Safety Boot SB012-B Guía de instalación

Tipo
Guía de instalación

Este manual también es adecuado para

u INSTALLATION INSTRUCTIONS u
to Anchor the Safety Boot - Different Types of Subfloor Material Require Different
Types of Fasteners In Order to Exceed the 200 lb. OSHA Guardrail Requirement
See inside for detailed illustrations and stress engineering report summary
u IMPORTANT WARNING u
Use the Supplied Drill Adapter with a Power Drill and Socket for Fast and Easy Installation
All specifications and dimensions for building compliant railing systems given within these installation instructions are written to meet United States Federal
OSHA requirements of 1926.502(b)(3), (4), and (5) which are subject to change. Individual U.S. States with their own State run OSHA agencies might have
slightly different and varying specifications for guardrail requirements. Be sure to check and confirm if your particular state follows Federal OSHA or State OSHA
regulations. Always follow the specific safety regulations for your state or region. This system is designed and tested for flat surface applications only.
MAKE SURE EACH PERSON READS AND UNDERSTANDS THESE INSTRUCTIONS PRIOR TO USE. MANUFACTURER ASSUMES NO LIABILITY IN THE EVENT OF IMPROPER
INSTALLATION, PRODUCT MISUSE, OR FAILURE OF WOOD CONSTRUCTION SUBSTRATE. NEVER ALTER OR MODIFY THE SAFETY BOOT. ALWAYS CAREFULLY INSPECT EACH
SAFETY BOOT BEFORE EVERY NEW INSTALLATION. REPLACE IMMEDIATELY IF YOU NOTICE ANY SIGNS OF EXCESSIVE WEAR, DAMAGE, ABUSE OR PLASTIC DEGRADATION.
For Technical Support or to Reorder,
Call Toll Free 1.800.804.4741
www.safetyboot.com u [email protected]
© 2019 SAFETY MAKER, INC.
P.O. Box 880 u Cypress, Texas 77410.0880
Phone 832.593.0400 or 800.804.4741 u Fax 832.593.0910 or 800.914.8019
FREE!
Drill Adapter(s)
Included With
All Orders!
WARNING! NEVER USE NAILS OR UNSPECIFIED FASTENERS
FAILURE TO OBSERVE WARNINGS COULD
RESULT IN SERIOUS INJURY OR DEATH
OSHA REGULATIONS (STANDARDS - 29 CFR)
Guardrail Systems - Non-Mandatory Guidelines for Complying with 1926.502(b) -
1926 Subpart M App B states that for wood railings:
. . . (1) For wood railings: Wood components shall be minimum 1500 lb-ft/in(2) fiber (stress grade) construction grade lumber; the posts shall be at least 2-inch
by 4-inch (5 cm x 10 cm) lumber spaced not more than 8 feet (2.4 m) apart on centers; the top rail shall be at least 2-inch by 4-inch (5 cm x 10 cm) lumber,
the intermediate rail shall be at least 1-inch by 6-inch (2.5 cm x 15 cm) lumber. All lumber dimensions are nominal sizes as provided by the American Softwood
Lumber Standards, dated January 1970 . . .
u FASTENER SPECIFICATIONS u
to Anchor the Safety Boot - Different Types of Subfloor Material Require Different
Types of Fasteners In Order to Exceed the 200 lb. OSHA Guardrail Requirement
FASTENER SPECIFICATIONS FOR VARIOUS TYPES OF SUBFLOOR MATERIAL APPLICATIONS
Use the Supplied Drill Adapter with a Power Drill and Socket for Fast and Easy Installation
SOLID 2X WOOD APPLICATIONS
for solid wood applications use:
u 4 - Hex-Head Lag Screws, X 2 inch
and;
u 4 - X 1-½ Inch Fender Washers
(Fender Washers supplied with all orders)
u Anchor directly into solid 2X lumber using the four
primary corner holes.
STURD-I-FLOOR
®
(1- INCH THICK) PLYWOOD
for Sturd-I-Floor
®
(1- inch thick) plywood applications use:
u 5 - Hex-Head Lag Screws, X 2 inch
and;
u 5 - X 1-½ Inch Fender Washers
(Fender Washers supplied with all orders)
u Anchor directly into Sturd-I-Floor
®
(1- inch thick)
plywood using the four primary corner holes and by
adding a 5th screw on the inside of the guardrail or
stair rail system in the secondary hole provided.
