Assembly Instructions
Item No: 2790 / 2794 / 2795
Les Instructions D’assemblage
Numéro d’article: 2790 / 2794 / 2795
Instrucciones De Montaje
Número del artículo: 2790 / 2794 / 2795
English Spanish French
1. Find a clear area in which you can work.
2. Unpack fixture and glass from carton.
3. Carefully review instructions prior to assembly.
1. Encontrar un área clara en la que se puede trabajar.
2. Desembale xture fi y el vidrio de la caja.
3. Revise cuidadosamente las instrucciones antes del montaje.
1. Trouvez un endroit clair dans lequel vous pouvez travailler.
2. Déballez fi xture et de verre du carton.
3. Examinez attentivement les instructions avant l'assemblage.
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUC-
TIONS (I.S. 18) AND ANY ADDITIONAL DIRECTIONS. TURN
POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS
REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL
AUTHORITIES FOR CODE REQUIREMENTS.
Make electrical connections from supply wire to fixture lead wires.
Refer to instruction sheet (I.S. 18) and follow all instructions to make
all necessary wiring connections. Then refer back to this sheet to
complete installation of this fixture.
ADVERTENCIA DE SEGURIDAD: CABLEADO DE LEER Y
INSTRUCCIONES DE CONEXIÓN A TIERRA (SI 18), E
INSTRUCCIONES ADICIONALES. VUELTA DE ALIMENTACIÓN
DURANTE LA INSTALACIÓN. SI SE REQUIERE UN NUEVO
CABLEADO, CONSULTE A UN ELECTRICISTA O AUTORI-
DADES LOCALES PARA REQUISITOS DEL CÓDIGO.
AVERTISSEMENT DE SÉCURITÉ: CÂBLAGE LIRE ET MISE A LA
TERRE (IS 18) ET TOUTE AUTRE INSTRUCTION. COUPER
L'ALIMENTATION PENDANT L'INSTALLATION. SI DE
NOUVELLES CÂBLAGE NE EST NÉCESSAIRE, CONSULTER UN
ÉLECTRICIEN QUALIFIÉ OU LES AUTORITÉS LOCALES LES
EXIGENCES DES CODES.
Haga las conexiones eléctricas del cable para suministrar cables
conductores de luz. Consulte la hoja de instrucciones (IS 18) y siga
todas las instrucciones para hacer todas las conexiones necesar-
ias. Luego vuelva a esta hoja para completar la instalación de este
accesorio.
Faire les raccordements électriques des fils fils conducteurs
d'alimentation du luminaire. Reportez-vous à la fiche d'instruction (IS
18) et suivez toutes les instructions de faire tous les raccordements
nécessaires. Puis revenez consulter cette fiche pour terminer
l'installation de este luminaire.
DRAWING 1 - GLASS INSTALLATION
NOTE: It is recommended for ease of installation that the fixture body be
mounted to the wall prior to installing the glass.
Follow mounting instruction sheet provided.
After fixture body is installed return to this page for glass installation
instructions.
NOTA: Para facilitar la instalación se recomienda montar el cuerpo
de la luminaria en la pared antes de instalar el cristal.
Siga la hoja de instrucciones de montaje suministrada.
Después de instalar el cuerpo de la luminaria, regrese a esta
página para obtener instrucciones sobre la instalación del vidrio.
REMARQUE: Il est recommandé pour faciliter l'installation que le
corps du luminaire soit monté sur le mur avant d'installer le verre.
Suivez les instructions de montage fournies.
Une fois le corps du luminaire installé, retournez à cette page pour
obtenir des instructions sur l'installation du verre.
S
1
2
H
L
M
1. To install glass first thread socket cover (1) from the socket (S) and
remove flat washer (M) - see Drawing 1.
2. Next slip socket (S) through small hole (H) in top of glass (2).
3. Hold glass (2) in place and slip washer (M) over socket and
thread socket cover (1) back onto socket, making sure flat lip (L) of
socket cover is cover is up against wahser.
1. Para instalar la tapa del zócalo de rosca del primer cristal (1)
desde el zócalo (S) y
Quite la arandela plana (M) - vea Dibujo 1.
2. Coloque el siguiente zócalo (S) a través del agujero pequeño
(H) en la parte superior del cristal (2).
3. Sostenga el vaso (2) en su lugar y deslice la arandela (M)
sobre el zócalo y vuelva a colocar la cubierta del zócalo (1) en el
zócalo, asegurándose de que el reborde plano (L) de la cubierta
del zócalo esté en contacto con el wahser.
