link
switches for routing audio from inputs to outputs. By the use of the switches one unique audio
signal can be routed to all ethercon outputs (per example).
The second, AUDIO / DASNET OUT, Neutrik etherCon type to distribute audio and
monitoring data to the different groups of self powered cabinets, 9 DASnet output connectors.
Finally we have the RS-485 connectors, which allow us to join several matrix to form a
network with RS-485 protocol. Between the connectors the end-of-line switch is observed.
230/115 V~
1
OUT
2
OUT
3
OUT
PH.1 PH.2 PH.3
1
OUT
1
OUT
2
OUT
2
OUT
3
OUT
3
OUT
MAX.16A
per OUT
LED indicates Phase has power
Neutrik PowerCon True1 connector
Voltage range and max. current per output
Outputs connected to Phase 1: L1 Outputs connected to Phase 2: L2 Outputs connected to Phase 3: L3
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
AUDIO OUT
100-230V~ 50/60Hz
10W
AC INPUT
AUDIO IN
AUDIO / DASNET OUT
LINK 1&2 LINK 2&3 LINK 3&4 LINK 4&5 LINK 5&6 LINK 6&7 LINK 7&8 LINK 8&9
TERMINATION
RESISTOR
Matrix 9X9
POWER
ON
ON
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
1
3
2
Neutrik PowerCon True1 connector
AUDIO IN:
Female XLR type connectors
RS-485 OUT:
Male XLR type connector
LED ON
AUDIO OUT:
Male XLR type connectors
RS-485 IN:
Female XLR type connector
Link switch for the inputs of the matrix
Switch to active termination resistor
FRONT PANEL
REAR PANEL
AUDIO / DASNET OUT:
Neutrik EtherCon connectors
POWER
ON
Manual del Usuario / DASNET-RACK99-230 / User’s Manual
Internally, each DASNET-MATRIX99 has an RS-485 repeater that is directly connected after
the RS-485 input. The repeater allows having larger distances of cabling in the network and a
much higher number of devices without loosing capabilities.
The DASNET-MATRIX99 is an ideal solution for audio and monitoring data distribution in self
powered cabinets that include DASnet: AERO-20A, AERO-40A, UX-221A, UX-30A, UX-218A, UX-
218A-R, LX-218CA-NET, ROAD-12A-NET, ROAD-15A-NET, etc.
zone 1
zone 2
“Terminator resistor” activated
“Terminator resistor” activated
DASnet
USB-RS485
Example of typical
touring network
with standard RS-485
Example of input links
There is a termination resistor which can
be activated with a switch. It is
recommendable to engage it in the first and
last matrix of the network to increase
network stability.
With this system, ideal solution for
touring, we can link a maximum number of
144 devices, with a maximum total length
of the DASnet data cable should not
exceed 1000 meters (counting both XLR
data cables and ecp_xx CAT 7 cables).
The RS-485 protocol needs a USB to
RS-485 converter. This converter is
provided by DAS Audio with every system
pruchased. The USB to RS-485 converter
has to be connected to the DASNET-
MATRIX99 using the IN RS-485 connector.
On the other hand, the DASNET-MATRIX99 offers flexible routing with switches on the front
panel that allow you to mount an audio input to several outputs. The nine audio inputs can be
linked directly to their corresponding ethercon outputs. In addition, a single audio input can be
linked to all ethercon outputs by using the switches.
That is, if you look at the figure below, we have linked the inputs 1 with 2 on one side and 2
with 3 on the other. With this, it is enough to enter audio through connector 1 to output that
signal through all the connected output connectors: 1, 2 and 3, both ethercon on the front,
and XLR on the rear.
With this system, we can send a signal to all the equipment (linking all the outputs with the
input 1) or create several zones with different signal sends.