PLYWOOD (LESS THAN 1- INCH THICK)
OR OSB APPLICATIONS
for plywood (less than 1- inch thick) or OSB applications use:
u 4 - Hex-Head Lag Screws, X 3 inch
and;
u 4 - X 1-½ Inch Fender Washers
(Fender Washers supplied with all orders)
u Anchor through the plywood or OSB into floor joists or
solid 2X lumber blocking on the underside of subfloor
using the four primary corner holes.
CONCRETE APPLICATIONS
for concrete applications use:
u 4 - Common Masonry Fasteners or Similar Concrete
Anchors and;
u 4 - X 1-½ Inch Fender Washers
(Fender Washers supplied with all orders)
u Anchor using the four primary corner holes.
Due to the variances in concrete mixtures and applications (such as, concrete
mixture type, psi strength, slab thickness, cure time, etc.), concrete fasten-
ers used to secure the Safety Boot MUST be evaluated on a case by case
basis by a qualified competent person. They should verify that the selected
fastener specifications for average ultimate pullout and shear values are in
compliance with the OSHA required strength standards.* Most concrete fas-
teners are packaged to include a product specification chart that denotes the
average ultimate pullout and shear values in concrete and/or hollow block
applications.
* OSHA STANDARD 1926.502(b)(3):
Guardrail systems shall be capable of withstanding, without failure, a force of
at least 200 pounds (890 N) applied within 2 inches (5.1 cm) of the top edge,
in any outward or downward direction, at any point along the top edge.
FOR OTHER SAFETY BOOT APPLICATIONS
WARNING! NEVER USE NAILS OR UNSPECIFIED FASTENERS
The Safety Boot
®
Guardrail System must always be installed
according to the manufacturers installation instructions. Any
modifications, additions or alterations to the Safety Boot
Guardrail System installation, as stated in these instructions
is not recommended without the close supervision of a Cer-
tified Safety Professional or Safety Engineer. Always verify
through a Certified Safety Professional or Safety Engineer
that your completed system will support the required load
as needed for your specific applications.
ADDITIONAL CONCRETE INFORMATION
u SAFETY BOOT GUARDRAIL SYSTEM u
enables the builder to easily construct freestanding guardrail and stair rail systems that meet OSHA
Regulations on every job-site, even when using different employees or subcontractors.
Use the Supplied Drill Adapter with a Power Drill and Socket for Fast and Easy Installation
for the OSHA Compliance Officer on all temporary guardrail systems (including job-built railings).
[Subpart M — Appendix B]
SEE INSIDE FOR DETAILED ILLUSTRATIONS AND STRESS ENGINEERING REPORT SUMMARY
Call Toll Free 1.800.804.4741
www.safetyboot.com u info@safetyboot.com
© 2019 SAFETY MAKER, INC.
P.O. Box 880 u Cypress, Texas 77410.0880
Phone 832.593.0400 or 800.804.4741 u Fax 832.593.0910 or 800.914.8019
ADDITIONAL WARNINGS FOR HOIST AREAS
THE GENERAL / PRIME CONTRACTOR IS RESPONSIBLE
for assembling to OSHA standards, all of the various temporary railing systems mandated for different workplace situations.
u IMPORTANT INFORMATION u
ADDITIONAL WARNINGS FOR STEEL DECKING
OSHA STANDARDS REQUIRE THAT ENGINEERING TEST DATA CERTIFICATION MUST BE AVAILABLE
FOR TECHNICAL SUPPORT OR TO REORDER
FAILURE TO OBSERVE WARNINGS COULD RESULT IN SERIOUS INJURY OR DEATH
DO NOT use sheet metal screws to anchor the Safety Boot Guardrail System directly into steel decking (e.g., 18 - 22
gauge B-Deck, F-Deck or similar corrugated steel decking). Sheet metal screws, self starting screws or similar are NOT capable
of withstanding a 200 pound load in corrugated steel decking and DO NOT meet United States Federal OSHA guardrail regulations.
Each employee in a hoist area shall be protected from falling 6 feet (1.8 m) or more to lower levels by guardrail
systems or personal fall arrest systems. If guardrail systems, (or chain, gate, or guardrail) or portions thereof, are
removed to facilitate the hoisting operation (e.g., during landing of materials), and an employee must lean through the access
opening (to receive or guide equipment and materials, for example), that employee shall be protected from fall hazards by a
personal fall arrest system. [§1926.501(b)(3) Duty to have fall protection]
u STEP ONE u
Assemble Posts
Applies to Walking / Working Surfaces and Stairway Landings
u STEP TWO u
Placement of Posts
u STEP THREE u
Anchor Posts to Surface
u STEP FOUR u
Fasten Rails to Posts & Insert Toeboard
u Cut 2X4 lumber into two 42 inch lengths.
