Westinghouse 7840900 Instrucciones de operación

Categoría
Ventiladores domésticos
Tipo
Instrucciones de operación
ETL-ES-Jax(J hook)-WH22
OWNER'S MANUAL
MANUAL DEL USUARIO
Please write model number here for future reference: /
Por favor, incluya el número del modelo aquí para futura referencia:
Net Weight: 13.40 LBS
Peso Neto: 6.09 KGS
Jax
2
ETL-ES-Jax(J hook)-WH22
1. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards (ANSI/NFPA 70), including fire-rated construction.
2. Use this unit only in the manner intended by the manufacturer. If you have any questions contact the manufacturer.
3. After making the wire connections, gently push connections into outlet box with wire nuts pointing up. The wires should be spread apart with the grounded conductor and the equipment-grounding conductor on
one side of the outlet box and ungrounded conductor on the other side of the outlet box.
4. Before you begin installing the fan, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be
locked, securely fasten a prominent warning device, such as a tag, to the service panel.
5. Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.
6. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
7. Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade.
8. To reduce the risk of fire, electric shock, or personal injury, this fan must be mounted to an outlet box marked suitable for fan support, and use the mounting screws provided with the outlet box. (Mounting must
support at least 35 lbs.)
9. WARNING! Do not bend blade holders during installation to motor, balancing or during cleaning. Do not insert foreign object between rotating blades.
10. Attach the mounting bracket using only the hardware supplied with the outlet box. Fan is only to be mounted to an outlet box marked Acceptable for Fan Support”.
11. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.
12. NEVER place a switch where it can be reached from a tub or shower.
13. The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment manufacturer’s guideline safety standards such as those
published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
14. Before servicing or cleaning unit, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be
locked, securely fasten a prominent warning device, such as a tag, to the service panel.
15. All set screws must be checked and re-tightened where necessary before installation.
16. The appliance is not intended for use by young children or infirmed persons without supervision. Young children should be supervised to ensure they do not play with the appliance.
TOOLS REQUIRED
Phillips Screwdriver Wire Cutters Pliers Step Ladder
SAFETY TIPS
OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR PERSONAL INJURY, MOUNT TO OUTLET BOX MARKED 'ACCEPTABLE FOR FAN SUPPORT OF 35 LBS (15.9 KG) OR LESS'
AND USE MOUNTING SCREWS PROVIDED WITH THE OUTLET BOX AND/OR SUPPORT DIRECTLY FROM BUILDING STRUCTURE. MOST OUTLET BOXES COMMONLY USED FOR THE
SUPPORT OF LUMINARIES ARE NOT ACCEPTABLE FOR FAN SUPPORT AND MAY NEED TO BE REPLACED. CONSULT A QUALIFIED ELECTRICIAN IF IN DOUBT.
3
ETL-ES-Jax(J hook)-WH22
1. El trabajo de instalación y el cableado eléctrico los deben efectuar personas calificadas cumpliendo con todos los códigos y las normas aplicables (ANSI/NFPA 70), incluyendo las de incendio.
2. Use esta unidad sólo de la manera en que el fabricante quiere que se haga. Si tiene dudas, llame al fabricante.
3. Después de hacer las conexiones, empuje con cuidado las conexiones dentro de la caja de embutir con los conectores de cables mirando hacia arriba. Se deben separar los cables: el conductor de puesta a tierra y el conductor
de puesta a tierra del equipo a un lado de la caja de embutir, y el conductor que no tiene puesta a tierra del otro lado de la misma.
4. Antes de comenzar a instalar el ventilador, apague la alimentación en el panel de servicio y bloquee el medio de desconexión del servicio para evitar que se encienda accidentalmente. Cuando no se puede bloquear el medio
de desconexión del servicio eléctrico, fije de manera segura un dispositivo de advertencia prominente, como un rótulo, al panel de servicio.
5. ¡Tenga cuidado! Lea todas las instrucciones y la información de seguridad antes de instalar su ventilador nuevo. Revise los diagramas de montaje incluidos.
6. Al cortar o perforar una pared o techo, no dañe el cableado eléctrico y otras instalaciones de servicios públicos ocultos.
7. Asegúrese de que el sitio para la instalación que escoja permita que el ventilador gire libremente sin obstrucciones. Deje un espacio mínimo de 7 pies desde le piso hasta el borde posterior de la aleta.
