WARNING
Loss of life. This product is not intended to
be used in a critical life support application.
Failure to adhere to this warning could result
in death or serious injury.
Table of Contents
Section 1 Introduction and Safety 1
Introduction ..................................... 1
Safety Rules .................................... 1
Safety Symbols and Meanings ........ 1
Exhaust and Location Hazards ....... 2
Electrical Hazards ........................... 3
Fire Hazards .................................... 3
Lifting or Suspending Generator ..... 3
Standards Index .............................. 4
Section 2 General Information and
Setup .............................................. 5
Know Your Generator ..................... 6
Emissions ........................................ 6
Connection Plugs ............................ 7
Hour Meter ...................................... 8
Remove Contents from Carton ....... 8
Assembly ......................................... 9
Battery Cable Connection (if equipped)
10
Add Engine Oil .............................. 10
Fuel ............................................... 11
Section 3 Operation .................... 12
Operation and Use Questions ....... 12
Before Starting Engine .................. 12
Prepare Generator for Use ............ 12
Grounding the Generator When Used
as a Portable ................................. 12
Know Generator Limits .................. 13
Transporting/Tipping of the Unit .... 14
Starting Pull Start Engines ............ 14
Starting Electric Start Engines ...... 14
Generator Shut Down ................... 15
Low Oil Pressure Shutdown System .
15
Section 4 Maintenance and
Troubleshooting ..........................16
Maintenance ..................................16
Maintenance Schedule ..................16
Preventive Maintenance ................16
Engine Maintenance ......................16
Battery Replacement (if applicable) 18
Inspect Muffler and Spark Arrester 18
Valve Clearance ............................19
Storage ..........................................19
Troubleshooting .............................20
(000393a)
WARNING
CANCER AND REPRODUCTIVE HARM
www.P65Warnings.ca.gov.
Owner’s Manual for Portable Generator 1
Section 1 Introduction and Safety
Introduction
Thank you for purchasing a Generac Power
Systems Inc. product. This unit has been
designed to provide high-performance, effi-
cient operation, and years of use when main-
tained properly.
If any section of the manual is not understood,
contact your nearest Independent Authorized
Service Dealer (IASD), or contact Generac
Customer Service at 1-888-GENERAC (1-
888-436-3722), or www.generac.com with any
questions or concerns.
The owner is responsible for proper mainte-
nance and safe use of the equipment. Before
operating, servicing or storing this generator:
Study all warnings in this manual and on
the product carefully.
Become familiar with this manual and the
unit before use.
Refer to the Assembly section of the man-
ual for instructions on final assembly proce-
dures. Follow the instructions completely.
Save these instructions for future reference.
ALWAYS supply this manual to any individual
that will use this machine.
The information in this manual is accurate
based on products produced at the time of
publication. The manufacturer reserves the
right to make technical updates, corrections,
and product revisions at any time without
notice.
Safety Rules
The manufacturer cannot anticipate every
possible circumstance that might involve a
hazard. The alerts in this manual, and on tags
and decals affixed to the unit, are not all inclu-
sive. If using a procedure, work method, or
operating technique that the manufacturer
does not specifically recommend, verify that it
is safe for others and does not render the
equipment unsafe.
Throughout this publication, and on tags and
decals affixed to the unit, DANGER, WARN-
ING, CAUTION, and NOTE blocks are used to
alert personnel to special instructions about a
particular operation that may be hazardous if
performed incorrectly or carelessly. Observe
them carefully. Alert definitions are as follows:
NOTE: Notes contain additional information
important to a procedure and will be found
within the regular text of this manual.
These safety alerts cannot eliminate the haz-
ards that they indicate. Common sense and
strict compliance with the special instructions
while performing the action or service are
essential to preventing accidents.
Safety Symbols and Meanings
If you start to feel sick, dizzy, or weak after
the generator has been running, move to
fresh air IMMEDIATELY. See a doctor, as
you could have carbon monoxide poison-
ing.
(000100a)
WARNING
Consult Manual. Read and understand manual
completely before using product. Failure to
completely understand manual and product
could result in death or serious injury.
(000001)
DANGER
Indicates a hazardous situation which, if not avoided,
will result in death or serious injury.
(000002)
WARNING
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury.
(000003)
CAUTION
Indicates a hazardous situation which, if not avoided,
could result in minor or moderate injury.
DANGER
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is
a poison you cannot see or smell.
NEVER use inside a home
or garage, EVEN IF doors
and windows are open.
Only use OUTSIDE and
far away from windows,
doors, and vents.
000657
(000103)
DANGER
Asphyxiation. Running engines produce carbon
monoxide, a colorless, odorless, poisonous gas.
Carbon monoxide, if not avoided,
will result in death or serious injury.
Asphyxiation. The exhaust system must be properly
as to render it unsafe or make it noncompliant with
local codes and/or standards. Failure to do so will
result in death or serious injury.
2 Owner’s Manual for Portable Generator
For safety reasons, it is recommended that
the maintenance of this equipment be per-
formed by an IASD. Inspect the generator
regularly, and contact the nearest IASD for
parts needing repair or replacement.
Exhaust and Location Hazards
If you start to feel sick, dizzy, or weak after
the generator has been running, move to
fresh air IMMEDIATELY. See a doctor, as
you could have carbon monoxide poison-
ing.
NEVER run a generator indoors or in a
partly enclosed area such as garages.
ONLY use outdoors and far away from win-
dows, doors, vents, crawl spaces and in an
area where adequate ventilation is avail-
able and will not accumulate deadly
exhaust gas.
Using a fan or opening a door will not pro-
vide sufficient ventilation.
Point muffler exhaust away from people
and occupied buildings.
(000104)
DANGER
Electrocution. Water contact with a power source,
if not avoided, will result in death or serious injury.
(000116)
DANGER
Electrocution. Turn utility and emergency
power supplies to OFF before connecting power
source and load lines. Failure to do so will result
in death or serious injury.
(000146)
WARNING
Equipment and property damage. Do not alter
construction of, installation, or block ventilation for
generator. Failure to do so could result in unsafe
operation or damage to the generator.
(000178a)
Asphyxiation. Always use a battery operated carbon
monoxide alarm indoors and installed according to
the manufacturer’s instructions. Failure to do so
could result in death or serious injury.
WARNING
(000250)
WARNING
Equipment and property damage. Do not operate unit on
uneven surfaces, or areas of excessive moisture, dirt, dust
or corrosive vapors. Doing so could result in death, serious
injury, property and equipment damage.
(000111)
WARNING
Moving Parts. Keep clothing, hair, and appendages
away from moving parts. Failure to do so could
result in death or serious injury.
(000108)
WARNING
Hot Surfaces. When operting machine, do not
touch hot surfaces. Keep machine away from
combustables during use. Hot surfaces
could result in severe burns or fire.
(000142a)
Personal injury. Do not insert any object through the
air cooling slots. Generator can start at any time and
could result in death, serious injury, and unit damage.
WARNING
WARNING
Risk of injury. Do not operate or service this machine
if not fully alert. Fatigue can impair the ability to service
this equipment and could result in death or serious
injury.
(000215)
WARNING
Injury and equipment damage. Do not use generator
as a step. Doing so could result in falling, damaged
parts, unsafe equipment operation, and could result
in death or serious injury.
(000216)
000406
(000103)
DANGER
Asphyxiation. Running engines produce carbon
monoxide, a colorless, odorless, poisonous gas.
Carbon monoxide, if not avoided,
will result in death or serious injury.
(000179b)
DANGER
Asphyxiation. The exhaust system must be properly
maintained. Do not alter or modify the exhaust system
as to render it unsafe or make it noncompliant with
local codes and/or standards. Failure to do so will
result in death or serious injury.
(000146)
WARNING
Equipment and property damage. Do not alter
construction of, installation, or block ventilation for
generator. Failure to do so could result in unsafe
operation or damage to the generator.
(000178a)
Asphyxiation. Always use a battery operated carbon
monoxide alarm indoors and installed according to
the manufacturer’s instructions. Failure to do so
could result in death or serious injury.
WARNING
Owner’s Manual for Portable Generator 3
Electrical Hazards
The National Electric Code (NEC) requires
the frame and external electrically conduc-
tive parts of the generator be properly con-
nected to an approved earth ground. Local
electrical codes may also require proper
grounding of the generator. Consult with a
local electrician for grounding requirements
in the area.
Fire Hazards
Do not operate the generator if connected
electrical devices overheat, if electrical out-
put is lost, if engine or generator sparks or if
flames or smoke are observed while unit is
running.
Keep a fire extinguisher near the generator
at all times.
Allow at least 5 feet of clearance on all
sides of the generator when operating to
prevent overheating and fire.
Lifting or Suspending Generator
(000144)
DANGER
Electrocution. Contact with bare wires,
terminals, and connections while generator
is running will result in death or serious injury.
(000104)
DANGER
Electrocution. Water contact with a power source,
if not avoided, will result in death or serious injury.
(000145)
DANGER
Electrocution. In the event of electrical accident,
immediately shut power OFF. Use non-conductive
implements to free victim from live conductor. Apply
first aid and get medical help. Failure to do so will
result in death or serious injury.
(000130)
WARNING
Accidental Start-up. Disconnect the negative battery
cable, then the positive battery cable when working
on unit. Failure to do so could result in death
or serious injury.
(000105)
DANGER
Explosion and Fire. Fuel and vapors are extremely
flammable and explosive. Add fuel in a well
ventilated area. Keep fire and spark away. Failure to
do so will result in death or serious injury.
(000166b)
DANGER
Explosion and Fire. Do not overfill fuel tank. Fill to
1/2 inch from top of tank to allow for fuel expansion.
Overfilling may cause fuel to spill onto engine causing
fire or explosion, which will result in death or
serious injury.
(000174)
DANGER
Risk of fire. Allow fuel spills to completely dry
before starting engine. Failure to do so will
result in death or serious injury.
(000142a)
Personal injury. Do not insert any object through the
air cooling slots. Generator can start at any time and
could result in death, serious injury, and unit damage.
WARNING
WARNING
Personal injury. Failure to properly connect
lifting cables, chains, or straps could result in
death, serious injury, or property damage.
(000346)
WARNING
Personal injury. Failure to use cables, chains, or
straps rated at 2000 lbs. (907 kg) working load or
greater to raise or suspend unit could result in
death, serious injury, or property damage.
(000347)
WARNING
Personal injury. Never operate generator while
suspended. Doing so could result in death,
serious injury, or property damage.
(000348)
WARNING
Personal Injury. Do not use lifting hook if there are
signs of damage or corrosion. Doing so could result
in death, serious injury, or property damage.
(000349)
WARNING
Personal Injury. Do not use lifting hook other than as
directed. Failure to do so could result in death, serious
injury, or property damage.
(000350)
WARNING
Personal Injury. Verify all fasteners are properly
tightened prior to lifting unit. Failure to do so could
result in death, serious injury, or property damage.
(000351)
4 Owner’s Manual for Portable Generator
Standards Index
1. National Fire Protection Association
(NFPA) 70: The NATIONAL ELECTRIC
CODE (NEC) available from www.nfpa.org
2. National Fire Protection Association
(NFPA) 5000: BUILDING CONSTRUC-
TION AND SAFETY CODE available from
www.nfpa.org
3. International Building Code available from
www.iccsafe.org
4. Agricultural Wiring Handbook available
from www.rerc.org, Rural Electricity
Resource Council P.O. Box 309 Wilming-
ton, OH 45177-0309
5. ASAE EP-364.2 Installation and Mainte-
nance of Farm Standby Electric Power
available from www.asabe.org, American
Society of Agricultural & Biological Engi-
neers 2950 Niles Road, St. Joseph, MI
49085
6. Safety and Performance of Portable Gen-
erators ANSI/PGMA G300 available from
pgmaonline.com
7. CSA C22.2 100-14 Electric motors and
generators for installation and use, in
accordance with the Rules of Canadian
Electrical Code.
This list is not all inclusive. Check with the
Authority Having Jurisdiction (AHJ) for any
local codes or standards which may be appli-
cable to your jurisdiction.
Owner’s Manual for Portable Generator 5
Section 2 General Information and Setup
Figure 2-1. Features and Controls
TABLE 1. Generator Components
Figure 2-2. Unit Identification Label
003442
003441
003436
22
27
12
20
15
14
26
23
19
14
21
10
16
24
18
25
13
17
28
1 120 Volt AC, 20 Amp Duplex Receptacle
2 120/240 Volt AC, 30 Amp Locking
Receptacle
3 1-pole Circuit Breakers (AC)
4 2-pole Circuit Breaker
5 120 Volt AC, 30 Amp Locking Receptacle
6 Idle Control
7 Ground Fault Sensing Module
8 GFCI Module Circuit Breaker
9 Hour Meter
10 Choke Lever
11 Start/Run/Stop Switch (Electric start)
(6.5kW, Run/Stop Switch, recoil start only)
12 Spark Plug
13 Oil Filter
14 Oil Drain
15 Oil Fill
16 Air Filter
17 Fuel Filter
18 Recoil Starter
19 Muffler
20 Spark Arrestor
21 Grounding Lug
22 Handles
23 Fuel Tank
24 Gas Cap
25 Fuel Gauge
26 Battery (if equipped)
27 Steel Lifting Pocket
28 Handle Release Knob
003447
6 Owner’s Manual for Portable Generator
Figure 2-3. XC Series Control Panel
Know Your Generator
Replacement owner’s manuals are available
at www.generac.com.
Emissions
The United States Environmental Protection
Agency (US EPA) (and California Air
Resources Board (CARB), for engines/equip-
ment certified to California standards) requires
that this engine/equipment complies with
exhaust and evaporative emissions stan-
dards. Locate the emissions compliance decal
on the engine to determine applicable stan-
dards. For emissions warranty information,
please reference the included emissions war-
ranty. It is important to follow the maintenance
specifications in the manual to ensure that the
engine complies with the applicable emissions
standards for the duration of the product’s life.
003439
4
3
6
11
5
1
9
82
7
(000100a)
WARNING
Consult Manual. Read and understand manual
completely before using product. Failure to
completely understand manual and product
could result in death or serious injury.
TABLE 2. Product Specifications
6.5 kW / 8.0 kW Generator Specifications
Rated Power @ 1.0 Power Factor 6.5kW** / 8.0kW**
Starting Watts 8.13kVA** / 10kVA**
Rated AC Voltage 120/240
Rated AC Load (120 Volt / 240 Volt)
6.5 kW
8.0 kW
54.2 / 27.1 Amps**
66.7 / 33.3 Amps**
Rated Frequency 60 Hz @ 3600 RPM
Phase Single Phase
Unit Weight (Dry)
6.5 kW (recoil start only)
6.5 kW (electric start)
8.0 kW (electric start)
246 lbs. (111.8 kg)
260 lbs. (117.9 kg)
** Operating Temperature Range: -18 deg. C (0 deg. F) to 40 Deg. C (104 Deg. F). When operated
above 25 deg. C (77 deg. F) there may be a decrease in power.
** Maximum wattage and current are subject to, and limited by, such factors as fuel Btu content, ambi-
ent temperature, altitude, engine condition, etc. Maximum power decreases about 3.5% for each
1,000 feet above sea level; and will also decrease about 1% for each 6° C (10° F) above 16° C (60°
F) ambient temperature.
Owner’s Manual for Portable Generator 7
Connection Plugs
120 VAC, 20 Amp, Duplex
Receptacle
The 120 Volt outlet is overload protected by a
20 Amp push-to-reset circuit breaker. See Fig-
ure 2-4. Each receptacle will power 120 Volt
AC, single phase, 60 Hz electrical loads
requiring up to 2400 watts (2.4 kW) or 20
Amps of current. Use only high quality, well-
insulated, 3-wire grounded cord sets rated for
125 Volts at 20 Amps (or greater).
Figure 2-4. 120 VAC, 20 Amp, Duplex
Receptacle NEMA 5-20R
120/240 VAC, 30 Amp Receptacle
Use a NEMA L14-30 plug with this receptacle
(rotate to lock/unlock). Connect a suitable 4-
wire grounded cord set to plug and desired
load. The cord set should be rated 250 Volts
AC at 30 Amps (or greater). See Figure 2-5.
Use this receptacle to operate 120 Volt AC,
60 Hz, single phase loads requiring up to
3600 watts (3.6 kW) of power at 30 Amps
or 240 Volt AC, 60 Hz, single phase loads
requiring up to 7200 watts (7.2 kW) of
power at 30 Amps. The outlet is protected
by a 2-pole 30 Amp rocker circuit breaker.
Figure 2-5. 120/240 VAC, 30 Amp Receptacle
NEMA L14-30R
120 VAC, 30 Amp Receptacle
Use a NEMA L5-30 plug with this receptacle
(rotate to lock/unlock). Connect a suitable 3-
wire cord set to the plug and to desired load.
The cord set should be rated for 125 Volts AC
at 30 Amps (or greater). See Figure 2-6.
Use this receptacle to operate 120 Volt AC,
60Hz, single phase loads requiring up to 3600
watts (3.6kW) of power at 30 Amps. The outlet
is protected by a 30 Amp push-to-reset circuit
breaker.
Figure 2-6. 120 VAC, 30 Amp Receptacle
NEMA L5-30
6.5 kW / 8.0 kW Engine Specifications
Displacement 426 cc
Spark Plug Part No. 0G0767B
Spark Plug Type Champion RC12YC or Equivalent
Spark Plug Gap 0.020 inch (0.51mm)
Gasoline Capacity 32 L (8.5 U.S. gallons)
Oil Type
See chart in
Add Engine Oil.
Oil Capacity
with filter change
without filter change
1.0 L (1.1 qt.)
0.9 L (0.95 qt.)
Run Time at 50% Load (6.5kW / 8.0kW) 14 Hours / 11 Hours
* Go to www.generac.com or contact an IASD for replacement parts.
TABLE 2. Product Specifications
000424
000204
000844
8 Owner’s Manual for Portable Generator
Hour Meter
The Hour Meter tracks hours of operation for
scheduled maintenance. See Figure 2-7.
The SVC display will illuminate one hour
before and one hour after each 200 hour
interval providing a two hour window to per-
form service.
When the hour meter is in flash alert mode,
the maintenance message will alternate with
elapsed time in hours and tenths. The hours
will flash four times, then alternate with the
maintenance message four times until the
meter automatically resets.
200 hours - SVC — Change oil, oil filter, air
filter, fuel filter, and spark plug. Clean spark
arrestor screen. (Every 200 hrs)
NOTE: The hour glass icon will flash when the
engine is running. This signifies the meter is
recording hours of operation.
Figure 2-7. Hour Meter
Ground Fault Sensing Module
This unit is equipped with a ground fault circuit
interrupter (GFCI). This device meets applica-
ble federal, state and local codes. The ground
fault sensing module covers all receptacles.
In the event of a ground fault, the GFCI will trip
and stop the flow of electricity to prevent seri-
ous injury.
The GFCI constantly monitors electricity flow-
ing in a circuit. If current flowing through a cir-
cuit varies from what is returning, the GFCI
switches power off tripping the main circuit
breaker on the generator's control panel.
A GFCI does NOT protect against circuit over-
loads, short circuits, or shocks. Electric shock
can still occur if a person touches charged
electrical wires while standing on a non-con-
ducting surface, such as a wood floor.
Test the GFCI module before each use. See
Figure 2-8.
1. Start generator.
2. Plug a test lamp into duplex receptacle.
The lamp should be on.
3. Press TEST button on GFCI to trip the
device. The main breaker should ‘trip’.
This is indicated by movement of the actu-
ator handle to the OFF position.
4. This should stop the flow of electricity
making the lamp shut off. If the main
breaker does not ‘trip’, the GFCI is not
working and the generator should not be
used. Contact an IASD.
5. To restore the flow of electricity, set the
main breaker actuator handle to the ‘ON’
position. The handles should remain
latched in this position. If it does not, either
the GFCI or the main breaker is failing and
should be replaced. Contact an IASD.
6. This GFCI is protected against overload by
a 6.5kW, 30 Amp or 8.0kW, 35A/240V
main breaker.
7. The GFCI has Auto-Monitor and End-of-
Life indications with LED status lights.
Figure 2-8. Test the GFCI
Automatic Idle Control (if equipped)
This feature improves fuel economy. When
this switch is turned ON, the engine will run at
a normal fast governed engine speed when
electrical load is connected. When load is
removed, the engine will run at a reduced
speed. With the switch OFF, the engine con-
tinually runs at a normal fast engine speed.
Always have the switch OFF when starting
and stopping the engine. See Figure 2-8.
Remove Contents from Carton
1. Open carton completely by cutting each
corner from top to bottom.
2. Remove and verify carton contents prior to
assembly. Carton contents should contain
the following:
0000.0
000205
004285
Owner’s Manual for Portable Generator 9
TABLE 3. Accessories
3. Call Generac Customer Service at 1-888-
GENERAC (1-888-436-3722) with the unit
model and serial number for any missing
carton contents.
4. Record model, serial number, and date of
purchase on front cover of this manual.
Assembly
Call Generac Customer Service at 1-888-
GENERAC (1-888-436-3722) for any assem-
bly issues or concerns. Please have model
and serial number available.
The following tools are required to install the
accessory kit.
Screwdriver (1)
8mm Wrench (2)
13mm Wrench (2)
See Figure 2-9.
Install lifting pocket assembly as follows:
1. Install each halve of lifting pocket (3)
underneath frame and loosely assemble
with 45mm bolt (7) and nut (11) through
holes in frame.
2. Install 20mm bolt (10) and nut (11) through
top holes of lifting pocket halves.
3. Tighten all bolts securely.
4. Align each top cover (8) with bottom lifting
pocket (3) holes. Insert binding post (9)
barrel and secure with binding post screw
(9).
Figure 2-9. Steel Lifting Pocket Assembly
NOTE: The wheels are not intended for over-
the-road use.
See Figure 2-10.
Install wheels as follows:
1. Slide axle (5) through generator frame
axle holes.
2. Slide wheel (1) and one 5/8" flat washer
(6) onto axle.
3. Secure with hair pin (4). Repeat on oppo-
site side.
Install frame foot assembly as follows:
1. Align frame foot (2) with holes in frame
and secure with 45mm bolts (7).
Item Qty.
Main Unit 1
Owner’s Manual 1
Engine Manual 1
Quart SAE Oil 1
Oil Filter 1
Air Filter 1
Spark Plug 1
Spark Plug Wrench 1
Shop Towel 1
Top Cover (8) 2
Wheel (1) 2
Frame Foot (2) 2
Steel Lifting Pocket (3) 2
Hardware Bag Qty.
Hair Pin (4) 2
Axle (5) 1
5/8” Flat Washer (6) 2
45mm Bolt (7) 8
Binding Post Assembly (9) 2
20mm Bolt (10) 2
Nut (11) 6
(000100a)
WARNING
Consult Manual. Read and understand manual
completely before using product. Failure to
completely understand manual and product
could result in death or serious injury.
003759
3
11
11
10
7
8
9
9
10 Owner’s Manual for Portable Generator
Figure 2-10. Wheel and Foot Assembly
Battery Cable Connection (if
equipped)
The unit has been shipped with the battery
cables disconnected.
You will need two 8mm box wrenches to con-
nect the battery cables. See Figure 4-5.
1. Cut off cable ties securing battery cables
and remove red cover from battery termi-
nal.
2. First, connect the red cables to the positive
(+) battery terminal with the bolt and nut
supplied.
3. Make sure connections are secure and
slide rubber boot over the positive (+) bat-
tery terminal and connection hardware.
4. Connect the black cables to the negative
(-) battery terminal with the bolt and nut
supplied. Slide rubber boot over the neg-
ative (-) battery terminal and connection
hardware.
5. Make sure all connections are secure.
NOTE: If the battery is unable to start the
engine, charge it with an appropriate 12V
charger or manually start the generator and let
run until charged.
Add Engine Oil
1. Place generator on a level surface.
2. Verify oil fill area is clean.
3. Remove oil fill cap and wipe dipstick clean.
See Figure 2-11.
Figure 2-11. Remove Dipstick
4. Add recommended engine oil. Climate
determines proper engine oil viscosity.
See chart to select correct viscosity.
NOTE: Use petroleum based oil (supplied) for
engine break-in before using synthetic oil.
003448
2
7
5
6
1
3
4
(000167a)
CAUTION
Equipment damage. Do not make battery
connections in reverse. Doing so will result
in equipment damage.
(000135)
CAUTION
Engine damage. Verify proper type and quantity of
engine oil prior to starting engine. Failure to do so
could result in engine damage.
000115
Owner’s Manual for Portable Generator 11
.
NOTE: Some units have more than one oil fill
location. It is only necessary to use one oil fill
point.
5. Thread dipstick into oil filler neck. Oil level
is checked with dipstick fully installed.
6. See Figure 2-12. Remove dipstick and ver-
ify oil level is within safe operating range.
Figure 2-12. Safe Operating Range
7. Install oil fill cap/dipstick and hand-tighten.
Fuel
Fuel requirements are as follows:
Clean, fresh, unleaded gasoline.
Minimum rating of 87 octane/87 AKI (91
RON).
Up to 10% ethanol (gasohol) is acceptable
(where available; non-ethanol-premium fuel
is recommended).
DO NOT use E85.
DO NOT use a gas oil mix.
DO NOT modify engine to run on alternate
fuels. Stabilize fuel prior to storage.
1. Verify unit is OFF and cooled for a mini-
mum of two minutes prior to fueling.
2. Place unit on level ground in a well venti-
lated area.
3. Clean area around fuel cap and remove
cap slowly.
4. Slowly add recommended fuel. Do not fill
above inner lip (A). See Figure 2-13.
5. Install fuel cap.
Figure 2-13. Add Recommended Fuel
NOTE: Allow spilled fuel to evaporate before
starting unit.
IMPORTANT NOTE: It is important to pre-
vent gum deposits from forming in fuel
system parts such as the carburetor, fuel
hose or tank during storage. Alcohol-
blended fuels (called gasohol, ethanol or
methanol) can attract moisture, which
leads to separation and formation of acids
during storage. Acidic gas can damage the
fuel system of an engine while in storage.
To avoid engine problems, the fuel system
should be emptied before storage of 30
days or longer. See the Storage section.
Never use engine or carburetor cleaner
products in the fuel tank as permanent
damage may occur.
SAE 30
10W-30
Synthetic 5W-30
000399
003620
(000105)
DANGER
Explosion and Fire. Fuel and vapors are
extremely flammable and explosive. Add fuel
in a well ventilated area. Keep fire and spark
away. Failure to do so will result in death
or serious injury.
(000166b)
DANGER
Explosion and Fire. Do not overfill fuel tank. Fill to
1/2 inch from top of tank to allow for fuel expansion.
Overfilling may cause fuel to spill onto engine causing
fire or explosion, which will result in death or
serious injury.
000230
A
12 Owner’s Manual for Portable Generator
Section 3 Operation
Operation and Use Questions
Call Generac Customer Service at 1-888-
GENERAC (1-888-436-3722) with questions
or concerns about equipment operation and
maintenance.
Before Starting Engine
1. Verify engine oil level is correct.
2. Verify fuel level is correct.
3. Verify unit is secure on level ground, with
proper clearance and is outdoors in a well
ventilated area.
Prepare Generator for Use
Grounding the Generator When
Used as a Portable
The generator is equipped with a terminal for
the connection of a grounding electrode sys-
tem. Article 250.34 (A) does not require the
frame of the generator to be connected to a
grounding electrode system when the genera-
tor only supplies power to cord and plug con-
nected equipment through the receptacles on
the generator.
When the generator supplies power to a 3-
pole manual transfer switch or distribution
panel boards for temporary power, a ground-
ing electrode system shall be installed and
connected to the grounding electrode terminal
on the generator. See NEC 250.30, 250.34
and 250.52 for clarification. See Figure 3-1.
Neutral Bonded to Frame
Figure 3-1.Grounding the Generator
Special Requirements
Review all Federal and State Occupational
Safety and Health Administration (OSHA) reg-
ulations, local codes, and ordinances applica-
ble to the intended use of the generator.
Additional regulations may apply if the genera-
tor is used at a construction site.
Consult a qualified electrician, electrical
inspector, or the local agency having jurisdic-
tion for additional requirements that may be
unique to your area, such as whether the gen-
erator is required to be registered with local
utility.
Connecting the Generator to a
Building Electrical System
It is recommended to use a manual transfer
switch when connecting directly to a building
electrical system. Connecting a portable gen-
erator to a building electrical system must be
made in strict compliance with all national and
local electrical codes and laws, and be com-
pleted by a qualified electrician.
Asphyxiation. Running engines produce
carbon monoxide, a colorless, odorless,
poisonous gas. Carbon monoxide, if not
avoided, will result in death or serious injury.
(000103)
DANGER
(000179b)
DANGER
Asphyxiation. The exhaust system must be properly
maintained. Do not alter or modify the exhaust system
as to render it unsafe or make it noncompliant with
local codes and/or standards. Failure to do so will
result in death or serious injury.
WARNING
(000118a)
Risk of fire. Do not use generator without
spark arrestor installed. Failure to do so
could result in death or serious injury.
(000178a)
Asphyxiation. Always use a battery operated carbon
monoxide alarm indoors and installed according to
the manufacturer’s instructions. Failure to do so
could result in death or serious injury.
WARNING
(000110)
WARNING
Risk of Fire. Hot surfaces could ignite
combustibles, resulting in fire. Fire could
result in death or serious injury.
(000108)
WARNING
Hot Surfaces. When operating machine, do not
touch hot surfaces. Keep machine away from
combustibles during use. Hot surfaces could
result in severe burns or fire.
(000136)
CAUTION
Equipment and property damage. Disconnect electrical
loads prior to starting or stopping unit. Failure to do so
could result in equipment and property damage.
000227
Owner’s Manual for Portable Generator 13
Connecting Electrical Loads
DO NOT connect 240 Volt loads to 120 Volt
receptacles. DO NOT connect 3-phase loads
to generator. DO NOT connect 50 Hz loads to
generator.
Let engine stabilize and warm up for a few
minutes after starting.
Plug in and turn on the desired 120 or 240 Volt
AC, single phase, 60 Hz electrical loads.
Add up the rated watts (or amps) of all loads
to be connected at one time. This total should
not be greater than (a) the rated wattage/
amperage capacity of the generator or (b) cir-
cuit breaker rating of the receptacle supplying
the power. See Know Generator Limits.
Know Generator Limits
Overloading a generator can result in damage
to the generator and connected electrical
devices. Observe the following to prevent
overload:
Add up the total wattage of all electrical
devices to be connected at one time. This
total should NOT be greater than the gener-
ator's wattage capacity.
The rated wattage of lights can be taken
from light bulbs. The rated wattage of tools,
appliances, and motors can be found on a
data label or decal affixed to the device.
If the appliance, tool, or motor does not
give wattage, multiply volts times ampere
rating to determine watts (volts x amps =
watts).
Some electric motors, such as induction
types, require about three times more watts
of power for starting than for running. This
surge of power lasts only a few seconds
when starting such motors. Make sure to
allow for high starting wattage when select-
ing electrical devices to connect to the gen-
erator:
1. Figure the watts needed to start the largest
motor.
2. Add to that figure the running watts of all
other connected loads.
The Wattage Reference Guide is provided to
assist in determining how many items the gen-
erator can operate at one time.
NOTE: All figures are approximate. See data
label on appliance for wattage requirements.
Table 3. Wattage Reference Guide
Device Running
Watts
*Air Conditioner (12,000 Btu) 1700
*Air Conditioner (24,000 Btu) 3800
*Air Conditioner (40,000 Btu) 6000
Battery Charger (20 Amp) 500
Belt Sander (3") 1000
Chain Saw 1200
Circular Saw (6-1/2") 800 to 1000
*Clothes Dryer (Electric) 5750
*Clothes Dryer (Gas) 700
*Clothes Washer 1150
Coffee Maker 1750
*Compressor (1 HP) 2000
*Compressor (3/4 HP) 1800
*Compressor (1/2 HP) 1400
Curling Iron 700
*Dehumidifier 650
Disc Sander (9") 1200
Edge Trimmer 500
Electric Blanket 400
Electric Nail Gun 1200
Electric Range (per element) 1500
Electric Skillet 1250
*Freezer 700
*Furnace Fan (3/5 HP) 875
*Garage Door Opener 500 to 750
Hair Dryer 1200
Hand Drill 250 to 1100
Hedge Trimmer 450
Impact Wrench 500
Iron 1200
*Jet Pump 800
Lawn Mower 1200
Light Bulb 100
Microwave Oven 700 to 1000
*Milk Cooler 1100
Oil Burner on Furnace 300
Oil Fired Space Heater (140,000
Btu)
400
Oil Fired Space Heater (85,000 Btu) 225
Oil Fired Space Heater (30,000 Btu) 150
*Paint Sprayer, Airless (1/3 HP) 600
Paint Sprayer, Airless (hand-held) 150
14 Owner’s Manual for Portable Generator
Transporting/Tipping of the Unit
Do not store or transport the unit at an angle
greater than 15 degrees.
Starting Pull Start Engines
1. Unplug all electrical loads from the unit's
receptacles before starting engine.
2. Place generator on a level surface.
3. Rotate the fuel shut-off valve (A) counter-
clockwise to the ON (open) position. See
Figure 3-2.
4. Turn engine STOP/RUN switch to RUN.
See Table 1: Generator Components.
.
Figure 3-2.Engine Controls
5. Slide engine choke lever (B) to Full
CHOKE position (left). See Figure 3-2.
6. See Figure 3-2. Firmly grasp recoil handle
(C) and pull slowly until increased resis-
tance is felt. Pull rapidly up and away.
7. When engine starts, move choke lever to
1/2 CHOKE position until engine runs
smoothly, then fully into OPEN (right) posi-
tion. If engine falters, move choke lever
back to 1/2-CHOKE position until engine
runs smoothly, then to OPEN (right) posi-
tion.
NOTE: If engine fires, but does not continue to
run, move choke lever to Full CHOKE (left)
and repeat starting instructions.
IMPORTANT NOTE: Do not overload gener-
ator or individual panel receptacles. These
outlets are overload protected with push-
to-reset circuit breakers. If amperage rat-
ing of any circuit breaker is exceeded, that
breaker opens and electrical output to that
receptacle is lost. Read Know Generator
Limits carefully.
Starting Electric Start Engines
1. Unplug all electrical loads from the unit's
receptacles before starting the engine.
2. Place generator on a level surface.
3. Rotate the fuel shut-off valve (A) counter-
clockwise to the ON (open) position. See
Figure 3-2.
4. Slide engine choke lever (B) to Full
CHOKE position (left). See Figure 3-2.
5. Turn and hold START/RUN/STOP switch
in the START position. When engine
starts, release the switch to the RUN posi-
tion.
6. When engine starts, move choke lever to
1/2 CHOKE position until engine runs
smoothly, then fully into OPEN (right) posi-
tion. If engine falters, move choke lever
back to 1/2-CHOKE position until engine
runs smoothly, then to OPEN (right) posi-
tion.
NOTE: If engine fires, but does not continue to
run, move choke lever to Full CHOKE (left)
and repeat starting instructions.
Radio 50 to 200
*Refrigerator 700
Slow Cooker 200
*Submersible Pump (1-1/2 HP) 2800
*Submersible Pump (1 HP) 2000
*Submersible Pump (1/2 HP) 1500
*Sump Pump 800 to 1050
*Table Saw (10") 1750 to 2000
Television 200 to 500
Toaster 1000 to 1650
Weed Trimmer 500
* Allow 3 times the listed watts for starting these
devices.
(000183)
WARNING
Recoil Hazard. Recoil could retract unexpectedly.
Kickback could result in death or serious injury.
(000136)
CAUTION
Equipment and property damage. Disconnect electrical
loads prior to starting or stopping unit. Failure to do so
could result in equipment and property damage.
003449
AC
OFFON
B
CLOSED
(000136)
CAUTION
Equipment and property damage. Disconnect electrical
loads prior to starting or stopping unit. Failure to do so
could result in equipment and property damage.
Owner’s Manual for Portable Generator 15
Generator Shut Down
1. Shut off all loads and unplug electrical
loads from generator panel receptacles.
2. Let engine run at no-load for several min-
utes to stabilize internal temperatures of
engine and generator.
3. Move START/RUN/STOP switch to STOP.
4. Rotate fuel shut-off valve clockwise to the
OFF (closed) position.
NOTE: Under normal conditions, close fuel
valve and allow generator to run carburetor
bowl out of fuel. For emergencies, switch to
STOP.
Low Oil Pressure Shutdown
System
The engine is equipped with a low oil pressure
sensor that shuts down the engine automati-
cally when the oil pressure drops below speci-
fications. The engine will not run until the oil
has been filled to the proper level.
If the engine shuts down and there is sufficient
fuel, check engine oil level.
(000136)
CAUTION
Equipment and property damage. Disconnect electrical
loads prior to starting or stopping unit. Failure to do so
could result in equipment and property damage.
16 Owner’s Manual for Portable Generator
Section 4 Maintenance and Troubleshooting
Maintenance
Regular maintenance will improve perfor-
mance and extend engine/equipment life.
Generac Power Systems, Inc. recommends
that all maintenance work be performed by an
Independent Authorized Service Dealer
(IASD). Regular maintenance, replacement,
or repair of the emissions control devices and
systems may be performed by any repair shop
or person of the owner’s choosing. To obtain
emissions control warranty service free of
charge, the work must be performed by an
IASD. See the emissions warranty.
NOTE: Call 1-888-GENERAC (1-888-436-
3722) with questions about component
replacement.
Maintenance Schedule
Follow maintenance schedule intervals,
whichever occurs first according to use.
NOTE: Adverse conditions will require more
frequent service.
NOTE: Go to Generac.com or contact an
IASD for replacement parts.
NOTE: All required service and adjustments
should be each season as detailed in the fol-
lowing chart.
Preventive Maintenance
Dirt or debris can cause improper operation
and equipment damage. Clean generator
daily or before each use. Keep area around
and behind muffler free from combustible
debris. Inspect all cooling air openings on
generator.
Use a damp cloth to wipe exterior surfaces
clean.
Use a soft bristle brush to loosen caked on
dirt, oil, etc.
Use a vacuum to pick up loose dirt and
debris.
Low pressure air (not to exceed 25 psi)
may be used to blow away dirt. Inspect
cooling air slots and openings on generator.
These openings must be kept clean and
unobstructed.
NOTE: DO NOT use a garden hose to clean
generator. Water can enter engine fuel system
and cause problems. If water enters generator
through cooling air slots, some water will be
retained in voids and crevices of rotor and sta-
tor winding insulation. Water and dirt buildup
on generator internal windings will decrease
insulation resistance of windings.
Engine Maintenance
Engine Oil Recommendations
To maintain the product warranty, the engine
oil should be serviced in accordance with the
recommendations of this manual. For your
convenience, maintenance kits designed and
intended for use on this product are available
from the manufacturer that include engine oil,
oil filter, air filter, spark plug(s), a shop towel
and funnel. These kits can be obtained from
an Independent Authorized Service Dealer
(IASD).
At Each Use
Check engine oil level
Every 100 Hours or Every Season*
Clean spark arrestor screen
Every Season
Check valve clearance***
Every 200 Hours or Every Season
Change oil ǂ
Replace spark plug
Replace fuel filter
Inspect/clean air cleaner filter**
ǂ Change oil after first 25 hours of operation,
then every season.
* Change oil and oil filter every month when
operating under heavy load or in high tem-
peratures.
** Clean more often under dirty or dusty oper-
ating conditions. Replace air filter parts if
they cannot be adequately cleaned.
*** Check valve clearance and adjust if neces-
sary after first 50 hours of operation and
every 400 hours thereafter.
(000142a)
Personal injury. Do not insert any object through the
air cooling slots. Generator can start at any time and
could result in death, serious injury, and unit damage.
WARNING
(000141)
WARNING
Accidental start-up. Disconnect spark plug wires when
working on unit. Failure to do so could result in death
or serious injury.
Owner’s Manual for Portable Generator 17
.
Inspect Engine Oil Level
Inspect engine oil level prior to each use, or
every 8 hours of operation.
1. Place generator on a level surface.
2. Clean area around oil fill.
3. See Figure 4-1. Remove oil fill cap and
wipe dipstick clean.
Figure 4-1. Engine Oil Fill
4. Screw dipstick into filler neck. Remove
dipstick and verify oil level is within safe
operating range. See Figure 4-2.
Figure 4-2. Safe Operating Range
5. Add recommended engine oil as neces-
sary.
6. Replace oil fill cap and hand-tighten.
NOTE: Some units have more than one oil fill
location. It is only necessary to use one oil fill
point.
Change Engine Oil and Oil Filter
When using generator under extreme, dirty,
dusty conditions, or in extremely hot weather,
change oil more frequently.
NOTE: Don’t pollute. Conserve resources.
Return used oil to collection centers.
Change oil while engine cool as follows:
1. Place generator on a level surface.
2. Disconnect the spark plug wire from the
spark plug and place the wire where it
cannot contact spark plug.
3. Clean area around oil fill, and oil drain
plug.
4. Remove oil fill cap.
5. Remove oil drain hose cap and drain oil
completely into a suitable container.
6. Install oil drain hose cap and tighten
securely.
7. Place a suitable container beneath the oil
filter and turn filter counterclockwise to
remove. Discard according to local regula-
tions.
8. Coat gasket of new filter with clean engine
oil. Turn filter clockwise until gasket con-
tacts lightly with filter adapter. Then tighten
an additional 3/4 turn.
9. Slowly pour oil into oil fill opening until oil
level is in safe operating range on dipstick.
DO NOT overfill.
10. Install oil fill cap, and finger tighten.
11. Wipe up any spilled oil.
12. Properly dispose of oil in accordance with
all applicable regulations.
Air Filter
Engine will not run properly and may be dam-
aged if run with a dirty air filter. Service air fil-
ter more frequently in dirty or dusty conditions.
To service air filter:
1. See Figure 4-3. Remove air filter cover (A)
and filter (B).
2. Gently tap filter on a solid surface. If too
dirty, replace with new filter.
3. Clean air filter cover before installation.
NOTE: To order a new air filter, contact the
nearest IASD at 1-888-GENERAC (1-888-
436-3722).
SAE 30
10W-30
Synthetic 5W-30
000399
(000139)
WARNING
Risk of burns. Allow engine to cool before
draining oil or coolant. Failure to do so could
result in death or serious injury.
000115
003620
(000141)
WARNING
Accidental start-up. Disconnect spark plug wires when
working on unit. Failure to do so could result in death
or serious injury.
(000139)
WARNING
Risk of burns. Allow engine to cool before
draining oil or coolant. Failure to do so could
result in death or serious injury.
18 Owner’s Manual for Portable Generator
Figure 4-3. Air Filter Assembly
Service Spark Plug
To service spark plug:
1. Clean area around spark plug.
2. Remove and inspect spark plug.
3. Inspect electrode gap with wire feeler
gauge and reset spark plug gap to 0.020
in (0.51 mm). See Figure 4-4.
Figure 4-4. Spark Plug
NOTE: Replace spark plug if electrodes are
pitted, burned or porcelain is cracked. Use
ONLY recommended replacement plug. See
Specifications.