DO NOT use wet or oversized lumber.
u Fasten the lengths together with
screws or nails to form a post.
u Place one end of the post into the
top of the Safety Boot and tap until
the bottom of the post is flush with
the bottom of the Safety Boot.
u Be sure and anchor the
Safety Boot to the post using
one Hex-Head Lag Screw,
X 2 inch with provided washer.
Assemble Guardrails Using (Stress Grade)
Construction Grade Lumber
u Place Safety Boot Posts in line along all edges of
unprotected walking/working surfaces of stairways,
balconies, landings, roofs, on parapets, elevator
shafts, bridges, etc.
u Space between the Posts MUST NOT exceed Eight
(8) feet according to OSHA guidelines.
u Place Safety Boot Posts a max-
imum of Eighteen (18) inches
on center away from all
permanent wall structures.
(Always leave ample room for
drywall installation, if required).
Placement of Posts Should be Along
Unprotected Sides or Edges
NOTE
Maximum Distance
of 8 Feet
Between the Posts
u Securely fasten Safety Boots to surface using specified
fasteners (see previous page) and provided washers.
u You MUST always use the correct fasteners for
different types of flooring — To meet OSHA strength
requirements refer to the Fastener Specifications Section
in this instruction booklet for your specific subfloor
application.
u DO NOT USE NAILS TO ANCHOR THE BOOTS!
ALWAYS USE THE CORRECT FASTENERS!
Anchor Posts to Subfloor Surface
u For Stair rails, including Handrails, top railings must
be attached to the posts at approximately 39-40 inches.
u For Guardrails, including Landings, top railings must
be flush with top of posts (42 inches).
u For all Mid-rails, fasten halfway between top railing
and flooring.
u Terminal (End) System, always extend the railings past
the posts and stop the railings four (4) inches from any
permanent structure. EXCEPTION: Where there is no
permanent structure, the ends of the rails must stop at
the terminal post to prevent a projection hazard.
u For Toeboards, (required by OSHA), cut 2X4’s to fit
tight between two posts and drop into toeboard slots
on each Safety Boot. (Toeboards are not required on
stair rail systems).
Fasten Top Rails and Mid Rails to Posts
and Insert Toeboards Between Posts
1926.1052(c)(7) states: When the top edge of a stairrail system also serves as a handrail, the height of the
top edge shall be not more than 37 inches (94 cm) nor less than 36 inches (91.5 cm) from the upper surface of
the stairrail system to the surface of the tread, in line with the face of the riser at the forward edge of the tread.
Cut Toeboards to Fit
Tight & Drop into
Slots on Safety Boots.
NOTE
MAXIMUM DISTANCE
BETWEEN POSTS
8 FEET ON CENTERS
P
E
R
M
A
N
E
N
T
W
A
L
L
S
T
R
U
C
T
U
R
E
4 - INCH
CLEARANCE
MAXIMUM
DISTANCE
18 INCHES
TO CENTER
OF POST
TOP RAIL --
2" X 4" STUD (SMOOTH SURFACED - SANDED)
TOE BOARD --
2" X 4" STUD
(NOT MORE THAN ¼" ABOVE SURFACE)
TOP RAIL MUST BE
42 INCHES (± 3")
IN HEIGHT
MID RAIL MUST BE
HALFWAY BETWEEN
TOP RAILING
AND SURFACE
UNPROTECTED SIDE OR EDGE OF PERMANENT STRUCTURE
MID RAIL --
AT LEAST 1" X 6"
(
2" X 4" OK)
P
E
R
M
A
N
E
N
T
C
O
L
U
M
N
S
T
R
U
C
T
U
R
E
MAXIMUM
DISTANCE
18 INCHES
TO CENTER
OF POST
Extend the top rails and midrails past the terminal posts
and stop the rails four (4) inches from the permanent
structures to prevent an unprotected opening.
See Exception under STEP FOUR.
MIDRAIL
MUST BE
HALFWAY
TOPRAIL
MUST BE
42 INCHES (± 3")
IN HEIGHT
MIDRAILMUSTBE
HALFWAYBETWEEN
TOPRAIL
ANDSURFACE
UNPROTECTED SIDE OR EDGE
OF ASTAIRWAYLANDING
TOPRAIL--
2" X4"STUD
(SMOOTHSURFACED--SANDED)
MIDRAIL--
AT LEAST1"X6"
(2"X4" IS ACCEPTABLE)
STAIRRAIL
MUST BE
36 -37INCHES
IN HEIGHT
FASTEN STAIRRAIL
AT 39 -40INCHES
IN HEIGHT
HANDRAILS ANDTHE TOP RAILS
of stairrailsystems shallbecapable of
withstanding,without failure, aforce of
at least200 pounds appliedwithin2
inches of thetop edge,inany downward
or outwarddirection,atany pointalong
thetop edge.
