Simplicity 074025-00 Manual de usuario

Categoría
Compresores de aire
Tipo
Manual de usuario

Este manual también es adecuado para

Read and understand this operator's manual thoroughly before using the product. It contains important
information for your safety as well as operating and maintenance advice.
BRIGGS & STRATTON CORPORATION,
MILWAUKEE, WISCONSIN, U.S.A.
8 GAL PORTABLE
OIL FREE AIR COMPRESSOR
Product Model # 074025-00
Manual # 80018805
Not for Reproduction
BRIGGSandSTRATTON.COM
Thank you for purchasing this quality-built Briggs & Stratton ™ air compressor. We are pleased that
Briggs & Stratton brand. When operated and maintained
according to the instructions in this manual, your Briggs &Stratton air compressor will provide many
years of dependable service.
You can contact Briggs & Stratton Customer Service by phone at (800) 743-4115, or on the
Internet at BRIGGSandSTRATTON.COM.
Date Purchased
2
Not for Reproduction
Thank you for choosing a product from the Briggs & Stratton family of brands. We are honored that you chose
us as your power equipment provider.
WE STRIVE TO CREATE HELPFUL, DEPENDABLE PRODUCTS THAT YOU CAN RELY ON FOR YEARS TO
COME, WHILE COUNTING ON US TO SUPPORT YOU THROUGH THE LIFE OF YOUR PRODUCT.
onlineproductregistration.com or scan the code below from your mobile device.
Product updates
Helpful maintenance and usage tips
Discounts and offers on future products
product online.
Whether you absolutely love your new product or have a suggestion to enhance it, we’d love to hear from you
and value your feedback.
At your service,
David Cluka, Director of Customer Experience
Briggs & Stratton Corporation
CONGRATULATIONS ON YOUR
NEW PRODUCT PURCHASE!
SCAN THIS CODE
to start the registration process on your mobile device
. Data rates apply.
80018805
Not for Reproduction
Table of Contents
Safety Guidelines..................................................................................................................
Product Registration Form....................................................................................................
Assembly Instructions..........................................................................................................
Operating Instructions..........................................................................................................
Technical Specifications........................................................................................................
Care and Maintenance...........................................................................................................
Troubleshooting....................................................................................................................
Exploded View.......................................................................................................................
Parts List...............................................................................................................................
Warranty...............................................................................................................................
Key Parts Diagram.................................................................................................................
4
SAVE THESE INSTRUCTIONS
This manual contains important safety and operating instructions.
Read all instructions and follow them with use of this product.
3
5
7
8
9
Parts Description..................................................................................................................
...........................
9
10
11
12
14
15
16
17
BRIGGSandSTRATTON.COM
Not for Reproduction
Flying Objects
Operator's Manual
Hot Surface
Electrical ShockToxic Fumes
Safety Guidelines
Important Safety Information
Safety Symbols and Meanings
The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard. The warnings
work method, or operating technique that the manufacturer does not specifically recommend, you must satisfy
yourself that it is safe for you and others. You must also make sure that the procedure, work method, or operating
technique that you choose does not render the compressor unsafe.
Warning
Bursting
Hearing
Fire
The safety alert symbol indicates a potential hazard to personal injury. A signal word (DANGER, WARNING, or
CAUTION) is used with the alert symbol to designate a degree or level of hazard seriousness. A safety symbol may
be used to represent the type of hazard. The signal word NOTICE is used to address practices not related to personal
injury.
indicates a hazard which, if not avoided, will result in death or serious injury.
indicates a hazard which, if not avoided, could result in death or serious injury.
indicates a hazard which, if not avoided, could result in minor or moderate injury.
address practices not related to personal injury.
DANGER
WARNING
CAUTION
Notice
5
Not for Reproduction
DO NOT OPERATE THIS UNIT UNTIL YOU READ AND UNDERSTAND THIS
INSTRUCTION MANUAL FOR SAFETY, OPERATION, AND MAINTENANCE
INSTRUCTIONS.
compressor.
Do not restrict compressor ventilation openings or place objects against or on top of compressor. Operate
compressor only in a clean, dry, well ventilated area.
Do not operate unattended. Always turn off and unplug unit when not in use.
High pressure air could result in death or serious injury. Never operate above maximum operating pressure
of the spray gun or tool. Drain water from tank after each use.
Do not weld or repair tank.
