Asco Series 551 Solenoid Valves Manual de usuario

Tipo
Manual de usuario
3
2
3834901
3834901
Installation and Maintenance Instructions
3/2 NC
GB
Series 551 solenoid valves, brass body, or series 551-553, stainless
steel body, 1/4“, 1/2" thread or NAMUR interface
5/2 - 5/3
DESCRIPTION OF THE APPROVAL
Versions concerned by the approval (fi g. 1 and 11):
Brass body (series 551) or stainless steel body (series
551, 553), monostable (spring return) or bistable, 3/2 NC
(normally closed) function or 5/2, version isolated from
the outside atmosphere. Versions with or without manual
override.
- with threaded 1/4 (551) or 1/2 (553) ports - 551, with ¼”
threaded connection, max. port depth 11,5 mm. - (Do not
connect the pressure supply to the exhaust port 3. The
“environmentally-protected” construction is not adapted
for a “distributing” function or use in NO function. Contact
us for functions available in specifi c versions).
- with NAMUR interface for direct mounting to single acting
(function 3/2 NC) or double acting (function 5/2) pneumatic
actuators. The function of the valve is convertible from 3/2
NC to 5/2 by mounting the supplied 3/2 NC or 5/2 interface
plate at the bottom of the valve (fi g.13a, 13b, ref. 1a and 1b).
551, max. 1/4" port depth = 11,5 mm. (
Do not connect the
pressure supply to the exhaust port 3. The “environmentally-
protected” construction is not adapted for NO function.
Contact us for functions available in specifi c versions).
Connect pipes for the required functions in accordance with
this documentation and the port markings on the product.
- Make sure no foreign matter enters the circuit to prevent
blocking the valve function. Restrict the use of sealing tape
or sealing matter to a minimum.
- These valves are intended for use with clean and dry air or
inert gas. Recommended minimum fi ltration: 50 microns. The
dew point of the fl uid used must be at least –10°C (18°F) below
the minimum temperature to which the fl uid may be exposed.
When using lubricated air, the lubricant must be compatible
with the elastomers used. Instrument air in compliance with
ANSI/ISA standard S7.3 (1975) exceeds the necessary require-
ments and is, therefore, an acceptable fl uid for these valves.
!
All exhaust ports of the valves and pilots must be
protected with the stainless steel exhaust protectors.
Connect these exhaust protectors to port 3 (3/2 NC)
or ports 3 – 5 (5/2) of the valves. When used outside, or
stored for longer periods of time, and/or where exposed
to harsh environments (dusts, liquids etc.), exhaust pro-
tectors must be used. The reliability of the valve cannot
be guaranteed if an exhaust protection other than that
supplied is used.
- Allowable temperature range:
-40°C to +80°C (series 551); -40°C to +60°C (series 553).
- Max. operating pressure range:
-2 to 10 bar
-2 to 8 bar (ISSC/PISC/PISCIS/CFSCIS/CFSDISCFVTIS)
GENERAL DESCRIPTION
ATEX 94/9/EC versions: See “Special conditions for safe use”.
Versions isolated from atmosphere: The internal parts of
the valve are isolated from the outside atmosphere in order to
provide protection in aggressive environments. All the exhaust
ports of the spool valve are pipable, providing better environ-
mental protection, particularly recommended for sensitive areas
such as clean rooms and applications in the pharmaceutical or
food processing industries. It is necessary to connect pipes or
ttings to the exhaust ports to protect the internal parts of the
spool valve if used outside or in harsh environments (dusts,
liquids etc.).
SPECIAL CONDITIONS FOR SAFE USE
ATEX 94/9/EC: The valve must be connected to ground (see
"Assembly").
The maximum fl uid temperature must not exceed the ambient
temperature.
The spool valve must be kept in its original packaging as long
as it is left unused. The protective covers must not be removed
from the connection ports and solenoid operators.
Storage conditions: protected from exposure to weather; storage
temperature: -40 C to +70°C ; relative humidity: 95 %
After storage at low temperature, the spool valves must
gradually be brought to room temperature prior to pres-
surisation.
The spool valves are intended to be operated within the techni-
cal characteristics specifi ed on the nameplate. Changes to the
equipment are only allowed after consulting the manufacturer or
its representative. These solenoid spool valves are designed
to operate with fi ltered air or neutral gas. Do not exceed the
maximum allowable pressure of the valve = 10 bar (or 8 bar with
a Piezotronic pilot valve to ATEX Ex ia). Caution: Observe the
minimum pilot pressure of 2 bar. Installation and maintenance
of the valve must be carried out by qualifi ed personnel only.
Standard IP65-rated air operated versions or versions for
use in explosive atmospheres caused by gases, vapours,
mists or dusts according to ATEX Directive 94/9/EC. (The
zone classifi cation for this version is stated on the ATEX
nameplate, ref. E1).
Safety code, series 551: II 1 GD c T6 T85°C Ta -40°C to +65°C
Safety code, series 553: II 2 GD c T6 (T85°C) - T5 (T100°C)
EC type-examination certifi cate no. (Series 551): INERIS
03 ATEX 0219 X
Compliance with the Essential Health and Safety Require-
ments has been assured by compliance with the European
Standards EN 13463-1 and EN 13463-5.
Solenoid-air operated versions tted with solenoid operators:
- IP65-rated or certifi ed for use in explosive atmospheres ac-
cording to ATEX Directive 94/9/EC.
Versions with solenoid operators with ASCO mounting
pad, IP65-rated as standard, or for use in explosive atmos-
pheres II 3D IP65/IP67 or ATEX Ex d, m, em, Ex ia (Series
551: II 1G/2D Ex ia IIC IP65/IP67 or series 553: II 2G/D Ex
ia IIC IP65/IP67).
Versions with pilots with CNOMO E06.05.80 (size
30) or CNOMO E06.36.120N (size 15) mounting pad,
IP 65-rated as standard, or mounting of pilots for use in
explosive atmospheres according to ATEX Ex d or Ex ia.
Caution (CNOMO pilots):
The zone classification
(ATEX 1999/927EC) is mainly defined by the indica-
tions on the nameplate fi g. 10 and 20 (ref. E1 or E2)
on the valve’s body. Safety code according to ATEX
Directive 94/9/EC: II 1 GD c T6 T85°C Ta -40°C to +65°C
EC type-examination certifi cate no.: INERIS 03 ATEX 0219 X
When assembling this product to a pilot to ATEX 94/9/EC,
take the least favourable category and temperature into
account. Compliance with the Essential Health and Safety
Requirements has been assured by compliance with the Eu-
ropean Standards EN 13463-1 and EN 13463-5. The mounting
position for the pilots as shown in fi gures 4/5/14/15/21/22/23/24
and the indicated tightening torques must be observed.
For solenoid operators and pilots to ATEX 94/9/EC, the
instructions for use given in the specifi c Installation Instruc-
tions provided with the product must be strictly followed.
ASSEMBLY
!
ATEX 94/9/EC versions: Make sure that all metal or
conductive parts are always interconnected and con-
nected to earth. The valve body is connected to earth with the
fastening screw (ref. F).
The valves may be mounted in any position.
Threaded port versions 1/4 (fi g 3a), 1/2 (fi g 3b):
Mount the valve with two screws (ref. 1) (not supplied).
Versions with NAMUR interface (fi g. 13a, 13b):
Before mounting the spool valve on the actuator, it must be
set to the required function:
- Select the interface plate with corresponds to the required
function: 3/2 NC or 5/2 (ref. 1a or 1b).
- Make sure the seal is properly seated (ref. 7).
- Mount the interface plate under the spool valve with the 2
supplied screws (ref. 8) and observe the mounting direction.
Make sure the indication of the function is placed on the
return side (polarising slot).
- Fit the two O-rings (ref. 9).
- Place the polarising pin on the actuator if necessary:
The polarising slot Ø 5 on the 3/2 interface plate is at A1.
The polarising slot Ø 5 on the 5/2 interface plate is at A2.
3834901-A (A = R1)
Availability, design and specifi cations are subject to change without notice. All rights reserved.
Installation and Maintenance Instructions
3/2 NC
GB
Series 551 solenoid valves, brass body, or series 551-553, stainless
steel body, 1/4“, 1/2" thread or NAMUR interface
5/2 - 5/3
PNEUMATIC CONNECTION (fi g. 3a, 3b, 13a and 13b)
Depending on the version (3/2 NC or 5/2), one or both stain-
less steel exhaust protectors can be used (see fi g. 2).
Connection of pneumatic pilot version:
G 1/8 or NPT 1/8 or G 1/4 or NPT 1/4.
Connection of pilot exhausts
The exhausts can be collected according to the version used.
Manual override
Depending on the version, the products are supplied with or
without manual override for operation without power. The
manual override is indicated with the symbol ( ) on fi g. 4, 5,
14, 15, 21 to 24, and ref. 10 on fi g. 3a, 3b, 13a, 13b.
The impulse-type or maintained (push/turn type) manual
override indicated by the symbol ( ) on fi g. 3a, 3b, 13a and
13b allows operation without power.
!
Prior to any putting into operation, make sure the
manual override is returned to its disengage position
“0” to prevent the risk of personal injury or damage to
equipment.
Adaption to external pilot supply
(fi g.3a, 3b, 13a et 13b,
ref. 6)
General recommendations for pneumatic connection
Correctly support and align the pipes to prevent mechanical
strain on the valve. When tightening, do not use the valve
as a lever; locate wrenches as close as possible to con-
nection point. To avoid damage to the equipment, DO NOT
OVERTIGHTEN pipe connections.
Threaded 1/4 (fi g 3a), 1/2 (fi g 3b) port versions:
Connection of the spool valve:
Connect pipes as indicated on the label:
- 3/2 NC function:
Pressure inlet at port 1 (1/4” or 1/2” thread). Pressure outlet
at port 2. Exhaust at port 3 (1/4” or 1/2” thread).
- 5/2 function:
Pressure inlet at port 1. Pressure outlet at ports 2 and 4.
The exhausts are channelled through the valve to ports 3 and
5.
Versions with NAMUR interface (fi g. 13a, 13b):
Connection of the spool valve:
Connect pipes as indicated on the label:
- 3/2 NC function:
Pressure inlet at port 1 (1/4” or 1/2” thread). Pressure outlet
at port 2. Exhaust at port 3. (brass body: 1/8 ; stainless steel
body: 1/4" or 1/2" thread).
Exhaust from the return spring chambers of the single act-
ing actuator is channelled through the spool valve to port
3. It is recommended to protect port 5 (if not used). Do not
seal it.
- 5/2 function:
Pressure inlet at port 1 (1/4” or 1/2” thread).
Pressure outlet at ports 2 and 4.
The exhausts are channelled through the valve to ports 3
and 5
(brass body: 1/8 ; stainless steel body: 1/4" or 1/2"
thread).
Connection of exhaust reducers (brass body)
Series 551 spool valves are supplied as ordered with or
without miniature 1/8” exhaust reducers, suffi x M (fi g. 13a).
These adjustable mini exhaust reducers are used to adjust
the actuator’s operating speed. They can also be connected
(1/8 thread) to collect the exhausts.
Assembly / Adjustment (fi g. 3a):
Version 3/2 NC = 1 exhaust reducer to be fi tted to port 3
Version 5/2 = 2 exhaust reducers to be fi tted to ports 3 and 5
Engage the screw (4) on the reducer into the hole and screw
it in until it stops; next turn it out to increase the exhaust fl ow
(never more than two turns, max. ow obtained at one
turn).
Tighten the locknut (4a) with a 13 mm wrench.
Make rough adjustment before pressurisation and fi ne-tune
after pressurisation.
ELECTRICAL CONNECTION
Version with solenoid operators with ASCO interface:
See additional installation instructions supplied with every
solenoid operator.
IP65-rated solenoid operator (fi g. 3a, 3b and 13a, 13b): Mount
the coil on the tube (rotatable through 360°) and then the
removable ISO 4400/EN 175101-803A connector (cable dia
6-10 mm) rotatable by 90° (3 pins: 2 + earth).
Version with CNOMO pad mounting: See additional
installation instructions supplied with every pilot valve.
General recommendations:
Electrical connections must be made by qualifi ed personnel
and according to applicable local standards and regulations.
Please note:
- Before starting any work, turn off the electrical current to
power off the components.
- Depending on the voltage, electrical components must be
grounded according to local standards and regulations.
Most valves are equipped with coils designed for continuous
duty. To prevent the risk of personal injury, do not touch the
solenoid operator which can become hot under normal oper-
ating conditions. If the valve is easily accessible, the installer
must provide for protection against accidental contact of the
solenoid operator.
MAINTENANCE
!
Prior to any maintenance work or putting into operation,
power off, depressurise and vent the valve to prevent
the risk of personal injury or damage to equipment.
ATEX versions: Strictly follow all procedures recommended
by Directive 99/92/EC and associated standards.
Cleaning
Maintenance of the valves depends on the operating con-
ditions. They must be cleaned at regular intervals. During
servicing, the components must be checked for excessive
wear. The components must be cleaned when a slowing
down of the cycle is noticed even though the pilot pressure
is correct or if any unusual noise or a leak is detected.
Sound emission
The exact determination of the sound level can only be car-
ried out by the user having the valve installed in his system.
The emission of sound depends on the application, fl uid and
type of equipment used.
Preventive maintenance
- Operate the valve at least once a month to check its func-
tion.
- If problems arise during maintenance or in case of doubt,
please contact us or one of our authorised representatives.
Troubleshooting
- Incorrect outlet pressure: Check the pressure on the supply
side of the valve; it must correspond to the values indicated
on the nameplate.
Caution: observe the minimum pilot pressure value 2 bar.
To avoid personal injury or damage to equipment, check that
the valve operates correctly before putting it back into operation.
Spare parts
Coils are available as spare parts.
If necessary, replace the entire valve.
5
4
3834901
3834901
DESCRIPTION DE LA CERTIFICATION
Versions concernées par cette mise en service (fi g 1 et 11) :
Corps laiton (Série 551) ou acier inox (Séries 551, 553),
monostable (rappel ressort) ou bistable, version 3/2 NF
(normalement fermée) ou 5/2, versions étanches par rap-
port à l'atmosphère. Versions sans ou avec commande
manuelle :
- à raccordement taraudé 1/4 (551) ou 1/2 (553)
- 551,
profondeur maxi des orifi ces de raccordement 11,5 mm
(Ne pas raccorder l’alimentation de pression à l’orifi ce
3 d’échappement. La construction “étanche à l’atmos-
phère” n’est pas adaptée pour la fonction “distributrice”
et une utilisation en fonction NO. Fonctions disponibles
en version spécifi que, nous consulter).
- à plan de pose suivant recommandation type NAMUR
pour adaptation directe sur actionneur pneumatique simple
effet (fonction 3/2 NF) ou double effet (fonction 5/2). Un
même distributeur s'adapte aux deux types de commande
par mise en place à la partie inférieure de l'une des deux
plaques interface 3/2 NF ou 5/2 fournies (fi g. 13a, 13b, rep.
1a et 1b). 551, 1/4, profondeur maxi des orifi ces de rac-
cordement 1/4 = 11,5 mm (
Ne pas raccorder l’alimentation
de pression à l’orifi ce 3 d’échappement. La construction
“étanche à l’atmosphère” n’est pas adaptée pour la fonc-
tion NO.
Fonctions disponibles en version spécifi que,
nous consulter).
- Raccorder les tuyauteries suivant les fonctions souhaitées en
tenant compte des repères d'orifi ces marqués sur le produit
et dans cette documentation.
- Veiller à ce qu’aucun corps étranger ne pénètre dans le circuit
afi n d'éviter tout blocage de la vanne. Limiter l'utilisation de
ruban ou pate d'étanchéité.
- Ces distributeurs et électrodistributeurs doivent être
utilisés que sur air, propre et sec, ou un gaz neutre.
Filtration minimale recommandée 50 microns. Le
point de rosé du fl uide utilisé doit être au minimum de
-10°C (18°F) en dessous de la température minimale à
laquelle le fl uide peut être soumis. En cas d'utilisation d'air
lubrifi é, le lubrifi ant doit être compatible avec les élastomères
utilisés. La qualité "air instrument" défi nie par la norme ANSI/
ISA S7.3 (1975) est supérieure aux exigences requises et
constitue de fait, un "media" acceptable pour ces vannes.
!
Protéger les orifi ces d'échappement des distribu-
teurs et des pilotes au moyen des protecteurs d'échap-
pement en acier inox. Pour le distributeur, raccorder ces
protecteurs au port 3 (3/2 NF) ou aux ports 3 - 5 (5/2). En
ambiance extérieure, stockage prolongé, et/ou en pré-
sence de poussières, liquides et agents présents dans
l'environnement, la présence de protecteurs d'échappe-
ment est impérative. La fi abilité de la vanne ne sera pas
garantie en cas d'utilisation d'un moyen de protection
des échappements différent que ceux préconisés.
- Plage de température autorisée :
-40°C à +80°C série 551 ; -40°C à +60°C série 553
- Plage de pression maximale de fonctionnement :
- 2 à 10 bar
- 2 à 8 bar
(ISSC/PISC/PISCIS/CFSCIS/CFSDIS/CFVTIS)
DESCRIPTION GENERALE
Versions ATEX 94/9/CE : Voir "conditions spéciales pour
une utilisation sûre".
Versions étanches par rapport à l'atmosphère : Les com-
posants internes du distributeur sont isolés de l'atmosphère
extérieure, le protégeant ainsi de tout environnement agressif.
Tous les orifi ces d'échappements étant canalisables, ils assu-
rent une meilleure protection de l'environnement, particulière-
ment recommandée pour les installations en zones sensibles
telles que salles blanches, industries pharmaceutiques ou
agro-alimentaires. Il est nécessaire de canaliser ou d'équiper
les échappements pour protéger les composants internes
du distributeur dans le cas d'utilisation à l'extérieur ou en
environnement diffi cile (poussières, liquides ou autres agents).
CONDITIONS SPECIALES POUR UNE UTILISATION SURE
ATEX 94/9/CE :
Le distributeur doit être relié à la terre (VoirMontage).
La température maximale du fl uide ne doit pas excéder la
température ambiante.
En cas de stockage prolongé avant mise en service, le
distributeur doit rester dans son emballage d'origine. Les
éléments de protection des orifi ces de raccordement et des
têtes magnétiques doivent rester en place.
Conditions de stockage : à l'abri des intempéries; tempéra-
ture : - 40°C à +70°C; humidité relative : 95 %
Après stockage à basse température, les distributeurs doivent
être remis progressivement à la température ambiante de
fonctionnement avant la première mise sous pression.
Les distributeurs sont conçus pour les domaines de fonctionne-
ment indiqués sur la plaque signalétique. Aucune modifi cation
ne peut être réalisée sur le matériel sans l’accord préalable
du fabricant ou de son représentant. Ces distributeurs sont
prévus pour fonctionner sur air ou gaz neutres fi ltrés. Ne
pas dépasser la pression maximale admissible = 10 bar (ou
8 bar avec pilote piézotronic/302/195 ATEX Ex ia). Respecter
la valeur minimale de pression de pilotage de 2 bar. La mise
en service et l'entretien de ces produits doivent être réalisés
par un personnel compétent.
Versions à commande pneumatique standard IP65 ou
prévues pour atmosphères explosibles sous forme de gaz,
vapeurs, brouillards et poussières selon la directive ATEX
94/9/CE.
(Le classement en zone de cette version est
défi nie par l'étiquette ATEX, rep.E1).
Mode de protection, série 551 : II 1 GD c T6 T85°C Ta -40°C à +65°C
Mode de protection, série 553 : II 2 GD c T6 (T85°C) - T5 (T100°C)
Attestation d'examen CE de type (séries 551) : INERIS 03 ATEX 0219 X
Le respect des exigences essentielles en ce qui concerne la
sécurité et la santé est assuré par la conformité aux normes
européennes EN 13463-1 et EN 13463-5.
Versions à commande électropneumatique équipées de
têtes magnétiques :
- étanches IP65 ou certifi ées pour atmosphères explosibles
selon la Directive ATEX 94/9/CE
- Versions têtes magnétiques selon plan de pose ASCO,
standard IP65 ou pour atmosphères explosibles, II 3D IP65/
IP67 ou ATEX Ex d, m, em, Ex ia (série 551 : II 1G/2D
Ex ia IIC IP65/IP67 ou série 553 : II 2G/D Ex ia IIC IP65/
IP67).
-
Versions à pilotes, selon plan de pose CNOMO E06.05.80
(taille 30) ou CNOMO E06.36.120N (taille 15), standard
IP 65 ou montage de pilotes pour atmosphères explosibles
ATEX, Ex d ou Ex ia.
Attention (pilotes CNOMO) :
Le placement en zones (ATEX
1999/92/CE), est défi ni prioritairement par le marquage
indiqué sur l'étiquette fi g.10 et 20 (rep. E1 ou E2) placée
sur le corps du distributeur. Mode de protection, selon
ATEX 94/9/CE : II 1GD c T6 T85°C Ta -40°C à +65°C.
Attestation d'examen CE de type : INERIS 03 ATEX 0219 X
Prendre en compte la catégorie, les pressions de fonc-
tionnement et la température la moins favorable lors d'un
assemblage avec un pilote ATEX 94/9/CE. Le respect des
exigences essentielles en ce qui concerne la sécurité et la
santé est assuré par la conformité aux normes européennes
EN 13463-1 et EN 13463-5. Respecter le sens de montage
des pilotes indiqué par les fi gures 4/5/14/15/21/22/23/24 et
les couples de serrage indiqués.
Pour les têtes magnétiques et pilotes ATEX 94/9/CE, suivre
impérativement les prescriptions d'utilisation décrites
dans chaque notice de mise en service spécifi que fournie
avec le produit.
MONTAGE
!
Versions ATEX 94/9/CE : S'assurer que toutes les parties
métalliques ou conductrices soient toujours interconnectées et
reliées à la terre. La liaison à la terre du corps de distributeur
se fait par montage de la vis de fi xation (rep. F).
Les distributeurs peuvent être montés dans n'importe quelle
position.
Versions taraudés 1/4 (fi g. 3a) 1/2 (fi g. 3b) :
Monter le distributeur à l'aide de deux vis (rep.1), non fournies.
Versions à plan de pose NAMUR (fi g. 13a, 13b) :
Avant montage du distributeur sur l'actionneur, adapter l'ap-
pareil à la fonction souhaitée :
- Sélectionner la plaque interface correspondant à la fonction
nécessaire 3/2 NF ou 5/2 (rep.1a ou 1b).
Instructions de mise en service et d'entretien
3/2 NF
FR
Distributeurs Série 551, corps laiton ou Séries 551-553, corps acier inox
taraudé 1/4, 1/2 ou à plan de pose NAMUR
5/2 - 5/3
- S'assurer de la présence et de la mise en place correcte
du joint de forme (rep.7).
- Assembler la plaque sous le distributeur à l'aide des 2 vis
(rep.8) fournies, en respectant le sens de montage : le repère
de fonction doit être placé coté rappel (détrompeur).
- Monter les deux joints toriques (rep.9).
- Placer, si nécessaire, le pion de détrompage sur l'actionneur:
Sur la plaque 3/2, le trou de détrompage Ø 5 se situe en A1.
Sur la plaque 5/2, le trou de détrompage Ø 5 se situe en A2.
RACCORDEMENT PNEUMATIQUE (fi g. 3a, 3b,13a et 13b)
Selon la version 3/2 NF ou 5/2, un ou deux protecteurs
d'échappement en acier inox peuvent être adapté(s), voir
g. 2.
Raccordement du pilotage version pneumatique :
G 1/8 ou NPT 1/8 ou G 1/4 ou NPT 1/4.
Raccordement des échappements de pilotage
Possibilité de collecter les échappements selon les versions.
Commande manuelle
Selon les versions les produits sont fournis sans ou avec une
commande manuelle, pour fonctionnement hors tension..
Elle est signalée par le symbole ( ), sur les fi g. 4, 5, 14, 15,
21 à 24, et par le rep. 10, sur les fi g. 3a, 3b, 13a, 13b.
La commande manuelle à impulsion ou à position main-
tenue (type pousser/tourner) , signalée par le symbole (
) sur les fi g. 3a, 3b, 13a et 13b, permet le fonctionnement
hors tension.
!
Avant toute opération de remise en marche, valider
le retour en position "0" (non-enclenchée) de la com-
mande manuelle, pour prévenir tout risque d'accident
corporel ou matériel.
Adaptation en alimentation externe du pilotage
(fi g.3a, 3b, 13a et 13b, rep.6)
Recommandations générales pour raccordement pneu-
matique
Soutenir et aligner correctement les tuyauteries pour éviter
toute contrainte mécanique sur le distributeur. Au serrage,
ne pas se servir de l'appareil comme d'un levier; Position-
ner les clés de serrage aussi près que possible du point
de raccordement. Afi n d’éviter toute détérioration, NE PAS
TROP SERRER les raccords des tuyauteries.
Versions taraudés 1/4 (fi g. 3a), 1/2 (fi g. 3b) :
Raccordement du distributeur :
Raccorder les tuyauteries en fonction des repères indiqués
sur l'étiquette.
- Fonction 3/2 NF :
Arrivée de pression par l'orifi ce 1 (1/4 ou 1/2). Utilisation
par l'orifi ce 2. Echappement par l'orifi ce 3 (1/4 ou 1/2)
- Fonction 5/2 :
Arrivée de pression par l'orifi ce1. Utilisation par les orifi ces
2 et 4.
Les échappements sont canalisés vers les orifi ces 3 et 5.
Versions à plan de pose NAMUR (fi g 13a, 13b) :
Raccordement du distributeur :
Raccorder les tuyauteries en fonction des repères indiqués sur
l'étiquette.
- Fonction 3/2 NF :
Arrivée de pression par l'orifi ce 1 (1/4 ou 1/2). Utilisation
par l'orifi ce 2. Echappement par l'orifi ce 3 (corps laiton :
1/8 ; corps acier inox : 1/4 ou 1/2).
L'échappement des chambres des ressorts de rappel de
l'actionneur simple effet est canalisé au travers du distri-
buteur vers l'orifi ce 3 raccordable. Il est recommandé de
protéger l'orifi ce 5 (non utilisé) tout en évitant de l'obturer.
- Fonction 5/2 :
Arrivée de pression par l'orifi ce 1 (1/4 ou 1/2).
Utilisation par les orifi ces 2 et 4.
Les échappements de l'actionneur sont canalisés au
travers du distributeur vers les orifi ces 3 et 5 (corps
laiton : 1/8 ; corps acier inox : 1/4 ou 1/2).
-
Raccordement des réducteurs d'échappement (corps laiton)
Suivant la demande, les distributeurs série 551 sont fournis
sans ou avec réducteurs d'échappement miniatures 1/8, suffi xe
M (fi g. 13a).
Ces mini-réducteurs d'échappement réglables permettent
d'adapter la vitesse de manoeuvre de l'actionneur. Ils sont
également raccordables (fi letage 1/8) pour collecter les
échappements.
Montage / Réglage (fi g. 13a) :
Version 3/2 NF = 1 réducteur à adapter sur l'orifi ce 3
Version 5/2 = 2 réducteurs à adapter sur les orifi ces 3 et 5
Serrer dans l'orifi ce la vis (4) du réducteur jusqu'en butée,
puis dévisser pour augmenter le débit d'échappement sans
jamais dépasser 2 tours (débit maxi obtenu à partir d'1
tour).
Bloquer le contre-écrou (4a) avec une clé plate de 13 mm.
Le réglage doit s'effectuer hors pression, il est à affi ner lors
des essais sous pression.
RACCORDEMENT ELECTRIQUE
Version à têtes magnétiques interface ASCO : Se réfé-
rer à la notice d'installation complémentaire fournie avec
chaque tête magnétique.
Tête magnétique étanche IP65 (fi g. 3a, 3b et 13a, 13b) :
Adapter la bobine sur le tube (orientable sur 360°) puis
le connecteur débrochable ISO 4400/EN 175101-803A
(câble Ø6-10 mm), orientable par 90° x 90° (3 broches : 2
+ masse).
Version à plan de pose CNOMO : Se référer à la notice
d'installation complémentaire fournie avec chaque pilote.
Recommandations générales
Le raccordement électrique doit être réalisé par un personnel
qualifi é et selon les normes et règlements en vigueur.
Attention :
- Avant toute intervention, couper l'alimentation électrique
pour mettre hors tension les composants.
- Selon la tension, les composants électriques doivent être
mis à la terre conformément aux normes et règlements locaux.
La plupart des électrodistributeurs comportent des bobi-
nages prévus pour mise sous tension permanente. Pour
éviter toute brûlure, ne pas toucher la tête magnétique qui,
en fonctionnement normal et en permanence sous tension,
peut atteindre une température élevée. Si l'électrodistribu-
teur est facilement accessible, l'installateur doit prévoir une
protection de la tête magnétique.
ENTRETIEN
!
Avant toute opération d'entretien ou de remise en
marche, couper l'alimentation du distributeur, dépres-
suriser et purger,
pour prévenir tout risque d'accident
corporel ou matériel.
Versions ATEX : Suivre impérativement lors de la phase
de maintenance les recommandations de la directive
99/92/CE et normes associées.
Nettoyage
L’entretien des distributeurs varie suivant leurs conditions
d’utilisation. Si nécessaire procéder à un nettoyage pério-
dique. Lors de l’intervention, les composants doivent être
examinés pour détecter toute usure excessive. Un net-
toyage est nécessaire lorsqu'on observe un ralentissement
de la cadence alors que la pression de pilotage est cor-
recte ou lorsqu'un bruit anormal ou une fuite est constaté.
Bruit de fonctionnement
L’utilisateur ne pourra déterminer avec précision le niveau so-
nore émis qu'après avoir monté le composant sur l'installation.
Le bruit de fonctionnement varie selon l’utilisation, le fl uide et le
type de matériel.
Entretien préventif
- Faire fonctionner le distributeur au moins une fois par mois
pour vérifi er son ouverture et sa fermeture.
- En cas de problème lors du montage/entretien ou en cas
de doute, nous contacter ou nos représentants offi ciels.
Conseils en dépannage
- Pression de sortie incorrecte : Vérifi er la pression à l'en-
trée du distributeur, elle doit correspondre aux valeurs
admises sur l'étiquette d'identifi cation.
Attention, respecter les valeurs minimales de pression de
pilotage : 2 bar
Pour prévenir tout risque d'accident corporel ou matériel,
vérifi er que le distributeur fonctionne correctement avant
de le remettre en service.
Rechange
La bobine est proposée en pièce de rechange.
Si nécessaire, changer le distributeur complet.
Instructions de mise en service et d'entretien
3/2 NF
FR
Distributeurs Série 551, corps laiton ou Séries 551-553, corps acier inox
taraudé 1/4, 1/2 ou à plan de pose NAMUR
5/2 - 5/3
7
6
3834901
3834901
BESCHREIBUNG DER ZERTIFIZIERUNG
Von der Zertifi zierung betroffene Ausführungen (Abb. 1 und 11):
Baureihe 551, Gehäuse aus Messing, Baureihe 551-553, Ge-
häuse aus Edelstahl, monostabil (Federrückstellung) oder
bistabil, 3/2-Version NC (normal geschlossen) oder 5/2, gegen
Atmosphäre abgedichtete Versionen. Versionen mit oder ohne
Handhilfsbetätigung:
- mit 1/4“- (551) oder 1/2"- (553) Gewindeanschluss,
- 551,
max.
Tiefe der Anschlüsse 11,5 mm. (Der Druckanschluss ist nicht
am Entlüftungsanschluss 3 anzuschließen. Die “hermetisch
abgedichtete” Ausführung ist nicht für eine "verteilende"
Funktion oder Verwendung in NO-Funktion ausgelegt. Funk-
tionen in Sonderausführungen auf Anfrage.).
- mit Auffl anschbild gemäß NAMUR für die direkte Montage auf
einfachwirkende (Funktion 3/2 NC) oder doppeltwirkende (Funk-
tion 5/2) Pneumatik-Antriebe. Das Ventil lässt sich wahlweise auf
die Funktion NC 3/2 oder 5/2 umstellen durch Montage einer der
entsprechenden im Lieferumfang enthaltenen Adapterplatten auf
der Unterseite des Ventils (Abb. 13a, 13b, Nr. 1a und 1b).
551,
m
ax. Tiefe der 1/4"-Anschlüsse = 11,5 mm. (Der Druckan-
schluss ist nicht am Entlüftungsanschluss 3 anzuschließen.
Die “hermetisch abgedichtete” Ausführung ist nicht für die
NO-Funktion ausgelegt. Funktionen in Sonderausführungen
auf Anfrage.).
- Die Verrohrung ist entsprechend der gewünschten Funktion und
der Kennzeichnung der Anschlüsse auf dem Produkt und gemäß
dieser Anleitung vorzunehmen.
- Es ist darauf zu achten, dass keine Fremdkörper in das Ventil
gelangen, um ein Blockieren der Ventilfunktion zu vermeiden.
Verwenden Sie Dichtungsband oder –mittel nur spärlich.
- Die Ventile sind nur mit sauberer und trockener Luft oder mit
neutralem Gas zu betreiben. Empfohlene Mindest-Filterfeinheit :
50 Mikron. Der Taupunkt des verwendeten Mediums muss min-
destens -10°C (18°F) unterhalb der für das Medium zulässigen
Mindesttemperatur liegen. Bei der Verwendung geölter Luft ist die
Beständigkeit der verwendeten Dichtungsmaterialien zu überprüfen.
Die durch die ANSI/ISA-Norm S7.3 (1975) festgelegte Qualität von
Instrumentenluft übersteigt die erfordDie Entlüftungsanschlüsse
der Ventile sind mit den Schalldämpfern aus Edelstahl zu versehen
(siehe Abb. Anforderungen und ist somit für diese Ventile zulässig.
!
Die Entlüftungsanschlüsse der Ventile sind mit den
Schalldämpfern aus Edelstahl zu versehen. Die Schall-
dämpfer sind am Anschluss 3 (3/2 NC) oder an den Anschlüs-
sen 3 - 5 (5/2) der Ventile anzuschließen. Bei einem Einsatz
im Freien, bei einer längeren Lagerung und/oder bei einem
Einsatz unter schwierigen Bedingungen (Staub, aggressive
Medien oder andere Schmutzpartikel) ist die Verwendung von
Schalldämpfern zwingend erforderlich. Bei Verwendung einer
anderen Art von Schutz als die mitgelieferten Schalldämpfern
ist die Zuverlässigkeit der Ventile nicht mehr gewährleistet.
- Zulässige Temperatur: -40 °C bis +80 °C (Baureihe 551); -40°C
bis +60°C (Baureihe 553).
- Max. Betriebsdruck:
- 2 bis 10 bar
- 2 bis 8 bar (ISSC/PISC/PISCIS/CFSCIS/CFSDIS/CFVTIS)
ALLGEMEINE BESCHREIBUNG
Ausführungen nach ATEX 94/9/EG: Siehe „Besondere Bedin-
gungen für den sicheren Einsatz“:
Hermetisch gegen Atmosphäre abgedichtete Ausführungen:
Die Innenteile des Wegeschiebers sind hermetisch gegen Atmo-
sphäre abgedichtet und somit vor dem Eindringen von aggressiven
Medien geschützt. Die Entlüftungsanschlüsse können zum Schutz
der Umgebung gefasst und abgeführt werden; dies wird insbeson-
dere für Anlagen in empfi ndlichen Bereichen (z.B. in Labors oder
der Pharma- und Nahrungsmittelindustrie) empfohlen. Bei einem
Einsatz im Freien oder unter schwierigen Bedingungen (Staub, ag-
gressive Medien oder andere Schmutzpartikel) ist es notwendig, die
Entlüftungsanschlüsse entweder zu fassen und abzuführen oder mit
einem Schutz (z.B. Schalldämpfer) zu versehen, um die Innenteile
des Wegeschiebers zu schützen.
BESONDERE BEDINGUNGEN FÜR DEN SICHEREN EINSATZ
Ausführungen nach ATEX 94/9/EG: Das Ventil ist zu erden (siehe
"Einbau").
Die maximale Mediumstemperatur darf die Umgebungstemperatur
nicht übersteigen.
Wenn der Zylinder vor Inbetriebnahme länger gelagert wird, sollte
er in der Originalverpackung aufbewahrt werden. Die Schutzab-
deckungen an den Anschlussöffnungen und Magnetköpfen sollen
nicht entfernt werden.
Lagerbedingungen: geschützt lagern ;
Temperatur : -40°C bis 70 °C ; relative Feuchtigkeit: 95 %
Nach einer Lagerung bei niedriger Temperatur müssen die
Ventile vor der Druckbeaufschlagung nach und nach an die
Betriebstemperatur angepasst werden.
Die Ventile sind für den Betrieb innerhalb der auf den Typenschildern
angegebenen Daten ausgelegt. Änderungen an den Produkten
dürfen nur nach vorheriger Zustimmung des Herstellers oder einem
seiner ordnungsgemäß ermächtigten Vertreter vorgenommen wer-
den. Die Ventile sind für den Betrieb mit neutralem Gas oder Luft,
gefi ltert, ausgelegt. Der max. zulässige Ventildruck von 10 bar (oder
8 bar bei einem Piezotronic-Pilotventil nach ATEX Ex ia) darf nicht
überschritten werden. Beachten Sie den Mindeststeuerdruck von 2
bar. Der Einbau und die Wartung des Ventils ist von Fachpersonal
auszuführen.
Pneumatisch betätigte Ausführungen, IP65 als Standard, oder
Ausführungen in Übereinstimmung mit der ATEX-Richtlinie
94/9/EG für den Einsatz in durch Gase, Dämpfe, Nebel und/
oder Stäube verursachten explosionsfähigen Atmosphären. (Die
Zoneneinteilung für diese Version wird auf dem ATEX-Etikett, Nr.
E1, angegeben.)
Schutzart, Baureihe 551: II 1 GD c T6 T85°C Ta -40°C bis +65°C.
Schutzart, Baureihe 553: II 2 GD c T6 (T85°C) - T5 (T100°C)
EG-Baumusterprüfbescheinigung-Nr. (Baureihe 551) INERIS
03 ATEX 0219 X
Die Einhaltung der grundlegenden Gesundheits- und Sicherheits-
anforderungen wird durch die Übereinstimmung mit den Europä-
ischen Normen EN 13463-1 und EN 13463-5 gewährleistet.
Elektropneumatisch angesteuerte Ausführungen mit Magnet-
köpfen:
- Dichte Ausführung nach IP65 oder nach der ATEX-Richtlinie 94/9/
EG für explosionsfähige Atmosphären zugelassene Ausführung.
Ausführungen mit Magnetköpfen mit ASCO-Anschlussbild,
IP65 als Standard, oder für den Einsatz in explosionsfähigen
Atmosphären gemäß II 3D IP65/IP67 oder gemäß ATEX Ex d, m,
em, Ex ia zugelassen (Baureihe 551: II 1G/2D Ex ia IIC IP65/
IP67 oder Baureihe 553: II 2G/D Ex ia IIC IP65/IP67).).
Ausführungen mit Pilotventilen mit Auffl anschbild gemäß
CNOMO E06.05.80 (Größe 30) oder CNOMO E06.36.120N
(Größe 15), IP65 als Standard, oder Montage von Pilotventilen
für den Einsatz in explosionsfähigen Atmosphären gemäß ATEX
Ex d oder Ex ia zugelassen.
Wichtiger Hinweis (CNOMO-Pilotventile): Der Einsatz in den
Zonen (ATEX 1999/92/EG) richtet sich in erster Linie nach den
Angaben auf dem Etikett (Abb. 10 und 20, Nr. E1 oder E2) am
Gehäuse des Wegeventils. Schutzart nach ATEX 94/9/EG: II 1
GD c T6 T85°C Ta -40°C bis +65°C.
EG-Baumusterprüfbescheinigung-Nr: INERIS 03 ATEX 0219 X
Beim Zusammenbau mit einem Pilotventil nach ATEX 94/9/
EG ist die ungünstigste Kategorie, max. Betriebsdruck und
Temperatur anzunehmen. Die Einhaltung der grundlegenden
Gesundheits- und Sicherheitsanforderungen wird durch die Über-
einstimmung mit den Europäischen Normen EN 13463-1 und EN
13463-5 gewährleistet.
Die in den Abb. 4/5/14/15/21/22/23/24 angegebene Montagepo-
sition für die Pilotventile sowie die Anziehdrehmomente sind zu
beachten.
Für die Magnetköpfe und Pilotventile nach ATEX 94/9/EG sind
die in den jeweiligen, dem Produkt beigelegten Einbau- und
Wartungsanweisungen beschriebenen Einsatzvorschriften
zwingend zu befolgen.
EINBAU
!
Ausführungen nach ATEX 94/9/EG: Alle Metallteile bzw.
leitenden Teile sind miteinander zu verbinden und zu erden. Das
Ventilgehäuse wird durch die Befestigungsschraube (Nr. F) geerdet.
Die Wegeschieber können ohne Beeinträchtigung der Funktion in
jeder beliebigen Einbaulage montiert werden.
Ausführung mit 1/4"-Gewinde (Abb. 3a) oder 1/2"-Gewinde
(Abb. 3b):
Montieren Sie den Wegeschieber mit zwei Schrauben (Nr. 1); diese
sind nicht im Lieferumfang enthalten.
Ausführung mit Auffl anschbild gemäß NAMUR (Abb. 13a, 13b):
Vor der Montage des Wegeschiebers auf dem Antrieb ist das Gerät
auf die gewünschte Funktion einzustellen:
- Wählen Sie die für die Funktion 3/2 NC oder 5/2 bestimmte Ad-
INSTALLATIONS- UND WARTUNGSANWEISUNGEN
3/2 NC
DE
Magnetventil-Baureihe 551, Messinggehäuse oder Magnetventil-Baureihe 551/553,
Edelstahlgehäuse, 1/4" oder 1/2"-Gewinde oder NAMUR-Auffl anschbild
5/2 - 5/3
apterplatte aus (Nr. 1a oder 1b).
- Stellen Sie sicher, dass die Funktionsdichtung vorhanden und
korrekt eingelegt ist (Nr. 7).
- Befestigen Sie die Platte unter dem Ventil anhand der beiden
mitgelieferten Schrauben (Nr. 8). Beachten Sie dabei die Montage-
richtung: Die Nummer für die Funktion muss auf der Rückstellseite
(Montagesicherung) platziert sein.
- Montieren Sie die beiden O-Ringe (Nr. 9).
- Platzieren Sie, falls erforderlich, die Montagesicherung auf den
Antrieb:
Bei der 3/2-Platte befi ndet sich die Montagesicherung Ø bei A1.
Bei der 5/2-Platte befi ndet sich die Montagesicherung Ø bei A2.
PNEUMATISCHER ANSCHLUSS (Abb. 3, 13a und 13b)
Je nach Version 3/2 NC oder 5/2 können ein bzw. zwei Schalldämpfer
aus Edelstahl montiert werden (siehe Abb. 2).
Anschluss der pneumatisch betätigten Ansteuerung:
G 1/8 oder NPT 1/8 bzw. G 1/4 oder NPT 1/4.
Anschluss der Vorsteuerentlüftungen
Die Entlüftungen können gefasst werden.
Handhilfsbetätigung
Je nach Ausführung werden die Produkte für den spannungs-
losen Betrieb mit oder ohne Handhilfsbetätigung geliefert. Die
Handhilfsbetätigung ist auf den Abb. 4, 5, 14, 15, 21 bis 24 mit
dem Symbol (
) gekennzeichnet und mit der Nr. 10 auf den Abb.
3a, 3b, 13a, 13b.
Die auf den Abb. 3a, 3b, 13a und 13b mit dem Symbol ( )
gekennzeichnete impulsbetätigte oder rastende (Drück-Dreh)
Handhilfsbetätigung ermöglicht den spannungslosen Betrieb.
!
Um Personen- und Sachschäden zu vermeiden, muss vor
der Inbetriebnahme die Handhilfsbetätigung in die Stellung "0"
(entrastet) gesetzt werden.
Anpassung auf externe Vorsteuerung
(Abb. 3a, 3b, 13a und 13b, Nr. 6)
Allgemeine Empfehlungen für den pneumatischen Anschluss
Die Rohrleitungen sind ordnungsgemäß abzustützen und anzu-
ordnen, um eine mechanische Fehlbeanspruchung des Wege-
schiebers zu vermeiden. Das Ventil darf nicht als Gegenhalter
benutzt werden.Das Werkzeug ist so nahe wie möglich am
Anschlusspunkt anzusetzen. Um Schäden zu vermeiden, dürfen
die Rohrverbindungen nicht zu stark angezogen werden.
Ausführungen mit 1/4"- (Abb. 3a) oder 1/2"-Gewindeanschluss
(Abb. 3b):
Anschluss des Wegeschiebers :
Die Verrohrung ist entsprechend den Hinweisen auf dem Etikett
anzuschließen.
- Funktion 3/2 NC:
Druckbeaufschlagung über Anschluss 1 (1/4 oder 1/2). Verbrau-
cher über Anschluss 2. Entlüftung über Anschluss 3 (1/4 oder
1/2).
- Funktion 5/2:
Druckbeaufschlagung über Anschluss 1. Verbraucher über
Anschlüsse 2 und 4. Die Entlüftungen sind in den Anschlüssen
3 und 5 zusammengefasst.
Ausführungen mit Auffl anschbild gemäß NAMUR (Abb. 13a, 13b):
Anschluss des Wegeschiebers:
Die Verrohrung ist entsprechend den Hinweisen auf dem Etikett
anzuschließen.
- Funktion 3/2 NC:
Druckbeaufschlagung über Anschluss 1 (1/4 oder 1/2). Verbrau-
cher über Anschluss 2. Entlüftung über Anschluss 3 (Messing-
gehäuse: 1/8; Edelstahlgehäuse: 1/4 oder 1/2). Die Entlüftung
der Rückstellfederkammern des einfachwirkenden Antriebs ist
im anschließbaren Anschluss 3 des Wegeschieber zusammen-
gefasst. Es wird empfohlen, den (nicht verwendeten) Anschluss
5 mit einem Schutz zu versehen, ohne dabei den Anschluss
zu verschließen.
- Funktion 5/2:
Druckbeaufschlagung über Anschluss 1 (1/4 oder 1/2). Verbrau-
cher über Anschlüsse 2 und 4. Die Entlüftungen sind in den
Anschlüssen 3 und 5 (Messinggehäuse: 1/8; Edelstahlgehäuse:
1/4 oder 1/2) zusammengefasst.
Anschluss der Abluftdrosseln (Gehäuse aus Messing)
Die Wegeventile der Baureihe 551 sind je nach Auftrag mit oder
ohne Mini-1/8"-Abluftdrosseln ausgestattet, Zusatz M (Abb. 13a).
Mit diesen Mini-Abluftdrosseln lässt sich die Geschwindigkeit
des Antriebs regulieren. Sie können auch angeschlossen werden
(1/8"-Gewinde), um die Entlüftungen zusammenzufassen.
Montage / Einstellung (Abb. 13a):
3/2-Ausführung NC = 1 Abluftdrossel an Anschluss 3
5/2-Ausführung = 2 Abluftdrosseln an den Anschlüssen 3 und 5
Drehen Sie die Schraube (4) in den Anschluss der Drossel bis
zum Anschlag ein und drehen Sie sie anschließend wieder zurück,
um den Entlüftungsdurchfl uss zu erhöhen (jedoch nicht mehr
als 2 Umdrehungen - max. Durchfl uss bereits bei 1 Umdrehung).
Blockieren Sie die Mutter (4a) mit einem Gabelschlüssel SW 13.
Führen Sie die Grobeinstellung vor der Druckbeaufschlagung
und die Feineinstellung nach der Druckbeaufschlagung durch.
ELEKTRISCHER ANSCHLUSS
Ausführung mit Magnetköpfen mit ASCO-Anschlussbild:
Siehe die zusätzlichen, jedem Magnetkopf beigelegten Installa-
tionsanweisungen.
Magnetkopf IP65 (Abb. 3a, 3b und 13a, 13b): Zuerst den Magnet
auf das Rohr montieren (um 360° drehbar) und anschließend die
Leitungsdose nach ISO 4400/EN 17501-803A (Kabel-Ø6-10 mm),
um 90° umsetzbar (3 Pins: 2 + Erde).
Ausführung mit CNOMO-Anschlussbild Siehe die zusätzlichen,
jedem Pilotventil beigelegten Installationsanweisungen.
Allgemeine Empfehlungen
Der elektrische Anschluss ist von Fachpersonal entsprechend
den geltenden Normen und Richtlinien auszuführen.
ACHTUNG:
- Vor Beginn jeglicher Arbeiten ist sicherzustellen, dass die Kom-
ponenten spannungslos geschaltet sind.
- Je nach Spannungsbereich müssen elektrische Komponenten
einen Schutzleiteranschluss entsprechend den jeweils vor Ort
geltenden Normen und Vorschriften erhalten.
Die meisten Ventile sind mit Magneten für Dauerbetrieb ausge-
rüstet. Zur Vermeidung von Personen- und Sachschäden sollte
jede Berührung mit dem Magnet vermieden werden, da dieser
bei längerem Betrieb heiß werden kann. Bei leicht zugänglichem
Magnetventil sollte vom Installateur ein Schutz vorgesehen
werden, um jegliches versehentliches Berühren zu vermeiden.
WARTUNG
!
Um Personen- und Sachschäden zu vermeiden, muss vor
der Wartung oder Inbetriebnahme die Versorgung des Ventils
unterbrochen sowie das Ventil drucklos geschaltet und entlüftet
werden.
Ausführungen nach ATEX: Bei der Wartung sind die Bestim-
mungen der Richtlinie 99/92/EG und zugehörige Normen
zwingend einzuhalten.
Reinigung
Die Wartung der Ventile hängt von den jeweiligen Einsatzbe-
dingungen ab. Sie sollten in regelmäßigen Abständen gereinigt
werden. Während des Reinigungsvorgangs sollten alle Teile auf
Verschleiß untersucht werden. Eine Reinigung ist notwendig, wenn
sich die Schaltfrequenz bei korrektem Vorsteuerdruck verlangs-
amt oder wenn ungewöhnliche Geräusche oder Undichtigkeiten
festgestellt werden.
Geräuschemission
Diese hängt sehr stark vom Anwendungsfall, den Betriebsdaten
und dem Medium, mit denen das Produkt beaufschlagt wird, ab.
Eine Aussage über die Geräuschemission des Produktes muss
deshalb von demjenigen getroffen werden, der das Produkt
innerhalb einer Maschine in Betrieb nimmt.
Vorbeugende Wartung
- Setzen Sie das Ventil zur Überprüfung der Öffnungs- und
Schließfunktion mindestens einmal im Monat in Betrieb.
- Treten Schwierigkeiten beim Einbau oder bei der Wartung auf
sowie bei Unklarheiten ist mit uns oder unseren zugelassenen
Vertretern Rücksprache zu halten.
Fehlerbeseitigung
- Falscher Ausgangsdruck: Überprüfen Sie den Druck am Ein-
gang des Ventils; er muss mit den zulässigen Werten auf dem
Typenschild übereinstimmen.
Beachten Sie den Mindeststeuerdruck von 2 bar.
Um Personen- und Sachschäden zu vermeiden, prüfen Sie
vor der Wiederinbetriebnahme die richtige Funktionsweise des
Ventils.
Ersatzteile
Die Magnetspule ist als Ersatzteil erhältlich.
Tauschen Sie, falls erforderlich, das gesamte Ventil aus.
INSTALLATIONS- UND WARTUNGSANWEISUNGEN
3/2 NC
DE
Magnetventil-Baureihe 551, Messinggehäuse oder Magnetventil-Baureihe 551/553,
Edelstahlgehäuse, 1/4" oder 1/2"-Gewinde oder NAMUR-Auffl anschbild
5/2 - 5/3
9
8
3834901
3834901
DESCRIPCIÓN DE LA CERTIFICACIÓN
Versiones afectadas por esta puesta en marcha (fi g 1 y 11) :
Serie 551, cuerpo de latón, o Serie 551,553, cuerpo de
acero inox., monoestable (retorno resorte) o biestable,
versión 3/2 NC (normalmente cerrada) o 5/2, versiones
estancas con respecto a la atmósfera. Versiones sin o
con mando manual :
- con conexión roscada 1/4 (551) o 1/2 (553)
- 551, pro-
fundidad máxima de los orifi cios de racordaje 11,5 mm
(No conectar la alimentación de presión al orifi cio 3 de
escape. La construcción “estanca a la atmósfera” no
está adaptada para la función “distribuidora” o utiliza-
ción en función NA. Funciones disponibles en versión
específi ca, consultar).
- con plano de acoplamiento según recomendación
NAMUR para adaptación directa en actuador neumático de
simple efecto (función 3/2 NC) o doble efecto (función 5/2).
Un mismo distribuidor se adapta a los dos tipos de mando
mediante la colocación en la parte inferior de una de las dos
placas interface 3/2 NC o 5/2 provistas (fi g. 13a, 13b, ref. 1a
y 1b). 551, 1/4, profundidad máxima de los orifi cios de
racordaje 1/4 = 11,5 mm (
No conectar la alimentación de
presión al orifi cio 3 de escape. La construcción “estan-
ca a la atmósfera” no está adaptada para la función NA.
Funciones disponibles en versión específi ca, consultar).
- Conectar las tuberías según las funciones deseadas tenien-
do en cuenta las referencias de los orifi cios marcados en el
producto y en esta documentación.
- Verifi que que ningún cuerpo extraño penetre en el circuito
con el fi n de evitar todo bloqueo de la válvula. Limitar la uti-
lización de goma o pasta de estanquidad.
- Estos distribuidores y electrodistribuidores deben ser uti-
lizados solamente con aire, limpio y seco, o un gas neutro.
Filtración mínima recomendada 50 micras. El punto de rocío
del fl uido utilizado debe ser como mínimo
-10°C (18°F) por debajo de la temperatura mínima a la cual
el fl uido puede ser sometido. En caso de utilización de aire
lubricado, el lubricante debe ser compatible con los elastó-
meros utilizados. La calidad "aire instrumento" defi nida por
la norma ANSI/ISA S7.3 (1975) es superior a las exigencias
requeridas y constituye de hecho, un "medio" aceptable para
estas válvulas.
!
Proteger los orifi cios de escape de los distribuidores
y de los pilotos mediante protectores de escape de acero
inox. Para el distribuidor, conectar estos protectores al
orifi cio 3 (3/2 NC) o a los orifi cios 3 - 5 (5/2). En ambiente
exterior, almacenaje prolongado, y/o en presencia de
polvo, líquidos y agentes presentes en el ambiente, es
obligatoria la presencia de protectores de escape. La
abilidad de la válvula no estará garantizada en caso
de utilización de un medio de protección de los escapes
diferente a los recomendados.
- Rango de temperatura autorizado :
-40°C a +80°C (serie 551); -40°C a +60°C (serie 553).
- Rango de presión máxima de funcionamiento :
- 2 a 10 bar
- 2 a 8 bar
(ISSC/PISC/PISCIS/CFSCIS/CFSDIS/CFVTIS)
DESCRIPCIÓN GENERAL
Versiones ATEX 94/9/CE : Ver "condiciones especiales para
una utilización segura".
Versiones estancas con respecto a la atmósfera : Los
componentes internos del distribuidor están aislados de la
atmósfera exterior, protegiéndole así de todo entorno agre-
sivo. Todos los orifi cios de escape son canalizables, por lo
que aseguran mayor protección del entorno, particularmente
recomendada para las instalaciones en zonas sensibles como
salas blancas, industrias farmacéuticas o agro-alimentarias.
Es necesario canalizar o equipar los escapes para proteger
los componentes internos del distribuidor en el caso de uti-
lización en el exterior o en entorno difícil (polvos, líquidos u
otros agentes).
CONDICIONES ESPECIALES PARA UNA UTILIZACIÓN SEGURA
ATEX 94/9/CE :
El distribuidor debe tener toma a tierra (Ver
Montaje).
La temperatura máxima del fl uido no debe exceder la tem-
peratura ambiente.
En caso de almacenaje prolongado antes de la puesta en
marcha, el distribuidor debe permanecer en su embalaje
de origen. Los elementos de protección de los orifi cios de
racordaje y de las cabezas magnéticas deben permanecer
colocados.
Condiciones de almacenaje : al abrigo de intemperies; tem-
peratura : - 40°C a +70°C; humedad relativa : 95 %
Después de un almacenaje a baja temperatura, los distribui-
dores deben ser puestos progresivamente a la temperatura
ambiente de funcionamiento antes de la primera puesta bajo
presión.
Los distribuidores están diseñados para los campos de
funcionamiento indicados en la placa de características. No
puede realizarse ninguna modifi cación en el material sin el
acuerdo previo del fabricante o de su representante. Estos
distribuidores están previstos para funcionar con aire o
gases neutros fi ltrados. No sobrepasar la presión máxima
admisible = 10 bar (o 8 bar con piloto piezotronic ATEX Ex
ia). Respetar el valor mínimo de presión de pilotaje de 2 bar.
La puesta en marcha y el mantenimiento de estos productos
deben ser realizadas por personal competente.
Versiones de mando neumático standard IP65 o
previstas para atmósferas explosivas bajo forma de gas,
vapores, nieblas y polvos según la directiva ATEX 94/9/CE.
(La clasifi cación por zona de esta versión se defi ne por la
etiqueta ATEX, ref.E1).
Modo de protección, serie 551: II 1 GD c T6 T85°C Ta -40°C a +65°C
Modo de protección, serie 553: II 2 GD c T6 (T85°C) - T5 (T100°C)
Certifi cación CE : INERIS 03 ATEX 0219 X
El respeto de las exigencias esenciales en lo relativo a seguridad
y salud está asegurado por la conformidad a las normas europeas
EN 13463-1 y EN 13463-5.
Versiones con mando electroneumático equipadas con
cabezas magnéticas :
- estancas IP65 o certifi cadas para atmósferas explosivas
según la Directiva ATEX 94/9/CE
- Versiones cabezas magnéticas según plano de acopla-
miento ASCO, norma IP65 o para atmósferas explosivas,
II 3D IP65/IP67 o ATEX Ex d, m, em, Ex ia (serie 551: II
1G/2D Ex ia IIC IP65/IP67 o serie 553: II 2G/D Ex ia IIC
IP65/IP67).
- Versiones con pilotos, según plano de acoplamiento
CNOMO E06.05.80 (talla 30) o CNOMO E06.36.120N
(talla 15), norma IP 65 o montaje de pilotos para atmós-
feras explosivas ATEX, Ex d o Ex ia.
Atención (pilotos CNOMO) :
La colocación en zonas (ATEX
1999/92/CE), está defi nida prioritariamente por el marcaje
indicado en la etiqueta fi g. 10 y 20, (ref. E1 o E2) colocada
en el cuerpo del distribuidor. Modo de protección, según
ATEX 94/9/CE : II 1GD c T6 T85°C Ta -40°C a +65°C.
Certifi cación CE : INERIS 03 ATEX 0219 X
Tener en cuenta la categoría, rango de presión máxima
de funcionamiento y temperatura la menos favorable
durante el montaje con un piloto ATEX 94/9/CE. El
respeto de las exigencias esenciales en lo relativo a se-
guridad y salud está asegurado por la conformidad a las
normas europeas EN 13463-1 y EN 13463-5. Respete el
sentido de montaje de los pilotos indicado por las fi guras
4/5/14/15/21/22/23/24 y los pares de apriete indicados.
Para las cabezas magnéticas y pilotos ATEX 94/9/CE, siga
imperativamente las prescripciones de utilización descri-
tas en cada hoja de puesta en marcha específi ca provista
con el producto.
MONTAJE
!
Versiones ATEX 94/9/CE : Compruebe que todas las partes
metálicas o conductoras estén siempre interconectadas
y unidas a tierra. La unión a tierra del cuerpo de distribuidor
se realiza mediante el montaje del tornillo de fi jación (ref. F).
Los distribuidores pueden ser montados en cualquier posición.
Versiones roscadas 1/4 (fi g. 3a), 1/2 (fi g 3b) :
Montar el distribuidor con la ayuda de dos tornillos (ref.1), no
provistos.
Versiones con plano de acoplamiento NAMUR (fi g. 13a, 13b) :
Antes del montaje del distribuidor en el actuador, adapte el
aparato a la función deseada :
- Seleccione la placa interface correspondiente a la función
Instrucciones de puesta en marcha y mantenimiento
3/2 NC
ES
Distribuidores SERIE 551, cuerpo de latón, o SERIE 551-553, cuerpo de
acero inoxidable, roscado 1/4, 1/2 o con plano de acoplamiento NAMUR
5/2 - 5/3
Instrucciones de puesta en marcha y mantenimiento
3/2 NC
ES
Distribuidores SERIE 551, cuerpo de latón, o SERIE 551-553, cuerpo de
acero inoxidable, roscado 1/4, 1/2 o con plano de acoplamiento NAMUR
5/2 - 5/3
necesaria 3/2 NC o 5/2 (ref.1a o 1b).
-
Compruebe la presencia y correcta colocación de la junta de
forma (ref.7).
- Monte la placa bajo el distribuidor con la ayuda de los 2
tornillos (ref. 8) provistos, respetando el sentido de montaje:
la referencia de función debe estar colocada en el lado de
retorno (guía).
- Monte las dos juntas tóricas (ref.9).
- Coloque, si fuera necesario, la guía en el actuador :
• En la placa 3/2, el orifi cio guía Ø 5 está situado en A1.
• En la placa 5/2, el orifi cio guía Ø 5 está situado en A2.
RACORDAJE NEUMÁTICO (fi g. 3a, 3b, 13a y 13b)
Según la versión 3/2 NC o 5/2, se pueden adaptar uno o
dos protectores de escape de acero inoxidable, ver fi g. 2.
Racordaje del pilotaje versión neumática :
G 1/8 o NPT 1/8 o G 1/4 o NPT 1/4.
Racordaje de los escapes de pilotaje
Posibilidad de canalizar los escapes según las versiones.
Mando manual
Según las versiones los productos se suministran sin o con un man-
do manual, para funcionamiento sin tensión. Se indica mediante el
símbolo ( ), en las fi g. 4, 5, 14, 15, 21 a 24, y para la ref. 10 en las fi g.
3a, 3b, 13a, 14b.
El mando manual de impulsión o de posición mantenida
(tipo pulsar/girar), indicado por el símbolo ( ) en las fi g.
3a, 3b, 13a y 13b , permite el funcionamiento sin tensión.
!
Antes de cualquier operación de puesta en marcha,
compruebe el retorno a la posición "0" (no-enclavado) del
mando manual, para prevenir todo riesgo de accidente
corporal o material.
Adaptación en alimentación externa del pilotaje
(fi g.3a, 3b, 13a y 13b, ref.6)
Recomendaciones generales para racordaje neumático
Sostenga y alinee correctamente las tuberías para evitar
cualquier tensión mecánica en el distribuidor. Al apretar,
no utilice el aparato como palanca; Posicione las llaves
de apriete lo mas cerca posible del punto de racordaje.
Con el fi n de evitar deterioros, NO APRIETE DEMASIA-
DO los racores de las tuberías.
Versiones roscadas 1/4 (fi g. 3a, 1/2 (fi g 3b) :
Racordaje del distribuidor :
Racordar las tuberías en función de las referencias indi-
cadas en la etiqueta.
- Función 3/2 NC :
Entrada de presión por el orifi cio 1 (1/4 o 1/2). Utilización
por el orifi cio 2. Escape por el orifi cio 3 (1/4 o 1/2).
- Función 5/2 :
Entrada de presión por el orifi cio 1. Utilización por los
orifi cios 2 y 4.
Los escapes están canalizados hacia los orifi cios 3 y 5.
Versiones con plano de acoplamiento NAMUR (fi g 13a, 13b) :
Racordaje del distribuidor :
Racordar las tuberías en función de las referencias indi-
cadas en la etiqueta.
- Función 3/2 NC :
Entrada de presión por el orifi cio 1 (1/4 o 1/2). Utilización
por el orifi cio 2.
Escape por el orifi cio 3 (cuerpo de latón : 1/8;
cuerpo de acero inox : 1/4 o 1/2).
El escape de los alojamientos de los resortes de retorno
del actuador de simple efecto se canaliza a través del
distribuidor hacia el orifi cio 3 racordable. Se recomienda
proteger el orifi cio 5 (no utilizado) evitando obturarle.
- Función 5/2 :
Entrada de presión por el orifi cio 1 (1/4 o 1/2).
Utilización por los orifi cios 2 y 4.
Los escapes del actuador están canalizados a través del
distribuidor hacia los orifi cios 3 y 5 (cuerpo de latón : 1/8;
cuerpo de acero inox. : 1/4 o 1/2).
- Racordaje de los reductores de escape (cuerpo de
latón)
Según la demanda, los distribuidores serie 551 se sumi-
nistran sin o con reductores de escape miniatura 1/8, sufi jo
M (fi g. 13a).
Estos mini-reductores de escape regulables permiten
adaptar la velocidad de maniobra del actuador. También
se pueden racordar (rosca 1/8) para canalizar los escapes.
Montaje / Regulación (fi g. 3a) :
Versión 3/2 NC = 1 reductor para adaptar en el orifi cio 3
Versión 5/2 = 2 reductores para adaptar en los orifi cios 3 y 5
Apriete en el orifi cio el tornillo (4) del reductor hasta que
haga tope, después desatornille para aumentar el caudal
de escape sin sobrepasar las 2 vueltas (caudal máximo
obtenido a partir de 1 vuelta).
Bloquee la contra-tuerca (4a) con una llave plana de 13 mm.
La regulación debe realizarse sin presión, hay que afi narla
durante las pruebas con presión.
CONEXIÓN ELÉCTRICA
Versión con cabezas magnéticas interface ASCO :
Remitirse a la hoja de instalación complementaria provista
con cada cabeza magnética.
Cabeza magnética estanca IP65 (fi g. 3a, 3b, 13a y 13b) :
Adaptar la bobina en el tubo (orientable en 360°) después
el conector desenchufable ISO 4400/EN 175101-803A
(cable Ø6-10 mm), orientable en 90° x 90° (3 pines : 2 +
masa).
Versión con plano de acoplamiento CNOMO : Remi-
tirse a la hoja de instalación complementaria provista
con cada piloto.
Recomendaciones generales
La conexión eléctrica debe ser realizada por personal
cualifi cado y según las normas y reglamentos en vigor.
Atención :
- Antes de cualquier intervención, corte la alimentación
eléctrica para quitar la tensión de los componentes.
- Según la tensión, los componentes eléctricos deben tener
toma a tierra conforme a las normas y reglamentos locales.
La mayoría de los electrodistribuidores están provistos de
bobinados previstos para la puesta bajo tensión permanente.
Para evitar quemaduras, no toque la cabeza magnética
que, en funcionamiento normal y en permanencia bajo
tensión, puede alcanzar una temperatura elevada. Si el
electrodistribuidor es de fácil acceso, el instalador debe
prever una protección de la cabeza magnética.
MANTENIMIENTO
!
Antes de cualquier operación de mantenimiento o de
puesta en marcha, corte la alimentación del distribuidor,
despresurice y purgue,
para prevenir riesgos de accidente
corporal o material.
Versiones ATEX : Siga imperativamente durante la fase
de mantenimiento las recomendaciones de la Directiva
99/92/CE y normas asociadas
Limpieza
El mantenimiento de los distribuidores varia con sus
condiciones de utilización. Si fuese necesario, realizar
una limpieza periódica. Durante la intervención, los com-
ponentes deben ser examinados para detectar cualquier
desgaste excesivo. Cuando se observa un ralentizamiento
de la frecuencia aunque la presión de pilotaje sea correc-
ta o cuando se percibe un ruido anormal o una fuga, es
necesaria una limpieza.
Ruido de funcionamiento
El usuario solamente podrá determinar con precisión el nivel
sonoro emitido después de haber montado el componente
en la instalación. El ruido de funcionamiento varia según
la utilización, el fl uido y el tipo de material.
Mantenimiento preventivo
- Hacer funcionar el distribuidor al menos una vez al mes
para verifi car su apertura y su cierre.
- En caso de problemas durante el montaje/mantenimiento
o en caso de duda, contactar con ASCO Numatics o sus
representantes ofi ciales.
Consejos de reparación
- Presión de salida incorrecta : Comprobar la presión en
la entrada del distribuidor, esta debe corresponder a los
valores admitidos en la etiqueta de identifi cación. Atención,
respetar los valores mínimos de presión de pilotaje : 2 bar
Para prevenir cualquier riesgo de accidente personal o
material, comprobar que el distribuidor funciona correc-
tamente antes de la puesta en marcha.
Recambio
La bobina existe como pieza de recambio.
Si fuese necesario, cambiar el distribuidor completo.
11
10
3834901
3834901
DESCRIZIONE DELLA CERTIFICAZIONE
Versioni interessate dalla presente certifi cazione (fi g 1 e 11) :
Serie 551, corpo ottone, o Serie 551, 553, corpo acciaio
inox, monostabile (ritorno a molla) o bistabile, versione
3/2 NC (normalmente chiusa) o 5/2, versioni stagne
all'atmosfera. Versioni senza comando manuale o con
comando manuale :
- con raccordo fi lettato 1/4 (551) o 1/2 (553)
- 551, profondità
massima della porta 11,5 mm. (Non connettere l’ingresso
della pressione alla porta di scarico 3. La costruzione “a
protezione dell’ambiente” non è adatta da una funzione di
“distribuzione” o a un impiego senza NESSUNA funzione.
Mettersi in contatto con noi per le funzioni disponibili in
versioni specifi che).
- con piano di posa secondo raccomandazioni NAMUR
per montaggio diretto su attuatore pneumatico a semplice
effetto (funzione 3/2 NC) o doppio effetto (funzione 5/2).
Uno stesso distributore si adatta alle due funzioni mediante
posizionamento sulla parte inferiore di una delle due piastre
interfaccia 3/2 NC o 5/2 fornite (fi g. 13a, 13b, rif. 1a e 1b. 551,
profondità massima della porta 11,5 mm(
Non connettere
l’ingresso della pressione alla porta di scarico 3. La co-
struzione “a protezione dell’ambiente” non è adatta a un
impiego senza NESSUNA funzione.
Mettersi in contatto
con noi per le funzioni disponibili in versioni specifi che).
- Raccordare le tubazioni secondo le funzioni desiderate,
tenendo conto dei riferimenti delle vie marcati sul prodotto
e nella presente documentazione.
- Controllare che nessun corpo estraneo penetri all'interno del
circuito, onde evitare il blocco della valvola. Limitare l'utilizzo
di nastro o pasta per tenute.