AUDIO IN
AUDIO / DASNET OUT
LINK 1&2 LINK 2&3 LINK 3&4 LINK 4&5 LINK 5&6 LINK 6&7 LINK 7&8 LINK 8&9
TERMINATION
RESISTOR
Matrix 9X9
POWER
ON
ON
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
1
3
2
AUDIO I N
AUDIO / DA SNE T OUT
LINK 1&2 LINK 2&3 LINK 3&4 LINK 4&5 LINK 5&6 LINK 6&7 LINK 7&8 LINK 8&9
TERMINATION
RESISTOR
Matrix 9X9
POWER
ON
ON
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
1
3
2
AUDIO I N
AUDIO / DA SNE T OUT
LINK 1&2 LINK 2&3 LINK 3&4 LINK 4&5 LINK 5&6 LINK 6&7 LINK 7&8 LINK 8&9
TERMINATION
RESISTOR
Matrix 9X9
POWER
ON
ON
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
1
3
2
AUDIO IN
AUDIO / DASNET OUT
LINK 1&2 LINK 2&3 LINK 3&4 LINK 4&5 LINK 5&6 LINK 6&7 LINK 7&8 LINK 8&9
TERMINATION
RESISTOR
Matrix 9X9
POWER
ON
ON
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
2
3
1
PUSH
1
3
2
POWER
ON
8
Manual del Usuario / DASNET-RACK99-230 / User’s Manual
As we have indicated the DASNET-RACK99-230 allows a power distribution of up to 32Amp
per phase (three-phase). Every 3 outputs of the DISTRO-RACKNET-32-9 of power are connected
to a single phase. This means that of each group of 3 PowerCon True 1 connectors, the
maximum available current is 32A.
The user must always consider the power consumption of the equipment (specified at 1/3
of the nominal power with pink noise) connected to each output and DO NOT exceed the limit
of 32A for each group of 3 PowerCon outputs.
9
CONFIGURATIONS
L R
2 x eCPK_20
2 x eCPK_20 2 x eCPK_20
2 x eCPK_20
2 x eCPk_1
2 x eCPk_1
DASNET-RACK99-230
MAX.
20A/ OUT
1
OUT
2
OUT
3
OUT
PH.1 PH.2 PH.3
1
OUT
1
OUT
2
OUT
2
OUT
3
OUT
3
OUT
AUDIO IN
AUDIO / DASNET OUT
LINK 1&2 LINK 2&3 LINK 3&4 LINK 4&5 LINK 5&6 LINK 6&7 LINK 7&8 LINK 8&9
Matrix 9X9
POWER
ON
ON
I
FI4030mA4pol.
FI-Schalter
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
2
3
1
PUSH
1
3
2
MAX.
20A/ OUT
1
OUT
2
OUT
3
OUT
PH.1 PH.2 PH.3
1
OUT
1
OUT
2
OUT
2
OUT
3
OUT
3
OUT
AUDIO IN
AUDIO / DASNET OUT
LINK 1&2 LINK 2&3 LINK 3&4 LINK 4&5 LINK 5&6 LINK 6&7 LINK 7&8 LINK 8&9
Matrix 9X9
POWER
ON
ON
I
FI40 30mA4pol.
FI-Schalter
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
2
3
1
PUSH
1
3
2
FROM 3 x AERO-40A L
FROM 3 x AERO-40A L
FROM 3 x AERO-40A R
FROM 3 x AERO-40A R
FROM 2 x UX-218A L
FROM 2 x UX-218A L
FROM 2 x UX-218A R
FROM 2 x UX-218A R
This is the recommended power distribution of the example configuration:
Example 1 : 12 x AERO-40A + 8 x UX-218A
Load per Phase:
Phase 1 = 3 x 3A + 3 x 3A + 3 x 3A = 27A
Phase 2 = 3 x 3A + 2 x 4,5A + 2 x 4,5A = 27A
Phase 3 = 2 x 4,5A + 2 x 4,5A = 18A
Manual del Usuario / DASNET-RACK99-230 / User’s Manual
With the system configurations, DAS Audio recommends the maximum number of
cabinets that can be connected depending on the model, the power consumption
and the total equipment used (see table below).
No te: C on su mption measured at 1/3 of nominal power with p in k no is e.
