Hunter Fan 81003 Manual de usuario

Tipo
Manual de usuario
I n s t a l l a t i o n G u i d e
81003 Ashbury Bath Ventilator with Light
READ and SAVE THESE INSTRUCTIONS
41939-01 1/11/2006
2
DISCONNECT
ELECTRIC
POWER SUPPLY
AND LOCK OUT
SERVICE PANEL
BEFORE
SERVICING UNIT
W a r n i n g
TO REDUCE THE RISK OF ELECTRIC SHOCK OR INJURY, OBSERVE THE FOLLOWING:
1. For general ventilating use only. Do not use for ventilat-
ing hazardous or explosive materials.
2. To avoid motor bearing damage and noisy/unbalanced
impellers, keep drywall spray, construction dust, etc.
off power unit.
3. DO NOT install this product in a wall. This product is
designed for installation in ceilings up to a 12/12 pitch
(45 degrees). Ductwork must point upward.
4. Please read specification label on product for further
information and requirements.
PREVENTATIVE MAINTENANCE
A clean fan provides better service. Disconnect the power supply and clean the fan as listed below.
TO CLEAN GRILLE: Use a mild detergent, such as dishwashing liquid, and a soft cloth. DO NOT use abrasive cloths, steel
wool pads or scouring powders.
TO CLEAN FAN ASSEMBLY: Unplug motor cord from receptacle. To remove motor plate, find the single tab on the motor
plate (located next to the receptacle). Push up rear motor plate tab while pushing out on the side of the housing or insert a
screwdriver into the slot in the housing (next to tab) and twist screwdriver. Gently vacuum fan, motor and interior of housing.
METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER.
MAINTENANCE
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual
noises, replace the motor with the exact service motor. You should replace the impeller at the same time.
C a U T i O n
W a r n i n g
1. Use this unit only in a manner intended by the manufacturer.
If you have questions, contact the manufacturer at the phone
number or address listed in the warranty.
2. Before installing, servicing, or cleaning the unit,
disconnect the power by turning off the circuit breakers to
the outlet box and associated wall switch location. If you
cannot lock the circuit breakers in the off position, securely
attach a prominent warning device, such as a tag, to the
service panel.
3. Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhaust-
ing of gasses through the flue (chimney) of fuel burning
equipment to prevent backdrafting. Follow the heating
equipment manufacturer’s guideline and safety standards,
such as those published by the National Fire Prevention
Association (NFPA), and the American Society for Heating,
Refrigeration and Air-Conditioning Engineers (ASHRAE), and
the local code authorities.
5. When cutting or drilling into wall(s) or ceiling, do not
damage electrical wiring or other hidden utilities.
6. Ducted fans must always be vented to the outdoors. Keep
ducting as short and as straight as possible.
7. Acceptable for use over a bathtub or shower when
connected to a GFCI protected branch circuit.
8. Install fan at least 5 feet (1.52 m) above the floor.
9. Never place a switch where it can be reached from a tub
or shower.
10. This unit must be grounded.
11. For supply connection, use wires suitable for at least
90º C (194º F).
41939-01 1/11/2006
x2
E
F
G
H
I
J
K
L
95029-01-000
75191-01-000
03242-07-133
95491-02-000
74508-03-133
96397-01-444
75184-01-133
85812-03-000
M
75733-01-444
x4
3/8" Cable Connector
*
*
*
NOTE:
Strain relief cable connector
must be installed. Not Included.
A
B
C
Extra Screws
x2
I
3
1
Turn off the power source.
Tools Needed. (Not supplied.)
Estimated assembly time: 30 to 60 minutes
Before Installation
Check all the parts.
If damaged, call
1-888-830-1326
for replacements.
Included.
2
E
I
Loosen screws.
NOTE: Remove all packing materials before installation.
41939-01 1/11/2006
5
4
7
G
8
F
Remove the motor/blower from the housing.
4
H
E
3
Remove the pre-loaded screw tip covers.
Remove the wiring cover screw.
6
Back out the pre-loaded screw tips until flush
with the side of the housing.
Remove the wiring cover.
Remove packing material.
41939-01 1/11/2006
9
E
Pop out the first wiring access slug. Use second if needed. Insert the strain relief (not included) into the housing and
secure with washer.
Position the correct depth mark at the bottom edge of the
joist based on the thickness of your sheetrock.
New Construction
5
10
B
C
A11
E
5/8
1/2
5/8
1/2
A12
Screw pre-loaded screws into joist or framing.
Choose Installation Option
For New Construction - go to step A11, page 5
For Existing Construction - go to step B11, page 8
41939-01 1/11/2006
A
3 Pin
2 Pin
Fan Motor
Light
Light
Green
Black
Black
White
Black
Black
White
White
Bare Copper
Ground
A14
Main Switch 1 (AC In)
Switch 2 (AC In)
*Option Fan & Main Light Together
*Option
Connect wires as shown.
A13
Route wires through the strain relief. For supply connection,
use wires suitable for at least 90º C (194º F).
0
A16
Connect 4” duct and vent to the outside. Tape joints.
If ducting does not fit securely, an adapter may need
to be purchased.
6
A15
E
F
G
Install the wiring cover plate. Make sure all
wiring connections are inside the box or under
the wiring cover plate.
41939-01 1/11/2006
A19
I
A20
Reinstall the motor by inserting the tabs and pushing up
into position. Make sure the wires are not pinched
between the motor and the housing.
Secure the motor by tightening the 2 screws.
Turn on the power source.
7
Connect wiring harness. DO NOT ALLOW THE MOTOR TO
HANG FROM THE WIRING HARNESS.
0000
A17
0000
H
A18
ON
OF
F
A21
Test the motor. If the motor does not run, check the plug
connection.
A22
C1
Go to step
on page 10
to attach grille.
41939-01 1/11/2006
EXISTING FAN
B11
E
B12
8
Existing Construction
B13
2
1
B14
Route wires through the strain relief. For supply connection,
use wires suitable for at least 90º C (194º F).
Remove an existing fan and check to make sure the open-
ing is large enough to accommodate the new motor hous-
ing (7 1/4”x 7 3/4”).
Move the housing into position above the ceiling.
Attach existing ducting to duct connector. Tape joints.
If ducting does not fit securely,
an adapter may need to be purchased.
E
B15
Install the housing flush with the sheetrock and secure by
tightening the pre-loaded screws into the joist.
41939-01 1/11/2006
9
H
B18
H
B19
B20
I
Reinstall the motor by inserting the tabs and pushing up
into position. Make sure the wires are not pinched between
the motor and the housing.
Connect wiring harness. DO NOT ALLOW THE MOTOR TO
HANG FROM THE WIRING HARNESS.
Secure the motor by tightening the 2 screws.
A
3 Pin
2 Pin
Fan Motor
Light
Light
Green
Black
Black
White
Black
Black
White
White
Bare Copper
Ground
B16
Main Switch 1 (AC In)
Switch 2 (AC In)
*Option Fan & Main Light Together
*Option
Connect wires as shown.
F
B17
G
Install the wiring cover plate.
41939-01 1/11/2006
10
ON
OF
F
B22
B23
C1
Go to step
on page 10
to attach grille.
B21
Test the motor. If the motor does not run, check the plug
connection.
Turn on the power source.