- I distributori ed elettrodistributori devono essere utilizzati solo
con aria pulita e secca, o con gas neutro. Si raccomanda un
ltraggio minimo di 50 micron. Il punto di rugiada dei fl uidi
deve essere di almeno -10°C (18°F) al di sotto della tempe-
ratura minima a cui i fl uidi possono essere esposti. Se viene
usata aria lubrifi cata, il lubrifi cante deve essere compatibile
con gli elastomeri usati. La qualità "aria strumenti" defi nita
dalla norma ANSI/ISA S7.3 (1975) supera i requisiti ed è
pertanto un supporto accettabile per queste valvole.
!
Tutte le connessioni di scarico delle valvole e dei piloti devono
essere protette con silenziatori in acciaio inox. Colle-
gare i silenziatori alla connessione (3/2 NC) o connessioni
3-5 (5/2). Per utilizzo esterno, o in giacenza a magzzino
per lunghi periodi, e/o esposte in ambienti diffi cili (pol-
veri, liquidi, ecc.), devono essere utilizzati i silenziatori.
L'affi dabilità della valvola non viene garantita nel caso di
utilizzo di un silenziatore differente da quello prescritto.
- Campo di temperatura autorizzato: da -40°C a +80°C (serie
551); da -40°C a +60°C (serie 553).
- Campo di pressione max di funzionamento:
- da 2 a 10 bar
- da 2 a 8 bar
(ISSC/PISC/PISCIS/CFSCIS/CFSDIS/CFVTIS)
DESCRIZIONE GENERALE
Versioni ATEX 94/9/CE : Vedere "condizioni speciali per un
utilizzo sicuro".
Versioni stagne all'atmosfera : I componenti interni del
distributore sono isolati dall'atmosfera esterna, quindi protetti
dagli ambienti aggressivi. Tutte le vie di scarico se cana-
lizzate, assicurano una migliore protezione dagli ambienti
aggressivi, particolarmente raccomandata per installazioni
in zone sensibili come sale bianche, industrie farmaceutiche
o agroalimentari. E' necessario canalizzare o predisporre gli
scarichi per proteggere i componenti interni del distributore
in caso di utilizzo all'esterno o in ambiente diffi cile (polveri,
liquidi o altri agenti).
CONDIZIONI SPECIALI PER UN UTILIZZO SICURO
ATEX 94/9/CE : Il distributore deve avere la messa a terra (Vedere
Montaggio).
La temperatura max del fl uido non deve superare la tempe-
ratura ambiente.
In caso di stoccaggio prolungato prima della messa in funzio-
ne, il distributore deve restare nel suo imballaggio d'origine.
Gli elementi di protezione delle vie di raccordo e delle teste
magnetiche devono rimanere al proprio posto.
Condizioni di stoccaggio: al riparo dalle intemperie; tempera-
tura : da - 40°C a +70°C; umidità relativa : 95 %
Dopo uno stoccaggio a bassa temperatura, i distributori
devono essere riportati progressivamente alla temperatura
ambiente di funzionamento prima di essere messi in pressione
per la prima volta.
I distributori sono progettati per i campi di funzionamento
indicati sulla etichetta di segnalazione. Nessuna modifi ca
può essere apportata sui materiali senza il previo accordo
del fabbricante o dei suoi rappresentanti. Questi elettrodi-
stributori sono previsti per aria o gas neutri fi ltrati. Non
superare la pressione max ammessa = 10 bar (o 8 bar con
pilota piezotronic ATEX Ex ia). Rispettare il valore minimo
di funzionamento di 2 bar. La messa in funzione di questi
prodotti deve essere effettuata da personale competente
Versioni a comando pneumatico standard IP65 o previste
per atmosfere pericolose come gas, vapori, nebbie
e polveri secondo la Direttiva ATEX 94/9/CE.
La clas-
sifi cazione delle zone di questa versione è defi nita
nell'etichetta ATEX, rif.E1).
Modo di protezione, serie 551: II 1 GD c T6 T85°C Ta da -40°C
a +65°C
Modo di protezione, serie 553: II 2 GD c T6 (T85°C) - T5 (T100°C)
Certifi cato di esame CE di tipo (serie 551):
INERIS 03 ATEX 0219 X
Il rispetto dei requisiti essenziali in materia di sicurezza e
salute è assicurata dalla conformità alle norme europee EN
13463-1 e EN 13463-5.
Versioni a comando elettropneumatico dotate di teste
magnetiche:
- protezione IP65 o omologate per atmosfere pericolose
secondo la Direttiva ATEX 94/9/CE
- Versioni con teste magnetiche secondo piano di
posa ASCO, standard IP65 o per atmosfere pericolose,
II 3D IP65/IP67 o ATEX Ex d, m, em, Ex ia (serie 551: II
1G/2D Ex ia IIC IP65/IP67 o serie 553: II 2G/D Ex ia IIC
IP65/IP67).
- Versioni con piloti, secondo piano di posa CNOMO
E06.05.80 (taglia 30) o CNOMO E06.36.120N (taglia
15), standard IP 65 o montaggio di piloti per atmosfere
pericolose ATEX, Ex d o Ex ia.
Attenzione (piloti CNOMO) : L'installazione in zone
(ATEX 1999/92/CE), è determinato in via prioritaria dal-
la marcatura indicata sull'etichetta (fi g. 10 e 20, rif. E1
o E2) situata sul corpo del distributore. Modo di prote-
zione secondo
ATEX 94/9/CE : II 1 GD c T6 T85°C Ta da
-40°C a +65°C.
Certifi cato di esame CE di tipo : INERIS 03 ATEX 0219 X
Considerare la categoria, pressione massimo di fun-
zionamento e la temperatura meno favorevoli quan-
do si monta un gruppo con pilota ATEX 94/9/CE. Il
rispetto dei requisiti essenziali in materia di sicurezza e
salute è assicurato dalla conformità alle norme europee
EN 13463-1 e EN 13463-5. Rispettare il senso di montaggio
dei piloti indicato nelle fi gure dalla 4/5/14/15/21/22/23/24 e
le coppie di serraggio indicate.
Per le teste magnetiche ed i piloti ATEX 94/9/CE, seguire
tassativamente le istruzioni per l'uso riportate nelle ri-
spettive avvertenze specifi che per la messa in funzione
fornite con il prodotto.
MONTAGGIO
!
Versioni ATEX 94/9/CE : Accertarsi che tutte le parti
metalliche o conduttrici siano sempre interconnesse e messe
a terra. La messa a terra del corpo del distributore si esegue
montando la vite di fi ssaggio (rif. F).
I distributori possono essere montati in qualsiasi posizione.
Versioni fi lettate 1/4 (fi g. 3a); 1/2 (fi g. 3b) :
Montare il distributore servendosi di due viti (rif.1), non com-
prese nella fornitura.
Versioni con piano di posa NAMUR (fi g. 13a, 13b) :
Prima di montare il distributore sull'attuatore, adattare il
componente alla funzione scelta :
- Selezionare la piastra interfaccia sulla funzione desidera-
ta 3/2 NC o 5/2 (rif.1a o 1b).
- Verifi care la presenza e l'inserimento corretto della guarni-
zione sagomata (rif.7).
- Assemblare piastra e distributore con le 2 viti (rif.8) fornite,
rispettando il senso di montaggio: il riferimento della funzione
Istruzioni di installazione e manutenzione
3/2 NC
IT
Distributori SERIE 551, corpo ottone, o SERIE 551-553, corpo
acciaio inox, lettati 1/4 o 1/2, o a piano di posa NAMUR
5/2 - 5/3
deve essere posizionato lato ritorno (spina di riferimento).
- Montare le due guarnizioni OR (rif.9).
- Posizionare, se necessario, la spina di riferimento sull'at-
tuatore :
Sulla piastra 3/2, la spina di riferimento Ø 5 è situata in A1.
Sulla piastra 5/2, la spina di riferimento Ø 5 è situata in A2.
RACCORDO PNEUMATICO (fi g. 3a, 3b 13a, 13b)
A seconda della versione 3/2 NC o 5/2, vengono fornite una
o due protezioni di scarico in acciaio inox (vedere fi g. 2).
Raccordo di pilotaggio automatico :
G 1/8 o NPT 1/8 o G 1/4 o NPT 1/4.
Raccordo degli scarichi di pilotaggio
Possibilità di raccogliere gli scarichi secondo la versione.
Comando manuale
A seconda delle versioni i prodotti sono forniti con o senza
comando manuale, per funzionamento senza tensione.
Essa è segnalata dal simbolo ( ) sulle fi g. 4, 5, 14, 15, da
21 a 24, e dal rif. 10 sulle fi g. 3a, 3b, 13a, 13b.
Il comando manuale ad impulsi o posizione mantenuta (tipo
spingere/girare), segnalata dal simbolo ( ) sulle fi g. 3a,
3b, 13a e 13b, permette il funzionamento senza tensione.
!
Prima di qualsiasi operazione di rimessa in funzione,
convalidare il ritorno sulla posizione "0" (non-inserita)
del comando manuale, per evitare qualsiasi rischio di
incidente a cose o persone.
Montaggio con alimentazione esterna di pilotaggio
(fi g.3a, 3b, 13a e 13b, rif.6)
Raccomandazioni generali per il raccordo pneumatico
Supportare ed alimentare correttamente le tubazioni per
evitare qualsiasi sollecitazione meccanica sul distributore.
Serrando, non servirsi dell'apparecchio come se fosse una
leva; posizionare le chiavi di serraggio il più vicino possibile
al punto di raccordo. Per evitare qualsiasi guasto, NON
SERRARE TROPPO i raccordi delle tubazioni.
Versioni fi lettate 1/4 (fi g. 3a); 1/2 (fi g 3b):
Raccordo del distributore:
Collegare le tubazioni secondo i riferimenti indicati sull'eti-
chetta.
- Funzione 3/2 NC :
Ingresso della pressione attraverso della via 1 (1/4 o 1/2).
Utilizzo attraverso la via 2. Scarico attraverso la via 3 (1/4
o 1/2)
- Funzione 5/2 :
Ingresso della pressione attraverso la via 1. Utilizzo attra-
verso le vie 2 e 4.
Gli scarichi sono incanalati verso le vie 3 e 5.
Versioni con piano di posa NAMUR (fi g 13a, 13b) :
Raccordo del distributore:
Collegare le tubazioni secondo i riferimenti indicati sull'eti-
chetta.
- Funzione 3/2 NC :
Ingresso della pressione attraverso la via 1 (1/4 o 1/2).
Utilizzo attraverso la via 2. Scarico attraverso la via 3
(corpo in ottone: 1/8; corpo in acciaio inox: 1/4 o 1/2).
Lo scarico delle camere delle molle di ritorno dell'attuatore
a semplice effetto è canalizzato attraverso il distributore
verso la connessione 3 raccordabile. Si raccomanda di
proteggere la via 5 (non utilizzata) evitando di tapparla.
- Funzione 5/2 :
Ingresso della pressione attravero la via 1 (1/4 o 1/2).
Utilizzo attraverso le vie 2 e 4.
Gli scarichi dell'attutore sono incanalati verso le vie 3 e
5 (corpo in ottone: 1/8; corpo in acciaio inox : 1/4 o 1/2).
- Raccordo dei regolatori di scarico (corpo ottone)
A seconda della richiesta, i distributori serie 551 sono forniti
con o senza regolatori di scarico miniaturizzati 1/8, suffi sso
M (fi g. 13a).
Tali mini-regolatori di scarico regolabili permettono di adat-
tare la velocità di manovra dell'attuatore. Sono ugualmente
raccordabili (fi lettatura 1/8) per collegare gli scarichi.
Montaggio / Regolazione (fi g. 3a) :
Versione 3/2 NC = 1 regolatore da montare sulla via 3
Versione 5/2 = 2 regolatore da montare sulle vie 3 e 5
Serrare la vite nella via (4) del regolatore fi no ad arresto
battuta, poi svitare per aumentare la portata dello scarico
senza mai superare i 2 giri (la portata max si ottiene a
partire da 1 giro).
Bloccare il contro-dado (4a) mediante chiave da 13 mm.
La regolazione deve essere effettuata in assenza di pres-
sione, l'ottimizzazione effettuando delle prove dopo la
pressurizzazione.
CONNESSIONE ELETTRICA
Versione con testa magnetica interfaccia ASCO : fare
riferimento alle istruzioni d'installazione complementari
fornite con ciascuna testa magnetica.
Testa magnetica con protezione IP65 (fi g. 3a, 3b, 13a e
13b) : Montare la bobina sul tubo (orientabile a 360°) poi il
connettore disinnestabile ISO 4400/EN 175101-803A (cavo
Ø6-10 mm), orientabile a 90° (3 morsetti : 2 + massa).
Versione a piano di posa CNOMO: fare riferimento
alle istruzioni d'installazione complementari fornite con
ciascun pilota.
Raccomandazioni generali
Il collegamento elettrico deve essere realizzato da personale
qualifi cato e secondo le norme ed i regolamenti in vigore.
Attenzione:
- Prima di qualsiasi intervento, togliere l'alimentazione
elettrica per mettere i componenti fuori tensione.
- A seconda della tensione, i componenti elettrici devono
essere messi a terra in conformità alle norme ed i regola-
menti locali.
La maggior parte dei distributori hanno bobine previste
per messa in tensione permanente. Per evitare bruciature,
non toccare la testa magnetica che, in funzionamento nor-
male e permanentemente sotto tensione, può raggiungere
una temperatura elevata. Se l'elettrovalvola è facilmente
accessibile, l'installatore deve prevedere una protezione
della testa magnetica.
MANUTENZIONE
!
Prima di qualsiasi operazione di manutenzione o di
rimessa in funzione, togliere l'alimentazione al distributore,
depressurizzare e spurgare,
per evitare qualsiasi rischio di
incidente a cose o persone.
Versioni ATEX : in fase di manutenzione seguire tassa-
tivamente le raccomandazioni della direttiva 99/92/CE e
norme associate.
Pulizia
La manutenzione dei distributori varia secondo le loro
condizioni di impiego. Se necessario, procedere ad una
pulizia periodica. Quando si segue un intervento, si devono
esaminare i componenti per individuare i punti troppo usurati.
E' necessaria una pulizia quando si osserva un rallentamento
della cadenza, pur essendo corretta la pressione di pilotaggio
o quando si sente un rumore anomalo o si constata una fuga.
Rumore di funzionamento
L’utente potrà determinare con precisione il livello sonoro am-
messo solo dopo avere montato il componente sull’installazione.
Il rumore di funzionamento varia secondo l’uso, il fl uido ed il tipo
di materiale.
Manutenzione preventiva
- Fare funzionare il distributore almeno una volta al mese
per verifi carne l'apertura e la chiusura.
- In caso di problema al montaggio o alla manutenzione
o in caso di dubbio, contattare ASCO Numatics o i suoi
rappresentanti uffi ciali.
Consigli per la riparazione
Pressione di uscita anomala: verifi care la pressione all’en-
trata del distributore; deve corrispondere ai valori ammessi
sull'etichetta dati.
Attenzione. Rispettare i valori minimi di pressione di pilotag-
gio: 2 bar.
Per evitare qualsiasi rischio d’incidente a cose o persone,
verifi care che il distributore funzioni correttamente prima di
rimetterlo in servizio.
Ricambi
La bobina viene proposta come parte di ricambio. Se neces-
sario, sostituire l'elettrodistributore o il distributore completo.
Istruzioni di installazione e manutenzione
3/2 NC
IT
Distributori SERIE 551, corpo ottone, o SERIE 551-553, corpo
acciaio inox, lettati 1/4 o 1/2, o a piano di posa NAMUR
5/2 - 5/3
13
12
3834901
3834901
OMSCHRIJVING VAN DE GOEDKEURING
Versies waar de goedkeuring betrekking op heeft (afb. 1
en 11):
Dit zijn monostabiele (met terugstelveer) of bistabiele
magneetafsluiters met een afsluiterhuis van messing
(551-serie) of van roestvast staal (series 551, 553), met
3/2 NC- (normaal gesloten) of 5/2-werking in een van de
buitenlucht geïsoleerde uitvoering. Versies met en zonder
handmatige bediening:
- met ¼” (551) of ½” (553) schroefdraadaansluitingen
- 551,
met ¼” getapte aansluiting max. poortdiepte 11,5 mm.
(Sluit de druktoevoer niet aan op ontluchtingspoort 3. De
“hermetisch afgedichte" constructie is niet geschikt als
"verdeelfunctie" of voor gebruik in NO functie. Speciale
uitvoeringen op aanvraag).
- met NAMUR-aansluiting voor directe montage op enkel-
werkende (3/2 NC) of dubbelwerkende (5/2) pneumatische
actuatoren. De werking van de afsluiter kan van 3/2 NC naar
5/2 worden omgebouwd door de meegeleverde 3/2 NC- of
5/2-functieplaat onder de afsluiter te monteren (fi g.13a, 13b,
zie 1a en 1b). 551, Met ¼” max. poortdiepte 11,5 mm.
(
Sluit de druktoevoer niet aan op ontluchtingspoort 3.
De “hermetisch afgedichte" constructie is niet geschikt
voor gebruik in NO functie.
Speciale uitvoeringen op
aanvraag).
- Neem bij het aansluiten van de benodigde leidingen voor
de gewenste functie de aanwijzingen in dit document en de
poortmarkeringen op het product in acht.
- Zorg dat er geen vuil in de leidingen kan komen, om schade
aan de afsluiter te voorkomen. Beperk het gebruik van af-
dichttape en afdichtingsmateriaal tot een minimum.
- Deze afsluiters zijn bedoeld voor gebruik met schone en droge
lucht of inert gas. Aanbevolen fi ltratieminimum: 50 micron.
Het dauwpunt van het gebruikte medium dient minstens
10°C onder de minimumtemperatuur te liggen waaraan het
medium ooit zal worden blootgesteld. Indien gesmeerde
lucht wordt gebruikt, dient het smeermiddel geschikt te zijn
voor de gebruikte elastomeren. Instrumentatielucht conform
ANSI/ISA norm S7.3 (1975) voldoet ruimschoots aan deze
vereisten en is daardoor een geschikt medium voor deze
afsluiters.
!
Alle uitlaatpoorten van de afsluiters en stuurkleppen
moeten worden beschermd met roestvaststalen
uitlaatbeschermers. Sluit de uitlaatbeschermers aan
op poort 3 (3/2 NC) of poorten 3 - 5 (5/2). Bij gebruik
buiten of opslag voor langere tijd en/of bij blootstelling
aan veeleisende omgevingen (stof, vloeistoffen, enz.)
moeten uitlaatbeschermers worden gebruikt. De betrouw-
baarheid van de afsluiter kan niet worden gegarandeerd
indien een uitlaatbescherming anders dan de geleverde
bescherming wordt gebruikt.
- Toegestaan temperatuurbereik:
-40°C tot +80°C (serie 551); -40°C tot +60°C (serie 553).
- Maximale werkdruk:
- 2 tot 10 bar
- 2 tot 8 bar
(ISSC/PISC/PISCIS/CFSCIS/CFSDIS/CFVTIS)
BESCHRIJVING
ATEX 94/9/EG-versies: Zie "Speciale voorwaarden voor
veilig gebruik".
Versies die geïsoleerd zijn van de buitenlucht: De inwen-
dige delen van de afsluiter zijn geïsoleerd van de buitenlucht,
voor bescherming in schadelijke omgevingen. Op alle uitlaat-
openingen van deze schuifafsluiter kunnen leidingen worden
aangesloten, zodat ze optimaal kunnen worden afgeschermd
van hun omgeving en van het milieu. Daardoor zijn ze met
name geschikt voor installaties in gevoelige omgevingen zoals
in stofvrije ruimten, in de farmaceutische industrie en in de
voedingsmiddelenindustrie. Bij gebruik in de buitenlucht en bij
gebruik in veeleisende omgevingen (stof, dampen, enz.) moet
u leidingen of appendages op de uitlaatpoorten aansluiten
om de inwendige delen van de schuifafsluiter te beschermen.
SPECIALE VOORWAARDEN VOOR VEILIG GEBRUIK
ATEX 94/9/EG-versies: De afsluiter moet worden geaard (zie
"Montage").
De maximale temperatuur van het medium mag de omge-
vingstemperatuur niet overschrijden.
Bewaar de schuifafsluiter in zijn originele verpakking zolang u
hem niet gebruikt. Laat de bescherming op de aansluitpoorten
en over de magneetkoppen zitten.
Opslageisen: beschermen tegen weersinvloeden, opslag-
temperatuur: -40ºC tot + 70ºC; relatieve vochtigheid: 95%
Na opslag bij een lage temperatuur dienen de schuifaf-
sluiters geleidelijk aan op gebruikstemperatuur te worden
gebracht voordat ze onder druk worden gezet.
De schuifafsluiters mogen uitsluitend toegepast worden bin-
nen de op het typeplaatje aangegeven specifi caties. Wijzi-
gingen zijn alleen toegestaan na overleg met de fabrikant of
haar vertegenwoordiger. Deze magneetafsluiters van het
schuiftype zijn ontworpen op het gebruik van gefi lterde
lucht of neutrale gassen. Overschrijd nooit de maximaal
toegestane druk van de afsluiter = 10 bar (of 8 bar met een
Piezotronic-stuurklep conform ATEX Ex ia). Zorg voor een
minimale stuurdruk van 2 bar. Alleen vakkundig personeel
mag de afsluiter installeren en onderhouden.
Standaard pneumatisch bediende versies in IP65-klasse
of versies voor gebruik in explosiegevaarlijke omgevingen
veroorzaakt door gassen, dampen, mist of stof volgens
ATEX-richtlijn 94/9/EG. (De zoneclassifi catie voor deze
versies staat op het ATEX-label, zie E1).
Veiligheidscode, serie 551: II 1 GD c T6 T85°C Ta -40°C tot +65°C.
Veiligheidscode (553-serie): II 2 GD c T6 (T85°C) - T5 (T100°C)
EG-typegoedkeuring nr. (serie 551): INERIS 03 ATEX 0219 X
Dit product voldoet aan de Europese normen EN 13463-1
en EN 13463-5, en daarmee ook aan alle wettelijke arbo-
voorschriften.
Pneumatisch werkende magneetafsluiters met magneet-
koppen:
- IP65-klasse of gecertifi ceerd voor gebruik in explosiege-
vaarlijke omgeving volgens ATEX-richtlijn 94/9/EG.
Versies met magneetkoppen met ASCO-montageplaat
- standaard IP65 of voor gebruik in een explosiegevaarlijke
omgeving II 3D IP65/IP67 of ATEX Ex d, m, em, Ex ia (Serie
551: II 1G/2D Ex ia IIC IP65/IP67 of serie 553: II 2G/D Ex
ia IIC IP65/IP67).
Versies met stuurkleppen met montageplaat CNOMO
E06.05.80 (grootte 30) of CNOMO E06.36.120N (grootte 15)
- standaard IP65 of stuurkleppen voor gebruik in explosiege-
vaarlijke omgevingen volgens ATEX Ex d of Ex ia.
Let op (CNOMO-stuurkleppen): De zoneclassifi catie
(ATEX 1999/92/EG) wordt in eerste instantie bepaald
door de vermelding op het typeplaatje fi g. 10 en 20 (zie
E1 of E2) op het huis van de afsluiter. Veiligheidscode
volgens ATEX-richtlijn 94/9/EG: II 1 GD c T6 T85°C Ta
-40°C tot +65°C
EG-typegoedkeuring certifi caat-nr.: INERIS 03 ATEX 0219 X
Neem bij het monteren van dit product op een stuurklep
volgens ATEX 94/9/EG de minst gunstige categorie, maxi-
male werkdruk en temperatuur in acht. Dit product voldoet
aan de Europese normen EN 13463-1 en EN 13463-5, en
daarmee ook aan alle wettelijke arbo-voorschriften. Neem
de montagerichting voor de stuurkleppen zoals aangeduid in
guren 4/5/14/15/21/22/23/24 in acht, evenals de genoemde
aandraaimomenten.
Neem bij magneetkoppen en stuurkleppen die voldoen
aan ATEX 49/9/EG altijd de gebruiksvoorschriften in acht
die in de handleiding van het product staan vermeld.
MONTAGE
!
ATEX 94/9/EG-versies: Zorg dat alle metalen en ge-
leidende onderdelen altijd op elkaar zijn aangesloten en
geaard zijn. Het afsluiterhuis is via de bevestigingsschroef
(zie F) geaard.
De afsluiters mogen in alle standen worden gemonteerd.
Versies met schroefdraadaansluitingen ¼” (fi g. 3a), ½”
(fi g. 3b):
Monteer de afsluiter met behulp van twee bouten (zie 1) (niet
bij levering inbegrepen).
Versies met NAMUR-aansluiting (fi g. 13a, 13b):
Kies de gewenste werking voordat u de schuifafsluiter monteert:
- Kies de functieplaat die correspondeert met de gewenste
functie : 3/2 NC of 5/2 (zie 1a of 1b).
- Zorg voor correcte plaatsing van de afdichting (zie.7)
- Monteer de functieplaat met behulp van de 2 meegeleverde
bouten (zie 8) onder de schuifafsluiter. De functie-indicatie
moet zich aan de retourzijde (codering) bevinden.
ALGEMENE INSTALLATIE- EN ONDERHOUDSINSTRUCTIES
3/2 NC
NL
Magneetafsluiters uit de 551-serie met messing huis, of uit de 551-/553-serie met roest-
vaststalen huis, en voorzien van ¼”- of ½”-schroefdraad of een NAMUR-aansluiting
5/2 - 5/3
- Plaats de 2 O-ringen (zie 9).
- Plaats, indien nodig, de positioneerstift op de kop:
Op de 3/2 NC-functieplaat bevindt de centreeropening Ø 5 zich
bij A1.
Op de 5/2-functieplaat bevindt de centreeropening Ø 5 zich
bij A2.
PNEUMATISCHE AANSLUITING (fi g. 3a, 3b, 13a en 13b)
Afhankelijk van de versie (3/2 NC of 5/2), kunnen één of twee
roestvaststalen uitlaatbeschermers worden gebruikt (zie fi g. 2).
Aansluiting van de pneumatisch gestuurde versie:
G 1/8 of NPT 1/8 of G 1/4 of NPT 1/4.
Aansluiting van de stuuruitlaten
De uitlaatgassen kunnen worden opgevangen, afhankelijk
van de gebruikte afsluiterversie.
Handmatige bediening
Afhankelijk van de versie worden de producten geleverd
met of
zonder handmatige bediening om ook te werken
zonder stroom. De handmatige bediening wordt aangegeven
met het symbool ( ), in fi g. 4, 5, 14, 15, 21 t/m 24, en zie 10
in fi g. 3a, 3b, 13a, 13b.
Het type handbediening, impulstype of van schakeltype
(duw-/draaitype), wordt aangeduid door het symbool ( )
in fi g. 3a, 3b, 13a en 13b. Beide typen maken stroomloze
bediening mogelijk.
!
Controleer vóór iedere inbedrijfstelling of de hand-
matige bediening is teruggezet op diens gedeactiveerde
stand "0", teneinde elk risico op persoonlijk letsel en op
beschadiging van de apparatuur te vermijden.
Aanpassing aan externe stuurvoorziening
(fi g.3a, 3b, 13a en 13b, zie 6)
Algemene aanbevelingen voor pneumatische aanslui-
tingen
De leidingen moeten correct worden ondersteund en uit-
gelijnd om elke mechanische belasting van de afsluiter te
vermijden. Bij het vastschroeven mag u de afsluiter niet
als hefboom gebruiken. Plaats gereedschappen zo dicht
mogelijk bij de te maken verbinding. Gebruik een zodanig
koppel voor leidingverbindingen dat het product NIET
WORDT BESCHADIGD.
Versies met schroefdraadaansluitingen ¼” (fi g. 3a), ½”
(fi g. 3b):
Aansluiten van de schuifafsluiter:
Sluit de leidingen aan zoals aangegeven op het typeplaatje.
- Werking 3/2 NC:
Drukinlaat via poort 1 (met ¼”- of ½”-schroefdraad).
Drukuitlaat via poort 2.
Uitlaat via poort 3 (met ¼”- of ½”-schroefdraad).
- Werking 5/2:
Drukinlaat via poort 1. Drukuitlaat via de poorten 2 en 4.
De uitlaten van de afsluiter worden naar de poorten 3
en 5 geleid.
Versies met NAMUR-aansluiting (fi g 13a, 13b):
Aansluiting van de schuifafsluiter:
Sluit de leidingen aan zoals aangegeven op het typeplaatje.
- Werking 3/2 NC:
Drukinlaat via poort 1 (met ¼”- of ½”-schroefdraad).
Drukuitlaat via poort 2.
Uitlaat via poort 3 (messing huis: 1/8 ; roestvaststalen
huis: 1/4" of 1/2" schroefdraad).
De afsluiter leidt de uitlaat van de terugstelveerkamers
bij enkelvoudige werking naar poort 3. We raden u aan
om poort 5 (niet gebruikt) af te schermen, maar niet af
te sluiten.
- Werking 5/2:
Drukinlaat via poort 1 (met ¼”- of ½”-schroefdraad).
Drukuitlaat via de poorten 2 en 4.
De afsluiter leidt de uitlaten naar de poorten 3 en 5
(messing huis: 1/8 ; roestvaststalen huis: 1/4" of 1/2"
schroefdraad).
Aansluiting van uitlaatverloopstukken (messing huis):
Schuifafsluiters uit de serie 551 worden conform bestelling
geleverd met of zonder 1/8" miniatuur-uitlaatverloopstukken,
achtervoegsel M (fi g. 13a).
Deze instelbare mini-uitlaatverloopstukken worden gebruikt
om de bedrijfssnelheid van de actuator aan te passen. Ze
kunnen ook worden aangesloten (1/8" schroefdraad) om
de uitlaatgassen op te vangen.
Monteren / instellen (fi g. 3a):
Versie 3/2 NC = 1 uitlaatverloopstuk moet worden gemonteerd
aan poort 3.
Versie 5/2 = 2 uitlaatverloopstukken dienen te worden
gemonteerd aan poorten 3 en 5
Duw de schroef (4) op het verloopstuk in het gat en schroef
hem vast tot tegen de aanslag; draai hem vervolgens losser
om de uitlaatstroom te verhogen (nooit meer dan twee
slagen, max. doorstroom verkregen bij één slag).
Draai de borgmoer (4a) vast met een sleutel van 13 mm.
Voer een ruwe afstelling uit voordat de druk wordt aange-
bracht en voer een fi jnafstelling uit na het onder druk brengen.
ELEKTRISCHE AANSLUITING
Versie met magneetkoppen met ASCO-aansluiting:
Zie de aanvullende installatie-instructies die bij elke
magneetkop worden meegeleverd.
IP65-magneetknop (fi g. 3a, 3b en 13a, 13b): Monteer de
eerst spoel op de buis (360° draaibaar) en daarna de los-
neembare ISO 4400/EN 175101-803A aansluiting (kabel-
diam. 6-10 mm) draaibaar over 90° (3 pennen: 2 + aarde).
Versies met CNOMO-montageplaat:
Zie de aanvullende installatie-instructies die worden
geleverd met elke stuurklep.
Algemene aanbevelingen:
De elektrische aansluiting dient te gebeuren door een vak-
man en in overeenstemming met de geldende voorschriften
en normen.
Let op:
- Voordat men aan het werk begint, moeten alle spanning-
voerende delen spanningsloos worden gemaakt.
- Afhankelijk van de spanning moeten de elektrische com-
ponenten eventueel worden geaard volgens de lokaal
geldende wet- en regelgeving.
De meeste afsluiters zijn uitgerust met spoelen voor continu
gebruik. Om elk risico op lichamelijk letsel te vermijden, dient
men aanraking van de magneetkop te voorkomen omdat
die bij normaal gebruik heet kan worden. In voorkomende
gevallen dient men de magneetkop af te schermen voor
aanraking.
ONDERHOUD
!
Voor de inbedrijfname en voordat u begint aan onder-
houdswerk moet u de elektrische voeding uitschakelen en de
afsluiter drukloos maken om elk risico op het ontstaan van
persoonlijk letsel of materiële schade te vermijden.
ATEX-versies: neem alle voorschriften conform de Euro-
pese richtlijn 99/92/EG en de hiervan afgeleide normen
strikt in acht.
Reiniging
Hoeveel onderhoud de afsluiters vereisen, hangt af van de
gebruiksomstandigheden. Zorg voor regelmatig onderhoud.
Controleer tijdens het onderhoud of onderdelen zijn versleten.
Een reinigingsbeurt is nodig wanneer werkritme vertraagt
terwijl de stuurdruk correct is, of wanneer een abnormaal
geluid of lek wordt waargenomen.
Geluidsniveau
De geluidsemissie hangt sterk af van de toepassing, en
van het gebruikte medium en de apparatuur. De bepaling
van het geluidsniveau kan pas uitgevoerd worden nadat de
afsluiter is ingebouwd.
Preventief onderhoud
- Gebruik de afsluiter ten minste één keer per maand om
de werking ervan te controleren.
- In geval van problemen of als er onduidelijkheden tijdens
montage, gebruik of onderhoud optreden, neem dan con-
tact met ons op of met één van onze vertegenwoordigers.
Storingen verhelpen
- Verkeerde uitlaatdruk: Controleer de druk aan de inlaat-
zijde van de afsluiter, deze moet overeenstemmen met
de specifi caties op het typeplaatje.
Let op: zorg voor een minimale stuurdruk van 2 bar.
Controleer of de afsluiter correct werkt voordat u hem
opnieuw in bedrijf stelt, om zo elk risico op lichamelijk
letsel of materiële schade te vermijden.
Reserveonderdelen
De spoel is verkrijgbaar als reserveonderdeel.
Vervang zo nodig de gehele afsluiter.
ALGEMENE INSTALLATIE- EN ONDERHOUDSINSTRUCTIES
3/2 NC
NL
Magneetafsluiters uit de 551-serie met messing huis, of uit de 551-/553-serie met roest-
vaststalen huis, en voorzien van ¼”- of ½”-schroefdraad of een NAMUR-aansluiting
5/2 - 5/3
15
14
3834901
3834901
BESKRIVELSE AV GODKJENNELSEN
Versjoner som godkjennelsen gjelder (fi g. 1 og 11):
Kun hus av messing (serie 551) eller rustfritt stål (serie
551, 553), monostabil (fjærretur) eller bistabil, 3/2 NC
(normalt lukket) funksjon eller 5/2, versjon isolert fra den
utvendige atmosfæren. Versjoner uten manuell oversty-
ring eller med manuell overstyring av impulstypen:
- med gjengede 1/4 (551) eller 1/2 (553) porter - 551, med
1/4" gjenget kobling, maks. portdybde 11,5 mm. (Ikke
koble trykktilførselen til utblåsningsåpning 3. Den
“miljøvennlige” konstruksjonen er ikke tilpasset en
“distribusjons”-funksjon eller bruk i NO-funksjon. Ta
kontakt med oss for funksjon tilgjengelig i spesifi kke
c-versjoner).
- med NAMUR-grensesnit for direkte montering på en-
keltløps (funksjon 3/2 NC) eller dobbeltløps (funksjon 5/2)
trykkluftsregulatorer. Ventilens funksjon kan konverteres
fra 3/2 NC til 5/2 ved å montere den medfølgende 13/2 NC
eller 5/2 grensesnittplaten på bunnen av ventilen (fi g. 13a,
13b, ref 1a og 1b). 551, Max. 1/4", maks. portdybde 11,5
mm. (
Ikke koble trykktilførselen til utblåsningsåpning 3.
Den “miljøvennlige” konstruksjonen er ikke tilpasset NO-
funksjon.
Ta kontakt med oss for funksjon tilgjengelig
i spesifi kke c-versjoner).
- Kobling av rør for de påkrevde funksjonene må skje i samsvar
med denne dokumentasjonen og portmerkene på produktet.
- For å forhindre blokkering av ventilfunksjonen må du sørge
for at det ikke kommer fremmedlegemer inn i kretsen. Bruk
av tetningstape eller tetningsmiddel bør begrenses til et
minimum.
- Disse ventilene er beregnet for bruk i forbindelse med ren
og tørr luft eller uvirksom (inert) gass. Anbefalt minimums-
ltrering: 50 mikron. Væskens duggpunkt må være minst
-10°C (18°F) lavere enn minstetemperaturen som væsken
kan bli eksponert for. Når det brukes oljeholdig luft, må
smøremiddelet være kompatibelt med elastomerene (elas-
tiske kunststoffer) som benyttes. Instrumentluft som er i
samsvar med ANSI/ISA-standard S7.3 (1975) overskrider
de nødvendige kravene og er derfor en akseptabel væske
for disse ventilene.
!
Alle utblåsningsporter på ventilene og pilotene må
være beskyttet med utblåsningsvern av rustfritt stål.
Disse utblåsningsvernene kobles til port 3 (3/2 NC)
eller port 3 - 5 /5/2). Når de brukes utendørs, eller oppbe-
vares i lange perioder og/eller når de eksponeres for
strenge miljøer (støv, væsker osv.) må det brukes utblås-
ningsvern. Påliteligheten til ventilene kan ikke garanteres
hvis det brukes et annet utblåsingsvern enn det som
følger med produktet.
- Tillatt temperaturområde: -40°C til +80°C (serie 551); -40°C
til +60°C (serie 553).
- Maksimalt arbeidstrykk:
- 2 til 10 bar
- 2 til 8 bar
(ISSC/PISC/PISCIS/CFSCIS/CFSDIS/CFVTIS)
BESKRIVELSE
ATEX 94/9/EC-versjoner: Se "Spesielle vilkår for sikker
bruk".
Versjoner som er isolert fra atmosfæren: De interne delene
av ventilen er isolert fra atmosfæren utenfor for å gi vern i
aggressive miljøer. Alle utblåsningsporter på spoleventilen
kan utstyres med rør, noe som gir bedre miljøvern og anbe-
fales spesielt i følsomme områder som renrom og til bruk i
farmasøytisk og matforedlende industri. Det er nødvendig å
koble rør eller armatur til utblåsningsportene for å beskytte
interne deler i spoleventilen hvis den brukes utendørs eller
under vanskelige forhold (støv, væsker osv.).
SPESIELLE VILKÅR FOR SIKKER BRUK
ATEX 94/9/EC-versjoner: Ventilen må jordes (se "Montasje")
Den maksimale væsketemperaturen må ikke være høyere
enn romtemperaturen.
Spoleventilen må oppbevares i sin opprinnelige innpakning
så lenge den ikke brukes. Vernedekslene må ikke fjernes fra
tilkoblingsportene og spoleoperatørene.
Lagringsbetingelser: Beskyttet mot vær; oppbevaringstem-
peratur: -40 °C til +70 °C; relativ luftfuktighet: 95 %
Etter lagring i lav temperatur må spoleventilene gradvis
bringes til driftstemperatur før de settes under trykk.
Spoleventilene er beregnet for bruk innenfor de tekniske
spesifi kasjoner som er angitt på navneplaten. Endringer av
produktene må kun gjøres etter rådføring med produsenten
eller hans representant. Disse spoleventilene er beregnet
til bruk i forbindelse med fi ltrert luft eller naturgass.
Ventilens største tillatte trykk må ikke overskrides = 10 bar
(eller 8 bar med en Piezotronic pilotventil til ATEX Ex ia). Du
må overholde minimumsverdien for styreventilen på 2 bar.
Installasjon og vedlikehold av ventilen må kun utføres av
kvalifi sert personale.
Standard IP65-klassifi serte luftdrevne versjoner eller
versjoner for bruk i eksplosive atmosfærer forårsaket av
gass, damp, dis eller støv i henhold til ATEX-direktiv 94/9/
EC. (Soneklassifi seringen for denne versjonen er angitt på
ATEX-merket, se E1).
Sikkerhetskode, serie 551: II 1 GD c T6 T85°C Ta -40°C til
+65°C.
Sikkerhetskode, serie 553: II 2 GD c T6 (T85°C) - T5 (T100°C).
EC typeundersøkelse sertifi katnr. (serie 551):
INERIS 03 ATEX 0219 X
Samsvar med de vesentlige helse- og sikkerhetskravene er
sikret gjennom samsvar med de europeiske standardene
EN 13463-1 og EN 13463-5.
Spole-luft-drevne versjoner utstyrt med spoleoperatører:
- IP65-forseglet eller
- sertifi sert for bruk i eksplosive atmosfærer i henhold til
ATEX-direktiv 94/9/EC
Versjoner med spoleoperatører med ASCO monterings-
pute,
- IP65-klassifi sert som standard, eller for bruk i eksplosive
atmosfærer II 3D IP65/IP67 eller ATEX Ex d, m, em, Ex ia
(serie 551: II 1G/2D Ex ia IIC IP65/IP67 eller serie 553:
II 2G/D Ex ia IIC IP65/IP67).
Versjoner med styreventiler med CNOMO E06.05.80
(størrelse 30) eller CNOMO E06.36.120N (størrelse 15)
monteringspute,
- IP 65-klassifi sert som standard, eller montering av styre-
ventiler for bruk i eksplosive atmosfærer i h.h.t. ATEX Ex
d eller EEx ia.
Advarsel (CNOMO-styreventiler): Soneklassifi seringen
(ATEX 1999/927EC) er i hovedsak defi nert av indikasjo-
nene på navneskiltet fi g. 10 og 20 (ref. E1 eller E2) på
ventilhuset. Sikkerhetskode i henhold til ATEX-direktiv
94/9/EC: II 1GD c T6 T85°C Ta -40°C til +65°C
EC typeundersøkelse sertifi katnr.: INERIS 03 ATEX 0219 X
Når dette produktet settes sammen med en styreventil i
henhold til ATEX 94/9/EC, må du regne ut fra den minst
fordelaktige kategorien, Maksimalt arbeidstrykk og
temperaturen. Samsvar med de vesentlige helse- og sikker-
hetskravene er sikret gjennom samsvar med de europeiske
standardene EN 13463-1 og EN 13463-5. Monteringsstillin-
gene for styreventiler som vist i fi gur 4/5/14/15/21/22/23/24
og de indikerte strammemomentene må etterfølges.
Når det gjelder spoleoperatører og styreventiler i henhold
til ATEX 49/9/EC, må man strengt holde seg til bruksan-
visningen gitt i de spesifi kke installasjonsinstruksene
som kommer sammen med produktet.
MONTERING
!
ATEX 94/9/EC-versjoner:rg for at alle metall- eller
ledende deler alltid er innbyrdes tilsluttet og jordet. Ventilhuset
er jordet med festeskruen (se F). Ventilene kan monteres i
en hvilken som helst stilling.
Versjoner med gjengede porter 1/4 (fi g 3a), 1/2 (fi g 3b):
Monter ventilen med to skruer (se 1) (følger ikke med).
Versioner med NAMUR-grensesnitt (fi g. 13a, 13b):
r spoleventilen monteres på styringen, må den innstilles
for den påkrevde funksjon:
- Velg det grensesnittet som korresponderer med den på-
krevde funksjon: 3/2 NC eller 5/2 (se 1a eller 1b).
- Påse at pakningen er riktig tilpasset (se 7).
- Monter grensesnittet under spoleventilen med de to medføl-
gende skruene (se 8). Påse at indikeringen for funksjonen
befi nner seg på retursiden (polariseringssporet).
- Sett inn de to O-ringene (se 9).
INSTALLASJONS- OG VEDLIKEHOLDSINSTRUKSER
3/2 NC
NO
Serie 551 magnetventiler, messinghus, eller serie 551-553, hus av rustfritt
stål, ¼“, ½" gjenger eller NAMUR-grensesnitt
5/2 - 5/3
- Om nødvendig, sett styrepinnen på styringen:
• På 3/2 NC-funksjonsplaten: Ø 5-hullet er ved A1.
• På 5/2-funksjonsplaten: Ø 5-hullet er ved A2.
TRYKKLUFTKOPLING (fi g. 3a, 3b, 13a OG 13b)
Avhengig av versjonen (3/2 NC eller 5/2) kan ett eller begge
utblåsningsvern av rustfritt stål brukes (se fi g. 2).
Tilkobling av versjon med luftstyring:
G 1/8 eller NPT 1/8 eller G 1/4 eller NPT 1/4.
Tilkobling av styreventilens utblåsninger
Utblåsingene kan samles inn i henhold til versjonen som
brukes.
Manuell overstyring
Avhengig av versjon, leveres produktene uten manuell
overstyring eller med manuell overstyring av impulsty-
pen for drift uten strøm. Den manuelle oversgtyringen er
angitt med symbolet(
) på fi g. 4, 5, 14, 15, 21 til 24 og ref.
10 på fi g. 3a, 3b, 13a, 13b.
Operatør av pulstypen eller vedlikeholdt (trykk/drei-type)
manuell overstyring angis med symbolet ( ) på fi g. 3a, 3b,
13a og 13b tillater bruk uten strøm.
!
Før bruk må den manuelle overstyringen være satt i
utkoblet stilling "0" for å forhindre risiko for personskade
eller skade på utstyret.
Tilpasning til ekstern pilottilførsel
(fi g.3a, 3b, 13a et 13b, ref. 6)
Generelle anbefalinger for tilkobling av trykkluft
Koble rør for de påkrevde funksjonene i samsvar med denne
dokumentasjonen og portmerkene på produktet.
rg for at det ikke kommer fremmedlegemer inn i systemet.
rene må støttes og justeres for å forhindre mekanisk
belastning på ventilen. Når du strammer må du ikke bruke
ventilen som brekkstang. Sett skrunøkler så nær tilkob-
lingspunktet som mulig. For å unngå skade på utstyret må
rkoblingene IKKE TREKKES TIL FOR STRAMT.
Versjoner med gjengede porter 1/4 (fi g 3a), 1/2 (fi g 3b):
Tilkopling av spoleventil:
Koble rørene til som anvist på merket:
- 3/2 NC-funksjon:
Trykkinntak gjennom port 1 (1/4” eller ½” gjenger). Tryk-
kutgang gjennom port 2.
Utblåsning gjennom port 3 (1/4” eller 1/2” gjenger).
- 5/2-funksjon:
Trykkinntak gjennom port 1. Trykkutgang gjennom port 2 og
4.
Utblåsning kanaliseres gjennom ventilen til port 3 og 5.
Versjon med NAMUR-grensesnitt (fi g. 13a,13b):
Tilkobling av spoleventilen:
Kople rørene som vist på merkelappen:
- 3/2 NC-funksjon:
Trykkinntak gjennom port 1 (1/4” eller ½” gjenger). Trykkutgang
gjennom port 2.(messinghus: 1/8; hus av rustfritt stål: 1/4" eller
1/2" gjenger)
Utslipp fra returstyringens fjærkamre i den enkeltvirkende
versjonen, er kanalisert gjennom ventilen til 1/8 " port 3. Det
anbefales å beskytte port 5 (dersom den ikke er i bruk) - til-
stoppe den ikke.
- 5/2-funksjon:
Trykkinntak gjennom port 1 (1/4” eller ½” gjenger). Tryk-
kutgang ved port 2 og 4.
Utslippene er kanalisert gjennom ventilen til portene 3
og 5 (messinghus: 1/8; hus av rustfritt stål: 1/4" eller 1/2"
gjenger).
Tilkobling av utblåsingsreduksjonsmuffe (hus av mes-
sing)
Serie 551 spoleventiler leveres som bestilt med eller uten
1/8” ublåsingsreduksjonsmuffer, suffi ks M (fi g. 13a).
Disse justerbare miniutblåsingsreduksjonsmuffene brukes
til å justere regulatorens driftshastighet. De kan også kobles
til (1/8 gjenger) for å samle utblåsingene.
Montasje / Justering (fi g. 3a)
Versjon 3/2 NC = 1 utblåsingsreduksjonsmuffe settes på
port 3
Versjon 5/2 = 2 utblåsingsreduksjonsmuffe settes på port
3 og 5
Sett skruen (4) på reduksjonsmuffen i hullet og skru den til
den stopper. Skru den deretter ut for å øke utblåsingsfl yten
(aldri mer enn to omdreininger, maks. yt oppnås ved
én omdreining).
Stram til låsemutteren (4a) med en 13 mm nøkkel.
Foreta en grovjustering før den settes under trykk og fi njuster
etterpå.
ELEKTRISK TILKOBLING
Versjon uten spolehoder med ASCO-grensesnitt:
Se ytterligere installasjonsinstrukser som følger med hvert spo-
lehode.
IP65-merket spoleoperatør (fi g. 3a, 3b og 13a, 13b): Sett
spolen på røret (kan roteres gjennom 360°) og deretter
den fjernbare ISO 4400/EN 175101-803A-konnektoren
(kabel dia 6-10 mm) som kan roteres 90° (3 pinner: 2 +
jord).
Versjon med CNMO monteringspute:
Se ytterligere monteringsinstruks som følger med hver styre-
ventil.
Generelle anbefalinger:
Elektriske koblinger må gjøres av kvalifi sert personell og i
henhold til gjeldende lokale standarder og forskrifter.
Forsiktig:
- r eventuelle inngrep må du slå av strømmen slik at
komponentene slås av.
- Avhengig av spenningen må elektriske komponenter være
jordet i henhold til lokale standarder og forskrifter.
De fl este ventiler er utstyrt med spoler beregnet på konti-
nuerlig drift. For å redusere risikoen for personskade må
man ikke berøre spoleoperatøren, som kan bli varm under
normale driftsforhold. Hvis ventilen er lett tilgjengelig, må
installatøren sette opp vern som forhindrer tilfeldig kontakt
med spoleoperatøren.
VEDLIKEHOLD
!
Før eventuelt vedlikeholdsarbeid eller før ventilen settes i
drift, skal den slås av, trykket skal tas ut og ventilen ventileres
for å redusere risikoen for skade på personer eller utstyr.
ATEX-versjoner: Alle prosedyrer anbefalt av Alle prosedyrer
som anbefales av direktiv 99/92/EC og tilknyttede standarder
må følges nøye.
Rengjøring
Vedlikehold av ventilene avhenger av driftsforholdene. De
må rengjøres regelmessig. Under service bør komponen-
tene kontrolleres for graden av slitasje. Komponentene må
rengjøres når man merker en nedgang i takten, selv om
trykket i styreventilen er korrekt, eller hvis det oppdages
uvanlig støy eller det oppstår lekkasje.
Støy
Støynivået avhenger av bruksområdet, mediet og typen
utstyr som brukes.yaktig fastsettelse av støynivået kan
bare gjøres av brukeren som har ventilen installert i sitt
system.
Forebyggende vedlikehold
- Bruk ventilen minst én gang i måneden for å kontrollere
funksjonaliteten.
-
Hvis det oppstår problemer under vedlikehold eller hvis du er
i tvil, vennligst ta kontakt med oss eller en av våre autoriserte
representanter.
Feilsøking
- Feil utgangstrykk: Kontroller trykket på ventilens tilførsels-
side. Det må tilsvare verdiene som fremgår av navneplaten.
Forsiktig: du må overholde minimumsverdien for styreventilen på
2 bar.
For å unngå skade på personer eller utstyr må du kontrol-
lere at ventilen fungerer som den skal før du setter den
tilbake i bruk.
Reservedeler
Spoler er tilgjengelige som reservedeler.
Hvis nødvendig, skifter du ut hele ventilen.
INSTALLASJONS- OG VEDLIKEHOLDSINSTRUKSER
3/2 NC
NO
Serie 551 magnetventiler, messinghus, eller serie 551-553, hus av rustfritt
stål, ¼“, ½" gjenger eller NAMUR-grensesnitt
5/2 - 5/3
17
16
3834901
3834901
BESKRIVNING AV GODKÄNNANDET
Utföranden som berörs av godkännandet (fi g. 1 och 11):
Ventilkropp av mässing (serie 551) eller rostfritt stål (serie
551, 553), monostabil (fjäderretur) eller bistabil, 3/2 NC-
funktion (normalt stängd) eller 5/2, version isolerad från
den omgivande atmosfären. Utföranden utan manuell
företrädesstyrning eller med manuell företrädesstyrning
av impulstyp:
- med gängade portar 1/4 (551) eller 1/2 (553) - 551, med ¼”
gjenget kobling, maks. portdybde 11,5 mm. (Anslut inte
tryckkopplingen till utgångsport 3. Den “miljöskyddande”
konstruktionen är inte anpassad för en “distribuerande”
funktion eller använd NO-funktionen. Kontakta oss för
mer om vilka funktioner som är tillgängliga för specifi ka
versioner).
- med NAMUR-koppling för direkt montering till enkelverkande
(funktion 3/2 NC) eller dubbelverkande (funktion 5/2) pneu-
matiska ställdon. Ventilens funktion kan konverteras från 3/2
NC till 5/2 genom att montera medlevererad 13/2 NC eller
5/2 kopplingsplatta underst på ventilen (fi g. 13a, 13b, ref. 1a
och 1b). 551, 1/4”, maks. portdybde 11,5 mm. (
Anslut inte
tryckkopplingen till utgångsport 3. Den “miljöskyddande”
konstruktionen är inte anpassad för NO-funktion.
Kontakta
oss för mer om vilka funktioner som är tillgängliga för
specifi ka versioner).
- Anslut ledningarna för de önskade funktionerna enligt in-
struktionerna i den här dokumentationen och portmärkningen
på produkten.
- Se till att inga främmande material som kan blockera
ventilfunktionen kommer in i systemet. Försök att hålla an-
vändningen av tätningstejp eller andra tätningsmaterial ett
minimum.
- De här ventilerna är avsedda för användning med en ren och
torr luft eller ädelgas. Rekommenderad minimum fi ltrering:
50 mikron. Daggpunkten för vätskan som används måste
vara minst -10°C (18°F) under den minimumtemperatur
som vätskan får utsättas för. Vid användning av smord luft
måste smörjmedlet vara förenligt med de elaster som an-
vänds. Pneumatisk luft i överensstämmelse med ANSI/ISA
standard S7.3 (1975) överskrider nödvändiga krav och är
därför en godkänd vätska för dessa ventiler.
!
Alla utgångsportar från ventiler och styrventiler
måste skyddas med de rostfria utgångsskydden.
Koppla utblåsskydden på port 3 (3/2 NC) eller port 3
- 5 (5/2). Utblåsskydd skall användas vid tillämpningar
utomhus eller vid förvaring under längre tid, och/eller
när de utsätts för svåra omgivningar (damm, vätskor etc.).
Ventilens tillförlitlighet kan inte garanteras när ett annat
än det medlevererade utblåsskyddet används.
- Tillåtet temperaturområde: -40°C till +80°C (serie 551); -40°C
till +60°C (serie 553).
- Maximum arbetstryck:
- 2 - 10 bar
- 2 - 8 bar
(ISSC/PISC/PISCIS/CFSCIS/CFSDIS/CFVTIS)
BESKRIVNING
ATEX 94/9/EC-versioner: Se "Särskilda förhållanden för säker
användning".
Versioner som är isolerade från atmosfären: Ventilens in-
vändiga delar är isolerade från atomsfären utanför och skyddas
därför vid användning i aggressiva miljöer. Alla utgångsportar
på rundslidsventilen kan förses med rörförbindning, vilket
ger bättre miljöskydd och rekommenderas särskilt i känsliga
omgivningar såsom i "rena rum" och för tillämpning inom lä-
kemedels- och livsmedelsindustrin. Vid användning utomhus
eller i krävande miljöer (damm, vätskor o dyl) är nödvändigt
att ansluta ledningar eller fi xturer till utgångsportarna för att
skydda rundslidsventilens invändiga delar.
SÄRSKILDA FÖRHÅLLANDEN FÖR SÄKER ANVÄNDNING
ATEX 94/9/EC-versioner: Ventilen ska anslutas till jord (se
"Montera").
Den maximalt tillåtna vätsketemperaturen får inte överstiga
omgivningstemperaturen.
Rundslidsventilen ska förvaras i originalförpackningen så
länge den inte används. Låt skydden på anslutningsportarna
och solenoidoperatörerna sitta kvar.
Förvaringsförhållanden: inomhus; förvaringstemperatur: -40
C - +70°C; relativ fuktighet: 95 %
Efter kall förvaring måste rundslidsventilen gradvis vär-
mas upp till arbetstemperatur innan den sätts under tryck.
Rundslidsventilerna är avsedda för att användas i enlighet
med de tekniska egenskaper som står angivna på namn-
plattan. Modifi kationer av produkterna är enbart tillåtet med
medgivande från tillverkaren eller auktoriserad representant.
De här solenoidrundslidsventilerna är konstruerade för
att användas med fi ltrerad luft eller neutral gas. Ventilens
maximalt tillåtna tryck får inte överskridas = 10 bar (eller 8 bar
med en Piezotronic pilotventil med ATEX Ex ia). Observera
minimum pilottryck på 2 bar. Installation och underhåll av
ventilen får enbart utföras av behörig personal.
Standard IP65-märkta luftstyrda versioner eller versioner
för användning i explosiva atmosfärer som uppstår genom
gaser, ånga, dimma eller damm enligt ATEX-direktiv 94/9/
EC. (Zonklassifi ceringen för den här versionen anges på
ATEX-etiketten, ref E1).
Skyddskod, serie 551: II 1 GD c T6 T85°C Ta -40°C till +65°C.
Säkerhetskod, serie 553: II 2 GD c T6 (T85°C) - T5 (T100°C).
EC-typ provningscertifi kat nr. (Serie 551):
INERIS 03 ATEX 0219 X
Uppfyllande av Grundläggande Hälso- och Säkerhetskrav
försäkras genom överensstämmelse med Europeiska Normer
EN 13463-1 och EN 13463-5.
luftstyrda solenoidversioner med solenoidoperatörer:
- IP65 tätad eller
- certifi erad för användning i explosiva atmosfärer i enlighet
med ATEX direktiv 94/9/EC
Versioner med solenoidoperatörer med ASCO monte-
ringsplatta,
- IP65-märkt som standard eller för användning i explosiva
atmosfärer II 3D IP65/IP67 eller ATEX Ex d, m, em, Ex ia
(Serie 551: II 1G/2D Ex ia IIC IP65/IP67 eller serie 553: II
2G/D Ex ia IIC IP65/IP67).
Versioner med piloter med CNOMO E06.05.80 (storlek 30)
eller CNOMO E06.36.120N (storlek 15) monteringsplatta,
- IP 65-märkt som standard eller monterad med piloter för
användning i explosiva atmosfärer i enlighet med ATEX Ex
d eller EEx ia.
Varsamhet (CNOMO-piloter): Zonklassifi ceringen (ATEX
1999/927EC) defi nieras huvudsakligen av vad som
anges på typskylten fi g. 10 och 20 (ref. E1 eller E2) på
ventilkroppen. Skyddskod enligt ATEX-direktivet 94/9/
EC: II 1 GD c T6 T85°C Ta -40°C till +65°C
Certifi katnr för EC typundersökning: INERIS 03 ATEX 0219 X
Ta hänsyn till den minst gynnsamma kategorin, maximum
arbetstryck och temperaturen vid montering av den här
produkten till en pilot till ATEX 94/9/EC. Uppfyllande av
Grundläggande Hälso- och Säkerhetskrav försäkras genom
överensstämmelse med Europeiska Normer EN 13463-1
och EN 13463-5. Styrventilernas monteringsposition såsom
visas i fi gurerna 4/5/14/15/21/22/23/24 och de angivna åt-
dragningsmomenten måste iakttas.
För solenoidoperatörer och piloter till ATEX 49/9/EC, ska
användarinstruktionerna i motsvarande Installationsin-
struktioner som medföljer produkten, strikt följas.
MONTERING
!
ATEX 94/9/EC-versioner: Se till att alla metalldelar eller
ledande delar alltid är sammankopplade och jordade. Ven-
tilstommen är jordad via fästskruven (ref F).
Ventilerna kan monteras i valfri position.
Versioner med gängade portar 1/4 (fi g 3a), 1/2 (fi g 3b):
Montera ventilen med två skruvar (ref 1) (ingår ej).
Versioner med NAMUR-koppling (fi g. 13a, 13b):
Innan rundslidsventilen monteras på operatören måste den
först ställas in på önskad funktion:
- Välj den anslutningstyp som överensstämmer med önskad
INSTALLATIONS- OCH UNDERHÅLLSINSTRUKTIONER
3/2 NC
SE
Serie 551 magnetventiler, mässingskropp, eller serie 551-553,
rostfri stålkropp, ¼", ½" gänga eller NAMUR-koppling
5/2 - 5/3
funktion: 3/2 NC eller 5/2 (rep.1a eller 1b).
- Se till att packningen monteras korrekt (rep.7).
- Montera anslutningen under rundslidsventilen med de två
medlevererade skruvarna (rep.8). Se till att funktionsindi-
keringen placeras på retursidan (polariseringsöppning).
- Placera de två O-ringarna (rep.9).
- Om nödvändigt, montera låspinnen på operatören:
• På 3/2 NC funktionsplatta: Ø 5 dia. är hål A1.
• På 5/2 funktionsplatta: Ø 5 dia. är hål A2.
PNEUMATISK ANSLUTNING (fi g. 3a, 3b, 13a och 13b):
Beroende3 på versionen (3/2 NC eller 5/2) kan en eller båda
utgångsskydden av rostfritt stål användas (se fi g. 2).
Ansluta pneumatisk pilotutförande:
G 1/8 eller NPT 1/8 eller G 1/4 eller NPT 1/4.
Ansluta pilotutblås
Utblåsluften kan hanteras enligt den version som används.
Manuell företrädesstyrning
Beroende på utförandet, levereras produkten utan manuell
företrädesstyrning eller med manuell företrädesstyrning
av impulstyp för strömlös operation: Det manuella nödreglaget
anges med symbolen ( ) i fi g. 4, 5, 14, 15, 21 till 24, och ref.
10 i fi g. 3a, 3b, 13a, 13b.
Det manuella nödreglaget av impulstyp eller bibehållen typ
(tryck/vrid), angivet med symbolen ( )i fi g. 3a, 3b, 13a och
13b möjliggör körning utan kraft.
!
Se till att den manuella företrädesstyrningen står
i tillbakaläget "0" för att förebygga risk för person och
materialskada.
Anpassning till extern styrmatning
(fi g. 3a, 3b, 13a och 13b, ref. 6)
Allmänna rekommendationer för pneumatiska anslut-
ningar
Anslut ledningarna för den önskade funktionen enligt instruk-
tionerna i den här dokumentationen och portmärkningen
på produkten.
Se till att inga främmande material kommer in i systemet.
För att förebygga mekanisk belastning på ventilen är det
viktigt att ledningarna har tillräckligt med stöd och är riktade
korrekt. Använd inte själva ventilen för åtdragningen, placera
momentnyckeln så nära anslutningspunkten som möjligt.
Var rädd om verktygen, DRA INTE ÅT kopplingarna FÖR
HÅRT.
Versioner med gängade portar 1/4 (fi g 3a), 1/2 (fi g 3b):
Ansluta rundslidsventilen:
Anslut ledningarna enligt etiketten:
- 3/2 NC-funktion:
Tryckingång vid port 1 (1/4” eller 1/2” gänga). Tryckutgång
vid port 2.
Utgång vid port 3 (1/4” eller 1/2” gänga).
- 5/2-funktion:
Tryckintag vid port 1. Tryckuttag vid port 2 och 4.
Utblåsningen kanaliseras via ventilerna till port 3 och 5.
Utförande med NAMUR-koppling (fi g 13a, 13b):
Ansluta rundslidsventilen:
Anslut ledningarna enligt etiketten:
- 3/2 NC-funktion:
Tryckingång vid port 1 (1/4” eller 1/2” gänga). Tryckutgång
vid port 2.
Utblås vid port 3 (mässingskropp: 1/8 ; rostfri stålkropp:
1/4" eller 1/2"
Utblåset från returstyrda fjäderkammare i den enkelver-
kande
versionen kanaliseras via ventil port 3. Vi rekom-
menderar att skydda port 5 (om oanvänd) - plugga inte
till det.
- 5/2-funktion:
Tryckingång vid port 1 (1/4” eller 1/2” gänga).
Utblåsningen kanaliseras via ventilerna till port 3 och
5 (mässingskropp: 1/8 ; rostfri stålkropp: 1/4" eller 1/2"
gänga).
Koppla utblåsreducerare (mässingkropp):
Serie 551 spolventiler levereras enligt order med eller utan
miniatyr 1/8” utgångsreuktorer, suffi x M (fi g. 13a).
De justerande mini utblåsreducerarna används för att an-
passa ställdonets arbetshastighet. De kan också kopplas
(1/8 gänga) för att hantera utblåsluften.
Montering / Justering (fi g. 3a):
Version 3/2 NC = 1 utblåsreducerare som kopplas till port 3
Version 5/2 NC = 2 utblåsreducerare som kopplas till port 3
och 5
Sätt i skruven (4) på reduceraren i hålet och skruva fast den
helt; öppna sedan skruven för att öka utblåsfl ödet (dock
aldrig mer än två slag, max. öde erhålls vid ett varv).
Spänn fast låsmuttern (4a) med en 13 mm nyckel.
Grovinställ innan trycket slås på och fi njustera när trycket
är på.
ELEKTRISK ANSLUTNING
Utförande med magnethuvud med ASCO-koppling:
Läs installationsinstruktionerna som levereras med res-
pektive magnethuvud.
IP65-klass megnhetreglage (fi g. 3a, 3b och 13a, 13b):
Montera spolen på röret (vridbar 360°) och sedan den
löstagbara ISO 4400/EN 175101-803A kontakten (kabel-
diam. 6-10 mm) vridbar 90° (3 stift: 2 + jord).
Utförande med CNOMO plattmontage:
Läs installationsinstruktionerna som levereras med res-
pektive pilotventil.
Allmänna rekommendationer:
Elektriska anslutningar ska utföras av behörig tekniker och
i enlighet med lokala normer och regler.
Varsamhet:
- Innan något utförs ska all strömförsörjning till komponen-
terna kopplas bort.
- Beroende på strömstyrka ska elektriska komponenter
jordas enligt lokala normer och regler.
De fl esta ventiler har spolar som konstruerats för kon-
tinuerlig drift. För att förebygga personskador, vidrör
inte solenoidoperatören som kan bli mycket varm under
normala driftförhållanden. Om solenoidventilen är lätt att
komma åt ska installatören förse med lämpligt skydd för
att förekomma oavsiktlig kontakt.
UNDERHÅLL
!
För att förebygga maskin- och personskada ska
strömförsörjning och tryck ska vara bortkopplat och
ventilen luftas innan underhåll eller driftsättning utförs.
ATEX-versioner: Följ strängt alla procedurer rekommen-
derade i Direktivet 99/92/EC och tillhörande normer.
Rengöring
Underhållet av ventilerna är beroende på driftförhållandena.
De ska rengöras med regelbundna intervaller. Vid service
ska komponenterna kontrolleras på överdrivet slitage. Det
är dags att rengöra komponenterna när arbetscyklerna går
långsammare trots att pilottrycket är rätt eller när ovanliga
ljud eller läckage uppstår.
Buller
Bullernivån är beroende på tillämpningen, medium och
typen av utrustning som används. En korrekt mätning av
bullernivån kan enbart utföras hos användaren där ventilen
installerats i ett system.
Förebyggande underhåll
- Driftsätt ventilen minst en gång i månaden för att kontrol-
lera att den fungerar som den ska.
- Om problem uppstår vid underhåll eller vid tvivel, var god
kontakta oss eller ett av våra auktoriserade ombud.
Problemlösning
- Inkorrekt utgångstryck: Kontrollera trycket på ventilens
matarsida som ska korrespondera med värdena på
namnplattan.
Varsamhet: observera att minimalt pilottryck är 2 bar.
För att förebygga person- och maskinskada, kontrollera
att ventilen fungerar korrekt innan den sätts i drift igen.
Reservdelar
Spolar kan beställas som reservdel.
Om nödvändigt, byt ut hela ventilen.
INSTALLATIONS- OCH UNDERHÅLLSINSTRUKTIONER
3/2 NC
SE
Serie 551 magnetventiler, mässingskropp, eller serie 551-553,
rostfri stålkropp, ¼", ½" gänga eller NAMUR-koppling
5/2 - 5/3
19
18
3834901
3834901
HYVÄKSYNTÄTIEDOT
Hyväksyntä koskee seuraavia versioita (kuvat 1 ja 11):
Messinkirunko (sarja 551) tai ruostumaton teräsrunko
(sarjat 551, 553), yksiasentoinen (jousipalaute) tai kaksi-
asentoinen, 3/2 NC -toiminen (yleensä kiinni) tai 5/2-toi-
minen versio, joka on eristetty ympäröivästä ilmasta.
Versioita, joissa ei ole käsitoimista ohitusta tai joissa on
impulssityyppinen käsitoiminen ohitus ja:
- 1/4”:n (551) tai 1/2”:n (553) kierreaukot - 551, jossa ¼”
kierteellinen liitäntä, aukon maks. syvyys 11,5 mm. (Älä
yhdistä paineen syöttöä poistoaukko 3:een. ”Ympäristö-
suojattua” rakennetta ei ole sovitettu ”jakelu”-toimintoon
tai käytä EI-toimintona. Kysy meiltä erikoisversioissa
käytettävissä olevista toiminnoista).
- NAMUR-liitäntä suoraan asennukseen yksitoimiseen (3/2
NC -toiminto) tai kaksitoimiseen (5/2-toiminto) painetoi-
milaitteeseen. Venttiilin toiminta voidaan muuttaa 3/2 NC
-toiminnosta 5/2-toimintoon asentamalla mukana toimitettu
3/2 NC- tai 5/2-liitäntälevy venttiilin pohjaan (kuvat 13a, 13b,
kohta 1a ja 1b). 551, 1/4”, maks. syvyys 11,5 mm. (Älä
yhdistä paineen syöttöä poistoaukko 3:een. ”Ympäris-
tösuojattua” rakennetta ei ole sovitettu EI-toimintoon.
Kysy meiltä erikoisversioissa käytettävissä olevista
toiminnoista).
- Liitä tarvittavien toimintojen putket näiden asiakirjojen ja
tuotteen aukkomerkintöjen mukaisesti.
- Varmista, ettei mitään vierasta ainesta pääse mukaan kier-
toon, jottei venttiilin toiminta esty. Käytä mahdollisimman
vähän eristysteippiä tai -aineita.
- Nämä venttiilit on suunniteltu käytettäviksi puhtaan ja kuivan
ilman tai reagoimattomien kaasujen kanssa. Suositeltava
vähimmäissuodatus on 50 mikrometriä. Käytettävän väli-
aineen kastepisteen on oltava vähintään - 10 °C (18 °F)
alle pienimmän mahdollisen lämpötilan, johon väliaine voi
joutua. Käytettäessä voideltua ilmaa voiteluaineen on oltava
yhteensopiva käytettyjen elastomeerien kanssa. ANSI/ISA
S7.3 (1975) -standardin vaatimukset täyttävä paineilma ylit-
tää näiden venttiilien vaatimukset, ja se on siis hyväksyttävä
väliaine näihin venttiileihin.
!
