Westinghouse 7212800 Guía de instalación

Categoría
Ventiladores domésticos
Tipo
Guía de instalación
Net Weight: 11.0 LBS
Peso Neto: 5.0 KGS
ETL-ES-Hadley-R-WH16
OWNER'S MANUAL
MANUAL DEL USUARIO
Hadley
Please write model number here for future reference: /
Por favor, incluya el número del modelo aquí para futura referencia:
2
ETL-ES-Hadley-R-WH16
1. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards (ANSI/NFPA 70), including fire-rated construction.
2. Use this unit only in the manner intended by the manufacturer. If you have any questions contact the manufacturer.
3. After making the wire connections, gently push connections into outlet box with wire nuts pointing up. The wires should be spread apart with the grounded conductor and the equipment-grounding con
ductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box.
4. Before you begin installing the fan, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
5. Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.
6. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
7. Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade.
8. To reduce the risk of fire, electric shock, or personal injury, this fan must be mounted to an outlet box marked suitable for fan support, and use the mounting screws provided with the outlet box. (Mounting
must support at least 35 lbs.)
9. WARNING! Do not bend blade holders during installation to motor, balancing or during cleaning. Do not insert foreign object between rotating blades.
10. Attach the mounting bracket using only the hardware supplied with the outlet box. Fan is only to be mounted to an outlet box marked Acceptable for Fan Support”.
11. WARNING! To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.
12. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.
13. NEVER place a switch where it can be reached from a tub or shower.
14. The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment manufacturer’s guideline safety standards such as
those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
15. Before servicing or cleaning unit, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means can
not be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
16. All set screws must be checked and re-tightened where necessary before installation.
17. The appliance is not intended for use by young children or infirmed persons without supervision. Young children should be supervised to ensure that they do not play with the appliance.
TOOLS REQUIRED
Phillips Screwdriver Wire Cutters Pliers Step Ladder
SAFETY TIPS
OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR PERSONAL INJURY, MOUNT TO OUTLET BOX MARKED 'ACCEPTABLE FOR FAN SUPPORT OF 15.9 KG (35 LBS) OR LESS' AND
USE MOUNTING SCREWS PROVIDED WITH THE OUTLET BOX AND/OR SUPPORT DIRECTLY FROM BUILDING STRUCTURE. MOST OUTLET BOXES COMMONLY USED FOR THE SUPPORT OF
.LUMINARIES ARE NOT ACCEPTABLE FOR FAN SUPPORT AND MAY NEED TO BE REPLACED. CONSULT A QUALIFIED ELECTRICIAN IF IN DOUBT
3
ETL-ES-Hadley-R-WH16
HERRAMIENTAS NECESARIAS
Destornillador Phillips Pinzas de corte Pinzas Escalera de mano
1. El trabajo de instalación y el cableado eléctrico los deben efectuar personas calificadas cumpliendo con todos los códigos y las normas aplicables (ANSI/NFPA 70), incluyendo las de incendio.
2. Use esta unidad sólo de la manera en que el fabricante quiere que se haga. Si tiene dudas, llame al fabricante.
3. Después de hacer las conexiones, empuje con cuidado las conexiones dentro de la caja de empalmes con los conectores de cables mirando hacia arriba. Se deben separar los cables: el conductor de puesta a tierra y el conductor
de puesta a tierra del equipo a un lado de la caja de embutir, y el conductor que no tiene puesta a tierra del otro lado de la misma.
4. Antes de comenzar a instalar el ventilador, apague la alimentación en el panel de servicio y bloquee el medio de desconexión del servicio para evitar que se encienda accidentalmente. Cuando no se puede bloquear el medio
de desconexión del servicio eléctrico, fije de manera segura y un dispositivo de advertencia prominente, como un rótulo, al panel de servicio.
5. ¡Tenga cuidado! Lea todas las instrucciones y la información de seguridad antes de instalar su ventilador nuevo. Revise los diagramas de montaje incluidos.
6. Al cortar o perforar una pared o el techo, no dañe el cableado eléctrico y otras instalaciones de servicios públicos ocultos.
7. Asegúrese de que el sitio para la instalación que escoja permita que el ventilador gire libremente sin obstrucciones. Deje un espacio mínimo de 7 pies desde le piso hasta el borde posterior de la aleta.