4. Install spark plug finger tight, and tighten
an additional 3/8 to 1/2 turn using spark
plug wrench.
Battery Replacement (if
applicable)
NOTE: The battery shipped with the generator
has been fully charged. A battery may lose
some charge when not in use for prolonged
periods of time. The battery may have to be
charged before the first use. Running the gen-
erator will charge battery.
See Figure 4-5.
1. Disconnect and remove the battery con-
necting hardware (8mm) and BLACK wire
(B) from the battery’s NEGATIVE (-) termi-
nal.
2. Remove the red rubber boot (A) and dis-
connect the battery connecting hardware
(8mm) and RED wire (C) from the bat-
tery’s POSITIVE (+) terminal.
3. Install new battery. Secure battery with
strap.
4. Connect RED wire to the POSITIVE (+)
battery terminal (C). Slide rubber boot (A)
over connection hardware.
5. Connect BLACK wire to the NEGATIVE (-)
battery terminal (B).
Figure 4-5. Battery Connection
Inspect Muffler and Spark
Arrester
NOTE: It is a violation of California Public
Resource Code, Section 4442, to use or oper-
ate the engine on any forest-covered, brush-
covered, or grass-covered land unless the
exhaust system is equipped with a spark
arrester, as defined in Section 4442, main-
tained in effective working order. Other states
or federal jurisdictions may have similar laws.
Contact original equipment manufacturer,
retailer, or dealer to obtain a spark arrester
designed for exhaust system installed on this
engine.
NOTE: Use ONLY original equipment replace-
ment parts.
Inspect muffler for cracks, corrosion, or other
damage. Remove spark arrester, if equipped,
inspect for damage or carbon blockage.
Replace parts as required.
003466
A
B
000211
(000130)
WARNING
Accidental Start-up. Disconnect the negative battery
cable, then the positive battery cable when working
on unit. Failure to do so could result in death
or serious injury.
003760
A
C
B
WARNING
Environmental Hazard. Always recycle batteries at an
official recycling center in accordance with all local
laws and regulations. Failure to do so could result in
environmental damage, death or serious injury.
(000228)
Owner’s Manual for Portable Generator 19
Inspect Spark Arrester Screen
1. Loosen clamp (A). See Figure 4-6.
2. Inspect cone (C) and replace if torn, perfo-
rated or otherwise damaged. If cone is not
damaged, clean with commercial solvent.
3. Replace spark arrestor cone (C) and collar
(B). Secure with clamp (A).
Figure 4-6. Spark Arrestor Screen
Valve Clearance
Important: Please contact an Independent
Authorized Service Dealer for service assis-
tance. Proper valve clearance is essential for
prolonging the life of the engine.
Check valve clearance after the first fifty-hours
of operation. Adjust as necessary.
Intake — 0.05 to 0.08 mm (0.002" to 0.003"
inch)
Exhaust — 0.05 to 0.08 mm (0.002" to
0.003" inch)
Storage
General
It is recommended to start and run the genera-
tor for 30 minutes, every 30 days. If this is not
possible, refer to the following list to prepare
unit for storage.
DO NOT place a storage cover on a hot
generator. Allow unit to cool to room tem-
perature before storage.
DO NOT store fuel from one season to
another unless properly treated.
Replace fuel container if rust is present.
Rust in fuel will cause fuel system prob-
lems.
Cover unit with a suitable protective, mois-
ture resistant cover.
Store unit in a clean and dry area.
Always store generator and fuel away from
heat and ignition sources.
Prepare Fuel System for Storage
Fuel stored over 30 days can go bad and
damage fuel system components. Keep fuel
fresh, use fuel stabilizer.
If fuel stabilizer is added to fuel system, pre-
pare and run engine for long term storage.
Run engine for 10-15 minutes to circulate sta-
bilizer throughout fuel system. Adequately
prepared fuel can be stored up to 24 months.
NOTE: If fuel has not been treated with fuel
stabilizer, it must be drained into an approved
container. Run engine until it stops from lack
of fuel. Use of fuel stabilizer in fuel storage
container is recommended to keep fuel fresh.
1. Change engine oil.
2. Remove spark plug.
3. Pour tablespoon (5-10cc) of clean engine
oil or spray a suitable fogging agent into
cylinder.
4. Pull starter recoil several times to distrib-
ute oil in cylinder.
5. Install spark plug.
6. Pull recoil slowly until resistance is felt.
This will close valves so moisture cannot
enter engine cylinder. Gently release
recoil.
Change Oil
Change engine oil before storage. See
Change Engine Oil and Oil Filter.
(000108)
WARNING
Hot Surfaces. When operating machine, do not
touch hot surfaces. Keep machine away from
combustibles during use. Hot surfaces could
result in severe burns or fire.
003467
A
B
C
(000143)
DANGER
Explosion and Fire. Fuel and vapors are extremely
flammable and explosive. Store fuel in a well
ventilated area. Keep fire and spark away. Failure
to do so will result in death or serious injury.
(000109)
WARNING
Risk of Fire. Verify machine has properly
cooled before installing cover and storing
machine. Hot surfaces could result in fire.
(000181)
WARNING
Vision Loss. Eye protection is required to avoid
spray from spark plug hole when cranking engine.
Failure to do so could result in vision loss.
20 Owner’s Manual for Portable Generator
Troubleshooting
PROBLEM CAUSE CORRECTION
Engine is running, but
AC output is not
available.
1. Circuit breaker OPEN.
2. Poor connection or defective
cord set.
3. Connected device is bad.
4. Fault in generator.
5. GFCI breaker module is
OPEN.
1. Reset circuit breaker.
2. Check and repair.
3. Connect another device that is
in good condition.
4. Contact IASD.
5. Correct ground fault and press
reset button on GFCI breaker
module.
Engine runs well at
no-load, but bogs when
load is applied.
1. Short circuit in a connected
load.
2. Generator is overloaded.
3. Engine speed is too slow.
4. Shorted generator circuit.
5. Dirty fuel filter.
6. Clogged spark arrestor.
1. Disconnect shorted electrical
load.
2. See
Know Generator Limits.
3. Contact IASD.
4. Contact IASD.
5. Replace fuel filter.
6. Clean spark arrestor screen.
Engine will not start; or
starts and runs rough.
1. Fuel shut-off is OFF.
2. Dirty air filter.
3. Out of fuel.
4. Stale fuel.
5. Spark plug wire not connected
to spark plug.
6. Bad spark plug.
7. Water in fuel.
8. Overchoking.
9. Low oil level.
10. Excessive rich fuel mixture.
11. Intake valve stuck open or
closed.
12. Engine lost compression.
13. Dirty fuel filter.
1. Turn fuel shut-off ON.
2. Clean or replace air filter.
3. Fill fuel tank.
4. Drain fuel tank and fill with
fresh fuel.
5. Connect wire to spark plug.
6. Replace spark plug.
7. Drain fuel tank; fill with fresh
fuel.
8. Set choke to no choke posi-
tion.
9. Fill crankcase to correct level.
10. Contact IASD.
11. Contact IASD.
12. Contact IASD.
13. Replace fuel filter.
Engine shuts down
during operation.
1. Out of fuel.
2. Low oil level.
3. Fault in engine.
1. Fill fuel tank.
2. Fill crankcase to correct level.
3. Contact IASD.
Engine lacks power. 1. Load is too high.
2. Dirty air filter.
3. Engine needs to be serviced.
4. Dirty fuel filter.
5. Clogged spark arrestor.
1. Reduce load (see
Know Gen-
erator Limits).
2. Clean or replace air filter.
3. Contact IASD.
4. Replace fuel filter.
5. Clean spark arrestor screen.
Engine surges or
stumbles.
1. Choke is opened too soon.
2. Carburetor is running too rich
or too lean.
1. Set choke to halfway position
until engine runs smoothly.
2. Contact IASD.
Part No. 10000004327 Rev. B 05/14/2018
©2018 Generac Power Systems, Inc.
All rights reserved
Specifications are subject to change without notice.
No reproduction allowed in any form without prior
written consent from Generac Power Systems, Inc.
Generac Power Systems, Inc.
S45 W29290 Hwy. 59
Waukesha, WI 53189
1-888-GENERAC (1-888-436-3722)
www.generac.com/pro
Generador portátil serie XC
Manual del usuario
Registre su producto Generac en:
WWW.GENERAC.COM
1-888-GENERAC
(1-888-436-3722)
GUARDE ESTE MANUAL PARA PODER
CONSULTARLO EN EL FUTURO
003436
MODELO: __________________________
SERIE: ____________________________
FECHA DE LA COMPRA: _____________
ADVERTENCIA
(000209b
)
Fallecimiento. Este producto no se ha diseñado
para que se utilice en aplicaciones de apoyo
vital crítico. En caso de hacerlo, podría
provocar la muerte o lesiones graves.
Índice de contenidos
Sección 1 Introducción y
seguridad ....................................... 1
Introducción ..................................... 1
Normas de seguridad ...................... 1
Símbolos de seguridad y
significados ..................................... 1
Peligros derivados de las emisiones
de escape y la ubicación ................. 2
Peligros eléctricos ........................... 3
Peligros de incendio ........................ 3
Levantar o colgar el generador ....... 3
Índice de normas ............................. 4
Sección 2 Información general
y configuración ............................. 5
Conozca su generador .................... 6
Emisiones ........................................ 6
Enchufes de conexión ..................... 7
Contador de horas .......................... 8
Sacar el contenido de la caja .......... 9
Montaje ........................................... 9
Conexión del cable de la batería
(si se incluye) ................................ 10
Añadir aceite de motor .................. 10
Combustible .................................. 11
Sección 3 Funcionamiento ......... 13
Preguntas sobre uso y
funcionamiento .............................. 13
Antes de arrancar el motor ............ 13
Preparación del generador
para su uso ................................... 13
Conexión a tierra del generador
cuando se utiliza como aparato
portátil ........................................... 13
Conozca los límites del
generador ..................................... 14
Transporte o inclinación de
la unidad ....................................... 15
Arranque de motores con el
tirador de arranque ....................... 15
Arranque de motores con
arranque eléctrico ......................... 16
Apagar el generador ..................... 16
Sistema de cierre por nivel
bajo de aceite ............................... 16
Sección 4 Mantenimiento y
solución de problemas ............... 17
Mantenimiento .............................. 17
Programa de mantenimiento ........ 17
Mantenimiento preventivo ............. 17
Mantenimiento del motor .............. 18
Sustitución de la batería
(si procede) ................................... 19
Inspección del silenciador y
del dispositivo antichispas ............ 20
Holgura de la válvula .................... 20
Almacenamiento ........................... 21
Solución de problemas ................. 22
Notas ............................................ 24
(000393a)
ADVERTENCIA
PRODUCE CÁNCER Y
DAÑOS REPRODUCTIVOS
www.P65Warnings.ca.gov.
Manual del usuario del generador portátil 1
Sección 1 Introducción y seguridad
Introducción
Gracias por haber adquirido un producto de
Generac Power Systems Inc. Esta unidad se
ha diseñado para proporcionar un
funcionamiento eficiente, de alto rendimiento
y con una vida útil larga si se conserva
adecuadamente.
Si no entendiera alguno de los apartados de
este manual, póngase en contacto con el
servicio técnico independiente autorizado
más cercano, o con el servicio de atención al
cliente de Generac llamando al 1-888-
GENERAC (1-888-436-3722), o visitando
www.generac.com para plantear cualquier
pregunta o duda que tenga.
El propietario es responsable del manteni-
miento adecuado y del uso seguro del equipo.
Antes de poner en funcionamiento, revisar o
guardar el generador:
Revise atentamente todas las advertencias
que aparecen en este manual y en el
producto.
Familiarícese con este manual y con la
unidad antes de utilizarla.
Consulte la sección Montaje del manual
para obtener instrucciones sobre los
procedimientos de montaje final. Siga
estrictamente las instrucciones.
Guarde estas instrucciones para consultarlas
en el futuro. Entregue SIEMPRE este manual
a cualquier persona que utilice la máquina.
La información que aparece en este manual
es precisa y está basada en productos
fabricados en el momento en el que se editó
esta publicación. El fabricante se reserva el
derecho de hacer las actualizaciones
técnicas, las correcciones y las revisiones de
los productos que considere necesarias sin
previo aviso.
Normas de seguridad
El fabricante no puede prever todas las
posibles circunstancias que pueden suponer
un peligro. Las alertas que aparecen en este
manual, y en las etiquetas y los adhesivos
pegados en la unidad no incluyen todos los
peligros. Si se utiliza un procedimiento,
método de trabajo o técnica de funciona-
miento no recomendados específicamente
por el fabricante, compruebe que sean
seguros para otros usuarios y que no pongan
en peligro el equipo.
En esta publicación y en las etiquetas y
adhesivos pegados en la unidad, los bloques
PELIGRO, ADVERTENCIA, PRECAUCIÓN y
NOTA se utilizan para alertar al personal
sobre instrucciones especiales relacionadas
con un funcionamiento que puede ser
peligroso si se realiza de manera incorrecta o
imprudente. Léalos atentamente y respete sus
instrucciones. Las definiciones de alertas son
las siguientes:
NOTA: Las notas incluyen información
adicional importante para un procedimiento y
se incluyen en el texto normal de este manual.
Estos avisos de seguridad no pueden eliminar
los peligros que indican. Para evitar
accidentes, es importante el sentido común y
el seguimiento estricto de las instrucciones
especiales cuando se realice la acción o la
operación de mantenimiento.
Símbolos de seguridad
y significados
ADVERTENCIA
(000100a)
Consulte el manual. Lea y comprenda completamente
el manual antes de usar el producto. No comprender
completamente el manual puede provocar la muerte o
lesiones graves.
(000001)
PELIGRO
Indica una situación peligrosa que, si no se evita, ocasionará la
muerte o lesiones graves.
(000002)
ADVERTENCIA
Indica una situación peligrosa que, si no se evita, podría
ocasionar la muerte o lesiones graves.
PRECAUCIÓN
Indica una situación de riesgo que, si no se evita, puede
producir lesiones leves o moderadas.
(000003)
¡PELIGRO!
Usar un generador en interiores LO PUEDE MATAR EN
MINUTOS.
Los gases de escape del generador contienen monóxido
de carbono. Este es un veneno que no se puede ver u oler.
NUNCA lo use dentro de una
casa o garaje, AUN si la
puerta y las ventanas se
encuentran abiertas.
Úselo únicamente en
EXTERIORES, y alejado
de ventanas, puertas y
ventilaciones.
000657
000657
2 Manual del usuario del generador portátil
Si empieza a sentirse enfermo, mareado o
débil después de que el generador haya
estado funcionando, salga INMEDIATA-
MENTE para respirar aire fresco. Visite un
médico ya que podría haberse intoxicado
con monóxido de carbono.
Por razones de seguridad, se recomienda
que el mantenimiento de este equipo sea
efectuado por un distribuidor autorizado
independiente. Revise el generador regu-
larmente y póngase en contacto con el
servicio técnico autorizado independiente
más cercano para reparar o sustituir los
componentes que sea necesario.
Peligros derivados de las
emisiones de escape y la
ubicación
PELIGRO
Asfixia. Los motores funcionando producen
monóxido de carbono, un gas incoloro, inodoro, y
venenoso. El monóxido de carbono, si no se evita,
ocasionará la muerte o lesiones graves.
(000103)
(000179b)
PELIGRO
Asfixia. El sistema de escape debe mantenerse
adecuadamente. No altere ni modifique el sistema
de escape ya que podría hacer que su funcionamiento
sea inseguro o que no cumpla con los códigos y/o
normativas locales. En caso de no hacerlo, podría
provocarse la muerte o lesiones graves.
(000104)
PELIGRO
Electrocución. Si no se evita el contacto del agua
con una fuente de alimentación, ocasionará la
muerte o lesiones graves.
(000116)
Electrocución. APAGUE el suministro de alimentación
de emergencia y de la red eléctrica antes de conectar
la fuente de alimentación y las líneas de carga.
En caso de no hacerlo, podría provocar la
muerte o lesiones graves.
PELIGRO
ADVERTENCIA
Daños a los equipos y la propiedad. No altere la
construcción, instalación, o bloquee la ventilación
para el generador. No hacer esto puede provocar el
funcionamiento inseguro o dañar el generador.
(000146)
(000178a)
ADVERTENCIA
Asfixia. En interiores, utilice siempre una alarma de
monóxido de carbono alimentada por pilas e instalada
de acuerdo con las instrucciones de los fabricantes.
En caso de no hacerlo, podría provocarse
la muerte o lesiones graves.
(000250)
Daños a los equipos y a la propiedad. No use la unidad sobre
superficies desniveladas, o en zonas con exceso de humedad,
suciedad, polvo, o vapores corrosivos. Hacerlo puede ocasionar
la muerte, lesiones graves y daños al equipo.
ADVERTENCIA
ADVERTENCIA
(000111)
Piezas en movimiento. Mantenga la ropa, cabello,
y extremidades alejados de las piezas en
movimiento. No hacerlo puede ocasionar la
muerte o lesiones graves.
ADVERTENCIA
(000108)
Superficies calientes. Al usar la máquina, no toque las
superficies calientes. Mantenga la máquina alejada
de los combustibles durante el uso. Las superficies
calientes pueden ocasionar quemaduras
graves o incendio.
(000142a)
ADVERTENCIA
Lesiones personales. No inserte objetos a través de las ranuras
de enfriamiento de la unidad. El generador puede arrancar en
cualquier momento y provocar la muerte, lesiones graves y
daños en la unidad.
(000215)
ADVERTENCIA
Riesgo de lesión. No opere ni proporcione servicio a esta máquina
si no está completamente alerta. La fatiga puede desvirtuar la
capacidad para proporcionar servicio a este equipo y puede
ocasionar la muerte o lesiones graves.
ADVERTENCIA
Lesiones o daños al equipo. No use el generador como
un escalón. Hacerlo puede ocasionar caídas, piezas
dañadas, funcionamiento inseguro del equipo, la muerte
o lesiones graves.
(000216)
000406
PELIGRO
Asfixia. Los motores funcionando producen
monóxido de carbono, un gas incoloro, inodoro, y
venenoso. El monóxido de carbono, si no se evita,
ocasionará la muerte o lesiones graves.
(000103)
(000179b)
PELIGRO
Asfixia. El sistema de escape debe mantenerse
adecuadamente. No altere ni modifique el sistema
de escape ya que podría hacer que su funcionamiento
sea inseguro o que no cumpla con los códigos y/o
normativas locales. En caso de no hacerlo, podría
provocarse la muerte o lesiones graves.
ADVERTENCIA
Daños a los equipos y la propiedad. No altere la
construcción, instalación, o bloquee la ventilación
para el generador. No hacer esto puede provocar el
funcionamiento inseguro o dañar el generador.
(000146)
Manual del usuario del generador portátil 3
Si empieza a sentirse enfermo, mareado o
débil después de que el generador haya
estado funcionando, salga INMEDIATA-
MENTE para respirar aire fresco. Consulte
con un médico ya que podría haberse
intoxicado con monóxido de carbono.
No ponga NUNCA en marcha el generador
en interiores o en áreas parcialmente
cerradas como, por ejemplo, garajes.
Use SOLAMENTE el generador en áreas
exteriores y lejos de ventanas, puertas,
ventilaciones, espacios de rastreo y en
áreas en las que no haya una ventilación
adecuada y se puedan acumular gases de
escape mortales.
Usar un ventilador o abrir una puerta no
proporciona la suficiente ventilación.
Coloque el sistema de escape del
silenciador lejos de la gente y de los
edificios habitados.
Peligros eléctricos
El Código Eléctrico Nacional (NEC por sus
siglas en inglés) exige que la estructura y
los componentes conductores de electri-
cidad del generador estén correctamente
conectados a una toma de tierra aprobada.
Es posible que los códigos eléctricos
locales también exijan una conexión a
tierra adecuada del generador. Consulte
con un electricista local cuáles son los
requisitos de conexión a tierra de su zona.
Peligros de incendio
No utilice el generador si los dispositivos
eléctricos conectados se sobrecalientan, si
se pierde la potencia eléctrica, si el motor o
el generador producen chispas o si se
detectan llamas o humo mientras la unidad
está funcionando.
Tenga un extintor cerca del generador en
todo momento.
Deje una distancia de al menos 5 pies
(1,5 m) en ambos laterales del generador
cuando esté en funcionamiento para evitar
que se produzca sobrecalentamiento o un
incendio.
Levantar o colgar el generador
(000178a)
ADVERTENCIA
Asfixia. En interiores, utilice siempre una alarma de
monóxido de carbono alimentada por pilas e instalada
de acuerdo con las instrucciones de los fabricantes.
En caso de no hacerlo, podría provocarse
la muerte o lesiones graves.
(000144)
PELIGRO
Electrocución. El contacto con cables, terminales y
conexiones peladas mientras el generador está
funcionando provocará la muerte o lesiones graves.
(000104)
PELIGRO
Electrocución. Si no se evita el contacto del agua
con una fuente de alimentación, ocasionará la
muerte o lesiones graves.
(000145)
PELIGRO
Electrocución. En caso de un accidente eléctrico, APAGUE
de inmediato la alimentación eléctrica. Use implementos no
conductores para liberar a la víctima del conductor. Aplique
primeros auxilios y obtenga ayuda médica. No hacerlo
ocasionará la muerte o lesiones graves.
ADVERTENCIA
Arranque accidental. Desconecte el cable negativo de
la batería, luego el cable positivo de la batería cuando
trabaje en la unidad. No hacerlo puede ocasionar la
muerte o lesiones graves.
(000130)
(000105)
PELIGRO
Explosión e incendio. El combustible y los vapores son
extremadamente inflamables y explosivos. Añada
combustible en una zona bien ventilada. Mantenga alejados
el fuego y las chispas. No hacerlo puede ocasionar la muerte
o lesiones graves.
PELIGRO
Explosión e incendio. No sobrepase el nivel del depósito de
combustible. Llene el depósito y deje sin llenar media pulgada de la
parte superior del mismo para que quede espacio para la expansión
del mismo. Si lo llena en exceso puede hacer que el combustible se
derrame en el motor provocando un incendio o explosión, lo cual
podría provocar la muerte o lesiones graves.
(000166b)
(000174)
PELIGRO
Riesgo de incendio. Deje que los derrames de
combustible se sequen completamente antes de
poner en marcha el motor. No hacerlo ocasionará
la muerte o lesiones graves.
(000142a)
ADVERTENCIA
Lesiones personales. No inserte objetos a través de las ranuras
de enfriamiento de la unidad. El generador puede arrancar en
cualquier momento y provocar la muerte, lesiones graves y
daños en la unidad.
ADVERTENCIA
Lesiones personales. Si no conecta de manera correcta los
cables de elevación, las cadenas o las cintas elevadoras, es
posible que pueda provocar daños en la propiedad, lesiones
graves o incluso la muerte.
(000346)
ADVERTENCIA
Lesiones personales. Si no utiliza cables, cadenas o cintas
con una capacidad nominal de 2000 lbs. (907 kg) de carga
de trabajo o una carga superior para levantar o colgar la
unidad, es posible que pueda provocar daños en la
propiedad, lesiones graves o incluso la muerte.
(000347)
Lesiones personales. No ponga nunca en funcionamiento
el generador mientras está colgado. Si lo hace, puede
ocasionar daños en la propiedad, lesiones graves o incluso
la muerte.
(000348)
ADVERTENCIA
Manual del usuario del generador portátil 4
Índice de normas
1. Asociación nacional de protección contra
incendios (NFPA, por sus siglas en inglés)
70: El CÓDIGO ELÉCTRICO NACIONAL
(NEC por sus siglas en inglés) disponible
en www.nfpa.org
2. Asociación nacional de protección contra
incendios (NFPA, por sus siglas en inglés)
5000: CÓDIGO DE SEGURIDAD Y
CONSTRUCCIÓN DE EDIFICIOS
disponible en www.nfpa.org
3. Código de Construcción Internacional
disponible en www.iccsafe.org
4. Manual de Cableado Agrícola disponible
en www.rerc.org, Rural Electricity
Resource Council P.O. Box 309
Wilmington, OH 45177-0309
5. ASAE EP-364.2 Instalación y manteni-
miento de energía eléctrica de emergencia
en granjas disponible en www.asabe.org,
Sociedad Americana de Ingenieros
Agrícolas y Biológicos, 2950 Niles Road,
St. Joseph, MI 49085
6. Seguridad y requisitos de funcionamiento
de los generadores portátiles ANSI/PGMA
G300 disponible en pgmaonline.com
7. CSA C22.2 100-14 Motores y generadores
eléctricos para su uso e instalación
siguiendo las normativas del Código
eléctrico canadiense.
Esta lista no incluye todas las normas
aplicables. Consulte con la autoridad que
tenga jurisdicción (AHJ, por sus siglas en
inglés) si existe cualquier código local o
normativa que pueda ser de aplicación en su
jurisdicción.
Lesiones personales. No utilice un gancho de elevación si
observa algún daño o alguna señal de corrosión. Si lo hace,
puede ocasionar daños en la propiedad, lesiones graves o
incluso la muerte.
(000349)
ADVERTENCIA
Lesiones personales. Utilice el gancho de elevación
siguiendo las instrucciones que se indican. Si no lo hace,
puede ocasionar daños en la propiedad, lesiones graves
o incluso la muerte.
(000350)
ADVERTENCIA
Lesiones personales. Compruebe que todos los
dispositivos de sujeción están bien apretados antes
de levantar la unidad. Si no lo hace, puede ocasionar
daños en la propiedad, lesiones graves
o incluso la muerte.
(000351)
ADVERTENCIA
5 Manual del usuario del generador portátil
Sección 2 Información general y configuración
Figura 2-1. Funciones y controles
TABLA 1. Componentes del
generador
Figura 2-2. Etiqueta de identificación
de la unidad
003442
003441
003436
22
27
12
20
15
14
26
23
19
14
21
10
16
24
18
25
13
17
28
1 Toma de corriente doble de 120 voltios
CA, 20 A
2 Toma de corriente de 120/240 voltios
CA 30 A con bloqueo
3 Disyuntores de 1 polo (CA)
4 Disyuntor de 2 polos
5 Toma de corriente con bloqueo de
120 Voltios CA, 30 A
6 Control de ralentí
7 Módulo de detección de fallo en el circuito
de tierra
8 Disyuntor del módulo de GFCI
9 Contador de horas
10 Palanca del cebador
11 Interruptor de Arranque/Marcha/Parada
(Arranque eléctrico) (6,5 kW, Arranque/
Marcha/Parada, solamente arranque
manual)
12 Bujía
13 Filtro de aceite
14 Drenaje del aceite
15 Llenado del aceite
16 Filtro de aire
17 Filtro del combustible
18 Arranque manual
19 Silenciador
20 Dispositivo antichispas
21 Terminal de tierra
22 Tiradores
23 Depósito de combustible
24 Tapón de la gasolina
25 Medidor de combustible
26 Ubicación de la batería (si la hubiese)
27 Soporte de elevación de acero
28 Perilla de desbloqueo del tirador
003447
Manual del usuario del generador portátil 6
Figura 2-3. Panel de control del Serie XC
Conozca su generador
En la Web de Generac (www.generac.com.)
puede encontrar manuales del usuario de
reemplazo.
Emisiones
La Agencia de Protección Ambiental (EPA) de
los EE. UU. (y la Junta de Recursos del Aire de
California [CARB] para los motores/equipos
certificados conforme a las normas de
California) requiere(n) que este motor/equipo
cumpla las normas para el escape y las
emisiones que se evaporan. Ubique en el motor
la etiqueta adhesiva sobre cumplimiento de las
normas referidas a emisiones para determinar
las normas correspondientes. Para información
sobre la garantía de emisiones, consulte la
garantía de emisiones que se incluye. Es
importante seguir las especificaciones de
mantenimiento del manual para garantizar que
el motor cumpla las normas de emisiones
aplicables durante la vida útil del producto.
003439
4
3
6
11
5
1
9
82
7
ADVERTENCIA
(000100a)
Consulte el manual. Lea y comprenda completamente
el manual antes de usar el producto. No comprender
completamente el manual puede provocar la muerte o
lesiones graves.
TABLA 2. Especificaciones del producto
Especificaciones del generador de 6,5 kW / 8,0 kW
Potencia nominal en un factor de potencia de 1,0 6,5kW** / 8,0kW**
Vatios de arranque 8,13kW** / 10kW**
Tensión de CA nominal 120/240
Carga de CA nominal (120 voltios / 240 voltios)
6,5 kW
8,0 kW
54,2 / 27,1 Amperios**
66,7 / 33,3 Amperios**
Frecuencia nominal 60 Hz a 3600 RPM
Fase Monofásico
Peso de la unidad (Seco)
6,5 kW (solamente arranque manual)
6,5 kW (arranque eléctrico)
8,0 kW (arranque eléctrico)
246 lbs. (111,8 kg)
260 lbs. (117,9 kg)
** Intervalo de temperaturas de funcionamiento: -18 ºC (0 ºF) a 40 ºC (104 ºF). Durante el funciona-
miento con temperaturas superiores a 25º C (77º F), es posible que la potencia disminuya.
** La potencia en vatios máxima está sujeta y limitada por, factores como el contenido de BTu del
combustible, la altitud, el estado del motor, etc. La potencia máxima disminuye un 3,5 % por cada
1.000 pies (304,8 metros) sobre del nivel del mar y también disminuye un 1% aproximadamente
por cada 6º C (10º F) por encima de los 16º C (60º F) de temperatura ambiente.
7 Manual del usuario del generador portátil
Enchufes de conexión
120 VCA, 20 A, Toma de corriente
doble
La toma de 120 voltios está protegida contra
sobrecarga con un disyuntor de 20 amperios
que se pulsa para reiniciarse. Consulte la
Figura 2-4. Cada toma alimentará cargas
eléctricas de 120 Voltios CA, monofásicas, de
60 Hz que requieran una corriente de
2400 vatios (2,4 kW) o 20 amperios. Utilice
solo cables de 3 conductores con conexión a
tierra, de alta calidad y bien aislados con una
capacidad nominal de 125 voltios con 20 A
(o superior).
Figura 2-4. Toma de corriente NEMA 5-20R de
120 VCA, 20 A
Toma de corriente de 120/240 VCA,
30 Amp
Utilice un enchufe NEMA L14-30 con esta
toma de corriente (girar para bloquear/desblo-
quear). Conecte un cable de 4 conductores
con conexión a tierra al enchufe y a la carga
deseada. La capacidad nominal del cable
debería ser de 250 VCA con 30 amperios (o
superior). Consulte la Figura 2-5.
Utilice esta toma de corriente para cargas
monofásicas de 120 VCA, 60 Hz, que
requieran un máximo de 3.600 vatios
(3,6 kW) de potencia con 30 A o cargas
monofásicas de 240 VCA, 60 Hz, que
requieran un máximo de 7.200 vatios
(7,2 kW) de potencia con 30 A. La toma
está protegida con un disyuntor de
balancín de 2 polos, 30 A.
Figura 2-5. Toma de corriente de 120/240 VCA,
30 A NEMA L14-30R
Toma de corriente de 120 VCA,
30 Amp
Utilice un enchufe NEMA L5-30 con esta toma
de corriente (girar para bloquear/desblo-
quear). Conecte un cable de 3 conductores
adecuado al enchufe y a la carga deseada. La
capacidad nominal del cable debería ser de
125 VCA con 30 A (o superior). Consulte la
Figura 2-6.
Utilice esta toma de corriente para cargas
monofásicas de 120 VCA, 60 Hz, que
requieran un máximo de 3.600 vatios (3,6 kW)
de potencia con 30 A. La toma está protegida
con un disyuntor de 30 A con botón de
reinicio.
Especificaciones del motor de 6,5 kW / 8,0 kW
Cilindrada 426 cc
Nº de pieza de la bujía 0G0767B
Tipo de electrodos de la bujía Champion RC12YC o equivalente
Separación de los electrodos de la bujía 0,020 pulgadas (0,51mm)
Capacidad del depósito de gasolina 32 L (8,5 galones)
Tipo de aceite
Consulte el gráfico en la sección
Añadir
aceite de motor.
Capacidad de aceite
con cambio de filtro
sin cambio de filtro
1,0 L (1,1 qt.)
0,9 L (0,95 qt.)
Tiempo de funcionamiento a 50% de carga (6,5/
8,0kW)
14 horas/11 horas
* Vaya a www.generac.com o póngase en contacto con un servicio técnico autorizado independiente
para solicitar piezas de repuesto.
TABLA 2. Especificaciones del producto
000424
000204
Manual del usuario del generador portátil 8
Figura 2-6. Toma de corriente de 120 VCA,
30 A NEMA L5-30
Contador de horas
El contador de horas realiza un seguimiento
de las horas de funcionamiento para el
mantenimiento programado. Consulte la
Figura 2-7.
La pantalla del mensaje SVC se iluminará
una hora antes y una hora después de
cada intervalo de 200 horas, propor-
cionando un plazo de dos horas para
realizar la tarea de mantenimiento.
Cuando el contador de horas esté en el modo
de alerta parpadeante, el mensaje de
mantenimiento siempre se alternará con el
tiempo transcurrido en horas y minutos. Las
horas parpadearán cuatro veces y, a
continuación, se alternarán con el mensaje de
mantenimiento cuatro veces hasta que el
medidor se restablezca automáticamente.
200 horas - SVC Cambiar aceite, filtro
de aceite, filtro de combustible o bujía.
Limpiar la pantalla del supresor de chispas.
(Cada 200 horas)
NOTA: El icono del reloj de arena parpadeará
cuando el motor esté en funcionamiento. Esto
significa que el medidor está registrando las
horas de funcionamiento.
Figura 2-7. Contador de horas
Módulo de detección de fallo en el
circuito de tierra
Esta unidad incluye un interruptor del circuito
de fallo de conexión a tierra (GFCI). Este
dispositivo cumple con los códigos y
normativas locales, estatales y federales. El
módulo de detección de fallo en el circuito de
conexión a tierra es para todas las tomas.
En el caso de que se produzca un fallo de
conexión a tierra, el GFCI se activará y
detendrá la corriente eléctrica para evitar que
se produzcan lesiones graves.
El GFCI controla continuamente la corriente
del circuito. Si la corriente del circuito es
diferente a la corriente de retorno, el GFCI
desconecta la alimentación mediante la
activación del disyuntor principal en el panel
de control del generador.
Un GFCI NO protege de sobrecargas en el
circuito, cortocircuitos ni descargas eléctricas.
Una descarga eléctrica se puede producir
cuando una persona toca cables cargados
eléctricamente mientras se encuentra sobre
una superficie no conductora, como por
ejemplo un suelo de madera.
Pruebe el módulo de GFCI antes de cada uso.
Consulte la Figura 2-8.
1. Arranque el generador.
2. Enchufe la lámpara de prueba en la toma
doble. La lampara debería encenderse.
3. Pulse el botón TEST (Prueba) en el GFCI
para activar el dispositivo. A continuación
el disyuntor principal debería “activarse”.
Esto se indica con el movimiento de la
palanca del accionador en la posición OFF.
4. De esta manera la corriente eléctrica se
detiene haciendo que la lámpara se
apague. Si el disyuntor principal no se
“activa”, esto significa que el GFCI no
funciona y el generador no debe utilizarse.
Póngase en contacto con el servicio
técnico autorizado independiente.
5. Para restaurar la corriente eléctrica,
coloque la palanca del accionador en la
posición 'ON'. La palanca debería
permanecer bloqueada en su posición. Si
no es así, bien el GFCI o bien el disyuntor
principal tienen algún fallo y deberán ser
reemplazados. Póngase en contacto con
el servicio técnico autorizado indepen-
diente.
6. Este GFCI está protegido contra
sobrecargas por un disyuntor principal de
6,5kW, 30 A o 8,0kW, 35A/240V.
7. El GFCI cuenta con luces de estado LED
para las funciones de Monitor automático
y Fin de la vida útil.
000844
0000.0
000205
9 Manual del usuario del generador portátil
Figura 2-8. Probar el GFCI
Control de ralentí automático
(si hubiese)
Esta función mejora el ahorro de combustible.
Cuando este interruptor se coloca en la
posición ON, el motor funcionará a una
velocidad de motor normal rápida cuando está
conectado a una carga eléctrica. Cuando se
retira la carga eléctrica, el motor funcionará a
una velocidad reducida. Con el interruptor en
la posición OFF, el motor funciona de manera
continua a una velocidad de motor normal
rápida. Coloque siempre el interruptor en la
posición OFF cuando arranque y pare el
motor. Consulte la Figura 2-8.
Sacar el contenido de la caja
1. Abra la caja de cartón completamente
cortando cada esquina de arriba a abajo.
2. Saque y compruebe el contenido de la
caja antes del montaje. La caja debe
contener lo siguiente:
TABLA 3. Accesorios
3. Si faltara algún artículo de su caja,
póngase en contacto con el servicio de
atención al cliente de Generac llamando al
1-888-436-3722 y cuando llame tenga a
mano los números de modelo y serie.
4. Escriba el número de modelo, número de
serie y fecha de compra que aparecen en
la portada de este manual.
Montaje
Si tiene problemas con el montaje, póngase
en contacto con el servicio de atención al
cliente de Generac llamando al 1-888-
GENERAC (1-888-436-3722). Cuando llame
para solicitar asistencia, tenga a mano los
números de modelo y de serie.
Las siguientes herramientas son necesarias
para instalar el kit de accesorios.
Destornillador (1)
Llave de 8 mm (2)
Llave de 13 mm (2)
Consulte la Figura 2-9.
Instale el soporte de elevación de la siguiente
manera:
1. Instale cada una de las mitades del
soporte de elevación (3) debajo de la
estructura y colóquelos fijando sin apretar
los tornillos de 45 mm (7) y la tuerca (11) a
través de los orificios que hay en la
estructura.
2. Inserte el tornillo de 20 mm (10) y la tuerca
(11) en los agujeros superiores de las dos
mitades del soporte de elevación.
3. Apriete todos los tornillos hasta que
queden fijados.
4. Alinee cada una de las tapas superiores
(8) con los agujeros del soporte de
elevación inferior (3). Inserte el cilindro del
tornillo de conexión (9) y fíjelo con el
tornillo de conexión 89).
Artículo Ctd
Unidad principal 1
Manual del usuario 1
Manual del motor 1
Cuarto de aceite SAE 1
Filtro de aceite 1
Filtro de aire 1
Bujía 1
Llave de bujías 1
Toalla para uso industrial 1
Tapa superior (8) 2
Rueda (1) 2
Pata para la estructura (2) 2
Conjunto de elevación de acero (3) 2
004285
Bolsa de tornillería Ctd
Horquilla (4) 2
Eje (5) 1
Arandela plana 5/8” (6) 2
Tornillo de 54 mm (7) 8
Conjunto de tornillo de conexión (9) 2
Tornillo de 54 mm (10) 2
Tuerca (11) 6
ADVERTENCIA
(000100a)
Consulte el manual. Lea y comprenda completamente
el manual antes de usar el producto. No comprender
completamente el manual puede provocar la muerte o
lesiones graves.
Manual del usuario del generador portátil 10
Figura 2-9. Soporte de elevación de acero
NOTA: Las ruedas no se han diseñado para
su circulación sobre carreteras.
Consulte la Figura 2-10.
Instale las ruedas tal y como se indica a
continuación:
1. Deslice el eje (5) por los agujeros del eje
de la estructura del generador.
2. Deslice la rueda (1) y una arandela plana
de 5/8" (6) por el eje.
3. Sujételo con la horquilla (4). Repita este
procedimiento en el lado opuesto.
Instale el conjunto de patas para la estructura
de la siguiente manera:
1. Alinee la pata de la estructura (2) con los
agujeros de la estructura y fíjelas con
tornillos de 45 mm (7).
Figura 2-10. Ruedas y patas
Conexión del cable de la batería
(si se incluye)
La unidad se ha enviado con los cables de la
batería desconectados.
Necesitará dos llaves de tubo de 8 mm para
conectar los cables de la batería. Consulte la
Figura 4-5.
1. Corte las bridas de sujeción de los cables
de la batería y retire la cubierta roja del
borne de la batería.
2. En primer lugar, conecte los cables rojos
al borne positivo (+) de la batería con el
perno y la tuerca incluidos.
3. Compruebe que las conexiones estén bien
apretadas y coloque la funda de goma en
el borne positivo (+) de la batería y los
tornillos de conexión.
4. Conecte el cable negro al borne negativo
(-) de la batería con el perno y la tuerca
que se incluyen. Coloque la funda de
goma en el borne negativo (-) de la
batería y los tornillos de conexión.
5. Compruebe que todas las conexiones
sean seguras.
NOTA: Si no es posible arrancar el motor con
la batería, cámbielo por un cargador de 12V
adecuado o arranque el generador y deje que
funcione hasta que se cargue.
Añadir aceite de motor
1. Coloque el generador sobre una superficie
plana.
2. Verifique que el área de llenado de aceite
esté limpia.
003759
3
11
11
10
7
8
9
9
003448
2
7
5
6
1
3
4
PRECAUCIÓN
Daños en el equipo. No realice las conexiones
de la batería a la inversa. Si lo hace, el equipo
podría resultar dañado.
(000167a)
(000135)
Daño al motor. Verifique el tipo y la cantidad apropiados
del aceite del motor antes de poner en marcha el motor.
No hacer esto puede provocar daños al motor.
PRECAUCIÓN
11 Manual del usuario del generador portátil
3. Retire la tapa de llenado de aceite y
limpie la varilla de medición. Consulte la
Figura 2-11.
Figura 2-11. Sacar la varilla
4. Añada el aceite de motor recomendado.
Las temperaturas exteriores determinan la
viscosidad adecuada del aceite para el
motor. Use esta tabla para seleccionar la
mejor viscosidad.
NOTA: Use aceite a base de petróleo
(incluida) para facilitar el rodaje del motor
antes de utilizar aceite sintético.
.
NOTA: Algunas unidades cuentan con más de
un lugar por el que se puede añadir el aceite.
En estos casos, solo se necesita utilizar un
punto de llenado de aceite.
5. Introduzca la varilla en el cuello de llenado
de aceite. El nivel de aceite se comprueba
con la varilla de medición completamente
insertada.
6. Consulte la Figura 2-12. Retire la varilla y
compruebe que el nivel de aceite se
encuentra dentro del rango de
funcionamiento seguro.
Figura 2-12. Rango de funcionamiento seguro
7. Coloque la tapa de llenado del aceite/
varilla de nivel y apriétela firmemente con
la mano.
Combustible
El combustible debe cumplir con los
siguientes requisitos:
Gasolina limpia, en buen estado y sin
plomo.
Un octanaje mínimo de 87/87 AKI (RON 91).
También se puede utilizar gasolina con un
porcentaje de hasta el 10% de etanol
(gasohol), cuando esté disponible, se
recomienda utilizar combustible premium
sin etanol.
NO use E85.
NO mezcle aceite en la gasolina.
NO modifique el motor para que funcione
con combustibles alternativos. Estabilice el
combustible antes de almacenarlo.
1. Verifique que la unidad está apagada y
espere a que se enfríe un mínimo de dos
minutos antes de cargar el combustible.