Kaikki venttiilien poistoaukot ja ohjauslaitteet on
suojattavaruostumattomasta teräksestä valmistetuil-
la poistosuojuksilla. Kiinnitä poistoaukon suojat
aukkoon 3 (3/2 NC) tai aukkoihin 3-5 (5/2). Ulkokäytössä
tai varastoitaessa pitkiksi ajoiksi ja/tai joutuessaan alt-
tiiksi ankarille olosuhteille (pöly, nesteet jne.), on käytet-
tävä poistoaukon suojia.
Venttiilin luotettavuutta ei voida taata, jos käytetään muuta
kuin toimitettua poistoaukon suojaa.
- Hyväksyttävä käyttölämpötila-alue: -40 °C...+80 °C (sarja 551);
-40 °C...+60 °C (sarja 553).
- Suurin käyttöpaine:
- 2-10 baaria
-
2-8 bar baaria (ISSC/PISC/PISCIS/CFSCIS/CFSDIS/CFVTIS)
KUVAUS
ATEX 94/9/EY -standardin mukaiset versiot: Katso kohta
Turvalliset käyttöolosuhteet.
Ilmakehästä eristetyt versiot: Venttiilin sisäiset osat on eris-
tetty ilmakehästä suojaksi syövyttävältä ympäristöltä. Kaikki
karaventtiilin poistoaukot voidaan putkittaa, jotta ne suojaavat
ympäristöä paremmin. Putkitusta suositellaan etenkin herkillä
alueilla kuten puhdastiloissa ja lääke- ja elintarviketeollisuu-
dessa. Karaventtiilin sisäosien suojaamiseksi poistoaukkoihin
on asennettava putket tai liittimet, jos karaventtiiliä käytetään
ulkotiloissa tai ankarissa olosuhteissa (jotka sisältävät esim.
pölyä tai nestettä).
TURVALLISET KÄYTTÖOLOSUHTEET
ATEX 94/9/EC -standardin mukaiset versiot: Venttiili pitää
liittää maahan (katso osiota "Asentaminen").
Väliaineen maksimilämpötila ei saa ylittää ympäristön läm-
pötilaa.
Karaventtiiliä on säilytettävä alkuperäisessä pakkauksessaan,
jos sitä ei käytetä. Liitäntäaukkojen ja magneettitoimilaitteiden
suojuksia ei saa poistaa.
Säilytysolosuhteet: Suojattava säältä. Säilytyslämpötila:
-40...+70 °C. Suhteellinen kosteus: 95 %
Kun karaventtiilejä on säilytetty alhaisessa lämpötilassa,
ne on vähitellen saatettava käyttölämpötilaan ennen
paineistamista.
Karaventtiilit on tarkoitettu käytettäväksi tyyppikilvessä mää-
riteltyjen teknisten ominaisuuksien mukaisesti. Tuotteisiin saa
tehdä muutoksia vain valmistajan tai valmistajan edustajan
luvalla. Nämä magneettitoimiset karaventtiilit on suunni-
teltu käytettäväksi suodatetun ilman tai neutraalin kaa-
sun kanssa. Älä yritä venttiilin suurinta sallittua painetta =
10 baaria (tai Piezotronic-ohjausventtiilillä 8 baaria ATEX Ex
ia -standardin mukaisesti). Huomioi, että minimiohjauspaine
on 2 baaria. Venttiilin asennuksen ja huollon saavat suorittaa
vain valtuutetut henkilöt.
Standardinmukaiset IP65-luokan ilmatoimiset versiot tai
versiot, jotka on suunniteltu käytettäväksi kaasua, höyryä,
sumua tai pölyä sisältävissä räjähdysvaarallisissa tiloissa
ATEX 94/9/EY -direktiivin mukaisesti. (Tämän version alue-
luokitus ilmoitetaan ATEX-merkinnän kohdassa liite E1).
Turvakoodi, sarja 551: II 1GD c T6 T85 °C Ta –40 °C...+65 °C
Turvakoodi, sarja 553: II 2 GD c T6 (T85°C) - T5 (T100°C).
EY-tyyppitarkastustodistus nro (sarja 551):
INERIS 03 ATEX 0219 X
Yhteensopivuus terveys- ja turvavaatimusten kanssa on
varmistettu noudattamalla EY-standardeja EN 13463-1 ja
EN 13463-5.
Magneetti-ilmatoimiset versiot, joihin on asennettu mag-
neettitoimilaitteet:
- IP65-koteloitu tai
- sertifi oitu käytettäväksi räjähdysvaarallisissa ympäristöissä
ATEX 94/9/EY -direktiivin mukaisesti
Versiot, joissa on magneettitoimilaitteet ja ASCO-kiin-
nitysalusta
- tai IP65-kotelointi vakiona tai jotka on tarkoitettu käytet-
täväksi räjähdysvaarallisissa ympäristöissä standardien
II 3D IP65/IP67 tai ATEX Ex d, m, em, Ex ia mukaisesti
(Sarja 551: II 1G/2D Ex ia IIC IP65/IP67 tai sarja 553: II
2G/D Ex ia IIC IP65/IP67).
Versiot, joissa on ohjauslaitteet ja CNOMO E06.05.80
(koko 30)- tai CNOMO E06.36.120N (koko 15) -kiinnitys-
alusta
- tai IP65-kotelointi vakiona tai joissa ohjauslaitteet asenne-
taan venttiilin käyttämiseksi räjähdysvaarallisissa ympäris-
töissä ATEX Ex d- tai Ex ia -direktiivin mukaisesti.
Alueluokitus (ATEX 1999/927EY) määritetään ensisijaisesti
venttiilin rungossa olevan tyyppikilven merkinnällä kuvat
10 ja 20 (kohta E1 tai E2). ATEX 94/9/EY -direktiivin mukai-
nen turvakoodi: II 1 GD c T6 T85 °C Ta -40 °C...+65 °C
EY-tyyppitarkastustodistus nro:
INERIS 03 ATEX 0219 X.
Kun tämä tuote asennetaan ohjauslaitteeseen ATEX 94/9/
EY -direktiivin mukaisesti, epäedullisin luokka ja lämpötila,
suurin käyttöpaine on otettava huomioon. Yhteensopivuus
terveys- ja turvavaatimusten kanssa on varmistettu noudat-
tamalla EY-standardeja EN 13463-1 ja EN 13463-5. Ohjaus-
laitteiden asennuspaikkoja kuvissa 4/5/14/15/21/22/23/24 ja
ilmoitettuja kiristysmomentteja tulee noudattaa.
ATEX 94/9/EY -direktiivin mukaisten magneettitoimilait-
teiden ja ohjauslaitteiden mukana toimitettuja asennus-
ohjeita on ehdottomasti noudatettava.
ASENTAMINEN
!
ATEX 94/9/EY -standardin mukaiset versiot: Tarkista,
että kaikki metalliset tai johtavat osat on aina kytketty toisiinsa
ja maahan. Venttiilin runko kytketään maahan kiinnitysruuvilla
(kohta F).
Venttiilit voidaan asentaa mihin asentoon tahansa.
Kierreaukkoversiot 1/4 (kuva 3a), 1/2 (kuva 3b):
Asenna venttiili kahdella ruuvilla (kohta 1) (eivät sisälly
toimitukseen).
NAMUR-liitäntäversiot (kuvat 13a, 13b):
Ennen kuin asennat karaventtiilin ohjauslaitteelle, aseta se
oikeaan toimintoon:
- Valitse liitäntä, joka vastaa oikeaa toimintoa: 3/2 NC tai 5/2
(kohta 1a tai 1b).
- Varmista, että tiiviste on kunnolla paikallaan (kohta 7).
- Asenna liitäntä karaventtiilin alle kahdella mukana toimitetulla
ASENNUS- JA HUOLTO-OHJEET
3/2 NC
FI
Sarjan 551 solenoidiventtiilit, joissa messinkirunko, tai sarjojen 551–553 venttii-
lit, joissa ruostumaton teräsrunko, ¼”:n tai ½”:n kierteet tai NAMUR-liitäntä
5/2 - 5/3
ruuvilla (kohta 8). Varmista, että toimintoa kuvaava merkki
on takana (avainhahto).
- Aseta kaksi O-rengasta paikoilleen (kohta 9).
- Aseta johtotappi ohjauslaitteeseen tarvittaessa:
• 3/2 NC -toimintolevy: Ø 5 halk. aukko on kohdassa A1.
• 5/2 -toimintolevy: Ø 5 halk. aukko on kohdassa A2.
PAINELIITÄNTÄ (kuvat 3a, 3b, 13a ja 13b)
Versiosta riippuen (3/2 NC tai 5/2) voit käyttää yhtä tai kahta
ruostumattomasta teräksestä valmistettua poistoaukon suojaa
(katso kuva 2).
Paineohjauslaiteversion liittäminen:
G 1/8 tai NPT 1/8 tai G 1/4 tai NPT 1/4.
Ohjauslaitteiden poistoaukkojen liittäminen
Versiosta riippuen poistot voi kerätä yhteen.
Käsitoiminen ohittaminen
Riippuen versiosta, tuotteissa ei ole käsitoimista ohitusta
tai niissä on impulssityyppinen käsitoiminen ohitus, joilla
voit käyttää venttiiliä myös silloin, kun se ei ole jännitteellinen.
Käsitoimisen ohituksen merkkinä on symboli (
)kuvissa
4, 5, 14, 15 ja 21–24 ja kohdassa 10 kuvissa 3a, 3b, 13a,
13b.
Impulssityyppistä tai pitotyyppistä (painettava/käännettävä
tyyppi) käsitoimista ohitusta, jonka merkkinä on symboli (
), kuvissa 3a, 3b, 13a ja 13b, voidaan käyttää myös ilman
sähköä.
!
Ennen kuin otat laitteen käyttöön, varmista että
käsitoiminen ohitus on sammutettu ja "0"-asennossa.
Näin vältät henkilövahingot ja laitteiston vaurioitumisen.
Sovellus ulkoisen ohjauslaitteen syöttöön (kuvat 3a,
3b, 13a ja 13b, kohta 6)
Paineliitäntään liittyviä yleisiä suosituksia
Liitä tarvittavien toimintojen putket näiden asiakirjojen ja
tuotteen aukkomerkintöjen mukaisesti.
Varmista, että järjestelmään ei pääse vierasta ainesta.
Tue ja kohdista putket oikein, jotta venttiiliin ei kohdistu
mekaanista rasitusta. Älä käytä venttiiliä kiristyksen aikana
vipuna, vaan aseta vääntöavaimet mahdollisimman lähelle
liitoskohtaa. Laitevaurion välttämiseksi ÄLÄ KIRISTÄ PUT-
KILIITOKSIA LIIKAA.
Kierreaukkoversiot 1/4 (kuva 3a), 1/2 (kuva 3b):
Karaventtiilin liittäminen:
Liitä putket merkinnän mukaisesti:
- 3/2 NC -toiminto:
Painetulo aukossa 1 (1/4”:n tai 1/2”:n kierre). Painelähtö
aukkoon 2.
Poisto aukossa 3 (1/4”:n tai 1/2”:n kierre).
- 5/2-toiminto:
Painetulo aukkoon 1. Painelähtö aukkoihin 2 ja 4.
Poistot kanavoidaan venttiilin kautta aukkoihin 3 ja 5.
NAMUR-liitäntäversiot (kuva 13a, 13b):
Karaventtiilin liittäminen:
Liitä putket merkinnän mukaisesti:
- 3/2 NC -toiminto:
Painetulo aukossa 1 (1/4”:n tai 1/2”:n kierre). Painelähtö
aukkoon 2.
Poisto aukkoon 3 (messinkirunko: 1/8, ruostumaton
teräsrunko: 1/4”:n tai 1/2”:n kierre). Yksitoimisten versi-
oiden paluuohjaimen jousikammioiden poisto johdetaan
venttiilin läpi 1/8 tuuman 3-aukkoon. Suojaa 5-aukko (jos
se ei ole käytössä) - älä tulppaa sitä.
- 5/2-toiminto:
Painetulo aukossa 1 (1/4”:n tai 1/2”:n kierre).
Poistot kanavoidaan venttiilin kautta aukkoihin 3 ja 5
(messinkirunko: 1/8, ruostumaton teräsrunko: 1/4”:n tai
1/2”:n kierre).
Paineenalennusventtiilin kytkentä (messinkirunko):
Sarjan 551 karaventtiilit toimitetaan tilauksen mukaan pie-
nikokoisilla 1/8”:n poiston alennusventtiileillä varustettuina
tai ilman niitä, liite M (kuva 13a).
Näillä säädettävillä, pienillä paineenalennusventtiileillä
voidaan säätää laitteen käyttönopeutta. Ne voidaan myös
liittää (1/8 kierteellä) keräämään poistot.
Asentaminen/säätäminen (kuva 3a)
Versio 3/2 NC = asenna 1 paineenalennusventtiili aukkoon 3
Version 5/2 = asenna 2 paineenalennusventtiiliä aukkoihin
3 ja 5
Kiinnitä ruuvi (4) paineenalennusventtiilin reikään ja kierrä
sitä, kunnes se pysähtyy. Kierrä sitä sitten ulospäin lisätäk-
sesi poistovirtausta. (Aina korkeintaan kaksi kierrosta,
maksimivirtaus yhdellä kierroksella).
Kiristä lukkomutteri (4a) 13 mm:n ruuviavaimella.
Tee likimääräiset säädöt ennen paineistusta ja hienosäätö
paineistuksen jälkeen.
SÄHKÖLIITÄNTÄ
Versiot, joissa on magneettitoimiset päät ja ASCO-
liitäntä: Katso jokaisen magneettitoimisen pään mukana
toimitetut erilliset asennusohjeet.
IP65:n mukainen magneettitoimilaite (kuvat 3a, 3b, 13a
ja 13b): Asenna kela putkeen (360° kierrettävä) ja sen
jälkeen irrotettava ISO 4400/EN 175101-803A -liitin
(kaapelin halk. 6–10 mm) 90°:n askelin kierrettävä
(3 pinniä: 2 + maa).
Versiot, joissa CNOMO-kiinnitysalusta: Katso jokaisen
ohjausventtiilin mukana toimitetut erilliset asennusohjeet.
Yleiset suositukset:
Sähköliitännät saa tehdä vain valtuutetut henkilöt sovellet-
tavien paikallisten standardien ja säännösten mukaisesti.
Tärkeää:
- Katkaise osien virransyöttö ennen asennuksen aloitta-
mista.
- Sen mukaan mikä on jännite, sähköliitännät on maadoi-
tettava paikallisten standardien ja asetusten mukaisesti.
Useimmissa venttiileissä on jatkuvaa toimintaa varten
suunnitellut kelat. Henkilövahingon ehkäisemiseksi älä
kosketa magneettitoimilaitetta, joka voi kuumentua nor-
maaleissa käyttöolosuhteissa. Jos venttiiliin on helppo
päästä käsiksi, asentajan on järjestettävä riittävä suojaus
magneettitoimilaitteen tahattoman kosketuksen estämi-
seksi.
HUOLTO
!
Ennen venttiilin huoltamista tai käyttöönottoa kat-
kaise virta, poista venttiilistä paine ja tuuleta venttiili
henkilövahingon ja laitevaurion estämiseksi.
ATEX-versiot: Noudata huollon aikana tarkoin kaikkia
standardissa 99/92/EY suositeltuja ja siihen liittyvien
standardien mukaisia toimenpiteitä.
Puhdistus
Venttiilien huolto määräytyy käyttöolosuhteiden mukaan.
Venttiilit on puhdistettava säännöllisin väliajoin. Huollon
aikana on tarkistettava, ovatko osat kuluneet liikaa. Osat
on puhdistettava, kun kierto silmin nähden hidastuu, vaikka
ohjauspaine on oikea, tai venttiilistä kuuluu epätavallista
ääntä tai siinä on vuoto.
Äänet
Venttiilistä kuuluvat äänet määräytyvät käyttösovelluksen,
virtaavan aineen ja käytetyn laitetyypin mukaan. Vain
käyttäjä voi määrittää äänitason tarkasti, kun venttiili on
asennettu järjestelmään.
Ennakoiva huolto
- Tarkista venttiilin toiminta käyttämällä venttiiliä vähintään
kerran kuukaudessa.
- Jos huollon aikana ilmenee ongelmia tai sinulla on ky-
symyksiä, ota meihin tai valtuutettuun edustajaamme
yhteyttä.
Vianmääritys
- Väärä lähtöpaine: Tarkista, että venttiilin syöttöpuolen
paine vastaa tyyppikilvessä ilmoitettua painetta.
Tärkeää: minimiohjauspaine on 2 baaria.
Tarkista henkilövahingon tai laitevaurion välttämiseksi, että
venttiili toimii oikein, ennen kuin se otetaan taas käyttöön.
Varaosat
Keloja on saatavana varaosina.
Vaihda tarvittaessa koko venttiili.
ASENNUS- JA HUOLTO-OHJEET
3/2 NC
FI
Sarjan 551 solenoidiventtiilit, joissa messinkirunko, tai sarjojen 551–553 venttii-
lit, joissa ruostumaton teräsrunko, ¼”:n tai ½”:n kierteet tai NAMUR-liitäntä
5/2 - 5/3
21
20
3834901
3834901
BESKRIVELSE AF GODKENDELSEN
Versioner der falder under godkendelsen (Afbild. 1 og 11):
Messinghus (serie 551) eller hus af rustfrit stål (serierne
551, 553), monostabile (fjederretur) eller bistabile, 3/2
NC-funktion (normalt lukket) eller 5/2, version isoleret
fra den omgivende atmosfære. V
ersioner uden manuel
overstyring eller med impuls-type manuel overstyring:
- med gevindskårne porte 1/4 (551) eller 1/2 (553) - 551,
med ¼” gevindtilslutning, maks. portdybde 11,5 mm.
(Forbind ikke trykforsyningen til udløbsport 3. Den
"miljøbeskyttede" konstruktion er ikke beregnet til en
"distributionsfunktion" eller til brug i NO-funktion. Kon-
takt os med henblik på oplysning om, hvilke funktioner
der er til rådighed på bestemte modeller).
- med NAMUR interface til direkte montering på enkeltvir-
kende (funktion 3/2 NL) eller dobbeltvirkende (funktion 5/2)
pneumatisk drev. Funktionen af ventilen er konvertibel fra
3/2 NL til 5/2 ved at montere den medfølgende 13/2 NL eller
5/2 interface plade i bunden af ventilen (fi g. 13a, 13b, ref.
1a og 1b). 1/4”, maks. portdybde 11,5 mm. (Forbind ikke
trykforsyningen til udløbsport 3. Den "miljøbeskyttede"
konstruktion er ikke beregnet til NO-funktion. Kontakt
os med henblik på oplysning om, hvilke funktioner der
er til rådighed på bestemte modeller).
- Forbind rørene til de krævede funktioner, som angivet i denne
dokumentation og på port markeringerne på produktet.
- For at forkomme at ventilens funktion bliver blokeret, skal det
sikres, at der ikke kommer fremmedlegemer ind i kredsløbet.
Begræns brugen af tætningsbånd eller tætningsmateriale
til et minimum.
- Disse ventiler er beregnet til brug med ren og tør luft eller
inaktiv gas. Anbefalet minimumsfi ltrering: 50 my. Dugpunk-
tet af det medie der bliver brugt, skal ligge mindst -10°C
(18°F) under den minimumstemperatur, som mediet kan
blive udsat for. Når der bruges smurt luft, skal smøremidlet
være forenelig med de benyttede elastomere. Instrumentluft
i overensstemmende med ANSI/ISA standard S7.3 (1975)
overgår de nødvendige krav, og er derfor et acceptabelt
medie til disse ventiler.
!
Alle ventilers og styreventilers udstødningsporte
skal være beskyttet med udstødningsbeskyttere af
rustfrit stål. Sæt udstødningsbeskytterne på port 3
(3/2 NC) eller port 3 - 5 (5/2). Ved anvendelse udendørs
eller ved længere tids opbevaring, og/eller ved anven-
delse i aggressive miljøer (støv, væsker etc.), skal der
anvendes udløbsbeskyttere. Ventilens driftssikkerhed
kan ikke garanteres, hvis der anvendes andre udløbsbe-
skyttere end de medfølgende.
- Tilladte temperaturspektrum: -40° C til +80° C (serie 551);
-40° C til +60° C (serie 553).
- Maksimum arbejdstryk:
- 2 til 10 bar
- 2 til 8 bar (ISSC/PISC/PISCIS/CFSCIS/CFSDIS/CFVTIS)
BESKRIVELSE
ATEX 94/9/EC versionerne: Se "Særlige krav for sikker
brug".
Versioner isoleret fra atmosfæren: De indre dele af ven-
tilen er isolerede fra den omgivende atmosfære, for at give
beskyttelse i aggressive omgivelser. Alle udløbsåbninger kan
tilsluttes til rørledninger, hvilket giver en bedre miljømæssig
beskyttelse, især anbefalet til sensitive områder som for
eksempel rene rum, og installationer i den farmaceutiske
industri og i levnedsmiddelindustrien. Hvis spoleventilen
bliver brugt udendørs eller i ubeskyttede omgivelser (støv,
væsker o.s.v.), er det nødvendigt at tilslutte rør eller beslag til
udløbsåbningerne, for at beskytte spoleventilens indre dele.
SPECIELLE KRAV TIL SIKKER BRUG
ATEX 94/9/EC versionerne: Ventilen skal jordforbindes (se
"Montage").
Mediets maksimumstemperatur må ikke overstige omgivel-
sestemperaturen.
Spoleventilen skal opbevares i sin originale indpakning, så
længe den ikke er i brug. Den beskyttende afdækning må ikke
fjernes fra forbindingsåbningerne og magnetstyreenhederne.
Opbevaringsforhold: Beskyttet mod vejret; opbevaringstem-
peratur: -40 C til +70°C; relative fugtighedsgrad: 95 %
Efter opbevaring ved lav temperatur, skal spoleventilen
gradvist varmes op til driftstemperatur, før der bliver sat
tryk på.
Spoleventilen er beregnet til brug under de tekniske forhold,
der er specifi ceret på fabriksskiltet. Forandringer på produktet
må kun foretages efter samråd med producenten eller dennes
repræsentanter. Disse magnetspoleventiler er konstrueret
til brug med fi ltreret luft eller neutral gas. Overskrid ikke
ventilens tilladte maksimumstryk = 8/10 bar (eller 8 bar med
en Piezotronic pilotventil ifølge ATEX Ex ia). Overhold styre-
delens minimum trykværdi på 2bar. Installation og vedligehold
af ventilen må kun udføres af kvalifi ceret personale.
Standard IP65-mærket luftdrifts versioner eller versioner
til brug i eksplosive atmosfærer forårsaget af gasser, dampe,
tåge eller støv i henhold til ATEX direktiv 94/9/EC. (Zoneklas-
sifi kationen for denne version er angivet på ATEX mærket,
ref.E1).
Sikkerhedskode, serie 551: II 1 GD c T6 T85° C Ta -40° C
til +65° C
Sikkerhedskode, serie 553: II 2 GD c T6 (T85°C), - T5 (T100°C).
EF typetestcertifi kat nr. (serie 551):
INERIS 03 ATEX 0219 X
Overensstemmelse med de væsentligste helbreds- og
sikkerhedskrav er sikret ved overensstemmelse med de
europæiske standarder EN 13463-1 og EN 13463-5.
Magnet-luftdrifts versioner med indbygget magnetstyre-
enhed:
- IP65 forseglet eller
- godkendt til brug i eksplosionsfarlige omgivelser i henhold
til ATEX direktiv 94/9/EC.
Versioner med magnetstyring med ASCO montageplade,
- IP65-mærket som standard, eller til brug i eksplosive
atmosfærer II 3D IP65/IP67 eller ATEX Ex d, m, em, Ex ia
(serie 551: II 1G/2D Ex ia IIC IP65/IP67 eller serie 553: II
2G/D Ex ia IIC IP65/IP67).
Versioner med piloter med CNOMO E06.05.80 (str. 30)
eller CNOMO E06.36.120N (str. 15) montageplade,
- IP 65-mærket som standard, eller montering af piloter til
brug i eksplosive atmosfærer i henhold til ATEX Ex d eller
Ex ia.
Advarsel (CNOMO piloter): Zoneklassifi kationen (ATEX
1999/927EC) er hovedsagelig defi neret ved angivelserne
på fabriksskiltet fi g. 10 og 20 (ref. E1 eller E2) på ventil-
huset. Sikkerhedskode i henhold til ATEX direktiv 94/9/
EF: II 1 GD c T6 T85° C Ta -40° C til +65° C
EC typetest certifi kat nr.: INERIS 03 ATEX 0219 X
Ved monteringen af dette produkt på en styredel til ATEX
94/9/ECATEX 94/9/EC, skal der holdes regnskab med den
mindst gunstige, maksimum arbejdstryk temperaturkate-
gori. Overensstemmelse med de væsentligste helbreds- og
sikkerhedskrav er sikret ved overensstemmelse med de
europæiske standarder EN 13463-1 og EN 13463-5.
Styredelenes monteringsposition som den er vist i afbildnin-
gerne 4/5/14/15/21/22/23/24 og det angivne stramningsmo-
ment skal overholdes.
For magnetstyreenheder og piloter til ATEX 94/9/EC, skal
de instruktioner om brugen, der er givet i den specifi kke
installationsanvisning der fulgte med produktet, strengt
overholdes.
MONTERING
!
ATEX 94/9/EC versionerne: rg for at alt metal
eller ledende dele altid er inbyrdes forbundet og forbundet til
jordforbindelse. Ventilkassen er forbundet til jordforbindelse
med befæstelsesskruen (ref. F).
Ventilerne kan monteres i alle positioner.
Gevindskårne porte version 1/4 (fi g. 3a) 1/2 (fi g. 3b):
monter ventilen med to skruer (ref. 1) (ikke leveret).
Versioner med NAMUR-grænsefl ade (fi g. 13a, 13b):
r spoleventilen bliver monteret på aktivatoren, skal den
indstilles til den krævede funktion:
- Vælg den interface der passer til den krævede funktion: 3/2
NC eller 5/2 (ref. 1a eller 1b).
- Sørg for at pakningen er monteret rigtigt.
- Monter interface, under spoleventilens med de 2 skruer
der er leveret (ref.8).rg for at angivelsen af funktionen
INSTALLATIONS- OG VEDLIGEHOLDSANVISNINGER
3/2 NC
DK
Solenoideventiler serie 551, messinghus, eller serierne 551-553,
hus af rustfrit stål, ¼", ½" gevind eller NAMUR-grænsefl ade
5/2 - 5/3
er placeret på returløbssiden (polarisations udsparing).
- Tilpas de to O-ringe (ref. 9).
- Om nødvendigt, sæt styrepinden på operatøren:
• På 3/2 NL pladen: er Ø 5 dia. hullet ved A1.
• På 5/2 NL pladen: er Ø 5 dia. hullet ved A2.
PNEUMATISK FORBINDELSE (fi g. 3a, 3b, 13a og 13b)
Afhængigt af versionen (3/2 NL eller 5/2), skal der bruges en
eller to rustfri stål udløbsbeskyttere (se fi g. 2).
Montering af pneumatisk pilot version:
G 1/8 eller NPT 1/8 eller G 1/4 eller NPT 1/4.
Montering af pilotens udløb
Udstødningen kan opsamles som det passer bedst til den
brugte version.
Manuel overstyring
Afhængigt af versionen, er produktet leveret uden manuel
overstyring eller med impuls-type manuel overstyring
til styring uden elektricitet. Den manuelle tilsidesættelse er
angivet med symbolet ( ) på fi g. 4, 5, 14, 15, 21 til 24, og
ref. 10 på fi g. 3a, 3b, 13a, 13b.
Med den impulsstyrede eller faste (af typen tryk/drej) ma-
nuelle tilsidesættelse, der er angivet af symbolet ( ) på
g. 3a, 3b, 13a og 13b, kan der foretages betjening uden
strøm.
!
Før ventilen bliver sat i gang, skal man sikre sig
at den manuelle overstyring er drejer tilbage og koblet
fra ved position "0" for at forebygge personskader eller
skader på udstyr.
Tilpasning til ekstern pilotforsyning
(fi g. 3a, 3b, 13a og 13b, ref. 6)
Generelle anbefalinger i forbindelse med pneumatisk
montering
Forbind rørene til de krævede funktioner, som angivet i denne
dokumentation og på port markeringerne på produktet.
Sørg for at ingen fremmedlegemer kommer ind i systemet.
Understøt rørene korrekt og ret dem ind på linie, for at fore-
bygge mekanisk belastning på ventilen. Brug ikke ventilen
som håndgreb ved stramningen, men placer skruenøglen
så tæt på forbindingspunktet som muligt. For at undgå at
skade udstyret, må rørforbindelserne IKKE OVERSPÆN-
DES.
Gevindskårne porte version 1/4 (fi g. 3a) 1/2 (fi g. 3b):
Montering af spoleventilen:
Forbind rørene som vist på mærkesedlen:
- 3/2 NL funktion:
Trykindløb ved port 1 (1/4” eller 1/2” gevind). Trykudløb
ved port 2.
Udstødning ved port 3 (1/4” eller 1/2” gevind).
- 5/2 funktion:
Tryk indtag ved port 1. Tryk udløb ved portene 2 og 4.
Udstrømningen bliver ledt gennem ventilen til portene 3
og 5.
Versioner med NAMUR interface (afbild. 13a, 13b):
Montering af spoleventilen:
Forbind rørene som vist på mærket:
- 3/2 NL funktion:
Trykindløb ved port 1 (1/4” eller 1/2” gevind). Trykudløb
ved port 2.
Udløb ved port 3 (messinghus: 1/8 ; hus af rustfrit stål: 1/4"
eller 1/2" gevind). Udløb fra returoperatørens fjederkamre
i den enkeltvirkende version er ledt gennem ventilen til
1/8" Port 3. Det anbefales at beskytte port 5 (hvis den
ikke er i brug) - den må ikke tætnes.
- 5/2 funktion:
Trykindløb ved port 1 (1/4” eller 1/2” gevind). Trykudløb ved
portene 2 og 4.
Udstrømningen bliver ledt gennem ventilen til portene 3 og 5
(messinghus: 1/8 ; hus af rustfrit stål: 1/4" eller 1/2" ge-
vind).
Tilkoblingen af udløbsbegrænsere (messing hus)
Serie 551 gliderventilerne bliver leveret, som de er bestilt,
med eller uden miniature 1/8” udstødningsbegrænsere,
suffi ks M (fi g. 13a).
Disse justerbare mini udløbsbegrænsere bruges til at justere
aktivatorens driftshastighed. De kan også monteres (1/8
gevind) for at opsamle udstrømningen.
Montage / justering (fi g. 3a):
Version 3/2 NC = 1 udløbsbegrænser til montering på port
3
Version 5/2 = 2 udløbsbegrænsere til montering på portene
3 og 5
r skruen (4) på begrænseren ind i hullet og skru den ind
indtil den stopper; drej den derefter ud for at øge udløbs-
hastigheden (Aldrig mere end to omdrejninger, maks.
stømningshastighed opnås efter en omdrejning).
Stram låsemøtrikken (4a) med en 13 mm nøgle.
Indstil omtrentligt før der bliver sat tryk på, og fi njuster efter
at trykket er sat på.
ELEKTRISK FORBINDELSE
Versioner med magnetspolehoveder med ASCO inter-
face:
Se de ekstra installationsinstruktioner der følger med hvert
magnetspolehovede.
IP65-klassifi ceret solenoideoperator (fi g. 3a, 3b og 13a,
13b): Monter spolen på røret (så den kan drejes 360° rundt)
og derefter det aftagelige ISO 4400/EN 175101-803A-stik
(kabeldiameter 6-10 mm), der kan drejes 90º (3 ben: 2 +
jord).
Version med CNOMO monteringsplade:
Se de ekstra installationsinstruktioner der følger med hver
pilotventil.
Generelle anbefalinger:
Elektriske forbindelser skal udføres af kvalifi ceret personale
og i følge de gældende lokale standarder og forskrifter.
Forsigtig:
- r der foretages noget arbejde, skal den elektriske strøm
slås fra så komponenterne ikke står under spænding.
- Afhængig af strømstyrken, skal elektriske komponenter
jordforbindes i følge de lokale standarder og forskrifter.
De fl este ventiler er udstyret med spoler der er konstru-
eret til kontinuerlig drift. For at forebygge personskader
må man ikke røre magnetenheden, som kan blive meget
varm under normale driftsomstændigheder. Hvis der er
let adgang til magnetventilen, skal installatøren sørge for
beskyttelse mod kontakt med magnetenheden ved et
uheld.
VEDLIGEHOLD
!
Før der foretages noget vedligeholdsarbejde, eller
start af drift, skal den elektriske strøm slås fra, trykket
udløses og ventilen skal luftes for at forebygge person-
skader eller skader på apparatur.
ATEX-versioner: Følg omhyggeligt alle procedurer, der
anbefales af direktiv 99/92/EF og tilhørende standarder.
Rengøring
Vedligehold af ventilerne afhænger af driftsomstændigheder.
De skal gøres rent med regelmæssige mellemrum. Under
vedligeholdsarbejdet skal komponenterne ses efter for
unormal stærk slidtage. Komponenterne skal gøres rene
når man mærker en nedsættelse i cyklusens hastighed,
selvom styredelens tryk er korrekt, eller hvis der opstår en
usædvanlig lyd eller lækage.
Lyd
Lydstyrken afhænger af brugen, mediet og den type udstyr
der er brugt. Den præcise iagttagelse af lydniveauet, kan
kun blive gjort af den bruger, der har ventilen installeret i
sit system.
Forebyggende vedligehold
- Kør ventilen mindst en gang om måneden for at kontrollere
dens funktion.
- Dersom der opstår problemer under vedligeholdelsen, eller
hvis du er i tvivl om noget, bedes du kontakte os eller en
af vores autoriserede repræsentanter.
Fejllokalisering
- Forkert udstrømningstryk: Kontroller trykket på tilførsels-
siden af ventilen; det skal korrespondere med de værdier
der er angivet på fabriksskiltet.
Forsigtig: overhold minimum pilotens trykværdi på 2bar.
For at undgå personskader eller skader på apparatur,
skal der kontrolleres om ventilen fungerer korrekt, før den
sættes i drift igen.
Reservedele
Spoler er tilrådighed som reservedele.
Om nødvendigt, skift hele ventilen ud.
INSTALLATIONS- OG VEDLIGEHOLDSANVISNINGER
3/2 NC
DK
Solenoideventiler serie 551, messinghus, eller serierne 551-553,
hus af rustfrit stål, ¼", ½" gevind eller NAMUR-grænsefl ade
5/2 - 5/3
23
22
3834901
3834901
DESCRIÇÃO DA APROVAÇÃO
Versões relacionadas com a aprovação (Fig. 1 - 11):
Corpo de latão (série 551) ou de aço inoxidável (série 551,
553), monoestável (retorno da mola) ou biestável, função
3/2 NC (normalmente fechada) ou 5/2, versão isolada da
atmosfera exterior. Versões sem sobreposição manual
ou com sobreposição manual de tipo impulso:
- com portas roscadas de 1/4 (551) ou 1/2 (553) - 551, com
ligação de rosca de ¼",
profundidade de porta máx. de
11,5 mm. (Não ligue o fornecimento de pressão à porta
de escape 3. A construção “ambientalmente protegida”
não está adaptada para uma função “de distribuição”
ou utilização na função NO. Contacte-nos para saber
as funções disponíveis em versões específi cas.).
- com interface NAMUR para montagem directa de accio-
nadores pneumáticos de acção individual (função 3/2 NC)
ou acção dupla (função 5/2). A função da válvula é con-
vertível de 3/2 NC para 5/2 através da montagem da placa
de interface 13/2 NC ou 5/2 fornecida na parte inferior da
válvula (fi g.13a, 13b, ref. 1a e 1b). 551, 1/4”, profundidade
de porta máx. de 11,5 mm. (Não ligue o fornecimento de
pressão à porta de escape 3. A construção “ambiental-
mente protegida” não está adaptada para a função NO.
Contacte-nos para saber as funções disponíveis em
versões específi cas.).
- Ligue os tubos para as funções requeridas de acordo com
esta documentação e as marcas das portas no produto.
- Certifi que-se de que não entra nenhuma matéria estranha
para evitar o bloqueio do funcionamento da válvula. Restrinja
a utilização de fi ta vedante ou material vedante a um mínimo.
- Estas válvulas destinam-se à utilização com ar seco e limpo
ou gás inerte. Filtragem mínima recomendada: 50 mícrones.
O ponto de condensação do fl uído utilizado tem de estar a
pelo menos -10°C (18°F) abaixo da temperatura mínima a que
o fl uído possa estar exposto. Quando utilizar ar lubrifi cado, o
lubrifi cante tem de ser compatível com os elastómeros utili-
zados. O ar do instrumento em conformidade com as normas
ANSI/ISA S7.3 (1975) excede os requisitos necessários e é,
por isso, um fl uído aceitável para estas válvulas.
!
Tem de proteger todas as portas de saída das válvu-
las e dos pilotos com protectores de saída de aço
inoxidável. Ligue os protectores de escape à 3 (3/2
NC) ou às portas 3 - 5 (5/2). Quando utilizados no exterior
ou guardados durante períodos de tempo mais longos,
e/ou expostos a ambientes severos (poeiras, líquidos,
etc.), tem de utilizar protectores de escape. A fi abilidade
da válvula não pode ser garantida se utilizar um protec-
tor de escape diferente do fornecido.
- Intervalo de temperatura permitido: De -40°C a +80°C (série
551); de -40°C a +60°C (série 553).
- Pressão de trabalho máxima:
- de 2 a 10 bar
- de 2 a 8 bar (ISSC/PISC/PISCIS/CFSCIS/CFSDIS/CFVTIS)
DESCRIÇÃO
Versões ATEX 94/9/CE: Consulte as "Condições especiais
para utilização segura".
Versões isoladas da atmosfera: As partes internas da válvula
estão isoladas da atmosfera exterior para fornecer protecção em
ambientes agressivos. Todas as portas de saída da válvula de
carretos são ligáveis, fornecendo melhor protecção ambiente,
recomendada especialmente para áreas sensíveis, como apli-
cações e salas limpas na indústria farmacêutica ou alimentar.
É necessário ligar tubos ou acessórios às portas de saída para
proteger as partes internas da válvula de carretos, se utilizada
no exterior ou em ambientes severos (poeiras, líquidos, etc.).
CONDIÇÕES ESPECIAIS PARA UTILIZAÇÃO SEGURA
Versões ATEX 94/9/CE: A válvula tem de ser ligada à terra
(ver "Montagem").
A temperatura máxima do fl uído não deve exceder a tempe-
ratura ambiente.
A válvula de carretos deve ser mantida na embalagem original
enquanto não for utilizada. Não deve remover as tampas de
protecção das portas de ligação e dos operadores de solenóide.
Condições de armazenamento: protegida da exposição às
condições meteorológicas; temperatura de armazenamento:
de -40 C a +70°C; humidade relativa: 95 %
Depois do armazenamento a baixa temperatura, as válvu-
las de carretos têm de fi car gradualmente à temperatura
de funcionamento antes da pressurização.
As válvulas de carretos devem ser utilizadas de acordo com
as especifi cações técnicas especifi cadas na placa de identifi -
cação. As alterações aos produtos só podem ser efectuadas
após consulta ao fabricante ou ao seu representante. Estas
válvulas de carretos de solenóide foram concebidas para
operar com ar fi ltrado ou gás neutral. Não exceda pressão
máxima permitida da válvula = 8/10 bar (ou uma válvula piloto
Piezotronic de 8 bar para ATEX Ex ia). Cumpra a pressão
piloto mínima de 2 bar. A instalação e a manutenção da vál-
vula devem ser efectuadas apenas por pessoal qualifi cado.
Versões operadas a ar IP65 standard ou versões para
utilização em atmosferas explosivas provocadas por gases,
vapores, névoas ou poeiras de acordo com a Directiva ATEX
94/9/CE. (A classifi cação da zona desta versão é indicada
na etiqueta ATEX, ref. E1).
Código de segurança, série 551: II 1GD c T6 T85°C Ta De
-40°C a +65°C
Código de segurança, série 553: II 1GD c T6 (T85°C) - T5 (T100°C).
Certifi cado de verifi cação de tipo CE nº (Série 551):
INERIS 03 ATEX 0219 X
A conformidade com os requisitos essenciais de saúde e
segurança foi garantida de acordo com as normas europeias
EN 13463-1 e EN 13463-5.
Versões operadas a ar equipadas com operadores de
solenóide:
- IP65 vedada ou
- certifi cada para utilização em atmosferas explosivas de
acordo com a Directiva ATEX 94/9/CE
Versões com operadores de solenóide e base de mon-
tagem ASCO,
- IP65 classifi cada como standard, ou para utilização em
atmosferas explosivas II 3D IP65/IP67 ou ATEX Ex d, m,
em, Ex ia (Série 551: II 1G/2D Ex ia IIC IP65/IP67 ou
série 553: II 2G/D Ex ia IIC IP65/IP67).
Versões com pilotos e base de montagem CNOMO
E06.05.80 (tamanho 30) ou CNOMO E06.36.120N (tama-
nho 15),
- IP65 classifi cada como standard, ou montagem de pilotos
para utilização de acordo com a ATEX Ex d ou a Ex ia.
A classifi cação da zona (ATEX 1999/927CE) é defi nida
principalmente pelas indicações na chapa de identifi -
cação fi g. 10 e 20 (ref. E1 ou E2) no corpo da válvula.
Código de segurança de acordo com a directiva ATEX
94/9/CE: II 1 GD c T6 T85°C Ta De -40°C a +65°C
Código de segurança de acordo com a Directiva ATEX
94/9/ CE: II 1 GD c T6 T85°C Ta de -40°C a +65°C.
Certifi cado de verifi cação de tipo CE nº:
INERIS 03 ATEX 0219 X.
Quando montar este produto num piloto para ATEX 94/9/
EC, tenha em atenção a temperatura, pressão de trabalho
máxima e a categoria menos favorável. A conformidade
com os requisitos essenciais de saúde e segurança foi garan-
tida de acordo com as normas europeias EN 13463-1 e EN
13463-5. Tem de cumprir a posição de montagem dos pilotos
apresentada nas fi g. 4/5/14/15/21/22/23/24 e os binários de
aperto indicados.
Para operadores de solenóide e pilotos ATEX 49/9/CE,
as instruções de utilização fornecidas nas instruções de
instalação específi cas fornecidas com o produto têm de
ser cumpridas.
MONTAGEM
!
Versões ATEX 94/9/CE: Certifi que-se de que todas as
peças condutoras ou metálicas estão sempre interligadas e
ligadas a terra. O corpo da válvula fi ca ligado a terra com o
parafuso de aperto (ref. F).
As válvulas podem ser montadas em qualquer posição.
Versões de porta roscada 1/4 (fi g 3a), 1/2 (fi g 3b):
Monte a válvula com dois parafusos (rep. 1) (não fornecida).
Versões com interface NAMUR (fi g. 13a, 13b):
Antes de montar a válvula de carretos no operador, tem de
o defi nir para a função requerida:
- Seleccione a interface correspondente à função requerida:
3/2 NC ou 5/2 (rep. 1a ou 1b).
- Certifi que-se de que o vedante está instalado correctamente
(rep.7)
- Monte a interface debaixo da válvula de carretos com
os 2 parafusos fornecidos (rep.8). Certifi que-se de que a
INSTRUÇÕES DE INSTALAÇÃO E MANUTENÇÃO
3/2 NC
PT
Válvulas solenóides da série 551, corpo de latão, ou da série 551-
553, corpo de aço inoxidável, rosca de ¼", ½" ou interface NAMUR
5/2 - 5/3
indicação da função fi ca no lado de retorno (ranhura de
polarização).
- Instale os dois o-rings (rep. 9).
- Se necessário, instale o perno guia no operador:
Na placa de funções da 3/2 NC: o orifício de 5 de diâmetro
está na A1.
Na placa de funções da 5/2: o orifício de 5 de diâmetro
está na A2.
LIGAÇÃO PNEUMÁTICA (fi g. 3a, 3b, 13a e 13b)
Dependendo da versão (3/2 NC ou 5/2), pode utilizar um dos
protectores de saída de aço inoxidável (ver fi g. 2).
Ligação da versão de piloto pneumático: G 1/8 ou NPT
1/8 ou G 1/4 ou NPT 1/4.
Ligação de escapes do piloto
Os escapes podem ser reunidos de acordo com a versão
utilizada.
Sobreposição manual
Dependendo da versão, os produtos são fornecidos sem
sobreposição manual ou com sobreposição manual
de tipo impulso para funcionamento sem corrente. A
sobreposição manual é indicada com o símbolo (
) nas
g. 4, 5, 14, 15, 21 a 24, e ref. 10 nas fi g. 3a, 3b, 13a, 13b.
A sobreposição manual (empurrar/rodar) mantida ou de
impulso indicada pelo símbolo ( ) nas fi g. 3a, 3b, 13a e
13b permite um funcionamento sem potência.
!
Antes de a colocar em funcionamento, certifi que-se
de que a substituição manual volta à posição de desen-
grenagem "0" para evitar o risco de danos físicos ou
materiais.
Adaptação ao fornecimento do piloto externo
(fi g.3a, 3b, 13a e 13b, ref.6)
Recomendações gerais para ligação pneumática
Ligue os tubos para as funções requeridas de acordo com
esta documentação e as marcas das portas no produto.
Certifi que-se de que não entra nenhuma matéria estranha
no sistema.
Apoie e alinhe correctamente os tubos para impedir o esforço
mecânico da válvula. Quando apertar, não utilize a válvula
como uma alavanca; coloque as chaves de bocas junto ao
ponto de ligação. Para evitar danos no equipamento, NÃO
APERTE EXCESSIVAMENTE as ligações do tubo.
Versões de porta roscada 1/4 (fi g 3a), 1/2 (fi g 3b):
Ligação da válvula de carretos:
Ligue os tubos como indicado na etiqueta:
- Função 3/2 NC:
Entrada de pressão na porta 1 (Rosca de 1/4” ou ½”).
Saída de pressão na porta 2.
Escape na porta 3 (Rosca de 1/4” ou ½”).
- Função 5/2:
Entrada de pressão na porta 1. Saída de pressão nas
portas 2 e 4. Os escapes são canalizados através da
válvula para as portas 3 e 5.
Versão com interface NAMUR (fi g 13a, 13b):
Ligação da válvula de carretos
Ligue os tubos como indicado na etiqueta:
- Função 3/2 NC:
Entrada de pressão na porta 1 (Rosca de 1/4” ou ½”).
Saída de pressão na porta 2.
Escape na porta 3 (corpo de latão: 1/8 ; corpo de aço
inoxidável: rosca de 1/4" ou 1/2").
Escape a partir das câmaras da mola de retorno do ope-
rador na versão de acção individual através da válvula
para a porta 3 de 1/8". Recomendamos que proteja a
porta 5 (se não utilizada) - não a pare.
- Função 5/2:
Entrada de pressão na porta 1 (Rosca de 1/4” ou ½”).
Saída de pressão nas portas 2 e 4.
Os escapes são canalizados através da válvula para as
portas 3 e 5 (corpo de latão: 1/8 ; corpo de aço inoxidável:
rosca de 1/4" ou 1/2").
Ligação dos redutores de escape (corpo de latão):
As válvulas de carretos da série 551 são fornecidas como
encomendadas com ou sem redutores de escape de 1/8”
miniaturas, sufi xo M (fi g. 13a).
Estes redutores de escape ajustáveis são utilizados para
ajustar a velocidade de funcionamento do accionador.
Podem também ser ligados (rosca de 1/8) para recolher
os escapes.
Montagem / Ajuste (fi g. 3a):
Versão 3/2 NC = 1 redutor de escape para instalar na porta 3
Versão 5/2 = 2 redutores de escape para instalar nas portas
3 e 5
Encaixe o parafuso (4) do redutor no orifício e aparafuse-o
até parar; rode-o para aumentar o fl uxo de escape (nunca
mais de duas voltas, fl uxo máximo obtido numa volta).
Aperte a porca de fi xação (4a) com uma chave de porcas
de 13 mm.
Efectue um ajuste preliminar antes da pressurização e um
ajuste fi no depois da pressurização.
LIGAÇÃO ELÉCTRICA
Versões com cabeças solenóides com interface ASCO:
Consulte as instruções de instalação adicionais fornecidas
com todas as cabeças solenóides.
Operador de solenóide IP65 (fi g. 3a, 3b e 13a, 13b): Mon-
te a bobina no tubo (rotação de 360°) e, em seguida, o
conector ISO 4400/EN 175101-803A amovível (diâmetro
do cabo 6-10 mm) com rotação de 90° (3 pinos: 2 + terra).
Versão com base de montagem CNOMO:
Consulte as instruções de instalação adicionais fornecidas
com todas as válvulas piloto.
Recomendações gerais:
As ligações eléctricas têm de ser efectuadas por pessoal
qualifi cado e de acordo com os regulamentos e as normais
locais aplicáveis.
Precaução:
- Antes de efectuar qualquer intervenção, desligue a cor-
rente eléctrica para desactivar os componentes.
- Dependendo da voltagem, os componentes eléctricos têm
de ser ligados à terra de acordo com os regulamentos e
as normas locais.
A maior parte das válvulas está equipada com bobinas
concebidas para trabalho contínuo. Para evitar lesões
corporais, não toque no operador de solenóide que pode
car quente em condições de funcionamento normais.
Se a válvula tiver acesso fácil, o instalador deve utilizar
equipamento de protecção para evitar qualquer contacto
acidental com o operador de solenóide.
MANUTENÇÃO
!
Antes de efectuar qualquer trabalho de manutenção
ou operação, desligue a corrente eléctrica, despressurize
e descarregue a válvula para evitar lesões corporais ou
danos no equipamento.
Versões ATEX: Cumpra todos os procedimentos reco-
mendados pela Directiva 99/92/CE e normas associadas.
Limpeza
A manutenção das válvulas depende das condições de
funcionamento. Têm de ser limpas em intervalos regulares.
Deve verifi car se os componentes têm um desgaste exces-
sivo durante a assistência. Tem de limpar os componentes
quando uma desaceleração do ciclo apesar da pressão
do piloto estar correcta ou se detectar uma fuga ou ruído
pouco usual.
Emissão de som
A emissão de som depende da aplicação, material e tipo
de equipamento utilizado. A determinação exacta do nível
de som só pode ser efectuada pelo utilizador com a válvula
instalada no sistema.
Manutenção preventiva
- Opere a válvula pelo menos uma vez por mês para veri-
car o funcionamento.
- Se detectar algum problema durante a manutenção ou em
caso de dúvida, contacte-nos ou um dos representantes
autorizados.
Resolução de problemas
- Pressão de saída incorrecta: Verifi que a pressão no lado
de fornecimento da válvula; tem de corresponder aos
valores indicados na placa de identifi cação.
Precaução: cumpra valor mínimo de pressão do piloto de
2 bar.
Para evitar lesões corporais ou danos no equipamento,
verifi que se a válvula funciona correctamente antes de
a voltar a colocar em funcionamento.
Peças sobresselentes
As bobinas estão disponíveis como peças sobresselentes.
Se necessário, substitua a válvula inteira.
INSTRUÇÕES DE INSTALAÇÃO E MANUTENÇÃO
3/2 NC
PT
Válvulas solenóides da série 551, corpo de latão, ou da série 551-
553, corpo de aço inoxidável, rosca de ¼", ½" ou interface NAMUR
5/2 - 5/3
25
24
3834901
3834901
ΠΕΡΙΓΡΑΦΗ ΤΗΣ ΕΓΚΡΙΣΗΣ
Εκδόσεις που αφορά η έγκριση (Εικ. 1 και 11):
Ïñåé÷Üëêéíïò êïñìüò (óåéñÜ 551) Þ êïñìüò áíïîåßäùôïõ
÷Üëõâá (óåéñÜ 551, 553), ìïíïóôáèÞò (åðáíáöïñÜ åëáôçñßïõ)
ή äéóôáèÞò, ëåéôïõñãßá 3/2 NC (κανονικά κλειστή) ή 5/2,
Ýêäïóç áðïìïíùìÝíç áðü ôçí åîùôåñéêÞ áôìüóöáéñá. Εκδό-
σεις χωρίς μηχανική παράκαμψη ή με μηχανική παράκαμψη
παλμικού τύπου:
- με èõñßäåò ìå óðåßñùìá 1/4 (551) ή 1/2 (553) - 551, με
σύνδεση σπειρώματος ¼’’, μέγιστο βάθος θύρας 11,5mm.
(Μη συνδέετε την παροχή πίεσης στο στόμιο εξόδου 3. Η
κατασκευή μεπροστασία από συνθήκες
περιβάλλοντος
δεν είναι προσαρμοσμένη γιαδιανεμητικήλειτουργία, ή
χρήση σε λειτουργία NO. Επικοινωνήστε μαζί μας για τις
διαθέσιμες λειτουργίες σε επιμέρους εκδόσεις).
- με σύνδεση NAMUR για άμεση τοποθέτηση σε πνευματικό μη-
χανισμό απλής ενέργειας (λειτουργία 3/2 NC) ή διπλής ενεργείας
(λειτουργία 5/2). Η λειτουργία της βαλβίδας είναι εναλλασσόμενη
από 13/2 NC σε 5/2 με την τοποθέτηση της πλάκας
σύνδεσης 3/2
NC ή 5/2 που διατίθεται, στη βάση της βαλβίδας (åéê.13a, 13b,
âë. 1a και 1b). 1/4”, μέγιστο βάθος θύρας 11,5mm (Μη συν-
δέετε την παροχή πίεσης στο στόμιο εξόδου 3. Η κατασκευή
μεπροστασία από συνθήκες περιβάλλοντος δεν είναι
προσαρμοσμένη για λειτουργία NO. Επικοινωνήστε μαζί
μας για τις διαθέσιμες λειτουργίες σε επιμέρους εκδόσεις).
- Συνδέστε τους σωλήνες για τις
απαιτούμενες λειτουργίες σύμφωνα
με τα έγγραφα αυτά και τη σήμανση των στομίων στο προϊόν.
- Φροντίστε να μην εισχωρήσουν ξένα σώματα στο κύκλωμα για
να μη μπλοκάρει η λειτουργία της βαλβίδας. Περιορίστε τη χρήση
στεγανωτικής ταινίας ή στεγανωτικής ουσίας στο ελάχιστο.
- Οι βαλβίδες αυτές προορίζονται για χρήση με καθαρό και
ξηρό αέρα
ή αδρανές αέριο. Συνιστώμενη ελάχιστη διήθηση: 50 μικρά. ΤΟ
σημείο δρόσου του ρευστού που χρησιμοποιείται πρέπει να είναι
τουλάχιστον –10°C (18°F) κάτω από την ελάχιστη θερμοκρασία
στην οποία μπορεί να εκτεθεί το ρευστό. Όταν χρησιμοποιείται
λιπαινόμενος αέρας, το λιπαντικό πρέπει να είναι συμβατό με τα
ελαστομερή που χρησιμοποιούνται. Ο εργαστηριακός αέρας κατά
το πρότυπο ANSI/ISA S7.3 (1975) υπερκαλύπτει τις απαραίτητες
προϋποθέσεις και αποτελεί, επομένως, ένα αποδεκτό ρευστό
για τις βαλβίδες αυτές.
!
Ïëåò ïé èýñåò åêôüíùóçò ôùí âáëâßäùí êáé ôùí ðéëüôùí
ðñÝðåé íá ðñïóôáôåýïíôáé ìå ôá ðñïóôáôåõôéêÜ åêôïíùôþí
áíïîåßäùôïõ ÷Üëõâá. Συνδέστε τα προστατευτικά για
στόμιο εξόδου στη θύρα 3 (3/2 NC) ή θύρες 3 - 5 (5/2).
Κατά την εξωτερική χρήση, ή κατά την αποθήκευση για με-
γάλο χρονικό διάστημα και/ή κατά την έκθεση σε διαβρωτικά
περιβάλλοντα (σκόνες, υγρά κλπ.), πρέπει να χρησιμοποι-
ούνται προστατευτικά για στόμια εξόδου. Η αξιοπιστία της
βαλβίδας δεν μπορεί να εγγυηθεί
εάν χρησιμοποιείται προ-
στατευτικό για στόμιο εξόδου διαφορετικό από το συγκεκρι-
μένο που παρέχεται.
- Επιτρεπόμενη θερμοκρασία: -40°C έως +80°C (σειρά 551),
-40°C έως +60°C (σειρά 553).
- Μέγιστη πίεση λειτουργίας:
- 2 έως 10 bar
- 2 έως 8 bar (ISSC/PISC/PISCIS/CFSCIS/CFSDIS/CFVTIS)
ΠΕΡΙΓΡΑΦΗ
Εκδόσεις ATEX 94/9/ΕΚ: Δείτε την ενότηταΕιδικοί όροι
ασφαλούς χρήσης”.
Εκδόσεις απομονωμένες από την ατμόσφαιρα: Τα εσωτερικά
εξαρτήματα της βαλβίδας είναι απομονωμένα από το εξωτερικό
περιβάλλον με σκοπό την εξασφάλιση προστασίας σε επιθετικά
περιβάλλοντα. Όλα τα στόμια εξόδου της εμβολοβαλβίδας διασω-
ληνώνονται, παρέχοντας καλύτερη
περιβαλλοντική προστασία,
κάτι που συνιστάται ιδιαίτερα σε ευαίσθητους τομείς όπως οι
καθαροί χώροικαι εφαρμογές της φαρμακοβιομηχανίας ή της
βιομηχανίας τροφίμων. Είναι αναγκαίο να συνδέσετε σωλήνες ή
υδραυλικά εξαρτήματα στα στόμια εξόδου για να προστατεύσετε
τα εσωτερικά εξαρτήματα της εμβολοβαλβίδας, όταν αυτή χρησι-
μοποιείται εξωτερικά ή σε σκληρό περιβάλλον ( σκόνες
, υγρά κλπ.).
ΕΙΔΙΚΟΙ ΟΡΟΙ ΑΣΦΑΛΟΥΣ ΧΡΗΣΗΣ
Εκδόσεις ATEX 94/9/ΕΚ: Η βαλβίδα πρέπει να γειωθεί (δείτε
την ενότηταΣυναρμολόγηση”).
Η μέγιστη θερμοκρασία του ρευστού δεν πρέπει να ξεπερνά τη
θερμοκρασία περιβάλλοντος.
Η εμβολοβαλβίδα πρέπει να διατηρείται στην αρχική της
συσκευασία για όσο διάστημα δεν χρησιμοποιείται. Τα προστα-
τευτικά καλύμματα δεν πρέπει να αφαιρούνται
από τα στόμια
σύνδεσης και τους ηλεκτρομαγνητικούς μηχανισμούς.
Συνθήκες αποθήκευσης: απαιτείται προστασία από τα καιρικά
φαινόμενα, θερμοκρασία αποθήκευσης: -40°C έως +70°C,
σχετική υγρασία: 95 %
Μετά την αποθήκευση σε χαμηλή θερμοκρασία, οι εμβολο-
βαλβίδες πρέπει να αποκτήσουν σταδιακά τη θερμοκρα-
σία λειτουργίας πριν την εφαρμογή πίεσης σε αυτές.
Οι εμβολοβαλβίδες προορίζονται για χρήση στα
πλαίσια των
τεχνικών χαρακτηριστικών που καθορίζονται στην πινακίδα
τους. Αλλαγές στα προϊόντα επιτρέπονται μόνον αφού συμβου-
λευθείτε τον κατασκευαστή ή τον αντιπρόσωπό του. Αυτές οι
ηλεκτρομαγνητικές εμβολοβαλβίδες έχουν σχεδιαστεί για
λειτουργία με φιλτραρισμένο πεπιεσμένο αέρα ή ουδέτε-
ρο αέριο. Μην υπερβαίνετε τη μέγιστη επιτρεπτή πίεση στη
βαλβίδα = 8/10 bar (ή 8 bar με
πιεζοτρονική πιλοτική βαλβίδα
κατά ATEX Ex ia). Τηρήστε την ελάχιστη τιμή πιλοτικής πίεσης
2 bar. Η εγκατάσταση και συντήρηση της βαλβίδας πρέπει να
εκτελείται μόνο από εξειδικευμένο προσωπικό.
Εκδόσεις πεπιεσμένου αέρα, διαβάθμισης IP65, ή εκδόσεις για
χρήση σε εκρηκτικό περιβάλλον που δημιουργούν αέρια, ανα-
θυμιάσεις, νέφη ή σκόνες, σύμφωνα με την Οδηγία ATEX 94/9/
ΕΚ. (Η ζώνη ταξινόμησης
αυτής της έκδοσης επισημαίνεται στην
πινακίδα ATEX, σημ. E1).
Κωδικός ασφαλείας, σειρά 551: II 1GD c T6 T85°C Ta -40°C
Ýùò +65°C
Κωδικός ασφαλείας, σειρά 553: II 2GD c T6 (T85°C) - T5
(T100°C)
Πιστοποιητικό εξέτασης τύπου EC αρ. (Σειρά 551): INERIS 03
ATEX 0219 X
Ç óõììüñöùóç ìå ôéò Ïõóéþäåéò áðáéôÞóåéò õãéåéíÞò êáé
áóöÜëåéáò åîáóöáëßæåôáé äéáìÝóïõ ôçò óõììüñöùóçò ìå
ôá ÅõñùðáúêÜ Ðñüôõðá EN 13463-1 και EN 13463-5.
Εκδόσεις που λειτουργούν με ηλεκτρομαγνήτη και πεπιεσμένο
αέρα εξοπλισμένες με ηλεκτρομαγνητικό μηχανισμό:
- στεγανοποιημένες κατά IP65 ή
- πιστοποιημένες για χρήση σε εκρηκτικό περιβάλλον σύμφωνα
με την Οδηγία
ATEX 94/9/ΕΚ
Εκδόσεις με ηλεκτρομαγνητικό μηχανισμό και βάση στήριξης
ASCO
- διαβάθμισης IP65 ή για χρήση σε εκρηκτικό περιβάλλον II 3D
IP65/IP67 ή κατά ATEX Ex d, m, em, Ex ia (Σειρά 551: II 1G/2D
Ex ia IIC IP65/IP67 ή σειρά 553: II 2G/D Ex ia IIC IP65/IP67).
Εκδόσεις με πιλοτικό μηχανισμό και βάση στήριξης CNOMO
E06.05.80 (μέγεθος 30) ή CNOMO E06.36.120N (μέγεθος 15),
- διαβάθμισης IP 65, ή για χρήση σε εκρηκτικό περιβάλλον κατά
ATEX Ex d ή Ex ia.
Προσοχή ( πιλοτικοί μηχανισμοί CNOMO): Η κατάταξη ζώνης
(ATEX 1999/927EC) προσδιορίζεται κατά κύριο λόγο από
τις ενδείξεις στην πινακίδα εικ. 10 και 20 (βλ. E1 ή E2) στον
κορμό της βαλβίδας. Κωδικός ασφαλείας σύμφωνα με την
Οδηγία ATEX 94/9/EΟΚ: II 1GD c T6 T85°C Ta -40°C Ýùò
+65°C
Πιστοποιητικό εξέτασης τύπου EC αρ.: INERIS 03ATEX0219 X.
Κατά τη συναρμολόγηση αυτού του προϊόντος σε πιλοτικό
μηχανισμό κατά ATEX 94/9/ΕΚ, πρέπει
να λαμβάνεται η λιγό-
τερο ευνοϊκή κατηγορία, mέγιστη πίεση λειτουργίας και θερμο-
κρασία. Ç óõììüñöùóç ìå ôéò Ïõóéþäåéò áðáéôÞóåéò õãéåéíÞò
êáé áóöÜëåéáò åîáóöáëßæåôáé äéáìÝóïõ ôçò óõììüñöùóçò ìå
ôá ÅõñùðáúêÜ Ðñüôõðá EN 13463-1 και EN 13463-5. ÐñÝðåé íá
ôçñïýíôáé ç èÝóç ôïðïèÝôçóçò ôùí ðéëüôùí üðùò åéêïíßæåôáé
óôá ó÷Þìáôá 4/5/14/15/21/22/23/24 και ïé áíáöåñüìåíåò
ñïðÝò óýóöéîçò.
Για τους ηλεκτρομαγνητικούς μηχανισμούς και τους πιλοτι-
κούς μηχανισμούς κατά ATEX 49/9/ΕΚ, πρέπει να τηρούνται
οι οδηγίες χρήσης καθώς και οι συγκεκριμένες οδηγίες
εγκατάστασης που διατίθενται με το προϊόν.
ΣΥΝΑΡΜΟΛΟΓΗΣΗ
!
Εκδόσεις ATEX 94/9/ΕΚ: Φροντίστε όλα τα μεταλλικά ή
αγώγιμα μέρη να είναι πάντα διασυνδεδεμένα μεταξύ τους και
συνδεδεμένα με τη γείωση. Το σώμα της βαλβίδας συνδέεται με
τη γείωση, μέσω της βίδας σύσφιξης (σημ. F).
Οι βαλβίδες μπορούν να τοποθετηθούν σε οποιαδήποτε θέση.
Åêäüóåéò èýñáò ìå óðåßñùìá 1/4 (åéê 3a), 1/2 (åéê 3b):
Τοποθετήστε τη βαλβίδα με τις δύο βίδες ( σημ. 1) (δεν
διατίθενται).
Åêäüóåéò με äéáóýíäåóç NAMUR (εικ. 13a, 13b):
Πριν την τοποθέτηση της εμβολοβαλβίδας στον μηχανισμό, πρέπει
να τη ρυθμίσετε στην απαιτούμενη λειτουργία.
- Επιλέξτε τη βάση σύνδεσης που αντιστοιχεί στην απαιτούμενη
λειτουργία: 3/2 NC ή 5/2 (σημ. 1a ή 1b).
- Βεβαιωθείτε ότι η τσιμούχα έχει τοποθετηθεί σωστά (σημ. 7).
- Τοποθετήστε τη βάση σύνδεσης κάτω από την εμβολοβαλβίδα
ΟΔΗΓΙΕΣ ΕΓΚΑΤΑΣΤΑΣΗΣ ΚΑΙ ΣΥΝΤΗΡΗΣΗΣ
3/2 NC
GR
Çëåêôñïâáëâßäåò óåéñÜò 551, ìå ïñåé÷Üëêéíï êïñìü, Þ óåéñÜò 551-553, ìå
êïñìü áðü áíïîåßäùôï ÷Üëõâá, óðåßñùìá 1/4“, 1/2" Þ äéáóýíäåóç NAMUR
5/2 - 5/3
με τις 2 βίδες που διατίθενται (σημ. 8). Βεβαιωθείτε ότι η ένδειξη
της λειτουργίας βρίσκεται στην πλευρά της επιστροφής ( υποδοχή
πόλωσης).
- Τοποθετήστε τις δύο τσιμούχες (σημ. 9).
- Αν χρειαστεί, τοποθετήστε τον φυτευτό πείρο στον μηχανισμό:
Στη βάση λειτουργίας 3/2 NC: η τρύπα διαμέτρου O 5 είναι στο
A1.
Στη βάση λειτουργίας 5/2: η τρύπα διαμέτρου O 5 είναι στο
A2.ÐÍÅÕÌÁÔÉÊÇ ÓÕÍÄÅÓÇ (εικ. 3a, 3b, 13a και 13b)
Ανάλογα με ôçí Ýêäïóç (3/2 NC ή 5/2), ìðïñïýí íá
÷ñçóéìïðïéçèïýí Ýíá Þ äýï ðñïóôáôåõôéêÜ åêôüíùóçò áðü
áíïîåßäùôï ÷Üëõâá (βλ. εικ. 2).
Σύνδεση της έκδοσης με πνευματικό πιλοτικό μηχανισμό:
G 1/8 ή NPT 1/8 ή G 1/4 ή NPT 1/4.
Σύνδεση εξαγωγών πιλοτικού μηχανισμού
Οι εξαγωγές μπορούν να συλλέγονται σε συλλέκτη, ανάλογα
με την έκδοση που χρησιμοποιείται.
Μηχανική παράκαμψη
Ανάλογα με την έκδοση, τα προϊόντα διατίθενται χωρίς
μη-
χανική παράκαμψη ή με μηχανική παράκαμψη παλμικού
τύπου για λειτουργία χωρίς ρεύμα. Ç ÷åéñïêßíçôç ðáñÜêáìøç
õðïäåéêíýåôáé ìå ôï óýìâïëï (
) óôçí åéκ. 4, 5, 14, 15, 21
Ýùò 24, και âë. 10 óôçí åéκ. 3a, 3b, 13a, 13b.
Ç ÷åéñïêßíçôç ðáñÜêáìøç êñïõóôéêïý ôýðïõ Þ äéáôÞñçóçò
(ôýðù ðßåóçò êáé ðåñéóôñïöÞò) ðïõ õðïäçëþíåôáé ìå ôï
óýìâïëï (
) óôçí åéκ. 3a, 3b, 13a και 13b επιτρέπει ôç
ëåéôïõñãßá ÷ùñßò éó÷ý.
!
Πριν από τη θέση σε λειτουργία, φροντίστε να γυρίσετε
τον μηχανισμό μηχανικής παράκαμψης σε θέση απε-
μπλοκήςΟγια να αποτραπεί ο κίνδυνος τραυματισμού
ή ζημιάς του εξοπλισμού.
Προσαρμογή σε εξωτερική πιλοτική παροχή (εικ.3a, 3b,
13a και 13b, βλ. 6)
Γενικές συστάσεις για την πνευματική σύνδεση
Συνδέστε τους σωλήνες για τις απαιτούμενες λειτουργίες σύμ-
φωνα με τα έγγραφα αυτά και τη σήμανση των στομίων στο
προϊόν.
Φροντίστε να μην εισχωρήσουν ξένα σώματα στο σύστημα.
Στηρίξτε κατάλληλα και ευθυγραμμίστε τους σωλήνες για να
μην αναπτύσσονται μηχανικές τάσεις στη βαλβίδα. Κατά
τη
σύσφιξη, μη χρησιμοποιείτε τη βαλβίδα ως μοχλό, τοποθετήστε
τα εργαλεία όσο το δυνατόν πιο κοντά στο σημείο σύνδεσης.
Για να αποφύγετε ζημιά στον εξοπλισμό, ΜΗ ΣΦΙΓΓΕΤΕ ΥΠΕΡ-
ΒΟΛΙΚΑ τις συνδέσεις των σωλήνων.
Åêäüóåéò èýñáò ìå óðåßñùìá 1/4 (åéê 3a), 1/2 (åéê 3b):
Σύνδεση της εμβολοβαλβίδας:
Συνδέστε τους σωλήνες όπως φαίνεται στην πινακίδα:
- Λειτουργία 3/2 NC:
Είσοδος πίεσης στην
θύρα 1 (με σπείρωμα 1/4” ή 1/2”).
