Kenmore FFET2725PW Guía de instalación

Categoría
Microondas
Tipo
Guía de instalación

Este manual también es adecuado para

1
ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS
(and Optional Electric or Gas Cooktop Combination)
B
A
D
C
H
F
I
G
27 1/4”
(69.2 cm)
2”
(5.1 cm)
Min.
2”
(5.1 cm)
Min.
31”*
(78.7 cm)
31”*
(78.7 cm)
3”
(7.6 cm)
3”
(7.6 cm)
1½” (3.8 cm)
Min.
1½” (3.8 cm)
Min.
2" (5 cm) Wide Wood
Spacer if Needed
Door Open
(see note 2)
Spacer
Electrical
Junction Box
Hole for
Cord
Figure 1
27" and 30" Single Wall Ovens (Double ovens see Figure 2)
PN 807153701 Rev. A (1212)
English – pages 1-8
Español – páginas 9-16
Français -pages 17-24
All dimensions are in inches (cm).
Do not remove spacers (if equipped) on the side walls of the built-in oven. These spacers
center the oven in the space provided. The oven must be centered to prevent excess heat buildup that may
result in heat damage or re.
NOTES:
1. Base must be capable of supporting 150 pounds (68 kg) for 27"
models and 200 pounds (90 kg) for 30" models.
2. Allow at least 21" (53.3 cm) clearance in front of oven for door
depth when it is open.
opening under the appliance
side rails.
5. 30" MODELS ONLY: For a
cutout height (H) greater than
28
5
/
8
" (72.7 cm) you can order
a larger bottom trim through a
Service Center.
3. Dimension G (cutout depth) is critical to
the proper installation of the built-in oven.
If the oven decorative trim does not butt
against the cabinet, or if noise is heard
on convection models, verify dimension
G to assure it is the required depth.
4. For a cutout height greater than 28
1
/
8
"
(71.4 cm) add one 2"(5 cm)
wide wood shim of appropriate
height to each side of the
Printed in U.S.A.
* Suggested distance from oor is 31" (78.7cm).
Minimum required distance is 4 ½" (11.4cm).
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
FOR YOUR SAFETY: Do not store or use gasoline or other ammable vapors
and liquids in the vicinity of this or any other appliance.
Your new wall oven has been designed to t a limited variety of cutout sizes to make the job
of installing easier. The rst step of your installation should be to measure your current cutout
dimensions and compare them to the cutout dimensions chart below for your model. You may
nd little or no cabinet work being necessary.
United States
and Canada
PRODUCT DIMENSIONS
MODEL A B C D
27" (68.6 cm) Wall Oven 27 (68.6) 29 (73.7) 24
5
/
8
(62.5) 24¾ (62.9)
30" (76.2 cm) Wall Oven 30 (76.2) 29 (73.7) 28¼ (71.8) 24¾ (62.9)
CUTOUT DIMENSIONS AND CABINET WIDTH
F G (Min.)
H. Standard Height
(**Others, see notes 4 & 5)
I
MODEL Min. Max. Min.
Max
.
27" (68.6 cm) Wall Oven 24
7
/
8
(63.2) 25¼ (64.1) 23½ (59.7) 27¼ (69.2) 28
5
/
8
(72.7) 27
1
/
8
(68.9) Min
30" (76.2 cm) Wall Oven 28½ (72.4) 29 (73.7) 23½ (59.7) 27¼ (69.2) 28
5
/
8
(72.7) 30
1
/
8
(76.5) Min
2
ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS
(and Optional Electric or Gas Cooktop Combination)
Figure 2
27" AND 30" DOUBLE OVENS (Single Ovens see Figure 1)
Do not remove spacers (if equipped) on the side walls of the built-in oven. These spacers
center the oven in the space provided. The oven must be centered to prevent excess heat buildup that may
result in heat damage or re.
NOTES:
1. Base must be capable of supporting 300 pounds
(136 kg) for 27" models and 375 pounds (170 kg)
for 30" models.
2. Allow at least 21" (53.3 cm) clearance in front of
oven for door depth when it is open.
3. Dimension G (cutout depth) is critical to the
proper installation of the built-in oven. If the oven
decorative trim does not butt against the cabinet,
or if noise is heard on convection models, verify
dimension G to assure it is according to the
required dimension.
4. For a cutout height greater than 49½"
(125.7 cm)
add a 2" (5 cm) wide wood shim of appropriate
height to each side of the opening under the
appliance side rails.
5. 30" MODELS ONLY: For a cutout height (H)
greater than 49
7
/
8
" (126.7 cm) you can order a
larger bottom trim through a Service Center.
All dimensions are in inches (cm).
B
A
D
F
I
H
G
C
48 5/8”
(123.5 cm)
48 5/8”
(123.5 cm)
11½”
(29.2 cm)
11½”
(29.2 cm)
2”
(5.1 cm)
Min.
2”
(5.1 cm)
Min.
3” (7.6 cm)
Max.
3” (7.6 cm)
Max.
1½” (3.8 cm)
Min.
1½” (3.8 cm)
Min.
Door Open
(see note 2)
Hole for
Cable
Electrical
Junction Box
2" (5 cm) Wide Wood
Spacer if Needed
Spacer
PRODUCT DIMENSIONS
MODEL A B C D
27" (68.6 cm) Wall Oven 27 (68.6) 50
7
/
16
(128.1) 24
5
/
8
(62.5) 24¾ (62.9)
30" (76.2 cm) Wall Oven 30 (76.2) 50
7
/
16
(128.1) 28¼ (71.8) 24¾ (62.9)
CUTOUT DIMENSIONS AND CABINET WIDTH
F G (Min.)
H. Standard Height
(**Others, see notes 4 & 5)
I
MODEL Min. Max. Min.
Max.
27" (68.6 cm) Wall Oven 24
7
/
8
(63.2) 25¼ (64.1) 23½ (59.7) 48
7
/
8
(124.1) 49
7
/
8
(126.7) 27
1
/
8
(68.9) Min
30" (76.2 cm) Wall Oven 28½ (72.4) 29 (73.7) 23½ (59.7) 48
7
/
8
(124.1) 49
7
/
8
(126.7) 30
1
/
8
(76.5) Min
3
ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS
(and Optional Electric or Gas Cooktop Combination)
Important Notes to the Installer
1. Read all instructions contained in these installation
instructions before installing the wall oven.
2. Remove all packing material from the oven
compartments before connecting the electrical
supply to the wall oven.
3. Observe all governing codes and ordinances.
4. Be sure to leave these instructions with the
consumer.
5. Oven door may be removed to facilitate installation.
6. THESE OVENS ARE NOT APPROVED FOR
STACKABLE OR SIDE-BY-SIDE INSTALLATION.
Important Note to the Consumer
Keep these instructions with your Owner's Guide for the
local electrical inspector's use and future reference.
IMPORTANT SAFETY
INSTRUCTIONS
Be sure your wall oven is installed and grounded
properly by a quali ed installer or service technician.
This wall oven must be electrically grounded in
accordance with local codes or, in their absence,
with the National Electrical Code ANSI/NFPA No.70-
latest edition in United Sates, or with CSA Standard
C22.1, Canadian Electrical Code, Part 1, in Canada.
Stepping, leaning or sitting on the door
of this wall oven can result in serious injuries and can
also cause damage to the wall oven.
Never use your wall oven for warming or heating
the room. Prolonged use of the wall oven without
adequate ventilation can be dangerous.
The electrical power to the oven must be
shut off while line connections are being made. Failure to
do so could result in serious injury or death.
1. Carpentry
Refer to gure 1 or 2 for the dimensions applicable to
your appliance, and the space necessary to receive the
oven. The oven support surface may be solid plywood
or similar material, however the surface must be level
from side to side and from front to rear.
2. Adjusting Oven Height
Oven height can be adjusted with 2" (5cm) wide wood
shims when needed to t into an existing cabinet
cutout opening, when cutout height exceeds 28
1
/
8
"
(71.4cm) for the single wall oven or 49½"
(125.7cm) for
the double wall oven (see Figure 1 or 2). Place shims
of appropriate height beneath the oven side rails.
3. Electrical Requirements
This appliance must be supplied with the proper
voltage and frequency, and connected to an individual,
properly grounded branch circuit, protected by a circuit
breaker or fuse. To know the circuit breaker or fuse
required by your model, see the serial plate to nd the
wattage consumption and refer to table A to get the
circuit breaker or fuse amperage.
Table A
Observe all governing codes and local ordinances
1. A 3-wire or 4-wire single phase 120/240 or 120/208
Volt, 60 Hz AC only electrical supply is required on a
separate circuit fused on both sides of the line (red
and black wires). A time-delay fuse or circuit breaker
is recommended. DO NOT fuse neutral (white wire).
Only certain cooktop models may be installed over
certain built-in electric oven models. Approved
cooktops and built-in ovens are listed by the MFG
ID number (see the insert sheet included in the
literature package).
NOTE: Wire sizes and connections must conform with
the fuse size and rating of the appliance in accordance
with the American National Electrical Code ANSI/NFPA
No. 70-latest edition, or with Canadian CSA Standard
C22.1, Canadian Electrical Code, Part 1, and local
codes and ordinances.
An extension cord should not be used
with this appliance. Such use may result in a re,
electrical shock, or other personal injury. If you need a
longer power cord you can purchase a 10' (3 m) power
cord kit #903056-9010 by calling the Service Center.
2. These appliances should be connected to the
fused disconnect (or circuit breaker) box through
exible armored or nonmetallic sheathed cable.
The exible armored cable extending from the
appliance should be connected directly to the
junction box. The junction box should be located
as shown in Figure 1 or Figure 2 and with as much
slack as possible remaining in the cable between
the box and the appliance, so it can be moved if
servicing is ever necessary.
3. A suitable strain relief must be provided to attach
the exible armored cable to the junction box.
Appliance
Rating Watts
240V
Protection
Circuit
Recommended
Appliance
Rating Watts
208V
Protection
Circuit
Recommended
Less than
4800W
20A
Less than
4100W
20A
4801W - 7200W
30A
4101W - 6200W
30A
7201W - 9600W
40A or 50A
6201W - 8300W
40A or 50A
9601W and +
50A
8301W and +
50A
4
ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS
(and Optional Electric or Gas Cooktop Combination)
In cold weather shipping and storage
conditions, make sure that oven is in nal location
at least three (3) hours before switching on power.
Switching on power while oven is still cold may
damage the oven controls.
4. Electrical connection
It is the responsibility and obligation of the consumer to
contact a quali ed installer to assure that the electrical
installation is adequate and is in conformance
with the National Electrical Code ANSI/NFPA No.
70-latest edition, or with CSA Standard C22.1,
Canadian Electrical Code, Part 1, and local codes and
ordinances.
Risk of electrical shock (Failure to
heed this warning may result in electrocution or
other serious injury.) This appliance is equipped with
copper lead wire. If connection is made to aluminum
house wiring, use only connectors that are approved
for joining copper and aluminum wire in accordance
with the National Electrical Code and local code and
ordinances. When installing connectors having screws
which bear directly on the steel and/or aluminum
exible conduit, do no tighten screws suf ciently to
damage the exible conduit. Do not over bend or
excessively distort exible conduit to avoid separation
of convolutions en exposure of internal wires.
DO NOT ground to a gas supply pipe. DO NOT
connect to electrical power supply until appliance
is permanently grounded. Connect the ground wire
before turning on the power.
(If your appliance is equipped with a
white neutral conductor.)
This appliance is manufactured with a white neutral
power supply and a frame connected copper wire. The
frame is grounded by connection of grounding lead to
neutral lead at the termination of the conduit, if used in
USA, in a new branch circuit installation (1996 NEC),
mobile home, recreational vehicles, where local code
do not permit grounding trough the neutral (white) wire
or in Canada, disconnect the white and green lead
from each other and use ground lead to ground unit in
accordance with local codes, connect neutral lead to
branch circuit-neutral conductor in usual manner see
Figure 4. If your appliance is to be connected to a 3
wire grounded junction box (US only), where local code
permit connecting the appliance-grounding conductor
to the neutral (white) see Figure 3.
NOTE TO ELECTRICIAN: The armored cable leads
supplied with the appliance are UL-recognized for
connection to larger gauge household wiring. The
insulation of the leads is rated at temperatures much
higher than temperature rating of household wiring.
The current carrying capacity of the conductor is
governed by the temperature rating of the insulation
around the wire, rather than the wire gauge alone.
Where local codes permit connecting the appliance-
grounding conductor to the neutral (white) wire (US
Only) (see gure 3):
1. Disconnect the power supply.
2. In the junction box:
connect appliance and power supply cable wires as
shown in Figure 3.
Electrical Shock Hazard
Electrical ground is required on this appliance.
Do not connect to the electrical supply until
appliance is permanently grounded.
Disconnect power to the junction box before
making the electrical connection.
This appliance must be connected to a grounded,
metallic, permanent wiring system, or a grounding
connector should be connected to the grounding
terminal or wire lead on the appliance.
Do not use a gas supply line for grounding the
appliance.
Failure to do any of the above could result in a re,
personal injury or electrical shock.
Figure 3
3-WIRE GROUNDED JUNCTION BOX
Cable from Power Supply
Black
Wires
Junction
Box
Cable from appliance
Ground Wire
(Bare or Green Wire)
White Wire
(Neutral)
U.L.-Listed Conduit
Connector (or CSA listed)
Red
Wires
White Wire
(Neutral)
5
ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS
(and Optional Electric or Gas Cooktop Combination)
Model and Serial Number Location
The serial plate is located along the interior side trim of
the oven and visible when the door is opened.
When ordering parts for or making inquires about your
oven, always be sure to include the model and serial
numbers and a lot number or letter from the serial plate
on your oven.
Single Wall Oven
Serial Plate Location
Double Wall Oven
Serial Plate Location
If oven is used in a new branch circuit installation
(1996 NEC), mobile home, recreational vehicle, or
where local codes DO NOT permit grounding through
the neutral (white) wire, the appliance frame MUST
NOT be connected to the neutral wire of the 4-wire
electrical system. (see gure 4):
1. Disconnect the power supply.
2. Separate the green (or bare copper) and white
appliance cable wires.
3. In the junction box:
connect appliance and power supply cable wires as
shown in Figure 4.
Figure 4
4-WIRE GROUNDED JUNCTION BOX
Cable from Power Supply
White Wire
Junction Box
Cable from appliance
White Wire
Black
Wires
Red
Wires
Ground Wire
Ground Wire
(Bare or Green
Wire)
U.L.-Listed
Conduit Connector
(or CSA listed)
Heavy Weight Hazard
Use 2 or more people to move and install wall oven.
Failure to follow this instruction can result in injury or
damage to the unit.
5. Cabinet Installation
IMPORTANT
Do not lift the oven by the door handle.
Figure 5
1½" (3.8 cm)
clearance
between unit
1 Unpack the wall oven. Remove the bottom trim
taped on the oven side panel.
2 Find the 2 anti-tip mounting screws included in the
literature package.
3 Insert the oven into the cabinet opening. Slide
oven inward leaving 1½" (3.8 cm) clearance
between the oven and front of cabinet (see Figure
5).
4 Pull the armored cable through the hole for it in the
cabinet and toward the junction box while moving
the appliance inward.
5 Push the oven in and against the cabinet.
6
ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS
(and Optional Electric or Gas Cooktop Combination)
Anti-Tip Mounting Holes
Figure 6
Figure 7
Bottom Trim
Screws
supplied
6 Install the Anti-tip Mounting Screws
The wall oven can tip when the door is
open. The anti-tip mounting screws supplied with the
wall oven must be installed to prevent tipping of the
wall oven and injury to persons.
A. The mounting holes in the side trims may be
used as a template to locate the appliance mounting
screw holes (see gure 6).
B. Use the two screws supplied to x the appliance
to the cabinet.
7 Install the Bottom Trim
IMPORTANT: Bottom trim must be installed for the
oven to function properly. DO NOT operate the oven
without the bottom oven trim installed.
Place the top of the bottom trim over the side trim
tabs on each side of the oven below the oven door
and x it using the 2 screws supplied in the mounting
holes located on each side trim below the oven
frame (see Figure 7).
Tip Over Hazard
A child or adult can tip the oven
and be killed.
• Install the anti-tip device to oven
and/or structure per installation
instructions.
• Ensure the anti-tip device is re-engaged when the
oven is moved.
• Do not operate the oven without the anti-tip device
in place and engaged.
• Failure to follow these instructions can result in
death or serious burns to children and adults.
Refer to the installation
instructions supplied with your
appliance for proper installa-
tion.
Check for proper installation
with a visual check that the
anti-tip screws are present.
Test the installation with light
downward pressure on the
open oven door. The oven
should not tip forward.
Anti-tip mounting holes
7
ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS
(and Optional Electric or Gas Cooktop Combination)
Only certain cooktop models may be installed over
certain built-in electric oven models. Approved cooktops
and built-in ovens are listed by the MFG ID number
and product code (see the insert sheet included in the
literature package and cooktop installation instructions
for dimensions).
G
F
H
36” Min.
(91.4 cm) Min.
Use 3/4” (1.9 cm) plywood, installed on
two runners, ush with toe plate. Base
must be capable of supporting 150
pounds (68 kg) for 27" models and 200
pounds (90 kg) for 30" models.
Cut an opening in wood base minimum 9” x
9” (23 X 23 cm), 2” (5 cm) from left side ller
panel, to route armored cable to junction box.
* If no cooktop is installed directly over
the oven unit, 5” (12.7 cm) maximum
is allowed above the oor.
208/240 Volt junction box
for built-in oven.
Figure 8- TYPICAL UNDER COUNTER INSTALLATION OF A SINGLE ELECTRIC BUILT-IN
OVEN WITH AN ELECTRIC COOKTOP MOUNTED ABOVE
Approx. 3”
(7.5 cm)
Cabinet side ller panels
are necessary to isolate the
unit from adjoining cabinets.
Cabinet side ller height
should allow for installation of
approved cooktop models
To reduce the risk of
personal injury and tip-
ping of the wall oven,
the wall oven must be
secured to the cabi-
net (s) by mounting
screws.
4 1/2” (11.5 cm) Max.*
CUTOUT DIMENSIONS
F.WIDTH G.DEPTH
H.HEIGHT
27" (68.6 cm)
Wall Oven
30" (76.2 cm)
Wall Oven
24
7
/
8
" (63.2 cm) Min.
25¼" (64.1 cm) Max.
28½" (72.4 cm) Min.
29" (73.7 cm) Max.
23½" (59.7 cm) Min.
23½" (59.7 cm) Min.
27¼" (69.2 cm) Min.
28
5
/
8
" (72.7 cm) Max.
27¼" (69.2 cm) Min.
28
5
/
8
" (72.7 cm) Max.