2. Coloque la unidad sobre una superficie
nivelada y en un área bien ventilada.
3. Limpie el área alrededor de la tapa del
combustible y quite la tapa con cuidado.
4. Añada lentamente el combustible reco-
mendado. No llene por encima del borde
interno. Consulte la Figura 2-13.
5. Colocación de la tapa del combustible.
Figura 2-13. Añadir combustible
recomendado
NOTA: Si se derrama combustible, espere
hasta que se evapore antes de encender el
motor.
000115
SAE 30
10W-30
5W-30 sintético
Intervalo de temperatura de uso esperada
000399
003620
(000105)
PELIGRO
Explosión e incendio. El combustible y los vapores son
extremadamente inflamables y explosivos. Añada
combustible en una zona bien ventilada. Mantenga alejados
el fuego y las chispas. No hacerlo puede ocasionar la muerte
o lesiones graves.
PELIGRO
Explosión e incendio. No sobrepase el nivel del depósito de
combustible. Llene el depósito y deje sin llenar media pulgada de la
parte superior del mismo para que quede espacio para la expansión
del mismo. Si lo llena en exceso puede hacer que el combustible se
derrame en el motor provocando un incendio o explosión, lo cual
podría provocar la muerte o lesiones graves.
(000166b)
000230
A
Manual del usuario del generador portátil 12
NOTA IMPORTANTE: Es importante evitar la
formación de acumulaciones de residuos
pegajosos en los componentes del sistema
de combustible como el carburador, la
manguera o el depósito durante el
almacenamiento. Los combustibles mez-
clados con alcohol (gashol, etanol o
metanol) pueden atraer la humedad, lo que
provoca la separación y la formación de
ácidos durante el almacenamiento. El gas
ácido puede dañar el sistema de
combustible de un motor durante el
almacenamiento. Para evitar problemas con
el motor, debería vaciar el sistema de
combustible antes de almacenarlo durante
30 días o más. Consulte la sección
Almacenamiento. Nunca utilice productos
para la limpieza del motor o carburador en
el depósito de combustible ya que podrían
provocar daños permanentes.
Manual del usuario del generador portátil 13
Sección 3 Funcionamiento
Preguntas sobre uso y
funcionamiento
Si tiene preguntas o dudas acerca del
funcionamiento y mantenimiento del equipo,
póngase en contacto con el servicio de
atención al cliente de Generac llamando al
1-888-GENERAC (1-888-436-3722).
Antes de arrancar el motor
1. Verifique que el nivel de aceite del motor
sea el correcto.
2. Verifique que el nivel del combustible sea
el correcto.
3. Verifique que la unidad esté segura sobre
una superficie nivelada, en un espacio
exterior y en una zona bien ventilada.
Preparación del generador para
su uso
Conexión a tierra del generador
cuando se utiliza como aparato
portátil
El generador está equipado con un terminal
para la conexión de un sistema de electrodos de
conexión a tierra. Article 250.34 (A) No se
requiere que la estructura del generador se
conecte a un sistema de electrodos de conexión
a tierra cuando el generador solamente
suministra alimentación a un equipo conectado
mediante enchufe y cable de alimentación a
través de las tomas del generador.
Cuando el generador suministra energía a un
interruptor de transferencia manual de 3 polos o
a tableros de distribución eléctrica para
suministrar alimentación temporalmente, debe
instalarse un sistema de electrodos de
conexión a tierra y conectarse a una terminal de
electrodos de conexión a tierra en el generador.
Consulte NEC 250.30, 250.34 y 250.52 para
aclarar cualquier duda. Consulte la Figura 3-1.
Conexión neutral a estructura
Figura 3-1.Conexión a tierra del generador
Requisitos especiales
Revise todos los decretos, códigos locales o
normativas de la Administración de Seguridad
y Salud Ocupacional estatales o federales
(OSHA) que se apliquen al uso previsto del
generador. Es posible que se apliquen más
normativas si el generador se utiliza en una
obra.
Consulte a un electricista cualificado, un
inspector de instalaciones eléctricas o la
agencia local que tenga potestad para
imponer requisitos adicionales que puedan
ser específicos para su área, como por
ejemplo si es necesario que el generador esté
registrado con la empresa encargada de
suministrar la electricidad en su zona.
PELIGRO
Asfixia. Los motores funcionando producen
monóxido de carbono, un gas incoloro, inodoro, y
venenoso. El monóxido de carbono, si no se evita,
ocasionará la muerte o lesiones graves.
(000103)
(000179b)
PELIGRO
Asfixia. El sistema de escape debe mantenerse
adecuadamente. No altere ni modifique el sistema
de escape ya que podría hacer que su funcionamiento
sea inseguro o que no cumpla con los códigos y/o
normativas locales. En caso de no hacerlo, podría
provocarse la muerte o lesiones graves.
(000118a)
ADVERTENCIA
Riesgo de incendio. No use el generador sin el
supresor de chispas. De lo contrario, pueden
producirse lesiones graves o la muerte.
(000178a)
ADVERTENCIA
Asfixia. En interiores, utilice siempre una alarma de
monóxido de carbono alimentada por pilas e instalada
de acuerdo con las instrucciones de los fabricantes.
En caso de no hacerlo, podría provocarse
la muerte o lesiones graves.
ADVERTENCIA
(000110)
Riesgo de incendio. Las superficies calientes
pueden encender combustibles, produciendo un
incendio. El incendio puede ocasionar la muerte
o lesiones graves.
ADVERTENCIA
(000108)
Superficies calientes. Al usar la máquina, no toque las
superficies calientes. Mantenga la máquina alejada
de los combustibles durante el uso. Las superficies
calientes pueden ocasionar quemaduras
graves o incendio.
(000136)
PRECAUCIÓN
Daños a los equipos y la propiedad. Desconecte las cargas
eléctricas antes de poner en marcha o parar la unidad. No
hacer esto puede provocar daños al equipo y la propiedad.
000227
14 Manual del usuario del generador portátil
Conexión del generador al sistema
eléctrico de un edificio
Se recomienda usar un interruptor de
transferencia manual al conectar
directamente al sistema eléctrico de un
edificio. Para conectar un generador portátil al
sistema eléctrico de un edificio, deben
cumplirse estrictamente las normativas y la
legislación sobre instalaciones eléctricas
locales y nacionales, y esta conexión debe
realizarla un electricista cualificado.
Conexión de las cargas eléctricas
NO conecte cargas de 240 voltios a tomas de
120 voltios. NO conecte cargas trifásicas al
generador. NO conecte cargas de 50 Hz al
generador.
Deje que la unidad se estabilice y se caliente
durante unos minutos antes de arrancarla.
Enchufe y conecte las cargas eléctricas de
120 o 240 voltios de CA, monofásicas de
60 Hz.
Añada la potencia nominal (o amperios) de
todas las cargas que se conectarán a la vez.
El total no debe ser superior a (a) la
capacidad de voltaje/amperaje nominal del
generador o (b) la potencia del disyuntor de la
toma que suministra la energía. Consulte
Conozca los límites del generador.
Conozca los límites
del generador
Sobrecargar un generador en exceso puede
provocar daños en el generador y en los
dispositivos eléctricos conectados. Tenga en
cuenta lo siguiente para evitar sobrecargas:
Sume la potencia total de todos los
dispositivos eléctricos que se conectarán a
la vez. Este total NO debería superar la
potencia del generador.
La potencia nominal de las luces se puede
obtener de las bombillas. La potencia
nominal de las herramientas,
electrodomésticos y motores se encuentra
en la etiqueta o adhesivo de datos pegados
en el dispositivo.
Si los electrodomésticos, herramientas o
motores no indican la potencia, multiplique
los voltios por la capacidad nominal en
amperios para determinar los vatios (voltios
x amperios = vatios).
Algunos motores eléctricos, como los de
inducción, requieren tres veces más vatios
de potencia para el arranque que para el
funcionamiento. Esta sobrecarga sólo dura
unos pocos segundos al arrancar este tipo
de motores. Asegúrese de disponer de una
potencia de arranque elevada cuando
seleccione los dispositivos eléctricos que
se conectarán al generador.
1. Calcule los vatios necesarios para
arrancar el motor más grande.
2. Sume a esa cifra los vatios de
funcionamiento del resto de cargas
conectadas.
Hemos incluido la Guía de referencia de la
potencia para ayudarle a determinar el
número de dispositivos que el generador
puede hacer funcionar a la vez.
NOTA: Todas las cifras son aproximadas.
Consulte la etiqueta de datos del
electrodoméstico para obtener los requisitos
de potencia.
Tabla 3: Guía de referencia de la potencia
Dispositivo Vatios de
funciona-
miento
*Aire acondicionado (12.000 Btu) 1700
*Aire acondicionado (24.000 Btu) 3800
*Aire acondicionado (40.000 Btu) 6000
Cargador de batería (20 amperios) 500
Lijadora de correa (3") 1000
Motosierra 1200
Sierra circular (6-1/2") de 800 a 1000
*Secadora (eléctrica) 5750
*Secadora (gas) 700
*Lavadora 1150
Cafetera 1750
*Compresor (1 HP) 2000
*Compresor (3/4 HP) 1800
*Compresor (1/2 HP) 1400
Plancha para el pelo 700
Deshumidificador 650
Lijadora de disco (9") 1200
Cortabordes 500
Manta eléctrica 400
Pistola eléctrica para clavos 1200
Cocina eléctrica (por elemento) 1500
Sartén eléctrica 1250
*Congelador 700
*Extractor de humos (3/5 HP) 875
Sistema de apertura del garaje de 500 a 750
Secador de pelo 1200
Taladro de mano de 250 a 1100
Cortasetos 450
Llave de impacto 500
Plancha 1200
*Bomba de chorro 800
Cortacésped 1200
Bombilla 100
Manual del usuario del generador portátil 15
Transporte o inclinación de la
unidad
No almacene ni transporte la unidad con un
ángulo superior a 15 grados.
Arranque de motores con el
tirador de arranque
1. Desconecte todas las cargas eléctricas de
las tomas de corriente de la unidad antes
de arrancar el motor.
2. Coloque el generador sobre una superficie
plana.
3. Gire la válvula de cierre de combustible
(A) en el sentido contrario a las agujas del
reloj a la posición ON (Abierto). Consulte
la Figura 3-2.
4. Gire el interruptor de PARO/MARCHA del
motor a la posición RUN (Marcha).
Consulte la Tabla 1: Componentes del
generador.
.
Figura 3-2.Controles del motor
5. Mueva la palanca del cebador (B) a la
izquierda hasta la posición Full CHOKE
(Cebado completo). Consulte la Figura 3-2.
6. Consulte la Figura 3-2. Sujete la cuerda de
arranque (C) y tire de ella ligeramente
hasta que note que la resistencia
aumenta. Tire rápidamente hacia arriba y
hacia afuera.
7. Cuando el motor arranque, mueva la
palanca del cebador a la posición 1/2
CHOKE (Cebado medio) hasta que el
motor funcione de manera suave y, a
continuación, mueva la palanca hasta la
posición OPEN (derecha). Si el
funcionamiento del motor decae, mueva
de nuevo la palanca del cebador a la
posición 1/2-CHOKE (Cebado medio)
hasta que el motor funcione de manera
suave y, a continuación, mueva la palanca
hasta la posición OPEN (derecha).
NOTA: Si el motor arranca, pero no sigue
funcionando, mueva la palanca del cebador a
la posición Full CHOKE (Cebado completo) a
la izquierda y repita las instrucciones de
arranque.
NOTA IMPORTANTE: No sobrecargue el
generador ni las tomas de corriente
individuales del panel. Estas tomas están
protegidas contra sobrecargas con
disyuntores pulsar-para-reiniciar. Si se
supera el amperaje de alguno de los
disyuntores, el disyuntor afectado se
abrirá y se perderá la potencia eléctrica a
la toma de corriente. Lea detenidamente la
sección Conozca los límites del generador.
Horno microondas de 700 a 1000
*Enfriador de leche 1100
Quemador de petróleo en el horno 300
Estufa de petróleo (140.000 Btu) 400
Estufa de petróleo (85.000 Btu) 225
Estufa de petróleo (30.000 Btu) 150
*Pistola de pintar, sin aire (1/3 HP) 600
Pistola de pintar, sin aire (de mano) 150
Radio de 50 a 200
*Refrigerador 700
Olla de cocción lenta 200
*Bomba sumergible (1-1/2 HP) 2800
*Bomba sumergible (1 HP) 2000
*Bomba sumergible (1/2 HP) 1500
*Bomba de sumidero de 800 a 1050
*Sierra de mesa (10”) de 1750 a
2000
Televisión de 200 a 500
Tostadora de 1000 a
1650
Cortacésped de hilo 500
* Multiplique por 3 los vatios de la lista para calcular
los vatios necesarios para arrancar estos
dispositivos.
(000183)
ADVERTENCIA
Riesgo del arranque con cuerda. El arranque
con cuerda puede reaccionar inesperadamente.
El contragolpe puede ocasionar la muerte o
lesiones graves.
(000136)
PRECAUCIÓN
Daños a los equipos y la propiedad. Desconecte las cargas
eléctricas antes de poner en marcha o parar la unidad. No
hacer esto puede provocar daños al equipo y la propiedad.
003449
A
C
OFFON
B
CERRADO
16 Manual del usuario del generador portátil
Arranque de motores con
arranque eléctrico
1. Desconecte todas las cargas eléctricas de
las tomas de corriente de la unidad antes
de arrancar el motor.
2. Coloque el generador sobre una superficie
plana.
3. Gire la válvula de cierre de combustible
(A) en el sentido contrario a las agujas del
reloj a la posición ON (Abierto). Consulte
la Figura 3-2.
4. Mueva la palanca del cebador (B) a la
izquierda hasta la posición Full CHOKE
(Cebado completo). Consulte la Figura 3-2.
5. Mantenga pulsado el interruptor de
ARRANQUE/MARCHA/PARADA en la
posición START (Arranque). Cuando el
motor arranque, suelte el interruptor a la
posición RUN (Marcha).
6. Cuando el motor arranque, mueva la
palanca del cebador a la posición 1/2
CHOKE (Cebado medio) hasta que el
motor funcione de manera suave y, a
continuación, mueva la palanca hasta la
posición OPEN (derecha). Si el
funcionamiento del motor decae, mueva
de nuevo la palanca del cebador a la
posición 1/2-CHOKE (Cebado medio)
hasta que el motor funcione de manera
suave y, a continuación, mueva la palanca
hasta la posición OPEN (derecha).
NOTA: Si el motor arranca, pero no sigue
funcionando, mueva la palanca del cebador a
la posición Full CHOKE (Cebado completo) a
la izquierda y repita las instrucciones de
arranque.
Apagar el generador
1. Cierre todas las cargas y desconecte
todas las cargas eléctricas de las tomas
de corriente del panel del generador.
2. Deje que el motor funcione sin cargas
durante varios minutos para que se
estabilicen las temperaturas internas del
motor y del generador.
3. Gire el interruptor de ARRANQUE/
MARCHA/PARADA a la posición STOP
(Parada).
4. Gire la válvula de cierre de combustible en
el sentido de las agujas del reloj a la
posición OFF (cerrado).
NOTA: En condiciones normales de uso,
cierre la válvula de combustible y deje que la
cubeta de combustible del generador se
quede sin combustible. En caso de
emergencia, gire el interruptor a la posición
STOP (Parada).
Sistema de cierre por nivel bajo
de aceite
El motor está equipado con un sensor de
presión de aceite baja que apaga el motor
automáticamente cuando el nivel de aceite
cae por debajo de un nivel especificado. El
motor no funcionará hasta que se añada
aceite hasta el nivel adecuado.
Si el motor se apaga y hay combustible
suficiente, compruebe el nivel de aceite del
motor.
(000136)
PRECAUCIÓN
Daños a los equipos y la propiedad. Desconecte las cargas
eléctricas antes de poner en marcha o parar la unidad. No
hacer esto puede provocar daños al equipo y la propiedad.
(000136)
PRECAUCIÓN
Daños a los equipos y la propiedad. Desconecte las cargas
eléctricas antes de poner en marcha o parar la unidad. No
hacer esto puede provocar daños al equipo y la propiedad.
Manual del usuario del generador portátil 17
Sección 4 Mantenimiento y solución de problemas
Mantenimiento
El mantenimiento regular mejorará el
rendimiento y prolongará la vida útil del motor/
equipo. Generac Power Systems, Inc.
recomienda que todo el trabajo de
mantenimiento sea efectuado por un
Concesionario de servicio autorizado
independiente (IASD). El mantenimiento
regular, sustitución o reparación de los
dispositivos y sistemas de control de
emisiones puede ser efectuado por cualquier
taller de reparaciones o mecánico elegido por
el propietario. Sin embargo, para obtener
servicio de garantía gratuito, el trabajo debe
ser efectuado por un Concesionario de
servicio autorizado independiente (IASD). Vea
la garantía de emisiones.
NOTA: Si tiene preguntas acerca de cómo
reemplazar algún componente, llame al
1-888-GENERAC (1-888-436-3722).
Programa de mantenimiento
Consulte los intervalos del programa de
mantenimiento, lo que ocurra primero según
el uso.
NOTA: Las condiciones adversas requerirán
un mantenimiento más frecuente.
NOTA: Vaya a www.generac.com o póngase
en contacto con un servicio técnico autorizado
independiente para solicitar piezas de
repuesto.
NOTA: Todas las operaciones de manteni-
miento y ajustes necesarios deben realizarse
cada temporada, tal y como se detalla en el
siguiente gráfico.
Mantenimiento preventivo
La suciedad o los residuos pueden hacer que
el equipo no funcione de manera correcta y
provocar daños en este. Limpie el generador
a diario o antes de cada uso. Mantenga la
zona alrededor y detrás del silenciador sin
suciedad de combustible. Revise las ranuras
y aberturas del aire de enfriamiento del
generador.
Utilice un paño húmedo para limpiar las
superficies exteriores.
Utilice un cepillo de cerdas suaves para
retirar la suciedad endurecida, el aceite,
etc.
Utilice una aspiradora para eliminar la
suciedad y los residuos sueltos.
Se puede utilizar aire a baja presión (que
no supere los 25 psi) para eliminar la
suciedad. Inspeccione las ranuras del aire
de refrigeración y las aberturas del
generador. Estas aberturas deben
mantenerse limpias y sin obstrucciones.
NOTA: NO utilice una manguera de jardín
para limpiar el generador. El agua podría
entrar en el sistema del combustible del motor
y causar problemas. Si el agua entrara en el
generador a través de las ranuras del aire de
refrigeración, parte de esta agua podría
quedar retenida en huecos y hendiduras del
aislante del bobinado del rotor y del estator.
La acumulación de agua y suciedad en los
bobinados internos podría disminuir la
resistencia del aislante de estos bobinados.
En cada uso
Comprobar el nivel de aceite del motor
Cada 100 horas o en cada estación*
Limpiar la pantalla del supresor de chispas
Cada estación
Comprobar la holgura de la válvula***
Cada 200 horas o en cada estación
Cambio de aceite ‡
Sustituir la bujía
Sustituir el filtro del combustible
Verificar/limpiar el filtro de aire
‡ Cambiar el aceite después de las
25 primeras horas de funcionamiento y,
después, en cada estación.
* Cambiar el aceite y el filtro de aceite cada
mes cuando el generador funcione con
cargas pesadas o bajo altas temperaturas.
** Limpiar el generador con más frecuencia en
condiciones de funcionamiento con
suciedad o polvo. Sustituya las piezas del
filtro de aire si no se pueden limpiar
correctamente.
*** Comprobar la holgura de la válvula y
ajustarla si fuera necesario después de las
50 primeras horas de funcionamiento y,
después, cada 400 horas.
(000142a)
ADVERTENCIA
Lesiones personales. No inserte objetos a través de las ranuras
de enfriamiento de la unidad. El generador puede arrancar en
cualquier momento y provocar la muerte, lesiones graves y
daños en la unidad.
18 Manual del usuario del generador portátil
Mantenimiento del motor
Recomendaciones sobre el aceite
del motor
Para mantener la garantía del producto,el
aceite de motor se debe mantener conforme a
las recomendaciones de este manual. Para su
comodidad, hay disponibles kits de
mantenimiento para usar en este producto
que incluyen aceite de motor, filtro de aceite,
bujía(s), una toalla de taller y embudo. Estos
kits se pueden obtener de un Concesionario
de servicio autorizado independiente (IASD).
.
Comprobación del nivel de aceite
en el motor
El nivel de aceite se debe verificar antes de
cada uso o al menos cada 8 horas de
funcionamiento.
1. Coloque el generador sobre una superficie
plana.
2. Limpie el área alrededor de la boca de
llenado de aceite.
3. Consulte la Figura 4-1. Quite la tapa de
llenado de aceite y limpie la varilla de
medición.
Figura 4-1. Cómo añadir aceite al motor
4. Introduzca la varilla en el cuello de llenado
de aceite. Retire la varilla y compruebe
que el nivel de aceite se encuentra dentro
del rango de funcionamiento seguro.
Consulte la Figura 4-2.
Figura 4-2. Rango de funcionamiento seguro
5. Añada el aceite de motor recomendado
según sea necesario.
6. Vuelva a colocar la tapa de llenado del
aceite y apriétela de manera manual.
NOTA: Algunas unidades cuentan con más de
un lugar por el que se puede añadir el aceite.
En estos casos, solo se necesita utilizar un
punto de llenado de aceite.
Cambiar filtro de aceite y del aceite
del motor
Si el generador se utiliza en lugares con
mucho polvo o suciedad, o en un clima
extremadamente cálido, cambie el aceite con
más frecuencia.
NOTA: ¡No contamine! Preserve los recursos.
Lleve el aceite usado a centros de recogida.
Cambie el aceite cuando el motor esté frío tal
y como se especifica a continuación:
1. Coloque el generador sobre una superficie
plana.
2. Desconecte el cable de la bujía y
colóquelo donde no pueda hacer contacto
con la bujía.
3. Limpie el área alrededor del tapón de
drenaje y de la boca de llenado de aceite.
4. Quite la tapa de la boca de llenado de
aceite.
5. Retire el tapón de la manguera de drenaje
de aceite y drene el aceite completamente
en un recipiente adecuado.
ADVERTENCIA
(000141)
Arranque accidental. Desconecte los cables de las bujías
al trabajar en la unidad. No hacerlo puede ocasionar la
muerte o lesiones graves.
SAE 30
10W-30
5W-30 sintético
Intervalo de temperatura de uso esperada
000399
ADVERTENCIA
Riesgo de quemaduras. Espere a que el motor
se enfríe antes de vaciar el aceite o el
refrigerante. No hacerlo puede ocasionar la
muerte o lesiones graves.
(000139)
000115
003620
ADVERTENCIA
(000141)
Arranque accidental. Desconecte los cables de las bujías
al trabajar en la unidad. No hacerlo puede ocasionar la
muerte o lesiones graves.
ADVERTENCIA
Riesgo de quemaduras. Espere a que el motor
se enfríe antes de vaciar el aceite o el
refrigerante. No hacerlo puede ocasionar la
muerte o lesiones graves.
(000139)
Manual del usuario del generador portátil 19
6. Vuelva a colocar el tapón de la manguera
de drenaje de aceite y apriételo
firmemente.
7. Coloque un recipiente adecuado debajo
del filtro de aceite y gire el filtro en el
sentido contrario al de las agujas del reloj
para quitarlo. Deséchelo siguiendo las
normativas locales vigentes.
8. Recubra la junta del nuevo filtro con aceite
de motor limpio. Gire el filtro en el sentido
de las agujas del reloj hasta que la junta
entre en contacto ligeramente con el
adaptador de filtro. A continuación, apriete
con un giro adicional de 3/4.
9. Vierta lentamente el aceite en la boca de
llenado hasta alcanzar el nivel de aceite
adecuado para el funcionamiento en la
varilla. NO llene en exceso.
10. Coloque nuevamente la tapa y apriétela
bien.
11. Limpie el aceite que pueda haberse
derramado.
12. Deshágase del aceite de acuerdo con las
regulaciones locales.
Filtro de aire
El motor no funcionará correctamente y puede
sufrir daños si se utiliza con un filtro de aire
sucio. Reemplácelo o límpielo más a menudo
si utiliza la unidad bajo condiciones de mucha
suciedad o polvo.
Para realizar limpiar/reemplazar el filtro de
aire:
1. Consulte la Figura 4-3. Retire la cubierta
del filtro de aire (A) y el filtro (B).
2. Con cuidado, golpee el filtro sobre una
superficie sólida. Si está muy sucio,
cámbielo por un filtro nuevo.
3. Limpie la cubierta del filtro de aire antes
de instalarla.
NOTA: Para solicitar un nuevo filtro de aire,
póngase en contacto con el centro de servicio
técnico autorizado independiente más
cercano llamando al 1-888-GENERAC
(1-888-436-3722).
Figura 4-3. Conjunto del filtro de aire
Mantenimiento de la bujía
Para realizar el mantenimiento a la bujía:
1. Limpie la zona que rodea la bujía.
2. Retire e inspeccione la bujía.
3. Compruebe la separación entre electrodos
con un calibrador de alambre y configúrela
a la medida de 0,020 pulg. (0,51 mm).
Consulte la Figura 4-4.
Figura 4-4. Bujía
NOTA: Cambie la bujía si los electrodos están
carbonizados o quemados o si la porcelana
está rota. Reemplace la bujía
EXCLUSIVAMENTE con otra bujía
recomendada. Consulte las especificaciones.
4. Instale la bujía y apriétela manualmente y
gírela 3/8 a 1/2 vuelta utilizando la llave
para bujías.
Sustitución de la batería
(si procede)
NOTA: La batería incluida con el generador
se entrega cargada totalmente. Una batería
puede perder parte de la carga cuando no se
utiliza durante periodos de tiempo
prolongados. Es posible que tenga que cargar
la batería antes de utilizarla por primera vez.
Al poner en funcionamiento el generador, la
batería se cargará.
Consulte la Figura 4-5.
1. Desconecte y retire los tornillos de
montaje de la batería (8 mm) y el cable
NEGRO (B) del borne NEGATIVO (-) de la
batería.
2. Mueva la funda protectora roja (A) y quite
los tornillos de montaje de la batería
(8 mm) y el cable ROJO (C) del borne
POSITIVO (+) de la batería.
3. Instale la nueva batería. Sujete la batería
con la cinta.
4. Conecte el cable ROJO con el borne
POSITIVO (+) de la batería (C). Coloque
la funda de goma (A) en los tornillos de
conexión.
003466
A
B
000211
000211
ADVERTENCIA
Arranque accidental. Desconecte el cable negativo de
la batería, luego el cable positivo de la batería cuando
trabaje en la unidad. No hacerlo puede ocasionar la
muerte o lesiones graves.
(000130)
20 Manual del usuario del generador portátil
5. Conecte el cable NEGRO con el borne
NEGATIVO (-) de la batería (B).
Figura 4-5. Conexión de la batería
Inspección del silenciador y del
dispositivo antichispas
NOTA: Constituye una infracción del artículo
4442 del Código de Recursos Públicos de
California utilizar o hacer funcionar el motor
en la proximidades de terrenos boscosos o de
rastrojos o que estén cubiertos de hierba a
menos que el sistema de escape esté
equipado con un dispositivo antichispas, tal y
como se define en la Sección 4442. Además,
este motor debe mantenerse en un buen
estado de funcionamiento. Otros estados o
jurisdicciones federales pueden aplicar
normas legales similares.
Póngase en contacto con el fabricante original
del equipo, el vendedor o el distribuidor para
obtener un dispositivo antichispas para el
sistema de escape instalado en este motor.
NOTA: Use SOLAMENTE equipo o repuestos
originales.
Inspeccione el silenciador por si tuviese
grietas, corrosión u otros daños. Retire el
dispositivo antichispas, si lo hubiese, y realice
una inspección en busca de daños o bloqueo
por la presencia de carbón. Reemplace las
piezas si ello es necesario.
Inspección del filtro del dispositivo
antichispas
1. Afloje la abrazadera (A). Consulte la
Figura 4-6.
2. Revise el cono (C) y sustitúyalo si está
desgastado, perforado o dañado de
alguna manera. Si el cono no está
dañado, límpielo con un disolvente
comercial.
3. Sustituya el cono del supresor de chispas
(C) y el collar (B). Sujételo con la
abrazadera (A).
Figura 4-6. Pantalla del supresor de chispas
Holgura de la válvula
Importante: Póngase en contacto con un
servicio técnico independiente autorizado
para obtener ayuda. Este es un paso muy
importante para asegurar una larga vida útil
del motor.
Compruebe la holgura de la válvula después
de las 50 primeras horas de funcionamiento.
Ajústela según sea necesario.
Entrada — 0,05 ± 0,08 mm,
(0,002" ± 0,003" pulgadas)
Salida — 0,05 ± 0,08 mm,
(0,002" ± 0,003" pulgadas)
003760
A
C
B
ADVERTENCIA
Peligro ambiental. Siempre recicle las baterías en un
centro de reciclado oficial de acuerdo con todas las leyes
y reglamentos locales. No hacerlo puede ocasionar
daños ambientales, la muerte o lesiones graves.
(000228)
ADVERTENCIA
(000108)
Superficies calientes. Al usar la máquina, no toque las
superficies calientes. Mantenga la máquina alejada
de los combustibles durante el uso. Las superficies
calientes pueden ocasionar quemaduras
graves o incendio.
003467
A
B
C
Manual del usuario del generador portátil 21
Almacenamiento
General
Se recomienda arrancar el generador una vez
cada 30 días, y debería funcionar durante
30 minutos. Si no puede hacerlo, consulte la
siguiente lista para preparar la unidad para su
almacenamiento.
NO coloque una cubierta de
almacenamiento en un generador caliente.
Espere a que el generador se enfríe
completamente antes de almacenarlo.
NO guarde combustible de una temporada
a otra a menos que se trate de un modo
adecuado.
Sustituya el contenedor de combustible si
está oxidado. El óxido en el combustible
puede provocar problemas en el sistema
de combustible.
Cubra la unidad con una cubierta
protectora adecuada, resistente a la
humedad.
Guarde la unidad en un área limpia y seca.
Guarde siempre el generador y el
combustible lejos de fuentes de calor e
ignición.
Preparación del sistema de
combustible para su
almacenamiento
El combustible puede echarse a perder y
dañar los componentes del sistema de
combustible si se almacena durante más de
30 días. Para mantener el combustible en
buen estado, utilice un estabilizante.
Si se añade estabilizador de combustible al
sistema de combustible, prepare y ponga en
marcha el motor para su almacenamiento
durante un largo período. Deje que el motor
funcione durante 10-15 minutos para que el
estabilizador circule por todo el sistema. El
combustible preparado adecuadamente
puede almacenarse hasta 24 meses.
NOTA: Si el combustible no se ha tratado con
un estabilizador de combustible, debe
drenarse en un contenedor aprobado para tal
fin. Deje que el motor funcione hasta que se
detenga por la falta de combustible. Para
mantener el combustible en buen estado, se
recomienda añadir estabilizante de com-
bustible en el recipiente de almacenamiento.
1. Cambie el aceite del motor.
2. Quite la bujía.
3. Vierta una cucharada (5-10cc) de aceite
de motor limpio o pulverice con un agente
protector adecuado en el cilindro.
4. Tire del arranque manual varias veces
para distribuir el aceite en el cilindro.
5. Vuelva a instalar la bujía.
6. Tire lentamente del arranque manual
hasta sentir resistencia. Esto cerrará las
válvulas para que la humedad no pueda
entrar en el cilindro del motor. Suelte
suavemente el arranque manual.
Cambio de aceite
Cambie el aceite del motor antes de
guardarlo. Consulte Cambiar filtro de aceite y
del aceite del motor.
(000143)
PELIGRO
Explosión e incendio. El combustible y los vapores son
extremadamente inflamables y explosivos. Almacene el
combustible en una zona bien ventilada. Mantenga
alejados el fuego y las chispas. No hacerlo ocasionará la
muerte o lesiones graves.
ADVERTENCIA
(000109)
Riesgo de incendio. Verifique que la máquina se
haya enfriado apropiadamente antes de instalar una
cubierta y almacenar la máquina. Las superficies
calientes pueden ocasionar un incendio.
(000181)
Pérdida de la visión. Es obligatorio llevar protección
ocular para evitar las salpicaduras procedentes de la
cavidad de la bujía al girar el motor. De lo contrario,
se puede provocar la pérdida de la visión.
ADVERTENCIA
Manual del usuario del generador portátil 22
Solución de problemas
PROBLEMA CAUSA SOLUCIÓN
El motor funciona,
pero la salida de CA
no está disponible.
1. El disyuntor está ABIERTO.
2. Conexión deficiente o cable
defectuoso.
3. El dispositivo conectado está
averiado.
4. Fallo en el generador.
5. El módulo del disyuntor de
GFCI está ABIERTO.
1. Restablezca el disyuntor.
2. Revise y repare.
3. Conecte otro dispositivo que
esté en buen estado.
4. Póngase en contacto con el
servicio técnico autorizado
independiente.
5. Corrija el fallo del circuito de
tierra y pulse el botón de
reinicio en el módulo de GFCI.
El motor funciona de
manera correcta
sin carga, pero se
detiene cuando se le
agrega carga.
1. Cortocircuito en una carga
conectada.
2. El generador está
sobrecargado.
3. La velocidad del motor es
demasiado lenta.
4. Cortocircuito en el generador.
5. Filtro del combustible sucio.
6. Dispositivo antichispas
bloqueado.
1. Desconecte la carga eléctrica
en cortocircuito.
2. Consulte
Conozca los límites
del generador
.
3. Póngase en contacto con el
servicio técnico autorizado
independiente.
4. Póngase en contacto con el
servicio técnico autorizado
independiente.
5. Sustituya el filtro del
combustible.
6. Limpie la pantalla del supresor
de chispas.
El motor no arranca o
arranca y funciona con
dificultad.
1. La válvula de cierre de
combustible está en posición
OFF (APAGADO).
2. Filtro de aire sucio.
3. Sin combustible.
4. Combustible deteriorado.
5. El cable de la bujía no está
conectado a la bujía.
6. Bujía averiada.
7. Agua en el combustible.
8. Exceso de cebado.
9. Nivel de aceite bajo.
10. Mezcla de combustible
excesivamente rica.
11. Válvula de admisión atascada
en posición abierta o cerrada.
12. El motor perdió compresión.
13. Filtro del combustible sucio.
1. Gire la válvula de cierre de
combustible a la posición ON
(ABIERTA).
2. Limpie o sustituya el filtro de
aire.
3. Llene el depósito de
combustible.
4. Vacíe el depósito de
combustible y llénelo con
combustible nuevo.
5. Conecte el cable a la bujía.
6. Sustituya la bujía.
7. Vacíe el depósito de
combustible y llénelo con
combustible nuevo.
8. Coloque la palanca del
cebador a la posición sin
cebado.
9. Llene el cárter hasta el nivel
correcto.
10. Póngase en contacto con el
servicio técnico autorizado
independiente.
11. Póngase en contacto con el
servicio técnico autorizado
independiente.
12. Póngase en contacto con el
servicio técnico autorizado
independiente.
13. Sustituya el filtro del
combustible.
Manual del usuario del generador portátil 23
El motor se apaga
durante el
funcionamiento.
1. Sin combustible.
2. Nivel de aceite bajo.
3. Fallo en el motor.
1. Llene el depósito de
combustible.
2. Llene el cárter hasta el nivel
correcto.
3. Póngase en contacto con el
servicio técnico autorizado
independiente.
Falta potencia en el
motor.
1. La carga es demasiado alta.
2. Filtro de aire sucio.
3. El motor necesita
mantenimiento.
4. Filtro del combustible sucio.
5. Dispositivo antichispas
bloqueado.
1. Reduzca la carga (consulte
Conozca los límites del
generador
).
2. Limpie o sustituya el filtro de
aire.
3. Póngase en contacto con el
servicio técnico autorizado
independiente.
4. Sustituya el filtro del
combustible.
5. Limpiar la pantalla del
supresor de chispas.
El motor aumenta la
tensión o se atasca.
1. El cebador se ha abierto
demasiado pronto.
2. El carburador funciona con
una mezcla demasiado rica o
demasiado pobre.
1. Coloque el cebador en la
posición intermedia hasta que
el motor funcione
suavemente.
2. Póngase en contacto con el
servicio técnico autorizado
independiente.
PROBLEMA CAUSA SOLUCIÓN
24 Manual del usuario del generador portátil
Notas
Manual del usuario del generador portátil 25
Nº de componente 10000004327
Revisión B 05/14/2018
©2018 Generac Power Systems, Inc.
Reservados todos los derechos
Las especificaciones están sujetas a cambios sin
previo aviso.
No se permite la reproducción en ningún formato sin
el consentimiento previo por escrito de Generac
Power System, Inc.
Generac Power Systems, Inc.
S45 W29290 Hwy. 59
Waukesha, WI 53189
1-888-GENERAC (1-888-436-3722)
www.generac.com/pro
Générateur portatif XC
Manuel du propriétaire
Enregistrez votre produit Generac sur :
WWW.GENERAC.COM
1-888-GENERAC
(1-888-436-3722)
CONSERVEZ CE MANUEL POUR RÉFÉRENCE ULTÉRIEURE
003436
MODÈLE : ________________________
N° DE SÉRIE : _____________________
DATE D’ACHAT : __________________
AVERTISSEMENT
(000209b)
Danger de mort. Ce produit doit être utilisé dans
une application critique de support de vie. Le
non-respect de cet avertissement peut entraîner
la mort ou des blessures graves.
Sommaire
Section 1 Introduction et règles de
sécurité .......................................... 1
Introduction ..................................... 1
Règles de sécurité .......................... 1
Signification des symboles
de sécurité ....................................... 1
Risques associés à l’échappement
et à l’emplacement .......................... 2
Risques électriques ......................... 3
Risques d'incendie .......................... 3
Levage ou suspension du
générateur ....................................... 3
Index des normes ............................ 4
Section 2 Informations générales
et mise en place ............................ 5
Connaître son générateur ............... 6
Émissions ........................................ 6
Fiches de raccordement .................. 7
Horomètre ....................................... 8
Retrait des pièces du colis .............. 9
Assemblage .................................... 9
Raccordement des câbles de
batterie (le cas échéant) ................ 10
Ajout d’huile moteur ...................... 10
Carburant ...................................... 11
Section 3 Fonctionnement ......... 12
Questions relatives au
fonctionnement .............................. 12
Avant de démarrer le moteur ........ 12
Préparation du générateur
à l’utilisation ................................... 12
Mise à la terre du générateur
utilisé comme appareil portatif ...... 12
Connaître les limites de son
générateur .................................... 13
Transport/Inclinaison de
l’appareil ....................................... 14
Démarrage des moteurs
à démarrage manuel ..................... 14
Démarrage des moteurs
à démarrage électrique ................. 15
Arrêt du générateur ....................... 15
Système d’arrêt en cas de
faible pression d’huile ................... 15
Section 4 Maintenance et
dépannage ................................... 16
Entretien ....................................... 16
Calendrier de maintenance ........... 16
Maintenance préventive ................ 16
Maintenance du moteur ................ 17
Remplacement de la batterie
(le cas échéant) ............................ 18
Inspection du silencieux et
du pare-étincelles ......................... 19
Jeu de soupapes .......................... 19
Entreposage ................................. 20
Dépannage ................................... 21
(000393a)
AVERTISSEMENT
CANCER ET EFFET NOCIF SUR
LA REPRODUCTION
www.P65Warnings.ca.gov.
Manuel du propriétaire de générateur portatif 1
Section 1 Introduction et règles de sécurité
Introduction
Merci d’avoir acheté ce produit Generac
Power Systems, Inc. Cet appareil a été conçu
pour offrir des performances élevées pendant
de nombreuses années, sous réserve d’un
bon entretien.
Si vous n’avez pas la certitude d’avoir bien
compris une quelconque partie de ce manuel,
contactez le concessionnaire réparateur
indépendant agréé (CRIA) le plus proche de
chez vous, ou bien le Service client de
Generac au 1-888-GENERAC (1-888-436-
3722) ou sur www.generac.com, qui seront
ravis de vous aider.
Il relève de la responsabilité du propriétaire
d’utiliser et d’entretenir cet équipement de
façon sûre et adéquate. Avant d’utiliser, de
réparer ou d’entreposer ce générateur :
Étudiez avec attention toutes les mises en
garde fournies dans ce manuel et sur les
étiquettes apposées sur l’appareil.
Familiarisez-vous avec l’appareil et avec ce
manuel.
Consultez les instructions relatives aux
procédures d’assemblage dans la
section Assemblage. Respectez stricte-
ment les instructions.
Conservez ces instructions pour référence
ultérieure. Fournissez SYSTÉMATIQUE-
MENT ce manuel à tout individu devant
utiliser l’appareil.
Les informations contenues dans ce manuel
décrivent avec exactitude les produits fabri-
qués au moment de la publication du manuel.
Le fabricant se réserve le droit de procéder à
des mises à jour techniques, à des corrections
et à des révisions des produits à tout moment
et sans préavis.
Règles de sécurité
Le fabricant ne peut pas prévoir toutes les
circonstances possibles susceptibles
d’impliquer un danger. Les avertissements
fournis dans ce manuel, ainsi que sur les
étiquettes et autocollants apposés sur
l’appareil, ne sont pas exhaustifs. Si vous
recourez à une procédure, méthode de travail
ou technique d’exploitation qui n’est pas
spécifiquement recommandée par le
fabricant, assurez-vous qu’elle est sûre pour
autrui et n’entrave pas la sécurité de
fonctionnement du générateur.
Tout au long de ce manuel, ainsi que sur les
étiquettes et autocollants apposés sur
l’appareil, des encadrés DANGER, AVERTIS-
SEMENT, ATTENTION et REMARQUE sont
utilisés pour alerter le personnel d’instructions
d’utilisation spéciales dont le non-respect peut
s’avérer dangereux. Respectez scrupuleuse-
ment ces instructions. La signification des
différentes mentions d’alerte est la suivante :
REMARQUE : Les remarques fournissent des
informations complémentaires importantes sur
une opération ou une procédure. Elles sont
intégrées au texte ordinaire du manuel.
Ces alertes de sécurité ne sauraient à elles
seules éliminer les dangers qu’elles signalent.
Afin d’éviter les accidents, il est fondamental
de faire preuve de bon sens et de respecter
strictement les instructions spéciales dans le
cadre de l’utilisation et de la maintenance de
l’appareil.
Signification des symboles
de sécurité
(000100a)
AVERTISSEMENT
Consultez le manuel. Lisez complètement le manuel
et assurez-vous d’en comprendre le contenu avant
d’utiliser l’appareil. Une mauvaise compréhension du
manuel ou de l’appareil consigne pourrait entraîner
la mort ou des blessures graves.
(000001)
DANGER
Indique une situation dangereuse qui, si elle n’est pas évitée,
entraînera la mort ou des blessures graves.
(000002)
AVERTISSEMENT
Indique une situation dangereuse qui, si elle n’est pas évitée,
pourrait entraîner la mort ou des blessures graves.