8. Para reducir el riesgo de incendios, choques eléctricos o heridas graves personales, este ventilador se debe montar sobre una caja de embutir que tenga una marca que indique que es adecuada para soportar un ventilador.
Además debe utilizar los tornillos correspondientes incluidos con la caja de embutir. (El montaje debe soportar por lo menos 15.9 kgs.)
9. ¡ADVERTENCIA! No doble los soportes para las paletas durante la instalación al motor, al balancear o durante la limpieza. No inserte objetos extraños entre las paletas mientras giran.
10. Fije el soporte de montaje usando sólo la tornillería suministrada con la caja de embutir. El ventilador sólo se debe montar en una caja de embutir marcada Acceptable for Fan Support” (Aceptable para soportar ventiladores).
11. ¡ADVERTENCIA! Para reducir el riesgo de incendios o choques eléctricos, no use este ventilador con un dispositivo de control de velocidad de estado sólido para ventilador, o un control de velocidad variable.
12. Si esta unidad se instalará sobre una bañera o una ducha, debe estar identificada como adecuada para ese tipo de aplicación.
13. NUNCA coloque un interruptor donde se pueda alcanzar desde una bañera o una ducha.
14. Es posible que la operación de esta unidad afecte el flujo de aire de combustión necesario para la operación segura de equipo que quema combustible. Siga la directrices de seguridad del fabricante de equipo de calefacción
como las publicadas por la Asociación Nacional de Protección Contra Incendios (National Fire Protection Association, NFPA), y la Sociedad Americana para Ingenieros de Calefacción, Refrigeración y Aire Acondicionado
(American Society for Heating, Refrigeration and Air Conditioning Engineers, ASHRAE) y las autoridades del código local.
15. Antes de efectuar tareas de servicio o limpieza en la unidad, apague la alimentación en el panel de servicio y bloquee el medio de desconexión del servicio para evitar que se encienda accidentalmente. Cuando no se puede
bloquear el medio de desconexión del servicio eléctrico, fije de manera segura y un dispositivo de advertencia prominente, como un rótulo, al panel de servicio.
16. Antes de realizar la instalación, es importante comprobar y volver a ajustar todos los tornillos, según corresponda.
17. El dispositivo no ha sido diseñador para ser utilizado por niños o personas enfermas sin supervisión. Los niños deben ser supervisados para asegurarse de que no juegan con el dispositivo.
CONSEJOS DE SEGURIDAD
HAGA LO SIGUIENTE: LEA Y GUARDE ESTAS INSTRUCCIONES
ADVERTENCIA: PARA REDUCIR EL RIESGO DE INCENDIO, DESCARGA ELÉCTRICA O HERIDAS GRAVES PERSONALES, MONTE EN UNA CAJA DE EMBUTIR ROTULADA “ADECUADA PARA VENTILADORES DE 15,9 KG (35
LB) O MENOS” UTILIZANDO LOS TORNILLOS DE MONTAJE INCLUIDOS CON LA CAJA DE EMBUTIR Y/O MONTE DIRECTAMENTE EN LA ESTRUCTURA DEL EDIFICIO LA MAYORÍA DE LAS CAJAS DE EMBUTIR UTILIZADAS
.NORMALMENTE CON ARTEFACTOS DE ILUMINACIÓN NO SON ADECUADAS PARA VENTILADORES Y DEBERÍAN SER REEMPLAZADAS. SI TIENE PREGUNTAS, CONSULTE A UN ELECTRICISTA CERTIFICADO
4
ETL-ES-Hadley-R-WH16
COMBO-BLADE
Combo-Blades feature two high quality finishes on one blade. Select the one that best complements
your decor, or change the style with just a flip of the blade.
NOTE: Combo-Blade finishes vary, depending upon model.
ASPAS DE DOBLE CARA
Las aspas del rotor de doble cara presentan dos superficies con un acabado de alta calidad. Invirtiendo
las aspas puede Ud. producir un efecto decorativo adaptado a su ambiente o crear una decoración
completamente nueva.
Observación: las superficies de las aspas de doble cara son distintas dependiendo del modelo.