For typical under counter installation of an electric built-in oven see Figure below.
8
ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS
(and Optional Electric or Gas Cooktop Combination)
Figure 9 - TYPICAL UNDER COUNTER INSTALLATION OF A SINGLE ELECTRIC BUILT-IN OVEN
WITH A GAS COOKTOP ABOVE
18”(45.7 cm) Max.
6 1/2” Min.
(16.5 cm)
Flare
Union
4”(10 cm)
120V/60Hz
Grounded
Outlet
Right Side
of Cabinet
(To be
accessible
for shut-off
valve
operation)
Pressure
Regulator
Manual
Shutoff
Valve
Flexible Appliance Conduit
Cabinet sides or
ller panel
Wall Oven Cabinet
5” Max.
(12.7 cm)
Flare
Union
7. Checking Operation
Your model is equipped with an Electronic Oven
Control. Each of the functions has been factory
checked before shipping. However, it is suggested
that you verify the operation of the electronic oven
controls once more. Refer to the Use and Care Guide
for operation.
1. Remove all items from the inside of the oven.
2. Turn on the power to the oven (Refer to your Use &
Care Guide.)
3. Verify the operation of the electronic oven controls:
Bake– Verify that this function makes the oven hot.
20 seconds after turning oven on, open the door and
you should feel heat coming from the oven.
Broil– When the oven is set to BROIL, the upper
element in the oven should become red.
Convection (some models)–When the oven is set for
a convection baking or roasting, both elements cycle
on and off alternately and the convection fan will run.
The convection fan will stop running when the oven
door is opened.
Before You Call for Service
Read the "Before You Call for Service Checklist" and
the "Operating Instructions" in your Use and Care
Guide. It may save you time and expense. The list
includes common occurrences that are not the result of
defective workmanship or materials in this appliance.
Refer to your Use and Care Guide for service phone
numbers.
IMPORTANT NOTE
A cooling fan inside the upper rear part above the
oven (some models) provides cooling of the oven
electrical and electronic components. If the oven
has been operating at high temperatures, the fan
will continue to run after the oven is turned off.
6. Leveling the Wall Oven
1. Install an oven rack in the center of the upper oven
(see Figure 10).
2. Place a level on the rack. Take 2 readings with the
level placed diagonally in one direction and then
the other. Use wood shims under the wall oven to
level if necessary.
3. Repeat in the lower
oven if you have a
double cavity wall
oven. If the level
indicates that the rack
is not level, use wood
shims to reach a
compromise for both
ovens.
Figure 10
9
INSTRUCCIONES DE INSTALACIÓN PARA EL HORNO ELÉCTRICO DE PARED
(Combinado con una cocina eléctrica o de gas facultativa)
B
A
D
C
H
F
I
G
27 1/4”
(69.2 cm)
2”
(5.1 cm)
Min.
2”
(5.1 cm)
Min.
31”*
(78.7 cm)
31”*
(78.7 cm)
3”
(7.6 cm)
3”
(7.6 cm)
1½” (3.8 cm)
Min.
1½” (3.8 cm)
Min.
Espaciador de Madera de 2"
(5 cm) de ancho, si es necesario
Ori cio
para el
Cable
Espaciador
Caja
eléctrica
de empalme
Puerta Abierta
(vea la nota 2)
Figura 1
Hornos simples de Pared de 27" y 30" (Para hornos dobles, ver la Figura 2)
P/N 807153701 (1212) Rev. A
English – pages 1-8
Español – páginas 9-16
Français - pages 17-24
Todas las dimensiones se dan en pulgadas (cm).
No quite los separadores de los muros laterales del horno empotrado. Estos espaciadores
centran el horno en el espacio provisto. El horno debe estar centrado para prevenir una concentración excesiva
de calor que podría resultar en daños por el calor o un incendio.
NOTAS:
1. La base debe poder sostener 150 libras (68 kg) para los modelos 27" y la
base debe poder sostener 200 libras (90 kg) para los modelos 30".
2. Deje por lo menos 21" (53.3 cm) de espacio libre para la
profundidad de la puerta cuando esta abierta.
Imprimido en U.S.A.
28
1
/8" (71,4 cm) agregar una
cuña de madera de 2" (5 cm)
de ancho para lograr la altura
apropiada a cada lado del
ori cio ubicado debajo de los
rieles laterales del accesorio.
* Distancia sugerida desde el suelo es 31" (78.7 cm).
La distancia mínima requerida es 4½" (11.4 cm).
PARA SU SEGURIDAD: No almanece ni utilice gasolina u otros vapores y
líquidos in amables en la proximidad de este o de cualquier otro artefacto.
El primer paso para su instalación debe de ser el de medir las dimensiones de la apertura
y compararlas con las que se indican en el cuadro de dimensiones del hueco de la gura 1.
Posiblemente encontrará que algún trabajo de carpintería será necesario.
LA INSTALACIÓN Y EL SERVICIO DEBEN SER EFECTUADOS POR UN INSTALADOR CALIFICADO.
IMPORTANTE: GUARDE ESTAS INSTRUCCIONES PARA USO DEL INSPECTOR LOCAL DE
ELECTRICIDAD. LEA Y GUARDE ESTAS INSTRUCCIONES PARA REFERENCIA FUTURA.
Estados Unidos
y Canadá
DIMENSIONES DEL APARATO
MODELO A B C D
Horno de pared 27" (68.6cm)
27 (68.6) 29 (73.7) 24
5
/
8
(62.5) 24¾ (62.2)
Horno de pared 30" (76.2cm)
30 (76.2) 29 (73.7) 28¼ (71.8) 24¾ (62.2)
DIMENSIONES DEL HUECO Y ANCHURA DEL ARMARIO
F G (Mín.)
H. Altura estándar
(**Otras, vea notas 4 & 5)
I
MODELO Mín. Máx. Mín.
Máx
.
Horno de pared 27" (68.6cm)
24
7
/
8
(63.2) 25¼ (64.1) 23½ (59.7) 27¼ (69.2) 28
5
/
8
(72.7) 27
1
/
8
(68.9) Mín
Horno de pared 30" (76.2cm)
28½ (72.4) 29 (73.7) 23½ (59.7) 27¼ (69.2) 28
5
/
8
(72.7) 30
1
/
8
(76.5) Mín
3. La dimensión G (profundidad del
corte) está primordial para instalar
correctamente el horno de pared. Si el
adorno del armazón del horno no topa
contra el armario, o si escuche un ruido,
veri que si la dimensión G está en
conformidad con la dimensión requerida.
4. Para un corte de una altura mayor que
5. MODELOS 30" SOLAMENTE: Para un corte de una
altura (H) mayor que 28
5
/
8
" (72.7 cm) puede solicitar
un ajuste inferior más grande a través de un Centro
de Servicio.
10
INSTRUCCIONES DE INSTALACIÓN PARA EL HORNO ELÉCTRICO DE PARED
(Combinado con una cocina eléctrica o de gas facultativa)
Figura 2
HORNOS DOBLES DE 27" Y 30" (Para hornos simples, ver la Figura 1)
Todas las dimensiones se dan en pulgadas (cm).
NOTES:
1. La base debe poder sostener 300 libras (136
kg) para los modelos 27" y la base debe poder
sostener 375 libras (170 kg) para los modelos 30".
2. Deje por lo menos 21" (53.3 cm) de espacio libre
para la profundidad de la puerta cuando esta
abierta.
3. La dimensión G (profundidad del corte) está
primordial para instalar correctamente el horno de
pared. Si el adorno del armazón del horno no topa
contra el armario, o si escuche un ruido, veri que
si la dimensión G está en conformidad con la
dimensión requerida.
4. Para un corte de una profundidad mayor que 49½"
(125.7 cm) agregar una cuña de madera de 2" (5
cm) de ancho para lograr la altura apropiada a cada
lado del ori cio ubicado debajo de los rieles laterales
del accesorio.
5. MODELOS 30" SOLAMENTE: Para un corte de
una altura (H) mayor que 49
7
/
8
" (126.7 cm) una
moldura grande inferior puede ser pedido con su
representante.
No quite los separadores de los muros laterales del horno empotrado. Estos espaciadores
centran el horno en el espacio provisto. El horno debe estar centrado para prevenir una concentración excesiva
de calor que podría resultar en daños por el calor o un incendio.
B
A
D
F
I
H
G
C
48 5/8”
(123.5 cm)
48 5/8”
(123.5 cm)
11½”
(29.2 cm)
11½”
(29.2 cm)
2”
(5.1 cm)
Min.
2”
(5.1 cm)
Min.
3” (7.6 cm)
Max.
3” (7.6 cm)
Max.
1½” (3.8 cm)
Min.
1½” (3.8 cm)
Min.
Puerta Abierta
(vea la nota 2)
Espaciador
Caja eléctrica de
empalme
Ori cio
para el
Cable
Espaciador de Madera
de 2" (5 cm) de ancho, si
es necesario
DIMENSIONES DEL APARATO
MODELO A B C D
Horno de pared 27" (68.6cm)
27 (68.6) 50
7
/
16
(128.1) 24
5
/
8
(62.5) 24¾ (62.2)
Horno de pared 30" (76.2cm)
30 (76.2) 50
7
/
16
(128.1) 28¼ (71.8) 24¾ (62.2)
DIMENSIONES DEL HUECO Y ANCHURA DEL ARMARIO
F G (Mín.)
H. Altura estándar
(**Otras, vea notas 4 & 5)
I
MODELO Mín. Máx. Mín.
Máx.
Horno de pared 27" (68.6cm)
24
7
/
8
(63.2) 25¼ (64.1) 23½ (59.7) 48
7
/
8
(124.1) 49
7
/
8
(126.7) 27
1
/
8
(68.9) Mín
Horno de pared 30" (76.2cm)
28½ (72.4) 29 (73.7) 23½ (59.7) 48
7
/
8
(124.1) 49
7
/
8
(126.7) 30
1
/
8
(76.5) Mín
11
INSTRUCCIONES DE INSTALACIÓN PARA EL HORNO ELÉCTRICO DE PARED
(Combinado con una cocina eléctrica o de gas facultativa)
Notas importantes para el instalador
1. Lea todas las instrucciones contenidas en este
manual antes de instalar el horno.
2. Saque todo el material usado en el embalaje del
compartimiento del horno antes de conectar el
suministro eléctrico o de gas a la estufa.
3. Observe todos los códigos y reglamentos pertinentes.
4. Deje estas instrucciones con el consumidor.
5. La puerta del horno se puede retirar para facilitar la
instalación.
6. ESTE HORNO NO ESTÁ APROBADO PARA LA
INSTALACIÓN APILABLE O DE LADO A LADO.
Nota importante al consumidor
Conserve estas instrucciones y el manual del usuario para
uso del inspector local de electricidad y referencia futura.
INSTRUCCIONES
IMPORTANTES DE SEGURIDAD
Asegúrese de que su horno de pared sea instalado y
puesto a tierra de forma apropiada por un instalador
cali cado o por un técnico de servicio.
Este horno de pared debe ser eléctricamente puesto
a tierra de acuerdo con los códigos locales o, en su
ausencia, con el Código Eléctrico Nacional ANSI/
NFPA No. 70–última edición en los Estados Unidos,
o el Código Eléctrico Canadiense CSA Standard
C22.1, Part 1, en Canadá.
Pisar, apoyarse, o sentarse sobre la
puerta de este horno de pared puede causar serias
lesiones y daños al horno de pared.
Nunca use su horno de pared para calentar una
habitación. El uso prolongado de la estufa sin la
ventilación adecuada puede ser peligroso.
La corriente eléctrica al horno debe
estar apagada mientras se hacen las conexiones
de líneas. Si no se apaga, daños serios o la muerte
podrían resultar.
1. Carpintería
Consulte la Figura 1 o la gura 2 para conocer las
dimensiones pertinentes al modelo de su horno y
al espacio necesario en el que poner el horno. La
super cie donde se va a apoyar el horno debe de ser de
madera contrachapada sólida u otro material similar y,
sobre todo, la super cie tiene que estar a nivel, de lado
a lado, y de atrás hacia adelante.
2. Ajuste de la altura del horno
La altura del horno se puede ajustar con cuñas de
madera de 2" (5 cm) de ancho, donde sea necesario,
para que quepa en un gabinete o abertura existente,
cuando la altura del corte es superior a 28
1
/
8
" (71,4 cm)
en el caso del horno único de pared o 49½” (125.7 cm)
en el caso del horno doble de pared (ver la Figura 1 o
2). Colocar las cuñas de altura apropiada debajo de los
rieles laterales del horno.
3. Requerimientos Eléctricos
Se debe proveer el voltaje y la frecuencia apropiados a
este electrodoméstico, y conectarse a un circuito individual
correctamente puesto a tierra, protegido por un interruptor
o un fusible. Para conocer el interruptor o fusible que
requiere su modelo, vea la placa serial para encontrar
la consumación del vatiaje y re érase al cuadro A para
encontrar el amperaje del interruptor o fusible.
Observe todos los códigos que gobiernan y ordenanzas
locales
Table A
1. Un cable de 3 o 4 alambres monofásico 120/240 o
120/208 voltios, 60 hertzios es la única fuente eléctrica
que requiere en un circuito separado en ambos lados de
la línea (alambre negro y alambre rojo) (se recomienda
un fusible o un interruptor de retraso de tiempo). No
funda a cable neutro (alambre blanco). Se debe de
tener precaución al combinar un horno de pared y una
cubierta, re érase a la placa de seria de cada uno de
los aparatos.
NOTA: Los tamaños y las conexiones del alambre deben
conformarse con el tamaño del fusible y el grado de la
aplicación de acuerdo con el código Eléctrico Nacional
Americano ANSI/NFPA No. 70- ultima edición, o con
el estándar CSA canadiense C22.1, código eléctrico
canadiense, parte 1, y códigos y ordenanzas locales.
No se debera usar extensiones para
enchufar este electrodoméstico. Esto podría causar
un incendio, choque eléctrico u otro tipo de daño
personal. Si usted necesita un cable mas largo, puede
ordenar un cable de 10" kit 903056-9010 llamando al
centro de Servicio.
2. Este electrodoméstico debe conectarse a la caja
de fusibles (o de cortocircuito), por medio de un
cable blindado exible o un cable con forro no
metálico. El cable blindado exible que va desde
el electrodoméstico debe de estar conectado
directamente a la caja de empalme. La caja de
empalme debe de estar localizada en el lugar
que se indica en la Figura 1 o 2, dejando tanto
exceso de cable como sea posible entre la
caja y el electrodoméstico, de forma que así el
electrodoméstico se pueda mover fácilmente, si fuera
necesario para hacer una reparación.
3. Se debe de usar un conector que reduzca la tirantez
de una forma adecuada para unir el cable blindado
exible a la caja de empalme.
Grados de
Vatios del
lectrodoméstico
240V
Se
recomienda
una
protección al
circuito
Grados de
Vatios del
lectrodoméstico
208V
Se
recomienda
una
protección al
circuito
Menos de
4800W
20A
Menos de 4100W
20A
4801W - 7200W
30A
4101W - 6200W
30A
7201W - 9600W
40A o 50A
6201W - 8300W
40A o 50A
9601W and +
50A
8301W and +
50A
12
INSTRUCCIONES DE INSTALACIÓN PARA EL HORNO ELÉCTRICO DE PARED
(Combinado con una cocina eléctrica o de gas facultativa)
En cuanto a las condiciones de
despacho y almacenamiento en el invierno, asegúrese
de que el horno llegue a su destino nal como mínimo
tres (3) horas antes de encenderlo. Si se enciende
el horno cuando aún está frío, se pueden dañar los
controles.
4. Conexión eléctrica
El usuario tiene la responsabilidad personal y obligación
de utilizar un instalador cali cado, para asegurar que la
instalación eléctrica está hacha de forma adecuada y está
conforme con el Código Eléctrico Nacional ANSI/NFPA
No. 70-última edición en los Estados Unidos, o el Código
Eléctrico Canadiense CSA Standard C22.1, Part 1, en
Canadá.
Riesgo de choque eléctrico
(El no prestar atención a esta advertencia puede
resultar en electrocución u otras lesiones graves.) Este
electrodoméstico está equipado con alambre de cobre.
Si se va a conectar con cableado de aluminio del hogar,
utilizar únicamente conectores que están aprobados
para unir cobre y aluminio de acuerdo al Código
Nacional Eléctrico (NEC por sus siglas en ingles) y leyes
y códigos locales. Al instalar conectores con tornillos que
empujen directamente contra el acero y/o aluminio del
conducto exible, no apretar los tornillos su cientemente
que dañen el conducto exible. No doblar de más o
deformar el conducto exible para evitar separar el
espiral y descubrir los alambres internos.
NO conecte el alambre puesto a tierra a una tubería de
suministro de gas. NO conecte el suministro de energía
eléctrica hasta que el electrodoméstico haya sido
permanentemente puesto a tierra. Conecte el alambre
de puesto a tierra antes de enchufar por primera vez el
electrodoméstico.
Riesgo de choque eléctrico
• Una puesta a tierra se requiere en este aparato.
• No lo conecte a la corriente eléctrica hasta que el
aparato haya sido puesto a tierra.
• Desconecte la corriente eléctrica a la caja de
empalmes antes de hacer la conexión eléctrica.
• Este aparato debe estar conectado con un sistema
de alambres puesto en tierra, metálico y permanente
o un conector de puesta a tierra debe conectarse al
terminal de puesta a tierra o el alambre conductor
en al aparato.
• No utilice el suministro de gas para hacer la puesta
a tierra.
La falta de cualquiera de las instrucciones
mencionadas podría resultar en un incendio, choque
eléctrico o lesiones personales.
Figura 3 - CAJA DE EMPALMES
DE 3 ALAMBRES PUESTA A TIERRA
Cable desde el suministro de energía
Cable de la estufa
Alambre
desnudo
Alambre
rojos
Caja de
empalmes
Conductor de
unión listado-UL
(o CSA)
Alambre verde
o desnudo
Alambre
desnudo
Alambre
negros
(
Si su electrodoméstico está equipado
con un conductor neutro blanco.)
Este electrodoméstico está fabricado con un suministro
eléctrico neutro blanco y un alambre de cobre
conectado al armazón. El armazón esta puesto a tierra
por un enlace de la conexión a tierra con la conexión
del neutro al nal de la línea eléctrica, si es usado en
los estados unidos una nueva instalación de circuito
de bifurcación (1996 NEC), casa rodante, vehículos
recreacionales, o donde los códigos locales no permitan
poner a tierra mediante el neutro (blanco) o en Canadá,
desconectar la conexión blanca de la verde y utilizar
la conexión a tierra para poner a tierra la unidad de
acuerdo a los códigos locales, conectar el neutro al
circuito de bifurcación- conductor neutro de manera
usual. Ver Figura 4. Si su electrodoméstico va a ser
conectado a una caja de conexión puesta a tierra de
3 cables (en los estados unidos solamente), donde
los códigos locales permitan conectar el conductor de
poner a tierra-electrodoméstico con el neutro (blanco)
ver Figura 3.