MISE EN GARDE
Indique une situation dangereuse qui, si elle n’est pas
évitée, pourrait entraîner des blessures légères ou
moyennement graves.
(000003)
L’utilisation d’une génératrice à l’intérieur PEUT CAUSER LA MORT
EN QUELQUES MINUTES.
L’échappement de la génératrice contient du monoxyde de
carbone. C’est un poison qui est invisible et inodore.
NE JAMAIS utiliser à l’intérieur
d’une maison ou d’un garage,
MÊME SI les portes ou les
fenêtres sont ouvertes.
Utiliser uniquement
À L’EXTÉRIEUR et très loin
des fenêtres, portes et évents.
000657
000657
2 Manuel du propriétaire de générateur portatif
Si vous commencez à vous sentir mal, ou
faible, ou à avoir des vertiges après avoir
fait fonctionné le générateur, sortez
IMMÉDIATEMENT à l’air libre. Consultez
un médecin, car il se peut que vous soyez
victime d’une intoxication au monoxyde de
carbone.
Pour des raisons de sécurité, il est
recommandé de confier la maintenance de
cet équipement à un CRIA. Inspectez
régulièrement le générateur, et si certaines
pièces nécessitent une réparation ou un
remplacement, contactez le CRIA le plus
proche de chez vous.
Risques associés à
l’échappement et à
l’emplacement
DANGER
Asphyxie. Le moteur en marche produit du monoxyde
de carbone, un gaz inodore, incolore et toxique.
Le monoxyde de carbone, s’il n’est pas évité,
entraînera la mort ou des blessures graves.
(000103)
(000179b)
DANGER
Risques d’asphyxie. Le système d'échappement doit être
correctement entretenu. N’apportez aucune modification au
système d'échappement au risque de le rendre dangereux
ou non conforme aux codes et/ou normes applicables au
niveau local. Le non-respect de cette consigne risque
d’entraîner des blessures graves, voire mortelles.
(000104)
DANGER
Décharge électrique. Le contact de l’eau avec une
source d’alimentation, s’il n’est pas évité, entraînera la
mort ou des blessures graves.
(000116)
DANGER
Décharge électrique. Coupez l’alimentation du réseau
public et du générateur avant de connecter les câbles
d’alimentation et les lignes de charge. Le non-respect
de cette consigne entraînera la mort ou des blessures
graves.
Dommages à l’équipement et aux biens. Ne modifiez pas la
construction ni l’installation du générateur et ne bloquez pas
la ventilation. Le non-respect de cette consigne pourrait
endommager le générateur ou le rendre dangereux.
(000146)
AVERTISSEMENT
AVERTISSEMENT
(000178a)
Asphyxie. Toujours utiliser à l’intérieur une alarme
à monoxyde de carbone fonctionnant sur pile,
installée selon les instructions du fabricant.
Sinon, cela pourrait entraîner la mort ou
des blessures graves.
(000250)
Dommages à l’équipement et aux biens. Ne faites pas fonctionner l’appareil
sur des surfaces inégales ou dans des zones où il serait exposé à une
humidité excessive, à de la poussière ou à des vapeurs corrosives. Le
non-respect de cette consigne pourrait entraîner la mort ou des blessures
graves, ainsi que des dommages aux biens et à l’équipement.
AVERTISSEMENT
(000111)
AVERTISSEMENT
Pièces mobiles. Gardez les vêtements, les
cheveux et les accessoires loin des pièces mobiles.
Le non-respect de cette consigne pourrait
entraîner la mort ou des blessures graves.
AVERTISSEMENT
(000108)
Surfaces chaudes. Lorsque vous utilisez l’appareil, ne
touchez pas aux surfaces chaudes. Gardez l’appareil
loin des matériaux combustibles lorsqu’il fonctionne.
Le contact avec des surfaces chaudes pourrait entraîner
des brûlures graves ou un incendie.
(000142a)
AVERTISSEMENT
Risque de blessure. Attention à ne jamais introduire d’objets via les
fentes de refroidissement. Le générateur peut démarrer à tout
moment, et ainsi provoquer des blessures sérieuses, voire
mortelles, et endommager considérablement l’appareil.
AVERTISSEMENT
Risque de blessures. Il faut être parfaitement vigilant
pour utiliser cet appareil et en faire l’entretien. La
fatigue peut nuire à votre capacité à entretenir cet
équipement et pourrait entraîner la mort ou des
blessures graves.
(000215)
AVERTISSEMENT
Blessures et dommages à l’équipement. N’utilisez pas le
générateur en guise de marchepied. Ce geste pourrait
entraîner votre chute, des dommages aux pièces, une
utilisation non sécuritaire de l’équipement, des blessures
graves, voire la mort.
(000216)
000406
DANGER
Asphyxie. Le moteur en marche produit du monoxyde
de carbone, un gaz inodore, incolore et toxique.
Le monoxyde de carbone, s’il n’est pas évité,
entraînera la mort ou des blessures graves.
(000103)
(000179b)
DANGER
Risques d’asphyxie. Le système d'échappement doit être
correctement entretenu. N’apportez aucune modification au
système d'échappement au risque de le rendre dangereux
ou non conforme aux codes et/ou normes applicables au
niveau local. Le non-respect de cette consigne risque
d’entraîner des blessures graves, voire mortelles.
Dommages à l’équipement et aux biens. Ne modifiez pas la
construction ni l’installation du générateur et ne bloquez pas
la ventilation. Le non-respect de cette consigne pourrait
endommager le générateur ou le rendre dangereux.
(000146)
AVERTISSEMENT
Manuel du propriétaire de générateur portatif 3
Si vous commencez à vous sentir mal, ou
affaibli, ou à avoir des vertiges après avoir
fait fonctionner le générateur, sortez
IMMÉDIATEMENT à l’air libre. Consultez
un médecin, car il se peut que vous soyez
victime d’une intoxication au monoxyde de
carbone.
NE faites JAMAIS fonctionner un
générateur à l'intérieur ou dans une zone
partiellement fermée telle qu'un garage.
Utilisez UNIQUEMENT à l'extérieur et loin
des fenêtres, des portes, des évents, des
vides sanitaires et dans une zone une
ventilation adéquate est disponible et qui
n'accumulera pas de gaz d'échappement
mortels.
Le fait d'utiliser un ventilateur ou d'ouvrir
une porte ne permet pas une ventilation
suffisante.
Orientez le silencieux d’échappement à
l’écart des personnes et des bâtiments
occupés.
Risques électriques
Le National Electric Code (NEC) des États-
Unis exige que le châssis et toutes les
pièces conductrices externes du
générateur soient correctement raccordés
à une prise de terre approuvée. Les codes
électriques locaux peuvent également
exiger une mise à la terre appropriée du
générateur. Consultez un électricien local
pour connaître les exigences de mise à la
terre propre à votre région.
Risques d'incendie
N’utilisez en aucun cas le générateur si
vous observez une surchauffe des
appareils électriques qui y sont raccordés,
une perte de la puissance électrique,
l’apparition d’étincelles au niveau du
moteur ou du générateur, ou encore de
flammes ou de fumée lorsque l’équipement
est en fonctionnement.
Conservez en permanence un extincteur à
proximité du générateur.
Laissez un dégagement d'au moins 5 pieds
de tous les côtés du générateur lors de son
fonctionnement pour éviter la surchauffe et
les incendies.
Levage ou suspension
du générateur
AVERTISSEMENT
(000178a)
Asphyxie. Toujours utiliser à l’intérieur une alarme
à monoxyde de carbone fonctionnant sur pile,
installée selon les instructions du fabricant.
Sinon, cela pourrait entraîner la mort ou
des blessures graves.
(000144)
DANGER
Décharge électrique. Tout contact avec des ls nus,
des bornes ou des branchements pendant que le
générateur fonctionne causera la mort ou des
blessures graves.
(000104)
DANGER
Décharge électrique. Le contact de l’eau avec une
source d’alimentation, s’il n’est pas évité, entraînera la
mort ou des blessures graves.
(000145)
DANGER
Décharge électrique. En cas d’accident électrique, COUPEZ
immédiatement l’alimentation. Utilisez des outils non
conducteurs pour libérer la victime du conducteur sous
tension. Administrez-lui les premiers soins et allez chercher
de l’aide médicale. Le non-respect de cette consigne
entraînera la mort ou des blessures graves.
AVERTISSEMENT
Démarrage accidentel. Lorsque vous travaillez sur l’appareil,
débranchez le câble négatif de la batterie, puis le câble positif.
Le non-respect de cette consigne pourrait entraîner la mort
ou des blessures graves.
(000130)
(000105)
DANGER
Explosion et incendie. Le carburant et ses vapeurs sont
extrêmement inflammables et explosifs. Ajoutez du
carburant dans un endroit bien aéré. Gardez l’appareil loin
du feu et des étincelles. Le non-respect de cette consigne
entraînera la mort ou des blessures graves.
(000166b)
DANGER
Risque d’explosion et d’incendie. Ne remplissez jamais le
réservoir de carburant de façon excessive. Laissez un espace
d’un demi-pouce par rapport au haut du réservoir pour assurer
la bonne expansion du carburant. Tout remplissage excessif
risque de provoquer des déversements de carburant, avec
un risque de formation d’incendie ou d’explosion, et
de blessures sérieuses, voire mortelles.
(000174)
DANGER
Risque d’incendie. Laissez les déversements d’essence
sécher complètement avant de démarrer le moteur.
Le non-respect de cette consigne entraînera
la mort ou des blessures graves.
(000142a)
AVERTISSEMENT
Risque de blessure. Attention à ne jamais introduire d’objets via les
fentes de refroidissement. Le générateur peut démarrer à tout
moment, et ainsi provoquer des blessures sérieuses, voire
mortelles, et endommager considérablement l’appareil.
AVERTISSEMENT
Risque de blessure. Le raccordement inadéquat des
câbles, chaînes ou sangles de levage peut provoquer
des blessures graves, voire mortelles, ainsi que des
dégâts matériels.
(000346)
Risque de blessure. L’élévation ou la suspension de l’appareil
sans câbles, chaînes ou sangles capables de supporter une
charge de service nominale de 2 000 lb (907 kg) minimum
peut provoquer des blessures graves, voire mortelles, ainsi
que des dégâts matériels.
(000347)
AVERTISSEMENT
Risque de blessure. N’utilisez jamais le générateur en
suspension. Cela peut provoquer des blessures graves,
voire mortelles, ainsi que des dégâts matériels.
(000348)
AVERTISSEMENT
Manuel du propriétaire de générateur portatif 4
Index des normes
1. National Fire Protection Association (NFPA)
70 : NATIONAL ELECTRIC CODE (NEC)
des États-Unis, consultable sur
www.nfpa.org
2. National Fire Protection Association (NFPA)
5000 : BUILDING CONSTRUCTION AND
SAFETY CODE des États-Unis, consultable
sur www.nfpa.org
3. International Building Code, consultable sur
www.iccsafe.org
4. Agricultural Wiring Handbook,consultable
sur www.rerc.org, ou auprès du Rural
Electricity Resource Council, P.O. Box 309,
Wilmington, OH 45177-0309, États-Unis
5. ASAE EP-364.2, Installation and
Maintenance of Farm Standby Electric
Power, consultable sur www.asabe.org, ou
auprès de l’American Society of Agricultural
& Biological Engineers, 2950 Niles Road,
St. Joseph, MI 49085, États-Unis
6. Safety and Performance of Portable
Generators, ANSI/PGMA G300,
consultable sur pgmaonline.com
7. CSA C22.2 100-14 - Installation et
utilisation des moteurs et générateurs
électriques, conformément aux dispositions
du code canadien de l’électricité
Cette liste n’est pas exhaustive. Pour connaître
les codes et normes locaux applicables,
renseignez-vous auprès des autorités
compétentes.
Risque de blessure. N’utilisez pas le crochet de levage
s’il est visiblement endommagé ou corrodé. Cela peut
provoquer des blessures graves, voire mortelles, ainsi
que des dégâts matériels.
(000349)
AVERTISSEMENT
Risque de blessure. N’utilisez pas le crochet de levage
autrement que conformément aux instructions. Le non-respect
de cette consigne peut provoquer des blessures graves,
voire mortelles, ainsi que des dégâts matériels.
(000350)
AVERTISSEMENT
Risque de blessure. Assurez-vous que toutes les fixations
sont bien serrées avant de soulever l’appareil. Le non-respect
de cette consigne peut provoquer des blessures graves,
voire mortelles, ainsi que des dégâts matériels.
(000351)
AVERTISSEMENT
5 Manuel du propriétaire de générateur portatif
Section 2 Informations générales et mise en place
Figure2-1. Fonctions et commandes
TABLEAU 1. Composants du
générateur
Figure2-2. Étiquette d’identification du produit
003442
003441
003436
22
27
12
20
15
14
26
23
19
14
21
10
16
24
18
25
13
17
28
1 Prise double 120 V CA, 20 A
2 Prise à verrouillage 120/240 V CA, 30 A
3 Disjoncteurs unipolaires (CA)
4 Disjoncteurs bipolaires
5 Prise à verrouillage 120 V CA, 30 A
6 Commande de ralenti
7 Module de détection de défaut de mise à
la terre
8 Disjoncteur du module DDFT
9 Horomètre
10 Levier d’étrangleur
11 Interrupteur Démarrage/Marche/Arrêt
(démarrage électrique) (6,5 kW, interrup-
teur Marche/Arrêt, démarrage à rappel)
12 Bougie
13 Filtre à huile
14 Tuyau de vidange d'huile
15 Bouchon de remplissage d'huile
16 Filtre à air
17 Filtre à carburant
18 Lanceur à rappel
19 Silencieux
20 Pare-étincelles
21 Cosse de mise à la terre
22 Poignées
23 Réservoir de carburant
24 Bouchon d’essence
25 Jauge de carburant
26 Batterie (le cas échéant)
27 Dispositif de levage en acier
28 Bouton de déverrouillage des poignées
003447
Manuel du propriétaire de générateur portatif 6
Figure2-3. Panneau de commande du générateur XC
Connaître son générateur
Vous pouvez vous procurer des exemplaires
de remplacement du manuel du propriétaire
sur www.generac.com.
Émissions
L'Agence américaine de protection de l'envi-
ronnement (EPA) (et le Comité des res-
sources de l'air de la Californie (CARB) pour
les moteurs/équipements certifiés selon les
normes californiennes) exige que ce(t)
moteur/équipement soit conforme aux normes
d'émissions d'échappement et par évapora-
tion. Localisez l'autocollant de conformité des
émissions sur le moteur afin de déterminer les
normes applicables. Pour obtenir des informa-
tions sur la garantie des émissions, veuillez-
vous reporter à la garantie des émissions
incluse. Il est important de respecter les spéci-
fications d'entretien décrites dans le manuel
afin de s'assurer que le moteur reste
conforme aux normes d'émissions applicables
pendant toute sa durée de vie.
003439
4
3
6
11
5
1
9
82
7
(000100a)
AVERTISSEMENT
Consultez le manuel. Lisez complètement le manuel
et assurez-vous d’en comprendre le contenu avant
d’utiliser l’appareil. Une mauvaise compréhension du
manuel ou de l’appareil consigne pourrait entraîner
la mort ou des blessures graves.
TABLEAU 2. Caractéristiques techniques du produit
Caractéristiques techniques des générateurs de 6,5 kW / 8 kW
Puissance nominale pour facteur de puissance 1,0 6,5 kW** / 8 kW**
Puissance de démarrage 8,13 kW** / 10 kW**
Tension CA nominale 120/240
Charge CA nominale (120 V / 240 V)
6,5 kW
8,0 kW
54,2 / 27,1 A**
66,7 / 33,3 A**
Fréquence nominale 60 Hz à 3 600 tr/min
Phase Monophasé
Poids de l’appareil (à sec)
6,5 kW (démarrage à l'aide du lanceur à rappel uniquement)
6,5 kW (démarrage électrique)
8,0 kW (démarrage électrique)
246 lb (111,8 kg)
260 lb (117,9 kg)
** Plage de températures de fonctionnement : -18 °C (0 °F) à 40 °C (104 °F). F). Un fonctionnement à
plus de 25 °C (77 °F) risquerait de réduire la puissance.
** La puissance et l’intensité maximales dépendent de, et sont limitées par, des facteurs tels que la
capacité en BTU, la température ambiante, l’altitude, l’état du moteur, etc. La puissance maximale
diminue d’environ 3,5 % tous les 1 000 pieds (304,8 mètres) au-dessus du niveau de la mer, et
diminue d’environ 1 % tous les 6 °C (10 °F) au-dessus de 16 °C (60 °F) de température ambiante.
7 Manuel du propriétaire de générateur portatif
Fiches de raccordement
Prise double 120 V CA, 20 A
La prise 120 V est protégée contre les
surcharges par un disjoncteur à réarmement par
bouton-poussoir de 20 A. Voir la
Figure 2-4
.
Chaque prise alimente des charges
monophasées 120 V CA, 60 Hz nécessitant un
courant maximum de 2 400 W (2,4 kW) ou 20 A.
Utilisez exclusivement des cordons à 3 fils de
grande qualité, bien isolés, mis à la terre et d’une
tension nominale de 125 V à 20 A.
Figure2-4. Prise double 120 V CA,
20 A
NEMA 5-20R
Prise 120/240 V CA, 30 A
Utilisez une fiche NEMA L14-30 avec cette
prise (tournez pour verrouiller/déverrouiller).
Raccordez un cordon à 4 fils adapté mis à la
terre à la fiche et à la charge souhaitée. Le
cordon doit avoir une tension nominale de
250 VCA à 30 A (ou plus). Voir la Figure 2-5.
Utilisez cette prise pour alimenter des
charges monophasées de 120 VCA., 60 Hz
nécessitant une puissance maximale de
3 600 W (3,6 kW) à 30 A ou des charges
monophasées de 240 VCA, 60 Hz
nécessitant une puissance maximale de
7 200 W (7,2 kW) à 30 A. La prise est
protégée par un disjoncteur à bascule
bipolaire de 30 A.
Figure2-5. Prise 120/240 V CA,
30 A NEMA L14-30R
Prise 120 V CA, 30 A
Utilisez une fiche NEMA L5-30 avec cette
prise (tournez pour verrouiller/déverrouiller).
Raccordez un cordon à 3 fils adapté mis à la
terre à la fiche et à la charge souhaitée. Le
cordon doit avoir une tension nominale de
125 V CA à 30 A (ou plus). Voir la Figure 2-6.
Utilisez cette prise pour alimenter des charges
monophasées de 120 V CA, 60 Hz
nécessitant un courant maximum de 3 600 W
(3,6 kW) à 30 A. La prise 120 V est protégée
contre les surcharges par un disjoncteur à
réarmement par bouton-poussoir de 30 A.
Figure2-6. Prise 120 V CA,
30 A NEMA L5-30
Caractéristiques techniques des moteurs de 6,5 kW / 8 kW
Cylindrée 426 cc
Réf. des bougies 0G0767B
Type de bougies Champion RC12YC ou modèle
équivalent
Écartement des bougies 0,02 po (0,51 mm)
Contenance en essence 32 l (8,5 gal U.S.)
Type d’huile Voir le tableau situé à la section
Ajout d’huile moteur.
Contenance en huile
en changeant le filtre
sans changer le filtre
1 l (1,1 pte)
0,9 l (0,95 pte)
Durée de fonctionnement à charge de 50 % (6,5 kW / 8 kW) 14 heures / 11 heures
* Pour obtenir des pièces de rechange, rendez-vous sur www.generac.com ou contactez un CRIA.
TABLEAU 2. Caractéristiques techniques du produit
000424
000204
000844
Manuel du propriétaire de générateur portatif 8
Horomètre
L’horomètre comptabilise les heures de
fonctionnement afin que l’opérateur sache
quand effectuer les opérations de
maintenance planifiée. Voir la Figure 2-7.
L’écran SVC s’allume une heure avant et
une heure après chaque intervalle de
200 heures, laissant ainsi deux heures
pour procéder à la maintenance.
Lorsque l’horomètre clignote en mode
d’alerte, le message relatif à la maintenance
alterne avec la durée écoulée en heures et en
dixièmes d’heure. Les heures clignotent
quatre fois, puis le message relatif à la
maintenance clignote quatre fois, et ce cycle
se répète jusqu’à la réinitialisation
automatique de l’horomètre.
200 heures - SVC – Changer l’huile, le filtre
à huile, le filtre à air, le filtre à carburant et
la bougie. Nettoyer l’écran du pare-
étincelles. (Toutes les 200 heures)
REMARQUE : L’icône représentant un sablier
clignote lorsque le moteur fonctionne. Cela
signifie que l’horomètre enregistre les heures
de fonctionnement.
Figure2-7. Horomètre
Module de détection de défaut de
mise à la terre
L’appareil est équipé d’un disjoncteur
différentiel de fuite à la terre (DDFT). Ce
dispositif est conforme aux exigences des
codes fédéraux, provinciaux et locaux. Le
module de détection de défaut de mise à la
terre couvre toutes les prises.
En cas de défaut de mise à la terre, le DDFT
se déclenche et coupe le flux d'électricité pour
empêcher de graves blessures.
Le DDFT surveille constamment le flux
d’électricité à l’intérieur d’un circuit. Si le
courant traversant un circuit est différent du
courant de retour, le DDFT coupe
l’alimentation en déclenchant de disjoncteur
principal situé sur le panneau de commande
du générateur.
Un DDFT n’assure AUCUNE protection contre
les surcharges, courts-circuits ou chocs
électriques. Un choc électrique peut survenir
si une personne touche des fils électriques
chargés alors qu’elle se trouve sur une
surface non conductrice, telle qu’un plancher
en bois.
Testez le module DDFT avant chaque
utilisation. Voir la Figure 2-8.
1. Démarrez le générateur.
2. Branchez une lampe témoin à la prise
double. La lampe doit s’allumer.
3. Appuyez sur le bouton TEST du DDFT
pour le déclencher. Le disjoncteur
principal doit se déclencher. Cela est
indiqué par le passage de la poignée de
l’actionneur en position ARRÊT.
4. Le flux d’électricité doit cesser et la lampe
s’éteindre. Si le disjoncteur principal ne se
déclenche pas, c’est que le DDFT ne
fonctionne pas. Il ne faut donc pas utiliser
le générateur. Contactez un CRIA.
5. Pour restaurer le flux d’électricité, placez
la poignée de l’actionneur du disjoncteur
en position MARCHE. La poignée doit
rester verrouillée dans cette position.
Dans le cas contraire, soit le DDFT soit le
disjoncteur principal est défectueux. Il faut
donc le remplacer. Contactez un CRIA.
6. Le DDFT est protégé contre les
surcharges par un disjoncteur de 6,5 kW à
30 A ou de 8 kW à 35 A / 240 V.
7. Le DDFT est équipé de fonctions de
Surveillance auto et de Fin de vue avec
témoins d’état DEL.
Figure2-8. Test du DDFT
Commande de ralenti automatique
(le cas échéant)
Cette fonction optimise les économies de
carburant. Lorsque cet interrupteur est en
position MARCHE, le moteur tourne à une
vitesse régulée rapide normale lorsqu’une
charge électrique est connectée. Si la charge
est retirée, le moteur tourne à vitesse réduite.
Lorsque l’interrupteur est en position ARRÊT,
le moteur tourne en continu à vitesse rapide
normale. Assurez-vous systématiquement
que l’interrupteur en en position ARRÊT
lorsque vous démarrez et arrêtez le moteur.
Voir la Figure 2-8.
0000.0
000205
004285
9 Manuel du propriétaire de générateur portatif
Retrait des pièces du colis
1. Ouvrez complètement le carton en
découpant chaque coin de haut en bas.
2. Retirez les pièces du carton et inspectez-
les avant de procéder à l’assemblage. Le
colis doit contenir les pièces suivantes :
TABLEAU 3. Accessoires
3. Si certaines pièces sont absentes du colis,
contactez le Service client de Generac au
1-888-GENERAC (1-888-436-3722) en
vous munissant du nom du modèle et du
numéro de série de l’appareil.
4. Consignez le nom du modèle, le numéro
de série et la date d’achat sur la page de
garde de ce manuel.
Assemblage
Si vous rencontrez des problèmes lors de
l’assemblage, contactez le Service client de
Generac au 1-888-GENERAC (1-888-436-
3722). Veillez à vous munir du nom du modèle
et du numéro de série.
Pour installer les accessoires, vous aurez
besoin des outils suivants :
Tournevis (1)
Clés de 8 mm (2)
Clés de 13 mm (2)
Voir la Figure 2-9.
Installez le dispositif de levage comme suit :
1. Installez chaque moitié du dispositif de
levage (3) sous le châssis et placez sans
trop les serrer les boulons de 45 mm (7) et
les écrous (11) dans les trous prévus à cet
effet sur le châssis.
2. Placez les boulons de 20 mm (10) et les
écrous (11) dans les trous prévus à cet
effet sur les moitiés du dispositif de
levage.
3. Serrez bien tous les boulons.
4. Alignez chaque couvercle supérieur (8)
avec les trous prévus à cet effet sur le
dispositif de levage inférieur. Insérez le
corps de la borne de raccordement (9) et
fixez-le avec une vis de borne de
raccordement (9).
Figure2-9. Assemblage du dispositif de levage
en acier
REMARQUE : Les roues ne sont pas
destinées à un usage sur route.
Voir la Figure 2-10.
Installez les roues comme suit :
1. Faites glisser l’axe (5) dans les trous
prévus à cet effet sur le châssis du
générateur.
2. Faites glisser la roue (1) et une rondelle de
5/8" (6) sur l’axe.
3. Fixez l’ensemble à l’aide d’une épingle (4).
Renouvelez l’opération de l’autre côté du
générateur.
Installez les pieds comme suit :
1. Alignez le pied (2) avec les trous prévus à
cet effet sur le châssis et fixez-le avec des
boulons de 45 mm (7).
Article Qté
Unité principale 1
Manuel du propriétaire 1
Manuel du moteur 1
Bidon d’huile SAE de 1 pinte 1
Filtre à huile 1
Filtre à air 1
Bougie 1
Clé à bougies 1
Chiffon 1
Couvercles supérieurs (8) 2
Roues (1) 2
Pieds du châssis (2) 2
Dispositif de levage en acier (3) 2
Sachet de pièces de quincaillerie Qté
Épingles (4) 2
Axe (5) 1
Rondelles plates 5/8" (6) 2
Boulons de 45 mm (7) 8
Bornes de raccordement (9) 2
Boulons de 20 mm (10) 2
Écrous (11) 6
(000100a
)
AVERTISSEMENT
Consultez le manuel. Lisez complètement le manuel
et assurez-vous d’en comprendre le contenu avant
d’utiliser l’appareil. Une mauvaise compréhension du
manuel ou de l’appareil consigne pourrait entraîner
la mort ou des blessures graves.
003759
3
11
11
10
7
8
9
9
Manuel du propriétaire de générateur portatif 10
Figure2-10. Assemblage des roues et des pieds
Raccordement des câbles de
batterie (le cas échéant)
L’appareil est expédié avec les câbles de
batterie débranchés.
Pour les brancher, vous aurez besoin de deux
clés polygonales de 8 mm. Voir la Figure 4-5.
1. Coupez les attaches de câble retenant les
câbles de batterie et retirez le couvercle
rouge des bornes de la batterie.
2. Commencez par brancher les câbles
rouges à la borne positive (+) de la
batterie à l’aide du boulon et de l’écrou
fournis.
3. Assurez-vous que les raccords sont bien
fixés et faites glisser la gaine en
caoutchouc par-dessus la borne
positive (+) de la batterie et les fixations.
4. Branchez ensuite les câbles noirs à la
borne négative (-) de la batterie à l’aide
du boulon et de l’écrou fournis. Faites
glisser la gaine en caoutchouc par-
dessus la borne négative (+) de la
batterie et les fixations.
5. Assurez-vous que tous les raccords sont
bien fixés.
REMARQUE : Si la batterie ne parvient pas à
démarrer le moteur, chargez-la à l’aide d’un
chargeur approprié de 12 V ou démarrez
manuellement le générateur et laissez tourner
jusqu’à charge complète.
Ajout d’huile moteur
1. Placez le générateur sur une surface de
niveau.
2. Vérifiez que la zone de remplissage
d’huile est propre.
3. Retirez le bouchon de remplissage d’huile
et essuyez la jauge. Voir la Figure 2-11.
Figure2-11. Retrait de la jauge
4. Ajoutez l’huile moteur recommandée. La
viscosité appropriée de l’huile est
déterminée en fonction du climat.
Consultez le tableau pour sélectionner la
bonne viscosité.
REMARQUE : Utilisez de l’huile à base de
pétrole (fournie) pendant le rodage, puis de
l’huile synthétique par la suite.
003448
2
7
5
6
1
3
4
MISE EN GARDE
Risque de dégâts matériels. Ne raccordez pas
la batterie dans le mauvais sens. L’équipement
pourrait s’endommager.
(000167a)
(000135)
Dommages au moteur. Vériez que le type et la quantité de
l’huile à moteur sont adéquats avant de démarrer le moteur. Le
non-respect de cette consigne pourrait causer des dommages
au moteur.
MISE EN GARDE
000115
11 Manuel du propriétaire de générateur portatif
.
REMARQUE : Certains appareils possèdent
plusieurs orifices de remplissage d’huile. Il
n’est pas nécessaire d’utiliser plus d’un point
de remplissage.
5. Vissez la jauge dans le col de remplissage
d’huile. Contrôlez le niveau d’huile une
fois la jauge bien en place au fond du
réservoir.
6. Voir la Figure 2-12. Retirez la jauge et
vérifiez que le niveau d’huile se situe dans
la plage permettant un fonctionnement
sûr.
Figure2-12. Plage de fonctionnement sûr
7. Placez le bouchon de remplissage d’huile /
la jauge et serrez manuellement.
Carburant
Les spécifications relatives au carburant sont
les suivantes :
Essence propre sans plomb.
Indice d’octane minimum de 87 / 87 AKI
(91 RON).
Teneur en éthanol (essence-alcool)
admissible jusqu’à 10 % (lorsque possible,
un carburant premium sans éthanol est
recommandé).
N’UTILISEZ PAS de carburant E85.
N’UTILISEZ PAS de mélange d’huile et
d’essence.
NE MODIFIEZ PAS le moteur pour le faire
fonctionner avec d’autres carburants.
Stabilisez le niveau de carburant avant
d’entreposer le générateur.
1. Vérifiez que l’appareil est en
position ARRÊT et laissez-le refroidir
pendant au moins deux minutes avant de
faire le plein de carburant.
2. Placez l’appareil de niveau dans une zone
bien ventilée.
3. Nettoyez la zone environnant le bouchon
de carburant et retirez-le lentement.
4. Ajoutez lentement le carburant
recommandé. Ne remplissez pas le
réservoir au-dessus de la lèvre intérieure.
Voir la Figure 2-13.
5. Remettez le bouchon de remplissage
d'huile en place.
Figure2-13. Ajout du carburant recommandé
REMARQUE : Laissez le carburant déversé
hors du réservoir s’évaporer avant de
démarrer l’appareil.
REMARQUE IMPORTANTE : Il est
important d’empêcher la formation de
dépôts de gomme dans les pièces du
circuit de carburant telles que le
carburateur, le tuyau de carburant et le
réservoir durant l'entreposage. Les
carburants à base d’alcool (appelés
essence-alcool, éthanol ou méthanol)
peuvent attirer l’humidité, ce qui entraîne
une séparation et la formation d’acides
durant l’entreposage. Les gaz acides
peuvent endommager le circuit de
carburant d’un moteur entreposé. Afin
d’éviter tout problème de moteur, le circuit
de carburant doit être vidé avant tout
entreposage de plus de 30 jours. Voir la
section Entreposage. N’utilisez jamais de
produits nettoyants pour moteur ou
carburateur dans le réservoir de carburant;
cela risquerait de causer des dommages
permanents.
SAE 30
10W-30
5W-30 synthétique
Plage de température de l’utilisation prévue
°C
°F
000399
003620
(000105)
DANGER
Explosion et incendie. Le carburant et ses vapeurs sont
extrêmement inflammables et explosifs. Ajoutez du
carburant dans un endroit bien aéré. Gardez l’appareil loin
du feu et des étincelles. Le non-respect de cette consigne
entraînera la mort ou des blessures graves.
(000166b)
DANGER
Risque d’explosion et d’incendie. Ne remplissez jamais le
réservoir de carburant de façon excessive. Laissez un espace
d’un demi-pouce par rapport au haut du réservoir pour assurer
la bonne expansion du carburant. Tout remplissage excessif
risque de provoquer des déversements de carburant, avec
un risque de formation d’incendie ou d’explosion, et
de blessures sérieuses, voire mortelles.
000230
A
Manuel du propriétaire de générateur portatif 12
Section 3 Fonctionnement
Questions relatives au
fonctionnement
Si vous avez des questions concernant
l’utilisation et l’entretien de l’équipement,
contactez le Service client de Generac au
1-888-GENERAC (1-888-436-3722).
Avant de démarrer le moteur
1. Vérifiez que le niveau d’huile moteur est
correct.
2. Vérifiez que le niveau de carburant est
correct.
3. Vérifiez que l’appareil est installé de niveau,
en extérieur, dans une zone bien ventilée,
et que l’accès à l’appareil est dégagé.
Préparation du générateur
à l’utilisation
Mise à la terre du générateur
utilisé comme appareil portatif
Le générateur est équipé d’une borne
permettant le raccordement d’un système
d’électrodes de mise à la terre.
L’article 250.34 (A) du NEC ne requiert pas la
connexion du châssis à un système
d’électrodes de mise à la terre lorsque le
générateur alimente uniquement des
équipements raccordés à ses prises par un
système de cordon et fiche.
En revanche, si le générateur alimente un
interrupteur de transfert manuel tripolaire ou
des tableaux de distribution pour assurer une
alimentation temporaire, un système
d’électrodes de mise à la terre doit être
installé et raccordé à la borne d’électrodes de
mise à la terre du générateur. Voir les
articles 250.30, 250.34 et 250.52 du NEC
pour clarification. Voir la Figure 3-1.
Neutre raccordé au châssis
Figure3-1.Mise à la terre du générateur
Exigences spéciales
Passez en revue toutes les réglementations
de fédérales et d'état de l’Occupational Safety
and Health Administration (OSHA), ainsi que
tous les codes et ordonnances applicables à
l’usage prévu du générateur. Des
règlementations supplémentaires sont
applicables si le générateur est utilisé sur un
chantier de construction.
Consultez un électricien qualifié, un
inspecteur en électricité ou l'organisme local
compétent pour connaître les exigences
supplémentaires qui peuvent être propres à
votre région, comme par exemple l'obligation
d'enregistrer le générateur auprès des
services publics locaux.
DANGER
Asphyxie. Le moteur en marche produit du monoxyde
de carbone, un gaz inodore, incolore et toxique.
Le monoxyde de carbone, s’il n’est pas évité,
entraînera la mort ou des blessures graves.
(000103)
(000179b)
DANGER
Risques d’asphyxie. Le système d'échappement doit être
correctement entretenu. N’apportez aucune modification au
système d'échappement au risque de le rendre dangereux
ou non conforme aux codes et/ou normes applicables au
niveau local. Le non-respect de cette consigne risque
d’entraîner des blessures graves, voire mortelles.
(000118a)
AVERTISSEMENT
Risque d’incendie. N’utilisez pas le générateur sans
le pare-étincelles. Le non-respect de cette consigne
pourrait entraîner la mort ou des blessures graves.
AVERTISSEMENT
(000178a)
Asphyxie. Toujours utiliser à l’intérieur une alarme
à monoxyde de carbone fonctionnant sur pile,
installée selon les instructions du fabricant.
Sinon, cela pourrait entraîner la mort ou
des blessures graves.
(000110)
AVERTISSEMENT
Risque d’incendie. Les surfaces chaudes peuvent
enammer des matériaux combustibles, ce qui
pourrait causer un incendie. Un incendie pourrait
entraîner la mort ou des blessures graves.
AVERTISSEMENT
(000108)
Surfaces chaudes. Lorsque vous utilisez l’appareil, ne
touchez pas aux surfaces chaudes. Gardez l’appareil
loin des matériaux combustibles lorsqu’il fonctionne.
Le contact avec des surfaces chaudes pourrait entraîner
des brûlures graves ou un incendie.
(000136)
MISE EN GARDE
Dommages à l’équipement et aux biens. Débranchez les
charges électriques avant de démarrer ou d’arrêter l’appareil.
Le non-respect de cette consigne pourrait causer des
dommages à l’équipement et aux biens.
000227
13 Manuel du propriétaire de générateur portatif
Raccordement du générateur au
réseau électrique d’un bâtiment
Il est recommandé d'utiliser un commutateur
de transfert manuel pour le branchement
direct à un circuit électrique du bâtiment. Le
raccordement d'un générateur portatif à un
circuit électrique de bâtiment doit être effectué
par un électricien qualifié en stricte conformité
avec tous les codes et lois électriques
nationaux et locaux.
Raccordement de charges
électriques
Ne raccordez JAMAIS de charges de 240 V à
des prises de 120 V. Ne raccordez JAMAIS de
charges triphasées au générateur. Ne raccordez
JAMAIS de charges de 50 Hz au générateur.
Laissez le moteur se stabiliser et chauffer
pendant quelques minutes après le démarrage.
Branchez et allumez les charges électriques
monophasées de 120 ou 240 V CA, 60 Hz
souhaitées.
Additionnez les puissances (ou intensités)
nominales respectives de toutes les charges à
connecter simultanément. Le total ne doit pas
être supérieur à (a) la puissance / l’intensité
nominale du générateur ou (b) la capacité
nominale du disjoncteur de la prise
d’alimentation. Voir la section Connaître les
limites de son générateur.
Connaître les limites de
son générateur
Une surcharge peut endommager le générateur
et les appareils électriques connectés à celui-ci.
Pour éviter toute surcharge, respectez les
consignes suivantes :
Additionnez les puissances respectives de
tous les appareils électriques à connecter
simultanément. Ce total ne doit JAMAIS être
supérieur à la puissance nominale du
générateur.
La puissance nominale des ampoules est
indiquée sur celles-ci. La puissance
nominale des outils, appareils et moteurs
est indiquée sur une étiquette ou un
autocollant apposé sur ceux-ci.
Si la puissance d’un outil, appareil ou
moteur n’est pas indiquée, multipliez la
tension par l’intensité pour la déterminer
(tension x intensité = puissance).
Certains moteurs électriques, notamment
ceux à induction, nécessitent environ trois
fois plus de puissance pour démarrer que
pour tourner. Cette saute de puissance ne
dure que quelques secondes au
démarrage du moteur. Assurez-vous de la
disponibilité d’une puissance de démarrage
élevée lors de la sélection des appareils à
connecter au générateur :
1. Déterminez la puissance nécessaire au
démarrage du plus gros moteur.
2. Ajoutez à ce chiffre la puissance
nécessaire au fonctionnement de toutes
les autres charges connectées.
Le Guide de référence de la puissance requise
vous aide à déterminer le nombre d’appareils
que le générateur peut alimenter
simultanément.
REMARQUE : Tous les chiffres fournis sont
approximatifs. Pour connaître la puissance
requise par un appareil, consultez l’étiquette
apposée sur celui-ci.
Tableau 3. Guide de référence de la
puissance requise
Appareil Puissance de
fonctionnement
*Climatiseur (12 000 BTU) 1 700
*Climatiseur (24 000 BTU) 3 800
*Climatiseur (40 000 BTU) 6 000
Chargeur de batterie (20 A) 500
Ponceuse à courroie (3") 1 000
Scie à chaîne 1 200
Scie circulaire (6-1/2") 800 à 1 000
*Sécheuse à linge (électrique) 5 750
*Sécheuse à linge (au gaz) 700
*Laveuse à linge 1 150
Cafetière 1 750
*Compresseur (1 HP) 2 000
*Compresseur (3/4 HP) 1 800
*Compresseur (1/2 HP) 1 400
Fer à friser 700
*Déshumidificateur 650
Ponceuse à disque (9") 1 200
Coupe-bordures 500
Couverture chauffante 400
Cloueuse électrique 1 200
Cuisinière électrique
(par élément)
1 500
Poêle à frire électrique 1 250
*Congélateur 700
*Ventilateur de chaudière
(3/5 HP)
875
Ouvre-porte de garage 500 à 750
Sèche-cheveux 1 200
Perceuse à main 250 à 1 100
Taille-haie 450
Clé à chocs 500
Fer à repasser 1 200
*Pompe à jet 800
Tondeuse à gazon 1 200
Ampoule 100
Four à micro-ondes 700 à 1 000
*Refroidisseur de lait 1 100
Manuel du propriétaire de générateur portatif 14
Transport/Inclinaison de
l’appareil
N’entreposez pas et ne transportez pas
l’appareil incliné à un angle de plus de 15°.
Démarrage des moteurs à
démarrage manuel
1. Avant de démarrer le moteur, débranchez
toutes les charges électriques des prises
de l’appareil.
2. Placez le générateur sur une surface de
niveau.
3. Tournez le robinet d’arrêt de
carburant (A) en sens antihoraire pour le
placer en position ARRÊT (ouverte). Voir
la Figure 3-2.
4. Tounez l’interrupteur de MARCHE/ARRÊT
en position MARCHE. Voir le Tableau 1 :
Composants du générateur.
.
Figure3-2.Commandes du moteur
5. Faites glisser le levier d’étrangleur (B) en
position ÉTRANGLEMENT MAX (gauche).
Voir la Figure 3-2.
6. Voir la Figure 3-2. Saisissez fermement la
poignée du lanceur à rappel (C) et tirez
lentement jusqu’à ressentir une résistance
accrue. Tirez rapidement vers le haut et
vers l’extérieur.
7. Lorsque le moteur démarre, placez le levier
d’étrangleur en position 1/2 ÉTRANGLE-
MENT jusqu’à ce que le moteur tourne sans
à-coups, puis en position complètement
OUVERTE (droite). Si le moteur hésite,
replacez le levier d’étrangleur en position
1/2 ÉTRANGLEMENT jusqu’à ce que le
moteur tourne sans à-coups, puis en
position OUVERTE (droite).
REMARQUE : Si le moteur se lance, mais ne
continue pas à tourner, placez le levier
d’étrangleur en position ÉTRANGLEMENT
MAX (gauche), puis renouvelez la procédure
de démarrage.
REMARQUE IMPORTANTE : Ne surchargez
pas les prises du générateur ou des
panneaux individuels. Ces prises sont
protégées contre les surcharges par des
disjoncteurs à réarmement par bouton-
poussoir. En cas de dépassement de
l’intensité nominale de l’un des
disjoncteurs, celui-ci s’ouvre pour couper
l’alimentation électrique de la prise
associée. Lisez attentivement la section
Connaître les limites de son générateur.