¸îïäïò ðßåóçò óôç èýñá 2.
Åêôüíùóç óôç èýñá 3 (óðåßñùìá 1/4” ή 1/2”).
- Λειτουργία 5/2:
Είσοδος πίεσης στο στόμιο 1. Έξοδος πίεσης στα στόμια 2
και 4.
Οι εξαγωγές περνούν μέσα από τη βαλβίδα και καταλήγουν
στα στόμια 3 και 5.
Έκδοση με σύνδεση NAMUR (εικ. 13a):
Σύνδεση της εμβολοβαλβίδας:
Συνδέστε τους σωλήνες όπως φαίνεται στην πινακίδα:
- Λειτουργία 3/2 NC:
Είσοδος
πίεσης στην θύρα 1 (με σπείρωμα 1/4” ή 1/2”).
¸îïäïò ðßåóçò óôç èýñá 2.
Εξαγωγή στο στόμιο 3 (ïñåé÷Üëêéíïò êïñìüò: 1/8, êïñìüò
áíïîåßäùôïõ ÷Üëõâá: óðåßñùìá 1/4" Þ 1/2"). Η εξαγωγή
από τους θαλάμους του ελατηρίου επιστροφής του μηχανι-
σμού απλής ενεργείας διοχετεύεται μέσω της βαλβίδας στο
στόμιο 3 1/8". Προτείνεται προστασία του στομίου 5 (αν δεν
χρησιμοποιείται) - μην το φράζετε.
- Λειτουργία 5/2:
Åßóïäïò ðßåóçò óôçí èýñá 1 (ìå óðåßñùìá 1/4” ή 1/2”).
Έξοδος πίεσης στα στόμια
2 και 4.
εξαγωγές περνούν μέσα από τη βαλβίδα και καταλήγουν στα
στόμια 3 και 5 (ïñåé÷Üëêéíïò êïñìüò: 1/8, êïñìüò áíïîåßäùôïõ
÷Üëõâá: óðåßñùìá 1/4" Þ 1/2").
l
Σύνδεση των μειωτήρων εξαγωγής (ορειχάλκινο σώμα):
Ïé åìâïëïåéäåßò âáëâßäåò óåéñÜò 551 ðáñÝ÷ïíôáé áíÜëïãá ìå
ôçí ðáñáããåëßá ìå Þ ÷ùñßò óõóôïëÝò åîáãùãÞò ìéíéáôïýñáò
1/8”, ðáñÝêôáìá M (εικ. 13a).
Αυτοί οι ρυθμιζόμενοι μικρομειωτήρες εξαγωγής χρησιμοποιού-
νται για τη ρύθμιση της ταχύτητας λειτουργίας του μηχανισμού.
Μπορούν επίσης να συνδεθούν ( σπείρωμα 1/8") για τη συλλογή
των εξαγωγών.
Óõíáñìïëüãçóç / Ñýèìéóç (εικ. 3a):
Έκδοση 3/2 NC = 1 μειωτήρας εξαγωγής στο στόμιο 3
Έκδοση 5/2 = 2 μειωτήρες εξαγωγής στα στόμια 3 και 5
Συνδέστε τη βίδα (4) στο μειωτήρα μέσα από την οπή και βιδώστε
τη μέχρι το τέρμα, στη συνέχεια ξεβιδώστε την για να αυξηθεί
η ροή της εξαγωγής (ποτέ περισσότερο από δύο στροφές,
η μέγιστη ροή επιτυγχάνεται στη μία στροφή
).
Σφίξτε το ασφαλιστικό παξιμάδι (4a) με κλειδί 13 mm.
Κάντε χονδρική ρύθμιση πριν από τη συμπίεση και λεπτή ρύθ-
μιση μετά τη συμπίεση.
ΗΛΕΚΤΡΙΚΗ ΣΥΝΔΕΣΗ
Έκδοση με ηλεκτρομαγνητικές κεφαλές και σύνδεση ASCO:
Δείτε τις πρόσθετες οδηγίες εγκατάστασης που διατίθενται με
κάθε ηλεκτρομαγνητική κεφαλή.
Χειριστής ηλεκτροβαλβίδων κατηγορίας IP65 (εικ. 3a, 3b και
13a, 13b): Τοποθετήστε το πηνίο στον σωληνίσκο (δυνατό-
τητα περιστροφής 360°) και στη συνέχεια τον αφαιρούμενο
συνδετήρα ISO 4400/EN 175101-803A (διάμ. καλωδίου 6-10
mm) που περιστρέφεται κατά 90° (3 ακίδες: 2 + ãåßùóç).
Έκδοση με βάση τοποθέτησης CNOMO:
Δείτε τις πρόσθετες οδηγίες εγκατάστασης που
διατίθενται με
κάθε πιλοτική βαλβίδα.
Γενικές συστάσεις:
Οι ηλεκτρικές συνδέσεις πρέπει να γίνουν από εξειδικευμένο
προσωπικό και σύμφωνα με τις κατά τόπους ισχύουσες διατά-
ξεις και κανονισμούς.
Προσοχή:
- Πριν από οποιαδήποτε παρέμβαση, κλείστε την παροχή
ρεύματος για να απενεργοποιήσετε τα εξαρτήματα.
- Ανάλογα με την τάση, τα ηλεκτρικά εξαρτήματα
πρέπει να
γειώνονται σύμφωνα με τις κατά τόπους ισχύουσες διατάξεις
και κανονισμούς.
Οι περισσότερες βαλβίδες διαθέτουν πηνίο σχεδιασμένο για
συνεχή λειτουργία. Για να αποτραπεί ο κίνδυνος τραυματι-
σμού, μην αγγίζετε τον ηλεκτρομαγνητικό μηχανισμό, οποίος
μπορεί να καίει πολύ σε κανονικές συνθήκες λειτουργίας. Αν
η βαλβίδα έχει εύκολη πρόσβαση, ο εγκαταστάτης
πρέπει να
εξασφαλίσει προστασία που να μην επιτρέπει τυχαία επαφή
με τον ηλεκτρομαγνητικό μηχανισμό.
ΣΥΝΤΗΡΗΣΗ
!
Πριν από κάθε εργασία συντήρησης ή τη θέση σε λειτουρ-
γία, διακόψτε την παροχή ρεύματος, αποσυμπιέστε και εξαε-
ρώστε τη βαλβίδα για να αποτραπεί κίνδυνος τραυματισμού ή
ζημιάς του εξοπλισμού.
Åêäüóåéò ATEX: ÔçñÞóôå áðáñÝêêëéôá üëåò ôéò äéáäéêáóßåò
ðïõ óõíéóôÜ ç Ïäçãßá 99/92/EC êáé ôá óõíáöÞ ðñüôõðá.
Καθαρισμός
Η συντήρηση των βαλβίδων εξαρτάται από τις συνθήκες λειτουρ-
γίας. Πρέπει να καθαρίζονται σε τακτά χρονικά διαστήματα.
Κατά
τη συντήρηση, πρέπει να γίνεται έλεγχος των εξαρτημάτων για
υπερβολική φθορά. Τα εξαρτήματα πρέπει να καθαρίζονται αν
παρατηρηθεί επιβράδυνση του κύκλου, ακόμα και αν η πιλοτική
πίεση είναι σωστή, ή αν εντοπιστεί ασυνήθιστος θόρυβος ή
διαρροή.
Εκπομπή θορύβου
Η εκπομπή θορύβου εξαρτάται από την εφαρμογή, το μέσο και
τον
τύπο του εξοπλισμού που χρησιμοποιείται. Ο ΑΚΡΙΒΗΣ
ΠΡΟΣΔΙΟΡΙΣΜΟΣ ΤΗΣ ΣΤΑΘΜΗΣ ΘΟΡΥΒΟΥ ΜΠΟΡΕΙ ΝΑ
ΓΙΝΕΙ ΜΟΝΟ ΑΠΟ ΤΟΝ ΧΡΗΣΤΗ ΜΕ ΤΗ ΒΑΛΒΙΔΑ ΤΟΠΟ-
ΘΕΤΗΜΕΝΗ ΣΤΟ ΣΥΣΤΗΜΑ.
Προληπτική συντήρηση
- Λειτουργήστε τη βαλβίδα τουλάχιστον μία φορά το μήνα για
να ελέγξετε τη λειτουργία της.
- Εάν åìöáíéóôïýí ðñïâëÞìáôá êáôÜ ôç óõíôÞñçóç Þ Ý÷åôå
áìöéâïëßåò, ðáñáêáëïýìå επικοινωνήστε ìáæß ìáò Þ ìå
êÜðïéï åîïõóéïäïôçìÝíï áíôéðñüóùðï.
Αντιμετώπιση προβλημάτων
- Λανθασμένη
πίεση εξόδου: Ελέγξτε την πίεση στην πλευρά
εισόδου της βαλβίδας, πρέπει να ανταποκρίνεται στις τιμές
που επισημαίνονται στην πινακίδα.
Προσοχή: τηρήστε την ελάχιστη τιμή πιλοτικής πίεσης 2 bar.
Για να αποφευχθεί τραυματισμός ή ζημιά στον εξοπλισμό,
ελέγξτε αν η βαλβίδα λειτουργεί σωστά πριν την βάλετε πάλι
σε λειτουργία.
Ανταλλακτικά
Τα πηνία είναι διαθέσιμα ως ανταλλακτικά.
Αν χρειαστεί, αντικαταστήστε ολόκληρη τη βαλβίδα.
ΟΔΗΓΙΕΣ ΕΓΚΑΤΑΣΤΑΣΗΣ ΚΑΙ ΣΥΝΤΗΡΗΣΗΣ
3/2 NC
GR
Çëåêôñïâáëâßäåò óåéñÜò 551, ìå ïñåé÷Üëêéíï êïñìü, Þ óåéñÜò 551-553, ìå
êïñìü áðü áíïîåßäùôï ÷Üëõâá, óðåßñùìá 1/4“, 1/2" Þ äéáóýíäåóç NAMUR
5/2 - 5/3
27
26
3834901
3834901
Návod k instalaci a údržbě
3/2 NC
CZ
Elmg. ventily řady 551, mosazné těleso, nebo řady 551-553, těleso
z nerezavějící oceli, 1/4“, 1/2" závit nebo uspořádání NAMUR
5/2
POPIS SCHVÁLENÍ
Verze zahrnuté do schválení (obr. 1 a 11):
Mosazné těleso (řada 551) nebo těleso z nerezavějící
oceli (řada 551, 553), monostabilní (vratná pružina) nebo
bistabilní, 3/2 NC (rozpínací) funkce nebo 5/2, verze izo-
lovaná od okolního prostředí. Verze s ručním ovládáním
nebo bez něho.
- s otvory Ľ“ (551) se závitem nebo ½“ (553) - 551, s Ľ
pozlaceným konektorem, Max. hloubka portu 11,5 mm.
(Nepřipojujte tlakový zdroj k výstupnímu portu 3. Kon-
strukce „chránící prostředí“ není přizpůsobena pro funkci
„distribuce“ nebo použití BEZ funkce. Kontaktujte nás
pro funkce dostupné v určitých verzích).
- s uspořádáním NAMUR pro přímou montáž na jednočinný
(funkce 3/2 NC) nebo dvojčinný (funkce 5/2) pneumatický
pohon. Funkci ventilu lze měnit z 3/2 NC na 5/2 namonto-
váním dodané desky rozhraní 3/2 NC nebo 5/2 na spodní
stranu ventilu (obr.13a, 13b, ref. 1a a 1b). 551, max. 1/4”
hloubka portu = 11,5 mm. (Nepřipojujte tlakový zdroj
k výstupnímu portu 3. Konstrukce „chránící prostředí“
není přizpůsobena pro použití BEZ funkce Kontaktujte
nás pro funkce dostupné v určitých verzích).
Připojte potrubí pro požadované funkce podle této dokumen-
tace a označení otvorů na výrobku.
- Zajistěte, aby se do obvodu nedostala žádná cizí látka, aby
nedošlo k zablokování funkce ventilu. Omezte na minimum
použití těsnicí pásky nebo těsnicí hmoty.
- Ventily jsou ur
čeny pro použití s čistým a suchým vzduchem
nebo inertním plynem. Doporučená minimální ltrace: 50
mikronů. Rosný bod kapaliny musí být alespoň -10 °C pod
minimální teplotou, které může být kapalina vystavena. Při
použití mazacího vzduchu musí být mazivo kompatibilní s
použitými elastomery. Přístrojový vzduch odpovídající normě
ANSI/ISA S7.3 (1975) převyšuje nezbytné požadavky a je
proto pro tyto ventily přijatelnou kapalinou.
!
Všechny výfukové otvory ventilů a pilotů musí být
chráněny chráničem z nerezavějící oceli. Připojte
chrániče výfuku k portu 3 (3/2 NC) nebo portům 3 – 5
(5/2) ventilů. Při použití venku, nebo při dlouhodobém
skladování, nebo při vystavení působení drsného pro-
středí (prachy, kapaliny a podobně) chrániče musí být
použity. Při použití jiného chrániče než toho, který byl
dodán s výrobkem, nelze garantovat spolehlivost venti-
lu.
- Přípustný teplotní rozsah:
-40 °C až +80 °C (řada 551); -40 °C až +60 °C (řada 553).
- Max. rozsah provozního tlaku:
-2 až 10 barů
- 2 až 8 barů (ISSC/PISC/PISCIS/CFSCIS/CFSDIS/
CFVTIS)
OBECNÝ POPIS
Verze ATEX 94/9/EC: Viz „Speciální podmínky pro bezpeè-
né použíVerze ATEX 94/9/EC: Viz „Speciální podmínky pro
bezpečné používání“.
Verze izolované od okolního prostředí: Vnitřčásti ventilu
jsou izolovány od okolního prostředí, aby byla zajištěna
ochrana v agresivních prostředích. Všechny výfukové otvory
cívkového ventilu lze připojit k potrubí, což poskytuje lepší
ochranu životního prostředí, a zvláště se to doporučuje v
citlivých oblastech, např. v čistých provozech a aplikacích
ve farmaceutickém nebo potravinářském průmyslu. K výfuko-
vým portům je třeba připojit potrubí nebo armaturu, aby byly
chráněny vnitřčásti cívkového ventilu, je-li použit venku, v
drsném prostředí (prachy, kapaliny atd.).
SPECIÁLNÍ PODMÍNKY PRO BEZPEČNÉ POUŽÍVÁNÍ
ATEX 94/9/EC: Ventil musí být uzemněn (viz „Montáž“).
Maximální teplota kapaliny nesmí převýšit okolní teplotu.
Cívkový ventil ponechte v originálním balení, dokud ho ne-
budete používat. Nesnímejte ochranné kryty z připojovacích
otvorů a solenoidních pohonů.
Podmínky pro skladování: chraňte před povětrnostními vlivy-
;teplota skladování: -40 C až +70 °C ; relativní vlhkost: 95 %
Při skladování v nízkých teplotách musí být cívkové
ventily před zvýšením tlaku postupně zahřáty na poko-
jovou teplotu.
Cívkové ventily je možné používat v rámci technických cha-
rakteristik uvedených na typovém štítku. Změny vybavení
jsou povoleny pouze po konzultaci s výrobcem nebo jeho
zástupcem. Elmg. cívkové ventily jsou určeny pro použití
s ltrovaným vzduchem nebo neutrálním plynem. nepře-
kračujte max. přípustný tlak ventilu 10 barů (nebo 8 barů s
pilotním ventilem Piezotronic podle směrnice ATEX Ex ia).
Upozornění: Sledujte minimální tlak pilota 2 bary. Instalaci
a údržbu ventilu smí provádět pouze kvali kované osoby.
Standardní, vzduchem ovládané verze s krytím IP65
nebo verze pro použití ve výbušném prostředí vyvolaném
plyny, výpary, mlhou nebo prachem podle Směrnice ATEX
94/9/EC. (Klasi kace zóny pro tuto verzi je stanovena na
typovém štítku ATEX, ref. E1).
Bezpečnostní kód, řada 551: II 1GD c T6 T85 °C Ta -40 °C
až +65 °C
Bezpečnostní kód, řada 553: II 2GD c T6 (T 85 °C) - T5 (T
100 °C)
Číslo certi kátu typové zkoušky EC (Řada 551):
INERIS 03 ATEX 0219 X
Shoda se základními požadavky na ochranu zdraví a bezpeč-
nost je zajištěna shodou s evropskými normami EN 13463-1
a EN 13463-5.
Elmg. verze ovládané vzduchem osazené solenoidním
pohonem:
- krytí IP65 nebo certi kovány pro použití ve výbušném pro-
středí podle Směrnice ATEX 94/9/EC.
Verze se solenoidním pohonem s montážní deskou
ASCO, standardně s krytím IP65, nebo pro použití ve výbuš-
ném prostředí II 3D IP65/IP67 nebo ATEX EEx d, m, em, ia
(Řada 551: II 1G/2D Ex ia IIC IP65/IP67 nebo řada 553: II
2G/D Ex ia IIC IP65/IP67).
Verze s piloty s montážní deskou CNOMO E06.05.80
(velikost 30) nebo CNOMO E06.36.120N (velikost 15),
standardně s krytím IP 65, nebo s namontovanými piloty pro
použití ve výbušném prostředí podle ATEX EEx d nebo Ex ia.
Upozornění (piloty CNOMO): Klasi kace zóny (ATEX
1999/927EC) je de nována zejména označením na typo-
vém štítku obr. 10 a 20 (ref. E1 nebo E2) na tělese ventilu.
Bezpečnostní kód podle Směrnice ATEX 94/9/EC: II 1GD
c T6 T85 °C Ta -40 °C až +65 °C
Číslo certi kátu typové zkoušky EC: INERIS 03 ATEX 0219 X
Při sestavování výrobku s pilotem podle směrnice ATEX
94/9/EC použijte nejméně příznivou kategorii a teplo-
tu. Shoda se základními požadavky na ochranu zdraví a
bezpečnost je zajištěna shodou s evropskými normami EN
13463-1 a EN 13463-5. Montážní pozice pilotů je uvedena na
obrázcích 4/5/14/15/21/22/23/24. Je třeba dodržet vyznačené
utahovací momenty.
U solenoidních pohonů a pilotů podle směrnice ATEX 49/9/
EC je třeba přísně dodržovat pokyny k používání uvedené
v konkrétním Návodu k instalaci dodaném s výrobkem.
MONTÁŽ
!
Verze ATEX 94/9/EC: Všechny kovové a vodivé části
musí být vždy vzájemně propojeny a uzemněny. Těleso
ventilu je uzemněno pomocí upevňovacího šroubu (ref. F).
Ventily lze namontovat v libovolné pozici.
Verze s otvory se závitem Ľ“ (obr. 3a), ½“ (obr. 3b):
Namontujte ventil pomocí dvou šroubů (ref. 1) (nejsou sou-
částí dodávky).
Verze s uspořádáním NAMUR (obr. 13a, 13b):
Před namontováním cívkového ventilu na ovládací člen musí
být ventil nastaven na požadovanou funkci:
- Zvolte desku rozhraní odpovídající požadované funkci: 3/2
NC nebo 5/2(ref. 1a nebo 1b).
- Zkontrolujte, zda je těsněřádně usazeno (ref. 7).
- Namontujte desku rozhraní pod cívkový ventil pomocí 2
dodaných šroubů (ref. 8) a sledujte směr montáže. Zkon-
trolujte, zda je označení funkce umístěno na vratné straně
Installation and Maintenance Instructions
3/2 NC
CZ
Series 551 solenoid valves, brass body, or series 551-553, stainless
steel body, 1/4“, 1/2" thread or NAMUR interface
5/2
(polarizační otvor).
- Nasaďte dva o-kroužky (ref. 9).
- V případě potřeby umístěte polarizační pin na ovládací člen.
Polarizační otvor o průměru 5 na desce rozhraní 3/2 je A1.
Polarizační otvor o průměru 5 na desce rozhraní 5/2 je A2.
PŘIPOJENÍ VZDUCHU (obr. 3a, 3b, 13a a 13b)
V závislosti na verzi (3/2 NC nebo 5/2) lze použít jeden
nebo oba chrániče výstupu z nerezavějící oceli (viz obr. 2).
Připojení verze s pneumatickým pilotem:
G 1/8 nebo NPT 1/8 nebo G 1/4 nebo NPT 1/4.
Připojení výfuků pilota
Výfukové otvory lze vybrat podle použité verze.
Ruční ovládání
V závislosti na verzi se výrobky dodávají s ručním ovládáním
nebo bez něho pro provoz bez napájení. Ruční ovládání
je označeno symbolem (
) na obr. 4, 5, 14, 15, 21 až 24,
a ref. 10 na obr. 3a, 3b, 13a, 13b.
Pulsní typ nebo s ručním ovládáním (typ push/turn) ozna-
čené symbolem ( ) na obr. 3a, 3b, 13a a 13b umožňují
provoz bez napájení.
!
Před uvedením do provozu se přesvědčte, zda je
ruční ovládání vypnuto do polohy 0, abyste zabráni-
li nebezpečí úrazu nebo poškození zařízení.
Přizpůsobení pro externího pilota (obr. 3a, 3b, 13a a
13b, ref. 6)
Obecná doporučení pro připojení vzduchu
Potrubí vhodně podepřete a vyrovnejte, aby nedocházelo
k mechanickému namáhání ventilu. Při dotahování nepo-
užívejte ventil jako páku. Umístěte klíče co nejblíže k bodu
připojení. Abyste zabránili poškození zařízení, NEUTAHUJ-
TE PŘÍLIŠ připojení potrubí.
Verze s otvory se závitem 1/4“ (obr. 3a), 1/2“ (obr. 3b):
Připojení cívkového ventilu:
Připojte potrubí podle označení na štítku:
- Funkce 3/2 NC:
Tlakový vstup - otvor 1 (1/4” nebo 1/2” závit). Tlakový
výstup - otvor 2.
Výfuk - otvor 3 (1/4” nebo 1/2” závit).
- Funkce 5/2:
Tlakový vstup - otvor 1. Tlakový výstup - otvory 2 a 4.
Výfuk je veden ventilem do otvorů 3 a 5.
Verze s uspořádáním NAMUR (obr. 13a, 13b):
Připojení cívkového ventilu:
Připojte potrubí podle označení na štítku:
- Funkce
-3/2 NC:
Tlakový vstup - otvor 1 (1/4” nebo 1/2” závit). Tlakový
výstup - otvor 2.
Výfuk - otvor 3.
(mosazné těleso: 1/8; těleso z nerezavějící oceli: 1/4" nebo
1/2" závit).
Výfuk z komor vratné pružiny jednočinného aktuátoru je
veden cívkovým ventilem do otvoru 3. Toto je doporučení
zajišťující ochranu otvoru 5 (není-li použit). Nepoužívejte
těsnění.
- Funkce 5/2:
Tlakový vstup - otvor 1 (1/4” nebo 1/2” závit).
Tlakový výstup - otvory 2 a 4.
Výfuk je veden ventilem do otvorů 3 a 5
(mosazné těleso: 1/8; těleso z nerezavějící oceli: 1/4" nebo
1/2" závit).
Připojení redukcí výfuků (mosazné těleso)
Cívkové ventily řady 551 se dodávají dle objednávky s nebo
bez miniaturní redukce výfuku 1/8", index M (obr. 13a).
Tyto nastavitelné miniaturní redukce výfuku se používají
k nastavení provozní rychlosti aktuátoru. Dají se rovněž
připojit (1/8 závit) tak, aby shromažďovaly výfukové plyny.
Montáž / Seřízení (obr. 3a):
Verze 3/2 NC = 1 výfuková redukce se namontuje na otvor 3
Verze 5/2 = 2 výfukové redukce se namontují na otvory 3 a 5
Vložte šroub (4) na redukci do otvoru a zašroubujte ho
až na doraz. Potom jím otočte tak, abyste zvýšili průtok
výfukových plynů (ne více než o dvě otáčky, max. průtok
získáte po jedné otáčce).
Dotáhněte pojistnou matici (4a) 13mm klíčem.
Před zvýšením tlaku proveďte hrubé nastavení a po zvýšení
tlaku jemné doladění.
ELEKTRICKÉ ZAPOJENÍ
Verze se solenoidním pohonem s rozhraním ASCO: Viz
další pokyny k instalaci dodané s konkrétním solenoidním
pohonem.
Solenoidem ovládaný IP65 (obr. 3a, 3b a 13a, 13b): Na-
montujte cívku na trubičku (otočnou o 360°) a potom na
snímatelný konektor ISO 4400/EN 175101-803A (průměr
kabelu 6-10 mm) otočný o 90° (3 piny: 2 + zem).
Verze s montážní dekou CNOMO:
Viz další pokyny k
instalaci dodané s konkrétním pilotním ventilem.
Obecná doporučení:
Elektrické zapojení musí provést kvali kovaná osoba podle
platných místních norem a předpisů.
Nepřehlédněte:
- Před zahájením práce vypněte elektrický proud napájející
komponenty.
- V závislosti na napětí musí být elektrické komponenty
uzemněny podle místních norem a předpisů.
Většina ventilů je vybavena cívkami určenými pro nepřetržitý
provoz. Nedotýkejte se solenoidního pohonu, který může
být za normálních provozních podmínek horký, aby nedošlo
k úrazu. Pokud je ventil snadno přístupný, musí se montér
chránit před náhodným kontaktem se solenoidním pohonem.
ÚDRŽBA
!
Před prováděním jakékoli údržby nebo uváděním do
provozu ventil vypněte, snižte tlak a odvzdušněte,
abyste zabránili nebezpečí úrazu nebo poškození zařízení.
Verze ATEX: Přísně dodržujte všechny postupy dopo-
ručené Směrnicí 99/92/EC a přidruženými normami.
Čiště
Údržba ventilů souvisí s provozními podmínkami. Ventily
se musí pravidelně čistit. Během servisních prací je třeba
zkontrolovat, zda nejsou komponenty nadměrně opotře-
beny. Komponenty je třeba vyčistit, pokud zpozorujete
zpomalování cyklu, dokonce i tehdy, když je v pořádku tlak
v pilotu, nebo v případě zjištění neobvyklého zvuku nebo
netěsnosti.
Emise hluku
Přesné stanovení hladiny hluku může provést pouze uži-
vatel po nainstalování ventilu do systému. Emise hluku
závisí na aplikaci, kapalině a typu použitého vybavení.
Preventivní údržba
- Ventil použijte alespoň jednou měčně, abyste zkont-
rolovali jeho
funkčnost.
- Pokud během údržby narazíte na potíže nebo si
nebudete jisti, obraťte se na nás nebo na některého z
našich autorizovaných zástupců.
Odstraňování problémů
- Nesprávný výstupní tlak: Zkontrolujte tlak na vstupní
straně ventilu.
Tlak musí odpovídat hodnotám uvedeným na typovém
štítku.
Upozornění: Dodržujte minimální hodnotu tlaku pilota 2
bary.
Než uvedete ventil opět do provozu, zkontrolujte, zda
funguje správně, abyste zabránili úrazu nebo poškození
zařízení.
Náhradní díly
Cívky jsou k dispozici jako náhradní díly.
V případě potřeby vyměňte celý ventil.
29
28
3834901
3834901
Instrukcje instalacyjne i konserwacyjne
3/2 NC
PL
Seria 551 zawory solenoidowe, korpus z brązu, lub seria 551-553,
korpus ze stali nierdzewnej, gwint 1/4", 1/2" lub interfejs NAMUR
5/2
OPIS ZATWIERDZENIA
Wersje, których dotyczy zatwierdzenie (rys. 1 oraz 11).
Korpus z brązu (seria 551) lub korpus ze stali nierdzewnej
(seria 551, 553), monostabilny (zwrot sprężyny) lub dwusta-
bilny, 3/2 NC (normalnie zamknięta) funkcja lub 5/2, wersja
izolowana od atmosfery zewnętrznej. Wersje z lub bez
sterowania ręcznego kasującego nastawienie urządzenia
przez regulator automatyczny.
- z gwintowanymi 1/4 (551) lub 1/2 (553) portami - 551, z połą-
czeniem gwintowanym Ľ”, maks. głębokość portu 11,5 mm.
(Nie podłączać zasilania w ciśnienie do portu wyjściowego
3. Konstrukcja “chroniona środowiskowo” nie jest przy-
stosowana do funkcji “dystrybucyjnej” lub wykorzystania
BEZ funkcji. Prosimy skontaktować się z nami w sprawie
funkcji dostępnych w poszczególnych wersjach).
- z interfejsem NAMUR do bezpośredniego montowania do
pojedynczego działania (funkcja 3/2 NC) lub podwójnego dzia-
łania (funkcja 5/2) pneumatycznych urządzeń uruchamiających.
Funkcja zaworu jest wymienialna z 3/2 NC na 5/2 poprzez
zamontowanie załączonej płyty interfejsowej 3/2 NC lub 5/2
na dnie zaworu (rys. 13a, 13b, ref. 1a oraz 1b). 551, maks.
głębokość portu 1/4” = 11,5 mm. (Nie podłączać zasilania w
ciśnienie do portu wyjściowego 3. Konstrukcja “chroniona
środowiskowo” nie jest przystosowana do wykorzystania
BEZ funkcji. Prosimy skontaktować się z nami w sprawie
funkcji dostępnych w poszczególnych wersjach).
Podłącz rury w zakresie pożądanych funkcji zgodnie z niniejszą
dokumentacją oraz oznaczeniami portów na produkcie.
- Upewnij się, że do obwodu nie dostały się żadne obce przed-
mioty mogące zablokować działanie zaworu. Ogranicz użycie
taśmy uszczelniającej lub środka uszczelniającego do minimum.
- Zawory te są przeznaczone do użytkowania z czystym i suchym
powietrzem lub gazem obojętnym. Zalecana ltracja minimalna:
50 mikronów. Punkt rosy użytego płynu musi wynosić przynaj-
mniej -10°C (18°F) poniżej minimalnej temperatury, na której
działanie płyn ten może być wystawiony. W przypadku używania
naoliwionego powietrza, smar musi być zgodny z użytymi ela-
stomerami. Powietrze instrumentalne zgodnie ze standardem
ANSI/ISA S7.3 (1975) przewyższa niezbędne wymagania, i stąd
też, jest dopuszczalnym płynem dla tych zaworów.
!
Wszystkie porty wylotowe zaworów i pilotów muszą
być zabezpieczone ochraniaczami wylotów wykona-
nymi ze stali nierdzewnej. Podłącz te zabezpieczenia
wydmuchów do portu 3 (3/2 NC) lub portów 3 – 5 (5/2)
zaworów. W przypadku używania na zewnątrz, lub prze-
chowywania przez dłuższy okres czasu i/lub w przypadku
wystawienia na działanie ostrego otoczenia (kurz, płyny,
itd.), należy używać zabezpieczeń wydmuchów. Wiarygod-
ność zaworu nie może być zagwarantowania w przypadku
używania innego zabezpieczenia wydmuchu niż ten do-
starczony.
- Dopuszczalny zasięg temperatur:
-40°C do +80°C (seria 551); -40°C do +60°C (seria 553).
- Zasięg maksymalnego ciśnienia operującego:
-2 do 10 barów
-2 do 8 barów
(ISSC/PISC/PISCIS/CFSCIS/CFSDIS/CFVTIS)
OPIS OGÓLNY
Wersje ATEX 94/9/WE: Patrz „Specjalne warunki związane z bezpiecz-
nym użytkowaniem”
Wersje odizolowane od atmosfery: Wewnętrzne części zaworu
są odizolowane od atmosfery zewnętrznej w celu zapewnienia
zabezpieczenia w środowiskach agresywnych. Wszystkie porty
wydmuchów zaworu szpulowego mają możliwość przyłączenia rur,
co zapewnia lepsze zabezpieczenia środowiska, i jest szczególnie
rekomendowane w przypadku obszarów delikatnych takich jak
czyste pomieszczenia oraz zastosowania w przemysłach farma-
ceutycznym i przetwarzania żywności. Niezbędne jest podłączenie
rur lub instalacji do portów wydmuchów w celu zabezpieczenia
części wewnętrznych zaworu szpulowego w momencie użytko-
wania na zewnątrz lub w środowisku ostrym (kurze, płyny, itd.).
SPECJALNE WARUNKI ZWIĄZANE Z BEZPIECZNYM UŻYTKOWANIEM
ATEX 94/9/WE: Zawór musi być podłączony do uziemienia (patrz
„Montaż”).
Maksymalna temperatura płynu nie może przekraczać temperatury
otoczenia.
Zawór szpulowy musi być przechowywany w opakowaniu orygi-
nalnym tak długo, jak pozostaje on nieużywany. Osłony zabezpie-
czające nie powinny być usuwane z portów łączeń i operatorów
solenoidowych.
Warunki przechowywania: Zabezpieczone przed wystawieniem na
działanie pogody; Temperatura przechowywania: -40 C do +70°C
; wilgotność względna: 95 %
Po przechowywaniu w niskiej temperaturze, zawory szpu-
lowe muszą być stopniowo przyzwyczajane do temperatury
pokojowej przed utrzymywaniem zwiększonego ciśnienia.
Zawory szpulowe są przeznaczone do działania w obrębie tech-
nicznych cech charakterystycznych określonych na tabliczce zna-
mionowej. Zmiany w sprzęcie dozwolone są tylko po konsultacji z
producentem lub jego przedstawicielem. Te solenoidowe zawory
szpulowe są zaprojektowane tak, aby działały z powietrzem
prze ltrowanym lub gazem neutralnym. Nie należy przekra-
czać maksymalnego dozwolonego ciśnienia zaworu
= 10 barów
(lub 8 barów z zaworem pilotowym Pieztronic dla ATEX EEx ja).
Uwaga: Przestrzegaj minimalnego ciśnienia pilota o wartości 2
barów. Instalacja oraz konserwacja zaworu musi być wykonywana
wyłącznie przez wykwali kowany personel.
Standardowe wersje operujące powietrzem o wskaźniku
IP65 lub wersje do użytkowania w atmosferach wybuchowych
spowodowanych przez gazy, pary, mgły lub pyły zgodnie z
Dyrektywą ATEX 94/9/WE. (Klasy kacja stref dla tej wersji
wskazana jest na tabliczce znamionowej ATEX, referencja E1).
Kod bezpieczeństwa, seria 551: II 1GD c T6 T85°C Ta -40°C do +65°C
Kod bezpieczeństwa, seria 553: II 2GD c T6 (T85°C) - T5
(T100°C)
Certy kat badań WE nr (Seria 551): INERIS 03 ATEX 0219 X
Zgodność z Istotnymi Wymaganiami Zdrowotnymi i Bezpieczeń-
stwa została zapewniona poprzez zgodność ze Standardami
Europejskimi EN 13463-1 oraz EN 13463-5.
Solenoidowe wersje operujące powietrzem instalowane z
solenoidowymi operatorami:
- o wskaźniku IP65 lub autoryzowane wersje do użytkowania w
atmosferach wybuchowych zgodnie z Dyrektywą ATEX 94/9/WE.
Wersje z solenoidowymi operatorami z płytką mocującą
ASCO, o wskaźniku IP65 w ramach standardu, lub do użytkowania
w atmosferach wybuchowych II 3D IP65/IP67 lub ATEX EEx d, m,
em, ia (Seria 551: II 1G/2D Ex ia IIC IP65/IP67 lub serie 553: II
2G/D Ex ia IIC IP65/IP67).
Wersje z pilotami z płytką mocującą CNOMO E06.05.80 (roz-
miar 30) lub CNOMO E06.36.120N (rozmair 15), o wskaźniku IP
65 w ramach standardu, lub zamontowaniu pilotów używanych
w atmosferach wybuchowych zgodnie z ATEX EEx d lub Ex ia.
Uwaga (piloty CNOMO): Klasy kacja strefy (ATEX 1999/927
WE) jest głównie zde niowana poprzez wskazania znajdujące
się na płytce znamionowej rys. 10 oraz 20 (referencja E1 lub
E2) na korpusie zaworu. Kod bezpieczeństwa zgodnie z Dy-
rektywą ATEX 94/9/WE: II 1GD c T6 T85°C Ta -40°C do +65°C
Certy kat badań WE nr INERIS 03 ATEX 0219 X
W momencie montowania tego produktu do pilota dla ATEX
94/9/WE, należy przyjąć najmniej korzystną kategorię i tem-
peraturę. Zgodność z Istotnymi Wymaganiami Zdrowotnymi
i Bezpieczeństwa została zapewniona poprzez zgodność ze
Standardami Europejskimi EN 13463-1 oraz EN 13463-5. Pozycja
montowania dla pilotów tak, jak zostało to wskazane na rysunkach
4/5/14/15/21/22/23/24 i wskazane naprężające momenty obrotowe
muszą być przestrzegane.
W przypadku operatorów solenoidowych oraz pilotów dla
ATEX 49/9/WE, instrukcje użytkowania podane w specy-
cznych Instrukcjach Instalacyjnych dostarczone razem z
produktem, muszą być ściśle przestrzegane.
MONTAŻ
!
Wersje ATEX 94/9/WE: Upewnij się, że wszystkie części metalo-
we lub przewodzące są zawsze podłączone wzajemnie oraz
podłączone do uziemienia. Korpus zaworu jest podłączony do uziemie-
nia przy pomocy śruby mocującej (ref. F).
Zawory mogą być montowane w każdej pozycji.
Gwintowane wersje portu 1/4 (rys. 3a), 1/2 (rys. 3b):
Zamontuj zawór przy użyciu dwóch śrub (ref. 1) (nie dostar-
czona).
Wersje z interfejsem NAMUR (rys. 13a, 13b):
Przed zamontowaniem zaworu szpulowego na urządzenie
uruchamiającym, należy nastawić je na wymagane działanie:
- Wybierz płytę interfejsową, która odpowiada wymaganej funkcji:
3/2 lub5/2 (referencja 1a lub 1b).
- Upewnij się, że uszczelka jest właściwie umiejscowiona (ref. 7).
- Zamontuj płytę interfejsową pod zaworem szpulową za pomocą
2 dostarczo
-
nych śrub (ref. 8), przestrzegaj kierunku monto-
wania. Upewnij się, że wska
-
zówka funkcji umieszczona jest
na stronie zwrotnej (gniazdko polaryzujące)
Instrukcje instalacyjne i konserwacyjne
3/2 NC
PL
Seria 551 zawory solenoidowe, korpus z brązu, lub seria 551-553,
korpus ze stali nierdzewnej, gwint 1/4", 1/2" lub interfejs NAMUR
5/2
- Zainstaluj dwa pierścienie o przekroju okrągłym (ref. 9).
- Umieść bolec polaryzujący na urządzeniu uruchamiającym,
jeśli okaże się to niezbędne:
Gniazdo polaryzujące Ø 5 na płycie interfejsowej 3/2 znajduje
się w A1.
polaryzujące Ø 5 na płycie interfejsowej 5/2 znajduje się w A2.
POŁĄCZENIE PNEUMATYCZNE (rys. 3a, 3b, 13a oraz 13b)
W zależności od wersji (3/2 NC lub 5/2), można użyć jedno
lub dwa zabezpieczenia wylotu wykonane ze stali nierdzewnej
(patrz rys. 2).
Podłączenie wersji z pneumatycznym pilotem:
G 1/8 lub NPT 1/8 lub G 1/4 lub NPT 1/4.
Podłączenie wydmuchów pilota
Wydmuchy mogą być zbierane zgodnie z użytą wersją.
Sterowanie ręczne kasujące nastawienie urządzenia przez
regulator automatyczny
W zależności od wersji, produkty dostarczane są z lub bez
sterowania ręcznego kasującego nastawienie urządzenia
przez regulator automatyczny w celu obsługi bez prądu.
Sterowanie ręczne kasujące nastawienie urządzenia przez
regulator automatyczny oznaczone jest symbolem ( ) na rys.
4, 5, 14, 15, 21 do 24, i referencja 10 na rys. 3a, 3b, 13a, 13b.
Sterowanie ręczne kasujące nastawienie urządzenia przez
regulator automatyczny typu impulsowego lub wstrzymanego
(typ naciśnij/skręć) wskazane symbolem ( ) na rys. 3a, 3b,
13a oraz 13b pozwala na obsługę bez mocy (prądu).
!
Przed uruchamianiem, upewnij się, że sterowanie ręczne
kasujące nastawienie urządzenia przez regulator automa-
tyczny ustawiony jest w pozycji odłączającej „0” w celu za-
pobiegania przed ryzykiem zranienia osób lub uszkodzenia
sprzętu.
Przystosowanie do zewnętrznego zasilania pilota (rys.3a,
3b, 13a et 13b, ref. 6)
Ogólne zalecenia w zakresie połączenia pneumatycz-
nego
Zabezpiecz we właściwy sposób i wyrównaj (ustaw w
szeregu) rury celem zabezpieczenia przed mechnicznym
obciążeniem na zaworze. W momencie dokręcania, nie uży-
waj zaworu jako dźwigni; umieść klucze na tyle na ile jest to
możliwe przy punkcie złą czania. Aby uniknąć uszkodzenia
sprzęty, NIE ZAKRĘCAJ NADMIERNIE połączeń rurowych.
Gwintowane wersje portu 1/4 (rys. 3a), 1/2 (rys. 3b):
Podłączenie zaworu szpulowego:
Podłącz rury, tak, jak zostało to wskazane na etykiecie:
- funkcja 3/2 NC:
Wlot ciśnienia przy porcie 1 (gwint 1/4” lub 1/2”). Wylot ciśnienia
przy porcie 2.
Wylot przy porcie 3 (gwint 1/4” lub 1/2”).
- funkcja 5/2:
Wlot ciśnienia przy porcie 1. Wyloty ciśnienia przy porcie 2
i 4.
Wydmuchy są prowadzone przez zawór do portów 3 i 5.
Wersje z interfejsem NAMUR (rys. 13a, 13b):
Podłączenie zaworu szpulowego:
Podłącz rury, tak, jak zostało to wskazane na etykiecie:
- funkcja 3/2 NC:
Wlot ciśnienia przy porcie 1 (gwint 1/4” lub 1/2”). Wylot ciśnienia
przy porcie 2.
Wylot przy porcie 3.
(korpus z brązu: 1/8 ; korpus ze stali nierdzewnej: gwint 1/4"
lub 1/2").
Wylot ze zwrotnych komór sprężynowych działającego
pojedynczo urządzenia uruchamiającego jest prowadzony
poprzez zawór szpulowy do portu 3. Zaleca się ochronę portu
5 (w przypadku, gdy nie jest używany). Nie uszczelniaj go.
- funkcja 5/2:
Wlot ciśnienia przy porcie 1 (gwint 1/4” lub 1/2”).
Wylot ciśnienia przy portach 2 i 4.
Wyloty są prowadzone przez zawór do portów 3 i 5.
(korpus z brązu: 1/8 ; korpus ze stali nierdzewnej: gwint 1/4" lub 1/2").
Podłączenie reduktorów wylotu (korpus z brązu)
Zawory szpulowe srii 551 są dostarczane zgodnie z
zamówieniem razem z lub bez małych 1/8” reduktorów
wydmuchu, su ks M (rys. 13a). Te możliwe do regulacji
mini reduktory wydmuchu używane są do regulowania
szybkości działania urządzenia uruchamiającego. Mogą być
one podłączone także (1/8 gwint) w celu zbierania wydmu-
chów.
Montaż / Regulacja (rys. 3a):
Wersja 3/2 NC = 1 reduktor wydmuchu dopasowany do
portu 3
Wersja 5/2 NC = 2 reduktory wydmuchu dopasowane do
portów 3 i 5
Umieść śrubę (4) na reduktorze w otworze i dokręć j
ą; na-
stępnie wykręć aby zwiększyć przpływ wydmuchów (nigdy
nie wykonuj więcej niż dwa obroty, maksymalny przepływ
uzyskany przy jednym obrocie).
Dokręć przeciwnakrętkę (4a) za pomocą 13 mm klucza.
Dokonaj pobieżnej regulacji przed utrzmywaniem zwiększo-
nego ciśnienia a następnie wykonaj dokładną regulację.
PODŁĄCZENIE ELEKTRYCZNE
Wersje z solenoidowymi operatorami z interfejsem
ASCO: Patrz dodatkowe instrukcje instalacyjne dostarczone
z każdym operatorem solenoidowym.
Operator solenoidowy ze wskaźnikiem IP65 (rys. 3a, 3b oraz
13a, 13b): Zamontuj cewkę na rurze (możliwą do obracania w
zakresie 360°) a następnie możliwy do usunięcia łącznik ISO
4400/EN 175101-803A (średnica kabla 6 - 10 mm) możliwy
do obracania w zakresie 90° (3 kołki: 2 + uziemienie).
Wersje z płytką mocującą CNOMO: Patrz dodatkowe
instrukcje instalacyjne dostarczone z każdym zaworem pilo-
towym.
Ogólne zalecenia:
Podłączenia elektryczne muszą być wykonane przez wy-
kwali kowany personel i zgodnie z mającymi zastosowanie
lokalnymi standardami i przepisami.
Prosimy o zwrócenie uwagi:
- Przed rozpoczęciem jakiejkolwiek pracy, wyłącz prąd
elektryczny w celu odłączenia od zasilania wszystkich
komponentów.
- W zależności od napięcia, komponenty elektryczne muszą
być uziemione zgodnie z lokalnymi standardami i przepisami.
Większość zaworów jest wyposażona w cewki w celu za-
pewnienia ciągłej pracy. Aby zapobiec ryzyku zranienia osób,
nie należy dotykać solenoidowego operatora, który to może
nagrzać się w trakcie normalnych warunków pracy. Jeśli zawór
jest łatwo dostępny, instalator musi zapewnić zabezpieczenie
przed przypadkowym kontaktem z operatorem solenoidowym.
KONSERWACJA
!
Przed wykonaniem jakichkolwiek prac konserwatoryjnych
lub uruchamianiem, należy odłączyć zasilanie, zmniejszyć
ciśnienie i wywietrzyć zawór w celu zapobiegania rycyku zra-
nienia osób lub uszkodzenia sprzętu.
Wersje ATEX: Postępuj ściśle zgodnie ze wszystkimi pro-
cedurami rekomendowanymi przez Dyrektywę 99/92/WE i
związane standardy/normy.
• Czyszczenie
Konserwacja zaworów jest zależna od warunków pracy urzą-
dzenia. Muszą być one czyszczone w regularnych przerwach.
Podczas serwisowania, części składowe muszą być spraw-
dzane pod względem nadmiernego zużycia. Części składowe
muszą być czyszczone w momencie zauważenia zwolnienia
procesu, nawet wtedy, gdy ciśnienie pilota jest właściwe, lub
w przypadku wykrycia niezwykłego hałasu albo przecieku.
Emisja dźwięku
Dokładne ustalenie poziomu dźwięku może być przeprowa-
dzone tylko przez użytkownika mającego zawór zainstalowany
w swoim systemie. Emisja dźwięku zależy od zastosowania,
płynu oraz rodzaju użytego sprzętu.
Konserwacja zapobiegawcza
- Uruchamiaj zawór przynajmniej raz na miesiąc, w celu
sprawdzenia jego działania.
- W przypadku problemów w trakcie konserwacji, lub w razie
jakichkolwiek wątpliwości, prosimy o skontaktowanie się z
nami lub z jednym z naszych autoryzowanych przedstawicieli.
Rozwiązywanie problemów
- Niewłaściwe ciśnienie wyjściowe: Sprawdź ciśnienie po
stronie zasilającej zaworu; musi ono odpowiadać warto-
ściom wskazanym na płytce znamionowej.
Uwaga: Przestrzegaj minimalnego ciśnienia pilota o wartości
2 barów.
Aby uniknąć zranienia osób lub uszkodzenia sprzętu, spraw-
dzaj, czy zawór działa w sposób prawidłowy zanim ponownie
go uruchomisz do działania.
Części zamienne
Cewki dostępne są w ramach części zamiennych.
Jeśli jest to niezbędne, należy wymienić cały zawór.
31
30
3834901
3834901
Telepítési és karbantartási útmutató
3/2 NC
HU
551-es széria: mágnesszelepek, sárgaréz ház, vagy 551–553-as széria:
rozsdamentesacél ház, 1/4"-es, 1/2"-es menet vagy NAMUR felület
5/2
A JÓVÁHAGYÁS LEÍRÁSA
A jóváhagyás által érintett változatok (1. és 11. ábra):
Sárgaréz ház (551-es széria) vagy rozsdamentesacél
ház (551-es, 553-as széria), monostabil (rugós helyreto-
lás) vagy bistabil, 3/2-es NC (nyitó) funkció vagy 5/2-es,
környezeti levegőtől elszigetelt változat. Változatok kézi
vezérléssel van a nélkül.
- 1/4-es (551) vagy 1/2-es (553) menetes nyílások - 551,
1/4” menetes csatlakozással, max. furatmélység 11,5 mm.
(A 3. kimeneti csatlakozóra ne csatlakoztassa a nyomó
vezetéket. A “környzetvédelmi” felépítésben az “elosztó”
funkció nem került megvalósításra vagy NO funkcióval
rendelkezik. Az egyes elérhető verziókkal kapcsolatban
vegye fel velünk a kapcsolatot).
- NAMUR felülettel az egyszeres (3/2-es NC funkció)
vagy kétszeres (5/2-es funkció) működésű pneumatikus
működtetőszervekre történő közvetlen felszereléshez. A
szelep működése átalakítható 3/2-es NC-ről 5/2-esre a
mellékelt 3/2-es NC vagy 5/2-es illesztőlemez felszere-
lésével a szelep aljára (13a., 13b. ábra, 1a. és 1b. pont).
551, max. 1/4” furatmélység = 11,5 mm. (A 3. kimeneti
csatlakozóra ne csatlakoztassa a nyomó vezetéket.
A “környzetvédelmi” felépítésben a NO funkció nem került
megvalósításra. Az egyes elérhető verziókkal kapcsolat-
ban vegye fel velünk a kapcsolatot).
Csatlakoztassa a kívánt funkciók csővezetékeit a jelen do-
kumentációnak és a terméken szereplő nyílásjelzéseknek
megfelelően.
- Biztosítsa, hogy ne juthasson idegen anyag a körbe, mert az
blokkolhatja a szelep működését. A tömítőszalagok és egyéb
tömítőanyagok használatát korlátozza minimálisra.
- Rendeltetésük szerint ezek a szelepek tiszta és száraz leve-
gővel vagy semleges gázzal használhatók. A javasolt minimális
szűrés 50 mikron. A használt közeg harmatpontja legalább 10
°C-kal (18 °F) kisebb legyen annál a minimális hőmérsékletnél,
amelynek a közeg ki lehet téve. Kenőanyagot tartalmazó levegő
használata esetén a kenőanyagnak kompatibilisnek kell lennie
a használt elasztomerekkel. A műszerlevegő az ANSI/ISA S7.3
szabvány (1975) értelmében túlteljesíti a szükséges köve-
telményeket, vagyis elfogadható közeg a szelepek számára.
!
A szelepek és pilotok valamennyi kilépőnyílását
rozsdamentes acélból készült kiáramlásvédővel kell
védeni. Ezeket a kiáramlásvédőket a szelepek 3-as
(3/2-es NC) vagy 3–5-ös (5/2-es) nyílására csatlakoztassa.
Ha a szelepeket a szabadban használják, hosszabb ide-
ig tárolják, illetve kedvezőtlen körülményeknek (porok,
folyadékok stb.) teszik ki, akkor kötelező kiáramlásvédőket
használni. A mellékelttől eltérő kiáramlásvédő használa-
ta esetén a szelep megbízhatósága nem szavatolható.
- Megengedett hőmérséklet-tartomány:
-40 - +80 °C (551-es széria); -40 - 60 °C (553-as széria)
- Maximális üzeminyomás-tartomány:
-2 - 10 bar
-2 - 8 bar (ISSC/PISC/PISCIS/CFSCIS/CFSDIS/CFVTIS)
ÁLTALÁNOS LEÍRÁS
ATEX 94/9/EK változatok: lásd „A biztonságos használat
speciális feltételei” című részt.
Környezeti levegőtől elszigetelt változatok: A szelepek bel-
ső alkatrészei el vannak szigetelve a környezeti levegőtől, ami
agresszív környezetben védelmet nyújt számukra. A környezet
védelme érdekében az útszelep valamennyi kifúvónyílására
csővezeték csatlakoztatható, ami kifejezetten javasolt az
érzékeny területeken, például a tiszta helyiségekben, illetve
a gyógyszeripari és élelmiszer-feldolgozó ipari alkalmazá-
sokban. A szabadban vagy kedvezőtlen körülmények (por,
folyadékok stb.) között használt útszelep belső alkatrészeinek
védelmére a kifúvónyílásokra csővezetéket vagy szerelvényt
kell csatlakoztatni.
A BIZTONSÁGOS HASZNÁLAT SPECIÁLIS FELTÉTELEI
ATEX 94/9/EK: a szelepet csatlakoztatni kell a földhöz (lásd:
„Szerelés”).
A közeg maximális hőmérséklete nem haladhatja meg a
környezeti hőmérsékletet.
Az útszelepet az eredeti csomagolásában kell tartani mind-
addig, amíg használatba nem veszik. A csatlakozónyílásokról
és a szolenoidokról nem szabad eltávolítani a védőborítást.
Tárolási körülmények: az időjárás hatásaitól védett helyen;
tárolási hőmérséklet: -40 – 70 °C; relatív páratartalom: 95%
Az alacsony hőmérsékleten tárolt útszelepet fokozatosan
kell szobahőmérsékletű helyre vinni, mielőtt nyomás alá
helyezik.
Az útszelepek csupán az adattáblán meghatározott műsza-
ki jellemzők tartományán belül használhatók. A berende-
zésen csak a gyártóval vagy annak képviselőjével történt
egyeztetés után hajthatók végre változtatások. Ezek a
mágneses útszelepek szűrt levegővel vagy semleges
gázzal használhatók. Ne lépje túl a szelep maximális
megengedett nyomását = 10 bar (illetve 8 bar piezotron
pilotszelep esetén – ATEX Ex ia). Vigyázat! A minimális
pilotnyomás 2 bar. A szelep telepítését és karbantartását
csak képzett szakember végezheti.
Szabványos, IP65 védettségű pneumatikus változatok,
illetve gázok, gőzök, ködök vagy porok miatt robbanásveszé-
lyes légkörben történő használatra való változatok, a 94/9/EK
ATEX irányelv szerint. (Ennek a változatnak a zónabesorolása
az ATEX adattáblán szerepel, E1 ref.).
Biztonsági előírások, 551-es széria: II 1GD c T6 T85 °C Ta
-40 – +65 °C
Biztonsági előírások, 553-es széria: II 2GD c T6 (T85 °C) -
T5 (T100 °C)
EC-típusvizsgálati tanúsítvány száma. (551-es széria):
INERIS 03 ATEX 0219 X
Az alapvető egészségvédelmi és biztonsági követelmények
teljesítését a következő európai szabványoknak való meg-
felelés biztosítja: EN 13463-1 és EN 13463-5.
Mágneses-pneumatikus változatok szolenoidokkal ellátva:
- IP65 védettség vagy tanúsítvány a robbanásveszélyes lég-
körben való használathoz a 94/9/EK ATEX irányelv szerint.
Szolenoiddal ellátott változatok ASCO szerelőlappal:
IP65 védettség alapváltozatban, vagy robbanásveszélyes
légkörben való használatra: II 3D IP65/IP67 vagy ATEX EEx
d, m, em, ia (551-es széria: II 1G/2D Ex ia IIC IP65/IP67
vagy 553-as széria: II 2G/D Ex ia IIC IP65/IP67).
Pilottal ellátott változatok CNOMO E06.05.80 (30-as méret)
vagy CNOMO E06.36.120N (15-ös méret) szerelőlappal:
IP 65 védettség alapváltozatban, vagy pilotok felszerelése
robbanásveszélyes légkörben való használatra az ATEX EEx
d vagy Ex ia előírásainak megfelelően.
Vigyázat (CNOMO pilotok): A zónabesorolást (ATEX
1999/927EK) elsősorban a szelepház adattábláján (10. és
20. ábra, E1 vagy E2 ref.) szereplő jelzések határozzák meg.
Biztonsági előírások a 94/9/EK ATEX irányelv értelmében: II
1GD c T6 T85 °C Ta -40 – +65 °C
EC-típusvizsgálati tanúsítvány száma:
INERIS 03 ATEX 0219 X
Ha ezt a terméket pilotra szereli az 94/9/EK ATEX irány-
elvnek megfelelően, a legkedvezőtlenebb kategóriát és
hőmérsékletet vegye gyelembe. Az alapvető egészség-
védelmi és biztonsági követelmények teljesítését a következő
európai szabványoknak való megfelelés biztosítja: EN 13463-1
és EN 13463-5. Be kell tartani a pilotszelepek szerelési hely-
zetét (a 4./5./14./15./21./22./23./24. ábrák szerint), valamint
a megadott meghúzási nyomatékokat.
A 94/9/EK ATEX irányelv teljesítése érdekében a
szolenoidok és pilotok esetében pontosan követni kell
a termékhez mellékelt megfelelő telepítési útmutatóban
foglalt utasításokat.
SZERELÉS
!
ATEX 94/9/EK változatok: Valamennyi fém és vezető
alkatrésznek mindig össze kell lenniük kapcsolva egy-
mással, és csatlakozniuk kell a földhöz. A szelepházat
rögzítőcsavarral kell csatlakoztatni a földhöz (F ref.).
A szelepek bármilyen helyzetben felszerelhetők.
Menetes nyílású változatok 1/4 (3a. ábra), 1/2 (3b. ábra):
A szelepet két csavarral kell felszerelni (1) (nincs mellékelve).
Változatok NAMUR felülettel (13a., 13b. ábra):
Az útszelepet be kell állítani a kívánt funkciónak megfelelően,
mielőtt felszerelnék a működtetőszervre:
- Válassza ki a kívánt funkciónak megfelelő illesztőlemezt:
3/2-es NC vagy 5/2-es (1a. vagy 1b.).
- Gondoskodjon a tömítés megfelelő elhelyezéséről (7).
- Szerelje az illesztőlemezt az útszelep alá a 2 mellékelt
csavarral (8), ügyelve a tájolásra. Fontos, hogy a funkció
jelzése a visszatérési oldalra kerüljön (polarizálónyílás).
- Helyezze fel a két tömítőgyűrűt (9).
Telepítési és karbantartási útmutató
3/2 NC
HU
551-es széria: mágnesszelepek, sárgaréz ház, vagy 551–553-as széria:
rozsdamentesacél ház, 1/4"-es, 1/2"-es menet vagy NAMUR felület
5/2
- Szükség esetén helyezze a polarizálótűt a működtetőszervre:
A Ø 5 polarizálónyílás a 3/2-es illesztőlemezen az A1-nél
található.
A Ø 5 polarizálónyílás a 5/2-es illesztőlemezen az A2-nél
található.
PNEUMATIKUS CSATLAKOZTATÁS
(3a., 3b., 13a. és 13b. ábra)
A változattól (3/2-es NC vagy 5/2-es) függően egy vagy
mindkét rozsdamentesacél kiáramlásvédő használható
(lásd a 2. ábrát).
• A pneumatikus pilotváltozat csatlakoztatása:
G 1/8 vagy NPT 1/8 vagy G 1/4 vagy NPT 1/4.
• A pilot kifúvónyílásainak csatlakoztatása
A kifúvott anyag a használt változatnak megfelelően gyűjt-
hető össze.
• Kézi vezérlés
A terméket, változattól függően, energiaellátás nélküli műkö-
dést lehetővé tévő kézi vezérléssel vagy a nélkül szállítjuk. A
kézi vezérlést a (
) szimbólum jelzi a 4., 5., 14., 15., 21–24.
ábrákon, valamint a 10-es pont a 3a., 3b., 13a., 13b. ábrákon.
Az impulzusos vagy folyamatos (gombnyomás/forgatás
jellegű) kézi vezérlést a ( ) ) szimbólum jelzi a 3a., 3b.,
13a. és 13b. ábrán; ez lehetővé teszi az energiaellátás
nélküli működést.
!
Üzembe helyezés előtt a személyi sérülés és a be-
rendezés sérülésének megelőzése érdekében győ-
ződjön meg róla, hogy a kézi vezérlés vissza van állít-
va kikapcsolt (0) helyzetbe.
Hozzáillesztés a külső pilotellátáshoz (3a., 3b., 13a. és
13b. ábra 6-os pont)
Általános ajánlások a pneumatikus csatlakoztatáshoz
A szelep mechanikai feszítésének megelőzése érdekében
megfelelően támassza alá és igazítsa be a csöveket. Meg-
húzáskor ne használja a szelepet feszítőkarként; a kulcsokat
a lehető legközelebb helyezze a csatlakozási ponthoz. NE
HÚZZA TÚL a csőcsatlakozásokat, mert megsérülhet a
berendezés.
Menetes nyílású változatok – 1/4-es (3a. ábra), 1/2-es
(3b. ábra):
Az útszelep csatlakoztatása:
Csatlakoztassa a csöveket a címkén jelzett módon:
- 3/2-es NC funkció:
Nyomásbemenet az 1. nyíláson (1/4”-es vagy 1/2”-es
menet) Nyomáskimenet a 2. nyíláson.
Kifúvás a 3. nyíláson (1/4”-es vagy 1/2”-es menet).
- 5/2-es funkció:
Nyomásbemenet az 1. nyíláson. Nyomáskimenet a 2. és
a 4. nyíláson.
A kifúvandó anyagot a szelep a 3. és az 5. nyíláshoz vezeti.
• Változatok NAMUR felülettel (13a., 13b. ábra):
Az útszelep csatlakoztatása:
Csatlakoztassa a csöveket a címkén jelzett módon:
- 3/2-es NC funkció:
Nyomásbemenet az 1. nyíláson (1/4”-es vagy 1/2”-es menet).
Nyomáskimenet a 2. nyíláson.
Kifúvás a 3. nyíláson.
(sárgaréz ház: 1/8 ; rozsdamentesacél ház: 1/4"-es vagy
1/2"-es menet)
Az egyszeres működésű m űködtetőszerv rugó-helyretolási
kamrájából a kifúvandó anyagot az útszelep a 3. nyíláshoz
vezeti. Javasolt az 5. nyílást védelemmel ellátni (ha nincs
használatban). Ne tömítse.
- 5/2-es funkció:
Nyomásbemenet az 1. nyíláson (1/4”-es vagy 1/2”-es
menet).
Nyomáskimenet a 2. és a 4. nyíláson.
A kifúvandó anyagot a szelep a 3. és az 5. nyíláshoz
vezeti.
(sárgaréz ház: 1/8 ; rozsdamentesacél ház: 1/4"-es vagy
1/2"-es menet)
Kifúvásreduktorok csatlakoztatása (sárgaréz ház)
Az 551-es útszelepeket a rendelés alapján miniatűr 1/8”-es
kifúvásreduktorral szállítjuk – M utótag (13a. ábra).
Az állítható mini kifúvásreduktorok a működtetőszerv üzemi
sebességének módosítására szolgálnak. Ezek a kifúvott
anyag összegyűjtése érdekében is csatlakoztathatók (1/8-
as menet).
Szerelés/beállítás (3a. ábra):
3/2-es NC változat = 1 kifúvásreduktort kell a 3. nyílásra
szerelni
5/2-es változat = 2 kifúfásreduktort kell felszerelni, a 3. és
az 5. nyílásra
Illessze a reduktor csavarját (4) a furatba, és csavarja be
ütközésig; majd a kifúvás áramának erősítéséhez csavarja
kifelé (két fordulatnál ne többet; a max. áramlás egy
fordulattal elérhető).
Szorítsa meg a rögzítőanyát (4a) 13 mm-es kulccsal.
A nyomás alá helyezés előtt végezzen durvabeállítást, majd
nyomás alatt nombeállítást.
ELEKTROMOS CSATLAKOZTATÁS
Szolenoiddal ellátott változatok ASCO felülettel: tekintse
meg az egyes szolenoidok gyártói által mellékelt telepítési
útmutatókat is.
IP65 védettségű szolenoid (3a., 3b. és 13a., 13b. ábra):
szerelje a tekercset a csőre (360°-ban elforgatható), majd
a levehető ISO 4400/EN 175101-803A csatlakozót (6–10
mm-es kábelátmérő), mely 90°-ban elforgatható (3 érint-
kező: 2 + föld).
CNOMO szerelőlappal ellátott változatok: tekintse meg
az egyes pilotszelepek gyártói által mellékelt telepítési útmu-
tatókat is.
• Általános ajánlások:
Az elektromos csatlakoztatást képzett szakembernek kell
végrehajtania, a vonatkozó helyi szabványoknak és elő-
írásoknak megfelelően.
Fontos:
- Bármilyen munka megkezdése elő
tt le kell kapcsolni az
áramellátást a komponensek áramtalanítása érdekében.
- Az elektromos komponenseket a feszültségtől függően
földelni kell, a helyi szabványoknak és előírásoknak
megfelelően.
A legtöbb szelep tartós terheléshez készült tekercsekkel
rendelkezik. A személyi sérülés kockázaténak elkerülése
érdekében ne érjen a szolenoidhoz, mivel az normál üzemi
körülmények között felforrósodhat. Ha a szelep könnyen
megközelíthető helyen van, a szerelőnek a szolenoidot el
kell látnia a véletlen érintés megakadályozását szolgáló
védelemmel.
KARBANTARTÁS
!
Bármilyen karbantartási munka vagy üzembe helyezés
előtt a személyi sérülés és a berendezés sérülésének
megelőzése érdekében kapcsolja le a szelep energiaellá-
tását, nyomásmentesítse és eressze le a szelepet.
ATEX-változatok: pontosan kövesse a 99/92/EK irányelv
és a kapcsolódó szabványok által ajánlott eljárásokat.
• Tisztítás
A szelepek karbantartása az üzemi feltételektől függ.
Rendszeres időközönként meg kell őket tisztítani. Szer-
vizeléskor ellenőrizni kell, nem koptak-e el az egyes
komponensek. Ezek tisztítást igényelnek, ha a ciklus
lelassult, még akkor is, ha a pilotnyomás megfelelő, és
nem észlelhető semmilyen szokatlan zaj vagy szivárgás.
Zajkibocsátás
A zajszint pontos meghatározását csak a szeleppel fel-
szerelt rendszer felhasználója tudja elvégezni. A kibocsá-
tott zaj függ az alkalmazástól, a közegtől és a használt
berendezés típusától.
Megelőző karbantartás
- Működésének vizsgálatához használja a szelepet leg-
alább egy
hónapig.
- Ha a karbantartás közben probléma merül fel, vagy
kérdés esetén
forduljon hozzánk vagy valamelyik hivatalos képvisele-
tünkhöz.
Hibaelhárítás
- Nem megfelelő kilépőnyomás: ellenőrizze a nyomást
a szelep ellátási oldalán; ennek meg kell felelnie az
adattáblán szereplő értékeknek.
Vigyázat! A minimális pilotnyomás 2 bar.
Az újbóli üzembe állítás előtt a személyi sérülés és a be-
rendezés sérülésének megelőzése érdekében ellenőrizze,
megfelelően működik-e a szelep.
Pótalkatrészek
Tekercsek rendelhetők pótalkatrészként.
Szükség esetén az egész szelepet ki kell cserélni.
33
32
3834901
3834901
5/2
3/2 NC/NL/NF
g. 1
CONNECTION
GB
RACCORDEMENT
FR
ANSCHLUSS
DE
RACORDAJE
ES
COLLEGAMENTO
IT
AANSLUITING
NL
TILKOBLING
NO
ANSLUTNING
SE
TOIMINNAN
FI
TILSLUGNING
DK
LIGAÇÃO
PT
ÓÕÍÄÅÓÇ ÁÍÁËÏÃÁ ÌÅ ÔÇ
GR
PŘIPOJENÍ
CZ
PODŁĄCZENIE
PL
CSATLAKOZTATÁS
HU
g. 2
3 - 4
195
BP17 28111 LUCE FRANCE
Tamb.