Do not spray flammable materials in vicinity of any flame or ignition sources including the compressor unit.
Risk of fire could result in death or serious injury.
Do not operate with pressure switch or safety valve set above maximum allowable working pressure.
Hot compressor surfaces could result in serious injury. Allow compressor to cool before touching.
Inhalation hazard. Using compressor to supply breathing air could result in death or serious injury. Do not
use compressor to supply breathing air.
Risk of serious eye injury. Always wear ANSI Z87.1 approved safety glasses when using air compressor. Do
not spray any part of the body.
Safety Information
6
WARNING
.
Shock risk could result in death or serious injury. Only connect compressor to a properly grounded
receptacle. KEEP CHILDREN AWAY FROM THE AIR COMPRESSOR AT ALL TIMES.
BRIGGSandSTRATTON.COM
Always wear hearing protection when using an air compressor. Failure to do so may result in hearing loss.
Not for Reproduction
Key Parts Diagram
I
A
7
E. Regulated Pressure Gauge
H. Pressure Relief Valve
F. Air Line Outlet
G. Air Tank Ball Valve
D. Air Pressure Regulator
I. ON/OFF Switch B. Air Tank
A. Electric Motor & Air Compressor Pump
L. Wheel
K. Handle
J. Power Cord
M. Air Filter
C. Tank Pressure Gauge
Not for Reproduction
BRIGGSandSTRATTON.COM
A. ELECTRIC MOTOR:
AIR COMPRESSOR PUMP:
B. AIR TANK: The tank is used to store the compressed air.
C. TANK PRESSURE GAUGE:
D. AIR PRESSURE REGULATOR:
WARNING
Never exceed the maximum working pressure of the tool.
E. REGULATED PRESSURE GAUGE: The gauge is used to measure the regulated outlet pressure.
F. AIR LINE OUTLET: The outlet is used to connect air hose with quick connector.
G. AIR TANK BALL VALVE: The ball valve is used to remove moisture from the air tank after the unit is
shut off.
WARNING
Never attempt to open the drain valve when the tank pressure is more than 10 PSI.
8
The motor is used to power the pump. It contains a thermal overload protector. If
the motor overheats for any reason, the thermal overload protector will shut it down in order to prevent
the motor from being damaged.
The pump is used to compress the air and discharge it into the tank via the
piston moving up and down in the cylinder.
The gauge is used to measure the stored air pressure level of the tank. It is
not adjustable by the operator and does not indicate line pressure.
The regulator is used to adjust line pressure to the tool you are using.
Turn the knob clockwise to increase pressure and counterclockwise to decrease pressure.
H. PRESSURE RELIEF VALVE:
I. ON/OFF SWITCH:
J. POWER CORD:
DANGER
Grounded
outlet
Grounding Pin
Plug
Figure 1
The valve is used to prevent system the system. If the pressure reaches the
preset leve motor, it will automatically pop open. You can also pull the ring on the valve to open.
This switch turns on the compressor and is operated manually. When in the ON
position, it allows the operated manually. When in the ON demand. ALWAYS set this switch to OFF
when the compressor is not being used and before unplugging the compressor.
This product is for use on a nominal 120-volt circuit and should be grounded. A cord
with a grounding plug as illustrated must be used. Make sure that the product is connected to an outlet
that has the same configuration as the plug (see Figure 1). No adapter should be used with this
Check with a licensed electrician if the grounding instructions are not
understood or there is doubt as to whether the product is properly
grounded. Do not modify the plug provided. If it will not fit the outlet,
have the proper outlet installed by a licensed electrician.
Improper installation of the grounding plug will result in a risk
of electric shock. If repair or replacement of the cord or plug is
necessary, do not connect the grounding wire to either flat blade
terminal. The grounding wire is in the green outer surface.
Parts Description
Not for Reproduction
9
PREPARATION
Before beginning assembly of product, make sure all parts are present. Compare parts with package
contents list and hardware contents list. If any part is missing or damaged, do not attempt to assemble
the product.
Estimated Assembly Time: 5 minutes
Tools Required for Assembly (not included): 11/16 in. Open Wrench or Adjustable Wrench.
ASSEMBLY INSTRUCTIONS
Hardware Used
1. Removable handle assembly
• Insert handle (K) into the fixed sleeves. Align the tapped holes (K1) with
the holes on the sleeve.
• Fasten the handle to the sleeve using the screws (AA).