J
M
C2
L
K
C1
Attaching the Grille
Remove the thumbscrews. Remove glass dome.
41939-01 1/11/2006
11
C4
J
J
K
C5
C6
C7
L
M
C8
Align posts 1, 2, and 3 (stamped into motor housing) with
posts 1, 2, and 3 (stamped into light fixture). Slide light
fixture over posts.
Attach thumbscrews.
WARNING: To reduce the risk of electrical shock,
all 4 thumbscrews MUST be properly installed.
Align glass dome and push up.
Install 2 Max 60 Watt A15 bulbs (Not Included).
Screw glass dome into position.
J
C3
Connect wiring harness. DO NOT ALLOW THE FIXTURE TO
HANG FROM THE WIRING HARNESS.
41939-01 1/11/2006
12
Trouble Shooting
Problem: Fan does not come on.
Solution:
Hunter Fan Bath Ventilators are extremely quiet. To confirm that the fan is running, place your hand near the vents to
feel the air movement.
Turn power on, replace fuse, or reset breaker.
• Check all plug connections to be sure they are secure.
• Check the wiring to make sure it matches the wiring diagram.
Problem: Light does not come on.
Solution:
Replace the light bulb with a new bulb.
Turn power on, replace fuse, or reset breaker.
Check all plug connections to be sure they are secure.
Check the wiring to make sure it matches the wiring diagram.
Problem: Fan is noisy.
Solution:
Check and tighten all fasteners.
Check the glass to make sure it is secure.
Check the flapper to make sure it moves freely.
If you need parts or service assistance, please call 888-830-1326 or visit us at our WEB site at http://www.hunterfan.com.
41939-01 1/11/2006
13
Warranty
Hunter Fan Company
Bath Exhaust Fan
LIMITED WARRANTY
Hunter Fan Company makes the following limited warranty to the original user or consumer purchaser of this Hunter bath
exhaust fan:
If any part of your Hunter bath exhaust fan (except for glass fixtures and light bulbs) fails at any time within one year after the date
of sale to you due to a defect in material or workmanship, we will repair or, at our option, replace the defective part free of charge
for parts and labor performed at our nearest service center or at our Service Department in Memphis, Tennessee. After this one-year
period, you will be responsible for all parts and labor costs for repairs on the bath exhaust fan except for motor repairs as
provided below.
If your Hunter bath exhaust fan motor fails at any time within five years after the date of sale to you due to a defect in material or
workmanship, labor and materials to repair the defect will be provided free of charge at our nearest service center or our Service
Department in Memphis, Tennessee. If no replacement part can be provided, we will, at our option, either refund the actual purchase
price of your bath exhaust fan or provide a replacement free of charge. After this five-year period, you will be responsible for all parts
and labor costs for repairs on all parts of the bath exhaust fan.
IF THE ORIGINAL USER OR CONSUMER PURCHASER CEASES TO OWN THE FAN, THIS WARRANTY AND ANY IMPLIED WARRANTY WHICH
THEN REMAINS IN EFFECT, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE, ARE VOIDED. NO WARRANTY, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE, IS MADE IN RESPECT OF GLASS FIXTURES OR LIGHT BULBS OR THE FINISH ON ANY METAL
PORTION OF THE BATH EXHAUST FAN.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES. THE DURATION OF ANY IMPLIED WARRANTY, INCLUDING, BUT NOT
LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, IN RESPECT TO ANY HUNTER
FAN BATH EXHAUST FAN MOTOR OR OTHER FAN PART, IS EXPRESSLY LIMITED TO THE PERIOD OF THE EXPRESS WARRANTY SET FORTH
ABOVE FOR SUCH MOTORS OR OTHER PARTS.
This warranty is voided if your Hunter bath exhaust fan is not purchased and installed in the U.S.A. This warranty excludes and does
not cover defects, malfunctions or failures of any Hunter bath exhaust fan which were caused by repairs by persons not authorized by
us, use of parts or accessories not authorized by us, mishandling, improper installation, modifications or damage to the Hunter bath
exhaust fan while in your possession, or unreasonable use, including failure to provide reasonable and necessary maintenance.
To obtain servicing, contact the nearest Hunter authorized service center of the Hunter Fan Company Service Department, 2500
Frisco Avenue, Memphis, Tennessee 38114. Please contact us before shipping your bath exhaust fan to us. If we authorize you to
ship it to us, you will be responsible for all insurance and freight or other transportation charges to our factory or service center. We
will return your Hunter bath exhaust fan freight prepaid. Your Hunter bath exhaust fan should be properly packed to avoid damage in
transit since we will not be responsible for any such damage. Proof of purchase is required when requesting warranty service. The
purchaser must present the sales receipt or other document that establishes proof of purchase.
IN NO EVENT SHALL HUNTER FAN COMPANY BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES.
SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION OR LIMITATION OF
INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSIONS MAY NOT APPLY TO YOU.
THE WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE
.
41939-01 1/11/2006
2500 Frisco Avenue, Memphis, Tennessee 38114
Printed in China
41939-01 1/11/2006
DESDE
G u í a d e i n s t a l a c i ó n
Ventilador para baño 81003 Ashbury con luz
LEA y CONSERVE ESTAS INSTRUCCIONES
41939-02 1/11/2006
2
DESCONECTE LA
ALIMENTACIÓN
ELÉCTRICA Y
CIERRE EL PANEL
DE SERVICIO
ANTES DE DAR
MANTENIMIENTO
A LA UNIDAD
tc.Retire las cubiertas de las puntas de tornillo precargadas.
A D V E R T E N C I A
PARA REDUCIR EL RIESGO DE DESCARGA ELÉCTRICA O LESIONES, OBSERVE LO SIGUIENTE:
1. Sólo para uso de ventilación general. No lo utilice para
ventilar ambientes con materiales peligrosos o explosivos.
2. Para evitar daños a los rodamientos del motor e impulsores
ruidosos o desbalanceados, mantenga la unidad de
potencia lejos de la aplicación de aerosol para paneles
de yeso (drywall), polvo de la construcción, etc.
3. NO instale este producto en una pared. Este producto
está diseñado para instalarse en techos con una
inclinación de hasta 12/12 (45º). La red de ductos debe
dirigirse hacia arriba.
4. Vea más información y los requisitos en la etiqueta de
especificación del producto.
MANTENIMIENTO PREVENTIVO
Un ventilador limpio proporciona mejor servicio. Desconecte la alimentación y limpie el ventilador como se indica a continuación.
PARA LIMPIAR LA REJILLA: Use un detergente suave, como líquido para lavado de platos, y un paño suave. NO emplee paños
abrasivos, almohadillas de lana de acero ni polvos para fregar.
PARA LIMPIAR EL CONJUNTO DEL VENTILADOR:
Desconecte el cordón del motor de la toma de corriente. Para retirar la placa del motor, encuentre la pestaña en la placa
(ubicada junto a la toma de corriente). Levante la pestaña posterior de la placa del motor mientras empuja hacia afuera en
el lado del alojamiento o introduzca un destornillador en la ranura del alojamiento (junto a la pestaña) y gire el destornillador.
Suavemente aspire el ventilador, el motor y el interior del alojamiento.
LAS PARTES METÁLICAS ELÉCTRICAS NUNCA DEBEN SUMERGIRSE EN AGUA.
