OWNER'S MANUAL
MANUAL DEL USUARIO
MR
Vector Elite
TM
Please write model number here for future reference: /
Por favor, incluya el número del modelo aquí para futura referencia:
Net Weight: 13.00 LBS
Peso Neto: 5.9 KGS
2
UL-ES-VectorElite-WH09
1. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards (ANSI/NFPA 70-1999), including fire-rated construction.
2. Use this unit only in the manner intended by the manufacturer. If you have any questions contact the manufacturer.
3. After making the wire connections, gently push connections into outlet box with wire nuts pointing up. The wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one
side of the outlet box and ungrounded conductor on the other side of the outlet box.
4. Before you begin installing the fan, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be
locked, securely fasten a prominent warning device, such as a tag, to the service panel.
5. Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.
6. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
7. Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade.
8. To reduce the risk of fire, electric shock, or personal injury, this fan must be mounted to an outlet box marked suitable for fan support, and use the mounting screws provided with the outlet box. (Mounting must
support at least 35 lbs.)
9. WARNING! Do not bend blade holders during installation to motor, balancing or during cleaning. Do not insert foreign object between rotating blades.
10. Attach the mounting bracket using only the hardware supplied with the outlet box. Fan is only to be mounted to an outlet box marked “Acceptable for Fan Support”.
11. WARNING! To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.
12. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.
13. NEVER place a switch where it can be reached from a tub or shower.
14. The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment manufacturer’s guideline safety standards such as those
published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
15. Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be
locked, securely fasten a prominent warning device, such as a tag, to the service panel.
16. All set screws must be checked and re-tightened where necessary before installation.
SAFETY TIPS
OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR PERSONAL INJURY, MOUNT TO OUTLET BOX MARKED "ACCEPTABLE FOR FAN SUPPORT",
AND USE THE OUTLET SCREWS PROVIDED WITH THE OUTLET BOX. MOST OUTLET BOXES COMMONLY USED FOR THE SUPPORT OF LIGHTING FIXTURES
ARE NOT ACCEPTABLE FOR FAN SUPPORT AND MAY NEED TO BE REPLACED. CONSULT A QUALIFIED ELECTRICIAN IF IN DOUBT.
TOOLS REQUIRED
Phillips Screwdriver Wire Cutters Pliers Step Ladder
3
UL-ES-VectorElite-WH09
1. El trabajo de instalación y el cableado eléctrico los deben efectuar personas calificadas cumpliendo con todos los códigos y las normas aplicables (ANSI/NFPA 70-1999), incluyendo las de incendio.
2. Use esta unidad sólo de la manera en que el fabricante quiere que se haga. Si tiene dudas, llame al fabricante.
3. Después de hacer las conexiones, empuje con cuidado las conexiones dentro de la caja de empalmes con los conectores de cables mirando hacia arriba. Se deben separar los cables: el conductor de puesta a tierra y el conductor
de puesta a tierra del equipo a un lado de la caja de embutir, y el conductor que no tiene puesta a tierra del otro lado de la misma.
4. Antes de comenzar a instalar el ventilador, apague la alimentación en el panel de servicio y bloquee el medio de desconexión del servicio para evitar que se encienda accidentalmente. Cuando no se puede bloquear el medio
de desconexión del servicio eléctrico, fije de manera segura y un dispositivo de advertencia prominente, como un rótulo, al panel de servicio.
5. ¡Tenga cuidado! Lea todas las instrucciones y la información de seguridad antes de instalar su ventilador nuevo. Revise los diagramas de montaje incluidos.
6. Al cortar o perforar una pared o el cielo raso, no dañe el cableado eléctrico y otras instalaciones de servicios públicos ocultos.
7. Asegúrese de que el sitio para la instalación que escoja permita que el ventilador gire libremente sin obstrucciones. Deje un espacio mínimo de 7 pies desde le piso hasta el borde posterior de la paleta.
8. Para reducir el riesgo de incendios, choques eléctricos o lesiones personales, este ventilador se debe montar sobre una caja de embutir que tenga una marca que indique que es adecuada para soportar un ventilador.
Además debe utilizar los tornillos correspondientes incluidos con la caja de embutir. (El montaje debe soportar por lo menos 15.87 kgs.)
9. ¡ADVERTENCIA! No doble los soportes para las paletas durante la instalación al motor, al balancear o durante la limpieza. No inserte objetos extraños entre las paletas mientras giran.
