Tannoy AMS Series Guía del usuario

Tipo
Guía del usuario
Quick Start Guide
AMS Series
AMS 8DC
8" Dual Concentric Surface-Mount Loudspeaker for Installation Applications
AMS 6DC, AMS 6ICT, AMS 6ICT LS
6" Dual Concentric/ICT Surface-Mount Loudspeaker for Installation
& Life Safety Installation Applications
AMS 5DC, AMS 5ICT, AMS 5ICT LS
5" Dual Concentric/ICT Surface-Mount Loudspeaker for Installation
& Life Safety Installation Applications
LEGAL DISCLAIMER
Important Safety
Instructions
Terminals marked with
this symbol carry
electrical current of
sucient magnitude to constitute risk
of electric shock. Use only high-quality
professional speaker cables with ¼" TS
or twist-locking plugs pre-installed.
Allother installation or modication
should be performed only by
qualiedpersonnel.
This symbol, wherever it
appears, alerts you to the
presence of uninsulated
dangerous voltage inside the enclosure
- voltage that may be sucient to
constitute a risk ofshock.
This symbol, wherever it
appears, alerts you to
important operating and
maintenance instructions in the
accompanying literature. Please read
themanual.
Caution
To reduce the risk of
electric shock, do not
remove the top cover (or the rear
section). No user serviceable parts inside.
Refer servicing to qualiedpersonnel.
Caution
To reduce the risk of
re or electric shock, do
not expose this appliance to rain and
moisture. Theapparatus shall not
be exposed to dripping or splashing
liquids and no objects lled with
liquids, such as vases, shall be placed
on the apparatus.
Caution
These service instructions
are for use by qualied
service personnel only. Toreduce
the risk of electric shock do not
perform any servicing other than that
contained in the operation instructions.
Repairshave to be performed by
qualied servicepersonnel.
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus
near water.
6. Clean only with dry cloth.
7. Do not block any ventilation
openings. Install in accordance with the
manufacturer’s instructions.
8. Do not install near any heat
sources such as radiators, heat registers,
stoves, or other apparatus (including
ampliers) that produce heat.
9. Do not defeat the safety purpose
of the polarized or grounding-type
plug. A polarized plug has two blades
with one wider than the other.
A grounding-type plug has two blades
and a third grounding prong. The wide
blade or the third prong are provided
for your safety. Ifthe provided plug
does not t into your outlet, consult
an electrician for replacement of the
obsolete outlet.
10. Protect the power cord from being
walked on or pinched particularly
at plugs, convenience receptacles,
and the point where they exit from
the apparatus.
11. Use only attachments/accessories
specied by themanufacturer.
12. Use only with
the cart, stand,
tripod, bracket, or
table specied by
the manufacturer,
orsold with
the apparatus. When a cart is used,
use caution when moving the cart/
apparatus combination to avoid injury
from tip-over.
13. Unplug this apparatus during
lightning storms or when unused for
long periods of time.
14. Refer all servicing to qualied
service personnel. Servicing is required
when the apparatus has been damaged
in any way, such as power supply cord
or plug is damaged, liquid has been
spilled or objects have fallen into the
apparatus, the apparatus has been
exposed to rain or moisture, does not
operate normally, or has beendropped.
15. The apparatus shall be connected
to a MAINS socket outlet with a
protective earthing connection.
16. Where the MAINS plug or an
appliance coupler is used as the
disconnect device, the disconnect
device shall remain readily operable.
17. Correct disposal of
this product: This
symbol indicates that
this product must not
be disposed of with
household waste, according to the
WEEE Directive (2012/19/EU) and your
national law. This product should be
taken to a collection center licensed for
the recycling of waste electrical and
electronic equipment (EEE).
The mishandling of this type of waste
could have a possible negative impact
on the environment and human health
due to potentially hazardous
substances that are generally
associated with EEE. At the same time,
your cooperation in the correct disposal
of this product will contribute to the
ecient use of natural resources. For
more information about where you can
take your waste equipment for
recycling, please contact your local city
oce, or your household waste
collection service.
18. Do not install in a conned space,
such as a book case or similar unit.
19. Do not place naked ame
sources, such as lighted candles,
on the apparatus.
20. Please keep the environmental
aspects of battery disposal in mind.
Batteries must be disposed-of at a
battery collection point.
21. Use this apparatus in tropical
and/or moderate climates.
Music Tribe accepts no liability for
any loss which may be suered by
any person who relies either wholly
or in part upon any description,
photograph, or statement contained
herein. Technical specications,
appearances and other information
are subject to change without notice.
2 3Quick Start GuideAMS Series
All trademarks are the property
of their respective owners. Midas,
Klark Teknik, Lab Gruppen, Lake,
Tannoy, Turbosound, TC Electronic,
TC Helicon, Behringer, Bugera and
Coolaudio are trademarks or registered
trademarks of Music Tribe Global
Brands Ltd. © Music Tribe Global
Brands Ltd. 2018 All rights reserved.
For the applicable warranty terms and
conditions and additional information
regarding Music Tribe’s Limited
Warranty, please see complete details
online at musictribe.com/warranty.
Zhongshan Eurotec
Electronics Limited
No. 10 Wanmei Road, South China
Modern Chinese Medicine Park,
Nanlang Town, 528451, Zhongshan
City, Guangdong Province, China
Las terminales marcadas
con este símbolo
transportan corriente
eléctrica de magnitud suciente como
para constituir un riesgo de descarga
eléctrica. Utilicesolo cables de altavoz
profesionales y de alta calidad con
conectores TS de 6,3 mm o de bayoneta
prejados. Cualquier otra instalación o
modicación debe ser realizada
únicamente por un técnicocualicado.
Este símbolo, siempre que
aparece, leadvierte de la
presencia de voltaje
peligroso sin aislar dentro de la caja;
estevoltaje puede ser suciente para
constituir un riesgo dedescarga.
Este símbolo, siempre que
aparece, leadvierte sobre
instrucciones operativas y
de mantenimiento que aparecen en la
documentación adjunta. Por favor,
leaelmanual.
Atención
Para reducir el riesgo de
descarga eléctrica, no
quite la tapa (olaparte posterior).
