Westinghouse 7220500 Manual de usuario

Categoría
Ventiladores domésticos
Tipo
Manual de usuario
1
ETL-ES-Barnett-WH18
OWNER'S MANUAL
MANUAL DEL USUARIO
Barnett
Please write model number here for future reference: /
Por favor, incluya el número del modelo aquí para futura referencia:
Net Weight: LBS
Peso Neto: KGS
2
ETL-ES-Barnett-WH18
1. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards (ANSI/NFPA 70), including fire-rated construction.
2. Use this unit only in the manner intended by the manufacturer. If you have any questions contact the manufacturer.
3. After making the wire connections, gently push connections into outlet box with wire nuts pointing up. The wires should be spread apart with the grounded conductor and the equipment-grounding conductor on
one side of the outlet box and ungrounded conductor on the other side of the outlet box.
4. Before you begin installing the fan, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be
locked, securely fasten a prominent warning device, such as a tag, to the service panel.
5. Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.
6. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
7. Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade.
8. To reduce the risk of fire, electric shock, or personal injury, this fan must be mounted to an outlet box marked suitable for fan support, and use the mounting screws provided with the outlet box. (Mounting must
support at least 35 lbs.)
9. WARNING! Do not bend blade holders during installation to motor, balancing or during cleaning. Do not insert foreign object between rotating blades.
10. Attach the mounting bracket using only the hardware supplied with the outlet box. Fan is only to be mounted to an outlet box marked Acceptable for Fan Support.
11. WARNING! To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.
12. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.
13. NEVER place a switch where it can be reached from a tub or shower.
14. The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment manufacturer’s guideline safety standards such as those
published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
15. Before servicing or cleaning unit, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be
locked, securely fasten a prominent warning device, such as a tag, to the service panel.
16. All set screws must be checked and re-tightened where necessary before installation.
17. The appliance is not intended for use by young children or infirmed persons without supervision. Young children should be supervised to ensure that they do not play with the appliance.
TOOLS REQUIRED
Phillips Screwdriver Wire Cutters Pliers Step Ladder
SAFETY TIPS
OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR PERSONAL INJURY, MOUNT TO OUTLET BOX MARKED 'ACCEPTABLE FOR FAN SUPPORT OF 35 LBS (15.9 KG) OR LESS' AND
USE MOUNTING SCREWS PROVIDED WITH THE OUTLET BOX AND/OR SUPPORT DIRECTLY FROM BUILDING STRUCTURE. MOST OUTLET BOXES COMMONLY USED FOR THE SUPPORT OF
LUMINARIES ARE NOT ACCEPTABLE FOR FAN SUPPORT AND MAY NEED TO BE REPLACED. CONSULT A QUALIFIED ELECTRICIAN IF IN DOUBT.
3
ETL-ES-Barnett-WH18
1. El trabajo de instalación y el cableado eléctrico los deben efectuar personas calificadas cumpliendo con todos los códigos y las normas aplicables (ANSI/NFPA 70), incluyendo las de incendio.
2. Use esta unidad sólo de la manera en que el fabricante quiere que se haga. Si tiene dudas, llame al fabricante.
3. Después de hacer las conexiones, empuje con cuidado las conexiones dentro de la caja de embutir con los conectores de cables mirando hacia arriba. Se deben separar los cables: el conductor de puesta a tierra y el conductor
de puesta a tierra del equipo a un lado de la caja de embutir, y el conductor que no tiene puesta a tierra del otro lado de la misma.
4. Antes de comenzar a instalar el ventilador, apague la alimentación en el panel de servicio y bloquee el medio de desconexión del servicio para evitar que se encienda accidentalmente. Cuando no se puede bloquear el medio
de desconexión del servicio eléctrico, fije de manera segura y un dispositivo de advertencia prominente, como un rótulo, al panel de servicio.
5. ¡Tenga cuidado! Lea todas las instrucciones y la información de seguridad antes de instalar su ventilador nuevo. Revise los diagramas de montaje incluidos.