1
M6 × 14 Screw
x 2
AA
Hardware Used
2. Wheel assembly
• Insert the bolt (BB) through one of the wheels (L),slide on washer (CC).
• Insert the bolt (BB) through the bracket on the bottom of the tank
assembly. Slide on washer (CC), spring washer (DD) and tighten the nut
(EE). Repeat this step for the second wheel.
• Once assembled, roll the air compressor to test the operation of the
wheels. Periodically check to ensure that wheel and the hardware is secure.
3. Air filter assembly
• Screw the air filter (M) onto the pump.
M10 Bolt
x 2
BB
Ø10 Washer
x 2
CC
Ø10 Spring Washer
x 2
DD
M10 Nut
x 2
EE
K1
3
2
Assembly Instructions
AA
K1
K
Not for Reproduction
BRIGGSandSTRATTON.COM10
BEFORE EACH START UP
1. Set the ON/OFF switch (I) to the O (off) position.
2. Turn the air pressure regulator knob (D) counterclockwise until it stops.
3. Attach air hose/accessories or air tools (not included) to the air line outlet (F).
WARNING! Risk of bursting.
HOW TO START UP
1. Close the air tank ball valve (G) by turning clockwise.
2. Plug in the power cord (J).
3. Set the ON/OFF switch (I) to the I (on) position and allow tank pressure to build. Motor will stop
when tank pressure reaches “cut-out” pressure.
4. Turn the air pressure regulator (D) clockwise until desired pressure is reached.
5. The compressor is ready for use.
WARNING
HOW TO SHUT DOWN
1. Set the ON/OFF switch (I) to the O (off) position.
2. Unplug the power cord (J).
3. Reduce the pressure in the tank through the outlet hose. Pulling the pressure relief valve ring (H) and
keeping it open will also reduce the pressure in the tank.
4. Tip the compressor so the tank drain valve is at the bottom of the tank, then open the tank drain valve
counterclockwise to allow moisture to drain from the tank.
CAUTION!
Escaping air and moisture can propel debr is that may cause eye injury. Wear safety glasses when
opening the drain valve.
WARNING!
To avoid personal injury, always shut off and unplug the unit and relieve all air pressure from the
system before performing any service on the air compressor.
Risk of unsafe operation. Unit cycles automatically when power is on. When performing
maintenance, you may be exposed to voltage sources, compressed air or moving parts. Personal
injuries can occur. Before performing any maintenance or repair, disconnect power source from the
compressor and bleed off all air pressure.
Operating Instructions
Too much air pressure causes a hazardous risk of bursting. Check
the manufacturer’s maximum pressure rating for air tools and accessories. The regulator outlet
pressure must never exceed the maximum pressure rating.
When adjusting from a higher to a lower pressure,
the knob counterclockwise past the desired setting. Then
turn clockwise to reach the desired pressure.
Do not exceed operating pressure of the tool or accessory
being used.
High temperatures are generated by the electric motor
and the pump. To prevent burns or other injuries,
DO NOT touch the compressor while it is running.
Allow it to cool before handling or servicing.
Keep children away from the compressor at all times.
Not for Reproduction
11
WARNING:
To avoid personal injury, always shut off and unplug the unit and relieve all air pressure from the
system before performing.
Regular maintenance will ensure trouble-free operation.
DESCRIPTIONTASK
SERVICE
INTERVAL
Drain the
tank
To prevent corrosion inside the tank, the condensation must be
drained at the end of every workday. Be sure to wear protective
goggles. Relieve the air pressure in the system and then open the
ball valve on the bottom of the tank.
Daily
Check the
relief valve
Pull the relief valve on the ring daily to ensure that it is operating
properly and to clear the valve of any possible obstructions.
Daily
Test for
leakage
Check all connections to see if tight. A small leak of any of part (the
tank, hoses, pipe connections or transfer tubes) will reduce the unit’s
performance. Spray a small amount of soapy water around the area
of the suspected leak with a spray bottle. If bubbles appear, repair or
replace the faulty component. Do not overtighten any connections.
Monthly
Storage
Before storing the unit for a long period, use an air blow gun to clean
all dust and debris from the compressor. Disconnect and coil the
power cord. Pull the pressure relief valve to release all pressure from
the tank. Drain all moisture from the tank. Cover the entire unit to
protect it from moisture and dust.