Nohay piezas en el interior del equipo
que puedan ser reparadas por el
usuario. Sies necesario, póngase en
contacto con personal cualicado.
Atención
Para reducir el riesgo
de incendio o descarga
eléctrica, no exponga este aparato a la
lluvia, humedad o alguna otra fuente
que pueda salpicar o derramar algún
líquido sobre el aparato. Nocoloque
ningún tipo de recipiente para líquidos
sobre elaparato.
Atención
Las instrucciones
de servicio deben
llevarlas a cabo exclusivamente
personal cualicado. Paraevitar el
riesgo de una descarga eléctrica,
no realice reparaciones que no se
encuentren descritas en el manual de
operaciones. Lasreparaciones deben
ser realizadas exclusivamente por
personalcualicado.
1. Lea las instrucciones.
2. Conserve estas instrucciones.
3. Preste atención a todas
las advertencias.
4. Siga todas las instrucciones.
5. No use este aparato cerca
del agua.
6. Limpie este aparato con un
paño seco.
7. No bloquee las aberturas
de ventilación. Instale el equipo
de acuerdo con las instrucciones
del fabricante.
8. No instale este equipo cerca de
fuentes de calor tales como radiadores,
acumuladores de calor, estufas u otros
aparatos (incluyendo amplicadores)
que puedan producir calor.
9. No elimine o deshabilite nunca
la conexión a tierra del aparato o del
cable de alimentación de corriente.
Unenchufe polarizado tiene dos polos,
uno de los cuales tiene un contacto
más ancho que el otro. Una clavija
con puesta a tierra dispone de tres
contactos: dos polos y la puesta a
tierra. El contacto ancho y el tercer
contacto, respectivamente, son los que
garantizan una mayor seguridad. Si el
enchufe suministrado con el equipo
no concuerda con la toma de corriente,
consulte con un electricista para
cambiar la toma de corriente obsoleta.
10. Coloque el cable de suministro de
energía de manera que no pueda ser
pisado y que esté protegido de objetos
alados. Asegúrese de que el cable de
suministro de energía esté protegido,
especialmente en la zona de la clavija y
en el punto donde sale del aparato.
11. Use únicamente los dispositivos
o accesorios especicados por
el fabricante.
12. Use
únicamente la
carretilla,
plataforma,
trípode, soporte o
mesa especicados
por el fabricante o suministrados junto
con el equipo. Altransportar el equipo,
tenga cuidado para evitar daños y
caídas al tropezar con algún obstáculo.
13. Desenchufe el equipo durante
tormentas o si no va a utilizarlo durante
un periodo largo.
14. Confíe las reparaciones
únicamente a servicios técnicos
cualicados. La unidad requiere
mantenimiento siempre que haya
sufrido algún daño, si el cable de
suministro de energía o el enchufe
presentaran daños, sehubiera
derramado un líquido o hubieran caído
objetos dentro del equipo, si el aparato
hubiera estado expuesto a la humedad
o la lluvia, si ha dejado de funcionar de
manera normal o si ha sufrido algún
golpe o caída.
15. Al conectar la unidad a la toma de
corriente eléctrica asegúrese de que
la conexión disponga de una unión
atierra.
LIMITED WARRANTY
Instrucciones de
seguridad
LEGAL DISCLAIMER
Important Safety
Instructions
Terminals marked with
this symbol carry
electrical current of
sucient magnitude to constitute risk
of electric shock. Use only high-quality
professional speaker cables with ¼" TS
or twist-locking plugs pre-installed.
Allother installation or modication
should be performed only by
qualiedpersonnel.
This symbol, wherever it
appears, alerts you to the
presence of uninsulated
dangerous voltage inside the enclosure
- voltage that may be sucient to
constitute a risk ofshock.
This symbol, wherever it
appears, alerts you to
important operating and
maintenance instructions in the
accompanying literature. Please read
themanual.
Caution
To reduce the risk of
electric shock, do not
remove the top cover (or the rear
section). No user serviceable parts inside.
Refer servicing to qualiedpersonnel.
Caution
To reduce the risk of
re or electric shock, do
not expose this appliance to rain and
moisture. Theapparatus shall not
be exposed to dripping or splashing
liquids and no objects lled with
liquids, such as vases, shall be placed
on the apparatus.
Caution
These service instructions
are for use by qualied
service personnel only. Toreduce
the risk of electric shock do not
perform any servicing other than that
contained in the operation instructions.
Repairshave to be performed by
qualied servicepersonnel.
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus
near water.
6. Clean only with dry cloth.
7. Do not block any ventilation
openings. Install in accordance with the
manufacturer’s instructions.
8. Do not install near any heat
sources such as radiators, heat registers,
stoves, or other apparatus (including
ampliers) that produce heat.
9. Do not defeat the safety purpose
of the polarized or grounding-type
plug. A polarized plug has two blades
with one wider than the other.
A grounding-type plug has two blades
and a third grounding prong. The wide
blade or the third prong are provided
for your safety. Ifthe provided plug
does not t into your outlet, consult
an electrician for replacement of the
obsolete outlet.
10. Protect the power cord from being
walked on or pinched particularly
at plugs, convenience receptacles,
and the point where they exit from
the apparatus.
11. Use only attachments/accessories
specied by themanufacturer.
12. Use only with
the cart, stand,
tripod, bracket, or
table specied by
the manufacturer,
orsold with
the apparatus. When a cart is used,
use caution when moving the cart/
apparatus combination to avoid injury
from tip-over.
13. Unplug this apparatus during
lightning storms or when unused for
long periods of time.
14. Refer all servicing to qualied
service personnel. Servicing is required
when the apparatus has been damaged
in any way, such as power supply cord
or plug is damaged, liquid has been
spilled or objects have fallen into the
apparatus, the apparatus has been
exposed to rain or moisture, does not
operate normally, or has beendropped.
15. The apparatus shall be connected
to a MAINS socket outlet with a
protective earthing connection.
16. Where the MAINS plug or an
appliance coupler is used as the
disconnect device, the disconnect
device shall remain readily operable.
