ADA HIGH VOLTAGE WIRING INSTRUCTIONS FOR SINGLE BLOWER RANGE HOODS WITH
PUSH-BUTTON CONTROL
ACCESS TO RANGE HOOD CONTROL PANEL CONNECTIONS
Remove filters from the hood and set them aside.
NOTE: Some models have only one filter.
Remove the wiring cover (shaded part on illustration below)
retaining screw. Slide out the wiring cover from the hood and set
it aside with its screw.
Unplug the blower connector from the main harness.
NOTE: The illustrations in this procedure are generic; some hood details may slightly differ from the hood you have on hand but the
procedure itself applies to all single blower range hoods listed in this document (see page 3).
Wiring cover
screw
Using a 11/32'' socket, remove the 6 nuts retaining the blower
chamber to the hood assembly (2 nuts on inner back and 2 other
nuts per sides), then use a Phillips no. 2 screwdriver to remove
both front corner screws. See picture below for nuts and screws
locations. Pull out the blower chamber from the hood assembly
and set it aside with its retaining screws and nuts.
HE0253
HD0672
Nuts
Nuts
Screw
Remove and set aside the 4 front screws retaining the bent plate
to the hood.
HD0673
Screw locations
Fold back the bent plate to access to control panel connections.
HD0674
1
99045860A
WARNING
!
For residential (domestic) installation only. Before proceeding, switch power off at service panel and lock service
disconnecting means to prevent power from being switched on accidentally. Installation work and electrical wiring
must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated
construction codes and standards. Also, it is recommended to wear safety glasses and gloves.
120 VAC POWER CABLE ENTERING THE HOOD
According to your needs, there are 2 ways to wire a 2-rocker switch control to these range hoods: 120 VAC power cable entering the range
hood or 120 VAC power cable entering the switch box.
TO HOOD
2-ROCKER
SWITCH
WHITE
GROUND
HE0265A
14/3
RED
(Light override)
BLACK
(Master ON/OFF)
TO CONTROL PANEL
MOTOR
GROUND
WIRE
14/3 CABLE
120 VAC
HOUSE WIRING
RED
BLACK
WHITE
GROUND
1
2
3
4
5
Install a 2-rocker switch at a convenient place for the user.
Use a 14/3 cable to wire it to the range hood (see diagram
at right).
NOTE: Code requires both ends of WHITE wire insulation
to be colored; use a permanent marker.
Insert the 14/3 cable along with the 14/2 house wiring cable in the
hood through an UL approved wire clamp, suitable for 2 cables.
Add a GROUND wire and connect one end to the GREEN ground
screw. Use an appropriate wire nut to connect the other end of the
added GROUND wire with the ground wire coming from the 14/3
cable and the ground wire coming from 14/2 house wiring cable.
Connect BLACK wire from house wiring to WHITE wire from
14/3 cable using an appropriate wire nut.
Connect BLACK wire from 14/3 cable to BLACK wire from range
hood wiring using an appropriate wire nut.
Connect WHITE wire from house wiring to WHITE wire range
hood wiring using an appropriate wire nut.
Run RED wire from 14/3 cable through bend plate wiring opening
for hood control connection. See next page for RED wire
connection.
120 VAC POWER CABLE ENTERING THE SWITCH
GROUND
WHITE
WHITE
120 VAC
LINE IN
TO HOOD
14/3 CABLE
BLACK
2-ROCKER
SWITCH
RED
(Light override)
BLACK
(Master ON/OFF)
TO CONTROL PANEL
MOTOR
GROUND
WIRE
14/3 CABLE
RED
BLACK
WHITE
GROUND
1
2
3
4
Install a 2-rocker switch at a convenient place for the user.
Feed the switch box with 120 VAC house wiring and use
a 14/3 cable to wire it to the range hood (see diagram at
right).
Insert the 14/3 cable in the hood through an UL approved wire
clamp. Connect ground wire to the GREEN ground screw.
Connect WHITE wire from 14/3 cable to WHITE wire from range
hood wiring using an appropriate wire nut.
Connect BLACK wire from 14/3 cable to BLACK wire from range
hood wiring using an appropriate wire nut.
Run RED wire from 14/3 cable through bend plate wiring opening for
hood control connection. See next page for RED wire connection.
Light
override
Master
ON/OFF
2
CAUTION
Use standard switches that are rated 120 VCA, 15 A. Only use wires suitable for at least 90C (194F). Ensure the
wires are reliably routed away from the halogen lights (if present).
NOTE: Allow enough length of 14/3 cable to perform the RED wire
connection in the hood nose.
NOTE: Allow enough length of 14/3 cable to perform the RED wire
connection in the hood nose.
Light
override
Master
ON/OFF
BLUE WIRE
RED WIRE
FROM 14/3 CABLE
A
B
A Cut the BLUE wire of the push button control harness.
B Connect the RED wire from 14/3 cable to both ends of the BLUE wire, using an appropriate
wire nut.
RED WIRE CONNECTION
Once all the connections are done, finalize the installation by reversing steps to on first page.
NOTE: Be careful while reinstalling wiring cover to the hood.
CAUTION
Ensure both tabs on inner top of hood are engaged in their corresponding slots in wiring cover. Also, take care not
to pinch wires while reinstalling wiring cover.
SCREW
TABS ON INNER
TOP OF HOOD
ENGAGED IN
WIRING COVER
SLOTS.
3
Broan Series: BCSM, BKSM, CKSL and CRDE
NuTone Series: NRSL
Venmar Bistro Series: VBNDE
NOTES: 1. The push-button controls may have 6 wires OR 5 wires connected to the control board; the procedure below applies to both
push-button control models since these 2 models have only one BLUE wire.