10. Fije el soporte de montaje usando sólo la tornillería suministrada con la caja de embutir. El ventilador sólo se debe montar en una caja de embutir marcada “Acceptable for Fan Support” (Aceptable para soportar ventiladores).
11. ¡ADVERTENCIA! Para reducir el riesgo de incendios o choques eléctricos, no use este ventilador con un dispositivo de control de velocidad de estado sólido para ventilador, o un control de velocidad variable.
12. Si esta unidad se instalará sobre una bañera o una ducha, debe estar identificada como adecuada para ese tipo de aplicación.
13. NUNCA coloque un interruptor donde se pueda alcanzar desde una bañera o una ducha.
14. Es posible que la operación de esta unidad afecte el flujo de aire de combustión necesario para la operación segura de equipo que quema combustible. Siga la directrices de seguridad del fabricante de equipo de calefacción
como las publicadas por la Asociación Nacional de Protección Contra Incendios (National Fire Protection Association, NFPA), y la Sociedad Americana para Ingenieros de Calefacción, Refrigeración y Aire Acondicionado
(American Society for Heating, Refrigeration and Air Conditioning Engineers, ASHRAE) y las autoridades del código local.
15. Antes de efectuar tareas de servicio o limpieza en la unidad, apague la alimentación en el panel de servicio y bloquee el medio de desconexión del servicio para evitar que se encienda accidentalmente. Cuando no se puede
bloquear el medio de desconexión del servicio eléctrico, fije de manera segura y un dispositivo de advertencia prominente, como un rótulo, al panel de servicio.
16. Antes de realizar la instalación, es importante comprobar y volver a ajustar todos los tornillos, según corresponda.
CONSEJOS DE SEGURIDAD
HAGA LO SIGUIENTE: LEA Y GUARDE ESTAS INSTRUCCIONES
ADVERTENCIA: PARA REDUCIR EL RIESGO DE INCENDIO, DESCARGA ELÉCTRICA O LESIONES PERSONALES, MONTE EL VENTILADOR EN UNA CAJA DE EMBUTIR ROTULADA “ADECUADA PARA
VENTILADORES”, Y UTILICE LOS TORNILLOS DE MONTAJE INCLUIDOS CON LA CAJA DE EMBUTIR. LA MAYORÍA DE LAS CAJAS DE EMBUTIR UTILIZADAS NORMALMENTE PARA ARTEFACTOS DE
ILUMINACIÓN NO SON ADECUADAS PARA VENTILADORES Y DEBERÍAN SER REEMPLAZADAS. SI TIENE PREGUNTAS, CONSULTE A UN ELECTRICISTA CERTIFICADO.
HERRAMIENTAS NECESARIAS
Destornillador Phillips Pinzas de corte Pinzas Escalera de mano
4
UL-ES-VectorElite-WH09
FEATURES
CARACTERÍSTICAS
DOWNROD
INSTALLATION
INSTALACIÓN CON
VARILLA VERTICAL
For normal ceilings
Para cielorrasos normales
VAULTED CEILING
INSTALLATION
INSTALACIÓN PARA
CIELORRASOS ABOVEDADOS
May require a longer downrod
(sold separately)
Podría requerir una varilla
vertical más larga
(se vende por separado)
FLUSH MOUNT INSTALLATION
INSTALACIÓN AL RAS
For low ceilings
Para cielorrasos bajos
COMBO-BLADE
Combo-Blades feature two high quality finishes on one blade. Select the one that best
complements your decor, or change the style with just a flip of the blade.
NOTE: Combo-Blade finishes vary, depending upon model.
ASPAS DE DOBLE CARA
Las aspas del rotor de doble cara presentan dos superficies con un acabado de alta
calidad. Invirtiendo las aspas puede Ud. producir un efecto decorativo adaptado a
su ambiente o crear una decoración completamente nueva.
Observación: las superficies de las aspas de doble cara son distintas en función del modelo.
5
UL-ES-VectorElite-WH09
Unpack and inspect fan carefully to be certain all contents are included.
Turn off power at fuse box to avoid possible electrical shock.
1
Use metal outlet box suitable for fan support (must support 35 lbs).
Before attaching fan to outlet box, ensure the outlet box is securely
fastened by at least two points to a structural ceiling member (a loose
box will cause the fan to wobble).
2
PREPARING FOR INSTALLATION
ANTES DE LA INSTALACIÓN
Quite el envoltorio e inspeccione detenidamente el ventilador para verificar
que todas las piezas estén incluidas. Apague la alimentación en la caja de
fusibles para evitar la posibilidad de descarga eléctrica.