17. Correct disposal of
this product: This
symbol indicates that
this product must not
be disposed of with
household waste, according to the
WEEE Directive (2012/19/EU) and your
national law. This product should be
taken to a collection center licensed for
the recycling of waste electrical and
electronic equipment (EEE).
The mishandling of this type of waste
could have a possible negative impact
on the environment and human health
due to potentially hazardous
substances that are generally
associated with EEE. At the same time,
your cooperation in the correct disposal
of this product will contribute to the
ecient use of natural resources. For
more information about where you can
take your waste equipment for
recycling, please contact your local city
oce, or your household waste
collection service.
18. Do not install in a conned space,
such as a book case or similar unit.
19. Do not place naked ame
sources, such as lighted candles,
on the apparatus.
20. Please keep the environmental
aspects of battery disposal in mind.
Batteries must be disposed-of at a
battery collection point.
21. Use this apparatus in tropical
and/or moderate climates.
Music Tribe accepts no liability for
any loss which may be suered by
any person who relies either wholly
or in part upon any description,
photograph, or statement contained
herein. Technical specications,
appearances and other information
are subject to change without notice.
2 3Quick Start GuideAMS Series
All trademarks are the property
of their respective owners. Midas,
Klark Teknik, Lab Gruppen, Lake,
Tannoy, Turbosound, TC Electronic,
TC Helicon, Behringer, Bugera and
Coolaudio are trademarks or registered
trademarks of Music Tribe Global
Brands Ltd. © Music Tribe Global
Brands Ltd. 2018 All rights reserved.
For the applicable warranty terms and
conditions and additional information
regarding Music Tribe’s Limited
Warranty, please see complete details
online at musictribe.com/warranty.
Zhongshan Eurotec
Electronics Limited
No. 10 Wanmei Road, South China
Modern Chinese Medicine Park,
Nanlang Town, 528451, Zhongshan
City, Guangdong Province, China
Las terminales marcadas
con este símbolo
transportan corriente
eléctrica de magnitud suciente como
para constituir un riesgo de descarga
eléctrica. Utilicesolo cables de altavoz
profesionales y de alta calidad con
conectores TS de 6,3 mm o de bayoneta
prejados. Cualquier otra instalación o
modicación debe ser realizada
únicamente por un técnicocualicado.
Este símbolo, siempre que
aparece, leadvierte de la
presencia de voltaje
peligroso sin aislar dentro de la caja;
estevoltaje puede ser suciente para
constituir un riesgo dedescarga.
Este símbolo, siempre que
aparece, leadvierte sobre
instrucciones operativas y
de mantenimiento que aparecen en la
documentación adjunta. Por favor,
leaelmanual.
Atención
Para reducir el riesgo de
descarga eléctrica, no
quite la tapa (olaparte posterior).
Nohay piezas en el interior del equipo
que puedan ser reparadas por el
usuario. Sies necesario, póngase en
contacto con personal cualicado.
Atención
Para reducir el riesgo
de incendio o descarga
eléctrica, no exponga este aparato a la
lluvia, humedad o alguna otra fuente
que pueda salpicar o derramar algún
líquido sobre el aparato. Nocoloque
ningún tipo de recipiente para líquidos
sobre elaparato.
Atención
Las instrucciones
de servicio deben
llevarlas a cabo exclusivamente
personal cualicado. Paraevitar el
riesgo de una descarga eléctrica,
no realice reparaciones que no se
encuentren descritas en el manual de
operaciones. Lasreparaciones deben
ser realizadas exclusivamente por
personalcualicado.
1. Lea las instrucciones.
2. Conserve estas instrucciones.
3. Preste atención a todas
las advertencias.
4. Siga todas las instrucciones.
5. No use este aparato cerca
del agua.
6. Limpie este aparato con un
paño seco.
7. No bloquee las aberturas
de ventilación. Instale el equipo
de acuerdo con las instrucciones
del fabricante.
8. No instale este equipo cerca de
fuentes de calor tales como radiadores,
acumuladores de calor, estufas u otros
aparatos (incluyendo amplicadores)
que puedan producir calor.
9. No elimine o deshabilite nunca
la conexión a tierra del aparato o del
cable de alimentación de corriente.
Unenchufe polarizado tiene dos polos,
uno de los cuales tiene un contacto
más ancho que el otro. Una clavija
con puesta a tierra dispone de tres
contactos: dos polos y la puesta a
tierra. El contacto ancho y el tercer
contacto, respectivamente, son los que
garantizan una mayor seguridad. Si el
enchufe suministrado con el equipo
no concuerda con la toma de corriente,
consulte con un electricista para
cambiar la toma de corriente obsoleta.
10. Coloque el cable de suministro de
energía de manera que no pueda ser
pisado y que esté protegido de objetos
alados. Asegúrese de que el cable de
suministro de energía esté protegido,
especialmente en la zona de la clavija y
en el punto donde sale del aparato.
11. Use únicamente los dispositivos
o accesorios especicados por
el fabricante.
12. Use
únicamente la
carretilla,
plataforma,
trípode, soporte o
mesa especicados
por el fabricante o suministrados junto
con el equipo. Altransportar el equipo,
tenga cuidado para evitar daños y
caídas al tropezar con algún obstáculo.
13. Desenchufe el equipo durante
tormentas o si no va a utilizarlo durante
un periodo largo.
14. Confíe las reparaciones
únicamente a servicios técnicos
cualicados. La unidad requiere
mantenimiento siempre que haya
sufrido algún daño, si el cable de
suministro de energía o el enchufe
presentaran daños, sehubiera
derramado un líquido o hubieran caído
objetos dentro del equipo, si el aparato
hubiera estado expuesto a la humedad
o la lluvia, si ha dejado de funcionar de
manera normal o si ha sufrido algún
golpe o caída.
15. Al conectar la unidad a la toma de
corriente eléctrica asegúrese de que
la conexión disponga de una unión
atierra.