2. To ease access to wires, disconnect the harness from the control board before performing steps
A and B.
THIS PROCEDURE APPLIES TO THE FOLLOWING RANGE HOOD SERIES
INSTRUCTIONS DE CÂBLAGE HAUTE TENSION ENTRE LES HOTTES À VENTILATEUR SIMPLE
À BOUTONS-POUSSOIRS ET UNE COMMANDE MURALE
AVERTISSEMENT
!
Uniquement pour une installation résidentielle (domestique). Avant de commencer, coupez le courant au panneau
d’alimentation et verrouillez-en l’accès afin d’éviter sa remise en marche accidentelle. Les travaux d’installation
et de raccordement électrique doivent être effectués par une personne qualifiée, conformément aux codes et aux
standards de construction, incluant ceux concernant la protection contre les incendies. Aussi, il est recommandé
de porter des lunettes et des gants de sécurité.
ACCÈS AUX CONNEXIONS DU PANNEAU DE COMMANDE
Retirer les deux filtres de la hotte et les mettre de côté.
NOTE : Certains modèles n’ont qu’un seul filtre.
Retirer la vis de retenue du couvercle du compartiment électrique
(en gris dans l’illustration ci-dessous). Glisser le couvercle hors
de la hotte et le mettre de côté avec sa vis.
Débrancher le connecteur du ventilateur du faisceau électrique
principal.
À l’aide d’une douille de 11/32 po, retirer les 6 écrous retenant
le caisson du ventilateur à la hotte (2 écrous au dos intérieur de
la hotte et 2 autres écrous par côtés), puis utiliser un tournevis
Phillips n° 2 pour retirer les 2 vis des coins avant. Voir la photo
de droite pour l’emplacement des écrous et des vis. Soulever
hors de la hotte le caisson du ventilateur et le mettre de côté
avec ses vis et écrous.
HE0253
HD0672
Écrous
Écrous
Vis
Retirer et mettre de côté les 4 vis avant retenant la plaque pliée à
la hotte.
HD0673
Emplacement des vis
Plier vers l’arrière la plaque pliée afin d’accéder au dessous du
panneau de contrôle.
HD0674
4
NOTE : Les illustrations de cette procédure sont génériques; certains détails de hotte peuvent différer légèrement de ceux qui sont sur
la hotte que vous avez en main, cependant cette procédure s'applique sur toutes les hottes à ventilateur simple citées dans ce
document (voir page 6).
Vis du
couvercle du
compartiment
électrique
Selon vos besoins, il existe 2 façons de raccorder un interrupteur double à ces hottes : lorsque le câble électrique de 120 VCA alimente la
hotte ou lorsque le câble électrique de 120 VCA alimente l’interrupteur double.
5
ATTENTION
Utiliser des interrupteurs standards d’une capacité de 120 VCA, 15 A. Utilisez des fils pouvant supporter une
température d’au moins 90C (194F). S’assurer que les fils sont placés loin des ampoules halogènes (si présentes).
CÂBLE ÉLECTRIQUE DE 120 VCA
ALIMENTANT LA HOTTE
VERS LA HOTTE
BLANC
MISE À
LA TERR
HE0265F
CÂBLE 14/3
ROUGE
(Éclairage
prioritaire)
NOIR
(Principal
marche/arrêt)
INTERRUPTEUR
DOUBLE
VERS LA COMMANDE
DE LA HOTTE
FIL DE MISE À LA TERRE
DU MOTEUR
CÂBLE 14/3
ALIMENTATION
DOMESTIQUE
120 VCA
ROUGE
NOIR
BLANC
MISE À
LA TERR
E
1
2
3
4
5
Installer un interrupteur double à un emplacement
pratique pour l’utilisateur. Utiliser un câble 14/3 pour
le raccorder à la hotte (voir le diagramme de droite).
NOTE : Le code exige de colorer les deux extrémités
de la gaine du fil BLANC; utiliser un marqueur
permanent.
Insérer le câble 14/3 avec le câble d’alimentation domestique 14/2
dans la hotte à travers un passe-fils approuvé UL, convenant à
2 câbles. Ajouter un fil de MISE À LA TERRE et connecter une
de ses extrémités à la vis VERTE de mise à la terre. Utiliser un
capuchon de connexion approprié pour connecter l’autre bout du
fil de MISE À LA TERRE avec celui provenant du câble 14/3 et
celui du câble d’alimentation électrique domestique 14/2.
Utiliser un capuchon de connexion approprié pour connecter le fil
NOIR du câble d’alimentation domestique au fil BLANC du câble14/3.
Utiliser un capuchon de connexion approprié pour connecter le
fil NOIR du câble 14/3 au fil NOIR de la hotte.
Utiliser un capuchon de connexion approprié pour connecter le fil
BLANC du câble d’alimentation domestique au fil BLANC de la hotte.
Passer le fil ROUGE du câble 14/3 à travers l’ouverture pour les
fils de la plaque pliée pour la connexion à la commande de la
hotte. Voir en page suivante pour la connexion du fil ROUGE.
CÂBLE ÉLECTRIQUE DE 120 VCA
ALIMENTANT LINTERRUPTEUR
MISE À
LA TERRE
BLANC
BLANC
VERS LA HOTTE
CÂBLE 14/3
NOIR
NOIR
(Principal
marche/arrêt)
INTERRUPTEUR
DOUBLE
ROUGE
(Éclairage
prioritaire)
120 VCA
ALIMENTATION
DOMESTIQUE
VERS LA COMMANDE
DE LA HOTTE
FIL DE MISE À LA TERRE
DU MOTEUR
CÂBLE 14/3
ROUGE
NOIR
BLANC
MISE À
LA TERRE
1
2
3
4
Installer un interrupteur double à un emplacement
pratique pour l’utilisateur. Brancher l’interrupteur
à l’alimentation domestique de 120 VCA et utiliser
un câble 14/3 pour le connecter à la hotte (voir le
diagramme de droite).