Use una caja de embutir de metal adecuada para soportar un ventilador
(debe soportar 35 libras). Antes de fijar el ventilador a la caja de embutir
asegúrese de que la misma esté fijada de manera segura en por lo menos
dos puntos a un miembro estructural del cielo raso (una caja suelta haría
que el ventilador oscile).
6
UL-ES-VectorElite-WH09
MOUNTING BRACKET INSTALLATION
INSTALACIÓN CON SOPORTE DE MONTAJE
3
Remove the screws and star washers from the two mating holes (1) on the canopy. Loosen (do not remove) the screws in the mating slots (2) on the canopy.
Rotate the mounting bracket counter-clockwise and remove from the canopy.
Quite los tornillos y las dos arandelas en estrella de los dos orificios coincidentes (1) del dosel. Afloje (no quite) los tornillos de las ranuras coincidentes (2) del dosel.
Gire el soporte de montaje en sentido contrario a las agujas del reloj y extráigalo del dosel.
2
1
1
2
7
UL-ES-VectorElite-WH09
Install blade to blade bracket using three blade screws as shown.
Instale el aspa a la abrazadera para aspa usando tres tornillos para aspa
como se muestra.
5
BLADE INSTALLATION
INSTALACIÓN DE LAS PALETAS
MOUNTING BRACKET INSTALLATION
INSTALACIÓN CON SOPORTE
DE MONTAJE
Install mounting bracket to outlet box in ceiling using the screws and
washers provided with the outlet box.
Instale el soporte de montaje a la caja de embutir del cielorraso con la
tornillería suministrada con la caja de embutir.
4
8
UL-ES-VectorElite-WH09
7
Choose a MOUNTING OPTION
Elija una OPCIÓN DE MONTAJE
FLUSH MOUNT OPTION
If flush mount option is selected, proceed to page 9, step 8.
OPCIÓN DE INSTALACIÓN AL RAS
Si elige la opción de montaje al ras,
proceda a la página 9, paso 8.
NORMAL DOWNROD OPTION
If installing downrod supplied with fan, proceed to page 10, step 10.
OPCIÓN CON VARILLA VERTICAL PARA CIELORRASO NORMAL
Si instala la varilla vertical incluida con el ventilador,
proceda a la página 10, paso 10.
EXTENDED DOWNROD OPTION
If installing with longer downrod than supplied with fan, proceed to page 10, step 11.
OPCIÓN CON VARILLA VERTICAL MÁS LARGA
Si instala una varilla vertical más larga que la que se incluye con el
ventilador, proceda a la página 10, paso 11.
Install blade to motor by inserting motor screws into blade holder and motor
pad (see inset). Insert blade holder between upper cover and motor. Align
holes in motor, blade holder and upper cover and tighten motor screws.
Instale la paleta en el motor insertando los tornillos del motor en el
soporte de la paleta y la almohadilla para el motor (consulte el recuadro).
Inserte el soporte de la paleta entre la cubierta superior y el motor.
Alinee los orificios del motor, el soporte de la paleta y la cubierta
superior y apriete los tornillos del motor.
6
BLADE INSTALLATION
INSTALACIÓN DE LAS PALETAS
MOUNTING OPTIONS
OPCIONES DE MONTAJE
99
UL-ES-VectorElite-WH09
FLUSH MOUNT OPTION
OPCIÓN DE INSTALACIÓN AL RAS
8
Guide motor wires through the base of the canopy as shown and attach canopy
directly to top of motor housing with flush mount screws and lock washers
provided. Tighten screws securely.
Deslice los cables del motor a través de la base del dosel como se indica y fije el
dosel directamente sobre el alojamiento del motor con los tornillos de montaje al
ras y las arandelas de presión incluidas. Apriete los tornillos asegurándolos.
9
For flush mount option, raise fan assembly and place onto hook from mounting
bracket into a closed hole on the canopy. This will allow for hands free wiring.
PROCEED DIRECTLY TO PAGE 14 FOR WIRING OPTIONS.
Para la opción de montaje al ras, levante el montaje del ventilador,
colóquelo sobre el gancho de la placa de montaje y cuélguelo en uno de
los agujeros cerrados del dosel. De este modo, tendrá las dos manos libres
para hacer el cableado. PARA LAS OPCIONES DE CABLEADO,
PROCEDA DIRECTAMENTE A LA PÁG. 14.