[§1926.1052Stairways (c)(5)]
FASTEN STAIRRAIL
AT 39 -40INCHES
IN HEIGHT
Applies to Unprotected Sides or Edges - Subpart M—§1926.502 Fall Protection Systems Criteria and Practices
Applies to Stairways, Handrails, Stair Rail Systems and Stairway Landings - Subpart X—Stairways and Ladders
u STEP FIVE u
Remove & Reuse Posts at Next Job Site
NOTE
1926.1052(c)(7) states: When the top edge of a stairrail
system also serves as a handrail, the height of the top edge
shall be not more than 37 inches (94 cm) nor less than 36
inches (91.5 cm) from the upper surface of the stairrail sys-
tem to the surface of the tread, in line with the face of the
riser at the forward edge of the tread.
NOTE
Illustration Below
Applies to
Odd Angled Surfaces
NOTE
Leave Ample Room
(at least 4 inches)
for Drywall Installation
Ï
SUMMARY OF TESTS PERFORMED ON THE
SAFETY BOOT
®
PERFORMED FOR
SAFETY MAKER, INC.
PERFORMED BY
STRESS ENGINEERING SERVICES
HOUSTON, TEXAS
W. T. Asbill, P.E.
JULY 15, 2002
Revised April 11, 2003
STRESS ENGINEERING SERVICES (SES) IS A MULTI-DISCIPLINE ENGINEERING COMPANY THAT SERVES
A VARIETY OF INDUSTRIES. ONE OF THE SERVICES PROVIDED BY SES IS A TEST FACILITY IN WHICH A
VARIETY OF PRODUCTS ARE TESTED.
A SERIES OF TESTS WERE PERFORMED FOR SAFETY MAKER ON THEIR SAFETY BOOT
®
. THE PURPOSE
OF THE TESTS WERE TO DETERMINE THE MAXIMUM LOAD THE BOOT AND FLOOR ASSEMBLY COULD
WITHSTAND. THE TESTS WERE PERFORMED ACCORDING TO OSHA 1926.502 WHICH IS A CONSTRUC-
TION REGULATORY GUIDE FOR FALL PROTECTION GUARDRAIL SYSTEMS. THIS GUIDE REQUIRES THAT
THE GUARDRAIL SYSTEM MUST BE ABLE TO WITHSTAND A FORCE OF 200 POUNDS AT A HEIGHT OF 42”
ABOVE THE FLOOR.
A NUMBER OF TESTS WERE PERFORMED USING A VARIETY OF BOLTS AND SUBFLOORS. BELOW IS A
TABLE AND PLOT THAT SUMMARIZES SOME OF THE TEST RESULTS. IN ALL TESTS SHOWN, THE SAFE-
TY BOOT ASSEMBLY EXCEEDED THE OSHA REQUIREMENT OF 200 POUNDS FORCE. THE TESTS HAVE
SHOWN THAT IT IS IMPORTANT TO HAVE THE CORRECT COMBINATION OF LAG BOLT SIZE, WASHER
SIZE, NUMBER OF LAG BOLTS AND FLOOR MATERIAL THAT THE SAFETY BOOT IS ATTACHED TO. SOME
FLOOR MATERIALS, SUCH AS PLYWOOD LESS THAN 1-1/8” THICK AND OSB, ARE INSUFFICIENT BY
THEMSELVES AND MUST HAVE ADDITIONAL SUPPORT (2” PINE BOARD) FOR THE BOLTS TO PENETRATE.
WITH THE ATTACHMENT COMBINATIONS SUMMARIZED, THE SAFETY BOOT EASILY EXCEEDED THE OSHA
MINIMUM REQUIREMENT OF 200 POUNDS FORCE.
