Tripp Lite 500DR Manual de usuario

Categoría
Unidades de suministro de energía
Tipo
Manual de usuario

Este manual también es adecuado para

New Specifications
OmniPro 300 OmniPro 500 OmniPro 500DR
Output Capacity (VA/Watts): 300/180 500/300 500/300
Battery Runtime (Half Load/
Full Load) Minutes: 17/5 17/5 17/5
Battery Recharge Time: 2-4 hrs. 2-4 hrs. 2-4 hrs.
Approvals: UL, cUL, NOM UL, cUL, NOM UL, cUL, NOM
Modem/Fax Protection
(starts at 260V): 1 line 1 line
OmniPro 825 OmniSmart 500 PNP OmniSmart 700 PNP
Output Capacity (VA/Watts): 825/570 500/300 700/425
Battery Runtime (Half Load/
Full Load) Minutes: 26/9 17/5 17/5
Battery Recharge Time: 2-4 hrs. 2-4 hrs. 2-4 hrs.
Approvals: UL, cUL, NOM UL, cUL, NOM UL, cUL, NOM
Modem/Fax Protection
(starts at 260V): 1 line 2 lines
ALL MODELS: Input Voltage/Frequency (120V/60 Hz); On-Line Input Voltage Range (75 - 147 volts); Voltage-Regulated Output Voltage
Range (120V +6% / -12%); On Battery Output Voltage Range (120V ±5%); Output Waveform Line Mode (filtered sinewave); Output
Waveform Battery Mode (PWM sine wave); AC Surge Suppression (exceeds IEEE 587 Cat. A & B standards); AC Noise Attenuation
(>40 dB); AC Protection Modes (H to N, H to G, N to G).
1111 W. 35th Street
Chicago, IL 60609 USA
Customer Support: (773) 869-1234
www.tripplite.com
Owner's Manual Addendum
OMNISMART
OMNIPRO
Line-Interactive UPS Systems (120V)
Especificaciones Nuevos
OmniPro 300 OmniPro 500 OmniPro 500DR
Capacidad de Salida (VA/Vatios): 300/180 500/300 500/300
Tiempo de Operación de la Batería
(Media Carga/Plena Carga) Min.: 17/5 17/5 17/5
Tiempo de Recarga
de la Batería: 2-4 horas 2-4 horas 2-4 horas
Certificaciones: UL, cUL, NOM UL, cUL, NOM UL, cUL, NOM
Protección para Módem / Fax
(comienza a 260 voltios): 1 línea 1 línea
OmniPro 825 OmniSmart 500 PNP OmniSmart 700 PNP
Capacidad de Salida (VA/Vatios): 825/570 500/300 700/425
Tiempo de Operación de la Batería
(Media Carga/Plena Carga) Min.: 26/9 17/5 17/5
Tiempo de Recarga
de la Batería: 2-4 horas 2-4 horas 2-4 horas
Certificaciones: UL, cUL, NOM UL, cUL, NOM UL, cUL, NOM
Protección para Módem / Fax
(comienza a 260 voltios): 1 línea 2 líneas
TODOS LOS MODELOS: Voltaje/Frecuencia de Entrada (120V/60Hz); Rango de Voltaje de Entrada En Línea (75-147V); Rango de Voltaje de
Salida En Línea (120V +6% / -12%); Rango del Voltaje de Salida En Batería (120V ±5%); Onda de Salida En Línea (sinusoidal filtrada); Onda
de Salida En Batería (modulada en ancho de pulso); Supresión de Sobretensiones Transitorias de CA (excede las normas de IEEE 587
Categorías A y B); Atenuación de Ruidos de CA (>40 dB); Modos de Protección de CA (Positivo a Neutro, Positivo a Tierra y Neutro a Tierra).
120V OmniSmart OmniPro Addendum.p65 11/11/99, 12:30 PM1

Transcripción de documentos

Owner's Manual Addendum ™ OMNISMART OMNIPRO™ 1111 W. 35th Street Chicago, IL 60609 USA Customer Support: (773) 869-1234 www.tripplite.com Line-Interactive UPS Systems (120V) New Specifications Output Capacity (VA/Watts): Battery Runtime (Half Load/ Full Load) Minutes: Battery Recharge Time: Approvals: Modem/Fax Protection (starts at 260V): Output Capacity (VA/Watts): Battery Runtime (Half Load/ Full Load) Minutes: Battery Recharge Time: Approvals: Modem/Fax Protection (starts at 260V): OmniPro 300 OmniPro 500 OmniPro 500DR 300/180 500/300 500/300 17/5 2-4 hrs. UL, cUL, NOM 17/5 2-4 hrs. UL, cUL, NOM 17/5 2-4 hrs. UL, cUL, NOM — 1 line 1 line OmniPro 825 OmniSmart 500 PNP OmniSmart 700 PNP 825/570 500/300 700/425 26/9 2-4 hrs. UL, cUL, NOM 17/5 2-4 hrs. UL, cUL, NOM 17/5 2-4 hrs. UL, cUL, NOM — 1 line 2 lines ALL MODELS: Input Voltage/Frequency (120V/60 Hz); On-Line Input Voltage Range (75 - 147 volts); Voltage-Regulated Output Voltage Range (120V +6% / -12%); On Battery Output Voltage Range (120V ±5%); Output Waveform Line Mode (filtered sinewave); Output Waveform Battery Mode (PWM sine wave); AC Surge Suppression (exceeds IEEE 587 Cat. A & B standards); AC Noise Attenuation (>40 dB); AC Protection Modes (H to N, H to G, N to G). Especificaciones Nuevos OmniPro 300 Capacidad de Salida (VA/Vatios): 300/180 Tiempo de Operación de la Batería (Media Carga/Plena Carga) Min.: 17/5 Tiempo de Recarga de la Batería: 2-4 horas Certificaciones: UL, cUL, NOM Protección para Módem / Fax (comienza a 260 voltios): — OmniPro 825 Capacidad de Salida (VA/Vatios): 825/570 Tiempo de Operación de la Batería (Media Carga/Plena Carga) Min.: 26/9 Tiempo de Recarga de la Batería: 2-4 horas Certificaciones: UL, cUL, NOM Protección para Módem / Fax (comienza a 260 voltios): — OmniPro 500 OmniPro 500DR 500/300 500/300 17/5 17/5 2-4 horas UL, cUL, NOM 2-4 horas UL, cUL, NOM 1 línea 1 línea OmniSmart 500 PNP OmniSmart 700 PNP 500/300 700/425 17/5 17/5 2-4 horas UL, cUL, NOM 2-4 horas UL, cUL, NOM 1 línea 2 líneas TODOS LOS MODELOS: Voltaje/Frecuencia de Entrada (120V/60Hz); Rango de Voltaje de Entrada En Línea (75-147V); Rango de Voltaje de Salida En Línea (120V +6% / -12%); Rango del Voltaje de Salida En Batería (120V ±5%); Onda de Salida En Línea (sinusoidal filtrada); Onda de Salida En Batería (modulada en ancho de pulso); Supresión de Sobretensiones Transitorias de CA (excede las normas de IEEE 587 Categorías A y B); Atenuación de Ruidos de CA (>40 dB); Modos de Protección de CA (Positivo a Neutro, Positivo a Tierra y Neutro a Tierra). 120V OmniSmart OmniPro Addendum.p65 1 11/11/99, 12:30 PM
  • Page 1 1
  • Page 2 2

Tripp Lite 500DR Manual de usuario

Categoría
Unidades de suministro de energía
Tipo
Manual de usuario
Este manual también es adecuado para