Kichler Lighting 42496NI Manual de usuario

Tipo
Manual de usuario

Este manual también es adecuado para

IS-42496-US
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
6) Adjust chain to desired length at this me and aach
chain[A] to decorave loops by opening one chain
link, close the open links by wrapping with a towel and
squeezing closed using pliers.
7) Weave electrical wire and ground wire through chain
links no more than 3 inches apart and run into the
canopy.
8) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a
hole and two raised dimples, wrap ground wire from
outlet box around green ground screw, and thread
into hole.
b) On xtures where a cupped washer is provided,
aach ground wire from outlet box under cupped
washer and green ground screw, and thread into
mounng strap.
If xture is provided with ground wire, connect xture
ground wire to outlet box ground wire with wire
connector (Not provided) aer following the above steps.
Never connect ground wire to black or white power
supply wires.
9) Make wire connecon. Reference chart below for correct
connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth (See illus.)
Neutral Wire
10) Raise canopy to ceiling. Note: Be certain wires do not
get pinched between the canopy and ceiling.
11) Use knobs[J] and lockwashers[K] to secure canopy.
Tighten to secure.
12) Insert recommended bulbs (Not supplied).
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Fixture Diagram
Parts List
[A] Chain
[B] Decorative
Loop
[C] Main Body
[D] Canopy
[E] Lockwasher
[F] Hexnut
[G] Mounting
Strap
[H] Mounting
Screws
[I] Outlet Box
[J] Knobs
[K] Lockwashers
[L] Strap
Mounting
Screws
[M] Metal Trim
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance
with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.
Installaon Instrucons
1) Find the appropriate threaded holes on mounng
strap[G]. Assemble mounng screws[H] into threaded
holes.
2) Aach mounng strap to outlet box[I] using the supplied
strap mounng screws[L]. The mounng strap can be
adjusted to suit posion of xture.
3) Place the metal trim[M] on top of the main body[C].
4) Aach one decorave loop[B] to xture.
5) Aach the other decorave loop[B] to the canopy[D]
using the lockwasher[E] and the hexnut[F].
I
G
L
E
F
H
D
K
J
B
A
B
C
M
IS-42496-US
Estamos aquí para ayudarle 866-558-5706
Horario: Lunes-Viernes 9am a 5pm EST (hora ocial del este)
4) Fije un anillo decoravo [B] al artefacto [C].
5) Fije el otro anillo decoravo [B] al escudete [D] usando
la arandela de seguridad [E] y la tuerca hexagonal [F].
6) Ajuste la cadena a la longitud deseada en este momento
y sujete la cadena [A] a los anillos decoravos abriendo
un eslabón de la cadena; cierre los eslabones abiertos
envolviéndolos con un paño y apretándolos con una
pinza.
7) Entrelace el cable eléctrico y el cable de erra a través de
los eslabones de la cadena [H] a no más de 3 pulgadas de
distancia y hacia el escudete.
8) Instrucciones de conexión a erra solamente para los
Estados Unidos. (Vea la ilustracion a o b).
a) En las lámparas que enen el eje, de montaje con un
agujero y dos hoyuelos realzados, enrollar el alambre
a erra de la caja tomacorriente alrededor del tornillo
verde y pasarlo por el aquiero.
b) En las lámparas con una arandela acopada, jar el
alambre a erra de la caja tomacorriente del ajo de la
arandela acoada y tornillo verde, y paser por el eje
de montaje.
Si la lámpara viene con alambre a erra, conecter el
alambre a erra de la lámpara al alambre a erra de la
caja tomacorriente con un conector de alambres (No
incluido) espués de seguir los pasos anteriores. Nunca
conectar el alambra a erra a los alambres eléctros negro
o blanco.
9) Haga les conexiones de los alambres. La tabla de
referencia de abajo indica las conexiones correctas y los
alambres correspondientes.