N/A
Clean the
air filter
A dirty filter will reduce the unit’s performance and life. To avoid any
contamination inside the pump, the filter should be cleaned frequently
and replaced on a regular basis. Foam filter should be cleaned in
warm and soapy water.
Weekly
OPEN
CLOSE
Care and Maintenance
Not for Reproduction
BRIGGSandSTRATTON.COM
12
Troubleshooting
PROBLEM POSSIBLE CAUSE
CORRECTIVE ACTION
There is low
pressure, not
enough air, or the
compressor does
not stop.
1. The tank ball valve is open.
2. There is a leak in the fittings.
3. There is a prolonged or excessive use
of air.
4. The compressor is not large enough.
5. There is a hole in the air hose.
6. The tank leaks.
7. The seals are blown.
8. The valve leaks.
9. There is a leaking or worn piston.
1. Close the ball valve.
2. Check fittings with soapy water. Tighten
or reseal leaking fittings. DO NOT
OVERTINGHTRN.
3. Decrease the amount of air used.
4. Check the air requirement of the
accessory. If it is higher than the CFM and
the pressure supplied by the compressor,
you need a larger compressor. Most
accessories are rated at 25% of the actual
CFM while running continuously.
5. Check and replace if necessary.
WARNING
6. Immediately replace the
tank. DO NOT attempt to repair.
7. Replace the compressor assembly.
8. Replace the compressor assembly.
9. Replace the compressor assembly.
Air leaks from the
regulator or the
regulator does not
regulate air
pressure.
1. The internal parts of the
regulator are dirty or
damaged.
1. Replace the regulator or
internal parts.
The regulated
pressure gauge
reading drops
when the air
accessory is
being used.
1. This is normal.
2. The compressor is not
large enough.
1. If the pressure drops too low, adjust the
regulartor while the accessory is used.
2. Check the air requirement of the
accessory. If it is higher than the CFM and
the pressure supplied by the compressure
supplied by the compressor, you need a
larger compressor. Most accessories are
rated at 25% of the actual CFM while
running continuously.
The pressure
relief valve
opens.
1. The tank pressure exceeds the normal
rating pressure.
2. The pressure switch is stuck.
1. Replace the pressure switch.
2. Replace the pressure switch.
Not for Reproduction
13
Troubleshooting
PROBLEM POSSIBLE CAUSE
CORRECTIVE ACTION
The motor will not
run.
1. Tank pressure exceeds the preset
pressure switch limit.
2. The fuse is blown or the circuit breaker
tripped.
3. The check valve is stuck in the open
position.
4. The wire gauge in the cord is wrong or
the extension cord length is excessive.
5. There are loose electrical connections.
6. The motor’s thermal overload protection
has tripped.
7. The motor, capacitor or safety valve is
defective.
1. The motor will start automatically when
the tank pressure drops below the tank
cut-in pressure.
2. Replace the blown fuse or reset the
circuit breaker. Do not use a fuse or circuit
breaker with a higher rating than specified
for your branch circuit. Check for proper
fuse; type T fuse is acceptable. Check for
low voltage and proper extension cord size.
Disconnect other applications from the
circuit. Operate the compressor on a
dedicated circuit.
3. Remove and clean or replace.
4. Check for proper gauge and extension
cord length.
5. Contact an authorized service center.
6. Turn the air compressor off, unplug the
power cord and wait until the motor has
cooled down. Plug in the power cord only
after the motor has cooled down, waiting at
least five minutes to make sure the thermal
overload protector has recovered.
7. Have the compressor serviced by a
qualified technician.
Not for Reproduction
BRIGGSandSTRATTON.COM14
Briggs & Stratton Air Compressor Warranty Policy
This Limited warranty does not include the following:
LIMITED WARRANTY
A. Parts that are worn or broken or which have become inoperative due to abuse, misuse, accidental damage, neglect or lack of
proper installation, operation or maintenance (as outlined in the applicable owner’s manual or operating instructions) or product
that has been used for industrial, professional, commercial or rental purposes;
B. Normal wear and tear or expendable parts or accessories that may be supplied with the product which are expected to become
inoperative or unusable after a reasonable period of use;
C. Routine maintenance and consumable items such as, but not limited to fuel, lubricants, valves, belts, knobs, nuts, fluids,
tune-ups, or adjustments;
D. Damage caused by repairs made or attempted by persons not authorized by the manufacturer;
E. Product that was sold to the original purchaser as reconditioned or refurbished product (unless otherwise specified in writing);
F. Product or parts thereof if any part from another manufacturer has been installed or any repairs or alterations have been made
or attempted by unauthorized persons;
G. Normal deterioration of the exterior finish such as, but not limited to, scratches, dents, paint chips, nor any corrosion or
discoloring by heat, abrasive and chemical cleaners;
H. Component parts sold by and identified as the product of another company, which shall be covered under the other product
manufacturer’s warranty, if any.