(1 ) M od el s: ROAD-12ART-NET230, ROAD-12ALT-NET230, ROAD-12ART-NET115, ROAD-12ALT-NET115
(2) Models: ROAD-15ART-NET230, ROAD-15ALT-NET230, ROAD-15ART-NET115, ROAD-15ALT-NET115
Label of DASNET-RACK99-230
Consumption
per unit
Mains
1,8A
230V
3,6A
115V
3A 6A
4,5A 9A
9A 18A
6,7A 13,4A
3A 6A
3,1A
1,7A
1,7A
6,2A
3,4A
3,4A
10
Manual del Usuario / DASNET-RACK99-230 / User’s Manual
AERO-20A
AERO-40A
UX-218A
UX-221A
UX-30A
LX-118A
LX-218CA-NET
(1)
ROAD-12A-NET
(2)
ROAD-15A-NET
S/N
3/N/PE
400/230 V
50Hz/60Hz
Rated Current: 32A
Rated Voltage:
IP rating: IP20
www.dasaudio.com
DAS Audio Group, S.L. (Valencia) MADE IN SPAIN
MODEL: DASNET-RACK99-230
11
eCPK_20 (CAT 7 ethernet cable + 3x2.5mm2, audio +data + power, 20m length)
eC_09 (CAT 7 ethernet cable; audio +data, 90cm length)
Plink1_09 (power link 2.5mm2 90cm)
Speaker cabling
Rigging frames
A40 Accessories
x 8
x 3
x 4
x 2
x 4
x 8
x 8
x 1
AX-AE40S3
Covers
FUN-4-AE40 is a protective nylon cover for 4 AERO-40A
FUN-2-UX218 nylon cover for a stack of 2 UX-218A
Dollies
PL-UX218S
The PL-UX218S dolly is used to
transport stacks of 2 or 3 UX-218A.
DSP-4080
Dollies
Processors (included in the racks)
x 1
x 3
PL-40S metal transport dolly for 3 or 4 AERO-40A
eCPk_1 (ethernet cable)
x 4
228cm / 90”
228cm / 90”
243cm / 96”
243cm / 96”
251cm / 99”
251cm / 99”
American Truck 90” x 232” American Truck 90” x 232”
Euro truck Euro truck
American Truck 99” x 232” American Truck 99” x 232”
4 x aero40 4 x aero40
4 x aero40
4 x aero40 4 x aero40
4 x aero40
4 x aero40 4 x aero40
4 x aero40
4 x aero40
4 x aero40 4 x aero40
4 x aero40
4 x aero40 4 x aero40
4 x aero40
4 x aero40
4 x aero40
UX-218A
UX-218A
UX-218A
UX-218A
UX-218A
UX-218A
UX-218A
UX-218A
UX-218A
UX-218A
UX-218A
UX-218A
12 AERO-40A + 8 UX-218A 12 AERO-40A
USB-RS485 Converter
x 1
AUDIO IN
AUDIO / DASNET OUT
LINK 1&2 LINK 2&3 LINK 3&4 LINK 4&5 LINK 5&6 LINK 6&7 LINK 7&8 LINK 8&9
TERMINATION
RESISTOR
Matrix 9X9
POWER
ON
ON
I
FI40 30mA 4pol.
FI-Schalter
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
2
3
1
PUSH
1
3
2
MAX.
16A/ OUT
1
OUT
2
OUT
3
OUT
PH.1 PH.2 PH.3
1
OUT
1
OUT
2
OUT
2
OUT
3
OUT
3
OUT
DASNET-RACK99
Manual del Usuario / DASNET-RACK99-230 / User’s Manual
Example 2 : 12 x AERO-40A + 6 x UX-221A
12
3 x eCPK_20
2 x eCPK_20
LINKLINKLINKLINK
LINK LINK LINK LINK
LINK LINK LINK LINK
LINKLINKLINKLINK
L R
DSP-4080
EDIT
2 x eCPK_20
3 x eCPK_20
DASNET-RACK-99
AUDIO IN
AUDIO / DASNET OUT
LINK 1&2 LINK 2&3 LINK 3&4 LINK 4&5 LINK 5&6 LINK 6&7 LINK 7&8 LINK 8&9
TERMINATION
RESISTOR
Matrix 9X9
POWER
ON
ON
I
FI4030mA 4pol.