R
R
E2
g.22
g.21
g.5
g.4
34600484 (M5)
34600418 (G1/8) 34600482 (NPT1/8)
34600419 (G1/4) 34600483 (NPT1/4)
a 10 ± 2 88 ± 18
b 2 ± 2 18 ± 18
Rep. N.m Inch.Pounds
F
E2
g.10
630
E2E1
b
E2E1
b
YEAR
INERIS 03 ATEX0219X
T. am b.
SERIAL No
PIPE
bar
T.P.L
CATALOGUE N˚
MEDIUM
T
T ˚C
BP17 28111 LUCE FRANCE
II1GD c
0081
E1
suitable
Threaded versions / Versions taraudées / Gewindeausführungen / Versiones roscadas /
Versioni fi lettate / Getapte versies / Gjengede versjoner / Utföranden med gänga /
Kierreversiot / Gevind versioner / Versões com rosca / Εκδόσεις με σπείρωμα
Verze se závitem / Wersje gwintowane / Menetes változatok
2
3
1212
1
2
3
5
14
4
12
1
14
2
3
12
1
10 10
12
551
(1/4)
g. 3a
90
1
2
F
a
3
8
a
10
6
1
90
1
2
F
a
a
3
a
10
6
1
F
1
F
1
0
10
1
2
YEAR
II2GD c
T. amb.
SERIAL No
PIPE
bar
T.P.L
CATALOGUE N°
MEDIUM
T
T °C
BP17 28111 LUCE FRANCE
11,5 mm
1/4
551
5/2-5/3
3/2 NC/NL/NF
g. 1
CONNECTION
GB
RACCORDEMENT
FR
ANSCHLUSS
DE
RACORDAJE
ES
COLLEGAMENTO
IT
AANSLUITING
NL
TILKOBLING
NO
ANSLUTNING
SE
TOIMINNAN
FI
TILSLUGNING
DK
LIGAÇÃO
PT
ÓÕÍÄÅÓÇ ÁÍÁËÏÃÁ ÌÅ ÔÇ
GR
PŘIPOJENÍ
CZ
PODŁĄCZENIE
PL
CSATLAKOZTATÁS
HU
g. 2
34600418 (G1/8) 34600482 (NPT1/8)
34600479 (G1/2) 34600481 (NPT1/2)
a 10 ± 2 88 ± 18
b 2 ± 2 18 ± 18
Rep. N.m Inch.Pounds
F
553
(1/2)
E2
g.10
YEAR
INERIS 03 ATEX0219X
T. amb.
SERIAL No
PIPE
bar
T.P.L
CATALOGUE N˚
MEDIUM
T
T ˚C
BP17 28111 LUCE FRANCE
II1GD c
0081
E1
Threaded versions / Versions taraudées / Gewindeausführungen
/ Versiones roscadas /
Versioni fi lettate / Getapte versies / Gjengede versjoner / Utföranden med gänga /
Kierreversiot / Gevind versioner / Versões com rosca / Εκδόσεις με σπείρωμα
2
3
1212
1
2
3
5
14
4
12
1
14
2
3
12
1
10 10
12
g. 3b
F
Stainless steel - Acier inox
Edelstahl - Acero inoxidable
Acciaio inox - Roestvast staal
rustfritt - rostfri
ruostumatonta - rustfri
Aço inoxidável - από ορείχαλκο
1
F
1
F
90
1
2
a
3
a
1
0
6
1
F
1
0
90
1
2
F
a
a
3
a
6
1
3 - 4
0
10
1
2
YEAR
II2GD c
T. amb.
SERIAL No
PIPE
bar
T.P.L
CATALOGUE N°
MEDIUM
T
T °C
BP17 28111 LUCE FRANCE
24
3
5
14
12
1
24
3
5
14
12
1
35
34
3834901
5/2
3/2 NC/NL/NF
g. 11
CONNECTION
GB
RACCORDEMENT
FR
ANSCHLUSS
DE
RACORDAJE
ES
COLLEGAMENTO
IT
AANSLUITING
NL
TILKOBLING
NO
ANSLUTNING
SE
TOIMINNAN
FI
TILSLUGNING
DK
LIGAÇÃO
PT
ÓÕÍÄÅÓÇ ÁÍÁËÏÃÁ ÌÅ ÔÇ
GR
PŘIPOJENÍ
CZ
PODŁĄCZENIE
PL
CSATLAKOZTATÁS
HU
g. 2
3 - 4
g.24
g.23
34600484 (M5)
34600418 (G1/8) 34600482 (NPT1/8)
a 10 ± 2 88 ± 18
b 2 ± 2 18 ± 18
Rep. N.m Inch.Pounds
F
551
(1/4)
E2
g.20
630
E2E1
b
E2E1
b
YEAR
INERIS 03 ATEX0219X
T. am b.
SERIAL No
PIPE
bar
T.P.L
CATALOGUE N˚
MEDIUM
T
T ˚C
BP17 28111 LUCE FRANCE
II1GD c
0081
E1
suitable
NAMUR versions / Versions NAMUR / NAMUR-Ausführungen / Versiones NAMUR /
versioni NAMUR / NAMUR-versies / NAMUR-versjoner / NAMUR-utföranden /
NAMUR-versiot / NAMUR versioner / Versões NAMUR / Εκδόσεις NAMUR
Verze s rozhraním NAMUR / Wersje NAMUR / NAMUR-változatok
F
0
10
1
2
g. 13a
3
3
5
Brass - Laiton
Messing - Latón
Ottone - Koperen
hus - kropp
Runko - hus
Latão - Ïñåß÷áëêïò
Mosaz
-
Brąz
-
sárgaréz
551
8
G1/8
F
1
5
3 / 2
3 / 2
1a
A1
3 / 2
3 / 2
7
9
a
4
4
a
a
2
3
2
4
3
90°
5
1
2
3 / 23 / 2
551
1
1a
2
A
1
3 / 23 / 2
7
9
5
8
F
a
a
10
6
2
4
a
4
4
a
3
551
8
G1/8
F
1
5
5 / 25 / 2
1b
5 / 25 / 2
A
2
7
9
a
2
a
3
4
4
a
2
4
3
9
0
°
5
1
2
551
1
5
2
5 / 25 / 2
1b
5 / 25 / 2
A2
7
9
8
F
8
a
10
6
2
4
a
3
4
4
a
3
4
3
1
2
5
12
4
5
3
12
2
1
4
12
2
3
1
5
YEAR
II2GD c
T. amb.
SERIAL No
PIPE
bar
T.P.L
CATALOGUE N°
MEDIUM
T
T °C
BP17 28111 LUCE FRANCE
5/2
3/2 NC/NL/NF
g. 11
CONNECTION
GB
RACCORDEMENT
FR
ANSCHLUSS
DE
RACORDAJE
ES
COLLEGAMENTO
IT
AANSLUITING
NL
TILKOBLING
NO
ANSLUTNING
SE
TOIMINNAN
FI
TILSLUGNING
DK
LIGAÇÃO
PT
ÓÕÍÄÅÓÇ ÁÍÁËÏÃÁ ÌÅ ÔÇ
GR
PŘIPOJENÍ
CZ
PODŁĄCZENIE
PL
CSATLAKOZTATÁS
HU
g. 2
3 - 4
195
BP17 28111 LUCE FRANCE
Tamb.
R
R
E2
g.15 (551)
g.14 (551)
34600418 (G1/8) 34600482 (NPT1/8)
34600419 (G1/4) 34600483 (NPT1/4)
34600479 (G1/2) 34600481 (NPT1/2)
a 10 ± 2 88 ± 18
b 2 ± 2 18 ± 18
Rep. N.m Inch.Pounds
F
551 - 553
YEAR
II2GD c
T. amb.
SERIAL No
PIPE
bar
T.P.L
CATALOGUE N°
MEDIUM
T
T °C
BP17 28111 LUCE FRANCE
E2
g.20
YEAR
INERIS 03 ATEX0219X
T. amb.
SERIAL No
PIPE
bar
T.P.L
CATALOGUE N˚
MEDIUM
T
T ˚C
BP17 28111 LUCE FRANCE
II1GD c
0081
E1
suitable
NAMUR versions / Versions NAMUR / NAMUR-Ausführungen / Versiones NAMUR /
versioni NAMUR / NAMUR-versies / NAMUR-versjoner / NAMUR-utföranden /
NAMUR-versiot / NAMUR versioner / Versões NAMUR / Εκδόσεις NAMUR
Verze s rozhraním NAMUR / Wersje NAMUR / NAMUR-változatok
F
0
10
1
2
4
3
1
2
5
12
4
5
3
12
2
1
4
12
2
3
1
5
g. 13b
3
90
5
1
2
551
1
5
2
5 / 25 / 2
1b
5 / 25 / 2
A2
7
9
F
a
a
10
6
2
4
3 x 1/4
551
8
G1/8
F
5 / 2
5 / 2
1b
5 / 2
5 / 2
A2
7
9
2
3
3
1
5
2
4
3 x 1/4
551
8
G1/8
F
3 / 23 / 2
1a
A1
3 / 23 / 2
7
9
2
3
3
1
5
a
2
4
3 x 1/4
90
5
1
2
3 / 23 / 2
551
1a
2
A1
3 / 23 / 2
7
9
F
a
10
6
3
1
5
a
2
4
3 x 1/4
3
3
5
Stainless steel - Acier inox
Edelstahl - Acero inoxidable
Acciaio inox - Roestvast staal
rustfritt - rostfri
ruostumatonta - rustfri
Aço inoxidável - από ορείχαλκο
Nerezavějící ocel
-
Stal nierdzewna
-
rozsdamentes acél
(551)
ASCO JOUCOMATIC SA
32 Av. Albert 1
er
- BP 312 - 92506 RUEIL Cedex - France
Tel. (33) 147.14.32.00 - Fax (33) 147.08.53.85 - http://www.asconumatics.eu
36 37
3834901 3834901

Transcripción de documentos

Installation and Maintenance Instructions Series 551 solenoid valves, brass body, or series 551-553, stainless steel body, 1/4“, 1/2" thread or NAMUR interface DESCRIPTION OF THE APPROVAL Versions concerned by the approval (fig. 1 and 11): Brass body (series 551) or stainless steel body (series 551, 553), monostable (spring return) or bistable, 3/2 NC (normally closed) function or 5/2, version isolated from the outside atmosphere. Versions with or without manual override. - with threaded 1/4 (551) or 1/2 (553) ports - 551, with ¼” threaded connection, max. port depth 11,5 mm. - (Do not connect the pressure supply to the exhaust port 3. The “environmentally-protected” construction is not adapted for a “distributing” function or use in NO function. Contact us for functions available in specific versions). - with NAMUR interface for direct mounting to single acting (function 3/2 NC) or double acting (function 5/2) pneumatic actuators. The function of the valve is convertible from 3/2 NC to 5/2 by mounting the supplied 3/2 NC or 5/2 interface plate at the bottom of the valve (fig.13a, 13b, ref. 1a and 1b). 551, max. 1/4" port depth = 11,5 mm. (Do not connect the pressure supply to the exhaust port 3.The “environmentallyprotected” construction is not adapted for NO function. Contact us for functions available in specific versions). Connect pipes for the required functions in accordance with this documentation and the port markings on the product. - Make sure no foreign matter enters the circuit to prevent blocking the valve function. Restrict the use of sealing tape or sealing matter to a minimum. - These valves are intended for use with clean and dry air or inert gas. Recommended minimum filtration: 50 microns. The dew point of the fluid used must be at least –10°C (18°F) below the minimum temperature to which the fluid may be exposed. When using lubricated air, the lubricant must be compatible with the elastomers used. Instrument air in compliance with ANSI/ISA standard S7.3 (1975) exceeds the necessary requirements and is, therefore, an acceptable fluid for these valves. 3/2 NC 5/2 - 5/3 Installation and Maintenance Instructions GB Series 551 solenoid valves, brass body, or series 551-553, stainless steel body, 1/4“, 1/2" thread or NAMUR interface PNEUMATIC CONNECTION (fig. 3a, 3b, 13a and 13b) Depending on the version (3/2 NC or 5/2), one or both stainless steel exhaust protectors can be used (see fig. 2). cal characteristics specified on the nameplate. Changes to the equipment are only allowed after consulting the manufacturer or its representative. These solenoid spool valves are designed to operate with filtered air or neutral gas. Do not exceed the maximum allowable pressure of the valve = 10 bar (or 8 bar with a Piezotronic pilot valve to ATEX Ex ia). Caution: Observe the minimum pilot pressure of 2 bar. Installation and maintenance of the valve must be carried out by qualified personnel only. • Manual override Depending on the version, the products are supplied with or without manual override for operation without power. The manual override is indicated with the symbol ( ) on fig. 4, 5, 14, 15, 21 to 24, and ref. 10 on fig. 3a, 3b, 13a, 13b. The impulse-type or maintained (push/turn type) manual override indicated by the symbol ( ) on fig. 3a, 3b, 13a and 13b allows operation without power. • • Versions with solenoid operators with ASCO mounting pad, IP65-rated as standard, or for use in explosive atmospheres II 3D IP65/IP67 or ATEX Ex d, m, em, Ex ia (Series 551: II 1G/2D Ex ia IIC IP65/IP67 or series 553: II 2G/D Ex ia IIC IP65/IP67). 2 3834901 Availability, design and specifications are subject to change without notice. All rights reserved. • 3834901-A (A = R1) • Versions with pilots with CNOMO E06.05.80 (size 30) or CNOMO E06.36.120N (size 15) mounting pad, IP 65-rated as standard, or mounting of pilots for use in explosive atmospheres according to ATEX Ex d or Ex ia. All exhaust ports of the valves and pilots must be Caution (CNOMO pilots): The zone classification ! protected with the stainless steel exhaust protectors. (ATEX 1999/927EC) is mainly defined by the indicaConnect these exhaust protectors to port 3 (3/2 NC) tions on the nameplate fig. 10 and 20 (ref. E1 or E2) or ports 3 – 5 (5/2) of the valves. When used outside, or on the valve’s body. Safety code according to ATEX stored for longer periods of time, and/or where exposed Directive 94/9/EC: II 1 GD c T6 T85°C Ta -40°C to +65°C to harsh environments (dusts, liquids etc.), exhaust proEC type-examination certificate no.: INERIS 03 ATEX 0219 X tectors must be used. The reliability of the valve cannot When assembling this product to a pilot to ATEX 94/9/EC, be guaranteed if an exhaust protection other than that take the least favourable category and temperature into supplied is used. account. Compliance with the Essential Health and Safety Requirements has been assured by compliance with the Eu- Allowable temperature range: ropean Standards EN 13463-1 and EN 13463-5.The mounting -40°C to +80°C (series 551); -40°C to +60°C (series 553). position for the pilots as shown in figures 4/5/14/15/21/22/23/24 - Max. operating pressure range: and the indicated tightening torques must be observed. -2 to 10 bar For solenoid operators and pilots to ATEX 94/9/EC, the -2 to 8 bar (ISSC/PISC/PISCIS/CFSCIS/CFSDISCFVTIS) instructions for use given in the specific Installation Instructions provided with the product must be strictly followed. GENERAL DESCRIPTION ATEX 94/9/EC versions: See “Special conditions for safe use”. ASSEMBLY ! ATEX 94/9/EC versions: Make sure that all metal or Versions isolated from atmosphere: The internal parts of conductive parts are always interconnected and conthe valve are isolated from the outside atmosphere in order to provide protection in aggressive environments. All the exhaust nected to earth. The valve body is connected to earth with the ports of the spool valve are pipable, providing better environ- fastening screw (ref. F). mental protection, particularly recommended for sensitive areas The valves may be mounted in any position. such as clean rooms and applications in the pharmaceutical or food processing industries. It is necessary to connect pipes or Threaded port versions 1/4 (fig 3a), 1/2 (fig 3b): fittings to the exhaust ports to protect the internal parts of the Mount the valve with two screws (ref. 1) (not supplied). spool valve if used outside or in harsh environments (dusts, liquids etc.). Versions with NAMUR interface (fig. 13a, 13b): Before mounting the spool valve on the actuator, it must be SPECIAL CONDITIONS FOR SAFE USE set to the required function: ATEX 94/9/EC: The valve must be connected to ground (see - Select the interface plate with corresponds to the required "Assembly"). function: 3/2 NC or 5/2 (ref. 1a or 1b). The maximum fluid temperature must not exceed the ambient - Make sure the seal is properly seated (ref. 7). temperature. - Mount the interface plate under the spool valve with the 2 The spool valve must be kept in its original packaging as long supplied screws (ref. 8) and observe the mounting direction. as it is left unused. The protective covers must not be removed Make sure the indication of the function is placed on the from the connection ports and solenoid operators. return side (polarising slot). Storage conditions: protected from exposure to weather; storage - Fit the two O-rings (ref. 9). temperature: -40 C to +70°C ; relative humidity: 95 % - Place the polarising pin on the actuator if necessary: After storage at low temperature, the spool valves must The polarising slot Ø 5 on the 3/2 interface plate is at A1. gradually be brought to room temperature prior to presThe polarising slot Ø 5 on the 5/2 interface plate is at A2. surisation. The spool valves are intended to be operated within the techni- ELECTRICAL CONNECTION • Version with solenoid operators with ASCO interface: See additional installation instructions supplied with every solenoid operator. IP65-rated solenoid operator (fig. 3a, 3b and 13a, 13b): Mount the coil on the tube (rotatable through 360°) and then the removable ISO 4400/EN 175101-803A connector (cable dia 6-10 mm) rotatable by 90° (3 pins: 2 + earth). • Connection of pilot exhausts The exhausts can be collected according to the version used. • Solenoid-air operated versions fitted with solenoid operators: - IP65-rated or certified for use in explosive atmospheres according to ATEX Directive 94/9/EC. • • GB Make rough adjustment before pressurisation and fine-tune after pressurisation. • Connection of pneumatic pilot version: G 1/8 or NPT 1/8 or G 1/4 or NPT 1/4. • Standard IP65-rated air operated versions or versions for use in explosive atmospheres caused by gases, vapours, mists or dusts according to ATEX Directive 94/9/EC. (The zone classification for this version is stated on the ATEX nameplate, ref. E1). Safety code, series 551: II 1 GD c T6 T85°C Ta -40°C to +65°C Safety code, series 553: II 2 GD c T6 (T85°C) - T5 (T100°C) EC type-examination certificate no. (Series 551): INERIS 03 ATEX 0219 X Compliance with the Essential Health and Safety Requirements has been assured by compliance with the European Standards EN 13463-1 and EN 13463-5. 3/2 NC 5/2 - 5/3 • Version with CNOMO pad mounting: See additional installation instructions supplied with every pilot valve. • General recommendations: Electrical connections must be made by qualified personnel and according to applicable local standards and regulations. Please note: ! Prior to any putting into operation, make sure the - Before starting any work, turn off the electrical current to manual override is returned to its disengage position power off the components. - Depending on the voltage, electrical components must be “0” to prevent the risk of personal injury or damage to grounded according to local standards and regulations. equipment. Most valves are equipped with coils designed for continuous Adaption to external pilot supply (fig.3a, 3b, 13a et 13b, duty. To prevent the risk of personal injury, do not touch the ref. 6) solenoid operator which can become hot under normal operating conditions. If the valve is easily accessible, the installer General recommendations for pneumatic connection must provide for protection against accidental contact of the Correctly support and align the pipes to prevent mechanical solenoid operator. strain on the valve. When tightening, do not use the valve MAINTENANCE ! Prior to any maintenance work or putting into operation, as a lever; locate wrenches as close as possible to connection point. To avoid damage to the equipment, DO NOT power off, depressurise and vent the valve to prevent OVERTIGHTEN pipe connections. the risk of personal injury or damage to equipment. ATEX versions: Strictly follow all procedures recommended Threaded 1/4 (fig 3a), 1/2 (fig 3b) port versions: by Directive 99/92/EC and associated standards. Connection of the spool valve: • Cleaning Connect pipes as indicated on the label: - 3/2 NC function: Maintenance of the valves depends on the operating conPressure inlet at port 1 (1/4” or 1/2” thread). Pressure outlet ditions. They must be cleaned at regular intervals. During servicing, the components must be checked for excessive at port 2. Exhaust at port 3 (1/4” or 1/2” thread). wear. The components must be cleaned when a slowing - 5/2 function: Pressure inlet at port 1. Pressure outlet at ports 2 and 4. down of the cycle is noticed even though the pilot pressure The exhausts are channelled through the valve to ports 3 and is correct or if any unusual noise or a leak is detected. 5. • Sound emission Versions with NAMUR interface (fig. 13a, 13b): The exact determination of the sound level can only be carConnection of the spool valve: ried out by the user having the valve installed in his system. Connect pipes as indicated on the label: The emission of sound depends on the application, fluid and type of equipment used. - 3/2 NC function: Pressure inlet at port 1 (1/4” or 1/2” thread). Pressure outlet • Preventive maintenance at port 2. Exhaust at port 3. (brass body: 1/8 ; stainless steel - Operate the valve at least once a month to check its funcbody: 1/4" or 1/2" thread). tion. - If problems arise during maintenance or in case of doubt, Exhaust from the return spring chambers of the single actplease contact us or one of our authorised representatives. ing actuator is channelled through the spool valve to port 3. It is recommended to protect port 5 (if not used). Do not seal it. • Troubleshooting - Incorrect outlet pressure: Check the pressure on the supply - 5/2 function: side of the valve; it must correspond to the values indicated on the nameplate. Pressure inlet at port 1 (1/4” or 1/2” thread). Caution: observe the minimum pilot pressure value 2 bar. Pressure outlet at ports 2 and 4. The exhausts are channelled through the valve to ports 3 To avoid personal injury or damage to equipment, check that and 5 (brass body: 1/8 ; stainless steel body: 1/4" or 1/2" the valve operates correctly before putting it back into operation. thread). • Spare parts Coils are available as spare parts. Connection of exhaust reducers (brass body) Series 551 spool valves are supplied as ordered with or If necessary, replace the entire valve. without miniature 1/8” exhaust reducers, suffix M (fig. 13a). These adjustable mini exhaust reducers are used to adjust the actuator’s operating speed. They can also be connected (1/8 thread) to collect the exhausts. Assembly / Adjustment (fig. 3a): Version 3/2 NC = 1 exhaust reducer to be fitted to port 3 Version 5/2 = 2 exhaust reducers to be fitted to ports 3 and 5 Engage the screw (4) on the reducer into the hole and screw it in until it stops; next turn it out to increase the exhaust flow (never more than two turns, max. flow obtained at one turn). Tighten the locknut (4a) with a 13 mm wrench. 3 3834901 Instructions de mise en service et d'entretien Distributeurs Série 551, corps laiton ou Séries 551-553, corps acier inox taraudé 1/4, 1/2 ou à plan de pose NAMUR DESCRIPTION DE LA CERTIFICATION Versions concernées par cette mise en service (fig 1 et 11) : Corps laiton (Série 551) ou acier inox (Séries 551, 553), monostable (rappel ressort) ou bistable, version 3/2 NF (normalement fermée) ou 5/2, versions étanches par rapport à l'atmosphère. Versions sans ou avec commande manuelle : - à raccordement taraudé 1/4 (551) ou 1/2 (553) - 551, profondeur maxi des orifices de raccordement 11,5 mm (Ne pas raccorder l’alimentation de pression à l’orifice 3 d’échappement. La construction “étanche à l’atmosphère” n’est pas adaptée pour la fonction “distributrice” et une utilisation en fonction NO. Fonctions disponibles en version spécifique, nous consulter). - à plan de pose suivant recommandation type NAMUR pour adaptation directe sur actionneur pneumatique simple effet (fonction 3/2 NF) ou double effet (fonction 5/2). Un même distributeur s'adapte aux deux types de commande par mise en place à la partie inférieure de l'une des deux plaques interface 3/2 NF ou 5/2 fournies (fig. 13a, 13b, rep. 1a et 1b). 551, 1/4, profondeur maxi des orifices de raccordement 1/4 = 11,5 mm (Ne pas raccorder l’alimentation de pression à l’orifice 3 d’échappement. La construction “étanche à l’atmosphère” n’est pas adaptée pour la fonction NO. Fonctions disponibles en version spécifique, nous consulter). - Raccorder les tuyauteries suivant les fonctions souhaitées en tenant compte des repères d'orifices marqués sur le produit et dans cette documentation. - Veiller à ce qu’aucun corps étranger ne pénètre dans le circuit afin d'éviter tout blocage de la vanne. Limiter l'utilisation de ruban ou pate d'étanchéité. - Ces distributeurs et électrodistributeurs doivent être utilisés que sur air, propre et sec, ou un gaz neutre. Filtration minimale recommandée 50 microns. Le point de rosé du fluide utilisé doit être au minimum de -10°C (18°F) en dessous de la température minimale à laquelle le fluide peut être soumis. En cas d'utilisation d'air lubrifié, le lubrifiant doit être compatible avec les élastomères utilisés. La qualité "air instrument" définie par la norme ANSI/ ISA S7.3 (1975) est supérieure aux exigences requises et constitue de fait, un "media" acceptable pour ces vannes. 3/2 NF 5/2 - 5/3 distributeur doit rester dans son emballage d'origine. Les éléments de protection des orifices de raccordement et des têtes magnétiques doivent rester en place. Conditions de stockage : à l'abri des intempéries; température : - 40°C à +70°C; humidité relative : 95 % Après stockage à basse température, les distributeurs doivent être remis progressivement à la température ambiante de fonctionnement avant la première mise sous pression. Les distributeurs sont conçus pour les domaines de fonctionnement indiqués sur la plaque signalétique. Aucune modification ne peut être réalisée sur le matériel sans l’accord préalable du fabricant ou de son représentant. Ces distributeurs sont prévus pour fonctionner sur air ou gaz neutres filtrés. Ne pas dépasser la pression maximale admissible = 10 bar (ou 8 bar avec pilote piézotronic/302/195 ATEX Ex ia). Respecter la valeur minimale de pression de pilotage de 2 bar. La mise en service et l'entretien de ces produits doivent être réalisés par un personnel compétent. • Versions à commande pneumatique standard IP65 ou prévues pour atmosphères explosibles sous forme de gaz, vapeurs, brouillards et poussières selon la directive ATEX 94/9/CE. (Le classement en zone de cette version est définie par l'étiquette ATEX, rep.E1). Mode de protection, série 551 : II 1 GD c T6 T85°C Ta -40°C à +65°C Mode de protection, série 553 : II 2 GD c T6 (T85°C) - T5 (T100°C) Attestation d'examen CE de type (séries 551) : INERIS 03 ATEX 0219 X Le respect des exigences essentielles en ce qui concerne la sécurité et la santé est assuré par la conformité aux normes européennes EN 13463-1 et EN 13463-5. • Versions à commande électropneumatique équipées de têtes magnétiques : - étanches IP65 ou certifiées pour atmosphères explosibles selon la Directive ATEX 94/9/CE - Versions têtes magnétiques selon plan de pose ASCO, standard IP65 ou pour atmosphères explosibles, II 3D IP65/ IP67 ou ATEX Ex d, m, em, Ex ia (série 551 : II 1G/2D Ex ia IIC IP65/IP67 ou série 553 : II 2G/D Ex ia IIC IP65/ IP67). - Versions à pilotes, selon plan de pose CNOMO E06.05.80 (taille 30) ou CNOMO E06.36.120N (taille 15), standard Protéger les orifices d'échappement des distribuIP 65 ou montage de pilotes pour atmosphères explosibles teurs et des pilotes au moyen des protecteurs d'échapATEX, Ex d ou Ex ia. pement en acier inox. Pour le distributeur, raccorder ces Attention (pilotes CNOMO) : Le placement en zones (ATEX protecteurs au port 3 (3/2 NF) ou aux ports 3 - 5 (5/2). En 1999/92/CE), est défini prioritairement par le marquage ambiance extérieure, stockage prolongé, et/ou en pré- indiqué sur l'étiquette fig.10 et 20 (rep. E1 ou E2) placée sence de poussières, liquides et agents présents dans sur le corps du distributeur. Mode de protection, selon l'environnement, la présence de protecteurs d'échappe- ATEX 94/9/CE : II 1GD c T6 T85°C Ta -40°C à +65°C. ment est impérative. La fiabilité de la vanne ne sera pas Attestation d'examen CE de type : INERIS 03 ATEX 0219 X garantie en cas d'utilisation d'un moyen de protection des échappements différent que ceux préconisés. Prendre en compte la catégorie, les pressions de fonc- Plage de température autorisée : tionnement et la température la moins favorable lors d'un -40°C à +80°C série 551 ; -40°C à +60°C série 553 assemblage avec un pilote ATEX 94/9/CE. Le respect des - Plage de pression maximale de fonctionnement : exigences essentielles en ce qui concerne la sécurité et la - 2 à 10 bar santé est assuré par la conformité aux normes européennes - 2 à 8 bar (ISSC/PISC/PISCIS/CFSCIS/CFSDIS/CFVTIS) EN 13463-1 et EN 13463-5. Respecter le sens de montage des pilotes indiqué par les figures 4/5/14/15/21/22/23/24 et DESCRIPTION GENERALE les couples de serrage indiqués. Versions ATEX 94/9/CE : Voir "conditions spéciales pour Pour les têtes magnétiques et pilotes ATEX 94/9/CE, suivre une utilisation sûre". impérativement les prescriptions d'utilisation décrites Versions étanches par rapport à l'atmosphère : Les com- dans chaque notice de mise en service spécifique fournie posants internes du distributeur sont isolés de l'atmosphère avec le produit. extérieure, le protégeant ainsi de tout environnement agressif. MONTAGE Tous les orifices d'échappements étant canalisables, ils assu! Versions ATEX 94/9/CE : S'assurer que toutes les parties rent une meilleure protection de l'environnement, particulièrement recommandée pour les installations en zones sensibles métalliques ou conductrices soient toujours interconnectées et telles que salles blanches, industries pharmaceutiques ou reliées à la terre. La liaison à la terre du corps de distributeur agro-alimentaires. Il est nécessaire de canaliser ou d'équiper se fait par montage de la vis de fixation (rep. F). les échappements pour protéger les composants internes Les distributeurs peuvent être montés dans n'importe quelle du distributeur dans le cas d'utilisation à l'extérieur ou en position. environnement difficile (poussières, liquides ou autres agents). Versions taraudés 1/4 (fig. 3a) 1/2 (fig. 3b) : Monter le distributeur à l'aide de deux vis (rep.1), non fournies. CONDITIONS SPECIALES POUR UNE UTILISATION SURE Versions à plan de pose NAMUR (fig. 13a, 13b) : ATEX 94/9/CE : Le distributeur doit être relié à la terre (VoirMontage). Avant montage du distributeur sur l'actionneur, adapter l'apLa température maximale du fluide ne doit pas excéder la pareil à la fonction souhaitée : température ambiante. - Sélectionner la plaque interface correspondant à la fonction En cas de stockage prolongé avant mise en service, le nécessaire 3/2 NF ou 5/2 (rep.1a ou 1b). ! 4 Instructions de mise en service et d'entretien Distributeurs Série 551, corps laiton ou Séries 551-553, corps acier inox taraudé 1/4, 1/2 ou à plan de pose NAMUR FR 3834901 - S'assurer de la présence et de la mise en place correcte du joint de forme (rep.7). - Assembler la plaque sous le distributeur à l'aide des 2 vis (rep.8) fournies, en respectant le sens de montage : le repère de fonction doit être placé coté rappel (détrompeur). - Monter les deux joints toriques (rep.9). - Placer, si nécessaire, le pion de détrompage sur l'actionneur: • Sur la plaque 3/2, le trou de détrompage Ø 5 se situe en A1. • Sur la plaque 5/2, le trou de détrompage Ø 5 se situe en A2. 3/2 NF 5/2 - 5/3 FR d'adapter la vitesse de manoeuvre de l'actionneur. Ils sont également raccordables (filetage 1/8) pour collecter les échappements. Montage / Réglage (fig. 13a) : Version 3/2 NF = 1 réducteur à adapter sur l'orifice 3 Version 5/2 = 2 réducteurs à adapter sur les orifices 3 et 5 Serrer dans l'orifice la vis (4) du réducteur jusqu'en butée, puis dévisser pour augmenter le débit d'échappement sans jamais dépasser 2 tours (débit maxi obtenu à partir d'1 tour). Bloquer le contre-écrou (4a) avec une clé plate de 13 mm. Le réglage doit s'effectuer hors pression, il est à affiner lors des essais sous pression. RACCORDEMENT PNEUMATIQUE (fig. 3a, 3b,13a et 13b) Selon la version 3/2 NF ou 5/2, un ou deux protecteurs d'échappement en acier inox peuvent être adapté(s), voir fig. 2. • Raccordement du pilotage version pneumatique : G 1/8 ou NPT 1/8 ou G 1/4 ou NPT 1/4. • Raccordement des échappements de pilotage Possibilité de collecter les échappements selon les versions. • Commande manuelle Selon les versions les produits sont fournis sans ou avec une commande manuelle, pour fonctionnement hors tension.. Elle est signalée par le symbole ( ), sur les fig. 4, 5, 14, 15, 21 à 24, et par le rep. 10, sur les fig. 3a, 3b, 13a, 13b. La commande manuelle à impulsion ou à position maintenue (type pousser/tourner) , signalée par le symbole ( ) sur les fig. 3a, 3b, 13a et 13b, permet le fonctionnement hors tension. RACCORDEMENT ELECTRIQUE • Version à têtes magnétiques interface ASCO : Se référer à la notice d'installation complémentaire fournie avec chaque tête magnétique. Tête magnétique étanche IP65 (fig. 3a, 3b et 13a, 13b) : Adapter la bobine sur le tube (orientable sur 360°) puis le connecteur débrochable ISO 4400/EN 175101-803A (câble Ø6-10 mm), orientable par 90° x 90° (3 broches : 2 + masse). • Version à plan de pose CNOMO : Se référer à la notice d'installation complémentaire fournie avec chaque pilote. Recommandations générales Le raccordement électrique doit être réalisé par un personnel qualifié et selon les normes et règlements en vigueur. Attention : - Avant toute intervention, couper l'alimentation électrique pour mettre hors tension les composants. - Selon la tension, les composants électriques doivent être mis à la terre conformément aux normes et règlements locaux. La plupart des électrodistributeurs comportent des bobinages prévus pour mise sous tension permanente. Pour éviter toute brûlure, ne pas toucher la tête magnétique qui, en fonctionnement normal et en permanence sous tension, peut atteindre une température élevée. Si l'électrodistributeur est facilement accessible, l'installateur doit prévoir une protection de la tête magnétique. ! Avant toute opération de remise en marche, valider le retour en position "0" (non-enclenchée) de la commande manuelle, pour prévenir tout risque d'accident corporel ou matériel. • Adaptation en alimentation externe du pilotage (fig.3a, 3b, 13a et 13b, rep.6) • Recommandations générales pour raccordement pneumatique Soutenir et aligner correctement les tuyauteries pour éviter toute contrainte mécanique sur le distributeur. Au serrage, ne pas se servir de l'appareil comme d'un levier; Positionner les clés de serrage aussi près que possible du point de raccordement. Afin d’éviter toute détérioration, NE PAS TROP SERRER les raccords des tuyauteries. • Versions taraudés 1/4 (fig. 3a), 1/2 (fig. 3b) : Raccordement du distributeur : Raccorder les tuyauteries en fonction des repères indiqués sur l'étiquette. - Fonction 3/2 NF : Arrivée de pression par l'orifice 1 (1/4 ou 1/2). Utilisation par l'orifice 2. Echappement par l'orifice 3 (1/4 ou 1/2) - Fonction 5/2 : Arrivée de pression par l'orifice1. Utilisation par les orifices 2 et 4. Les échappements sont canalisés vers les orifices 3 et 5. ENTRETIEN ! Avant toute opération d'entretien ou de remise en marche, couper l'alimentation du distributeur, dépressuriser et purger, pour prévenir tout risque d'accident corporel ou matériel. Versions ATEX : Suivre impérativement lors de la phase de maintenance les recommandations de la directive 99/92/CE et normes associées. • Nettoyage L’entretien des distributeurs varie suivant leurs conditions d’utilisation. Si nécessaire procéder à un nettoyage périodique. Lors de l’intervention, les composants doivent être examinés pour détecter toute usure excessive. Un nettoyage est nécessaire lorsqu'on observe un ralentissement de la cadence alors que la pression de pilotage est correcte ou lorsqu'un bruit anormal ou une fuite est constaté. • Bruit de fonctionnement L’utilisateur ne pourra déterminer avec précision le niveau sonore émis qu'après avoir monté le composant sur l'installation. Le bruit de fonctionnement varie selon l’utilisation, le fluide et le type de matériel. • Entretien préventif - Faire fonctionner le distributeur au moins une fois par mois pour vérifier son ouverture et sa fermeture. - En cas de problème lors du montage/entretien ou en cas de doute, nous contacter ou nos représentants officiels. • Conseils en dépannage - Pression de sortie incorrecte : Vérifier la pression à l'entrée du distributeur, elle doit correspondre aux valeurs admises sur l'étiquette d'identification. Attention, respecter les valeurs minimales de pression de pilotage : 2 bar Pour prévenir tout risque d'accident corporel ou matériel, vérifier que le distributeur fonctionne correctement avant de le remettre en service. • Rechange La bobine est proposée en pièce de rechange. Si nécessaire, changer le distributeur complet. • Versions à plan de pose NAMUR (fig 13a, 13b) : Raccordement du distributeur : Raccorder les tuyauteries en fonction des repères indiqués sur l'étiquette. - Fonction 3/2 NF : Arrivée de pression par l'orifice 1 (1/4 ou 1/2). Utilisation par l'orifice 2. Echappement par l'orifice 3 (corps laiton : 1/8 ; corps acier inox : 1/4 ou 1/2). L'échappement des chambres des ressorts de rappel de l'actionneur simple effet est canalisé au travers du distributeur vers l'orifice 3 raccordable. Il est recommandé de protéger l'orifice 5 (non utilisé) tout en évitant de l'obturer. - Fonction 5/2 : Arrivée de pression par l'orifice 1 (1/4 ou 1/2). Utilisation par les orifices 2 et 4. Les échappements de l'actionneur sont canalisés au travers du distributeur vers les orifices 3 et 5 (corps laiton : 1/8 ; corps acier inox : 1/4 ou 1/2). - Raccordement des réducteurs d'échappement (corps laiton) Suivant la demande, les distributeurs série 551 sont fournis sans ou avec réducteurs d'échappement miniatures 1/8, suffixe M (fig. 13a). Ces mini-réducteurs d'échappement réglables permettent 5 3834901 INSTALLATIONS- UND WARTUNGSANWEISUNGEN Magnetventil-Baureihe 551, Messinggehäuse oder Magnetventil-Baureihe 551/553, Edelstahlgehäuse, 1/4" oder 1/2"-Gewinde oder NAMUR-Aufflanschbild 3/2 NC 5/2 - 5/3 DE deckungen an den Anschlussöffnungen und Magnetköpfen sollen nicht entfernt werden. Lagerbedingungen: geschützt lagern ; Temperatur : -40°C bis 70 °C ; relative Feuchtigkeit: 95 % Nach einer Lagerung bei niedriger Temperatur müssen die Ventile vor der Druckbeaufschlagung nach und nach an die Betriebstemperatur angepasst werden. Die Ventile sind für den Betrieb innerhalb der auf den Typenschildern angegebenen Daten ausgelegt. Änderungen an den Produkten dürfen nur nach vorheriger Zustimmung des Herstellers oder einem seiner ordnungsgemäß ermächtigten Vertreter vorgenommen werden. Die Ventile sind für den Betrieb mit neutralem Gas oder Luft, gefiltert, ausgelegt. Der max. zulässige Ventildruck von 10 bar (oder 8 bar bei einem Piezotronic-Pilotventil nach ATEX Ex ia) darf nicht überschritten werden. Beachten Sie den Mindeststeuerdruck von 2 bar. Der Einbau und die Wartung des Ventils ist von Fachpersonal auszuführen. • Pneumatisch betätigte Ausführungen, IP65 als Standard, oder Ausführungen in Übereinstimmung mit der ATEX-Richtlinie 94/9/EG für den Einsatz in durch Gase, Dämpfe, Nebel und/ oder Stäube verursachten explosionsfähigen Atmosphären. (Die Zoneneinteilung für diese Version wird auf dem ATEX-Etikett, Nr. E1, angegeben.) Schutzart, Baureihe 551: II 1 GD c T6 T85°C Ta -40°C bis +65°C. Schutzart, Baureihe 553: II 2 GD c T6 (T85°C) - T5 (T100°C) EG-Baumusterprüfbescheinigung-Nr. (Baureihe 551) INERIS 03 ATEX 0219 X Die Einhaltung der grundlegenden Gesundheits- und Sicherheitsanforderungen wird durch die Übereinstimmung mit den Europäischen Normen EN 13463-1 und EN 13463-5 gewährleistet. • Elektropneumatisch angesteuerte Ausführungen mit Magnetköpfen: - Dichte Ausführung nach IP65 oder nach der ATEX-Richtlinie 94/9/ EG für explosionsfähige Atmosphären zugelassene Ausführung. • Ausführungen mit Magnetköpfen mit ASCO-Anschlussbild, IP65 als Standard, oder für den Einsatz in explosionsfähigen Atmosphären gemäß II 3D IP65/IP67 oder gemäß ATEX Ex d, m, em, Ex ia zugelassen (Baureihe 551: II 1G/2D Ex ia IIC IP65/ IP67 oder Baureihe 553: II 2G/D Ex ia IIC IP65/IP67).). • Ausführungen mit Pilotventilen mit Aufflanschbild gemäß CNOMO E06.05.80 (Größe 30) oder CNOMO E06.36.120N (Größe 15), IP65 als Standard, oder Montage von Pilotventilen für den Einsatz in explosionsfähigen Atmosphären gemäß ATEX Ex d oder Ex ia zugelassen. Wichtiger Hinweis (CNOMO-Pilotventile): Der Einsatz in den Zonen (ATEX 1999/92/EG) richtet sich in erster Linie nach den Angaben auf dem Etikett (Abb. 10 und 20, Nr. E1 oder E2) am Gehäuse des Wegeventils. Schutzart nach ATEX 94/9/EG: II 1 GD c T6 T85°C Ta -40°C bis +65°C. EG-Baumusterprüfbescheinigung-Nr: INERIS 03 ATEX 0219 X BESCHREIBUNG DER ZERTIFIZIERUNG Von der Zertifizierung betroffene Ausführungen (Abb. 1 und 11): Baureihe 551, Gehäuse aus Messing, Baureihe 551-553, Gehäuse aus Edelstahl, monostabil (Federrückstellung) oder bistabil, 3/2-Version NC (normal geschlossen) oder 5/2, gegen Atmosphäre abgedichtete Versionen. Versionen mit oder ohne Handhilfsbetätigung: - mit 1/4“- (551) oder 1/2"- (553) Gewindeanschluss, - 551, max. Tiefe der Anschlüsse 11,5 mm. (Der Druckanschluss ist nicht am Entlüftungsanschluss 3 anzuschließen. Die “hermetisch abgedichtete” Ausführung ist nicht für eine "verteilende" Funktion oder Verwendung in NO-Funktion ausgelegt. Funktionen in Sonderausführungen auf Anfrage.). - mit Aufflanschbild gemäß NAMUR für die direkte Montage auf einfachwirkende (Funktion 3/2 NC) oder doppeltwirkende (Funktion 5/2) Pneumatik-Antriebe. Das Ventil lässt sich wahlweise auf die Funktion NC 3/2 oder 5/2 umstellen durch Montage einer der entsprechenden im Lieferumfang enthaltenen Adapterplatten auf der Unterseite des Ventils (Abb. 13a, 13b, Nr. 1a und 1b). 551, max. Tiefe der 1/4"-Anschlüsse = 11,5 mm. (Der Druckanschluss ist nicht am Entlüftungsanschluss 3 anzuschließen. Die “hermetisch abgedichtete” Ausführung ist nicht für die NO-Funktion ausgelegt. Funktionen in Sonderausführungen auf Anfrage.). - Die Verrohrung ist entsprechend der gewünschten Funktion und der Kennzeichnung der Anschlüsse auf dem Produkt und gemäß dieser Anleitung vorzunehmen. - Es ist darauf zu achten, dass keine Fremdkörper in das Ventil gelangen, um ein Blockieren der Ventilfunktion zu vermeiden. Verwenden Sie Dichtungsband oder –mittel nur spärlich. - Die Ventile sind nur mit sauberer und trockener Luft oder mit neutralem Gas zu betreiben. Empfohlene Mindest-Filterfeinheit : 50 Mikron. Der Taupunkt des verwendeten Mediums muss mindestens -10°C (18°F) unterhalb der für das Medium zulässigen Mindesttemperatur liegen. Bei der Verwendung geölter Luft ist die Beständigkeit der verwendeten Dichtungsmaterialien zu überprüfen. Die durch die ANSI/ISA-Norm S7.3 (1975) festgelegte Qualität von Instrumentenluft übersteigt die erfordDie Entlüftungsanschlüsse der Ventile sind mit den Schalldämpfern aus Edelstahl zu versehen (siehe Abb. Anforderungen und ist somit für diese Ventile zulässig. Die Entlüftungsanschlüsse der Ventile sind mit den ! Schalldämpfern aus Edelstahl zu versehen. Die Schalldämpfer sind am Anschluss 3 (3/2 NC) oder an den Anschlüssen 3 - 5 (5/2) der Ventile anzuschließen. Bei einem Einsatz im Freien, bei einer längeren Lagerung und/oder bei einem Einsatz unter schwierigen Bedingungen (Staub, aggressive Medien oder andere Schmutzpartikel) ist die Verwendung von Schalldämpfern zwingend erforderlich. Bei Verwendung einer anderen Art von Schutz als die mitgelieferten Schalldämpfern ist die Zuverlässigkeit der Ventile nicht mehr gewährleistet. - Zulässige Temperatur: -40 °C bis +80 °C (Baureihe 551); -40°C bis +60°C (Baureihe 553). - Max. Betriebsdruck: - 2 bis 10 bar - 2 bis 8 bar (ISSC/PISC/PISCIS/CFSCIS/CFSDIS/CFVTIS) Beim Zusammenbau mit einem Pilotventil nach ATEX 94/9/ EG ist die ungünstigste Kategorie, max. Betriebsdruck und Temperatur anzunehmen. Die Einhaltung der grundlegenden Gesundheits- und Sicherheitsanforderungen wird durch die Übereinstimmung mit den Europäischen Normen EN 13463-1 und EN 13463-5 gewährleistet. Die in den Abb. 4/5/14/15/21/22/23/24 angegebene Montageposition für die Pilotventile sowie die Anziehdrehmomente sind zu beachten. Für die Magnetköpfe und Pilotventile nach ATEX 94/9/EG sind die in den jeweiligen, dem Produkt beigelegten Einbau- und Wartungsanweisungen beschriebenen Einsatzvorschriften zwingend zu befolgen. ALLGEMEINE BESCHREIBUNG Ausführungen nach ATEX 94/9/EG: Siehe „Besondere Bedingungen für den sicheren Einsatz“: Hermetisch gegen Atmosphäre abgedichtete Ausführungen: Die Innenteile des Wegeschiebers sind hermetisch gegen Atmosphäre abgedichtet und somit vor dem Eindringen von aggressiven Medien geschützt. Die Entlüftungsanschlüsse können zum Schutz der Umgebung gefasst und abgeführt werden; dies wird insbesondere für Anlagen in empfindlichen Bereichen (z.B. in Labors oder der Pharma- und Nahrungsmittelindustrie) empfohlen. Bei einem Einsatz im Freien oder unter schwierigen Bedingungen (Staub, aggressive Medien oder andere Schmutzpartikel) ist es notwendig, die Entlüftungsanschlüsse entweder zu fassen und abzuführen oder mit einem Schutz (z.B. Schalldämpfer) zu versehen, um die Innenteile des Wegeschiebers zu schützen. EINBAU ! Ausführungen nach ATEX 94/9/EG: Alle Metallteile bzw. leitenden Teile sind miteinander zu verbinden und zu erden. Das Ventilgehäuse wird durch die Befestigungsschraube (Nr. F) geerdet. Die Wegeschieber können ohne Beeinträchtigung der Funktion in jeder beliebigen Einbaulage montiert werden. Ausführung mit 1/4"-Gewinde (Abb. 3a) oder 1/2"-Gewinde (Abb. 3b): Montieren Sie den Wegeschieber mit zwei Schrauben (Nr. 1); diese sind nicht im Lieferumfang enthalten. Ausführung mit Aufflanschbild gemäß NAMUR (Abb. 13a, 13b): Vor der Montage des Wegeschiebers auf dem Antrieb ist das Gerät auf die gewünschte Funktion einzustellen: - Wählen Sie die für die Funktion 3/2 NC oder 5/2 bestimmte Ad- BESONDERE BEDINGUNGEN FÜR DEN SICHEREN EINSATZ Ausführungen nach ATEX 94/9/EG: Das Ventil ist zu erden (siehe "Einbau"). Die maximale Mediumstemperatur darf die Umgebungstemperatur nicht übersteigen. Wenn der Zylinder vor Inbetriebnahme länger gelagert wird, sollte er in der Originalverpackung aufbewahrt werden. Die Schutzab- 6 3834901 INSTALLATIONS- UND WARTUNGSANWEISUNGEN Magnetventil-Baureihe 551, Messinggehäuse oder Magnetventil-Baureihe 551/553, Edelstahlgehäuse, 1/4" oder 1/2"-Gewinde oder NAMUR-Aufflanschbild apterplatte aus (Nr. 1a oder 1b). - Stellen Sie sicher, dass die Funktionsdichtung vorhanden und korrekt eingelegt ist (Nr. 7). - Befestigen Sie die Platte unter dem Ventil anhand der beiden mitgelieferten Schrauben (Nr. 8). Beachten Sie dabei die Montagerichtung: Die Nummer für die Funktion muss auf der Rückstellseite (Montagesicherung) platziert sein. - Montieren Sie die beiden O-Ringe (Nr. 9). - Platzieren Sie, falls erforderlich, die Montagesicherung auf den Antrieb: • Bei der 3/2-Platte befindet sich die Montagesicherung Ø bei A1. • Bei der 5/2-Platte befindet sich die Montagesicherung Ø bei A2. 3/2 NC 5/2 - 5/3 DE Mit diesen Mini-Abluftdrosseln lässt sich die Geschwindigkeit des Antriebs regulieren. Sie können auch angeschlossen werden (1/8"-Gewinde), um die Entlüftungen zusammenzufassen. Montage / Einstellung (Abb. 13a): 3/2-Ausführung NC = 1 Abluftdrossel an Anschluss 3 5/2-Ausführung = 2 Abluftdrosseln an den Anschlüssen 3 und 5 Drehen Sie die Schraube (4) in den Anschluss der Drossel bis zum Anschlag ein und drehen Sie sie anschließend wieder zurück, um den Entlüftungsdurchfluss zu erhöhen (jedoch nicht mehr als 2 Umdrehungen - max. Durchfluss bereits bei 1 Umdrehung). Blockieren Sie die Mutter (4a) mit einem Gabelschlüssel SW 13. Führen Sie die Grobeinstellung vor der Druckbeaufschlagung und die Feineinstellung nach der Druckbeaufschlagung durch. PNEUMATISCHER ANSCHLUSS (Abb. 3, 13a und 13b) Je nach Version 3/2 NC oder 5/2 können ein bzw. zwei Schalldämpfer aus Edelstahl montiert werden (siehe Abb. 2). • Anschluss der pneumatisch betätigten Ansteuerung: G 1/8 oder NPT 1/8 bzw. G 1/4 oder NPT 1/4. • Anschluss der Vorsteuerentlüftungen Die Entlüftungen können gefasst werden. • Handhilfsbetätigung Je nach Ausführung werden die Produkte für den spannungslosen Betrieb mit oder ohne Handhilfsbetätigung geliefert. Die Handhilfsbetätigung ist auf den Abb. 4, 5, 14, 15, 21 bis 24 mit dem Symbol ( ) gekennzeichnet und mit der Nr. 10 auf den Abb. 3a, 3b, 13a, 13b. Die auf den Abb. 3a, 3b, 13a und 13b mit dem Symbol ( ) gekennzeichnete impulsbetätigte oder rastende (Drück-Dreh) Handhilfsbetätigung ermöglicht den spannungslosen Betrieb. ELEKTRISCHER ANSCHLUSS • Ausführung mit Magnetköpfen mit ASCO-Anschlussbild: Siehe die zusätzlichen, jedem Magnetkopf beigelegten Installationsanweisungen. Magnetkopf IP65 (Abb. 3a, 3b und 13a, 13b): Zuerst den Magnet auf das Rohr montieren (um 360° drehbar) und anschließend die Leitungsdose nach ISO 4400/EN 17501-803A (Kabel-Ø6-10 mm), um 90° umsetzbar (3 Pins: 2 + Erde). • Ausführung mit CNOMO-Anschlussbild Siehe die zusätzlichen, jedem Pilotventil beigelegten Installationsanweisungen. • Allgemeine Empfehlungen Der elektrische Anschluss ist von Fachpersonal entsprechend den geltenden Normen und Richtlinien auszuführen. ACHTUNG: - Vor Beginn jeglicher Arbeiten ist sicherzustellen, dass die Komponenten spannungslos geschaltet sind. ! Um Personen- und Sachschäden zu vermeiden, muss vor - Je nach Spannungsbereich müssen elektrische Komponenten der Inbetriebnahme die Handhilfsbetätigung in die Stellung "0" einen Schutzleiteranschluss entsprechend den jeweils vor Ort (entrastet) gesetzt werden. geltenden Normen und Vorschriften erhalten. Die meisten Ventile sind mit Magneten für Dauerbetrieb ausge• Anpassung auf externe Vorsteuerung rüstet. Zur Vermeidung von Personen- und Sachschäden sollte (Abb. 3a, 3b, 13a und 13b, Nr. 6) jede Berührung mit dem Magnet vermieden werden, da dieser • Allgemeine Empfehlungen für den pneumatischen Anschluss bei längerem Betrieb heiß werden kann. Bei leicht zugänglichem Die Rohrleitungen sind ordnungsgemäß abzustützen und anzuMagnetventil sollte vom Installateur ein Schutz vorgesehen ordnen, um eine mechanische Fehlbeanspruchung des Wegewerden, um jegliches versehentliches Berühren zu vermeiden. schiebers zu vermeiden. Das Ventil darf nicht als Gegenhalter benutzt werden.Das Werkzeug ist so nahe wie möglich am WARTUNG ! Um Personen- und Sachschäden zu vermeiden, muss vor Anschlusspunkt anzusetzen. Um Schäden zu vermeiden, dürfen der Wartung oder Inbetriebnahme die Versorgung des Ventils die Rohrverbindungen nicht zu stark angezogen werden. unterbrochen sowie das Ventil drucklos geschaltet und entlüftet • Ausführungen mit 1/4"- (Abb. 3a) oder 1/2"-Gewindeanschluss werden. (Abb. 3b): Ausführungen nach ATEX: Bei der Wartung sind die BestimAnschluss des Wegeschiebers : mungen der Richtlinie 99/92/EG und zugehörige Normen Die Verrohrung ist entsprechend den Hinweisen auf dem Etikett zwingend einzuhalten. • Reinigung anzuschließen. Die Wartung der Ventile hängt von den jeweiligen Einsatzbe- Funktion 3/2 NC: Druckbeaufschlagung über Anschluss 1 (1/4 oder 1/2). Verbraudingungen ab. Sie sollten in regelmäßigen Abständen gereinigt cher über Anschluss 2. Entlüftung über Anschluss 3 (1/4 oder werden. Während des Reinigungsvorgangs sollten alle Teile auf 1/2). Verschleiß untersucht werden. Eine Reinigung ist notwendig, wenn - Funktion 5/2: sich die Schaltfrequenz bei korrektem Vorsteuerdruck verlangsDruckbeaufschlagung über Anschluss 1. Verbraucher über amt oder wenn ungewöhnliche Geräusche oder Undichtigkeiten Anschlüsse 2 und 4. Die Entlüftungen sind in den Anschlüssen festgestellt werden. 3 und 5 zusammengefasst. • Geräuschemission Diese hängt sehr stark vom Anwendungsfall, den Betriebsdaten • Ausführungen mit Aufflanschbild gemäß NAMUR (Abb. 13a, 13b): und dem Medium, mit denen das Produkt beaufschlagt wird, ab. Anschluss des Wegeschiebers: Eine Aussage über die Geräuschemission des Produktes muss Die Verrohrung ist entsprechend den Hinweisen auf dem Etikett deshalb von demjenigen getroffen werden, der das Produkt anzuschließen. innerhalb einer Maschine in Betrieb nimmt. • Vorbeugende Wartung - Funktion 3/2 NC: Druckbeaufschlagung über Anschluss 1 (1/4 oder 1/2). Verbrau- Setzen Sie das Ventil zur Überprüfung der Öffnungs- und cher über Anschluss 2. Entlüftung über Anschluss 3 (MessingSchließfunktion mindestens einmal im Monat in Betrieb. gehäuse: 1/8; Edelstahlgehäuse: 1/4 oder 1/2). Die Entlüftung - Treten Schwierigkeiten beim Einbau oder bei der Wartung auf der Rückstellfederkammern des einfachwirkenden Antriebs ist sowie bei Unklarheiten ist mit uns oder unseren zugelassenen im anschließbaren Anschluss 3 des Wegeschieber zusammenVertretern Rücksprache zu halten. gefasst. Es wird empfohlen, den (nicht verwendeten) Anschluss • Fehlerbeseitigung - Falscher Ausgangsdruck: Überprüfen Sie den Druck am Ein5 mit einem Schutz zu versehen, ohne dabei den Anschluss gang des Ventils; er muss mit den zulässigen Werten auf dem zu verschließen. Typenschild übereinstimmen. - Funktion 5/2: Beachten Sie den Mindeststeuerdruck von 2 bar. Druckbeaufschlagung über Anschluss 1 (1/4 oder 1/2). VerbrauUm Personen- und Sachschäden zu vermeiden, prüfen Sie cher über Anschlüsse 2 und 4. Die Entlüftungen sind in den vor der Wiederinbetriebnahme die richtige Funktionsweise des Anschlüssen 3 und 5 (Messinggehäuse: 1/8; Edelstahlgehäuse: Ventils. 1/4 oder 1/2) zusammengefasst. • Ersatzteile • Anschluss der Abluftdrosseln (Gehäuse aus Messing) Die Magnetspule ist als Ersatzteil erhältlich. Die Wegeventile der Baureihe 551 sind je nach Auftrag mit oder Tauschen Sie, falls erforderlich, das gesamte Ventil aus. ohne Mini-1/8"-Abluftdrosseln ausgestattet, Zusatz M (Abb. 13a). 7 3834901 Instrucciones de puesta en marcha y mantenimiento Distribuidores SERIE 551, cuerpo de latón, o SERIE 551-553, cuerpo de acero inoxidable, roscado 1/4, 1/2 o con plano de acoplamiento NAMUR 3/2 NC 5/2 - 5/3 ES DESCRIPCIÓN DE LA CERTIFICACIÓN En caso de almacenaje prolongado antes de la puesta en Versiones afectadas por esta puesta en marcha (fig 1 y 11) : marcha, el distribuidor debe permanecer en su embalaje Serie 551, cuerpo de latón, o Serie 551,553, cuerpo de de origen. Los elementos de protección de los orificios de acero inox., monoestable (retorno resorte) o biestable, racordaje y de las cabezas magnéticas deben permanecer versión 3/2 NC (normalmente cerrada) o 5/2, versiones colocados. estancas con respecto a la atmósfera. Versiones sin o Condiciones de almacenaje : al abrigo de intemperies; temcon mando manual : peratura : - 40°C a +70°C; humedad relativa : 95 % - con conexión roscada 1/4 (551) o 1/2 (553) - 551, pro- Después de un almacenaje a baja temperatura, los distribuifundidad máxima de los orificios de racordaje 11,5 mm dores deben ser puestos progresivamente a la temperatura (No conectar la alimentación de presión al orificio 3 de ambiente de funcionamiento antes de la primera puesta bajo escape. La construcción “estanca a la atmósfera” no presión. está adaptada para la función “distribuidora” o utiliza- Los distribuidores están diseñados para los campos de ción en función NA. Funciones disponibles en versión funcionamiento indicados en la placa de características. No específica, consultar). puede realizarse ninguna modificación en el material sin el - con plano de acoplamiento según recomendación acuerdo previo del fabricante o de su representante. Estos NAMUR para adaptación directa en actuador neumático de distribuidores están previstos para funcionar con aire o simple efecto (función 3/2 NC) o doble efecto (función 5/2). gases neutros filtrados. No sobrepasar la presión máxima Un mismo distribuidor se adapta a los dos tipos de mando admisible = 10 bar (o 8 bar con piloto piezotronic ATEX Ex mediante la colocación en la parte inferior de una de las dos ia). Respetar el valor mínimo de presión de pilotaje de 2 bar. placas interface 3/2 NC o 5/2 provistas (fig. 13a, 13b, ref. 1a La puesta en marcha y el mantenimiento de estos productos y 1b). 551, 1/4, profundidad máxima de los orificios de deben ser realizadas por personal competente. racordaje 1/4 = 11,5 mm (No conectar la alimentación de • Versiones de mando neumático standard IP65 o presión al orificio 3 de escape. La construcción “estan- previstas para atmósferas explosivas bajo forma de gas, ca a la atmósfera” no está adaptada para la función NA. vapores, nieblas y polvos según la directiva ATEX 94/9/CE. Funciones disponibles en versión específica, consultar). (La clasificación por zona de esta versión se define por la - Conectar las tuberías según las funciones deseadas tenien- etiqueta ATEX, ref.E1). do en cuenta las referencias de los orificios marcados en el Modo de protección, serie 551: II 1 GD c T6 T85°C Ta -40°C a +65°C producto y en esta documentación. Modo de protección, serie 553: II 2 GD c T6 (T85°C) - T5 (T100°C) - Verifique que ningún cuerpo extraño penetre en el circuito con el fin de evitar todo bloqueo de la válvula. Limitar la uti- Certificación CE : INERIS 03 ATEX 0219 X lización de goma o pasta de estanquidad. El respeto de las exigencias esenciales en lo relativo a seguridad - Estos distribuidores y electrodistribuidores deben ser uti- y salud está asegurado por la conformidad a las normas europeas lizados solamente con aire, limpio y seco, o un gas neutro. EN 13463-1 y EN 13463-5. Filtración mínima recomendada 50 micras. El punto de rocío • Versiones con mando electroneumático equipadas con del fluido utilizado debe ser como mínimo cabezas magnéticas : -10°C (18°F) por debajo de la temperatura mínima a la cual - estancas IP65 o certificadas para atmósferas explosivas el fluido puede ser sometido. En caso de utilización de aire según la Directiva ATEX 94/9/CE lubricado, el lubricante debe ser compatible con los elastó- Versiones cabezas magnéticas según plano de acoplameros utilizados. La calidad "aire instrumento" definida por miento ASCO, norma IP65 o para atmósferas explosivas, la norma ANSI/ISA S7.3 (1975) es superior a las exigencias II 3D IP65/IP67 o ATEX Ex d, m, em, Ex ia (serie 551: II 1G/2D Ex ia IIC IP65/IP67 o serie 553: II 2G/D Ex ia IIC requeridas y constituye de hecho, un "medio" aceptable para estas válvulas. IP65/IP67). - Versiones con pilotos, según plano de acoplamiento Proteger los orificios de escape de los distribuidores CNOMO E06.05.80 (talla 30) o CNOMO E06.36.120N ! y de los pilotos mediante protectores de escape de acero (talla 15), norma IP 65 o montaje de pilotos para atmósinox. Para el distribuidor, conectar estos protectores al feras explosivas ATEX, Ex d o Ex ia. orificio 3 (3/2 NC) o a los orificios 3 - 5 (5/2). En ambiente Atención (pilotos CNOMO) : La colocación en zonas (ATEX exterior, almacenaje prolongado, y/o en presencia de 1999/92/CE), está definida prioritariamente por el marcaje polvo, líquidos y agentes presentes en el ambiente, es indicado en la etiqueta fig. 10 y 20, (ref. E1 o E2) colocada obligatoria la presencia de protectores de escape. La en el cuerpo del distribuidor. Modo de protección, según fiabilidad de la válvula no estará garantizada en caso ATEX 94/9/CE : II 1GD c T6 T85°C Ta -40°C a +65°C. de utilización de un medio de protección de los escapes diferente a los recomendados. Certificación CE : INERIS 03 ATEX 0219 X - Rango de temperatura autorizado : Tener en cuenta la categoría, rango de presión máxima -40°C a +80°C (serie 551); -40°C a +60°C (serie 553). de funcionamiento y temperatura la menos favorable - Rango de presión máxima de funcionamiento : durante el montaje con un piloto ATEX 94/9/CE. El - 2 a 10 bar respeto de las exigencias esenciales en lo relativo a se- 2 a 8 bar (ISSC/PISC/PISCIS/CFSCIS/CFSDIS/CFVTIS) guridad y salud está asegurado por la conformidad a las normas europeas EN 13463-1 y EN 13463-5. Respete el DESCRIPCIÓN GENERAL sentido de montaje de los pilotos indicado por las figuras Versiones ATEX 94/9/CE : Ver "condiciones especiales para 4/5/14/15/21/22/23/24 y los pares de apriete indicados. una utilización segura". Versiones estancas con respecto a la atmósfera : Los Para las cabezas magnéticas y pilotos ATEX 94/9/CE, siga componentes internos del distribuidor están aislados de la imperativamente las prescripciones de utilización descriatmósfera exterior, protegiéndole así de todo entorno agre- tas en cada hoja de puesta en marcha específica provista sivo. Todos los orificios de escape son canalizables, por lo con el producto. que aseguran mayor protección del entorno, particularmente MONTAJE Versiones ATEX 94/9/CE : Compruebe que todas las partes recomendada para las instalaciones en zonas sensibles como ! metálicas o conductoras estén siempre interconectadas salas blancas, industrias farmacéuticas o agro-alimentarias. Es necesario canalizar o equipar los escapes para proteger y unidas a tierra. La unión a tierra del cuerpo de distribuidor los componentes internos del distribuidor en el caso de uti- se realiza mediante el montaje del tornillo de fijación (ref. F). lización en el exterior o en entorno difícil (polvos, líquidos u Los distribuidores pueden ser montados en cualquier posición. otros agentes). Versiones roscadas 1/4 (fig. 3a), 1/2 (fig 3b) : Montar el distribuidor con la ayuda de dos tornillos (ref.1), no CONDICIONES ESPECIALES PARA UNA UTILIZACIÓN SEGURA provistos. ATEX 94/9/CE : El distribuidor debe tener toma a tierra (Ver Versiones con plano de acoplamiento NAMUR (fig. 13a, 13b) : Montaje). Antes del montaje del distribuidor en el actuador, adapte el La temperatura máxima del fluido no debe exceder la tem- aparato a la función deseada : peratura ambiente. - Seleccione la placa interface correspondiente a la función 8 3834901 Instrucciones de puesta en marcha y mantenimiento Distribuidores SERIE 551, cuerpo de latón, o SERIE 551-553, cuerpo de acero inoxidable, roscado 1/4, 1/2 o con plano de acoplamiento NAMUR necesaria 3/2 NC o 5/2 (ref.1a o 1b). - Compruebe la presencia y correcta colocación de la junta de forma (ref.7). - Monte la placa bajo el distribuidor con la ayuda de los 2 tornillos (ref. 8) provistos, respetando el sentido de montaje: la referencia de función debe estar colocada en el lado de retorno (guía). - Monte las dos juntas tóricas (ref.9). - Coloque, si fuera necesario, la guía en el actuador : • En la placa 3/2, el orificio guía Ø 5 está situado en A1. • En la placa 5/2, el orificio guía Ø 5 está situado en A2. 