SUMMARY OF SELECTED SAFETY BOOT
®
STRESS TESTS PERFORMED BY SES
TEST NO. & TEMPERATURE LAG BOLT FENDER WASHER SUBFLOOR MATERIAL MAX. FORCE POUNDS
1 : Room 3/8” x 3” 3/8” x 1-1/4” 23/32” STURD-I-FLOOR Plywood & 2” x 10” Yellow Pine 488
2 : Room 3/8” x 3” 3/8” x 1-1/4” 23/32” STURD-I-FLOOR Plywood & 2” x 10” Yellow Pine 502
3 : Room 3/8” x 3” 3/8” x 1-1/4” 23/32” STURD-I-FLOOR Plywood & 2” x 10” Yellow Pine 467
4 : 0°F 3/8” x 3” 3/8” x 1-1/4” 23/32” STURD-I-FLOOR Plywood & 2” x 10” Yellow Pine 680
5 : -13°F 3/8” x 3” 3/8” x 1-1/4” 23/32” STURD-I-FLOOR Plywood & 2” x 10” Yellow Pine 574
6 : -15°F 3/8” x 3” 3/8” x 1-1/4” 23/32” STURD-I-FLOOR Plywood & 2” x 10” Yellow Pine 542
7 : Room 3/8” x 2” 3/8” x 1-1/4” 2” x 10” Yellow Pine 420
8 : Room 3/8” x 2” 3/8” x 1-1/4” 2” x 10” Yellow Pine 407
9 : Room 3/8” x 2” 3/8” x 1-1/4” 2” x 10” Yellow Pine 435
10 : Room 3/8” x 2” 3/8” x 1-1/2” 2” x 10” Yellow Pine 337
11 : Room 3/8” x 2” 3/8” x 1-1/2” 2” x 10” Yellow Pine 405
12 : Room 3/8” x 2” 3/8” x 1-1/2” 2” x 10” Yellow Pine 430
13 : Room 3/8” x 2” 3/8” x 1-1/2” 1-1/8” STURD-I-FLOOR Plywood 387
14 : Room 3/8” x 2” 3/8” x 1-1/2” 1-1/8” STURD-I-FLOOR Plywood 530
15 : Room 3/8” x 2” 3/8” x 1-1/2” 1-1/8” STURD-I-FLOOR Plywood 504
SAFETY BOOT
®
ENGINEERING STRESS TEST RESULTS
¡ADVERTENCIA! NUNCA USAR CLAVOS O SUJETADORES NO ESPECIFICADOS
u INSTRUCCIONES DE INSTALACION u
para anclar la Safety Boot (Cubierta de Seguridad) – Tipos diferentes de material de contrapiso requieren
tipos diferentes de sujetadores para cumplir con el requisito de OSHA de 200 lb. de resistencia de la baranda
Vea en las páginas interiores, las ilustraciones detalladas y el resumen del informe de ingeniería de esfuerzo
Para Instalación Rápida y Fácil, utilice el Adaptador Suministrado de Taladro con un Taladro Mecánico y Casquillo
Todas las especificaciones y dimensiones para los sistemas de pasamano obedientes del edificio dados dentro de estas instrucciones de instalación se escriben a los
requisitos federales de Estados Unidos OSHA de la reunión de 1926.502 (b) (3), (4), y (5) que están conforme a cambio. Los E.E.U.U. individuales Los estados con sus
propias agencias dirigidas por el gobierno del OSHA pudieron tener especificaciones levemente diversas y que variaban para los requisitos de la barandilla. Sea seguro
comprobar y confirmar si su estado particular sigue regulaciones federales del OSHA o del OSHA del estado. Siga siempre las regulaciones específicas de seguridad para
su estado o región. Este sistema se diseña y se prueba para los usos superficiales planos solamente.
CERCIÓRESE DE QUE CADA PERSONA LEA Y QUE ENTIENDA ESTAS INSTRUCCIONES ANTES DE USO. LA FALTA DE OBSERVAR ESTA ADVERTENCIA PODÍA DAR LUGAR A LESIÓN O A MUERTE
SERIA. EL FABRICANTE NO ASUME NINGUNA RESPONSABILIDAD EN CASO DE LA INSTALACIÓN, DEL USO ERRÓNEO DEL PRODUCTO, O DE LA FALTA INCORRECTO DEL SUBSTRATO DE MADE-
RA DE LA CONSTRUCCIÓN. NUNCA ALTERE O MODIFIQUE LA SEGURIDAD BOOT
®
. EXAMINE SIEMPRE CUIDADOSAMENTE CADA SEGURIDAD BOOT ANTES DE CADA NUEVA INSTALACIÓN.
SUBSTITUYA INMEDIATAMENTE SI USTED NOTA CUALESQUIERA MUESTRAS DEL DESGASTE, DEL DAÑO, DEL ABUSO O DE LA DEGRADACIÓN EXCESIVO DEL PLÁSTICO.