NOTA AL ELECTRICISTA: Los conductores de cable
blindados provistos con este artefacto son aprobados
por UL para la conexión al alambrado de casa de un
calibre mayor. El aislamiento de los conductores está
cali cado para temperaturas más altas que las del
alambrado de la casa. La capacidad de corriente del
conductor está gobernada por la cali cación de la
temperatura del aislamiento alrededor del alambre en
vez de solamente el calibre del alambre.
Donde los códigos locales permitan conectar el
conductor de puesta a tierra del electrodoméstico al
neutral (blanco) (Solamente en los Estados Unidos)
(vea gura 3):
1. Desconecte el suministro eléctrico.
2. En el caja de juntas: conectar el aparato y los
cables residenciales como se muestra en la gura
3.
13
INSTRUCCIONES DE INSTALACIÓN PARA EL HORNO ELÉCTRICO DE PARED
(Combinado con una cocina eléctrica o de gas facultativa)
Ubicación del número de modelo y de serie
La placa con el número de serie está ubicada en la
guarnición interior lateral del horno y se puede ver cuando
se abre la puerta.
Cuando haga pedidos de repuestos o solicite información
con respecto a su horno, esté siempre seguro de incluir el
número de modelo y de serie y el número o letra del lote
de la placa de serie de su horno.
Modelos con un solo horno-
la placa de serie está ubicada
aquí.
Modelos con un horno
doble- la placa de serie está
ubicada aquí.
Si el horno se usa en una instalación de circuito de
ramal nuevo (1996 NEC), en una casa rodante, en un
vehículo para recreación o si los códigos locales NO
permiten la conexión a tierra a través del cable neutral
(blanco),
el armazón del electrodoméstico NO TIENE
QUE estar conectado al alambre neutro del sistema
eléctrico de 4 alambres. (ver gura 4):
1. Desconecte el suministro eléctrico
2. Separe el alambre verde (o cobre desnudo) y el
alambre blanco del electrodoméstico.
3. En el caja de juntas: conectar el aparato y los cables
residenciales como se muestra en la gura 4.
Figura 4- CAJA DE EMPALMES
DE 4 ALAMBRES PUESTA A TIERRA
Alambre
desnudo
Cable desde el suministro de energía
Alambre verde
o desnudo
Cable de la estufa
Caja de
empalmes
Conductor de
unión listado-UL
(o CSA)
Alambre
blanco
Alambre
rojos
Alambre
negros
Alambre blanco
5. Instalación del Gabinete
IMPORTANTE
No levante el horno por la manija de la puerta.
3 Insertar el horno en la abertura del gabinete. Deslizar
el horno hacia dentro dejando 1½” (3,8 cm) de
espacio libre entre el horno y la parte delantera del
gabinete (ver la Figura 5).
4 Empujar el cable blindado a través del ori cio del
gabinete y hacia la caja de paso mientras se desliza
el accesorio hacia adentro.
5 Empujar el horno hacia adentro y en contra del
gabinete
Peligro de Peso Pesado
Use 2 personas o más para mover e instalar el horno
de pared.
Si no cumple con esta instrucción, puede resultar en
lesiones personales o daños al horno de pared
1 Desembalar el horno de pared. Extraer la guarnición
inferior y los 2 tornillos unidos con cinta al panel
lateral del horno.
2 Buscar los tornillos que se incluyen en el paquete de
literatura.
Figura 5
1 1/2" (3.8 cm)
distancia entre la
unidad y el gabinete
14
INSTRUCCIONES DE INSTALACIÓN PARA EL HORNO ELÉCTRICO DE PARED
(Combinado con una cocina eléctrica o de gas facultativa)
Figura 7
Guarnición
Inferior
Tornillos
provistos
6 Instalación de los tornillos de montado
El horno de pared puede inclinarse
cuando la puerta esta abierta. Los soportes de
montaje que vienen con el horno de pared deben
de estar ajustadas al armario y al aparato para
evitar que el horno de pared se incline y ocasione
quemaduras graves.
A. Los barrenos en las molduras laterales pueden
ser usadas como guía para localizar los tornillos
de montado de la unidad ( gura 6).
B. Use los dos tornillos proporcionados para
colocar la unidad en la cabina.
Tornillos de montado
Figura 6
7 Instalación de la Guarnición Inferior:
Colocar la parte superior de la guarnición inferior
sobre las lengüetas laterales del horno, debajo de
la puerta del horno, y jarlas usando los 2 tornillos
provistos con los ori cios de montaje ubicados a
cada lado del marco del horno (ver la Figura 7).
IMPORTANTE: La moldura inferior debe estar
instalada para que el horno funcione correctamente.
NO ponga el horno en funcionamiento sin que esté
instalada la moldura del fondo del horno.
Riesgo de volcamiento
• Un niño o adulto puede volcar el
horno y acabar muerto.
• Instale el dispositivo antivuelco
en el horno y/o en la estructura
según las instrucciones de
instalación.
Asegúrese de que el horno se vuelva a acoplar al
dispositivo antivuelco cuando lo mueva.
• No utilice el horno sin el dispositivo antivuelco
instalado y acoplado.
• Si no se siguen estas instrucciones, se puede
provocar la muerte o quemaduras graves en niños y
adultos.
Agujeros de instalación
del dispositivo
antivuelco
Consulte las instrucciones de
instalación proporcionadas
con su electrodoméstico para
instalarlo adecuadamente.
Verifique que la instalación se
haya realizado adecuada-
mente corroborando que los
tornillos antivuelco estén
colocados.
Pruebe la instalación ejercien-
do poca presión hacia abajo
sobre la puerta abierta del
horno. El horno no debe
inclinarse hacia adelante.
15
INSTRUCCIONES DE INSTALACIÓN PARA EL HORNO ELÉCTRICO DE PARED
(Combinado con una cocina eléctrica o de gas facultativa)
G
F
H
36” Min.
(91.4cm) Min.
* Si no se instala ninguna tapa
de cocina directamente sobre la
unidad del horno, se permite un
espacio máximo de 5" (12,7 cm)
sobre el piso.
Figura 8 – INSTALACIÓN TÍPICA DEBAJO DE LA MESADA DE HORNO SIMPLE EMPOTRADO
CON TAPA DE COCINA MONTADA
Approx. 3”
(7.5 cm)
4 1/2” (11.5 cm) Max.*
Instale contrachapado de 3/4" (1.9 cm)
sobre dos correderas, nivelado con la
parrilla inferior. La base debe poder
sostener 150 libras (68 kg) para los
modelos 27"y 200 libras (90 kg) para los
modelos 30".
Corte una abertura de 9" X 9"(23 cm X 23 cm)
(mínimo) en el fondo del contrachapado, a 2" (5
cm) del lado izquierdo del panel llenador, para
poder encaminar el cable a la caja de empalme.
208/240 caja de empalme
para hornos de pared
Los paneles de relleno laterales
del gabinete son necesarios para
aislar la unidad de los gabinetes
adyacentes. La altura del relleno
lateral del gabinete debe permi-
tir la instalación de modelos de
tapas de cocina aprobados.
27" (68.6 cm)
Horno de pared
30" (76.2 cm)
Horno de pared
DIMENSIONES DE ABERTURA
F. ANCHURA
24
7
/
8
" (63.2 cm) Min.
25¼" (64.1 cm) Max.
28½" (72.4 cm) Min.
29" (73.7 cm) Max.
G. PROFUNDIDAD
23½" (59.7 cm) Min.
23½" (59.7 cm) Min.
H. ALTURA
27¼" (69.2 cm) Min.
28
5
/
8
" (72.7 cm) Max.
27¼" (69.2 cm) Min.
28
5
/
8
" (72.7 cm) Max.
Sólo ciertos modelos de tapas de cocina se pueden instalar
sobre ciertos modelos de hornos eléctricos empotrados. Las
tapas de cocina y los hornos empotrados se mencionan por su
número de identi cación MFG ID y código de producto (ver la
planilla que se incluye en el paquete de literatura y las instruc-
ciones de instalación de la cocina donde están detalladas las
dimensiones).
Para reducir el riesgo
de lesiones personales
y inclinación del horno
de pared, éste debe
asegurarse a los
gabinetes mediante
soportes de montaje.
Para una instalación típica de un horno eléctrico incorporado debajo del mostrador, véase la gura 8.
16
INSTRUCCIONES DE INSTALACIÓN PARA EL HORNO ELÉCTRICO DE PARED
(Combinado con una cocina eléctrica o de gas facultativa)
7. Veri cación del funcionamiento
Su modelo está equipado con un Control Electrónico de
Horno. Cada una de las funciones ha sido controlada en
fábrica antes del despacho. Sin embargo, le sugerimos
veri car el funcionamiento de los controles electrónicos
una vez más. Consulte la Guía de Uso y Cuidado o la
Guía del controles para ver el funcionamiento del horno.
1. Extraer todos los elementos de la parte interior del
horno.
2. Encender el horno (Consular la Guía de Uso y
Cuidado.)
3. Veri car el funcionamiento de los controles
electrónicos del horno:
Hornear – Veri car que esta función caliente el horno.
Veinte minutos después de encender el horno, abrir la
puerta y ver si se siente que el calor emana desde su
interior.
Asar– Cuando se pone el horno para asar, el
elemento de arriba del horno debe de ponerse rojo.
Convección (algunos modelos) – Cuando se con gura
el horno para horneado o asado por convección,
los dos elementos se encienden y apagan en forma
alterna y se enciende el ventilador. El ventilador de
convección dejará de funcionar cuando se abre la
puerta del horno durante el horneado o asado por
convección.
Antes de llamar al servicio
Lea la sección Lista de Control de Averías en su
Manual del Usuario. Esto le podrá ahorrar tiempo
y gastos. Esta lista incluye ocurrencias comunes
que no son el resultado de defectos de materiales o
fabricación de este artefacto.
Lea la garantía y la información sobre el servicio en
su Manual del Usuario para obtener el número de
teléfono gratuito.
IMPORTANTE
Un ventilador ubicado dentro de la parte trasera
superior arriba del horno (en algunos modelos)
permite la refrigeración de los componentes
eléctricos y electrónicos de enfriamiento.
Si el horno ha estado funcionando a altas
temperaturas, el ventilador seguirá funcionando
después de apagar el horno.
6. Asegúrese de que el horno de pared está a
nivel
1. Instale una rejilla al centro del horno superior (vea la
Figura 10).
2. Ponga un nivel por encima de la rejilla. Lea 2 veces,
una vez con el nivel a la posición de lado a lado, y otra
vez de atrás hacia adelante. Utilice trozo de madera
o cuñas por debajo del horno de pared para nivelar,
si sea necesario.
3. Vuelve a empezar
en el horno inferior.
Si el nivel muestra
que la rejilla no esta
a nivel, utilice trozo
de madera o cuñas
para componer
ambos hornos.
Figura 10
Figura 9 - INSTALACIÓN TÍPICA PARA UNA ESTUFA DE GAS ENCIMA
DE UN HORNO DE PARED INSTALADO DEBAJO DEL MOSTRADOR
18”(45.7 cm) Max.
6 1/2” Min.
(16.5 cm)
Adaptor
de gas
4”(10 cm)
Tomacorriente
puesto a tierra
de 120Voltios
/60Hz
Lado
derecho del
gabinete
(para tener
acceso a
la válvula
de cierre
manual)
Regulador
de presión
Válvula
de cierre
manual
Conector exible para artefactos
Lados del gabinete
o panel llenador
Gabinete del horno de pared
5” Max.
(12.7 cm)
Adaptor
de gas
ESTUFA DE GAS
17
INSTRUCTIONS D'INSTALLATION POUR FOUR ENCASTRÉ ÉLECTRIQUE
(Combiné à une table de cuisson électrique ou à gaz (en option))
B
A
D
C
H
F
I
G
27 1/4”
(69.2 cm)
2”
(5.1 cm)
Min.
2”
(5.1 cm)
Min.
31”*
(78.7 cm)
31”*
(78.7 cm)
3”
(7.6 cm)
3”
(7.6 cm)
1½” (3.8 cm)
Min.
1½” (3.8 cm)
Min.
Entretoise de bois de 2"
(5 cm) de largeur si nécessaire
Porte ouverte
(voir note 2)
Entretoise
Boîte de
jonction
Ouverture
pour la
sortie du
câble
Figure 1
Fours encastrés simples 27" et 30" (Pour les fours encastrés doubles voir la gure 2)
PN 807153701 (1212) Rev. A
English – pages 1-8
Español – páginas 9-16
Français – pages 17-24
Toutes les dimensions sont en pouces (cm).
N’enlevez pas les entretoises sur les parois latérales du four. Ces entretoises centrent le four dans
l’espace fourni. Le four doit être centré pour prévenir une accumulation excessive de chaleur pouvant causer un feu ou
des dommages.
NOTE:
1. La base doit pouvoir supporter 150 lbs (68 kg) pour les modèles 27" et
200 lbs (90 kg) pour les modèles 30".
2. Allouez au moins 21" (53.3 cm) d'espace à l'avant du four pour
permettre l'ouverture complète de la porte du four.
3. La dimension G (profondeur du
découpage) est critique pour une
bonne installation du four. Si la moulure
inférieure du four ne vient pas s'accoter
contre l'armoire, ou si un bruit se fait
entendre sur les modèles à convection,
véri ez la dimension G pour vous assurer
qu'elle est correcte.
4. Si la hauteur de découpage est
plus grande que 28
1
/
8
" (71.4
cm), ajoutez une entretoise de
bois de 2" (5 cm) de largeur et
Imprimé au U.S.A.
de hauteur appropriée de chaque côté de
l'ouverture sous l'appareil.
5. MODÈLES 30" SEULEMENT: Si la hauteur de découpage
(H) est plus grande que 28
5
/
8
" (72.7 cm), vous pouvez
commander une assiette plus bas à travers un centre de
service.
* La distance suggérée du plancher est 31" (78.7 cm).
La distance minimale requise est 4
1
/
2
" (11.4 cm).
L’INSTALLATION ET L’ENTRETIEN DOIVENT ÊTRE EFFECTUÉS PAR UN INSTALLATEUR QUALIFIÉ.
IMPORTANT: CONSERVEZ POUR L’INSPECTEUR D’ÉLECTRICITÉ LOCAL.
LISEZ ET CONSERVEZ CES INSTRUCTIONS POUR RÉFÉRENCES ULTÉRIEURES.
POUR VOTRE SÉCURITÉ: N’entreposez pas ou n’utilisez pas
d’essence ou d’autres produits in ammables à proximité de cet appareil ou de tout autre
appareil électroménager.
Votre nouveau four encastré a été conçu pour s’ajuster à différentes dimensions de
découpage et en faciliter l’installation. La première étape de votre installation consiste
à mesurer les dimensions du découpage actuel et, à les comparer au tableau de
dimensions de découpage ci-dessous. Vous découvrirez peut-être que peu ou pas de
modi cation sera nécessaire.
États-Unis et Canada
DIMENSIONS DE L'APPAREIL
MODÈLE A B C D
27" (68.6 cm) 27 (68.6) 29 (73.7) 24
5
/
8
(62.5) 24¾ (62.2)
30" (76.2 cm) 30 (76.2) 29 (73.7) 28¼ (71.8) 24¾ (62.2)
DIMENSIONS DE DÉCOUPAGE ET DE L'ARMOIRE
F G (Min.)
H. Hauteur standard
(**autres, voir notes 4 & 5)
I
MODÈLE Min. Max. Min.
Max
.
27" (68.6 cm) 24
7
/
8
(63.2) 25¼ (64.1) 23½ (59.7) 27¼ (69.2) 28
5
/
8
(72.7) 27
1
/
8
(68.9) Min
30" (76.2 cm) 28½ (72.4) 29 (73.7) 23½ (59.7) 27¼ (69.2) 28
5
/
8
(72.7) 30
1
/
8
(76.5) Min
18
INSTRUCTIONS D'INSTALLATION POUR FOUR ENCASTRÉ ÉLECTRIQUE
(Combiné à une table de cuisson électrique ou à gaz (en option))
Figure 2
Fours encastrés doubles 27" et 30" (Pour les fours encastrés simples voir la gure 1)
N’enlevez pas les entretoises sur les parois latérales du four. Ces entretoises centrent le four
dans l’espace fourni. Le four doit être centré pour prévenir une accumulation excessive de chaleur pouvant
causer un feu ou des dommages.
Toutes les dimensions sont en pouces (cm).
NOTES:
1. La base doit pouvoir supporter 300 lbs (136 kg)
pour les modèles 27" et 375 lbs pour les modèles
30".
2. Allouez au moins 21" (53.3 cm) d'espace à l'avant
du four pour permettre l'ouverture complète de la
porte du four.
3. La dimension G (profondeur du découpage) est
critique pour une bonne installation du four. Si la
moulure inférieure du four ne vient pas s'accoter
contre l'armoire, ou si un bruit se fait entendre sur
les modèles à convection, véri ez la dimension G
pour vous assurer qu'elle est correcte.
4. Si la hauteur de découpage est plus grande que
49½"
(125.7 cm), ajoutez une entretoise de bois
de 2" (5 cm) de largeur et de hauteur appropriée
de chaque côté de l'ouverture sous l'appareil.
5. MODÈLES 30" SEULEMENT: Si la hauteur de
découpage (H) est plus grande que 49
7
/
8
" (126.7
cm), vous pouvez commander une moulure
inférieure plus large en contactant un Centre de
service.
B
A
D
F
I
H
G
C
48 5/8”
(123.5 cm)
48 5/8”
(123.5 cm)
11½”
(29.2 cm)
11½”
(29.2 cm)
2”
(5.1 cm)
Min.
2”
(5.1 cm)
Min.
3” (7.6 cm)
Max.
3” (7.6 cm)
Max.
1½” (3.8 cm)
Min.
1½” (3.8 cm)
Min.
Entretoise
Entretoise de bois de 2" (5
cm) de largeur si nécessaire
Boîte de jonction
Ouverture
pour la
sortie du
câble
Porte ouverte
(voir note 2)
DIMENSIONS DE L'APPAREIL
MODÈLE A B C D
27" (68.6 cm) 27 (68.6) 50
7
/
16
(128.1) 24
5
/
8
(62.5) 24¾ (62.2)
30" (76.2 cm) 30 (76.2) 50
7
/
16
(128.1) 28¼ (71.8) 24¾ (62.2)
DIMENSIONS DE DÉCOUPAGE ET DE L'ARMOIRE
F G (Min.)