LIMITED WARRANTY
Instrucciones de
seguridad
GARANTIA LIMITADA
LEGAL RENUNCIANTE
impacto negativo no ambiente e na
saúde humana devido a substâncias
potencialmente perigosas que estão
geralmente associadas aos EEE. Ao
mesmo tempo, a sua colaboração para a
eliminação correcta deste produto irá
contribuir para a utilização eciente dos
recursos naturais. Paramais informação
acerca dos locais onde poderá deixar o
seu equipamento usado para reciclagem,
é favor contactar os serviços municipais
locais, a entidade de geso de resíduos
ou os serviços de recolha de
resíduosdomésticos.
18. Não instale em lugares
connados, tais como estantes ou
unidades similares.
19. Não coloque fontes de
chama, tais como velas acesas,
sobre o aparelho.
20. Favor, obedecer os aspectos
ambientais de descarte de bateria.
Baterias devem ser descartadas em um
ponto de coletas de baterias.
21. Use este aparelho em climas
tropicais e/ou moderados.
O Music Tribe não se responsabiliza
por perda alguma que possa ser
sofrida por qualquer pessoa que
dependa, seja de maneira completa
ou parcial, de qualquer descrição,
fotograa, ou declaração aqui
contidas. Dados técnicos, aparências
e outras informações estão sujeitas
a modicações sem aviso prévio.
Todas as marcas são propriedade de seus
respectivos donos. Midas, Klark Teknik,
Lab Gruppen, Lake, Tannoy, Turbosound,
TC Electronic, TC Helicon, Behringer,
Bugera e Coolaudio são marcas ou
marcas registradas do Music Tribe Global
Brands Ltd. © Music Tribe Global Brands
Ltd. 2018 Todos direitos reservados.
Para obter os termos de garantia
aplicáveis e condições e informações
adicionais a respeito da garantia
limitada do Music Tribe, favor vericar
detalhes na íntegra através do website
musictribe.com/warranty.
8 9Quick Start GuideAMS Series
1. Introduction
Thank you for purchasing this new AMS Series product. Designed for both speech and music program material, the Tannoy AMS range
provides exceptional sonic quality and long-term reliability in all surface mount applications. The AMS range oers ve models: three
featuring a new generation of Dual Concentric drivers and two with an improved version of Tannoy’s ICT technology. All new drivers have
16 ohm nominal impedance for optimized use with Lab.gruppen ampliers. Other features include IP65 rating for outdoor use, high-
temperature molded cabinets and custom color options. All AMS loudspeakers include a built-in line transformer.
Because all AMS models are true point-source loudspeakers, they may be mounted horizontally or vertically without aecting
performance. All models include a standard mounting yoke; a multi-angle VariBall accessory bracket is available as an option.
2. Safety Notices
Installation Safety Notice
1. The user is responsible for xing the hardware to the surface to ensure safe operation. The xings must support the weight of the
product. Please consult the manuals specication page for the appropriate weights. Please consult the relevant construction codes
in your region for further information on suitable hardware xing methods.
2. Some regional construction codes require the use of a secondary method of securing loudspeakers to surfaces to provide security of a
back-up support. A secondary support line should be attached from the safety loop on the rear of the product to a source point on the
wall. Please consult the relevant construction codes in your region.
3. Tannoy will not be held accountable for any damage caused by incorrect installation.
Electrical Safety Notice: To comply with the standard UL1480, metal-clad exible conduit (BX) is required for connection to the
terminal block for proper earth grounding.
Safety Note: In order to comply with the relevant re safety regulations (i.e. BS 5839:1998), it is required that in the event of
re, that failure of the circuit to which the loudspeaker is connected does not occur before evacuation of the building is complete.
Suitable measures include:
• Use of terminal blocks (for connection to primary) with a melting point of not less than 650°C, for example constructed from ceramic materials;
• Use of terminal blocks of a lower melting point but protected with thermal insulation;
• Use of terminal blocks such that, on melting, an open-circuit or a short-circuit does not occur.
3. Unpacking
Every Tannoy product is carefully inspected before shipment. After unpacking, please inspect your product to ensure no damage has
occurred in transit. In the unlikely event of damage, please notify your dealer and retain all shipping materials as your dealer may require
return shipment.
4. Installation
Installation using included yoke bracket
1. Fix the yoke bracket to an appropriate structural surface using a suitable xing method.
2. Remove the yoke trims from the product to access the bracket xing points.
3. Set the transformer tap as detailed in Chapter 5.
4. For indoor installation (proceed to step 5 for outdoor installation): Connect the euro-style plug to the wires, observing correct
polarity. Use pins 1(+) and 2 (–) for connection of the loudspeaker. Use pins 3 (–) and 4 (+) for connection of additional loudspeakers in a
distributed line. NOTE: Tighten pins 3 and 4 even if not used to prevent vibration of the screws.
5. For outdoor installation: Feed the loudspeaker wire(s) through the opening in the neck of the cable entry cover included with the
product.
Connect the euro-style plug to the wires, observing correct polarity. Use pins 1(+) and 2 (
) for connection of the loudspeaker. Use
pins 3 (
) and 4 (+) for connection of additional loudspeakers in a distributed line. NOTE: Tighten pins 3 and 4 even if not used to
prevent vibration of the screws.
6. Place the loudspeaker inside the yoke bracket. Position buers between bracket and loudspeaker as shown. Attach with supplied xings
using a 5 mm Allen key. Use the longer hex screws supplied when mounting the yoke bracket.
7. Connect the euro plug to the loudspeaker. For outdoor installation, attach the cable entry cover using a 3 mm Allen key and the included
screws. Orient the cover plate so that the neck opening is facing downward to minimise entry of moisture or particulates.
8. Connect a secondary support line to the safety tab at the rear of the cabinet.
Optional multi-angle VariBall bracket
The optional multi-angle accessory bracket utilises a ball-in-socket design to enable free orientation of the loudspeaker at any angle on
either the horizontal or vertical axis. If desired, the loudspeaker orientation can be easily changed within minutes. Download the AMS
VariBall accessory bracket documentation for more details.
AMS 5 Multi-Angle Bracket AMS 6 & 8 Multi-Angle Bracket
10 11Quick Start GuideAMS Series
3. Unpacking
Every Tannoy product is carefully inspected before shipment. After unpacking, please inspect your product to ensure no damage has
occurred in transit. In the unlikely event of damage, please notify your dealer and retain all shipping materials as your dealer may require
return shipment.
