Leviton W5320-T0G Guía de instalación

Tipo
Guía de instalación

Este manual también es adecuado para

0.500" 1.063" 4.250" 1.063" 0.500"
0.781" 0.781" 4.250" 0.781" 0.781"
0.500"1.625"1.063"1.625"1.031"
SB-201-W5320-20E
PK-98093-40-00-0A
TO INSTALL:
WARNING: TO BE INSTALLED AND/OR
USED IN ACCORDANCE WITH
APPROPRIATE ELECTRICAL CODES
AND REGULATIONS.
WARNING: IF YOU ARE NOT SURE
ABOUT ANY PART OF THESE
INSTRUCTIONS, CONSULT AN
ELECTRICIAN.
FOR SEPARATE FEED CONVERSION
ONLY: Our outlet is provided with a break-
off fin located between the two brass
te rminal screws. If you want to
have the top outlet and the bottom outlet
controlled by two different hot wires
(two circuits), remove the break-off fin
before wiring. With needlenose pliers, bend
fin back and forth until it breaks off.
1. WARNING: TO AVOID FIRE, SHOCK,
OR DEATH; TURN OFF POWER AT
CIRCUIT BREAKER OR FUSE AND
TEST THAT THE POWER IS OFF
BEFORE WIRING!
2. Remove insulation per strip gauge on
device [about 5/8” (1.6 cm)].
3. Connect wires per WIRING DIAGRAM
as follows:
To Side Wire: Loop wires clockwise 3/4
turn around terminal screws. BLACK (hot)
wire to BRASS screw, WHITE (neutral)
wire to SILVER screw, GREEN or BARE
(ground) wire to GREEN screw. Firmly
tighten screws over wire loops. Terminal
screws accept up to #12 AWG copper or
copper clad wire.
To Quickwire
TM
: Insert straight #14 AWG
solid copper or copper clad wires into
round Quickwire
TM
holes. Quickwire
TM
terminals accept #14 AWG solid copper
or copper clad wires ONLY! For circuits
with #12 AWG solid copper or copper
clad wires, use side wiring devices
instead. If the receptacle must be
replaced or rewired after Quickwiring,
gently press the tip of a small screwdriver
in the release slot and back the wire out
gradually.
4. Mount device using long mounting
screws. Attach wallplate (not included).
5. Restore power at circuit breaker or fuse.
Installation is complete.
TO INSTALL: WEATHER & TAMPER RESISTANT RECEPTACLE - Rated: 15A-125V
INSTALLATION : PRISE DOBLE INTEMPERISE / INVIOLABLE - Valeurs nominales : 15A,125V
PARA INSTALAR: RECEPTÁCULO RESISTENTE A LA INTERPERIE / INTROMISION - Capacidad: 15A-125V
INSTALLATION :
AVERTISSEMENT :
INSTALLER OU
UTILISER CONFORMÉMENT
AUX CODES DE L’ÉLECTRICITÉ EN
VIGUEUR.
AVERTISSEMENT : À DÉFAUT DE BIEN
COMPRENDRE LES DIRECTIVES
SUIVANTES, FAIRE APPEL À UN
ÉLECTRICIEN.
ALIMENTATION SÉPARÉE SEULEMENT
: la prise est dotée d’une ailette
détachable entre ses deux bornes
laitonnées. Si on veut que les sorties
supérieure et inférieure soient alimentées
par deux fils actifs distincts (deux circuits),
cette ailette doit être retirée avant qu’on
procède au câblage. Le cas échéant, se
servir d’une pince à bec effilé pour la plier
et la replier jusqu’à ce qu’elle casse.
1.
AVERTISSEMENT : POUR ÉVITER
LES RISQUES D’INCENDIE, DE CHOC
ÉLECTRIQUE OU DE BLESSURE
MORTELLE, COUPER LE COURANT
AU FUSIBLE OU AU DISJONCTEUR
ET S’ASSURER QUE LE CIRCUIT SOIT
BIEN COUPÉ AVANT DE PROCÉDER À
L’INSTALLATION.
2. Dénuder les fils conformément au gabarit
apparaissant sur le dispositif (environ
1,6 cm).