H. Hauteur standard
(**autres, voir notes 4 & 5)
I
MODÈLE Min. Max. Min.
Max
.
27" (68.6 cm) 24
7
/
8
(63.2) 25¼ (64.1) 23½ (59.7) 48
7
/
8
(124.1) 49
7
/
8
(126.7) 27
1
/
8
(68.9) Min
30" (76.2 cm) 28½ (72.4) 29 (73.7) 23½ (59.7) 48
7
/
8
(124.1) 49
7
/
8
(126.7) 30
1
/
8
(76.5) Min
19
INSTRUCTIONS D'INSTALLATION POUR FOUR ENCASTRÉ ÉLECTRIQUE
(Combiné à une table de cuisson électrique ou à gaz (en option))
Installateur
1. Lisez toutes les instructions contenues dans ce
feuillet avant l’installation du four encastré.
2. Enlevez tout le matériel d’emballage du four avant de
procéder au raccordement électrique.
3. Observez tous les codes et règlements applicables.
4. Assurez-vous de laisser ces instructions au
consommateur.
5. La porte du four peut être enlevée pour faciliter
l'installation.
6. CE FOUR N'EST PAS HOMOLOGUÉ POUR UNE
INSTALLATION CÔTE-À-CÔTE OU SUPERPOSÉE.
Consommateur
Conservez ces instructions avec votre Manuel
d'utilisation et d'entretien pour l'inspecteur d'électricité
local et références futures.
DIRECTIVES IMPORTANTES
DE SÉCURITÉ
• Assurez-vous que votre four encastré est installé et
mis à la terre conformément par un installateur ou un
technicien de service quali é.
• Ce four encastré doit être mis à la terre conformément
aux codes locaux d'électricité ou, en l'absence de
codes, en conformité avec le National Electrical Code
ANSI/NFA No. 70, dernière édition aux États-Unis, ou
avec la norme ACNOR C22.1, Partie 1, au Canada.
Grimper, s'appuyer ou s'asseoir sur la
porte de ce four encastré peut entraîner des blessures
graves et peut aussi causer des dommages au four
encastré.
• N’utilisez jamais votre four encastré pour chauffer
ou réchauffer la pièce. L’utilisation prolongée du
four encastré sans ventilation adéquate peut être
dangereuse.
Il faut couper l’alimentation électrique
durant le montage des connexions électriques. À défaut
de ce faire il peut en résulter des blessures graves ou la
mort.
1. Travaux de menuiserie
Reportez-vous à la gure 1 ou à la gure 2 pour
établir quelles sont les dimensions applicables à votre
modèle, ainsi que l'espace nécessaire pour recevoir
l'appareil. La surface qui supporte l'appareil doit être
en contre-plaqué solide ou tout autre matériau du
même type. Il faut vous assurer que la surface est de
niveau d'un côté à l'autre et de l'avant à l'arrière.
2. Réglage de la hauteur du four encastré
Lorsque requis, ce four peut être ajusté en hauteur avec
une entretoise en bois d’une largeur de 2" (5 cm) pour en
permettre l’installation dans le découpage existant d’une
armoire, si la hauteur du découpage excède la dimension
28
1
/
8
" (71.4 cm) pour un four encastré simple ou 49½"
(125.7 cm) pour un four encastré double (voir la gure 1
ou 2).
Placez l'entretoise de hauteur appropriée de chaque
côté de l'ouverture sous l'appareil.
3. Exigences électriques
Ces appareils doivent être branchés à une alimentation
possédant la tension et la fréquence appropriées. Ils
doivent être connectés à un circuit dédié correctement
mis à la terre et protégé par un disjoncteur ou un fusible.
Pour savoir quel disjoncteur ou fusible utiliser avec cet
appareil, référez-vous à la plaque signalétique pour
connaître la consommation (watts) et avec cette donnée,
consultez la table A pour connaître l'ampérage requis du
disjoncteur ou du fusible.
Table A
Observez tous les règlements et les codes locaux
applicables.
1. Un câble électrique à 3 ou 4 ls de 120/240 ou
120/208 Volt monophasé, 60 Hz CA est requis
sur un circuit séparé muni d’un fusible sur chaque
l conducteur (fusible temporisé ou disjoncteur
recommandé). NE RELIEZ PAS de fusible au neutre.
Il faut tenir compte de l'ajout d'une plaque de cuisson
superposée au four encastré. Référez-vous à la
plaque signalétique de chaque unité.
NOTE: Le calibre des ls et leurs connexions doivent
être conformes à la capacité des fusibles et à la capacité
nominale de l’appareil, selon le National Electrical
Code ANSI/NFPA No. 70, dernière édition, ou selon la
norme ACNOR C22,1, Partie 1, du Code canadien de
l’électricité et les codes et les règlements locaux.
N’utilisez pas de rallonge
électrique avec ces appareils. Son utilisation peut causer
un feu, un choc électrique ou des blessures corporelles.
Si un câble d'alimentation plus long est requis, vous
pouvez vous en procurer un de 10' (3 m) en téléphonant
au centre de service et en demandant le kit #903056-
9010.
2. Il faut brancher l’appareil au panneau de distribution
en utilisant des câbles exibles à gaine métallique
ou non métallique. On doit brancher directement à la
boîte de jonction le câble gainé exible de l’appareil.
Il faut disposer la boîte de jonction tel qu’illustré à
la Figure 1 ou 2 en laissant autant de lâche que
possible dans le câble entre la boîte et l’appareil,
pour en faciliter le déplacement si l’entretien s’avère
nécessaire.
3. Une attache de protection sécuritaire doit retenir le
câble armé exible à la boîte de jonction.
Calibre de
l'appareil
(Watts)
240V
Circuit de
protection
recommandé
Calibre de
l'appareil
(Watts)
208V
Circuit de
protection
recommandé
Moins de 4800W
20A
Moins de 4100W
20A
4801W - 7200W
30A
4101W - 6200W
30A
7201W - 9600W
40A ou 50A
6201W - 8300W
40A ou 50A
9601W et +
50A
8301W et +
50A
20
INSTRUCTIONS D'INSTALLATION POUR FOUR ENCASTRÉ ÉLECTRIQUE
(Combiné à une table de cuisson électrique ou à gaz (en option))
Par temps froid, pour protéger la
commande du four, il faut attendre au moins trois (3)
heures à la température de la pièce avant de mettre
l'appareil sous tension. Ceci évitera toute possibilité
d'endommager la commande du four lors de la mise sous
tension.
4. Connexions électriques
Le consommateur est responsable et doit communiquer
avec un installateur quali é pour s'assurer que
l'installation électrique est adéquate et conforme avec
le National Electrical Code ANSI/NFPA No. 70-dernière
édition, ou avec la norme ACNOR C22.1, partie 1, du
code canadien de l'électricité, et les codes et règlements
locaux.
Risque de choc électrique (Si cet
avertissement n'est pas pris en considération, un choc
électrique ou des blessures sérieuses peuvent survenir).
Cet appareil est muni de ls en cuivre. Si ce dernier
est branché à circuit résidentiel en aluminium, n'utilisez
que des connecteurs qui sont approuvés pour joindre
des ls de cuivre à des ls d'aluminium conformément
au National Electrical Code et les codes et règlements
locaux. Lors de l’installation des connecteurs munis de
vis touchant directement l’acier ou l’aluminium de conduit
exible, il ne faut pas serrer celles-ci outre mesure a n
d’éviter d’endommager le conduit exible. Il ne faut ni
plier ni tordre outre mesure un conduit exible de manière
à éviter un bris dans la gaine et une exposition des ls ou
câbles internes.
NE connectez pas le l de mise à la terre à un tuyau
d’alimentation de gaz. Ne branchez pas l’appareil
au circuit électrique avant qu’il soit mis à la terre
correctement, en permanence. Branchez le conducteur de
mise à la terre avant de mettre l’appareil sous tension.
Figure 3
BOÎTE DE JONCTION À 3 FILS MISE À LA TERRE
Câble d'alimentation
Fils
noirs
Connecteur
homologué- U.L.
(ou ACNOR)
Câble de l'appareil
Fil dénudé
ou vert
Fil dénudé
Fil blanc
Fils rouges
Boîte de
jonction
Risque de choc électrique
• La mise à la terre de cet appareil est obligatoire.
• Ne branchez pas l’appareil au circuit électrique
tant qu’il ne sera pas mis à la terre correctement
et en permanence.
• Coupez l’alimentation à la boîte de jonction avant
de faire les raccords électriques.
• Cet appareil doit être connecté à un circuit
permanent électrique, métallique et mis à la terre,
ou à un connecteur de mise à la terre qui doit être
branché à la borne ou au l de mise à la terre de
l’appareil.
• N’utilisez pas un tuyau d’alimentation de gaz pour
la mise à la terre de l’appareil.
Si vous ne respectez pas toutes les instructions
précédentes, un feu, des blessures corporelles ou
un choc électrique peuvent en résulter.
(Si votre appareil possède un câble
muni d'un conducteur blanc neutre.)
Cet appareil est fabriqué avec un câble d’alimentation
muni d’un l blanc neutre et d’un l de mise à la terre
en cuivre branché sur le châssis. Si l'appareil est utilisé,
aux États-Unis, dans une maison mobile, un nouveau
branchement (1996 NEC), un véhicule récréatif où les
codes locaux n'autorisent pas la connexion du conducteur
de mise à la terre du châssis au neutre ou au Canada,
débranchez les ls blanc et vert des autres et utilisez
le l de mise à la terre pour mettre à la terre l'appareil
conformément aux codes locaux, branchez le conducteur
neutre de manière habituelle au circuit neutre voir la
gure 4. Si l'appareil doit être branché à un câble à 3
ls (aux États-Unis seulement), où les codes locaux
permettent la connexion du l de mise à la terre du
châssis au neutre (blanc). Voir la gure 3.
ÉLECTRICIEN: Le câble gainé fourni avec cet
appareil est homologué par UL pour connexion à des
circuits résidentiels de ls de calibre supérieur. La
capacité thermique de l'isolant des câbles excède
considérablement celle des circuits résidentiels. La
transmission du courant électrique maximum permise des
ls du câble est en fonction de la capacité thermique de la
gaine plutôt que du calibre du l.
Si les codes locaux permettent la connexion du l de mise
à la terre du châssis au neutre (blanc) (aux États-Unis
seulement) (voir gure 3):
1.
Coupez l’alimentation à la boîte de jonction.
2. Dans la boîte de jonction:
Raccordez les ls de l'appareil à ceux du circuit
électrique tel que montré à la gure 3.
21
INSTRUCTIONS D'INSTALLATION POUR FOUR ENCASTRÉ ÉLECTRIQUE
(Combiné à une table de cuisson électrique ou à gaz (en option))
Emplacement de la
plaque signalétique des
fours encastrés simples
Emplacement de la plaque
signalétique des fours
encastrés doubles
Figure 4 - BOÎTE DE JONCTION À 4 FILS
MISE À LA TERRE
Câble d'alimentation
Fil blanc
Boîte de
jonction
Câble de l'appareil
Fil dénudé
ou vert
Fil dénudé
Fil blanc
Fils
noirs
Fils
rouges
Connecteur
homologué- U.L.
(ou ACNOR)
Si l’appareil est utilisé dans une maison mobile, un
nouveau branchement (1996 NEC), un véhicule récréatif
ou si les codes locaux N'AUTORISENT PAS la connexion
du conducteur de mise à la terre du châssis au neutre, le
châssis de l'appareil NE DOIT PAS être branché au l neutre
du câble à 4 ls (voir le gure 4):
1.
Coupez l’alimentation à la boîte de jonction.
2. Séparez le l blanc du l dénudé en cuivre de mise à
la terre du câble d’alimentation de l’appareil.
3. Dans la boîte de jonction:
Raccordez les ls de l'appareil à ceux du circuit
électrique tel que montré à la gure 4.
Emplacement des numéros de modèle et de série
La plaque signalétique est située sur le côté intérieur
de la moulure latérale.
Pour toute commande de pièces ou demande de
renseignement au sujet de votre appareil, assurez-
vous d'inclure les numéros de modèle et de série, ainsi
que le numéro ou lettre de lot de la plaque signalétique
de votre four.
Risque de lourde charge
Soyez 2 personnes ou plus pour installer ou déplacer
l'appareil.
Des blessures ou des dommages à l'appareil peuvent
survenir si vous ne suivez pas cette instruction.
5. Installation dans l'armoire
IMPORTANT
Ne soulevez pas l'appareil par la poignée de la porte.
1 Déballez le four encastré et récupérez la moulure
inférieure qui est xée sur le côté du four
2 Localisez les vis de xation qui se trouvent dans
l'enveloppe littérature.
3 Insérez l’appareil dans le découpage de l’armoire.
Glissez l’unité vers l’intérieur en laissant un espace
de 1½" (3.8 cm) entre le four et le devant de
l’armoire (voir gure 5).
4 Tout en glissant l’appareil dans l'armoire, tirez
le câble gainé à travers le trou du plancher de
l’armoire et vers la boîte de jonction.
5 Poussez l'appareil complètement dans l'armoire.
Figure 5
Espace d'environ
1½" (3.8 cm)
22
INSTRUCTIONS D'INSTALLATION POUR FOUR ENCASTRÉ ÉLECTRIQUE
(Combiné à une table de cuisson électrique ou à gaz (en option))
Figure 7
Moulure
inférieure
Vis
fournies
6 Installez les vis de xation
Le four encastré peut basculer
quand la porte est ouverte. Il faut xer l'appareil à
l'armoire, à l'aide des vis de xation fournis, pour
prévenir le renversement du four et des blessures
corporelles.
A. Les trous situés sur les moulures latérales
peuvent servir de gabarit (voir la gure 6).
B. Utilisez les deux vis fournies pour xer
l'appareil à l'armoire.
Trous des vis de xation
Figure 6
7 Installation de la moulure inférieure:
Placez le haut de la moulure inférieure par dessus
les petites languettes de chaque côté du four
encastré, sous la porte. Vissez la moulure dans
les trous situés de chaque côté de l'appareil en
utilisant les vis fournies avec la moulure (voir la
gure 7).
IMPORTANT : la garniture inférieure doit
être installée pour que le four fonctionne
adéquatement. N'utilisez PAS le four sans avoir
installé la garniture inférieure.
Risque de basculement
Trous de montage du
dispositif anti-renverse-
ment
Pour une installation adéquate
du dispositif anti-renverse-
ment, reportez-vous aux
instructions d'installation
fournies avec votre cuisinière.
Effectuez une vérification
visuelle de la présence des vis
du dispositif anti-renversement
pour vous assurer qu'il a été
installé correctement.
Vérifiez l'installation du dispositif en ouvrant la porte du
four et en appliquant sur cette dernière une légère
pression vers le bas. La cuisinière ne devrait pas
basculer vers l'avant.
• Un enfant ou un adulte peut faire
basculer la cuisinière et en
décéder.
• Installez le dispositif
anti-renversement sur la
cuisinière et/ou la structure selon
les instructions d'installation.
Assurez-vous d'enclencher de nouveau le dispositif
anti-renversement lorsque la cuisinière est déplacée.
• Ne faites pas fonctionner la cuisinière si le
dispositif anti-renversement n'est pas en place et
enclenché.
• Le non-respect de ces instructions peut causer des
blessures fatales ou de graves brûlures aux enfants
et aux adultes.
23
INSTRUCTIONS D'INSTALLATION POUR FOUR ENCASTRÉ ÉLECTRIQUE
(Combiné à une table de cuisson électrique ou à gaz (en option))
Seulement certains modèles de tables de cuisson peuvent
être installés au-dessus de certains modèles de fours
encastrés. Les modèles approuvés pour être combinés
sont identi és à l'aide d'un numéro MGF ID et d'un
code de produit (Consultez la feuille qui se trouve dans
l'enveloppe de littérature ainsi que le feuillet d'instructions
d'installation de la table de cuisson pour les dimensions).
G
F
H
36” Min.
(91.4 cm) Min.
208/240 Volt, boîte de jonction
pour le four encastré
Figure 8 - INSTALLATION TYPIQUE D'UN FOUR ENCASTRÉ SIMPLE SOUS LE COMPTOIR
AVEC UNE TABLE DE CUISSON ÉLECTRIQUE OU À GAZ INSTALLÉE PAR-DESSUS
Approx. 3”
(7.5 cm)
4½” (11.5 cm) Max.
DIMENSIONS DE L'OUVERTURE
F. LARGEUR G. PROFONDEUR
H. HAUTEUR
Four encastré
27" (68.6 cm)
Four encastré
30" (76.2 cm)
24
7
/
8
" (63.2 cm) Min.
25¼" (64.1 cm) Max.
28½" (72.4 cm) Min.
29" (73.7 cm) Max.
23½" (59.7 cm) Min.
23½" (59.7 cm) Min.
27¼" (69.2 cm) Min.
28
5
/
8
" (72.7 cm) Max.
27¼" (69.2 cm) Min.
28
5
/
8
" (72.7 cm) Max.
Pour réduire les
risques de blessures et
pour empêcher le four
encastré de basculer.
Utilisez les supports
de xation pour retenir
le four encastré à
l'armoire.
Utilisez un contre-plaqué de ¾"
(1.9 cm) d'épaisseur monté sur deux
solives et à égalité avec le coup-de-
pied. La base doit pouvoir supporter
150 lbs (68 kg) pour les modèles 27" et
200 lbs (90 kg) pour les modèles 30".
Découpez une ouverture de 9" X 9" (23 cm X
23 cm), à 2" (5 cm) du côté gauche du plancher
pour la sortie du câble armé de l'appareil vers la
boîte de jonction.
Il faut fermer les côtés de l'habitacle
par des panneaux de bois pour isoler
l'appareil des armoires de chaque côté.
La hauteur de ces panneaux doit faire
en sorte que l'installation des modèles
de tables de cuisson au dessus soit
possible.
L'installation typique d'un four encastré électrique sous le comptoir est présentée à la gure 8.
24
INSTRUCTIONS D'INSTALLATION POUR FOUR ENCASTRÉ ÉLECTRIQUE
(Combiné à une table de cuisson électrique ou à gaz (en option))
Figure 9 - INSTALLATION TYPIQUE D'UNE TABLE DE CUISSON À GAZ MONTÉE AU DESSUS
D'UN FOUR ENCASTRÉ ÉLECTRIQUE MONTÉ SOUS LE COMPTOIR
18”(45.7 cm) Max.
6 1/2” Min.
(16.5 cm)
Raccord
évasé
4”(10 cm)
Prise
120V/60Hz
mise à la terre
Côté droit de
l'armoire
(Accès facile
pour fermer
la robinet)
Régulateur
de pression
Robinet de
fermeture
manuel
Conduit à gaz exible
Côtés de l'armoire
ou panneau de
fermeture
Armoire où le four est installé
5” Max.