Insérer le câble 14/3 dans la hotte à travers un passe-fils approuvé UL.
Connecter le fil de mise à la terre à la vis VERTE de mise à la terre.
Utiliser un capuchon de connexion approprié pour connecter le fil
BLANC du câble 14/3 au fil BLANC de la hotte.
Utiliser un capuchon de connexion approprié pour connecter le fil
NOIR du câble 14/3 au fil NOIR de la hotte.
Passer le fil ROUGE du câble 14/3 à travers l’ouverture pour les fils
de la plaque pliée pour la connexion à la commande de la hotte. Voir
en page suivante pour la connexion du fil ROUGE.
Éclairage
prioritaire
Principal
marche/arrêt
NOTE : Pvoir une longueur adéquate de câble 14/3 pour réaliser la
connexion du fil ROUGE à l’avant de la hotte.
NOTE : Pvoir une longueur adéquate de câble 14/3 pour
réaliser la connexion du fil ROUGE à l’avant de la hotte.
Éclairage
prioritaire
Principal
marche/arrêt
FIL BLEU
FIL ROUGE
DU CÂBLE 14/3
A
B
A Couper le fil BLEU du faisceau de fils de la commande à boutons-poussoirs.
B Connecter le fil ROUGE du câble 14/3 aux deux extrémités du fil BLEU à l’aide d’un
capuchon de connexion approprié.
CONNEXION DU FIL ROUGE
Série Broan : BCSM, BKSM, CKSL and CRDE
Série NuTone : NRSL
Série Venmar Bistro : VBNDE
NOTES : 1. Même si les commandes à boutons-poussoirs peuvent avoir 6 fils OU 5 fils connectés à la carte de la commande; cette
procédure convient aux deux modèles de commande à boutons-poussoirs puisque les deux n’ont qu’un seul fil BLEU.
2. Pour faciliter l’accès aux fils, débrancher le faisceau de fils de la carte de la commande avant d’effectuer les étapes
A et B.
6
Une fois toutes les connexions effectuées, terminer l’installation en inversant les étapes à de la page 4.
NOTE : Faire attention lors de la remise en place du couvercle du compartiment électrique dans la hotte.
VIS
LANGUETTES
DU DESSUS
INTERNE DE
LA HOTTE
ENGAGÉES
DANS LES
FENTES DU
COUVERCLE DU
COMPARTIMENT
ÉLECTRIQUE.
ATTENTION
S’assurer que les deux languettes du dessus interne de la hotte sont engagées dans les fentes correspondantes
du couvercle du compartiment électrique. Aussi, prendre garde de ne pas pincer les fi ls lors de la remise en
place du couvercle.
CETTE PROCÉDURE S’APPLIQUE AUX HOTTES À VENTILATEUR SIMPLE SUIVANTES :
INSTRUCCIONES DE CABLEADO DE ALTA TENSIÓN ENTRE CAMPANAS DE UN SOLO
VENTILADOR CON BOTÓN PULSADOR
ADVERTENCIA
!
Para instalación residencial (doméstica) solamente. Antes de continuar, apague la alimentación en el tablero de
servicio y bloquee los medios de desconexión para evitar que se conecte la corriente accidentalmente. Los trabajos
de instalación y el cableado eléctrico han de ser realizados por personas cualificadas, de conformidad con todos
los códigos y normas aplicables, incluyendo los códigos y normas de construcción contra incendios. Asimismo, se
aconseja llevar lentes y guantes de seguridad.
ACCESO A LAS CONEXIONES DEL TABLERO DE CONTROL DE LA CAMPANA
Quite los filtros de la campana y póngalos a un lado.
Retire el tornillo que sujeta la tapa del compartimento eléctrico
(parte sombreada de la ilustración de abajo). Deslice la tapa fuera
de la campana y póngala a un lado con el tornillo.
Desenchufe el conector del ventilador del mazo de cables principal.
Utilice una llave de tubo de 11/32’ para retirar las 6 tuercas que
sujetan la cámara del ventilador al conjunto de la campana (2 tuercas
en la parte trasera interior y 2 tuercas por lado); use luego un
destornillador Phillips no 2 para quitar los dos tornillos de las
esquinas delanteras. Véase en la imagen de abajo la ubicación de
las tuercas y los tornillos. Saque la cámara del ventilador desde
el conjunto de la campana y póngala a un lado con sus tornillos y
tuercas de sujeción.
HE0253
HD0672
Tuercas
Tuercas
Tornillo
Retire y ponga a un lado los 4 tornillos delanteros que sujetan la
placa doblada a la campana.
HD0673
Ubicaciones de los tornillos
Doble hacia atrás la placa doblada para acceder a las conexiones
del tablero de control.
HD0674
7
NOTA: Las ilustraciones de este procedimiento son genéricas; algunos detalles de la campana pueden ser ligeramente diferentes de la campana
que tenga delante, pero el procedimiento en sí se aplica a todas las campanas de un solo ventilador enumeradas en este documento
(véase la página 9).
