Wiring ProcedureWiring Procedure
Wiring ProcedureWiring Procedure
Wiring Procedure
WARNING:WARNING:
WARNING:WARNING:
WARNING:
TO BE INSTALLED AND/OR USED IN
ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND
REGULATIONS.
WARNING:WARNING:
WARNING:WARNING:
WARNING:
IF YOU ARE NOT SURE ABOUT ANY PART OF
THESE INSTRUCTIONS, CONSULT A QUALIFIED ELECTRICIAN.
WARNING: WARNING:
WARNING: WARNING:
WARNING: TO AVOID FIRE, SHOCK OR DEATH; UNPLUG
CORD OR TURN OFF POWER AT CIRCUIT BREAKER OR FUSE
AND TEST THAT POWER IS OFF BEFORE WIRING!
CAUTION:CAUTION:
CAUTION:CAUTION:
CAUTION:
USE THIS DEVICE ONLY WITH COPPER OR
COPPER CLAD WIRE. WITH ALUMINUM WIRE USE DEVICES
MARKED CO/ALR OR CU/AL.
TO INSTALL:TO INSTALL:
TO INSTALL:TO INSTALL:
TO INSTALL:
1.1.
1.1.
1. Loosen front assembly screws and separate device husk from
module
(see General Wiring Diagram)(see General Wiring Diagram)
(see General Wiring Diagram)(see General Wiring Diagram)
(see General Wiring Diagram). If needed, back out cord
clamp screws to insert cord through husk.
2.2.
2.2.
2. Strip cord jacket and individual conductors according to
appropriate wire stripping diagram
or strip gage on device.
NOTE: NOTE:
NOTE: NOTE:
NOTE: Standard devices require different stripping than Angle
devices.
3.3.
3.3.
3. Connect Wires:
NOTE:NOTE:
NOTE:NOTE:
NOTE: Standard, Metal Cup, and Plastic Cup devices can be
wired either by conventional methods (wire stripping only) or with
the attachment of non-insulated spade lugs to the stripped
conductors
(see General Wiring Diagram)(see General Wiring Diagram)
(see General Wiring Diagram)(see General Wiring Diagram)
(see General Wiring Diagram).
NOTE: NOTE:
NOTE: NOTE:
NOTE: Terminal screw polarity is designated by screw color.
Fully back out terminal clamps. Twist all strands of each
conductor tightly together
(DO NOT TIN CONDUCTORS(DO NOT TIN CONDUCTORS
(DO NOT TIN CONDUCTORS(DO NOT TIN CONDUCTORS
(DO NOT TIN CONDUCTORS). Insert
conductors into proper wire well as per wiring chart, and tighten
terminal screws firmly to 10-12 in.-lbs.
For Spade Lug wiring, attach proper size lug (#18-#14) to
conductors and insert into proper wire well as per wiring chart,
and tighten terminal screws firmly to 10-12 in.-lbs.
11
11
1
CAUTION:CAUTION:
CAUTION:CAUTION:
CAUTION:
COPPER CONDUCTORS OR SPADE LUGS MUST
BE FULLY INSERTED INTO WIRE WELLS. CUT OFF ANY
STRAY STRANDS. TERMINAL CLAMPS MUST TIGHTEN
ONTO BARE CONDUCTORS OR SPADE LUGS ONLY, NOT
INSULATION.
NOTE: NOTE:
NOTE: NOTE:
NOTE: For Angle devices, refer to General Wiring Diagram for
conductor placement.
4.4.
4.4.
4. Re-attach device husk to module by aligning either of the
assembly screws to the mounting posts
(devices are not(devices are not
(devices are not(devices are not
(devices are not
keyed)keyed)
keyed)keyed)
keyed). Tighten assembly screws to 10-12 in.-lbs. Firmly secure
cord clamp on to husk by alternately tightening screws to
10 in.-lbs.
DO NOT OVERTIGHTEN.DO NOT OVERTIGHTEN.
DO NOT OVERTIGHTEN.DO NOT OVERTIGHTEN.
DO NOT OVERTIGHTEN.
NOTE:NOTE:
NOTE:NOTE:
NOTE: Refer to Cable Range Chart for cabling sizes.
5.5.
5.5.
5. For Panel Mounting: Cut opening per appropriate diagram and
mount using two (2) #6-32 screws provided.
