1) TURN OFF POWER.
IMPORTANT: Before you start, NEVER attempt any work without
shutting off the electricity until the work is done.
a) Go to the main fuse, or circuit breaker, box in your home. Place
the main power switch in the “OFF” position.
b) Unscrew the fuse(s), or switch “OFF” the circuit breaker switch(s),
thatcontrolthepowertothextureorroomthatyouareworking
on.
c) Placethewallswitchinthe“OFF”position.Ifthexturetobe
replaced has a switch or pull chain, place those in the “OFF” position.
2) Thread hexnut onto threaded pipe so that approximately 5 threads are
exposed above hexnut. Thread that end of threaded pipe into mounting
strap. Thread second hexnut onto end of threaded pipe protruding from
back of mounting strap. Tighten both hexnuts against mounting strap
3) Attach mounting strap to outlet box. (Screws not provided)
4) Grounding instructions: (See Illus. A or B).
A) Onxtureswheremountingstrapisprovidedwithaholeand
two raise dimples. Wrap ground wire from outlet box around
green ground screw, and thread into hole.
B) Onxtureswhereacuppedwasherisprovided.Attachground
wire from outlet box under cupped washer and green ground
screw, and thread into mounting strap.
Ifxtureisprovidedwithgroundwire.Connectxturegroundwireto
outlet box ground wire with wire connector. (Not provided.) After following
the above steps.
Never connect ground wire to black or white power supply wires.
5) Make wire connections (connectors not provided.) Reference chart
below for correct connections and wire accordingly.
6) Pushxturetowall,carefullypassingthreadedpipethroughhole.
7) Securexturetowallusingthreadedcap.
8) Insert recommended bulb.
9) Lowerglassdownoversocket.Fitbottomofglassinsidecuponxture
base.Carefullyturnglasstosecureglassinplace.(DONOTovertighten.)
10)Setroofdownontopofxture.
11) Threadscrewsdownthroughholesinroofandintoxture.Tighten
screws to secure roof in place.
INSTRUCTIONS FOR MOUNTING FIXTURE OUTDOORS AND/OR
IN WET LOCATIONS.
12)Mountingsurfaceshouldbeclean,dry,atand1/4”largerthatthe
canopy on all sides. Any gaps between the mounting surface and
canopyexceeding3/16”shouldbecorrectedasrequired.
13) With silicone caulking compound, caulk completely around where back
of canopy meets the wall surface to prevent water from seeping into
outlet box.
1) APAGUELAALIMENTACIÓNELÉCTRICA.
IMPORTANTE: Antesdecomenzar,NUNCAtratedetrabajarsinantes
desconectarlacorrientehastaqueeltrabajosetermine.
a) Vayaalacajaprincipaldefusibles,ointerruptorocajadecircuitos
desucasa.Coloqueelinterruptordelacorrienteprincipalen
posición de apagado “OFF”.
b) Desatornilleel(los)fusible(s),ocoloqueelinterruptoro
interruptoresdelbreakerenposicióndeapagado“OFF”,que
controla (n) la corriente hacia el artefacto o habitación donde está
trabajando.
c) Coloqueelinterruptordeparedenposicióndeapagado“OFF”.Si
elartefactoquesevaareemplazartieneuninterruptorocadena
quesejala,colóquelosenlaposicióndeapagado“OFF”.
2) Rosquelatuercahexagonaleneltuboroscadodemodoque
aproximadamente 5 roscas estén expuestas arriba de la tuerca hexagonal.
Rosqueeseextremodeltuboroscadoenlaabrazaderademontaje.
Rosqueunasegundatuercahexagonalenelextremodeltuboroscado
quesobresaledeatrásdelaabrazaderademontaje.Aprieteambas
tuercashexagonalescontralaabrazaderademontaje.
3) Sujetelaplanchaparamontaralacajadeconexión.(Noseproveen
los tornillos.)
4) Instrucciones de conexión a tierra solamente para los Estados Unidos.