4. Installation
Installation using included yoke bracket
1. Fix the yoke bracket to an appropriate structural surface using a suitable xing method.
2. Remove the yoke trims from the product to access the bracket xing points.
3. Set the transformer tap as detailed in Chapter 5.
4. For indoor installation (proceed to step 5 for outdoor installation): Connect the euro-style plug to the wires, observing correct
polarity. Use pins 1(+) and 2 (–) for connection of the loudspeaker. Use pins 3 (–) and 4 (+) for connection of additional loudspeakers in a
distributed line. NOTE: Tighten pins 3 and 4 even if not used to prevent vibration of the screws.
5. For outdoor installation: Feed the loudspeaker wire(s) through the opening in the neck of the cable entry cover included with the
product.
Connect the euro-style plug to the wires, observing correct polarity. Use pins 1(+) and 2 (
) for connection of the loudspeaker. Use
pins 3 (
) and 4 (+) for connection of additional loudspeakers in a distributed line. NOTE: Tighten pins 3 and 4 even if not used to
prevent vibration of the screws.
6. Place the loudspeaker inside the yoke bracket. Position buers between bracket and loudspeaker as shown. Attach with supplied xings
using a 5 mm Allen key. Use the longer hex screws supplied when mounting the yoke bracket.
7. Connect the euro plug to the loudspeaker. For outdoor installation, attach the cable entry cover using a 3 mm Allen key and the included
screws. Orient the cover plate so that the neck opening is facing downward to minimise entry of moisture or particulates.
8. Connect a secondary support line to the safety tab at the rear of the cabinet.
Optional multi-angle VariBall bracket
The optional multi-angle accessory bracket utilises a ball-in-socket design to enable free orientation of the loudspeaker at any angle on
either the horizontal or vertical axis. If desired, the loudspeaker orientation can be easily changed within minutes. Download the AMS
VariBall accessory bracket documentation for more details.
AMS 5 Multi-Angle Bracket AMS 6 & 8 Multi-Angle Bracket
10 11Quick Start GuideAMS Series
5. Setting transformer taps
1. The rotary transformer tapping switch is located directly above the wiring connector.
CAUTION: THE LOUDSPEAKER IS SUPPLIED WITH THE TAP SWITCH IN LOW IMPEDANCE MODE. NEVER CONNECT THE
LOUDSPEAKER TO A 70/100 V AMPLIFIER OUTPUT WHILE SWITCHED TO LOW IMPEDANCE MODE.
2. Set the rotary switch to the appropriate position for low impedance operation or for use in 70/100 V distributed systems.
Models with 5-inch drivers are tted with 30 W transformers. In distributed line applications, the transformer can be tapped at 30
W, 15 W and 7.5 W, with an additional 3.75 W tap for 70 V line systems.
Models with 6-inch and 8-inch drivers are tted with 60W transformers. In distributed line applications, the transformer can be
tapped at 60 W, 30 W and 15 W, with an additional 7.5 W tap for 70 V line systems.
6. Product Dimensions
AMS 8DC
AMS 6DC
259.7
[10.22"]
306.3
[12.06"]
407.5
[16.04"]
35.0
[1.38"]
90.0
[3.54"]
90.0
[3.54"]
Ø22.0
[Ø0.87"]
Ø11.0
[Ø0.43"]
6.0
[0.24"]
CABLE ENTRY COVER FOR EXTERNAL USE.
THIS CAN BE ROTATED FOR NORTH, SOUTH,
EAST OR WEST ENTRY.
54.0
[2.13"]
409.8
[16.13"]
260.0
[10.24"]
223.7
[8.81"]
268.8
[10.58"]
360.9
[14.21"]
54.0
[2.13"]
Ø22.0
[Ø0.87"]
Ø11.0
[Ø0.43"]
90.0
[3.54"]
90.0
[3.54"]
35.0
[1.38"]
364.8
[14.36"]
CABLE ENTRY COVER FOR EXTERNAL USE.
THIS CAN BE ROTATED FOR NORTH, SOUTH,
EAST OR WEST ENTRY.
6.0
[0.24"]
230.0
[9.05"]
12 13Quick Start GuideAMS Series
5. Setting transformer taps
1. The rotary transformer tapping switch is located directly above the wiring connector.
CAUTION: THE LOUDSPEAKER IS SUPPLIED WITH THE TAP SWITCH IN LOW IMPEDANCE MODE. NEVER CONNECT THE
LOUDSPEAKER TO A 70/100 V AMPLIFIER OUTPUT WHILE SWITCHED TO LOW IMPEDANCE MODE.
2. Set the rotary switch to the appropriate position for low impedance operation or for use in 70/100 V distributed systems.
Models with 5-inch drivers are tted with 30 W transformers. In distributed line applications, the transformer can be tapped at 30
W, 15 W and 7.5 W, with an additional 3.75 W tap for 70 V line systems.
Models with 6-inch and 8-inch drivers are tted with 60W transformers. In distributed line applications, the transformer can be
tapped at 60 W, 30 W and 15 W, with an additional 7.5 W tap for 70 V line systems.
6. Product Dimensions
AMS 8DC
AMS 6DC
259.7
[10.22"]
306.3
[12.06"]
407.5
[16.04"]
35.0
[1.38"]
90.0
[3.54"]
90.0
[3.54"]
Ø22.0
[Ø0.87"]
Ø11.0
[Ø0.43"]
6.0
[0.24"]
CABLE ENTRY COVER FOR EXTERNAL USE.
THIS CAN BE ROTATED FOR NORTH, SOUTH,
EAST OR WEST ENTRY.
54.0
[2.13"]
409.8
[16.13"]
260.0
[10.24"]
223.7
[8.81"]
268.8
[10.58"]
360.9
[14.21"]
54.0
[2.13"]
Ø22.0
[Ø0.87"]
Ø11.0
[Ø0.43"]
90.0
[3.54"]
90.0
[3.54"]
35.0
[1.38"]
364.8
[14.36"]
CABLE ENTRY COVER FOR EXTERNAL USE.
