INSTALLATION INSTRUCTIONS
Please read carefully and save these instructions. Failure to do so may lead to
electric al shock or fire, whi ch may cause injury or death.
________
CAUTION
WARNING – RISK OF FIRE: Turn off the main power at the circuit breaker before
installing the fixture, changing lamps, or performing other maintenance in order to
prevent possible shock.
_________
GENERAL
All electrical connections must be in accordance with local, and national electrical
codes.
Prior to installation it is important to follow the following guidelines:
A. Use only the type of tube light specified, with wattage not greater than
specified on the wattage label found on the fixture.
B. Remove all protective plastic film covering from the fixture.
___________________________
ASSEMBLY AND INSTALLATION
1. Turn the lock pin (A) and squeeze the channel at the markers shown to remove
the channel cover.
2. Place track assemblies into slots in the end of the channel.
3. Pull the tracks toward the end of the channel to lock into place.
4. With the power off, connect the black supply wire to the black fixture wire.
Connect the white supply wire to the white fixture wire. Connect the ground supply
wire to the green ground screw.
5. Align channel cover and push it down to snap it into place. Note: the arrow on the
label points to the end with the fixture wires.
6. Line up the T8 tube with the end marked “L & N” into the side where the arrow on
the label is pointing. Insert the lamp into the socket and rotate 90° (a quarter turn)
to lock it in place.
4-FT 1-LIGHT T8 LED INDUSTRIAL STRIP
WITH 1800 or 3500 LUMEN DLC FLEX TUBES
BLACK FIXTURE WIRE BLACK SUPPLY WIRE
WHITE FIXTURE WIRE WHITE SUPPLY WIRE
GREEN GROUND SCREW SUPPLY GROUND WIRE