(Vea la ilustracion A o B).
A) Enlaslámparasquetieneneleje,demontajeconunagujero
ydoshoyuelosrealzados.Enrollarelalambreatierradelacaja
tomacorrientealrededordeltornilloverdeypasarloporelaquiero.
B) Enlaslámparasconunaarandelaacopada.Fijarelalambrea
tierradelacajatomacorrientedelajodelaarandelaacoaday
tornilloverde,ypaserporelejedemontaje.
GREEN GROUND
SCREW
CUPPED
WASHER
A
B
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
(NOT PROVIDED)
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth) *Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire
DateIssued:3/23/12 IS-49475-US
THREADEDCAP
TAPAROSCADA
Silalámparavieneconalambreatierra.Conecterelalambreatierra
delalámparaalalambreatierradelacajatomacorrienteconunconector
de alambres. (No incluido) Espués de seguir los pasos anteriores.
Nunca conectar el alambra a tierra a los alambres eléctros negro o
blanco.
5) Haga les conexiones de los alambres (no se proveen los connectores.)
Latabladereferenciadeabajoindicalasconexionescorrectasylos
alambres correspondientes.
6) Empujeelartefactoalaparedpasandocuidadosamenteeltubo
roscadoatravésdelagujero.
7) Sujetelaunidadcontralaparedapretándolaconlataparoscada.
8) Inserte la bombilla recomendada.
9) Bajelapantallasobreelportalámparas.Encajelaparteinferiorde
la pantalla dentro de la taza en la base del artefacto. Gire la pantalla
con cuidado para asegurarla en el lugar. (NO apriete de más).
10) Asiente el techo en la parte superior del artefacto.
11) Rosquelostornillosatravésdelosagujeroseneltechoyenelarfefacto.
Aprietelostornillosparajarlatechoenelartefacto.
INSTRUCCIONES PARA EL MONTAJE DEL ARTEFACTO AL AIRE
LIBRE Y/O EN UN LUGAR MOJADO.
12)Lasuperciedemontajedebeestarlimpia,seca,serplanay1/4”más
grandequeelesdudeteentodoslosbordes.Cualquierespaciolibre
entrelasuperciedemontajeyelescudetequeexcedade3/16”debe
corregirsesegúnserequiera.
13)Calafateetotalmenteconcompuestodecalafateardesiliconaalrededor
dondeelescudetesientaenlasuperciedelaparedparaimpedirla
entradadeaguaenlacajadeconexiones.
Conectar el alambre de
suministro negro o rojo al
Conectar el alambre de
suministro blanco al
Negro Blanco
*Cordon paralelo (redondo y liso)
*Cordon paralelo (cuadrado y estriado)
Claro, marrón, amarillio o negro
sin hebra identificadora
Claro, marrón, amarillio o negro
con hebra identificadora
Alambre aislado (diferente del verde)
con conductor de cobre
Alambre aislado (diferente del
verde) con conductor de plata
*Nota: Cuando se utiliza alambre paralelo
(SPT I y SPT II). El alambre neutro es de forma
cuadrada o estriada y el otro alambre será de
forma redonda o lisa. (Vea la ilustracíón).