MANTENIMIENTO
El motor está lubricado permanentemente y no necesita ser engrasado. Si los rodamientos del motor hacen ruidos excesivos
o inusuales, reemplace el motor con el motor de servicio exacto. Debe reemplazar el impulsor al mismo tiempo.
PRECAUCIÓN
ADVERTENCIA
1. Utilice esta unidad sólo de la manera indicada por el fabricante.
Si tiene alguna pregunta, contacte con el fabricante en el
teléfono o la dirección indicados en la garantía.
2. Antes de instalar, dar servicio o limpiar la unidad, desco-
necte la alimentación eléctrica apagando los interruptores
automáticos que alimentan la caja de salida y al interruptor
de pared respectivo. Si no puede bloquear los interruptores
automáticos en la posición de apagado, fije firmemente una
forma destacada de advertencia, como una etiqueta de
seguridad, en el tablero de servicio.
3. Los trabajos de instalación y cableado eléctrico deben ser
realizados por personas calificadas de acuerdo con todos los
códigos y las normas aplicables, incluyendo los códigos y
normas de construcción contra incendio.
4. Se necesita aire suficiente para una combustión adecuada y
para evacuar los gases por el tubo de la chimenea de equipo
que quema combustible a fin de evitar el flujo inverso. Siga
las pautas del fabricante del equipo de calefacción y las
normas de seguridad, como las de la Asociación Nacional de
Protección contra Incendios (NFPA), la Asociación de Ingenieros
Americanos en Calefacción y Aire acondicionado (ASHRAE), y
los códigos locales.
5. Al cortar o taladrar en paredes o techo, no dañe el cableado
eléctrico u otros servicios no visibles.
6. Los ventiladores canalizados siempre deben descargar al aire
libre. Mantenga los ductos tan cortos y rectos como sea posible.
7. Aceptable para uso sobre una bañera o ducha si se conecta
en un circuito derivado protegido por un interruptor
automático de falla a tierra (GFCI).
8. Instale el ventilador por lo menos a 5 pies (1.52 m) por
encima del piso.
9. Nunca coloque un interruptor donde pueda ser alcanzado
desde una tina o una ducha.
10. Esta unidad debe ponerse a tierra.
11.
Para conexiones de alimentación, use alambres adecuados al
menos para 90º C (194º F).
41939-02 1/11/2006
x2
E
F
G
H
I
J
K
L
95029-01-000
75191-01-000
03242-07-133
95491-02-000
74508-03-133
96397-01-444
75184-01-133
85812-03-000
M
75733-01-444
x4
*
*
A
B
C
x2
I
Conector de cable de 3/8”
*
Nota:
Nota: Debe estar instalado el
manguito de alivio de tensión del
cable. No incluido.
Tornillos adicionales
3
1
2
E
I
Apague la fuente de alimentación.
Incluido
Herramientas necesarias (no suministradas)
Tiempo estimado de ensamblaje: entre 30 y 60 minutos
Antes de la instalación
Verifique todos los
componentes. Si están dañados,
llame al 1-888-830-1326
para un reemplazo.
Afloje los tornillos.
NOTA: Retire todo el material de embalaje antes de la instalación.
41939-02 1/11/2006
5
4
7
G
8
F
4
H
E
3
6
Retire el motor/soplador del alojamiento.
Retire las cubiertas de las puntas de tornillo precargadas.
Retire el tornillo de la cubierta del cableado.
Retire las puntas de tornillo precargadas hasta que estén a
nivel con el lado del alojamiento.
Retire la cubierta del cableado.
Retire el material de embalaje.
41939-02 1/11/2006
9
E
5
10
B
C
A11
E
5/8
1/2
5/8
1/2
A12
Inserte el alivio de tensión (no se incluye) en la caja y sujé-
telo firmemente con una arandela.
Ubique la correcta marca de profundidad en el borde infe-
rior de la viga, según el espesor de su plancha de yeso.
Construcción nueva
Escoja la opción de instalación
Para construcción nueva -vaya al paso A11, página 5
Para construcción existente - vaya al paso B11, página 8
Instale los tornillos precargados en la viga o el marco.
Expulse el primer tapón metálico de acceso del cableado.
Utilice el segundo si es necesario.
41939-02 1/11/2006
A
Motor del ventilador
Luz
Verde
Interruptor negro 2 (AC)
Interruptor negro principal 1 (AC)
Blanco
Negro Luz
Blanco
Blanco
Cobre desnudo
Tierra
A14
*Opción Ventilador y luz principal juntos
*Opción
Negro
3
pasadores
3
pasadores
2
pasadores
2
pasadores
A13
0
A16
6
A15
E
F
G
Tienda los cables a través del alivio de tension. Para
conexiones de alimentación, use alambres adecuados al
menos para 90º C (194º F).
Conecte los alambres como se muestra.
Conecte un ducto de 4” y ventile hacia el exterior. Aplique
cinta a las uniones. Si el ducto no se ajusta firmemente,
puede ser necesario comprar un adaptado.
Instale la placa de cubierta del cableado. Asegúrese que
todas las conexiones de cableado estén dentro de la caja o
debajo de la placa de cubierta del cableado.
41939-02 1/11/2006
A19
I
A20
7
0000
A17
0000
H
A18
ENCENDIDO
AP
A
GADO
A21
A22
C1
Vaya al paso
en la página 10 para
fijar la rejilla.
Asegure el motor apretando los 2 tornillos.
Encienda la fuente de alimentación.
Conecte el mazo de cables. NO PERMITA QUE EL MOTOR
CUELGUE DEL MAZO DE CABLES.
Vuelva a instalar el motor introduciendo las pestañas y
levantando a su posición. Asegúrese que los alambres no
se pellizquen entre el motor y el alojamiento.
Pruebe el motor. Si el motor no funciona, verifique la
conexión del enchufe.
41939-02 1/11/2006
VENTILADOR EXISTENTE
B11
E
B12
8
Construcción existente
B13
2
1
B14
E
B15
Tienda los cables a través del alivio de tension. Para
conexiones de alimentación, use alambres adecuados al
menos para 90º C (194º F).
Retire el ventilador existente y asegúrese que la abertura
sea suficientemente grande para acomodar el alojamiento
del motor nuevo (7 1/4” x 7 3/4”).
Mueva el alojamiento a su posición encima del techo.
Conecte el ducto existente con el conector de ducto.
Aplique cinta a las uniones. Si el ducto no se ajusta firme-
mente, puede ser necesario comprar un adaptador.
Instale el alojamiento a nivel con la plancha de yeso y
asegúrelo apretando los tornillos precargados en la vida.
41939-02 1/11/2006
9
H
B18
H
B19
B20
I
A
Motor del ventilador
Luz
Verde
Interruptor negro 2 (AC)
Interruptor negro principal 1 (AC)
Blanco
Negro Luz
Blanco
Blanco
Cobre desnudo
Tierra
B16
*Opción Ventilador y luz principal juntos
*Opción
Negro
3
pasadores
3
pasadores
2
pasadores
2
pasadores
F
B17
G
Conecte los alambres como se muestra.
Vuelva a instalar el motor introduciendo las pestañas y
levantando a su posición. Asegúrese que los alambres no se
pellizquen entre el motor y el alojamiento.