Tornillo de
la tapa del
compartimento
eléctrico
Según sus necesidades, hay 2 maneras de conectar un interruptor oscilante doble a estas campanas: cuando el cable eléctrico de 120
VCA alimenta la campana o cuando el cable eléctrico de 120 VCA alimenta el interruptor doble
8
PRECAUCIÓN
Utilice interruptores estándar de una capacidad de 120 VCA, 15 A. Utilice sólo hilos que resistan una temperatura de
al menos 90°C (194°F). Asegúrese de que los hilos estén colocados lejos de las bombillas halógenas (de haberlas).
CABLE ELÉCTRICO DE 120 VCA
QUE ALIMENTA LA CAMPANA
BLANCO
TIERRA
HE0265E
ROJO
(Luz
prioritaria)
NEGRO
(Principal
Enc./Apa.)
INTERRUPTOR
DOBLE
LA CAMPANA
CABLE 14/3 HACIA
HACIA EL CONTROL
DE LA CAMPANA
HILO DE TIERRA
DEL MOTOR
CABLE 14/3
ALIMENTACIÓN
DOMÉSTICA
120 VCA
ROJO
NEGRO
BLANC
O
TIERRA
1
2
3
4
5
Instale un interruptor oscilante doble en un lugar práctico
para el usuario. Utilice un cable 14/3 para conectarlo a la
campana (véase el diagrama de la derecha).
NOTA: El código exige que se han de colorear los dos
extremos de la funda del hilo BLANCO; utilice un
rotulador permanente.
Introduzca el cable 14/3 con el cable de alimentación doméstica 14/2
en la campana a través de una abrazadera de hilos aprobada por
UL adecuada para 2 cables. Añada un hilo de TIERRA y conecte
uno de los extremos al tornillo VERDE de tierra. Use un capuchón de
conexión de hilos apropiado para conectar el otro extremo del hilo de
TIERRA con el hilo de tierra proveniente del cable 14/3 y con el hilo
del cable de alimentación eléctrica doméstica 14/2.
Conecte el hilo NEGRO del cable de alimentación doméstica con el
hilo BLANCO del cable 14/3 mediante un capuchón de conexión de
hilos adecuado.
Conecte el hilo NEGRO del cable 14/3 con el hilo NEGRO de la
campana mediante un capuchón de conexión de hilos adecuado.
Conecte el hilo BLANCO del cable de alimentación doméstica con el
hilo BLANCO de la campana mediante un capuchón de conexión de
hilos adecuado.
Pase el hilo ROJO del cable 14/3 a través de la abertura para los hilos
de la placa doblada para la conexión con el control de la campana.
Véase la página siguiente para la conexión del hilo ROJO.
CABLE ELÉCTRICO DE 120 VCA
QUE ALIMENTA EL INTERRUPTOR
TIERRA
BLANCO
BLANCO
HACIA LA
CAMPANA
CABLE 14/3
NEGRO
NTERRUPTOR
DOBLE
120 VCA
ALIMENTACIÓN
DOMÉSTICA
ROJO
(Luz
prioritaria)
NEGRO
(Principal
Enc./Apa.)
HACIA EL CONTROL
DE LA CAMPANA
HILO DE TIERRA
DEL MOTOR
CABLE 14/3
ROJO
NEGRO
BLANCO
TIERRA
1
2
3
4
Instale un interruptor oscilante doble en un lugar práctico
para el usuario. Conecte el interruptor con la alimentación
doméstica de 120 VCA y utilice un cable 14/3 para
conectarlo a la campana (véase el diagrama de la derecha).
Luz
prioritaria
Principal
Enc./Apa.
NOTA: Prevea una longitud adecuada de cable 14/3 para
conectar el hilo ROJO en la parte delantera de la campana.
Luz
prioritaria
Principal
Enc./Apa.
Introduzca el cable 14/3 en la campana a través de una abrazadera de
hilos aprobada por UL. Conecte el hilo de TIERRA al tornillo VERDE de
tierra.
Conecte el hilo BLANCO del cable 14/3 con el hilo BLANCO de la
campana mediante un capuchón de conexión de hilos adecuado.
Conecte el hilo NEGRO del cable 14/3 con el hilo NEGRO de la
campana mediante un capuchón de conexión de hilos adecuado.
Pase el hilo ROJO del cable 14/3 a través de la abertura para los hilos
de la placa doblada para la conexión con el control de la campana.
Véase la página siguiente para la conexión del hilo ROJO.
NOTA: Prevea una longitud adecuada de cable 14/3 para conectar el hilo
ROJO en la parte delantera de la campana.
HILO AZUL
HILO ROJO
DEL CABLE 14/3
HE0264E
A
B
NOTAS: 1. Los controles del botón pulsador pueden tener 6 o 5 hilos conectados a la tarjeta de control; el siguiente procedimiento se aplica a
ambos modelos de control del botón pulsador, ya que estos 2 modelos sólo tienen un hilo AZUL.
2. Para facilitar el acceso a los hilos, desconecte el mazo de hilos de la tarjeta de control antes de las etapas A y B.
A Corte el hilo AZUL del mazo de hilos del control del botón pulsador.
B Conecte el hilo ROJO del cable 14/3 con los dos extremos del hilo AZUL mediante un
capuchón de conexión de hilos adecuado.
CONEXIÓN DEL HILO ROJO
ESTE PROCEDIMIENTO SE APLICA A LAS SIGUIENTES CAMPANAS CON UN SOLO VENTILADOR:
Una vez hechas todas las conexiones, termine la instalación invirtiendo las etapas a de la página 7.
NOTA: Tenga cuidado al colocar en su lugar la tapa del compartimento eléctrico de la campana.
PRECAUCIÓN
Compruebe que ambas aletas de la parte superior interna de la campana se hayan introducido en sus ranuras
correspondientes en la tapa del compartimento eléctrico. Asimismo, procure que los hilos no queden pellizcados
al volver a colocar la tapa.
