NuTone EZ80N Guía de instalación

Tipo
Guía de instalación
EZ80N
EZ Fit
Ventilation Fan
INSTALLATION GUIDE
READ AND SAVE THESE INSTRUCTIONS
Installer: leave this guide with homeowner.
Register your product online at www.nutone.com/register.
Easy installation
Table of Contents
Warnings and Cautions 2
Operation 2
Cleaning and Maintenance 2
Troubleshooting 2
Typical Installation 2
Installation - Replace an Existing Fan 3-7
Installation in New Construction 7
Service Parts 8
Warranty 8
© 2013 Broan-NuTone LLC
EZ80N
n
Installation Guide
Page 2
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the
address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten
a prominent warning device, such as a tag, to the service
panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), and the local code
authorities.
5. When cutting or drilling into a ceiling, do not damage electrical
wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower (in the ceiling only)
when connected to a GFCI (Ground Fault Circuit Interrupter)
- protected branch circuit.
8. This unit must be grounded.
Typical Installation
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. DO NOT install this unit onto an acoustic ceiling panel.
3. When installed in a sloped ceiling, the duct connector must
point up.
4. To avoid motor bearing damage and noisy and/or
unbalanced impellers, keep drywall spray, construction
dust, etc. off power unit.
5. Please read specification label on product for further
information and requirements.
45° 45°
NOT FOR USE IN A COOKING AREA
Do not install above or inside this area
Floor
Cooking
Equipment
*Purchase
separately.
INSULATION*
(Place around and
over Fan Housing.)
ROOF CAP*
(with built-in
damper)
FAN
HOUSING
POWER
CABLE*
ROUND
DUCT*
ROUND
ELBOWS*
Seal gaps
around
Housing.
Seal duct
joints with
tape.
OR
Keep duct
runs short.
WALL CAP*
(with built-in
damper)
CEILING INSTALLATION SHOWN
Operation
To Operate Fan
Use an ON/OFF switch or speed control to operate this
ventilator.
WARNING Before servicing or cleaning unit,
switch power off at service panel and lock the service
disconnecting means to prevent power from being switched on
accidentally. When the service disconnecting means cannot be
locked, securely fasten a prominent warning device, such as a
tag, to the service panel.
Cleaning and Maintenance
To Clean
For quiet and efficient operation, long life and attractive
appearance, remove Grille and vacuum interior of unit with a
dusting brush attachment.
The Motor is permanently lubricated and never needs oiling. If
the motor bearings are making excessive or unusual noises,
replace the Motor.
Troubleshooting
Symptom: The fan does not run.
• Checkforanopenfuseorcircuitbreakerinthebuilding’s
service panel.
• Checkthattheplug-inconnectionfortheMotorisseated
firmly in place.
• CheckthattheBlowerWheelspinsfreely.
Symptom: The fan runs erratically.
• CheckthattheBlowerWheelisfirmlyattachedtotheMotor
shaft and both spin freely.
Symptom: The fan seems noisy.
• Checkthatthebackdraftdamperinthefan’sDuctConnector
pivots freely. Screws used to attach the ducting to the Duct
Connector may be preventing the damper from opening.
• Checkthatthebackdraftdamperinthewallorroofcappivots
freely. These dampers are sometimes mistakenly painted shut
or obstructed by bird and insect debris.
EZ80N
n
Installation Guide
Page 3
Punch out
Template from
packaging. See
Step 3.
Installation - Replace an Existing Fan
Tools needed
• Phillipsscrewdriver(recommended)
• Hammer
• Safetyglasses
• Pencil
• TapeMeasure
• Drywallsaw
Materials needed
• 4"roundmetalductingrecommendedforbestperformance. Useof
other ducting is acceptable but may impact performance.
• Roofcaporwallcap(built-indamperrecommended)
• Tapetosealductconnections
• Drywallscrews,sheetmetalscrews(optional)
• Electricalwiringandsuppliesperlocalcoderequirements
1
Remove from Packaging
2
Prepare the Housing
Loosen 2 blower
screws.
Unplug blower
and remove
blower from
housing.
1
2
3
Remove wiring cover.
EZ80N
n
Installation Guide
Page 4
Installation - Replace an Existing Fan
3
Mark Ceiling Using Template
C
L
8” MAX.
8¼” MAX.
10¾”
12¼”
JOIST
CENTER LINE
OF INSTALLATION
LOCATION OF
NEW FAN’S
DUCT CONNECTOR
For retrofit installations: Place this edge against ceiling framing.
(See installation instructions.)
C
L
JOIST
CENTER LINE
OF INSTALLATION
LOCATION OF
NEW FAN’S
DUCT CONNECTOR
For retrofit installations: Place this edge against ceiling framing.
(See installation instructions.)
Mark center line
of existing fan
on ceiling.
2
Position
template over
existing fan with
arrow on center line.
3
4
Trace around outside
of template with a
pencil.
1
Use a drywall saw to
cut out ceiling material
where marked.
WARNING
Be careful to avoid cutting through
electrical wiring or ductwork.
2
Disconnect electrical
wiring and ductwork -
then remove existing fan.
4
Cut Ceiling Opening & Remove Old Fan
JOIST
JOIST
Make sure existing
fan is no larger
than 8” x 8¼”.
1
EZ80N
n
Installation Guide
Page 5
Installation - Replace an Existing Fan
5
Install New Housing
Lift new fan
housing up into
enlarged rectangle
in ceiling material.
Hold housing firmly up
against ceiling material
and carefully tighten 4
clamps with a Phillips
screwdriver.
When turned clockwise (with a Phillips screwdriver), clamps
will spin outward from housing and move downward on top of
ceiling material to properly secure housing in place. Minimum
ceiling thickness to be 1/2”.
NOTE: Do not overtighten clamps with a power driver.
Ceiling material may become deformed and prevent
proper installation.
1
Adjust 4” ductwork into housing and use duct tape
to attach it to 4” duct connector. Rigid duct may
have to be cut to fit prior to housing installation.
For 3” ductwork, use the 4” to 3” reducer (provided).
See below.
2
Put 4” duct
connector into
opening and fasten
to housing with
tab and screw
provided.
É
É
4"to3"
Reducer
(provided)
3"Ducting
Tape
Tape
4"Duct
Connector
6
Connect Ductwork
2
1
EZ80N
n
Installation Guide
Page 6
Installation - Replace an Existing Fan
120 VAC
LINE IN
GRD
WHT
BLK
GRD
WHT
BLK BLK
WHT
UNITSWITCH BOX
ON/OFF
SWITCH
M
ON/OFF
SWITCH
(purchase separately)
KNOCKOUT
PLATE
RECEPTACLE
120 VAC LINE IN
SWITCH BOX
BLACK
WHITE
GROUND (green or bare)
Connect house wiring to
wiring plate with UL approved
connector.
Connect wiring as
shown in diagrams.
Attach wiring plate and wiring
cover to inside of housing with
screws provided.
Plug blower
into receptacle
and re-install
blower. Tighten
blower screws.
7
Connect Electrical Wiring
8
Replace Blower
9
Install Grille
Squeeze
grille springs
and insert
into slots in
blower.
1
Push grille up against ceiling.
2
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
If unfamiliar with electrical wiring, secure the services of a
qualified person to connect wiring according to all applicable
codes and standards.
EZ80N
n
Installation Guide
Page 7
Installation in New Construction
3
Install Fan Housing & Connect Ductwork
1
Push 4” duct
connector
into opening
and fasten
to housing
with tab
and screw
provided.
Use duct tape to connect 4” ductwork to 4” duct connector.
For 3” ductwork, use the 4” to 3” reducer (provided). See
below.
É
É
4"to3"
Reducer
(provided)
3"Ducting
Tape
Tape
4"Duct
Connector
4
3
Position fan against ceiling framing with bottom edge of
housing flush with finished ceiling.
Use 4 screws to attach housing to framing.
Optional for additional support: After ceiling is finished,
rotate the tightening clamps as described in Step 5.
In new construction
(before ceiling is finished):
Attachhousingto2"x6"orgreaterceilingjoists.
Use additional blocking as needed.
JOISTS I-JOISTS TRUSSES
ADDITIONAL BLOCKING
1
Remove from Packaging (See Page 3)
2
Prepare the Housing (See Page 3)
2
4
See “Connect Electrical Wiring” on Page 6.
5
See “Replace Blower” on Page 6.
6
See “Install Grille on Page 6.
EZ80N
n
Installation Guide
Page 8
Service Parts
Order replacement parts by Part No., not by Key No.