Refer to NEC tables, article 400 for proper wire type and size forRefer to NEC tables, article 400 for proper wire type and size for
Refer to NEC tables, article 400 for proper wire type and size forRefer to NEC tables, article 400 for proper wire type and size for
Refer to NEC tables, article 400 for proper wire type and size for
your application and load.your application and load.
your application and load.your application and load.
your application and load.
EspañolEspañol
EspañolEspañol
Español
Clavijas y Conectores Pequeños Estándar YClavijas y Conectores Pequeños Estándar Y
Clavijas y Conectores Pequeños Estándar YClavijas y Conectores Pequeños Estándar Y
Clavijas y Conectores Pequeños Estándar Y
c/Seguro de 2 y 3 Alambres 15A-125VCA / 250VCAc/Seguro de 2 y 3 Alambres 15A-125VCA / 250VCA
c/Seguro de 2 y 3 Alambres 15A-125VCA / 250VCAc/Seguro de 2 y 3 Alambres 15A-125VCA / 250VCA
c/Seguro de 2 y 3 Alambres 15A-125VCA / 250VCA
Procedimiento de CableadoProcedimiento de Cableado
Procedimiento de CableadoProcedimiento de Cableado
Procedimiento de Cableado
ADVERTENCIA:ADVERTENCIA:
ADVERTENCIA:ADVERTENCIA:
ADVERTENCIA: PARA INSTALARSE Y/O USARSE DE
ACUERDO CON LOS CODIGOS ELECTRICOS Y NORMAS
APROPIADOS.
ADVERTENCIA:ADVERTENCIA:
ADVERTENCIA:ADVERTENCIA:
ADVERTENCIA:
SI USTED NO ESTÁ SEGURO ACERCA DE
ALGUNA DE LAS PARTES DE ESTAS INSTRUCCIONES,
CONSULTE A UN ELECTRICISTA CALIFICADO.
ADVERTENCIA:ADVERTENCIA:
ADVERTENCIA:ADVERTENCIA:
ADVERTENCIA:
PARA EVITAR DESCARGA ELECTRICA,
FUEGO, O MUERTE; DESCONECTE EL CORDON O
INTERRUMPA EL PASO DE ENERGIA MEDIANTE EL
INTERRUPTOR DE CIRCUITO O FUSIBLE. ¡ASEGURESE DE QUE
EL CIRCUITO NO ESTE ENERGIZADO ANTES DE INICIAR LA
INSTALACION!
PRECAUCION:PRECAUCION:
PRECAUCION:PRECAUCION:
PRECAUCION: USE ESTE PRODUCTO SÓLO CON CABLE DE
COBRE O REVESTIDO DE COBRE. PARA CABLE DE ALUMINIO
USE SÓLO PRODUCTOS MARCADOS CON EL SÍMBOLO CO/ALR
O CU/AL.
PARA INSTALAR:PARA INSTALAR:
PARA INSTALAR:PARA INSTALAR:
PARA INSTALAR:
1.1.
1.1.
1. Afloje los tornillos de montaje y separe el bastidor del módulo
(vea el Diagrama General de Cableado)(vea el Diagrama General de Cableado)
(vea el Diagrama General de Cableado)(vea el Diagrama General de Cableado)
(vea el Diagrama General de Cableado). Si se necesita, afloje
los tornillos de la abrazadera para pasar el cordón por el
bastidor.
2.2.
2.2.
2. Pele el forro del cordón y los conductores individuales de
acuerdo al diagrama de pelado apropiado o diagrama descrito en el
producto.
Nota:Nota:
Nota:Nota:
Nota: Los productos Estándar requieren de pelado diferente a los
productos en Angulo
3.3.
3.3.
3. Conecte los Cables:
NOTA: NOTA:
NOTA: NOTA:
NOTA: Los productos estándar, de Copa de Metal y de Copa
Plástica se pueden cablear por métodos convencionales (pelado
de cable) o con el uso de conectores no aislados con aletas
sujetadas a los conductores pelados
(vea el Diagrama General(vea el Diagrama General
(vea el Diagrama General(vea el Diagrama General
(vea el Diagrama General
de Cableadode Cableado
de Cableadode Cableado
de Cableado).