FEATURES
CARACTERÍSTICAS
5
ETL-ES-Hadley-R-WH16
Unpack and inspect fan carefully to be certain all contents are included.
Turn off power at fuse box to avoid possible electrical shock.
Use metal outlet box suitable for fan support (must support 35 lbs). Before
attaching fan to outlet box, ensure the outlet box is securely fastened by at
least two points to a structural ceiling member (a loose box will cause the
fan to wobble).
PREPARING FOR INSTALLATION
ANTES DE LA INSTALACIÓN
Quite el envoltorio e inspeccione detenidamente el ventilador para verificar
que todas las piezas estén incluidas. Apague la alimentación en la caja de
fusibles para evitar la posibilidad de descarga eléctrica.
Use una caja de embutir de metal adecuada para soportar un ventilador
(debe soportar 35 libras). Antes de fijar el ventilador a la caja de embutir
asegúrese de que la misma esté fijada de manera segura en por lo menos
dos puntos a un miembro estructural del techo (una caja suelta haría
que el ventilador oscile).
1
2
6
ETL-ES-Hadley-R-WH16
MOUNTING BRACKET INSTALLATION
INSTALACIÓN CON SOPORTE DE MONTAJE
Remove screws from motor bracket and mounting plate. Hang fan from
mounting plate by inserting "T"-shaped end of bracket into slot opening of
mounting plate. This will allow for hands free wiring.
Extraiga los tornillos del soporte del motor y de la placa de montaje.
Cuelgue el ventilador de la placa de montaje insertando el extremo del
soporte con forma de “T adentro de la ranura de la placa de montaje. De
este modo, tendrá las dos manos libres para hacer el cableado.
4
3
Remove the screws and star washers (1) from the bracket as shown above.
Loosen (do not remove) the screws (2) from the bracket as shown above.
Install mounting bracket to outlet box in ceiling using the screws and washers
provided with the outlet box.
Quite los tornillos y las arandelas en estrella (1) del soporte como se indica arriba.
Afloje (no quite) los tornillos (2) del soporte como se indica arriba.
Instale el soporte de montaje a la caja de embutir del techo con la tornillería incluidos
con la caja de embutir.
1
1
2
2
7
ETL-ES-Hadley-R-WH16
5
While fan is hanging from the mounting plate, connect the wires with wire connectors (included), using the following steps
for wiring options.
Mientras el ventilador está colgado de la placa de montaje, conecte los cables con los conectores para cables (incluidos)
usando los siguientes pasos para opciones de cableado.
MOUNTING
MONTAJE
8
ETL-ES-Hadley-R-WH16
7
*Connect blue wire only if attaching light kit with fan.
Follow diagram above to make wiring connections for wall control operation.
6
*Connect blue wire only if attaching light kit with fan.
Follow diagram above to make wiring connections for fan pull chain control.
PULL CHAIN WIRING OPTION
WALL CONTROL WIRING OPTION
Siga las instrucciones del diagrama anterior para hacer las conexiones de
cableado para el ventilador con control de pared.
Siga las instrucciones del diagrama anterior para hacer las conexiones de
cableado para el ventilador controlado con cadenilla de tiro.
OPCIÓN DE CABLEADO PARA CADENILLA DE TIRO
OPCIÓN DE CABLEADO PARA CONTROL DE PARED
WIRING OPTIONS
OPCIÓN DE CABLEADO
Empuje el motor hacia arriba y fije el motor
a la placa de montaje asegurando firmemente
con los tornillos y las arandelas incluidos.
Push motor upward and attach the motor to
the mounting plate by tightly securing with
screws and washers provided.
9
ETL-ES-Hadley-R-WH16
MOUNTING
MONTAJE
8
The decorative motor housing has two mating slots (1) and
two mating holes (2). Position both slots on the motor housing
directly under and in line with two screws in the mounting
bracket (3). Lift the motor housing, allowing the two screws to
slide into the mating slots. Rotate the motor housing clockwise
until both screws from the mounting bracket drop into the slot
recesses. Tighten screws securely.
El alojamiento decorativo del motor tiene dos ranuras coinciden-
tes (1) y dos agujeros coincidentes (2). Coloque ambas ranuras
del alojamiento del motor directamente abajo y en línea con los
dos tornillos del soporte de montaje (3). Eleve el alojamiento del
motor, permitiendo que los dos tornillos se deslicen dentro de
las ranuras. Gire el alojamiento del motor en sentido horario
hasta que ambos tornillos del soporte de montaje caigan aden-
tro de las ranuras. Apriete los tornillos asegurándolos.
