Installation Instructions for
Broderick Linear Chandelier
1.0
F3227-10
Chandelier
F3227/10
1
2
1A
3
4
5
Temporarily install the mounting plate to the junction box, mark the anchor hole locations, and remove the mounting plate.
Drill appropriate size holes at the marked locations and install the anchors.
Secure the mounting plate to the junction box and screw the anchor screws into the anchors.
Feed the fixture wires through the frame stems and screw them onto the socket assembly, then install the nipples onto the frame stems.
Feed the fixture wires through the center and outer frames, then place them onto the nipples making sure to insert the outer frame ends into the socket
assembly slots.
Determine the wanted height or look of the fixture with the provided swivel and stems and assemble them by screwing them together. All the parts may be
used alone or used in combination.
Feed the fixture wires through the stem assemblies and screw them onto the nipples.
Feed the fixture wires through the canopy, canopy plate, washers and nuts, then secure them to the swivels using the provided hex nuts as shown.
Connect the fixture to a suitable ground with accordance to local electrical codes.
Connect the white fixture wire (square and/or rigid) to the neutral power line wire with a wire nut.
Connect the black fixture wire (round and/or smooth) to the hot power line wire with a wire nut.
Neatly place all the wires into the junction box and/or canopy, place the canopy onto the mounting plate studs, and secure it in place by using the cap nuts.
Install the candle tubes by sliding them over the sockets.
Install the candle followers by placing them on top of the candle tubes.
Screw the lamps into the sockets. Refer to the label on the lamp socket for Max Wattage information.
Install the shades over the sockets and onto the shade bases.
Screw the finials to the bottom of the socket assembly.
6
7
8
9
CAUTION RISK OF FIRE-
This product must be installed in accordance with the
applicable installation code by a person familiar with the
construction and operation of the product and the hazards
involved.
Use minimum 90°c supply conductors.
GP I :ENERAL RODUCT NFORMATION
These fixtures are intended to be installed utilizing compliant junctionNEC
boxes.
This product is safety listed for damp locations.
Incandescent lamps may be dimmed with a standard incandescent dimmer.
LED LEDlamps may be dimmed with a dimmer. Consult lamp manufacturer for
additional information.
STEM ASSEMBLY
SHADE
CANDLE TUBE
CANDLE FOLLOWER
16
14
13
FRAME STEM
OUTER FRAME
NIPPLE
LAMP
SOCKET
SHADE BASE
FINIAL
SOCKET ASSEMBLY
15
17
CENTER FRAME
HEX NUT & WASHER
CANOPY
ANCHOR
ANCHOR SCREW
CANOPY PLATE
MOUNTING PLATE
SWIVEL
10
11
12
13
14
15
16
17
4
7
CAP
NUT