6. Al cortar o perforar una pared o el techo, no dañe el cableado eléctrico y otras instalaciones de servicios públicos ocultos.
7. Asegúrese de que el sitio para la instalación que escoja permita que el ventilador gire libremente sin obstrucciones. Deje un espacio mínimo de 7 pies desde le piso hasta el borde posterior de la aleta.
8. Para reducir el riesgo de incendios, choques eléctricos o heridas graves personales, este ventilador se debe montar sobre una caja de embutir que tenga una marca que indique que es adecuada para soportar un ventilador.
Además debe utilizar los tornillos correspondientes incluidos con la caja de embutir. (El montaje debe soportar por lo menos 35 lbs.)
9. ¡ADVERTENCIA! No doble los soportes para las aleta durante la instalación al motor, al balancear o durante la limpieza. No inserte objetos extraños entre las aleta mientras giran.
10. Fije el soporte de montaje usando sólo la tornillería suministrada con la caja de embutir. El ventilador sólo se debe montar en una caja de embutir marcada Acceptable for Fan Support” (Aceptable para soportar ventiladores).
11. ¡ADVERTENCIA! Para reducir el riesgo de incendios o choques eléctricos, no use este ventilador con un dispositivo de control de velocidad de estado sólido para ventilador, o un control de velocidad variable.
12. Si esta unidad se instalará sobre una bañera o una ducha, debe estar identificada como adecuada para ese tipo de aplicación.
13. NUNCA coloque un interruptor donde se pueda alcanzar desde una bañera o una ducha.
14. Es posible que la operación de esta unidad afecte el flujo de aire de combustión necesario para la operación segura de equipo que quema combustible. Siga la directrices de seguridad del fabricante de equipo de calefacción
como las publicadas por la Asociación Nacional de Protección Contra Incendios (National Fire Protection Association, NFPA), y la Sociedad Americana para Ingenieros de Calefacción, Refrigeración y Aire Acondicionado
(American Society for Heating, Refrigeration and Air Conditioning Engineers, ASHRAE) y las autoridades del código local.
15. Antes de efectuar tareas de servicio o limpieza en la unidad, apague la alimentación en el panel de servicio y bloquee el medio de desconexión del servicio para evitar que se encienda accidentalmente. Cuando no se puede
bloquear el medio de desconexión del servicio eléctrico, fije de manera segura y un dispositivo de advertencia prominente, como un rótulo, al panel de servicio.
16. Antes de realizar la instalación, es importante comprobar y volver a ajustar todos los tornillos, según corresponda.
17. El dispositivo no ha sido diseñado para ser utilizado por niños o personas enfermas sin supervisión. Los niños deben ser supervisados para asegurarse de que no juegan con el dispositivo.
HERRAMIENTAS NECESARIAS
Destornillador Phillips Pinzas de corte Pinzas Escalera de mano
CONSEJOS DE SEGURIDAD
HAGA LO SIGUIENTE: LEA Y GUARDE ESTAS INSTRUCCIONES
ADVERTENCIA: PARA REDUCIR EL RIESGO DE INCENDIO, DESCARGA ELÉCTRICA O HERIDAS GRAVES PERSONALES, MONTE EN UNA CAJA DE EMBUTIR ROTULADA “ADECUADA PARA VENTILADORES DE 35 LBS (15,9
KG) O MENOS” UTILIZANDO LOS TORNILLOS DE MONTAJE INCLUIDOS CON LA CAJA DE EMBUTIR Y/O MONTE DIRECTAMENTE EN LA ESTRUCTURA DEL EDIFICIO. LA MAYORÍA DE LAS CAJAS DE EMBUTIR UTILIZADAS
NORMALMENTE CON ARTEFACTOS DE ILUMINACIÓN NO SON ADECUADAS PARA VENTILADORES Y DEBERÍAN SER REEMPLAZADAS. SI TIENE PREGUNTAS, CONSULTE A UN ELECTRICISTA CALIFICADO.
4
ETL-ES-Barnett-WH18
COMBO-BLADE
Combo-Blades feature two high quality finishes on one blade. Select the one that best complements
your decor, or change the style with just a flip of the blade.