FI-Schalter
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
2
3
1
PUSH
1
3
2
USB-R S485 converter
DASNET-RACK-99
AUDIO IN
AUDIO / DASNET OUT
LINK 1&2 LINK 2&3 LINK 3&4 LINK 4&5 LINK 5&6 LINK 6&7 LINK 7&8 LINK 8&9
TERMINATION
RESISTOR
Matrix 9X9
POWER
ON
ON
I
FI4030mA 4pol.
FI-Schalter
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
2
3
1
PUSH
1
3
2
MAX.
16A/ OUT
1
OUT
2
OUT
3
OUT
PH.1 PH.2 PH.3
1
OUT
1
OUT
2
OUT
2
OUT
3
OUT
3
OUT
MAX.
16A/ OUT
1
OUT
2
OUT
3
OUT
PH.1 PH.2 PH.3
1
OUT
1
OUT
2
OUT
2
OUT
3
OUT
3
OUT
Manual del Usuario / DASNET-RACK99-230 / User’s Manual
13
MAX.
16A/ OUT
1
OUT
2
OUT
3
OUT
PH.1 PH.2 PH.3
1
OUT
1
OUT
2
OUT
2
OUT
3
OUT
3
OUT
MAX.
16A/ OUT
1
OUT
2
OUT
3
OUT
PH.1 PH.2 PH.3
1
OUT
1
OUT
2
OUT
2
OUT
3
OUT
3
OUT
DASNET-RACK-99
AUDIO IN
AUDIO / DASNET OUT
LINK 1&2 LINK 2&3 LINK 3&4 LINK 4&5 LINK 5&6 LINK 6&7 LINK 7&8 LINK 8&9
TERMINATION
RESISTOR
Matrix 9X9
POWER
ON
ON
I
FI40 30mA 4pol.
FI-Schalter
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
2
3
1
PUSH
1
3
2
DASNET-RACK-99
AUDIO I N
AUDIO / DA SNET O UT
LINK 1&2 LINK 2&3 LINK 3&4 LINK 4&5 LINK 5&6 LINK 6&7 LINK 7&8 LINK 8&9
TERMINATION
RESISTOR
Matrix 9X9
POWER
ON
ON
I
FI40 30mA 4pol.
FI-Schalter
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
2
3
1
PUSH
1
3
2
FROM 3 x AERO-40A L FROM 3 x AERO-40A R
FROM 3 x AERO-40A L FROM 3 x AERO-40A R
FROM 1 x UX-221A L
FROM 1 x UX-221A L
LOAD PER PHASE
PHASE 1: 18A
PHASE 2: 18A
PHASE 3: 9A
LOAD PER PHASE
PHASE 1: 18A
PHASE 2: 18A
PHASE 3: 9A
FROM 1 x UX-221A L
FROM 1 x UX-221A R
FROM 1 x UX-221A R
FROM 1 x UX-221A R
Manual del Usuario / DASNET-RACK99-230 / User’s Manual
14
DSP-4080
eCPK_20 (CAT 7 ethernet cable + 3x2.5mm2, audio +data + power, 20m length)
eC_09 (CAT 7 ethernet cable; audio +data, 90cm length)
Plink1_09 (power link 2.5mm2 90cm)
Speaker cabling Dollies
Processors (included in the racks)
DASNET-RACK99
Rigging frames
A40 Accessories
x 10
x 3
x 2
x 2
x 2
x 1
x 3
x 8
x 8
x 2
AX-AE40S3
PL-40S metal transport dolly for 3 or 4 AERO-40A
Covers
FUN-4-AE40 is a protective nylon cover for 4 AERO-40A
FUN-3-UX221 nylon cover for a stack of 3 UX-221A
Dollies
PL-221S
The PL-221S dolly is used to
transport stacks of 2 or 3 UX-221A.
12 AERO-40A + 6 UX-221A
12 AERO-40A
243cm / 96”
228cm / 90”251cm / 99”
228cm / 90”
4 x aero404 x aero40
4 x aero40
243cm / 96”
251cm / 99”
4 x aero40
4 x aero40
4 x aero40
4 x aero40
4 x aero40
Euro Truck 6m Trailer
American Truck 90” x 232”
American Truck 99” x 232”
4 x aero40
4 x aero40
4 x aero40
4 x aero40
4 x aero40
4 x aero40
4 x aero40 4 x aero40
4 x aero40
4 x aero40
3 x UX-221A3 x UX-221A
3 x UX-221A
3 x UX-221A
3 x UX-221A3 x UX-221A
USB-RS485 Converter
x 1
AUDIO IN
AUDIO / DASNET OUT
LINK 1&2 LINK 2&3 LINK 3&4 LINK 4&5 LINK 5&6 LINK 6&7 LINK 7&8 LINK 8&9
TERMINATION
RESISTOR
Matrix 9X9
POWER
ON
ON
I
FI40 30mA 4pol.