3. Raccorder les fils conformément au
SCHÉMA DE CÂBLAGE, de la façon
suivante :
Câblage latéral : enrouler de 3/4 de tour
les fils sur les bornes à vis. Raccorder
le fil NOIR (actif) à la vis LAITON, le fil
BLANC (neutre) à la vis ARGENT; le
fil VERT ou DÉNUDÉ (MALT) à la vis
VERTE. Serrer ces dernières fermement.
Les bornes à vis acceptent les fils de
cuivre de calibre allant jusqu’ à 12 AWG.
Câblage rapide (Quickwire
MC
) : raidir et
insérer les fils dans les orifices de câblage
rapide. Les bornes Quickwire
MC
acceptent
les fils en cuivre plein ou plaqués cuivre
de calibre 14 AWG SEULEMENT! En
présence de fils de cuivre ou plaqués
cuivre d’un calibre de 12 AWG, se servir
plutôt des raccords latéraux. Si la prise
doit être remplacée ou recâblée, appuyer
délicatement la pointe d’un petit tournevis
sur la patte de dégagement et retirer
graduellement les fils.
4.
Installer le dispositif au moyen de longues
vis de fixation. Fixer la plaque murale.
5. Rétablir le courant au fusible ou au
disjoncteur. L’installation est terminée.
PARA INSTALAR:
ADVERTENCIA: PARA INSTALARSE
Y/O USARSE DE ACUERDO CON LOS
CODIGOS ELECTRICOS Y NORMAS
APROPIADAS.
ADVERTENCIA: SI USTED NO ESTA
SEGURO ACERCA DE ALGUNA
DE LAS PARTES DE ESTAS
INSTRUCCIONES, CONSULTE A UN
ELECTRICISTA.
SOLO PARA ALIMENTACION
SEPARADA: Este contactotiene una
aleta rompible ubicada entre las dos
terminales de latón. Si quiere que el
contacto de arriba y el contacto de
abajo se controlen con 2 alambres fase
diferentes (dos circuitos), rompa la aleta
antes de la instalación. Con un alicate de
punta, doble hacia atrás y adelante hasta
que se rompa.
1.
ADVERTENCIA: PARA EVITAR
DESCARGA ELECTRICA, FUEGO O
MUERTE, INTERRUMPA EL PASO DE
ENERGIA MEDIANTE EL INTERRUPTOR
DE CIRCUITO O FUSIBLE. ¡ASEGURESE
QUE EL CIRCUITO NO ESTE
ENERGIZADO ANTES DE INICIAR LA
INSTALACION!
2. Pele los cables según la medida dibujada
detrás del producto (aprox. 1.6 cm).
3. Conecte los cables según el DIAGRAMA
DE CABLEADO y como sigue:
Para Cableado Lateral: Enrosque los
alambres 3/4 de vuelta hacia la derecha
alrededor de los tornillos terminales.
El cable NEGRO (fase) al tornillo color
LATON, el cable BLANCO (neutro) al
tornillo color PLATEADO, el VERDE o
PELADO (a tierra) al tornillo VERDE.
Apriete los tornillos sobre el alambre en
roscado. Los tornillos terminales aceptan
cable de cobre o revestido de cobre
hasta #12 AWG.
Para Quickwire
MR
(Cableado Rápido):
Inserte los alambres de cobre o revestido
de cobre # 14 AWG en los orificios
redondos Quickwire
MR
. Las terminales
Quickwire
MR
SOLO aceptan cable de
cobre o revestido de cobre # 14 AWG.
Para los circuitos con cable de cobre o
revestido de cobre # 12 AWG, use los
lados del producto. Si tiene que remplazar
el receptáculo o rehacer el cableado
después de haber instalado terminales
Quickwire, apoye suavemente la punta de
un destornillador pequeño en la ranura de
liberación y libere el cable gradualmente.
4. Monte el producto con los tornillos largos
provistos. Ponga la placa mural.
5. Restablezca la corriente con el fusible o
interruptor de circuitos. La instalación
está completa.
WARNING: USE THIS DEVICE WITH COPPER OR COPPER-CLAD WIRE ONLY.
AVERTISSEMENT : N’UTILISER CE DISPOSITIF QU’AVEC DU FIL DE CUIVRE OU PLAQUÉ CUIVRE.
ADVERTENCIA: USE ESTE PRODUCTO SOLO CON CABLE DE COBRE O REVESTIDO DE COBRE.