Conectar el alambre de
suministro negro o rojo al
Conectar el alambre de
suministro blanco al
Negro Blanco
*Cordon paralelo (redondo
y liso)
*Cordon paralelo (cuadrado
y estriado)
Claro, marrón, amarillio
o negro sin hebra
idencadora
Claro, marrón, amarillio
o negro con hebra
idencadora
Alambre aislado (diferente
del verde) con conductor
de cobre
Alambre aislado (diferente
del verde) con conductor
de plata
*Nota: Cuando se uliza alambre
paralelo (SPT 1 y SPT 2). El alambre
neutro es de forma cuadrada o
estriada y el otro alambre será
de forma redonda o lisa. (Vea la
ilustracíón).
Hilo Neutral
10) Suba el escudete al cielorraso. NOTA: Asegúrese de que
los cables no queden apretados entre el escudete y el
cielorraso.
11) Use las perillas [J] y las arandelas de seguridad [K] para
asegurar el escudete. Ajuste para asegurar.
12) Inserte las bombillas recomendadas (No se proveen).
ARANDELA
CONCAVA
TIERRA DE LA
CAJA DE SALIDA
TORNILLO DE TIERRA,
VERDE
DEPRESIONES
TIERRA
ARTEFACTO
CONECTOR DE ALAMBRE
TIERRA DE LA
CAJA DE SALIDA
TORNILLO DE TIERRA,
VERDE
TIERRA
ARTEFACTO
a
b
Diagrama de Accesorios
Lista de Partes
[A] La Cadena
[B] Anillo
Decorativo
[C] Artefacto
[D] Escudete
[E] La Arandela de
Seguridad
[F] La Tuerca
Hexagonal
[G] Abrazadera de
Montaje
[H] Los Tornillos
de Montaje
[I] Caja de
Distribución
Eléctrica
[J] Las Perillas
[K] LasAarandelas
de Seguridad
Precauciones
PRECAUCIÓN – RIESGO DE DESCARGA ELÉCTRICA –
Desconecte la electricidad en el panel principal del
interruptor automáco o caja principal de fusibles antes de
comenzar y durante la instalación.
ADVERTENCIA:
Este accesorio está desnado a la instalación de
acuerdo con el Naonal Electrical Code (NEC) y todas las
especicaciones del código local. Si no está familiarizado
con los requisitos del código, la instalación se recomienda
un electricista cercado.
Instrucciones de Instalación
CADENA COLGADA
1) Encuentre los oricios roscados adecuados en la
abrazadera de montaje [G]. Fije los tornillos de montaje
[H] en los oricios roscados.
2) Fije la abrazadera de montaje a la caja de distribución
eléctrica [I] ulizando los tornillos de montaje [L]
suministrados. La abrazadera de montaje se puede
ajustar para adaptarse a la posición del artefacto.
3) Coloque la moldura metálica [M] en la parte superior del
cuerpo principal [C].
I
G
L
E
F
H
D
K
J
B
A
B
C
M
IS-42496-CB
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
6) Adjust chain to desired length at this me and aach
chain[A] to decorave loops by opening one chain
link, close the open links by wrapping with a towel and
squeezing closed using pliers.
7) Weave electrical wire and ground wire through chain
links no more than 3 inches apart and run into the
canopy.
8) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a
hole and two raised dimples, wrap ground wire from
outlet box around green ground screw, and thread
into hole.
b) On xtures where a cupped washer is provided,
aach ground wire from outlet box under cupped
washer and green ground screw, and thread into
mounng strap.
If xture is provided with ground wire, connect xture
ground wire to outlet box ground wire with wire
connector (Not provided) aer following the above steps.
Never connect ground wire to black or white power
supply wires.
9) Make wire connecon. Reference chart below for correct
connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth (See illus.)
Neutral Wire
10) Raise canopy to ceiling. Note: Be certain wires do not
get pinched between the canopy and ceiling.
11) Use knobs[J] and lockwashers[K] to secure canopy.
Tighten to secure.
12) Insert recommended bulbs (Not supplied).
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Fixture Diagram
Parts List
[A] Chain
[B] Decorative
Loop
[C] Main Body
[D] Canopy
[E] Lockwasher
[F] Hexnut
[G] Mounting
Strap
[H] Mounting
Screws
[I] Outlet Box
[J] Knobs
[K] Lockwashers
[L] Strap
Mounting
Screws
[M] Metal Trim
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance
with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.