REGLAMENTOS DE OSHA (NORMAS – 29 CFR)
Sistemas de Barandas – Las pautas No obligatorias para cumplir con la Subparte M
Apéndice B 1926.502(b) – 1926 establecen para barandas de madera:
. . . (1) Para barandas de madera: los componentes de madera deberán soportar como mínimo 1500 libras-pie/pulgada (2) la fibra (grado de resistencia) de la made-
ra, de calidad para construcción; los postes deberán ser de madera de por lo menos 2 pulg. por 4 pulg. (5 cm x 10 cm) separados no más de 8 pies (2,4 m) entre los
ejes; la baranda superior deberá ser de madera de por lo menos 2 pulg. por 4 pulg. (5 cm x 10 cm); la baranda intermedia deberá ser de madera de por lo menos 1
pulg. por 6 pulg. (2,5 cm x 15 cm). Todas las dimensiones de la madera son medidas nominales según lo estipulado en las Normas Americanas sobre Madera Blanda,
en enero de 1970 . . .
Para Apoyo Técnico o Para Volver a Pedir,
Llame Gratuitamente al 800.804.4741
www.safetyboot.com u [email protected]
© 2019 SAFETY MAKER, INC.
P.O. Box 880 u Cypress, Texas 77410.0880
Teléfono 832.593.0400 or 800.804.4741 u Fax 832.593.0910 or 800.914.8019
FREE!
Taladro Adapter(s)
Incluido con Todos los
Pedidos!
u AVISO IMPORTANTE u
EL INCUMPLIMIENTO DE ESTAS ADVERTENCIAS
PODRÍA RESULTAR EN LESIONES GRAVES O LA MUERTE
u ESPECIFICACIONES DE SUJETADORES u
para anclar la Safety Boot (Cubierta de Seguridad) – Tipos diferentes de material de contrapiso requieren
tipos diferentes de sujetadores para cumplir con el requisito de OSHA de 200 lb. de resistencia de la baranda
APLICACIONES PARA MADERA MACIZA 2X
para usar en madera maciza:
u 4 - Tirafondos de cabeza hexagonal, de x 2
pulgadas y;
u 4 - Arandelas protectoras de X 1-½ pulgadas
(Se proveen arandelas protectoras con todos
los pedidos)
u Anclar (sujetar) directamente en madera maciza de con-
strucción 2X usando los cuatro primeros huecos de esquina.
MADERA CONTRACHAPADA STURD-I-FLOOR
®
(1- PULG. DE ESPESOR)
para usar en madera contrachapada Sturd-I-Floor
®
( 1- de espesor):
u 5 - Tirafondos de cabeza hexagonal, de x 2
pulgadas y;
u 5 - Arandelas protectoras de X 1-½ pulgadas
(Se proveen arandelas protectoras con todos
los pedidos)
u Anclar (sujetar) directamente en la madera contrachapada Sturd-I-
Floor
®
(1- pulgadas de espesor) usando los cuatro primeros hueco
de esquina y añadir un quinto tornillo en el lado interno del sistema
de baranda o barandas de escalera, en el hueco secundario provisto.
APLICACIONES PARA MADERA
CONTRACHAPADA (DE MENOS DE
1- PULG. DE ESPESOR) U OSB
para usar en aplicaciones de madera contrachapada
(de menos de 1- de espesor) u OSB:
u 4 - Tirafondos de cabeza hexagonal, de x 3
pulgadas y;
u 4 - Arandelas protectoras de X 1-½ pulgadas
(Se proveen arandelas protectoras con todos
los pedidos)
u Anclar (sujetar) a través de la madera contrachapada u OSB a las
vigas de piso o al entramado de madera maciza 2X del lado de abajo
del contrapiso, usando los cuatro primeros huecos de esquina.
APLICACIONES PARA CONCRETO
para las aplicaciones sobre concreto, usar:
u 4 - Común Fijaciones de mampostería o análogas
Anchors concretas y;
u 4 - Arandelas protectoras de X 1-½ pulgadas
(Se proveen arandelas protectoras con todos los pedidos)
u Anclar usando los cuatro primeros huecos de esquina.
IMPORTANTE: Debido a las variaciones en las mezclas y aplicaciones de concreto
(tal como el tipo de mezcla de concreto, resistencia a la presión, espesor de la losa,
tiempo de curado, etc.), los sujetadores para concreto usados para sujetar la Safety
Boot (Cubierta de Seguridad) DEBEN ser evaluados en cada caso por una persona
competente habilitada. Esta persona debería verificar que las especificaciones para
valores promedio de extracción y de esfuerzo cortante del sujetador seleccionado
cumplen con las normas de resistencia exigidas por OSHA.* La mayoría de los
sujetadores para concreto van acompañados en el paquete de una tabla de especifi-
caciones del producto que indica los valores promedio de extracción y de esfuerzo
cortante en aplicaciones sobre concreto y/o bloque hueco.