NOTE: Combo-Blade finishes vary, depending upon model.
ALETAS DE DOBLE CARA
Las aletas del rotor de doble cara presentan dos superficies con un acabado de alta calidad. Invirtiendo
las aletas puede producir un efecto decorativo adaptado a su ambiente o crear una decoración
completamente nueva.
Observación: las superficies de las aletas de doble cara son distintas dependiendo del modelo.
FEATURES
CARACTERÍSTICAS
DOWNROD
INSTALLATION
INSTALACIÓN CON
VARILLA VERTICAL
For normal ceilings
Para techos normales
5
ETL-ES-Barnett-WH18
Unpack and inspect fan carefully to be certain all contents are included.
Turn off power at fuse box to avoid possible electrical shock.
1
Use metal outlet box suitable for fan support (must support 35 lbs).
Before attaching fan to outlet box, ensure the outlet box is securely
fastened by at least two points to a structural ceiling member (a loose
box will cause the fan to wobble).
2
PREPARING FOR INSTALLATION
ANTES DE LA INSTALACIÓN
Quite el envoltorio e inspeccione detenidamente el ventilador para verificar
que todas las piezas estén incluidas. Apague la alimentación en la caja de
fusibles para evitar la posibilidad de descarga eléctrica.
Use una caja de embutir de metal adecuada para soportar un ventilador
(debe soportar 35 libras). Antes de fijar el ventilador a la caja de embutir
asegúrese de que la misma esté fijada de manera segura en por lo menos
dos puntos a un miembro estructural del techo (una caja suelta haría
que el ventilador oscile).
6
ETL-ES-Barnett-WH18
MOUNTING BRACKET INSTALLATION
INSTALACIÓN CON SOPORTE DE MONTAJE
Afloje pero no quite los tornillos en la parte inferior del dosel;
extraiga el soporte de montaje del dosel.
3
Loosen but don’t remove the screws at the bottom of canopy;
remove the mounting bracket from the canopy.
Instale el soporte de montaje a la caja de embutir del techo con la tornillería
suministrada con la caja de embutir.
4
Install mounting bracket to outlet box in ceiling using the screws and washers
provided with the outlet box.
7
ETL-ES-Barnett-WH18
3
5
MOUNTING OPTIONS
OPCIONES DE MONTAJE
Choose a MOUNTING OPTION
Elija una OPCIÓN DE MONTAJE
NORMAL DOWNROD OPTION
If installing downrod supplied with fan, proceed to page 7, step 6.
OPCIÓN CON VARILLA VERTICAL NORMAL
Si instala la varilla vertical incluida con el ventilador,
proceda a la página 7, paso 6.
EXTENDED DOWNROD OPTION
If installing with longer downrod than supplied with fan, proceed to page 9, step 8.
OPCIÓN CON VARILLA VERTICAL MÁS LARGA
Si instala una varilla vertical más larga que la que se incluye con el
ventilador, proceda a la página 9, paso 8.
NORMAL DOWNROD OPTION
OPCIÓN CON VARILLA VERTICAL NORMAL
Quite el pasador tipo prensa (1) desde el pasador transversal (2) de la vara (3).
6
Remove clamp pin (1) and cross pin (2) from downrod (3).
1
2
3
8
ETL-ES-Barnett-WH18
DOWNROD INSTALLATION
INSTALACION DE LA VARILLA VERTICAL
Loosen (but do not remove) the set screws from the down rod coupling. Place downrod assembly into canopy and coupling cover. Insert motor wires through the downrod and
insert the downrod into the downrod coupling. Make sure to align the hole in the downrod with the hole in the downrod coupling. Install cross pin (1) removed in step 6 through
coupling and downrod. Insert clamp pin (2) into cross pin until it snaps into place. Tighten set screws (3) in coupling. Slide coupling cover (4) onto the downrod. PROCEED TO
PAGE 11, STEP 11.