(12.7 cm)
Raccord
évasé
TABLE DE CUISSON À GAZ
6. Mise à niveau du four encastré
1. Installez une grille au centre du four supérieur.
2. Déposez un niveau à bulle sur la grille (voir la gure
10). Prenez 2 lectures en plaçant le niveau en diago-
nale dans une direction, puis dans l’autre direction.
Utilisez des entretoises de bois sous le four encastré
pour niveler si nécessaire.
3. Si vous avez un four encastré double, répétez les
mêmes étapes dans le four inférieur. Si le niveau à
bulle indique que la grille n'est pas à niveau, utilisez
des entretoises de bois pour trouver un ajustement
adéquat pour les deux fours.
Figure 10
NOTE IMPORTANTE
Une souf erie située dans la partie interne
supérieure à l'arrière de l'appareil permet de garder
les composantes électriques et électroniques
internes froides. Il est donc possible que la
souf erie continue de fonctionner même après
l’arrêt de l’appareil, et ce, jusqu’à ce que les
composantes aient refroidi.
7. Véri cation du fonctionnement
Si votre appareil possède une commande électronique
de four. Toutes les fonctions qu'elle contrôle ont été
véri ées en usine pour leur bon fonctionnement avant que
l'appareil soit expédié. Cependant, nous vous suggérons
de véri er à nouveau le fonctionnement de la commande
électrique. Reportez-vous à votre Manuel d'utilisation et
d'entretien pour le réglage du four.
1. Retirer tous les items du four avant de procéder à la
véri cation.
2. Mettre l'appareil sous tension.
3.Véri er les opérations de la commande électronique:
Cuisson–Véri er que lorsque le four est en fonction
cuisson, l'élément de cuisson chauffe. 20 secondes après
avoir programmé le four en mode cuisson, si en ouvrant
la porte vous sentez de la chaleur s'échapper du four,
c'est qu'il fonctionne.
Grillage–L'élément du haut rougit lorsque le four est réglé
pour le mode grillage.
Convection–Si le four est réglé pour la cuisson ou le
rôtissage par convection, les deux éléments cyclent
et le ventilateur convection situé à l'arrière tourne. Le
ventilateur convection arrête lorsque l'on ouvre la porte du
four.
Avant d'appeler le service d'entretien
Réviser la liste de véri cations préventives et les
instructions d'opération dans votre Manuel d'utilisation
et d'entretien. Vous sauverez probablement du temps
et de l'argent. La liste contient les incidents ordinaires
ne résultant pas de défectuosités dans le matériel ou la
fabrication de cet appareil.
Pour obtenir notre adresse et notre numéro de téléphone
sans frais, référez-vous à votre Manuel d'utilisation et
d'entretien.

Transcripción de documentos

ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS (and Optional Electric or Gas Cooktop Combination) INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. United States and Canada FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Your new wall oven has been designed to fit a limited variety of cutout sizes to make the job of installing easier. The first step of your installation should be to measure your current cutout dimensions and compare them to the cutout dimensions chart below for your model. You may find little or no cabinet work being necessary. Do not remove spacers (if equipped) on the side walls of the built-in oven. These spacers center the oven in the space provided. The oven must be centered to prevent excess heat buildup that may result in heat damage or fire. NOTES: I 1. Base must be capable of supporting 150 pounds (68 kg) for 27" 1½” (3.8 cm) models and 200 pounds (90 kg) for 30" models. Min. 2. Allow at least 21" (53.3 cm) clearance in front of oven for door depth when it is open. 3. Dimension G (cutout depth) is critical to C Hole for G the proper installation of the built-in oven. Cord F If the oven decorative trim does not butt H B against the cabinet, or if noise is heard 27 1/4” (69.2 cm) 3” on convection models, verify dimension (7.6 cm) G to assure it is the required depth. 4. For a cutout height greater than 281/8" 31”* (78.7 cm) (71.4 cm) add one 2"(5 cm) Door Open Spacer wide wood shim of appropriate D (see note 2) 2” height to each side of the (5.1 cm) opening under the appliance A Min. side rails. Electrical 5. 30" MODELS ONLY: For a Junction Box 2" (5 cm) Wide Wood cutout height (H) greater than Spacer if Needed 5 28 /8" (72.7 cm) you can order a larger bottom trim through a * Suggested distance from floor is 31" (78.7cm). Service Center. Minimum required distance is 4 ½" (11.4cm). Figure 1 27" and 30" Single Wall Ovens (Double ovens see Figure 2) PRODUCT DIMENSIONS MODEL A B C D 27" (68.6 cm) Wall Oven 27 (68.6) 29 (73.7) 24 /8 (62.5) 24¾ (62.9) 30" (76.2 cm) Wall Oven 30 (76.2) 29 (73.7) 28¼ (71.8) 24¾ (62.9) 5 CUTOUT DIMENSIONS AND CABINET WIDTH F G (Min.) MODEL Min. Max. 27" (68.6 cm) Wall Oven 24 /8 (63.2) 25¼ (64.1) 30" (76.2 cm) Wall Oven 28½ (72.4) 29 (73.7) 7 H. Standard Height (**Others, see notes 4 & 5) I Min. Max. 23½ (59.7) 27¼ (69.2) 28 /8 (72.7) 271/8 (68.9) Min 23½ (59.7) 27¼ (69.2) 285/8 (72.7) 301/8 (76.5) Min 5 PN 807153701 Rev. A (1212) All dimensions are in inches (cm). Printed in U.S.A. 1 English – pages 1-8 Español – páginas 9-16 Français -pages 17-24 ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS (and Optional Electric or Gas Cooktop Combination) Do not remove spacers (if equipped) on the side walls of the built-in oven. These spacers center the oven in the space provided. The oven must be centered to prevent excess heat buildup that may result in heat damage or fire. I 1½” (3.8 cm) Min. C G F Hole for Cable H 48 5/8” (123.5 cm) B 3” (7.6 cm) Max. 11½” (29.2 cm) Door Open (see note 2) 2” (5.1 cm) Min. Spacer D 2" (5 cm) Wide Wood Spacer if Needed A Electrical Junction Box NOTES: 1. Base must be capable of supporting 300 pounds 4. For a cutout height greater than 49½" (125.7 cm) (136 kg) for 27" models and 375 pounds (170 kg) add a 2" (5 cm) wide wood shim of appropriate for 30" models. height to each side of the opening under the 2. Allow at least 21" (53.3 cm) clearance in front of appliance side rails. oven for door depth when it is open. 5. 30" MODELS ONLY: For a cutout height (H) 3. Dimension G (cutout depth) is critical to the greater than 497/8" (126.7 cm) you can order a proper installation of the built-in oven. If the oven larger bottom trim through a Service Center. decorative trim does not butt against the cabinet, or if noise is heard on convection models, verify dimension G to assure it is according to the required dimension. Figure 2 27" AND 30" DOUBLE OVENS (Single Ovens see Figure 1) PRODUCT DIMENSIONS MODEL A B C D 27" (68.6 cm) Wall Oven 27 (68.6) 507/16 (128.1) 245/8 (62.5) 24¾ (62.9) 30" (76.2 cm) Wall Oven 30 (76.2) 50 /16 (128.1) 28¼ (71.8) 24¾ (62.9) 7 CUTOUT DIMENSIONS AND CABINET WIDTH F G (Min.) MODEL Min. Max. 27" (68.6 cm) Wall Oven 247/8 (63.2) 25¼ (64.1) 30" (76.2 cm) Wall Oven 28½ (72.4) 29 (73.7) H. Standard Height (**Others, see notes 4 & 5) I Min. Max. 23½ (59.7) 487/8 (124.1) 497/8 (126.7) 271/8 (68.9) Min 23½ (59.7) 48 /8 (124.1) 49 /8 (126.7) 301/8 (76.5) Min All dimensions are in inches (cm). 2 7 7 ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS (and Optional Electric or Gas Cooktop Combination) 3. Electrical Requirements Important Notes to the Installer 1. Read all instructions contained in these installation instructions before installing the wall oven. 2. Remove all packing material from the oven compartments before connecting the electrical supply to the wall oven. 3. Observe all governing codes and ordinances. 4. Be sure to leave these instructions with the consumer. 5. Oven door may be removed to facilitate installation. 6. THESE OVENS ARE NOT APPROVED FOR STACKABLE OR SIDE-BY-SIDE INSTALLATION. This appliance must be supplied with the proper voltage and frequency, and connected to an individual, properly grounded branch circuit, protected by a circuit breaker or fuse. To know the circuit breaker or fuse required by your model, see the serial plate to find the wattage consumption and refer to table A to get the circuit breaker or fuse amperage. Important Note to the Consumer Keep these instructions with your Owner's Guide for the local electrical inspector's use and future reference. IMPORTANT SAFETY INSTRUCTIONS • Be sure your wall oven is installed and grounded Appliance Rating Watts 240V Protection Circuit Recommended Appliance Rating Watts 208V Protection Circuit Recommended Less than 4800W 20A Less than 4100W 20A 4801W - 7200W 30A 4101W - 6200W 30A 7201W - 9600W 40A or 50A 6201W - 8300W 40A or 50A 9601W and + 50A 8301W and + 50A Table A Observe all governing codes and local ordinances 1. A 3-wire or 4-wire single phase 120/240 or 120/208 Volt, 60 Hz AC only electrical supply is required on a separate circuit fused on both sides of the line (red and black wires). A time-delay fuse or circuit breaker is recommended. DO NOT fuse neutral (white wire). Only certain cooktop models may be installed over certain built-in electric oven models. Approved cooktops and built-in ovens are listed by the MFG ID number (see the insert sheet included in the literature package). properly by a qualified installer or service technician. • This wall oven must be electrically grounded in accordance with local codes or, in their absence, with the National Electrical Code ANSI/NFPA No.70latest edition in United Sates, or with CSA Standard C22.1, Canadian Electrical Code, Part 1, in Canada. Stepping, leaning or sitting on the door of this wall oven can result in serious injuries and can also cause damage to the wall oven. NOTE: Wire sizes and connections must conform with the fuse size and rating of the appliance in accordance with the American National Electrical Code ANSI/NFPA No. 70-latest edition, or with Canadian CSA Standard C22.1, Canadian Electrical Code, Part 1, and local codes and ordinances. • Never use your wall oven for warming or heating the room. Prolonged use of the wall oven without adequate ventilation can be dangerous. The electrical power to the oven must be shut off while line connections are being made. Failure to do so could result in serious injury or death. An extension cord should not be used with this appliance. Such use may result in a fire, electrical shock, or other personal injury. If you need a longer power cord you can purchase a 10' (3 m) power cord kit #903056-9010 by calling the Service Center. 1. Carpentry Refer to figure 1 or 2 for the dimensions applicable to your appliance, and the space necessary to receive the oven. The oven support surface may be solid plywood or similar material, however the surface must be level from side to side and from front to rear. 2. These appliances should be connected to the fused disconnect (or circuit breaker) box through flexible armored or nonmetallic sheathed cable. The flexible armored cable extending from the appliance should be connected directly to the junction box. The junction box should be located as shown in Figure 1 or Figure 2 and with as much slack as possible remaining in the cable between the box and the appliance, so it can be moved if servicing is ever necessary. 3. A suitable strain relief must be provided to attach the flexible armored cable to the junction box. 2. Adjusting Oven Height Oven height can be adjusted with 2" (5cm) wide wood shims when needed to fit into an existing cabinet cutout opening, when cutout height exceeds 281/8" (71.4cm) for the single wall oven or 49½" (125.7cm) for the double wall oven (see Figure 1 or 2). Place shims of appropriate height beneath the oven side rails. 3 ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS (and Optional Electric or Gas Cooktop Combination) (If your appliance is equipped with a white neutral conductor.) This appliance is manufactured with a white neutral power supply and a frame connected copper wire. The frame is grounded by connection of grounding lead to neutral lead at the termination of the conduit, if used in USA, in a new branch circuit installation (1996 NEC), mobile home, recreational vehicles, where local code do not permit grounding trough the neutral (white) wire or in Canada, disconnect the white and green lead from each other and use ground lead to ground unit in accordance with local codes, connect neutral lead to branch circuit-neutral conductor in usual manner see Figure 4. If your appliance is to be connected to a 3 wire grounded junction box (US only), where local code permit connecting the appliance-grounding conductor to the neutral (white) see Figure 3. Electrical Shock Hazard • Electrical ground is required on this appliance. • Do not connect to the electrical supply until appliance is permanently grounded. • Disconnect power to the junction box before making the electrical connection. • This appliance must be connected to a grounded, metallic, permanent wiring system, or a grounding connector should be connected to the grounding terminal or wire lead on the appliance. • Do not use a gas supply line for grounding the appliance. Failure to do any of the above could result in a fire, personal injury or electrical shock. NOTE TO ELECTRICIAN: The armored cable leads supplied with the appliance are UL-recognized for connection to larger gauge household wiring. The insulation of the leads is rated at temperatures much higher than temperature rating of household wiring. The current carrying capacity of the conductor is governed by the temperature rating of the insulation around the wire, rather than the wire gauge alone. In cold weather shipping and storage conditions, make sure that oven is in final location at least three (3) hours before switching on power. Switching on power while oven is still cold may damage the oven controls. 4. Electrical connection It is the responsibility and obligation of the consumer to contact a qualified installer to assure that the electrical installation is adequate and is in conformance with the National Electrical Code ANSI/NFPA No. 70-latest edition, or with CSA Standard C22.1, Canadian Electrical Code, Part 1, and local codes and ordinances. Where local codes permit connecting the appliancegrounding conductor to the neutral (white) wire (US Only) (see figure 3): 1. Disconnect the power supply. 2. In the junction box: connect appliance and power supply cable wires as shown in Figure 3. Risk of electrical shock (Failure to heed this warning may result in electrocution or other serious injury.) This appliance is equipped with copper lead wire. If connection is made to aluminum house wiring, use only connectors that are approved for joining copper and aluminum wire in accordance with the National Electrical Code and local code and ordinances. When installing connectors having screws which bear directly on the steel and/or aluminum flexible conduit, do no tighten screws sufficiently to damage the flexible conduit. Do not over bend or excessively distort flexible conduit to avoid separation of convolutions en exposure of internal wires. Cable from Power Supply White Wire (Neutral) Black Wires Red Wires Junction Box DO NOT ground to a gas supply pipe. DO NOT connect to electrical power supply until appliance is permanently grounded. Connect the ground wire before turning on the power. Ground Wire (Bare or Green Wire) White Wire (Neutral) U.L.-Listed Conduit Connector (or CSA listed) Cable from appliance Figure 3 3-WIRE GROUNDED JUNCTION BOX 4 ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS (and Optional Electric or Gas Cooktop Combination) 5. Cabinet Installation If oven is used in a new branch circuit installation (1996 NEC), mobile home, recreational vehicle, or where local codes DO NOT permit grounding through the neutral (white) wire, the appliance frame MUST NOT be connected to the neutral wire of the 4-wire electrical system. (see figure 4): 1. Disconnect the power supply. 2. Separate the green (or bare copper) and white appliance cable wires. 3. In the junction box: connect appliance and power supply cable wires as shown in Figure 4. IMPORTANT Do not lift the oven by the door handle. Heavy Weight Hazard • Use 2 or more people to move and install wall oven. • Failure to follow this instruction can result in injury or damage to the unit. 1 Unpack the wall oven. Remove the bottom trim taped on the oven side panel. 2 Find the 2 anti-tip mounting screws included in the literature package. 3 Insert the oven into the cabinet opening. Slide oven inward leaving 1½" (3.8 cm) clearance between the oven and front of cabinet (see Figure 5). 4 Pull the armored cable through the hole for it in the cabinet and toward the junction box while moving the appliance inward. 5 Push the oven in and against the cabinet. Cable from Power Supply Ground Wire White Wire Red Wires Black Wires Ground Wire (Bare or Green Wire) Junction Box White Wire U.L.-Listed Conduit Connector (or CSA listed) Cable from appliance Figure 4 4-WIRE GROUNDED JUNCTION BOX Model and Serial Number Location The serial plate is located along the interior side trim of the oven and visible when the door is opened. When ordering parts for or making inquires about your oven, always be sure to include the model and serial numbers and a lot number or letter from the serial plate on your oven. 1½" (3.8 cm) clearance between unit Single Wall Oven Serial Plate Location Figure 5 Double Wall Oven Serial Plate Location 5 ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS (and Optional Electric or Gas Cooktop Combination) 7 Install the Bottom Trim 6 Install the Anti-tip Mounting Screws The wall oven can tip when the door is open. The anti-tip mounting screws supplied with the wall oven must be installed to prevent tipping of the wall oven and injury to persons. IMPORTANT: Bottom trim must be installed for the oven to function properly. DO NOT operate the oven without the bottom oven trim installed. A. The mounting holes in the side trims may be used as a template to locate the appliance mounting screw holes (see figure 6). B. Use the two screws supplied to fix the appliance to the cabinet. Place the top of the bottom trim over the side trim tabs on each side of the oven below the oven door and fix it using the 2 screws supplied in the mounting holes located on each side trim below the oven frame (see Figure 7). Anti-Tip Mounting Holes Figure 6 Tip Over Hazard Screws supplied • A child or adult can tip the oven and be killed. • Install the anti-tip device to oven and/or structure per installation instructions. • Ensure the anti-tip device is re-engaged when the oven is moved. • Do not operate the oven without the anti-tip device in place and engaged. • Failure to follow these instructions can result in death or serious burns to children and adults. Bottom Trim Figure 7 Refer to the installation instructions supplied with your appliance for proper installation. Check for proper installation with a visual check that the anti-tip screws are present. Test the installation with light Anti-tip mounting holes downward pressure on the open oven door. The oven should not tip forward. 