FI-Schalter
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
2
3
1
PUSH
1
3
2
MAX.
16A/ OUT
1
OUT
2
OUT
3
OUT
PH.1 PH.2 PH.3
1
OUT
1
OUT
2
OUT
2
OUT
3
OUT
3
OUT
Manual del Usuario / DASNET-RACK99-230 / User’s Manual
15
ANNEX I : Schematics
_ _
____
_ _ _
_ _ _
_
_ _ _
_ _
_
_
_
_
_
_
_ _
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
PC 230V 16A
L1 L3L2
N L2L1 L3 N L2L1 L3
40A/30mA
RCD
PC 230V 16A PC 230V 16A PC 230V 16A PC 230V 16A PC 230V 16A PC 230V 16A PC 230V 16A PC 230V 16APC 230V 16A
PH3.1 PH3.2 PH3.3PH2.3PH2.2PH2.1PH1.3PH1.2PH1.1AUX
OUT (Looped)IN
DISTRO-RACKNET-32-9
Manual del Usuario / DASNET-RACK99-230 / User’s Manual
16
1.0
Manual del Usuario / DASNET-RACK99-230 / User’s Manual
17
ANNEX II : DASnet cables
1 Orange-White Audio+ 2
2 Orange Audio- 3
3 Green-White Audio Earth 1
4 Blue
5 Blue-White
6 Green Data Earth 1
7 Brown-White Data- (A) 3
8 Brown Data+ (B) 2
etherCon XLR
It is very important to use the system with the intended cables to prevent electromagnetic
interferences between the analog audio signal, the DASnet data and the power. Be sure to
check the specifications provided by the cable manufacturer. It is also especially important
when installing connectors yourself, to note that when termination is not accurate, a cable
will be unable to achieve its maximum performance and could have interferences.
There are 4 different types of cables.
- The main feeds which include power and a STP, CAT7 cable. These cables are named
eCP_xx (xx refers to cable length).
- Power Links between cabinets.Cable code Plink1_09
- Links for RoadNet series. Power+STP CAT7. eCPk_1/eCPk_5
- The links between cabinets (aero40A/Convert15A/LX-218CAnet), which are STP CAT7
cables. Cable code eC_09
The main feed cable eCP_xx has the following structure:
AL Shield
2 2
ecP_xx: Power cable 3x2.5mm + CAT7 4x (2 x 0.14mm )
Jacket
Jacket
STP CAT 7 cable with Aluminium
Shield for each individual pair
and a main aluminium Shield.
The main Shield has to be
soldered to the etherCon
housing.
The eC_09 cable is a CAT5e
cable with global Aluminium
Shield.
Important
The pin out of the EtherCon to XLR is the following on the eCP cables:
Manual del Usuario / DASNET-RACK99-230 / User’s Manual
UM_RACK99_03_EN
www.dasaudio.com
DAS Audio of America, INC.
6900 NW 52th Street
Miami, FL. 33166 - U.S.A.
TOLL FREE: 1 888 DAS 4 USA
DAS Audio Asia PTE. LTD.
3 Temasek Avenue, Centennial
Tower #34-36
Singapore 039190
Tel. +65 6549 7760
DAS Audio Group, S.L.
C/. Islas Baleares, 24
46988 Fuente del Jarro
Valencia, SPAIN
Tel. +34 96 134 0860
DAS do Brasil LTDA.
Rua Dos Andradas, 382 SL
Santa Efigênia, São Paulo
Brasil. CEP: 01208-000
Tel. +551133330764
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18

DAS DASNET-RACK99-230 Manual de usuario

Tipo
Manual de usuario

en otros idiomas