Key No. Part No. Description
1 79110158 4” to 3” Reducer
2 97019326 Wiring Plate
3 77001297 Capacitor
4 77001447 Tightening Clamps
(includes 4 screws & clamps)
5 97019006 Wire Cover Assembly
6 77001277 Duct Connector Assembly
7 97019349 Blower Assembly
8 79140014 Grille Spring (2 included)
9 97019525 Grille Assembly
(includes 2 grille springs)
Warranty
99045222A
1
2
3
5
6
7
9
4
8
Limited Warranty
Warranty Period and Exclusions: Broan-NuTone LLC (the “Company”) warrants to the original
consumer purchaser of its product (“you”) that the product (the “Product”) will be free from material
defects in the Product or its workmanship for a period of one (1) year from the date of original
purchase.
The limited warranty period for any replacement parts provided by the Company and for any Products
repaired or replaced under this limited warranty shall be the remainder of the original warranty period.
This warranty does not cover speed controls, fluorescent lamp starters, tubes, halogen and
incandescent bulbs, fuses, filters, ducts, roof caps, wall caps and other accessories for ducting
that may be purchased separately and installed with the Product. This warranty also does not cover
(a) normal maintenance and service, (b) normal wear and tear, (c) any Products or parts which
have been subject to misuse, abuse, abnormal usage, negligence, accident, improper or insufficient
maintenance, storage or repair (other than repair by the Company), (d)damage caused by faulty
installation, or installation or use contrary to recommendations or instructions, (e) any Product
that has been moved from its original point of installation, (f) damage caused by environmental
or natural elements, (g)damage in transit, (h)natural wear of finish, (i) Products in commercial
or nonresidential use, or (j)damage caused by fire, flood or other act of God. This warranty covers
only Products sold to original consumers in the United States by the Company or U.S. distributors
authorized by the Company.
This warranty supersedes all prior warranties and is not transferable from the original consumer
purchaser.
No Other Warranties: This Limited Warranty contains the Company’s sole obligation and your
sole remedy for defective products. The foregoing warranties are exclusive and in lieu of any other
warranties, express or implied. THE COMPANY DISCLAIMS AND EXCLUDES ALL OTHER EXPRESS
WARRANTIES, AND DISCLAIMS AND EXCLUDES ALL WARRANTIES IMPLIED BY LAW, INCLUDING
WITHOUT LIMITATION THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
To the extent that applicable law prohibits the exclusion of implied warranties, the duration of any
applicable implied warranty is limited to the period specified for the express warranty above. Some
states do not allow limitations on how long an implied warranty lasts, so the above limitation may
not apply to you. Any oral or written description of the Product is for the sole purpose of identifying
it and shall not be construed as an express warranty.
Whenever possible, each provision of this Limited Warranty shall be interpreted in such manner as to
be effective and valid under applicable law, but if any provision is held to be prohibited or invalid, such
provision shall be ineffective only to the extent of such prohibition or invalidity, without invalidating
the remainder of such provision or the other remaining provisions of the Limited Warranty.
Remedy: During the applicable limited warranty period, the Company will, at its option, provide
replacement parts for, or repair or replace, without charge, any Product or part thereof, to the extent
the Company finds it to be covered by and in breach of this limited warranty under normal use and
service. The Company will ship the repaired or replaced Product or replacement parts to you at
no charge. You are responsible for all costs for removal, reinstallation and shipping, insurance or
other freight charges incurred in the shipment of the Product or part to the Company. If you must
send the Product or part to the Company, as instructed by the Company, you must properly pack
the Product or part—the Company is not responsible for damage in transit. The Company reserves
the right to utilize reconditioned, refurbished, repaired or remanufactured Products or parts in the
warranty repair or replacement process. Such Products and parts will be comparable in function and
performance to an original Product or part and warranted for the remainder of the original warranty
period.
Exclusion of Damages: THE COMPANY’S OBLIGATION TO PROVIDE REPLACEMENT PARTS, OR
REPAIR OR REPLACE, AT THE COMPANY’S OPTION, SHALL BE YOUR SOLE AND EXCLUSIVE
REMEDY UNDER THIS LIMITED WARRANTY AND THE COMPANY’S SOLE AND EXCLUSIVE
OBLIGATION. THE COMPANY SHALL NOT BE LIABLE FOR INCIDENTAL, INDIRECT, CONSEQUENTIAL
OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE PRODUCT, ITS USE OR
PERFORMANCE.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the
above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and
you may also have other rights, which vary from state to state.
This warranty covers only replacement or repair of defective Products or parts thereof at the
Company’s main facility and does not include the cost of field service travel and living expenses.
Any assistance the Company provides to or procures for you outside the terms, limitations or
exclusions of this limited warranty will not constitute a waiver of such terms, limitations or exclusions,
nor will such assistance extend or revive the warranty.
The Company will not reimburse you for any expenses incurred by you in repairing or replacing any
defective Product, except for those incurred with the Company’s prior written permission.
How to Obtain Warranty Service: To qualify for warranty service, you must (a)notify the Company
at the address or telephone number stated below within seven (7)days of discovering the covered
defect, (b)give the model number and part identification and (c)describe the nature of any defect
in the Product or part. At the time of requesting warranty service, you must present evidence of the
original purchase date. If you cannot provide a copy of the original written limited warranty, then
the terms of the Company’s most current written limited warranty for your particular product will
control.The most current limited written warranties for the Company’s products can be found at
www.nutone.com.
Broan-NuTone LLC 926 West State Street, Hartford, WI 53027 www.nutone.com 800-637-1453
EZ80N
EZ Fit
Ventilador de bajo perfil
GUÍA DE INSTALACIÓN
LEA Y CONSERVE ESTAS INSTRUCCIONES
Aviso al instalador: Deje esta guía con el dueño de la casa.
Registre su producto en línea en www.nutone.com/register.
Instalación sencilla
Índice
Advertencias y precauciones 10
Funcionamiento 10
Limpieza y mantenimiento 10
Resolución de problemas 10
Instalación típica 10
Instalación 11-15
Piezas de servicio 16
Garantía 16
© 2013 Broan-NuTone LLC
EZ80N
n
Guía de instalación
Página 10
ADVERTENCIA
PARA REDUCIR EL RIESGO DE INCENDIOS, DESCARGAS
ELÉCTRICAS O LESIONES PERSONALES, SIGA LAS
SIGUIENTES PRECAUCIONES:
1. Use la unidad solo de la manera indicada por el fabricante. Si
tiene preguntas, comuníquese con el fabricante a la dirección o
al número telefónico que se incluye en la garantía.
2. Antes de dar servicio a la unidad o de limpiarla, interrumpa el
suministro eléctrico en el panel de servicio y bloquee los medios
de desconexión del servicio para evitar que la electricidad se
reanude accidentalmente. Cuando no sea posible bloquear
los medios de desconexión del servicio, fije firmemente una
señal de advertencia (como una etiqueta) en un lugar visible
del panel de servicio.
3. El trabajo de instalación y el cableado eléctrico deben estar a
cargo de personal capacitado, de acuerdo con todos los códigos
y normas correspondientes, incluidos los códigos y las normas
de construcción específicos sobre protección contraincendios.
4. Es necesario suficiente aire para que se lleve a cabo una
combustión y una extracción adecuadas de los gases a
través del tubo de humos (chimenea) del equipo quemador
de combustible, con el fin de evitar el contratiro. Siga las
directrices y las normas de seguridad del fabricante del equipo
de calefacción, como las publicadas por la Asociación Nacional
de Protección contra Incendios (National Fire Protection
Association, NFPA), la Sociedad Americana de Ingenieros de
Calefacción, Refrigeración y Aire Acondicionado (American
Society for Heating, Refrigeration and Air Conditioning
Engineers, ASHRAE) y las autoridades normativas locales.
5. Al cortar o perforar a través del cielo raso, tenga cuidado de no
dañar el cableado eléctrico ni otros serviciosocultos.
6. Los ventiladores con conductos siempre deben ventearse hacia
el exterior.
7. Esta unidad puede instalarse sobre una tina o ducha (solamente
en el cielo raso) siempre que se conecte a un GFCI (interruptor
accionado por pérdida de conexión a tierra) en un circuito de
derivación protegido.
8. Esta unidad debe estar conectada a tierra.
PRECAUCIÓN
1. Solo para usarse como medio de ventilación general. No debe
usarse para la extracción de materiales o vapores peligrosos
oexplosivos.
2. NO instale esta unidad en un panel acústico para cielo raso.
3. Cuando se instale en un cielo raso con inclinación, el conector
del conducto debe apuntar hacia arriba.
4. Para evitar daños a los cojinetes del motor y rotores ruidosos
o desbalanceados, mantenga la unidad de potencia protegida
contra rociados de yeso, polvos de construcción, etc.
5. Lea la etiqueta de especificaciones del producto para ver
información y requisitos adicionales.
