1) Turn off power.
2) Attach mounting strap to outlet box. (Screws not provided)
3) Thread hexnut onto threaded pipe so that 5 threads are exposed above
hexnut. Thread that end of threaded pipe into mounting strap and
tighten hexnut against mounting strap.
4) Grounding instructions: (See Illus. A or B).
A) On fixtures where mounting strap is provided with a hole and
two raise dimples. Wrap ground wire from outlet box around
green ground screw, and thread into hole.
B) On fixtures where a cupped washer is provided. Attach ground
wire from outlet box under cupped washer and green ground
screw, and thread into mounting strap.
If fixture is provided with ground wire. Connect fixture ground wire to
outlet box ground wire with wire connector. (Not provided.) After following
the above steps.
Never connect ground wire to black or white power supply wires.
5) Make wire connections (connectors not provided.) Reference chart
below for correct connections and wire accordingly.
6) Push fixture to wall, carefully passing threaded pipe through hole.
7) Secure fixture to wall using threaded cap.
8) Insert recommended bulb.
INSTRUCTIONS FOR MOUNTING FIXTURE OUTDOORS AND/OR
IN WET LOCATIONS.
9) Mounting surface should be clean, dry, flat and 1/4” larger that the
canopy on all sides. Any gaps between the mounting surface and
canopy exceeding 3/16” should be corrected as required.
10) With silicone caulking compound, caulk completely around where back
of canopy meets the wall surface to prevent water from seeping into
outlet box.
GREEN GROUND
SCREW
CUPPED
WASHER
A
B
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
(NOT PROVIDED)
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth) *Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire
Date Issued: 6/19/09 IS-49059-US
THREADED CAP
TAPA ROSCADA
1) Desconecte la corriente.
2) Sujete la plancha para montar a la caja de conexión. (No se proveen
los tornillos.)
3) Atornille la tuerca hexagonal en el tubo roscado de manera que 5 hilos
de rosca estén expuestos arriba de la tuerca hexagonal. Atornille el
extremo del tubo roscado en la plancha para montaje y apriete la tuerca
hexagonal contra la plancha para montaje.
4) Instrucciones de conexión a tierra solamente para los Estados Unidos.
(Vea la ilustracion A o B).
A) En las lámparas que tienen el fleje, de montaje con un agujero
y dos hoyuelos realzados. Enrollar el alambre a tierra de la caja
tomacorriente alrededor del tornillo verde y pasarlo por el aquiero.
B) En las lámparas con una arandela acopada. Fijar el alambre a
tierra de la caja tomacorriente del ajo de la arandela acoada y
tornillo verde, y paser por el fleje de montaje.
Si la lámpara viene con alambre a tierra. Conecter el alambre a tierra
de la lámpara al alambre a tierra de la caja tomacorriente con un conector
de alambres. (No incluido) Espués de seguir los pasos anteriores.
Nunca conectar el alambra a tierra a los alambres eléctros negro o
blanco.
5) Haga les conexiones de los alambres (no se proveen los connectores.)
La tabla de referencia de abajo indica las conexiones correctas y los
alambres correspondientes.
6) Empuje el artefacto a la pared pasando cuidadosamente el tubo
roscado a través del agujero.
7) Sujete la unidad contra la pared apretándola con la tapa roscada.
8) Inserte las bombillas recomendadas.
INSTRUCCIONES PARA EL MONTAJE DEL ARTEFACTO AL AIRE
LIBRE Y/O EN UN LUGAR MOJADO.
9) La superficie de montaje debe estar limpia, seca, ser plana y 1/4” más
grande que el esdudete en todos los bordes. Cualquier espacio libre
entre la superficie de montaje y el escudete que exceda de 3/16” debe
corregirse según se requiera.
10) Calafatee totalmente con compuesto de calafatear de silicona alrededor
donde el escudete sienta en la superficie de la pared para impedir la
entrada de agua en la caja de conexiones.
Conectar el alambre de
suministro negro o rojo al
Conectar el alambre de
suministro blanco al
Negro Blanco
*Cordon paralelo (redondo y liso)
*Cordon paralelo (cuadrado y estriado)
Claro, marrón, amarillio o negro
sin hebra identificadora
Claro, marrón, amarillio o negro
con hebra identificadora
Alambre aislado (diferente del verde)
con conductor de cobre
Alambre aislado (diferente del
verde) con conductor de plata
*Nota: Cuando se utiliza alambre paralelo
(SPT I y SPT II). El alambre neutro es de forma
cuadrada o estriada y el otro alambre será de
forma redonda o lisa. (Vea la ilustracíón).
Hilo Neutral
THREADED PIPE
TUBO ROSCADO
MOUNTING STRAP
PLANCHA PARA MONTAR
ARANDELA
CONCAVA
A
B
TIERRA DE LA
CAJA DE SALIDA
TORNILLO DE TIERRA,
VERDE
DEPRESIONES
TIERRA
ARTEFACTO
CONECTOR DE ALAMBRE
(NO SE PROVEE)
TIERRA DE LA
CAJA DE SALIDA
TORNILLO DE TIERRA,
VERDE
TIERRA
ARTEFACTO
FIXTURE
ARTEFACTO