8. Para reducir el riesgo de incendios, choques eléctricos o heridas personales, este ventilador se debe montar sobre una caja de embutir que tenga una marca que indique que es adecuada para soportar un ventilador.
Además debe utilizar los tornillos correspondientes incluidos con la caja de embutir. (El montaje debe soportar por lo menos 35 lbs. (15.9 kgs.).
9. ¡ADVERTENCIA! No doble los soportes para las aletas durante la instalación al motor, al balancear o durante la limpieza. No inserte objetos extraños entre las aletas mientras giran.
10. Fije el soporte de montaje usando sólo la tornillería suministrada con la caja de embutir. El ventilador sólo se debe montar en una caja de embutir marcada Acceptable for Fan Support” (Aceptable para soportar ventiladores).
11. Si esta unidad se instalará sobre una bañera o una ducha, debe estar identificada como adecuada para ese tipo de aplicación.
12. NUNCA coloque un interruptor donde se pueda alcanzar desde una bañera o una ducha.
13. Es posible que la operación de esta unidad afecte el flujo de aire de combustión necesario para la operación segura de equipo que quema combustible. Siga la directrices de seguridad del fabricante de equipo de calefacción
como las publicadas por la Asociación Nacional de Protección Contra Incendios (National Fire Protection Association, NFPA), y la Sociedad Americana para Ingenieros de Calefacción, Refrigeración y Aire Acondicionado
(American Society for Heating, Refrigeration and Air Conditioning Engineers, ASHRAE) y las autoridades del código local.
14. Antes de efectuar tareas de servicio o limpieza en la unidad, apague la alimentación en el panel de servicio y bloquee el medio de desconexión del servicio para evitar que se encienda accidentalmente. Cuando no se puede
bloquear el medio de desconexión del servicio eléctrico, fije de manera segura y un dispositivo de advertencia prominente, como un rótulo, al panel de servicio.
15. Antes de realizar la instalación, es importante comprobar y volver a ajustar todos los tornillos, según corresponda.
16. El dispositivo no ha sido diseñador para ser utilizado por niños o personas enfermas sin supervisión. Los niños deben ser supervisados para asegurarse de que no juegan con el dispositivo.
HERRAMIENTAS NECESARIAS
Destornillador Phillips Pinzas de corte Pinzas Escalera de mano
CONSEJOS DE SEGURIDAD
HAGA LO SIGUIENTE: LEA Y GUARDE ESTAS INSTRUCCIONES
ADVERTENCIA: PARA REDUCIR EL RIESGO DE INCENDIO, DESCARGA ELÉCTRICA O HERIDAS PERSONALES, MONTE EN UNA CAJA DE EMBUTIR ROTULADA ADECUADA PARA VENTILADORES DE 35 LB (15,9 KGS )
O MENOS” UTILIZANDO LOS TORNILLOS DE MONTAJE INCLUIDOS CON LA CAJA DE EMBUTIR Y/O MONTE DIRECTAMENTE EN LA ESTRUCTURA DEL EDIFICIO. LA MAYORÍA DE LAS CAJAS DE EMBUTIR UTILIZADAS
NORMALMENTE CON ARTEFACTOS DE ILUMINACIÓN NO SON ADECUADAS PARA VENTILADORES Y DEBERÍAN SER REEMPLAZADAS. SI TIENE PREGUNTAS, CONSULTE A UN ELECTRICISTA CALIFICADO.
4
ETL-ES-Jax(J hook)-WH22
Unpack and inspect fan carefully to be certain all contents are included.
Turn off power at fuse box to avoid possible electrical shock.
1
Use metal outlet box suitable for fan support (must support 35 lbs).
Before attaching fan to outlet box, ensure the outlet box is securely
fastened by at least two points to a structural ceiling member (a loose
box will cause the fan to wobble).
2
PREPARING FOR INSTALLATION
ANTES DE LA INSTALACIÓN
Quite el envoltorio e inspeccione detenidamente el ventilador para verificar
que todas las piezas estén incluidas. Apague la alimentación en la caja de
fusibles para evitar la posibilidad de descarga eléctrica.