Afloje (pero no quite) los tornillos de fijación del acoplamiento de la varilla vertical. Coloque el conjunto de la varilla vertical dentro del dosel y la cubierta del acoplamiento. Inserte
los cables del motor a través del conjunto de la varilla vertical y inserte la varilla vertical en el acoplamiento de la varilla vertical. Asegúrese de que el agujero de la varilla vertical y
el del acoplamiento de la varilla vertical estén alineados. Instale el pasador transversal (1) pasándolo por el acoplamiento y la varilla vertical. Inserte el pasador tipo prensa (2) en
el pasador transversal hasta que escuche un chasquido que indique que está en la posición adecuada. Ajuste los tornillos de fijación (3) en el acoplamiento. Deslice la cubierta del
acoplamiento (4) sobre el acoplamiento de la varilla vertical. PROCEDA A LA PÁG. 11, PASO 11.
7
1
4
3
2
9
ETL-ES-Barnett-WH18
8
Loosen the downrod ball (1) from downrod (2) by removing the screw
(3).
Afloje la bola de la varilla vertical (1) de la varilla vertical (2) quitando
el tornillo (3).
2
3
1
EXTENDED DOWNROD OPTION
OPCIÓN CON VARILLA VERTICAL MÁS LARGA
9
Slide downrod ball (1) off of downrod and remove pin (2).
Deslice la bola de la varilla vertical (1) hasta separarla de la varilla vertical y
quite el pasador (2).
2
1
10
ETL-ES-Barnett-WH18
DOWNROD PREPARATION
PREPARANDO LA VARILLA VERTICAL
Re-install pin into extended downrod, and slide downrod ball up to the top of the downrod. Re-install the set screw to secure ball to downrod. Note: Some extended down-
rods have a pre-drilled set-screw hole. If a pre-drilled hole is present in the extended downrod, tighten the set screw into the pre-drilled hole in the extended downrod. If
no pre-drilled hole exists in the extended downrod, tighten the screw against the downrod to secure the downrod ball. PROCEED TO PAGE 8, STEP 7.
Vuelva a instalar el pasador en la varilla vertical más larga y deslice la bola de la varilla hasta el extremo superior de la misma. Vuelva a insertar el tornillo de fijación para
asegurar la bola a la varilla vertical. Nota: Algunas varillas verticales más largas tienen un agujero previamente perforado para el tornillo. Si la varilla vertical más larga tiene
un agujero previamente perforado, ajuste el tornillo en el agujero previamente perforado de la varilla vertical más larga. Si la varilla vertical más larga no tiene un agujero
previamente perforado, ajuste el tornillo sobre la varilla vertical para asegurar la bola de la misma. PROCEDA A LA PÁG. 8, PASO 7.
10
11
ETL-ES-Barnett-WH18
MOUNTING
MONTAJE
11
Carefully lift fan assembly onto mounting bracket. Rotate fan until notch
on downrod ball (1) engages the ridge on the mounting bracket (2). This
will allow for hands free wiring.
Levante con cuidado el conjunto del ventilador hasta el soporte de montaje.
Gire el ventilador hasta que la muesca de la bola de la varilla vertical (1)
enganche sobre la saliente del soporte de montaje (2). De este modo, tendrá
las dos manos libres para hacer el cableado.
This remote control unit is equipped with 16 code combinations to prevent possible
interference from or to other remote units. The frequency switches on your receiver and
transmitter have been preset at the factory. Please recheck to make sure the switches on
transmitter and receiver are set to the same position, any combination of settings will
operate the fan as long as the transmitter and receiver are set to the same position.
Esta unidad de control remoto está equipada con 16 códigos de combinación para
prevenir posibles interferencias con otras unidades de control remoto. Los interruptores de
frecuencia en su receptor y transmisor han sido programados en fábrica. Por favor verifique
que los interruptores en el transmisor y el receptor estén en la misma posición, cualquier
combinación hará funcionar el ventilador siempre y cuando el transmisor y el receptor
estén en la misma posición.