TORNILLO
ALETAS DE LA PARTE
SUPERIOR INTERNA
DE LA CAMPANA
NTRODUCIDAS EN
LAS RANURAS DE
LA TAPA DEL
COMPARTIMENTO
ELÉCTRICO.
9
Series Broan: BCSM, BKSM, CKSL and CRDE
Serie NuTone: NRSL
Serie Venmar Bistro: VBNDE

Transcripción de documentos

ADA HIGH VOLTAGE WIRING INSTRUCTIONS FOR SINGLE BLOWER RANGE HOODS WITH PUSH-BUTTON CONTROL ! WARNING For residential (domestic) installation only. Before proceeding, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards. Also, it is recommended to wear safety glasses and gloves. ACCESS TO RANGE HOOD CONTROL PANEL CONNECTIONS NOTE: The illustrations in this procedure are generic; some hood details may slightly differ from the hood you have on hand but the procedure itself applies to all single blower range hoods listed in this document (see page 3).  Remove filters from the hood and set them aside.  Using a 11/32'' socket, remove the 6 nuts retaining the blower chamber to the hood assembly (2 nuts on inner back and 2 other nuts per sides), then use a Phillips no. 2 screwdriver to remove both front corner screws. See picture below for nuts and screws locations. Pull out the blower chamber from the hood assembly and set it aside with its retaining screws and nuts. NOTE: Some models have only one filter.  Remove the wiring cover (shaded part on illustration below) retaining screw. Slide out the wiring cover from the hood and set it aside with its screw. Nuts Wiring cover screw Screw Nuts  Unplug the blower connector from the main harness. HD0672  Remove and set aside the 4 front screws retaining the bent plate to the hood. Screw locations HD0673  Fold back the bent plate to access to control panel connections. HE0253 HD0674 1 99045860A CAUTION Use standard switches that are rated 120 VCA, 15 A. Only use wires suitable for at least 90oC (194oF). Ensure the wires are reliably routed away from the halogen lights (if present). According to your needs, there are 2 ways to wire a 2-rocker switch control to these range hoods: 120 VAC power cable entering the range hood or 120 VAC power cable entering the switch box. 120 VAC POWER CABLE ENTERING THE HOOD 2-ROCKER SWITCH RED (Light override) Install a 2-rocker switch at a convenient place for the user. Use a 14/3 cable to wire it to the range hood (see diagram at right). Light override GROUND WHITE Master ON/OFF NOTE: Code requires both ends of WHITE wire insulation to be colored; use a permanent marker. BLACK (Master ON/OFF) NOTE: Allow enough length of 14/3 cable to perform the RED wire HE0265A connection in the hood nose. 3  Insert the 14/3 cable along with the 14/2 house wiring cable in the hood through an UL approved wire clamp, suitable for 2 cables. Add a GROUND wire and connect one end to the GREEN ground screw. Use an appropriate wire nut to connect the other end of the added GROUND wire with the ground wire coming from the 14/3 cable and the ground wire coming from 14/2 house wiring cable. 14/3 TO HOOD 5 TO CONTROL PANEL 2 4 MOTOR GROUND WIRE  Connect BLACK wire from house wiring to WHITE wire from 14/3 cable using an appropriate wire nut. BLACK  Connect BLACK wire from 14/3 cable to BLACK wire from range WHITE hood wiring using an appropriate wire nut.  Connect WHITE wire from house wiring to WHITE wire range hood wiring using an appropriate wire nut. 1  Run RED wire from 14/3 cable through bend plate wiring opening 120 VAC HOUSE WIRING for hood control connection. See next page for RED wire connection. RED GROUND 14/3 CABLE 120 VAC POWER CABLE ENTERING THE SWITCH 2-ROCKER SWITCH Light override RED (Light override) GROUND Install a 2-rocker switch at a convenient place for the user. Feed the switch box with 120 VAC house wiring and use a 14/3 cable to wire it to the range hood (see diagram at right). BLACK 14/3 CABLE TO HOOD WHITE BLACK (Master ON/OFF) Master ON/OFF WHITE 120 VAC LINE IN NOTE: Allow enough length of 14/3 cable to perform the RED wire connection in the hood nose. 4 TO CONTROL PANEL  Insert the 14/3 cable in the hood through an UL approved wire clamp. Connect ground wire to the GREEN ground screw. 3 2 MOTOR GROUND WIRE  Connect WHITE wire from 14/3 cable to WHITE wire from range hood wiring using an appropriate wire nut. BLACK  Connect BLACK wire from 14/3 cable to BLACK wire from range hood wiring using an appropriate wire nut.  Run RED wire from 14/3 cable through bend plate wiring opening for WHITE 1 hood control connection. See next page for RED wire connection. 