October, 2015
These are our standard warranty terms, but occasionally there may be additional warranty coverage that was not determined at
time of publication. For a listing of current warranty terms for your air compressor, go to BRIGGSandSTRATTON.COM
BRIGGS & STRATTON is a trademark of BRIGGS & STRATTON CORPORATION and is used under license to Alton Industry
Co. Ltd®. Alton Industry Co. Ltd warrants this Briggs & Stratton brand product for a period of one year from the date of
original retail purchase against defects in materials and workmanship. Subject to the conditions and limitations described
below, if Alton Industry Co. Ltd determines this product is covered under this warranty, it will be replaced with the same
model or one of equal value or specification, at Alton Industry Co. Ltd’s option. Alton Industry Co. Ltd will bear the cost of
replacement. The purchaser must contact Alton Industry Co. Ltd® for all warranty authorizations.
There is no other express warranty. Implied warranties, including those of merchantability and fitness for a particular
purpose, are limited to one year, or to the extent permitted by law. Liability for incidental or consequential damages are
excluded to the extent exclusion is permitted by law. Some states or countries do not allow limitations on how long an
implied warrant lasts, and some states of countries do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation and exclusion may not apply to you. This warranty gives you specific legal rights and you
may also have other rights which vary from state to state or country to country.
Save your proof of purchase receipt. If you do not provide proof of the initial purchase date at the time warranty service is
requested, the manufacturing date of the product will be used to determine the warranty period. Product registration is not
required to obtain warranty service on Briggs & Stratton products.
TM
TM
For questions about our warranty on this product, contact us at:
Alton Industry LTD. Group
1031 North Raddant Road
Batavia Illinois 60510
888-899-0146
info@altonindustries.com
www.altonindustries.com
Not for Reproduction
15
Model No.
Pump
Motor
Voltage/Amps/HZ
Cut-in Pressure
Air Tank Capacity
Cut-out Pressure
CFM @ 40 PSI
CFM @ 90 PSI
Power Cord
Oil free, Direct drive, Single stage
074025-00 / 0300841
1.5 HP
120/12/60
8 Gallon
120 PSI
150 PSI
4.8
3.7
SJT 16 AWG / 72 in. Length
NOTE: Avoid use of extension cords. If use of an extension cord cannot be avoided, the cord should be a minimum
wire size of 12 AWG and no longer than 30 feet. Use only a 3-wire extension cord that has a 3-blade grounding plug
and a 3-slot receptacle that will accept the plug on the product.
Product Specifications
*CFM: Cubic Feet per Minute.
This compressor is rated in accordance with ISO 1217, displacement compressors acceptance
tests.
*
*
Not for Reproduction
BRIGGSandSTRATTON.COM
16
Exploded View
Not for Reproduction
17
PART DESCRIPTION QTY PART DESCRIPTION QTY
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
Rubber foot
Bolt M10 X 20
Anchor nut
Power cord
Thumbscrew
Check valve
Quick coupler
Regulator
Relief valve
Handle
Pressure gauge
Front shroud
Switch retainer
On/Off switch
Run capacitor,50
μf
Start capacitor,200 μf
Eblow
Pump/Motor assembly
Fan
2
2
1
1
2
1
1
1
1
1
2
1
1
1
1
1
1
1
1
Air filter
Back shroud
Bolt M8 X 25
Tranfer tube
Washer Ø8
Cushion pad
Pressure switch
Bolt M5×10
Lock washer
Wheel
Shoulder bolt
Washer Ø10
Spring washer Ø10
Nut M10
Air tank
Ball valve
1
1
4
4
4
1
4
4
1
2
2
2
2
4
2
4
1
1
Parts List
Bolt M5 X 12
Self-tapping screw ST3.9 X16F
Not for Reproduction
Producto # 074025-00
Manual # 80018805
Not for Reproduction
Donde estamos
ABRIGGSandSTR TTON.COM
2
TM
Not for Reproduction
Gracias por elegir un producto de la familia de marcas Briggs & Stratton usted. Nos sentimos honrados de que
nos haya elegido como su proveedor de equipos de energía.