Installaon Instrucons
1) Find the appropriate threaded holes on mounng
strap[G]. Assemble mounng screws[H] into threaded
holes.
2) Aach mounng strap to outlet box[I] using the supplied
strap mounng screws[L]. The mounng strap can be
adjusted to suit posion of xture.
3) Place the metal trim[M] on top of the main body[C].
4) Aach one decorave loop[B] to xture.
5) Aach the other decorave loop[B] to the canopy[D]
using the lockwasher[E] and the hexnut[F].
I
G
L
E
F
H
D
K
J
B
A
B
C
M
IS-42496-CB
Nous sommes là pour vous aider 866-558-5706
Heures : du lundi au vendredi, de 9h à 17h (heure de l’Est)
INSTRUCTIONS:
For Assembling and Installing Fixtures in Canada
Pour Lassemblage et L’installaon Au Canada
SUSPENDU AVEC CHAÎNE :
1) Localisez les trous letés appropriés sur l’étrier de
montage [G]. Vissez les vis de montage [H] dans les
trous letés.
2) Fixez le support de montage sur la boîte à prises [I] avec
les vis de xaon du support [l] (fournies). Le support de
montage peut être réglé en foncon de la posion du
luminaire.
3) Placez la garniture métallique [M] sur le corps principal
[C].
4) Fixez une boucle décorave [B] à la xaon [C].
5) Aachez l’autre boucle décorave [B] au cache [D] à
laide de la rondelle d’arrêt [E] et de lécrou hexagonal
[F].
6) Ajustez la chaîne à la longueur souhaitée et aachez
la chaîne [A] aux boucles décoraves en ouvrant un
maillon de la chaîne, fermez les maillons ouverts en les
enveloppant avec une serviee et en les serrant à l’aide
dune pince.
7) Passez d’abord le l électrique et le l de terre dun
maillon à l’autre de la chaîne [H] avec un intervalle
maximal de 7,50 cm entre et acheminez ensuite dans le
couvercle.
8) Connecter les ls. Se reporter au tableau ci-dessous pour
faire les connexions.
Connecter le l noir ou
rouge de la boite
Connecter le l blanc de
la boîte
A Noir A Blanc
*Au cordon parallèle (rond
et lisse)
*Au cordon parallèle (à
angles droits el strié)
Au transparent, doré,
marron, ou noir sans l
disncf
Au transparent, doré,
marron, ou noir avec un l
disncf
Fil isolé (sauf l vert) avec
conducteur en cuivre
Fil isolé (sauf l vert) avec
conducteur en argent
*Remarque: Avec emploi d’un
l paralléle (SPT 1 et SPT 2). Le
l neutre est á angles droits ou
strié et lautre l doit étre rond
ou lisse (Voir le schéma).
Fil Neutre
9) Soulevez le cache jusqu’au plafond. REMARQUE :
Assurez-vous que certains ls ne sont pas coincés entre
le cache et le plafond.
10) Ulisez les boutons [J] et les rondelles [K] pour sécuriser
le couvert. Serrez pour xer.
11) Installez la ou les ampoules recommandées (non
fournies).
Diagramme d’appareils
ATTENTION – RISQUE DE DÉCHARGES ÉLECTRIQUES -
Couper le courant au niveau du panneau du disjoncteur du
circuit principal ou de la boîte à fusibles principale avant de
procéder à l’installaon.
ATTENTION:
Ce luminaire doit être installé conformément aux codes
d’électricité naonaux (NEC) et sasfaire toutes les
spécicaons des codes locaux. Si vous ne connaissez pas
les exigences de ces codes, il est recommandé de coner
l’installaon à un électricien ceré.
Liste des Pièces
Précauons
[A] La chaîne
[B] Boucle
décorave
[C] La xaon
[D] Cache
[E] Rondelle
d’arrêt
[F] Bague Filetée
[G] Vis
[H] Chaîne
[I] la boîte à
prises
[J] Les boutons
[K] Les rondelles
Instrucons d’installaon
I
G
L
E
F
H
D
K
J
B
A
B
C
M
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Kichler Lighting 42496NI Manual de usuario

Tipo
Manual de usuario
Este manual también es adecuado para