14/3 CABLE 2 RED GROUND RED WIRE CONNECTION NOTES: 1. The push-button controls may have 6 wires OR 5 wires connected to the control board; the procedure below applies to both push-button control models since these 2 models have only one BLUE wire. 2. To ease access to wires, disconnect the harness from the control board before performing steps A and B. A Cut the BLUE wire of the push button control harness. A BLUE WIRE B Connect the RED wire from 14/3 cable to both ends of the BLUE wire, using an appropriate wire nut. B RED WIRE FROM 14/3 CABLE Once all the connections are done, finalize the installation by reversing steps  to  on first page. NOTE: Be careful while reinstalling wiring cover to the hood. SCREW TABS ON INNER TOP OF HOOD ENGAGED IN WIRING COVER SLOTS. CAUTION Ensure both tabs on inner top of hood are engaged in their corresponding slots in wiring cover. Also, take care not to pinch wires while reinstalling wiring cover. THIS PROCEDURE APPLIES TO THE FOLLOWING RANGE HOOD SERIES Broan Series: BCSM, BKSM, CKSL and CRDE NuTone Series: NRSL Venmar Bistro Series: VBNDE 3 INSTRUCTIONS DE CÂBLAGE HAUTE TENSION ENTRE LES HOTTES À VENTILATEUR SIMPLE À BOUTONS-POUSSOIRS ET UNE COMMANDE MURALE ! AVERTISSEMENT Uniquement pour une installation résidentielle (domestique). Avant de commencer, coupez le courant au panneau d’alimentation et verrouillez-en l’accès afin d’éviter sa remise en marche accidentelle. Les travaux d’installation et de raccordement électrique doivent être effectués par une personne qualifiée, conformément aux codes et aux standards de construction, incluant ceux concernant la protection contre les incendies. Aussi, il est recommandé de porter des lunettes et des gants de sécurité. ACCÈS AUX CONNEXIONS DU PANNEAU DE COMMANDE NOTE : Les illustrations de cette procédure sont génériques; certains détails de hotte peuvent différer légèrement de ceux qui sont sur la hotte que vous avez en main, cependant cette procédure s'applique sur toutes les hottes à ventilateur simple citées dans ce document (voir page 6).  Retirer les deux filtres de la hotte et les mettre de côté.  À l’aide d’une douille de 11/32 po, retirer les 6 écrous retenant le caisson du ventilateur à la hotte (2 écrous au dos intérieur de la hotte et 2 autres écrous par côtés), puis utiliser un tournevis Phillips n° 2 pour retirer les 2 vis des coins avant. Voir la photo de droite pour l’emplacement des écrous et des vis. Soulever hors de la hotte le caisson du ventilateur et le mettre de côté avec ses vis et écrous. NOTE : Certains modèles n’ont qu’un seul filtre.  Retirer la vis de retenue du couvercle du compartiment électrique (en gris dans l’illustration ci-dessous). Glisser le couvercle hors de la hotte et le mettre de côté avec sa vis. Écrous Vis du couvercle du compartiment électrique Écrous Vis  Débrancher le connecteur du ventilateur du faisceau électrique principal. HD0672  Retirer et mettre de côté les 4 vis avant retenant la plaque pliée à la hotte. Emplacement des vis HD0673  Plier vers l’arrière la plaque pliée afin d’accéder au dessous du panneau de contrôle. HE0253 4 HD0674 ATTENTION Utiliser des interrupteurs standards d’une capacité de 120 VCA, 15 A. Utilisez des fils pouvant supporter une température d’au moins 90oC (194oF). S’assurer que les fils sont placés loin des ampoules halogènes (si présentes). Selon vos besoins, il existe 2 façons de raccorder un interrupteur double à ces hottes : lorsque le câble électrique de 120 VCA alimente la hotte ou lorsque le câble électrique de 120 VCA alimente l’interrupteur double. CÂBLE ÉLECTRIQUE DE 120 VCA ALIMENTANT LA HOTTE INTERRUPTEUR DOUBLE ROUGE (Éclairage prioritaire) Installer un interrupteur double à un emplacement pratique pour l’utilisateur. Utiliser un câble 14/3 pour le raccorder à la hotte (voir le diagramme de droite). NOTE : Le code exige de colorer les deux extrémités de la gaine du fil BLANC; utiliser un marqueur permanent. Éclairage prioritaire MISE À LA TERR BLANC Principal marche/arrêt NOIR (Principal marche/arrêt) NOTE : Prévoir une longueur adéquate de câble 14/3 pour HE0265F réaliser la connexion du fil ROUGE à l’avant de la hotte. 3  Insérer le câble 14/3 avec le câble d’alimentation domestique 14/2 dans la hotte à travers un passe-fils approuvé UL, convenant à 2 câbles. Ajouter un fil de MISE À LA TERRE et connecter une de ses extrémités à la vis VERTE de mise à la terre. Utiliser un capuchon de connexion approprié pour connecter l’autre bout du fil de MISE À LA TERRE avec celui provenant du câble 14/3 et celui du câble d’alimentation électrique domestique 14/2. CÂBLE 14/3 VERS LA HOTTE 5 VERS LA COMMANDE DE LA HOTTE 2 4 FIL DE MISE À LA TERRE DU MOTEUR  Utiliser un capuchon de connexion approprié pour connecter le fil NOIR du câble d’alimentation domestique au fil BLANC du câble14/3. NOIR  Utiliser un capuchon de connexion approprié pour connecter le BLANC fil NOIR du câble 14/3 au fil NOIR de la hotte.  Utiliser un capuchon de connexion approprié pour connecter le fil BLANC du câble d’alimentation domestique au fil BLANC de la hotte.  