El registro de su producto es el primer paso para recibir la mejor experiencia post-venta. Para empezar, vaya a
onlineproductregistration.com o escanear el código de abajo desde su dispositivo móvil.
NOS ESFORZAMOS POR CREAR PRODUCTOS CONFIABLES, ÚTILES QUE USTED PUEDE CONFIAR EN
LOS AÑOS VENIDEROS, MIENTRAS COUNTIIMG EN EEUU PARA APOYAR A TRAVÉS LA VIDA DE SU
PRODUCTO.
Actualizaciones de Producto
Consejos de mantenimiento y uso votos
Descuentos y ofertas en productos futuros
Si a pesar de todo el amor de su nuevo producto o tiene alguna sugerencia para mejorarla, nos encantaría saber
de usted y valoramos sus comentarios.
Después de registrarse, usted recibirá un correo electrónico de confirmación que incluye una invitación a
calificar y comentar sobre su nuevo producto en línea.
La confirmación de la garantía de la elegibilidad de cobertura
Partes más eficientes y apoyo de servicio
A su servicio,
CONGRATULATIONS ON VOUR
NEW PRODUCT PURCHASE!
LEA ESTE CÓDIGO
para iniciar el proceso de registro en el dispositivo móvil. Se aplican tarifas
de datos.
David Cluka, Director de Experiencia del Cliente
Briggs & Stratton Corporación
80018805
Not for Reproduction
................................................................................................
..........................................................................
.........................................................................................
...........................................................................................................................
...................................................................................
..............................................................................................
.......................................................................................
................................................................................................................
...............................................................................................................
..................................................................................................
...............................................................................................
4
GUARDE ESTAS INSTRUCCIONES
Este manual contiene instrucciones operativas y seguridad importante.
Lea todas las instrucciones y seguirlas con el uso de este producto.
BRIGGSandSTRATTON.COM
............................................................................................
Índice
ClAVE DIAGRAMA DE PIEZAS
16
14
15
17
8
DESCRIPCIÓN DE LAS PARTES
Not for Reproduction
El vuelo se opone
Manual del operador
Superficie caliente
Choque eléctricoVapores toxicos
Directrices de seguridad
Información importante de seguridad
Símbolos de seguridad y significados
El fabricante no puede anticipar todas las posibles circunstancias que puedan implicar un riesgo. Las advertencias
de este manual y las etiquetas y calcomanías adheridas a la unidad, por lo tanto, no todos los servicios incluidos.
Si utiliza un procedimiento, método de trabajo o técnica de operación que el fabricante no recomienda específicamente,
debe satisfacer a ti mismo de que es seguro para usted y los demás. También debe asegurarse de que el procedimiento,
método de trabajo o técnica de operación que elija no haga al compresor inseguro.
Advertencia
Muy llenoFuego
El símbolo de alerta de seguridad indica un riesgo potencial de lesiones personales. Una palabra (PELIGRO,
ADVERTENCIA o PRECAUCIÓN) se utiliza con el símbolo de alerta para designar un grado o nivel de gravedad del
riesgo. Un símbolo de seguridad puede ser usado para representar el tipo de peligro. La palabra de señalización
AVISO \ s utilizado para prácticas de dirección no relacionados con lesiones personales.
indica un peligro que, si no se evita, provocará la muerte o lesiones graves.
indica un peligro que, si no se evita, vaca / t / resultado en la muerte o lesiones graves.
indica un peligro que, si no se evita, podría causar lesiones leves o moderadas.
prácticas de dirección no relacionados con lesiones personales.
PELIGRO
ADVERTENCIA
PRECAUCIÓN
aviso
5
Audición
Not for Reproduction
No opere esta unidad hasta que haya leído y entendido este MANUAL DE
INSTRUCCIONES PARA LAS INSTRUCCIONES DE SEGURIDAD, operación y
mantenimiento.
Información de seguridad
6
ADVERTENCIA
BRIGGSandSTRATTON.COM
Riesgo de incendio causado por chispas del motor y el interruptor de presión podría ocasionar la muerte o
lesiones graves. No haga funcionar el compresor cerca de gas o vapor inflamable. Nunca almacene líquidos
o gases inflamables en * proximidades de compresor.