NOTA:NOTA:
NOTA:NOTA:
NOTA: La polaridad de los tornillos terminales es designada por
los colores de los tornillos.
Afloje totalmente los tornillos terminales. Tuerze todos los hilos
de cada conductor juntos y bien apretados
(NO ESTA(NO ESTA
(NO ESTA(NO ESTA
(NO ESTA
ÑÑ
ÑÑ
Ñ
E LOSE LOS
E LOSE LOS
E LOS
CONDUCTORES)CONDUCTORES)
CONDUCTORES)CONDUCTORES)
CONDUCTORES). Inserte los conductores en los orificios
apropiados de acuerdo a la tabla de cableado y apriete los
tornillos terminales a una tensión de 10-12 in.-lb.
Para cableado de conectores con aletas, sujete el conector de
tamaño apropiado a los conductores (#18-#14) e insertelos en
los orificios apropiados de acuerdo a la tabla de cableado y
apriete firmemente los tornillos terminales a una tensión de
10-12 in.-lb.
PRECAUCION: PRECAUCION:
PRECAUCION: PRECAUCION:
PRECAUCION: LOS CONDUCTORES DE COBRE O LOS
CONECTORES CON ALETAS DEBEN ESTAR TOTALMENTE
METIDOS EN LOS ORIFICIOS DE CABLEADO. CORTE
CUALQUIER HILO SUELTO. LAS TERMINALES SOLO DEBEN
APRETAR AL CONDUCTOR O A LOS CONECTORES, NO AL
AISLANTE.
Nota:Nota:
Nota:Nota:
Nota: Para posición del conductor en productos en Angulo, vea
el Diagrama General de Cableado.
4.4.
4.4.
4. Vuelva a montar el bastidor al módulo alineando cualquiera de
los tornillos de ensamble a los postes de montaje (
los productoslos productos
los productoslos productos
los productos
no tienen llave de guía). no tienen llave de guía).
no tienen llave de guía). no tienen llave de guía).
no tienen llave de guía). Apriete los tornillos a una tensión de
10-12 in.Lbs
. .
. .
. Asegure fírmemente la abrazadera del cordón al
bastidor apretando los tornillos alternadamente a una tensión de
10 in.-lb.
NO SOBRE APRIETE.NO SOBRE APRIETE.
NO SOBRE APRIETE.NO SOBRE APRIETE.
NO SOBRE APRIETE.
For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only)For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only)
For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only)For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only)
For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only)
1 800 405-5320 (Canada Only)1 800 405-5320 (Canada Only)
1 800 405-5320 (Canada Only)1 800 405-5320 (Canada Only)
1 800 405-5320 (Canada Only)
www.leviton.comwww.leviton.com
www.leviton.comwww.leviton.com
www.leviton.com
LIMITED 10 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit
of anyone else that this product at the time of its sale by Leviton is free of
defects in materials and workmanship under normal and proper use for ten
years from the purchase date. Leviton’s only obligation is to correct such
defects by repair or replacement, at its option, if within such ten year period
the product is returned prepaid, with proof of purchase date, and a description
of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance
Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-
2591 (In Canada send to Leviton Mfg. of Canada Ltd., 165 Hymus Blvd.,
Point Claire, (Quebec), Canada H9R 1E9). This warranty excludes and there
is disclaimed liability for labor for removal of this product or reinstallation.
This warranty is void if this product is installed improperly or in an improper
environment, overloaded, misused, opened, abused, or altered in any manner,
or is not used under normal operating conditions or not in accordance with
any labels or instructions. There are no other or implied warranties of any
kind, including merchantability and fitness for a particular purpose, but if any
implied warranty is required by the applicable jurisdiction, the duration of any
such implied warranty, including merchantability and fitness for a particular
purpose, is limited to ten years. Leviton is not liable for incidental, indirect,
special, or consequential damages, including without limitation, damage to,
or loss of use of, any equipment, lost sales or profits or delay or failure to
perform this warranty obligation. The remedies provided herein are the
exclusive remedies under this warranty, whether based on contract, tort or
otherwise.
NOTA:NOTA:
NOTA:NOTA:
NOTA: Para tamaños de cable vea la Tabla de Rango de Cable.
5.5.
5.5.
5. Para Montar a Paneles: Corte un hueco de acuerdo al diagrama
apropiado y móntelo usando los dos (2) tornillos #6-32 provistos.