1. Installer le couvercle de la première douille filetée en verre (1) à
partir de la douille (S) et
Retirer la rondelle plate (M) - voir Dessin 1.
2. Glisser la douille suivante (S) à travers le petit trou (H) en haut
du verre (2).
3. Maintenez le verre (2) en place et la rondelle (M) sur la douille et
(1) sur la douille, en vous assurant que le rebord plat (L) du
couvercle de la douille est contre le wahser.
HH
II
NN
KK
LL
EE
YY
HINKLEY 33000 Pin Oak Parkway, Avon Lake, OH 44012 800.446.5539 / 440.653.5500 hinkley.com
Note: make sure the rubber part of the washer (M) is facing towards
the glass
Nota: asegúrese de que la parte de goma de la arandela (M)
esté orientada hacia el vidrio
Remarque : assurez-vous que la partie en caoutchouc de la
rondelle (M) est tournée vers le verre
start here
commencez ici
empezar aquí
Mounting Instructions
Item No: 2790 / 2794 / 2795
Instructions de montage
Numéro d’article: 2790 / 2794 / 2795
Instrucciones De Montaje
Número del artículo: 2790 / 2794 / 2795
English Spanish French
1. Find a clear area in which you can work.
2. Unpack fixture and glass from carton.
3. Carefully review instructions prior to assembly.
1. Encontrar un área clara en la que se puede trabajar.
2. Desembale xture fi y el vidrio de la caja.
3. Revise cuidadosamente las instrucciones antes del montaje.
1. Trouvez un endroit clair dans lequel vous pouvez travailler.
2. Déballez fi xture et de verre du carton.
3. Examinez attentivement les instructions avant l'assemblage.
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUC-
TIONS (I.S. 18) AND ANY ADDITIONAL DIRECTIONS. TURN
POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS
REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL
AUTHORITIES FOR CODE REQUIREMENTS.
Make electrical connections from supply wire to fixture lead wires.
Refer to instruction sheet (I.S. 18) and follow all instructions to make
all necessary wiring connections. Then refer back to this sheet to
complete installation of this fixture.
ADVERTENCIA DE SEGURIDAD: CABLEADO DE LEER Y
INSTRUCCIONES DE CONEXIÓN A TIERRA (SI 18), E
INSTRUCCIONES ADICIONALES. VUELTA DE ALIMENTACIÓN
DURANTE LA INSTALACIÓN. SI SE REQUIERE UN NUEVO
CABLEADO, CONSULTE A UN ELECTRICISTA O AUTORI-
DADES LOCALES PARA REQUISITOS DEL CÓDIGO.
AVERTISSEMENT DE SÉCURITÉ: CÂBLAGE LIRE ET MISE A LA
TERRE (IS 18) ET TOUTE AUTRE INSTRUCTION. COUPER
L'ALIMENTATION PENDANT L'INSTALLATION. SI DE
NOUVELLES CÂBLAGE NE EST NÉCESSAIRE, CONSULTER UN
ÉLECTRICIEN QUALIFIÉ OU LES AUTORITÉS LOCALES LES
EXIGENCES DES CODES.
Haga las conexiones eléctricas del cable para suministrar cables
conductores de luz. Consulte la hoja de instrucciones (IS 18) y siga
todas las instrucciones para hacer todas las conexiones necesar-
ias. Luego vuelva a esta hoja para completar la instalación de este
accesorio.
Faire les raccordements électriques des fils fils conducteurs
d'alimentation du luminaire. Reportez-vous à la fiche d'instruction (IS
18) et suivez toutes les instructions de faire tous les raccordements
nécessaires. Puis revenez consulter cette fiche pour terminer
l'installation de este luminaire.
Drawing 1 - Fixture Mounting
.
1. Prepare mounting strap (A) by threading the two long mounting screws
(B) into the back of the universal strap - see Drawing 1.
• Be sure the holes into which the screws are threaded match the
spacing of holes (D) in the back plate (E).
2. Attach mounting strap (A) to junction box (J) using two screws (C).
(not provided)
1. To mount fixture, slip the two mounting screws (B) through the two
mounting holes (D) in the backplate (E) - see Drawing 1.
2. While holding fixture in place, thread the two ball knobs (F) on to the
end
of the mounting screws (B), and tighten.
E
B
F
D
C
A
J
1. Prepare la correa de montaje (A) enroscando los dos tornillos
de montaje largos (B) en la parte posterior de la correa
universal - vea Dibujo 1.
Asegúrese de que los orificios en los que están roscados los
tornillos coinciden con la separación de los orificios (D) en la
placa trasera (E).