12
WIRING OPTIONS
OPCIÓN DE CABLEADO
12
ETL-ES-Barnett-WH18
WIRING OPTIONS
OPCIÓN DE CABLEADO
14
Once wiring step has been completed, slide the wired remote receiver in between the
mounting bracket and the top of the downrod ball for downrod fans.
Al terminar la instalación del cableado, deslice el receptor remoto alámbrico entre el
soporte de montaje y la parte superior de la bola de la vara.
13
Bare Copper or Green
Cobre Pelado o Verde
Green
Verde
Green
Verde
Make wiring connections from the house and the motor to the remote receiver as shown
above. Connect using wire nuts (provided).
Haga las conexiones de cableado del alojamiento y el motor al receptor remoto como se
indica arriba. Utilice las tuercas para cables (incluidas).
13
ETL-ES-Barnett-WH18
SECURE TO CEILING
ASEGURE EL VENTILADOR AL TECHO
15
Raise the canopy up and align the keyholes on the bottom of the canopy with the 2 screws on the bottom of mounting bracket. Rotate the canopy to engage the keyholes with the protruding
screws. Tighten the screws to secure the canopy.
Suba el dosel y alinee las ranuras bocallaves de la parte inferior del dosel con los 2 tornillos de la parte inferior del soporte de montaje. Gire el dosel para enganchar las ranuras bocallaves con
los tornillos que sobresalen. Ajuste los tornillos para asegurar el dosel.
14
ETL-ES-Barnett-WH18
17
BLADE INSTALLATION
INSTALACIÓN DE LAS ALETAS
16
Attach blade brackets to blades using the blade bracket screws (1) and fabric
washers (2).
Fije los soportes para aletas a las aletas con los tornillos (1) y las arandelas de tela
(2).
1
2
Attach the blade bracket assembly to the motor as shown, and use the provided
motor screws to tighten the blade brackets to the motor.
Note: for your convenience motor screws and spring washers may be pre-installed
to the motor.
Conecte el montaje de los soportes para aletas al motor como se muestra, y utilice los
tornillos del motor incluidas para apretar los soportes para aletas al motor.
Nota: Para su conviniencia los tornillos del motor y las arandelas elásticas puede estar
pre-instalado al motor.
15
ETL-ES-Barnett-WH18
LIGHT FIXTURE INSTALLATION
INSTALACIÓN DEL ARTEFACTO LUMINOSO
18
Remove the screws (1) from the light kit mounting plate (2) and keep
them for use with light kit installation on the step #22.
Retire los tornillos (1) de la placa de montaje del artefacto luminoso (2)
y guardalos para uso en paso #22.
1
2
19
Attach the upper cage (1) to light kit cover (2) using three screws (3) provided.
Monte la jaula superio (1) en la cubierta del artefacto luminoso (2) con los tres tor-
nillos (3) provistos.
3
2
1
16
ETL-ES-Barnett-WH18
LIGHT FIXTURE INSTALLATION
INSTALACIÓN DEL ARTEFACTO LUMINOSO
Install light bulbs. Use E26 base, Max.40W light bulbs.
Instale las bombillas. Utilice bombillas con casquillo E26 de máximo 40 W.
20
Carefully raise the lower cage onto the upper cage, make sure to align the iron
wires between both upper and lower parts of the cage. Pull the clamp (1) from the
lower shade over the upper cage so that it engages the iron wire (2) of the upper
cage until it snaps into place. Note: Make sure the 3 clamps are tightly secured to
the upper cage with the lower cage.
Levante con cuidado la jaula inferior sobre la jaula superior, asegúrese de alinear las barras
de hierro entre las partes superior e inferior de la jaula. Enganche la abrazadera (1) de la
jaula inferior sobre la jaula superior para que encaje en la barra de hierro (2) de la jaula
superior hasta que encaje en su lugar. Nota: asegúrese de que las 3 abrazaderas estén
firmemente sujetas a la jaula superior con la jaula inferior.