45° 45°
NO USAR EL PRODUCTO EN UN ÁREA DE COCINA
No instale el equipo sobre o dentro de esta área
Piso
Equipo
decocina
*Se compra por
separado
AISLAMIENTO*
(Colóquelo alrededor
y sobre la cubierta
delventilador)
TAPA DE TECHO*
(con regulador de
tiro integrado)
CUBIERTA DEL
VENTILADOR
CABLE
ELÉCTRICO*
CONDUCTO
REDONDO*
CODOS
REDONDOS*
Selle las
separaciones
alrededor de
lacubierta
Selle con cinta
las uniones de
los conductos
OR
Mantenga cortos
los tramos de
conductos
TAPA DE PARED*
(con regulador de
tiro integrado)
SE MUESTRA LA INSTALACIÓN EN EL CIELO RASO
Funcionamiento
Para hacer funcionar el ventilador
Accione este ventilador mediante un interruptor de encendido/
apagado o control de velocidad.
ADVERTENCIA Antes de dar servicio a la
unidad o de limpiarla, interrumpa el suministro eléctrico en
el panel de servicio y bloquee los medios de desconexión
del servicio para evitar que la electricidad se reanude
accidentalmente. Cuando no sea posible bloquear los medios
de desconexión del servicio, fije firmemente una señal de
advertencia (como una etiqueta) en un lugar visible del panel de
servicio.
Limpieza y mantenimiento
Para limpiarlo
Para lograr un funcionamiento silencioso y eficiente, además
de una larga vida útil y una apariencia atractiva, retire la rejilla y
aspire el interior de la unidad con un accesorio del cepillo para
quitar el polvo.
El motor está permanentemente lubricado y nunca necesitará
ponerle aceite. Si los cojinetes del motor realizan ruidos excesivos
o inusuales, reemplace elmotor.
Resolución de problemas
Síntoma: El ventilador no funciona.
• Compruebesihayunfusibleouninterruptorautomáticoabierto
en el panel de servicio del edificio.
• Compruebequelaconexiónenchufableparaelmotorestá
asentada firmemente en su lugar.
• Compruebequelaruedadelventiladorgiresinobstrucciones.
Síntoma: El ventilador funciona de forma errática.
• Compruebequelaruedadelventiladorestéfirmemente
acoplada al eje del motor y que ambos giren sin obstrucciones.
Síntoma: El ventilador hace demasiado ruido.
• Compruebequeelreguladordetiroinvertidodelconectorde
conductos del ventilador gire sin obstrucciones. Los tornillos
utilizados para afianzar elconducto al conector de conductos
pueden impedir que se abra el regulador de tiro.
• Compruebequeelreguladordetiroinvertidodelconector
de conductos de la tapa de techo o de pared gire sin
obstrucciones. Estos reguladores suelen cerrarse
accidentalmente después de ser pintados o suelen obstruirse
con pájaros o restos de insectos.
EZ80N
n
Guía de instalación
Página 11
Retire la plantilla
del empaque.
Proceda con
elpaso 3.
Instalación - Vuelva a colocar el ventilador existente
Herramientas necesarias
• DestornilladorPhillips(recomendado)
• Martillo
• Gafasdeseguridad
• Lápiz
• Cintamétrica
• Sierraparaplacadeyeso
Materiales necesarios
• Serecomiendautilizarconductosmetálicosredondosde4pulg.
(10.2 cm) para obtener un desempeño óptimo. Aunque el uso
de otros sistemas de conductos es aceptable, puede afectar
eldesempeño.
• Tapadetechootapadepared(serecomiendaquetenga
regulador de tiro integrado)
• Cintaparasellarlasconexionesdelosconductos
• Tornillosparaplacadeyeso,tornillosdechapametálica
(opcionales)
• Cableadoeléctricoysuministrossegúnlosrequisitosdelos
códigos locales
1
Saque todo del empaque
2
Prepare la cubierta
Afloje 2 tornillos
del ventilador.
Desconecte
el ventilador
y sáquelo de
lacubierta.
1
2
3
Quite la cubierta del
cableado.
EZ80N
n
Guía de instalación
Página 12
Instalación - Vuelva a colocar el ventilador existente
3
Marque el cielo raso usando la plantilla
C
L
LÍNEA CENTRAL
DE INSTALACIÓN
UBICACIÓN DEL CONECTOR
DE CONDUCTO DEL
VENTILADOR NUEVO
Para instalaciones de conversión: Coloque este borde contra la
estructura del cielo raso.
(Consulte la sección Instrucciones de instalación).
C
L
LÍNEA CENTRAL
DE INSTALACIÓN
UBICACIÓN DEL CONECTOR
DE CONDUCTO DEL
VENTILADOR NUEVO
Para instalaciones de conversión: Coloque este borde contra la
estructura del cielo raso.
(Consulte la sección Instrucciones de instalación).
Asegúrese
de que el
ventilador
existente no
sea mayor
de 8 x 8 ¼
pulg. (20.3 x
20.9 cm).
1
Coloque la
plantilla sobre el
ventilador existente
con la flecha sobre
lalínea central.
2
3
Con un lápiz, marque
el contorno exterior de
la plantilla.
1
Utilice una sierra para placa de
yeso para cortar el material del
cielo raso donde está marcado.
ADVERTENCIA
Tenga cuidado de no cortar
através del cableado eléctrico
olos conductos.
2
Desconecte el cableado eléctrico
y los conductos, y luego quite el
ventilador existente.
4
Corte la abertura para el cielo raso y quite el ventilador usado
VIGUETA
VIGUETA
VIGUETA
VIGUETA
EZ80N
n
Guía de instalación
Página 13
Instalación - Vuelva a colocar el ventilador existente
5
Instale la cubierta nueva
Levante la cubierta
delnuevo ventilador
hacia el rectángulo
alargado en el material
del cieloraso.
Sostenga la cubierta
firmemente contra el
cielo raso y apriete
con cuidado las
4abrazaderas con un
destornillador Phillips.
Cuando se les da vuelta a la derecha (con un destornillador
Phillips), las abrazaderas girarán hacia afuera de la cubierta y se
moverán hacia abajo en la parte superior del material del cielo
raso para asegurar la cubierta ensu lugar correctamente. Techos
de un grosor mínimo deberá ser de 1/2 pulg. (1.3 cm).
NOTA: No apriete las abrazaderas excesivamente con un
destornillador eléctrico. Elmaterial del cielo raso podría
deformarse y prevenir lainstalaciónadecuada.
1
Ajuste un conducto de 4 pulg. (10 cm) en la
cubierta y utilice cinta para conductos para fijarlo
al conector de conductos de 4 pulg. (10 cm). Es
posible que tenga que cortar el conducto rígido a
la medida antes de instalar la cubierta.
Para conductos de 3 pulg. (7.6 cm), utilice
el reductor de 4 a 3 pulg. (10.2 a 7.6 cm)
(suministrado). Veaabajo.
2
Coloque un conector de conductos
de 4 pulg. (10 cm) en la abertura y
fíjelo a la cubierta con la lengüeta y
el tornillo que se proporcionan.
É
É
Reductor de
4 a 3 pulg.
(10.2 a 7.6 cm)
(suministrado)
Conductos de
3pulg. (7.6 cm)
Cinta
Cinta
Conector de
conductos de
4pulg. (10.2 cm)
6
Conecte los conductos
EZ80N
n
Guía de instalación
Página 14
Instalación - Vuelva a colocar el ventilador existente
LÍNEA DE
ENTRADA
DE 120 VCA
TIERRA
BLANCO
NEGRO
TIERRA
BLANCO
NEGRO NEGRO
BLANCO
UNIDADCAJA DEL INTERRUPTOR
INTERRUPTOR
DE ENCENDIDO/
APAGADO
M
INTERRUPTOR DE
ENCENDIDO/APAGADO
(se compra por separado)
PLACA DE
AGUJERO
CIEGO
RECEPTÁCULO
LÍNEA DE ENTRADA DE 120 VCA
CAJA
DEL
INTERRUPTOR
NEGRO
BLANCO
TIERRA (verde o sin aislamiento)
Conecte los cables de la casa
a la placa de cables con un
conector aprobado por UL.
Conecte los cables tal como
se ilustra en losdiagramas.
Conecte la placa de cables
y la cubierta de cables al
interior de lacubierta con los
tornillos suministrados.
Conecte el
ventilador en
el receptáculo
y reinstale
el ventilador.
Apriete los
tornillos del
ventilador.
7
Conecte los cables eléctricos
8
Vuelva a colocar elventilador
ADVERTENCIA
PARA REDUCIR EL RIESGO DE INCENDIOS, DESCARGAS
ELÉCTRICAS O LESIONES PERSONALES OBSERVE LAS
SIGUIENTES PRECAUCIONES: Si no está familiarizado con
el cableado eléctrico, contrate los servicios de una persona
calificada para realizar las conexiones eléctricas de acuerdo con
todos los códigos y normas aplicables.