6 ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS (and Optional Electric or Gas Cooktop Combination) For typical under counter installation of an electric built-in oven see Figure below. Cabinet side filler panels are necessary to isolate the unit from adjoining cabinets. Cabinet side filler height should allow for installation of approved cooktop models Only certain cooktop models may be installed over certain built-in electric oven models. Approved cooktops and built-in ovens are listed by the MFG ID number and product code (see the insert sheet included in the literature package and cooktop installation instructions for dimensions). Approx. 3” (7.5 cm) To reduce the risk of personal injury and tipping of the wall oven, the wall oven must be secured to the cabinet (s) by mounting screws. 36” Min. (91.4 cm) Min. G H 208/240 Volt junction box for built-in oven. F Use 3/4” (1.9 cm) plywood, installed on two runners, flush with toe plate. Base must be capable of supporting 150 pounds (68 kg) for 27" models and 200 pounds (90 kg) for 30" models. Cut an opening in wood base minimum 9” x 9” (23 X 23 cm), 2” (5 cm) from left side filler panel, to route armored cable to junction box. 4 1/2” (11.5 cm) Max.* CUTOUT DIMENSIONS * If no cooktop is installed directly over the oven unit, 5” (12.7 cm) maximum is allowed above the floor. F.WIDTH G.DEPTH H.HEIGHT 27" (68.6 cm) Wall Oven 247/8" (63.2 cm) Min. 25¼" (64.1 cm) Max. 23½" (59.7 cm) Min. 27¼" (69.2 cm) Min. 285/8" (72.7 cm) Max. 30" (76.2 cm) Wall Oven 28½" (72.4 cm) Min. 29" (73.7 cm) Max. 23½" (59.7 cm) Min. 27¼" (69.2 cm) Min. 285/8" (72.7 cm) Max. Figure 8- TYPICAL UNDER COUNTER INSTALLATION OF A SINGLE ELECTRIC BUILT-IN OVEN WITH AN ELECTRIC COOKTOP MOUNTED ABOVE 7 ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS (and Optional Electric or Gas Cooktop Combination) 18”(45.7 cm) Max. 4”(10 cm) 5” Max. 6 1/2” Min. (12.7 cm) (16.5 cm) Flare Union Flexible Appliance Conduit Flare Union Cabinet sides or filler panel 120V/60Hz Grounded Outlet Pressure Regulator Right Side of Cabinet (To be accessible for shut-off valve operation) Manual Shutoff Valve Wall Oven Cabinet Figure 9 - TYPICAL UNDER COUNTER INSTALLATION OF A SINGLE ELECTRIC BUILT-IN OVEN WITH A GAS COOKTOP ABOVE 6. Leveling the Wall Oven 7. Checking Operation 1. Install an oven rack in the center of the upper oven (see Figure 10). 2. Place a level on the rack. Take 2 readings with the level placed diagonally in one direction and then the other. Use wood shims under the wall oven to level if necessary. 3. Repeat in the lower oven if you have a double cavity wall oven. If the level indicates that the rack is not level, use wood shims to reach a compromise for both ovens. Your model is equipped with an Electronic Oven Control. Each of the functions has been factory checked before shipping. However, it is suggested that you verify the operation of the electronic oven controls once more. Refer to the Use and Care Guide for operation. 1. Remove all items from the inside of the oven. 2. Turn on the power to the oven (Refer to your Use & Care Guide.) 3. Verify the operation of the electronic oven controls: Bake– Verify that this function makes the oven hot. 20 seconds after turning oven on, open the door and you should feel heat coming from the oven. Broil– When the oven is set to BROIL, the upper element in the oven should become red. Figure 10 Convection (some models)–When the oven is set for a convection baking or roasting, both elements cycle on and off alternately and the convection fan will run. The convection fan will stop running when the oven door is opened. IMPORTANT NOTE A cooling fan inside the upper rear part above the oven (some models) provides cooling of the oven electrical and electronic components. If the oven has been operating at high temperatures, the fan will continue to run after the oven is turned off. Before You Call for Service Read the "Before You Call for Service Checklist" and the "Operating Instructions" in your Use and Care Guide. It may save you time and expense. The list includes common occurrences that are not the result of defective workmanship or materials in this appliance. Refer to your Use and Care Guide for service phone numbers. 8 INSTRUCCIONES DE INSTALACIÓN PARA EL HORNO ELÉCTRICO DE PARED (Combinado con una cocina eléctrica o de gas facultativa) LA INSTALACIÓN Y EL SERVICIO DEBEN SER EFECTUADOS POR UN INSTALADOR CALIFICADO. IMPORTANTE: GUARDE ESTAS INSTRUCCIONES PARA USO DEL INSPECTOR LOCAL DE ELECTRICIDAD. LEA Y GUARDE ESTAS INSTRUCCIONES PARA REFERENCIA FUTURA. PARA SU SEGURIDAD: No almanece ni utilice gasolina u otros vapores y líquidos inflamables en la proximidad de este o de cualquier otro artefacto. Estados Unidos y Canadá El primer paso para su instalación debe de ser el de medir las dimensiones de la apertura y compararlas con las que se indican en el cuadro de dimensiones del hueco de la figura 1. Posiblemente encontrará que algún trabajo de carpintería será necesario. No quite los separadores de los muros laterales del horno empotrado. Estos espaciadores centran el horno en el espacio provisto. El horno debe estar centrado para prevenir una concentración excesiva de calor que podría resultar en daños por el calor o un incendio. NOTAS: 1. La base debe poder sostener 150 libras (68 kg) para los modelos 27" y la I base debe poder sostener 200 libras (90 kg) para los modelos 30". 1½” (3.8 cm) 2. Deje por lo menos 21" (53.3 cm) de espacio libre para la Min. profundidad de la puerta cuando esta abierta. 3. La dimensión G (profundidad del C Orificio corte) está primordial para instalar G para el correctamente el horno de pared. Si el F H Cable adorno del armazón del horno no topa 27 1/4” contra el armario, o si escuche un ruido, B (69.2 cm) 3” verifique si la dimensión G está en (7.6 cm) conformidad con la dimensión requerida. 4. Para un corte de una altura mayor que 31”* 281/8" (71,4 cm) agregar una (78.7 cm) cuña de madera de 2" (5 cm) Puerta Abierta Espaciador de ancho para lograr la altura D (vea la nota 2) 2” apropiada a cada lado del (5.1 cm) orificio ubicado debajo de los Caja A Min. rieles laterales del accesorio. eléctrica de empalme 5. MODELOS 30" SOLAMENTE: Para un corte de una Espaciador de Madera de 2" altura (H) mayor que 285/8" (72.7 cm) puede solicitar (5 cm) de ancho, si es necesario un ajuste inferior más grande a través de un Centro de Servicio. * Distancia sugerida desde el suelo es 31" (78.7 cm). La distancia mínima requerida es 4½" (11.4 cm). Figura 1 Hornos simples de Pared de 27" y 30" (Para hornos dobles, ver la Figura 2) DIMENSIONES DEL APARATO MODELO A B C D Horno de pared 27" (68.6cm) 27 (68.6) 29 (73.7) 245/8 (62.5) 24¾ (62.2) Horno de pared 30" (76.2cm) 30 (76.2) 29 (73.7) 28¼ (71.8) 24¾ (62.2) DIMENSIONES DEL HUECO Y ANCHURA DEL ARMARIO F G (Mín.) MODELO Mín. Máx. Horno de pared 27" (68.6cm) 247/8 (63.2) 25¼ (64.1) Horno de pared 30" (76.2cm) 28½ (72.4) 29 (73.7) H. Altura estándar (**Otras, vea notas 4 & 5) I Mín. Máx. 23½ (59.7) 27¼ (69.2) 285/8 (72.7) 271/8 (68.9) Mín 23½ (59.7) 27¼ (69.2) 28 /8 (72.7) 301/8 (76.5) Mín 5 Todas las dimensiones se dan en pulgadas (cm). P/N 807153701 (1212) Rev. A Imprimido en U.S.A. 9 English – pages 1-8 Español – páginas 9-16 Français - pages 17-24 INSTRUCCIONES DE INSTALACIÓN PARA EL HORNO ELÉCTRICO DE PARED (Combinado con una cocina eléctrica o de gas facultativa) No quite los separadores de los muros laterales del horno empotrado. Estos espaciadores centran el horno en el espacio provisto. El horno debe estar centrado para prevenir una concentración excesiva de calor que podría resultar en daños por el calor o un incendio. I 1½” (3.8 cm) Min. C G F Orificio para el Cable H 48 5/8” (123.5 cm) B 3” (7.6 cm) Max. 11½” (29.2 cm) Puerta Abierta (vea la nota 2) 2” (5.1 cm) Min. Espaciador D A Espaciador de Madera de 2" (5 cm) de ancho, si es necesario NOTES: 1. La base debe poder sostener 300 libras (136 kg) para los modelos 27" y la base debe poder sostener 375 libras (170 kg) para los modelos 30". 2. Deje por lo menos 21" (53.3 cm) de espacio libre para la profundidad de la puerta cuando esta abierta. 3. La dimensión G (profundidad del corte) está primordial para instalar correctamente el horno de pared. Si el adorno del armazón del horno no topa contra el armario, o si escuche un ruido, verifique Caja eléctrica de empalme si la dimensión G está en conformidad con la dimensión requerida. 4. Para un corte de una profundidad mayor que 49½" (125.7 cm) agregar una cuña de madera de 2" (5 cm) de ancho para lograr la altura apropiada a cada lado del orificio ubicado debajo de los rieles laterales del accesorio. 5. MODELOS 30" SOLAMENTE: Para un corte de una altura (H) mayor que 497/8" (126.7 cm) una moldura grande inferior puede ser pedido con su representante. Figura 2 HORNOS DOBLES DE 27" Y 30" (Para hornos simples, ver la Figura 1) DIMENSIONES DEL APARATO MODELO A B C Horno de pared 27" (68.6cm) 27 (68.6) 50 /16 (128.1) 24 /8 (62.5) 24¾ (62.2) Horno de pared 30" (76.2cm) 30 (76.2) 507/16 (128.1) 28¼ (71.8) 24¾ (62.2) 7 D 5 DIMENSIONES DEL HUECO Y ANCHURA DEL ARMARIO F G (Mín.) MODELO Mín. Máx. Horno de pared 27" (68.6cm) 24 /8 (63.2) 25¼ (64.1) Horno de pared 30" (76.2cm) 28½ (72.4) 29 (73.7) 7 H. Altura estándar (**Otras, vea notas 4 & 5) I Mín. Máx. 23½ (59.7) 48 /8 (124.1) 49 /8 (126.7) 271/8 (68.9) Mín 23½ (59.7) 487/8 (124.1) 497/8 (126.7) 301/8 (76.5) Mín Todas las dimensiones se dan en pulgadas (cm). 10 7 7 INSTRUCCIONES DE INSTALACIÓN PARA EL HORNO ELÉCTRICO DE PARED (Combinado con una cocina eléctrica o de gas facultativa) Notas importantes para el instalador 1. Lea todas las instrucciones contenidas en este manual antes de instalar el horno. 2. Saque todo el material usado en el embalaje del compartimiento del horno antes de conectar el suministro eléctrico o de gas a la estufa. 3. Observe todos los códigos y reglamentos pertinentes. 4. Deje estas instrucciones con el consumidor. 5. La puerta del horno se puede retirar para facilitar la instalación. 6. ESTE HORNO NO ESTÁ APROBADO PARA LA INSTALACIÓN APILABLE O DE LADO A LADO. Nota importante al consumidor Conserve estas instrucciones y el manual del usuario para uso del inspector local de electricidad y referencia futura. INSTRUCCIONES IMPORTANTES DE SEGURIDAD • Asegúrese de que su horno de pared sea instalado y puesto a tierra de forma apropiada por un instalador calificado o por un técnico de servicio. • Este horno de pared debe ser eléctricamente puesto a tierra de acuerdo con los códigos locales o, en su ausencia, con el Código Eléctrico Nacional ANSI/ NFPA No. 70–última edición en los Estados Unidos, o el Código Eléctrico Canadiense CSA Standard C22.1, Part 1, en Canadá. Pisar, apoyarse, o sentarse sobre la puerta de este horno de pared puede causar serias lesiones y daños al horno de pared. • Nunca use su horno de pared para calentar una habitación. El uso prolongado de la estufa sin la ventilación adecuada puede ser peligroso. La corriente eléctrica al horno debe estar apagada mientras se hacen las conexiones de líneas. Si no se apaga, daños serios o la muerte podrían resultar. 1. Carpintería Consulte la Figura 1 o la figura 2 para conocer las dimensiones pertinentes al modelo de su horno y al espacio necesario en el que poner el horno. La superficie donde se va a apoyar el horno debe de ser de madera contrachapada sólida u otro material similar y, sobre todo, la superficie tiene que estar a nivel, de lado a lado, y de atrás hacia adelante. 2. Ajuste de la altura del horno La altura del horno se puede ajustar con cuñas de madera de 2" (5 cm) de ancho, donde sea necesario, para que quepa en un gabinete o abertura existente, cuando la altura del corte es superior a 281/8" (71,4 cm) en el caso del horno único de pared o 49½” (125.7 cm) en el caso del horno doble de pared (ver la Figura 1 o 2). Colocar las cuñas de altura apropiada debajo de los rieles laterales del horno. 11 3. Requerimientos Eléctricos Se debe proveer el voltaje y la frecuencia apropiados a este electrodoméstico, y conectarse a un circuito individual correctamente puesto a tierra, protegido por un interruptor o un fusible. Para conocer el interruptor o fusible que requiere su modelo, vea la placa serial para encontrar la consumación del vatiaje y refiérase al cuadro A para encontrar el amperaje del interruptor o fusible. Observe todos los códigos que gobiernan y ordenanzas locales Grados de Vatios del lectrodoméstico 240V Se recomienda una protección al circuito Grados de Vatios del lectrodoméstico 208V Se recomienda una protección al circuito Menos de 4800W 20A Menos de 4100W 20A 4801W - 7200W 30A 4101W - 6200W 30A 7201W - 9600W 40A o 50A 6201W - 8300W 40A o 50A 9601W and + 50A 8301W and + 50A Table A 1. Un cable de 3 o 4 alambres monofásico 120/240 o 120/208 voltios, 60 hertzios es la única fuente eléctrica que requiere en un circuito separado en ambos lados de la línea (alambre negro y alambre rojo) (se recomienda un fusible o un interruptor de retraso de tiempo). No funda a cable neutro (alambre blanco). Se debe de tener precaución al combinar un horno de pared y una cubierta, refiérase a la placa de seria de cada uno de los aparatos. NOTA: Los tamaños y las conexiones del alambre deben conformarse con el tamaño del fusible y el grado de la aplicación de acuerdo con el código Eléctrico Nacional Americano ANSI/NFPA No. 70- ultima edición, o con el estándar CSA canadiense C22.1, código eléctrico canadiense, parte 1, y códigos y ordenanzas locales. No se debera usar extensiones para enchufar este electrodoméstico. Esto podría causar un incendio, choque eléctrico u otro tipo de daño personal. Si usted necesita un cable mas largo, puede ordenar un cable de 10" kit 903056-9010 llamando al centro de Servicio. 2. Este electrodoméstico debe conectarse a la caja de fusibles (o de cortocircuito), por medio de un cable blindado flexible o un cable con forro no metálico. El cable blindado flexible que va desde el electrodoméstico debe de estar conectado directamente a la caja de empalme. La caja de empalme debe de estar localizada en el lugar que se indica en la Figura 1 o 2, dejando tanto exceso de cable como sea posible entre la caja y el electrodoméstico, de forma que así el electrodoméstico se pueda mover fácilmente, si fuera necesario para hacer una reparación. 3. Se debe de usar un conector que reduzca la tirantez de una forma adecuada para unir el cable blindado flexible a la caja de empalme. INSTRUCCIONES DE INSTALACIÓN PARA EL HORNO ELÉCTRICO DE PARED (Combinado con una cocina eléctrica o de gas facultativa) (Si su electrodoméstico está equipado con un conductor neutro blanco.) Este electrodoméstico está fabricado con un suministro eléctrico neutro blanco y un alambre de cobre conectado al armazón. El armazón esta puesto a tierra por un enlace de la conexión a tierra con la conexión del neutro al final de la línea eléctrica, si es usado en los estados unidos una nueva instalación de circuito de bifurcación (1996 NEC), casa rodante, vehículos recreacionales, o donde los códigos locales no permitan poner a tierra mediante el neutro (blanco) o en Canadá, desconectar la conexión blanca de la verde y utilizar la conexión a tierra para poner a tierra la unidad de acuerdo a los códigos locales, conectar el neutro al circuito de bifurcación- conductor neutro de manera usual. Ver Figura 4. Si su electrodoméstico va a ser conectado a una caja de conexión puesta a tierra de 3 cables (en los estados unidos solamente), donde los códigos locales permitan conectar el conductor de poner a tierra-electrodoméstico con el neutro (blanco) ver Figura 3. Riesgo de choque eléctrico • Una puesta a tierra se requiere en este aparato. • No lo conecte a la corriente eléctrica hasta que el aparato haya sido puesto a tierra. • Desconecte la corriente eléctrica a la caja de empalmes antes de hacer la conexión eléctrica. • Este aparato debe estar conectado con un sistema de alambres puesto en tierra, metálico y permanente o un conector de puesta a tierra debe conectarse al terminal de puesta a tierra o el alambre conductor en al aparato. • No utilice el suministro de gas para hacer la puesta a tierra. La falta de cualquiera de las instrucciones mencionadas podría resultar en un incendio, choque eléctrico o lesiones personales. En cuanto a las condiciones de despacho y almacenamiento en el invierno, asegúrese de que el horno llegue a su destino final como mínimo tres (3) horas antes de encenderlo. Si se enciende el horno cuando aún está frío, se pueden dañar los controles. NOTA AL ELECTRICISTA: Los conductores de cable blindados provistos con este artefacto son aprobados por UL para la conexión al alambrado de casa de un calibre mayor. El aislamiento de los conductores está calificado para temperaturas más altas que las del alambrado de la casa. La capacidad de corriente del conductor está gobernada por la calificación de la temperatura del aislamiento alrededor del alambre en vez de solamente el calibre del alambre. 