9
Install two screws and star washers into the mating
holes of the motor housing and tighten to secure the
housing to the mounting bracket.
Instale los dos tornillos y las arandelas en estrella en
los agujeros coincidentes del alojamiento del motor y
ajústelos para asegurar el alojamiento al soporte de
montaje.
10
1
2
3
1
2
10
ETL-ES-Hadley-R-WH16
BLADE INSTALLATION
INSTALACIÓN DE LAS PALETAS
Check the motor for plastic shipping stabilizer tabs (1), and remove them if they are
present. Attach blade assembly to motor using the noise-dampening motor gaskets (2) and
motor screws provided. Tighten screws ecurely. NOTE: Some models do not utilize motor
gaskets, washers, or stabilizer tabs.
Verifique si hay lengüetas plásticas de embalaje para sostener al motor (1) y descártelas.
Fije el conjunto de las paletas al motor usando las juntas reductoras de sonido del motor (2)
y los tornillos para el motor incluidos. Apriete los tornillos asegurándolos. NOTA: Algunos
modelos no utilizan juntas para el motor, arandelas o lengüetas de embalaje.
12
11
Attach blade brackets to blades using the blade bracket screws (1), metal
washers (2), and fabric washers (3), if provided. NOTE: Some models do not
utilize fabric washers (3).
Fije los soportes para aletas a las aletas con los tornillos (1), las arandelas
de metal (2) y las de tela (3), si corresponde. NOTA: Algunos modelos no
utilizan arandelas de tela (3).
1
2
1
3
2
2
11
ETL-ES-Hadley-R-WH16
LIGHT FIXTURE INSTALLATION
INSTALACIÓN DEL ARTEFACTO LUMINOSO
13
Find the wire plugs from the light kit and from the motor and slide together. Connect the blue wire from the switch housing, to the black wire from the light kit, and the
white wire from the switch housing to the white wire from the light kit. Attach light kit to the switch housing using three small screws provided.
Identifique los conectores para cables de salida del artefacto luminoso y del motor y deslícelos para unirlos. Conecte el cable azul del alojamiento del interruptor al cable
negro del artefacto luminoso y el cable blanco del alojamiento del interruptor al cable blanco del artefacto luminoso. Conecte el artefacto luminoso al alojamiento del inter-
ruptor con los tres tornillos pequeños incluidos.
12
ETL-ES-Hadley-R-WH16
Unscrew and remove the finial (1), decorative cap (2), nut (3), and rubber/metal washer (4) from the bottom of the light kit. Install the bulbs (included).
Desenrosque y quite el florón (1), la tapa decorativa (2), la tuerca (3) y la arandela de caucho/metal (4) de la parte inferior del juego de luces. Instale las bombillas de luz
(incluidas).
LIGHT FIXTURE INSTALLATION
INSTALACIÓN DEL ARTEFACTO LUMINOSO
14
4
3
2
1
13
ETL-ES-Hadley-R-WH16
15
Install the glass (5) onto the light kit and tighten the washer (4) and nut (3) onto the bottom of glass. Make sure the ceiling fan pull chain is threaded through the side hole
in the bottom of the glass. Place decorative cap (2) over the bottom of glass and secure by tightening decorative finial (1).
Note: (6) Make sure the side hole on the decorative cap lines up with the side hole on the bottom of the glass so that the fan pull chain operates smoothly.
Instale la pantalla de vidrio (5) en el juego de luces y ajuste la arandela (4) y la tuerca (3) en la parte inferior de la pantalla. Asegúrese de que la cadenilla de tiro del ventila-
dor de techo pasa por el agujero lateral de la parte inferior de la pantalla. Coloque la tapa decorativa (2) sobre la parte inferior de la pantalla de vidrio y asegúrela ajustando
el florón decorativo (1).
Nota: (6) Asegúrese de que el agujero lateral de la tapa decorativa esté alineado con el agujero lateral de la parte inferior de la pantalla de vidrio para que la cadenilla de tiro
del ventilador de techo funcione sin inconvenientes.