Brûleur à mazout de chaudière 300
Radiateur à mazout
(140 000 BTU)
400
Radiateur à mazout
(85 000 BTU)
225
Radiateur à mazout
(30 000 BTU)
150
*Pistolet à peinture sans air
(1/3 HP)
600
Pistolet à peinture sans air
(portatif)
150
Radio 50 à 200
*Réfrigérateur 700
Mijoteuse 200
*Pompe immergée (1-1/2 HP) 2 800
*Pompe immergée (1 HP) 2 000
*Pompe immergée (1/2 HP) 1 500
*Pompe de vidange 800 à 1 050
*Scie circulaire à table (10") 1 750 à 2 000
Téléviseur 200 à 500
Grille-pain 1 000 à 1 650
Coupe-herbe 500
* Prévoyez 3 fois la puissance indiquée pour le
démarrage de ces appareils.
AVERTISSEMENT
(000183)
Risque lié au lanceur à rappel. Le cordon du lanceur
à rappel pourrait se rétracter de façon inattendue.
Un effet de rebond pourrait entraîner la mort ou des
blessures graves.
(000136)
MISE EN GARDE
Dommages à l’équipement et aux biens. Débranchez les
charges électriques avant de démarrer ou d’arrêter l’appareil.
Le non-respect de cette consigne pourrait causer des
dommages à l’équipement et aux biens.
003449
A
C
ARRÊT
MARCHE
B
FERMÉ
15 Manuel du propriétaire de générateur portatif
Démarrage des moteurs à
démarrage électrique
1. Avant de démarrer le moteur, débranchez
toutes les charges électriques des prises
de l’appareil.
2. Placez le générateur sur une surface de
niveau.
3. Tournez le robinet d’arrêt de carburant (A) en
sens antihoraire pour le placer en position
MARCHE (ouverte). Voir la Figure 3-2.
4. Faites glisser le levier d’étrangleur (B) en
position ÉTRANGLEMENT MAX (gauche).
Voir la Figure 3-2.
5. Tournez et maintenez l’interrupteur
DÉMARRAGE/MARCHE/ARRÊT en posi-
tion DÉMARRAGE. Au démarrage du
moteur, relâchez l’interrupteur en position
MARCHE.
6. Lorsque le moteur démarre, placez le levier
d’étrangleur en position 1/2 ÉTRANGLE-
MENT jusqu’à ce que le moteur tourne
sans à-coups, puis en position complè-
tement OUVERTE (droite). Si le moteur
hésite, replacez le levier d’étrangleur en
position 1/2 ÉTRANGLEMENT jusqu’à ce
que le moteur tourne sans à-coups, puis en
position OUVERTE (droite).
REMARQUE : Si le moteur se lance, mais ne
continue pas à tourner, placez le levier
d’étrangleur en position ÉTRANGLEMENT
MAX (gauche), puis renouvelez la procédure
de démarrage.
Arrêt du générateur
1. Arrêtez toutes les charges et débranchez-
les des prises du panneau du générateur.
2. Laissez le moteur tourner sans charges
pendant quelques minutes pour stabiliser
les températures internes du moteur et du
générateur.
3. Placez l’interrupteur DÉMARRAGE/
MARCHE/ARRÊT en position ARRÊT.
4. Tournez le robinet d’arrêt de carburant en
sens horaire pour le placer en
position MARCHE (fermée).
REMARQUE : En conditions normales,
fermez le robinet de carburant et laissez le
générateur faire tourner la cuve du
carburateur sans carburant. En cas
d’urgence, placez l’interrupteur sur ARRÊT.
Système d’arrêt en cas de faible
pression d’huile
Le moteur est équipé d’un capteur de faible
pression d’huile qui arrête automatiquement le
moteur lorsque la pression d’huile chute
en dessous de la limite spécifiée. Le moteur
ne tournera pas tant que le réservoir d’huile
n’aura pas été rempli à un niveau approprié.
Si le moteur s’arrête alors que la quantité de
carburant est suffisante, contrôlez le niveau
d’huile moteur.
(000136)
MISE EN GARDE
Dommages à l’équipement et aux biens. Débranchez les
charges électriques avant de démarrer ou d’arrêter l’appareil.
Le non-respect de cette consigne pourrait causer des
dommages à l’équipement et aux biens.
(000136)
MISE EN GARDE
Dommages à l’équipement et aux biens. Débranchez les
charges électriques avant de démarrer ou d’arrêter l’appareil.
Le non-respect de cette consigne pourrait causer des
dommages à l’équipement et aux biens.
Manuel du propriétaire de générateur portatif 16
Section 4 Maintenance et dépannage
Entretien
Un entretien régulier permet d'améliorer les
performances et de prolonger la durée de vie
du moteur/de l'équipement. Generac Power
Systems, Inc. préconise que tous les travaux
d'entretien soient menés par un fournisseur de
services d'entretien agréé. Pour l'entretien
régulier, le remplacement ou la réparation des
appareils et des systèmes de contrôle des
émissions, le propriétaire peut faire appel à la
personne ou à l'atelier de réparation de son
choix. Toutefois, pour obtenir un service de
garantie relatif au contrôle des émissions sans
frais, cette tâche doit être confiée à un fournis-
seur de services d'entretien agréé. Consultez
la garantie en matière d'émissions.
REMARQUE : Pour toute question relative au
remplacement des composants, contactez le
Service client de Generac au 1-888-
GENERAC (1-888-436-3722).
Calendrier de maintenance
Respectez les intervalles de maintenance, en
tenant toujours compte de la première
occurrence selon l’utilisation.
REMARQUE : Des conditions difficiles
imposent des opérations de maintenance plus
fréquentes.
REMARQUE : Pour obtenir des pièces de
rechange, rendez-vous sur www.generac.com
ou contactez un CRIA.
REMARQUE : Les différents réglages et
réparations requis doivent être effectués
chaque saison comme détaillé dans le tableau
suivant.
Maintenance préventive
Des saletés ou des débris peuvent provoquer
des dysfonctionnements et endommager
l’équipement. Nettoyez le générateur
quotidiennement ou avant chaque utilisation.
Maintenez la zone environnant le silencieux
libre de tout débris combustible. Inspectez
toutes les fentes de refroidissement du
générateur.
Nettoyez les surfaces externes à l’aide d’un
chiffon humide.
Éliminez la crasse, les résidus d’huile, etc.,
à l’aide d’une brosse douce.
Éliminez les saletés et les débris à l’aide
d’un aspirateur.
Vous pouvez utiliser de l’air à basse
pression (25 psi max.) pour souffler les
saletés. Inspectez toutes les fentes de
refroidissement du générateur. Ces fentes
doivent rester propres et dégagées.
REMARQUE : N’utilisez JAMAIS un boyau
d’arrosage pour nettoyer le générateur. De
l’eau risquerait de pénétrer dans le circuit de
carburant du moteur, provoquant ainsi des
dysfonctionnements. En cas de pénétration
d’eau dans le générateur par les fentes de
refroidissement, une partie de cette eau se
loge dans les creux et crevasses du rotor ainsi
que dans l’isolation des enroulements du
stator. L’accumulation d’eau et de saletés au
niveau des enroulements internes du
générateur peut réduire la résistance
d’isolement des enroulements.
À chaque utilisation
Contrôle du niveau d’huile
Toutes les 100 heures ou chaque saison*
Nettoyage de l’écran du pare-étincelles
Chaque saison
Contrôle du jeu de soupapes***
Toutes les 200 heures ou chaque saison
Remplacement de l’huile Ƅ
Remplacement de la bougie
Remplacement du filtre à carburant
Inspection/Nettoyage du filtre à air**
Ƅ Remplacez l’huile au bout des 25 premières
heures de fonctionnement, puis chaque sai-
son par la suite.
*Remplacez l’huile et le filtre à huile chaque
mois en cas de charge lourde ou de tempé-
ratures élevées.
**Nettoyez le filtre à air plus souvent en cas
d’environnement sale ou poussiéreux. Si
les pièces du filtre à air ne peuvent pas être
nettoyées correctement, remplacez-les.
***Contrôlez le jeu de soupapes et ajustez-le
si nécessaire après les 50 premières
heures de fonctionnement, puis toutes les
400 heures par la suite.
(000142a)
AVERTISSEMENT
Risque de blessure. Attention à ne jamais introduire d’objets via les
fentes de refroidissement. Le générateur peut démarrer à tout
moment, et ainsi provoquer des blessures sérieuses, voire
mortelles, et endommager considérablement l’appareil.
17 Manuel du propriétaire de générateur portatif
Maintenance du moteur
Recommandations relatives à
l'huile moteur
Afin que la garantie du produit reste en
vigueur, l’entretien de l’huile à moteur doit être
fait conformément aux recommandations du
présent manuel. Pour un entretien facile, des
trousses d’entretien conçues pour cet appareil
sont offertes par le fabricant. Elles com-
prennent de l’huile à moteur, un filtre à huile,
un filtre à air, des bougies d’allumage, un chif-
fon et un entonnoir. Ces trousses sont dispo-
nibles auprès d’un fournisseur indépendant de
services d’entretien agréé.
.
Inspection du niveau d’huile moteur
Inspectez le niveau d’huile moteur avant
chaque utilisation ou toutes les 8 heures de
fonctionnement.
1. Placez le générateur sur une surface de
niveau.
2. Nettoyez la zone de remplissage d’huile.
3. Voir la Figure 4-1. Retirez le bouchon de
remplissage d’huile et essuyez la jauge.
Figure 4-1. Plein d’huile moteur
4. Vissez la jauge dans le col de remplissage
d’huile. Retirez la jauge et vérifiez que le
niveau d’huile se situe dans la plage
permettant un fonctionnement sûr. Voir la
Figure 4-2.
Figure 4-2. Plage de fonctionnement sûr
5. Ajoutez la quantité requise d’huile moteur
recommandée.
6. Replacez le bouchon de remplissage
d’huile et serrez-le manuellement.
REMARQUE : Certains appareils possèdent
plusieurs orifices de remplissage d’huile. Il
n’est pas nécessaire d’utiliser plus d’un point
de remplissage.
Remplacement de l'huile moteur et
du filtre à huile
Si vous utilisez le générateur dans un
environnement extrêmement difficile, sale,
poussiéreux ou chaud, remplacez l’huile plus
fréquemment.
REMARQUE : Ne polluez pas. Conservez les
ressources. Jetez l’huile usée dans un centre
de collecte des déchets approprié.
Remplacez l’huile lorsque le moteur est froid,
en procédant comme suit :
1. Placez le générateur sur une surface de
niveau.
2. Débranchez le fil de la bougie et placez-le
à l’écart de celle-ci pour éviter tout
contact.
3. Nettoyez la zone de remplissage d’huile et
le bouchon de vidange d’huile.
4. Retirez le bouchon de remplissage d’huile.
5. Retirez le bouchon du tuyau de vidange
d’huile et purgez la totalité de l’huile dans
un conteneur adapté.
AVERTISSEMENT
(000141)
Démarrage accidentel. Débranchez les câbles de bougie lorsque
vous travaillez sur l’appareil. Le non-respect de cette consigne
pourrait entraîner la mort ou des blessures graves.
SAE 30
10W-30
5W-30 synthétique
Plage de température de l’utilisation prévue
°C
°F
000399
AVERTISSEMENT
Risque de brûlures. Laissez refroidir le moteur avant
de vidanger l’huile ou le liquide de refroidissement.
Le non-respect de cette consigne pourrait entraîner
la mort ou des blessures graves.
(000139)
000115
003620
AVERTISSEMENT
(000141)
Démarrage accidentel. Débranchez les câbles de bougie lorsque
vous travaillez sur l’appareil. Le non-respect de cette consigne
pourrait entraîner la mort ou des blessures graves.
AVERTISSEMENT
Risque de brûlures. Laissez refroidir le moteur avant
de vidanger l’huile ou le liquide de refroidissement.
Le non-respect de cette consigne pourrait entraîner
la mort ou des blessures graves.
(000139)
Manuel du propriétaire de générateur portatif 18
6. Replacez le bouchon du tuyau de vidange
d’huile et serrez-le fermement.
7. Placez un conteneur adapté sous le filtre à
huile et tournez le filtre en sens antihoraire
pour le retirer. Jetez-le conformément aux
réglementations locales.
8. Appliquez un léger revêtement d’huile
moteur propre sur le joint du filtre neuf.
Tournez le filtre en sens horaire jusqu’à ce
que le joint soit juste en contact avec
l’adaptateur. Serrez ensuite le filtre de 3/4
de tour supplémentaires.
9. Versez lentement l’huile dans l’orifice de
remplissage jusqu’à ce que le niveau
d’huile se situe dans la plage de
fonctionnement sûr. NE REMPLISSEZ
PAS LE RÉSERVOIR D’HUILE DE
FAÇON EXCESSIVE.
10. Replacez le bouchon de remplissage
d’huile et serrez-le manuellement.
11. Essuyez toute huile déversée hors du
réservoir.
12. Jetez l’huile conformément à toutes les
réglementations applicables.
Filtre à air
Si le filtre à air est sale, le moteur ne
fonctionne pas correctement et risque d’être
endommagé. Effectuez la maintenance du
filtre à air plus souvent en cas
d’environnement sale ou poussiéreux.
Pour procéder à la maintenance du filtre à air :
1. Voir la Figure 4-3. Retirez le couvercle (A)
du filtre à air et le filtre à air (B).
2. Tapotez délicatement le filtre contre une
surface solide. Si le filtre est trop sale,
remplacez-le.
3. Nettoyez le couvercle du filtre à air avant
de le remettre en place.
REMARQUE : Pour commander un filtre à air
neuf, contactez le CRIA le plus proche de
chez vous ou le Service client de Generac au
1-888-GENERAC (1-888-436-3722).
Figure 4-3. Filtre à air
Entretien de la bougie
Pour effectuer la maintenance de la bougie :
1. Nettoyez soigneusement la zone
environnant la bougie.
2. Retirez et inspectez la bougie.
3. Inspectez l’écartement des électrodes à
l’aide d’une jauge à fils et réajustez-le si
nécessaire à 0,02 po (0,51 mm). Voir la
Figure 4-4.
Figure 4-4. Bougie
REMARQUE : Ne remplacez la bougie que si
les électrodes sont trouées ou brûlées, ou si la
porcelaine est fissurée. Utilisez
EXCLUSIVEMENT la bougie de rechange
recommandée. Voir les Caractéristiques
techniques.
4. Installez la bougie en la serrant
manuellement, puis serrez de 3/8 à 1/2
tour à l’aide d’une clé à bougies.
Remplacement de la batterie
(le cas échéant)
REMARQUE : L’appareil est expédié avec la
batterie complètement chargée. Si elle n'est
pas utilisée pendant une période prolongée,
une batterie peut se décharger partiellement.
Il peut être nécessaire de charger la batterie
avant la première utilisation. Pour ce faire, il
suffit de faire fonctionner le générateur.
Voir la Figure 4-5.
1. Débranchez les fixations (8 mm) et le
fil NOIR (B) de la borne NÉGATIVE (-) de
la batterie.
2. Retirez la gaine en caoutchouc rouge (A)
et débranchez les fixations (8 mm) et le
fil ROUGE (C) de la borne POSITIVE (+)
de la batterie.
3. Installez la batterie neuve. Fixez la batterie
à l’aide de la sangle prévue à cet effet.
4. Raccordez le fil ROUGE à la
borne POSITIVE (+) de la batterie (C).
Faites glisser la gaine en caoutchouc (A)
par-dessus les fixations.
5. Raccordez le fil NOIR à la borne
NÉGATIVE (-) de la batterie (B).
003466
A
B
000211
AVERTISSEMENT
Démarrage accidentel. Lorsque vous travaillez sur l’appareil,
débranchez le câble négatif de la batterie, puis le câble positif.
Le non-respect de cette consigne pourrait entraîner la mort
ou des blessures graves.
(000130)
19 Manuel du propriétaire de générateur portatif
Figure 4-5. Raccordement de la batterie
Inspection du silencieux et
du pare-étincelles
REMARQUE : L’utilisation du moteur sur un
terrain recouvert de forêt, de broussailles ou
d’herbe constitue une violation de
l’Article 4442 du California Public Resource
Code, à moins que le système d’échappement
ne soit équipé d’un pare-étincelles entretenu
en bon état de fonctionnement, comme défini
dans ledit article. Des lois similaires peuvent
s’appliquer dans d’autres juridictions.
Pour vous procurer un pare-étincelles adapté
au système d’évacuation de ce moteur,
contactez le fabricant d’équipement d’origine,
un revendeur ou un concessionnaire.
REMARQUE : Utilisez EXCLUSIVEMENT
des pièces de rechange d’origine.
Inspectez le silencieux pour vérifier l’absence
de fissures, de signes de corrosion ou
d’autres dommages. Retirez le pare-étincelles
(le cas échéant) et inspectez-le pour vérifiez
qu’il n’est pas endommagé, ni obstrué par les
dépôts de calamine. Remplacez les pièces
endommagées.
Inspection de l’écran
du pare-étincelles
1. Desserrez la bride (A). Voir la Figure 4-6.
2. Inspectez le cône (C) et remplacez-le s’il
est tordu, perforé ou autrement
endommagé. Si le cône est en bon état,
nettoyez-le à l’aide d’un solvant
commercial.
3. Remettez le cône (C) et le collier (B) du
pare-étincelles en place. Fixez l’ensemble
avec la bride (A).
Figure 4-6. Écran du pare-étincelles
Jeu de soupapes
IMPORTANT : Contactez un concessionnaire
réparateur indépendant agréé pour obtenir de
l’aide. Si vous souhaitez prolonger la durée de
vie du moteur, il est impératif que le jeu de
soupapes soit correctement réglé.
Contrôlez le jeu de soupapes après les
50 premières heures de fonctionnement.
Ajustez-le si nécessaire.
Admission — 0,05 à 0,08 mm
(0,002 à 0,003 po)
Échappement — 0,05 à 0,08 mm
(0,002 à 0,003 po)
003760
A
C
B
AVERTISSEMENT
Risque environnemental. Recyclez toujours les batteries dans
un centre de recyclage officiel, conformément aux lois et aux
réglementations locales. Le non-respect de cette consigne
pourrait causer des dommages à l’environnement,
la mort ou des blessures graves.
(000228)
AVERTISSEMENT
(000108)
Surfaces chaudes. Lorsque vous utilisez l’appareil, ne
touchez pas aux surfaces chaudes. Gardez l’appareil
loin des matériaux combustibles lorsqu’il fonctionne.
Le contact avec des surfaces chaudes pourrait entraîner
des brûlures graves ou un incendie.
003467
A
B
C
Manuel du propriétaire de générateur portatif 20
Entreposage
Généralités
Il est recommandé de démarrer le générateur
pour le faire tourner pendant 30 minutes tous
les 30 jours. Si cela s’avère impossible,
respectez les consignes suivantes pour
préparer l’appareil à l’entreposage.
Ne placez JAMAIS un couvercle
d’entreposage sur un générateur chaud.
Laissez l’appareil refroidir à température
ambiante avant de l’entreposer.
N’entreposez JAMAIS de carburant d’une
saison à une autre à moins de l’avoir traité
de façon appropriée.
Remplacez le conteneur de carburant s’il
présente des traces de rouille. La présence
de rouille dans le carburant provoque des
dysfonctionnements du circuit de
carburant.
Recouvrez l’appareil d’un couvercle de
protection adapté résistant à l’humidité.
Entreposez l’appareil dans un lieu propre et
sec.
Veillez à toujours entreposer le générateur
et le carburant à l’écart des sources de
chaleur et d’inflammation.
Préparation du circuit de carburant
à l'entreposage
Le carburant entreposé pendant plus de
30 jours peut se dégrader et endommager les
composants du circuit de carburant.
Conservez le carburant frais et utilisez un
stabilisateur de carburant.
Si un stabilisateur a été ajouté au circuit de
carburant, préparez le moteur pour un
entreposage de longue durée. Faites tourner
le moteur pendant 10 à 15 minutes pour faire
circuler le stabilisateur dans l’ensemble du
circuit de carburant. Un carburant préparé de
façon appropriée peut être entreposé pendant
un maximum de 24 mois.
REMARQUE : Si le carburant n’a pas été
traité avec un stabilisateur, il doit être purgé
dans un conteneur adapté. Faites tourner le
moteur jusqu’à ce qu’il s’arrête par manque de
carburant. Il est recommandé d’utiliser un
stabilisateur dans le conteneur d’entreposage
afin de conserver le carburant frais.
1. Remplacez l’huile moteur.
2. Retirez la bougie.
3. Versez une cuillère à table (5-10 cm
3
)
d’huile moteur propre ou vaporisez un
agent anti-buée adapté dans le cylindre.
4. Tirez plusieurs fois la poignée du lanceur à
rappel pour distribuer l’huile dans le
cylindre.
5. Remettez la bougie en place.
6. Tirez lentement la poignée du lanceur à
rappel jusqu’à ressentir une résistance.
Cela a pour effet de fermer les soupapes
afin d’empêcher la pénétration d’humidité
dans le cylindre. Relâchez délicatement la
poignée du lanceur à rappel.
Remplacement de l’huile
Remplacez l’huile moteur avant d’entreposer
le générateur. Voir la section Remplacement
de l'huile moteur et du filtre à huile.
(000143)
DANGER
Explosion et incendie. Le carburant et ses vapeurs sont
extrêmement inflammables et explosifs. Entreposez le
carburant dans un endroit bien aéré. Gardez-le loin du
feu et des étincelles. Le non-respect de cette consigne
entraînera la mort ou des blessures graves.
(000109)
AVERTISSEMENT
Risque d’incendie. Vériez que l’appareil a bien refroidi
avant d’installer une protection de rangement et
d’entreposer l’appareil. Le contact avec des surfaces
chaudes pourrait entraîner un incendie.
AVERTISSEMENT
Perte de la vision. Une protection oculaire est requise
pour éviter les projections provenant du trou de bougie
d’allumage pendant le lancement du moteur. Ne pas
porter de protection oculaire pourrait entraîner
la perte de la vision.
(000181)
Manuel du propriétaire de générateur portatif 21
Dépannage
PROBLÈME CAUSE CORRECTION
Le moteur tourne, mais
aucune sortie CA n’est
disponible.
1. Disjoncteur OUVERT.
2. Mauvais raccordement ou
cordon défectueux.
3. Appareil raccordé défectueux.
4. Défaillance interne au
générateur.
5. Module du disjoncteur DDFT
OUVERT.
1. Réinitialisez le disjoncteur.
2. Contrôlez et réparez.
3. Raccordez un autre appareil
qui est en bon état.
4. Contactez un CRIA.
5. Corrigez le défaut de mise à la
terre et appuyez sur le
bouton Réinitialiser du module
du disjoncteur DDFT.
Le moteur tourne bien
sans charge, mais pas
en présence d’une
charge.
1. Court-circuit dans une charge
connectée.
2. Générateur surchargé.
3. Régime moteur trop lent.
4. Court-circuit interne au
générateur.
5. Filtre à carburant sale.
6. Pare-étincelles bouché.
1. Débranchez la charge élec-
trique court-circuitée.
2. Voir la section
Connaître les
limites de son générateur
.
3. Contactez un CRIA.
4. Contactez un CRIA.
5. Remplacez le filtre à carbu-
rant.
6. Nettoyez l’écran du pare-étin-
celles.
Le moteur ne démarre
pas ou démarre et
tourne mal.
1. Robinet d’arrêt de carburant
en position ARRÊT.
2. Filtre à air sale.
3. Panne de carburant.
4. Carburant éventé.
5. Fil de la bougie non raccordé à
la bougie.
6. Bougie défectueuse.
7. Présence d’eau dans le
carburant.
8. Sur-étranglement.
9. Niveau d’huile faible.
10. Mélange de carburant exces-
sivement riche.
11. Soupape d’admission blo-
quée en position ouverte ou
fermée.
12. Perte de compression du
moteur.
13. Filtre à carburant sale.
1. Tournez le robinet d’arrêt de
carburant en
position MARCHE.
2. Nettoyez ou remplacez le filtre
à air.
3. Remplissez le réservoir de
carburant.
4. Purgez le réservoir de carbu-
rant et faites le plein de carbu-
rant frais.
5. Raccordez le fil à la bougie.
6. Remplacez la bougie.
7. Purgez le réservoir de carbu-
rant et faites le plein de carbu-
rant frais.
8. Placez le levier d’étrangleur en
position ouverte (pas d'étran-
glement).
9. Remplissez le carter au niveau
approprié.
10. Contactez un CRIA.
11. Contactez un CRIA.
12. Contactez un CRIA.
13. Remplacez le filtre à carbu-
rant.
Le moteur s’arrête en
cours de fonctionne-
ment.
1. Panne de carburant.
2. Niveau d’huile faible.
3. Défaillance interne au moteur.
1. Remplissez le réservoir de
carburant.
2. Remplissez le carter au niveau
approprié.
3. Contactez un CRIA.
Manuel du propriétaire de générateur portatif 22
Le moteur manque de
puissance.
1. Charge trop élevée.
2. Filtre à air sale.
3. Maintenance du moteur
requise.
4. Filtre à carburant sale.
5. Pare-étincelles bouché.
1. Réduisez la charge (voir la
section
Connaître les limites
de son générateur
).
2. Nettoyez ou remplacez le filtre
à air.
3. Contactez un CRIA.
4. Remplacez le filtre à carbu-
rant.
5. Nettoyez l’écran du pare-étin-
celles.
Le moteur rencontre des
sautes de régime ou
hésite.
1. L’étranglement s’ouvre trop
tôt.
2. Le carburateur fonctionne
avec un mélange de carburant
trop riche ou trop pauvre.
1. Placez le levier d’étrangleur en
position intermédiaire jusqu’à
ce que le moteur tourne sans
à-coups.
2. Contactez un CRIA.
PROBLÈME CAUSE CORRECTION
23 Manuel du propriétaire de générateur portatif
Remarques
Manuel du propriétaire de générateur portatif 24
Remarques
Manuel du propriétaire de générateur portatif 25
Pièce n° 10000004327 Rév. B 14/05/2018
©2018 Generac Power Systems, Inc.
Tous droits réservés
Les spécifications sont sujettes à modification sans
préavis. Aucune forme de reproduction n’est
autorisée sans le consentement écrit préalable de
Generac Power Systems Inc.
Generac Power Systems, Inc.
S45 W29290 Hwy. 59
Waukesha, WI 53189
1-888-GENERAC (1-888-436-3722)
www.generac.com/pro

Transcripción de documentos

XC Series Portable Generator Owner’s Manual 003436 MODEL:________________________ SERIAL:________________________ DATE PURCHASED:______________ WARNING Loss of life. This product is not intended to be used in a critical life support application. Failure to adhere to this warning could result in death or serious injury. (000209b) Register your Generac product at: WWW.GENERAC.COM 1-888-GENERAC (1-888-436-3722) SAVE THIS MANUAL FOR FUTURE REFERENCE Table of Contents Section 1 Introduction and Safety 1 Introduction ..................................... 1 Safety Rules .................................... 1 Safety Symbols and Meanings ........ 1 Exhaust and Location Hazards ....... 2 Electrical Hazards ........................... 3 Fire Hazards .................................... 3 Lifting or Suspending Generator ..... 3 Standards Index .............................. 4 Section 2 General Information and Setup .............................................. 5 Know Your Generator ..................... 6 Emissions ........................................ 6 Connection Plugs ............................ 7 Hour Meter ...................................... 8 Remove Contents from Carton ....... 8 Assembly ......................................... 9 Battery Cable Connection (if equipped) 10 Add Engine Oil .............................. 10 Fuel ............................................... 11 Section 4 Maintenance and Troubleshooting ..........................16 Maintenance ..................................16 Maintenance Schedule ..................16 Preventive Maintenance ................16 Engine Maintenance ......................16 Battery Replacement (if applicable) 18 Inspect Muffler and Spark Arrester 18 Valve Clearance ............................19 Storage ..........................................19 Troubleshooting .............................20 Section 3 Operation .................... 12 Operation and Use Questions ....... 12 Before Starting Engine .................. 12 Prepare Generator for Use ............ 12 Grounding the Generator When Used as a Portable ................................. 12 Know Generator Limits .................. 13 Transporting/Tipping of the Unit .... 14 Starting Pull Start Engines ............ 14 Starting Electric Start Engines ...... 14 Generator Shut Down ................... 15 Low Oil Pressure Shutdown System . 15 WARNING CANCER AND REPRODUCTIVE HARM www.P65Warnings.ca.gov. (000393a) Section 1 Introduction and Safety Introduction Thank you for purchasing a Generac Power Systems Inc. product. This unit has been designed to provide high-performance, efficient operation, and years of use when maintained properly. WARNING Consult Manual. Read and understand manual completely before using product. Failure to completely understand manual and product could result in death or serious injury. (000100a) If any section of the manual is not understood, contact your nearest Independent Authorized Service Dealer (IASD), or contact Generac Customer Service at 1-888-GENERAC (1888-436-3722), or www.generac.com with any questions or concerns. The owner is responsible for proper maintenance and safe use of the equipment. Before operating, servicing or storing this generator: • Study all warnings in this manual and on the product carefully. • Become familiar with this manual and the unit before use. • Refer to the Assembly section of the manual for instructions on final assembly procedures. Follow the instructions completely. Save these instructions for future reference. ALWAYS supply this manual to any individual that will use this machine. The information in this manual is accurate based on products produced at the time of publication. The manufacturer reserves the right to make technical updates, corrections, and product revisions at any time without notice. Safety Rules The manufacturer cannot anticipate every possible circumstance that might involve a hazard. The alerts in this manual, and on tags and decals affixed to the unit, are not all inclusive. If using a procedure, work method, or operating technique that the manufacturer does not specifically recommend, verify that it is safe for others and does not render the equipment unsafe. Throughout this publication, and on tags and decals affixed to the unit, DANGER, WARNING, CAUTION, and NOTE blocks are used to alert personnel to special instructions about a particular operation that may be hazardous if performed incorrectly or carelessly. Observe them carefully. Alert definitions are as follows: Owner’s Manual for Portable Generator DANGER Indicates a hazardous situation which, if not avoided, will result in death or serious injury. (000001) WARNING Indicates a hazardous situation which, if not avoided, could result in death or serious injury. (000002) CAUTION Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. (000003) NOTE: Notes contain additional information important to a procedure and will be found within the regular text of this manual. These safety alerts cannot eliminate the hazards that they indicate. Common sense and strict compliance with the special instructions while performing the action or service are essential to preventing accidents. Safety Symbols and Meanings DANGER Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell. NEVER use inside a home or garage, EVEN IF doors and windows are open. Only use OUTSIDE and far away from windows, doors, and vents. 000657 DANGER Asphyxiation. Running engines produce carbon monoxide, a colorless, odorless, poisonous gas. Carbon monoxide, if not avoided, will result in death or serious injury. (000103) • If you start to feel sick, dizzy, or weak after the generator has been running, move to fresh air IMMEDIATELY. See a doctor, as you could have carbon monoxide poisoning. DANGER Asphyxiation. The exhaust system must be properly maintained. Do not alter or modify the exhaust system as to render it unsafe or make it noncompliant with local codes and/or standards. Failure to do so will result in death or serious injury. (000179b) 1 DANGER Electrocution. Water contact with a power source, if not avoided, will result in death or serious injury. (000104) DANGER Electrocution. Turn utility and emergency power supplies to OFF before connecting power source and load lines. Failure to do so will result in death or serious injury. (000116) WARNING Equipment and property damage. Do not alter construction of, installation, or block ventilation for generator. Failure to do so could result in unsafe operation or damage to the generator. (000146) 000406 • For safety reasons, it is recommended that the maintenance of this equipment be performed by an IASD. Inspect the generator regularly, and contact the nearest IASD for parts needing repair or replacement. Exhaust and Location Hazards DANGER WARNING Asphyxiation. Always use a battery operated carbon monoxide alarm indoors and installed according to the manufacturer’s instructions. Failure to do so could result in death or serious injury. (000178a) Asphyxiation. Running engines produce carbon monoxide, a colorless, odorless, poisonous gas. Carbon monoxide, if not avoided, will result in death or serious injury. (000103) DANGER WARNING Equipment and property damage. Do not operate unit on uneven surfaces, or areas of excessive moisture, dirt, dust or corrosive vapors. Doing so could result in death, serious injury, property and equipment damage. (000250) WARNING Moving Parts. Keep clothing, hair, and appendages away from moving parts. Failure to do so could result in death or serious injury. (000111) WARNING Hot Surfaces. When operting machine, do not touch hot surfaces. Keep machine away from combustables during use. Hot surfaces could result in severe burns or fire. (000108) WARNING Personal injury. Do not insert any object through the air cooling slots. Generator can start at any time and could result in death, serious injury, and unit damage. (000142a) WARNING Risk of injury. Do not operate or service this machine if not fully alert. Fatigue can impair the ability to service this equipment and could result in death or serious injury. (000215) WARNING Asphyxiation. The exhaust system must be properly maintained. Do not alter or modify the exhaust system as to render it unsafe or make it noncompliant with local codes and/or standards. Failure to do so will result in death or serious injury. (000179b) WARNING Equipment and property damage. Do not alter construction of, installation, or block ventilation for generator. Failure to do so could result in unsafe operation or damage to the generator. (000146) WARNING Asphyxiation. Always use a battery operated carbon monoxide alarm indoors and installed according to the manufacturer’s instructions. Failure to do so could result in death or serious injury. (000178a) • If you start to feel sick, dizzy, or weak after the generator has been running, move to fresh air IMMEDIATELY. See a doctor, as you could have carbon monoxide poisoning. • NEVER run a generator indoors or in a partly enclosed area such as garages. • ONLY use outdoors and far away from windows, doors, vents, crawl spaces and in an area where adequate ventilation is available and will not accumulate deadly exhaust gas. • Using a fan or opening a door will not provide sufficient ventilation. • Point muffler exhaust away from people and occupied buildings. Injury and equipment damage. Do not use generator as a step. Doing so could result in falling, damaged parts, unsafe equipment operation, and could result in death or serious injury. (000216) 2 Owner’s Manual for Portable Generator Electrical Hazards DANGER Electrocution. Contact with bare wires, terminals, and connections while generator is running will result in death or serious injury. (000144) DANGER Electrocution. Water contact with a power source, if not avoided, will result in death or serious injury. (000104) DANGER Electrocution. In the event of electrical accident, immediately shut power OFF. Use non-conductive implements to free victim from live conductor. Apply first aid and get medical help. Failure to do so will result in death or serious injury. (000145) WARNING Accidental Start-up. Disconnect the negative battery cable, then the positive battery cable when working on unit. Failure to do so could result in death or serious injury. (000130) • The National Electric Code (NEC) requires the frame and external electrically conductive parts of the generator be properly connected to an approved earth ground. Local electrical codes may also require proper grounding of the generator. Consult with a local electrician for grounding requirements in the area. Fire Hazards DANGER Explosion and Fire. Fuel and vapors are extremely flammable and explosive. Add fuel in a well ventilated area. Keep fire and spark away. Failure to do so will result in death or serious injury. (000105) DANGER Explosion and Fire. Do not overfill fuel tank. Fill to 1/2 inch from top of tank to allow for fuel expansion. Overfilling may cause fuel to spill onto engine causing fire or explosion, which will result in death or serious injury. (000166b) • Do not operate the generator if connected electrical devices overheat, if electrical output is lost, if engine or generator sparks or if flames or smoke are observed while unit is running. • Keep a fire extinguisher near the generator at all times. • Allow at least 5 feet of clearance on all sides of the generator when operating to prevent overheating and fire. Lifting or Suspending Generator WARNING Personal injury. Failure to properly connect lifting cables, chains, or straps could result in death, serious injury, or property damage. (000346) WARNING Personal injury. Failure to use cables, chains, or straps rated at 2000 lbs. (907 kg) working load or greater to raise or suspend unit could result in death, serious injury, or property damage. (000347) WARNING Personal injury. Never operate generator while suspended. Doing so could result in death, serious injury, or property damage. (000348) WARNING Personal Injury. Do not use lifting hook if there are signs of damage or corrosion. Doing so could result in death, serious injury, or property damage. (000349) WARNING Personal Injury. Do not use lifting hook other than as directed. Failure to do so could result in death, serious injury, or property damage. (000350) WARNING Personal Injury. Verify all fasteners are properly tightened prior to lifting unit. Failure to do so could result in death, serious injury, or property damage. (000351) DANGER Risk of fire. Allow fuel spills to completely dry before starting engine. Failure to do so will result in death or serious injury. (000174) WARNING Personal injury. Do not insert any object through the air cooling slots. Generator can start at any time and could result in death, serious injury, and unit damage. (000142a) Owner’s Manual for Portable Generator 3 Standards Index 1. National Fire Protection Association (NFPA) 70: The NATIONAL ELECTRIC CODE (NEC) available from www.nfpa.org 2. National Fire Protection Association (NFPA) 5000: BUILDING CONSTRUCTION AND SAFETY CODE available from www.nfpa.org 3. International Building Code available from www.iccsafe.org 4. Agricultural Wiring Handbook available from www.rerc.org, Rural Electricity Resource Council P.O. Box 309 Wilmington, OH 45177-0309 5. ASAE EP-364.2 Installation and Maintenance of Farm Standby Electric Power available from www.asabe.org, American Society of Agricultural & Biological Engineers 2950 Niles Road, St. Joseph, MI 49085 6. Safety and Performance of Portable Generators ANSI/PGMA G300 available from pgmaonline.com 7. CSA C22.2 100-14 Electric motors and generators for installation and use, in accordance with the Rules of Canadian Electrical Code. This list is not all inclusive. Check with the Authority Having Jurisdiction (AHJ) for any local codes or standards which may be applicable to your jurisdiction. 4 Owner’s Manual for Portable Generator Section 2 General Information and Setup 27 23 24 25 22 20 14 28 19 26 003436 21 13 12 003441 10 15 17 14 16 18 003442 Figure 2-1. Features and Controls TABLE 1. Generator Components 21 Grounding Lug 1 120 Volt AC, 20 Amp Duplex Receptacle 2 120/240 Volt AC, 30 Amp Locking Receptacle 3 1-pole Circuit Breakers (AC) 24 Gas Cap 4 2-pole Circuit Breaker 25 Fuel Gauge 5 120 Volt AC, 30 Amp Locking Receptacle 26 Battery (if equipped) 6 Idle Control 27 Steel Lifting Pocket 7 Ground Fault Sensing Module 28 Handle Release Knob 8 GFCI Module Circuit Breaker 9 Hour Meter 10 Choke Lever 11 Start/Run/Stop Switch (Electric start) (6.5kW, Run/Stop Switch, recoil start only) 12 Spark Plug 13 Oil Filter 14 Oil Drain 15 Oil Fill 16 Air Filter 17 Fuel Filter 18 Recoil Starter 19 Muffler 20 Spark Arrestor Owner’s Manual for Portable Generator 22 Handles 23 Fuel Tank 003447 Figure 2-2. Unit Identification Label 5 11 6 3 1 9 4 5 2 8 7 003439 Figure 2-3. XC Series Control Panel Know Your Generator Emissions The United States Environmental Protection Agency (US EPA) (and California Air Resources Board (CARB), for engines/equipment certified to California standards) requires that this engine/equipment complies with exhaust and evaporative emissions standards. Locate the emissions compliance decal on the engine to determine applicable standards. For emissions warranty information, please reference the included emissions warranty. It is important to follow the maintenance specifications in the manual to ensure that the engine complies with the applicable emissions standards for the duration of the product’s life. WARNING Consult Manual. Read and understand manual completely before using product. Failure to completely understand manual and product could result in death or serious injury. (000100a) Replacement owner’s manuals are available at www.generac.com. TABLE 2. Product Specifications 6.5 kW / 8.0 kW Generator Specifications Rated Power @ 1.0 Power Factor 6.5kW** / 8.0kW** Starting Watts 8.13kVA** / 10kVA** Rated AC Voltage 120/240 Rated AC Load (120 Volt / 240 Volt) 6.5 kW 8.0 kW 54.2 / 27.1 Amps** 66.7 / 33.3 Amps** Rated Frequency 60 Hz @ 3600 RPM Phase Single Phase Unit Weight (Dry) 6.5 kW (recoil start only) 6.5 kW (electric start) 8.0 kW (electric start) 246 lbs. (111.8 kg) 260 lbs. (117.9 kg) ** Operating Temperature Range: -18 deg. C (0 deg. F) to 40 Deg. C (104 Deg. F). When operated above 25 deg. C (77 deg. F) there may be a decrease in power. ** Maximum wattage and current are subject to, and limited by, such factors as fuel Btu content, ambient temperature, altitude, engine condition, etc. Maximum power decreases about 3.5% for each 1,000 feet above sea level; and will also decrease about 1% for each 6° C (10° F) above 16° C (60° F) ambient temperature. 6 Owner’s Manual for Portable Generator TABLE 2. Product Specifications 6.5 kW / 8.0 kW Engine Specifications Displacement 426 cc Spark Plug Part No. 0G0767B Spark Plug Type Champion RC12YC or Equivalent Spark Plug Gap 0.020 inch (0.51mm) Gasoline Capacity 32 L (8.5 U.S. gallons) Oil Type See chart in Add Engine Oil. Oil Capacity with filter change without filter change 1.0 L (1.1 qt.) 0.9 L (0.95 qt.) Run Time at 50% Load (6.5kW / 8.0kW) 14 Hours / 11 Hours * Go to www.generac.com or contact an IASD for replacement parts. Connection Plugs 120 VAC, 20 Amp, Duplex Receptacle The 120 Volt outlet is overload protected by a 20 Amp push-to-reset circuit breaker. See Figure 2-4. Each receptacle will power 120 Volt AC, single phase, 60 Hz electrical loads requiring up to 2400 watts (2.4 kW) or 20 Amps of current. Use only high quality, wellinsulated, 3-wire grounded cord sets rated for 125 Volts at 20 Amps (or greater). 000204 Figure 2-5. 120/240 VAC, 30 Amp Receptacle NEMA L14-30R 120 VAC, 30 Amp Receptacle 000424 Figure 2-4. 120 VAC, 20 Amp, Duplex Receptacle NEMA 5-20R Use a NEMA L5-30 plug with this receptacle (rotate to lock/unlock). Connect a suitable 3wire cord set to the plug and to desired load. The cord set should be rated for 125 Volts AC at 30 Amps (or greater). See Figure 2-6. Use this receptacle to operate 120 Volt AC, 60Hz, single phase loads requiring up to 3600 watts (3.6kW) of power at 30 Amps. The outlet is protected by a 30 Amp push-to-reset circuit breaker. 120/240 VAC, 30 Amp Receptacle Use a NEMA L14-30 plug with this receptacle (rotate to lock/unlock). Connect a suitable 4wire grounded cord set to plug and desired load. The cord set should be rated 250 Volts AC at 30 Amps (or greater). See Figure 2-5. • Use this receptacle to operate 120 Volt AC, 60 Hz, single phase loads requiring up to 3600 watts (3.6 kW) of power at 30 Amps or 240 Volt AC, 60 Hz, single phase loads requiring up to 7200 watts (7.2 kW) of power at 30 Amps. The outlet is protected by a 2-pole 30 Amp rocker circuit breaker. Owner’s Manual for Portable Generator 000844 Figure 2-6. 120 VAC, 30 Amp Receptacle NEMA L5-30 7 Hour Meter The Hour Meter tracks hours of operation for scheduled maintenance. See Figure 2-7. • The SVC display will illuminate one hour before and one hour after each 200 hour interval providing a two hour window to perform service. When the hour meter is in flash alert mode, the maintenance message will alternate with elapsed time in hours and tenths. The hours will flash four times, then alternate with the maintenance message four times until the meter automatically resets. • 200 hours - SVC — Change oil, oil filter, air filter, fuel filter, and spark plug. Clean spark arrestor screen. (Every 200 hrs) NOTE: The hour glass icon will flash when the engine is running. This signifies the meter is recording hours of operation. 