2. Fije la correa de montaje (A) a la caja de conexiones (J) con
los dos tornillos (C). (no proporcionado)
1. Préparer la sangle de fixation (A) en enfilant les deux vis de
montage longues (B) à l'arrière de la sangle universelle - voir
Dessin 1.
Assurez-vous que les trous dans lesquels les vis sont filetées
correspondent à l'espacement des trous (D) dans la plaque arrière
(E).
2. Fixez la sangle de fixation (A) à la boîte de jonction (J) à l'aide
des deux vis (C). (Non fourni)
1. Para montar el aparato, deslice los dos tornillos de montaje (B)
a través de los dos orificios de montaje (D) en la placa posterior
(E) - vea el Dibujo 1.
2. Mientras sostiene el accesorio en su lugar, enhebre las dos
perillas de bola (F) hasta el extremo
De los tornillos de montaje (B), y apriete.
1. Para montar el aparato, deslice los dos tornillos de montaje (B) a
través de los dos orificios de montaje (D) en la placa posterior (E) -
vea el Dibujo 1.
2. Mientras sostiene el accesorio en su lugar, enhebre las dos
perillas de bola (F) hasta el extremo
De los tornillos de montaje (B), y apriete.
HH
II
NN
KK
LL
EE
YY
HINKLEY 33000 Pin Oak Parkway, Avon Lake, OH 44012 800.446.5539 / 440.653.5500 hinkley.com
I.S. 18 wiring grounding instructions
SAFETY WARNING: READ WIRING AND GROUNDING
INSTRUCTIONS (IS 18) AND ANY ADDITIONAL DIRECTIONS.
TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW
WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR
LOCAL AUTHORITIES FOR CODE REQUIREMENTS
wiring instructions
Indoor Fixtures
1. Connect positive supply wire (A) (typically black or the smooth,
unmarked side of the two-conductor cord) to positive fixture lead (B)
with appropriately sized twist on connector - see Drawings 1 or 2.
2. Connect negative supply wire (C) (typically white or the ribbed, marked
side of the two-conductor cord) to negative fixture lead (D).
3. Please refer to the grounding instructions below to complete all
electrical connections
Outdoor Fixtures
1. Connect positive supply wire (A) (typically black or the smooth
unmarked side of the two-conductor cord) to positive fixture lead (B)
with appropriately sized twist on connector --- see Drawings 2 or 3.
2. Connect negative supply wire (C) (typically white or the ribbed, marked
side of the two-conductor cord) to negative fixture lead (D).
3. Cover open end of connectors with silicone sealant to form a
watertight seal.
If installing a wall mount fixture, use caulk to seal gaps between the
fixture mounting plate (backplate) and the wall. This will help prevent
water from entering the outlet box. If the wall surface is lap siding, use
caulk and a fixture mounting platform specially.
4. Please refer to the grounding instructions below to complete all
electrical connections.
grounding instructions
Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture
ground wire (E) (typically copper or green plastic coated) to the fixture
mounting strap (M) with the ground screw (S) - see Drawing 1.
Note: On straps for screw supported fixtures, first install the two mounting
screws in strap. Any remaining tapped hole may be used for the ground screw.
Chain Hung Fixtures
Loop fixture ground wire (E) (typically copper or green plastic coated)
under the head of the ground screw (S) on fixture mounting strap (M)
and connect to the loose end of the fixture ground wire directly to the
ground wire of the building system with appropriately sized twist-on
connectors - see Drawing 2.
Post-Mount Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated)
to power supply ground with appropriately sized twist-on connector
inside post. Cover open end of connector with silicone sealant to form a
watertight seal - see Drawing 3.
I.S. 18 blage échouage instructions
AVERTISSEMENT DE SECURITE: LIRE CABLAGE ET INSTRUCTIONS DE
MISE (IS 18), ET TOUTE AUTRE INSTRUCTION. COUPER L’ALIMENTATION
ELECTRIQUE PENDANT L’ONSTALLATION. SI DE NOUVELLES CABLAGE
N’EST NECESSAIRE, CONSULTEZ UN ELECTRICIEN QUALIFIE OU
AUTORITES LOCALES POUR EXIGENCES DU CODE.
instructions de câblage
Luminaires Itérieurs
1. Brancher le fil d’alimentation positive (A) (généralement noir ou, té lisse
banalisée de la corde á deux conducteurs) á plob de fixation positive (B) avec
la torsion de taille appropriée sur le connecteur --- Voir Scma 1 ou 2.