Conecte el mazo de cables. NO PERMITA QUE EL MOTOR
CUELGUE DEL MAZO DE CABLES.
Asegure el motor apretando los 2 tornillos.
Instale la placa de cubierta del cableado.
41939-02 1/11/2006
10
ON
OF
F
B22
B23
C1
Go to step
on page 10
to attach grille.
B21
J
M
C2
L
K
C1
Fijación de la rejilla
Pruebe el motor. Si el motor no funciona, verifique la conex-
ión del enchufe.
Encienda la fuente de alimentación.
Retire los tornillos de mano. Retire le dome de verre.
41939-02 1/11/2006
11
C4
J
J
K
C5
C6
C7
L
M
C8
Alinee los postes 1, 2 y 3 (estampados en la caja del mo-
tor) con los postes 1, 2 y 3 (estampados en el artefacto de
ilumunación). Deslice la lámpara sobre los postes.
Instale los tornillos de mano. ADVERTENCIA: Para reducir el
riesgo de descarga eléctrica, los 4 tornillos de mano DEBEN
instalarse apropiadamente.
Alinee el domo de vidrio y levante.
Instale 2 bombillas A-15 de 60 vatios como máximo.
(No incluidas)
Enrosque el dome vidrio en su posición.
J
C3
Conecte el mazo de cables. NO PERMITA QUE EL MOTOR
CUELGUE DEL MAZO DE CABLES.
41939-02 1/11/2006
12
Solución de problemas
Problema: El ventilador no está operando.
Solución:
Los ventiladores de baño Hunter son muy silenciosos. Para confirmar que el ventilador esté funcionando, coloque su
mano cerca de los conductos de ventilación para sentir el movimiento del aire.
• Encienda la alimentación eléctrica, reemplace el fusible o restablezca el interruptor automático.
Verifique todas las conexiones de los enchufes para asegurarse que estén firmes.
Verifique el cableado para asegurarse que coincida con el diagrama de cableado.
Problema: La luz no funciona.
Solución:
Reemplace la bombilla con una nueva.
• Encienda la alimentación eléctrica, reemplace el fusible o restablezca el interruptor automático.
Verifique todas las conexiones de los enchufes para asegurarse que estén firmes.
Verifique el cableado para asegurarse que coincida con el diagrama de cableado.
Problema: El ventilador hace ruido.
Solución:
Verifique y apriete todos los pernos y tornillos.
Verifique la pantalla para asegurarse que esté firme.
Verifique la válvula de retención para asegurarse que se mueva con libertad.
Si necesita repuestos o servicio, llame al 888-830-1326 o visite nuestro sitio web en http://www.hunterfan.com.
41939-02 1/11/2006
13
Garantía
Hunter Fan Company
Extractor de aire para baño
GARANTÍA LIMITADA
Hunter Fan Company establece la siguiente garantía limitada al usuario o comprador original de este Extractor de aire para baño Hunter:
Si alguna pieza de su Extractor de aire para baño Hunter (con excepción de las lámparas de vidrio y las bombillas) falla en cualquier
momento dentro de un año después de la fecha de compra debido a una falla de material o mano de obra, repararemos o, a nuestra
elección, reemplazaremos la pieza defectuosa sin costo de partes y mano de obra realizada en nuestro centro de reparaciones más
cercano o en nuestro Departamento de servicio en Memphis, Tennessee. Después de este período de un año, usted será responsable
de todos los costos de partes y mano de obra para reparaciones del Extractor de aire para baño, con excepción de reparaciones del
motor, como se estipula a continuación.
Si el motor de su Extractor de aire para baño Hunter falla en cualquier momento dentro de cinco años después de la fecha de compra
debido a una falla de material o mano de obra, la mano de obra y los materiales para reparar la falla serán proporcionados sin costo
en nuestro centro de reparaciones más cercano o en nuestro Departamento de servicio en Memphis, Tennessee. Si no puede pro-
porcionarse alguna parte de reemplazo, a nuestra elección, le reembolsaremos el precio de compra real de su Extractor de aire para
baño o le proporcionamos uno de reemplazo sin costo. Después de este período de cinco años, usted será responsable de todos los
costos de partes y mano de obra para reparaciones de cualquier componente del Extractor de aire para baño.
SI EL USUARIO O COMPRADOR ORIGINAL DEJA DE POSEER EL EXTRACTOR DE AIRE, ESTA GARANTÍA Y CUALQUIER GARANTÍA
IMPLÍCITA QUE PERMANEZCA EN EFECTO, INCLUYENDO PERO SIN LIMITARSE A TODA GARANTÍA IMPLÍCITA DE COMERCIABILIDAD O
IDONEIDAD PARA UN PROPÓSITO PARTICULAR, QUEDA ANULADA. NO SE OFRECE NINGUNA GARANTÍA EXPRESA O IMPLÍCITA, INCLUY-
ENDO CUALQUIER GARANTÍA DE COMERCIABILIDAD O IDONEIDAD PARA UN PROPÓSITO PARTICULAR, PARA LAS LÁMPARAS DE VIDRIO
O LAS BOMBILLAS O EL ACABADO EN CUALQUIER PARTE METÁLICA DEL EXTRACTOR DE AIRE PARA BAÑO.
ESTA GARANTÍA SUSTITUYE A TODAS LAS OTRAS GARANAS EXPRESAS. LA DURACIÓN DE TODA GARANTÍA IMPLÍCITA, INCLUYENDO PERO SIN
LIMITARSE A CUALQUIER GARANTÍA IMPLÍCITA DE COMERCIABILIDAD O IDONEIDAD PARA UN PROPÓSITO PARTICULAR, CON RESPECTO DE
CUALQUIER MOTOR DE EXTRACTOR DE AIRE PARA BAÑO HUNTER U OTRA PARTE DEL VENTILADOR, ESTÁ EXPRESAMENTE LIMITADA AL
PERIODO DE LA GARANTIA EXPRESA ESTABLECIDA ANTERIORMENTE PARA DICHOS MOTORES U OTRAS PARTES.
Esta garantía es nula si su Extractor de aire para baño no se adquiere e instala en los EE.UU. Esta garantía excluye y no cubre defectos,
averías o fallas del Extractor de aire para baño Hunter que fueran ocasionados por reparaciones por parte de personas no autorizadas
por nosotros, por el uso de piezas o accesorios no autorizados por nosotros, por mal uso, modificaciones, o daños al Extractor de aire
para baño Hunter mientras esté en su posesión, o por un empleo no razonable, incluyendo la falta de suministrar un razonable y
necesario mantenimiento.
Para obtener servicio, contacte con el centro de servicio autorizado Hunter o con nuestro Departamento de servicio de Hunter Fan
Company, en 2500 Frisco Avenue, Memphis, Tennessee 38114. Le agradeceremos que se ponga en contacto con nosotros antes de
enviarnos su Extractor de aire para baño. Si le autorizamos a enviarlo, usted será responsable de todos los cargos de seguro y flete o
de otras cargas del transporte a nuestra planta o centro de reparaciones. Devolveremos su Extractor de aire para baño Hunter con el
flete prepagado. Su Extractor de aire para baño Hunter se debe embalar apropiadamente para evitar daños durante el tránsito ya que
no seremos responsables de dichos daños. Al solicitar un servicio de garantía, debe exhibir una prueba de su compra. El comprador
debe presentar el recibo de compra u otro documento que establezca la prueba de su compra.