Passer le fil ROUGE du câble 14/3 à travers l’ouverture pour les fils de la plaque pliée pour la connexion à la commande de la hotte. Voir en page suivante pour la connexion du fil ROUGE. CÂBLE ÉLECTRIQUE DE 120 VCA ALIMENTANT L’INTERRUPTEUR 1 ALIMENTATION DOMESTIQUE 120 VCA ROUGE MISE À LA TERRE CÂBLE 14/3 INTERRUPTEUR DOUBLE Installer un interrupteur double à un emplacement pratique pour l’utilisateur. Brancher l’interrupteur à l’alimentation domestique de 120 VCA et utiliser un câble 14/3 pour le connecter à la hotte (voir le diagramme de droite). ROUGE (Éclairage prioritaire) Éclairage prioritaire MISE À LA TERRE NOIR CÂBLE 14/3 VERS LA HOTTE BLANC Principal marche/arrêt BLANC NOIR 120 VCA (Principal ALIMENTATION marche/arrêt) DOMESTIQUE NOTE : Prévoir une longueur adéquate de câble 14/3 pour réaliser la connexion du fil ROUGE à l’avant de la hotte.  Insérer le câble 14/3 dans la hotte à travers un passe-fils approuvé UL. Connecter le fil de mise à la terre à la vis VERTE de mise à la terre. 4 3 VERS LA COMMANDE DE LA HOTTE 2 FIL DE MISE À LA TERRE DU MOTEUR  Utiliser un capuchon de connexion approprié pour connecter le fil BLANC du câble 14/3 au fil BLANC de la hotte. NOIR  Utiliser un capuchon de connexion approprié pour connecter le fil NOIR du câble 14/3 au fil NOIR de la hotte.  Passer le fil ROUGE du câble 14/3 à travers l’ouverture pour les fils de la plaque pliée pour la connexion à la commande de la hotte. Voir en page suivante pour la connexion du fil ROUGE. 5 BLANC 1 CÂBLE 14/3 ROUGE MISE À LA TERRE CONNEXION DU FIL ROUGE NOTES : 1. Même si les commandes à boutons-poussoirs peuvent avoir 6 fils OU 5 fils connectés à la carte de la commande; cette procédure convient aux deux modèles de commande à boutons-poussoirs puisque les deux n’ont qu’un seul fil BLEU. 2. Pour faciliter l’accès aux fils, débrancher le faisceau de fils de la carte de la commande avant d’effectuer les étapes A et B. A Couper le fil BLEU du faisceau de fils de la commande à boutons-poussoirs. A FIL BLEU B Connecter le fil ROUGE du câble 14/3 aux deux extrémités du fil BLEU à l’aide d’un capuchon de connexion approprié. B FIL ROUGE DU CÂBLE 14/3 Une fois toutes les connexions effectuées, terminer l’installation en inversant les étapes  à  de la page 4. NOTE : Faire attention lors de la remise en place du couvercle du compartiment électrique dans la hotte. VIS LANGUETTES DU DESSUS INTERNE DE LA HOTTE ENGAGÉES DANS LES FENTES DU COUVERCLE DU COMPARTIMENT ÉLECTRIQUE. ATTENTION S’assurer que les deux languettes du dessus interne de la hotte sont engagées dans les fentes correspondantes du couvercle du compartiment électrique. Aussi, prendre garde de ne pas pincer les fils lors de la remise en place du couvercle. CETTE PROCÉDURE S’APPLIQUE AUX HOTTES À VENTILATEUR SIMPLE SUIVANTES : Série Broan : BCSM, BKSM, CKSL and CRDE Série NuTone : NRSL Série Venmar Bistro : VBNDE 6 INSTRUCCIONES DE CABLEADO DE ALTA TENSIÓN ENTRE CAMPANAS DE UN SOLO VENTILADOR CON BOTÓN PULSADOR ! ADVERTENCIA Para instalación residencial (doméstica) solamente. Antes de continuar, apague la alimentación en el tablero de servicio y bloquee los medios de desconexión para evitar que se conecte la corriente accidentalmente. Los trabajos de instalación y el cableado eléctrico han de ser realizados por personas cualificadas, de conformidad con todos los códigos y normas aplicables, incluyendo los códigos y normas de construcción contra incendios. Asimismo, se aconseja llevar lentes y guantes de seguridad. ACCESO A LAS CONEXIONES DEL TABLERO DE CONTROL DE LA CAMPANA NOTA: Las ilustraciones de este procedimiento son genéricas; algunos detalles de la campana pueden ser ligeramente diferentes de la campana que tenga delante, pero el procedimiento en sí se aplica a todas las campanas de un solo ventilador enumeradas en este documento (véase la página 9).  Quite los filtros de la campana y póngalos a un lado.  Utilice una llave de tubo de 11/32’’ para retirar las 6 tuercas que sujetan la cámara del ventilador al conjunto de la campana (2 tuercas en la parte trasera interior y 2 tuercas por lado); use luego un destornillador Phillips no 2 para quitar los dos tornillos de las esquinas delanteras. Véase en la imagen de abajo la ubicación de las tuercas y los tornillos. Saque la cámara del ventilador desde el conjunto de la campana y póngala a un lado con sus tornillos y tuercas de sujeción.  