3/2 NC 5/2 - 5/3 ES se pueden racordar (rosca 1/8) para canalizar los escapes. Montaje / Regulación (fig. 3a) : Versión 3/2 NC = 1 reductor para adaptar en el orificio 3 Versión 5/2 = 2 reductores para adaptar en los orificios 3 y 5 Apriete en el orificio el tornillo (4) del reductor hasta que haga tope, después desatornille para aumentar el caudal de escape sin sobrepasar las 2 vueltas (caudal máximo obtenido a partir de 1 vuelta). Bloquee la contra-tuerca (4a) con una llave plana de 13 mm. La regulación debe realizarse sin presión, hay que afinarla durante las pruebas con presión. RACORDAJE NEUMÁTICO (fig. 3a, 3b, 13a y 13b) CONEXIÓN ELÉCTRICA Según la versión 3/2 NC o 5/2, se pueden adaptar uno o • Versión con cabezas magnéticas interface ASCO : dos protectores de escape de acero inoxidable, ver fig. 2. Remitirse a la hoja de instalación complementaria provista • Racordaje del pilotaje versión neumática : con cada cabeza magnética. G 1/8 o NPT 1/8 o G 1/4 o NPT 1/4. Cabeza magnética estanca IP65 (fig. 3a, 3b, 13a y 13b) : • Racordaje de los escapes de pilotaje Adaptar la bobina en el tubo (orientable en 360°) después Posibilidad de canalizar los escapes según las versiones. el conector desenchufable ISO 4400/EN 175101-803A • Mando manual (cable Ø6-10 mm), orientable en 90° x 90° (3 pines : 2 + Según las versiones los productos se suministran sin o con un manmasa). do manual, para funcionamiento sin tensión. Se indica mediante el • Versión con plano de acoplamiento CNOMO : Remisímbolo ( ), en las fig. 4, 5, 14, 15, 21 a 24, y para la ref. 10 en las fig. tirse a la hoja de instalación complementaria provista 3a, 3b, 13a, 14b. con cada piloto. El mando manual de impulsión o de posición mantenida • Recomendaciones generales (tipo pulsar/girar), indicado por el símbolo ( ) en las fig. La conexión eléctrica debe ser realizada por personal 3a, 3b, 13a y 13b , permite el funcionamiento sin tensión. cualificado y según las normas y reglamentos en vigor. Atención : ! Antes de cualquier operación de puesta en marcha, - Antes de cualquier intervención, corte la alimentación compruebe el retorno a la posición "0" (no-enclavado) del eléctrica para quitar la tensión de los componentes. mando manual, para prevenir todo riesgo de accidente - Según la tensión, los componentes eléctricos deben tener corporal o material. toma a tierra conforme a las normas y reglamentos locales. • Adaptación en alimentación externa del pilotaje La mayoría de los electrodistribuidores están provistos de (fig.3a, 3b, 13a y 13b, ref.6) bobinados previstos para la puesta bajo tensión permanente. • Recomendaciones generales para racordaje neumático Para evitar quemaduras, no toque la cabeza magnética Sostenga y alinee correctamente las tuberías para evitar que, en funcionamiento normal y en permanencia bajo cualquier tensión mecánica en el distribuidor. Al apretar, tensión, puede alcanzar una temperatura elevada. Si el no utilice el aparato como palanca; Posicione las llaves electrodistribuidor es de fácil acceso, el instalador debe de apriete lo mas cerca posible del punto de racordaje. prever una protección de la cabeza magnética. Con el fin de evitar deterioros, NO APRIETE DEMASIADO los racores de las tuberías. MANTENIMIENTO ! Antes de cualquier operación de mantenimiento o de puesta en marcha, corte la alimentación del distribuidor, • Versiones roscadas 1/4 (fig. 3a, 1/2 (fig 3b) : despresurice y purgue, para prevenir riesgos de accidente Racordaje del distribuidor : Racordar las tuberías en función de las referencias indi- corporal o material. Versiones ATEX : Siga imperativamente durante la fase cadas en la etiqueta. - Función 3/2 NC : de mantenimiento las recomendaciones de la Directiva Entrada de presión por el orificio 1 (1/4 o 1/2). Utilización 99/92/CE y normas asociadas • Limpieza por el orificio 2. Escape por el orificio 3 (1/4 o 1/2). El mantenimiento de los distribuidores varia con sus - Función 5/2 : condiciones de utilización. Si fuese necesario, realizar Entrada de presión por el orificio 1. Utilización por los una limpieza periódica. Durante la intervención, los comorificios 2 y 4. Los escapes están canalizados hacia los orificios 3 y 5. ponentes deben ser examinados para detectar cualquier desgaste excesivo. Cuando se observa un ralentizamiento de la frecuencia aunque la presión de pilotaje sea correc• Versiones con plano de acoplamiento NAMUR (fig 13a, 13b) : ta o cuando se percibe un ruido anormal o una fuga, es Racordaje del distribuidor : Racordar las tuberías en función de las referencias indinecesaria una limpieza. cadas en la etiqueta. • Ruido de funcionamiento - Función 3/2 NC : El usuario solamente podrá determinar con precisión el nivel sonoro emitido después de haber montado el componente Entrada de presión por el orificio 1 (1/4 o 1/2). Utilización en la instalación. El ruido de funcionamiento varia según por el orificio 2. Escape por el orificio 3 (cuerpo de latón : 1/8; la utilización, el fluido y el tipo de material. cuerpo de acero inox : 1/4 o 1/2). El escape de los alojamientos de los resortes de retorno • Mantenimiento preventivo del actuador de simple efecto se canaliza a través del - Hacer funcionar el distribuidor al menos una vez al mes distribuidor hacia el orificio 3 racordable. Se recomienda para verificar su apertura y su cierre. proteger el orificio 5 (no utilizado) evitando obturarle. - En caso de problemas durante el montaje/mantenimiento - Función 5/2 : o en caso de duda, contactar con ASCO Numatics o sus representantes oficiales. Entrada de presión por el orificio 1 (1/4 o 1/2). • Consejos de reparación Utilización por los orificios 2 y 4. - Presión de salida incorrecta : Comprobar la presión en Los escapes del actuador están canalizados a través del la entrada del distribuidor, esta debe corresponder a los distribuidor hacia los orificios 3 y 5 (cuerpo de latón : 1/8; valores admitidos en la etiqueta de identificación. Atención, cuerpo de acero inox. : 1/4 o 1/2). respetar los valores mínimos de presión de pilotaje : 2 bar - Racordaje de los reductores de escape (cuerpo de Para prevenir cualquier riesgo de accidente personal o latón) material, comprobar que el distribuidor funciona correcSegún la demanda, los distribuidores serie 551 se sumitamente antes de la puesta en marcha. nistran sin o con reductores de escape miniatura 1/8, sufijo • Recambio M (fig. 13a). La bobina existe como pieza de recambio. Estos mini-reductores de escape regulables permiten Si fuese necesario, cambiar el distribuidor completo. adaptar la velocidad de maniobra del actuador. También 9 3834901 Istruzioni di installazione e manutenzione Distributori SERIE 551, corpo ottone, o SERIE 551-553, corpo acciaio inox, filettati 1/4 o 1/2, o a piano di posa NAMUR DESCRIZIONE DELLA CERTIFICAZIONE Versioni interessate dalla presente certificazione (fig 1 e 11) : Serie 551, corpo ottone, o Serie 551, 553, corpo acciaio inox, monostabile (ritorno a molla) o bistabile, versione 3/2 NC (normalmente chiusa) o 5/2, versioni stagne all'atmosfera. Versioni senza comando manuale o con comando manuale : - con raccordo filettato 1/4 (551) o 1/2 (553) - 551, profondità massima della porta 11,5 mm. (Non connettere l’ingresso della pressione alla porta di scarico 3. La costruzione “a protezione dell’ambiente” non è adatta da una funzione di “distribuzione” o a un impiego senza NESSUNA funzione. Mettersi in contatto con noi per le funzioni disponibili in versioni specifiche). - con piano di posa secondo raccomandazioni NAMUR per montaggio diretto su attuatore pneumatico a semplice effetto (funzione 3/2 NC) o doppio effetto (funzione 5/2). Uno stesso distributore si adatta alle due funzioni mediante posizionamento sulla parte inferiore di una delle due piastre interfaccia 3/2 NC o 5/2 fornite (fig. 13a, 13b, rif. 1a e 1b. 551, profondità massima della porta 11,5 mm(Non connettere l’ingresso della pressione alla porta di scarico 3. La costruzione “a protezione dell’ambiente” non è adatta a un impiego senza NESSUNA funzione. Mettersi in contatto con noi per le funzioni disponibili in versioni specifiche). - Raccordare le tubazioni secondo le funzioni desiderate, tenendo conto dei riferimenti delle vie marcati sul prodotto e nella presente documentazione. - Controllare che nessun corpo estraneo penetri all'interno del circuito, onde evitare il blocco della valvola. Limitare l'utilizzo di nastro o pasta per tenute. - I distributori ed elettrodistributori devono essere utilizzati solo con aria pulita e secca, o con gas neutro. Si raccomanda un filtraggio minimo di 50 micron. Il punto di rugiada dei fluidi deve essere di almeno -10°C (18°F) al di sotto della temperatura minima a cui i fluidi possono essere esposti. Se viene usata aria lubrificata, il lubrificante deve essere compatibile con gli elastomeri usati. La qualità "aria strumenti" definita dalla norma ANSI/ISA S7.3 (1975) supera i requisiti ed è pertanto un supporto accettabile per queste valvole. Tutte le connessioni di scarico delle valvole e dei piloti devono ! essere protette con silenziatori in acciaio inox. Collegare i silenziatori alla connessione (3/2 NC) o connessioni 3-5 (5/2). Per utilizzo esterno, o in giacenza a magzzino per lunghi periodi, e/o esposte in ambienti difficili (polveri, liquidi, ecc.), devono essere utilizzati i silenziatori. L'affidabilità della valvola non viene garantita nel caso di utilizzo di un silenziatore differente da quello prescritto. - Campo di temperatura autorizzato: da -40°C a +80°C (serie 551); da -40°C a +60°C (serie 553). - Campo di pressione max di funzionamento: - da 2 a 10 bar - da 2 a 8 bar (ISSC/PISC/PISCIS/CFSCIS/CFSDIS/CFVTIS) DESCRIZIONE GENERALE Versioni ATEX 94/9/CE : Vedere "condizioni speciali per un utilizzo sicuro". Versioni stagne all'atmosfera : I componenti interni del distributore sono isolati dall'atmosfera esterna, quindi protetti dagli ambienti aggressivi. Tutte le vie di scarico se canalizzate, assicurano una migliore protezione dagli ambienti aggressivi, particolarmente raccomandata per installazioni in zone sensibili come sale bianche, industrie farmaceutiche o agroalimentari. E' necessario canalizzare o predisporre gli scarichi per proteggere i componenti interni del distributore in caso di utilizzo all'esterno o in ambiente difficile (polveri, liquidi o altri agenti). CONDIZIONI SPECIALI PER UN UTILIZZO SICURO ATEX 94/9/CE : Il distributore deve avere la messa a terra (Vedere Montaggio). La temperatura max del fluido non deve superare la temperatura ambiente. In caso di stoccaggio prolungato prima della messa in funzione, il distributore deve restare nel suo imballaggio d'origine. Gli elementi di protezione delle vie di raccordo e delle teste magnetiche devono rimanere al proprio posto. Condizioni di stoccaggio: al riparo dalle intemperie; temperatura : da - 40°C a +70°C; umidità relativa : 95 % 3/2 NC 5/2 - 5/3 IT Dopo uno stoccaggio a bassa temperatura, i distributori devono essere riportati progressivamente alla temperatura ambiente di funzionamento prima di essere messi in pressione per la prima volta. I distributori sono progettati per i campi di funzionamento indicati sulla etichetta di segnalazione. Nessuna modifica può essere apportata sui materiali senza il previo accordo del fabbricante o dei suoi rappresentanti. Questi elettrodistributori sono previsti per aria o gas neutri filtrati. Non superare la pressione max ammessa = 10 bar (o 8 bar con pilota piezotronic ATEX Ex ia). Rispettare il valore minimo di funzionamento di 2 bar. La messa in funzione di questi prodotti deve essere effettuata da personale competente • Versioni a comando pneumatico standard IP65 o previste per atmosfere pericolose come gas, vapori, nebbie e polveri secondo la Direttiva ATEX 94/9/CE. La classificazione delle zone di questa versione è definita nell'etichetta ATEX, rif.E1). Modo di protezione, serie 551: II 1 GD c T6 T85°C Ta da -40°C a +65°C Modo di protezione, serie 553: II 2 GD c T6 (T85°C) - T5 (T100°C) Certificato di esame CE di tipo (serie 551): INERIS 03 ATEX 0219 X Il rispetto dei requisiti essenziali in materia di sicurezza e salute è assicurata dalla conformità alle norme europee EN 13463-1 e EN 13463-5. • Versioni a comando elettropneumatico dotate di teste magnetiche: - protezione IP65 o omologate per atmosfere pericolose secondo la Direttiva ATEX 94/9/CE - Versioni con teste magnetiche secondo piano di posa ASCO, standard IP65 o per atmosfere pericolose, II 3D IP65/IP67 o ATEX Ex d, m, em, Ex ia (serie 551: II 1G/2D Ex ia IIC IP65/IP67 o serie 553: II 2G/D Ex ia IIC IP65/IP67). - Versioni con piloti, secondo piano di posa CNOMO E06.05.80 (taglia 30) o CNOMO E06.36.120N (taglia 15), standard IP 65 o montaggio di piloti per atmosfere pericolose ATEX, Ex d o Ex ia. Attenzione (piloti CNOMO) : L'installazione in zone (ATEX 1999/92/CE), è determinato in via prioritaria dalla marcatura indicata sull'etichetta (fig. 10 e 20, rif. E1 o E2) situata sul corpo del distributore. Modo di protezione secondo ATEX 94/9/CE : II 1 GD c T6 T85°C Ta da -40°C a +65°C. Certificato di esame CE di tipo : INERIS 03 ATEX 0219 X Considerare la categoria, pressione massimo di funzionamento e la temperatura meno favorevoli quando si monta un gruppo con pilota ATEX 94/9/CE. Il rispetto dei requisiti essenziali in materia di sicurezza e salute è assicurato dalla conformità alle norme europee EN 13463-1 e EN 13463-5. Rispettare il senso di montaggio dei piloti indicato nelle figure dalla 4/5/14/15/21/22/23/24 e le coppie di serraggio indicate. Per le teste magnetiche ed i piloti ATEX 94/9/CE, seguire tassativamente le istruzioni per l'uso riportate nelle rispettive avvertenze specifiche per la messa in funzione fornite con il prodotto. MONTAGGIO ! Versioni ATEX 94/9/CE : Accertarsi che tutte le parti metalliche o conduttrici siano sempre interconnesse e messe a terra. La messa a terra del corpo del distributore si esegue montando la vite di fissaggio (rif. F). I distributori possono essere montati in qualsiasi posizione. Versioni filettate 1/4 (fig. 3a); 1/2 (fig. 3b) : Montare il distributore servendosi di due viti (rif.1), non comprese nella fornitura. Versioni con piano di posa NAMUR (fig. 13a, 13b) : Prima di montare il distributore sull'attuatore, adattare il componente alla funzione scelta : - Selezionare la piastra interfaccia sulla funzione desiderata 3/2 NC o 5/2 (rif.1a o 1b). - Verificare la presenza e l'inserimento corretto della guarnizione sagomata (rif.7). - Assemblare piastra e distributore con le 2 viti (rif.8) fornite, rispettando il senso di montaggio: il riferimento della funzione 10 3834901 Istruzioni di installazione e manutenzione Distributori SERIE 551, corpo ottone, o SERIE 551-553, corpo acciaio inox, filettati 1/4 o 1/2, o a piano di posa NAMUR deve essere posizionato lato ritorno (spina di riferimento). - Montare le due guarnizioni OR (rif.9). - Posizionare, se necessario, la spina di riferimento sull'attuatore : • Sulla piastra 3/2, la spina di riferimento Ø 5 è situata in A1. • Sulla piastra 5/2, la spina di riferimento Ø 5 è situata in A2. 3/2 NC 5/2 - 5/3 IT Serrare la vite nella via (4) del regolatore fino ad arresto battuta, poi svitare per aumentare la portata dello scarico senza mai superare i 2 giri (la portata max si ottiene a partire da 1 giro). Bloccare il contro-dado (4a) mediante chiave da 13 mm. La regolazione deve essere effettuata in assenza di pressione, l'ottimizzazione effettuando delle prove dopo la pressurizzazione. RACCORDO PNEUMATICO (fig. 3a, 3b 13a, 13b) A seconda della versione 3/2 NC o 5/2, vengono fornite una o due protezioni di scarico in acciaio inox (vedere fig. 2). CONNESSIONE ELETTRICA • Raccordo di pilotaggio automatico : • Versione con testa magnetica interfaccia ASCO : fare G 1/8 o NPT 1/8 o G 1/4 o NPT 1/4. riferimento alle istruzioni d'installazione complementari • Raccordo degli scarichi di pilotaggio fornite con ciascuna testa magnetica. Possibilità di raccogliere gli scarichi secondo la versione. Testa magnetica con protezione IP65 (fig. 3a, 3b, 13a e 13b) : Montare la bobina sul tubo (orientabile a 360°) poi il • Comando manuale A seconda delle versioni i prodotti sono forniti con o senza connettore disinnestabile ISO 4400/EN 175101-803A (cavo Ø6-10 mm), orientabile a 90° (3 morsetti : 2 + massa). comando manuale, per funzionamento senza tensione. Essa è segnalata dal simbolo ( ) sulle fig. 4, 5, 14, 15, da 21 a 24, e dal rif. 10 sulle fig. 3a, 3b, 13a, 13b. • Versione a piano di posa CNOMO: fare riferimento Il comando manuale ad impulsi o posizione mantenuta (tipo alle istruzioni d'installazione complementari fornite con spingere/girare), segnalata dal simbolo ( ) sulle fig. 3a, ciascun pilota. 3b, 13a e 13b, permette il funzionamento senza tensione. • Raccomandazioni generali ! Prima di qualsiasi operazione di rimessa in funzione, Il collegamento elettrico deve essere realizzato da personale convalidare il ritorno sulla posizione "0" (non-inserita) qualificato e secondo le norme ed i regolamenti in vigore. del comando manuale, per evitare qualsiasi rischio di Attenzione: incidente a cose o persone. - Prima di qualsiasi intervento, togliere l'alimentazione • Montaggio con alimentazione esterna di pilotaggio elettrica per mettere i componenti fuori tensione. (fig.3a, 3b, 13a e 13b, rif.6) - A seconda della tensione, i componenti elettrici devono essere messi a terra in conformità alle norme ed i regola• Raccomandazioni generali per il raccordo pneumatico menti locali. Supportare ed alimentare correttamente le tubazioni per La maggior parte dei distributori hanno bobine previste evitare qualsiasi sollecitazione meccanica sul distributore. per messa in tensione permanente. Per evitare bruciature, Serrando, non servirsi dell'apparecchio come se fosse una non toccare la testa magnetica che, in funzionamento norleva; posizionare le chiavi di serraggio il più vicino possibile male e permanentemente sotto tensione, può raggiungere al punto di raccordo. Per evitare qualsiasi guasto, NON una temperatura elevata. Se l'elettrovalvola è facilmente SERRARE TROPPO i raccordi delle tubazioni. accessibile, l'installatore deve prevedere una protezione della testa magnetica. • Versioni filettate 1/4 (fig. 3a); 1/2 (fig 3b): Raccordo del distributore: MANUTENZIONE ! Prima di qualsiasi operazione di manutenzione o di Collegare le tubazioni secondo i riferimenti indicati sull'etichetta. rimessa in funzione, togliere l'alimentazione al distributore, - Funzione 3/2 NC : depressurizzare e spurgare, per evitare qualsiasi rischio di Ingresso della pressione attraverso della via 1 (1/4 o 1/2). incidente a cose o persone. Utilizzo attraverso la via 2. Scarico attraverso la via 3 (1/4 Versioni ATEX : in fase di manutenzione seguire tassao 1/2) tivamente le raccomandazioni della direttiva 99/92/CE e norme associate. - Funzione 5/2 : Ingresso della pressione attraverso la via 1. Utilizzo attra- • Pulizia verso le vie 2 e 4. La manutenzione dei distributori varia secondo le loro Gli scarichi sono incanalati verso le vie 3 e 5. condizioni di impiego. Se necessario, procedere ad una pulizia periodica. Quando si segue un intervento, si devono esaminare i componenti per individuare i punti troppo usurati. • Versioni con piano di posa NAMUR (fig 13a, 13b) : E' necessaria una pulizia quando si osserva un rallentamento Raccordo del distributore: Collegare le tubazioni secondo i riferimenti indicati sull'eti- della cadenza, pur essendo corretta la pressione di pilotaggio o quando si sente un rumore anomalo o si constata una fuga. chetta. • Rumore di funzionamento - Funzione 3/2 NC : Ingresso della pressione attraverso la via 1 (1/4 o 1/2). L’utente potrà determinare con precisione il livello sonoro amUtilizzo attraverso la via 2. Scarico attraverso la via 3 messo solo dopo avere montato il componente sull’installazione. (corpo in ottone: 1/8; corpo in acciaio inox: 1/4 o 1/2). Il rumore di funzionamento varia secondo l’uso, il fluido ed il tipo Lo scarico delle camere delle molle di ritorno dell'attuatore di materiale. a semplice effetto è canalizzato attraverso il distributore • Manutenzione preventiva verso la connessione 3 raccordabile. Si raccomanda di - Fare funzionare il distributore almeno una volta al mese proteggere la via 5 (non utilizzata) evitando di tapparla. per verificarne l'apertura e la chiusura. - Funzione 5/2 : - In caso di problema al montaggio o alla manutenzione Ingresso della pressione attravero la via 1 (1/4 o 1/2). o in caso di dubbio, contattare ASCO Numatics o i suoi Utilizzo attraverso le vie 2 e 4. rappresentanti ufficiali. Gli scarichi dell'attutore sono incanalati verso le vie 3 e • Consigli per la riparazione 5 (corpo in ottone: 1/8; corpo in acciaio inox : 1/4 o 1/2). Pressione di uscita anomala: verificare la pressione all’entrata del distributore; deve corrispondere ai valori ammessi - Raccordo dei regolatori di scarico (corpo ottone) sull'etichetta dati. A seconda della richiesta, i distributori serie 551 sono forniti Attenzione. Rispettare i valori minimi di pressione di pilotagcon o senza regolatori di scarico miniaturizzati 1/8, suffisso gio: 2 bar. M (fig. 13a). Per evitare qualsiasi rischio d’incidente a cose o persone, Tali mini-regolatori di scarico regolabili permettono di adat- verificare che il distributore funzioni correttamente prima di tare la velocità di manovra dell'attuatore. Sono ugualmente rimetterlo in servizio. raccordabili (filettatura 1/8) per collegare gli scarichi. • Ricambi Montaggio / Regolazione (fig. 3a) : La bobina viene proposta come parte di ricambio. Se necesVersione 3/2 NC = 1 regolatore da montare sulla via 3 sario, sostituire l'elettrodistributore o il distributore completo. Versione 5/2 = 2 regolatore da montare sulle vie 3 e 5 11 3834901 ALGEMENE INSTALLATIE- EN ONDERHOUDSINSTRUCTIES Magneetafsluiters uit de 551-serie met messing huis, of uit de 551-/553-serie met roestvaststalen huis, en voorzien van ¼”- of ½”-schroefdraad of een NAMUR-aansluiting OMSCHRIJVING VAN DE GOEDKEURING Versies waar de goedkeuring betrekking op heeft (afb. 1 en 11): Dit zijn monostabiele (met terugstelveer) of bistabiele magneetafsluiters met een afsluiterhuis van messing (551-serie) of van roestvast staal (series 551, 553), met 3/2 NC- (normaal gesloten) of 5/2-werking in een van de buitenlucht geïsoleerde uitvoering. Versies met en zonder handmatige bediening: - met ¼” (551) of ½” (553) schroefdraadaansluitingen - 551, met ¼” getapte aansluiting max. poortdiepte 11,5 mm. (Sluit de druktoevoer niet aan op ontluchtingspoort 3. De “hermetisch afgedichte" constructie is niet geschikt als "verdeelfunctie" of voor gebruik in NO functie. Speciale uitvoeringen op aanvraag). - met NAMUR-aansluiting voor directe montage op enkelwerkende (3/2 NC) of dubbelwerkende (5/2) pneumatische actuatoren. De werking van de afsluiter kan van 3/2 NC naar 5/2 worden omgebouwd door de meegeleverde 3/2 NC- of 5/2-functieplaat onder de afsluiter te monteren (fig.13a, 13b, zie 1a en 1b). 551, Met ¼” max. poortdiepte 11,5 mm. (Sluit de druktoevoer niet aan op ontluchtingspoort 3. De “hermetisch afgedichte" constructie is niet geschikt voor gebruik in NO functie. Speciale uitvoeringen op aanvraag). - Neem bij het aansluiten van de benodigde leidingen voor de gewenste functie de aanwijzingen in dit document en de poortmarkeringen op het product in acht. - Zorg dat er geen vuil in de leidingen kan komen, om schade aan de afsluiter te voorkomen. Beperk het gebruik van afdichttape en afdichtingsmateriaal tot een minimum. - Deze afsluiters zijn bedoeld voor gebruik met schone en droge lucht of inert gas. Aanbevolen filtratieminimum: 50 micron. Het dauwpunt van het gebruikte medium dient minstens 10°C onder de minimumtemperatuur te liggen waaraan het medium ooit zal worden blootgesteld. Indien gesmeerde lucht wordt gebruikt, dient het smeermiddel geschikt te zijn voor de gebruikte elastomeren. Instrumentatielucht conform ANSI/ISA norm S7.3 (1975) voldoet ruimschoots aan deze vereisten en is daardoor een geschikt medium voor deze afsluiters. Alle uitlaatpoorten van de afsluiters en stuurkleppen ! moeten worden beschermd met roestvaststalen uitlaatbeschermers. Sluit de uitlaatbeschermers aan op poort 3 (3/2 NC) of poorten 3 - 5 (5/2). Bij gebruik buiten of opslag voor langere tijd en/of bij blootstelling aan veeleisende omgevingen (stof, vloeistoffen, enz.) moeten uitlaatbeschermers worden gebruikt. De betrouwbaarheid van de afsluiter kan niet worden gegarandeerd indien een uitlaatbescherming anders dan de geleverde bescherming wordt gebruikt. - Toegestaan temperatuurbereik: -40°C tot +80°C (serie 551); -40°C tot +60°C (serie 553). - Maximale werkdruk: - 2 tot 10 bar - 2 tot 8 bar (ISSC/PISC/PISCIS/CFSCIS/CFSDIS/CFVTIS) 3/2 NC 5/2 - 5/3 NL hem niet gebruikt. Laat de bescherming op de aansluitpoorten en over de magneetkoppen zitten. Opslageisen: beschermen tegen weersinvloeden, opslagtemperatuur: -40ºC tot + 70ºC; relatieve vochtigheid: 95% Na opslag bij een lage temperatuur dienen de schuifafsluiters geleidelijk aan op gebruikstemperatuur te worden gebracht voordat ze onder druk worden gezet. De schuifafsluiters mogen uitsluitend toegepast worden binnen de op het typeplaatje aangegeven specificaties. Wijzigingen zijn alleen toegestaan na overleg met de fabrikant of haar vertegenwoordiger. Deze magneetafsluiters van het schuiftype zijn ontworpen op het gebruik van gefilterde lucht of neutrale gassen. Overschrijd nooit de maximaal toegestane druk van de afsluiter = 10 bar (of 8 bar met een Piezotronic-stuurklep conform ATEX Ex ia). Zorg voor een minimale stuurdruk van 2 bar. Alleen vakkundig personeel mag de afsluiter installeren en onderhouden. • Standaard pneumatisch bediende versies in IP65-klasse of versies voor gebruik in explosiegevaarlijke omgevingen veroorzaakt door gassen, dampen, mist of stof volgens ATEX-richtlijn 94/9/EG. (De zoneclassificatie voor deze versies staat op het ATEX-label, zie E1). Veiligheidscode, serie 551: II 1 GD c T6 T85°C Ta -40°C tot +65°C. Veiligheidscode (553-serie): II 2 GD cT6 (T85°C) -T5 (T100°C) ALGEMENE INSTALLATIE- EN ONDERHOUDSINSTRUCTIES Magneetafsluiters uit de 551-serie met messing huis, of uit de 551-/553-serie met roestvaststalen huis, en voorzien van ¼”- of ½”-schroefdraad of een NAMUR-aansluiting - Plaats de 2 O-ringen (zie 9). - Plaats, indien nodig, de positioneerstift op de kop: • Op de 3/2 NC-functieplaat bevindt de centreeropening Ø 5 zich bij A1. • Op de 5/2-functieplaat bevindt de centreeropening Ø 5 zich bij A2. 3/2 NC 5/2 - 5/3 NL de uitlaatgassen op te vangen. Monteren / instellen (fig. 3a): Versie 3/2 NC = 1 uitlaatverloopstuk moet worden gemonteerd aan poort 3. Versie 5/2 = 2 uitlaatverloopstukken dienen te worden gemonteerd aan poorten 3 en 5 Duw de schroef (4) op het verloopstuk in het gat en schroef hem vast tot tegen de aanslag; draai hem vervolgens losser om de uitlaatstroom te verhogen (nooit meer dan twee slagen, max. doorstroom verkregen bij één slag). Draai de borgmoer (4a) vast met een sleutel van 13 mm. Voer een ruwe afstelling uit voordat de druk wordt aangebracht en voer een fijnafstelling uit na het onder druk brengen. PNEUMATISCHE AANSLUITING (fig. 3a, 3b, 13a en 13b) Afhankelijk van de versie (3/2 NC of 5/2), kunnen één of twee roestvaststalen uitlaatbeschermers worden gebruikt (zie fig. 2). • Aansluiting van de pneumatisch gestuurde versie: G 1/8 of NPT 1/8 of G 1/4 of NPT 1/4. • Aansluiting van de stuuruitlaten De uitlaatgassen kunnen worden opgevangen, afhankelijk van de gebruikte afsluiterversie. • Handmatige bediening Afhankelijk van de versie worden de producten geleverd met of zonder handmatige bediening om ook te werken zonder stroom. De handmatige bediening wordt aangegeven met het symbool ( ), in fig. 4, 5, 14, 15, 21 t/m 24, en zie 10 in fig. 3a, 3b, 13a, 13b. Het type handbediening, impulstype of van schakeltype (duw-/draaitype), wordt aangeduid door het symbool ( ) in fig. 3a, 3b, 13a en 13b. Beide typen maken stroomloze bediening mogelijk. MONTAGE ! ATEX 94/9/EG-versies: Zorg dat alle metalen en geleidende onderdelen altijd op elkaar zijn aangesloten en geaard zijn. Het afsluiterhuis is via de bevestigingsschroef (zie F) geaard. De afsluiters mogen in alle standen worden gemonteerd. Versies met schroefdraadaansluitingen ¼” (fig. 3a), ½” (fig. 3b): Monteer de afsluiter met behulp van twee bouten (zie 1) (niet bij levering inbegrepen). Versies met NAMUR-aansluiting (fig. 13a, 13b): Kies de gewenste werking voordat u de schuifafsluiter monteert: - Kies de functieplaat die correspondeert met de gewenste SPECIALE VOORWAARDEN VOOR VEILIG GEBRUIK functie : 3/2 NC of 5/2 (zie 1a of 1b). ATEX 94/9/EG-versies: De afsluiter moet worden geaard (zie - Zorg voor correcte plaatsing van de afdichting (zie.7) "Montage"). De maximale temperatuur van het medium mag de omge- - Monteer de functieplaat met behulp van de 2 meegeleverde bouten (zie 8) onder de schuifafsluiter. De functie-indicatie vingstemperatuur niet overschrijden. moet zich aan de retourzijde (codering) bevinden. Bewaar de schuifafsluiter in zijn originele verpakking zolang u ELEKTRISCHE AANSLUITING • Versie met magneetkoppen met ASCO-aansluiting: Zie de aanvullende installatie-instructies die bij elke magneetkop worden meegeleverd. IP65-magneetknop (fig. 3a, 3b en 13a, 13b): Monteer de eerst spoel op de buis (360° draaibaar) en daarna de losneembare ISO 4400/EN 175101-803A aansluiting (kabeldiam. 6-10 mm) draaibaar over 90° (3 pennen: 2 + aarde). • Versies met CNOMO-montageplaat: Zie de aanvullende installatie-instructies die worden geleverd met elke stuurklep. • Algemene aanbevelingen: ! Controleer vóór iedere inbedrijfstelling of de handDe elektrische aansluiting dient te gebeuren door een vakmatige bediening is teruggezet op diens gedeactiveerde man en in overeenstemming met de geldende voorschriften en normen. stand "0", teneinde elk risico op persoonlijk letsel en op Let op: beschadiging van de apparatuur te vermijden. - Voordat men aan het werk begint, moeten alle spanningvoerende delen spanningsloos worden gemaakt. • Aanpassing aan externe stuurvoorziening - Afhankelijk van de spanning moeten de elektrische com(fig.3a, 3b, 13a en 13b, zie 6) ponenten eventueel worden geaard volgens de lokaal • Algemene aanbevelingen voor pneumatische aansluigeldende wet- en regelgeving. tingen De meeste afsluiters zijn uitgerust met spoelen voor continu De leidingen moeten correct worden ondersteund en uitgebruik. Om elk risico op lichamelijk letsel te vermijden, dient gelijnd om elke mechanische belasting van de afsluiter te men aanraking van de magneetkop te voorkomen omdat vermijden. Bij het vastschroeven mag u de afsluiter niet die bij normaal gebruik heet kan worden. In voorkomende als hefboom gebruiken. Plaats gereedschappen zo dicht gevallen dient men de magneetkop af te schermen voor mogelijk bij de te maken verbinding. Gebruik een zodanig aanraking. koppel voor leidingverbindingen dat het product NIET WORDT BESCHADIGD. ONDERHOUD • Versies met schroefdraadaansluitingen ¼” (fig. 3a), ½” ! Voor de inbedrijfname en voordat u begint aan onder(fig. 3b): Aansluiten van de schuifafsluiter: houdswerk moet u de elektrische voeding uitschakelen en de Sluit de leidingen aan zoals aangegeven op het typeplaatje. afsluiter drukloos maken om elk risico op het ontstaan van - Werking 3/2 NC: persoonlijk letsel of materiële schade te vermijden. Drukinlaat via poort 1 (met ¼”- of ½”-schroefdraad). ATEX-versies: neem alle voorschriften conform de EuroDrukuitlaat via poort 2. pese richtlijn 99/92/EG en de hiervan afgeleide normen Uitlaat via poort 3 (met ¼”- of ½”-schroefdraad). strikt in acht. - Werking 5/2: • Reiniging Drukinlaat via poort 1. Drukuitlaat via de poorten 2 en 4. Hoeveel onderhoud de afsluiters vereisen, hangt af van de De uitlaten van de afsluiter worden naar de poorten 3 gebruiksomstandigheden. Zorg voor regelmatig onderhoud. en 5 geleid. Controleer tijdens het onderhoud of onderdelen zijn versleten. • Versies met NAMUR-aansluiting (fig 13a, 13b): Een reinigingsbeurt is nodig wanneer werkritme vertraagt Aansluiting van de schuifafsluiter: terwijl de stuurdruk correct is, of wanneer een abnormaal Sluit de leidingen aan zoals aangegeven op het typeplaatje. geluid of lek wordt waargenomen. - Werking 3/2 NC: • Geluidsniveau Drukinlaat via poort 1 (met ¼”- of ½”-schroefdraad). De geluidsemissie hangt sterk af van de toepassing, en Drukuitlaat via poort 2. van het gebruikte medium en de apparatuur. De bepaling Uitlaat via poort 3 (messing huis: 1/8 ; roestvaststalen van het geluidsniveau kan pas uitgevoerd worden nadat de huis: 1/4" of 1/2" schroefdraad). afsluiter is ingebouwd. De afsluiter leidt de uitlaat van de terugstelveerkamers • Preventief onderhoud bij enkelvoudige werking naar poort 3. We raden u aan Gebruik de afsluiter ten minste één keer per maand om om poort 5 (niet gebruikt) af te schermen, maar niet af de werking ervan te controleren. te sluiten. - In geval van problemen of als er onduidelijkheden tijdens - Werking 5/2: montage, gebruik of onderhoud optreden, neem dan conDrukinlaat via poort 1 (met ¼”- of ½”-schroefdraad). tact met ons op of met één van onze vertegenwoordigers. Drukuitlaat via de poorten 2 en 4. • Storingen verhelpen De afsluiter leidt de uitlaten naar de poorten 3 en 5 - Verkeerde uitlaatdruk: Controleer de druk aan de inlaat(messing huis: 1/8 ; roestvaststalen huis: 1/4" of 1/2" zijde van de afsluiter, deze moet overeenstemmen met schroefdraad). de specificaties op het typeplaatje. • Aansluiting van uitlaatverloopstukken (messing huis): Let op: zorg voor een minimale stuurdruk van 2 bar. Schuifafsluiters uit de serie 551 worden conform bestelling Controleer of de afsluiter correct werkt voordat u hem geleverd met of zonder 1/8" miniatuur-uitlaatverloopstukken, opnieuw in bedrijf stelt, om zo elk risico op lichamelijk achtervoegsel M (fig. 13a). letsel of materiële schade te vermijden. Deze instelbare mini-uitlaatverloopstukken worden gebruikt • Reserveonderdelen om de bedrijfssnelheid van de actuator aan te passen. Ze De spoel is verkrijgbaar als reserveonderdeel. kunnen ook worden aangesloten (1/8" schroefdraad) om Vervang zo nodig de gehele afsluiter. 12 13 BESCHRIJVING ATEX 94/9/EG-versies: Zie "Speciale voorwaarden voor veilig gebruik". Versies die geïsoleerd zijn van de buitenlucht: De inwendige delen van de afsluiter zijn geïsoleerd van de buitenlucht, voor bescherming in schadelijke omgevingen. Op alle uitlaatopeningen van deze schuifafsluiter kunnen leidingen worden aangesloten, zodat ze optimaal kunnen worden afgeschermd van hun omgeving en van het milieu. Daardoor zijn ze met name geschikt voor installaties in gevoelige omgevingen zoals in stofvrije ruimten, in de farmaceutische industrie en in de voedingsmiddelenindustrie. Bij gebruik in de buitenlucht en bij gebruik in veeleisende omgevingen (stof, dampen, enz.) moet u leidingen of appendages op de uitlaatpoorten aansluiten om de inwendige delen van de schuifafsluiter te beschermen. EG-typegoedkeuring nr. (serie 551): INERIS 03 ATEX 0219 X Dit product voldoet aan de Europese normen EN 13463-1 en EN 13463-5, en daarmee ook aan alle wettelijke arbovoorschriften. • Pneumatisch werkende magneetafsluiters met magneetkoppen: - IP65-klasse of gecertificeerd voor gebruik in explosiegevaarlijke omgeving volgens ATEX-richtlijn 94/9/EG. • Versies met magneetkoppen met ASCO-montageplaat - standaard IP65 of voor gebruik in een explosiegevaarlijke omgeving II 3D IP65/IP67 of ATEX Ex d, m, em, Ex ia (Serie 551: II 1G/2D Ex ia IIC IP65/IP67 of serie 553: II 2G/D Ex ia IIC IP65/IP67). • Versies met stuurkleppen met montageplaat CNOMO E06.05.80 (grootte 30) of CNOMO E06.36.120N (grootte 15) - standaard IP65 of stuurkleppen voor gebruik in explosiegevaarlijke omgevingen volgens ATEX Ex d of Ex ia. Let op (CNOMO-stuurkleppen): De zoneclassificatie (ATEX 1999/92/EG) wordt in eerste instantie bepaald door de vermelding op het typeplaatje fig. 10 en 20 (zie E1 of E2) op het huis van de afsluiter. Veiligheidscode volgens ATEX-richtlijn 94/9/EG: II 1 GD c T6 T85°C Ta -40°C tot +65°C EG-typegoedkeuring certificaat-nr.: INERIS 03 ATEX 0219 X Neem bij het monteren van dit product op een stuurklep volgens ATEX 94/9/EG de minst gunstige categorie, maximale werkdruk en temperatuur in acht. Dit product voldoet aan de Europese normen EN 13463-1 en EN 13463-5, en daarmee ook aan alle wettelijke arbo-voorschriften. Neem de montagerichting voor de stuurkleppen zoals aangeduid in figuren 4/5/14/15/21/22/23/24 in acht, evenals de genoemde aandraaimomenten. Neem bij magneetkoppen en stuurkleppen die voldoen aan ATEX 49/9/EG altijd de gebruiksvoorschriften in acht die in de handleiding van het product staan vermeld. 3834901 3834901 INSTALLASJONS- OG VEDLIKEHOLDSINSTRUKSER Serie 551 magnetventiler, messinghus, eller serie 551-553, hus av rustfritt stål, ¼“, ½" gjenger eller NAMUR-grensesnitt BESKRIVELSE AV GODKJENNELSEN Versjoner som godkjennelsen gjelder (fig. 1 og 11): Kun hus av messing (serie 551) eller rustfritt stål (serie 551, 553), monostabil (fjærretur) eller bistabil, 3/2 NC (normalt lukket) funksjon eller 5/2, versjon isolert fra den utvendige atmosfæren. Versjoner uten manuell overstyring eller med manuell overstyring av impulstypen: - med gjengede 1/4 (551) eller 1/2 (553) porter - 551, med 1/4" gjenget kobling, maks. portdybde 11,5 mm. (Ikke koble trykktilførselen til utblåsningsåpning 3. Den “miljøvennlige” konstruksjonen er ikke tilpasset en “distribusjons”-funksjon eller bruk i NO-funksjon. Ta kontakt med oss for funksjon tilgjengelig i spesifikke c-versjoner). - med NAMUR-grensesnit for direkte montering på enkeltløps (funksjon 3/2 NC) eller dobbeltløps (funksjon 5/2) trykkluftsregulatorer. Ventilens funksjon kan konverteres fra 3/2 NC til 5/2 ved å montere den medfølgende 13/2 NC eller 5/2 grensesnittplaten på bunnen av ventilen (fig. 13a, 13b, ref 1a og 1b). 551, Max. 1/4", maks. portdybde 11,5 mm. (Ikke koble trykktilførselen til utblåsningsåpning 3. Den “miljøvennlige” konstruksjonen er ikke tilpasset NOfunksjon. Ta kontakt med oss for funksjon tilgjengelig i spesifikke c-versjoner). - Kobling av rør for de påkrevde funksjonene må skje i samsvar med denne dokumentasjonen og portmerkene på produktet. - For å forhindre blokkering av ventilfunksjonen må du sørge for at det ikke kommer fremmedlegemer inn i kretsen. Bruk av tetningstape eller tetningsmiddel bør begrenses til et minimum. - Disse ventilene er beregnet for bruk i forbindelse med ren og tørr luft eller uvirksom (inert) gass. Anbefalt minimumsfiltrering: 50 mikron. Væskens duggpunkt må være minst -10°C (18°F) lavere enn minstetemperaturen som væsken kan bli eksponert for. Når det brukes oljeholdig luft, må smøremiddelet være kompatibelt med elastomerene (elastiske kunststoffer) som benyttes. Instrumentluft som er i samsvar med ANSI/ISA-standard S7.3 (1975) overskrider de nødvendige kravene og er derfor en akseptabel væske for disse ventilene. Alle utblåsningsporter på ventilene og pilotene må ! være beskyttet med utblåsningsvern av rustfritt stål. Disse utblåsningsvernene kobles til port 3 (3/2 NC) eller port 3 - 5 /5/2). Når de brukes utendørs, eller oppbevares i lange perioder og/eller når de eksponeres for strenge miljøer (støv, væsker osv.) må det brukes utblåsningsvern. Påliteligheten til ventilene kan ikke garanteres hvis det brukes et annet utblåsingsvern enn det som følger med produktet. - Tillatt temperaturområde: -40°C til +80°C (serie 551); -40°C til +60°C (serie 553). - Maksimalt arbeidstrykk: - 2 til 10 bar - 2 til 8 bar (ISSC/PISC/PISCIS/CFSCIS/CFSDIS/CFVTIS) BESKRIVELSE ATEX 94/9/EC-versjoner: Se "Spesielle vilkår for sikker bruk". Versjoner som er isolert fra atmosfæren: De interne delene av ventilen er isolert fra atmosfæren utenfor for å gi vern i aggressive miljøer. Alle utblåsningsporter på spoleventilen kan utstyres med rør, noe som gir bedre miljøvern og anbefales spesielt i følsomme områder som renrom og til bruk i farmasøytisk og matforedlende industri. Det er nødvendig å koble rør eller armatur til utblåsningsportene for å beskytte interne deler i spoleventilen hvis den brukes utendørs eller under vanskelige forhold (støv, væsker osv.). SPESIELLE VILKÅR FOR SIKKER BRUK ATEX 94/9/EC-versjoner: Ventilen må jordes (se "Montasje") Den maksimale væsketemperaturen må ikke være høyere enn romtemperaturen. Spoleventilen må oppbevares i sin opprinnelige innpakning så lenge den ikke brukes. Vernedekslene må ikke fjernes fra tilkoblingsportene og spoleoperatørene. Lagringsbetingelser: Beskyttet mot vær; oppbevaringstemperatur: -40 °C til +70 °C; relativ luftfuktighet: 95 % Etter lagring i lav temperatur må spoleventilene gradvis bringes til driftstemperatur før de settes under trykk. 3/2 NC 5/2 - 5/3 NO Spoleventilene er beregnet for bruk innenfor de tekniske spesifikasjoner som er angitt på navneplaten. Endringer av produktene må kun gjøres etter rådføring med produsenten eller hans representant. Disse spoleventilene er beregnet til bruk i forbindelse med filtrert luft eller naturgass. Ventilens største tillatte trykk må ikke overskrides = 10 bar (eller 8 bar med en Piezotronic pilotventil til ATEX Ex ia). Du må overholde minimumsverdien for styreventilen på 2 bar. Installasjon og vedlikehold av ventilen må kun utføres av kvalifisert personale. • Standard IP65-klassifiserte luftdrevne versjoner eller versjoner for bruk i eksplosive atmosfærer forårsaket av gass, damp, dis eller støv i henhold til ATEX-direktiv 94/9/ EC. (Soneklassifiseringen for denne versjonen er angitt på ATEX-merket, se E1). Sikkerhetskode, serie 551: II 1 GD c T6 T85°C Ta -40°C til +65°C. Sikkerhetskode, serie 553: II 2 GD cT6 (T85°C) -T5 (T100°C). EC typeundersøkelse sertifikatnr. (serie 551): INERIS 03 ATEX 0219 X Samsvar med de vesentlige helse- og sikkerhetskravene er sikret gjennom samsvar med de europeiske standardene EN 13463-1 og EN 13463-5. • Spole-luft-drevne versjoner utstyrt med spoleoperatører: - IP65-forseglet eller - sertifisert for bruk i eksplosive atmosfærer i henhold til ATEX-direktiv 94/9/EC • Versjoner med spoleoperatører med ASCO monteringspute, - IP65-klassifisert som standard, eller for bruk i eksplosive atmosfærer II 3D IP65/IP67 eller ATEX Ex d, m, em, Ex ia (serie 551: II 1G/2D Ex ia IIC IP65/IP67 eller serie 553: II 2G/D Ex ia IIC IP65/IP67). • Versjoner med styreventiler med CNOMO E06.05.80 (størrelse 30) eller CNOMO E06.36.120N (størrelse 15) monteringspute, - IP 65-klassifisert som standard, eller montering av styreventiler for bruk i eksplosive atmosfærer i h.h.t. ATEX Ex d eller EEx ia. Advarsel (CNOMO-styreventiler): Soneklassifiseringen (ATEX 1999/927EC) er i hovedsak definert av indikasjonene på navneskiltet fig. 10 og 20 (ref. E1 eller E2) på ventilhuset. Sikkerhetskode i henhold til ATEX-direktiv 94/9/EC: II 1GD c T6 T85°C Ta -40°C til +65°C EC typeundersøkelse sertifikatnr.: INERIS 03 ATEX 0219 X Når dette produktet settes sammen med en styreventil i henhold til ATEX 94/9/EC, må du regne ut fra den minst fordelaktige kategorien, Maksimalt arbeidstrykk og temperaturen. Samsvar med de vesentlige helse- og sikkerhetskravene er sikret gjennom samsvar med de europeiske standardene EN 13463-1 og EN 13463-5. Monteringsstillingene for styreventiler som vist i figur 4/5/14/15/21/22/23/24 og de indikerte strammemomentene må etterfølges. Når det gjelder spoleoperatører og styreventiler i henhold til ATEX 49/9/EC, må man strengt holde seg til bruksanvisningen gitt i de spesifikke installasjonsinstruksene som kommer sammen med produktet. MONTERING ! ATEX 94/9/EC-versjoner: Sørg for at alle metall- eller ledende deler alltid er innbyrdes tilsluttet og jordet.Ventilhuset er jordet med festeskruen (se F). Ventilene kan monteres i en hvilken som helst stilling. Versjoner med gjengede porter 1/4 (fig 3a), 1/2 (fig 3b): Monter ventilen med to skruer (se 1) (følger ikke med). Versioner med NAMUR-grensesnitt (fig. 13a, 13b): Før spoleventilen monteres på styringen, må den innstilles for den påkrevde funksjon: - Velg det grensesnittet som korresponderer med den påkrevde funksjon: 3/2 NC eller 5/2 (se 1a eller 1b). - Påse at pakningen er riktig tilpasset (se 7). - Monter grensesnittet under spoleventilen med de to medfølgende skruene (se 8). Påse at indikeringen for funksjonen befinner seg på retursiden (polariseringssporet). - Sett inn de to O-ringene (se 9). 14 3834901 INSTALLASJONS- OG VEDLIKEHOLDSINSTRUKSER Serie 551 magnetventiler, messinghus, eller serie 551-553, hus av rustfritt stål, ¼“, ½" gjenger eller NAMUR-grensesnitt - Om nødvendig, sett styrepinnen på styringen: • På 3/2 NC-funksjonsplaten: Ø 5-hullet er ved A1. • På 5/2-funksjonsplaten: Ø 5-hullet er ved A2. 3/2 NC 5/2 - 5/3 NO Montasje / Justering (fig. 3a) Versjon 3/2 NC = 1 utblåsingsreduksjonsmuffe settes på port 3 Versjon 5/2 = 2 utblåsingsreduksjonsmuffe settes på port 3 og 5 Sett skruen (4) på reduksjonsmuffen i hullet og skru den til den stopper. Skru den deretter ut for å øke utblåsingsflyten (aldri mer enn to omdreininger, maks. flyt oppnås ved én omdreining). Stram til låsemutteren (4a) med en 13 mm nøkkel. Foreta en grovjustering før den settes under trykk og finjuster etterpå. TRYKKLUFTKOPLING (fig. 3a, 3b, 13a OG 13b) Avhengig av versjonen (3/2 NC eller 5/2) kan ett eller begge utblåsningsvern av rustfritt stål brukes (se fig. 2). • Tilkobling av versjon med luftstyring: G 1/8 eller NPT 1/8 eller G 1/4 eller NPT 1/4. • Tilkobling av styreventilens utblåsninger Utblåsingene kan samles inn i henhold til versjonen som brukes. • Manuell overstyring ELEKTRISK TILKOBLING Avhengig av versjon, leveres produktene uten manuell overstyring eller med manuell overstyring av impulsty- • Versjon uten spolehoder med ASCO-grensesnitt: Se ytterligere installasjonsinstrukser som følger med hvert spopen for drift uten strøm. Den manuelle oversgtyringen er lehode. angitt med symbolet( ) på fig. 4, 5, 14, 15, 21 til 24 og ref. 10 på fig. 3a, 3b, 13a, 13b. IP65-merket spoleoperatør (fig. 3a, 3b og 13a, 13b): Sett Operatør av pulstypen eller vedlikeholdt (trykk/drei-type) spolen på røret (kan roteres gjennom 360°) og deretter manuell overstyring angis med symbolet ( ) på fig. 3a, 3b, den fjernbare ISO 4400/EN 175101-803A-konnektoren 13a og 13b tillater bruk uten strøm. (kabel dia 6-10 mm) som kan roteres 90° (3 pinner: 2 + jord). ! Før bruk må den manuelle overstyringen være satt i utkoblet stilling "0" for å forhindre risiko for personskade • Versjon med CNMO monteringspute: eller skade på utstyret. Se ytterligere monteringsinstruks som følger med hver styre• Tilpasning til ekstern pilottilførsel ventil. (fig.3a, 3b, 13a et 13b, ref. 6) • Generelle anbefalinger: • Generelle anbefalinger for tilkobling av trykkluft Elektriske koblinger må gjøres av kvalifisert personell og i Koble rør for de påkrevde funksjonene i samsvar med denne henhold til gjeldende lokale standarder og forskrifter. dokumentasjonen og portmerkene på produktet. Forsiktig: Sørg for at det ikke kommer fremmedlegemer inn i systemet. - Før eventuelle inngrep må du slå av strømmen slik at Rørene må støttes og justeres for å forhindre mekanisk komponentene slås av. belastning på ventilen. Når du strammer må du ikke bruke - Avhengig av spenningen må elektriske komponenter være ventilen som brekkstang. Sett skrunøkler så nær tilkobjordet i henhold til lokale standarder og forskrifter. lingspunktet som mulig. For å unngå skade på utstyret må De fleste ventiler er utstyrt med spoler beregnet på kontinuerlig drift. For å redusere risikoen for personskade må rørkoblingene IKKE TREKKES TIL FOR STRAMT. man ikke berøre spoleoperatøren, som kan bli varm under • Versjoner med gjengede porter 1/4 (fig 3a), 1/2 (fig 3b): normale driftsforhold. Hvis ventilen er lett tilgjengelig, må Tilkopling av spoleventil: installatøren sette opp vern som forhindrer tilfeldig kontakt Koble rørene til som anvist på merket: med spoleoperatøren. VEDLIKEHOLD ! Før eventuelt vedlikeholdsarbeid eller før ventilen settes i drift, skal den slås av, trykket skal tas ut og ventilen ventileres for å redusere risikoen for skade på personer eller utstyr. ATEX-versjoner: Alle prosedyrer anbefalt av Alle prosedyrer som anbefales av direktiv 99/92/EC og tilknyttede standarder må følges nøye. - 3/2 NC-funksjon: Trykkinntak gjennom port 1 (1/4” eller ½” gjenger). Trykkutgang gjennom port 2. Utblåsning gjennom port 3 (1/4” eller 1/2” gjenger). - 5/2-funksjon: Trykkinntak gjennom port 1. Trykkutgang gjennom port 2 og 4. Utblåsning kanaliseres gjennom ventilen til port 3 og 5. • Rengjøring Vedlikehold av ventilene avhenger av driftsforholdene. De • Versjon med NAMUR-grensesnitt (fig. 13a,13b): må rengjøres regelmessig. Under service bør komponentene kontrolleres for graden av slitasje. Komponentene må Tilkobling av spoleventilen: Kople rørene som vist på merkelappen: rengjøres når man merker en nedgang i takten, selv om - 3/2 NC-funksjon: trykket i styreventilen er korrekt, eller hvis det oppdages Trykkinntak gjennom port 1 (1/4” eller ½” gjenger). Trykkutgang uvanlig støy eller det oppstår lekkasje. gjennom port 2.(messinghus: 1/8; hus av rustfritt stål: 1/4" eller • Støy 1/2" gjenger) Støynivået avhenger av bruksområdet, mediet og typen Utslipp fra returstyringens fjærkamre i den enkeltvirkende utstyr som brukes. Nøyaktig fastsettelse av støynivået kan versjonen, er kanalisert gjennom ventilen til 1/8 " port 3. Det bare gjøres av brukeren som har ventilen installert i sitt anbefales å beskytte port 5 (dersom den ikke er i bruk) - tilsystem. stoppe den ikke. • Forebyggende vedlikehold - Bruk ventilen minst én gang i måneden for å kontrollere - 5/2-funksjon: funksjonaliteten. Trykkinntak gjennom port 1 (1/4” eller ½” gjenger). Tryk- Hvis det oppstår problemer under vedlikehold eller hvis du er kutgang ved port 2 og 4. i tvil, vennligst ta kontakt med oss eller en av våre autoriserte representanter. Utslippene er kanalisert gjennom ventilen til portene 3 • Feilsøking - Feil utgangstrykk: Kontroller trykket på ventilens tilførselsog 5 (messinghus: 1/8; hus av rustfritt stål: 1/4" eller 1/2" side. Det må tilsvare verdiene som fremgår av navneplaten. gjenger). Forsiktig: du må overholde minimumsverdien for styreventilen på • Tilkobling av utblåsingsreduksjonsmuffe (hus av mes2 bar. sing) For å unngå skade på personer eller utstyr må du kontrollere at ventilen fungerer som den skal før du setter den Serie 551 spoleventiler leveres som bestilt med eller uten 1/8” ublåsingsreduksjonsmuffer, suffiks M (fig. 13a). tilbake i bruk. Disse justerbare miniutblåsingsreduksjonsmuffene brukes • Reservedeler Spoler er tilgjengelige som reservedeler. til å justere regulatorens driftshastighet. De kan også kobles Hvis nødvendig, skifter du ut hele ventilen. til (1/8 gjenger) for å samle utblåsingene. 15 3834901 INSTALLATIONS- OCH UNDERHÅLLSINSTRUKTIONER Serie 551 magnetventiler, mässingskropp, eller serie 551-553, rostfri stålkropp, ¼", ½" gänga eller NAMUR-koppling 3/2 NC 5/2 - 5/3 SE och solenoidoperatörerna sitta kvar. Förvaringsförhållanden: inomhus; förvaringstemperatur: -40 C - +70°C; relativ fuktighet: 95 % Efter kall förvaring måste rundslidsventilen gradvis värmas upp till arbetstemperatur innan den sätts under tryck. Rundslidsventilerna är avsedda för att användas i enlighet med de tekniska egenskaper som står angivna på namnplattan. Modifikationer av produkterna är enbart tillåtet med medgivande från tillverkaren eller auktoriserad representant. - med gängade portar 1/4 (551) eller 1/2 (553) - 551, med ¼” De här solenoidrundslidsventilerna är konstruerade för gjenget kobling, maks. portdybde 11,5 mm. (Anslut inte att användas med filtrerad luft eller neutral gas. Ventilens tryckkopplingen till utgångsport 3. Den “miljöskyddande” maximalt tillåtna tryck får inte överskridas = 10 bar (eller 8 bar konstruktionen är inte anpassad för en “distribuerande” med en Piezotronic pilotventil med ATEX Ex ia). Observera funktion eller använd NO-funktionen. Kontakta oss för minimum pilottryck på 2 bar. Installation och underhåll av mer om vilka funktioner som är tillgängliga för specifika ventilen får enbart utföras av behörig personal. versioner). • Standard IP65-märkta luftstyrda versioner eller versioner för användning i explosiva atmosfärer som uppstår genom - med NAMUR-koppling för direkt montering till enkelverkande gaser, ånga, dimma eller damm enligt ATEX-direktiv 94/9/ (funktion 3/2 NC) eller dubbelverkande (funktion 5/2) pneuEC. (Zonklassificeringen för den här versionen anges på matiska ställdon. Ventilens funktion kan konverteras från 3/2 ATEX-etiketten, ref E1). NC till 5/2 genom att montera medlevererad 13/2 NC eller Skyddskod, serie 551: II 1 GD c T6 T85°C Ta -40°C till +65°C. 5/2 kopplingsplatta underst på ventilen (fig. 13a, 13b, ref. 1a Säkerhetskod, serie 553: II 2 GD c T6 (T85°C) - T5 (T100°C). och 1b). 551, 1/4”, maks. portdybde 11,5 mm. (Anslut inte EC-typ provningscertifikat nr. (Serie 551): tryckkopplingen till utgångsport 3. Den “miljöskyddande” konstruktionen är inte anpassad för NO-funktion. Kontakta INERIS 03 ATEX 0219 X oss för mer om vilka funktioner som är tillgängliga för Uppfyllande av Grundläggande Hälso- och Säkerhetskrav försäkras genom överensstämmelse med Europeiska Normer specifika versioner). - Anslut ledningarna för de önskade funktionerna enligt inEN 13463-1 och EN 13463-5. struktionerna i den här dokumentationen och portmärkningen på produkten. • luftstyrda solenoidversioner med solenoidoperatörer: - Se till att inga främmande material som kan blockera - IP65 tätad eller ventilfunktionen kommer in i systemet. Försök att hålla an- certifierad för användning i explosiva atmosfärer i enlighet vändningen av tätningstejp eller andra tätningsmaterial ett med ATEX direktiv 94/9/EC minimum. - De här ventilerna är avsedda för användning med en ren och • Versioner med solenoidoperatörer med ASCO montetorr luft eller ädelgas. Rekommenderad minimum filtrering: ringsplatta, 50 mikron. Daggpunkten för vätskan som används måste - IP65-märkt som standard eller för användning i explosiva vara minst -10°C (18°F) under den minimumtemperatur atmosfärer II 3D IP65/IP67 eller ATEX Ex d, m, em, Ex ia som vätskan får utsättas för. Vid användning av smord luft (Serie 551: II 1G/2D Ex ia IIC IP65/IP67 eller serie 553: II 2G/D Ex ia IIC IP65/IP67). måste smörjmedlet vara förenligt med de elaster som används. Pneumatisk luft i överensstämmelse med ANSI/ISA standard S7.3 (1975) överskrider nödvändiga krav och är • Versioner med piloter med CNOMO E06.05.80 (storlek 30) därför en godkänd vätska för dessa ventiler. eller CNOMO E06.36.120N (storlek 15) monteringsplatta, - IP 65-märkt som standard eller monterad med piloter för Alla utgångsportar från ventiler och styrventiler användning i explosiva atmosfärer i enlighet med ATEX Ex ! måste skyddas med de rostfria utgångsskydden. d eller EEx ia. Koppla utblåsskydden på port 3 (3/2 NC) eller port 3 Varsamhet (CNOMO-piloter): Zonklassificeringen (ATEX - 5 (5/2). Utblåsskydd skall användas vid tillämpningar 1999/927EC) definieras huvudsakligen av vad som utomhus eller vid förvaring under längre tid, och/eller anges på typskylten fig. 10 och 20 (ref. E1 eller E2) på när de utsätts för svåra omgivningar (damm, vätskor etc.). ventilkroppen. Skyddskod enligt ATEX-direktivet 94/9/ Ventilens tillförlitlighet kan inte garanteras när ett annat EC: II 1 GD c T6 T85°C Ta -40°C till +65°C än det medlevererade utblåsskyddet används. Certifikatnr för EC typundersökning: INERIS 03 ATEX 0219 X - Tillåtet temperaturområde: -40°C till +80°C (serie 551); -40°C till +60°C (serie 553). Ta hänsyn till den minst gynnsamma kategorin, maximum - Maximum arbetstryck: arbetstryck och temperaturen vid montering av den här - 2 - 10 bar produkten till en pilot till ATEX 94/9/EC. Uppfyllande av - 2 - 8 bar (ISSC/PISC/PISCIS/CFSCIS/CFSDIS/CFVTIS) Grundläggande Hälso- och Säkerhetskrav försäkras genom överensstämmelse med Europeiska Normer EN 13463-1 BESKRIVNING och EN 13463-5. Styrventilernas monteringsposition såsom ATEX 94/9/EC-versioner: Se "Särskilda förhållanden för säker visas i figurerna 4/5/14/15/21/22/23/24 och de angivna åtanvändning". dragningsmomenten måste iakttas. Versioner som är isolerade från atmosfären: Ventilens invändiga delar är isolerade från atomsfären utanför och skyddas För solenoidoperatörer och piloter till ATEX 49/9/EC, ska därför vid användning i aggressiva miljöer. Alla utgångsportar användarinstruktionerna i motsvarande Installationsinpå rundslidsventilen kan förses med rörförbindning, vilket struktioner som medföljer produkten, strikt följas. ger bättre miljöskydd och rekommenderas särskilt i känsliga omgivningar såsom i "rena rum" och för tillämpning inom läMONTERING ! ATEX 94/9/EC-versioner: Se till att alla metalldelar eller kemedels- och livsmedelsindustrin. Vid användning utomhus eller i krävande miljöer (damm, vätskor o dyl) är nödvändigt ledande delar alltid är sammankopplade och jordade. Venatt ansluta ledningar eller fixturer till utgångsportarna för att tilstommen är jordad via fästskruven (ref F). skydda rundslidsventilens invändiga delar. Ventilerna kan monteras i valfri position. BESKRIVNING AV GODKÄNNANDET Utföranden som berörs av godkännandet (fig. 1 och 11): Ventilkropp av mässing (serie 551) eller rostfritt stål (serie 551, 553), monostabil (fjäderretur) eller bistabil, 3/2 NCfunktion (normalt stängd) eller 5/2, version isolerad från den omgivande atmosfären. Utföranden utan manuell företrädesstyrning eller med manuell företrädesstyrning av impulstyp: SÄRSKILDA FÖRHÅLLANDEN FÖR SÄKER ANVÄNDNING ATEX 94/9/EC-versioner: Ventilen ska anslutas till jord (se "Montera"). Den maximalt tillåtna vätsketemperaturen får inte överstiga omgivningstemperaturen. Rundslidsventilen ska förvaras i originalförpackningen så länge den inte används. Låt skydden på anslutningsportarna Versioner med gängade portar 1/4 (fig 3a), 1/2 (fig 3b): Montera ventilen med två skruvar (ref 1) (ingår ej). Versioner med NAMUR-koppling (fig. 13a, 13b): Innan rundslidsventilen monteras på operatören måste den först ställas in på önskad funktion: - Välj den anslutningstyp som överensstämmer med önskad 16 3834901 INSTALLATIONS- OCH UNDERHÅLLSINSTRUKTIONER Serie 551 magnetventiler, mässingskropp, eller serie 551-553, rostfri stålkropp, ¼", ½" gänga eller NAMUR-koppling funktion: 3/2 NC eller 5/2 (rep.1a eller 1b). - Se till att packningen monteras korrekt (rep.7). - Montera anslutningen under rundslidsventilen med de två medlevererade skruvarna (rep.8). Se till att funktionsindikeringen placeras på retursidan (polariseringsöppning). - Placera de två O-ringarna (rep.9). - Om nödvändigt, montera låspinnen på operatören: • På 3/2 NC funktionsplatta: Ø 5 dia. är hål A1. • På 5/2 funktionsplatta: Ø 5 dia. är hål A2. 