10
UL-ES-VectorElite-WH09
10
2
1
3
Feed motor lead wires through downrod/canopy assembly and insert downrod into downrod yoke.
Make sure to align hole in downrod with the hole in downrod yoke. Install yoke cross pin (1) through
yoke and downrod. Insert clamp pin (2) into cross pin until it snaps into place. Tighten set screws (3) in
yoke. PROCEED TO PAGE 13, STEP 15.
Pase los hilos conductores del motor a través de la varilla vertical/conjunto del dosel e inserte la
varilla vertical en la horquilla de la misma. Aserese de que el orificio de la varilla vertical y el de
la horquilla de la varilla vertical estén alineados. Instale el pasador transversal de la horquilla (1)
pasándolo por la horquilla y la varilla vertical. Inserte el pasador de fijación (2) en el pasador trans
versal hasta que escuche un chasquido que indique que está en la posición adecuada. Ajuste los
tornillos de fijación (3) en la horquilla. PROCEDA A LA PÁG. 13, PASO 15.
11
Loosen downrod ball (1) from downrod (2) by removing set screw (3).
Afloje la esfera de la varilla vertical (1) de la varilla vertical (2)
quitando el tornillo (3).
2
3
1
EXTENDED DOWNROD OPTION
OPCIÓN CON VARILLA
VERTICAL MÁS LARGA
NORMAL DOWNROD OPTION
OPCIÓN CON VARILLA VERTICAL
PARA CIELORRASO NORMAL
11
UL-ES-VectorElite-WH09
EXTENDED DOWNROD OPTION
OPCIÓN CON VARILLA VERTICAL MÁS LARGA
12
Slide downrod ball (1) off of downrod and remove pin (2).
Deslice la esfera de la varilla vertical (1) hasta separarla de la
varilla vertical y quite el pasador (2).
2
1
13
Re-install pin into extended downrod, and slide downrod ball up to the top of the downrod. Re-install
set screw to secure ball to downrod. Note: Some extended downrods have a pre-drilled set-screw hole.
If a pre-drilled hole is present in the extended downrod, tighten the set screw into the pre-drilled hole
in the extended downrod. If no pre-drilled hole exists in the extended downrod, tighten the set screw
against the downrod to secure the downrod ball.
Vuelva a instalar el pasador en la varilla vertical más larga y deslice la esfera de la varilla hasta el
extremo superior de la misma. Vuelva a insertar el tornillo de fijación para asegurar la esfera a la
varilla vertical. Nota: Algunas varillas verticales más largas tienen un agujero previamente perforado
para el tornillo. Si la varilla vertical más larga tiene un agujero previamente perforado, ajuste el
tornillo en el agujero previamente perforado de la varilla vertical más larga. Si la varilla vertical
más larga no tiene un agujero previamente perforado, ajuste el tornillo sobre la varilla vertical para
asegurar la esfera de la misma.
12
UL-ES-VectorElite-WH09
14
Feed motor lead wires through downrod/canopy assembly and insert downrod into downrod yoke. Make sure to align hole in downrod with the hole in downrod yoke.
Install yoke cross pin (1) through yoke and downrod. Insert clamp pin (2) into cross pin until it snaps into place. Tighten set screws (3) in yoke.
Pase los hilos conductores del motor a tras de la varilla vertical/conjunto del dosel e inserte la varilla vertical en la horquilla de la misma. Asegúrese de que el orificio
de la varilla vertical y el de la horquilla de la varilla vertical estén alineados. Instale el pasador transversal de la horquilla (1) pandolo por la horquilla y la varilla
vertical. Inserte el pasador de fijacn (2) en el pasador transversal hasta que escuche un chasquido que indique que está en la posición adecuada. Ajuste los
tornillos de fijación (3) en la horquilla.
EXTENDED DOWNROD OPTION
OPCIÓN CON VARILLA VERTICAL MÁS LARGA
2
1
3
13
UL-ES-VectorElite-WH09
MOUNTING
MONTAJE
16
With bracket holding fan assembly, make electrical connections using the
following step for wiring instructions.
Con la pieza de montaje sujetando el conjunto del ventilador, haga las
conexiones eléctricas de acuerdo a las siguientes instrucciones de cableado.
15
1
2
Carefully lift fan assembly onto mounting bracket. Rotate fan until notch
on downrod ball (1) engages the ridge on the mounting bracket (2). This
will allow for hands free wiring.