4. Conexión eléctrica El usuario tiene la responsabilidad personal y obligación de utilizar un instalador calificado, para asegurar que la instalación eléctrica está hacha de forma adecuada y está conforme con el Código Eléctrico Nacional ANSI/NFPA No. 70-última edición en los Estados Unidos, o el Código Eléctrico Canadiense CSA Standard C22.1, Part 1, en Canadá. Donde los códigos locales permitan conectar el conductor de puesta a tierra del electrodoméstico al neutral (blanco) (Solamente en los Estados Unidos) (vea figura 3): 1. Desconecte el suministro eléctrico. 2. En el caja de juntas: conectar el aparato y los cables residenciales como se muestra en la figura 3. Riesgo de choque eléctrico (El no prestar atención a esta advertencia puede resultar en electrocución u otras lesiones graves.) Este electrodoméstico está equipado con alambre de cobre. Si se va a conectar con cableado de aluminio del hogar, utilizar únicamente conectores que están aprobados para unir cobre y aluminio de acuerdo al Código Nacional Eléctrico (NEC por sus siglas en ingles) y leyes y códigos locales. Al instalar conectores con tornillos que empujen directamente contra el acero y/o aluminio del conducto flexible, no apretar los tornillos suficientemente que dañen el conducto flexible. No doblar de más o deformar el conducto flexible para evitar separar el espiral y descubrir los alambres internos. Cable desde el suministro de energía Alambre Alambre desnudo negros Alambre rojos NO conecte el alambre puesto a tierra a una tubería de suministro de gas. NO conecte el suministro de energía eléctrica hasta que el electrodoméstico haya sido permanentemente puesto a tierra. Conecte el alambre de puesto a tierra antes de enchufar por primera vez el electrodoméstico. Alambre verde o desnudo Caja de empalmes Alambre desnudo Conductor de unión listado-UL (o CSA) Cable de la estufa Figura 3 - CAJA DE EMPALMES DE 3 ALAMBRES PUESTA A TIERRA 12 INSTRUCCIONES DE INSTALACIÓN PARA EL HORNO ELÉCTRICO DE PARED (Combinado con una cocina eléctrica o de gas facultativa) 5. Instalación del Gabinete Si el horno se usa en una instalación de circuito de ramal nuevo (1996 NEC), en una casa rodante, en un vehículo para recreación o si los códigos locales NO permiten la conexión a tierra a través del cable neutral (blanco), el armazón del electrodoméstico NO TIENE QUE estar conectado al alambre neutro del sistema eléctrico de 4 alambres. (ver figura 4): 1. Desconecte el suministro eléctrico 2. Separe el alambre verde (o cobre desnudo) y el alambre blanco del electrodoméstico. 3. En el caja de juntas: conectar el aparato y los cables residenciales como se muestra en la figura 4. IMPORTANTE No levante el horno por la manija de la puerta. Peligro de Peso Pesado • Use 2 personas o más para mover e instalar el horno de pared. • Si no cumple con esta instrucción, puede resultar en lesiones personales o daños al horno de pared 1 Desembalar el horno de pared. Extraer la guarnición inferior y los 2 tornillos unidos con cinta al panel lateral del horno. 2 Buscar los tornillos que se incluyen en el paquete de literatura. 3 Insertar el horno en la abertura del gabinete. Deslizar el horno hacia dentro dejando 1½” (3,8 cm) de espacio libre entre el horno y la parte delantera del gabinete (ver la Figura 5). 4 Empujar el cable blindado a través del orificio del gabinete y hacia la caja de paso mientras se desliza el accesorio hacia adentro. 5 Empujar el horno hacia adentro y en contra del gabinete Cable desde el suministro de energía Alambre desnudo Alambre blanco Alambre rojos Alambre verde o desnudo Alambre negros Alambre blanco Conductor de unión listado-UL Cable de la estufa (o CSA) Figura 4- CAJA DE EMPALMES DE 4 ALAMBRES PUESTA A TIERRA Caja de empalmes Ubicación del número de modelo y de serie La placa con el número de serie está ubicada en la guarnición interior lateral del horno y se puede ver cuando se abre la puerta. Cuando haga pedidos de repuestos o solicite información con respecto a su horno, esté siempre seguro de incluir el número de modelo y de serie y el número o letra del lote de la placa de serie de su horno. 1 1/2" (3.8 cm) distancia entre la unidad y el gabinete Modelos con un solo hornola placa de serie está ubicada aquí. Figura 5 Modelos con un horno doble- la placa de serie está ubicada aquí. 13 INSTRUCCIONES DE INSTALACIÓN PARA EL HORNO ELÉCTRICO DE PARED (Combinado con una cocina eléctrica o de gas facultativa) 6 Instalación de los tornillos de montado 7 Instalación de la Guarnición Inferior: Colocar la parte superior de la guarnición inferior sobre las lengüetas laterales del horno, debajo de la puerta del horno, y fijarlas usando los 2 tornillos provistos con los orificios de montaje ubicados a cada lado del marco del horno (ver la Figura 7). El horno de pared puede inclinarse cuando la puerta esta abierta. Los soportes de montaje que vienen con el horno de pared deben de estar ajustadas al armario y al aparato para evitar que el horno de pared se incline y ocasione quemaduras graves. A. Los barrenos en las molduras laterales pueden ser usadas como guía para localizar los tornillos de montado de la unidad (figura 6). B. Use los dos tornillos proporcionados para colocar la unidad en la cabina. IMPORTANTE: La moldura inferior debe estar instalada para que el horno funcione correctamente. NO ponga el horno en funcionamiento sin que esté instalada la moldura del fondo del horno. Tornillos de montado Figura 6 Riesgo de volcamiento • Un niño o adulto puede volcar el horno y acabar muerto. • Instale el dispositivo antivuelco en el horno y/o en la estructura según las instrucciones de instalación. • Asegúrese de que el horno se vuelva a acoplar al dispositivo antivuelco cuando lo mueva. • No utilice el horno sin el dispositivo antivuelco instalado y acoplado. • Si no se siguen estas instrucciones, se puede provocar la muerte o quemaduras graves en niños y adultos. Tornillos provistos Guarnición Inferior Figura 7 Consulte las instrucciones de instalación proporcionadas con su electrodoméstico para instalarlo adecuadamente. Verifique que la instalación se haya realizado adecuadamente corroborando que los tornillos antivuelco estén colocados. Agujeros de instalación Pruebe la instalación ejerciendel dispositivo do poca presión hacia abajo antivuelco sobre la puerta abierta del horno. El horno no debe inclinarse hacia adelante. 14 INSTRUCCIONES DE INSTALACIÓN PARA EL HORNO ELÉCTRICO DE PARED (Combinado con una cocina eléctrica o de gas facultativa) Para una instalación típica de un horno eléctrico incorporado debajo del mostrador, véase la figura 8. Los paneles de relleno laterales del gabinete son necesarios para aislar la unidad de los gabinetes adyacentes. La altura del relleno lateral del gabinete debe permitir la instalación de modelos de tapas de cocina aprobados. Sólo ciertos modelos de tapas de cocina se pueden instalar sobre ciertos modelos de hornos eléctricos empotrados. Las tapas de cocina y los hornos empotrados se mencionan por su número de identificación MFG ID y código de producto (ver la planilla que se incluye en el paquete de literatura y las instrucciones de instalación de la cocina donde están detalladas las dimensiones). Para reducir el riesgo de lesiones personales y inclinación del horno de pared, éste debe asegurarse a los gabinetes mediante soportes de montaje. Approx. 3” (7.5 cm) 36” Min. (91.4cm) Min. G H 208/240 caja de empalme para hornos de pared F Instale contrachapado de 3/4" (1.9 cm) sobre dos correderas, nivelado con la parrilla inferior. La base debe poder sostener 150 libras (68 kg) para los modelos 27"y 200 libras (90 kg) para los modelos 30". Corte una abertura de 9" X 9"(23 cm X 23 cm) (mínimo) en el fondo del contrachapado, a 2" (5 cm) del lado izquierdo del panel llenador, para poder encaminar el cable a la caja de empalme. 4 1/2” (11.5 cm) Max.* DIMENSIONES DE ABERTURA * Si no se instala ninguna tapa de cocina directamente sobre la unidad del horno, se permite un espacio máximo de 5" (12,7 cm) sobre el piso. F. ANCHURA G. PROFUNDIDAD H. ALTURA 27" (68.6 cm) Horno de pared 247/8" (63.2 cm) Min. 25¼" (64.1 cm) Max. 23½" (59.7 cm) Min. 27¼" (69.2 cm) Min. 285/8" (72.7 cm) Max. 30" (76.2 cm) Horno de pared 28½" (72.4 cm) Min. 29" (73.7 cm) Max. 23½" (59.7 cm) Min. 27¼" (69.2 cm) Min. 285/8" (72.7 cm) Max. Figura 8 – INSTALACIÓN TÍPICA DEBAJO DE LA MESADA DE HORNO SIMPLE EMPOTRADO CON TAPA DE COCINA MONTADA 15 INSTRUCCIONES DE INSTALACIÓN PARA EL HORNO ELÉCTRICO DE PARED (Combinado con una cocina eléctrica o de gas facultativa) 18”(45.7 cm) Max. ESTUFA DE GAS 4”(10 cm) 5” Max. 6 1/2” Min. (12.7 cm) (16.5 cm) Adaptor de gas Conector flexible para artefactos Adaptor de gas Tomacorriente puesto a tierra de 120Voltios /60Hz Regulador de presión Lados del gabinete o panel llenador Válvula de cierre manual Gabinete del horno de pared Lado derecho del gabinete (para tener acceso a la válvula de cierre manual) Figura 9 - INSTALACIÓN TÍPICA PARA UNA ESTUFA DE GAS ENCIMA DE UN HORNO DE PARED INSTALADO DEBAJO DEL MOSTRADOR Hornear – Verificar que esta función caliente el horno. Veinte minutos después de encender el horno, abrir la puerta y ver si se siente que el calor emana desde su interior. Asar– Cuando se pone el horno para asar, el elemento de arriba del horno debe de ponerse rojo. Convección (algunos modelos) – Cuando se configura el horno para horneado o asado por convección, los dos elementos se encienden y apagan en forma alterna y se enciende el ventilador. El ventilador de convección dejará de funcionar cuando se abre la puerta del horno durante el horneado o asado por convección. 6. Asegúrese de que el horno de pared está a nivel 1. Instale una rejilla al centro del horno superior (vea la Figura 10). 2. Ponga un nivel por encima de la rejilla. Lea 2 veces, una vez con el nivel a la posición de lado a lado, y otra vez de atrás hacia adelante. Utilice trozo de madera o cuñas por debajo del horno de pared para nivelar, si sea necesario. 3. Vuelve a empezar en el horno inferior. Si el nivel muestra que la rejilla no esta a nivel, utilice trozo de madera o cuñas para componer ambos hornos. Antes de llamar al servicio Lea la sección Lista de Control de Averías en su Manual del Usuario. Esto le podrá ahorrar tiempo y gastos. Esta lista incluye ocurrencias comunes que no son el resultado de defectos de materiales o fabricación de este artefacto. Figura 10 Lea la garantía y la información sobre el servicio en su Manual del Usuario para obtener el número de teléfono gratuito. 7. Verificación del funcionamiento Su modelo está equipado con un Control Electrónico de Horno. Cada una de las funciones ha sido controlada en fábrica antes del despacho. Sin embargo, le sugerimos verificar el funcionamiento de los controles electrónicos una vez más. Consulte la Guía de Uso y Cuidado o la Guía del controles para ver el funcionamiento del horno. IMPORTANTE Un ventilador ubicado dentro de la parte trasera superior arriba del horno (en algunos modelos) permite la refrigeración de los componentes eléctricos y electrónicos de enfriamiento. Si el horno ha estado funcionando a altas temperaturas, el ventilador seguirá funcionando después de apagar el horno. 1. Extraer todos los elementos de la parte interior del horno. 2. Encender el horno (Consular la Guía de Uso y Cuidado.) 3. Verificar el funcionamiento de los controles electrónicos del horno: 16 INSTRUCTIONS D'INSTALLATION POUR FOUR ENCASTRÉ ÉLECTRIQUE (Combiné à une table de cuisson électrique ou à gaz (en option)) L’INSTALLATION ET L’ENTRETIEN DOIVENT ÊTRE EFFECTUÉS PAR UN INSTALLATEUR QUALIFIÉ. IMPORTANT: CONSERVEZ POUR L’INSPECTEUR D’ÉLECTRICITÉ LOCAL. LISEZ ET CONSERVEZ CES INSTRUCTIONS POUR RÉFÉRENCES ULTÉRIEURES. États-Unis et Canada POUR VOTRE SÉCURITÉ: N’entreposez pas ou n’utilisez pas d’essence ou d’autres produits inflammables à proximité de cet appareil ou de tout autre appareil électroménager. Votre nouveau four encastré a été conçu pour s’ajuster à différentes dimensions de découpage et en faciliter l’installation. La première étape de votre installation consiste à mesurer les dimensions du découpage actuel et, à les comparer au tableau de dimensions de découpage ci-dessous. Vous découvrirez peut-être que peu ou pas de modification sera nécessaire. N’enlevez pas les entretoises sur les parois latérales du four. Ces entretoises centrent le four dans l’espace fourni. Le four doit être centré pour prévenir une accumulation excessive de chaleur pouvant causer un feu ou des dommages. NOTE: I 1. La base doit pouvoir supporter 150 lbs (68 kg) pour les modèles 27" et 1½” (3.8 cm) 200 lbs (90 kg) pour les modèles 30". Min. 2. Allouez au moins 21" (53.3 cm) d'espace à l'avant du four pour Ouverture permettre l'ouverture complète de la porte du four. pour la 3. La dimension G (profondeur du C sortie du G découpage) est critique pour une câble bonne installation du four. Si la moulure F H inférieure du four ne vient pas s'accoter B 27 1/4” contre l'armoire, ou si un bruit se fait (69.2 cm) 3” entendre sur les modèles à convection, (7.6 cm) vérifiez la dimension G pour vous assurer qu'elle est correcte. 31”* 4. Si la hauteur de découpage est (78.7 cm) plus grande que 281/8" (71.4 Porte ouverte Entretoise D cm), ajoutez une entretoise de (voir note 2) 2” bois de 2" (5 cm) de largeur et (5.1 cm) de hauteur appropriée de chaque côté de A Min. Boîte de l'ouverture sous l'appareil. 5. MODÈLES 30" SEULEMENT: Si la hauteur de découpage jonction Entretoise de bois de 2" (H) est plus grande que 285/8" (72.7 cm), vous pouvez (5 cm) de largeur si nécessaire commander une assiette plus bas à travers un centre de service. * La distance suggérée du plancher est 31" (78.7 cm). La distance minimale requise est 41/2" (11.4 cm). Figure 1 Fours encastrés simples 27" et 30" (Pour les fours encastrés doubles voir la figure 2) DIMENSIONS DE L'APPAREIL MODÈLE A B C D 27" (68.6 cm) 27 (68.6) 29 (73.7) 245/8 (62.5) 24¾ (62.2) 30" (76.2 cm) 30 (76.2) 29 (73.7) 28¼ (71.8) 24¾ (62.2) DIMENSIONS DE DÉCOUPAGE ET DE L'ARMOIRE F G (Min.) MODÈLE Min. Max. 27" (68.6 cm) 247/8 (63.2) 25¼ (64.1) 30" (76.2 cm) 28½ (72.4) 29 (73.7) H. Hauteur standard (**autres, voir notes 4 & 5) I Min. Max. 23½ (59.7) 27¼ (69.2) 285/8 (72.7) 271/8 (68.9) Min 23½ (59.7) 27¼ (69.2) 28 /8 (72.7) 301/8 (76.5) Min Toutes les dimensions sont en pouces (cm). 5 PN 807153701 (1212) Rev. A Imprimé au U.S.A. 17 English – pages 1-8 Español – páginas 9-16 Français – pages 17-24 INSTRUCTIONS D'INSTALLATION POUR FOUR ENCASTRÉ ÉLECTRIQUE (Combiné à une table de cuisson électrique ou à gaz (en option)) N’enlevez pas les entretoises sur les parois latérales du four. Ces entretoises centrent le four dans l’espace fourni. Le four doit être centré pour prévenir une accumulation excessive de chaleur pouvant causer un feu ou des dommages. I 1½” (3.8 cm) Min. C G F Ouverture pour la sortie du câble H 48 5/8” (123.5 cm) B 3” (7.6 cm) Max. 11½” (29.2 cm) Porte ouverte (voir note 2) 2” (5.1 cm) Min. Entretoise D Entretoise de bois de 2" (5 cm) de largeur si nécessaire A NOTES: 1. La base doit pouvoir supporter 300 lbs (136 kg) pour les modèles 27" et 375 lbs pour les modèles 30". 2. Allouez au moins 21" (53.3 cm) d'espace à l'avant du four pour permettre l'ouverture complète de la porte du four. 3. La dimension G (profondeur du découpage) est critique pour une bonne installation du four. Si la moulure inférieure du four ne vient pas s'accoter contre l'armoire, ou si un bruit se fait entendre sur les modèles à convection, vérifiez la dimension G pour vous assurer qu'elle est correcte. Boîte de jonction 4. Si la hauteur de découpage est plus grande que 49½" (125.7 cm), ajoutez une entretoise de bois de 2" (5 cm) de largeur et de hauteur appropriée de chaque côté de l'ouverture sous l'appareil. 5. MODÈLES 30" SEULEMENT: Si la hauteur de découpage (H) est plus grande que 497/8" (126.7 cm), vous pouvez commander une moulure inférieure plus large en contactant un Centre de service. Figure 2 Fours encastrés doubles 27" et 30" (Pour les fours encastrés simples voir la figure 1) DIMENSIONS DE L'APPAREIL MODÈLE A B C D 27" (68.6 cm) 27 (68.6) 507/16 (128.1) 245/8 (62.5) 24¾ (62.2) 30" (76.2 cm) 30 (76.2) 50 /16 (128.1) 28¼ (71.8) 24¾ (62.2) 7 DIMENSIONS DE DÉCOUPAGE ET DE L'ARMOIRE F G (Min.) MODÈLE Min. Max. 27" (68.6 cm) 247/8 (63.2) 25¼ (64.1) 30" (76.2 cm) 28½ (72.4) 29 (73.7) H. Hauteur standard (**autres, voir notes 4 & 5) I Min. Max. 23½ (59.7) 487/8 (124.1) 497/8 (126.7) 271/8 (68.9) Min 23½ (59.7) 48 /8 (124.1) 49 /8 (126.7) 301/8 (76.5) Min Toutes les dimensions sont en pouces (cm). 18 7 7 INSTRUCTIONS D'INSTALLATION POUR FOUR ENCASTRÉ ÉLECTRIQUE (Combiné à une table de cuisson électrique ou à gaz (en option)) 3. Exigences électriques Installateur 1. Lisez toutes les instructions contenues dans ce feuillet avant l’installation du four encastré. 2. Enlevez tout le matériel d’emballage du four avant de procéder au raccordement électrique. 3. Observez tous les codes et règlements applicables. 4. Assurez-vous de laisser ces instructions au consommateur. 5. La porte du four peut être enlevée pour faciliter l'installation. 