9
Instale la rejilla
Comprima
los resortes
de la rejilla e
introdúzcalos
enlas ranuras
del ventilador.
1
Empuje la rejilla contra el cielo raso.
2
EZ80N
n
Guía de instalación
Página 15
Instalación en la nueva construcción
3
Instale la cubierta del ventilador y conecte los conductos
Utilice cinta para conductos para conectar los conductos
de 4 pulg. (10.2 cm) al conector de conductos de 4 pulg.
(10.2 cm).
Para conductos de 3 pulg. (7.6 cm), utilice el reductor de 4
a 3 pulg. (10.2 a 7.6 cm) (suministrado). Vea abajo.
4
3
Coloque el ventilador contra el armazón, con el borde
inferior de la cubierta a nivel con el cielo raso terminado.
Use 4 tornillos para fijar la cubierta al armazón.
Opcional para un soporte adicional: Una vez que el
cielo raso esté terminado, gire las abrazaderas de apriete
como se describe en el paso 5.
En una construcción nueva (antes de que esté
terminado el cielo raso):
Fije la cubierta a las viguetas del cielo raso de 2 x 6 pulg.
(5 x 15.2 cm) o mayores. Utilice bloques adicionales
según sea necesario.
1
Saque todo del empaque (Vea página 11)
2
Prepare la cubierta (Vea página 11)
2
4
Vea “Conecte los cables eléctricos” en la página 14.
5
Vea “Vuelva a colocar elventilador” en la página 14.
6
Vea “Instale la rejilla” en la página 14.
Empuje el conector
deconductos de4
pulg. (10.2cm)
hacia la abertura
y sujételo a la
cubierta con
la lengüeta
y el tornillo
suministrados.
É
É
Reductor de
4 a 3 pulg.
(10.2 a 7.6 cm)
(suministrado)
Conductos de
3pulg. (7.6 cm)
Cinta
Cinta
Conector de
conductos de
4pulg. (10.2 cm)
1
BLOQUES ADICIONALES
VIGAS
EN “I”
VIGAS
CERCHAS
EZ80N
n
Guía de instalación
Página 16
Piezas de servicio
Pida las piezas por número de pieza, no por número de clave.
N.º de clave N.º de pieza Descripción
1 79110158 Reductor de 4 a 3 pulg.
(10.2 a 7.6 cm)
2 97019326 Placa de cableado
3 77001297 Condensador
4 77001447 Abrazaderas para apretar
(incluye 4 tornillos y
abrazaderas)
5 97019006
Conjunto de la cubierta
para los cables
6 77001277 Conjunto del conector
de conductos
7 97019349 Conjunto del ventilador
8 79140014 Muelle de la rejilla
(se incluyen 2)
9 97019525 Conjunto de la rejilla
(incluye 2 muelles de rejilla)
Garantía
99045222A
1
2
3
5
6
7
9
4
8
Garantía limitada
Periodo y exclusiones de la garantía: Broan-NuTone LLC (la “Compañía”) garantiza al consumidor comprador
original de su producto (“usted”) que el producto (el “Producto”) estará libre de defectos en materiales o en mano
de obra, por un periodo de un (1) año a partir de la fecha de compra original.
El periodo de garantía limitada para cualquier pieza de repuesto proporcionada por la compañía y para cualquier
Producto reparado o reemplazado bajo esta garantía limitada debe ser lo que reste del periodo de garantía original.
Esta garantía no cubre controles de velocidad, arrancadores de lámparas fluorescentes, tubos, bombillas de
halógeno e incandescentes, fusibles, filtros, conductos, tapas de techo, tapas de pared ni otros accesorios
que pudieran ser comprados por separado e instalados con el producto. Esta garantía tampoco cubre (a)
mantenimiento y servicio normal, (b) uso y desgaste normal, (c) Productos o piezas sujetos a mal uso, abuso, uso
anormal, negligencia, accidente, mantenimiento inadecuado o insuficiente, almacenamiento o reparación (que no
sea reparación por parte de la Compañía), (d) daños causados por instalación defectuosa, o bien instalación o
uso contrario a las recomendaciones o instrucciones, (e) cualquier Producto que se haya movido de su punto de
instalación original, (f) daños ocasionados por el medio ambiente o los elementos naturales, (g) daños en tránsito,
(h) desgaste natural del acabado, (i) Productos en uso comercial o no residencial, o (j) daños ocasionados por
incendio, inundación u otro caso fortuito. Esta garantía cubre solamente Productos vendidos a clientes originales
en los Estados Unidos por la Compañía o a distribuidores de EE. UU. autorizados por la Compañía.
Esta garantía sustituye todas las garantías anteriores y no es transferible del comprador consumidor original.
No hay otras garantías: Esta garantía limitada contiene la única obligación de la Compañía y su único recurso
ante productos defectuosos. Las garantías anteriores son exclusivas y en lugar de cualquier otra garantía, expresa
o implícita. LA COMPAÑÍA NIEGA Y EXCLUYE CUALQUIER OTRA GARANTÍA EXPRESA, Y NIEGA Y EXCLUYE
TODAS LAS GARANTÍAS IMPLÍCITAS POR LEY, INCLUYENDO, ENTRE OTRAS, LAS DE COMERCIALIZACIÓN Y
APTITUD PARA UN PROPÓSITO EN PARTICULAR. Hasta el grado en que la ley aplicable prohíba la exclusión de
las garantías implícitas, la duración de cualquier garantía implícita aplicable está limitada al periodo especificado
para la garantía expresa antes mencionada. Algunos estados no permiten limitaciones en la duración de una
garantía implícita, así que la limitación anterior tal vez no aplique en su caso. Cualquier descripción verbal o escrita
del Producto es para el único propósito de identificarlo y no deberá considerarse como una garantía expresa.
Siempre que sea posible, toda disposición de esta garantía limitada deberá ser interpretada de tal forma que
sea efectiva y válida de conformidad con la ley aplicable, pero si alguna disposición fuera considerada prohibida
o inválida, quedará sin efecto solo en virtud de dicha prohibición o invalidez, sin invalidar el resto de dicha
disposición o las demás disposiciones restantes de la garantía limitada.
Recurso: Durante el periodo de garantía limitada aplicable, la Compañía, a su opción, suministrará piezas de
repuesto, o reparará o reemplazará, sin cargo alguno, cualquier Producto o pieza del mismo, hasta el grado en que
la Compañía lo encuentre cubierto bajo esta garantía limitada y en incumplimiento de la misma en condiciones
normales de uso y servicio. La Compañía le enviará el Producto reparado o reemplazado o las piezas de repuesto
sin cargo. Usted es responsable de todos los costos de retiro, reinstalación y envío, seguro u otros cargos de flete
incurridos en el envío del Producto o pieza a la Compañía. Si debe enviar el Producto o la pieza a la Compañía,
tal como lo indique la Compañía, debe empaquetar adecuadamente el Producto o la pieza: la Compañía no se
hace responsable por los daños en tránsito. La Compañía se reserva el derecho de utilizar Productos o piezas
reacondicionados, renovados, reparados o refabricados en el proceso de reemplazo o reparación de garantía.
Dichos Productos y piezas serán comparables en función y desempeño a un Producto o una pieza original y
tendrán garantía durante el resto del periodo de la garantía original.
Exclusión de daños: LA OBLIGACIÓN DE LA COMPAÑÍA DE SUMINISTRAR PIEZAS DE REPUESTO, O DE
REPARAR O REEMPLAZAR, A OPCIÓN DE LA COMPAÑÍA, SERÁ SU ÚNICO Y EXCLUSIVO RECURSO BAJO
ESTA GARANTÍA LIMITADA, Y LA ÚNICA Y EXCLUSIVA OBLIGACIÓN DE LA COMPAÑÍA. LA COMPAÑÍA NO
SERÁ RESPONSABLE POR DAÑOS INCIDENTALES, INDIRECTOS, RESULTANTES O ESPECIALES QUE SURJAN
POR EL USO O DESEMPEÑO DEL PRODUCTO, O EN RELACIÓN CON EL MISMO.
Algunos estados no permiten la exclusión o limitación de daños incidentales o resultantes, por lo que la limitación
antes mencionada podría no aplicarse a usted. Esta garantía le otorga derechos legales específicos, y usted podría
tener otros derechos que varían de un estado a otro.
Esta garantía cubre únicamente el reemplazo o la reparación de Productos defectuosos o piezas de los mismos
en la planta principal de la Compañía, y no incluye el costo del viaje para el servicio de campo ni los viáticos.
Cualquier asistencia que proporcione o procure la Compañía para usted fuera de los términos, limitaciones o
exclusiones de esta garantía limitada no constituirá una renuncia a dichos términos, limitaciones o exclusiones, ni
dicha asistencia extenderá o renovará la garantía.