Hilo Neutral
THREADEDPIPE
TUBOROSCADO
MOUNTING STRAP
PLANCHAPARAMONTAR
ARANDELA
CONCAVA
A
B
TIERRA DE LA
CAJA DE SALIDA
TORNILLO DE TIERRA,
VERDE
DEPRESIONES
TIERRA
ARTEFACTO
CONECTOR DE ALAMBRE
(NO SE PROVEE)
TIERRA DE LA
CAJA DE SALIDA
TORNILLO DE TIERRA,
VERDE
TIERRA
ARTEFACTO
HEXNUT
TUERCA
HEXAGONAL
SCREW
TORNILLO
GLASS
VIDRIO
ROOF
TECHO

Transcripción de documentos

1) TURN OFF POWER. IMPORTANT: Before you start, NEVER attempt any work without shutting off the electricity until the work is done. a) Go to the main fuse, or circuit breaker, box in your home. Place the main power switch in the “OFF” position. b) Unscrew the fuse(s), or switch “OFF” the circuit breaker switch(s), that control the power to the fixture or room that you are working on. c) Place the wall switch in the “OFF” position. If the fixture to be replaced has a switch or pull chain, place those in the “OFF” position. 2) Thread hexnut onto threaded pipe so that approximately 5 threads are exposed above hexnut. Thread that end of threaded pipe into mounting strap. Thread second hexnut onto end of threaded pipe protruding from back of mounting strap. Tighten both hexnuts against mounting strap 3) Attach mounting strap to outlet box. (Screws not provided) 4) Grounding instructions: (See Illus. A or B). A) On fixtures where mounting strap is provided with a hole and two raise dimples. Wrap ground wire from outlet box around green ground screw, and thread into hole. B) On fixtures where a cupped washer is provided. Attach ground wire from outlet box under cupped washer and green ground screw, and thread into mounting strap. If fixture is provided with ground wire. Connect fixture ground wire to outlet box ground wire with wire connector. (Not provided.) After following the above steps. Never connect ground wire to black or white power supply wires. A SCREW TORNILLO ROOF TECHO GLASS VIDRIO B WIRE CONNECTOR (NOT PROVIDED) OUTLET BOX GROUND THREADED PIPE TUBO ROSCADO FIXTURE GROUND FIXTURE GROUND DIMPLES GREEN GROUND SCREW MOUNTING STRAP PLANCHA PARA MONTAR OUTLET BOX GROUND GREEN GROUND SCREW CUPPED WASHER HEXNUT TUERCA HEXAGONAL 5) Make wire connections (connectors not provided.) Reference chart below for correct connections and wire accordingly. Connect Black or Red Supply Wire to: 6) 7) 8) 9) Black White *Parallel cord (round & smooth) *Parallel cord (square & ridged) Clear, Brown, Gold or Black without tracer Clear, Brown, Gold or Black with tracer Insulated wire (other than green) with copper conductor Insulated wire (other than green) with silver conductor *Note: When parallel wires (SPT I & SPT II) are used. The neutral wire is square shaped or ridged and the other wire will be round in shape or smooth (see illus.) Neutral Wire Push fixture to wall, carefully passing threaded pipe through hole. Secure fixture to wall using threaded cap. Insert recommended bulb. Lower glass down over socket. Fit bottom of glass inside cup on fixture base. Carefully turn glass to secure glass in place. (DO NOT over tighten.) 10) Set roof down on top of fixture. 11) Thread screws down through holes in roof and into fixture. Tighten screws to secure roof in place. INSTRUCTIONS FOR MOUNTING FIXTURE OUTDOORS AND/OR IN WET LOCATIONS. 12) Mounting surface should be clean, dry, flat and 1/4” larger that the canopy on all sides. Any gaps between the mounting surface and canopy exceeding 3/16” should be corrected as required. 13) With silicone caulking compound, caulk completely around where back of canopy meets the wall surface to prevent water from seeping into outlet box. 1) APAGUE LA ALIMENTACIÓN ELÉCTRICA. IMPORTANTE: Antes de comenzar, NUNCA trate de trabajar sin antes desconectar la corriente hasta que el trabajo se termine. a) Vaya a la caja principal de fusibles, o interruptor o caja de circuitos de su casa. Coloque el interruptor de la corriente principal en posición de apagado “OFF”. b) Desatornille el (los) fusible (s), o coloque el interruptor o interruptores del breaker en posición de apagado “OFF”, que controla (n) la corriente hacia el artefacto o habitación donde está trabajando. c) Coloque el interruptor de pared en posición de apagado “OFF”. Si el artefacto que se va a reemplazar tiene un interruptor o cadena que se jala, colóquelos en la posición de apagado “OFF”. 