* NORMA OSHA 1926.502(b)(3):
Los sistemas de barreras de protección deben ser capaces de soportar, sin falla, una
fuerza de por lo menos 200 libras (890 N) aplicada a menos de 2 pulgadas (5,1
cm) del borde superior, ya sea hacia afuera o hacia abajo, en cualquier punto a lo
largo del borde superior.
PARA OTRAS APLICACIONES DE CONTRAPISO
ESPECIFICACIONES DE SUJETADORES PARA VARIOS TIPOS DE APLICACIONES EN MATERIAL DE CONTRAPISO
Para Instalación Rápida y Fácil, utilice el Adaptador Suministrado de Taladro con un Taladro Mecánico y Casquillo
¡ADVERTENCIA! NUNCA USAR CLAVOS O SUJETADORES NO ESPECIFICADOS
El sistema de barandas Safety Boot® debe instalarse siempre de acuerdo
con las instrucciones de instalación del fabricante. No se recomienda ninguna
modificación, adición o alteración de la instalación del sistema de barandillas
de seguridad, tal como se indica en estas instrucciones, sin la estricta super-
visión de un profesional de seguridad certificado o un ingeniero de seguridad.
Verifique siempre a través de un profesional de seguridad certificado o un
ingeniero de seguridad que su sistema completo soportará la carga requerida
según sea necesario para sus aplicaciones específicas.
u INFORMACIÓN ADICIONAL u
u SISTEMAS DE BARANDAS SAFETY BOOT u
permiten que el constructor ensamble con facilidad sistemas autosoportantes de pasamanos y barandas que cumplen
con las Normas OSHA en cada sitio de trabajo aun cuando se empleen trabajadores o subcontratistas distintos.
Para Instalación Rápida y Fácil, utilice el Adaptador Suministrado de Taladro con un Taladro Mecánico y Casquillo
para el Funcionario Encargado de Cumplimiento de Normas OSHA en todos los sistemas de barandas temporales
(incluyendo barandas construidas en la obra).
[Subparte M – Apéndice B]
VEA EN LAS PAGINAS INTERIORES, LAS ILUSTRACIONES DETALLADAS
Y EL RESUMEN DEL INFORME DE INGENIERIA DE ESFUERZO.
Llame Gratuitamente al 800.804.4741
www.safetyboot.com u info@safetyboot.com
© 2019 SAFETY MAKER, INC.
P.O. Box 880 u Cypress, Texas 77410.0880
Teléfono 832.593.0400 or 800.804.4741 u Fax 832.593.0910 or 800.914.8019
ADVERTENCIAS ADICIONALES PARA ÁREAS DE ALZAMIENTO
Cada empleado en una zona de elevación, será protegido de caer 6 pies (1,8 m) o más, a niveles más bajos por sistemas de ba
randas o por sistemas personales de prevención de caídas. Si el sistema de barandas, (o cadenas, barrera o pretil) o porciones de
ellas, son retiradas para facilitar la operación de elevación (por ejemplo, durante la descarga de materiales) y un empleado debe inclinarse a
través de la abertura de acceso (para recibir o guiar equipo y materiales, por ejemplo), ese empleado estará protegido del peligro de caerse,
mediante un sistema personal de prevención de caídas. [§ 1926.501(b)(3) Obligación de tener protección para caídas].
EL CONTRATISTA GENERAL/PRINCIPAL ES EL RESPONSABLE
de instalar según las normas de OSHA, todos los sistemas de barandas temporales, exigidos para diferentes situaciones en el lugar de trabajo.
PARA APOYO TÉCNICO O PARA VOLVER A PEDIR
EL INCUMPLIMIENTO DE ESTAS ADVERTENCIAS PODRÍA RESULTAR EN LESIONES GRAVES O LA MUERTE
LAS NORMAS OSHA EXIGEN QUE LA CERTIFICACION DE DATOS DE PRUEBAS DE INGENIERIA ESTEN DISPONIBLES
ADVERTENCIAS ADICIONALES PARA EL ACERO
NO utilice tornillos de rosca chapa que ancla el sistema de barandilla de seguridad arranque directo en acero (p. ej., B-cubierta de
calibre 18-22, F-Deck, etc. acanalado del acero). Tornillos para chapa, tornillos auto partidos, etc. NO son capaces de soportar una
carga de 200 libras en acero corrugado decking y NO cumplir con Reglamento de barandilla de OSHA Federal de Estados Unidos.
u PASO UNO u
Montaje de Postes
Se Aplica a Superficies de Trabajo/Caminar y a Descansos de Escalera
u PASO DOS u
Colocación de Postes
u PASO TRES u
Anclar Postes al Piso
u PASO CUATRO u
Sujete las barandas a los postes e
introduzca tablas de guardia
u Corte un pie derecho de 2 x 4 en dos tramos de
42 pulgadas cada uno. NO USE madera
mojada o sobredimensionada.
u Junte los tramos con tornillos o clavos
para formar un poste.
u Coloque un extremo del poste en la parte
superior de la Cubierta de Seguridad y
golpee ligeramente hasta que el fondo
del poste quede a ras con el fondo de
la Cubierta.
u Asegúrese de anclar la Cubierta
de Seguridad al poste usando un
Tirafondos de Cabeza Hexagonal
de X 2 pulgada con arandela.