Retire el tornillo que sujeta la tapa del compartimento eléctrico (parte sombreada de la ilustración de abajo). Deslice la tapa fuera de la campana y póngala a un lado con el tornillo. Tuercas Tornillo de la tapa del compartimento eléctrico Tornillo Tuercas  Desenchufe el conector del ventilador del mazo de cables principal. HD0672  Retire y ponga a un lado los 4 tornillos delanteros que sujetan la placa doblada a la campana. Ubicaciones de los tornillos HD0673  Doble hacia atrás la placa doblada para acceder a las conexiones del tablero de control. HE0253 HD0674 7 PRECAUCIÓN Utilice interruptores estándar de una capacidad de 120 VCA, 15 A. Utilice sólo hilos que resistan una temperatura de al menos 90°C (194°F). Asegúrese de que los hilos estén colocados lejos de las bombillas halógenas (de haberlas). Según sus necesidades, hay 2 maneras de conectar un interruptor oscilante doble a estas campanas: cuando el cable eléctrico de 120 VCA alimenta la campana o cuando el cable eléctrico de 120 VCA alimenta el interruptor doble CABLE ELÉCTRICO DE 120 VCA QUE ALIMENTA LA CAMPANA INTERRUPTOR DOBLE Instale un interruptor oscilante doble en un lugar práctico para el usuario. Utilice un cable 14/3 para conectarlo a la campana (véase el diagrama de la derecha). ROJO (Luz prioritaria) Luz prioritaria TIERRA BLANCO NOTA: El código exige que se han de colorear los dos extremos de la funda del hilo BLANCO; utilice un rotulador permanente. Principal Enc./Apa. NOTA: Prevea una longitud adecuada de cable 14/3 para HE0265E conectar el hilo ROJO en la parte delantera de la campana. NEGRO (Principal Enc./Apa.) CABLE 14/3 HACIA LA CAMPANA 3  Introduzca el cable 14/3 con el cable de alimentación doméstica 14/2 en la campana a través de una abrazadera de hilos aprobada por UL adecuada para 2 cables. Añada un hilo de TIERRA y conecte uno de los extremos al tornillo VERDE de tierra. Use un capuchón de conexión de hilos apropiado para conectar el otro extremo del hilo de TIERRA con el hilo de tierra proveniente del cable 14/3 y con el hilo del cable de alimentación eléctrica doméstica 14/2.  Conecte el hilo NEGRO del cable de alimentación doméstica con el hilo BLANCO del cable 14/3 mediante un capuchón de conexión de hilos adecuado.  Conecte el hilo NEGRO del cable 14/3 con el hilo NEGRO de la campana mediante un capuchón de conexión de hilos adecuado. 5 HACIA EL CONTROL DE LA CAMPANA 2 4 HILO DE TIERRA DEL MOTOR NEGRO BLANCO 1  Conecte el hilo BLANCO del cable de alimentación doméstica con el hilo BLANCO de la campana mediante un capuchón de conexión de hilos adecuado.  Pase el hilo ROJO del cable 14/3 a través de la abertura para los hilos de la placa doblada para la conexión con el control de la campana. Véase la página siguiente para la conexión del hilo ROJO. CABLE ELÉCTRICO DE 120 VCA QUE ALIMENTA EL INTERRUPTOR Instale un interruptor oscilante doble en un lugar práctico para el usuario. Conecte el interruptor con la alimentación doméstica de 120 VCA y utilice un cable 14/3 para conectarlo a la campana (véase el diagrama de la derecha). ALIMENTACIÓN DOMÉSTICA 120 VCA NTERRUPTOR DOBLE ROJO (Luz prioritaria) ROJO TIERRA CABLE 14/3 Luz prioritaria TIERRA CABLE 14/3 HACIA LA CAMPANA NEGRO BLANCO NEGRO (Principal Enc./Apa.) Principal Enc./Apa. BLANCO 120 VCA ALIMENTACIÓN DOMÉSTICA NOTA: Prevea una longitud adecuada de cable 14/3 para conectar el hilo ROJO en la parte delantera de la campana.  Introduzca el cable 14/3 en la campana a través de una abrazadera de hilos aprobada por UL. Conecte el hilo de TIERRA al tornillo VERDE de tierra. 4 3 HACIA EL CONTROL DE LA CAMPANA 2 HILO DE TIERRA DEL MOTOR  Conecte el hilo BLANCO del cable 14/3 con el hilo BLANCO de la campana mediante un capuchón de conexión de hilos adecuado. NEGRO  Conecte el hilo NEGRO del cable 14/3 con el hilo NEGRO de la campana mediante un capuchón de conexión de hilos adecuado.  Pase el hilo ROJO del cable 14/3 a través de la abertura para los hilos de la placa doblada para la conexión con el control de la campana. Véase la página siguiente para la conexión del hilo ROJO. 8 BLANCO 1 CABLE 14/3 ROJO TIERRA CONEXIÓN DEL HILO ROJO NOTAS: 1. Los controles del botón pulsador pueden tener 6 o 5 hilos conectados a la tarjeta de control; el siguiente procedimiento se aplica a ambos modelos de control del botón pulsador, ya que estos 2 modelos sólo tienen un hilo AZUL. 2. Para facilitar el acceso a los hilos, desconecte el mazo de hilos de la tarjeta de control antes de las etapas A y B. A A Corte el hilo AZUL del mazo de hilos del control del botón pulsador. HILO AZUL B B Conecte el hilo ROJO del cable 14/3 con los dos extremos del hilo AZUL mediante un capuchón de conexión de hilos adecuado. HILO ROJO DEL CABLE 14/3 HE0264E Una vez hechas todas las conexiones, termine la instalación invirtiendo las etapas  a  de la página 7. NOTA: Tenga cuidado al colocar en su lugar la tapa del compartimento eléctrico de la campana. PRECAUCIÓN Compruebe que ambas aletas de la parte superior interna de la campana se hayan introducido en sus ranuras correspondientes en la tapa del compartimento eléctrico. Asimismo, procure que los hilos no queden pellizcados al volver a colocar la tapa. TORNILLO ALETAS DE LA PARTE SUPERIOR INTERNA DE LA CAMPANA NTRODUCIDAS EN LAS RANURAS DE LA TAPA DEL COMPARTIMENTO ELÉCTRICO. ESTE PROCEDIMIENTO SE APLICA A LAS SIGUIENTES CAMPANAS CON UN SOLO VENTILADOR: Series Broan: BCSM, BKSM, CKSL and CRDE Serie NuTone: NRSL Serie Venmar Bistro: VBNDE 9
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

Venmar VBNDE1 Instrucciones de operación

Tipo
Instrucciones de operación