Use una caja de embutir de metal adecuada para soportar un ventilador
(debe soportar 35 libras). Antes de fijar el ventilador a la caja de embutir
asegúrese de que la misma esté fijada de manera segura en por lo menos
dos puntos a un miembro estructural del techo (una caja suelta haría
que el ventilador oscile).
5
MOUNTING BRACKET INSTALLATION
INSTALACIÓN CON SOPORTE DE MONTAJE
Install J” hook mounting plate to outlet box in ceiling using the screws provided with the outlet box.
3
Instale la placa de montaje del gancho J” a la caja de embutir del techo con la tornillería suministrada para la caja de embutir.
ETL-ES-Jax(J hook)-WH22
6
ETL-ES-Jax(J hook)-WH22
MOUNTING
MONTAJE
5
Hang fan on “J” hook. With bracket holding fan assembly, make electrical connec-
tions using the following step for wiring instructions.
Cuelgue el ventilador del gancho J”. Con la pieza de montaje sujetando el
conjunto del ventilador, haga las conexiones eléctricas de acuerdo a las siguientes
instrucciones de cableado.
Align the reverse switch on the yoke to the reverse switch hole in the lower canopy.
Slide the lower canopy down, make sure there is at least 1/4” clearance maintained
between the motor and lower canopy bottom and position the reverse switch prop-
erly. Tighten set screw in the lower canopy.
4
Alinee el interruptor de marcha atrás de la horquilla al agujero para el interruptor de marcha
atrás correspondiente ubicado en el dosel inferior. Deslice el dosel inferior hacia abajo,
asegúrese de mantener un espacio de 1/4 plug (6,4mm) entre el motor y la parte inferior
del dosel inferior y luego posicione el interruptor de marcha atrás de forma apropiada.
Ajuste el(los) tornillo(s) de fijación en el dosel inferior.
7
ETL-ES-Jax(J hook)-WH22
WIRING OPTIONS
OPCIÓN DE CABLEADO
6
AC IN L
AC IN N
Green Ground
To Motor
Black (hot)
Green Ground
White (neutral)
Black
Black
AC IN L
Green Ground
Wall Control
AC Power
Supply
Follow diagram above to make wiring connections for wall control operation.
WALL CONTROL WIRING OPTION
Fuente de
alimentación
de CA
Control de
Pared
Entrada C.A. L
Entrada C.A. N
Verde (de tierra)
Al Motor
Negro (vivo)
Verde (de tierra)
Blanco (neutro)
Negro
Negro
Entrada C.A. L
Verde (de tierra)
Siga las instrucciones del diagrama anterior para hacer las conexiones de
cableado para el ventilador con control de pared.
OPCIÓN DE CABLEADO PARA CONTROL DE PARED
7
MOUNTING
MONTAJE
After wiring is complete, gently push wires into junction box with wire nuts
pointed upward.
Una vez que el cableado esté completo, empuje con cuidado los cables den-
tro de la caja de embutir con los conectores de tuerca mirando hacia arriba.
ETL-ES-Jax(J hook)-WH22
8
BLADE INSTALLATION
INSTALACIÓN DE LAS ALETAS
3
Install blades to top of motor using screws and washers . See above
drawing for reference.
9
Instale las aletas en la parte superior del motor con la tornillería. Utilice la
ilustración anterior como referencia.
SECURE TO CEILING
ASEGURE EL VENTILADOR AL TECHO
3
Slide top canopy up and tighten set screw(s).
8
Deslice el dosel superior y ajuste el(los) tornillo(s) de fijación.
9
ETL-ES-Jax(J hook)-WH22
INSTALLING AND WIRING THE WALL CONTROL
INSTALACIÓN Y CABLEADO DEL CONTROL DE PARED
0
0
1
5
5
4
4
3
3
2
2
1
Parts: 1. Outlet box
2. Cross Bar Screws
3. Cross Bar
4. Outlet Box Screws
5. Control Unit
6. Front Panel
7. Front Panel Screw
8. Terminal Box
9. Terminal Box Screw
10. Black Supply Lead Wire
11. Black Fan Lead Wire
12. Ground Lead Wire
Piezas: 1. Caja de embutir
2. Tornillos de la barra transversal
3. Barra transversal
4. Tornillos de la caja de embutir
5. Unidad de control
6. Panel delantero
7. Tornillo del panel delantero
8. Caja de terminales
9. Tornillo de la caja de terminales
10. Cable guía negro de alimentación
11. Cable guía negro del ventilador
12. Cable guía a tierra
12
3
456
9
7
8
10
12
11
10
ETL-ES-Jax(J hook)-WH22
Installing and wiring the wall control.