Levante con cuidado el conjunto del ventilador hasta el soporte de montaje.
Gire el ventilador hasta que la muesca de la bola de la varilla vertical (1)
calce sobre la saliente del soporte de montaje (2). De este modo, tendrá las
dos manos libres para hacer el cableado.
14
UL-ES-VectorElite-WH09
WIRING OPTIONS
OPCIÓN DE CABLEADO
18
White (common)
Black (hot)
Blue* (hot)
Main (ground)
White (common)
Fan Switch (hot)
Light Switch (hot)
Green (ground)
From Fan: From House:
(connect)
(connect)
(connect)
(connect)
*Attach blue wire only if attaching light kit with fan.
Wall Control
Follow diagram above to make wiring connections for wall control operation.
17
White (common)
Black (hot)
Blue* (hot)
Main (ground)
White (common)
Black (hot)
Green (ground)
From Fan: From House:
(connect)
(connect)
(connect)
*Attach blue wire only if attaching light kit with fan.
Follow diagram above to make wiring connections for fan pull chain control.
PULL CHAIN WIRING OPTION
WALL CONTROL WIRING OPTION
Blanco (común)
Negro (vivo)
Azul* (vivo)
Principal (tierra)
Blanco (común)
Interruptor del ventilador (vivo)
Interruptor de la luz (vivo)
Verde (de tierra)
Del Ventilador: De La Casa:
(conectar)
(conectar)
(conectar)
(conectar)
*Conecte el cable azul sólo si conecta un juego de luces al ventilador.
Control de pared
Siga las instrucciones del diagrama anterior para hacer las conexiones de
cableado para el ventilador con control de pared.
Blanco (común)
Negro (vivo)
Azul* (vivo)
Principal (tierra)
Blanco (común)
Negro (vivo)
Verde (de tierra)
Del Ventilador: De La Casa:
(conectar)
(conectar)
(conectar)
*Conecte el cable azul sólo si conecta un juego de luces al ventilador.
Siga las instrucciones del diagrama anterior para hacer las conexiones de
cableado para el ventilador controlado con cadenilla de tiro.
OPCIÓN DE CABLEADO PARA CADENILLA DE TIRO
OPCIÓN DE CABLEADO PARA CONTROL DE PARED
15
UL-ES-VectorElite-WH09
SECURE TO CEILING
ASEGURE EL VENTILADOR AL CIELORRASO
The canopy has two mating slots (1) and two mating holes (2). Position both slots on canopy directly under and in line with two screws in the mounting bracket (3). Lift
the canopy, allowing the two screws and star wahers to slide into the mating slots. Rotate the canopy clockwise until both screws from the mounting bracket drop into the
slot recesses. Tighten screws securely. Install two screws and star washers into the mating holes of the canopy and tighten to secure the canopy to the mounting bracket.
El dosel tiene dos ranuras coincidentes (1) y dos orificios coincidentes (2). Coloque ambas ranuras del dosel directamente abajo y en línea con los dos tornillos del soporte
de montaje (3). Eleve el dosel, permitiendo que los dos tornillos y las arandelas en estrella se deslicen dentro de las ranuras. Gire el dosel en sentido horario hasta que
ambos tornillos del soporte de montaje caigan adentro de las ranuras. Apriete los tornillos asegurándolos. Instale los dos tornillos y las arandelas en estrella en los orificios
coincidentes del dosel y ajústelos para asegurar el dosel al soporte de montaje.
19
1
3
2
For flush mount fans, carefully lift fan from the mounting bracket, making sure not to break any wire connections.
For downrod fans, slide the canopy up to the mounting bracket.
Para ventiladores de instalación al ras, levante con cuidado el ventilador del soporte de montaje asegurándose de que no interrumpa ninguna conexn de los cables.
Para ventiladores con varilla vertical, deslice el dosel hacia arriba hasta el soporte de montaje.
16
UL-ES-VectorElite-WH09
LIGHT FIXTURE INSTALLATION
INSTALACIÓN DEL ARTEFACTO LUMINOSO
Remove the spot head cover ring by twisting counterclockwise. Save it for
later use.
Quite el anillo de la cubierta de la lámpara direccional girando en sentido
contrahorario. Guárdela para usarla más tarde.
20
21
Install light bulbs.
Instale las bombillas de luz.
17
UL-ES-VectorElite-WH09
Line up the "L" slot (1) with the dent on spot head (2), push the
cover into the spot head and twist the cover clockwise.