4. This should stop the flow of electricity making the lamp shut off. If the main breaker does not ‘trip’, the GFCI is not working and the generator should not be used. Contact an IASD. 5. To restore the flow of electricity, set the main breaker actuator handle to the ‘ON’ position. The handles should remain latched in this position. If it does not, either the GFCI or the main breaker is failing and should be replaced. Contact an IASD. 6. This GFCI is protected against overload by a 6.5kW, 30 Amp or 8.0kW, 35A/240V main breaker. 7. The GFCI has Auto-Monitor and End-ofLife indications with LED status lights. 0000.0 004285 Figure 2-8. Test the GFCI 000205 Figure 2-7. Hour Meter Ground Fault Sensing Module This unit is equipped with a ground fault circuit interrupter (GFCI). This device meets applicable federal, state and local codes. The ground fault sensing module covers all receptacles. In the event of a ground fault, the GFCI will trip and stop the flow of electricity to prevent serious injury. The GFCI constantly monitors electricity flowing in a circuit. If current flowing through a circuit varies from what is returning, the GFCI switches power off tripping the main circuit breaker on the generator's control panel. A GFCI does NOT protect against circuit overloads, short circuits, or shocks. Electric shock can still occur if a person touches charged electrical wires while standing on a non-conducting surface, such as a wood floor. Test the GFCI module before each use. See Figure 2-8. 1. Start generator. 2. Plug a test lamp into duplex receptacle. The lamp should be on. 3. Press TEST button on GFCI to trip the device. The main breaker should ‘trip’. This is indicated by movement of the actuator handle to the OFF position. 8 Automatic Idle Control (if equipped) This feature improves fuel economy. When this switch is turned ON, the engine will run at a normal fast governed engine speed when electrical load is connected. When load is removed, the engine will run at a reduced speed. With the switch OFF, the engine continually runs at a normal fast engine speed. Always have the switch OFF when starting and stopping the engine. See Figure 2-8. Remove Contents from Carton 1. Open carton completely by cutting each corner from top to bottom. 2. Remove and verify carton contents prior to assembly. Carton contents should contain the following: Owner’s Manual for Portable Generator TABLE 3. Accessories Item Qty. Main Unit 1 Owner’s Manual 1 Engine Manual 1 Quart SAE Oil 1 Oil Filter 1 Air Filter 1 Spark Plug 1 Spark Plug Wrench 1 Shop Towel 1 Top Cover (8) 2 Wheel (1) 2 Frame Foot (2) 2 Steel Lifting Pocket (3) 2 Hardware Bag Qty. See Figure 2-9. Install lifting pocket assembly as follows: 1. Install each halve of lifting pocket (3) underneath frame and loosely assemble with 45mm bolt (7) and nut (11) through holes in frame. 2. Install 20mm bolt (10) and nut (11) through top holes of lifting pocket halves. 3. Tighten all bolts securely. 4. Align each top cover (8) with bottom lifting pocket (3) holes. Insert binding post (9) barrel and secure with binding post screw (9). 7 11 10 9 9 8 3 11 003759 Hair Pin (4) 2 Axle (5) 1 Figure 2-9. Steel Lifting Pocket Assembly 5/8” Flat Washer (6) 2 NOTE: The wheels are not intended for overthe-road use. See Figure 2-10. Install wheels as follows: 1. Slide axle (5) through generator frame axle holes. 2. Slide wheel (1) and one 5/8" flat washer (6) onto axle. 3. Secure with hair pin (4). Repeat on opposite side. Install frame foot assembly as follows: 1. Align frame foot (2) with holes in frame and secure with 45mm bolts (7). 45mm Bolt (7) 8 Binding Post Assembly (9) 2 20mm Bolt (10) 2 Nut (11) 6 3. Call Generac Customer Service at 1-888GENERAC (1-888-436-3722) with the unit model and serial number for any missing carton contents. 4. Record model, serial number, and date of purchase on front cover of this manual. Assembly WARNING Consult Manual. Read and understand manual completely before using product. Failure to completely understand manual and product could result in death or serious injury. (000100a) Call Generac Customer Service at 1-888GENERAC (1-888-436-3722) for any assembly issues or concerns. Please have model and serial number available. The following tools are required to install the accessory kit. • Screwdriver (1) • 8mm Wrench (2) • 13mm Wrench (2) Owner’s Manual for Portable Generator 9 3 5 1 6 2 7 003448 4 Figure 2-10. Wheel and Foot Assembly Battery Cable Connection (if equipped) CAUTION Equipment damage. Do not make battery connections in reverse. Doing so will result in equipment damage. (000167a) The unit has been shipped with the battery cables disconnected. You will need two 8mm box wrenches to connect the battery cables. See Figure 4-5. 1. Cut off cable ties securing battery cables and remove red cover from battery terminal. 2. First, connect the red cables to the positive (+) battery terminal with the bolt and nut supplied. 3. Make sure connections are secure and slide rubber boot over the positive (+) battery terminal and connection hardware. 4. Connect the black cables to the negative (-) battery terminal with the bolt and nut supplied. Slide rubber boot over the negative (-) battery terminal and connection hardware. 5. Make sure all connections are secure. NOTE: If the battery is unable to start the engine, charge it with an appropriate 12V charger or manually start the generator and let run until charged. 10 Add Engine Oil CAUTION Engine damage. Verify proper type and quantity of engine oil prior to starting engine. Failure to do so could result in engine damage. (000135) 1. Place generator on a level surface. 2. Verify oil fill area is clean. 3. Remove oil fill cap and wipe dipstick clean. See Figure 2-11. 000115 Figure 2-11. Remove Dipstick 4. Add recommended engine oil. Climate determines proper engine oil viscosity. See chart to select correct viscosity. NOTE: Use petroleum based oil (supplied) for engine break-in before using synthetic oil. Owner’s Manual for Portable Generator 2. Place unit on level ground in a well ventilated area. 3. Clean area around fuel cap and remove cap slowly. 4. Slowly add recommended fuel. Do not fill above inner lip (A). See Figure 2-13. 5. Install fuel cap. . SAE 30 10W-30 Synthetic 5W-30 A 000399 NOTE: Some units have more than one oil fill location. It is only necessary to use one oil fill point. 5. Thread dipstick into oil filler neck. Oil level is checked with dipstick fully installed. 6. See Figure 2-12. Remove dipstick and verify oil level is within safe operating range. 003620 Figure 2-12. Safe Operating Range 7. Install oil fill cap/dipstick and hand-tighten. Fuel DANGER 000230 Figure 2-13. Add Recommended Fuel NOTE: Allow spilled fuel to evaporate before starting unit. IMPORTANT NOTE: It is important to prevent gum deposits from forming in fuel system parts such as the carburetor, fuel hose or tank during storage. Alcoholblended fuels (called gasohol, ethanol or methanol) can attract moisture, which leads to separation and formation of acids during storage. Acidic gas can damage the fuel system of an engine while in storage. To avoid engine problems, the fuel system should be emptied before storage of 30 days or longer. See the Storage section. Never use engine or carburetor cleaner products in the fuel tank as permanent damage may occur. Explosion and Fire. Fuel and vapors are extremely flammable and explosive. Add fuel in a well ventilated area. Keep fire and spark away. Failure to do so will result in death or serious injury. (000105) DANGER Explosion and Fire. Do not overfill fuel tank. Fill to 1/2 inch from top of tank to allow for fuel expansion. Overfilling may cause fuel to spill onto engine causing fire or explosion, which will result in death or serious injury. (000166b) Fuel requirements are as follows: • Clean, fresh, unleaded gasoline. • Minimum rating of 87 octane/87 AKI (91 RON). • Up to 10% ethanol (gasohol) is acceptable (where available; non-ethanol-premium fuel is recommended). • DO NOT use E85. • DO NOT use a gas oil mix. • DO NOT modify engine to run on alternate fuels. Stabilize fuel prior to storage. 1. Verify unit is OFF and cooled for a minimum of two minutes prior to fueling. Owner’s Manual for Portable Generator 11 Section 3 Operation Operation and Use Questions Call Generac Customer Service at 1-888GENERAC (1-888-436-3722) with questions or concerns about equipment operation and maintenance. Before Starting Engine 1. Verify engine oil level is correct. 2. Verify fuel level is correct. 3. Verify unit is secure on level ground, with proper clearance and is outdoors in a well ventilated area. Prepare Generator for Use DANGER Asphyxiation. Running engines produce carbon monoxide, a colorless, odorless, poisonous gas. Carbon monoxide, if not avoided, will result in death or serious injury. (000103) Grounding the Generator When Used as a Portable The generator is equipped with a terminal for the connection of a grounding electrode system. Article 250.34 (A) does not require the frame of the generator to be connected to a grounding electrode system when the generator only supplies power to cord and plug connected equipment through the receptacles on the generator. When the generator supplies power to a 3pole manual transfer switch or distribution panel boards for temporary power, a grounding electrode system shall be installed and connected to the grounding electrode terminal on the generator. See NEC 250.30, 250.34 and 250.52 for clarification. See Figure 3-1. • Neutral Bonded to Frame DANGER Asphyxiation. The exhaust system must be properly maintained. Do not alter or modify the exhaust system as to render it unsafe or make it noncompliant with local codes and/or standards. Failure to do so will result in death or serious injury. (000179b) WARNING Risk of fire. Do not use generator without spark arrestor installed. Failure to do so could result in death or serious injury. (000118a) WARNING Asphyxiation. Always use a battery operated carbon monoxide alarm indoors and installed according to the manufacturer’s instructions. Failure to do so could result in death or serious injury. (000178a) WARNING Risk of Fire. Hot surfaces could ignite combustibles, resulting in fire. Fire could result in death or serious injury. (000110) WARNING Hot Surfaces. When operating machine, do not touch hot surfaces. Keep machine away from combustibles during use. Hot surfaces could result in severe burns or fire. (000108) CAUTION Equipment and property damage. Disconnect electrical loads prior to starting or stopping unit. Failure to do so could result in equipment and property damage. (000136) 12 000227 Figure 3-1.Grounding the Generator Special Requirements Review all Federal and State Occupational Safety and Health Administration (OSHA) regulations, local codes, and ordinances applicable to the intended use of the generator. Additional regulations may apply if the generator is used at a construction site. Consult a qualified electrician, electrical inspector, or the local agency having jurisdiction for additional requirements that may be unique to your area, such as whether the generator is required to be registered with local utility. Connecting the Generator to a Building Electrical System It is recommended to use a manual transfer switch when connecting directly to a building electrical system. Connecting a portable generator to a building electrical system must be made in strict compliance with all national and local electrical codes and laws, and be completed by a qualified electrician. Owner’s Manual for Portable Generator Connecting Electrical Loads DO NOT connect 240 Volt loads to 120 Volt receptacles. DO NOT connect 3-phase loads to generator. DO NOT connect 50 Hz loads to generator. Let engine stabilize and warm up for a few minutes after starting. Plug in and turn on the desired 120 or 240 Volt AC, single phase, 60 Hz electrical loads. Add up the rated watts (or amps) of all loads to be connected at one time. This total should not be greater than (a) the rated wattage/ amperage capacity of the generator or (b) circuit breaker rating of the receptacle supplying the power. See Know Generator Limits. Know Generator Limits Overloading a generator can result in damage to the generator and connected electrical devices. Observe the following to prevent overload: • Add up the total wattage of all electrical devices to be connected at one time. This total should NOT be greater than the generator's wattage capacity. • The rated wattage of lights can be taken from light bulbs. The rated wattage of tools, appliances, and motors can be found on a data label or decal affixed to the device. • If the appliance, tool, or motor does not give wattage, multiply volts times ampere rating to determine watts (volts x amps = watts). • Some electric motors, such as induction types, require about three times more watts of power for starting than for running. This surge of power lasts only a few seconds when starting such motors. Make sure to allow for high starting wattage when selecting electrical devices to connect to the generator: 1. Figure the watts needed to start the largest motor. 2. Add to that figure the running watts of all other connected loads. The Wattage Reference Guide is provided to assist in determining how many items the generator can operate at one time. NOTE: All figures are approximate. See data label on appliance for wattage requirements. Table 3. Wattage Reference Guide Device *Air Conditioner (12,000 Btu) 1700 *Air Conditioner (24,000 Btu) 3800 *Air Conditioner (40,000 Btu) 6000 Battery Charger (20 Amp) 500 Belt Sander (3") 1000 Chain Saw Circular Saw (6-1/2") *Clothes Dryer (Electric) 1200 800 to 1000 5750 *Clothes Dryer (Gas) 700 *Clothes Washer 1150 Coffee Maker 1750 *Compressor (1 HP) 2000 *Compressor (3/4 HP) 1800 *Compressor (1/2 HP) 1400 Curling Iron 700 *Dehumidifier 650 Disc Sander (9") 1200 Edge Trimmer 500 Electric Blanket 400 Electric Nail Gun 1200 Electric Range (per element) 1500 Electric Skillet 1250 *Freezer 700 *Furnace Fan (3/5 HP) 875 *Garage Door Opener 500 to 750 Hair Dryer 1200 Hand Drill 250 to 1100 Hedge Trimmer 450 Impact Wrench 500 Iron 1200 *Jet Pump 800 Lawn Mower 1200 Light Bulb Microwave Oven Owner’s Manual for Portable Generator Running Watts 100 700 to 1000 *Milk Cooler 1100 Oil Burner on Furnace 300 Oil Fired Space Heater (140,000 Btu) 400 Oil Fired Space Heater (85,000 Btu) 225 Oil Fired Space Heater (30,000 Btu) 150 *Paint Sprayer, Airless (1/3 HP) 600 Paint Sprayer, Airless (hand-held) 150 13 Radio 50 to 200 *Refrigerator 700 Slow Cooker 200 *Submersible Pump (1-1/2 HP) 2800 *Submersible Pump (1 HP) 2000 *Submersible Pump (1/2 HP) 1500 *Sump Pump 800 to 1050 *Table Saw (10") 1750 to 2000 Television 200 to 500 Toaster 1000 to 1650 Weed Trimmer 500 * Allow 3 times the listed watts for starting these devices. Transporting/Tipping of the Unit Do not store or transport the unit at an angle greater than 15 degrees. Starting Pull Start Engines Recoil Hazard. Recoil could retract unexpectedly. Kickback could result in death or serious injury. (000183) CAUTION Equipment and property damage. Disconnect electrical loads prior to starting or stopping unit. Failure to do so could result in equipment and property damage. (000136) 1. Unplug all electrical loads from the unit's receptacles before starting engine. 2. Place generator on a level surface. 3. Rotate the fuel shut-off valve (A) counterclockwise to the ON (open) position. See Figure 3-2. 4. Turn engine STOP/RUN switch to RUN. See Table 1: Generator Components. ON Starting Electric Start Engines CAUTION WARNING CLOSED 6. See Figure 3-2. Firmly grasp recoil handle (C) and pull slowly until increased resistance is felt. Pull rapidly up and away. 7. When engine starts, move choke lever to 1/2 CHOKE position until engine runs smoothly, then fully into OPEN (right) position. If engine falters, move choke lever back to 1/2-CHOKE position until engine runs smoothly, then to OPEN (right) position. NOTE: If engine fires, but does not continue to run, move choke lever to Full CHOKE (left) and repeat starting instructions. IMPORTANT NOTE: Do not overload generator or individual panel receptacles. These outlets are overload protected with pushto-reset circuit breakers. If amperage rating of any circuit breaker is exceeded, that breaker opens and electrical output to that receptacle is lost. Read Know Generator Limits carefully. Equipment and property damage. Disconnect electrical loads prior to starting or stopping unit. Failure to do so could result in equipment and property damage. (000136) 1. Unplug all electrical loads from the unit's receptacles before starting the engine. 2. Place generator on a level surface. 3. Rotate the fuel shut-off valve (A) counterclockwise to the ON (open) position. See Figure 3-2. 4. Slide engine choke lever (B) to Full CHOKE position (left). See Figure 3-2. 5. Turn and hold START/RUN/STOP switch in the START position. When engine starts, release the switch to the RUN position. 6. When engine starts, move choke lever to 1/2 CHOKE position until engine runs smoothly, then fully into OPEN (right) position. If engine falters, move choke lever back to 1/2-CHOKE position until engine runs smoothly, then to OPEN (right) position. NOTE: If engine fires, but does not continue to run, move choke lever to Full CHOKE (left) and repeat starting instructions. OFF 003449 B C A . Figure 3-2.Engine Controls 5. Slide engine choke lever (B) to Full CHOKE position (left). See Figure 3-2. 14 Owner’s Manual for Portable Generator Generator Shut Down CAUTION Equipment and property damage. Disconnect electrical loads prior to starting or stopping unit. Failure to do so could result in equipment and property damage. (000136) 1. Shut off all loads and unplug electrical loads from generator panel receptacles. 2. Let engine run at no-load for several minutes to stabilize internal temperatures of engine and generator. 3. Move START/RUN/STOP switch to STOP. 4. Rotate fuel shut-off valve clockwise to the OFF (closed) position. NOTE: Under normal conditions, close fuel valve and allow generator to run carburetor bowl out of fuel. For emergencies, switch to STOP. Low Oil Pressure Shutdown System The engine is equipped with a low oil pressure sensor that shuts down the engine automatically when the oil pressure drops below specifications. The engine will not run until the oil has been filled to the proper level. If the engine shuts down and there is sufficient fuel, check engine oil level. Owner’s Manual for Portable Generator 15 Section 4 Maintenance and Troubleshooting Maintenance Preventive Maintenance Regular maintenance will improve performance and extend engine/equipment life. Generac Power Systems, Inc. recommends that all maintenance work be performed by an Independent Authorized Service Dealer (IASD). Regular maintenance, replacement, or repair of the emissions control devices and systems may be performed by any repair shop or person of the owner’s choosing. To obtain emissions control warranty service free of charge, the work must be performed by an IASD. See the emissions warranty. NOTE: Call 1-888-GENERAC (1-888-4363722) with questions about component replacement. Dirt or debris can cause improper operation and equipment damage. Clean generator daily or before each use. Keep area around and behind muffler free from combustible debris. Inspect all cooling air openings on generator. Maintenance Schedule Follow maintenance schedule intervals, whichever occurs first according to use. NOTE: Adverse conditions will require more frequent service. NOTE: Go to Generac.com or contact an IASD for replacement parts. NOTE: All required service and adjustments should be each season as detailed in the following chart. At Each Use Check engine oil level Every 100 Hours or Every Season* Clean spark arrestor screen Every Season Check valve clearance*** Every 200 Hours or Every Season Change oil ǂ WARNING Personal injury. Do not insert any object through the air cooling slots. Generator can start at any time and could result in death, serious injury, and unit damage. (000142a) • Use a damp cloth to wipe exterior surfaces clean. • Use a soft bristle brush to loosen caked on dirt, oil, etc. • Use a vacuum to pick up loose dirt and debris. • Low pressure air (not to exceed 25 psi) may be used to blow away dirt. Inspect cooling air slots and openings on generator. These openings must be kept clean and unobstructed. NOTE: DO NOT use a garden hose to clean generator. Water can enter engine fuel system and cause problems. If water enters generator through cooling air slots, some water will be retained in voids and crevices of rotor and stator winding insulation. Water and dirt buildup on generator internal windings will decrease insulation resistance of windings. Engine Maintenance WARNING Accidental start-up. Disconnect spark plug wires when working on unit. Failure to do so could result in death or serious injury. (000141) Replace spark plug Replace fuel filter Inspect/clean air cleaner filter** ǂ Change oil after first 25 hours of operation, then every season. * Change oil and oil filter every month when operating under heavy load or in high temperatures. ** Clean more often under dirty or dusty operating conditions. Replace air filter parts if they cannot be adequately cleaned. *** Check valve clearance and adjust if necessary after first 50 hours of operation and every 400 hours thereafter. 16 Engine Oil Recommendations To maintain the product warranty, the engine oil should be serviced in accordance with the recommendations of this manual. For your convenience, maintenance kits designed and intended for use on this product are available from the manufacturer that include engine oil, oil filter, air filter, spark plug(s), a shop towel and funnel. These kits can be obtained from an Independent Authorized Service Dealer (IASD). Owner’s Manual for Portable Generator Change Engine Oil and Oil Filter SAE 30 WARNING Accidental start-up. Disconnect spark plug wires when working on unit. Failure to do so could result in death or serious injury. (000141) 10W-30 Synthetic 5W-30 WARNING 000399 . Inspect Engine Oil Level WARNING Risk of burns. Allow engine to cool before draining oil or coolant. Failure to do so could result in death or serious injury. (000139) Inspect engine oil level prior to each use, or every 8 hours of operation. 1. Place generator on a level surface. 2. Clean area around oil fill. 3. See Figure 4-1. Remove oil fill cap and wipe dipstick clean. 000115 Figure 4-1. Engine Oil Fill 4. Screw dipstick into filler neck. Remove dipstick and verify oil level is within safe operating range. See Figure 4-2. Risk of burns. Allow engine to cool before draining oil or coolant. Failure to do so could result in death or serious injury. (000139) When using generator under extreme, dirty, dusty conditions, or in extremely hot weather, change oil more frequently. NOTE: Don’t pollute. Conserve resources. Return used oil to collection centers. Change oil while engine cool as follows: 1. Place generator on a level surface. 2. Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug. 3. Clean area around oil fill, and oil drain plug. 4. Remove oil fill cap. 5. Remove oil drain hose cap and drain oil completely into a suitable container. 6. Install oil drain hose cap and tighten securely. 7. Place a suitable container beneath the oil filter and turn filter counterclockwise to remove. Discard according to local regulations. 8. Coat gasket of new filter with clean engine oil. Turn filter clockwise until gasket contacts lightly with filter adapter. Then tighten an additional 3/4 turn. 9. Slowly pour oil into oil fill opening until oil level is in safe operating range on dipstick. DO NOT overfill. 10. Install oil fill cap, and finger tighten. 11. Wipe up any spilled oil. 12. Properly dispose of oil in accordance with all applicable regulations. Air Filter 003620 Figure 4-2. Safe Operating Range 5. Add recommended engine oil as necessary. 6. Replace oil fill cap and hand-tighten. NOTE: Some units have more than one oil fill location. It is only necessary to use one oil fill point. Owner’s Manual for Portable Generator Engine will not run properly and may be damaged if run with a dirty air filter. Service air filter more frequently in dirty or dusty conditions. To service air filter: 1. See Figure 4-3. Remove air filter cover (A) and filter (B). 2. Gently tap filter on a solid surface. If too dirty, replace with new filter. 3. Clean air filter cover before installation. NOTE: To order a new air filter, contact the nearest IASD at 1-888-GENERAC (1-888436-3722). 17 B A 003466 2. Remove the red rubber boot (A) and disconnect the battery connecting hardware (8mm) and RED wire (C) from the battery’s POSITIVE (+) terminal. 3. Install new battery. Secure battery with strap. 4. Connect RED wire to the POSITIVE (+) battery terminal (C). Slide rubber boot (A) over connection hardware. 5. Connect BLACK wire to the NEGATIVE (-) battery terminal (B). Figure 4-3. Air Filter Assembly A Service Spark Plug To service spark plug: 1. Clean area around spark plug. 2. Remove and inspect spark plug. 3. Inspect electrode gap with wire feeler gauge and reset spark plug gap to 0.020 in (0.51 mm). See Figure 4-4. B C 003760 Figure 4-5. Battery Connection WARNING Environmental Hazard. Always recycle batteries at an official recycling center in accordance with all local laws and regulations. Failure to do so could result in environmental damage, death or serious injury. (000228) 000211 Figure 4-4. Spark Plug NOTE: Replace spark plug if electrodes are pitted, burned or porcelain is cracked. Use ONLY recommended replacement plug. See Specifications. 4. Install spark plug finger tight, and tighten an additional 3/8 to 1/2 turn using spark plug wrench. Battery Replacement (if applicable) NOTE: The battery shipped with the generator has been fully charged. A battery may lose some charge when not in use for prolonged periods of time. The battery may have to be charged before the first use. Running the generator will charge battery. WARNING Accidental Start-up. Disconnect the negative battery cable, then the positive battery cable when working on unit. Failure to do so could result in death or serious injury. (000130) Inspect Muffler and Spark Arrester NOTE: It is a violation of California Public Resource Code, Section 4442, to use or operate the engine on any forest-covered, brushcovered, or grass-covered land unless the exhaust system is equipped with a spark arrester, as defined in Section 4442, maintained in effective working order. Other states or federal jurisdictions may have similar laws. Contact original equipment manufacturer, retailer, or dealer to obtain a spark arrester designed for exhaust system installed on this engine. NOTE: Use ONLY original equipment replacement parts. Inspect muffler for cracks, corrosion, or other damage. Remove spark arrester, if equipped, inspect for damage or carbon blockage. Replace parts as required. See Figure 4-5. 1. Disconnect and remove the battery connecting hardware (8mm) and BLACK wire (B) from the battery’s NEGATIVE (-) terminal. 18 Owner’s Manual for Portable Generator Inspect Spark Arrester Screen WARNING Hot Surfaces. When operating machine, do not touch hot surfaces. Keep machine away from combustibles during use. Hot surfaces could result in severe burns or fire. (000108) 1. Loosen clamp (A). See Figure 4-6. 2. Inspect cone (C) and replace if torn, perforated or otherwise damaged. If cone is not damaged, clean with commercial solvent. 3. Replace spark arrestor cone (C) and collar (B). Secure with clamp (A). B C A 003467 Figure 4-6. Spark Arrestor Screen Valve Clearance Important: Please contact an Independent Authorized Service Dealer for service assistance. Proper valve clearance is essential for prolonging the life of the engine. Check valve clearance after the first fifty-hours of operation. Adjust as necessary. • Intake — 0.05 to 0.08 mm (0.002" to 0.003" inch) • Exhaust — 0.05 to 0.08 mm (0.002" to 0.003" inch) Storage General • DO NOT store fuel from one season to another unless properly treated. • Replace fuel container if rust is present. Rust in fuel will cause fuel system problems. • Cover unit with a suitable protective, moisture resistant cover. • Store unit in a clean and dry area. • Always store generator and fuel away from heat and ignition sources. Prepare Fuel System for Storage Fuel stored over 30 days can go bad and damage fuel system components. Keep fuel fresh, use fuel stabilizer. If fuel stabilizer is added to fuel system, prepare and run engine for long term storage. Run engine for 10-15 minutes to circulate stabilizer throughout fuel system. Adequately prepared fuel can be stored up to 24 months. NOTE: If fuel has not been treated with fuel stabilizer, it must be drained into an approved container. Run engine until it stops from lack of fuel. Use of fuel stabilizer in fuel storage container is recommended to keep fuel fresh. 1. Change engine oil. 2. Remove spark plug. 3. Pour tablespoon (5-10cc) of clean engine oil or spray a suitable fogging agent into cylinder. WARNING Vision Loss. Eye protection is required to avoid spray from spark plug hole when cranking engine. Failure to do so could result in vision loss. (000181) 4. Pull starter recoil several times to distribute oil in cylinder. 5. Install spark plug. 6. Pull recoil slowly until resistance is felt. This will close valves so moisture cannot enter engine cylinder. Gently release recoil. Change Oil DANGER Explosion and Fire. Fuel and vapors are extremely flammable and explosive. Store fuel in a well ventilated area. Keep fire and spark away. Failure to do so will result in death or serious injury. Change engine oil before storage. See Change Engine Oil and Oil Filter. (000143) WARNING Risk of Fire. Verify machine has properly cooled before installing cover and storing machine. Hot surfaces could result in fire. (000109) It is recommended to start and run the generator for 30 minutes, every 30 days. If this is not possible, refer to the following list to prepare unit for storage. • DO NOT place a storage cover on a hot generator. Allow unit to cool to room temperature before storage. Owner’s Manual for Portable Generator 19 Troubleshooting PROBLEM CAUSE CORRECTION Engine is running, but AC output is not available. 1. Circuit breaker OPEN. 2. Poor connection or defective cord set. 3. Connected device is bad. 4. Fault in generator. 5. GFCI breaker module is OPEN. 1. Reset circuit breaker. 2. Check and repair. 3. Connect another device that is in good condition. 4. Contact IASD. 5. Correct ground fault and press reset button on GFCI breaker module. Engine runs well at no-load, but bogs when load is applied. 1. Short circuit in a connected load. 2. Generator is overloaded. 3. Engine speed is too slow. 4. Shorted generator circuit. 5. Dirty fuel filter. 6. Clogged spark arrestor. 1. Disconnect shorted electrical load. 2. See Know Generator Limits. 3. Contact IASD. 4. Contact IASD. 5. Replace fuel filter. 6. Clean spark arrestor screen. Engine will not start; or starts and runs rough. 1. 2. 3. 4. 5. Fuel shut-off is OFF. Dirty air filter. Out of fuel. Stale fuel. Spark plug wire not connected to spark plug. 6. Bad spark plug. 7. Water in fuel. 8. Overchoking. 9. Low oil level. 10. Excessive rich fuel mixture. 11. Intake valve stuck open or closed. 12. Engine lost compression. 13. Dirty fuel filter. 1. 2. 3. 4. Engine shuts down during operation. 1. Out of fuel. 2. Low oil level. 3. Fault in engine. 1. Fill fuel tank. 2. Fill crankcase to correct level. 3. Contact IASD. Engine lacks power. 1. 2. 3. 4. 5. 1. Reduce load (see Know Generator Limits). 2. Clean or replace air filter. 3. Contact IASD. 4. Replace fuel filter. 5. Clean spark arrestor screen. Engine surges or stumbles. 1. Choke is opened too soon. 2. Carburetor is running too rich or too lean. 20 Load is too high. Dirty air filter. Engine needs to be serviced. Dirty fuel filter. Clogged spark arrestor. Turn fuel shut-off ON. Clean or replace air filter. Fill fuel tank. Drain fuel tank and fill with fresh fuel. 5. Connect wire to spark plug. 6. Replace spark plug. 7. Drain fuel tank; fill with fresh fuel. 8. Set choke to no choke position. 9. Fill crankcase to correct level. 10. Contact IASD. 11. Contact IASD. 12. Contact IASD. 13. Replace fuel filter. 1. Set choke to halfway position until engine runs smoothly. 2. Contact IASD. Owner’s Manual for Portable Generator Part No. 10000004327 Rev. B 05/14/2018 ©2018 Generac Power Systems, Inc. All rights reserved Specifications are subject to change without notice. No reproduction allowed in any form without prior written consent from Generac Power Systems, Inc. Generac Power Systems, Inc. S45 W29290 Hwy. 59 Waukesha, WI 53189 1-888-GENERAC (1-888-436-3722) www.generac.com/pro Generador portátil serie XC Manual del usuario 003436 MODELO: __________________________ SERIE: ____________________________ FECHA DE LA COMPRA: _____________ ADVERTENCIA Fallecimiento. Este producto no se ha diseñado para que se utilice en aplicaciones de apoyo vital crítico. En caso de hacerlo, podría provocar la muerte o lesiones graves. (000209b) Registre su producto Generac en: WWW.GENERAC.COM 1-888-GENERAC (1-888-436-3722) GUARDE ESTE MANUAL PARA PODER CONSULTARLO EN EL FUTURO Índice de contenidos Sección 1 Introducción y seguridad ....................................... 1 Introducción ..................................... 1 Normas de seguridad ...................... 1 Símbolos de seguridad y significados ..................................... 1 Peligros derivados de las emisiones de escape y la ubicación ................. 2 Peligros eléctricos ........................... 3 Peligros de incendio ........................ 3 Levantar o colgar el generador ....... 3 Índice de normas ............................. 4 Sección 2 Información general y configuración ............................. 5 Conozca su generador .................... 6 Emisiones ........................................ 6 Enchufes de conexión ..................... 7 Contador de horas .......................... 8 Sacar el contenido de la caja .......... 9 Montaje ........................................... 9 Conexión del cable de la batería (si se incluye) ................................ 10 Añadir aceite de motor .................. 10 Combustible .................................. 11 Sección 3 Funcionamiento ......... 13 Preguntas sobre uso y funcionamiento .............................. 13 Antes de arrancar el motor ............ 13 Preparación del generador para su uso ................................... 13 Conexión a tierra del generador cuando se utiliza como aparato portátil ........................................... 13 Conozca los límites del generador ..................................... 14 Transporte o inclinación de la unidad ....................................... 15 Arranque de motores con el tirador de arranque ....................... 15 Arranque de motores con arranque eléctrico ......................... 16 Apagar el generador ..................... 16 Sistema de cierre por nivel bajo de aceite ............................... 16 Sección 4 Mantenimiento y solución de problemas ............... 17 Mantenimiento .............................. 17 Programa de mantenimiento ........ 17 Mantenimiento preventivo ............. 17 Mantenimiento del motor .............. 18 Sustitución de la batería (si procede) ................................... 19 Inspección del silenciador y del dispositivo antichispas ............ 20 Holgura de la válvula .................... 20 Almacenamiento ........................... 21 Solución de problemas ................. 22 Notas ............................................ 24 ADVERTENCIA PRODUCE CÁNCER Y DAÑOS REPRODUCTIVOS www.P65Warnings.ca.gov. (000393a) Sección 1 Introducción y seguridad Introducción Gracias por haber adquirido un producto de Generac Power Systems Inc. Esta unidad se ha diseñado para proporcionar un funcionamiento eficiente, de alto rendimiento y con una vida útil larga si se conserva adecuadamente. ADVERTENCIA Consulte el manual. Lea y comprenda completamente el manual antes de usar el producto. No comprender completamente el manual puede provocar la muerte o lesiones graves. (000100a) Si no entendiera alguno de los apartados de este manual, póngase en contacto con el servicio técnico independiente autorizado más cercano, o con el servicio de atención al cliente de Generac llamando al 1-888GENERAC (1-888-436-3722), o visitando www.generac.com para plantear cualquier pregunta o duda que tenga. El propietario es responsable del mantenimiento adecuado y del uso seguro del equipo. Antes de poner en funcionamiento, revisar o guardar el generador: • Revise atentamente todas las advertencias que aparecen en este manual y en el producto. • Familiarícese con este manual y con la unidad antes de utilizarla. • Consulte la sección Montaje del manual para obtener instrucciones sobre los procedimientos de montaje final. Siga estrictamente las instrucciones. Guarde estas instrucciones para consultarlas en el futuro. Entregue SIEMPRE este manual a cualquier persona que utilice la máquina. La información que aparece en este manual es precisa y está basada en productos fabricados en el momento en el que se editó esta publicación. El fabricante se reserva el derecho de hacer las actualizaciones técnicas, las correcciones y las revisiones de los productos que considere necesarias sin previo aviso. Normas de seguridad El fabricante no puede prever todas las posibles circunstancias que pueden suponer un peligro. Las alertas que aparecen en este manual, y en las etiquetas y los adhesivos pegados en la unidad no incluyen todos los peligros. Si se utiliza un procedimiento, método de trabajo o técnica de funcionamiento no recomendados específicamente por el fabricante, compruebe que sean seguros para otros usuarios y que no pongan en peligro el equipo. Manual del usuario del generador portátil En esta publicación y en las etiquetas y adhesivos pegados en la unidad, los bloques PELIGRO, ADVERTENCIA, PRECAUCIÓN y NOTA se utilizan para alertar al personal sobre instrucciones especiales relacionadas con un funcionamiento que puede ser peligroso si se realiza de manera incorrecta o imprudente. Léalos atentamente y respete sus instrucciones. Las definiciones de alertas son las siguientes: PELIGRO Indica una situación peligrosa que, si no se evita, ocasionará la muerte o lesiones graves. (000001) ADVERTENCIA Indica una situación peligrosa que, si no se evita, podría ocasionar la muerte o lesiones graves. (000002) PRECAUCIÓN Indica una situación de riesgo que, si no se evita, puede producir lesiones leves o moderadas. (000003) NOTA: Las notas incluyen información adicional importante para un procedimiento y se incluyen en el texto normal de este manual. Estos avisos de seguridad no pueden eliminar los peligros que indican. Para evitar accidentes, es importante el sentido común y el seguimiento estricto de las instrucciones especiales cuando se realice la acción o la operación de mantenimiento. Símbolos de seguridad y significados ¡PELIGRO! Usar un generador en interiores LO PUEDE MATAR EN MINUTOS. Los gases de escape del generador contienen monóxido de carbono. Este es un veneno que no se puede ver u oler. NUNCA lo use dentro de una casa o garaje, AUN si la puerta y las ventanas se encuentran abiertas. Úselo únicamente en EXTERIORES, y alejado de ventanas, puertas y ventilaciones. 000657 000657 1 ADVERTENCIA PELIGRO Asfixia. Los motores funcionando producen monóxido de carbono, un gas incoloro, inodoro, y venenoso. El monóxido de carbono, si no se evita, ocasionará la muerte o lesiones graves. (000103) • Si empieza a sentirse enfermo, mareado o débil después de que el generador haya estado funcionando, salga INMEDIATAMENTE para respirar aire fresco. Visite un médico ya que podría haberse intoxicado con monóxido de carbono. PELIGRO Asfixia. El sistema de escape debe mantenerse adecuadamente. No altere ni modifique el sistema de escape ya que podría hacer que su funcionamiento sea inseguro o que no cumpla con los códigos y/o normativas locales. En caso de no hacerlo, podría provocarse la muerte o lesiones graves. (000179b) Lesiones personales. No inserte objetos a través de las ranuras de enfriamiento de la unidad. El generador puede arrancar en cualquier momento y provocar la muerte, lesiones graves y daños en la unidad. (000142a) ADVERTENCIA Riesgo de lesión. No opere ni proporcione servicio a esta máquina si no está completamente alerta. La fatiga puede desvirtuar la capacidad para proporcionar servicio a este equipo y puede ocasionar la muerte o lesiones graves. (000215) ADVERTENCIA Lesiones o daños al equipo. No use el generador como un escalón. Hacerlo puede ocasionar caídas, piezas dañadas, funcionamiento inseguro del equipo, la muerte o lesiones graves. (000216) PELIGRO Electrocución. Si no se evita el contacto del agua con una fuente de alimentación, ocasionará la muerte o lesiones graves. (000104) PELIGRO Electrocución. APAGUE el suministro de alimentación de emergencia y de la red eléctrica antes de conectar la fuente de alimentación y las líneas de carga. En caso de no hacerlo, podría provocar la (000116) muerte o lesiones graves. ADVERTENCIA Daños a los equipos y la propiedad. No altere la construcción, instalación, o bloquee la ventilación para el generador. No hacer esto puede provocar el funcionamiento inseguro o dañar el generador. (000146) ADVERTENCIA Asfixia. En interiores, utilice siempre una alarma de monóxido de carbono alimentada por pilas e instalada de acuerdo con las instrucciones de los fabricantes. En caso de no hacerlo, podría provocarse (000178a) la muerte o lesiones graves. 000406 • Por razones de seguridad, se recomienda que el mantenimiento de este equipo sea efectuado por un distribuidor autorizado independiente. Revise el generador regularmente y póngase en contacto con el servicio técnico autorizado independiente más cercano para reparar o sustituir los componentes que sea necesario. Peligros derivados de las emisiones de escape y la ubicación PELIGRO ADVERTENCIA Daños a los equipos y a la propiedad. No use la unidad sobre superficies desniveladas, o en zonas con exceso de humedad, suciedad, polvo, o vapores corrosivos. Hacerlo puede ocasionar la muerte, lesiones graves y daños al equipo. (000250) Asfixia. Los motores funcionando producen monóxido de carbono, un gas incoloro, inodoro, y venenoso. El monóxido de carbono, si no se evita, ocasionará la muerte o lesiones graves. (000103) PELIGRO ADVERTENCIA Piezas en movimiento. Mantenga la ropa, cabello, y extremidades alejados de las piezas en movimiento. No hacerlo puede ocasionar la muerte o lesiones graves. Asfixia. El sistema de escape debe mantenerse adecuadamente. No altere ni modifique el sistema de escape ya que podría hacer que su funcionamiento sea inseguro o que no cumpla con los códigos y/o normativas locales. En caso de no hacerlo, podría provocarse la muerte o lesiones graves. (000179b) (000111) ADVERTENCIA ADVERTENCIA Superficies calientes. Al usar la máquina, no toque las superficies calientes. Mantenga la máquina alejada de los combustibles durante el uso. Las superficies calientes pueden ocasionar quemaduras (000108) graves o incendio. 