Refiérase al Artículo 400 en las tablas de NEC, para usar elRefiérase al Artículo 400 en las tablas de NEC, para usar el
Refiérase al Artículo 400 en las tablas de NEC, para usar elRefiérase al Artículo 400 en las tablas de NEC, para usar el
Refiérase al Artículo 400 en las tablas de NEC, para usar el
alambre del tipo y tamaño apropiado para su aplicación y carga.alambre del tipo y tamaño apropiado para su aplicación y carga.
alambre del tipo y tamaño apropiado para su aplicación y carga.alambre del tipo y tamaño apropiado para su aplicación y carga.
alambre del tipo y tamaño apropiado para su aplicación y carga.
FrançaisFrançais
FrançaisFrançais
Français
Fiches et connecteurs verrouillables miniaturesFiches et connecteurs verrouillables miniatures
Fiches et connecteurs verrouillables miniaturesFiches et connecteurs verrouillables miniatures
Fiches et connecteurs verrouillables miniatures
standard, bifilaires ou trifilairesstandard, bifilaires ou trifilaires
standard, bifilaires ou trifilairesstandard, bifilaires ou trifilaires
standard, bifilaires ou trifilaires
15 A, 125 V c.a. / 250 V c. a.15 A, 125 V c.a. / 250 V c. a.
15 A, 125 V c.a. / 250 V c. a.15 A, 125 V c.a. / 250 V c. a.
15 A, 125 V c.a. / 250 V c. a.
Directives de câblageDirectives de câblage
Directives de câblageDirectives de câblage
Directives de câblage
AVERTISSEMENTAVERTISSEMENT
AVERTISSEMENTAVERTISSEMENT
AVERTISSEMENT
::
::
: INSTALLER OU UTILISER
CONFORMÉMENT AUX CODES DE L’ÉLECTRICITÉ EN VIGUEUR.
AVERTISSEMENT :AVERTISSEMENT :
AVERTISSEMENT :AVERTISSEMENT :
AVERTISSEMENT : À DÉFAUT DE BIEN COMPRENDRE LES
PRÉSENTES DIRECTIVES, EN TOUT OU EN PARTIE, ON DOIT
FAIRE APPEL À UN ÉLECTRICIEN QUALIFIÉ.
AVERTISSEMENTAVERTISSEMENT
AVERTISSEMENTAVERTISSEMENT
AVERTISSEMENT
::
::
:
POUR ÉVITER LES RISQUES D’INCENDIE,
DE CHOC ÉLECTRIQUE OU D’ÉLECTROCUTION, DÉBRANCHER
LE CORDON OU COUPER LE COURANT AU FUSIBLE OU AU
DISJONCTEUR ET S’ASSURER QUE LE CIRCUIT SOIT BIEN
COUPÉ AVANT DE PROCÉDER À L’INSTALLATION.
MISE EN GARDEMISE EN GARDE
MISE EN GARDEMISE EN GARDE
MISE EN GARDE
::
::
:
N’UTILISER CE DISPOSITIF QU’AVEC DU
FIL DE CUIVRE; EN PRÉSENCE DE FIL D’ALUMINIUM, UTILISER
SEULEMENT LES DISPOSITIFS PORTANT LA MARQUE CU/AL OU
CO/ALR.
INSTALLATION :INSTALLATION :
INSTALLATION :INSTALLATION :
INSTALLATION :
1.1.
1.1.
1. Desserrer les vis d’assemblage et séparer la coquille du module
(se reporter au schéma de câblage général)(se reporter au schéma de câblage général)
(se reporter au schéma de câblage général)(se reporter au schéma de câblage général)
(se reporter au schéma de câblage général). Le cas échéant,
desserrer les vis du collier de cordon pour permettre l’insertion
de ce dernier dans la coquille.
2.2.
2.2.
2. Retirer la gaine du cordon et dénuder chaque conducteur
conformément au schéma approprié ou au gabarit apparaissant
sur le dispositif.
REMARQUE :REMARQUE :
REMARQUE :REMARQUE :
REMARQUE : les fils des dispositifs standard ne
doivent pas être dénudés de la même manière que ceux des
dispositifs angulaires.
3.3.
3.3.