Alinee la ranura en forma de “L” (1) con la marca en el alojamiento
de la lámpara direccional (2), empuje la cubierta hacia el interior
del alojamiento de la lámpara direccional y gire la cubierta en
sentido horario.
22
Assemble decorative fob and extension chains from hardware bag to fan pull
chains by inserting end of chain into chain coupling. Confirm chains are held by
lightly pulling both chains in coupling.
Sujetar las cadenas largas de tiro con las piezas finales correspondientes, a las
cadenas del ventilador, introduciendo el extremo de la cadena larga en la pieza
de unión. Asegúrese de que las cadenas están bien sujetas, tirando ligeramente
de ambas cadenas en la pieza de unión.
23
2
1
18
UL-ES-VectorElite-WH09
Operation
Turn on the power and check operation of fan. The pull chain controls the fan speeds as follows: 1 pull - high; 2 pulls - medium; 3 pulls - low; 4 pulls - off.
Speed settings for warm or cool weather depend on factors such as room size, ceiling height, number of fans and so on. The slide switch controls direction, forward or reverse.
Warm weather - (Forward) Fan turns counterclockwise direction. A downward air flow creates a cooling effect as shown in illustration A.
This allows you to set your air conditioner on a higher temperature setting without affecting your comfort.
Cool weather - (Reverse) Fan turns clockwise direction. An upward airflow moves warm air off the ceiling area as shown in illustration B.
This allows you to set your heating unit on a lower setting without affecting your comfort. (Please however refer to point 10 in Safety Tips when operating in this position.)
NOTE: Turn off and wait for fan to stop before changing the setting of the forward/reverse slide switch.
Maintenance
1. Because of the fan’s natural movement, some connections may become loose. Check the support connections, brackets, and blade attachments twice a year.
Make sure they are secure.
2. Clean your fan periodically to help maintain its new appearance over the years. Do not use water when cleaning.
This could damage the motor, or the wood, or possibly cause electrical shock.
3. Use only a soft brush or lint-free cloth to avoid scratching the finish. The plating is sealed with a lacquer coating to minimize discoloration or tarnishing.
4. There is no need to oil your fan. The motor has permanently lubricated bearings.
OPERATION AND MAINTENANCE
19
UL-ES-VectorElite-WH09
Operación
Encienda el ventilador y verifique su funcionamiento. La cadenilla de tiro controla las velocidades del ventilador de la siguiente manera:
1 jalón – rápida; 2 jalones - mediana; 3 jalones - lenta; 4 jalones - apagado.
Las velocidades para clima cálido o frío dependen de factores como el tamaño de la habitación, la altura del ventilador,
el número de ventiladores, etc. El conmutador de tipo deslizante controla la dirección, hacia adelante o hacia atrás.
Clima cálido - (Adelante) El ventilador gira en sentido contrahorario. Una corriente de aire descendente crea un efecto refrescante como lo indica la ilustración A.
Esto le permite ajustar el aire acondicionado a una temperatura más alta sin que afecte su comodidad.
Clima frío - (Atrás) El ventilador gira en sentido de las agujas del reloj. Una corriente de aire ascendente aleja el aire caliente del área del ventilador de techo como
lo indica la ilustración B. Esto le permite ajustar la calefacción a un nivel más bajo sin que afecte su comodidad. (De todos modos, por favor consulte el punto 10 de las Sugerencias de seguri-
dad cuando utilice el ventilador en esta posición.)
NOTA: Apague el ventilador y espere a que se detenga antes de cambiar la dirección de adelante/atrás con el conmutador de tipo deslizante.
Mantenimiento
1. El movimiento natural del ventilador podría hacer que se aflojen algunas conexiones. Verifique las conexiones de soporte, las piezas de fijación y los accesorios de las paletas
dos veces al año. Cerciórese de que estén aseguradas.
2. Limpie el ventilador periódicamente para ayudar a mantener su apariencia nueva con el correr de los años. No use agua para limpiarlo, ya que podría dañar el motor o la
madera o causar descarga eléctrica.
3. Use sólo un cepillo blando o un trapo sin pelusa para no rayar el acabado. El enchapado está sellado con una capa de laca para minimizar la decoloración o pérdida del brillo.