2 Daños a los equipos y la propiedad. No altere la construcción, instalación, o bloquee la ventilación para el generador. No hacer esto puede provocar el funcionamiento inseguro o dañar el generador. (000146) Manual del usuario del generador portátil Peligros de incendio ADVERTENCIA Asfixia. En interiores, utilice siempre una alarma de monóxido de carbono alimentada por pilas e instalada de acuerdo con las instrucciones de los fabricantes. En caso de no hacerlo, podría provocarse (000178a) la muerte o lesiones graves. • Si empieza a sentirse enfermo, mareado o débil después de que el generador haya estado funcionando, salga INMEDIATAMENTE para respirar aire fresco. Consulte con un médico ya que podría haberse intoxicado con monóxido de carbono. • No ponga NUNCA en marcha el generador en interiores o en áreas parcialmente cerradas como, por ejemplo, garajes. • Use SOLAMENTE el generador en áreas exteriores y lejos de ventanas, puertas, ventilaciones, espacios de rastreo y en áreas en las que no haya una ventilación adecuada y se puedan acumular gases de escape mortales. • Usar un ventilador o abrir una puerta no proporciona la suficiente ventilación. • Coloque el sistema de escape del silenciador lejos de la gente y de los edificios habitados. Peligros eléctricos PELIGRO Electrocución. El contacto con cables, terminales y conexiones peladas mientras el generador está funcionando provocará la muerte o lesiones graves. (000144) PELIGRO Electrocución. Si no se evita el contacto del agua con una fuente de alimentación, ocasionará la muerte o lesiones graves. (000104) PELIGRO Explosión e incendio. El combustible y los vapores son extremadamente inflamables y explosivos. Añada combustible en una zona bien ventilada. Mantenga alejados el fuego y las chispas. No hacerlo puede ocasionar la muerte o lesiones graves. (000105) PELIGRO Explosión e incendio. No sobrepase el nivel del depósito de combustible. Llene el depósito y deje sin llenar media pulgada de la parte superior del mismo para que quede espacio para la expansión del mismo. Si lo llena en exceso puede hacer que el combustible se derrame en el motor provocando un incendio o explosión, lo cual podría provocar la muerte o lesiones graves. (000166b) PELIGRO Riesgo de incendio. Deje que los derrames de combustible se sequen completamente antes de poner en marcha el motor. No hacerlo ocasionará la muerte o lesiones graves. (000174) ADVERTENCIA Lesiones personales. No inserte objetos a través de las ranuras de enfriamiento de la unidad. El generador puede arrancar en cualquier momento y provocar la muerte, lesiones graves y daños en la unidad. (000142a) • No utilice el generador si los dispositivos eléctricos conectados se sobrecalientan, si se pierde la potencia eléctrica, si el motor o el generador producen chispas o si se detectan llamas o humo mientras la unidad está funcionando. • Tenga un extintor cerca del generador en todo momento. • Deje una distancia de al menos 5 pies (1,5 m) en ambos laterales del generador cuando esté en funcionamiento para evitar que se produzca sobrecalentamiento o un incendio. Levantar o colgar el generador PELIGRO Electrocución. En caso de un accidente eléctrico, APAGUE de inmediato la alimentación eléctrica. Use implementos no conductores para liberar a la víctima del conductor. Aplique primeros auxilios y obtenga ayuda médica. No hacerlo ocasionará la muerte o lesiones graves. (000145) ADVERTENCIA Arranque accidental. Desconecte el cable negativo de la batería, luego el cable positivo de la batería cuando trabaje en la unidad. No hacerlo puede ocasionar la muerte o lesiones graves. (000130) • El Código Eléctrico Nacional (NEC por sus siglas en inglés) exige que la estructura y los componentes conductores de electricidad del generador estén correctamente conectados a una toma de tierra aprobada. Es posible que los códigos eléctricos locales también exijan una conexión a tierra adecuada del generador. Consulte con un electricista local cuáles son los requisitos de conexión a tierra de su zona. Manual del usuario del generador portátil ADVERTENCIA Lesiones personales. Si no conecta de manera correcta los cables de elevación, las cadenas o las cintas elevadoras, es posible que pueda provocar daños en la propiedad, lesiones graves o incluso la muerte. (000346) ADVERTENCIA Lesiones personales. Si no utiliza cables, cadenas o cintas con una capacidad nominal de 2000 lbs. (907 kg) de carga de trabajo o una carga superior para levantar o colgar la unidad, es posible que pueda provocar daños en la propiedad, lesiones graves o incluso la muerte. (000347) ADVERTENCIA Lesiones personales. No ponga nunca en funcionamiento el generador mientras está colgado. Si lo hace, puede ocasionar daños en la propiedad, lesiones graves o incluso la muerte. (000348) 3 ADVERTENCIA Lesiones personales. No utilice un gancho de elevación si observa algún daño o alguna señal de corrosión. Si lo hace, puede ocasionar daños en la propiedad, lesiones graves o incluso la muerte. (000349) ADVERTENCIA Lesiones personales. Utilice el gancho de elevación siguiendo las instrucciones que se indican. Si no lo hace, puede ocasionar daños en la propiedad, lesiones graves o incluso la muerte. (000350) ADVERTENCIA Lesiones personales. Compruebe que todos los dispositivos de sujeción están bien apretados antes de levantar la unidad. Si no lo hace, puede ocasionar daños en la propiedad, lesiones graves (000351) o incluso la muerte. Índice de normas 1. Asociación nacional de protección contra incendios (NFPA, por sus siglas en inglés) 70: El CÓDIGO ELÉCTRICO NACIONAL (NEC por sus siglas en inglés) disponible en www.nfpa.org 2. Asociación nacional de protección contra incendios (NFPA, por sus siglas en inglés) 5000: CÓDIGO DE SEGURIDAD Y CONSTRUCCIÓN DE EDIFICIOS disponible en www.nfpa.org 3. Código de Construcción Internacional disponible en www.iccsafe.org 4. Manual de Cableado Agrícola disponible en www.rerc.org, Rural Electricity Resource Council P.O. Box 309 Wilmington, OH 45177-0309 5. ASAE EP-364.2 Instalación y mantenimiento de energía eléctrica de emergencia en granjas disponible en www.asabe.org, Sociedad Americana de Ingenieros Agrícolas y Biológicos, 2950 Niles Road, St. Joseph, MI 49085 6. Seguridad y requisitos de funcionamiento de los generadores portátiles ANSI/PGMA G300 disponible en pgmaonline.com 7. CSA C22.2 100-14 Motores y generadores eléctricos para su uso e instalación siguiendo las normativas del Código eléctrico canadiense. Esta lista no incluye todas las normas aplicables. Consulte con la autoridad que tenga jurisdicción (AHJ, por sus siglas en inglés) si existe cualquier código local o normativa que pueda ser de aplicación en su jurisdicción. Manual del usuario del generador portátil 4 Sección 2 Información general y configuración 27 23 24 25 22 20 14 28 19 26 003436 21 13 12 003441 10 15 17 14 16 18 003442 Figura 2-1. Funciones y controles TABLA 1. Componentes del generador 5 18 Arranque manual 19 Silenciador Toma de corriente de 120/240 voltios CA 30 A con bloqueo 20 Dispositivo antichispas 21 Terminal de tierra 3 Disyuntores de 1 polo (CA) 22 Tiradores 4 Disyuntor de 2 polos 23 Depósito de combustible 5 Toma de corriente con bloqueo de 120 Voltios CA, 30 A 24 Tapón de la gasolina 25 Medidor de combustible 26 Ubicación de la batería (si la hubiese) 27 Soporte de elevación de acero 28 Perilla de desbloqueo del tirador 1 Toma de corriente doble de 120 voltios CA, 20 A 2 6 Control de ralentí 7 Módulo de detección de fallo en el circuito de tierra 8 Disyuntor del módulo de GFCI 9 Contador de horas 10 Palanca del cebador 11 Interruptor de Arranque/Marcha/Parada (Arranque eléctrico) (6,5 kW, Arranque/ Marcha/Parada, solamente arranque manual) 12 Bujía 13 Filtro de aceite 14 Drenaje del aceite 15 Llenado del aceite 16 Filtro de aire 17 Filtro del combustible 003447 Figura 2-2. Etiqueta de identificación de la unidad Manual del usuario del generador portátil 11 3 6 1 4 5 9 2 8 7 003439 Figura 2-3. Panel de control del Serie XC Conozca su generador ADVERTENCIA Consulte el manual. Lea y comprenda completamente el manual antes de usar el producto. No comprender completamente el manual puede provocar la muerte o lesiones graves. (000100a) En la Web de Generac (www.generac.com.) puede encontrar manuales del usuario de reemplazo. Emisiones La Agencia de Protección Ambiental (EPA) de los EE. UU. (y la Junta de Recursos del Aire de California [CARB] para los motores/equipos certificados conforme a las normas de California) requiere(n) que este motor/equipo cumpla las normas para el escape y las emisiones que se evaporan. Ubique en el motor la etiqueta adhesiva sobre cumplimiento de las normas referidas a emisiones para determinar las normas correspondientes. Para información sobre la garantía de emisiones, consulte la garantía de emisiones que se incluye. Es importante seguir las especificaciones de mantenimiento del manual para garantizar que el motor cumpla las normas de emisiones aplicables durante la vida útil del producto. TABLA 2. Especificaciones del producto Especificaciones del generador de 6,5 kW / 8,0 kW Potencia nominal en un factor de potencia de 1,0 6,5kW** / 8,0kW** Vatios de arranque 8,13kW** / 10kW** Tensión de CA nominal 120/240 Carga de CA nominal (120 voltios / 240 voltios) 6,5 kW 8,0 kW 54,2 / 27,1 Amperios** 66,7 / 33,3 Amperios** Frecuencia nominal 60 Hz a 3600 RPM Fase Monofásico Peso de la unidad (Seco) 6,5 kW (solamente arranque manual) 6,5 kW (arranque eléctrico) 8,0 kW (arranque eléctrico) 246 lbs. (111,8 kg) 260 lbs. (117,9 kg) ** Intervalo de temperaturas de funcionamiento: -18 ºC (0 ºF) a 40 ºC (104 ºF). Durante el funcionamiento con temperaturas superiores a 25º C (77º F), es posible que la potencia disminuya. ** La potencia en vatios máxima está sujeta y limitada por, factores como el contenido de BTu del combustible, la altitud, el estado del motor, etc. La potencia máxima disminuye un 3,5 % por cada 1.000 pies (304,8 metros) sobre del nivel del mar y también disminuye un 1% aproximadamente por cada 6º C (10º F) por encima de los 16º C (60º F) de temperatura ambiente. Manual del usuario del generador portátil 6 TABLA 2. Especificaciones del producto Especificaciones del motor de 6,5 kW / 8,0 kW Cilindrada 426 cc Nº de pieza de la bujía 0G0767B Tipo de electrodos de la bujía Champion RC12YC o equivalente Separación de los electrodos de la bujía 0,020 pulgadas (0,51mm) Capacidad del depósito de gasolina 32 L (8,5 galones) Tipo de aceite Consulte el gráfico en la sección Añadir aceite de motor. Capacidad de aceite con cambio de filtro sin cambio de filtro 1,0 L (1,1 qt.) 0,9 L (0,95 qt.) Tiempo de funcionamiento a 50% de carga (6,5/ 8,0kW) 14 horas/11 horas * Vaya a www.generac.com o póngase en contacto con un servicio técnico autorizado independiente para solicitar piezas de repuesto. Enchufes de conexión 120 VCA, 20 A, Toma de corriente doble La toma de 120 voltios está protegida contra sobrecarga con un disyuntor de 20 amperios que se pulsa para reiniciarse. Consulte la Figura 2-4. Cada toma alimentará cargas eléctricas de 120 Voltios CA, monofásicas, de 60 Hz que requieran una corriente de 2400 vatios (2,4 kW) o 20 amperios. Utilice solo cables de 3 conductores con conexión a tierra, de alta calidad y bien aislados con una capacidad nominal de 125 voltios con 20 A (o superior). • Utilice esta toma de corriente para cargas monofásicas de 120 VCA, 60 Hz, que requieran un máximo de 3.600 vatios (3,6 kW) de potencia con 30 A o cargas monofásicas de 240 VCA, 60 Hz, que requieran un máximo de 7.200 vatios (7,2 kW) de potencia con 30 A. La toma está protegida con un disyuntor de balancín de 2 polos, 30 A. 000204 Figura 2-5. Toma de corriente de 120/240 VCA, 30 A NEMA L14-30R Toma de corriente de 120 VCA, 30 Amp 000424 Figura 2-4. Toma de corriente NEMA 5-20R de 120 VCA, 20 A Toma de corriente de 120/240 VCA, 30 Amp Utilice un enchufe NEMA L14-30 con esta toma de corriente (girar para bloquear/desbloquear). Conecte un cable de 4 conductores con conexión a tierra al enchufe y a la carga deseada. La capacidad nominal del cable debería ser de 250 VCA con 30 amperios (o superior). Consulte la Figura 2-5. 7 Utilice un enchufe NEMA L5-30 con esta toma de corriente (girar para bloquear/desbloquear). Conecte un cable de 3 conductores adecuado al enchufe y a la carga deseada. La capacidad nominal del cable debería ser de 125 VCA con 30 A (o superior). Consulte la Figura 2-6. Utilice esta toma de corriente para cargas monofásicas de 120 VCA, 60 Hz, que requieran un máximo de 3.600 vatios (3,6 kW) de potencia con 30 A. La toma está protegida con un disyuntor de 30 A con botón de reinicio. Manual del usuario del generador portátil 000844 Figura 2-6. Toma de corriente de 120 VCA, 30 A NEMA L5-30 Contador de horas El contador de horas realiza un seguimiento de las horas de funcionamiento para el mantenimiento programado. Consulte la Figura 2-7. • La pantalla del mensaje SVC se iluminará una hora antes y una hora después de cada intervalo de 200 horas, proporcionando un plazo de dos horas para realizar la tarea de mantenimiento. Cuando el contador de horas esté en el modo de alerta parpadeante, el mensaje de mantenimiento siempre se alternará con el tiempo transcurrido en horas y minutos. Las horas parpadearán cuatro veces y, a continuación, se alternarán con el mensaje de mantenimiento cuatro veces hasta que el medidor se restablezca automáticamente. • 200 horas - SVC — Cambiar aceite, filtro de aceite, filtro de combustible o bujía. Limpiar la pantalla del supresor de chispas. (Cada 200 horas) NOTA: El icono del reloj de arena parpadeará cuando el motor esté en funcionamiento. Esto significa que el medidor está registrando las horas de funcionamiento. 0000.0 normativas locales, estatales y federales. El módulo de detección de fallo en el circuito de conexión a tierra es para todas las tomas. En el caso de que se produzca un fallo de conexión a tierra, el GFCI se activará y detendrá la corriente eléctrica para evitar que se produzcan lesiones graves. El GFCI controla continuamente la corriente del circuito. Si la corriente del circuito es diferente a la corriente de retorno, el GFCI desconecta la alimentación mediante la activación del disyuntor principal en el panel de control del generador. Un GFCI NO protege de sobrecargas en el circuito, cortocircuitos ni descargas eléctricas. Una descarga eléctrica se puede producir cuando una persona toca cables cargados eléctricamente mientras se encuentra sobre una superficie no conductora, como por ejemplo un suelo de madera. Pruebe el módulo de GFCI antes de cada uso. Consulte la Figura 2-8. 1. Arranque el generador. 2. Enchufe la lámpara de prueba en la toma doble. La lampara debería encenderse. 3. Pulse el botón TEST (Prueba) en el GFCI para activar el dispositivo. A continuación el disyuntor principal debería “activarse”. Esto se indica con el movimiento de la palanca del accionador en la posición OFF. 4. De esta manera la corriente eléctrica se detiene haciendo que la lámpara se apague. Si el disyuntor principal no se “activa”, esto significa que el GFCI no funciona y el generador no debe utilizarse. Póngase en contacto con el servicio técnico autorizado independiente. 5. Para restaurar la corriente eléctrica, coloque la palanca del accionador en la posición 'ON'. La palanca debería permanecer bloqueada en su posición. Si no es así, bien el GFCI o bien el disyuntor principal tienen algún fallo y deberán ser reemplazados. Póngase en contacto con el servicio técnico autorizado independiente. 6. Este GFCI está protegido contra sobrecargas por un disyuntor principal de 6,5kW, 30 A o 8,0kW, 35A/240V. 7. El GFCI cuenta con luces de estado LED para las funciones de Monitor automático y Fin de la vida útil. 000205 Figura 2-7. Contador de horas Módulo de detección de fallo en el circuito de tierra Esta unidad incluye un interruptor del circuito de fallo de conexión a tierra (GFCI). Este dispositivo cumple con los códigos y Manual del usuario del generador portátil 8 Bolsa de tornillería Horquilla (4) 004285 Ctd 2 Eje (5) 1 Arandela plana 5/8” (6) 2 Tornillo de 54 mm (7) 8 Conjunto de tornillo de conexión (9) 2 Tornillo de 54 mm (10) 2 Tuerca (11) 6 Figura 2-8. Probar el GFCI Control de ralentí automático (si hubiese) Esta función mejora el ahorro de combustible. Cuando este interruptor se coloca en la posición ON, el motor funcionará a una velocidad de motor normal rápida cuando está conectado a una carga eléctrica. Cuando se retira la carga eléctrica, el motor funcionará a una velocidad reducida. Con el interruptor en la posición OFF, el motor funciona de manera continua a una velocidad de motor normal rápida. Coloque siempre el interruptor en la posición OFF cuando arranque y pare el motor. Consulte la Figura 2-8. Sacar el contenido de la caja 1. Abra la caja de cartón completamente cortando cada esquina de arriba a abajo. 2. Saque y compruebe el contenido de la caja antes del montaje. La caja debe contener lo siguiente: TABLA 3. Accesorios Artículo 9 Ctd Unidad principal 1 Manual del usuario 1 Manual del motor 1 Cuarto de aceite SAE 1 Filtro de aceite 1 Filtro de aire 1 Bujía 1 Llave de bujías 1 Toalla para uso industrial 1 Tapa superior (8) 2 Rueda (1) 2 Pata para la estructura (2) 2 Conjunto de elevación de acero (3) 2 3. Si faltara algún artículo de su caja, póngase en contacto con el servicio de atención al cliente de Generac llamando al 1-888-436-3722 y cuando llame tenga a mano los números de modelo y serie. 4. Escriba el número de modelo, número de serie y fecha de compra que aparecen en la portada de este manual. Montaje ADVERTENCIA Consulte el manual. Lea y comprenda completamente el manual antes de usar el producto. No comprender completamente el manual puede provocar la muerte o lesiones graves. (000100a) Si tiene problemas con el montaje, póngase en contacto con el servicio de atención al cliente de Generac llamando al 1-888GENERAC (1-888-436-3722). Cuando llame para solicitar asistencia, tenga a mano los números de modelo y de serie. Las siguientes herramientas son necesarias para instalar el kit de accesorios. • Destornillador (1) • Llave de 8 mm (2) • Llave de 13 mm (2) Consulte la Figura 2-9. Instale el soporte de elevación de la siguiente manera: 1. Instale cada una de las mitades del soporte de elevación (3) debajo de la estructura y colóquelos fijando sin apretar los tornillos de 45 mm (7) y la tuerca (11) a través de los orificios que hay en la estructura. 2. Inserte el tornillo de 20 mm (10) y la tuerca (11) en los agujeros superiores de las dos mitades del soporte de elevación. 3. Apriete todos los tornillos hasta que queden fijados. 4. Alinee cada una de las tapas superiores (8) con los agujeros del soporte de elevación inferior (3). Inserte el cilindro del tornillo de conexión (9) y fíjelo con el tornillo de conexión 89). Manual del usuario del generador portátil 7 11 10 9 9 8 3 11 003759 Figura 2-9. Soporte de elevación de acero NOTA: Las ruedas no se han diseñado para su circulación sobre carreteras. Consulte la Figura 2-10. Instale las ruedas tal y como se indica a continuación: 1. Deslice el eje (5) por los agujeros del eje de la estructura del generador. 2. Deslice la rueda (1) y una arandela plana de 5/8" (6) por el eje. 3. Sujételo con la horquilla (4). Repita este procedimiento en el lado opuesto. Instale el conjunto de patas para la estructura de la siguiente manera: 1. Alinee la pata de la estructura (2) con los agujeros de la estructura y fíjelas con tornillos de 45 mm (7). 3 5 1 6 2 7 4 003448 Figura 2-10. Ruedas y patas Conexión del cable de la batería (si se incluye) PRECAUCIÓN Daños en el equipo. No realice las conexiones de la batería a la inversa. Si lo hace, el equipo podría resultar dañado. (000167a) La unidad se ha enviado con los cables de la batería desconectados. Necesitará dos llaves de tubo de 8 mm para conectar los cables de la batería. Consulte la Figura 4-5. 1. Corte las bridas de sujeción de los cables de la batería y retire la cubierta roja del borne de la batería. 2. En primer lugar, conecte los cables rojos al borne positivo (+) de la batería con el perno y la tuerca incluidos. 3. Compruebe que las conexiones estén bien apretadas y coloque la funda de goma en el borne positivo (+) de la batería y los tornillos de conexión. Manual del usuario del generador portátil 4. Conecte el cable negro al borne negativo (-) de la batería con el perno y la tuerca que se incluyen. Coloque la funda de goma en el borne negativo (-) de la batería y los tornillos de conexión. 5. Compruebe que todas las conexiones sean seguras. NOTA: Si no es posible arrancar el motor con la batería, cámbielo por un cargador de 12V adecuado o arranque el generador y deje que funcione hasta que se cargue. Añadir aceite de motor PRECAUCIÓN Daño al motor. Verifique el tipo y la cantidad apropiados del aceite del motor antes de poner en marcha el motor. No hacer esto puede provocar daños al motor. (000135) 1. Coloque el generador sobre una superficie plana. 2. Verifique que el área de llenado de aceite esté limpia. 10 3. Retire la tapa de llenado de aceite y limpie la varilla de medición. Consulte la Figura 2-11. 7. Coloque la tapa de llenado del aceite/ varilla de nivel y apriétela firmemente con la mano. Combustible PELIGRO Explosión e incendio. El combustible y los vapores son extremadamente inflamables y explosivos. Añada combustible en una zona bien ventilada. Mantenga alejados el fuego y las chispas. No hacerlo puede ocasionar la muerte o lesiones graves. (000105) PELIGRO 000115 Figura 2-11. Sacar la varilla 4. Añada el aceite de motor recomendado. Las temperaturas exteriores determinan la viscosidad adecuada del aceite para el motor. Use esta tabla para seleccionar la mejor viscosidad. NOTA: Use aceite a base de petróleo (incluida) para facilitar el rodaje del motor antes de utilizar aceite sintético. . SAE 30 10W-30 5W-30 sintético Intervalo de temperatura de uso esperada 000399 NOTA: Algunas unidades cuentan con más de un lugar por el que se puede añadir el aceite. En estos casos, solo se necesita utilizar un punto de llenado de aceite. 5. Introduzca la varilla en el cuello de llenado de aceite. El nivel de aceite se comprueba con la varilla de medición completamente insertada. 6. Consulte la Figura 2-12. Retire la varilla y compruebe que el nivel de aceite se encuentra dentro del rango de funcionamiento seguro. Explosión e incendio. No sobrepase el nivel del depósito de combustible. Llene el depósito y deje sin llenar media pulgada de la parte superior del mismo para que quede espacio para la expansión del mismo. Si lo llena en exceso puede hacer que el combustible se derrame en el motor provocando un incendio o explosión, lo cual podría provocar la muerte o lesiones graves. (000166b) El combustible debe cumplir con los siguientes requisitos: • Gasolina limpia, en buen estado y sin plomo. • Un octanaje mínimo de 87/87 AKI (RON 91). • También se puede utilizar gasolina con un porcentaje de hasta el 10% de etanol (gasohol), cuando esté disponible, se recomienda utilizar combustible premium sin etanol. • NO use E85. • NO mezcle aceite en la gasolina. • NO modifique el motor para que funcione con combustibles alternativos. Estabilice el combustible antes de almacenarlo. 1. Verifique que la unidad está apagada y espere a que se enfríe un mínimo de dos minutos antes de cargar el combustible. 2. Coloque la unidad sobre una superficie nivelada y en un área bien ventilada. 3. Limpie el área alrededor de la tapa del combustible y quite la tapa con cuidado. 4. Añada lentamente el combustible recomendado. No llene por encima del borde interno. Consulte la Figura 2-13. 5. Colocación de la tapa del combustible. A 000230 Figura 2-13. Añadir combustible recomendado 003620 Figura 2-12. Rango de funcionamiento seguro 11 NOTA: Si se derrama combustible, espere hasta que se evapore antes de encender el motor. Manual del usuario del generador portátil NOTA IMPORTANTE: Es importante evitar la formación de acumulaciones de residuos pegajosos en los componentes del sistema de combustible como el carburador, la manguera o el depósito durante el almacenamiento. Los combustibles mezclados con alcohol (gashol, etanol o metanol) pueden atraer la humedad, lo que provoca la separación y la formación de ácidos durante el almacenamiento. El gas ácido puede dañar el sistema de combustible de un motor durante el almacenamiento. Para evitar problemas con el motor, debería vaciar el sistema de combustible antes de almacenarlo durante 30 días o más. Consulte la sección Almacenamiento. Nunca utilice productos para la limpieza del motor o carburador en el depósito de combustible ya que podrían provocar daños permanentes. Manual del usuario del generador portátil 12 Sección 3 Funcionamiento Preguntas sobre uso y funcionamiento PRECAUCIÓN Si tiene preguntas o dudas acerca del funcionamiento y mantenimiento del equipo, póngase en contacto con el servicio de atención al cliente de Generac llamando al 1-888-GENERAC (1-888-436-3722). Antes de arrancar el motor 1. Verifique que el nivel de aceite del motor sea el correcto. 2. Verifique que el nivel del combustible sea el correcto. 3. Verifique que la unidad esté segura sobre una superficie nivelada, en un espacio exterior y en una zona bien ventilada. Preparación del generador para su uso PELIGRO Asfixia. Los motores funcionando producen monóxido de carbono, un gas incoloro, inodoro, y venenoso. El monóxido de carbono, si no se evita, ocasionará la muerte o lesiones graves. (000103) PELIGRO Asfixia. El sistema de escape debe mantenerse adecuadamente. No altere ni modifique el sistema de escape ya que podría hacer que su funcionamiento sea inseguro o que no cumpla con los códigos y/o normativas locales. En caso de no hacerlo, podría provocarse la muerte o lesiones graves. (000179b) Daños a los equipos y la propiedad. Desconecte las cargas eléctricas antes de poner en marcha o parar la unidad. No hacer esto puede provocar daños al equipo y la propiedad. (000136) Conexión a tierra del generador cuando se utiliza como aparato portátil El generador está equipado con un terminal para la conexión de un sistema de electrodos de conexión a tierra. Article 250.34 (A) No se requiere que la estructura del generador se conecte a un sistema de electrodos de conexión a tierra cuando el generador solamente suministra alimentación a un equipo conectado mediante enchufe y cable de alimentación a través de las tomas del generador. Cuando el generador suministra energía a un interruptor de transferencia manual de 3 polos o a tableros de distribución eléctrica para suministrar alimentación temporalmente, debe instalarse un sistema de electrodos de conexión a tierra y conectarse a una terminal de electrodos de conexión a tierra en el generador. Consulte NEC 250.30, 250.34 y 250.52 para aclarar cualquier duda. Consulte la Figura 3-1. • Conexión neutral a estructura ADVERTENCIA Riesgo de incendio. No use el generador sin el supresor de chispas. De lo contrario, pueden producirse lesiones graves o la muerte. (000118a) ADVERTENCIA Asfixia. En interiores, utilice siempre una alarma de monóxido de carbono alimentada por pilas e instalada de acuerdo con las instrucciones de los fabricantes. En caso de no hacerlo, podría provocarse (000178a) la muerte o lesiones graves. ADVERTENCIA Riesgo de incendio. Las superficies calientes pueden encender combustibles, produciendo un incendio. El incendio puede ocasionar la muerte o lesiones graves. (000110) ADVERTENCIA Superficies calientes. Al usar la máquina, no toque las superficies calientes. Mantenga la máquina alejada de los combustibles durante el uso. Las superficies calientes pueden ocasionar quemaduras (000108) graves o incendio. Manual del usuario del generador portátil 000227 Figura 3-1.Conexión a tierra del generador Requisitos especiales Revise todos los decretos, códigos locales o normativas de la Administración de Seguridad y Salud Ocupacional estatales o federales (OSHA) que se apliquen al uso previsto del generador. Es posible que se apliquen más normativas si el generador se utiliza en una obra. Consulte a un electricista cualificado, un inspector de instalaciones eléctricas o la agencia local que tenga potestad para imponer requisitos adicionales que puedan ser específicos para su área, como por ejemplo si es necesario que el generador esté registrado con la empresa encargada de suministrar la electricidad en su zona. 13 Conexión del generador al sistema eléctrico de un edificio Se recomienda usar un interruptor de transferencia manual al conectar directamente al sistema eléctrico de un edificio. Para conectar un generador portátil al sistema eléctrico de un edificio, deben cumplirse estrictamente las normativas y la legislación sobre instalaciones eléctricas locales y nacionales, y esta conexión debe realizarla un electricista cualificado. Conexión de las cargas eléctricas NO conecte cargas de 240 voltios a tomas de 120 voltios. NO conecte cargas trifásicas al generador. NO conecte cargas de 50 Hz al generador. Deje que la unidad se estabilice y se caliente durante unos minutos antes de arrancarla. Enchufe y conecte las cargas eléctricas de 120 o 240 voltios de CA, monofásicas de 60 Hz. Añada la potencia nominal (o amperios) de todas las cargas que se conectarán a la vez. El total no debe ser superior a (a) la capacidad de voltaje/amperaje nominal del generador o (b) la potencia del disyuntor de la toma que suministra la energía. Consulte Conozca los límites del generador. Conozca los límites del generador Sobrecargar un generador en exceso puede provocar daños en el generador y en los dispositivos eléctricos conectados. Tenga en cuenta lo siguiente para evitar sobrecargas: • Sume la potencia total de todos los dispositivos eléctricos que se conectarán a la vez. Este total NO debería superar la potencia del generador. • La potencia nominal de las luces se puede obtener de las bombillas. La potencia nominal de las herramientas, electrodomésticos y motores se encuentra en la etiqueta o adhesivo de datos pegados en el dispositivo. • Si los electrodomésticos, herramientas o motores no indican la potencia, multiplique los voltios por la capacidad nominal en amperios para determinar los vatios (voltios x amperios = vatios). • Algunos motores eléctricos, como los de inducción, requieren tres veces más vatios de potencia para el arranque que para el funcionamiento. Esta sobrecarga sólo dura unos pocos segundos al arrancar este tipo de motores. Asegúrese de disponer de una potencia de arranque elevada cuando seleccione los dispositivos eléctricos que se conectarán al generador. 1. Calcule los vatios necesarios para arrancar el motor más grande. 14 2. Sume a esa cifra los vatios de funcionamiento del resto de cargas conectadas. Hemos incluido la Guía de referencia de la potencia para ayudarle a determinar el número de dispositivos que el generador puede hacer funcionar a la vez. NOTA: Todas las cifras son aproximadas. Consulte la etiqueta de datos del electrodoméstico para obtener los requisitos de potencia. Tabla 3: Guía de referencia de la potencia Dispositivo Vatios de funcionamiento *Aire acondicionado (12.000 Btu) 1700 *Aire acondicionado (24.000 Btu) 3800 *Aire acondicionado (40.000 Btu) 6000 Cargador de batería (20 amperios) 500 Lijadora de correa (3") 1000 Motosierra 1200 Sierra circular (6-1/2") de 800 a 1000 *Secadora (eléctrica) 5750 *Secadora (gas) 700 *Lavadora 1150 Cafetera 1750 *Compresor (1 HP) 2000 *Compresor (3/4 HP) 1800 *Compresor (1/2 HP) 1400 Plancha para el pelo 700 Deshumidificador 650 Lijadora de disco (9") 1200 Cortabordes 500 Manta eléctrica 400 Pistola eléctrica para clavos 1200 Cocina eléctrica (por elemento) 1500 Sartén eléctrica 1250 *Congelador 700 *Extractor de humos (3/5 HP) Sistema de apertura del garaje 875 de 500 a 750 Secador de pelo 1200 Taladro de mano de 250 a 1100 Cortasetos 450 Llave de impacto 500 Plancha 1200 *Bomba de chorro 800 Cortacésped 1200 Bombilla 100 Manual del usuario del generador portátil Horno microondas de 700 a 1000 *Enfriador de leche 1100 Quemador de petróleo en el horno 300 Estufa de petróleo (140.000 Btu) 400 Estufa de petróleo (85.000 Btu) 225 Estufa de petróleo (30.000 Btu) 150 *Pistola de pintar, sin aire (1/3 HP) 600 Pistola de pintar, sin aire (de mano) 150 Radio 4. Gire el interruptor de PARO/MARCHA del motor a la posición RUN (Marcha). Consulte la Tabla 1: Componentes del generador. CERRADO ON OFF de 50 a 200 *Refrigerador 700 Olla de cocción lenta 200 *Bomba sumergible (1-1/2 HP) 2800 *Bomba sumergible (1 HP) 2000 Figura 3-2.Controles del motor *Bomba sumergible (1/2 HP) 1500 5. Mueva la palanca del cebador (B) a la izquierda hasta la posición Full CHOKE (Cebado completo). Consulte la Figura 3-2. 6. Consulte la Figura 3-2. Sujete la cuerda de arranque (C) y tire de ella ligeramente hasta que note que la resistencia aumenta. Tire rápidamente hacia arriba y hacia afuera. 7. Cuando el motor arranque, mueva la palanca del cebador a la posición 1/2 CHOKE (Cebado medio) hasta que el motor funcione de manera suave y, a continuación, mueva la palanca hasta la posición OPEN (derecha). Si el funcionamiento del motor decae, mueva de nuevo la palanca del cebador a la posición 1/2-CHOKE (Cebado medio) hasta que el motor funcione de manera suave y, a continuación, mueva la palanca hasta la posición OPEN (derecha). NOTA: Si el motor arranca, pero no sigue funcionando, mueva la palanca del cebador a la posición Full CHOKE (Cebado completo) a la izquierda y repita las instrucciones de arranque. NOTA IMPORTANTE: No sobrecargue el generador ni las tomas de corriente individuales del panel. Estas tomas están protegidas contra sobrecargas con disyuntores pulsar-para-reiniciar. Si se supera el amperaje de alguno de los disyuntores, el disyuntor afectado se abrirá y se perderá la potencia eléctrica a la toma de corriente. Lea detenidamente la sección Conozca los límites del generador. *Bomba de sumidero de 800 a 1050 *Sierra de mesa (10”) de 1750 a 2000 Televisión de 200 a 500 Tostadora de 1000 a 1650 Cortacésped de hilo 500 * Multiplique por 3 los vatios de la lista para calcular los vatios necesarios para arrancar estos dispositivos. Transporte o inclinación de la unidad No almacene ni transporte la unidad con un ángulo superior a 15 grados. Arranque de motores con el tirador de arranque ADVERTENCIA Riesgo del arranque con cuerda. El arranque con cuerda puede reaccionar inesperadamente. El contragolpe puede ocasionar la muerte o lesiones graves. (000183) PRECAUCIÓN Daños a los equipos y la propiedad. Desconecte las cargas eléctricas antes de poner en marcha o parar la unidad. No hacer esto puede provocar daños al equipo y la propiedad. (000136) 003449 B C A . 1. Desconecte todas las cargas eléctricas de las tomas de corriente de la unidad antes de arrancar el motor. 2. Coloque el generador sobre una superficie plana. 3. Gire la válvula de cierre de combustible (A) en el sentido contrario a las agujas del reloj a la posición ON (Abierto). Consulte la Figura 3-2. Manual del usuario del generador portátil 15 Arranque de motores con arranque eléctrico Apagar el generador PRECAUCIÓN PRECAUCIÓN Daños a los equipos y la propiedad. Desconecte las cargas eléctricas antes de poner en marcha o parar la unidad. No hacer esto puede provocar daños al equipo y la propiedad. (000136) 1. Desconecte todas las cargas eléctricas de las tomas de corriente de la unidad antes de arrancar el motor. 2. Coloque el generador sobre una superficie plana. 3. Gire la válvula de cierre de combustible (A) en el sentido contrario a las agujas del reloj a la posición ON (Abierto). Consulte la Figura 3-2. 4. Mueva la palanca del cebador (B) a la izquierda hasta la posición Full CHOKE (Cebado completo). Consulte la Figura 3-2. 5. Mantenga pulsado el interruptor de ARRANQUE/MARCHA/PARADA en la posición START (Arranque). Cuando el motor arranque, suelte el interruptor a la posición RUN (Marcha). 6. Cuando el motor arranque, mueva la palanca del cebador a la posición 1/2 CHOKE (Cebado medio) hasta que el motor funcione de manera suave y, a continuación, mueva la palanca hasta la posición OPEN (derecha). Si el funcionamiento del motor decae, mueva de nuevo la palanca del cebador a la posición 1/2-CHOKE (Cebado medio) hasta que el motor funcione de manera suave y, a continuación, mueva la palanca hasta la posición OPEN (derecha). NOTA: Si el motor arranca, pero no sigue funcionando, mueva la palanca del cebador a la posición Full CHOKE (Cebado completo) a la izquierda y repita las instrucciones de arranque. 16 Daños a los equipos y la propiedad. Desconecte las cargas eléctricas antes de poner en marcha o parar la unidad. No hacer esto puede provocar daños al equipo y la propiedad. (000136) 1. Cierre todas las cargas y desconecte todas las cargas eléctricas de las tomas de corriente del panel del generador. 2. Deje que el motor funcione sin cargas durante varios minutos para que se estabilicen las temperaturas internas del motor y del generador. 3. Gire el interruptor de ARRANQUE/ MARCHA/PARADA a la posición STOP (Parada). 4. Gire la válvula de cierre de combustible en el sentido de las agujas del reloj a la posición OFF (cerrado). NOTA: En condiciones normales de uso, cierre la válvula de combustible y deje que la cubeta de combustible del generador se quede sin combustible. En caso de emergencia, gire el interruptor a la posición STOP (Parada). Sistema de cierre por nivel bajo de aceite El motor está equipado con un sensor de presión de aceite baja que apaga el motor automáticamente cuando el nivel de aceite cae por debajo de un nivel especificado. El motor no funcionará hasta que se añada aceite hasta el nivel adecuado. Si el motor se apaga y hay combustible suficiente, compruebe el nivel de aceite del motor. Manual del usuario del generador portátil Sección 4 Mantenimiento y solución de problemas Mantenimiento El mantenimiento regular mejorará el rendimiento y prolongará la vida útil del motor/ equipo. Generac Power Systems, Inc. recomienda que todo el trabajo de mantenimiento sea efectuado por un Concesionario de servicio autorizado independiente (IASD). El mantenimiento regular, sustitución o reparación de los dispositivos y sistemas de control de emisiones puede ser efectuado por cualquier taller de reparaciones o mecánico elegido por el propietario. Sin embargo, para obtener servicio de garantía gratuito, el trabajo debe ser efectuado por un Concesionario de servicio autorizado independiente (IASD). Vea la garantía de emisiones. NOTA: Si tiene preguntas acerca de cómo reemplazar algún componente, llame al 1-888-GENERAC (1-888-436-3722). Programa de mantenimiento Consulte los intervalos del programa de mantenimiento, lo que ocurra primero según el uso. NOTA: Las condiciones adversas requerirán un mantenimiento más frecuente. NOTA: Vaya a www.generac.com o póngase en contacto con un servicio técnico autorizado independiente para solicitar piezas de repuesto. NOTA: Todas las operaciones de mantenimiento y ajustes necesarios deben realizarse cada temporada, tal y como se detalla en el siguiente gráfico. En cada uso Comprobar el nivel de aceite del motor Cada 100 horas o en cada estación* Limpiar la pantalla del supresor de chispas Cada estación Comprobar la holgura de la válvula*** Cada 200 horas o en cada estación Cambio de aceite ‡ Sustituir la bujía Sustituir el filtro del combustible Verificar/limpiar el filtro de aire Manual del usuario del generador portátil ‡ Cambiar el aceite después de las 25 primeras horas de funcionamiento y, después, en cada estación. * Cambiar el aceite y el filtro de aceite cada mes cuando el generador funcione con cargas pesadas o bajo altas temperaturas. ** Limpiar el generador con más frecuencia en condiciones de funcionamiento con suciedad o polvo. Sustituya las piezas del filtro de aire si no se pueden limpiar correctamente. *** Comprobar la holgura de la válvula y ajustarla si fuera necesario después de las 50 primeras horas de funcionamiento y, después, cada 400 horas. Mantenimiento preventivo La suciedad o los residuos pueden hacer que el equipo no funcione de manera correcta y provocar daños en este. Limpie el generador a diario o antes de cada uso. Mantenga la zona alrededor y detrás del silenciador sin suciedad de combustible. Revise las ranuras y aberturas del aire de enfriamiento del generador. ADVERTENCIA Lesiones personales. No inserte objetos a través de las ranuras de enfriamiento de la unidad. El generador puede arrancar en cualquier momento y provocar la muerte, lesiones graves y daños en la unidad. (000142a) • Utilice un paño húmedo para limpiar las superficies exteriores. • Utilice un cepillo de cerdas suaves para retirar la suciedad endurecida, el aceite, etc. • Utilice una aspiradora para eliminar la suciedad y los residuos sueltos. • Se puede utilizar aire a baja presión (que no supere los 25 psi) para eliminar la suciedad. Inspeccione las ranuras del aire de refrigeración y las aberturas del generador. Estas aberturas deben mantenerse limpias y sin obstrucciones. NOTA: NO utilice una manguera de jardín para limpiar el generador. El agua podría entrar en el sistema del combustible del motor y causar problemas. Si el agua entrara en el generador a través de las ranuras del aire de refrigeración, parte de esta agua podría quedar retenida en huecos y hendiduras del aislante del bobinado del rotor y del estator. La acumulación de agua y suciedad en los bobinados internos podría disminuir la resistencia del aislante de estos bobinados. 17 Mantenimiento del motor 4. Introduzca la varilla en el cuello de llenado de aceite. Retire la varilla y compruebe que el nivel de aceite se encuentra dentro del rango de funcionamiento seguro. Consulte la Figura 4-2. ADVERTENCIA Arranque accidental. Desconecte los cables de las bujías al trabajar en la unidad. No hacerlo puede ocasionar la muerte o lesiones graves. (000141) Recomendaciones sobre el aceite del motor Para mantener la garantía del producto,el aceite de motor se debe mantener conforme a las recomendaciones de este manual. Para su comodidad, hay disponibles kits de mantenimiento para usar en este producto que incluyen aceite de motor, filtro de aceite, bujía(s), una toalla de taller y embudo. Estos kits se pueden obtener de un Concesionario de servicio autorizado independiente (IASD). SAE 30 10W-30 003620 Figura 4-2. Rango de funcionamiento seguro 5. Añada el aceite de motor recomendado según sea necesario. 6. Vuelva a colocar la tapa de llenado del aceite y apriétela de manera manual. NOTA: Algunas unidades cuentan con más de un lugar por el que se puede añadir el aceite. En estos casos, solo se necesita utilizar un punto de llenado de aceite. 5W-30 sintético Cambiar filtro de aceite y del aceite del motor Intervalo de temperatura de uso esperada 000399 . Comprobación del nivel de aceite en el motor ADVERTENCIA ADVERTENCIA Arranque accidental. Desconecte los cables de las bujías al trabajar en la unidad. No hacerlo puede ocasionar la muerte o lesiones graves. (000141) ADVERTENCIA Riesgo de quemaduras. Espere a que el motor se enfríe antes de vaciar el aceite o el refrigerante. No hacerlo puede ocasionar la muerte o lesiones graves. (000139) El nivel de aceite se debe verificar antes de cada uso o al menos cada 8 horas de funcionamiento. 1. Coloque el generador sobre una superficie plana. 2. Limpie el área alrededor de la boca de llenado de aceite. 