EN NINGÚN CASO HUNTER FAN COMPANY SERÁ RESPONSABLE DE DAÑOS PERJUDICIALES O ACCESORIOS.
ALGUNOS ESTADOS NO PERMITEN LIMITACIONES SOBRE LA DURACIÓN DE UNA GARANTÍA IMPLÍCITA O LA EXCLUSIÓN O LIMITACIÓN DE
DAÑOS ACCESORIOS O PERJUDICIALES, POR LO QUE LA LIMITACIÓN O EXCLUSIONES ANTES MENCIONADAS PUEDEN NO APLICARSE
A USTED.
LA GARANTÍA LE DA DERECHOS LEGALES ESPECÍFICOS, PERO USTED TAMBIÉN PUEDE TENER OTROS DERECHOS QUE VARÍAN DE
ESTADO A ESTADO.
41939-02 1/11/2006
2500 Frisco Avenue, Memphis, Tennessee 38114
Impreso en China
41939-02 1/11/2006

Transcripción de documentos

I n s t a l l a t i o n G u 81003 Ashbury Bath Ventilator with Light READ and SAVE THESE INSTRUCTIONS 41939-01 1/11/2006 i d e W a r n i n g TO REDUCE THE RISK OF ELECTRIC SHOCK OR INJURY, OBSERVE THE FOLLOWING: 1. Use this unit only in a manner intended by the manufacturer. If you have questions, contact the manufacturer at the phone number or address listed in the warranty. such as those published by the National Fire Prevention Association (NFPA), and the American Society for Heating, Refrigeration and Air-Conditioning Engineers (ASHRAE), and the local code authorities. 5. When cutting or drilling into wall(s) or ceiling, do not damage electrical wiring or other hidden utilities. 2. B efore installing, servicing, or cleaning the unit, disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location. If you cannot lock the circuit breakers in the off position, securely attach a prominent warning device, such as a tag, to the service panel. 6. Ducted fans must always be vented to the outdoors. Keep ducting as short and as straight as possible. 7. Acceptable for use over a bathtub or shower when connected to a GFCI protected branch circuit. 8. Install fan at least 5 feet (1.52 m) above the floor. 3. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards. 4. S ufficient air is needed for proper combustion and exhausting of gasses through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards, 9. Never place a switch where it can be reached from a tub or shower. 10. This unit must be grounded. 11. F or supply connection, use wires suitable for at least 90º C (194º F). CA U T IO N 1. For general ventilating use only. Do not use for ventilating hazardous or explosive materials. 2. T o avoid motor bearing damage and noisy/unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 3. D  O NOT install this product in a wall. This product is designed for installation in ceilings up to a 12/12 pitch (45 degrees). Ductwork must point upward. 4. Please read specification label on product for further information and requirements. Warning DISCONNECT ELECTRIC POWER SUPPLY AND LOCK OUT SERVICE PANEL BEFORE SERVICING UNIT PREVENTATIVE MAINTENANCE A clean fan provides better service. Disconnect the power supply and clean the fan as listed below. TO CLEAN GRILLE: Use a mild detergent, such as dishwashing liquid, and a soft cloth. DO NOT use abrasive cloths, steel wool pads or scouring powders. TO CLEAN FAN ASSEMBLY: Unplug motor cord from receptacle. To remove motor plate, find the single tab on the motor plate (located next to the receptacle). Push up rear motor plate tab while pushing out on the side of the housing or insert a screwdriver into the slot in the housing (next to tab) and twist screwdriver. Gently vacuum fan, motor and interior of housing. METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER. MAINTENANCE The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the motor with the exact service motor. You should replace the impeller at the same time. 2 41939-01 1/11/2006 Check all the parts. If damaged, call 1-888-830-1326 for replacements. x4 E F G A H * x2 I B 3/8" Cable Connector J *C x2 I * K L Extra Screws M NOTE: Strain relief cable connector must be installed. Not Included. 95029-01-000 75191-01-000 03242-07-133 95491-02-000 74508-03-133 96397-01-444 75184-01-133 85812-03-000 75733-01-444 Included. Tools Needed. (Not supplied.) Before Installation Estimated assembly time: 30 to 60 minutes NOTE: Remove all packing materials before installation. 2 1 I E Turn off the power source. 41939-01 1/11/2006 Loosen screws. 3 3 4 H E Remove packing material. Remove the motor/blower from the housing. 6 5 Remove the pre-loaded screw tip covers. 7 Back out the pre-loaded screw tips until flush with the side of the housing. 8 F G Remove the wiring cover screw. 4 Remove the wiring cover. 41939-01 1/11/2006 9 E 10 C B Pop out the first wiring access slug. Use second if needed. Insert the strain relief (not included) into the housing and secure with washer. Choose Installation Option For New Construction - go to step A11, page 5 For Existing Construction - go to step B11, page 8 New Construction A12 A11 E 5/8 1/2 5/8 1/2 Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. 41939-01 1/11/2006 Screw pre-loaded screws into joist or framing. 5 A13 Route wires through the strain relief. For supply connection, use wires suitable for at least 90º C (194º F). A14 Ground Black Green White A 2 Pin Fan Motor 3 Pin Black Main Switch 1 (AC In) White White Light Bare Copper Black Light *Option Black Switch 2 (AC In) *Option Fan & Main Light Together Connect wires as shown. A16 0 A15 E G F Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. 6 Connect 4” duct and vent to the outside. Tape joints. If ducting does not fit securely, an adapter may need to be purchased. 41939-01 1/11/2006 A17 0 A18 0 H Connect wiring harness. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS. A19 Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. A20 I Secure the motor by tightening the 2 screws. A21 Turn on the power source. A22 ON Go to step C1 OFF on page 10 to attach grille. Test the motor. If the motor does not run, check the plug connection. 41939-01 1/11/2006 7 Existing Construction B11 EXISTING FAN B12 E Remove an existing fan and check to make sure the opening is large enough to accommodate the new motor housing (7 1/4”x 7 3/4”). B13 Move the housing into position above the ceiling. 1 2 B14 Route wires through the strain relief. For supply connection, use wires suitable for at least 90º C (194º F). Attach existing ducting to duct connector. Tape joints. If ducting does not fit securely, an adapter may need to be purchased. B15 E Install the housing flush with the sheetrock and secure by tightening the pre-loaded screws into the joist. 8 41939-01 1/11/2006 B16 Ground Black Green White A 2 Pin Bare Copper Black Main Switch 1 (AC In) Fan Motor White White 3 Pin Light Black Light *Option Black Switch 2 (AC In) *Option Fan & Main Light Together Connect wires as shown. B18 B17 F H G Install the wiring cover plate. B20 B19 H Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. 41939-01 1/11/2006 Connect wiring harness. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS. I Secure the motor by tightening the 2 screws. 9 B21 B22 ON OFF Turn on the power source. B23 Test the motor. If the motor does not run, check the plug connection. Go to step C1 on page 10 to attach grille. Attaching the Grille C2 C1 J L K M Remove the thumbscrews. 10 Remove glass dome. 41939-01 1/11/2006 C3 C4 J J Connect wiring harness. DO NOT ALLOW THE FIXTURE TO HANG FROM THE WIRING HARNESS. C5 Align posts 1, 2, and 3 (stamped into motor housing) with posts 1, 2, and 3 (stamped into light fixture). Slide light fixture over posts. C6 J K Install 2 Max 60 Watt A15 bulbs (Not Included). Attach thumbscrews. WARNING: To reduce the risk of electrical shock, all 4 thumbscrews MUST be properly installed. C7 C8 L M Align glass dome and push up. 41939-01 1/11/2006 Screw glass dome into position. 11 Trouble Shooting Problem: Fan does not come on. Solution: • Hunter Fan Bath Ventilators are extremely quiet. To confirm that the fan is running, place your hand near the vents to feel the air movement. • Turn power on, replace fuse, or reset breaker. • Check all plug connections to be sure they are secure. • Check the wiring to make sure it matches the wiring diagram. Problem: Light does not come on. Solution: • Replace the light bulb with a new bulb. • Turn power on, replace fuse, or reset breaker. • Check all plug connections to be sure they are secure. • Check the wiring to make sure it matches the wiring diagram. Problem: Fan is noisy. Solution: • Check and tighten all fasteners. • Check the glass to make sure it is secure. • Check the flapper to make sure it moves freely. If you need parts or service assistance, please call 888-830-1326 or visit us at our WEB site at http://www.hunterfan.com. 12 41939-01 1/11/2006 Warranty Hunter Fan Company Bath Exhaust Fan LIMITED WARRANTY Hunter Fan Company makes the following limited warranty to the original user or consumer purchaser of this Hunter bath exhaust fan: If any part of your Hunter bath exhaust fan (except for glass fixtures and light bulbs) fails at any time within one year after the date of sale to you due to a defect in material or workmanship, we will repair or, at our option, replace the defective part free of charge for parts and labor performed at our nearest service center or at our Service Department in Memphis, Tennessee. After this one-year period, you will be responsible for all parts and labor costs for repairs on the bath exhaust fan except for motor repairs as provided below. If your Hunter bath exhaust fan motor fails at any time within five years after the date of sale to you due to a defect in material or workmanship, labor and materials to repair the defect will be provided free of charge at our nearest service center or our Service Department in Memphis, Tennessee. If no replacement part can be provided, we will, at our option, either refund the actual purchase price of your bath exhaust fan or provide a replacement free of charge. After this five-year period, you will be responsible for all parts and labor costs for repairs on all parts of the bath exhaust fan. IF THE ORIGINAL USER OR CONSUMER PURCHASER CEASES TO OWN THE FAN, THIS WARRANTY AND ANY IMPLIED WARRANTY WHICH THEN REMAINS IN EFFECT, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE VOIDED. NO WARRANTY, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, IS MADE IN RESPECT OF GLASS FIXTURES OR LIGHT BULBS OR THE FINISH ON ANY METAL PORTION OF THE BATH EXHAUST FAN. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES. THE DURATION OF ANY IMPLIED WARRANTY, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, IN RESPECT TO ANY HUNTER FAN BATH EXHAUST FAN MOTOR OR OTHER FAN PART, IS EXPRESSLY LIMITED TO THE PERIOD OF THE EXPRESS WARRANTY SET FORTH ABOVE FOR SUCH MOTORS OR OTHER PARTS. This warranty is voided if your Hunter bath exhaust fan is not purchased and installed in the U.S.A. This warranty excludes and does not cover defects, malfunctions or failures of any Hunter bath exhaust fan which were caused by repairs by persons not authorized by us, use of parts or accessories not authorized by us, mishandling, improper installation, modifications or damage to the Hunter bath exhaust fan while in your possession, or unreasonable use, including failure to provide reasonable and necessary maintenance. To obtain servicing, contact the nearest Hunter authorized service center of the Hunter Fan Company Service Department, 2500 Frisco Avenue, Memphis, Tennessee 38114. Please contact us before shipping your bath exhaust fan to us. If we authorize you to ship it to us, you will be responsible for all insurance and freight or other transportation charges to our factory or service center. We will return your Hunter bath exhaust fan freight prepaid. Your Hunter bath exhaust fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage. Proof of purchase is required when requesting warranty service. The purchaser must present the sales receipt or other document that establishes proof of purchase. IN NO EVENT SHALL HUNTER FAN COMPANY BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSIONS MAY NOT APPLY TO YOU. THE WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE. 41939-01 1/11/2006 13 2500 Frisco Avenue, Memphis, Tennessee 38114 Printed in China 41939-01 1/11/2006 DESDE G u í a d e i n s t a l a c Ventilador para baño 81003 Ashbury con luz LEA y CONSERVE ESTAS INSTRUCCIONES 41939-02 1/11/2006 i ó n A D V E R T E N C I A PARA REDUCIR EL RIESGO DE DESCARGA ELÉCTRICA O LESIONES, OBSERVE LO SIGUIENTE: 1. Utilice esta unidad sólo de la manera indicada por el fabricante. Si tiene alguna pregunta, contacte con el fabricante en el teléfono o la dirección indicados en la garantía. Protección contra Incendios (NFPA), la Asociación de Ingenieros Americanos en Calefacción y Aire acondicionado (ASHRAE), y los códigos locales. 5. Al cortar o taladrar en paredes o techo, no dañe el cableado eléctrico u otros servicios no visibles. 2. Antes de instalar, dar servicio o limpiar la unidad, desconecte la alimentación eléctrica apagando los interruptores automáticos que alimentan la caja de salida y al interruptor de pared respectivo. Si no puede bloquear los interruptores automáticos en la posición de apagado, fije firmemente una forma destacada de advertencia, como una etiqueta de seguridad, en el tablero de servicio. 6. Los ventiladores canalizados siempre deben descargar al aire libre. Mantenga los ductos tan cortos y rectos como sea posible. 3. Los trabajos de instalación y cableado eléctrico deben ser realizados por personas calificadas de acuerdo con todos los códigos y las normas aplicables, incluyendo los códigos y normas de construcción contra incendio. 