2) Rosque la tuerca hexagonal en el tubo roscado de modo que aproximadamente 5 roscas estén expuestas arriba de la tuerca hexagonal. Rosque ese extremo del tubo roscado en la abrazadera de montaje. Rosque una segunda tuerca hexagonal en el extremo del tubo roscado que sobresale de atrás de la abrazadera de montaje. Apriete ambas tuercas hexagonales contra la abrazadera de montaje. 3) Sujete la plancha para montar a la caja de conexión. (No se proveen los tornillos.) 4) Instrucciones de conexión a tierra solamente para los Estados Unidos. (Vea la ilustracion A o B). A) En las lámparas que tienen el fleje, de montaje con un agujero y dos hoyuelos realzados. Enrollar el alambre a tierra de la caja tomacorriente alrededor del tornillo verde y pasarlo por el aquiero. B) En las lámparas con una arandela acopada. Fijar el alambre a tierra de la caja tomacorriente del ajo de la arandela acoada y tornillo verde, y paser por el fleje de montaje. Date Issued: 3/23/12 THREADED CAP TAPA ROSCADA Connect White Supply Wire to: Si la lámpara viene con alambre a tierra. Conecter el alambre a tierra de la lámpara al alambre a tierra de la caja tomacorriente con un conector de alambres. (No incluido) Espués de seguir los pasos anteriores. Nunca conectar el alambra a tierra a los alambres eléctros negro o blanco. A B CONECTOR DE ALAMBRE (NO SE PROVEE) TIERRA DE LA CAJA DE SALIDA TIERRA ARTEFACTO TIERRA ARTEFACTO TORNILLO DE TIERRA, VERDE DEPRESIONES TIERRA DE LA CAJA DE SALIDA TORNILLO DE TIERRA, VERDE ARANDELA CONCAVA 5) Haga les conexiones de los alambres (no se proveen los connectores.) La tabla de referencia de abajo indica las conexiones correctas y los alambres correspondientes. Conectar el alambre de suministro negro o rojo al Conectar el alambre de suministro blanco al Negro Blanco *Cordon paralelo (redondo y liso) *Cordon paralelo (cuadrado y estriado) Claro, marrón, amarillio o negro sin hebra identificadora Claro, marrón, amarillio o negro con hebra identificadora Alambre aislado (diferente del verde) con conductor de cobre Alambre aislado (diferente del verde) con conductor de plata *Nota: Cuando se utiliza alambre paralelo (SPT I y SPT II). El alambre neutro es de forma cuadrada o estriada y el otro alambre será de forma redonda o lisa. (Vea la ilustracíón). Hilo Neutral 6) Empuje el artefacto a la pared pasando cuidadosamente el tubo roscado a través del agujero. 7) Sujete la unidad contra la pared apretándola con la tapa roscada. 8) Inserte la bombilla recomendada. 9) Baje la pantalla sobre el portalámparas. Encaje la parte inferior de la pantalla dentro de la taza en la base del artefacto. Gire la pantalla con cuidado para asegurarla en el lugar. (NO apriete de más). 10) Asiente el techo en la parte superior del artefacto. 11) Rosque los tornillos a través de los agujeros en el techo y en el arfefacto. Apriete los tornillos para fijar la techo en el artefacto. INSTRUCCIONES PARA EL MONTAJE DEL ARTEFACTO AL AIRE LIBRE Y/O EN UN LUGAR MOJADO. 12) La superficie de montaje debe estar limpia, seca, ser plana y 1/4” más grande que el esdudete en todos los bordes. Cualquier espacio libre entre la superficie de montaje y el escudete que exceda de 3/16” debe corregirse según se requiera. 13) Calafatee totalmente con compuesto de calafatear de silicona alrededor donde el escudete sienta en la superficie de la pared para impedir la entrada de agua en la caja de conexiones. IS-49475-US
  • Page 1 1

Kichler Lighting 49475RZ Manual de usuario

Tipo
Manual de usuario

en otros idiomas