THIS CAN BE ROTATED FOR NORTH, SOUTH,
EAST OR WEST ENTRY.
6.0
[0.24"]
230.0
[9.05"]
12 13Quick Start GuideAMS Series
AMS 6ICT
AMS 6ICT LS
223.7
[8.81"]
268.8
[10.58"]
360.9
[14.21"]
54.0
[2.13"]
Ø22.0
[Ø0.87"]
Ø11.0
[Ø0.43"]
90.0
[3.54"]
90.0
[3.54"]
35.0
[1.38"]
364.8
[14.36"]
CABLE ENTRY COVER FOR EXTERNAL USE.
THIS CAN BE ROTATED FOR NORTH, SOUTH,
EAST OR WEST ENTRY.
6.0
[0.24"]
230.0
[9.05"]
223.7
[8.81"]
268.8
[10.58"]
360.9
[14.21"]
54.0
[2.13"]
Ø22.0
[Ø0.87"]
Ø11.0
[Ø0.43"]
90.0
[3.54"]
90.0
[3.54"]
35.0
[1.38"]
364.8
[14.36"]
CABLE ENTRY COVER FOR EXTERNAL USE.
THIS CAN BE ROTATED FOR NORTH, SOUTH,
EAST OR WEST ENTRY.
6.0
[0.24"]
230.0
[9.05"]
AMS 5DC
AMS 5ICT
159.5
[6.28"]
240.0
[9.45"]
155.0
[6.10"]
54.0
[2.13"]
203.9
[8.03"]
90.0
[3.54"]
90.0
[3.54"]
Ø11.0
[Ø0.43"]
Ø22.0
[Ø0.87"]
6.0
[0.24"]
248.0
[9.77"]
CABLE ENTRY COVER FOR EXTERNAL USE.
THIS CAN BE ROTATED FOR NORTH, SOUTH,
EAST OR WEST ENTRY.
35.0
[1.38"]
159.5
[6.28"]
240.0
[9.45"]
155.0
[6.10"]
54.0
[2.13"]
203.9
[8.03"]
90.0
[3.54"]
90.0
[3.54"]
Ø11.0
[Ø0.43"]
Ø22.0
[Ø0.87"]
6.0
[0.24"]
248.0
[9.77"]
CABLE ENTRY COVER FOR EXTERNAL USE.
THIS CAN BE ROTATED FOR NORTH, SOUTH,
EAST OR WEST ENTRY.
35.0
[1.38"]
14 15Quick Start GuideAMS Series
AMS 6ICT
AMS 6ICT LS
223.7
[8.81"]
268.8
[10.58"]
360.9
[14.21"]
54.0
[2.13"]
Ø22.0
[Ø0.87"]
Ø11.0
[Ø0.43"]
90.0
[3.54"]
90.0
[3.54"]
35.0
[1.38"]
364.8
[14.36"]
CABLE ENTRY COVER FOR EXTERNAL USE.
THIS CAN BE ROTATED FOR NORTH, SOUTH,
EAST OR WEST ENTRY.
6.0
[0.24"]
230.0
[9.05"]
223.7
[8.81"]
268.8
[10.58"]
360.9
[14.21"]
54.0
[2.13"]
Ø22.0
[Ø0.87"]
Ø11.0
[Ø0.43"]
90.0
[3.54"]
90.0
[3.54"]
35.0
[1.38"]
364.8
[14.36"]
CABLE ENTRY COVER FOR EXTERNAL USE.
THIS CAN BE ROTATED FOR NORTH, SOUTH,
EAST OR WEST ENTRY.
6.0
[0.24"]
230.0
[9.05"]
AMS 5DC
AMS 5ICT
159.5
[6.28"]
240.0
[9.45"]
155.0
[6.10"]
54.0
[2.13"]
203.9
[8.03"]
90.0
[3.54"]
90.0
[3.54"]
Ø11.0
[Ø0.43"]
Ø22.0
[Ø0.87"]
6.0
[0.24"]
248.0
[9.77"]
CABLE ENTRY COVER FOR EXTERNAL USE.
THIS CAN BE ROTATED FOR NORTH, SOUTH,
EAST OR WEST ENTRY.
35.0
[1.38"]
159.5
[6.28"]
240.0
[9.45"]
155.0
[6.10"]
54.0
[2.13"]
203.9
[8.03"]
90.0
[3.54"]
90.0
[3.54"]
Ø11.0
[Ø0.43"]
Ø22.0
[Ø0.87"]
6.0
[0.24"]
248.0
[9.77"]
CABLE ENTRY COVER FOR EXTERNAL USE.
THIS CAN BE ROTATED FOR NORTH, SOUTH,
EAST OR WEST ENTRY.
35.0
[1.38"]
14 15Quick Start GuideAMS Series
AMS 5ICT LS
159.5
[6.28"]
240.0
[9.45"]
155.0
[6.10"]
54.0
[2.13"]
203.9
[8.03"]
90.0
[3.54"]
90.0
[3.54"]
Ø11.0
[Ø0.43"]
Ø22.0
[Ø0.87"]
6.0
[0.24"]
248.0
[9.77"]
CABLE ENTRY COVER FOR EXTERNAL USE.
THIS CAN BE ROTATED FOR NORTH, SOUTH,
EAST OR WEST ENTRY.