La Compañía no le reembolsará ningún gasto en el que usted haya incurrido al reparar o reemplazar cualquier
Producto defectuoso, excepto los incurridos con el permiso previo por escrito de la Compañía.
Cómo obtener el servicio cubierto por la garantía: Para tener derecho al servicio cubierto por la garantía, usted
debe (a) notificar a la Compañía a la dirección o número de teléfono que aparecen abajo en un plazo de siete
(7) días después de descubrir el defecto cubierto, (b) proporcionar el número de modelo y la identificación de
la pieza y (c) describir la naturaleza de cualquier defecto en el Producto o la pieza. En el momento de solicitar
el servicio cubierto por la garantía, debe presentar un comprobante de la fecha de compra original. Si usted no
puede presentar una copia de la garantía limitada original por escrito, entonces regirán los términos de la garantía
limitada por escrito más actualizada de la compañía para su producto en particular. Las garantías limitadas por
escrito más actualizadas para los productos de la Compañía se pueden encontrar en www.nutone.com.
Broan-NuTone LLC 926 West State Street, Hartford, WI 53027 www.nutone.com 800-637-1453

Transcripción de documentos

READ AND SAVE THESE INSTRUCTIONS Installer: leave this guide with homeowner. Register your product online at www.nutone.com/register. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE Table of Contents Easy installation © 2013 Broan-NuTone LLC Warnings and Cautions Operation Cleaning and Maintenance Troubleshooting Typical Installation Installation - Replace an Existing Fan Installation in New Construction Service Parts Warranty 2 2 2 2 2 3-7 7 8 8 Page 2 EZ80N n Installation Guide Operation WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. 5. When cutting or drilling into a ceiling, do not damage electrical wiring and other hidden utilities. 6. Ducted fans must always be vented to the outdoors. 7. Acceptable for use over a tub or shower (in the ceiling only) when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit. 8. This unit must be grounded. CAUTION 1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 2. DO NOT install this unit onto an acoustic ceiling panel. 3. When installed in a sloped ceiling, the duct connector must point up. 4. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 5. Please read specification label on product for further information and requirements. NOT FOR USE IN A COOKING AREA Do not install above or inside this area 45° 45° Cooking Equipment To Operate Fan Use an ON/OFF switch or speed control to operate this ventilator. WARNING Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. Cleaning and Maintenance To Clean For quiet and efficient operation, long life and attractive appearance, remove Grille and vacuum interior of unit with a dusting brush attachment. The Motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the Motor. Troubleshooting Symptom: The fan does not run. • Check for an open fuse or circuit breaker in the building’s service panel. • Check that the plug-in connection for the Motor is seated firmly in place. • Check that the Blower Wheel spins freely. Symptom: The fan runs erratically. • Check that the Blower Wheel is firmly attached to the Motor shaft and both spin freely. Symptom: The fan seems noisy. • Check that the back draft damper in the fan’s Duct Connector pivots freely. Screws used to attach the ducting to the Duct Connector may be preventing the damper from opening. • Check that the back draft damper in the wall or roof cap pivots freely. These dampers are sometimes mistakenly painted shut or obstructed by bird and insect debris. Typical Installation INSULATION* (Place around and over Fan Housing.) ROOF CAP* (with built-in damper) FAN HOUSING Keep duct runs short. POWER CABLE* Seal gaps around Housing. ROUND DUCT* *Purchase separately. OR Seal duct joints with tape. ROUND ELBOWS* CEILING INSTALLATION SHOWN Floor WALL CAP* (with built-in damper) Page 3 EZ80N n Installation Guide Installation - Replace an Existing Fan Tools needed Materials needed • • • • • • • 4" round metal ducting recommended for best performance. Use of other ducting is acceptable but may impact performance. Phillips screwdriver (recommended) Hammer Safety glasses Pencil Tape Measure Drywall saw • Roof cap or wall cap (built-in damper recommended) • Tape to seal duct connections • Drywall screws, sheet metal screws (optional) • Electrical wiring and supplies per local code requirements 1 Remove from Packaging Punch out Template from packaging. See Step 3. 2 Prepare the Housing 2 1 Loosen 2 blower screws. Unplug blower and remove blower from housing. 3 Remove wiring cover. Page 4 EZ80N n Installation Guide Installation - Replace an Existing Fan 3 Mark Ceiling Using Template IST 1 8¼ JO IST ” Make sure existing fan is no larger than 8” x 8¼”. JO M 8” M A X . . X A 2 CL g. min O C F EN IN T S E TA R L LI L N A E T IO N fra 4 Position template over existing fan with arrow on center line. ” Cut Ceiling Opening & Remove Old Fan IST JO 1 Trace around outside of template with a pencil. 10 ¾ LO U N CA C E T T W IO C F N O A O N N F N ’S E C TO R 4 D 3 OF S OR N IO AN’ ECT T F N CA LO NEWCON CT U D ” rofi ret it rof ret E N LINATIO R TE ALL N T CE INS OF t ins ¼ 12 st t in r Fo r Fo m fra C L ing il ce st ain s.) ag n ge tio ed truc ins his ion et t lac talla s :P ns e in io e t a (S all Mark center line of existing fan on ceiling. . ing ing il ce st ain s.) ag n ge tio ed truc s in n his e t atio ll lac : P insta ns tio (See a all Use a drywall saw to cut out ceiling material where marked. WARNING Be careful to avoid cutting through electrical wiring or ductwork. IST JO 2 Disconnect electrical wiring and ductwork then remove existing fan. Page 5 EZ80N n Installation Guide Installation - Replace an Existing Fan 5 1 Install New Housing Lift new fan housing up into enlarged rectangle in ceiling material. Hold housing firmly up against ceiling material and carefully tighten 4 clamps with a Phillips screwdriver. 2 When turned clockwise (with a Phillips screwdriver), clamps will spin outward from housing and move downward on top of ceiling material to properly secure housing in place. Minimum ceiling thickness to be 1/2”. NOTE: Do not overtighten clamps with a power driver. Ceiling material may become deformed and prevent proper installation. 6 Connect Ductwork 1 Adjust 4” ductwork into housing and use duct tape to attach it to 4” duct connector. Rigid duct may have to be cut to fit prior to housing installation. For 3” ductwork, use the 4” to 3” reducer (provided). See below. 3" Ducting 2 Put 4” duct connector into opening and fasten to housing with tab and screw provided. É É Tape 4" to 3" Reducer (provided) Tape 4" Duct Connector Page 6 EZ80N n Installation Guide Installation - Replace an Existing Fan 7 WARNING Connect Electrical Wiring 9 Install Grille TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: If unfamiliar with electrical wiring, secure the services of a qualified person to connect wiring according to all applicable codes and standards. Connect house wiring to wiring plate with UL approved connector. Connect wiring as shown in diagrams. Attach wiring plate and wiring cover to inside of housing with screws provided. BLK 1 Squeeze grille springs and insert into slots in blower. BLK ON/OFF SWITCH M WHT BLK 120 VAC WHT LINE IN GRD WHT GRD SWITCH BOX BLACK WHITE ON/OFF SWITCH (purchase separately) UNIT GROUND (green or bare) RECEPTACLE SWITCH BOX KNOCKOUT PLATE 120 VAC LINE IN 8 Replace Blower 2 Plug blower into receptacle and re-install blower. Tighten blower screws. Push grille up against ceiling. Page 7 EZ80N n Installation Guide Installation in New Construction 1 Remove from Packaging (See Page 3) Prepare the Housing (See Page 3) 2 3 Install Fan Housing & Connect Ductwork 1 Push 4” duct connector into opening and fasten to housing with tab and screw provided. 2 In new construction (before ceiling is finished): 3 Position fan against ceiling framing with bottom edge of housing flush with finished ceiling. Use 4 screws to attach housing to framing. Optional for additional support: After ceiling is finished, rotate the tightening clamps as described in Step 5. 4 Use duct tape to connect 4” ductwork to 4” duct connector. For 3” ductwork, use the 4” to 3” reducer (provided). See below. Tape Tape Attach housing to 2" x 6" or greater ceiling joists. Use additional blocking as needed. I-JOISTS TRUSSES É É JOISTS 4" Duct Connector 3" Ducting ADDITIONAL BLOCKING 4 See “Connect Electrical Wiring” on Page 6. See “Replace Blower” on Page 6. 5 See “Install Grille” on Page 6. 