3. Raccorder les fils :
REMARQUE :REMARQUE :
REMARQUE :REMARQUE :
REMARQUE : les dispositifs standard, à coupelle en métal ou en
plastique, peuvent être raccordés de manière conventionnelle (fils
dénudés seulement) ou par l’entremise de bornes embrochables
non-étanche reliées à leurs fils dénudés
(se reporter au(se reporter au
(se reporter au(se reporter au
(se reporter au
schéma de câblage général)schéma de câblage général)
schéma de câblage général)schéma de câblage général)
schéma de câblage général).
REMARQUE : REMARQUE :
REMARQUE : REMARQUE :
REMARQUE : la polarité des vis de borne est indiquée par leur
couleur respective.
Desserrer complètement les vis de borne. Entortiller fermement
les extrémités dénudées de chaque conducteur
(NE PAS LES(NE PAS LES
(NE PAS LES(NE PAS LES
(NE PAS LES
ÉTAMER)ÉTAMER)
ÉTAMER)ÉTAMER)
ÉTAMER) et les insérer dans l’orifice approprié, conformément
au tableau de câblage; serrer fermement les vis en appliquant un
couple de 10 à 12 po-lb.
Si on se sert de bornes embrochables, on doit choisir le calibre
approprié (18 à 14), les fixer aux conducteurs et les insérer dans
l’orifice approprié, conformément au tableau de câblage; serrer
fermement les vis en appliquant un couple de 10 à 12 po-lb.
MISE EN GARDE :MISE EN GARDE :
MISE EN GARDE :MISE EN GARDE :
MISE EN GARDE : LES CONDUCTEURS OU LES BORNES
EMBROCHABLES DOIVENT ÊTRE COMPLÈTEMENT
INSÉRÉS DANS LES ORIFICES DE CÂBLAGE. ON DOIT
COUPER TOUS LES BRINS QUI DÉPASSENT. LES PINCES
DES BORNES DOIVENT SE REFERMER SUR LES FILS
DÉNUDÉS OU SUR LES BORNES EMBROCHABLES, NON
SUR L’ISOLANT.
REMARQUE :REMARQUE :
REMARQUE :REMARQUE :
REMARQUE : en présence de dispositifs angulaires, se reporter
au schéma de câblage général pour connaître l’emplacement des
conducteurs.
4.4.
4.4.
4. Réassembler la coquille et le module en alignant l’une ou l’autre
des vis de montage aux tiges de fixation
(le dispositif n’a pas(le dispositif n’a pas
(le dispositif n’a pas(le dispositif n’a pas
(le dispositif n’a pas
de position déterminée)de position déterminée)
de position déterminée)de position déterminée)
de position déterminée). Serrer les vis d’assemblage en
appliquant un couple de 10 à 12 po-lb. Serrer solidement le
collier sur la coquille en appliquant tour à tour à chacune des vis
un couple de 10 po-lb.
NE PAS TROP SERRERNE PAS TROP SERRER
NE PAS TROP SERRERNE PAS TROP SERRER
NE PAS TROP SERRER.
REMARQUE :REMARQUE :
REMARQUE :REMARQUE :
REMARQUE : se reporter au tableau des calibres pour connaître
la grosseur de câble à utiliser.
5.5.
5.5.
5. Montage sur panneau : découper une ouverture conformément
au schéma approprié, et fixer le dispositif au moyen des deux (2)
vis 6-32 fournies.
Se reporter aux tableaux du National Electrical Code, articleSe reporter aux tableaux du National Electrical Code, article
Se reporter aux tableaux du National Electrical Code, articleSe reporter aux tableaux du National Electrical Code, article
Se reporter aux tableaux du National Electrical Code, article
400, pour connaître le type et le calibre des fils convenant à400, pour connaître le type et le calibre des fils convenant à
400, pour connaître le type et le calibre des fils convenant à400, pour connaître le type et le calibre des fils convenant à
400, pour connaître le type et le calibre des fils convenant à
l’application et à la charge en présence.l’application et à la charge en présence.
l’application et à la charge en présence.l’application et à la charge en présence.
l’application et à la charge en présence.
22
22
2
33
33
3
55
55
5
44
44
4
P
K
-
9
2
6
6
4
-
1
0
-
0
2
-
0
B
P
K
-
9
2
6
6
4
-
1
0
-
0
2
-
0
B