35.0
[1.38"]
Specications
System AMS 8DC
Performance
Frequency response (-3 dB) (1) 65 Hz - 30 kHz
Frequency range (-10 dB) (1) 53 Hz - 40 kHz
System sensitivity (1 W @ 1m) (2) 92 dB (1 W = 4 V for 16 ohms)
Nominal Coverage Angle 90 degrees conical
Power Handling (3)
Average 90 W
Programme 180 W
Peak 360 W
Recommended Amplier Power 180 W @ 16 ohms
Nominal Impedance (Lo, Z) 16 ohms
Rated Maximum SPL
Average 111 dB
Peak 117 dB
Transformer Taps (via front rotary switch)
70 V 60 W / 30 W / 15 W / 7.5 W / OFF & Low impedance operation
100 V 60 W / 30 W / 15 W / OFF & Low impedance operation
Transducers
Dual Concentric point source driver 1x 200 mm (8.00") Dual Concentric driver, using Omnimagnet
technology
Low Frequency 44 mm (1.75" ) voice coil, treated multi bre paper pulp cone
High Frequency 25 mm (1.00") PEI dome
Physical
Enclosure ABS
Grille Steel, plated and painted
Connectors Removable locking connector with screw terminals
Transformer setting Rotary switch
Dimensions (H x W x D) 409.8 x 260.0 x 306.3 mm (16.13 x 10.24 x 12.06")
Net Weight (ea) 7.8 kg (17.20 lbs)
Shipped weight 8.8 kg (19.40 lbs)
Included Accessories Yoke bracket
Packed Quantity 2
16 17Quick Start GuideAMS Series
AMS 5ICT LS
159.5
[6.28"]
240.0
[9.45"]
155.0
[6.10"]
54.0
[2.13"]
203.9
[8.03"]
90.0
[3.54"]
90.0
[3.54"]
Ø11.0
[Ø0.43"]
Ø22.0
[Ø0.87"]
6.0
[0.24"]
248.0
[9.77"]
CABLE ENTRY COVER FOR EXTERNAL USE.
THIS CAN BE ROTATED FOR NORTH, SOUTH,
EAST OR WEST ENTRY.
35.0
[1.38"]
Specications
System AMS 8DC
Performance
Frequency response (-3 dB) (1) 65 Hz - 30 kHz
Frequency range (-10 dB) (1) 53 Hz - 40 kHz
System sensitivity (1 W @ 1m) (2) 92 dB (1 W = 4 V for 16 ohms)
Nominal Coverage Angle 90 degrees conical
Power Handling (3)
Average 90 W
Programme 180 W
Peak 360 W
Recommended Amplier Power 180 W @ 16 ohms
Nominal Impedance (Lo, Z) 16 ohms
Rated Maximum SPL
Average 111 dB
Peak 117 dB
Transformer Taps (via front rotary switch)
70 V 60 W / 30 W / 15 W / 7.5 W / OFF & Low impedance operation
100 V 60 W / 30 W / 15 W / OFF & Low impedance operation
Transducers
Dual Concentric point source driver 1x 200 mm (8.00") Dual Concentric driver, using Omnimagnet
technology
Low Frequency 44 mm (1.75" ) voice coil, treated multi bre paper pulp cone
High Frequency 25 mm (1.00") PEI dome
Physical
Enclosure ABS
Grille Steel, plated and painted
Connectors Removable locking connector with screw terminals
Transformer setting Rotary switch
Dimensions (H x W x D) 409.8 x 260.0 x 306.3 mm (16.13 x 10.24 x 12.06")
Net Weight (ea) 7.8 kg (17.20 lbs)
Shipped weight 8.8 kg (19.40 lbs)
Included Accessories Yoke bracket
Packed Quantity 2
16 17Quick Start GuideAMS Series
System AMS 6DC AMS 6ICT AMS 6ICT LS
Performance
Frequency response
(-3 dB) (1) 75 Hz - 30 kHz 75 Hz - 22 kHz 75 Hz - 30 kHz
Frequency range
(-10 dB) (1) 55 Hz - 40 kHz 55 Hz - 30 kHz
System sensitivity
(1 W @ 1m) (2) 89 dB (1 W = 4 V for 16 ohms) 90 dB (1 W = 4 V for 16 ohms)
Nominal Coverage Angle 90 degrees conical
Power Handling (3)
Average 80 W 60 W
Programme 160 W 120 W
Peak 320 W 240 W
Recommended Amplier
Power 160 W @ 16 ohms 120 W @ 16 ohms
Nominal Impedance (Lo, Z) 16 ohms
Rated Maximum SPL
Average 108 dB
Peak 114 dB
Transformer Taps (via front rotary switch)
70 V 60 W / 30 W / 15 W / 7.5 W / OFF & Low impedance operation
100 V 60 W / 30 W / 15 W / OFF & Low impedance operation
Transducers
Dual Concentric point
source driver
1x 165 mm (6.50") Dual
Concentric driver, using
Omnimagnet technology
Low Frequency
44 mm (1.75" ) voice coil,
treated multi bre paper
pulp cone
1 x 165 mm (6.50") treated multi bre paper pulp cone
High Frequency 25 mm (1.00") PEI dome ICT
Physical
Enclosure ABS
Grille Steel, plated and painted
Connectors Removable locking connector with screw terminals
Transformer setting Rotary switch
Dimensions (H x W x D) 364.8 x 230.0 x 268.8 mm (14.36 x 9.05 x 10.58")
Net Weight (ea) 6.25 kg (13.78 lbs) 5.25 kg (11.57 lbs) 5.4 kg (11.90 lbs)
Shipped weight 7.1 kg (15.6 lbs) 6.1 kg (13.4 lbs) 6.25 kg (13.77 lbs)
Included Accessories Yoke bracket
Packed Quantity 2
System AMS 5DC AMS 5ICT AMS 5ICT LS
Performance
Frequency response
(-3 dB) (1) 90 Hz - 30 kHz 90 Hz - 22 kHz
Frequency range
(-10 dB) (1) 80 Hz - 40 kHz 80 Hz - 30 kHz
System sensitivity
(1 W @ 1m) (2) 87 dB (1 W = 4 V for 16 Ohms) 88 dB (1 W = 4 V for 16 Ohms)
Nominal Coverage Angle 90 degrees conical
Power Handling (3)
Average 60 W 50 W
Programme 120 W 100 W
Peak 240 W 200 W
Recommended Amplier
Power 120 W @ 16 ohms 100 W @ 16 ohms
Nominal Impedance (Lo, Z) 16 ohms
Rated Maximum SPL
Average 105 dB
Peak 111 dB
Transformer Taps (via front rotary switch)
70 V 30 W / 15 W / 7.5 W / 3.75 W / OFF & Low impedance operation
100 V 30 W / 15 W / 7.5 W / OFF & Low impedance operation