Instale los postes utilizando pies
derechos de 2 x 4
u Coloque los postes de la Cubierta de Seguridad alineándolos a
lo largo de todos los bordes de las superficies sin protección
para trabajo y caminar, de escaleras, balcones, descansos,
techos, en parapetos, cajas de ascensores, puentes, etc.
u El espacio entre los Postes NO DEBE exceder Ocho (8)
pies de acuerdo con las normas OSHA.
u Coloque los Postes de la Cubierta de Seguridad a Dieciocho
(18) pulgadas del centro apartados de toda estructura
permanente de pared.
(Siempre deje suficiente espacio
para los obreros del muro seco si
es necesario).
La colocación de los postes debe ser a lo
largo del lado o borde sin protección
NOTA
MAXIMO 8 PIES
ENTRE
LOS POSTES
u Sujete firmemente la Cubierta de Seguridad al piso
usando sujetadores especificados.
u Siempre SE DEBEN usar los sujetadores correctos para
tipos diferentes de piso - Para cumplir con los
requisitos de resistencia OSHA, consulte la Sección
de Especificaciones de Sujetadores en este folleto de
instrucciones para su aplicación específica del contrapiso.
u ¡NO UTILICE CLAVOS PARA ANCLAR LOS BOOTS!
¡SIEMPRE USE LOS SUJETADORES CORRECTOS!
Anclar los postes a la superficie del contrapiso
u Para barandas de escaleras, incluyendo pasamanos, las
barandas superiores deben estar fijadas a los postes a
aproximadamente 39-40 pulgadas.
u Para las barandas, incluyendo descansos, las barandas
superiores deben estar a ras con la parte superior de
los postes (42 pulgadas).
u Para las barandas centrales, sujete a la mitad entre la
baranda superior y el piso.
u El Sistema Terminal (de Extremo) siempre extiende las
barandas más allá de los postes y detiene las barandas
a Cuatro (4) pulgadas de cualquier estructura permanente.
EXCEPCION: Cuando no hay estructura permanente,
los extremos de las barandas deben terminarse en el
poste terminal para impedir un peligro de saliente.
u Para tablas de guardia (que exige OSHA), corte maderos de
2 x 4 para que encajen bien apretados entre dos postes e
introdúzcalos en las ranuras de las tablas de guardia en cada
Cubierta de Seguridad. (No se requieren tablas de guardia en barandas).
Sujete las barandas superiores y las del medio a los
postes e introduzca tablas de guardia entre los postes
los Estados 1926.1052(c)(7):
cuando el borde superior de un sistema de stairrail también sirve como un pasamanos, la altura
del borde superior será no más de 37 pulgadas (94 cm) ni menos de 36 pulgadas (91.5 cm) de la
superficie superior del sistema stairrail a la superficie de la escultura, en consonancia con la cara de
las bandas en el borde hacia delante de la escultura.
Coloque las tablas
de guardia dentro
de las ranuras
NOTA
Se Aplica a los Lados y Bordes Sin Protección – Subparte M – § 1926.502 Criterios y Prácticas de los Sistemas de Protección para las Caídas
Se Aplica a Escaleras, Pasamanos, Sistema de Pasamanos de Escalera y Descansos de Escalera – Subparte X – Escaleras y Escalas
u PASO CINCO u
Retirar y reutilizar los postes en la próxima obra
NOTA
los Estados 1926.1052(c)(7): cuando el borde superior
de un sistema de stairrail también sirve como un pasamanos, la
altura del borde superior será no más de 37 pulgadas (94 cm)
ni menos de 36 pulgadas (91.5 cm) de la superficie superior del
sistema stairrail a la superficie de la escultura, en consonancia con
la cara de las bandas en el borde hacia delante de la escultura.
NOTA
Ilustración siguiente
se refiere a Odd
superficies inclinadas
NOTA
Deje espacio para la
instalación del muro
de mampostería
Ï
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Safety Boot SB012-B Guía de instalación

Tipo
Guía de instalación
Este manual también es adecuado para

en otros idiomas