5
4
3
2
1
6
14
ETL-ES-Hadley-R-WH16
16
Assemble decorative fob and extension chains from hardware bag to fan pull chains by inserting end of chain into chain coupling. Confirm chains are held by lightly pulling
both chains in coupling.
Sujeta las cadenillas largas de tiro con las piezas finales correspondientes, a las cadenillas del ventilador, introduciendo el extremo de la cadenilla larga en la pieza de unión.
Asegúrese de que las cadenillas están bien sujetas, tirando ligeramente de ambas cadenillas en la pieza de unión.
15
OPERATION AND MAINTENANCE
Operation
Turn on the power and check operation of fan. The pull chain controls the fan speeds as follows: 1 pull - high; 2 pulls - medium; 3 pulls - low; 4 pulls - off.
Speed settings for warm or cool weather depend on factors such as room size, ceiling height, number of fans and so on.
The slide switch controls direction, forward or reverse.
Warm weather/down position - (Forward) Fan turns counterclockwise direction. A downward air flow creates a cooling effect as shown in illustration A.
This allows you to set your air conditioner on a higher temperature setting without affecting your comfort.
Cool weather/up position - (Reverse) Fan turns clockwise direction. An upward airflow moves warm air off the ceiling area as shown in illustration B.
This allows you to set your heating unit on a lower setting without affecting your comfort.
NOTE: Turn off and wait for fan to stop before changing the setting of the forward/reverse slide switch.
Maintenance
1. Because of the fans natural movement, some connections may become loose. Check the support connections, brackets, and blade attachments twice a year.
Make sure they are secure.
2. Clean your fan periodically to help maintain its new appearance over the years. Do not use water when cleaning.
This could damage the motor, or the wood, or possibly cause electrical shock.
3. Use only a soft brush or lint-free cloth to avoid scratching the finish. The plating is sealed with a lacquer coating to minimize discoloration or tarnishing.
4. There is no need to oil your fan. The motor has permanently lubricated bearings.
ETL-ES-Hadley-R-WH16
16
ETL-ES-Hadley-R-WH16
OPERACIÓN Y MANTENIMIENTO
Operación
Encienda el ventilador y verifique su funcionamiento. La cadenilla de tiro controla las velocidades del ventilador de la siguiente manera:
1 jalón – rápida; 2 jalones - mediana; 3 jalones - lenta; 4 jalones - apagado.
Las velocidades para clima cálido o frío dependen de factores como el tamaño de la habitación, la altura del ventilador, el número de ventiladores, etc.
El interruptor deslizante controla la dirección, hacia adelante o hacia atrás.
Clima cálido/posición hacia abajo - (Adelante) El ventilador gira en sentido contrahorario. Una corriente de aire descendente crea un efecto refrescante como
lo indica la ilustración A.
Esto le permite ajustar el aire acondicionado a una temperatura más alta sin que afecte su comodidad.
Clima frío/posición hacia arriba - (Atrás) El ventilador gira en sentido de las agujas del reloj. Una corriente de aire ascendente aleja el aire caliente del área del
ventilador de techo como lo indica la ilustración B. Esto le permite ajustar la calefacción a un nivel más bajo sin que afecte su comodidad.
NOTA: Apague el ventilador y espere a que se detenga antes de cambiar la dirección hacia adelante/atrás con el interruptor deslizante.
Mantenimiento
1. El movimiento natural del ventilador podría hacer que se aflojen algunas conexiones. Verifique las conexiones de soporte, las piezas de fijación y los accesorios de las
aletas dos veces al año. Asegure de que estén apretadas.
2. Limpie el ventilador periódicamente para ayudar a mantener su apariencia nueva con el correr de los años. No use agua para limpiarlo, ya que podría dañar el motor o
la madera o causar descarga eléctrica.
3. Use sólo un cepillo blando o un trapo sin pelusa para no rayar el acabado. El enchapado está sellado con una capa de laca para minimizar la decoloración o pérdida del brillo.
4. No hay necesidad de aceitar el ventilador. El motor tiene cojinetes de lubricación permanente.
17
ETL-ES-Hadley-R-WH16
If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation, or
wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults, please
check this Trouble Shooting Chart. If a problem cannot be remedied, please consult with your authorized electrician
and do not attempt any electrical repairs yourself.