6 4" to 3" Reducer (provided) Page 8 EZ80N n Installation Guide Service Parts Warranty 1 2 3 4 6 5 7 8 9 Key No. Part No. 1 2 3 4 79110158 97019326 77001297 77001447 5 6 7 8 9 97019006 77001277 97019349 79140014 97019525 Description 4” to 3” Reducer Wiring Plate Capacitor Tightening Clamps (includes 4 screws & clamps) Wire Cover Assembly Duct Connector Assembly Blower Assembly Grille Spring (2 included) Grille Assembly (includes 2 grille springs) Order replacement parts by Part No., not by Key No. Limited Warranty Warranty Period and Exclusions: Broan-NuTone LLC (the “Company”) warrants to the original consumer purchaser of its product (“you”) that the product (the “Product”) will be free from material defects in the Product or its workmanship for a period of one (1) year from the date of original purchase. The limited warranty period for any replacement parts provided by the Company and for any Products repaired or replaced under this limited warranty shall be the remainder of the original warranty period. This warranty does not cover speed controls, fluorescent lamp starters, tubes, halogen and incandescent bulbs, fuses, filters, ducts, roof caps, wall caps and other accessories for ducting that may be purchased separately and installed with the Product. This warranty also does not cover (a)  normal maintenance and service, (b)  normal wear and tear, (c)  any Products or parts which have been subject to misuse, abuse, abnormal usage, negligence, accident, improper or insufficient maintenance, storage or repair (other than repair by the Company), (d)  damage caused by faulty installation, or installation or use contrary to recommendations or instructions, (e)  any Product that has been moved from its original point of installation, (f)  damage caused by environmental or natural elements, (g)  damage in transit, (h)  natural wear of finish, (i)  Products in commercial or nonresidential use, or (j) damage caused by fire, flood or other act of God. This warranty covers only Products sold to original consumers in the United States by the Company or U.S. distributors authorized by the Company. This warranty supersedes all prior warranties and is not transferable from the original consumer purchaser. No Other Warranties: This Limited Warranty contains the Company’s sole obligation and your sole remedy for defective products. The foregoing warranties are exclusive and in lieu of any other warranties, express or implied. THE COMPANY DISCLAIMS AND EXCLUDES ALL OTHER EXPRESS WARRANTIES, AND DISCLAIMS AND EXCLUDES ALL WARRANTIES IMPLIED BY LAW, INCLUDING WITHOUT LIMITATION THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. To the extent that applicable law prohibits the exclusion of implied warranties, the duration of any applicable implied warranty is limited to the period specified for the express warranty above. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Any oral or written description of the Product is for the sole purpose of identifying it and shall not be construed as an express warranty. Whenever possible, each provision of this Limited Warranty shall be interpreted in such manner as to be effective and valid under applicable law, but if any provision is held to be prohibited or invalid, such provision shall be ineffective only to the extent of such prohibition or invalidity, without invalidating the remainder of such provision or the other remaining provisions of the Limited Warranty. Remedy: During the applicable limited warranty period, the Company will, at its option, provide replacement parts for, or repair or replace, without charge, any Product or part thereof, to the extent the Company finds it to be covered by and in breach of this limited warranty under normal use and service. The Company will ship the repaired or replaced Product or replacement parts to you at no charge. You are responsible for all costs for removal, reinstallation and shipping, insurance or other freight charges incurred in the shipment of the Product or part to the Company. If you must send the Product or part to the Company, as instructed by the Company, you must properly pack the Product or part—the Company is not responsible for damage in transit. The Company reserves the right to utilize reconditioned, refurbished, repaired or remanufactured Products or parts in the warranty repair or replacement process. Such Products and parts will be comparable in function and performance to an original Product or part and warranted for the remainder of the original warranty period. Exclusion of Damages: THE COMPANY’S OBLIGATION TO PROVIDE REPLACEMENT PARTS, OR REPAIR OR REPLACE, AT THE COMPANY’S OPTION, SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY AND THE COMPANY’S SOLE AND EXCLUSIVE OBLIGATION. THE COMPANY SHALL NOT BE LIABLE FOR INCIDENTAL, INDIRECT, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE PRODUCT, ITS USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty covers only replacement or repair of defective Products or parts thereof at the Company’s main facility and does not include the cost of field service travel and living expenses. Any assistance the Company provides to or procures for you outside the terms, limitations or exclusions of this limited warranty will not constitute a waiver of such terms, limitations or exclusions, nor will such assistance extend or revive the warranty. The Company will not reimburse you for any expenses incurred by you in repairing or replacing any defective Product, except for those incurred with the Company’s prior written permission. How to Obtain Warranty Service: To qualify for warranty service, you must (a) notify the Company at the address or telephone number stated below within seven (7) days of discovering the covered defect, (b) give the model number and part identification and (c) describe the nature of any defect in the Product or part. At the time of requesting warranty service, you must present evidence of the original purchase date. If you cannot provide a copy of the original written limited warranty, then the terms of the Company’s most current written limited warranty for your particular product will control.  The most current limited written warranties for the Company’s products can be found at www.nutone.com. Broan-NuTone LLC 926 West State Street, Hartford, WI 53027 www.nutone.com 800-637-1453 99045222A LEA Y CONSERVE ESTAS INSTRUCCIONES Aviso al instalador: Deje esta guía con el dueño de la casa. Registre su producto en línea en www.nutone.com/register. EZ80N EZ Fit Ventilador de bajo perfil GUÍA DE INSTALACIÓN Índice Instalación sencilla © 2013 Broan-NuTone LLC Advertencias y precauciones Funcionamiento Limpieza y mantenimiento Resolución de problemas Instalación típica Instalación Piezas de servicio Garantía 10 10 10 10 10 11-15 16 16 Página 10 EZ80N n Guía de instalación ADVERTENCIA Funcionamiento PARA REDUCIR EL RIESGO DE INCENDIOS, DESCARGAS ELÉCTRICAS O LESIONES PERSONALES, SIGA LAS SIGUIENTES PRECAUCIONES: 1. Use la unidad solo de la manera indicada por el fabricante. Si tiene preguntas, comuníquese con el fabricante a la dirección o al número telefónico que se incluye en la garantía. 2. Antes de dar servicio a la unidad o de limpiarla, interrumpa el suministro eléctrico en el panel de servicio y bloquee los medios de desconexión del servicio para evitar que la electricidad se reanude accidentalmente. Cuando no sea posible bloquear los medios de desconexión del servicio, fije firmemente una señal de advertencia (como una etiqueta) en un lugar visible del panel de servicio. 3. El trabajo de instalación y el cableado eléctrico deben estar a cargo de personal capacitado, de acuerdo con todos los códigos y normas correspondientes, incluidos los códigos y las normas de construcción específicos sobre protección contra incendios. 4. Es necesario suficiente aire para que se lleve a cabo una combustión y una extracción adecuadas de los gases a través del tubo de humos (chimenea) del equipo quemador de combustible, con el fin de evitar el contratiro. Siga las directrices y las normas de seguridad del fabricante del equipo de calefacción, como las publicadas por la Asociación Nacional de Protección contra Incendios (National Fire Protection Association, NFPA), la Sociedad Americana de Ingenieros de Calefacción, Refrigeración y Aire Acondicionado (American Society for Heating, Refrigeration and Air Conditioning Engineers, ASHRAE) y las autoridades normativas locales. 5. Al cortar o perforar a través del cielo raso, tenga cuidado de no dañar el cableado eléctrico ni otros servicios ocultos. 6. Los ventiladores con conductos siempre deben ventearse hacia el exterior. 