MODEL 9518
New 5/01 2 5084033
CAUTION: THE SECONDARY SUPPORT CABLE PROVIDED
SHOULD BE USED ANYTIME THE CIRCULATOR IS MOUNTED
OVERHEAD FOR ADDITIONAL SAFETY.
SECONDARY SUPPORT CABLE
1. Loop one end of Cable around the Large Diameter Wires of both the
Front and Rear Circulator Guard.
(Figure 4)
2. Attach a Cable Clamp with the "U" on the tail side of the loop leaving
a tail approximately 1 to 2 inches. Tighten Clamp Nuts. Make sure no
part of the Cable interferes with the Blade
. (Figure 4)
3. Wrap the other end of the Cable around a secure building joist, truss,
or other support near the Fan.
(Figure 3)
Take up all excess slack in
the Cable.
CAUTION: USE ONLY THE MOUNTING HARDWARE WHICH
IS RECOMMENDED FOR USE ON THIS FAN.
4. Attach the remaining Cable Clamp as indicated in
Step 2
. The excess
tail should be trimmed to extend 1 to 2 inches past the Clamp.
5. Check the Assembly to assure the Blade is free of all obstructions.
CAUTION: USE OF THE SECONDARY SUPPORT CABLE DOES NOT
GUARANTEE PROTECTION AGAINST INJURY OF PERSONS,
MOUNTING OF BOTH THE CIRCULATOR AND CABLE COULD FAIL
IF SUBJECTED TO ABUSE, NEGLECT OR IMPROPER INSTALLATION.
OPERATION
1. Plug the power cord into a properly grounded three-prong receptacle.
2. Using the Pull Cord Switch, set the desired Fan Speed.
3. WARNING: This fan should be used only in a clean, dry environment.
Mounting of this product in any way other then specified in the instruc-
tion sheet will null and void the manufacturers warranty
..
MAINTENANCE
WARNING: ALWAYS UNPLUG CORD BEFORE SERVICING.
CLEANING: Use a soft cloth and a mild soap solution such as liquid dish
washing detergent.
CAUTION: Do not use gasoline, benzine, thinner, harsh cleaners,
etc. which will damage the Fan.
Dry all parts with a soft cloth completely before reconnecting to power supply.
STORAGE: When not in use, keep unit in a clean dry place.
MOTOR IS PERMANENTLY LUBRICATED.
Large Guard Wires
Figure 4
Figure 3
Secondary
Support
Cable
LIMITED WARRANTY
SHOULD ACCESSORY PARTS BE NEEDED, CONTACT THE MANUFACTURER FOR IN-WARRANTY REPLACEMENT PARTS. A COPY OF PROOF-
OF-PURCHASE MUST BE INCLUDED ALONG WITH THE TYPE AND STYLE, WHICH IS LOCATED ON THE BOTTOM OF YOUR APPLIANCE.
This product is warranted for one year from the date of original purchase against defects in workmanship and/or materials. At our option, parts that prove
to be defective will either be repaired or replaced or the whole product will be replaced.
Should electrical or mechanical repair become necessary during the warranty period, send your complete product, postage or frei ght
pre-paid to the nearest service center. Call the number below for the service station nearest you.
Should a part need replacement, you must give us the type and style of your appliance. You will find this at the bottom of the appliance. In either case,
a copy of your proof of purchase is requested.
This warranty does not apply if the damage occurs because of accident, improper handling or operation, shipping damage, abuse, misuse, unauthorized
repairs made or attempted, or the use of the product for commercial service.
ALL WARRANTIES, EXPRESSED OR IMPLIED, LAST FOR ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE. THIS WARRANTY DOES
NOT COVER LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR ANY CAUSE WHATSOEVER.
Some states do not allow limitations on how long any implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so
that the above limitations and exclusions may not apply to you. This warranty gives you specific legal rights. You may also have other rights which vary
from state to state.
FOR PARTS:
Check package contents. If parts are missing, or replacement parts required, please call our PARTS DEPARTMENT TOLL-FREE AT 1-800-966-2028.