TROUBLESHOOTING GUIDE
TROUBLE
1. If fan does not start:
2. If fan sounds noisy:
3. If fan wobbles:
4. If light does not work:
SUGGESTED REMEDY
1. Check main and branch circuit fuses or circuit breakers.
2. Check wire connections as performed in step #6 or #7 of installation.
CAUTION: Make sure main power is turned off.
3. Make sure forward/reverse switch is firmly in up or down position.
Fan will not operate when switch is in the middle.
4. If the fan still will not start, contact a qualified electrician.
Do not attempt to troubleshoot internal electrical connections yourself.
1. Check to make sure all screws in motor housing are snug (not over tightened).
2. Check to make sure the screws which attach the fan blade holder to the motor are tight.
3. Some fan motors are sensitive to signals from Solid State variable speed controls.
DO NOT USE a Solid State variable speed control.
4. Allow “break-in period of 24 hours. Most noises associated with a new fan will disappear
after this period.
All blades are weighed and grouped by weight. Natural woods vary in density which could cause
the fan to wobble even though all blades are weight-matched. The following procedures should
eliminate most of the wobble. Check for wobble after each step.
1. Check that all blades are screwed firmly into blade holders.
2. Check that all blade holders are tightened securely to motor.
3. Make sure that canopy and mounting bracket are tightened securely to ceiling joist.
4. If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can redistribute
the weight and possibly result in smoother operation.
1. Check to see that the wire connections in the switch housing are connected.
2. Check for faulty light bulbs.
3. If light kit will still not operate, contact a qualified electrician for assistance.
NOTICE
This ‘Energy Policy Act 2005’ compliant fan includes a device
that limits the total wattage of its light xture to 190 watts.
By installing a combination of light bulbs that exceeds 190 watts or if an
electrical surge causes the wattage to exceed 190 watts the light xture
will automatically turn o.
To restore the light levels, make sure the total wattage of the light bulbs
does not exceed 190 watts and follow the applicable directions below:
For fans with Pull Chains:
Pull the light xtures pull chain two times to reset the light xture.
If the power to your fan is controlled by a toggle wall switch, it may
be necessary to turn the power o and back on at the wall switch.
For fans with Wall Controls:
Press the light button on the wall control o and on”
once to reset the light xture.
For fans with Remote Controls:
If you verify the wattage and the lights do not turn on, press the
light button on the remote control twice to reset the light xture.
NOTE: If the procedures above do not reset the lights,
turn o the main power source, located at the breaker panel or box,
and then turn it on again.
ETL-ES-Hadley-R-WH16
Si tiene dificultades para hacer funcionar su nuevo ventilador, podría ser a causa del armado, instalación o
cableado incorrectos. En algunos casos, estos errores de instalación podrían ser confundidos con defectos.
Si experiencia alguna falla, consulte esta guía para solucionar problemas. Si no puede solucionar el prob-
lema, consulte a un electricista calificado y no intente reparar conexiones eléctricas.
GUÍA PARA SOLUCIONAR PROBLEMAS
PROBLEMA
1. Si el ventilador no arranca:
2. Si el ventilador es ruidoso:
3. Si el ventilador oscila:
4. Si la luz no funciona:
SOLUCIÓN SUGERIDA
1. Compruebe los fusibles o disyuntores principales y del circuito derivado.
2. Compruebe el cableado del bloque de terminales como lo hizo en el paso No. 6 ó 7 de
la instalación. ADVERTENCIA: Asegúrese de que la alimentación principal esté apagada.
3. Asegúrese de que el interruptor de marcha adelante/atrás esté firmemente en su posición.
El ventilador no funcionará si el interruptor está en el medio.
4. Si el ventilador no arranca, póngase en contacto con un electricista calificado. No intente
reparar conexiones eléctricas internas.
1. Compruebe para asegurarse de que todos los tornillos del alojamiento del motor estén ajustados
(no los apriete demasiado).
2. Compruebe para asegurarse de que los tornillos que fijan el soporte de la aleta del ventilador
al motor estén apretados.