A. Remove the cross bar screws (2) from the wall control and attach the cross bar (3) to the outlet box.
B. Remove front panel screw (7). Save for use in step E. Remove front cover (6). WARNING: PLEASE USE CAUTION WHEN REMOVING THE FACE PLATE COVER.
C. Connect black supply lead (10) to A position, black fan lead wire (11) to “F” position on the terminal box (8), and tighten terminal box screw (9).
D. Re-attach wall control to cross bar (3).
E. Slide front cover (6) over wall control and secure with front panel screw (from step B).
Instalación y cableado del control de pared.
A. Quite los tornillos de la barra transversal (2) del control de pared y fije la barra transversal (3) a la caja de embutir.
B. Quite el tornillo del panel delantero (7). Lo necesitará en el paso E. Quite la cubierta delantera (6). ADVERTENCIA: TENGA MUCHO CUIDADO AL QUITAR LA
CUBIERTA DE LA PLACA DELANTERA.
C. Conecte el cable guía negro de alimentación (10) en la posición A, el cable guía negro del ventilador (11) en la posición “F” en la caja de terminales (8), y
ajuste el tornillo de la caja de terminales (9).
D. Una nuevamente el control de pared a la barra transversal (3).
E. Deslice la cubierta delantera (6) sobre el control de pared y asegúrelo con el tornillo del panel delantero (del paso B).
INSTALLING AND WIRING THE WALL CONTROL
INSTALACIÓN Y CABLEADO DEL CONTROL DE PARED
10
11
ETL-ES-Jax(J hook)-WH22
Operation
Turn on the power and check operation of fan. The wall control controls the fan speeds as follows: 1 - low; 2 - medium low; 3 - medium; 4 - medium high; 5 - high; 0 - off.
Speed settings for warm or cool weather depend on factors such as room size, ceiling height, number of fans and so on.
Speed settings for warm or cool weather depend on factors such as room size, ceiling height, number of fans and so on. The slide switch controls direction, forward or reverse.
Warm weather/down position - (Forward) Fan turns counterclockwise direction. A downward air flow creates a cooling effect as shown in illustration A. This allows you to set
your air conditioner on a higher temperature setting without affecting your comfort.
Cool weather/up position - (Reverse) Fan turns clockwise direction. An upward airflow moves warm air off the ceiling area as shown in illustration B. This allows you to set your
heating unit on a lower setting without affecting your comfort.
NOTE: Turn off and wait for fan to stop before changing the setting of the forward/reverse slide switch.
Maintenance
1. Because of the fans natural movement, some connections may become loose. Check the support connections, brackets, and blade attachments twice a year. Make sure they are secure.
2. Clean your fan periodically to help maintain its new appearance over the years. Do not use water when cleaning. This could damage the motor, or the wood, or possibly cause electrical
shock.
3. Use only a soft brush or lint-free cloth to avoid scratching the finish. The plating is sealed with a lacquer coating to minimize discoloration or tarnishing.
4. There is no need to oil your fan. The motor has permanently lubricated bearings.
OPERATION AND MAINTENANCE
12
ETL-ES-Jax(J hook)-WH22
OPERACIÓN Y MANTENIMIENTO
Operación
Encienda el ventilador y verifique su funcionamiento. El control de pared controla las velocidades del ventilador de la siguiente manera: 1 – baja, 2–mediana baja, 3–mediana,
4 – mediana alta, 5 – alta, 0 – apagado. Las velocidades para clima cálido o frío dependen de factores como el tamaño de la habitación, la altura del ventilador, el número de
ventiladores, etc.
Las velocidades para clima cálido o frío dependen de factores como el tamaño de la habitación, la altura del ventilador, el número de ventiladores, etc.
El conmutador de tipo deslizante controla la dirección, hacia adelante o hacia atrás.
Clima cálido/posición hacia abajo - (Adelante) El ventilador gira en sentido contrahorario. Una corriente de aire descendente crea un efecto refrescante como lo indica la ilustración A.