Transcripción de documentos

mounting STRAP PLANCHA PARA MONTAR THREADED CAP TAPA ROSCADA FIXTURE ARTEFACTO threaded pipe tubo roscado 1) Turn off power. 2) Attach mounting strap to outlet box. (Screws not provided) 3) Thread hexnut onto threaded pipe so that 5 threads are exposed above hexnut. Thread that end of threaded pipe into mounting strap and tighten hexnut against mounting strap. 4) Grounding instructions: (See Illus. A or B). A) On fixtures where mounting strap is provided with a hole and two raise dimples. Wrap ground wire from outlet box around green ground screw, and thread into hole. B) On fixtures where a cupped washer is provided. Attach ground wire from outlet box under cupped washer and green ground screw, and thread into mounting strap. If fixture is provided with ground wire. Connect fixture ground wire to outlet box ground wire with wire connector. (Not provided.) After following the above steps. Never connect ground wire to black or white power supply wires. A B WIRE CONNECTOR (NOT PROVIDED) OUTLET BOX GROUND FIXTURE GROUND FIXTURE GROUND DIMPLES GREEN GROUND SCREW GREEN GROUND SCREW Connect White Supply Wire to: Black White *Parallel cord (round & smooth) *Parallel cord (square & ridged) Clear, Brown, Gold or Black without tracer Clear, Brown, Gold or Black with tracer Insulated wire (other than green) with copper conductor Insulated wire (other than green) with silver conductor Neutral Wire 6) Push fixture to wall, carefully passing threaded pipe through hole. 7) Secure fixture to wall using threaded cap. 8) Insert recommended bulb. INSTRUCTIONS FOR MOUNTING FIXTURE OUTDOORS AND/OR IN WET LOCATIONS. 9) Mounting surface should be clean, dry, flat and 1/4” larger that the canopy on all sides. Any gaps between the mounting surface and canopy exceeding 3/16” should be corrected as required. 10) With silicone caulking compound, caulk completely around where back of canopy meets the wall surface to prevent water from seeping into outlet box. Date Issued: 6/19/09 B CONECTOR DE ALAMBRE (NO SE PROVEE) TIERRA ARTEFACTO TIERRA ARTEFACTO CUPPED WASHER 5) Make wire connections (connectors not provided.) Reference chart below for correct connections and wire accordingly. *Note: When parallel wires (SPT I & SPT II) are used. The neutral wire is square shaped or ridged and the other wire will be round in shape or smooth (see illus.) A TIERRA DE LA CAJA DE SALIDA OUTLET BOX GROUND Connect Black or Red Supply Wire to: 1) Desconecte la corriente. 2) Sujete la plancha para montar a la caja de conexión. (No se proveen los tornillos.) 3) Atornille la tuerca hexagonal en el tubo roscado de manera que 5 hilos de rosca estén expuestos arriba de la tuerca hexagonal. Atornille el extremo del tubo roscado en la plancha para montaje y apriete la tuerca hexagonal contra la plancha para montaje. 4) Instrucciones de conexión a tierra solamente para los Estados Unidos. (Vea la ilustracion A o B). A) En las lámparas que tienen el fleje, de montaje con un agujero y dos hoyuelos realzados. Enrollar el alambre a tierra de la caja tomacorriente alrededor del tornillo verde y pasarlo por el aquiero. B) En las lámparas con una arandela acopada. Fijar el alambre a tierra de la caja tomacorriente del ajo de la arandela acoada y tornillo verde, y paser por el fleje de montaje. Si la lámpara viene con alambre a tierra. Conecter el alambre a tierra de la lámpara al alambre a tierra de la caja tomacorriente con un conector de alambres. (No incluido) Espués de seguir los pasos anteriores. Nunca conectar el alambra a tierra a los alambres eléctros negro o blanco. DEPRESIONES TIERRA DE LA CAJA DE SALIDA TORNILLO DE TIERRA, VERDE TORNILLO DE TIERRA, VERDE ARANDELA CONCAVA 5) Haga les conexiones de los alambres (no se proveen los connectores.) La tabla de referencia de abajo indica las conexiones correctas y los alambres correspondientes. Conectar el alambre de suministro negro o rojo al Conectar el alambre de suministro blanco al Negro Blanco *Cordon paralelo (redondo y liso) *Cordon paralelo (cuadrado y estriado) Claro, marrón, amarillio o negro sin hebra identificadora Claro, marrón, amarillio o negro con hebra identificadora Alambre aislado (diferente del verde) con conductor de cobre Alambre aislado (diferente del verde) con conductor de plata *Nota: Cuando se utiliza alambre paralelo (SPT I y SPT II). El alambre neutro es de forma cuadrada o estriada y el otro alambre será de forma redonda o lisa. (Vea la ilustracíón). Hilo Neutral 6) Empuje el artefacto a la pared pasando cuidadosamente el tubo roscado a través del agujero. 7) Sujete la unidad contra la pared apretándola con la tapa roscada. 8) Inserte las bombillas recomendadas. INSTRUCCIONES PARA EL MONTAJE DEL ARTEFACTO AL AIRE LIBRE Y/O EN UN LUGAR MOJADO. 9) La superficie de montaje debe estar limpia, seca, ser plana y 1/4” más grande que el esdudete en todos los bordes. Cualquier espacio libre entre la superficie de montaje y el escudete que exceda de 3/16” debe corregirse según se requiera. 10) Calafatee totalmente con compuesto de calafatear de silicona alrededor donde el escudete sienta en la superficie de la pared para impedir la entrada de agua en la caja de conexiones. IS-49059-US
  • Page 1 1

Kichler Lighting 49059OZ Manual de usuario

Tipo
Manual de usuario

En otros idiomas