DIRECTIONS FOR BREAKING OFF TERMINAL FIN
DIRECTIVES POUR PARER L’AILETTE DÉTACHABLE
DIRECCIONES PARA ROMPER LA ALETA TERMINAL
Wiring Diagram / Schéma de câblage / Diagrama de alambrad
o
Neutral (White)
Neutre (Blanc)
Neutro (Blanco)
Break-off fin
L’ailette détachable
Aleta rompible
Hot (Black)
Actif (Noir)
Fase (Negro)
Green Ground
Terre vert
Verde a tierra

Transcripción de documentos

0.500" 1.063" 4.250" 0.500" TO INSTALL: WARNING: TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND REGULATIONS. WARNING: IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT AN ELECTRICIAN. FOR SEPARATE FEED CONVERSION ONLY: Our outlet is provided with a breakoff fin located between the two brass te­rminal screws. If you want to have the top outlet and the bottom outlet controlled by two different hot wires (two circuits), remove the break-off fin before wiring. With needlenose pliers, bend fin back and forth until it breaks off. 1. WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING! 2. Remove insulation per strip gauge on device [about 5/8” (1.6 cm)]. 3. Connect wires per WIRING DIAGRAM as follows: To Side Wire: Loop wires clockwise 3/4 turn around terminal screws. BLACK (hot) wire to BRASS screw, WHITE (neutral) wire to SILVER screw, GREEN or BARE (ground) wire to GREEN screw. Firmly tighten screws over wire loops. Terminal screws accept up to #12 AWG copper or copper clad wire. To QuickwireTM: Insert straight #14 AWG solid copper or copper clad wires into round QuickwireTM holes. QuickwireTM terminals accept #14 AWG solid copper or copper clad wires ONLY! For circuits with #12 AWG solid copper or copper clad wires, use side wiring devices instead. If the receptacle must be replaced or rewired after Quickwiring, gently press the tip of a small screwdriver in the release slot and back the wire out gradually. 4. Mount device using long mounting screws. Attach wallplate (not included). 5. Restore power at circuit breaker or fuse. Installation is complete. INSTALLATION : PRISE DOBLE INTEMPERISE / INVIOLABLE - Valeurs nominales : 15A,125V INSTALLATION : AVERTISSEMENT : INSTALLER OU UTILISER CONFORMÉMENT AUX CODES DE L’ÉLECTRICITÉ EN VIGUEUR. AVERTISSEMENT : À DÉFAUT DE BIEN COMPRENDRE LES DIRECTIVES SUIVANTES, FAIRE APPEL À UN ÉLECTRICIEN. ALIMENTATION SÉPARÉE SEULEMENT : la prise est dotée d’une ailette détachable entre ses deux bornes laitonnées. Si on veut que les sorties supérieure et inférieure soient alimentées par deux fils actifs distincts (deux circuits), cette ailette doit être retirée avant qu’on procède au câblage. Le cas échéant, se servir d’une pince à bec effilé pour la plier et la replier jusqu’à ce qu’elle casse. 1. A  VERTISSEMENT : POUR ÉVITER LES RISQUES D’INCENDIE, DE CHOC ÉLECTRIQUE OU DE BLESSURE MORTELLE, COUPER LE COURANT AU FUSIBLE OU AU DISJONCTEUR ET S’ASSURER QUE LE CIRCUIT SOIT BIEN COUPÉ AVANT DE PROCÉDER À L’INSTALLATION. 2. Dénuder les fils conformément au gabarit apparaissant sur le dispositif (environ 1,6 cm). 3. R  accorder les fils conformément au SCHÉMA DE CÂBLAGE, de la façon suivante : Câblage latéral : enrouler de 3/4 de tour les fils sur les bornes à vis. Raccorder le fil NOIR (actif) à la vis LAITON, le fil BLANC (neutre) à la vis ARGENT; le fil VERT ou DÉNUDÉ (MALT) à la vis VERTE. Serrer ces dernières fermement. Les bornes à vis acceptent les fils de cuivre de calibre allant jusqu’ à 12 AWG. Câblage rapide (QuickwireMC) : raidir et insérer les fils dans les orifices de câblage rapide. Les bornes QuickwireMC acceptent les fils en cuivre plein ou plaqués cuivre de calibre 14 AWG SEULEMENT! En présence de fils de cuivre ou plaqués cuivre d’un calibre de 12 AWG, se servir plutôt des raccords latéraux. Si la prise doit être remplacée ou recâblée, appuyer délicatement la pointe d’un petit tournevis sur la patte de dégagement et retirer graduellement les fils. 4. Installer le dispositif au moyen de longues vis de fixation. Fixer la plaque murale. 