Esto le permite ajustar el aire acondicionado a una temperatura más alta sin que afecte su comodidad.
Clima frío/posición hacia arriba - (Atrás) El ventilador gira en sentido de las agujas del reloj. Una corriente de aire ascendente aleja el aire caliente del área del ventilador de techo
como lo indica la ilustración B. Esto le permite ajustar la calefacción a un nivel más bajo sin que afecte su comodidad.
NOTA: Apague el ventilador y espere a que se detenga antes de cambiar la dirección de adelante/atrás con el conmutador de tipo deslizante.
Mantenimiento
1. El movimiento natural del ventilador podría hacer que se aflojen algunas conexiones. Verifique las conexiones de soporte, las piezas de fijación y los accesorios de las aletas dos
veces al año. Verifique que estén aseguradas.
2. Limpie el ventilador periódicamente para ayudar a mantener su apariencia nueva con el correr de los años. No use agua para limpiarlo, ya que podría dañar el motor o causar
descarga eléctrica.
3. Use sólo un cepillo blando o un trapo sin pelusa para no rayar el acabado. El enchapado está sellado con una capa de laca para minimizar la decoloración o pérdida del brillo.
4. No hay necesidad de aceitar el ventilador. El motor tiene cojinetes de lubricación permanente.
13
ETL-ES-Jax(J hook)-WH22
TROUBLESHOOTING GUIDE If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation, or wiring. In some cases, these
installation errors may be mistaken for defects. If you experience any faults, please check this Trouble Shooting Chart. If a problem cannot
be remedied, please consult with a qualified electrician and do not attempt any electrical repairs yourself.
TROUBLE
1. If fan does not start:
2. If fan sounds noisy:
3. If fan wobbles:
SUGGESTED REMEDY
1. Check main and branch circuit fuses or circuit breakers.
2. Check wire connections as performed in step #6 or #10 of installation. CAUTION: Make sure main power is turned off.
3. If the fan still will not start, contact a qualified electrician. Do not attempt to troubleshoot internal electrical connections yourself.
1. Check to make sure all screws in motor housing are snug (not over tightened).
2. Check to make sure the screws which attach the fan blade to the motor are tight.
3. Some fan motors are sensitive to signals from Solid State variable speed controls. DO NOT USE a Solid State variable speed control.
4. Allow “break-in period of 24 hours. Most noises associated with a new fan will disappear after this period.
All blades are weighed and grouped by weight.
The following procedures should eliminate most of the wobble. Check for wobble after each step.
1. Check that all blade are tightened securely to motor.
2. Make sure that canopy and mounting bracket are tightened securely to a fan rated electrical box or a ceiling joist.
3. If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can redistribute the weight and possibly result in smoother operation.
14
ETL-ES-Jax(J hook)-WH22
GUÍA PARA SOLUCIONAR PROBLEMAS
Si tiene dificultades para hacer funcionar su nuevo ventilador, podría ser a causa del armado, instalación o
cableado incorrectos. En algunos casos, estos errores de instalación podrían ser confundidos con defectos. Si
experiencia alguna falla, consulte esta guía para solucionar problemas. Si no puede solucionar el problema,
consulte a un electricista calificado y no intente reparar conexiones eléctricas.
PROBLEMA
1. Si el ventilador no arranca:
2. Si el ventilador es ruidoso:
3. Si el ventilador oscila:
SOLUCIÓN SUGERIDA
1. Compruebe los fusibles o disyuntores principales y del circuito derivado.
2. Compruebe el cableado del bloque de terminales como lo hizo en el paso No. 6 o 10 de la instalación. ADVERTENCIA: Asegúrese de que la alimentación principal esté apagada.
3. Si el ventilador no arranca, póngase en contacto con un electricista calificado. No intente reparar conexiones eléctricas internas.
1. Compruebe para asegurarse de que todos los tornillos del alojamiento del motor estén ajustados (no los apriete demasiado).
2. Compruebe para asegurarse de que los tornillos que fijan el soporte de la aleta del ventilador al motor estén apretados.
3. Algunos motores de ventilador son sensibles a las señales de los controles de velocidad variable de estado sólido para motores.
NO USE un control de velocidad variable de estado sólido.