21
2
1
17
ETL-ES-Barnett-WH18
LIGHT FIXTURE INSTALLATION
INSTALACIÓN DEL ARTEFACTO LUMINOSO
Connect the plug from the light kit (2) to the plug from the ceiling fan housing (1)
together. Attach the switch housing (2) onto the switch housing cover (1) for assem-
bly. Secure tightly with side screws from step #18.
Conecte el enchufe del artefacto luminoso (2) al enchufe del alojamiento del ventilador de
techo (1) juntos. Coloque el artefacto luminoso (2) en la el alojamiento del ventilador de techo
(1) para su montaje. Asegúrela firmemente con los tornillos laterales del paso 18.
22
To reverse the direction of the blades, slide the reverse switch (located on the switch hous-
ing) to the opposite side. Note: Make sure slide switch is pushed firmly to one side or the
other. The fan will not operate with the slide switch in the middle.
Para invertir el sentido de las paletas, deslice el interruptor de marcha atrás (ubicado en la
carcasa del conmutador) hacia el lado opuesto. Nota: Asegúrese de que el interruptor de
tipo deslizante esté firmemente situado en una de sus dos posiciones. El ventilador no fun-
cionará si el interruptor de tipo deslizante está situado en el medio.
23
2
1
18
ETL-ES-Barnett-WH18
Mount the transmitter holder onto the wall using screws provided. Place the transmitter into the holder.
Monte el soporte para el transmisor a la pared usando los tornillos incluidos. Coloque el transmisor en el soporte.
LIGHT
LOW
MED
HIGH
OFF
M.LOW
24
19
ETL-ES-Barnett-WH18
25
LIGHT
LOW
MED
HIGH
OFF
M.LOW
Remote Control Operation
1. Fan Control– press and release. The remote control
operates the fan speed as follows: OFF, turns fan off; HIGH, highest fan
speed; MED, medium fan speed; M.LOW, medium low fan speed; LOW,
low fan speed.
2. Light On/Off – press and release light button.
3. Light Dimmer – continuous pressure on the light button
dims light in a continuous cycle from light to dark, or dark to light.
Operación con control remoto
1. Control del ventilador: presione y suelte. El control remoto
controla las velocidades del ventilador de la siguiente
manera: OFF, apaga el ventilador; HIGH, alta velocidad; MED, mediana
velocidad; M.LOW, mediana baja velocidad; LOW, baja velocidad.
2. Luz encendida/apagada –presionar y soltar el botón de luz.
3. Conmutador de intensidad – al presionar continuamente el
botón de luz, esta última conmuta en un ciclo continuo de
más claro a más oscuro o de más oscuro a más claro.
20
ETL-ES-Barnett-WH18
OPERATION AND MAINTENANCE
Operation
Turn on the power and check operation of fan.
Speed settings for warm or cool weather depend on factors such as room size, ceiling height, number of fans and so on.
The slide switch controls direction, forward or reverse.
Warm weather/down position - (Forward) Fan turns counterclockwise direction. A downward air flow creates a cooling effect as shown in illustration A.
This allows you to set your air conditioner on a higher temperature setting without affecting your comfort.
Cool weather/up position - (Reverse) Fan turns clockwise direction. An upward airflow moves warm air off the ceiling area as shown in illustration B.
This allows you to set your heating unit on a lower setting without affecting your comfort.
NOTE: Turn off and wait for fan to stop before changing the setting of the forward/reverse slide switch.
Maintenance
1. Because of the fans natural movement, some connections may become loose. Check the support connections, brackets, and blade attachments twice a year.
Make sure they are secure.
2. Clean your fan periodically to help maintain its new appearance over the years. Do not use water when cleaning.
This could damage the motor, or the wood, or possibly cause electrical shock.
3. Use only a soft brush or lint-free cloth to avoid scratching the finish. The plating is sealed with a lacquer coating to minimize discoloration or tarnishing.
4. There is no need to oil your fan. The motor has permanently lubricated bearings.
21
ETL-ES-Barnett-WH18
OPERACIÓN Y MANTENIMIENTO
Operación
Encienda el ventilador y verifique su funcionamiento.