4. No hay necesidad de aceitar el ventilador. El motor tiene cojinetes de lubricación permanente.
OPERACIÓN Y MANTENIMIENTO
20
UL-ES-VectorElite-WH09
TROUBLESHOOTING GUIDE
If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation, or wiring. In some cases, these
installation errors may be mistaken for defects. If you experience any faults, please check this Trouble Shooting Chart. If a problem cannot be
remedied, please consult with your authorized electrician and do not attempt any electrical repairs yourself.
TROUBLE
1. If fan does not start:
2. If fan sounds noisy:
3. If fan wobbles:
4. If light does not work:
SUGGESTED REMEDY
1. Check main and branch circuit fuses or circuit breakers.
2. Check wire connections as performed in step #17 or #18 of installation.
CAUTION: Make sure main power is turned off.
3. Make sure forward/reverse switch is firmly in up or down position.
Fan will not operate when switch is in the middle.
4. If the fan still will not start, contact a qualified electrician.
Do not attempt to troubleshoot internal electrical connections yourself.
1. Check to make sure all screws in motor housing are snug (not over tightened).
2. Check to make sure the screws which attach the fan blade holder to the motor are tight.
3. Some fan motors are sensitive to signals from Solid State variable speed controls.
DO NOT USE a Solid State variable speed control.
4. Allow “break-in” period of 24 hours. Most noises associated with a new fan will disappear
after this period.
All blades are weighed and grouped by weight. Natural woods vary in density which could cause
the fan to wobble even though all blades are weight-matched. The following procedures should
eliminate most of the wobble. Check for wobble after each step.
1. Check that all blades are screwed firmly into blade holders.
2. Check that all blade holders are tightened securely to motor.
3. Make sure that canopy and mounting bracket are tightened securely to ceiling joist.
4. If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can redistribute
the weight and possibly result in smoother operation.
1. Check for faulty light bulbs.
2. If light kit will still not operate, contact a qualified electrician for assistance.
NOTICE
This ‘Energy Policy Act 2005’ compliant fan includes a device
that limits the total wattage of its light fixture to 190 watts.
By installing a combination of light bulbs that exceeds 190 watts or if an
electrical surge causes the wattage to exceed 190 watts, the light fixture
will either dim the lights to 190 watts or will automatically turn off.
To restore the light levels, make sure the total wattage of the light bulbs
does not exceed 190 watts and follow the applicable directions below:
For fans with Pull Chains:
Pull the light fixture’s pull chain two times to reset the light fixture.
If the power to your fan is controlled by a toggle wall switch, it may
be necessary to turn the power off and back on at the wall switch.
For fans with Wall Controls:
Press the light button on the wall control “off” and “on”
once to reset the light fixture.
For fans with Remote Controls:
If you verify the wattage and the lights do not turn on, press the
light button on the remote control twice to reset the light fixture.
NOTE: If the procedures above do not reset the lights,
turn off the main power source, located at the breaker panel or box,
and then turn it on again.
21
UL-ES-VectorElite-WH09
GUÍA PARA SOLUCIONAR PROBLEMAS
Si tiene dificultades para hacer funcionar su nuevo ventilador, podría ser a causa del armado, instalación o cableado incorrectos. En algunos
casos, estos errores de instalación podrían ser confundidos con defectos. Si experimenta alguna falla, consulte esta guía para solucionar
problemas. Si no puede solucionar el problema, consulte a un electricista autorizado y no intente reparar conexiones eléctricas.
PROBLEMA
1. Si el ventilador no arranca:
2. Si el ventilador es ruidoso:
3. Si el ventilador oscila:
4. Si la luz no funciona:
SOLUCIÓN SUGERIDA
1. Compruebe los fusibles o disyuntores principales y del circuito derivado.
2. Compruebe el cableado del bloque de terminales como lo hizo en el paso No. 17 ó 18 de la
instalación. ADVERTENCIA: Asegúrese de que la alimentación principal esté apagada.
3. Asegúrese de que el interruptor de marcha adelante/atrás esté firmemente en su posición.
El ventilador no funcionará si el interruptor está en el medio.
4. Si el ventilador no arranca, póngase en contacto con un electricista calificado. No intente
reparar conexiones eléctricas internas.
1. Compruebe para asegurarse de que todos los tornillos del alojamiento del motor estén ajustados
(no los apriete demasiado).
2. Compruebe para asegurarse de que los tornillos que fijan el soporte de la paleta del ventilador
al motor estén apretados.
3. NO USE un control de velocidad variable de estado sólido.
4. Permita el "rodaje" del ventilador durante un período de 24 horas. La mayoría de los ruidos
asociados con el ventilador nuevo desaparecerán después de este período.