6. CE FOUR N'EST PAS HOMOLOGUÉ POUR UNE INSTALLATION CÔTE-À-CÔTE OU SUPERPOSÉE. Ces appareils doivent être branchés à une alimentation possédant la tension et la fréquence appropriées. Ils doivent être connectés à un circuit dédié correctement mis à la terre et protégé par un disjoncteur ou un fusible. Pour savoir quel disjoncteur ou fusible utiliser avec cet appareil, référez-vous à la plaque signalétique pour connaître la consommation (watts) et avec cette donnée, consultez la table A pour connaître l'ampérage requis du disjoncteur ou du fusible. Consommateur Conservez ces instructions avec votre Manuel d'utilisation et d'entretien pour l'inspecteur d'électricité local et références futures. DIRECTIVES IMPORTANTES DE SÉCURITÉ • Assurez-vous que votre four encastré est installé et mis à la terre conformément par un installateur ou un technicien de service qualifié. • Ce four encastré doit être mis à la terre conformément aux codes locaux d'électricité ou, en l'absence de codes, en conformité avec le National Electrical Code ANSI/NFA No. 70, dernière édition aux États-Unis, ou avec la norme ACNOR C22.1, Partie 1, au Canada. Calibre de l'appareil (Watts) 240V Circuit de protection recommandé Calibre de l'appareil (Watts) 208V Circuit de protection recommandé Moins de 4800W 20A Moins de 4100W 20A 4801W - 7200W 30A 4101W - 6200W 30A 7201W - 9600W 40A ou 50A 6201W - 8300W 40A ou 50A 9601W et + 50A 8301W et + 50A Table A Observez tous les règlements et les codes locaux applicables. 1. Un câble électrique à 3 ou 4 fils de 120/240 ou 120/208 Volt monophasé, 60 Hz CA est requis sur un circuit séparé muni d’un fusible sur chaque fil conducteur (fusible temporisé ou disjoncteur recommandé). NE RELIEZ PAS de fusible au neutre. Il faut tenir compte de l'ajout d'une plaque de cuisson superposée au four encastré. Référez-vous à la plaque signalétique de chaque unité. Grimper, s'appuyer ou s'asseoir sur la porte de ce four encastré peut entraîner des blessures graves et peut aussi causer des dommages au four encastré. NOTE: Le calibre des fils et leurs connexions doivent être conformes à la capacité des fusibles et à la capacité nominale de l’appareil, selon le National Electrical Code ANSI/NFPA No. 70, dernière édition, ou selon la norme ACNOR C22,1, Partie 1, du Code canadien de l’électricité et les codes et les règlements locaux. • N’utilisez jamais votre four encastré pour chauffer ou réchauffer la pièce. L’utilisation prolongée du four encastré sans ventilation adéquate peut être dangereuse. Il faut couper l’alimentation électrique durant le montage des connexions électriques. À défaut de ce faire il peut en résulter des blessures graves ou la mort. N’utilisez pas de rallonge électrique avec ces appareils. Son utilisation peut causer un feu, un choc électrique ou des blessures corporelles. Si un câble d'alimentation plus long est requis, vous pouvez vous en procurer un de 10' (3 m) en téléphonant au centre de service et en demandant le kit #9030569010. 1. Travaux de menuiserie Reportez-vous à la figure 1 ou à la figure 2 pour établir quelles sont les dimensions applicables à votre modèle, ainsi que l'espace nécessaire pour recevoir l'appareil. La surface qui supporte l'appareil doit être en contre-plaqué solide ou tout autre matériau du même type. Il faut vous assurer que la surface est de niveau d'un côté à l'autre et de l'avant à l'arrière. 2. Il faut brancher l’appareil au panneau de distribution en utilisant des câbles flexibles à gaine métallique ou non métallique. On doit brancher directement à la boîte de jonction le câble gainé flexible de l’appareil. Il faut disposer la boîte de jonction tel qu’illustré à la Figure 1 ou 2 en laissant autant de lâche que possible dans le câble entre la boîte et l’appareil, pour en faciliter le déplacement si l’entretien s’avère nécessaire. 3. Une attache de protection sécuritaire doit retenir le câble armé flexible à la boîte de jonction. 2. Réglage de la hauteur du four encastré Lorsque requis, ce four peut être ajusté en hauteur avec une entretoise en bois d’une largeur de 2" (5 cm) pour en permettre l’installation dans le découpage existant d’une armoire, si la hauteur du découpage excède la dimension 281/8" (71.4 cm) pour un four encastré simple ou 49½" (125.7 cm) pour un four encastré double (voir la figure 1 ou 2). Placez l'entretoise de hauteur appropriée de chaque côté de l'ouverture sous l'appareil. 19 INSTRUCTIONS D'INSTALLATION POUR FOUR ENCASTRÉ ÉLECTRIQUE (Combiné à une table de cuisson électrique ou à gaz (en option)) (Si votre appareil possède un câble muni d'un conducteur blanc neutre.) Cet appareil est fabriqué avec un câble d’alimentation muni d’un fil blanc neutre et d’un fil de mise à la terre en cuivre branché sur le châssis. Si l'appareil est utilisé, aux États-Unis, dans une maison mobile, un nouveau branchement (1996 NEC), un véhicule récréatif où les codes locaux n'autorisent pas la connexion du conducteur de mise à la terre du châssis au neutre ou au Canada, débranchez les fils blanc et vert des autres et utilisez le fil de mise à la terre pour mettre à la terre l'appareil conformément aux codes locaux, branchez le conducteur neutre de manière habituelle au circuit neutre voir la figure 4. Si l'appareil doit être branché à un câble à 3 fils (aux États-Unis seulement), où les codes locaux permettent la connexion du fil de mise à la terre du châssis au neutre (blanc). Voir la figure 3. Risque de choc électrique • La mise à la terre de cet appareil est obligatoire. • Ne branchez pas l’appareil au circuit électrique tant qu’il ne sera pas mis à la terre correctement et en permanence. • Coupez l’alimentation à la boîte de jonction avant de faire les raccords électriques. • Cet appareil doit être connecté à un circuit permanent électrique, métallique et mis à la terre, ou à un connecteur de mise à la terre qui doit être branché à la borne ou au fil de mise à la terre de l’appareil. • N’utilisez pas un tuyau d’alimentation de gaz pour la mise à la terre de l’appareil. Si vous ne respectez pas toutes les instructions précédentes, un feu, des blessures corporelles ou un choc électrique peuvent en résulter. ÉLECTRICIEN: Le câble gainé fourni avec cet appareil est homologué par UL pour connexion à des circuits résidentiels de fils de calibre supérieur. La capacité thermique de l'isolant des câbles excède considérablement celle des circuits résidentiels. La transmission du courant électrique maximum permise des fils du câble est en fonction de la capacité thermique de la gaine plutôt que du calibre du fil. Par temps froid, pour protéger la commande du four, il faut attendre au moins trois (3) heures à la température de la pièce avant de mettre l'appareil sous tension. Ceci évitera toute possibilité d'endommager la commande du four lors de la mise sous tension. Si les codes locaux permettent la connexion du fil de mise à la terre du châssis au neutre (blanc) (aux États-Unis seulement) (voir figure 3): 1. Coupez l’alimentation à la boîte de jonction. 2. Dans la boîte de jonction: Raccordez les fils de l'appareil à ceux du circuit électrique tel que montré à la figure 3. 4. Connexions électriques Le consommateur est responsable et doit communiquer avec un installateur qualifié pour s'assurer que l'installation électrique est adéquate et conforme avec le National Electrical Code ANSI/NFPA No. 70-dernière édition, ou avec la norme ACNOR C22.1, partie 1, du code canadien de l'électricité, et les codes et règlements locaux. Câble d'alimentation Risque de choc électrique (Si cet avertissement n'est pas pris en considération, un choc électrique ou des blessures sérieuses peuvent survenir). Cet appareil est muni de fils en cuivre. Si ce dernier est branché à circuit résidentiel en aluminium, n'utilisez que des connecteurs qui sont approuvés pour joindre des fils de cuivre à des fils d'aluminium conformément au National Electrical Code et les codes et règlements locaux. Lors de l’installation des connecteurs munis de vis touchant directement l’acier ou l’aluminium de conduit flexible, il ne faut pas serrer celles-ci outre mesure afin d’éviter d’endommager le conduit flexible. Il ne faut ni plier ni tordre outre mesure un conduit flexible de manière à éviter un bris dans la gaine et une exposition des fils ou câbles internes. Fil dénudé Fils noirs Fils rouges Boîte de jonction Fil blanc Fil dénudé ou vert Connecteur homologué- U.L. (ou ACNOR) Câble de l'appareil Figure 3 BOÎTE DE JONCTION À 3 FILS MISE À LA TERRE NE connectez pas le fil de mise à la terre à un tuyau d’alimentation de gaz. Ne branchez pas l’appareil au circuit électrique avant qu’il soit mis à la terre correctement, en permanence. Branchez le conducteur de mise à la terre avant de mettre l’appareil sous tension. 20 INSTRUCTIONS D'INSTALLATION POUR FOUR ENCASTRÉ ÉLECTRIQUE (Combiné à une table de cuisson électrique ou à gaz (en option)) 5. Installation dans l'armoire Câble d'alimentation IMPORTANT Fil dénudé Ne soulevez pas l'appareil par la poignée de la porte. Fil blanc Fils rouges Risque de lourde charge Fils noirs Fil dénudé ou vert Boîte de jonction Câble de l'appareil • Soyez 2 personnes ou plus pour installer ou déplacer l'appareil. • Des blessures ou des dommages à l'appareil peuvent survenir si vous ne suivez pas cette instruction. Fil blanc Connecteur homologué- U.L. (ou ACNOR) 1 Déballez le four encastré et récupérez la moulure inférieure qui est fixée sur le côté du four 2 Localisez les vis de fixation qui se trouvent dans l'enveloppe littérature. 3 Insérez l’appareil dans le découpage de l’armoire. Glissez l’unité vers l’intérieur en laissant un espace de 1½" (3.8 cm) entre le four et le devant de l’armoire (voir figure 5). 4 Tout en glissant l’appareil dans l'armoire, tirez le câble gainé à travers le trou du plancher de l’armoire et vers la boîte de jonction. 5 Poussez l'appareil complètement dans l'armoire. Figure 4 - BOÎTE DE JONCTION À 4 FILS MISE À LA TERRE Si l’appareil est utilisé dans une maison mobile, un nouveau branchement (1996 NEC), un véhicule récréatif ou si les codes locaux N'AUTORISENT PAS la connexion du conducteur de mise à la terre du châssis au neutre, le châssis de l'appareil NE DOIT PAS être branché au fil neutre du câble à 4 fils (voir le figure 4): 1. Coupez l’alimentation à la boîte de jonction. 2. Séparez le fil blanc du fil dénudé en cuivre de mise à la terre du câble d’alimentation de l’appareil. 3. Dans la boîte de jonction: Raccordez les fils de l'appareil à ceux du circuit électrique tel que montré à la figure 4. Emplacement des numéros de modèle et de série La plaque signalétique est située sur le côté intérieur de la moulure latérale. Pour toute commande de pièces ou demande de renseignement au sujet de votre appareil, assurezvous d'inclure les numéros de modèle et de série, ainsi que le numéro ou lettre de lot de la plaque signalétique de votre four. Espace d'environ 1½" (3.8 cm) Emplacement de la plaque signalétique des fours encastrés simples Figure 5 Emplacement de la plaque signalétique des fours encastrés doubles 21 INSTRUCTIONS D'INSTALLATION POUR FOUR ENCASTRÉ ÉLECTRIQUE (Combiné à une table de cuisson électrique ou à gaz (en option)) 6 Installez les vis de fixation 7 Le four encastré peut basculer quand la porte est ouverte. Il faut fixer l'appareil à l'armoire, à l'aide des vis de fixation fournis, pour prévenir le renversement du four et des blessures corporelles. A. Les trous situés sur les moulures latérales peuvent servir de gabarit (voir la figure 6). B. Utilisez les deux vis fournies pour fixer l'appareil à l'armoire. Installation de la moulure inférieure: Placez le haut de la moulure inférieure par dessus les petites languettes de chaque côté du four encastré, sous la porte. Vissez la moulure dans les trous situés de chaque côté de l'appareil en utilisant les vis fournies avec la moulure (voir la figure 7). IMPORTANT : la garniture inférieure doit être installée pour que le four fonctionne adéquatement. N'utilisez PAS le four sans avoir installé la garniture inférieure. Trous des vis de fixation Figure 6 Risque de basculement • Un enfant ou un adulte peut faire basculer la cuisinière et en décéder. • Installez le dispositif anti-renversement sur la cuisinière et/ou la structure selon les instructions d'installation. • Assurez-vous d'enclencher de nouveau le dispositif anti-renversement lorsque la cuisinière est déplacée. • Ne faites pas fonctionner la cuisinière si le dispositif anti-renversement n'est pas en place et enclenché. • Le non-respect de ces instructions peut causer des blessures fatales ou de graves brûlures aux enfants et aux adultes. Vis fournies Moulure inférieure Figure 7 Pour une installation adéquate du dispositif anti-renversement, reportez-vous aux instructions d'installation fournies avec votre cuisinière. Effectuez une vérification visuelle de la présence des vis du dispositif anti-renversement Trous de montage du pour vous assurer qu'il a été dispositif anti-renverse- installé correctement. ment Vérifiez l'installation du dispositif en ouvrant la porte du four et en appliquant sur cette dernière une légère pression vers le bas. La cuisinière ne devrait pas basculer vers l'avant. 22 INSTRUCTIONS D'INSTALLATION POUR FOUR ENCASTRÉ ÉLECTRIQUE (Combiné à une table de cuisson électrique ou à gaz (en option)) L'installation typique d'un four encastré électrique sous le comptoir est présentée à la figure 8. Seulement certains modèles de tables de cuisson peuvent être installés au-dessus de certains modèles de fours encastrés. Les modèles approuvés pour être combinés sont identifiés à l'aide d'un numéro MGF ID et d'un code de produit (Consultez la feuille qui se trouve dans l'enveloppe de littérature ainsi que le feuillet d'instructions d'installation de la table de cuisson pour les dimensions). Il faut fermer les côtés de l'habitacle par des panneaux de bois pour isoler l'appareil des armoires de chaque côté. La hauteur de ces panneaux doit faire en sorte que l'installation des modèles de tables de cuisson au dessus soit possible. Approx. 3” (7.5 cm) Pour réduire les risques de blessures et pour empêcher le four encastré de basculer. Utilisez les supports de fixation pour retenir le four encastré à l'armoire. 36” Min. (91.4 cm) Min. G H 208/240 Volt, boîte de jonction pour le four encastré F Utilisez un contre-plaqué de ¾" (1.9 cm) d'épaisseur monté sur deux solives et à égalité avec le coup-depied. La base doit pouvoir supporter 150 lbs (68 kg) pour les modèles 27" et 200 lbs (90 kg) pour les modèles 30". Découpez une ouverture de 9" X 9" (23 cm X 23 cm), à 2" (5 cm) du côté gauche du plancher pour la sortie du câble armé de l'appareil vers la boîte de jonction. 4½” (11.5 cm) Max. DIMENSIONS DE L'OUVERTURE F. LARGEUR G. PROFONDEUR H. HAUTEUR Four encastré 27" (68.6 cm) 247/8" (63.2 cm) Min. 25¼" (64.1 cm) Max. 23½" (59.7 cm) Min. 27¼" (69.2 cm) Min. 285/8" (72.7 cm) Max. Four encastré 30" (76.2 cm) 28½" (72.4 cm) Min. 29" (73.7 cm) Max. 23½" (59.7 cm) Min. 27¼" (69.2 cm) Min. 285/8" (72.7 cm) Max. Figure 8 - INSTALLATION TYPIQUE D'UN FOUR ENCASTRÉ SIMPLE SOUS LE COMPTOIR AVEC UNE TABLE DE CUISSON ÉLECTRIQUE OU À GAZ INSTALLÉE PAR-DESSUS 23 INSTRUCTIONS D'INSTALLATION POUR FOUR ENCASTRÉ ÉLECTRIQUE (Combiné à une table de cuisson électrique ou à gaz (en option)) 18”(45.7 cm) Max. TABLE DE CUISSON À GAZ 4”(10 cm) 5” Max. (12.7 cm) Raccord évasé 6 1/2” Min. (16.5 cm) Conduit à gaz flexible Raccord évasé Prise 120V/60Hz mise à la terre Régulateur de pression Armoire où le four est installé Côtés de l'armoire ou panneau de fermeture Côté droit de l'armoire (Accès facile pour fermer la robinet) Robinet de fermeture manuel Figure 9 - INSTALLATION TYPIQUE D'UNE TABLE DE CUISSON À GAZ MONTÉE AU DESSUS D'UN FOUR ENCASTRÉ ÉLECTRIQUE MONTÉ SOUS LE COMPTOIR 6. Mise à niveau du four encastré 1. 2. 3. 7. Vérification du fonctionnement Installez une grille au centre du four supérieur. Déposez un niveau à bulle sur la grille (voir la figure 10). Prenez 2 lectures en plaçant le niveau en diagonale dans une direction, puis dans l’autre direction. Utilisez des entretoises de bois sous le four encastré pour niveler si nécessaire. Si vous avez un four encastré double, répétez les mêmes étapes dans le four inférieur. Si le niveau à bulle indique que la grille n'est pas à niveau, utilisez des entretoises de bois pour trouver un ajustement adéquat pour les deux fours. Si votre appareil possède une commande électronique de four. Toutes les fonctions qu'elle contrôle ont été vérifiées en usine pour leur bon fonctionnement avant que l'appareil soit expédié. Cependant, nous vous suggérons de vérifier à nouveau le fonctionnement de la commande électrique. Reportez-vous à votre Manuel d'utilisation et d'entretien pour le réglage du four. 1. Retirer tous les items du four avant de procéder à la vérification. 2. Mettre l'appareil sous tension. 3.Vérifier les opérations de la commande électronique: Cuisson–Vérifier que lorsque le four est en fonction cuisson, l'élément de cuisson chauffe. 20 secondes après avoir programmé le four en mode cuisson, si en ouvrant la porte vous sentez de la chaleur s'échapper du four, c'est qu'il fonctionne. Grillage–L'élément du haut rougit lorsque le four est réglé pour le mode grillage. Convection–Si le four est réglé pour la cuisson ou le rôtissage par convection, les deux éléments cyclent et le ventilateur convection situé à l'arrière tourne. Le ventilateur convection arrête lorsque l'on ouvre la porte du four. Figure 10 Avant d'appeler le service d'entretien NOTE IMPORTANTE Une soufflerie située dans la partie interne supérieure à l'arrière de l'appareil permet de garder les composantes électriques et électroniques internes froides. Il est donc possible que la soufflerie continue de fonctionner même après l’arrêt de l’appareil, et ce, jusqu’à ce que les composantes aient refroidi. Réviser la liste de vérifications préventives et les instructions d'opération dans votre Manuel d'utilisation et d'entretien. Vous sauverez probablement du temps et de l'argent. La liste contient les incidents ordinaires ne résultant pas de défectuosités dans le matériel ou la fabrication de cet appareil. 24 Pour obtenir notre adresse et notre numéro de téléphone sans frais, référez-vous à votre Manuel d'utilisation et d'entretien.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Kenmore FFET2725PW Guía de instalación

Categoría
Microondas
Tipo
Guía de instalación
Este manual también es adecuado para