2. Connecter le fil d’alimentation négative (C) (généralement blanc ou l’, côté
marqué nervurée du fil á deux conducteurs) au conducteur négatif de
l’appareil (D).
3. S’il vous plaît se rérer á la mise á la terre instructions ci-dessous pour
terminer toutes les connexions électriques.
Luminaires Extérieurs
1. Brancher le fil d’alimentation positive (A) (généralement noir ou le té lisse
banalisée de la corde á deux conducteurs) á plomb dexation positive (B)
avec la torsion approrpriately taille du connecteur --- Voir Schéma 2 ou 3.
2. Connecter le fil d’alimentation négative (C) (généralement blanc ou l’, côté
marqué nervurée du fil á deux conducteurs) au conducteur négatif de
l’appareild (D).
3. Couvrir extrémiouverte de connecteurs acex du silicone pour former un
joint étenche á l’eau.
Si l’installation d’un luminaire de montage mural, utiliser calfeutrage pour
sceller l’espace entre la plaque de montage de xation (plaque arriére) et la
paroi. Cela aidera á empêcher l’eau de pénétrer dans le boc sortie. Si la
surface du mur est bardage á clin, utiliser caldeutrage et une plate-forme de
montage d’appareils spécialement.
4. S’il vous plait se referrer auc instructions ci-dessous pour terminer la terre
toutes les connexions électrques.
instructions de mise
Montage Encastré Fixtures
Pour la terre positive dans un systéme électrique á 3 fils, fixez le fil de terre du
luminaire (E) (généralement en cuivre ou vert recouvert de plastique) á la sangle
dexation dexation (M) avec la vis de terre (S) --- Voir Schéma 1.
Remarque: Sur les sangles pour les appareils pris en charge á vis, installez d’abord les
deux vis de fixation á sangle. Tout trou taraudé restante peut être utilisée pour la vis de
terre.
Chaîne Accroché Luminaires
Boucle fil du luminaire au sol (E) (généralement en cuivre ou vert recouvert de
plastique) sous la te de la vis de terre (S) sur la sangle de xation dexation
(M) et se connecter á l’extrémitré libre du fil de terre du luminaire directement
sur le fil de terre du systéme de construction avec une taille appropriée
connecteurs á visser --- Voir Schéma 2.
Luminaires Aprés Montage
Brancher le fil de terre du luminaire (E) (généralement en cuivre ou vert
recouvert de plastique) á la masse de l’alimentation avec une taille appropriée
torsion sur le connecteur á l’intérieur de la poste. Couvrir extrémité ouverte du
connecteur avec du mastic silicone pour former un joint étache á leau --- Voir
Schéma 3.
I.S. 18 tierra cableado instrucciones
ADVERTENCIA DE SEGURIDAD: LEA LAS INSTRUCCIONES DE CABLEADO
Y LA TIERRA (IS 18), E INSTRUCCIONES ADICIONALES. APAUGE LA
ALIMENTACIÓN DE CORRIENTE DURANTE LA INSTALACIÓN. SI SE
REQUIERE NUEVO CABLEADO, CONSULTE CON UN ELECTRICISTA O
AUTHORIDADES LOCALES PARA REQUISITOS DEL CÓDIGO
Instrucciones de cableado
Acesorios Cubierta
1. Conecte el cable de alimentación positive (A) (normalmente negro o la cara
lisa, sin marcas del cable de dos conductores) de plomo accesorio positivo (B)
con un giro de tamaño adecuado en el conector --- Véase la Figura 1 y 2.
2. Conecte el cable de alimentación negativa (C) (por lo general de color
blanco o el lado marcado estriado del cable de dos conductores) de plomo
accesorio negativo (D).
3. Por favor, consulte las instrucciones de puesta a tierra-a continuación para
completar todas las conexiones eléctricas.
Accesorios Exterior
1. Conecte el cable de alimentación positiva (A) (normalmente negro el lado no
marcado suave del cable de dos conductores) de plomo accesorio positivo (B)
con un giro de tamaño approrpriately conector --- Véase la Figura 2 y 3.
2. Conecte el cable de alimentación negative (C) (por lo general de color
blanco o el lado marcado estriado del cable de dos conductores) de plomo
accesorio negativo (D).
3. Cubra el extreme abierto de conectores con sellador de silicona poara formar
un sello hermético.
Si va a instalar un soporte de fijación mural, use masilla para sella los
espacios entre la placa de montaje del aparato (placa) y la pared. Esto
ayudará a evitar que el agua entre en la boc salida. Si la superficie de la
pared es de revestimiento solapado, utilice masilla y una plataforma de
montaje accesorio especial.