MONDAY THROUGH FRIDAY, BETWEEN THE HOURS OF 8 AM AND 4 PM EST. "PLEASE DO NOT RETURN PRODUCT TO PLACE OF
PURCHASE." Reference the type and style of product (located on the underside of the product) when you call.
FOR TECHNICAL ASSISTANCE and SERVICE CENTER LOCATIONS:
For any questions, comments or the location of your nearest service center, PLEASE CALL OUR TOLL-FREE "HOTLINE" AT 1-800-233-0268. MONDAY
THROUGH FRIDAY, BETWEEN THE HOURS OF 8 AM AND 5 PM EST. Please reference product name and model no. when you call.
Appliance Service Dept. • P.O. Box 569 Franklin, TN 37065-0569 PLEASE DO NOT SEND PRODUCT TO THIS LOCATION!
Commercial Style fan
WARNING
:
This fan should be used only in a
clean, dry environment. Mounting of this product
in any way other than specified in the instruction
sheet will null and void the manufacturers warranty.
LEA Y GUARDE ESTAS INSTRUCCIONES
LÉALAS CUIDADOSAMENTE ANTES DE INTENTAR ARMAR, INSTALAR, OPERAR O DAR MANTENIMIENTO AL PRODUCTO DESCRITO.
PROTÉJASE A SÍ MISMO Y A LOS DEMÁS OBSERVANDO TODA LA INFORMACIÓN SOBRE SEGURIDAD. ¡NO SEGUIR LAS
INSTRUCCIONES PODRÍA RESULTAR EN LESIONES PERSONALES Y/O DAÑOS A LA PROPIEDAD!
GUARDE LAS INSTRUCCIONES PARA REFERENCIAS FUTURAS.
MANUAL DE INSTRUCCIONES DE OPERACIÓN Y PARTES
DESCRIPCIÓN
AirKing de ventilador para piso o para mesa y de 18" (45.7 cm) se caracteriza
por el funcionamiento silencioso como murmullo con paleta de ventilador
dividida en tres. Tiene motor lubricado permanentemente con juego de
alambre 18/3 de 9 pies (2.7 m).
ESPECIFICACIONES
Motor ............................................... 120V, 50/60Hz
Tamaño de paletas ......................... 18" (45.7 cm) Modelo 9518
Velocidades .................................... 3
Control ............................................ Cordón Accionador
Distribución del lujo de aire ............ 360°
Aprobaciones................. Catalogación UL. El protector de malla cerrada
del ventilador satisface las normas OSHA.
VENTILADOR DE ALTA
VELOCIDAD Y
MONTAJE EN
PARED DE
18" (45.7 cm)
18" (45.7 cm) MODELO 9518
MODELO
9518
VELOCIDAD
ALTA MEDIA BAJA
CFM 5350 4180 3010
M
3
/s 2.52 1.97 1.42
RPM 600 1275 950
Amps .65 1.27 .95
Watts 194 148 110
dB A 67 58 49
GENERAL SAFETY INFORMATION
INFORMACIÓN GENERAL SOBRE SEGURIDAD
1. Cerciórese de que la fuente de electricidad se adapte a los requerimientos
eléctricos del ventilador.
2. El cordón eléctrico está equipado con una clavija a tierra de tres espigas
que tiene que ser enchufada a un recept áculo del mismo dise ño. Bajo
ninguna circunstancia deberá cortarse la espiga a tierra de la clavija. De
existir un receptáculo de pared de dos espigas, deberá reemplazarse por
uno de tres espigas debidamente puesto a tierra e instalado de conformidad
con el Código Nacional de Electricidad y todos los códigos y ordenanzas
locales aplicables. El trabajo deber á hacerlo un electricista calificado,
utilizando exclusivamente alambre de cobre.
ADVERTENCIA: NO SE RECOMIENDA EL USO DE UN ADAPTADOR DE
TRES A DOS ESPIGAS. LA CONEXIÓN INDEBIDA PODRÍA CREAR EL
RIESGO DE SER ELECTROCUTADO. EL USO DE TALES ADAPTADORES
NO ESTÁ PERMITIDO EN CANADÁ.