8. Instale el ventilador por lo menos a 5 pies (1.52 m) por encima del piso. 4. Se necesita aire suficiente para una combustión adecuada y para evacuar los gases por el tubo de la chimenea de equipo que quema combustible a fin de evitar el flujo inverso. Siga las pautas del fabricante del equipo de calefacción y las normas de seguridad, como las de la Asociación Nacional de 7. Aceptable para uso sobre una bañera o ducha si se conecta en un circuito derivado protegido por un interruptor automático de falla a tierra (GFCI). 9. Nunca coloque un interruptor donde pueda ser alcanzado desde una tina o una ducha. 10. Esta unidad debe ponerse a tierra. 11. Para conexiones de alimentación, use alambres adecuados al menos para 90º C (194º F). tc.Retire las cubiertas de las puntas de tornillo precargadas. PRECAUCIÓN 1. Sólo para uso de ventilación general. No lo utilice para ventilar ambientes con materiales peligrosos o explosivos. 2. P ara evitar daños a los rodamientos del motor e impulsores ruidosos o desbalanceados, mantenga la unidad de potencia lejos de la aplicación de aerosol para paneles de yeso (drywall), polvo de la construcción, etc. 3. N  O instale este producto en una pared. Este producto está diseñado para instalarse en techos con una inclinación de hasta 12/12 (45º). La red de ductos debe dirigirse hacia arriba. 4. Vea más información y los requisitos en la etiqueta de especificación del producto. ADVERTENCIA DESCONECTE LA ALIMENTACIÓN ELÉCTRICA Y CIERRE EL PANEL DE SERVICIO ANTES DE DAR MANTENIMIENTO A LA UNIDAD Mantenimiento preventivo Un ventilador limpio proporciona mejor servicio. Desconecte la alimentación y limpie el ventilador como se indica a continuación. PARA LIMPIAR LA REJILLA: Use un detergente suave, como líquido para lavado de platos, y un paño suave. NO emplee paños abrasivos, almohadillas de lana de acero ni polvos para fregar. PARA LIMPIAR EL CONJUNTO DEL VENTILADOR: Desconecte el cordón del motor de la toma de corriente. Para retirar la placa del motor, encuentre la pestaña en la placa (ubicada junto a la toma de corriente). Levante la pestaña posterior de la placa del motor mientras empuja hacia afuera en el lado del alojamiento o introduzca un destornillador en la ranura del alojamiento (junto a la pestaña) y gire el destornillador. Suavemente aspire el ventilador, el motor y el interior del alojamiento. LAS PARTES METÁLICAS ELÉCTRICAS NUNCA DEBEN SUMERGIRSE EN AGUA. MANTENIMIENTO El motor está lubricado permanentemente y no necesita ser engrasado. Si los rodamientos del motor hacen ruidos excesivos o inusuales, reemplace el motor con el motor de servicio exacto. Debe reemplazar el impulsor al mismo tiempo. 2 41939-02 1/11/2006 Verifique todos los componentes. Si están dañados, llame al 1-888-830-1326 para un reemplazo. x4 E F G A H *B x2 I Conector de cable de 3/8” J *C x2 I K L Tornillos adicionales Debe estar instalado el * Nota: Nota: manguito de alivio de tensión del M 95029-01-000 75191-01-000 03242-07-133 95491-02-000 74508-03-133 96397-01-444 75184-01-133 85812-03-000 75733-01-444 cable. No incluido. Incluido Herramientas necesarias (no suministradas) Tiempo estimado de ensamblaje: entre 30 y 60 minutos Antes de la instalación NOTA: Retire todo el material de embalaje antes de la instalación. 2 1 I E Apague la fuente de alimentación. 41939-02 1/11/2006 Afloje los tornillos. 3 3 4 H E Retire el material de embalaje. Retire el motor/soplador del alojamiento. 6 5 Retire las cubiertas de las puntas de tornillo precargadas. 7 Retire las puntas de tornillo precargadas hasta que estén a nivel con el lado del alojamiento. 8 F G Retire el tornillo de la cubierta del cableado. 4 Retire la cubierta del cableado. 41939-02 1/11/2006 9 E 10 C B Inserte el alivio de tensión (no se incluye) en la caja y sujételo firmemente con una arandela. Expulse el primer tapón metálico de acceso del cableado. Utilice el segundo si es necesario. Escoja la opción de instalación Para construcción nueva -vaya al paso A11, página 5 Para construcción existente - vaya al paso B11, página 8 Construcción nueva A12 A11 E 5/8 1/2 5/8 1/2 Ubique la correcta marca de profundidad en el borde inferior de la viga, según el espesor de su plancha de yeso. 41939-02 1/11/2006 Instale los tornillos precargados en la viga o el marco. 5 A13 Tienda los cables a través del alivio de tension. Para conexiones de alimentación, use alambres adecuados al menos para 90º C (194º F). A14 Tierra 2 pasadores Negro Verde Blanco A Motor del ventilador 3 pasadores Interruptor negro principal 1 (AC) Blanco Blanco Luz Cobre desnudo Negro Luz *Opción Interruptor negro 2 (AC) *Opción Ventilador y luz principal juntos Conecte los alambres como se muestra. A16 0 A15 E G F Instale la placa de cubierta del cableado. Asegúrese que todas las conexiones de cableado estén dentro de la caja o debajo de la placa de cubierta del cableado. 6 Conecte un ducto de 4” y ventile hacia el exterior. Aplique cinta a las uniones. Si el ducto no se ajusta firmemente, puede ser necesario comprar un adaptado. 41939-02 1/11/2006 A17 0 A18 0 H Conecte el mazo de cables. NO PERMITA QUE EL MOTOR CUELGUE DEL MAZO DE CABLES. Vuelva a instalar el motor introduciendo las pestañas y levantando a su posición. Asegúrese que los alambres no se pellizquen entre el motor y el alojamiento. A20 A19 I Encienda la fuente de alimentación. Asegure el motor apretando los 2 tornillos. A21 A22 ENCE NDIDO Vaya al paso C1 APAG ADO en la página 10 para fijar la rejilla. Pruebe el motor. Si el motor no funciona, verifique la conexión del enchufe. 41939-02 1/11/2006 7 Construcción existente B11 VENTILADOR EXISTENTE B12 E Retire el ventilador existente y asegúrese que la abertura sea suficientemente grande para acomodar el alojamiento del motor nuevo (7 1/4” x 7 3/4”). B13 Mueva el alojamiento a su posición encima del techo. 1 2 B14 Tienda los cables a través del alivio de tension. Para conexiones de alimentación, use alambres adecuados al menos para 90º C (194º F). Conecte el ducto existente con el conector de ducto. Aplique cinta a las uniones. Si el ducto no se ajusta firmemente, puede ser necesario comprar un adaptador. B15 E Instale el alojamiento a nivel con la plancha de yeso y asegúrelo apretando los tornillos precargados en la vida. 8 41939-02 1/11/2006 B16 Tierra 2 pasadores Negro Verde Blanco A Cobre desnudo Interruptor negro principal 1 (AC) Motor del ventilador Blanco Blanco Luz 3 pasadores Negro Luz *Opción Interruptor negro 2 (AC) *Opción Ventilador y luz principal juntos Conecte los alambres como se muestra. B17 B18 F H G Instale la placa de cubierta del cableado. B20 B19 H Vuelva a instalar el motor introduciendo las pestañas y levantando a su posición. Asegúrese que los alambres no se pellizquen entre el motor y el alojamiento. 41939-02 1/11/2006 Conecte el mazo de cables. NO PERMITA QUE EL MOTOR CUELGUE DEL MAZO DE CABLES. I Asegure el motor apretando los 2 tornillos. 