Las velocidades para clima cálido o frío dependen de factores como el tamaño de la habitación, la altura del ventilador, el número de ventiladores, etc.
El interruptor deslizante controla la dirección, hacia adelante o hacia atrás.
Clima cálido/posición hacia abajo - (Adelante) El ventilador gira en sentido contrahorario. Una corriente de aire descendente crea un efecto refrescante
como lo indica la ilustración A. Esto le permite ajustar el aire acondicionado a una temperatura más alta sin que afecte su comodidad.
Clima frío/posición hacia arriba - (Atrás) El ventilador gira en sentido de las agujas del reloj. Una corriente de aire ascendente aleja el aire caliente
del área del ventilador de techo como lo indica la ilustración B. Esto le permite ajustar la calefacción a un nivel más bajo sin que afecte su comodidad.
NOTA: Apague el ventilador y espere a que se detenga antes de cambiar la dirección hacia adelante/atrás con el interruptor deslizante.
Mantenimiento
1. El movimiento natural del ventilador podría hacer que se aflojen algunas conexiones. Verifique las conexiones de soporte, las piezas de fijación y los accesorios de las aletas
dos veces al año. Asegurese de que estén aseguradas.
2. Limpie el ventilador periódicamente para ayudar a mantener su apariencia nueva con el correr de los años. No use agua para limpiarlo, ya que podría dañar el motor o la
madera o causar descarga eléctrica.
3. Use sólo un cepillo blando o un trapo sin pelusa para no rayar el acabado. El enchapado está sellado con una capa de laca para minimizar la decoloración o pérdida del brillo.
4. No hay necesidad de aceitar el ventilador. El motor tiene cojinetes de lubricación permanente.
22
ETL-ES-Barnett-WH18
TROUBLESHOOTING GUIDE
If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation, or wiring. In some cases, these
installation errors may be mistaken for defects. If you experience any faults, please check this troubleshooting chart. If a problem cannot be
remedied, please consult with your qualified electrician and do not attempt any electrical repairs yourself.
TROUBLE
1. If fan does not start:
2. If fan sounds noisy:
3. If fan wobbles:
4. If light does not work:
SUGGESTED REMEDY
1. Check main and branch circuit fuses or circuit breakers.
2. Check wire connections as performed in step #13 of installation. CAUTION: Make sure main power is turned off.
3. Make sure forward/reverse switch is firmly in up or down position. Fan will not operate when switch is in the middle.
4. If the fan still will not start, contact a qualified electrician. Do not attempt to troubleshoot internal electrical connections yourself.
1. Check to make sure all screws in motor housing are snug (not over tightened).
2. Check to make sure the screws which attach the fan blade holder to the motor are tight.
3. Some fan motors are sensitive to signals from Solid State variable speed controls. DO NOT USE a Solid State variable speed control.
4. Allow “break-in period of 24 hours. Most noises associated with a new fan will disappear after this period.
All blades are weighed and grouped by weight. Natural woods vary in density which could cause the fan to wobble even though all blades are weight-matched. The following procedures should
eliminate most of the wobble. Check for wobble after each step.
1. Check that all blades are screwed firmly into blade holders.
2. Check that all blade holders are tightened securely to motor.
3. Make sure that canopy and mounting bracket are tightened securely to ceiling joist.
4. If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can redistribute the weight and possibly result in smoother operation.
1. Check for faulty light bulbs.
2. Check to see that the wire connections in the switch housing are connected.
3. If light kit will still not operate, contact a qualified electrician for assistance.
23
ETL-ES-Barnett-WH18
GUÍA PARA SOLUCIONAR PROBLEMAS
Si tiene dificultades para hacer funcionar su nuevo ventilador, podría ser a causa del armado, instalación o cableado incorrectos. En algunos
casos, estos errores de instalación podrían ser confundidos con defectos. Si experienca algun fallo, consulte esta guía para solucionar
problemas. Si no puede solucionar el problema, consulte a un electricista calificado y no intente reparar conexiones eléctricas.