4. Permita el "rodaje" del ventilador durante un período de 24 horas. La mayoría de los ruidos asociados con el ventilador nuevo desaparecerán después de este período.
Todas las aletas se pesan y agrupan según el peso.
Los siguientes procedimientos deberían eliminar la mayoría de los problemas de oscilación. Verifique la oscilación después de cada paso.
1. Verifique que todos los soportes de las aletas estén firmemente aseguradas al motor.
2. Asegúrese de que el dosel y el soporte de montaje estén firmemente asegurados a la viga del techno.
3. Si la oscilación de la aleta sigue siendo visible, es posible que al intercambiar dos aletas adyacentes (lado a lado) se redistribuya el peso y el funcionamiento sea más suave.
15
ETL-ES-Jax(J hook)-WH22
WARRANTY
GARANTÍA
This Westinghouse Lighting Fan offers a 15 Year Warranty to the original owner against defects in material and workmanship.
This warranty is in lieu of all other warranties expressed or implied.
Westinghouse Lighting will repair or replace the parts needed, and/or, replace the ceiling fan, if the defective is due to faulty materials or workmanship.
Years 1 & 2 – Westinghouse Lighting will repair or replace this ceiling fan.
After Year 2 – Warranty is limited to the motor for 15 Years from the date of purchase
This warranty does not cover acts of nature such as lightning damage, or corrosion and discoloration of components, nor does it cover damages caused through abuse, improper installation, surges in electric current,
or acts of third parties. This warranty does not cover broken glass after installation. If this ceiling fan fails during the warranty period, return defective product to seller. Warranty terms and conditions of seller apply.
If replacement product is not available through seller, please contact www.westinghouselighting.com/contact-us.
Este ventilador de Westinghouse Lighting se ofrece con una garantía de 15 años al comprador original frente a defectos de material y de mano de obra.
Esta garantía sustituye cualquier otra garantía expresa o implícita.
Westinghouse Lighting reparará o reemplazará las piezas necesarias y/o reemplazará el ventilador de techo si el fallo se debe a defectos de material o de mano de obra.
Primeros 2 años: Westinghouse Lighting reparará o reemplazará este ventilador de techo.
Después del segundo año: la garantía queda limitada al motor un período de 15 años a partir de la fecha de compra
Esta garantía no cubre los daños debidos a fenómenos naturales, como daños por caída de rayos, corrosión o decoloración de los componentes, ni tampoco los daños causados por un uso inadecuado, una instalación
incorrecta, sobretensiones eléctricas o actos de terceros. Esta garantía no cubre la rotura de vidrio una vez que se haya realizado la instalación. Si el ventilador de techo falla durante el período de garantía, devuelva el
producto defectuoso al distribuidor. Se aplican los términos y condiciones de garantía del vendedor. Si el producto de reemplazo no está disponible por medio del distribuidor, póngase en contacto con nosotros a través
de www.westinghouselighting.com/contact-us.
16
ETL-ES-Jax(J hook)-WH22
1
2
3
# Description
1. . . . . . . . . . . . . . . . . . . . . . Mounting Bracket
2. . . . . . . . . . . . . . . . . . . . . . Blade
3. . . . . . . . . . . . . . . . . . . . . . Wall Control
4. . . . . . . . . . . . . . . . . . . . . . Hardware Pack
No. Descripción
1. . . . . . . . . . . . . . . . . . . . . .Soporte de montaje
2. . . . . . . . . . . . . . . . . . . . . .Aleta
3. . . . . . . . . . . . . . . . . . . . . .Control de pared
4. . . . . . . . . . . . . . . . . . . . . .Tornillería
4
PARTS LIST
LISTA DE REPUESTOS
17
ETL-ES-Jax(J hook)-WH22
18
ETL-ES-Jax(J hook)-WH22
19
ETL-ES-Jax(J hook)-WH22
ETL-ES-Jax(J hook)-WH22
and Westinghouse are trademarks of
We
stinghouse Electric Corporation.
Used under license
by Westinghouse Lighting.
All Rights Reserved.
Made in China
Westinghouse Lighting,
Philadelphia, PA 19154-1029, U.S.A.
www.westinghouselighting.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Westinghouse 7840900 Instrucciones de operación

Categoría
Ventiladores domésticos
Tipo
Instrucciones de operación