9 B21 B22 ON OFF Encienda la fuente de alimentación. B23 Pruebe el motor. Si el motor no funciona, verifique la conexión del enchufe. Go to step C1 on page 10 to attach grille. Fijación de la rejilla C2 C1 J L K M Retire los tornillos de mano. 10 Retire le dome de verre. 41939-02 1/11/2006 C4 C3 J J Conecte el mazo de cables. NO PERMITA QUE EL MOTOR CUELGUE DEL MAZO DE CABLES. C5 Alinee los postes 1, 2 y 3 (estampados en la caja del motor) con los postes 1, 2 y 3 (estampados en el artefacto de ilumunación). Deslice la lámpara sobre los postes. C6 J K Instale los tornillos de mano. ADVERTENCIA: Para reducir el riesgo de descarga eléctrica, los 4 tornillos de mano DEBEN instalarse apropiadamente. C7 Instale 2 bombillas A-15 de 60 vatios como máximo. (No incluidas) C8 L M Alinee el domo de vidrio y levante. 41939-02 1/11/2006 Enrosque el dome vidrio en su posición. 11 Solución de problemas Problema: El ventilador no está operando. Solución: • Los ventiladores de baño Hunter son muy silenciosos. Para confirmar que el ventilador esté funcionando, coloque su mano cerca de los conductos de ventilación para sentir el movimiento del aire. • Encienda la alimentación eléctrica, reemplace el fusible o restablezca el interruptor automático. • Verifique todas las conexiones de los enchufes para asegurarse que estén firmes. • Verifique el cableado para asegurarse que coincida con el diagrama de cableado. Problema: La luz no funciona. Solución: • Reemplace la bombilla con una nueva. • Encienda la alimentación eléctrica, reemplace el fusible o restablezca el interruptor automático. • Verifique todas las conexiones de los enchufes para asegurarse que estén firmes. • Verifique el cableado para asegurarse que coincida con el diagrama de cableado. Problema: El ventilador hace ruido. Solución: • Verifique y apriete todos los pernos y tornillos. • Verifique la pantalla para asegurarse que esté firme. • Verifique la válvula de retención para asegurarse que se mueva con libertad. Si necesita repuestos o servicio, llame al 888-830-1326 o visite nuestro sitio web en http://www.hunterfan.com. 12 41939-02 1/11/2006 Garantía Hunter Fan Company Extractor de aire para baño GARANTÍA LIMITADA Hunter Fan Company establece la siguiente garantía limitada al usuario o comprador original de este Extractor de aire para baño Hunter: Si alguna pieza de su Extractor de aire para baño Hunter (con excepción de las lámparas de vidrio y las bombillas) falla en cualquier momento dentro de un año después de la fecha de compra debido a una falla de material o mano de obra, repararemos o, a nuestra elección, reemplazaremos la pieza defectuosa sin costo de partes y mano de obra realizada en nuestro centro de reparaciones más cercano o en nuestro Departamento de servicio en Memphis, Tennessee. Después de este período de un año, usted será responsable de todos los costos de partes y mano de obra para reparaciones del Extractor de aire para baño, con excepción de reparaciones del motor, como se estipula a continuación. Si el motor de su Extractor de aire para baño Hunter falla en cualquier momento dentro de cinco años después de la fecha de compra debido a una falla de material o mano de obra, la mano de obra y los materiales para reparar la falla serán proporcionados sin costo en nuestro centro de reparaciones más cercano o en nuestro Departamento de servicio en Memphis, Tennessee. Si no puede proporcionarse alguna parte de reemplazo, a nuestra elección, le reembolsaremos el precio de compra real de su Extractor de aire para baño o le proporcionamos uno de reemplazo sin costo. Después de este período de cinco años, usted será responsable de todos los costos de partes y mano de obra para reparaciones de cualquier componente del Extractor de aire para baño. SI EL USUARIO O COMPRADOR ORIGINAL DEJA DE POSEER EL EXTRACTOR DE AIRE, ESTA GARANTÍA Y CUALQUIER GARANTÍA IMPLÍCITA QUE PERMANEZCA EN EFECTO, INCLUYENDO PERO SIN LIMITARSE A TODA GARANTÍA IMPLÍCITA DE COMERCIABILIDAD O IDONEIDAD PARA UN PROPÓSITO PARTICULAR, QUEDA ANULADA. NO SE OFRECE NINGUNA GARANTÍA EXPRESA O IMPLÍCITA, INCLUYENDO CUALQUIER GARANTÍA DE COMERCIABILIDAD O IDONEIDAD PARA UN PROPÓSITO PARTICULAR, PARA LAS LÁMPARAS DE VIDRIO O LAS BOMBILLAS O EL ACABADO EN CUALQUIER PARTE METÁLICA DEL EXTRACTOR DE AIRE PARA BAÑO. ESTA GARANTÍA SUSTITUYE A TODAS LAS OTRAS GARANTÍAS EXPRESAS. LA DURACIÓN DE TODA GARANTÍA IMPLÍCITA, INCLUYENDO PERO SIN LIMITARSE A CUALQUIER GARANTÍA IMPLÍCITA DE COMERCIABILIDAD O IDONEIDAD PARA UN PROPÓSITO PARTICULAR, CON RESPECTO DE CUALQUIER MOTOR DE EXTRACTOR DE AIRE PARA BAÑO HUNTER U OTRA PARTE DEL VENTILADOR, ESTÁ EXPRESAMENTE LIMITADA AL PERIODO DE LA GARANTIA EXPRESA ESTABLECIDA ANTERIORMENTE PARA DICHOS MOTORES U OTRAS PARTES. Esta garantía es nula si su Extractor de aire para baño no se adquiere e instala en los EE.UU. Esta garantía excluye y no cubre defectos, averías o fallas del Extractor de aire para baño Hunter que fueran ocasionados por reparaciones por parte de personas no autorizadas por nosotros, por el uso de piezas o accesorios no autorizados por nosotros, por mal uso, modificaciones, o daños al Extractor de aire para baño Hunter mientras esté en su posesión, o por un empleo no razonable, incluyendo la falta de suministrar un razonable y necesario mantenimiento. Para obtener servicio, contacte con el centro de servicio autorizado Hunter o con nuestro Departamento de servicio de Hunter Fan Company, en 2500 Frisco Avenue, Memphis, Tennessee 38114. Le agradeceremos que se ponga en contacto con nosotros antes de enviarnos su Extractor de aire para baño. Si le autorizamos a enviarlo, usted será responsable de todos los cargos de seguro y flete o de otras cargas del transporte a nuestra planta o centro de reparaciones. Devolveremos su Extractor de aire para baño Hunter con el flete prepagado. Su Extractor de aire para baño Hunter se debe embalar apropiadamente para evitar daños durante el tránsito ya que no seremos responsables de dichos daños. Al solicitar un servicio de garantía, debe exhibir una prueba de su compra. El comprador debe presentar el recibo de compra u otro documento que establezca la prueba de su compra. EN NINGÚN CASO HUNTER FAN COMPANY SERÁ RESPONSABLE DE DAÑOS PERJUDICIALES O ACCESORIOS. ALGUNOS ESTADOS NO PERMITEN LIMITACIONES SOBRE LA DURACIÓN DE UNA GARANTÍA IMPLÍCITA O LA EXCLUSIÓN O LIMITACIÓN DE DAÑOS ACCESORIOS O PERJUDICIALES, POR LO QUE LA LIMITACIÓN O EXCLUSIONES ANTES MENCIONADAS PUEDEN NO APLICARSE A USTED. LA GARANTÍA LE DA DERECHOS LEGALES ESPECÍFICOS, PERO USTED TAMBIÉN PUEDE TENER OTROS DERECHOS QUE VARÍAN DE ESTADO A ESTADO. 41939-02 1/11/2006 13 2500 Frisco Avenue, Memphis, Tennessee 38114 Impreso en China 41939-02 1/11/2006
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Hunter Fan 81003 Manual de usuario

Tipo
Manual de usuario

En otros idiomas