3/2 NC 5/2 - 5/3 SE De justerande mini utblåsreducerarna används för att anpassa ställdonets arbetshastighet. De kan också kopplas (1/8 gänga) för att hantera utblåsluften. Montering / Justering (fig. 3a): Version 3/2 NC = 1 utblåsreducerare som kopplas till port 3 Version 5/2 NC = 2 utblåsreducerare som kopplas till port 3 och 5 Sätt i skruven (4) på reduceraren i hålet och skruva fast den helt; öppna sedan skruven för att öka utblåsflödet (dock aldrig mer än två slag, max. flöde erhålls vid ett varv). Spänn fast låsmuttern (4a) med en 13 mm nyckel. Grovinställ innan trycket slås på och finjustera när trycket är på. PNEUMATISK ANSLUTNING (fig. 3a, 3b, 13a och 13b): Beroende3 på versionen (3/2 NC eller 5/2) kan en eller båda utgångsskydden av rostfritt stål användas (se fig. 2). • Ansluta pneumatisk pilotutförande: G 1/8 eller NPT 1/8 eller G 1/4 eller NPT 1/4. ELEKTRISK ANSLUTNING • Ansluta pilotutblås • Utförande med magnethuvud med ASCO-koppling: Läs installationsinstruktionerna som levereras med resUtblåsluften kan hanteras enligt den version som används. • Manuell företrädesstyrning pektive magnethuvud. Beroende på utförandet, levereras produkten utan manuell IP65-klass megnhetreglage (fig. 3a, 3b och 13a, 13b): företrädesstyrning eller med manuell företrädesstyrning Montera spolen på röret (vridbar 360°) och sedan den av impulstyp för strömlös operation: Det manuella nödreglaget löstagbara ISO 4400/EN 175101-803A kontakten (kabelanges med symbolen ( ) i fig. 4, 5, 14, 15, 21 till 24, och ref. diam. 6-10 mm) vridbar 90° (3 stift: 2 + jord). 10 i fig. 3a, 3b, 13a, 13b. • Utförande med CNOMO plattmontage: Det manuella nödreglaget av impulstyp eller bibehållen typ Läs installationsinstruktionerna som levereras med res(tryck/vrid), angivet med symbolen ( )i fig. 3a, 3b, 13a och pektive pilotventil. 13b möjliggör körning utan kraft. • Allmänna rekommendationer: Elektriska anslutningar ska utföras av behörig tekniker och ! Se till att den manuella företrädesstyrningen står i enlighet med lokala normer och regler. i tillbakaläget "0" för att förebygga risk för person och Varsamhet: - Innan något utförs ska all strömförsörjning till komponenmaterialskada. terna kopplas bort. • Anpassning till extern styrmatning - Beroende på strömstyrka ska elektriska komponenter (fig. 3a, 3b, 13a och 13b, ref. 6) jordas enligt lokala normer och regler. • Allmänna rekommendationer för pneumatiska anslutDe flesta ventiler har spolar som konstruerats för konningar tinuerlig drift. För att förebygga personskador, vidrör Anslut ledningarna för den önskade funktionen enligt instrukinte solenoidoperatören som kan bli mycket varm under tionerna i den här dokumentationen och portmärkningen normala driftförhållanden. Om solenoidventilen är lätt att på produkten. komma åt ska installatören förse med lämpligt skydd för Se till att inga främmande material kommer in i systemet. att förekomma oavsiktlig kontakt. För att förebygga mekanisk belastning på ventilen är det viktigt att ledningarna har tillräckligt med stöd och är riktade UNDERHÅLL korrekt. Använd inte själva ventilen för åtdragningen, placera ! För att förebygga maskin- och personskada ska momentnyckeln så nära anslutningspunkten som möjligt. Var rädd om verktygen, DRA INTE ÅT kopplingarna FÖR strömförsörjning och tryck ska vara bortkopplat och ventilen luftas innan underhåll eller driftsättning utförs. HÅRT. ATEX-versioner: Följ strängt alla procedurer rekommen• Versioner med gängade portar 1/4 (fig 3a), 1/2 (fig 3b): derade i Direktivet 99/92/EC och tillhörande normer. Ansluta rundslidsventilen: Anslut ledningarna enligt etiketten: • Rengöring - 3/2 NC-funktion: Underhållet av ventilerna är beroende på driftförhållandena. Tryckingång vid port 1 (1/4” eller 1/2” gänga).Tryckutgång De ska rengöras med regelbundna intervaller. Vid service vid port 2. ska komponenterna kontrolleras på överdrivet slitage. Det Utgång vid port 3 (1/4” eller 1/2” gänga). är dags att rengöra komponenterna när arbetscyklerna går - 5/2-funktion: långsammare trots att pilottrycket är rätt eller när ovanliga Tryckintag vid port 1. Tryckuttag vid port 2 och 4. ljud eller läckage uppstår. Utblåsningen kanaliseras via ventilerna till port 3 och 5. • Buller • Utförande med NAMUR-koppling (fig 13a, 13b): Bullernivån är beroende på tillämpningen, medium och Ansluta rundslidsventilen: typen av utrustning som används. En korrekt mätning av Anslut ledningarna enligt etiketten: bullernivån kan enbart utföras hos användaren där ventilen installerats i ett system. - 3/2 NC-funktion: Tryckingång vid port 1 (1/4” eller 1/2” gänga).Tryckutgång • Förebyggande underhåll vid port 2. - Driftsätt ventilen minst en gång i månaden för att kontrolUtblås vid port 3 (mässingskropp: 1/8 ; rostfri stålkropp: lera att den fungerar som den ska. 1/4" eller 1/2" - Om problem uppstår vid underhåll eller vid tvivel, var god kontakta oss eller ett av våra auktoriserade ombud. Utblåset från returstyrda fjäderkammare i den enkelverkande versionen kanaliseras via ventil port 3. Vi rekommenderar att skydda port 5 (om oanvänd) - plugga inte • Problemlösning till det. - Inkorrekt utgångstryck: Kontrollera trycket på ventilens matarsida som ska korrespondera med värdena på namnplattan. - 5/2-funktion: Varsamhet: observera att minimalt pilottryck är 2 bar. Tryckingång vid port 1 (1/4” eller 1/2” gänga). För att förebygga person- och maskinskada, kontrollera Utblåsningen kanaliseras via ventilerna till port 3 och att ventilen fungerar korrekt innan den sätts i drift igen. 5 (mässingskropp: 1/8 ; rostfri stålkropp: 1/4" eller 1/2" gänga). • Reservdelar • Koppla utblåsreducerare (mässingkropp): Spolar kan beställas som reservdel. Om nödvändigt, byt ut hela ventilen. Serie 551 spolventiler levereras enligt order med eller utan miniatyr 1/8” utgångsreuktorer, suffix M (fig. 13a). 17 3834901 ASENNUS- JA HUOLTO-OHJEET Sarjan 551 solenoidiventtiilit, joissa messinkirunko, tai sarjojen 551–553 venttiilit, joissa ruostumaton teräsrunko, ¼”:n tai ½”:n kierteet tai NAMUR-liitäntä HYVÄKSYNTÄTIEDOT Hyväksyntä koskee seuraavia versioita (kuvat 1 ja 11): Messinkirunko (sarja 551) tai ruostumaton teräsrunko (sarjat 551, 553), yksiasentoinen (jousipalaute) tai kaksiasentoinen, 3/2 NC -toiminen (yleensä kiinni) tai 5/2-toiminen versio, joka on eristetty ympäröivästä ilmasta. Versioita, joissa ei ole käsitoimista ohitusta tai joissa on impulssityyppinen käsitoiminen ohitus ja: - 1/4”:n (551) tai 1/2”:n (553) kierreaukot - 551, jossa ¼” kierteellinen liitäntä, aukon maks. syvyys 11,5 mm. (Älä yhdistä paineen syöttöä poistoaukko 3:een. ”Ympäristösuojattua” rakennetta ei ole sovitettu ”jakelu”-toimintoon tai käytä EI-toimintona. Kysy meiltä erikoisversioissa käytettävissä olevista toiminnoista). 3/2 NC 5/2 - 5/3 FI Kun karaventtiilejä on säilytetty alhaisessa lämpötilassa, ne on vähitellen saatettava käyttölämpötilaan ennen paineistamista. Karaventtiilit on tarkoitettu käytettäväksi tyyppikilvessä määriteltyjen teknisten ominaisuuksien mukaisesti.Tuotteisiin saa tehdä muutoksia vain valmistajan tai valmistajan edustajan luvalla. Nämä magneettitoimiset karaventtiilit on suunniteltu käytettäväksi suodatetun ilman tai neutraalin kaasun kanssa. Älä yritä venttiilin suurinta sallittua painetta = 10 baaria (tai Piezotronic-ohjausventtiilillä 8 baaria ATEX Ex ia -standardin mukaisesti). Huomioi, että minimiohjauspaine on 2 baaria. Venttiilin asennuksen ja huollon saavat suorittaa vain valtuutetut henkilöt. • Standardinmukaiset IP65-luokan ilmatoimiset versiot tai versiot, jotka on suunniteltu käytettäväksi kaasua, höyryä, sumua tai pölyä sisältävissä räjähdysvaarallisissa tiloissa ATEX 94/9/EY -direktiivin mukaisesti. (Tämän version alueluokitus ilmoitetaan ATEX-merkinnän kohdassa liite E1). Turvakoodi, sarja 551: II 1GD c T6 T85 °C Ta –40 °C...+65 °C Turvakoodi, sarja 553: II 2 GD c T6 (T85°C) - T5 (T100°C). EY-tyyppitarkastustodistus nro (sarja 551): INERIS 03 ATEX 0219 X Yhteensopivuus terveys- ja turvavaatimusten kanssa on varmistettu noudattamalla EY-standardeja EN 13463-1 ja EN 13463-5. • Magneetti-ilmatoimiset versiot, joihin on asennettu magneettitoimilaitteet: - IP65-koteloitu tai - sertifioitu käytettäväksi räjähdysvaarallisissa ympäristöissä ATEX 94/9/EY -direktiivin mukaisesti - NAMUR-liitäntä suoraan asennukseen yksitoimiseen (3/2 NC -toiminto) tai kaksitoimiseen (5/2-toiminto) painetoimilaitteeseen. Venttiilin toiminta voidaan muuttaa 3/2 NC -toiminnosta 5/2-toimintoon asentamalla mukana toimitettu 3/2 NC- tai 5/2-liitäntälevy venttiilin pohjaan (kuvat 13a, 13b, kohta 1a ja 1b). 551, 1/4”, maks. syvyys 11,5 mm. (Älä yhdistä paineen syöttöä poistoaukko 3:een. ”Ympäristösuojattua” rakennetta ei ole sovitettu EI-toimintoon. Kysy meiltä erikoisversioissa käytettävissä olevista toiminnoista). - Liitä tarvittavien toimintojen putket näiden asiakirjojen ja tuotteen aukkomerkintöjen mukaisesti. - Varmista, ettei mitään vierasta ainesta pääse mukaan kiertoon, jottei venttiilin toiminta esty. Käytä mahdollisimman vähän eristysteippiä tai -aineita. - Nämä venttiilit on suunniteltu käytettäviksi puhtaan ja kuivan • Versiot, joissa on magneettitoimilaitteet ja ASCO-kiinilman tai reagoimattomien kaasujen kanssa. Suositeltava nitysalusta vähimmäissuodatus on 50 mikrometriä. Käytettävän väli- tai IP65-kotelointi vakiona tai jotka on tarkoitettu käytetaineen kastepisteen on oltava vähintään - 10 °C (18 °F) täväksi räjähdysvaarallisissa ympäristöissä standardien alle pienimmän mahdollisen lämpötilan, johon väliaine voi II 3D IP65/IP67 tai ATEX Ex d, m, em, Ex ia mukaisesti joutua. Käytettäessä voideltua ilmaa voiteluaineen on oltava (Sarja 551: II 1G/2D Ex ia IIC IP65/IP67 tai sarja 553: II yhteensopiva käytettyjen elastomeerien kanssa. ANSI/ISA 2G/D Ex ia IIC IP65/IP67). S7.3 (1975) -standardin vaatimukset täyttävä paineilma ylittää näiden venttiilien vaatimukset, ja se on siis hyväksyttävä • Versiot, joissa on ohjauslaitteet ja CNOMO E06.05.80 väliaine näihin venttiileihin. (koko 30)- tai CNOMO E06.36.120N (koko 15) -kiinnitysKaikki venttiilien poistoaukot ja ohjauslaitteet on alusta ! suojattavaruostumattomasta teräksestä valmistetuil- tai IP65-kotelointi vakiona tai joissa ohjauslaitteet asennela poistosuojuksilla. Kiinnitä poistoaukon suojat taan venttiilin käyttämiseksi räjähdysvaarallisissa ympärisaukkoon 3 (3/2 NC) tai aukkoihin 3-5 (5/2). Ulkokäytössä töissä ATEX Ex d- tai Ex ia -direktiivin mukaisesti. tai varastoitaessa pitkiksi ajoiksi ja/tai joutuessaan altAlueluokitus (ATEX 1999/927EY) määritetään ensisijaisesti tiiksi ankarille olosuhteille (pöly, nesteet jne.), on käytetventtiilin rungossa olevan tyyppikilven merkinnällä kuvat tävä poistoaukon suojia. 10 ja 20 (kohta E1 tai E2). ATEX 94/9/EY -direktiivin mukaiVenttiilin luotettavuutta ei voida taata, jos käytetään muuta nen turvakoodi: II 1 GD c T6 T85 °C Ta -40 °C...+65 °C kuin toimitettua poistoaukon suojaa. EY-tyyppitarkastustodistus nro: INERIS 03 ATEX 0219 X. - Hyväksyttävä käyttölämpötila-alue: -40 °C...+80 °C (sarja 551); Kun tämä tuote asennetaan ohjauslaitteeseen ATEX 94/9/ EY -direktiivin mukaisesti, epäedullisin luokka ja lämpötila, -40 °C...+60 °C (sarja 553). suurin käyttöpaine on otettava huomioon. Yhteensopivuus - Suurin käyttöpaine: - 2-10 baaria terveys- ja turvavaatimusten kanssa on varmistettu noudattamalla EY-standardeja EN 13463-1 ja EN 13463-5. Ohjaus- 2-8 bar baaria (ISSC/PISC/PISCIS/CFSCIS/CFSDIS/CFVTIS) laitteiden asennuspaikkoja kuvissa 4/5/14/15/21/22/23/24 ja ilmoitettuja kiristysmomentteja tulee noudattaa. KUVAUS ATEX 94/9/EY -standardin mukaiset versiot: Katso kohta ATEX 94/9/EY -direktiivin mukaisten magneettitoimilaitTurvalliset käyttöolosuhteet. teiden ja ohjauslaitteiden mukana toimitettuja asennusIlmakehästä eristetyt versiot: Venttiilin sisäiset osat on eris- ohjeita on ehdottomasti noudatettava. tetty ilmakehästä suojaksi syövyttävältä ympäristöltä. Kaikki ASENTAMINEN karaventtiilin poistoaukot voidaan putkittaa, jotta ne suojaavat ! ATEX 94/9/EY -standardin mukaiset versiot: Tarkista, ympäristöä paremmin. Putkitusta suositellaan etenkin herkillä alueilla kuten puhdastiloissa ja lääke- ja elintarviketeollisuu- että kaikki metalliset tai johtavat osat on aina kytketty toisiinsa dessa. Karaventtiilin sisäosien suojaamiseksi poistoaukkoihin ja maahan.Venttiilin runko kytketään maahan kiinnitysruuvilla on asennettava putket tai liittimet, jos karaventtiiliä käytetään (kohta F). ulkotiloissa tai ankarissa olosuhteissa (jotka sisältävät esim. Venttiilit voidaan asentaa mihin asentoon tahansa. pölyä tai nestettä). Kierreaukkoversiot 1/4 (kuva 3a), 1/2 (kuva 3b): TURVALLISET KÄYTTÖOLOSUHTEET Asenna venttiili kahdella ruuvilla (kohta 1) (eivät sisälly ATEX 94/9/EC -standardin mukaiset versiot: Venttiili pitää toimitukseen). liittää maahan (katso osiota "Asentaminen"). Väliaineen maksimilämpötila ei saa ylittää ympäristön läm- NAMUR-liitäntäversiot (kuvat 13a, 13b): pötilaa. Ennen kuin asennat karaventtiilin ohjauslaitteelle, aseta se Karaventtiiliä on säilytettävä alkuperäisessä pakkauksessaan, oikeaan toimintoon: jos sitä ei käytetä. Liitäntäaukkojen ja magneettitoimilaitteiden - Valitse liitäntä, joka vastaa oikeaa toimintoa: 3/2 NC tai 5/2 suojuksia ei saa poistaa. (kohta 1a tai 1b). Säilytysolosuhteet: Suojattava säältä. Säilytyslämpötila: - Varmista, että tiiviste on kunnolla paikallaan (kohta 7). -40...+70 °C. Suhteellinen kosteus: 95 % - Asenna liitäntä karaventtiilin alle kahdella mukana toimitetulla 18 3834901 ASENNUS- JA HUOLTO-OHJEET Sarjan 551 solenoidiventtiilit, joissa messinkirunko, tai sarjojen 551–553 venttiilit, joissa ruostumaton teräsrunko, ¼”:n tai ½”:n kierteet tai NAMUR-liitäntä ruuvilla (kohta 8). Varmista, että toimintoa kuvaava merkki on takana (avainhahto). - Aseta kaksi O-rengasta paikoilleen (kohta 9). - Aseta johtotappi ohjauslaitteeseen tarvittaessa: • 3/2 NC -toimintolevy: Ø 5 halk. aukko on kohdassa A1. • 5/2 -toimintolevy: Ø 5 halk. aukko on kohdassa A2. 3/2 NC 5/2 - 5/3 FI liittää (1/8 kierteellä) keräämään poistot. Asentaminen/säätäminen (kuva 3a) Versio 3/2 NC = asenna 1 paineenalennusventtiili aukkoon 3 Version 5/2 = asenna 2 paineenalennusventtiiliä aukkoihin 3 ja 5 Kiinnitä ruuvi (4) paineenalennusventtiilin reikään ja kierrä sitä, kunnes se pysähtyy. Kierrä sitä sitten ulospäin lisätäksesi poistovirtausta. (Aina korkeintaan kaksi kierrosta, maksimivirtaus yhdellä kierroksella). Kiristä lukkomutteri (4a) 13 mm:n ruuviavaimella. Tee likimääräiset säädöt ennen paineistusta ja hienosäätö paineistuksen jälkeen. PAINELIITÄNTÄ (kuvat 3a, 3b, 13a ja 13b) Versiosta riippuen (3/2 NC tai 5/2) voit käyttää yhtä tai kahta ruostumattomasta teräksestä valmistettua poistoaukon suojaa (katso kuva 2). • Paineohjauslaiteversion liittäminen: G 1/8 tai NPT 1/8 tai G 1/4 tai NPT 1/4. • Ohjauslaitteiden poistoaukkojen liittäminen Versiosta riippuen poistot voi kerätä yhteen. SÄHKÖLIITÄNTÄ • Versiot, joissa on magneettitoimiset päät ja ASCOliitäntä: Katso jokaisen magneettitoimisen pään mukana toimitetut erilliset asennusohjeet. IP65:n mukainen magneettitoimilaite (kuvat 3a, 3b, 13a ja 13b): Asenna kela putkeen (360° kierrettävä) ja sen jälkeen irrotettava ISO 4400/EN 175101-803A -liitin (kaapelin halk. 6–10 mm) 90°:n askelin kierrettävä (3 pinniä: 2 + maa). • Versiot, joissa CNOMO-kiinnitysalusta: Katso jokaisen ohjausventtiilin mukana toimitetut erilliset asennusohjeet. • Yleiset suositukset: Sähköliitännät saa tehdä vain valtuutetut henkilöt sovellettavien paikallisten standardien ja säännösten mukaisesti. Tärkeää: - Katkaise osien virransyöttö ennen asennuksen aloittamista. - Sen mukaan mikä on jännite, sähköliitännät on maadoitettava paikallisten standardien ja asetusten mukaisesti. Useimmissa venttiileissä on jatkuvaa toimintaa varten suunnitellut kelat. Henkilövahingon ehkäisemiseksi älä kosketa magneettitoimilaitetta, joka voi kuumentua normaaleissa käyttöolosuhteissa. Jos venttiiliin on helppo päästä käsiksi, asentajan on järjestettävä riittävä suojaus magneettitoimilaitteen tahattoman kosketuksen estämiseksi. • Käsitoiminen ohittaminen Riippuen versiosta, tuotteissa ei ole käsitoimista ohitusta tai niissä on impulssityyppinen käsitoiminen ohitus, joilla voit käyttää venttiiliä myös silloin, kun se ei ole jännitteellinen. Käsitoimisen ohituksen merkkinä on symboli ( )kuvissa 4, 5, 14, 15 ja 21–24 ja kohdassa 10 kuvissa 3a, 3b, 13a, 13b. Impulssityyppistä tai pitotyyppistä (painettava/käännettävä tyyppi) käsitoimista ohitusta, jonka merkkinä on symboli ( ), kuvissa 3a, 3b, 13a ja 13b, voidaan käyttää myös ilman sähköä. ! Ennen kuin otat laitteen käyttöön, varmista että käsitoiminen ohitus on sammutettu ja "0"-asennossa. Näin vältät henkilövahingot ja laitteiston vaurioitumisen. • Sovellus ulkoisen ohjauslaitteen syöttöön (kuvat 3a, 3b, 13a ja 13b, kohta 6) • Paineliitäntään liittyviä yleisiä suosituksia Liitä tarvittavien toimintojen putket näiden asiakirjojen ja tuotteen aukkomerkintöjen mukaisesti. Varmista, että järjestelmään ei pääse vierasta ainesta. Tue ja kohdista putket oikein, jotta venttiiliin ei kohdistu mekaanista rasitusta. Älä käytä venttiiliä kiristyksen aikana vipuna, vaan aseta vääntöavaimet mahdollisimman lähelle liitoskohtaa. Laitevaurion välttämiseksi ÄLÄ KIRISTÄ PUTKILIITOKSIA LIIKAA. HUOLTO ! Ennen venttiilin huoltamista tai käyttöönottoa katkaise virta, poista venttiilistä paine ja tuuleta venttiili henkilövahingon ja laitevaurion estämiseksi. ATEX-versiot: Noudata huollon aikana tarkoin kaikkia standardissa 99/92/EY suositeltuja ja siihen liittyvien standardien mukaisia toimenpiteitä. • Kierreaukkoversiot 1/4 (kuva 3a), 1/2 (kuva 3b): Karaventtiilin liittäminen: Liitä putket merkinnän mukaisesti: - 3/2 NC -toiminto: Painetulo aukossa 1 (1/4”:n tai 1/2”:n kierre). Painelähtö aukkoon 2. Poisto aukossa 3 (1/4”:n tai 1/2”:n kierre). - 5/2-toiminto: Painetulo aukkoon 1. Painelähtö aukkoihin 2 ja 4. Poistot kanavoidaan venttiilin kautta aukkoihin 3 ja 5. • Puhdistus Venttiilien huolto määräytyy käyttöolosuhteiden mukaan. Venttiilit on puhdistettava säännöllisin väliajoin. Huollon aikana on tarkistettava, ovatko osat kuluneet liikaa. Osat on puhdistettava, kun kierto silmin nähden hidastuu, vaikka ohjauspaine on oikea, tai venttiilistä kuuluu epätavallista ääntä tai siinä on vuoto. • NAMUR-liitäntäversiot (kuva 13a, 13b): Karaventtiilin liittäminen: Liitä putket merkinnän mukaisesti: - 3/2 NC -toiminto: Painetulo aukossa 1 (1/4”:n tai 1/2”:n kierre). Painelähtö aukkoon 2. Poisto aukkoon 3 (messinkirunko: 1/8, ruostumaton teräsrunko: 1/4”:n tai 1/2”:n kierre). Yksitoimisten versioiden paluuohjaimen jousikammioiden poisto johdetaan venttiilin läpi 1/8 tuuman 3-aukkoon. Suojaa 5-aukko (jos se ei ole käytössä) - älä tulppaa sitä. - 5/2-toiminto: Painetulo aukossa 1 (1/4”:n tai 1/2”:n kierre). Poistot kanavoidaan venttiilin kautta aukkoihin 3 ja 5 (messinkirunko: 1/8, ruostumaton teräsrunko: 1/4”:n tai 1/2”:n kierre). • Äänet Venttiilistä kuuluvat äänet määräytyvät käyttösovelluksen, virtaavan aineen ja käytetyn laitetyypin mukaan. Vain käyttäjä voi määrittää äänitason tarkasti, kun venttiili on asennettu järjestelmään. • Ennakoiva huolto - Tarkista venttiilin toiminta käyttämällä venttiiliä vähintään kerran kuukaudessa. - Jos huollon aikana ilmenee ongelmia tai sinulla on kysymyksiä, ota meihin tai valtuutettuun edustajaamme yhteyttä. • Vianmääritys - Väärä lähtöpaine: Tarkista, että venttiilin syöttöpuolen paine vastaa tyyppikilvessä ilmoitettua painetta. Tärkeää: minimiohjauspaine on 2 baaria. Tarkista henkilövahingon tai laitevaurion välttämiseksi, että venttiili toimii oikein, ennen kuin se otetaan taas käyttöön. • Paineenalennusventtiilin kytkentä (messinkirunko): Sarjan 551 karaventtiilit toimitetaan tilauksen mukaan pienikokoisilla 1/8”:n poiston alennusventtiileillä varustettuina tai ilman niitä, liite M (kuva 13a). Näillä säädettävillä, pienillä paineenalennusventtiileillä voidaan säätää laitteen käyttönopeutta. Ne voidaan myös • Varaosat Keloja on saatavana varaosina. Vaihda tarvittaessa koko venttiili. 19 3834901 INSTALLATIONS- OG VEDLIGEHOLDSANVISNINGER Solenoideventiler serie 551, messinghus, eller serierne 551-553, hus af rustfrit stål, ¼", ½" gevind eller NAMUR-grænseflade BESKRIVELSE AF GODKENDELSEN Versioner der falder under godkendelsen (Afbild. 1 og 11): Messinghus (serie 551) eller hus af rustfrit stål (serierne 551, 553), monostabile (fjederretur) eller bistabile, 3/2 NC-funktion (normalt lukket) eller 5/2, version isoleret fra den omgivende atmosfære. Versioner uden manuel overstyring eller med impuls-type manuel overstyring: - med gevindskårne porte 1/4 (551) eller 1/2 (553) - 551, med ¼” gevindtilslutning, maks. portdybde 11,5 mm. (Forbind ikke trykforsyningen til udløbsport 3. Den "miljøbeskyttede" konstruktion er ikke beregnet til en "distributionsfunktion" eller til brug i NO-funktion. Kontakt os med henblik på oplysning om, hvilke funktioner der er til rådighed på bestemte modeller). - med NAMUR interface til direkte montering på enkeltvirkende (funktion 3/2 NL) eller dobbeltvirkende (funktion 5/2) pneumatisk drev. Funktionen af ventilen er konvertibel fra 3/2 NL til 5/2 ved at montere den medfølgende 13/2 NL eller 5/2 interface plade i bunden af ventilen (fig. 13a, 13b, ref. 1a og 1b). 1/4”, maks. portdybde 11,5 mm. (Forbind ikke trykforsyningen til udløbsport 3. Den "miljøbeskyttede" konstruktion er ikke beregnet til NO-funktion. Kontakt os med henblik på oplysning om, hvilke funktioner der er til rådighed på bestemte modeller). - Forbind rørene til de krævede funktioner, som angivet i denne dokumentation og på port markeringerne på produktet. - For at forkomme at ventilens funktion bliver blokeret, skal det sikres, at der ikke kommer fremmedlegemer ind i kredsløbet. Begræns brugen af tætningsbånd eller tætningsmateriale til et minimum. - Disse ventiler er beregnet til brug med ren og tør luft eller inaktiv gas. Anbefalet minimumsfiltrering: 50 my. Dugpunktet af det medie der bliver brugt, skal ligge mindst -10°C (18°F) under den minimumstemperatur, som mediet kan blive udsat for. Når der bruges smurt luft, skal smøremidlet være forenelig med de benyttede elastomere. Instrumentluft i overensstemmende med ANSI/ISA standard S7.3 (1975) overgår de nødvendige krav, og er derfor et acceptabelt medie til disse ventiler. Alle ventilers og styreventilers udstødningsporte ! skal være beskyttet med udstødningsbeskyttere af rustfrit stål. Sæt udstødningsbeskytterne på port 3 (3/2 NC) eller port 3 - 5 (5/2). Ved anvendelse udendørs eller ved længere tids opbevaring, og/eller ved anvendelse i aggressive miljøer (støv, væsker etc.), skal der anvendes udløbsbeskyttere. Ventilens driftssikkerhed kan ikke garanteres, hvis der anvendes andre udløbsbeskyttere end de medfølgende. - Tilladte temperaturspektrum: -40° C til +80° C (serie 551); -40° C til +60° C (serie 553). - Maksimum arbejdstryk: - 2 til 10 bar - 2 til 8 bar (ISSC/PISC/PISCIS/CFSCIS/CFSDIS/CFVTIS) 3/2 NC 5/2 - 5/3 INSTALLATIONS- OG VEDLIGEHOLDSANVISNINGER DK Efter opbevaring ved lav temperatur, skal spoleventilen gradvist varmes op til driftstemperatur, før der bliver sat tryk på. Spoleventilen er beregnet til brug under de tekniske forhold, der er specificeret på fabriksskiltet. Forandringer på produktet må kun foretages efter samråd med producenten eller dennes repræsentanter. Disse magnetspoleventiler er konstrueret til brug med filtreret luft eller neutral gas. Overskrid ikke ventilens tilladte maksimumstryk = 8/10 bar (eller 8 bar med en Piezotronic pilotventil ifølge ATEX Ex ia). Overhold styredelens minimum trykværdi på 2bar. Installation og vedligehold af ventilen må kun udføres af kvalificeret personale. • Standard IP65-mærket luftdrifts versioner eller versioner til brug i eksplosive atmosfærer forårsaget af gasser, dampe, tåge eller støv i henhold til ATEX direktiv 94/9/EC. (Zoneklassifikationen for denne version er angivet på ATEX mærket, ref.E1). Sikkerhedskode, serie 551: II 1 GD c T6 T85° C Ta -40° C til +65° C Sikkerhedskode, serie 553: II 2 GD c T6 (T85°C), - T5 (T100°C). EF typetestcertifikat nr. (serie 551): INERIS 03 ATEX 0219 X Overensstemmelse med de væsentligste helbreds- og sikkerhedskrav er sikret ved overensstemmelse med de europæiske standarder EN 13463-1 og EN 13463-5. • Magnet-luftdrifts versioner med indbygget magnetstyreenhed: - IP65 forseglet eller - godkendt til brug i eksplosionsfarlige omgivelser i henhold til ATEX direktiv 94/9/EC. • Versioner med magnetstyring med ASCO montageplade, - IP65-mærket som standard, eller til brug i eksplosive atmosfærer II 3D IP65/IP67 eller ATEX Ex d, m, em, Ex ia (serie 551: II 1G/2D Ex ia IIC IP65/IP67 eller serie 553: II 2G/D Ex ia IIC IP65/IP67). • Versioner med piloter med CNOMO E06.05.80 (str. 30) eller CNOMO E06.36.120N (str. 15) montageplade, - IP 65-mærket som standard, eller montering af piloter til brug i eksplosive atmosfærer i henhold til ATEX Ex d eller Ex ia. Advarsel (CNOMO piloter): Zoneklassifikationen (ATEX 1999/927EC) er hovedsagelig defineret ved angivelserne på fabriksskiltet fig. 10 og 20 (ref. E1 eller E2) på ventilhuset. Sikkerhedskode i henhold til ATEX direktiv 94/9/ EF: II 1 GD c T6 T85° C Ta -40° C til +65° C EC typetest certifikat nr.: INERIS 03 ATEX 0219 X Ved monteringen af dette produkt på en styredel til ATEX 94/9/ECATEX 94/9/EC, skal der holdes regnskab med den mindst gunstige, maksimum arbejdstryk temperaturkategori. Overensstemmelse med de væsentligste helbreds- og sikkerhedskrav er sikret ved overensstemmelse med de europæiske standarder EN 13463-1 og EN 13463-5. BESKRIVELSE Styredelenes monteringsposition som den er vist i afbildninATEX 94/9/EC versionerne: Se "Særlige krav for sikker gerne 4/5/14/15/21/22/23/24 og det angivne stramningsmobrug". ment skal overholdes. Versioner isoleret fra atmosfæren: De indre dele af ven- For magnetstyreenheder og piloter til ATEX 94/9/EC, skal tilen er isolerede fra den omgivende atmosfære, for at give de instruktioner om brugen, der er givet i den specifikke beskyttelse i aggressive omgivelser. Alle udløbsåbninger kan installationsanvisning der fulgte med produktet, strengt tilsluttes til rørledninger, hvilket giver en bedre miljømæssig overholdes. beskyttelse, især anbefalet til sensitive områder som for eksempel rene rum, og installationer i den farmaceutiske MONTERING ! industri og i levnedsmiddelindustrien. Hvis spoleventilen ATEX 94/9/EC versionerne: Sørg for at alt metal bliver brugt udendørs eller i ubeskyttede omgivelser (støv, eller ledende dele altid er inbyrdes forbundet og forbundet til væsker o.s.v.), er det nødvendigt at tilslutte rør eller beslag til jordforbindelse. Ventilkassen er forbundet til jordforbindelse udløbsåbningerne, for at beskytte spoleventilens indre dele. med befæstelsesskruen (ref. F). Ventilerne kan monteres i alle positioner. SPECIELLE KRAV TIL SIKKER BRUG Gevindskårne porte version 1/4 (fig. 3a) 1/2 (fig. 3b): ATEX 94/9/EC versionerne: Ventilen skal jordforbindes (se monter ventilen med to skruer (ref. 1) (ikke leveret). "Montage"). Mediets maksimumstemperatur må ikke overstige omgivel- Versioner med NAMUR-grænseflade (fig. 13a, 13b): sestemperaturen. Før spoleventilen bliver monteret på aktivatoren, skal den Spoleventilen skal opbevares i sin originale indpakning, så indstilles til den krævede funktion: længe den ikke er i brug. Den beskyttende afdækning må ikke - Vælg den interface der passer til den krævede funktion: 3/2 fjernes fra forbindingsåbningerne og magnetstyreenhederne. NC eller 5/2 (ref. 1a eller 1b). Opbevaringsforhold: Beskyttet mod vejret; opbevaringstem- - Sørg for at pakningen er monteret rigtigt. peratur: -40 C til +70°C; relative fugtighedsgrad: 95 % - Monter interface, under spoleventilens med de 2 skruer der er leveret (ref.8). Sørg for at angivelsen af funktionen 20 3834901 Solenoideventiler serie 551, messinghus, eller serierne 551-553, hus af rustfrit stål, ¼", ½" gevind eller NAMUR-grænseflade er placeret på returløbssiden (polarisations udsparing). - Tilpas de to O-ringe (ref. 9). - Om nødvendigt, sæt styrepinden på operatøren: • På 3/2 NL pladen: er Ø 5 dia. hullet ved A1. • På 5/2 NL pladen: er Ø 5 dia. hullet ved A2. 3/2 NC 5/2 - 5/3 DK gevind) for at opsamle udstrømningen. Montage / justering (fig. 3a): Version 3/2 NC = 1 udløbsbegrænser til montering på port 3 Version 5/2 = 2 udløbsbegrænsere til montering på portene 3 og 5 Før skruen (4) på begrænseren ind i hullet og skru den ind indtil den stopper; drej den derefter ud for at øge udløbshastigheden (Aldrig mere end to omdrejninger, maks. stømningshastighed opnås efter en omdrejning). Stram låsemøtrikken (4a) med en 13 mm nøgle. Indstil omtrentligt før der bliver sat tryk på, og finjuster efter at trykket er sat på. PNEUMATISK FORBINDELSE (fig. 3a, 3b, 13a og 13b) Afhængigt af versionen (3/2 NL eller 5/2), skal der bruges en eller to rustfri stål udløbsbeskyttere (se fig. 2). • Montering af pneumatisk pilot version: G 1/8 eller NPT 1/8 eller G 1/4 eller NPT 1/4. • Montering af pilotens udløb Udstødningen kan opsamles som det passer bedst til den brugte version. • Manuel overstyring ELEKTRISK FORBINDELSE Afhængigt af versionen, er produktet leveret uden manuel • Versioner med magnetspolehoveder med ASCO interface: overstyring eller med impuls-type manuel overstyring til styring uden elektricitet. Den manuelle tilsidesættelse er Se de ekstra installationsinstruktioner der følger med hvert angivet med symbolet ( ) på fig. 4, 5, 14, 15, 21 til 24, og magnetspolehovede. ref. 10 på fig. 3a, 3b, 13a, 13b. IP65-klassificeret solenoideoperator (fig. 3a, 3b og 13a, Med den impulsstyrede eller faste (af typen tryk/drej) ma13b): Monter spolen på røret (så den kan drejes 360° rundt) nuelle tilsidesættelse, der er angivet af symbolet ( ) på og derefter det aftagelige ISO 4400/EN 175101-803A-stik fig. 3a, 3b, 13a og 13b, kan der foretages betjening uden (kabeldiameter 6-10 mm), der kan drejes 90º (3 ben: 2 + strøm. jord). • Version med CNOMO monteringsplade: ! Før ventilen bliver sat i gang, skal man sikre sig Se de ekstra installationsinstruktioner der følger med hver at den manuelle overstyring er drejer tilbage og koblet pilotventil. fra ved position "0" for at forebygge personskader eller • Generelle anbefalinger: skader på udstyr. Elektriske forbindelser skal udføres af kvalificeret personale • Tilpasning til ekstern pilotforsyning og i følge de gældende lokale standarder og forskrifter. (fig. 3a, 3b, 13a og 13b, ref. 6) Forsigtig: • Generelle anbefalinger i forbindelse med pneumatisk - Før der foretages noget arbejde, skal den elektriske strøm montering slås fra så komponenterne ikke står under spænding. Forbind rørene til de krævede funktioner, som angivet i denne - Afhængig af strømstyrken, skal elektriske komponenter dokumentation og på port markeringerne på produktet. jordforbindes i følge de lokale standarder og forskrifter. De fleste ventiler er udstyret med spoler der er konstruSørg for at ingen fremmedlegemer kommer ind i systemet. Understøt rørene korrekt og ret dem ind på linie, for at foreeret til kontinuerlig drift. For at forebygge personskader bygge mekanisk belastning på ventilen. Brug ikke ventilen må man ikke røre magnetenheden, som kan blive meget som håndgreb ved stramningen, men placer skruenøglen varm under normale driftsomstændigheder. Hvis der er let adgang til magnetventilen, skal installatøren sørge for så tæt på forbindingspunktet som muligt. For at undgå at skade udstyret, må rørforbindelserne IKKE OVERSPÆNbeskyttelse mod kontakt med magnetenheden ved et DES. uheld. VEDLIGEHOLD ! • Gevindskårne porte version 1/4 (fig. 3a) 1/2 (fig. 3b): Før der foretages noget vedligeholdsarbejde, eller Montering af spoleventilen: start af drift, skal den elektriske strøm slås fra, trykket Forbind rørene som vist på mærkesedlen: udløses og ventilen skal luftes for at forebygge person- 3/2 NL funktion: skader eller skader på apparatur. Trykindløb ved port 1 (1/4” eller 1/2” gevind). Trykudløb ATEX-versioner: Følg omhyggeligt alle procedurer, der ved port 2. anbefales af direktiv 99/92/EF og tilhørende standarder. Udstødning ved port 3 (1/4” eller 1/2” gevind). • Rengøring - 5/2 funktion: Vedligehold af ventilerne afhænger af driftsomstændigheder. Tryk indtag ved port 1. Tryk udløb ved portene 2 og 4. De skal gøres rent med regelmæssige mellemrum. Under vedligeholdsarbejdet skal komponenterne ses efter for Udstrømningen bliver ledt gennem ventilen til portene 3 og 5. unormal stærk slidtage. Komponenterne skal gøres rene når man mærker en nedsættelse i cyklusens hastighed, selvom styredelens tryk er korrekt, eller hvis der opstår en • Versioner med NAMUR interface (afbild. 13a, 13b): usædvanlig lyd eller lækage. Montering af spoleventilen: Forbind rørene som vist på mærket: • Lyd - 3/2 NL funktion: Lydstyrken afhænger af brugen, mediet og den type udstyr der er brugt. Den præcise iagttagelse af lydniveauet, kan Trykindløb ved port 1 (1/4” eller 1/2” gevind). Trykudløb kun blive gjort af den bruger, der har ventilen installeret i ved port 2. Udløb ved port 3 (messinghus: 1/8 ; hus af rustfrit stål: 1/4" sit system. eller 1/2" gevind). Udløb fra returoperatørens fjederkamre • Forebyggende vedligehold - Kør ventilen mindst en gang om måneden for at kontrollere i den enkeltvirkende version er ledt gennem ventilen til dens funktion. 1/8" Port 3. Det anbefales at beskytte port 5 (hvis den ikke er i brug) - den må ikke tætnes. - Dersom der opstår problemer under vedligeholdelsen, eller - 5/2 funktion: hvis du er i tvivl om noget, bedes du kontakte os eller en Trykindløb ved port 1 (1/4” eller 1/2” gevind). Trykudløb ved af vores autoriserede repræsentanter. portene 2 og 4. • Fejllokalisering Udstrømningen bliver ledt gennem ventilen til portene 3 og 5 - Forkert udstrømningstryk: Kontroller trykket på tilførselssiden af ventilen; det skal korrespondere med de værdier (messinghus: 1/8 ; hus af rustfrit stål: 1/4" eller 1/2" gevind). der er angivet på fabriksskiltet. Forsigtig: overhold minimum pilotens trykværdi på 2bar. • Tilkoblingen af udløbsbegrænsere (messing hus) For at undgå personskader eller skader på apparatur, Serie 551 gliderventilerne bliver leveret, som de er bestilt, skal der kontrolleres om ventilen fungerer korrekt, før den med eller uden miniature 1/8” udstødningsbegrænsere, sættes i drift igen. suffiks M (fig. 13a). • Reservedele Disse justerbare mini udløbsbegrænsere bruges til at justere Spoler er tilrådighed som reservedele. aktivatorens driftshastighed. De kan også monteres (1/8 Om nødvendigt, skift hele ventilen ud. 21 3834901 INSTRUÇÕES DE INSTALAÇÃO E MANUTENÇÃO Válvulas solenóides da série 551, corpo de latão, ou da série 551553, corpo de aço inoxidável, rosca de ¼", ½" ou interface NAMUR DESCRIÇÃO DA APROVAÇÃO Versões relacionadas com a aprovação (Fig. 1 - 11): Corpo de latão (série 551) ou de aço inoxidável (série 551, 553), monoestável (retorno da mola) ou biestável, função 3/2 NC (normalmente fechada) ou 5/2, versão isolada da atmosfera exterior. Versões sem sobreposição manual ou com sobreposição manual de tipo impulso: - com portas roscadas de 1/4 (551) ou 1/2 (553) - 551, com ligação de rosca de ¼", profundidade de porta máx. de 11,5 mm. (Não ligue o fornecimento de pressão à porta de escape 3. A construção “ambientalmente protegida” não está adaptada para uma função “de distribuição” ou utilização na função NO. Contacte-nos para saber as funções disponíveis em versões específicas.). - com interface NAMUR para montagem directa de accionadores pneumáticos de acção individual (função 3/2 NC) ou acção dupla (função 5/2). A função da válvula é convertível de 3/2 NC para 5/2 através da montagem da placa de interface 13/2 NC ou 5/2 fornecida na parte inferior da válvula (fig.13a, 13b, ref. 1a e 1b). 551, 1/4”, profundidade de porta máx. de 11,5 mm. (Não ligue o fornecimento de pressão à porta de escape 3. A construção “ambientalmente protegida” não está adaptada para a função NO. Contacte-nos para saber as funções disponíveis em versões específicas.). - Ligue os tubos para as funções requeridas de acordo com esta documentação e as marcas das portas no produto. - Certifique-se de que não entra nenhuma matéria estranha para evitar o bloqueio do funcionamento da válvula. Restrinja a utilização de fita vedante ou material vedante a um mínimo. - Estas válvulas destinam-se à utilização com ar seco e limpo ou gás inerte. Filtragem mínima recomendada: 50 mícrones. O ponto de condensação do fluído utilizado tem de estar a pelo menos -10°C (18°F) abaixo da temperatura mínima a que o fluído possa estar exposto. Quando utilizar ar lubrificado, o lubrificante tem de ser compatível com os elastómeros utilizados. O ar do instrumento em conformidade com as normas ANSI/ISA S7.3 (1975) excede os requisitos necessários e é, por isso, um fluído aceitável para estas válvulas. Tem de proteger todas as portas de saída das válvu! las e dos pilotos com protectores de saída de aço inoxidável. Ligue os protectores de escape à 3 (3/2 NC) ou às portas 3 - 5 (5/2). Quando utilizados no exterior ou guardados durante períodos de tempo mais longos, e/ou expostos a ambientes severos (poeiras, líquidos, etc.), tem de utilizar protectores de escape. A fiabilidade da válvula não pode ser garantida se utilizar um protector de escape diferente do fornecido. - Intervalo de temperatura permitido: De -40°C a +80°C (série 551); de -40°C a +60°C (série 553). - Pressão de trabalho máxima: - de 2 a 10 bar - de 2 a 8 bar (ISSC/PISC/PISCIS/CFSCIS/CFSDIS/CFVTIS) 3/2 NC 5/2 - 5/3 PT las de carretos têm de ficar gradualmente à temperatura de funcionamento antes da pressurização. As válvulas de carretos devem ser utilizadas de acordo com as especificações técnicas especificadas na placa de identificação. As alterações aos produtos só podem ser efectuadas após consulta ao fabricante ou ao seu representante. Estas válvulas de carretos de solenóide foram concebidas para operar com ar filtrado ou gás neutral. Não exceda pressão máxima permitida da válvula = 8/10 bar (ou uma válvula piloto Piezotronic de 8 bar para ATEX Ex ia). Cumpra a pressão piloto mínima de 2 bar. A instalação e a manutenção da válvula devem ser efectuadas apenas por pessoal qualificado. • Versões operadas a ar IP65 standard ou versões para utilização em atmosferas explosivas provocadas por gases, vapores, névoas ou poeiras de acordo com a Directiva ATEX 94/9/CE. (A classificação da zona desta versão é indicada na etiqueta ATEX, ref. E1). Código de segurança, série 551: II 1GD c T6 T85°C Ta De -40°C a +65°C Código de segurança, série 553:II 1GD cT6 (T85°C) -T5 (T100°C). Certificado de verificação de tipo CE nº (Série 551): INERIS 03 ATEX 0219 X A conformidade com os requisitos essenciais de saúde e segurança foi garantida de acordo com as normas europeias EN 13463-1 e EN 13463-5. • Versões operadas a ar equipadas com operadores de solenóide: - IP65 vedada ou - certificada para utilização em atmosferas explosivas de acordo com a Directiva ATEX 94/9/CE • Versões com operadores de solenóide e base de montagem ASCO, - IP65 classificada como standard, ou para utilização em atmosferas explosivas II 3D IP65/IP67 ou ATEX Ex d, m, em, Ex ia (Série 551: II 1G/2D Ex ia IIC IP65/IP67 ou série 553: II 2G/D Ex ia IIC IP65/IP67). • Versões com pilotos e base de montagem CNOMO E06.05.80 (tamanho 30) ou CNOMO E06.36.120N (tamanho 15), - IP65 classificada como standard, ou montagem de pilotos para utilização de acordo com a ATEX Ex d ou a Ex ia. A classificação da zona (ATEX 1999/927CE) é definida principalmente pelas indicações na chapa de identificação fig. 10 e 20 (ref. E1 ou E2) no corpo da válvula. Código de segurança de acordo com a directiva ATEX 94/9/CE: II 1 GD c T6 T85°C Ta De -40°C a +65°C Código de segurança de acordo com a Directiva ATEX 94/9/ CE: II 1 GD c T6 T85°C Ta de -40°C a +65°C. Certificado de verificação de tipo CE nº: INERIS 03 ATEX 0219 X. Quando montar este produto num piloto para ATEX 94/9/ EC, tenha em atenção a temperatura, pressão de trabalho máxima e a categoria menos favorável. A conformidade com os requisitos essenciais de saúde e segurança foi garantida de acordo com as normas europeias EN 13463-1 e EN 13463-5. Tem de cumprir a posição de montagem dos pilotos apresentada nas fig. 4/5/14/15/21/22/23/24 e os binários de aperto indicados. Para operadores de solenóide e pilotos ATEX 49/9/CE, as instruções de utilização fornecidas nas instruções de instalação específicas fornecidas com o produto têm de ser cumpridas. MONTAGEM ! Versões ATEX 94/9/CE: Certifique-se de que todas as peças condutoras ou metálicas estão sempre interligadas e ligadas a terra. O corpo da válvula fica ligado a terra com o parafuso de aperto (ref. F). As válvulas podem ser montadas em qualquer posição. Versões de porta roscada 1/4 (fig 3a), 1/2 (fig 3b): Monte a válvula com dois parafusos (rep. 1) (não fornecida). Versões com interface NAMUR (fig. 13a, 13b): Antes de montar a válvula de carretos no operador, tem de o definir para a função requerida: - Seleccione a interface correspondente à função requerida: 3/2 NC ou 5/2 (rep. 1a ou 1b). - Certifique-se de que o vedante está instalado correctamente (rep.7) - Monte a interface debaixo da válvula de carretos com os 2 parafusos fornecidos (rep.8). Certifique-se de que a DESCRIÇÃO Versões ATEX 94/9/CE: Consulte as "Condições especiais para utilização segura". Versões isoladas da atmosfera: As partes internas da válvula estão isoladas da atmosfera exterior para fornecer protecção em ambientes agressivos. Todas as portas de saída da válvula de carretos são ligáveis, fornecendo melhor protecção ambiente, recomendada especialmente para áreas sensíveis, como aplicações e salas limpas na indústria farmacêutica ou alimentar. É necessário ligar tubos ou acessórios às portas de saída para proteger as partes internas da válvula de carretos, se utilizada no exterior ou em ambientes severos (poeiras, líquidos, etc.). CONDIÇÕES ESPECIAIS PARA UTILIZAÇÃO SEGURA Versões ATEX 94/9/CE: A válvula tem de ser ligada à terra (ver "Montagem"). A temperatura máxima do fluído não deve exceder a temperatura ambiente. A válvula de carretos deve ser mantida na embalagem original enquanto não for utilizada. Não deve remover as tampas de protecção das portas de ligação e dos operadores de solenóide. Condições de armazenamento: protegida da exposição às condições meteorológicas; temperatura de armazenamento: de -40 C a +70°C; humidade relativa: 95 % Depois do armazenamento a baixa temperatura, as válvu- 22 3834901 INSTRUÇÕES DE INSTALAÇÃO E MANUTENÇÃO Válvulas solenóides da série 551, corpo de latão, ou da série 551553, corpo de aço inoxidável, rosca de ¼", ½" ou interface NAMUR indicação da função fica no lado de retorno (ranhura de polarização). - Instale os dois o-rings (rep. 9). - Se necessário, instale o perno guia no operador: • Na placa de funções da 3/2 NC: o orifício de 5 de diâmetro está na A1. • Na placa de funções da 5/2: o orifício de 5 de diâmetro está na A2. LIGAÇÃO PNEUMÁTICA (fig. 3a, 3b, 13a e 13b) Dependendo da versão (3/2 NC ou 5/2), pode utilizar um dos protectores de saída de aço inoxidável (ver fig. 2). • Ligação da versão de piloto pneumático: G 1/8 ou NPT 1/8 ou G 1/4 ou NPT 1/4. • Ligação de escapes do piloto Os escapes podem ser reunidos de acordo com a versão utilizada. • Sobreposição manual Dependendo da versão, os produtos são fornecidos sem sobreposição manual ou com sobreposição manual de tipo impulso para funcionamento sem corrente. A sobreposição manual é indicada com o símbolo ( ) nas fig. 4, 5, 14, 15, 21 a 24, e ref. 10 nas fig. 3a, 3b, 13a, 13b. A sobreposição manual (empurrar/rodar) mantida ou de impulso indicada pelo símbolo ( ) nas fig. 3a, 3b, 13a e 13b permite um funcionamento sem potência. 3/2 NC 5/2 - 5/3 PT Montagem / Ajuste (fig. 3a): Versão 3/2 NC = 1 redutor de escape para instalar na porta 3 Versão 5/2 = 2 redutores de escape para instalar nas portas 3e5 Encaixe o parafuso (4) do redutor no orifício e aparafuse-o até parar; rode-o para aumentar o fluxo de escape (nunca mais de duas voltas, fluxo máximo obtido numa volta). Aperte a porca de fixação (4a) com uma chave de porcas de 13 mm. Efectue um ajuste preliminar antes da pressurização e um ajuste fino depois da pressurização. LIGAÇÃO ELÉCTRICA • Versões com cabeças solenóides com interface ASCO: Consulte as instruções de instalação adicionais fornecidas com todas as cabeças solenóides. Operador de solenóide IP65 (fig. 3a, 3b e 13a, 13b): Monte a bobina no tubo (rotação de 360°) e, em seguida, o conector ISO 4400/EN 175101-803A amovível (diâmetro do cabo 6-10 mm) com rotação de 90° (3 pinos: 2 + terra). • Versão com base de montagem CNOMO: Consulte as instruções de instalação adicionais fornecidas com todas as válvulas piloto. • Recomendações gerais: As ligações eléctricas têm de ser efectuadas por pessoal qualificado e de acordo com os regulamentos e as normais locais aplicáveis. Precaução: - Antes de efectuar qualquer intervenção, desligue a corrente eléctrica para desactivar os componentes. - Dependendo da voltagem, os componentes eléctricos têm de ser ligados à terra de acordo com os regulamentos e as normas locais. A maior parte das válvulas está equipada com bobinas concebidas para trabalho contínuo. Para evitar lesões corporais, não toque no operador de solenóide que pode ficar quente em condições de funcionamento normais. Se a válvula tiver acesso fácil, o instalador deve utilizar equipamento de protecção para evitar qualquer contacto acidental com o operador de solenóide. ! Antes de a colocar em funcionamento, certifique-se de que a substituição manual volta à posição de desengrenagem "0" para evitar o risco de danos físicos ou materiais. • Adaptação ao fornecimento do piloto externo (fig.3a, 3b, 13a e 13b, ref.6) • Recomendações gerais para ligação pneumática Ligue os tubos para as funções requeridas de acordo com esta documentação e as marcas das portas no produto. Certifique-se de que não entra nenhuma matéria estranha no sistema. Apoie e alinhe correctamente os tubos para impedir o esforço mecânico da válvula. Quando apertar, não utilize a válvula como uma alavanca; coloque as chaves de bocas junto ao ponto de ligação. Para evitar danos no equipamento, NÃO APERTE EXCESSIVAMENTE as ligações do tubo. • Versões de porta roscada 1/4 (fig 3a), 1/2 (fig 3b): Ligação da válvula de carretos: Ligue os tubos como indicado na etiqueta: - Função 3/2 NC: Entrada de pressão na porta 1 (Rosca de 1/4” ou ½”). Saída de pressão na porta 2. Escape na porta 3 (Rosca de 1/4” ou ½”). - Função 5/2: Entrada de pressão na porta 1. Saída de pressão nas portas 2 e 4. Os escapes são canalizados através da válvula para as portas 3 e 5. • Versão com interface NAMUR (fig 13a, 13b): Ligação da válvula de carretos Ligue os tubos como indicado na etiqueta: - Função 3/2 NC: Entrada de pressão na porta 1 (Rosca de 1/4” ou ½”). Saída de pressão na porta 2. Escape na porta 3 (corpo de latão: 1/8 ; corpo de aço inoxidável: rosca de 1/4" ou 1/2"). Escape a partir das câmaras da mola de retorno do operador na versão de acção individual através da válvula para a porta 3 de 1/8". Recomendamos que proteja a porta 5 (se não utilizada) - não a pare. - Função 5/2: Entrada de pressão na porta 1 (Rosca de 1/4” ou ½”). Saída de pressão nas portas 2 e 4. Os escapes são canalizados através da válvula para as portas 3 e 5 (corpo de latão: 1/8 ; corpo de aço inoxidável: rosca de 1/4" ou 1/2"). • Ligação dos redutores de escape (corpo de latão): As válvulas de carretos da série 551 são fornecidas como encomendadas com ou sem redutores de escape de 1/8” miniaturas, sufixo M (fig. 13a). Estes redutores de escape ajustáveis são utilizados para ajustar a velocidade de funcionamento do accionador. Podem também ser ligados (rosca de 1/8) para recolher os escapes. MANUTENÇÃO ! Antes de efectuar qualquer trabalho de manutenção ou operação, desligue a corrente eléctrica, despressurize e descarregue a válvula para evitar lesões corporais ou danos no equipamento. Versões ATEX: Cumpra todos os procedimentos recomendados pela Directiva 99/92/CE e normas associadas. • Limpeza A manutenção das válvulas depende das condições de funcionamento. Têm de ser limpas em intervalos regulares. Deve verificar se os componentes têm um desgaste excessivo durante a assistência. Tem de limpar os componentes quando uma desaceleração do ciclo apesar da pressão do piloto estar correcta ou se detectar uma fuga ou ruído pouco usual. • Emissão de som A emissão de som depende da aplicação, material e tipo de equipamento utilizado. A determinação exacta do nível de som só pode ser efectuada pelo utilizador com a válvula instalada no sistema. • Manutenção preventiva - Opere a válvula pelo menos uma vez por mês para verificar o funcionamento. - Se detectar algum problema durante a manutenção ou em caso de dúvida, contacte-nos ou um dos representantes autorizados. • Resolução de problemas - Pressão de saída incorrecta: Verifique a pressão no lado de fornecimento da válvula; tem de corresponder aos valores indicados na placa de identificação. Precaução: cumpra valor mínimo de pressão do piloto de 2 bar. Para evitar lesões corporais ou danos no equipamento, verifique se a válvula funciona correctamente antes de a voltar a colocar em funcionamento. • Peças sobresselentes As bobinas estão disponíveis como peças sobresselentes. Se necessário, substitua a válvula inteira. 23 3834901 ΟΔΗΓΙΕΣ ΕΓΚΑΤΑΣΤΑΣΗΣ ΚΑΙ ΣΥΝΤΗΡΗΣΗΣ Çëåêôñïâáëâßäåò óåéñÜò 551, ìå ïñåé÷Üëêéíï êïñìü, Þ óåéñÜò 551-553, ìå êïñìü áðü áíïîåßäùôï ÷Üëõâá, óðåßñùìá 1/4“, 1/2" Þ äéáóýíäåóç NAMUR ΠΕΡΙΓΡΑΦΗ ΤΗΣ ΕΓΚΡΙΣΗΣ Εκδόσεις που αφορά η έγκριση (Εικ. 1 και 11): Ïñåé÷Üëêéíïò êïñìüò (óåéñÜ 551) Þ êïñìüò áíïîåßäùôïõ ÷Üëõâá (óåéñÜ 551, 553), ìïíïóôáèÞò (åðáíáöïñÜ åëáôçñßïõ) ή äéóôáèÞò, ëåéôïõñãßá 3/2 NC (κανονικά κλειστή) ή 5/2, Ýêäïóç áðïìïíùìÝíç áðü ôçí åîùôåñéêÞ áôìüóöáéñá. Εκδόσεις χωρίς μηχανική παράκαμψη ή με μηχανική παράκαμψη παλμικού τύπου: - με èõñßäåò ìå óðåßñùìá 1/4 (551) ή 1/2 (553) - 551, με σύνδεση σπειρώματος ¼’’, μέγιστο βάθος θύρας 11,5mm. (Μη συνδέετε την παροχή πίεσης στο στόμιο εξόδου 3. Η κατασκευή με “προστασία από συνθήκες περιβάλλοντος” δεν είναι προσαρμοσμένη για “διανεμητική” λειτουργία, ή χρήση σε λειτουργία NO. Επικοινωνήστε μαζί μας για τις διαθέσιμες λειτουργίες σε επιμέρους εκδόσεις). - με σύνδεση NAMUR για άμεση τοποθέτηση σε πνευματικό μηχανισμό απλής ενέργειας (λειτουργία 3/2 NC) ή διπλής ενεργείας (λειτουργία 5/2). Η λειτουργία της βαλβίδας είναι εναλλασσόμενη από 13/2 NC σε 5/2 με την τοποθέτηση της πλάκας σύνδεσης 3/2 NC ή 5/2 που διατίθεται, στη βάση της βαλβίδας (åéê.13a, 13b, âë. 1a και 1b). 1/4”, μέγιστο βάθος θύρας 11,5mm (Μη συνδέετε την παροχή πίεσης στο στόμιο εξόδου 3. Η κατασκευή με “προστασία από συνθήκες περιβάλλοντος” δεν είναι προσαρμοσμένη για λειτουργία NO. Επικοινωνήστε μαζί μας για τις διαθέσιμες λειτουργίες σε επιμέρους εκδόσεις). - Συνδέστε τους σωλήνες για τις απαιτούμενες λειτουργίες σύμφωνα με τα έγγραφα αυτά και τη σήμανση των στομίων στο προϊόν. - Φροντίστε να μην εισχωρήσουν ξένα σώματα στο κύκλωμα για να μη μπλοκάρει η λειτουργία της βαλβίδας. Περιορίστε τη χρήση στεγανωτικής ταινίας ή στεγανωτικής ουσίας στο ελάχιστο. - Οι βαλβίδες αυτές προορίζονται για χρήση με καθαρό και ξηρό αέρα ή αδρανές αέριο. Συνιστώμενη ελάχιστη διήθηση: 50 μικρά. ΤΟ σημείο δρόσου του ρευστού που χρησιμοποιείται πρέπει να είναι τουλάχιστον –10°C (18°F) κάτω από την ελάχιστη θερμοκρασία στην οποία μπορεί να εκτεθεί το ρευστό. Όταν χρησιμοποιείται λιπαινόμενος αέρας, το λιπαντικό πρέπει να είναι συμβατό με τα ελαστομερή που χρησιμοποιούνται. Ο εργαστηριακός αέρας κατά το πρότυπο ANSI/ISA S7.3 (1975) υπερκαλύπτει τις απαραίτητες προϋποθέσεις και αποτελεί, επομένως, ένα αποδεκτό ρευστό για τις βαλβίδες αυτές. Ïëåò ïé èýñåò åêôüíùóçò ôùí âáëâßäùí êáé ôùí ðéëüôùí ! ðñÝðåé íá ðñïóôáôåýïíôáé ìå ôá ðñïóôáôåõôéêÜ åêôïíùôþí áíïîåßäùôïõ ÷Üëõâá. Συνδέστε τα προστατευτικά για στόμιο εξόδου στη θύρα 3 (3/2 NC) ή θύρες 3 - 5 (5/2). Κατά την εξωτερική χρήση, ή κατά την αποθήκευση για μεγάλο χρονικό διάστημα και/ή κατά την έκθεση σε διαβρωτικά περιβάλλοντα (σκόνες, υγρά κλπ.), πρέπει να χρησιμοποιούνται προστατευτικά για στόμια εξόδου. Η αξιοπιστία της βαλβίδας δεν μπορεί να εγγυηθεί εάν χρησιμοποιείται προστατευτικό για στόμιο εξόδου διαφορετικό από το συγκεκριμένο που παρέχεται. - Επιτρεπόμενη θερμοκρασία: -40°C έως +80°C (σειρά 551), -40°C έως +60°C (σειρά 553). - Μέγιστη πίεση λειτουργίας: - 2 έως 10 bar - 2 έως 8 bar (ISSC/PISC/PISCIS/CFSCIS/CFSDIS/CFVTIS) 3/2 NC 5/2 - 5/3 GR Συνθήκες αποθήκευσης: απαιτείται προστασία από τα καιρικά φαινόμενα, θερμοκρασία αποθήκευσης: -40°C έως +70°C, σχετική υγρασία: 95 % Μετά την αποθήκευση σε χαμηλή θερμοκρασία, οι εμβολοβαλβίδες πρέπει να αποκτήσουν σταδιακά τη θερμοκρασία λειτουργίας πριν την εφαρμογή πίεσης σε αυτές. Οι εμβολοβαλβίδες προορίζονται για χρήση στα πλαίσια των τεχνικών χαρακτηριστικών που καθορίζονται στην πινακίδα τους. Αλλαγές στα προϊόντα επιτρέπονται μόνον αφού συμβουλευθείτε τον κατασκευαστή ή τον αντιπρόσωπό του. Αυτές οι ηλεκτρομαγνητικές εμβολοβαλβίδες έχουν σχεδιαστεί για λειτουργία με φιλτραρισμένο πεπιεσμένο αέρα ή ουδέτερο αέριο. Μην υπερβαίνετε τη μέγιστη επιτρεπτή πίεση στη βαλβίδα = 8/10 bar (ή 8 bar με πιεζοτρονική πιλοτική βαλβίδα κατά ATEX Ex ia). Τηρήστε την ελάχιστη τιμή πιλοτικής πίεσης 2 bar. Η εγκατάσταση και συντήρηση της βαλβίδας πρέπει να εκτελείται μόνο από εξειδικευμένο προσωπικό. • Εκδόσεις πεπιεσμένου αέρα, διαβάθμισης IP65, ή εκδόσεις για χρήση σε εκρηκτικό περιβάλλον που δημιουργούν αέρια, αναθυμιάσεις, νέφη ή σκόνες, σύμφωνα με την Οδηγία ATEX 94/9/ ΕΚ. (Η ζώνη ταξινόμησης αυτής της έκδοσης επισημαίνεται στην πινακίδα ATEX, σημ. E1). Κωδικός ασφαλείας, σειρά 551: II 1GD c T6 T85°C Ta -40°C Ýùò +65°C Κωδικός ασφαλείας, σειρά 553: II 2GD c T6 (T85°C) - T5 (T100°C) Πιστοποιητικό εξέτασης τύπου EC αρ. (Σειρά 551): INERIS 03 ATEX 0219 X Ç óõììüñöùóç ìå ôéò Ïõóéþäåéò áðáéôÞóåéò õãéåéíÞò êáé áóöÜëåéáò åîáóöáëßæåôáé äéáìÝóïõ ôçò óõììüñöùóçò ìå ôá ÅõñùðáúêÜ Ðñüôõðá EN 13463-1 και EN 13463-5. • Εκδόσεις που λειτουργούν με ηλεκτρομαγνήτη και πεπιεσμένο αέρα εξοπλισμένες με ηλεκτρομαγνητικό μηχανισμό: - στεγανοποιημένες κατά IP65 ή - πιστοποιημένες για χρήση σε εκρηκτικό περιβάλλον σύμφωνα με την Οδηγία ATEX 94/9/ΕΚ • Εκδόσεις με ηλεκτρομαγνητικό μηχανισμό και βάση στήριξης ASCO - διαβάθμισης IP65 ή για χρήση σε εκρηκτικό περιβάλλον II 3D IP65/IP67 ή κατά ATEX Ex d, m, em, Ex ia (Σειρά 551: II 1G/2D Ex ia IIC IP65/IP67 ή σειρά 553: II 2G/D Ex ia IIC IP65/IP67). • Εκδόσεις με πιλοτικό μηχανισμό και βάση στήριξης CNOMO E06.05.80 (μέγεθος 30) ή CNOMO E06.36.120N (μέγεθος 15), - διαβάθμισης IP 65, ή για χρήση σε εκρηκτικό περιβάλλον κατά ATEX Ex d ή Ex ia. Προσοχή (πιλοτικοί μηχανισμοί CNOMO): Η κατάταξη ζώνης (ATEX 1999/927EC) προσδιορίζεται κατά κύριο λόγο από τις ενδείξεις στην πινακίδα εικ. 10 και 20 (βλ. E1 ή E2) στον κορμό της βαλβίδας. Κωδικός ασφαλείας σύμφωνα με την Οδηγία ATEX 94/9/EΟΚ: II 1GD c T6 T85°C Ta -40°C Ýùò +65°C Πιστοποιητικό εξέτασης τύπου EC αρ.: INERIS 03ATEX0219 X. Κατά τη συναρμολόγηση αυτού του προϊόντος σε πιλοτικό μηχανισμό κατά ATEX 94/9/ΕΚ, πρέπει να λαμβάνεται η λιγότερο ευνοϊκή κατηγορία, mέγιστη πίεση λειτουργίας και θερμοκρασία. Ç óõììüñöùóç ìå ôéò Ïõóéþäåéò áðáéôÞóåéò õãéåéíÞò êáé áóöÜëåéáò åîáóöáëßæåôáé äéáìÝóïõ ôçò óõììüñöùóçò ìå ôá ÅõñùðáúêÜ Ðñüôõðá EN 13463-1 και EN 13463-5. ÐñÝðåé íá ôçñïýíôáé ç èÝóç ôïðïèÝôçóçò ôùí ðéëüôùí üðùò åéêïíßæåôáé óôá ó÷Þìáôá 4/5/14/15/21/22/23/24 και ïé áíáöåñüìåíåò ñïðÝò óýóöéîçò. Για τους ηλεκτρομαγνητικούς μηχανισμούς και τους πιλοτικούς μηχανισμούς κατά ATEX 49/9/ΕΚ, πρέπει να τηρούνται οι οδηγίες χρήσης καθώς και οι συγκεκριμένες οδηγίες εγκατάστασης που διατίθενται με το προϊόν. ΣΥΝΑΡΜΟΛΟΓΗΣΗ ! Εκδόσεις ATEX 94/9/ΕΚ: Φροντίστε όλα τα μεταλλικά ή αγώγιμα μέρη να είναι πάντα διασυνδεδεμένα μεταξύ τους και συνδεδεμένα με τη γείωση. Το σώμα της βαλβίδας συνδέεται με τη γείωση, μέσω της βίδας σύσφιξης (σημ. F). Οι βαλβίδες μπορούν να τοποθετηθούν σε οποιαδήποτε θέση. Åêäüóåéò èýñáò ìå óðåßñùìá 1/4 (åéê 3a), 1/2 (åéê 3b): Τοποθετήστε τη βαλβίδα με τις δύο βίδες (σημ. 1) (δεν διατίθενται). Åêäüóåéò με äéáóýíäåóç NAMUR (εικ. 13a, 13b): Πριν την τοποθέτηση της εμβολοβαλβίδας στον μηχανισμό, πρέπει να τη ρυθμίσετε στην απαιτούμενη λειτουργία. - Επιλέξτε τη βάση σύνδεσης που αντιστοιχεί στην απαιτούμενη λειτουργία: 3/2 NC ή 5/2 (σημ. 1a ή 1b). - Βεβαιωθείτε ότι η τσιμούχα έχει τοποθετηθεί σωστά (σημ. 7). - Τοποθετήστε τη βάση σύνδεσης κάτω από την εμβολοβαλβίδα ΠΕΡΙΓΡΑΦΗ Εκδόσεις ATEX 94/9/ΕΚ: Δείτε την ενότητα “Ειδικοί όροι ασφαλούς χρήσης”. Εκδόσεις απομονωμένες από την ατμόσφαιρα: Τα εσωτερικά εξαρτήματα της βαλβίδας είναι απομονωμένα από το εξωτερικό περιβάλλον με σκοπό την εξασφάλιση προστασίας σε επιθετικά περιβάλλοντα. Όλα τα στόμια εξόδου της εμβολοβαλβίδας διασωληνώνονται, παρέχοντας καλύτερη περιβαλλοντική προστασία, κάτι που συνιστάται ιδιαίτερα σε ευαίσθητους τομείς όπως οι “καθαροί χώροι” και εφαρμογές της φαρμακοβιομηχανίας ή της βιομηχανίας τροφίμων. Είναι αναγκαίο να συνδέσετε σωλήνες ή υδραυλικά εξαρτήματα στα στόμια εξόδου για να προστατεύσετε τα εσωτερικά εξαρτήματα της εμβολοβαλβίδας, όταν αυτή χρησιμοποιείται εξωτερικά ή σε σκληρό περιβάλλον (σκόνες, υγρά κλπ.). ΕΙΔΙΚΟΙ ΟΡΟΙ ΑΣΦΑΛΟΥΣ ΧΡΗΣΗΣ Εκδόσεις ATEX 94/9/ΕΚ: Η βαλβίδα πρέπει να γειωθεί (δείτε την ενότητα “Συναρμολόγηση”). Η μέγιστη θερμοκρασία του ρευστού δεν πρέπει να ξεπερνά τη θερμοκρασία περιβάλλοντος. Η εμβολοβαλβίδα πρέπει να διατηρείται στην αρχική της συσκευασία για όσο διάστημα δεν χρησιμοποιείται. Τα προστατευτικά καλύμματα δεν πρέπει να αφαιρούνται από τα στόμια σύνδεσης και τους ηλεκτρομαγνητικούς μηχανισμούς. 