PROBLEMA
1. Si el ventilador no arranca:
2. Si el ventilador es ruidoso:
3. Si el ventilador oscila:
4. Si la luz no funciona:
SOLUCIÓN SUGERIDA
1. Compruebe los fusibles o disyuntores principales y del circuito derivado.
2. Compruebe el cableado del bloque de terminales como lo hizo en el paso No. 13 de la instalacn. ADVERTENCIA: Asegúrese de que la alimentación principal esté apagada.
3. Asegúrese de que el interruptor de marcha adelante/atrás esté firmemente en su posición. El ventilador no funcionará si el interruptor está en la posicion del medio.
4. Si el ventilador no arranca, póngase en contacto con un electricista calificado. No intente reparar conexiones eléctricas internas.
1. Compruebe para asegurarse de que todos los tornillos del alojamiento del motor estén ajustados (no los apriete demasiado).
2. Compruebe para asegurarse de que los tornillos que fijan el soporte de la aleta del ventilador al motor estén apretados.
3. NO USE un control de velocidad variable de estado sólido.
4. Permita el "rodaje" del ventilador durante un período de 24 horas. La mayoría de los ruidos asociados con el ventilador nuevo desaparecerán después de este período.
Todas las aletas se pesan y agrupan según el peso. Las maderas naturales varían en densidad y podrían hacer que el ventilador oscile aún cuando todas las aletas estén agrupadas por peso. Los
siguientes procedimientos deberían eliminar la mayoría de los problemas de oscilación. Verifique la oscilación después de cada paso.
1. Verifique que todas las aletas estén firmemente atornilladas a los soportes de las aletas.
2. Verifique que todos los soportes de las aletas estén firmemente aseguradas al motor.
3. Asegúrese de que el dosel y el soporte de montaje estén firmemente asegurados a la viga del techo.
4. Si la oscilación de la aleta sigue siendo visible, es posible que al intercambiar dos aletas adyacentes (lado a lado) se redistribuya el peso y el funcionamiento sea más suave.
1. Compruebe si hay lámparas defectuosas.
2. Verifique que el conector molex del alojamiento del interruptor esté conectado.
3. Si el conjunto de luces no funciona, póngase en contacto con un electricista calificado.
24
ETL-ES-Barnett-WH18
PARTS LIST
LISTA DE REPUESTOS
1
3
4
7
5
6
2
LIGHT
LOW
MED
HIGH
OFF
M.LOW
# Description
1 .......... Mounting Bracket (assembled with Canopy)
2 .......... Blade Bracket (qty. 5)
3 .......... Blade (qty 5)
4 .......... Cage
5 .......... Remote control
6 .......... Capacitor
7 .......... Hardware pack
8 .......... Down Rod Assembly (includes down rod ball, cross
pins, clamp pin)
9 .......... Motor Assembly
10......... Light Kit Assembly
No. . . . . . . . . . . . . . .Descripción
1 .......... Soporte de montaje (assemblado con el soporte de
mnotaje)
2 .......... Soporte para aleta (qty. 5)
3 .......... Aleta (qty 5)
4 .......... Jaula
5 .......... Control remoto
6 .......... Condensador
7 .......... Tornillería
8 ..........
Assemblaje de la varilla vertical (incluye la bola de la
varilla vertical, passador transversal, pasador de fijacion)
9 .......... Asemblaje del motor
10 ........ Asemblaje del artefacto luminoso
8
9
10
25
ETL-ES-Barnett-WH18
26
ETL-ES-Barnett-WH18
27
ETL-ES-Barnett-WH18
28
ETL-ES-Barnett-WH18
Westinghouse Lighting, Philadelphia, PA 19154-1029, U.S.A.
www.westinghouselighting.com
, WESTINGHOUSE, and INNOVATION YOU CAN BE SURE OF
are trademarks of Westinghouse Electric Corporation.
Used under license by Westinghouse Lighting
All rights reserved.
Made in China
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Westinghouse 7220500 Manual de usuario

Categoría
Ventiladores domésticos
Tipo
Manual de usuario

En otros idiomas