Todas las paletas se pesan y agrupan sen el peso. Las maderas naturales varían en densidad y podrían hacer
que el ventilador oscile n cuando todas las paletas estén agrupadas por peso. Los siguientes procedimientos
deberían eliminar la mayoría de los problemas de oscilación. Verifique la oscilación después de cada paso.
1. Verifique que todas las paletas estén firmemente atornilladas a los soportes de las paletas.
2. Verifique que todos los soportes de las paletas estén firmemente aseguradas al motor.
3. Asegúrese de que el dosel y el soporte de montaje estén firmemente asegurados a la viga
del cielorraso.
4. Si la oscilación de la paleta sigue siendo visible, es posible que al intercambiar dos paletas adyacentes
(lado a lado) se redistribuya el peso y el funcionamiento sea más suave.
1. Compruebe si hay lámparas defectuosas.
2. Si el conjunto de luces no funciona, póngase en contacto con un electricista calificado.
AVISO
Este ventilador, que cumple con las exigencias del 'Energy Policy Act 2005',
incluye un accesorio que limita el vataje total de su lámpara a 190 vatios.
Si usted instala una combinación de bombillas que sobrepasen
los 190 vatios o si un sobrevoltaje hace que el voltaje sea superior
a 190 vatios, la lámpara regulará la intensidad a 190 vatios o se apagará.
Para restablecer el nivel de luminosidad, asegúrese que el vataje total
de las bombillas no sobrepase los 190 vatios y siga las indicaciones
aplicables a continuación:
Para ventiladores con Cadenilla de tiro:
Jale la cadenilla de la lámpara dos veces para reiniciarla. Si la energía
de su ventilador se controla con un interruptor en la pared,
puede ser necesario apagar el interruptor y luego encenderlo.
Para ventiladores con Control de pared:
Presione el botón en la pared una vez para apagar y una vez
para encender, para así reiniciar la lámpara.
Para ventiladores con Control remoto:
Si verifica el vataje y la luz no enciende, presione el botón para
la luz en el control remoto dos veces para reiniciar la lámpara.
NOTA: Si los procedimientos mencionados no reinician la lámpara,
desconecte la fuente principal de energía, ubicada
en el panel o caja de interruptor, y vuélvala a conectar.
22
UL-ES-VectorElite-WH09
23
UL-ES-VectorElite-WH09
# Description
1 . . . . . . . . . . . . . . . . . . Mounting Bracket
2 . . . . . . . . . . . . . . . . . . Blade Bracket
3 . . . . . . . . . . . . . . . . . . Blade
4 . . . . . . . . . . . . . . . . . . Fan Speed Switch
5 . . . . . . . . . . . . . . . . . . Light Control Switch
6 . . . . . . . . . . . . . . . . . . Capacitor
7 . . . . . . . . . . . . . . . . . . Hardware Pack
No. Descripción
1 . . . . . . . . . . . . . . . . . . Soporte de montaje
2 . . . . . . . . . . . . . . . . . . Soporte para paleta
3 . . . . . . . . . . . . . . . . . . Paleta
4 . . . . . . . . . . . . . . . . . . Interruptor de control de
. . . . . . . . . . . . . . . . . . . velocidad para ventilador
5 . . . . . . . . . . . . . . . . . . Interruptor de control de luz
6 . . . . . . . . . . . . . . . . . . Condensador
7 . . . . . . . . . . . . . . . . . . Tornillería
1
3
7
6
4
5
2
PARTS LIST
LISTA DE REPUESTOS
UL-ES-VectorElite-WH09
Westinghouse Lighting Corporation
12401 McNulty Road
Philadelphia, PA 19154 U.S.A.
Westinghouse Lighting Corporation,
a Westinghouse Electric Corporation licensee
is a registered trademark of
Westinghouse Electric Corporation
Made in China
© 2009
Westinghouse Lighting Corporation
Westinghouse Lighting Corporation
12401 McNulty Road
Philadelphia, PA 19154 U.S.A.
Westinghouse Lighting Corporation,
titular de la licencia de Westinghouse Electric Corporation
es una marca registrada de
Westinghouse Electric Corporation
Fabricado en
China
© 2009
Westinghouse Lighting Corporation
1 / 1

Westinghouse Outdoor Ceiling Fan UL-ES-VectorElite-WH09 Manual de usuario

Categoría
Ventiladores domésticos
Tipo
Manual de usuario
Este manual también es adecuado para