24 3834901 ΟΔΗΓΙΕΣ ΕΓΚΑΤΑΣΤΑΣΗΣ ΚΑΙ ΣΥΝΤΗΡΗΣΗΣ Çëåêôñïâáëâßäåò óåéñÜò 551, ìå ïñåé÷Üëêéíï êïñìü, Þ óåéñÜò 551-553, ìå êïñìü áðü áíïîåßäùôï ÷Üëõâá, óðåßñùìá 1/4“, 1/2" Þ äéáóýíäåóç NAMUR με τις 2 βίδες που διατίθενται (σημ. 8). Βεβαιωθείτε ότι η ένδειξη της λειτουργίας βρίσκεται στην πλευρά της επιστροφής (υποδοχή πόλωσης). - Τοποθετήστε τις δύο τσιμούχες (σημ. 9). - Αν χρειαστεί, τοποθετήστε τον φυτευτό πείρο στον μηχανισμό: • Στη βάση λειτουργίας 3/2 NC: η τρύπα διαμέτρου O 5 είναι στο A1. • Στη βάση λειτουργίας 5/2: η τρύπα διαμέτρου O 5 είναι στο A2.ÐÍÅÕÌÁÔÉÊÇ ÓÕÍÄÅÓÇ (εικ. 3a, 3b, 13a και 13b) Ανάλογα με ôçí Ýêäïóç (3/2 NC ή 5/2), ìðïñïýí íá ÷ñçóéìïðïéçèïýí Ýíá Þ äýï ðñïóôáôåõôéêÜ åêôüíùóçò áðü áíïîåßäùôï ÷Üëõâá (βλ. εικ. 2). • Σύνδεση της έκδοσης με πνευματικό πιλοτικό μηχανισμό: G 1/8 ή NPT 1/8 ή G 1/4 ή NPT 1/4. • Σύνδεση εξαγωγών πιλοτικού μηχανισμού Οι εξαγωγές μπορούν να συλλέγονται σε συλλέκτη, ανάλογα με την έκδοση που χρησιμοποιείται. • Μηχανική παράκαμψη Ανάλογα με την έκδοση, τα προϊόντα διατίθενται χωρίς μηχανική παράκαμψη ή με μηχανική παράκαμψη παλμικού τύπου για λειτουργία χωρίς ρεύμα. Ç ÷åéñïêßíçôç ðáñÜêáìøç õðïäåéêíýåôáé ìå ôï óýìâïëï ( ) óôçí åéκ. 4, 5, 14, 15, 21 Ýùò 24, και âë. 10 óôçí åéκ. 3a, 3b, 13a, 13b. Ç ÷åéñïêßíçôç ðáñÜêáìøç êñïõóôéêïý ôýðïõ Þ äéáôÞñçóçò (ôýðù ðßåóçò êáé ðåñéóôñïöÞò) ðïõ õðïäçëþíåôáé ìå ôï óýìâïëï ( ) óôçí åéκ. 3a, 3b, 13a και 13b επιτρέπει ôç ëåéôïõñãßá ÷ùñßò éó÷ý. Πριν από τη θέση σε λειτουργία, φροντίστε να γυρίσετε ! τον μηχανισμό μηχανικής παράκαμψης σε θέση απεμπλοκής “Ο” για να αποτραπεί ο κίνδυνος τραυματισμού ή ζημιάς του εξοπλισμού. • Προσαρμογή σε εξωτερική πιλοτική παροχή (εικ.3a, 3b, 13a και 13b, βλ. 6) • Γενικές συστάσεις για την πνευματική σύνδεση Συνδέστε τους σωλήνες για τις απαιτούμενες λειτουργίες σύμφωνα με τα έγγραφα αυτά και τη σήμανση των στομίων στο προϊόν. Φροντίστε να μην εισχωρήσουν ξένα σώματα στο σύστημα. Στηρίξτε κατάλληλα και ευθυγραμμίστε τους σωλήνες για να μην αναπτύσσονται μηχανικές τάσεις στη βαλβίδα. Κατά τη σύσφιξη, μη χρησιμοποιείτε τη βαλβίδα ως μοχλό, τοποθετήστε τα εργαλεία όσο το δυνατόν πιο κοντά στο σημείο σύνδεσης. Για να αποφύγετε ζημιά στον εξοπλισμό, ΜΗ ΣΦΙΓΓΕΤΕ ΥΠΕΡΒΟΛΙΚΑ τις συνδέσεις των σωλήνων. • Åêäüóåéò èýñáò ìå óðåßñùìá 1/4 (åéê 3a), 1/2 (åéê 3b): Σύνδεση της εμβολοβαλβίδας: Συνδέστε τους σωλήνες όπως φαίνεται στην πινακίδα: - Λειτουργία 3/2 NC: Είσοδος πίεσης στην θύρα 1 (με σπείρωμα 1/4” ή 1/2”). ¸îïäïò ðßåóçò óôç èýñá 2. Åêôüíùóç óôç èýñá 3 (óðåßñùìá 1/4” ή 1/2”). - Λειτουργία 5/2: Είσοδος πίεσης στο στόμιο 1. Έξοδος πίεσης στα στόμια 2 και 4. Οι εξαγωγές περνούν μέσα από τη βαλβίδα και καταλήγουν στα στόμια 3 και 5. • Έκδοση με σύνδεση NAMUR (εικ. 13a): Σύνδεση της εμβολοβαλβίδας: Συνδέστε τους σωλήνες όπως φαίνεται στην πινακίδα: - Λειτουργία 3/2 NC: Είσοδος πίεσης στην θύρα 1 (με σπείρωμα 1/4” ή 1/2”). ¸îïäïò ðßåóçò óôç èýñá 2. Εξαγωγή στο στόμιο 3 (ïñåé÷Üëêéíïò êïñìüò: 1/8, êïñìüò áíïîåßäùôïõ ÷Üëõâá: óðåßñùìá 1/4" Þ 1/2"). Η εξαγωγή από τους θαλάμους του ελατηρίου επιστροφής του μηχανισμού απλής ενεργείας διοχετεύεται μέσω της βαλβίδας στο στόμιο 3 1/8". Προτείνεται προστασία του στομίου 5 (αν δεν χρησιμοποιείται) - μην το φράζετε. - Λειτουργία 5/2: Åßóïäïò ðßåóçò óôçí èýñá 1 (ìå óðåßñùìá 1/4” ή 1/2”). Έξοδος πίεσης στα στόμια 2 και 4. εξαγωγές περνούν μέσα από τη βαλβίδα και καταλήγουν στα στόμια 3 και 5 (ïñåé÷Üëêéíïò êïñìüò: 1/8, êïñìüò áíïîåßäùôïõ ÷Üëõâá: óðåßñùìá 1/4" Þ 1/2"). • lΣύνδεση των μειωτήρων εξαγωγής (ορειχάλκινο σώμα): Ïé åìâïëïåéäåßò âáëâßäåò óåéñÜò 551 ðáñÝ÷ïíôáé áíÜëïãá ìå ôçí ðáñáããåëßá ìå Þ ÷ùñßò óõóôïëÝò åîáãùãÞò ìéíéáôïýñáò 1/8”, ðáñÝêôáìá M (εικ. 13a). Αυτοί οι ρυθμιζόμενοι μικρομειωτήρες εξαγωγής χρησιμοποιούνται για τη ρύθμιση της ταχύτητας λειτουργίας του μηχανισμού. 3/2 NC 5/2 - 5/3 GR Μπορούν επίσης να συνδεθούν (σπείρωμα 1/8") για τη συλλογή των εξαγωγών. Óõíáñìïëüãçóç / Ñýèìéóç (εικ. 3a): Έκδοση 3/2 NC = 1 μειωτήρας εξαγωγής στο στόμιο 3 Έκδοση 5/2 = 2 μειωτήρες εξαγωγής στα στόμια 3 και 5 Συνδέστε τη βίδα (4) στο μειωτήρα μέσα από την οπή και βιδώστε τη μέχρι το τέρμα, στη συνέχεια ξεβιδώστε την για να αυξηθεί η ροή της εξαγωγής (ποτέ περισσότερο από δύο στροφές, η μέγιστη ροή επιτυγχάνεται στη μία στροφή). Σφίξτε το ασφαλιστικό παξιμάδι (4a) με κλειδί 13 mm. Κάντε χονδρική ρύθμιση πριν από τη συμπίεση και λεπτή ρύθμιση μετά τη συμπίεση. ΗΛΕΚΤΡΙΚΗ ΣΥΝΔΕΣΗ • Έκδοση με ηλεκτρομαγνητικές κεφαλές και σύνδεση ASCO: Δείτε τις πρόσθετες οδηγίες εγκατάστασης που διατίθενται με κάθε ηλεκτρομαγνητική κεφαλή. Χειριστής ηλεκτροβαλβίδων κατηγορίας IP65 (εικ. 3a, 3b και 13a, 13b): Τοποθετήστε το πηνίο στον σωληνίσκο (δυνατότητα περιστροφής 360°) και στη συνέχεια τον αφαιρούμενο συνδετήρα ISO 4400/EN 175101-803A (διάμ. καλωδίου 6-10 mm) που περιστρέφεται κατά 90° (3 ακίδες: 2 + ãåßùóç). • Έκδοση με βάση τοποθέτησης CNOMO: Δείτε τις πρόσθετες οδηγίες εγκατάστασης που διατίθενται με κάθε πιλοτική βαλβίδα. • Γενικές συστάσεις: Οι ηλεκτρικές συνδέσεις πρέπει να γίνουν από εξειδικευμένο προσωπικό και σύμφωνα με τις κατά τόπους ισχύουσες διατάξεις και κανονισμούς. Προσοχή: - Πριν από οποιαδήποτε παρέμβαση, κλείστε την παροχή ρεύματος για να απενεργοποιήσετε τα εξαρτήματα. - Ανάλογα με την τάση, τα ηλεκτρικά εξαρτήματα πρέπει να γειώνονται σύμφωνα με τις κατά τόπους ισχύουσες διατάξεις και κανονισμούς. Οι περισσότερες βαλβίδες διαθέτουν πηνίο σχεδιασμένο για συνεχή λειτουργία. Για να αποτραπεί ο κίνδυνος τραυματισμού, μην αγγίζετε τον ηλεκτρομαγνητικό μηχανισμό, οποίος μπορεί να καίει πολύ σε κανονικές συνθήκες λειτουργίας. Αν η βαλβίδα έχει εύκολη πρόσβαση, ο εγκαταστάτης πρέπει να εξασφαλίσει προστασία που να μην επιτρέπει τυχαία επαφή με τον ηλεκτρομαγνητικό μηχανισμό. ΣΥΝΤΗΡΗΣΗ ! Πριν από κάθε εργασία συντήρησης ή τη θέση σε λειτουργία, διακόψτε την παροχή ρεύματος, αποσυμπιέστε και εξαερώστε τη βαλβίδα για να αποτραπεί κίνδυνος τραυματισμού ή ζημιάς του εξοπλισμού. Åêäüóåéò ATEX: ÔçñÞóôå áðáñÝêêëéôá üëåò ôéò äéáäéêáóßåò ðïõ óõíéóôÜ ç Ïäçãßá 99/92/EC êáé ôá óõíáöÞ ðñüôõðá. • Καθαρισμός Η συντήρηση των βαλβίδων εξαρτάται από τις συνθήκες λειτουργίας. Πρέπει να καθαρίζονται σε τακτά χρονικά διαστήματα. Κατά τη συντήρηση, πρέπει να γίνεται έλεγχος των εξαρτημάτων για υπερβολική φθορά. Τα εξαρτήματα πρέπει να καθαρίζονται αν παρατηρηθεί επιβράδυνση του κύκλου, ακόμα και αν η πιλοτική πίεση είναι σωστή, ή αν εντοπιστεί ασυνήθιστος θόρυβος ή διαρροή. • Εκπομπή θορύβου Η εκπομπή θορύβου εξαρτάται από την εφαρμογή, το μέσο και τον τύπο του εξοπλισμού που χρησιμοποιείται. Ο ΑΚΡΙΒΗΣ ΠΡΟΣΔΙΟΡΙΣΜΟΣ ΤΗΣ ΣΤΑΘΜΗΣ ΘΟΡΥΒΟΥ ΜΠΟΡΕΙ ΝΑ ΓΙΝΕΙ ΜΟΝΟ ΑΠΟ ΤΟΝ ΧΡΗΣΤΗ ΜΕ ΤΗ ΒΑΛΒΙΔΑ ΤΟΠΟΘΕΤΗΜΕΝΗ ΣΤΟ ΣΥΣΤΗΜΑ. • Προληπτική συντήρηση - Λειτουργήστε τη βαλβίδα τουλάχιστον μία φορά το μήνα για να ελέγξετε τη λειτουργία της. - Εάν åìöáíéóôïýí ðñïâëÞìáôá êáôÜ ôç óõíôÞñçóç Þ Ý÷åôå áìöéâïëßåò, ðáñáêáëïýìå επικοινωνήστε ìáæß ìáò Þ ìå êÜðïéï åîïõóéïäïôçìÝíï áíôéðñüóùðï. • Αντιμετώπιση προβλημάτων - Λανθασμένη πίεση εξόδου: Ελέγξτε την πίεση στην πλευρά εισόδου της βαλβίδας, πρέπει να ανταποκρίνεται στις τιμές που επισημαίνονται στην πινακίδα. Προσοχή: τηρήστε την ελάχιστη τιμή πιλοτικής πίεσης 2 bar. Για να αποφευχθεί τραυματισμός ή ζημιά στον εξοπλισμό, ελέγξτε αν η βαλβίδα λειτουργεί σωστά πριν την βάλετε πάλι σε λειτουργία. • Ανταλλακτικά Τα πηνία είναι διαθέσιμα ως ανταλλακτικά. Αν χρειαστεί, αντικαταστήστε ολόκληρη τη βαλβίδα. 25 3834901 Návod k instalaci a údržbě Elmg. ventily řady 551, mosazné těleso, nebo řady 551-553, těleso z nerezavějící oceli, 1/4“, 1/2" závit nebo uspořádání NAMUR POPIS SCHVÁLENÍ Verze zahrnuté do schválení (obr. 1 a 11): Mosazné těleso (řada 551) nebo těleso z nerezavějící oceli (řada 551, 553), monostabilní (vratná pružina) nebo bistabilní, 3/2 NC (rozpínací) funkce nebo 5/2, verze izolovaná od okolního prostředí. Verze s ručním ovládáním nebo bez něho. - s otvory Ľ“ (551) se závitem nebo ½“ (553) - 551, s Ľ” pozlaceným konektorem, Max. hloubka portu 11,5 mm. (Nepřipojujte tlakový zdroj k výstupnímu portu 3. Konstrukce „chránící prostředí“ není přizpůsobena pro funkci „distribuce“ nebo použití BEZ funkce. Kontaktujte nás pro funkce dostupné v určitých verzích). - s uspořádáním NAMUR pro přímou montáž na jednočinný (funkce 3/2 NC) nebo dvojčinný (funkce 5/2) pneumatický pohon. Funkci ventilu lze měnit z 3/2 NC na 5/2 namontováním dodané desky rozhraní 3/2 NC nebo 5/2 na spodní stranu ventilu (obr.13a, 13b, ref. 1a a 1b). 551, max. 1/4” hloubka portu = 11,5 mm. (Nepřipojujte tlakový zdroj k výstupnímu portu 3. Konstrukce „chránící prostředí“ není přizpůsobena pro použití BEZ funkce Kontaktujte 3/2 NC 5/2 CZ jovou teplotu. Cívkové ventily je možné používat v rámci technických charakteristik uvedených na typovém štítku. Změny vybavení jsou povoleny pouze po konzultaci s výrobcem nebo jeho zástupcem. Elmg. cívkové ventily jsou určeny pro použití s filtrovaným vzduchem nebo neutrálním plynem. nepřekračujte max. přípustný tlak ventilu 10 barů (nebo 8 barů s pilotním ventilem Piezotronic podle směrnice ATEX Ex ia). Upozornění: Sledujte minimální tlak pilota 2 bary. Instalaci a údržbu ventilu smí provádět pouze kvalifikované osoby. ● Standardní, vzduchem ovládané verze s krytím IP65 nebo verze pro použití ve výbušném prostředí vyvolaném plyny, výpary, mlhou nebo prachem podle Směrnice ATEX 94/9/EC. (Klasifikace zóny pro tuto verzi je stanovena na typovém štítku ATEX, ref. E1). Bezpečnostní kód, řada 551: II 1GD c T6 T85 °C Ta -40 °C až +65 °C Bezpečnostní kód, řada 553: II 2GD c T6 (T 85 °C) - T5 (T 100 °C) Číslo certifikátu typové zkoušky EC (Řada 551): INERIS 03 ATEX 0219 X Shoda se základními požadavky na ochranu zdraví a bezpečnost je zajištěna shodou s evropskými normami EN 13463-1 nás pro funkce dostupné v určitých verzích). Připojte potrubí pro požadované funkce podle této dokumen- a EN 13463-5. tace a označení otvorů na výrobku. - Zajistěte, aby se do obvodu nedostala žádná cizí látka, aby • Elmg. verze ovládané vzduchem osazené solenoidním nedošlo k zablokování funkce ventilu. Omezte na minimum pohonem: - krytí IP65 nebo certifikovány pro použití ve výbušném propoužití těsnicí pásky nebo těsnicí hmoty. - Ventily jsou určeny pro použití s čistým a suchým vzduchem středí podle Směrnice ATEX 94/9/EC. nebo inertním plynem. Doporučená minimální filtrace: 50 mikronů. Rosný bod kapaliny musí být alespoň -10 °C pod • Verze se solenoidním pohonem s montážní deskou minimální teplotou, které může být kapalina vystavena. Při ASCO, standardně s krytím IP65, nebo pro použití ve výbušpoužití mazacího vzduchu musí být mazivo kompatibilní s ném prostředí II 3D IP65/IP67 nebo ATEX EEx d, m, em, ia použitými elastomery. Přístrojový vzduch odpovídající normě (Řada 551: II 1G/2D Ex ia IIC IP65/IP67 nebo řada 553: II ANSI/ISA S7.3 (1975) převyšuje nezbytné požadavky a je 2G/D Ex ia IIC IP65/IP67). proto pro tyto ventily přijatelnou kapalinou. • Verze s piloty s montážní deskou CNOMO E06.05.80 Všechny výfukové otvory ventilů a pilotů musí být (velikost 30) nebo CNOMO E06.36.120N (velikost 15), ! chráněny chráničem z nerezavějící oceli. Připojte standardně s krytím IP 65, nebo s namontovanými piloty pro chrániče výfuku k portu 3 (3/2 NC) nebo portům 3 – 5 použití ve výbušném prostředí podle ATEX EEx d nebo Ex ia. (5/2) ventilů. Při použití venku, nebo při dlouhodobém Upozornění (piloty CNOMO): Klasifikace zóny (ATEX skladování, nebo při vystavení působení drsného pro- 1999/927EC) je definována zejména označením na typostředí (prachy, kapaliny a podobně) chrániče musí být vém štítku obr. 10 a 20 (ref. E1 nebo E2) na tělese ventilu. použity. Při použití jiného chrániče než toho, který byl Bezpečnostní kód podle Směrnice ATEX 94/9/EC: II 1GD dodán s výrobkem, nelze garantovat spolehlivost venti- c T6 T85 °C Ta -40 °C až +65 °C lu. Číslo certifikátu typové zkoušky EC: INERIS 03 ATEX 0219 X - Přípustný teplotní rozsah: -40 °C až +80 °C (řada 551); -40 °C až +60 °C (řada 553). Při sestavování výrobku s pilotem podle směrnice ATEX - Max. rozsah provozního tlaku: 94/9/EC použijte nejméně příznivou kategorii a teplo-2 až 10 barů tu. Shoda se základními požadavky na ochranu zdraví a -2 až 8 barů (ISSC/PISC/PISCIS/CFSCIS/CFSDIS/ bezpečnost je zajištěna shodou s evropskými normami EN CFVTIS) 13463-1 a EN 13463-5. Montážní pozice pilotů je uvedena na obrázcích 4/5/14/15/21/22/23/24. Je třeba dodržet vyznačené OBECNÝ POPIS utahovací momenty. Verze ATEX 94/9/EC: Viz „Speciální podmínky pro bezpeèné použíVerze ATEX 94/9/EC: Viz „Speciální podmínky pro U solenoidních pohonů a pilotů podle směrnice ATEX 49/9/ bezpečné používání“. EC je třeba přísně dodržovat pokyny k používání uvedené Verze izolované od okolního prostředí: Vnitřní části ventilu v konkrétním Návodu k instalaci dodaném s výrobkem. jsou izolovány od okolního prostředí, aby byla zajištěna ochrana v agresivních prostředích. Všechny výfukové otvory MONTÁŽ ! Verze ATEX 94/9/EC: Všechny kovové a vodivé části cívkového ventilu lze připojit k potrubí, což poskytuje lepší ochranu životního prostředí, a zvláště se to doporučuje v musí být vždy vzájemně propojeny a uzemněny. Těleso citlivých oblastech, např. v čistých provozech a aplikacích ventilu je uzemněno pomocí upevňovacího šroubu (ref. F). ve farmaceutickém nebo potravinářském průmyslu. K výfuko- Ventily lze namontovat v libovolné pozici. vým portům je třeba připojit potrubí nebo armaturu, aby byly chráněny vnitřní části cívkového ventilu, je-li použit venku, v Verze s otvory se závitem Ľ“ (obr. 3a), ½“ (obr. 3b): Namontujte ventil pomocí dvou šroubů (ref. 1) (nejsou soudrsném prostředí (prachy, kapaliny atd.). částí dodávky). SPECIÁLNÍ PODMÍNKY PRO BEZPEČNÉ POUŽÍVÁNÍ ATEX 94/9/EC: Ventil musí být uzemněn (viz „Montáž“). Verze s uspořádáním NAMUR (obr. 13a, 13b): Maximální teplota kapaliny nesmí převýšit okolní teplotu. Před namontováním cívkového ventilu na ovládací člen musí Cívkový ventil ponechte v originálním balení, dokud ho ne- být ventil nastaven na požadovanou funkci: budete používat. Nesnímejte ochranné kryty z připojovacích - Zvolte desku rozhraní odpovídající požadované funkci: 3/2 NC nebo 5/2(ref. 1a nebo 1b). otvorů a solenoidních pohonů. Podmínky pro skladování: chraňte před povětrnostními vlivy- - Zkontrolujte, zda je těsnění řádně usazeno (ref. 7). ;teplota skladování: -40 C až +70 °C ; relativní vlhkost: 95 % - Namontujte desku rozhraní pod cívkový ventil pomocí 2 Při skladování v nízkých teplotách musí být cívkové dodaných šroubů (ref. 8) a sledujte směr montáže. Zkonventily před zvýšením tlaku postupně zahřáty na poko- trolujte, zda je označení funkce umístěno na vratné straně 26 3834901 Installation and Maintenance Instructions Series 551 solenoid valves, brass body, or series 551-553, stainless steel body, 1/4“, 1/2" thread or NAMUR interface (polarizační otvor). - Nasaďte dva o-kroužky (ref. 9). - V případě potřeby umístěte polarizační pin na ovládací člen. Polarizační otvor o průměru 5 na desce rozhraní 3/2 je A1. Polarizační otvor o průměru 5 na desce rozhraní 5/2 je A2. • Připojení výfuků pilota Výfukové otvory lze vybrat podle použité verze. CZ Verze 3/2 NC = 1 výfuková redukce se namontuje na otvor 3 Verze 5/2 = 2 výfukové redukce se namontují na otvory 3 a 5 Vložte šroub (4) na redukci do otvoru a zašroubujte ho až na doraz. Potom jím otočte tak, abyste zvýšili průtok výfukových plynů (ne více než o dvě otáčky, max. průtok získáte po jedné otáčce). Dotáhněte pojistnou matici (4a) 13mm klíčem. Před zvýšením tlaku proveďte hrubé nastavení a po zvýšení tlaku jemné doladění. PŘIPOJENÍ VZDUCHU (obr. 3a, 3b, 13a a 13b) V závislosti na verzi (3/2 NC nebo 5/2) lze použít jeden nebo oba chrániče výstupu z nerezavějící oceli (viz obr. 2). • Připojení verze s pneumatickým pilotem: G 1/8 nebo NPT 1/8 nebo G 1/4 nebo NPT 1/4. 3/2 NC 5/2 ELEKTRICKÉ ZAPOJENÍ • Verze se solenoidním pohonem s rozhraním ASCO: Viz další pokyny k instalaci dodané s konkrétním solenoidním pohonem. Solenoidem ovládaný IP65 (obr. 3a, 3b a 13a, 13b): Namontujte cívku na trubičku (otočnou o 360°) a potom na snímatelný konektor ISO 4400/EN 175101-803A (průměr kabelu 6-10 mm) otočný o 90° (3 piny: 2 + zem). • Ruční ovládání V závislosti na verzi se výrobky dodávají s ručním ovládáním nebo bez něho pro provoz bez napájení. Ruční ovládání je označeno symbolem ( ) na obr. 4, 5, 14, 15, 21 až 24, • Verze s montážní dekou CNOMO: Viz další pokyny k a ref. 10 na obr. 3a, 3b, 13a, 13b. instalaci dodané s konkrétním pilotním ventilem. Pulsní typ nebo s ručním ovládáním (typ push/turn) označené symbolem ( ) na obr. 3a, 3b, 13a a 13b umožňují • Obecná doporučení: provoz bez napájení. Elektrické zapojení musí provést kvalifikovaná osoba podle platných místních norem a předpisů. ! Před uvedením do provozu se přesvědčte, zda je Nepřehlédněte: ruční ovládání vypnuto do polohy 0, abyste zabráni- Před zahájením práce vypněte elektrický proud napájející li nebezpečí úrazu nebo poškození zařízení. komponenty. - V závislosti na napětí musí být elektrické komponenty • Přizpůsobení pro externího pilota (obr. 3a, 3b, 13a a uzemněny podle místních norem a předpisů. 13b, ref. 6) Většina ventilů je vybavena cívkami určenými pro nepřetržitý provoz. Nedotýkejte se solenoidního pohonu, který může • Obecná doporučení pro připojení vzduchu být za normálních provozních podmínek horký, aby nedošlo Potrubí vhodně podepřete a vyrovnejte, aby nedocházelo k úrazu. Pokud je ventil snadno přístupný, musí se montér k mechanickému namáhání ventilu. Při dotahování nepochránit před náhodným kontaktem se solenoidním pohonem. užívejte ventil jako páku. Umístěte klíče co nejblíže k bodu připojení. Abyste zabránili poškození zařízení, NEUTAHUJÚDRŽBA ! Před prováděním jakékoli údržby nebo uváděním do TE PŘÍLIŠ připojení potrubí. provozu ventil vypněte, snižte tlak a odvzdušněte, • Verze s otvory se závitem 1/4“ (obr. 3a), 1/2“ (obr. 3b): abyste zabránili nebezpečí úrazu nebo poškození zařízení. Připojení cívkového ventilu: Verze ATEX: Přísně dodržujte všechny postupy dopoPřipojte potrubí podle označení na štítku: ručené Směrnicí 99/92/EC a přidruženými normami. - Funkce 3/2 NC: Tlakový vstup - otvor 1 (1/4” nebo 1/2” závit). Tlakový • Čištění výstup - otvor 2. Údržba ventilů souvisí s provozními podmínkami. Ventily Výfuk - otvor 3 (1/4” nebo 1/2” závit). se musí pravidelně čistit. Během servisních prací je třeba - Funkce 5/2: zkontrolovat, zda nejsou komponenty nadměrně opotřeTlakový vstup - otvor 1. Tlakový výstup - otvory 2 a 4. beny. Komponenty je třeba vyčistit, pokud zpozorujete Výfuk je veden ventilem do otvorů 3 a 5. zpomalování cyklu, dokonce i tehdy, když je v pořádku tlak v pilotu, nebo v případě zjištění neobvyklého zvuku nebo • Verze s uspořádáním NAMUR (obr. 13a, 13b): netěsnosti. Připojení cívkového ventilu: Připojte potrubí podle označení na štítku: • Emise hluku - Funkce Přesné stanovení hladiny hluku může provést pouze uži-3/2 NC: vatel po nainstalování ventilu do systému. Emise hluku Tlakový vstup - otvor 1 (1/4” nebo 1/2” závit). Tlakový závisí na aplikaci, kapalině a typu použitého vybavení. výstup - otvor 2. Výfuk - otvor 3. • Preventivní údržba (mosazné těleso: 1/8; těleso z nerezavějící oceli: 1/4" nebo - Ventil použijte alespoň jednou měsíčně, abyste zkont1/2" závit). rolovali jeho Výfuk z komor vratné pružiny jednočinného aktuátoru je funkčnost. veden cívkovým ventilem do otvoru 3. Toto je doporučení - Pokud během údržby narazíte na potíže nebo si zajišťující ochranu otvoru 5 (není-li použit). Nepoužívejte nebudete jisti, obraťte se na nás nebo na některého z těsnění. našich autorizovaných zástupců. - Funkce 5/2: Tlakový vstup - otvor 1 (1/4” nebo 1/2” závit). Tlakový výstup - otvory 2 a 4. Výfuk je veden ventilem do otvorů 3 a 5 (mosazné těleso: 1/8; těleso z nerezavějící oceli: 1/4" nebo 1/2" závit). • Odstraňování problémů - Nesprávný výstupní tlak: Zkontrolujte tlak na vstupní straně ventilu. Tlak musí odpovídat hodnotám uvedeným na typovém štítku. Upozornění: Dodržujte minimální hodnotu tlaku pilota 2 bary. Než uvedete ventil opět do provozu, zkontrolujte, zda funguje správně, abyste zabránili úrazu nebo poškození zařízení. Připojení redukcí výfuků (mosazné těleso) Cívkové ventily řady 551 se dodávají dle objednávky s nebo bez miniaturní redukce výfuku 1/8", index M (obr. 13a). Tyto nastavitelné miniaturní redukce výfuku se používají k nastavení provozní rychlosti aktuátoru. Dají se rovněž • Náhradní díly připojit (1/8 závit) tak, aby shromažďovaly výfukové plyny. Cívky jsou k dispozici jako náhradní díly. Montáž / Seřízení (obr. 3a): V případě potřeby vyměňte celý ventil. 27 3834901 Instrukcje instalacyjne i konserwacyjne Seria 551 zawory solenoidowe, korpus z brązu, lub seria 551-553, korpus ze stali nierdzewnej, gwint 1/4", 1/2" lub interfejs NAMUR OPIS ZATWIERDZENIA Wersje, których dotyczy zatwierdzenie (rys. 1 oraz 11). Korpus z brązu (seria 551) lub korpus ze stali nierdzewnej (seria 551, 553), monostabilny (zwrot sprężyny) lub dwustabilny, 3/2 NC (normalnie zamknięta) funkcja lub 5/2, wersja izolowana od atmosfery zewnętrznej. Wersje z lub bez sterowania ręcznego kasującego nastawienie urządzenia przez regulator automatyczny. - z gwintowanymi 1/4 (551) lub 1/2 (553) portami - 551, z połączeniem gwintowanym Ľ”, maks. głębokość portu 11,5 mm. (Nie podłączać zasilania w ciśnienie do portu wyjściowego 3. Konstrukcja “chroniona środowiskowo” nie jest przystosowana do funkcji “dystrybucyjnej” lub wykorzystania BEZ funkcji. Prosimy skontaktować się z nami w sprawie funkcji dostępnych w poszczególnych wersjach). - z interfejsem NAMUR do bezpośredniego montowania do pojedynczego działania (funkcja 3/2 NC) lub podwójnego działania (funkcja 5/2) pneumatycznych urządzeń uruchamiających. Funkcja zaworu jest wymienialna z 3/2 NC na 5/2 poprzez zamontowanie załączonej płyty interfejsowej 3/2 NC lub 5/2 na dnie zaworu (rys. 13a, 13b, ref. 1a oraz 1b). 551, maks. głębokość portu 1/4” = 11,5 mm. (Nie podłączać zasilania w ciśnienie do portu wyjściowego 3. Konstrukcja “chroniona środowiskowo” nie jest przystosowana do wykorzystania BEZ funkcji. Prosimy skontaktować się z nami w sprawie funkcji dostępnych w poszczególnych wersjach). Podłącz rury w zakresie pożądanych funkcji zgodnie z niniejszą dokumentacją oraz oznaczeniami portów na produkcie. - Upewnij się, że do obwodu nie dostały się żadne obce przedmioty mogące zablokować działanie zaworu. Ogranicz użycie taśmy uszczelniającej lub środka uszczelniającego do minimum. - Zawory te są przeznaczone do użytkowania z czystym i suchym powietrzem lub gazem obojętnym. Zalecana filtracja minimalna: 50 mikronów. Punkt rosy użytego płynu musi wynosić przynajmniej -10°C (18°F) poniżej minimalnej temperatury, na której działanie płyn ten może być wystawiony. W przypadku używania naoliwionego powietrza, smar musi być zgodny z użytymi elastomerami. Powietrze instrumentalne zgodnie ze standardem ANSI/ISA S7.3 (1975) przewyższa niezbędne wymagania, i stąd też, jest dopuszczalnym płynem dla tych zaworów. Wszystkie porty wylotowe zaworów i pilotów muszą ! być zabezpieczone ochraniaczami wylotów wykonanymi ze stali nierdzewnej. Podłącz te zabezpieczenia wydmuchów do portu 3 (3/2 NC) lub portów 3 – 5 (5/2) zaworów. W przypadku używania na zewnątrz, lub przechowywania przez dłuższy okres czasu i/lub w przypadku wystawienia na działanie ostrego otoczenia (kurz, płyny, itd.), należy używać zabezpieczeń wydmuchów. Wiarygodność zaworu nie może być zagwarantowania w przypadku używania innego zabezpieczenia wydmuchu niż ten dostarczony. - Dopuszczalny zasięg temperatur: -40°C do +80°C (seria 551); -40°C do +60°C (seria 553). - Zasięg maksymalnego ciśnienia operującego: -2 do 10 barów -2 do 8 barów (ISSC/PISC/PISCIS/CFSCIS/CFSDIS/CFVTIS) OPIS OGÓLNY Wersje ATEX 94/9/WE: Patrz „Specjalne warunki związane z bezpiecznym użytkowaniem” Wersje odizolowane od atmosfery: Wewnętrzne części zaworu są odizolowane od atmosfery zewnętrznej w celu zapewnienia zabezpieczenia w środowiskach agresywnych. Wszystkie porty wydmuchów zaworu szpulowego mają możliwość przyłączenia rur, co zapewnia lepsze zabezpieczenia środowiska, i jest szczególnie rekomendowane w przypadku obszarów delikatnych takich jak czyste pomieszczenia oraz zastosowania w przemysłach farmaceutycznym i przetwarzania żywności. Niezbędne jest podłączenie rur lub instalacji do portów wydmuchów w celu zabezpieczenia części wewnętrznych zaworu szpulowego w momencie użytkowania na zewnątrz lub w środowisku ostrym (kurze, płyny, itd.). SPECJALNE WARUNKI ZWIĄZANE Z BEZPIECZNYM UŻYTKOWANIEM ATEX 94/9/WE: Zawór musi być podłączony do uziemienia (patrz „Montaż”). Maksymalna temperatura płynu nie może przekraczać temperatury otoczenia. Zawór szpulowy musi być przechowywany w opakowaniu oryginalnym tak długo, jak pozostaje on nieużywany. Osłony zabezpieczające nie powinny być usuwane z portów łączeń i operatorów solenoidowych. 3/2 NC 5/2 PL Warunki przechowywania: Zabezpieczone przed wystawieniem na działanie pogody; Temperatura przechowywania: -40 C do +70°C ; wilgotność względna: 95 % Po przechowywaniu w niskiej temperaturze, zawory szpulowe muszą być stopniowo przyzwyczajane do temperatury pokojowej przed utrzymywaniem zwiększonego ciśnienia. Zawory szpulowe są przeznaczone do działania w obrębie technicznych cech charakterystycznych określonych na tabliczce znamionowej. Zmiany w sprzęcie dozwolone są tylko po konsultacji z producentem lub jego przedstawicielem. Te solenoidowe zawory szpulowe są zaprojektowane tak, aby działały z powietrzem przefiltrowanym lub gazem neutralnym. Nie należy przekraczać maksymalnego dozwolonego ciśnienia zaworu = 10 barów (lub 8 barów z zaworem pilotowym Pieztronic dla ATEX EEx ja). Uwaga: Przestrzegaj minimalnego ciśnienia pilota o wartości 2 barów. Instalacja oraz konserwacja zaworu musi być wykonywana wyłącznie przez wykwalifikowany personel. • Standardowe wersje operujące powietrzem o wskaźniku IP65 lub wersje do użytkowania w atmosferach wybuchowych spowodowanych przez gazy, pary, mgły lub pyły zgodnie z Dyrektywą ATEX 94/9/WE. (Klasyfikacja stref dla tej wersji wskazana jest na tabliczce znamionowej ATEX, referencja E1). Kod bezpieczeństwa, seria 551: II 1GD c T6 T85°C Ta -40°C do +65°C Kod bezpieczeństwa, seria 553: II 2GD c T6 (T85°C) - T5 (T100°C) Certyfikat badań WE nr (Seria 551): INERIS 03 ATEX 0219 X Zgodność z Istotnymi Wymaganiami Zdrowotnymi i Bezpieczeństwa została zapewniona poprzez zgodność ze Standardami Europejskimi EN 13463-1 oraz EN 13463-5. • Solenoidowe wersje operujące powietrzem instalowane z solenoidowymi operatorami: - o wskaźniku IP65 lub autoryzowane wersje do użytkowania w atmosferach wybuchowych zgodnie z Dyrektywą ATEX 94/9/WE. • Wersje z solenoidowymi operatorami z płytką mocującą ASCO, o wskaźniku IP65 w ramach standardu, lub do użytkowania w atmosferach wybuchowych II 3D IP65/IP67 lub ATEX EEx d, m, em, ia (Seria 551: II 1G/2D Ex ia IIC IP65/IP67 lub serie 553: II 2G/D Ex ia IIC IP65/IP67). • Wersje z pilotami z płytką mocującą CNOMO E06.05.80 (rozmiar 30) lub CNOMO E06.36.120N (rozmair 15), o wskaźniku IP 65 w ramach standardu, lub zamontowaniu pilotów używanych w atmosferach wybuchowych zgodnie z ATEX EEx d lub Ex ia. Uwaga (piloty CNOMO): Klasyfikacja strefy (ATEX 1999/927 WE) jest głównie zdefiniowana poprzez wskazania znajdujące się na płytce znamionowej rys. 10 oraz 20 (referencja E1 lub E2) na korpusie zaworu. Kod bezpieczeństwa zgodnie z Dyrektywą ATEX 94/9/WE: II 1GD c T6 T85°C Ta -40°C do +65°C Certyfikat badań WE nr INERIS 03 ATEX 0219 X W momencie montowania tego produktu do pilota dla ATEX 94/9/WE, należy przyjąć najmniej korzystną kategorię i temperaturę. Zgodność z Istotnymi Wymaganiami Zdrowotnymi i Bezpieczeństwa została zapewniona poprzez zgodność ze Standardami Europejskimi EN 13463-1 oraz EN 13463-5. Pozycja montowania dla pilotów tak, jak zostało to wskazane na rysunkach 4/5/14/15/21/22/23/24 i wskazane naprężające momenty obrotowe muszą być przestrzegane. W przypadku operatorów solenoidowych oraz pilotów dla ATEX 49/9/WE, instrukcje użytkowania podane w specyficznych Instrukcjach Instalacyjnych dostarczone razem z produktem, muszą być ściśle przestrzegane. MONTAŻ ! Wersje ATEX 94/9/WE: Upewnij się, że wszystkie części metalowe lub przewodzące są zawsze podłączone wzajemnie oraz podłączone do uziemienia. Korpus zaworu jest podłączony do uziemienia przy pomocy śruby mocującej (ref. F). Zawory mogą być montowane w każdej pozycji. Gwintowane wersje portu 1/4 (rys. 3a), 1/2 (rys. 3b): Zamontuj zawór przy użyciu dwóch śrub (ref. 1) (nie dostarczona). Wersje z interfejsem NAMUR (rys. 13a, 13b): Przed zamontowaniem zaworu szpulowego na urządzenie uruchamiającym, należy nastawić je na wymagane działanie: - Wybierz płytę interfejsową, która odpowiada wymaganej funkcji: 3/2 lub5/2 (referencja 1a lub 1b). - Upewnij się, że uszczelka jest właściwie umiejscowiona (ref. 7). - Zamontuj płytę interfejsową pod zaworem szpulową za pomocą 2 dostarczo-nych śrub (ref. 8), przestrzegaj kierunku montowania. Upewnij się, że wska-zówka funkcji umieszczona jest na stronie zwrotnej (gniazdko polaryzujące) 28 3834901 Instrukcje instalacyjne i konserwacyjne Seria 551 zawory solenoidowe, korpus z brązu, lub seria 551-553, korpus ze stali nierdzewnej, gwint 1/4", 1/2" lub interfejs NAMUR - Zainstaluj dwa pierścienie o przekroju okrągłym (ref. 9). - Umieść bolec polaryzujący na urządzeniu uruchamiającym, jeśli okaże się to niezbędne: Gniazdo polaryzujące Ø 5 na płycie interfejsowej 3/2 znajduje się w A1. polaryzujące Ø 5 na płycie interfejsowej 5/2 znajduje się w A2. POŁĄCZENIE PNEUMATYCZNE (rys. 3a, 3b, 13a oraz 13b) W zależności od wersji (3/2 NC lub 5/2), można użyć jedno lub dwa zabezpieczenia wylotu wykonane ze stali nierdzewnej (patrz rys. 2). • Podłączenie wersji z pneumatycznym pilotem: G 1/8 lub NPT 1/8 lub G 1/4 lub NPT 1/4. • Podłączenie wydmuchów pilota Wydmuchy mogą być zbierane zgodnie z użytą wersją. • Sterowanie ręczne kasujące nastawienie urządzenia przez regulator automatyczny W zależności od wersji, produkty dostarczane są z lub bez sterowania ręcznego kasującego nastawienie urządzenia przez regulator automatyczny w celu obsługi bez prądu. Sterowanie ręczne kasujące nastawienie urządzenia przez regulator automatyczny oznaczone jest symbolem ( ) na rys. 4, 5, 14, 15, 21 do 24, i referencja 10 na rys. 3a, 3b, 13a, 13b. Sterowanie ręczne kasujące nastawienie urządzenia przez regulator automatyczny typu impulsowego lub wstrzymanego (typ naciśnij/skręć) wskazane symbolem ( ) na rys. 3a, 3b, 13a oraz 13b pozwala na obsługę bez mocy (prądu). ! Przed uruchamianiem, upewnij się, że sterowanie ręczne kasujące nastawienie urządzenia przez regulator automatyczny ustawiony jest w pozycji odłączającej „0” w celu zapobiegania przed ryzykiem zranienia osób lub uszkodzenia sprzętu. • Przystosowanie do zewnętrznego zasilania pilota (rys.3a, 3b, 13a et 13b, ref. 6) • Ogólne zalecenia w zakresie połączenia pneumatycznego Zabezpiecz we właściwy sposób i wyrównaj (ustaw w szeregu) rury celem zabezpieczenia przed mechnicznym obciążeniem na zaworze. W momencie dokręcania, nie używaj zaworu jako dźwigni; umieść klucze na tyle na ile jest to możliwe przy punkcie złą czania. Aby uniknąć uszkodzenia sprzęty, NIE ZAKRĘCAJ NADMIERNIE połączeń rurowych. • Gwintowane wersje portu 1/4 (rys. 3a), 1/2 (rys. 3b): Podłączenie zaworu szpulowego: Podłącz rury, tak, jak zostało to wskazane na etykiecie: - funkcja 3/2 NC: Wlot ciśnienia przy porcie 1 (gwint 1/4” lub 1/2”). Wylot ciśnienia przy porcie 2. Wylot przy porcie 3 (gwint 1/4” lub 1/2”). - funkcja 5/2: Wlot ciśnienia przy porcie 1. Wyloty ciśnienia przy porcie 2 i 4. Wydmuchy są prowadzone przez zawór do portów 3 i 5. • Wersje z interfejsem NAMUR (rys. 13a, 13b): Podłączenie zaworu szpulowego: Podłącz rury, tak, jak zostało to wskazane na etykiecie: - funkcja 3/2 NC: Wlot ciśnienia przy porcie 1 (gwint 1/4” lub 1/2”). Wylot ciśnienia przy porcie 2. Wylot przy porcie 3. (korpus z brązu: 1/8 ; korpus ze stali nierdzewnej: gwint 1/4" lub 1/2"). Wylot ze zwrotnych komór sprężynowych działającego pojedynczo urządzenia uruchamiającego jest prowadzony poprzez zawór szpulowy do portu 3. Zaleca się ochronę portu 5 (w przypadku, gdy nie jest używany). Nie uszczelniaj go. - funkcja 5/2: Wlot ciśnienia przy porcie 1 (gwint 1/4” lub 1/2”). Wylot ciśnienia przy portach 2 i 4. Wyloty są prowadzone przez zawór do portów 3 i 5. (korpus z brązu: 1/8 ; korpus ze stali nierdzewnej: gwint 1/4" lub 1/2"). Podłączenie reduktorów wylotu (korpus z brązu) Zawory szpulowe srii 551 są dostarczane zgodnie z zamówieniem razem z lub bez małych 1/8” reduktorów wydmuchu, sufiks M (rys. 13a). Te możliwe do regulacji mini reduktory wydmuchu używane są do regulowania szybkości działania urządzenia uruchamiającego. Mogą być one podłączone także (1/8 gwint) w celu zbierania wydmuchów. 3/2 NC 5/2 PL Montaż / Regulacja (rys. 3a): Wersja 3/2 NC = 1 reduktor wydmuchu dopasowany do portu 3 Wersja 5/2 NC = 2 reduktory wydmuchu dopasowane do portów 3 i 5 Umieść śrubę (4) na reduktorze w otworze i dokręć ją; następnie wykręć aby zwiększyć przpływ wydmuchów (nigdy nie wykonuj więcej niż dwa obroty, maksymalny przepływ uzyskany przy jednym obrocie). Dokręć przeciwnakrętkę (4a) za pomocą 13 mm klucza. Dokonaj pobieżnej regulacji przed utrzmywaniem zwiększonego ciśnienia a następnie wykonaj dokładną regulację. PODŁĄCZENIE ELEKTRYCZNE • Wersje z solenoidowymi operatorami z interfejsem ASCO: Patrz dodatkowe instrukcje instalacyjne dostarczone z każdym operatorem solenoidowym. Operator solenoidowy ze wskaźnikiem IP65 (rys. 3a, 3b oraz 13a, 13b): Zamontuj cewkę na rurze (możliwą do obracania w zakresie 360°) a następnie możliwy do usunięcia łącznik ISO 4400/EN 175101-803A (średnica kabla 6 - 10 mm) możliwy do obracania w zakresie 90° (3 kołki: 2 + uziemienie). • Wersje z płytką mocującą CNOMO: Patrz dodatkowe instrukcje instalacyjne dostarczone z każdym zaworem pilotowym. • Ogólne zalecenia: Podłączenia elektryczne muszą być wykonane przez wykwalifikowany personel i zgodnie z mającymi zastosowanie lokalnymi standardami i przepisami. Prosimy o zwrócenie uwagi: - Przed rozpoczęciem jakiejkolwiek pracy, wyłącz prąd elektryczny w celu odłączenia od zasilania wszystkich komponentów. - W zależności od napięcia, komponenty elektryczne muszą być uziemione zgodnie z lokalnymi standardami i przepisami. Większość zaworów jest wyposażona w cewki w celu zapewnienia ciągłej pracy. Aby zapobiec ryzyku zranienia osób, nie należy dotykać solenoidowego operatora, który to może nagrzać się w trakcie normalnych warunków pracy. Jeśli zawór jest łatwo dostępny, instalator musi zapewnić zabezpieczenie przed przypadkowym kontaktem z operatorem solenoidowym. KONSERWACJA ! Przed wykonaniem jakichkolwiek prac konserwatoryjnych lub uruchamianiem, należy odłączyć zasilanie, zmniejszyć ciśnienie i wywietrzyć zawór w celu zapobiegania rycyku zranienia osób lub uszkodzenia sprzętu. Wersje ATEX: Postępuj ściśle zgodnie ze wszystkimi procedurami rekomendowanymi przez Dyrektywę 99/92/WE i związane standardy/normy. • Czyszczenie Konserwacja zaworów jest zależna od warunków pracy urządzenia. Muszą być one czyszczone w regularnych przerwach. Podczas serwisowania, części składowe muszą być sprawdzane pod względem nadmiernego zużycia. Części składowe muszą być czyszczone w momencie zauważenia zwolnienia procesu, nawet wtedy, gdy ciśnienie pilota jest właściwe, lub w przypadku wykrycia niezwykłego hałasu albo przecieku. • Emisja dźwięku Dokładne ustalenie poziomu dźwięku może być przeprowadzone tylko przez użytkownika mającego zawór zainstalowany w swoim systemie. Emisja dźwięku zależy od zastosowania, płynu oraz rodzaju użytego sprzętu. • Konserwacja zapobiegawcza - Uruchamiaj zawór przynajmniej raz na miesiąc, w celu sprawdzenia jego działania. - W przypadku problemów w trakcie konserwacji, lub w razie jakichkolwiek wątpliwości, prosimy o skontaktowanie się z nami lub z jednym z naszych autoryzowanych przedstawicieli. • Rozwiązywanie problemów - Niewłaściwe ciśnienie wyjściowe: Sprawdź ciśnienie po stronie zasilającej zaworu; musi ono odpowiadać wartościom wskazanym na płytce znamionowej. Uwaga: Przestrzegaj minimalnego ciśnienia pilota o wartości 2 barów. Aby uniknąć zranienia osób lub uszkodzenia sprzętu, sprawdzaj, czy zawór działa w sposób prawidłowy zanim ponownie go uruchomisz do działania. • Części zamienne Cewki dostępne są w ramach części zamiennych. Jeśli jest to niezbędne, należy wymienić cały zawór. 29 3834901 Telepítési és karbantartási útmutató 551-es széria: mágnesszelepek, sárgaréz ház, vagy 551–553-as széria: rozsdamentesacél ház, 1/4"-es, 1/2"-es menet vagy NAMUR felület A JÓVÁHAGYÁS LEÍRÁSA A jóváhagyás által érintett változatok (1. és 11. ábra): Sárgaréz ház (551-es széria) vagy rozsdamentesacél ház (551-es, 553-as széria), monostabil (rugós helyretolás) vagy bistabil, 3/2-es NC (nyitó) funkció vagy 5/2-es, környezeti levegőtől elszigetelt változat. Változatok kézi vezérléssel van a nélkül. - 1/4-es (551) vagy 1/2-es (553) menetes nyílások - 551, 1/4” menetes csatlakozással, max. furatmélység 11,5 mm. (A 3. kimeneti csatlakozóra ne csatlakoztassa a nyomó vezetéket. A “környzetvédelmi” felépítésben az “elosztó” funkció nem került megvalósításra vagy NO funkcióval rendelkezik. Az egyes elérhető verziókkal kapcsolatban vegye fel velünk a kapcsolatot). - NAMUR felülettel az egyszeres (3/2-es NC funkció) vagy kétszeres (5/2-es funkció) működésű pneumatikus működtetőszervekre történő közvetlen felszereléshez. A szelep működése átalakítható 3/2-es NC-ről 5/2-esre a mellékelt 3/2-es NC vagy 5/2-es illesztőlemez felszerelésével a szelep aljára (13a., 13b. ábra, 1a. és 1b. pont). 551, max. 1/4” furatmélység = 11,5 mm. (A 3. kimeneti csatlakozóra ne csatlakoztassa a nyomó vezetéket. A “környzetvédelmi” felépítésben a NO funkció nem került megvalósításra. Az egyes elérhető verziókkal kapcsolatban vegye fel velünk a kapcsolatot). Csatlakoztassa a kívánt funkciók csővezetékeit a jelen dokumentációnak és a terméken szereplő nyílásjelzéseknek megfelelően. - Biztosítsa, hogy ne juthasson idegen anyag a körbe, mert az blokkolhatja a szelep működését. A tömítőszalagok és egyéb tömítőanyagok használatát korlátozza minimálisra. - Rendeltetésük szerint ezek a szelepek tiszta és száraz levegővel vagy semleges gázzal használhatók. A javasolt minimális szűrés 50 mikron. A használt közeg harmatpontja legalább 10 °C-kal (18 °F) kisebb legyen annál a minimális hőmérsékletnél, amelynek a közeg ki lehet téve. Kenőanyagot tartalmazó levegő használata esetén a kenőanyagnak kompatibilisnek kell lennie a használt elasztomerekkel. A műszerlevegő az ANSI/ISA S7.3 szabvány (1975) értelmében túlteljesíti a szükséges követelményeket, vagyis elfogadható közeg a szelepek számára. A szelepek és pilotok valamennyi kilépőnyílását ! rozsdamentes acélból készült kiáramlásvédővel kell védeni. Ezeket a kiáramlásvédőket a szelepek 3-as (3/2-es NC) vagy 3–5-ös (5/2-es) nyílására csatlakoztassa. Ha a szelepeket a szabadban használják, hosszabb ideig tárolják, illetve kedvezőtlen körülményeknek (porok, folyadékok stb.) teszik ki, akkor kötelező kiáramlásvédőket használni. A mellékelttől eltérő kiáramlásvédő használata esetén a szelep megbízhatósága nem szavatolható. - Megengedett hőmérséklet-tartomány: -40 - +80 °C (551-es széria); -40 - 60 °C (553-as széria) - Maximális üzeminyomás-tartomány: -2 - 10 bar -2 - 8 bar (ISSC/PISC/PISCIS/CFSCIS/CFSDIS/CFVTIS) ÁLTALÁNOS LEÍRÁS ATEX 94/9/EK változatok: lásd „A biztonságos használat speciális feltételei” című részt. Környezeti levegőtől elszigetelt változatok: A szelepek belső alkatrészei el vannak szigetelve a környezeti levegőtől, ami agresszív környezetben védelmet nyújt számukra. A környezet védelme érdekében az útszelep valamennyi kifúvónyílására csővezeték csatlakoztatható, ami kifejezetten javasolt az érzékeny területeken, például a tiszta helyiségekben, illetve a gyógyszeripari és élelmiszer-feldolgozó ipari alkalmazásokban. A szabadban vagy kedvezőtlen körülmények (por, folyadékok stb.) között használt útszelep belső alkatrészeinek védelmére a kifúvónyílásokra csővezetéket vagy szerelvényt kell csatlakoztatni. A BIZTONSÁGOS HASZNÁLAT SPECIÁLIS FELTÉTELEI ATEX 94/9/EK: a szelepet csatlakoztatni kell a földhöz (lásd: „Szerelés”). A közeg maximális hőmérséklete nem haladhatja meg a környezeti hőmérsékletet. Az útszelepet az eredeti csomagolásában kell tartani mindaddig, amíg használatba nem veszik. A csatlakozónyílásokról és a szolenoidokról nem szabad eltávolítani a védőborítást. Tárolási körülmények: az időjárás hatásaitól védett helyen; tárolási hőmérséklet: -40 – 70 °C; relatív páratartalom: 95% Az alacsony hőmérsékleten tárolt útszelepet fokozatosan 3/2 NC 5/2 HU kell szobahőmérsékletű helyre vinni, mielőtt nyomás alá helyezik. Az útszelepek csupán az adattáblán meghatározott műszaki jellemzők tartományán belül használhatók. A berendezésen csak a gyártóval vagy annak képviselőjével történt egyeztetés után hajthatók végre változtatások. Ezek a mágneses útszelepek szűrt levegővel vagy semleges gázzal használhatók. Ne lépje túl a szelep maximális megengedett nyomását = 10 bar (illetve 8 bar piezotron pilotszelep esetén – ATEX Ex ia). Vigyázat! A minimális pilotnyomás 2 bar. A szelep telepítését és karbantartását csak képzett szakember végezheti. • Szabványos, IP65 védettségű pneumatikus változatok, illetve gázok, gőzök, ködök vagy porok miatt robbanásveszélyes légkörben történő használatra való változatok, a 94/9/EK ATEX irányelv szerint. (Ennek a változatnak a zónabesorolása az ATEX adattáblán szerepel, E1 ref.). Biztonsági előírások, 551-es széria: II 1GD c T6 T85 °C Ta -40 – +65 °C Biztonsági előírások, 553-es széria: II 2GD c T6 (T85 °C) T5 (T100 °C) EC-típusvizsgálati tanúsítvány száma. (551-es széria): INERIS 03 ATEX 0219 X Az alapvető egészségvédelmi és biztonsági követelmények teljesítését a következő európai szabványoknak való megfelelés biztosítja: EN 13463-1 és EN 13463-5. • Mágneses-pneumatikus változatok szolenoidokkal ellátva: - IP65 védettség vagy tanúsítvány a robbanásveszélyes légkörben való használathoz a 94/9/EK ATEX irányelv szerint. • Szolenoiddal ellátott változatok ASCO szerelőlappal: IP65 védettség alapváltozatban, vagy robbanásveszélyes légkörben való használatra: II 3D IP65/IP67 vagy ATEX EEx d, m, em, ia (551-es széria: II 1G/2D Ex ia IIC IP65/IP67 vagy 553-as széria: II 2G/D Ex ia IIC IP65/IP67). • Pilottal ellátott változatok CNOMO E06.05.80 (30-as méret) vagy CNOMO E06.36.120N (15-ös méret) szerelőlappal: IP 65 védettség alapváltozatban, vagy pilotok felszerelése robbanásveszélyes légkörben való használatra az ATEX EEx d vagy Ex ia előírásainak megfelelően. Vigyázat (CNOMO pilotok): A zónabesorolást (ATEX 1999/927EK) elsősorban a szelepház adattábláján (10. és 20. ábra, E1 vagy E2 ref.) szereplő jelzések határozzák meg. Biztonsági előírások a 94/9/EK ATEX irányelv értelmében: II 1GD c T6 T85 °C Ta -40 – +65 °C EC-típusvizsgálati tanúsítvány száma: INERIS 03 ATEX 0219 X Ha ezt a terméket pilotra szereli az 94/9/EK ATEX irányelvnek megfelelően, a legkedvezőtlenebb kategóriát és hőmérsékletet vegye figyelembe. Az alapvető egészségvédelmi és biztonsági követelmények teljesítését a következő európai szabványoknak való megfelelés biztosítja: EN 13463-1 és EN 13463-5. Be kell tartani a pilotszelepek szerelési helyzetét (a 4./5./14./15./21./22./23./24. ábrák szerint), valamint a megadott meghúzási nyomatékokat. A 94/9/EK ATEX irányelv teljesítése érdekében a szolenoidok és pilotok esetében pontosan követni kell a termékhez mellékelt megfelelő telepítési útmutatóban foglalt utasításokat. SZERELÉS ! ATEX 94/9/EK változatok: Valamennyi fém és vezető alkatrésznek mindig össze kell lenniük kapcsolva egymással, és csatlakozniuk kell a földhöz. A szelepházat rögzítőcsavarral kell csatlakoztatni a földhöz (F ref.). A szelepek bármilyen helyzetben felszerelhetők. Menetes nyílású változatok 1/4 (3a. ábra), 1/2 (3b. ábra): A szelepet két csavarral kell felszerelni (1) (nincs mellékelve). Változatok NAMUR felülettel (13a., 13b. ábra): Az útszelepet be kell állítani a kívánt funkciónak megfelelően, mielőtt felszerelnék a működtetőszervre: - Válassza ki a kívánt funkciónak megfelelő illesztőlemezt: 3/2-es NC vagy 5/2-es (1a. vagy 1b.). - Gondoskodjon a tömítés megfelelő elhelyezéséről (7). - Szerelje az illesztőlemezt az útszelep alá a 2 mellékelt csavarral (8), ügyelve a tájolásra. Fontos, hogy a funkció jelzése a visszatérési oldalra kerüljön (polarizálónyílás). - Helyezze fel a két tömítőgyűrűt (9). 30 3834901 Telepítési és karbantartási útmutató 551-es széria: mágnesszelepek, sárgaréz ház, vagy 551–553-as széria: rozsdamentesacél ház, 1/4"-es, 1/2"-es menet vagy NAMUR felület 3/2 NC 5/2 HU - Szükség esetén helyezze a polarizálótűt a működtetőszervre: 3/2-es NC változat = 1 kifúvásreduktort kell a 3. nyílásra A Ø 5 polarizálónyílás a 3/2-es illesztőlemezen az A1-nél szerelni található. 5/2-es változat = 2 kifúfásreduktort kell felszerelni, a 3. és A Ø 5 polarizálónyílás a 5/2-es illesztőlemezen az A2-nél az 5. nyílásra található. Illessze a reduktor csavarját (4) a furatba, és csavarja be PNEUMATIKUS CSATLAKOZTATÁS ütközésig; majd a kifúvás áramának erősítéséhez csavarja (3a., 3b., 13a. és 13b. ábra) kifelé (két fordulatnál ne többet; a max. áramlás egy A változattól (3/2-es NC vagy 5/2-es) függően egy vagy fordulattal elérhető). mindkét rozsdamentesacél kiáramlásvédő használható Szorítsa meg a rögzítőanyát (4a) 13 mm-es kulccsal. (lásd a 2. ábrát). A nyomás alá helyezés előtt végezzen durvabeállítást, majd • A pneumatikus pilotváltozat csatlakoztatása: nyomás alatt finombeállítást. G 1/8 vagy NPT 1/8 vagy G 1/4 vagy NPT 1/4. ELEKTROMOS CSATLAKOZTATÁS • A pilot kifúvónyílásainak csatlakoztatása • Szolenoiddal ellátott változatok ASCO felülettel: tekintse A kifúvott anyag a használt változatnak megfelelően gyűjtmeg az egyes szolenoidok gyártói által mellékelt telepítési hető össze. útmutatókat is. • Kézi vezérlés IP65 védettségű szolenoid (3a., 3b. és 13a., 13b. ábra): A terméket, változattól függően, energiaellátás nélküli műköszerelje a tekercset a csőre (360°-ban elforgatható), majd dést lehetővé tévő kézi vezérléssel vagy a nélkül szállítjuk. A a levehető ISO 4400/EN 175101-803A csatlakozót (6–10 kézi vezérlést a ( ) szimbólum jelzi a 4., 5., 14., 15., 21–24. mm-es kábelátmérő), mely 90°-ban elforgatható (3 érintábrákon, valamint a 10-es pont a 3a., 3b., 13a., 13b. ábrákon. kező: 2 + föld). Az impulzusos vagy folyamatos (gombnyomás/forgatás • CNOMO szerelőlappal ellátott változatok: tekintse meg jellegű) kézi vezérlést a ( ) ) szimbólum jelzi a 3a., 3b., az egyes pilotszelepek gyártói által mellékelt telepítési útmu13a. és 13b. ábrán; ez lehetővé teszi az energiaellátás tatókat is. nélküli működést. • Általános ajánlások: Az elektromos csatlakoztatást képzett szakembernek kell ! Üzembe helyezés előtt a személyi sérülés és a bevégrehajtania, a vonatkozó helyi szabványoknak és előrendezés sérülésének megelőzése érdekében győírásoknak megfelelően. ződjön meg róla, hogy a kézi vezérlés vissza van állítFontos: va kikapcsolt (0) helyzetbe. - Bármilyen munka megkezdése előtt le kell kapcsolni az • Hozzáillesztés a külső pilotellátáshoz (3a., 3b., 13a. és áramellátást a komponensek áramtalanítása érdekében. 13b. ábra 6-os pont) - Az elektromos komponenseket a feszültségtől függően • Általános ajánlások a pneumatikus csatlakoztatáshoz földelni kell, a helyi szabványoknak és előírásoknak A szelep mechanikai feszítésének megelőzése érdekében megfelelően. megfelelően támassza alá és igazítsa be a csöveket. Meg- A legtöbb szelep tartós terheléshez készült tekercsekkel húzáskor ne használja a szelepet feszítőkarként; a kulcsokat rendelkezik. A személyi sérülés kockázaténak elkerülése a lehető legközelebb helyezze a csatlakozási ponthoz. NE érdekében ne érjen a szolenoidhoz, mivel az normál üzemi HÚZZA TÚL a csőcsatlakozásokat, mert megsérülhet a körülmények között felforrósodhat. Ha a szelep könnyen berendezés. megközelíthető helyen van, a szerelőnek a szolenoidot el • Menetes nyílású változatok – 1/4-es (3a. ábra), 1/2-es kell látnia a véletlen érintés megakadályozását szolgáló (3b. ábra): védelemmel. Az útszelep csatlakoztatása: KARBANTARTÁS ! Bármilyen karbantartási munka vagy üzembe helyezés Csatlakoztassa a csöveket a címkén jelzett módon: előtt a személyi sérülés és a berendezés sérülésének - 3/2-es NC funkció: Nyomásbemenet az 1. nyíláson (1/4”-es vagy 1/2”-es megelőzése érdekében kapcsolja le a szelep energiaellámenet) Nyomáskimenet a 2. nyíláson. tását, nyomásmentesítse és eressze le a szelepet. Kifúvás a 3. nyíláson (1/4”-es vagy 1/2”-es menet). ATEX-változatok: pontosan kövesse a 99/92/EK irányelv - 5/2-es funkció: és a kapcsolódó szabványok által ajánlott eljárásokat. Nyomásbemenet az 1. nyíláson. Nyomáskimenet a 2. és • Tisztítás a 4. nyíláson. A szelepek karbantartása az üzemi feltételektől függ. A kifúvandó anyagot a szelep a 3. és az 5. nyíláshoz vezeti. Rendszeres időközönként meg kell őket tisztítani. Szer• Változatok NAMUR felülettel (13a., 13b. ábra): vizeléskor ellenőrizni kell, nem koptak-e el az egyes Az útszelep csatlakoztatása: komponensek. Ezek tisztítást igényelnek, ha a ciklus Csatlakoztassa a csöveket a címkén jelzett módon: lelassult, még akkor is, ha a pilotnyomás megfelelő, és - 3/2-es NC funkció: nem észlelhető semmilyen szokatlan zaj vagy szivárgás. Nyomásbemenet az 1. nyíláson (1/4”-es vagy 1/2”-es menet). • Zajkibocsátás Nyomáskimenet a 2. nyíláson. A zajszint pontos meghatározását csak a szeleppel felKifúvás a 3. nyíláson. szerelt rendszer felhasználója tudja elvégezni. A kibocsá(sárgaréz ház: 1/8 ; rozsdamentesacél ház: 1/4"-es vagy tott zaj függ az alkalmazástól, a közegtől és a használt 1/2"-es menet) berendezés típusától. Az egyszeres működésű működtetőszerv rugó-helyretolási • Megelőző karbantartás kamrájából a kifúvandó anyagot az útszelep a 3. nyíláshoz - Működésének vizsgálatához használja a szelepet legvezeti. Javasolt az 5. nyílást védelemmel ellátni (ha nincs alább egy használatban). Ne tömítse. hónapig. - 5/2-es funkció: - Ha a karbantartás közben probléma merül fel, vagy Nyomásbemenet az 1. nyíláson (1/4”-es vagy 1/2”-es kérdés esetén forduljon hozzánk vagy valamelyik hivatalos képviselemenet). tünkhöz. Nyomáskimenet a 2. és a 4. nyíláson. A kifúvandó anyagot a szelep a 3. és az 5. nyíláshoz • Hibaelhárítás - Nem megfelelő kilépőnyomás: ellenőrizze a nyomást vezeti. a szelep ellátási oldalán; ennek meg kell felelnie az (sárgaréz ház: 1/8 ; rozsdamentesacél ház: 1/4"-es vagy adattáblán szereplő értékeknek. 1/2"-es menet) Vigyázat! A minimális pilotnyomás 2 bar. Kifúvásreduktorok csatlakoztatása (sárgaréz ház) Az 551-es útszelepeket a rendelés alapján miniatűr 1/8”-es Az újbóli üzembe állítás előtt a személyi sérülés és a berendezés sérülésének megelőzése érdekében ellenőrizze, kifúvásreduktorral szállítjuk – M utótag (13a. ábra). Az állítható mini kifúvásreduktorok a működtetőszerv üzemi megfelelően működik-e a szelep. sebességének módosítására szolgálnak. Ezek a kifúvott • Pótalkatrészek anyag összegyűjtése érdekében is csatlakoztathatók (1/8- Tekercsek rendelhetők pótalkatrészként. Szükség esetén az egész szelepet ki kell cserélni. as menet). Szerelés/beállítás (3a. ábra): 31 3834901 RACCORDEMENT ANSCHLUSS GB FR DE COLLEGAMENTO AANSLUITING ES IT NL ANSLUTNING TOIMINNAN NO SE FI LIGAÇÃO DK PT ÓÕÍÄÅÓÇ ÁÍÁËÏÃÁ ÌÅ ÔÇ GR PŘIPOJENÍ PODŁĄCZENIE CSATLAKOZTATÁS CZ PL HU Threaded versions / Versions taraudées / Gewindeausführungen / Versiones roscadas / Versioni filettate / Getapte versies / Gjengede versjoner / Utföranden med gänga / Kierreversiot / Gevind versioner / Versões com rosca / Εκδόσεις με σπείρωμα RACCORDEMENT ANSCHLUSS GB FR DE COLLEGAMENTO AANSLUITING ES IT NL ANSLUTNING TOIMINNAN NO SE FI LIGAÇÃO DK PT ÓÕÍÄÅÓÇ ÁÍÁËÏÃÁ ÌÅ ÔÇ GR PŘIPOJENÍ PODŁĄCZENIE CSATLAKOZTATÁS CZ PL HU Threaded versions / Versions taraudées / Gewindeausführungen / Versiones roscadas / Versioni filettate / Getapte versies / Gjengede versjoner / Utföranden med gänga / Kierreversiot / Gevind versioner / Versões com rosca / Εκδόσεις με σπείρωμα Verze se závitem / Wersje gwintowane / Menetes változatok CONNECTION RACORDAJE TILKOBLING TILSLUGNING CONNECTION RACORDAJE TILKOBLING TILSLUGNING 3/2 NC/NL/NF 12 2 12 3 12 2 12 10 fig. 1 10 14 4 14 3 1 2 5 1 14 12 4 14 3 2 5 1 12 12 5/2 3 3/2 NC/NL/NF 2 12 3 12 2 12 10 10 3 1 4 14 14 12 2 5 fig. 1 14 12 4 14 3 4 2 5 3 14 1 4 2 5/2-5/3 12 5 3 1 1 551 12 12 3 1 14 12 1 2 5 1 553 (1/4) F 551 11,5 mm 1/4 F (1/2) F fig. 3b F 1 1 1 fig. 3a 1 Stainless steel - Acier inox Edelstahl - Acero inoxidable Acciaio inox - Roestvast staal rustfritt - rostfri ruostumatonta - rustfri Aço inoxidável - από ορείχαλκο 90 90 90 F F 90 F F 6 a 1 a 6 1 a a 6 8 3 6 a a 2 1 a 2 10 1 F 2 a 2 a a 1 1 1 3 10 1 3 10 3 10 2 fig. 2 10 10 1 1 0 2 fig. 2 34600484 (M5) 34600418 (G1/8) 34600482 (NPT1/8) 34600419 (G1/4) 34600483 (NPT1/4) 3-4 0 34600418 (G1/8) 34600482 (NPT1/8) 34600479 (G1/2) 34600481 (NPT1/2) 3-4 suitable F F Rep. a N.m 10 ± 2 b fig.5 fig.22 fig.21 b ±2 18 T. amb. T 195 2 Inch.Pounds 88 ± 18 ±2 18 ± 18 fig.10 II1GD c II1GD c 0081 II2GD INERIS 03 ATEX0219X MEDIUM N.m 10 ± 2 b ± 18 fig.10 b T ˚C YEAR bar PIPE MEDIUM T.P.L CATALOGUE N° CATALOGUE N˚ 630 fig.4 2 Rep. a Inch.Pounds 88 ± 18 T. amb. T c BP17 28111 LUCE FRANCE T YEAR bar PIPE MEDIUM T.P.L CATALOGUE N˚ SERIAL No 0081 II2GD INERIS 03 ATEX0219X T. amb. T °C T ˚C YEAR bar PIPE MEDIUM T.P.L CATALOGUE N° SERIAL No SERIAL No BP17 28111 LUCE FRANCE BP17 28111 LUCE FRANCE T. amb. T c T °C YEAR bar PIPE T.P.L SERIAL No BP17 28111 LUCE FRANCE Tamb. E2 R E1 E2 BP17 28111 LUCE FRANCE 32 E1 E2 E1 E2 3834901 E1 33 E2 3834901 RACCORDEMENT ANSCHLUSS GB FR COLLEGAMENTO AANSLUITING ES IT ANSLUTNING TOIMINNAN NO SE LIGAÇÃO DK PT ÓÕÍÄÅÓÇ ÁÍÁËÏÃÁ ÌÅ ÔÇ PŘIPOJENÍ PODŁĄCZENIE CSATLAKOZTATÁS CZ PL NAMUR versions / Versions NAMUR / NAMUR-Ausführungen / Versiones NAMUR / versioni NAMUR / NAMUR-versies / NAMUR-versjoner / NAMUR-utföranden / NAMUR-versiot / NAMUR versioner / Versões NAMUR / Εκδόσεις NAMUR Verze s rozhraním NAMUR / Wersje NAMUR / NAMUR-változatok DE NL FI GR HU CONNECTION RACORDAJE TILKOBLING TILSLUGNING 2 2 4 3 5 4 12 1 3 4 2 5/2 5 1 1 3/2 NC/NL/NF 5 3 12 fig. 11 12 4 5 A2 fig. 13a 4 4a 7 a 1 6 2 2 4 10 4a 3/2 5/2 3 8 1 5 3x 1/4 90 8 7 5 6 A2 1 3 2 1 3x 3 3x 10 5 1/4 4 1 a 2 5 10 1/4 10 1 1 0 2 fig. 2 34600484 (M5) 34600418 (G1/8) 34600482 (NPT1/8) 3-4 suitable 34600418 (G1/8) 34600482 (NPT1/8) 34600419 (G1/4) 34600483 (NPT1/4) 34600479 (G1/2) 34600481 (NPT1/2) 0 (551) 3-4 suitable F Rep. a N.m 10 ± 2 b fig.24 fig.23 9 7 6 a 2 a 2 4a 4 2 F 1 10 1b 9 5/2 a 3 a 2 10 2 b 2 F Inch.Pounds 88 ± 18 ±2 18 ± 18 II2GD c II1GD c T. amb. T T ˚C YEAR bar PIPE MEDIUM T.P.L CATALOGUE N° CATALOGUE N˚ T. amb. T 2 ±2 Inch.Pounds 88 ± 18 18 II1GD c YEAR bar PIPE T.P.L ± 18 fig.20 0081 II2GD INERIS 03 ATEX0219X T °C T. amb. T MEDIUM 195 T ˚C YEAR bar PIPE MEDIUM T.P.L CATALOGUE N° CATALOGUE N˚ SERIAL No SERIAL No BP17 28111 LUCE FRANCE N.m 10 ± 2 b 0081 INERIS 03 ATEX0219X MEDIUM Rep. a fig.14 (551) fig.15 (551) fig.20 b 630 fig. 2 6 4 8 5 A2 8 3 a 3 A2 F A1 2 551 5 1 2 7 52 4 3/2 551 5 4 2 1a F 9 1 3/2 5 2 1b F 1 4 ° 1a 9 8 3 90 F A1 Stainless steel - Acier inox Edelstahl - Acero inoxidable Acciaio inox - Roestvast staal rustfritt - rostfri ruostumatonta - rustfri Aço inoxidável - από ορείχαλκο Nerezavějící ocel Stal nierdzewna rozsdamentes acél 90 3 a 7 3x 1 5 1/4 3 ° a 2 2 F a 8 2 90 F 4 3 a Brass - Laiton Messing - Latón Ottone - Koperen hus - kropp Runko - hus Latão - Ïñåß÷áëêïò Mosaz - Brąz sárgaréz 4a F G1/8 5/2 4 2 9 7 551 2 G1/8 3/2 8 4 5 3 1b 9 551 F A1 3/2 5 2 7 a 5/2 5 1 fig. 13b 1a 3 1 G1/8 3 7 551 F a 5 3 9 3/2 4 1b 551 2 551 5 3 551 3/2 1 G1/8 3 551 - 553 (1/4) 3/2 3 4 12 1 551 9 5/2 A1 a 5/2 1a 5/2 3 2 2 3 1 5/2 5 3 12 fig. 11 12 DE NL FI GR HU 5/2 4 2 3/2 NC/NL/NF RACCORDEMENT ANSCHLUSS GB FR COLLEGAMENTO AANSLUITING ES IT ANSLUTNING TOIMINNAN NO SE LIGAÇÃO DK PT ÓÕÍÄÅÓÇ ÁÍÁËÏÃÁ ÌÅ ÔÇ PODŁĄCZENIE CSATLAKOZTATÁS CZ PL NAMUR versions / Versions NAMUR / NAMUR-Ausführungen / Versiones NAMUR / versioni NAMUR / NAMUR-versies / NAMUR-versjoner / NAMUR-utföranden / NAMUR-versiot / NAMUR versioner / Versões NAMUR / Εκδόσεις NAMUR Verze s rozhraním NAMUR / Wersje NAMUR / NAMUR-változatok CONNECTION RACORDAJE TILKOBLING TILSLUGNING PŘIPOJENÍ SERIAL No BP17 28111 LUCE FRANCE BP17 28111 LUCE FRANCE T. amb. T c T °C YEAR bar PIPE T.P.L SERIAL No BP17 28111 LUCE FRANCE Tamb. E1 E2 34 E1 E2 E1 E2 E2 3834901 E1 R BP17 28111 LUCE FRANCE 35 E2 ASCO JOUCOMATIC SA 32 Av. Albert 1er - BP 312 - 92506 RUEIL Cedex - France Tel. (33) 147.14.32.00 - Fax (33) 147.08.53.85 - http://www.asconumatics.eu 36 3834901 37 3834901
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18

Asco Series 551 Solenoid Valves Manual de usuario

Tipo
Manual de usuario