7. Esta unidad puede instalarse sobre una tina o ducha (solamente en el cielo raso) siempre que se conecte a un GFCI (interruptor accionado por pérdida de conexión a tierra) en un circuito de derivación protegido. 8. Esta unidad debe estar conectada a tierra. Para hacer funcionar el ventilador Accione este ventilador mediante un interruptor de encendido/ apagado o control de velocidad. PRECAUCIÓN 1. Solo para usarse como medio de ventilación general. No debe 2. 3. 4. 5. usarse para la extracción de materiales o vapores peligrosos o explosivos. NO instale esta unidad en un panel acústico para cielo raso. Cuando se instale en un cielo raso con inclinación, el conector del conducto debe apuntar hacia arriba. Para evitar daños a los cojinetes del motor y rotores ruidosos o desbalanceados, mantenga la unidad de potencia protegida contra rociados de yeso, polvos de construcción, etc. Lea la etiqueta de especificaciones del producto para ver información y requisitos adicionales. NO USAR EL PRODUCTO EN UN ÁREA DE COCINA No instale el equipo sobre o dentro de esta área ADVERTENCIA Antes de dar servicio a la unidad o de limpiarla, interrumpa el suministro eléctrico en el panel de servicio y bloquee los medios de desconexión del servicio para evitar que la electricidad se reanude accidentalmente. Cuando no sea posible bloquear los medios de desconexión del servicio, fije firmemente una señal de advertencia (como una etiqueta) en un lugar visible del panel de servicio. Limpieza y mantenimiento Para limpiarlo Para lograr un funcionamiento silencioso y eficiente, además de una larga vida útil y una apariencia atractiva, retire la rejilla y aspire el interior de la unidad con un accesorio del cepillo para quitar el polvo. El motor está permanentemente lubricado y nunca necesitará ponerle aceite. Si los cojinetes del motor realizan ruidos excesivos o inusuales, reemplace el motor. Resolución de problemas Síntoma: El ventilador no funciona. • Compruebe si hay un fusible o un interruptor automático abierto en el panel de servicio del edificio. • Compruebe que la conexión enchufable para el motor está asentada firmemente en su lugar. • Compruebe que la rueda del ventilador gire sin obstrucciones. Síntoma: El ventilador funciona de forma errática. • Compruebe que la rueda del ventilador esté firmemente acoplada al eje del motor y que ambos giren sin obstrucciones. Síntoma: El ventilador hace demasiado ruido. • Compruebe que el regulador de tiro invertido del conector de conductos del ventilador gire sin obstrucciones. Los tornillos utilizados para afianzar el conducto al conector de conductos pueden impedir que se abra el regulador de tiro. • Compruebe que el regulador de tiro invertido del conector de conductos de la tapa de techo o de pared gire sin obstrucciones. Estos reguladores suelen cerrarse accidentalmente después de ser pintados o suelen obstruirse con pájaros o restos de insectos. AISLAMIENTO* (Colóquelo alrededor y sobre la cubierta del ventilador) CUBIERTA DEL VENTILADOR TAPA DE TECHO* (con regulador de tiro integrado) Mantenga cortos los tramos de conductos CABLE ELÉCTRICO* 45° 45° Equipo de cocina Piso Selle las separaciones alrededor de la cubierta OR CONDUCTO REDONDO* Selle con cinta las uniones de CODOS *Se compra por los conductos REDONDOS* separado TAPA DE PARED* (con regulador de tiro integrado) SE MUESTRA LA INSTALACIÓN EN EL CIELO RASO Página 11 EZ80N n Guía de instalación Instalación - Vuelva a colocar el ventilador existente Herramientas necesarias Materiales necesarios • • • • • • • S e recomienda utilizar conductos metálicos redondos de 4 pulg. (10.2 cm) para obtener un desempeño óptimo. Aunque el uso de otros sistemas de conductos es aceptable, puede afectar el desempeño. Destornillador Phillips (recomendado) Martillo Gafas de seguridad Lápiz Cinta métrica Sierra para placa de yeso • T apa de techo o tapa de pared (se recomienda que tenga regulador de tiro integrado) • Cinta para sellar las conexiones de los conductos 1 Saque todo del empaque • T ornillos para placa de yeso, tornillos de chapa metálica (opcionales) • C ableado eléctrico y suministros según los requisitos de los códigos locales Retire la plantilla del empaque. Proceda con el paso 3. 2 Prepare la cubierta 2 1 Afloje 2 tornillos del ventilador. Desconecte el ventilador y sáquelo de la cubierta. 3 Quite la cubierta del cableado. Página 12 EZ80N n Guía de instalación Instalación - Vuelva a colocar el ventilador existente 3 Marque el cielo raso usando la plantilla A ET A ET B L RA N NT CIÓ CE ALA EA ST LÍN E IN D 2 Coloque la plantilla sobre el ventilador existente con la flecha sobre la línea central. IC A D C V E IÓN E C N O D T N E IL D L A U C D C O O T N R O E N D C U EL TO E R V O la se cc L D ÍN E EA IN S CE TA N L TR A A C L IÓ N in st (C o n su lt e C L co rde bo n). te ció es so. tala ue ra ins loq cielo e o C el sd : d e ión ra ion cc ers tu tru nv uc co estr Ins de ión es cc se ion c la tala lte su ins on ra (C Pa U CL a la ntr Asegúrese de que el ventilador existente no sea mayor de 8 x 8 ¼ pulg. (20.3 x 20.9 cm). P ar a 1 al ac io n es d e co n es ve tr rs u ió ct n ió u : ra n C In d olo st el q ru ci ue cc el e io o s n ra te es so b d . or e d in e co st al n ac tr a ió la n ). U VIG U VIG 3 R TO EC L ON DE VO C L TO UE DE UC R N N IÓ ONDADO C C L ICA DE NTI UB VE Con un lápiz, marque el contorno exterior de la plantilla. 4 Corte la abertura para el cielo raso y quite el ventilador usado A ET U VIG 1 Utilice una sierra para placa de yeso para cortar el material del cielo raso donde está marcado. ADVERTENCIA Tenga cuidado de no cortar a través del cableado eléctrico o los conductos. A ET U VIG 2 Desconecte el cableado eléctrico y los conductos, y luego quite el ventilador existente. Página 13 EZ80N n Guía de instalación Instalación - Vuelva a colocar el ventilador existente 5 Instale la cubierta nueva Levante la cubierta del nuevo ventilador hacia el rectángulo alargado en el material del cielo raso. Sostenga la cubierta firmemente contra el cielo raso y apriete con cuidado las 4 abrazaderas con un destornillador Phillips. 6 Cuando se les da vuelta a la derecha (con un destornillador Phillips), las abrazaderas girarán hacia afuera de la cubierta y se moverán hacia abajo en la parte superior del material del cielo raso para asegurar la cubierta en su lugar correctamente. Techos de un grosor mínimo deberá ser de 1/2 pulg. (1.3 cm). NOTA: No apriete las abrazaderas excesivamente con un destornillador eléctrico. El material del cielo raso podría deformarse y prevenir la instalación adecuada. Conecte los conductos 1 Ajuste un conducto de 4 pulg. (10 cm) en la cubierta y utilice cinta para conductos para fijarlo al conector de conductos de 4 pulg. (10 cm). Es posible que tenga que cortar el conducto rígido a la medida antes de instalar la cubierta. Para conductos de 3 pulg. (7.6 cm), utilice el reductor de 4 a 3 pulg. (10.2 a 7.6 cm) (suministrado). Vea abajo. Conductos de 3 pulg. (7.6 cm) Coloque un conector de conductos de 4 pulg. (10 cm) en la abertura y fíjelo a la cubierta con la lengüeta y el tornillo que se proporcionan. É É Reductor de 4 a 3 pulg. (10.2 a 7.6 cm) (suministrado) Cinta 2 Cinta Conector de conductos de 4 pulg. (10.2 cm) Página 14 EZ80N n Guía de instalación Instalación - Vuelva a colocar el ventilador existente 7 Conecte los cables eléctricos ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIOS, DESCARGAS ELÉCTRICAS O LESIONES PERSONALES OBSERVE LAS SIGUIENTES PRECAUCIONES: Si no está familiarizado con el cableado eléctrico, contrate los servicios de una persona calificada para realizar las conexiones eléctricas de acuerdo con todos los códigos y normas aplicables. Conecte los cables de la casa a la placa de cables con un conector aprobado por UL. Conecte los cables tal como se ilustra en los diagramas. Conecte la placa de cables y la cubierta de cables al interior de la cubierta con los tornillos suministrados. NEGRO M Comprima los resortes de la rejilla e introdúzcalos en las ranuras del ventilador. BLANCO BLANCO TIERRA CAJA DEL INTERRUPTOR NEGRO BLANCO 1 NEGRO INTERRUPTOR DE ENCENDIDO/ APAGADO NEGRO LÍNEA DE ENTRADA BLANCO DE 120 VCA TIERRA 9 Instale la rejilla UNIDAD TIERRA (verde o sin aislamiento) RECEPTÁCULO INTERRUPTOR DE CAJA ENCENDIDO/APAGADO DEL (se compra por separado) INTERRUPTOR PLACA DE AGUJERO CIEGO LÍNEA DE ENTRADA DE 120 VCA 8 Vuelva a colocar el ventilador Conecte el ventilador en el receptáculo y reinstale el ventilador. Apriete los tornillos del ventilador. 2 Empuje la rejilla contra el cielo raso. Página 15 EZ80N n Guía de instalación Instalación en la nueva construcción 1 Prepare la cubierta (Vea página 11) 2 3 Instale la cubierta del ventilador y conecte los conductos Saque todo del empaque (Vea página 11) 1 2 Empuje el conector de conductos de 4 pulg. (10.2 cm) hacia la abertura y sujételo a la cubierta con la lengüeta y el tornillo suministrados. 