5. Rétablir le courant au fusible ou au disjoncteur. L’installation est terminée. DIRECTIONS FOR BREAKING OFF TERMINAL FIN DIRECTIVES POUR SÉPARER L’AILETTE DÉTACHABLE DIRECCIONES PARA ROMPER LA ALETA TERMINAL Hot (Black) Actif (Noir) Fase (Negro) Green Ground Terre vert Verde a tierra Break-off fin L’ailette détachable Aleta rompible TO INSTALL: WEATHER & TAMPER RESISTANT RECEPTACLE - Rated: 15A-125V Neutral (White) Neutre (Blanc) Neutro (Blanco) Wiring Diagram / Schéma de câblage / Diagrama de alambrado SB-201-W5320-20E PK-98093-40-00-0A 0.500" WARNING: USE THIS DEVICE WITH COPPER OR COPPER-CLAD WIRE ONLY. AVERTISSEMENT : N’UTILISER CE DISPOSITIF QU’AVEC DU FIL DE CUIVRE OU PLAQUÉ CUIVRE. ADVERTENCIA: USE ESTE PRODUCTO SOLO CON CABLE DE COBRE O REVESTIDO DE COBRE. 1.063" 1.625" 1.063" PARA INSTALAR: RECEPTÁCULO RESISTENTE A LA INTERPERIE / INTROMISION - Capacidad: 15A-125V 1.031" 1.625" PARA INSTALAR: ADVERTENCIA: PARA INSTALARSE Y/O USARSE DE ACUERDO CON LOS CODIGOS ELECTRICOS Y NORMAS APROPIADAS. ADVERTENCIA: SI USTED NO ESTA SEGURO ACERCA DE ALGUNA DE LAS PARTES DE ESTAS INSTRUCCIONES, CONSULTE A UN ELECTRICISTA. SOLO PARA ALIMENTACION SEPARADA: Este contactotiene una aleta rompible ubicada entre las dos terminales de latón. Si quiere que el contacto de arriba y el contacto de abajo se controlen con 2 alambres fase diferentes (dos circuitos), rompa la aleta antes de la instalación. Con un alicate de punta, doble hacia atrás y adelante hasta que se rompa. 1. A  DVERTENCIA: PARA EVITAR 0.781" 0.781" DESCARGA ELECTRICA, FUEGO O MUERTE, INTERRUMPA EL PASO DE ENERGIA MEDIANTE EL INTERRUPTOR DE CIRCUITO O FUSIBLE. ¡ASEGURESE QUE EL CIRCUITO NO ESTE ENERGIZADO ANTES DE INICIAR LA INSTALACION! 2. Pele los cables según la medida dibujada detrás del producto (aprox. 1.6 cm). 3. Conecte los cables según el DIAGRAMA DE CABLEADO y como sigue: Para Cableado Lateral: Enrosque los alambres 3/4 de vuelta hacia la derecha alrededor de los tornillos terminales. El cable NEGRO (fase) al tornillo color LATON, el cable BLANCO (neutro) al tornillo color PLATEADO, el VERDE o PELADO (a tierra) al tornillo VERDE. Apriete los tornillos sobre el alambre en roscado. Los tornillos terminales aceptan cable de cobre o revestido de cobre 4.250" hasta #12 AWG. Para QuickwireMR (Cableado Rápido): Inserte los alambres de cobre o revestido de cobre # 14 AWG en los orificios redondos QuickwireMR. Las terminales QuickwireMR SOLO aceptan cable de cobre o revestido de cobre # 14 AWG. Para los circuitos con cable de cobre o revestido de cobre # 12 AWG, use los lados del producto. Si tiene que remplazar el receptáculo o rehacer el cableado después de haber instalado terminales Quickwire, apoye suavemente la punta de un destornillador pequeño en la ranura de liberación y libere el cable gradualmente. 4. Monte el producto con los tornillos largos provistos. Ponga la placa mural. 5. Restablezca la corriente con el fusible o interruptor de circuitos. La instalación está completa. 0.781" 0.781"