3. Siempre que sea posible, evite el uso de extensiones eléctricas. Si tienen
que usarse, minimice el riesgo de sobrecalentamiento asegurándose de
que sean de catalogación UL y del calibre y la longitud adecuadas. Nunca
use una sola extensión para operar más de un ventilador.
4. No introduzca los dedos ni objetos extraños en el ventilador. No obstruya
ni manipule indebidamente el ventilador mientras est é en operación. No
toque el ventilador mientras esté en operación ni inmediatamente después
de haberlo apagado, ya que ciertas partes podrían estar lo suficientemente
calientes como para causar una lesión.
5. Desenchufe el cordón eléctrico antes de instalar o dar servicio al ventilador.
ADVERTENCIA: NO DEPENDA DEL INTERRUPTOR DE ENCENDIDO Y
APAGADO COMO EL ÚNICO MEDIO PARA INTERRUMPIR LA
ALIMENTACIÓN ELÉCTRICA CUANDO INSTALE O DÉ SERVICIO AL
VENTILADOR. SIEMPRE DESENCHUFE EL CORDÓN ELÉCTRICO.
6. Este ventilador es para uso general EXCLUSIVAMENTE. NO deber á
usarse en localidades potencialmente peligrosas tales como atm ósferas
inflamables, explosivas, cargadas de gases o húmedas.
ADVERTENCIA: PARA REDUCIR EL RIESGO DE INCENDIOS O
DESCARGAS ELÉCTRICAS, NO USE ESTE VENTILADOR CON NINGÚN
DISPOSITIVO DE CONTROL DE VELOCIDAD DE ESTADO SÓLIDO.
7. Asegúrese de que el ventilador esté sobre una superficie estable al estar
en funcionamiento, para evitar toda riesgo de que se voltee.
8. NO utilice el ventilador en una ventana, ya que la lluvia podr ía crear un
peligro eléctrico.
9. Vuelva a armar completamente el ventilador, de acuerdo con las
instrucciones, antes de volver a conectarlo a la alimentación eléctrica
ADVERTENCIA: DEBIDO AL TAMANO Y PESO DE ESTE VENTILADOR,
ASEGURESE DE QUE TODAS LAS PIEZAS ESTAN COMPLETAMENTE
MONTADAS DE ACUERDO CON LAS INSTRUCCIONES. UN FALLO
PODRIA CAUSAR LA DESUNION DE LAS PIEZAS DURANTE SU
FUNCIONAMIENTO Y/O DANOS PERSONALES.
INSTALACIÓN DE MÉNSULA EN PAREDES / TECHOS
NOTA: SIEMPRE INSTALE LA MÉNSULA EN MONTANTES DE 2X4
COMO MÍNIMO.
1. Localice el montante de pared o techo m ás cercano a la ubicaci ón
deseada para el Ventilador. Siguiendo el diagrama de montaje apropiado,
una la Ménsula al montante, usando tres (3) Tornillos de Retraso de 5/16"
de diámetro x 2" de longitud (no proporcionados) o Pernos y Tuercas de
tamaño apropiado si se lo monta a vigas "I".
Conjunto de Montaje en la Pared
(Figura 1)
Conjunto de Montaje en el Techo
(Figura 2)
2. Inserte el Perno a trav és de la Horqueta, Soporte, Orificio de Giro,
Arandela Plana, y dentro de la Tuerca.
(Figura 1)
o
(Figura 2)
3. Mientras sostiene el Ventilador en la posición deseada, apriete firmemente
el perno de 7/16".
Figura 1
(Conjunto de Montaje en la Pared)
Montante de
Techo
Cabeza
de
Ventilador
Perno
Montante
de Pared
Figura 2
(Conjunto de Montaje en la Pared)
Soporte
Soporte
Orificio
de Giro
Orificio
de Giro
Cabeza
de
Ventilador
Perno
Tuerca
Tuerca
New 5/01 3 5084033
Horqueta
Horqueta
Yoke