4. Por favor, consulte las Instrucciones de puesta a tierra-a continuación para
completar todas las conexiones eléctricas.
instrucciones puesta a tierra
Montaje Embutido Accesorios
Para conectar a tierra en un sistema eléctrico de 3 hilos, fije el cable de tierra
del artefacto (E) (generalmente de cobre o verde recubierto de plástico) a la
brida de montaje accesorio (M) con el tornillo de tierra (S) --- Véase la Figura 1.
Nota : En las correas de accesorios compatibles tornillos, primero instale los dos
tornillos de montaje de la correa. Cualquier agujero roscado restante puede ser
utilizado para el tornillo de tierra.
Cadena Hung Accesorios
Loop alambre de tierra (E) (generalmente de cobre o verde recubierto de
plático) debajo de la cabeza del tornillo de tierra (S) en la brida de montaje
accesorio (M) y conectar con el extremo suelto del cable de tierra luminaria
directamente al cable de tierra del sistema de construcción con un tamaño
adecuado twist-conectores --- Véase la Figura 2.
Accesorios Posterior Monte
Conecte el cable de tierra del artefacto (E) (generalmente de cobre o verde
recubierto de plástico) a tierra de la fuente de alimentacón con conector de
tamanño adecuado en el interior puesto enlaces en forma. Cubra el extremo
abierto del conector con sellador de silicona para formar un sello hermético ---
Véase la Figura 3.
Drawin
g
1 – Flush Mount
Drawin
g
2 – Chain Hun
g
Drawin
g
3 – Post-Mount
HH
II
NN
KK
LL
EE
YY
HINKLEY 33000 Pin Oak Parkway, Avon Lake, OH 44012 800.446.5539 / 440.653.5500 hinkley.com
IS200 Caulking Instructions
start here
After securing fixture in place it is recommended that the gap between the
mounting top and fixture base be sealed with any good quality waterproof caulk
or silicone sealant (not included). It is also recommended that a small bead of
caulk or sealant be put under the ball knobs used to mount fixture see Drawing
2.
IS200 Instrucciones Calafateo
comience aquí
Aprés avoir assure appareil en placew, il est recommandé que l’écart entre le
sommet et la base de montage du luminaire être scellé avec un produit de
calfeutrage impermeable de bonne qualité ou du mastic silicone (non inclus). Il est
également recommandé qu’un petit cordon de masic d’étanchéité ou être mis sous
les boutons de billes utilisées pour monter appareil – Voir schéma 2.
IS200 Instructions Calfeutrer
commencer ici
Después asegurar fijo en su lugar, se recomienda que la distancia entre la parte
superior y la base de montaje del accesorio se sellará con cualquier buen masilla
impermeable de calidad o sellador de silicona (no incluido). También se
recomienda que una pequeña capa de madilla o selllador de ser sometidos a los
mandos de bolas utilizadas para montar accesorio Véase la Figura 2.
Drawin
g
1 Schéma 1 Fi
g
ura 1
Caulking Gun
Bead of caulk to
seal the gap.
Ball Knob
Caulking
Caulking Gun
Pistolet á
calfeutrer
Produit de
calfeutrafe pour
sceller l’écart
Bolas de
massilla para
sellar la brecha
Pistola para
calafatear
Bouton
de Boule
Perilla de
Bola
Calfeutrage Selladores
Fi
Schéma 2
Drawin
g
2
Pistolet á
calfeutrer
Pistola para
calafatear
Fi
g
ura 2
After securing fixture to the wall it is recommended that the gap between the wall and
the fixture backplate be sealed on the top and both sides, with a good quality
waterproof caulk or silicone sealant (NOT INCLUDED) - see Drawing 1.
Después de asegurar accesorio a la pared, se recomienda que la distancia entre la
pared y la placa posterior fixture ser sellado en la parte superior y ambos lados, con
una buena calidad masilla impermeable o sellador de silicona (NO INCLUIDO)
- ver dibujo 1.
Après avoir obtenu fixation à la paroi, il est recommandé que l'espace entre la paroi
et la contre-plaque de fixation est scellée sur la partie supérieure et deux côtés, avec
une bonne qualité calfeutrage imperméable à l'eau ou silicone (non inclus)
- voir schéma 1.
HH
II
NN
KK
LL
EE
YY
HINKLEY 33000 Pin Oak Parkway, Avon Lake, OH 44012 800.446.5539 / 440.653.5500 hinkley.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Hinkley 2795OZ-CL Manual de usuario

Tipo
Manual de usuario
Este manual también es adecuado para