Superficies compresores calientes podrían causar lesiones graves. Permita que el compresor se enfríe
antes de tocarlo.
Peligro de inhalación. El uso del compresor para suministrar aire respirable puede causar la muerte o lesiones
graves. No hay compresor de uso para suministrar aire respirable.
Riesgo de lesiones oculares graves. Siempre use ANSI Z87.1 gafas de protección cuando se utiliza el compresor
de aire. No rocíe cualquier parte del cuerpo.
Riesgo de choque podría causar la muerte o lesiones graves. Sólo conecte el compresor a un receptáculo
de tierra. MANTENGA A LOS NIÑOS LEJOS DEL COMPRESOR DE AIRE EN TODO MOMENTO.
Siempre use protección para los oídos cuando se utiliza un compresor de aire. El no hacerlo puede resultar en
la pérdida de la audición.
De aire de alta presión podría causar la muerte o lesiones graves. Nunca opere por encima de la presión
máxima de funcionamiento de la pistola o herramienta. Drene el agua del tanque después de cada uso.
No opere con interruptor de presión o válvula de seguridad establecido por encima de la presión máxima
de trabajo permitida.
No soldar o tanque reparación.
No restrinja los orificios de ventilación del compresor o colocar objetos en contra o en la parte superior del
compresor. Opere el compresor sólo en un área limpia, seca y bien ventilada.
No ponga en funcionamiento sin vigilancia. Siempre apague y desenchufe la unidad cuando no esté en uso.
No rocíe materiales inflamables en las proximidades de nada con fuego o de ignición, incluyendo el compresor.
Riesgo de incendio podría causar la muerte o lesiones graves.
Not for Reproduction
7
Clave Diagrama De Piezas
E. Indicador de presión regulado
H. Válvula de bola de presión
F. Salida de la línea de aire
G. Válvula de bolaABRIR del tanque de aire
D. Regulador de presión de aire
I. Interruptor de ENCENDIDO/APAGADOB. Tanque de aire
A. Motor eléctrico y bomba compresor de aire
L. Rueda
K. Manija
J. Cable de alimentación
M. Filtro de aire
C. Indicador de presión del tanque
Not for Reproduction
BRIGGSandSTRATTON.COM
8
Descripción De Las Partes
La salida se utiliza para conectar la manguera de aire con el conector
rápido.
Not for Reproduction
9
1
AA
AA
K
K1
3
BB
M
Instrucciones De Ensamblaje
Not for Reproduction
Instruccions De Funcionamiento
BRIGGSandSTRATTON.COM10
H
ABIERTO CERCA
APAGADO
EN
Not for Reproduction
BRIGGSandSTRATTON.COM
10
G
D
H
Not for Reproduction
Cuidado Y Mantenimiento
Not for Reproduction
BRIGGSandSTRATTON.COM
12
Solución De Problemas
Not for Reproduction
13
Solución De Problemas
Not for Reproduction
BRIGGSandSTRATTON.COM14
Briggs & Stratton Política de garantía del compresor de aire
Octubre, 2015
Estos son nuestros términos de garantía estándar, pero en ocasiones puede haber cobertura de la garantía adicional que no fue
determinado en el momento de su publicación. Para obtener una lista de los términos de garantía actuales para su compresor
de aire, vaya a BRIGGSandSTRATTON.COM
TM
Para preguntas acerca de nuestra garantía sobre este producto, póngase en contacto con nosotros en:
Alton Industria LTD. Grupo 1031 Norte Raddant Road
Batavia Illinois 60510
888-899-0146
info@altonindustries.com
www.altonindustries.com
Not for Reproduction
15
Transmisión directa sin aceite,De una fase
074025-00 / 0300841
1,5 HP
120/12/60
30,28 Iitros
120 PSI
150 PSI
0,14
0,1
SJT 16 AWG /1,83 m de largo
Especificaciones Del Producto
Este compresor tiene una clasificación de acuerdo con la norma IOS 1217,desplazamiento Compresores
pruebas de aceptación .
Not for Reproduction
BRIGGSandSTRATTON.COM
16
Vista Detallada
Not for Reproduction
17
Lista Da Piezas
Not for Reproduction
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35

Simplicity 074025-00 Manual de usuario

Categoría
Compresores de aire
Tipo
Manual de usuario
Este manual también es adecuado para

en otros idiomas