3. NO USE un control de velocidad variable de estado sólido.
4. Permita el "rodaje" del ventilador durante un período de 24 horas. La mayoría de los ruidos
asociados con el ventilador nuevo desaparecerán después de este período.
Todas las aletas se pesan y agrupan según el peso. Las maderas naturales varían en densidad y podrían hacer
que el ventilador oscile aún cuando todas las aletas estén agrupadas por peso. Los siguientes procedimientos
deberían eliminar la mayoría de los problemas de oscilación. Verifique la oscilación después de cada paso.
1. Verifique que todas las aletas estén firmemente atornilladas a los soportes de las aletas.
2. Verifique que todos los soportes de las aletas estén firmemente aseguradas al motor.
3. Asegúrese de que el dosel y el soporte de montaje estén firmemente asegurados a la viga
del cielorraso.
4. Si la oscilación de la aleta sigue siendo visible, es posible que al intercambiar dos aletas adyacentes
(lado a lado) se redistribuya el peso y el funcionamiento sea más suave.
1. Verifique que el conector molex del alojamiento del interruptor esté conectado.
2. Compruebe si hay lámparas defectuosas.
3. Si el conjunto de luces no funciona, póngase en contacto con un electricista calificado.
AVISO
Este ventilador, que cumple con las exigencias del 'Energy Policy Act 2005',
incluye un accesorio que limita el vataje total de su lámpara a 190 vatios.
Si usted instala una combinación de bombillas que sobrepasen
los 190 vatios o si un sobrevoltaje hace que el voltaje sea superior
a 190 vatios la lámpara se apagará.
Para restablecer el nivel de luminosidad, asegúrese que el vataje total
de las bombillas no sobrepase los 190 vatios y siga las indicaciones
aplicables a continuación:
Para ventiladores con Cadenilla de tiro:
Jale la cadenilla de la lámpara dos veces para reiniciarla. Si la energía
de su ventilador se controla con un interruptor en la pared,
puede ser necesario apagar el interruptor y luego encenderlo.
Para ventiladores con Control de pared:
Presione el botón en la pared una vez para apagar y una vez
para encender, para así reiniciar la lámpara.
Para ventiladores con Control remoto:
Si verica el vataje y la luz no enciende, presione el botón para
la luz en el control remoto dos veces para reiniciar la lámpara.
NOTA: Si los procedimientos mencionados no reinician la lámpara,
desconecte la fuente principal de energía, ubicada
en el panel o caja de interruptor, y vuélvala a conectar.
19
ETL-ES-Hadley-R-WH16
4
2
3
PARTS LIST
LISTA DE REPUESTOS
1
8
7
5
6
# Description
1 . . . . . . . . . . . . . . . . . . Mounting Bracket
2 . . . . . . . . . . . . . . . . . . Blade Bracket
3 . . . . . . . . . . . . . . . . . . Blade
4 . . . . . . . . . . . . . . . . . . Glass
5 . . . . . . . . . . . . . . . . . . Fan Speed Switch
6 . . . . . . . . . . . . . . . . . . Light Control Switch
7 . . . . . . . . . . . . . . . . . . Capacitor
8 . . . . . . . . . . . . . . . . . . Hardware Pack
No. Descripción
1 . . . . . . . . . . . . . . . . . . Soporte de montaje
2 . . . . . . . . . . . . . . . . . . Soporte para aleta
3 . . . . . . . . . . . . . . . . . . Aleta
4 . . . . . . . . . . . . . . . . . . Pantalla de vidrio
5 . . . . . . . . . . . . . . . . . . Interruptor de control de
velocidad para ventilador
6 . . . . . . . . . . . . . . . . . . Interruptor de control de luz
7 . . . . . . . . . . . . . . . . . . Condensador
8 . . . . . . . . . . . . . . . . . . Tornillería
Westinghouse Lighting, Philadelphia, PA 19154-1029, U.S.A.
www.westinghouselighting.com
, WESTINGHOUSE, and INNOVATION YOU CAN BE SURE OF
are trademarks of Westinghouse Electric Corporation
Used under license by Westinghouse Lighting
All rights reserved.
Made in China
ETL-ES-Hadley-R-WH16
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Westinghouse 7212800 Guía de instalación

Categoría
Ventiladores domésticos
Tipo
Guía de instalación

en otros idiomas