3 Coloque el ventilador contra el armazón, con el borde inferior de la cubierta a nivel con el cielo raso terminado. Use 4 tornillos para fijar la cubierta al armazón. Opcional para un soporte adicional: Una vez que el cielo raso esté terminado, gire las abrazaderas de apriete como se describe en el paso 5. 4 Utilice cinta para conductos para conectar los conductos de 4 pulg. (10.2 cm) al conector de conductos de 4 pulg. (10.2 cm). Para conductos de 3 pulg. (7.6 cm), utilice el reductor de 4 a 3 pulg. (10.2 a 7.6 cm) (suministrado). Vea abajo. En una construcción nueva (antes de que esté terminado el cielo raso): Fije la cubierta a las viguetas del cielo raso de 2 x 6 pulg. (5 x 15.2 cm) o mayores. Utilice bloques adicionales según sea necesario. VIGAS VIGAS EN “I” CERCHAS BLOQUES ADICIONALES É É Cinta Conductos de 3 pulg. (7.6 cm) Reductor de 4 a 3 pulg. (10.2 a 7.6 cm) (suministrado) 4 5 Vea “Vuelva a colocar el ventilador” en la página 14. 6 Vea “Instale la rejilla” en la página 14. Vea “Conecte los cables eléctricos” en la página 14. Cinta Conector de conductos de 4 pulg. (10.2 cm) Página 16 EZ80N n Guía de instalación Piezas de servicio 1 2 3 4 6 5 7 8 9 N.º de clave N.º de pieza 1 79110158 2 3 4 97019326 77001297 77001447 5 97019006 6 77001277 7 8 97019349 79140014 9 97019525 Descripción Reductor de 4 a 3 pulg. (10.2 a 7.6 cm) Placa de cableado Condensador Abrazaderas para apretar (incluye 4 tornillos y abrazaderas) Conjunto de la cubierta para los cables Conjunto del conector de conductos Conjunto del ventilador Muelle de la rejilla (se incluyen 2) Conjunto de la rejilla (incluye 2 muelles de rejilla) Pida las piezas por número de pieza, no por número de clave. Garantía Garantía limitada Periodo y exclusiones de la garantía: Broan-NuTone LLC (la “Compañía”) garantiza al consumidor comprador original de su producto (“usted”) que el producto (el “Producto”) estará libre de defectos en materiales o en mano de obra, por un periodo de un (1) año a partir de la fecha de compra original. El periodo de garantía limitada para cualquier pieza de repuesto proporcionada por la compañía y para cualquier Producto reparado o reemplazado bajo esta garantía limitada debe ser lo que reste del periodo de garantía original. Esta garantía no cubre controles de velocidad, arrancadores de lámparas fluorescentes, tubos, bombillas de halógeno e incandescentes, fusibles, filtros, conductos, tapas de techo, tapas de pared ni otros accesorios que pudieran ser comprados por separado e instalados con el producto. Esta garantía tampoco cubre (a) mantenimiento y servicio normal, (b) uso y desgaste normal, (c) Productos o piezas sujetos a mal uso, abuso, uso anormal, negligencia, accidente, mantenimiento inadecuado o insuficiente, almacenamiento o reparación (que no sea reparación por parte de la Compañía), (d) daños causados por instalación defectuosa, o bien instalación o uso contrario a las recomendaciones o instrucciones, (e) cualquier Producto que se haya movido de su punto de instalación original, (f) daños ocasionados por el medio ambiente o los elementos naturales, (g) daños en tránsito, (h) desgaste natural del acabado, (i) Productos en uso comercial o no residencial, o (j) daños ocasionados por incendio, inundación u otro caso fortuito. Esta garantía cubre solamente Productos vendidos a clientes originales en los Estados Unidos por la Compañía o a distribuidores de EE. UU. autorizados por la Compañía. Esta garantía sustituye todas las garantías anteriores y no es transferible del comprador consumidor original. No hay otras garantías: Esta garantía limitada contiene la única obligación de la Compañía y su único recurso ante productos defectuosos. Las garantías anteriores son exclusivas y en lugar de cualquier otra garantía, expresa o implícita. LA COMPAÑÍA NIEGA Y EXCLUYE CUALQUIER OTRA GARANTÍA EXPRESA, Y NIEGA Y EXCLUYE TODAS LAS GARANTÍAS IMPLÍCITAS POR LEY, INCLUYENDO, ENTRE OTRAS, LAS DE COMERCIALIZACIÓN Y APTITUD PARA UN PROPÓSITO EN PARTICULAR. Hasta el grado en que la ley aplicable prohíba la exclusión de las garantías implícitas, la duración de cualquier garantía implícita aplicable está limitada al periodo especificado para la garantía expresa antes mencionada. Algunos estados no permiten limitaciones en la duración de una garantía implícita, así que la limitación anterior tal vez no aplique en su caso. Cualquier descripción verbal o escrita del Producto es para el único propósito de identificarlo y no deberá considerarse como una garantía expresa. Siempre que sea posible, toda disposición de esta garantía limitada deberá ser interpretada de tal forma que sea efectiva y válida de conformidad con la ley aplicable, pero si alguna disposición fuera considerada prohibida o inválida, quedará sin efecto solo en virtud de dicha prohibición o invalidez, sin invalidar el resto de dicha disposición o las demás disposiciones restantes de la garantía limitada. Recurso: Durante el periodo de garantía limitada aplicable, la Compañía, a su opción, suministrará piezas de repuesto, o reparará o reemplazará, sin cargo alguno, cualquier Producto o pieza del mismo, hasta el grado en que la Compañía lo encuentre cubierto bajo esta garantía limitada y en incumplimiento de la misma en condiciones normales de uso y servicio. La Compañía le enviará el Producto reparado o reemplazado o las piezas de repuesto sin cargo. Usted es responsable de todos los costos de retiro, reinstalación y envío, seguro u otros cargos de flete incurridos en el envío del Producto o pieza a la Compañía. Si debe enviar el Producto o la pieza a la Compañía, tal como lo indique la Compañía, debe empaquetar adecuadamente el Producto o la pieza: la Compañía no se hace responsable por los daños en tránsito. La Compañía se reserva el derecho de utilizar Productos o piezas reacondicionados, renovados, reparados o refabricados en el proceso de reemplazo o reparación de garantía. Dichos Productos y piezas serán comparables en función y desempeño a un Producto o una pieza original y tendrán garantía durante el resto del periodo de la garantía original. Exclusión de daños: LA OBLIGACIÓN DE LA COMPAÑÍA DE SUMINISTRAR PIEZAS DE REPUESTO, O DE REPARAR O REEMPLAZAR, A OPCIÓN DE LA COMPAÑÍA, SERÁ SU ÚNICO Y EXCLUSIVO RECURSO BAJO ESTA GARANTÍA LIMITADA, Y LA ÚNICA Y EXCLUSIVA OBLIGACIÓN DE LA COMPAÑÍA. LA COMPAÑÍA NO SERÁ RESPONSABLE POR DAÑOS INCIDENTALES, INDIRECTOS, RESULTANTES O ESPECIALES QUE SURJAN POR EL USO O DESEMPEÑO DEL PRODUCTO, O EN RELACIÓN CON EL MISMO. Algunos estados no permiten la exclusión o limitación de daños incidentales o resultantes, por lo que la limitación antes mencionada podría no aplicarse a usted. Esta garantía le otorga derechos legales específicos, y usted podría tener otros derechos que varían de un estado a otro. Esta garantía cubre únicamente el reemplazo o la reparación de Productos defectuosos o piezas de los mismos en la planta principal de la Compañía, y no incluye el costo del viaje para el servicio de campo ni los viáticos. Cualquier asistencia que proporcione o procure la Compañía para usted fuera de los términos, limitaciones o exclusiones de esta garantía limitada no constituirá una renuncia a dichos términos, limitaciones o exclusiones, ni dicha asistencia extenderá o renovará la garantía. La Compañía no le reembolsará ningún gasto en el que usted haya incurrido al reparar o reemplazar cualquier Producto defectuoso, excepto los incurridos con el permiso previo por escrito de la Compañía. Cómo obtener el servicio cubierto por la garantía: Para tener derecho al servicio cubierto por la garantía, usted debe (a) notificar a la Compañía a la dirección o número de teléfono que aparecen abajo en un plazo de siete (7) días después de descubrir el defecto cubierto, (b) proporcionar el número de modelo y la identificación de la pieza y (c) describir la naturaleza de cualquier defecto en el Producto o la pieza. En el momento de solicitar el servicio cubierto por la garantía, debe presentar un comprobante de la fecha de compra original. Si usted no puede presentar una copia de la garantía limitada original por escrito, entonces regirán los términos de la garantía limitada por escrito más actualizada de la compañía para su producto en particular. Las garantías limitadas por escrito más actualizadas para los productos de la Compañía se pueden encontrar en www.nutone.com. Broan-NuTone LLC 926 West State Street, Hartford, WI 53027 www.nutone.com 800-637-1453 99045222A
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

NuTone EZ80N Guía de instalación

Tipo
Guía de instalación