Transducers
Dual Concentric point
source driver
1x 130 mm (5.0") Dual
Concentric driver, using
Omnimagnet technology
Low Frequency
35 mm (1.38" ) voice coil,
treated multi bre paper
pulp cone
1 x 130 mm (5.00") treated multi bre paper pulp cone
High Frequency 20 mm (0.79") PEI dome ICT
Physical
Enclosure ABS
Grille Steel, plated and painted
Connectors Removable locking connector with screw terminals
Transformer setting Rotary switch
Dimensions (H x W x D) 248.0 x 155.0 x 203.9 mm (9.77 x 6.10 x 8.03")
Net Weight (ea) 3.6 kg (7.9 lbs) 3.4 kg (7.5 lbs) 3.45 kg (7.60 lbs)
Shipped weight 4.15 kg (9.15 lbs) 3.95 kg (8.70 lbs) 4.0 kg (8.82 lbs)
Included Accessories Yoke bracket
Packed Quantity 2
18 19Quick Start GuideAMS Series
System AMS 6DC AMS 6ICT AMS 6ICT LS
Performance
Frequency response
(-3 dB) (1) 75 Hz - 30 kHz 75 Hz - 22 kHz 75 Hz - 30 kHz
Frequency range
(-10 dB) (1) 55 Hz - 40 kHz 55 Hz - 30 kHz
System sensitivity
(1 W @ 1m) (2) 89 dB (1 W = 4 V for 16 ohms) 90 dB (1 W = 4 V for 16 ohms)
Nominal Coverage Angle 90 degrees conical
Power Handling (3)
Average 80 W 60 W
Programme 160 W 120 W
Peak 320 W 240 W
Recommended Amplier
Power 160 W @ 16 ohms 120 W @ 16 ohms
Nominal Impedance (Lo, Z) 16 ohms
Rated Maximum SPL
Average 108 dB
Peak 114 dB
Transformer Taps (via front rotary switch)
70 V 60 W / 30 W / 15 W / 7.5 W / OFF & Low impedance operation
100 V 60 W / 30 W / 15 W / OFF & Low impedance operation
Transducers
Dual Concentric point
source driver
1x 165 mm (6.50") Dual
Concentric driver, using
Omnimagnet technology
Low Frequency
44 mm (1.75" ) voice coil,
treated multi bre paper
pulp cone
1 x 165 mm (6.50") treated multi bre paper pulp cone
High Frequency 25 mm (1.00") PEI dome ICT
Physical
Enclosure ABS
Grille Steel, plated and painted
Connectors Removable locking connector with screw terminals
Transformer setting Rotary switch
Dimensions (H x W x D) 364.8 x 230.0 x 268.8 mm (14.36 x 9.05 x 10.58")
Net Weight (ea) 6.25 kg (13.78 lbs) 5.25 kg (11.57 lbs) 5.4 kg (11.90 lbs)
Shipped weight 7.1 kg (15.6 lbs) 6.1 kg (13.4 lbs) 6.25 kg (13.77 lbs)
Included Accessories Yoke bracket
Packed Quantity 2
System AMS 5DC AMS 5ICT AMS 5ICT LS
Performance
Frequency response
(-3 dB) (1) 90 Hz - 30 kHz 90 Hz - 22 kHz
Frequency range
(-10 dB) (1) 80 Hz - 40 kHz 80 Hz - 30 kHz
System sensitivity
(1 W @ 1m) (2) 87 dB (1 W = 4 V for 16 Ohms) 88 dB (1 W = 4 V for 16 Ohms)
Nominal Coverage Angle 90 degrees conical
Power Handling (3)
Average 60 W 50 W
Programme 120 W 100 W
Peak 240 W 200 W
Recommended Amplier
Power 120 W @ 16 ohms 100 W @ 16 ohms
Nominal Impedance (Lo, Z) 16 ohms
Rated Maximum SPL
Average 105 dB
Peak 111 dB
Transformer Taps (via front rotary switch)
70 V 30 W / 15 W / 7.5 W / 3.75 W / OFF & Low impedance operation
100 V 30 W / 15 W / 7.5 W / OFF & Low impedance operation
Transducers
Dual Concentric point
source driver
1x 130 mm (5.0") Dual
Concentric driver, using
Omnimagnet technology
Low Frequency
35 mm (1.38" ) voice coil,
treated multi bre paper
pulp cone
1 x 130 mm (5.00") treated multi bre paper pulp cone
High Frequency 20 mm (0.79") PEI dome ICT
Physical
Enclosure ABS
Grille Steel, plated and painted
Connectors Removable locking connector with screw terminals
Transformer setting Rotary switch
Dimensions (H x W x D) 248.0 x 155.0 x 203.9 mm (9.77 x 6.10 x 8.03")
Net Weight (ea) 3.6 kg (7.9 lbs) 3.4 kg (7.5 lbs) 3.45 kg (7.60 lbs)
Shipped weight 4.15 kg (9.15 lbs) 3.95 kg (8.70 lbs) 4.0 kg (8.82 lbs)
Included Accessories Yoke bracket
Packed Quantity 2
18 19Quick Start GuideAMS Series
Other important information
1. Register online.
Pleaseregister your new Music Tribe
equipment right after you purchase it
by visiting tannoy.com. Registeringyour
purchase using our simple online
form helps us to process your repair
claims more quickly and eciently.
Also, read the terms and conditions of
our warranty, ifapplicable.
2. Malfunction. Should your
Music Tribe Authorized Reseller not be
located in your vicinity, you may contact
the Music Tribe Authorized Fulller for
your country listed under “Support” at
tannoy.com. Shouldyour country not be
listed, pleasecheck if your problem can be
dealt with by our “OnlineSupport” which
may also be found under “Support” at
tannoy.com. Alternatively, please submit
an online warranty claim at tannoy.com
BEFORE returning theproduct.
3. Power Connections.
Beforeplugging the unit into a power
socket, please make sure you are using the
correct mains voltage for your particular
model. Faulty fuses must be replaced
with fuses of the same type and rating
withoutexception.
Important information
21Quick Start Guide
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Tannoy AMS Series Guía del usuario

Tipo
Guía del usuario

en otros idiomas