3. Consulte la Figura 4-1. Quite la tapa de llenado de aceite y limpie la varilla de medición. 000115 Riesgo de quemaduras. Espere a que el motor se enfríe antes de vaciar el aceite o el refrigerante. No hacerlo puede ocasionar la muerte o lesiones graves. (000139) Si el generador se utiliza en lugares con mucho polvo o suciedad, o en un clima extremadamente cálido, cambie el aceite con más frecuencia. NOTA: ¡No contamine! Preserve los recursos. Lleve el aceite usado a centros de recogida. Cambie el aceite cuando el motor esté frío tal y como se especifica a continuación: 1. Coloque el generador sobre una superficie plana. 2. Desconecte el cable de la bujía y colóquelo donde no pueda hacer contacto con la bujía. 3. Limpie el área alrededor del tapón de drenaje y de la boca de llenado de aceite. 4. Quite la tapa de la boca de llenado de aceite. 5. Retire el tapón de la manguera de drenaje de aceite y drene el aceite completamente en un recipiente adecuado. Figura 4-1. Cómo añadir aceite al motor 18 Manual del usuario del generador portátil 6. Vuelva a colocar el tapón de la manguera de drenaje de aceite y apriételo firmemente. 7. Coloque un recipiente adecuado debajo del filtro de aceite y gire el filtro en el sentido contrario al de las agujas del reloj para quitarlo. Deséchelo siguiendo las normativas locales vigentes. 8. Recubra la junta del nuevo filtro con aceite de motor limpio. Gire el filtro en el sentido de las agujas del reloj hasta que la junta entre en contacto ligeramente con el adaptador de filtro. A continuación, apriete con un giro adicional de 3/4. 9. Vierta lentamente el aceite en la boca de llenado hasta alcanzar el nivel de aceite adecuado para el funcionamiento en la varilla. NO llene en exceso. 10. Coloque nuevamente la tapa y apriétela bien. 11. Limpie el aceite que pueda haberse derramado. 12. Deshágase del aceite de acuerdo con las regulaciones locales. Filtro de aire El motor no funcionará correctamente y puede sufrir daños si se utiliza con un filtro de aire sucio. Reemplácelo o límpielo más a menudo si utiliza la unidad bajo condiciones de mucha suciedad o polvo. Para realizar limpiar/reemplazar el filtro de aire: 1. Consulte la Figura 4-3. Retire la cubierta del filtro de aire (A) y el filtro (B). 2. Con cuidado, golpee el filtro sobre una superficie sólida. Si está muy sucio, cámbielo por un filtro nuevo. 3. Limpie la cubierta del filtro de aire antes de instalarla. NOTA: Para solicitar un nuevo filtro de aire, póngase en contacto con el centro de servicio técnico autorizado independiente más cercano llamando al 1-888-GENERAC (1-888-436-3722). B A 003466 Figura 4-3. Conjunto del filtro de aire Manual del usuario del generador portátil Mantenimiento de la bujía Para realizar el mantenimiento a la bujía: 1. Limpie la zona que rodea la bujía. 2. Retire e inspeccione la bujía. 3. Compruebe la separación entre electrodos con un calibrador de alambre y configúrela a la medida de 0,020 pulg. (0,51 mm). Consulte la Figura 4-4. 000211 000211 Figura 4-4. Bujía NOTA: Cambie la bujía si los electrodos están carbonizados o quemados o si la porcelana está rota. Reemplace la bujía EXCLUSIVAMENTE con otra bujía recomendada. Consulte las especificaciones. 4. Instale la bujía y apriétela manualmente y gírela 3/8 a 1/2 vuelta utilizando la llave para bujías. Sustitución de la batería (si procede) NOTA: La batería incluida con el generador se entrega cargada totalmente. Una batería puede perder parte de la carga cuando no se utiliza durante periodos de tiempo prolongados. Es posible que tenga que cargar la batería antes de utilizarla por primera vez. Al poner en funcionamiento el generador, la batería se cargará. ADVERTENCIA Arranque accidental. Desconecte el cable negativo de la batería, luego el cable positivo de la batería cuando trabaje en la unidad. No hacerlo puede ocasionar la muerte o lesiones graves. (000130) Consulte la Figura 4-5. 1. Desconecte y retire los tornillos de montaje de la batería (8 mm) y el cable NEGRO (B) del borne NEGATIVO (-) de la batería. 2. Mueva la funda protectora roja (A) y quite los tornillos de montaje de la batería (8 mm) y el cable ROJO (C) del borne POSITIVO (+) de la batería. 3. Instale la nueva batería. Sujete la batería con la cinta. 4. Conecte el cable ROJO con el borne POSITIVO (+) de la batería (C). Coloque la funda de goma (A) en los tornillos de conexión. 19 5. Conecte el cable NEGRO con el borne NEGATIVO (-) de la batería (B). Inspección del filtro del dispositivo antichispas ADVERTENCIA A Superficies calientes. Al usar la máquina, no toque las superficies calientes. Mantenga la máquina alejada de los combustibles durante el uso. Las superficies calientes pueden ocasionar quemaduras (000108) graves o incendio. B C 003760 Figura 4-5. Conexión de la batería ADVERTENCIA Peligro ambiental. Siempre recicle las baterías en un centro de reciclado oficial de acuerdo con todas las leyes y reglamentos locales. No hacerlo puede ocasionar daños ambientales, la muerte o lesiones graves. (000228) 1. Afloje la abrazadera (A). Consulte la Figura 4-6. 2. Revise el cono (C) y sustitúyalo si está desgastado, perforado o dañado de alguna manera. Si el cono no está dañado, límpielo con un disolvente comercial. 3. Sustituya el cono del supresor de chispas (C) y el collar (B). Sujételo con la abrazadera (A). B Inspección del silenciador y del dispositivo antichispas NOTA: Constituye una infracción del artículo 4442 del Código de Recursos Públicos de California utilizar o hacer funcionar el motor en la proximidades de terrenos boscosos o de rastrojos o que estén cubiertos de hierba a menos que el sistema de escape esté equipado con un dispositivo antichispas, tal y como se define en la Sección 4442. Además, este motor debe mantenerse en un buen estado de funcionamiento. Otros estados o jurisdicciones federales pueden aplicar normas legales similares. Póngase en contacto con el fabricante original del equipo, el vendedor o el distribuidor para obtener un dispositivo antichispas para el sistema de escape instalado en este motor. NOTA: Use SOLAMENTE equipo o repuestos originales. Inspeccione el silenciador por si tuviese grietas, corrosión u otros daños. Retire el dispositivo antichispas, si lo hubiese, y realice una inspección en busca de daños o bloqueo por la presencia de carbón. Reemplace las piezas si ello es necesario. 20 C A 003467 Figura 4-6. Pantalla del supresor de chispas Holgura de la válvula Importante: Póngase en contacto con un servicio técnico independiente autorizado para obtener ayuda. Este es un paso muy importante para asegurar una larga vida útil del motor. Compruebe la holgura de la válvula después de las 50 primeras horas de funcionamiento. Ajústela según sea necesario. • Entrada — 0,05 ± 0,08 mm, (0,002" ± 0,003" pulgadas) • Salida — 0,05 ± 0,08 mm, (0,002" ± 0,003" pulgadas) Manual del usuario del generador portátil Almacenamiento General PELIGRO Explosión e incendio. El combustible y los vapores son extremadamente inflamables y explosivos. Almacene el combustible en una zona bien ventilada. Mantenga alejados el fuego y las chispas. No hacerlo ocasionará la (000143) muerte o lesiones graves. ADVERTENCIA Riesgo de incendio. Verifique que la máquina se haya enfriado apropiadamente antes de instalar una cubierta y almacenar la máquina. Las superficies calientes pueden ocasionar un incendio. (000109) Se recomienda arrancar el generador una vez cada 30 días, y debería funcionar durante 30 minutos. Si no puede hacerlo, consulte la siguiente lista para preparar la unidad para su almacenamiento. • NO coloque una cubierta de almacenamiento en un generador caliente. Espere a que el generador se enfríe completamente antes de almacenarlo. • NO guarde combustible de una temporada a otra a menos que se trate de un modo adecuado. • Sustituya el contenedor de combustible si está oxidado. El óxido en el combustible puede provocar problemas en el sistema de combustible. • Cubra la unidad con una cubierta protectora adecuada, resistente a la humedad. • Guarde la unidad en un área limpia y seca. • Guarde siempre el generador y el combustible lejos de fuentes de calor e ignición. NOTA: Si el combustible no se ha tratado con un estabilizador de combustible, debe drenarse en un contenedor aprobado para tal fin. Deje que el motor funcione hasta que se detenga por la falta de combustible. Para mantener el combustible en buen estado, se recomienda añadir estabilizante de combustible en el recipiente de almacenamiento. 1. Cambie el aceite del motor. 2. Quite la bujía. 3. Vierta una cucharada (5-10cc) de aceite de motor limpio o pulverice con un agente protector adecuado en el cilindro. ADVERTENCIA Pérdida de la visión. Es obligatorio llevar protección ocular para evitar las salpicaduras procedentes de la cavidad de la bujía al girar el motor. De lo contrario, se puede provocar la pérdida de la visión. (000181) 4. Tire del arranque manual varias veces para distribuir el aceite en el cilindro. 5. Vuelva a instalar la bujía. 6. Tire lentamente del arranque manual hasta sentir resistencia. Esto cerrará las válvulas para que la humedad no pueda entrar en el cilindro del motor. Suelte suavemente el arranque manual. Cambio de aceite Cambie el aceite del motor antes de guardarlo. Consulte Cambiar filtro de aceite y del aceite del motor. Preparación del sistema de combustible para su almacenamiento El combustible puede echarse a perder y dañar los componentes del sistema de combustible si se almacena durante más de 30 días. Para mantener el combustible en buen estado, utilice un estabilizante. Si se añade estabilizador de combustible al sistema de combustible, prepare y ponga en marcha el motor para su almacenamiento durante un largo período. Deje que el motor funcione durante 10-15 minutos para que el estabilizador circule por todo el sistema. El combustible preparado adecuadamente puede almacenarse hasta 24 meses. Manual del usuario del generador portátil 21 Solución de problemas PROBLEMA CAUSA SOLUCIÓN El motor funciona, pero la salida de CA no está disponible. 1. El disyuntor está ABIERTO. 2. Conexión deficiente o cable defectuoso. 3. El dispositivo conectado está averiado. 4. Fallo en el generador. 5. El módulo del disyuntor de GFCI está ABIERTO. 1. Restablezca el disyuntor. 2. Revise y repare. 3. Conecte otro dispositivo que esté en buen estado. 4. Póngase en contacto con el servicio técnico autorizado independiente. 5. Corrija el fallo del circuito de tierra y pulse el botón de reinicio en el módulo de GFCI. El motor funciona de manera correcta sin carga, pero se detiene cuando se le agrega carga. 1. Cortocircuito en una carga conectada. 2. El generador está sobrecargado. 3. La velocidad del motor es demasiado lenta. 4. Cortocircuito en el generador. 5. Filtro del combustible sucio. 6. Dispositivo antichispas bloqueado. 1. Desconecte la carga eléctrica en cortocircuito. 2. Consulte Conozca los límites del generador. 3. Póngase en contacto con el servicio técnico autorizado independiente. 4. Póngase en contacto con el servicio técnico autorizado independiente. 5. Sustituya el filtro del combustible. 6. Limpie la pantalla del supresor de chispas. El motor no arranca o arranca y funciona con dificultad. 1. La válvula de cierre de combustible está en posición OFF (APAGADO). 2. Filtro de aire sucio. 3. Sin combustible. 4. Combustible deteriorado. 5. El cable de la bujía no está conectado a la bujía. 6. Bujía averiada. 7. Agua en el combustible. 8. Exceso de cebado. 9. Nivel de aceite bajo. 10. Mezcla de combustible excesivamente rica. 11. Válvula de admisión atascada en posición abierta o cerrada. 12. El motor perdió compresión. 13. Filtro del combustible sucio. 1. Gire la válvula de cierre de combustible a la posición ON (ABIERTA). 2. Limpie o sustituya el filtro de aire. 3. Llene el depósito de combustible. 4. Vacíe el depósito de combustible y llénelo con combustible nuevo. 5. Conecte el cable a la bujía. 6. Sustituya la bujía. 7. Vacíe el depósito de combustible y llénelo con combustible nuevo. 8. Coloque la palanca del cebador a la posición sin cebado. 9. Llene el cárter hasta el nivel correcto. 10. Póngase en contacto con el servicio técnico autorizado independiente. 11. Póngase en contacto con el servicio técnico autorizado independiente. 12. Póngase en contacto con el servicio técnico autorizado independiente. 13. Sustituya el filtro del combustible. Manual del usuario del generador portátil 22 PROBLEMA CAUSA SOLUCIÓN El motor se apaga durante el funcionamiento. 1. Sin combustible. 2. Nivel de aceite bajo. 3. Fallo en el motor. 1. Llene el depósito de combustible. 2. Llene el cárter hasta el nivel correcto. 3. Póngase en contacto con el servicio técnico autorizado independiente. Falta potencia en el motor. 1. La carga es demasiado alta. 2. Filtro de aire sucio. 3. El motor necesita mantenimiento. 4. Filtro del combustible sucio. 5. Dispositivo antichispas bloqueado. 1. Reduzca la carga (consulte 1. El cebador se ha abierto demasiado pronto. 2. El carburador funciona con una mezcla demasiado rica o demasiado pobre. 1. Coloque el cebador en la posición intermedia hasta que el motor funcione suavemente. 2. Póngase en contacto con el servicio técnico autorizado independiente. El motor aumenta la tensión o se atasca. Manual del usuario del generador portátil Conozca los límites del generador). 2. Limpie o sustituya el filtro de aire. 3. Póngase en contacto con el servicio técnico autorizado independiente. 4. Sustituya el filtro del combustible. 5. Limpiar la pantalla del supresor de chispas. 23 Notas 24 Manual del usuario del generador portátil Manual del usuario del generador portátil 25 Nº de componente 10000004327 Revisión B 05/14/2018 ©2018 Generac Power Systems, Inc. Reservados todos los derechos Las especificaciones están sujetas a cambios sin previo aviso. No se permite la reproducción en ningún formato sin el consentimiento previo por escrito de Generac Power System, Inc. Generac Power Systems, Inc. S45 W29290 Hwy. 59 Waukesha, WI 53189 1-888-GENERAC (1-888-436-3722) www.generac.com/pro Générateur portatif XC Manuel du propriétaire 003436 MODÈLE : ________________________ N° DE SÉRIE : _____________________ DATE D’ACHAT : __________________ AVERTISSEMENT Danger de mort. Ce produit doit être utilisé dans une application critique de support de vie. Le non-respect de cet avertissement peut entraîner la mort ou des blessures graves. (000209b) Enregistrez votre produit Generac sur : WWW.GENERAC.COM 1-888-GENERAC (1-888-436-3722) CONSERVEZ CE MANUEL POUR RÉFÉRENCE ULTÉRIEURE Sommaire Section 1 Introduction et règles de sécurité .......................................... 1 Introduction ..................................... 1 Règles de sécurité .......................... 1 Signification des symboles de sécurité ....................................... 1 Risques associés à l’échappement et à l’emplacement .......................... 2 Risques électriques ......................... 3 Risques d'incendie .......................... 3 Levage ou suspension du générateur ....................................... 3 Index des normes ............................ 4 Section 2 Informations générales et mise en place ............................ 5 Connaître son générateur ............... 6 Émissions ........................................ 6 Fiches de raccordement .................. 7 Horomètre ....................................... 8 Retrait des pièces du colis .............. 9 Assemblage .................................... 9 Raccordement des câbles de batterie (le cas échéant) ................ 10 Ajout d’huile moteur ...................... 10 Carburant ...................................... 11 Connaître les limites de son générateur .................................... 13 Transport/Inclinaison de l’appareil ....................................... 14 Démarrage des moteurs à démarrage manuel ..................... 14 Démarrage des moteurs à démarrage électrique ................. 15 Arrêt du générateur ....................... 15 Système d’arrêt en cas de faible pression d’huile ................... 15 Section 4 Maintenance et dépannage ................................... 16 Entretien ....................................... 16 Calendrier de maintenance ........... 16 Maintenance préventive ................ 16 Maintenance du moteur ................ 17 Remplacement de la batterie (le cas échéant) ............................ 18 Inspection du silencieux et du pare-étincelles ......................... 19 Jeu de soupapes .......................... 19 Entreposage ................................. 20 Dépannage ................................... 21 Section 3 Fonctionnement ......... 12 Questions relatives au fonctionnement .............................. 12 Avant de démarrer le moteur ........ 12 Préparation du générateur à l’utilisation ................................... 12 Mise à la terre du générateur utilisé comme appareil portatif ...... 12 AVERTISSEMENT CANCER ET EFFET NOCIF SUR LA REPRODUCTION www.P65Warnings.ca.gov. (000393a) Section 1 Introduction et règles de sécurité Introduction Merci d’avoir acheté ce produit Generac Power Systems, Inc. Cet appareil a été conçu pour offrir des performances élevées pendant de nombreuses années, sous réserve d’un bon entretien. AVERTISSEMENT Consultez le manuel. Lisez complètement le manuel et assurez-vous d’en comprendre le contenu avant d’utiliser l’appareil. Une mauvaise compréhension du manuel ou de l’appareil consigne pourrait entraîner la mort ou des blessures graves. (000100a) Si vous n’avez pas la certitude d’avoir bien compris une quelconque partie de ce manuel, contactez le concessionnaire réparateur indépendant agréé (CRIA) le plus proche de chez vous, ou bien le Service client de Generac au 1-888-GENERAC (1-888-4363722) ou sur www.generac.com, qui seront ravis de vous aider. Il relève de la responsabilité du propriétaire d’utiliser et d’entretenir cet équipement de façon sûre et adéquate. Avant d’utiliser, de réparer ou d’entreposer ce générateur : • Étudiez avec attention toutes les mises en garde fournies dans ce manuel et sur les étiquettes apposées sur l’appareil. • Familiarisez-vous avec l’appareil et avec ce manuel. • Consultez les instructions relatives aux procédures d’assemblage dans la section Assemblage. Respectez strictement les instructions. Conservez ces instructions pour référence ultérieure. Fournissez SYSTÉMATIQUEMENT ce manuel à tout individu devant utiliser l’appareil. Les informations contenues dans ce manuel décrivent avec exactitude les produits fabriqués au moment de la publication du manuel. Le fabricant se réserve le droit de procéder à des mises à jour techniques, à des corrections et à des révisions des produits à tout moment et sans préavis. Règles de sécurité Le fabricant ne peut pas prévoir toutes les circonstances possibles susceptibles d’impliquer un danger. Les avertissements fournis dans ce manuel, ainsi que sur les étiquettes et autocollants apposés sur l’appareil, ne sont pas exhaustifs. Si vous recourez à une procédure, méthode de travail ou technique d’exploitation qui n’est pas spécifiquement recommandée par le fabricant, assurez-vous qu’elle est sûre pour autrui et n’entrave pas la sécurité de fonctionnement du générateur. Manuel du propriétaire de générateur portatif Tout au long de ce manuel, ainsi que sur les étiquettes et autocollants apposés sur l’appareil, des encadrés DANGER, AVERTISSEMENT, ATTENTION et REMARQUE sont utilisés pour alerter le personnel d’instructions d’utilisation spéciales dont le non-respect peut s’avérer dangereux. Respectez scrupuleusement ces instructions. La signification des différentes mentions d’alerte est la suivante : DANGER Indique une situation dangereuse qui, si elle n’est pas évitée, entraînera la mort ou des blessures graves. (000001) AVERTISSEMENT Indique une situation dangereuse qui, si elle n’est pas évitée, pourrait entraîner la mort ou des blessures graves. (000002) MISE EN GARDE Indique une situation dangereuse qui, si elle n’est pas évitée, pourrait entraîner des blessures légères ou moyennement graves. (000003) REMARQUE : Les remarques fournissent des informations complémentaires importantes sur une opération ou une procédure. Elles sont intégrées au texte ordinaire du manuel. Ces alertes de sécurité ne sauraient à elles seules éliminer les dangers qu’elles signalent. Afin d’éviter les accidents, il est fondamental de faire preuve de bon sens et de respecter strictement les instructions spéciales dans le cadre de l’utilisation et de la maintenance de l’appareil. Signification des symboles de sécurité L’utilisation d’une génératrice à l’intérieur PEUT CAUSER LA MORT EN QUELQUES MINUTES. L’échappement de la génératrice contient du monoxyde de carbone. C’est un poison qui est invisible et inodore. NE JAMAIS utiliser à l’intérieur d’une maison ou d’un garage, MÊME SI les portes ou les fenêtres sont ouvertes. Utiliser uniquement À L’EXTÉRIEUR et très loin des fenêtres, portes et évents. 000657 000657 1 DANGER AVERTISSEMENT Asphyxie. Le moteur en marche produit du monoxyde de carbone, un gaz inodore, incolore et toxique. Le monoxyde de carbone, s’il n’est pas évité, entraînera la mort ou des blessures graves. Risque de blessure. Attention à ne jamais introduire d’objets via les fentes de refroidissement. Le générateur peut démarrer à tout moment, et ainsi provoquer des blessures sérieuses, voire mortelles, et endommager considérablement l’appareil. (000142a) (000103) • Si vous commencez à vous sentir mal, ou faible, ou à avoir des vertiges après avoir fait fonctionné le générateur, sortez IMMÉDIATEMENT à l’air libre. Consultez un médecin, car il se peut que vous soyez victime d’une intoxication au monoxyde de carbone. DANGER Risques d’asphyxie. Le système d'échappement doit être correctement entretenu. N’apportez aucune modification au système d'échappement au risque de le rendre dangereux ou non conforme aux codes et/ou normes applicables au niveau local. Le non-respect de cette consigne risque d’entraîner des blessures graves, voire mortelles. (000179b) AVERTISSEMENT Risque de blessures. Il faut être parfaitement vigilant pour utiliser cet appareil et en faire l’entretien. La fatigue peut nuire à votre capacité à entretenir cet équipement et pourrait entraîner la mort ou des (000215) blessures graves. AVERTISSEMENT Blessures et dommages à l’équipement. N’utilisez pas le générateur en guise de marchepied. Ce geste pourrait entraîner votre chute, des dommages aux pièces, une utilisation non sécuritaire de l’équipement, des blessures graves, voire la mort. (000216) DANGER Décharge électrique. Le contact de l’eau avec une source d’alimentation, s’il n’est pas évité, entraînera la mort ou des blessures graves. (000104) DANGER Décharge électrique. Coupez l’alimentation du réseau public et du générateur avant de connecter les câbles d’alimentation et les lignes de charge. Le non-respect de cette consigne entraînera la mort ou des blessures graves. (000116) AVERTISSEMENT Dommages à l’équipement et aux biens. Ne modifiez pas la construction ni l’installation du générateur et ne bloquez pas la ventilation. Le non-respect de cette consigne pourrait endommager le générateur ou le rendre dangereux. 000406 • Pour des raisons de sécurité, il est recommandé de confier la maintenance de cet équipement à un CRIA. Inspectez régulièrement le générateur, et si certaines pièces nécessitent une réparation ou un remplacement, contactez le CRIA le plus proche de chez vous. (000146) AVERTISSEMENT Asphyxie. Toujours utiliser à l’intérieur une alarme à monoxyde de carbone fonctionnant sur pile, installée selon les instructions du fabricant. Sinon, cela pourrait entraîner la mort ou (000178a) des blessures graves. AVERTISSEMENT Dommages à l’équipement et aux biens. Ne faites pas fonctionner l’appareil sur des surfaces inégales ou dans des zones où il serait exposé à une humidité excessive, à de la poussière ou à des vapeurs corrosives. Le non-respect de cette consigne pourrait entraîner la mort ou des blessures graves, ainsi que des dommages aux biens et à l’équipement. (000250) AVERTISSEMENT Pièces mobiles. Gardez les vêtements, les cheveux et les accessoires loin des pièces mobiles. Le non-respect de cette consigne pourrait entraîner la mort ou des blessures graves. (000111) AVERTISSEMENT Surfaces chaudes. Lorsque vous utilisez l’appareil, ne touchez pas aux surfaces chaudes. Gardez l’appareil loin des matériaux combustibles lorsqu’il fonctionne. Le contact avec des surfaces chaudes pourrait entraîner des brûlures graves ou un incendie. (000108) 2 Risques associés à l’échappement et à l’emplacement DANGER Asphyxie. Le moteur en marche produit du monoxyde de carbone, un gaz inodore, incolore et toxique. Le monoxyde de carbone, s’il n’est pas évité, entraînera la mort ou des blessures graves. (000103) DANGER Risques d’asphyxie. Le système d'échappement doit être correctement entretenu. N’apportez aucune modification au système d'échappement au risque de le rendre dangereux ou non conforme aux codes et/ou normes applicables au niveau local. Le non-respect de cette consigne risque d’entraîner des blessures graves, voire mortelles. (000179b) AVERTISSEMENT Dommages à l’équipement et aux biens. Ne modifiez pas la construction ni l’installation du générateur et ne bloquez pas la ventilation. Le non-respect de cette consigne pourrait endommager le générateur ou le rendre dangereux. (000146) Manuel du propriétaire de générateur portatif Risques d'incendie AVERTISSEMENT Asphyxie. Toujours utiliser à l’intérieur une alarme à monoxyde de carbone fonctionnant sur pile, installée selon les instructions du fabricant. Sinon, cela pourrait entraîner la mort ou (000178a) des blessures graves. • Si vous commencez à vous sentir mal, ou affaibli, ou à avoir des vertiges après avoir fait fonctionner le générateur, sortez IMMÉDIATEMENT à l’air libre. Consultez un médecin, car il se peut que vous soyez victime d’une intoxication au monoxyde de carbone. • NE faites JAMAIS fonctionner un générateur à l'intérieur ou dans une zone partiellement fermée telle qu'un garage. • Utilisez UNIQUEMENT à l'extérieur et loin des fenêtres, des portes, des évents, des vides sanitaires et dans une zone où une ventilation adéquate est disponible et qui n'accumulera pas de gaz d'échappement mortels. • Le fait d'utiliser un ventilateur ou d'ouvrir une porte ne permet pas une ventilation suffisante. • Orientez le silencieux d’échappement à l’écart des personnes et des bâtiments occupés. Risques électriques DANGER Décharge électrique. Tout contact avec des fils nus, des bornes ou des branchements pendant que le générateur fonctionne causera la mort ou des blessures graves. (000144) DANGER Décharge électrique. Le contact de l’eau avec une source d’alimentation, s’il n’est pas évité, entraînera la mort ou des blessures graves. (000104) DANGER Décharge électrique. En cas d’accident électrique, COUPEZ immédiatement l’alimentation. Utilisez des outils non conducteurs pour libérer la victime du conducteur sous tension. Administrez-lui les premiers soins et allez chercher de l’aide médicale. Le non-respect de cette consigne entraînera la mort ou des blessures graves. (000145) AVERTISSEMENT Démarrage accidentel. Lorsque vous travaillez sur l’appareil, débranchez le câble négatif de la batterie, puis le câble positif. Le non-respect de cette consigne pourrait entraîner la mort ou des blessures graves. (000130) • Le National Electric Code (NEC) des ÉtatsUnis exige que le châssis et toutes les pièces conductrices externes du générateur soient correctement raccordés à une prise de terre approuvée. Les codes électriques locaux peuvent également exiger une mise à la terre appropriée du générateur. Consultez un électricien local pour connaître les exigences de mise à la terre propre à votre région. Manuel du propriétaire de générateur portatif DANGER Explosion et incendie. Le carburant et ses vapeurs sont extrêmement inflammables et explosifs. Ajoutez du carburant dans un endroit bien aéré. Gardez l’appareil loin du feu et des étincelles. Le non-respect de cette consigne entraînera la mort ou des blessures graves. (000105) DANGER Risque d’explosion et d’incendie. Ne remplissez jamais le réservoir de carburant de façon excessive. Laissez un espace d’un demi-pouce par rapport au haut du réservoir pour assurer la bonne expansion du carburant. Tout remplissage excessif risque de provoquer des déversements de carburant, avec un risque de formation d’incendie ou d’explosion, et de blessures sérieuses, voire mortelles. (000166b) DANGER Risque d’incendie. Laissez les déversements d’essence sécher complètement avant de démarrer le moteur. Le non-respect de cette consigne entraînera la mort ou des blessures graves. (000174) AVERTISSEMENT Risque de blessure. Attention à ne jamais introduire d’objets via les fentes de refroidissement. Le générateur peut démarrer à tout moment, et ainsi provoquer des blessures sérieuses, voire mortelles, et endommager considérablement l’appareil. (000142a) • N’utilisez en aucun cas le générateur si vous observez une surchauffe des appareils électriques qui y sont raccordés, une perte de la puissance électrique, l’apparition d’étincelles au niveau du moteur ou du générateur, ou encore de flammes ou de fumée lorsque l’équipement est en fonctionnement. • Conservez en permanence un extincteur à proximité du générateur. • Laissez un dégagement d'au moins 5 pieds de tous les côtés du générateur lors de son fonctionnement pour éviter la surchauffe et les incendies. Levage ou suspension du générateur AVERTISSEMENT Risque de blessure. Le raccordement inadéquat des câbles, chaînes ou sangles de levage peut provoquer des blessures graves, voire mortelles, ainsi que des dégâts matériels. (000346) AVERTISSEMENT Risque de blessure. L’élévation ou la suspension de l’appareil sans câbles, chaînes ou sangles capables de supporter une charge de service nominale de 2 000 lb (907 kg) minimum peut provoquer des blessures graves, voire mortelles, ainsi que des dégâts matériels. (000347) AVERTISSEMENT Risque de blessure. N’utilisez jamais le générateur en suspension. Cela peut provoquer des blessures graves, voire mortelles, ainsi que des dégâts matériels. (000348) 3 AVERTISSEMENT Risque de blessure. N’utilisez pas le crochet de levage s’il est visiblement endommagé ou corrodé. Cela peut provoquer des blessures graves, voire mortelles, ainsi que des dégâts matériels. (000349) AVERTISSEMENT Risque de blessure. N’utilisez pas le crochet de levage autrement que conformément aux instructions. Le non-respect de cette consigne peut provoquer des blessures graves, voire mortelles, ainsi que des dégâts matériels. (000350) AVERTISSEMENT Risque de blessure. Assurez-vous que toutes les fixations sont bien serrées avant de soulever l’appareil. Le non-respect de cette consigne peut provoquer des blessures graves, voire mortelles, ainsi que des dégâts matériels. (000351) Index des normes 1. National Fire Protection Association (NFPA) 70 : NATIONAL ELECTRIC CODE (NEC) des États-Unis, consultable sur www.nfpa.org 2. National Fire Protection Association (NFPA) 5000 : BUILDING CONSTRUCTION AND SAFETY CODE des États-Unis, consultable sur www.nfpa.org 3. International Building Code, consultable sur www.iccsafe.org 4. Agricultural Wiring Handbook,consultable sur www.rerc.org, ou auprès du Rural Electricity Resource Council, P.O. Box 309, Wilmington, OH 45177-0309, États-Unis 5. ASAE EP-364.2, Installation and Maintenance of Farm Standby Electric Power, consultable sur www.asabe.org, ou auprès de l’American Society of Agricultural & Biological Engineers, 2950 Niles Road, St. Joseph, MI 49085, États-Unis 6. Safety and Performance of Portable Generators, ANSI/PGMA G300, consultable sur pgmaonline.com 7. CSA C22.2 100-14 - Installation et utilisation des moteurs et générateurs électriques, conformément aux dispositions du code canadien de l’électricité Cette liste n’est pas exhaustive. Pour connaître les codes et normes locaux applicables, renseignez-vous auprès des autorités compétentes. Manuel du propriétaire de générateur portatif 4 Section 2 Informations générales et mise en place 27 23 24 25 22 20 14 28 19 26 003436 21 13 12 003441 10 15 17 14 16 18 003442 Figure2-1. Fonctions et commandes TABLEAU 1. Composants du générateur 5 1 Prise double 120 V CA, 20 A 20 Pare-étincelles 2 Prise à verrouillage 120/240 V CA, 30 A 21 Cosse de mise à la terre 3 Disjoncteurs unipolaires (CA) 4 Disjoncteurs bipolaires 22 Poignées 5 Prise à verrouillage 120 V CA, 30 A 23 Réservoir de carburant 6 Commande de ralenti 24 Bouchon d’essence 7 Module de détection de défaut de mise à la terre 25 Jauge de carburant 26 Batterie (le cas échéant) 27 Dispositif de levage en acier 28 Bouton de déverrouillage des poignées 8 Disjoncteur du module DDFT 9 Horomètre 10 Levier d’étrangleur 11 Interrupteur Démarrage/Marche/Arrêt (démarrage électrique) (6,5 kW, interrupteur Marche/Arrêt, démarrage à rappel) 12 Bougie 13 Filtre à huile 14 Tuyau de vidange d'huile 15 Bouchon de remplissage d'huile 16 Filtre à air 17 Filtre à carburant 18 Lanceur à rappel 19 Silencieux 003447 Figure2-2. Étiquette d’identification du produit Manuel du propriétaire de générateur portatif 11 3 6 1 4 5 9 2 8 7 003439 Figure2-3. Panneau de commande du générateur XC Connaître son générateur AVERTISSEMENT Consultez le manuel. Lisez complètement le manuel et assurez-vous d’en comprendre le contenu avant d’utiliser l’appareil. Une mauvaise compréhension du manuel ou de l’appareil consigne pourrait entraîner la mort ou des blessures graves. (000100a) Vous pouvez vous procurer des exemplaires de remplacement du manuel du propriétaire sur www.generac.com. Émissions L'Agence américaine de protection de l'environnement (EPA) (et le Comité des ressources de l'air de la Californie (CARB) pour les moteurs/équipements certifiés selon les normes californiennes) exige que ce(t) moteur/équipement soit conforme aux normes d'émissions d'échappement et par évaporation. Localisez l'autocollant de conformité des émissions sur le moteur afin de déterminer les normes applicables. Pour obtenir des informations sur la garantie des émissions, veuillezvous reporter à la garantie des émissions incluse. Il est important de respecter les spécifications d'entretien décrites dans le manuel afin de s'assurer que le moteur reste conforme aux normes d'émissions applicables pendant toute sa durée de vie. TABLEAU 2. Caractéristiques techniques du produit Caractéristiques techniques des générateurs de 6,5 kW / 8 kW Puissance nominale pour facteur de puissance 1,0 6,5 kW** / 8 kW** Puissance de démarrage 8,13 kW** / 10 kW** Tension CA nominale 120/240 Charge CA nominale (120 V / 240 V) 6,5 kW 8,0 kW 54,2 / 27,1 A** 66,7 / 33,3 A** Fréquence nominale 60 Hz à 3 600 tr/min Phase Monophasé Poids de l’appareil (à sec) 6,5 kW (démarrage à l'aide du lanceur à rappel uniquement) 6,5 kW (démarrage électrique) 8,0 kW (démarrage électrique) 246 lb (111,8 kg) 260 lb (117,9 kg) ** Plage de températures de fonctionnement : -18 °C (0 °F) à 40 °C (104 °F). F). Un fonctionnement à plus de 25 °C (77 °F) risquerait de réduire la puissance. ** La puissance et l’intensité maximales dépendent de, et sont limitées par, des facteurs tels que la capacité en BTU, la température ambiante, l’altitude, l’état du moteur, etc. La puissance maximale diminue d’environ 3,5 % tous les 1 000 pieds (304,8 mètres) au-dessus du niveau de la mer, et diminue d’environ 1 % tous les 6 °C (10 °F) au-dessus de 16 °C (60 °F) de température ambiante. Manuel du propriétaire de générateur portatif 6 TABLEAU 2. Caractéristiques techniques du produit Caractéristiques techniques des moteurs de 6,5 kW / 8 kW Cylindrée 426 cc Réf. des bougies 0G0767B Type de bougies Champion RC12YC ou modèle équivalent Écartement des bougies 0,02 po (0,51 mm) Contenance en essence 32 l (8,5 gal U.S.) Type d’huile Voir le tableau situé à la section Ajout d’huile moteur. Contenance en huile en changeant le filtre sans changer le filtre 1 l (1,1 pte) 0,9 l (0,95 pte) Durée de fonctionnement à charge de 50 % (6,5 kW / 8 kW) 14 heures / 11 heures * Pour obtenir des pièces de rechange, rendez-vous sur www.generac.com ou contactez un CRIA. Fiches de raccordement protégée par un disjoncteur à bascule bipolaire de 30 A. Prise double 120 V CA, 20 A La prise 120 V est protégée contre les surcharges par un disjoncteur à réarmement par bouton-poussoir de 20 A. Voir la Figure 2-4. Chaque prise alimente des charges monophasées 120 V CA, 60 Hz nécessitant un courant maximum de 2 400 W (2,4 kW) ou 20 A. Utilisez exclusivement des cordons à 3 fils de grande qualité, bien isolés, mis à la terre et d’une tension nominale de 125 V à 20 A. 000204 Figure2-5. Prise 120/240 V CA, 30 A NEMA L14-30R Prise 120 V CA, 30 A 000424 Figure2-4. Prise double 120 V CA, 20 A NEMA 5-20R Prise 120/240 V CA, 30 A Utilisez une fiche NEMA L14-30 avec cette prise (tournez pour verrouiller/déverrouiller). Raccordez un cordon à 4 fils adapté mis à la terre à la fiche et à la charge souhaitée. Le cordon doit avoir une tension nominale de 250 VCA à 30 A (ou plus). Voir la Figure 2-5. • Utilisez cette prise pour alimenter des charges monophasées de 120 VCA., 60 Hz nécessitant une puissance maximale de 3 600 W (3,6 kW) à 30 A ou des charges monophasées de 240 VCA, 60 Hz nécessitant une puissance maximale de 7 200 W (7,2 kW) à 30 A. La prise est 7 Utilisez une fiche NEMA L5-30 avec cette prise (tournez pour verrouiller/déverrouiller). Raccordez un cordon à 3 fils adapté mis à la terre à la fiche et à la charge souhaitée. Le cordon doit avoir une tension nominale de 125 V CA à 30 A (ou plus). Voir la Figure 2-6. Utilisez cette prise pour alimenter des charges monophasées de 120 V CA, 60 Hz nécessitant un courant maximum de 3 600 W (3,6 kW) à 30 A. La prise 120 V est protégée contre les surcharges par un disjoncteur à réarmement par bouton-poussoir de 30 A. 000844 Figure2-6. Prise 120 V CA, 30 A NEMA L5-30 Manuel du propriétaire de générateur portatif Horomètre L’horomètre comptabilise les heures de fonctionnement afin que l’opérateur sache quand effectuer les opérations de maintenance planifiée. Voir la Figure 2-7. • L’écran SVC s’allume une heure avant et une heure après chaque intervalle de 200 heures, laissant ainsi deux heures pour procéder à la maintenance. Lorsque l’horomètre clignote en mode d’alerte, le message relatif à la maintenance alterne avec la durée écoulée en heures et en dixièmes d’heure. Les heures clignotent quatre fois, puis le message relatif à la maintenance clignote quatre fois, et ce cycle se répète jusqu’à la réinitialisation automatique de l’horomètre. • 200 heures - SVC – Changer l’huile, le filtre à huile, le filtre à air, le filtre à carburant et la bougie. Nettoyer l’écran du pareétincelles. (Toutes les 200 heures) REMARQUE : L’icône représentant un sablier clignote lorsque le moteur fonctionne. Cela signifie que l’horomètre enregistre les heures de fonctionnement. Testez le module DDFT avant chaque utilisation. Voir la Figure 2-8. 1. Démarrez le générateur. 2. Branchez une lampe témoin à la prise double. La lampe doit s’allumer. 3. Appuyez sur le bouton TEST du DDFT pour le déclencher. Le disjoncteur principal doit se déclencher. Cela est indiqué par le passage de la poignée de l’actionneur en position ARRÊT. 4. Le flux d’électricité doit cesser et la lampe s’éteindre. Si le disjoncteur principal ne se déclenche pas, c’est que le DDFT ne fonctionne pas. Il ne faut donc pas utiliser le générateur. Contactez un CRIA. 5. Pour restaurer le flux d’électricité, placez la poignée de l’actionneur du disjoncteur en position MARCHE. La poignée doit rester verrouillée dans cette position. Dans le cas contraire, soit le DDFT soit le disjoncteur principal est défectueux. Il faut donc le remplacer. Contactez un CRIA. 6. Le DDFT est protégé contre les surcharges par un disjoncteur de 6,5 kW à 30 A ou de 8 kW à 35 A / 240 V. 7. Le DDFT est équipé de fonctions de Surveillance auto et de Fin de vue avec témoins d’état DEL. 0000.0 000205 Figure2-7. Horomètre 004285 Module de détection de défaut de mise à la terre L’appareil est équipé d’un disjoncteur différentiel de fuite à la terre (DDFT). Ce dispositif est conforme aux exigences des codes fédéraux, provinciaux et locaux. Le module de détection de défaut de mise à la terre couvre toutes les prises. En cas de défaut de mise à la terre, le DDFT se déclenche et coupe le flux d'électricité pour empêcher de graves blessures. Le DDFT surveille constamment le flux d’électricité à l’intérieur d’un circuit. Si le courant traversant un circuit est différent du courant de retour, le DDFT coupe l’alimentation en déclenchant de disjoncteur principal situé sur le panneau de commande du générateur. Un DDFT n’assure AUCUNE protection contre les surcharges, courts-circuits ou chocs électriques. Un choc électrique peut survenir si une personne touche des fils électriques chargés alors qu’elle se trouve sur une surface non conductrice, telle qu’un plancher en bois. Manuel du propriétaire de générateur portatif Figure2-8. Test du DDFT Commande de ralenti automatique (le cas échéant) Cette fonction optimise les économies de carburant. Lorsque cet interrupteur est en position MARCHE, le moteur tourne à une vitesse régulée rapide normale lorsqu’une charge électrique est connectée. Si la charge est retirée, le moteur tourne à vitesse réduite. Lorsque l’interrupteur est en position ARRÊT, le moteur tourne en continu à vitesse rapide normale. Assurez-vous systématiquement que l’interrupteur en en position ARRÊT lorsque vous démarrez et arrêtez le moteur. Voir la Figure 2-8. 8 Retrait des pièces du colis 1. Ouvrez complètement le carton en découpant chaque coin de haut en bas. 2. Retirez les pièces du carton et inspectezles avant de procéder à l’assemblage. Le colis doit contenir les pièces suivantes : TABLEAU 3. Accessoires Article Qté Unité principale 1 Manuel du propriétaire 1 Manuel du moteur 1 Bidon d’huile SAE de 1 pinte 1 Filtre à huile 1 Filtre à air 1 Bougie 1 Clé à bougies 1 Chiffon 1 Couvercles supérieurs (8) 2 Roues (1) 2 Pieds du châssis (2) 2 Dispositif de levage en acier (3) 2 Pour installer les accessoires, vous aurez besoin des outils suivants : • Tournevis (1) • Clés de 8 mm (2) • Clés de 13 mm (2) Voir la Figure 2-9. Installez le dispositif de levage comme suit : 1. Installez chaque moitié du dispositif de levage (3) sous le châssis et placez sans trop les serrer les boulons de 45 mm (7) et les écrous (11) dans les trous prévus à cet effet sur le châssis. 2. Placez les boulons de 20 mm (10) et les écrous (11) dans les trous prévus à cet effet sur les moitiés du dispositif de levage. 3. Serrez bien tous les boulons. 4. Alignez chaque couvercle supérieur (8) avec les trous prévus à cet effet sur le dispositif de levage inférieur. Insérez le corps de la borne de raccordement (9) et fixez-le avec une vis de borne de raccordement (9). 7 11 10 9 Sachet de pièces de quincaillerie Qté 9 8 Épingles (4) 2 Axe (5) 1 Rondelles plates 5/8" (6) 2 Boulons de 45 mm (7) 8 Bornes de raccordement (9) 2 Boulons de 20 mm (10) 2 Figure2-9. Assemblage du dispositif de levage en acier Écrous (11) 6 REMARQUE : Les roues ne sont pas destinées à un usage sur route. Voir la Figure 2-10. Installez les roues comme suit : 1. Faites glisser l’axe (5) dans les trous prévus à cet effet sur le châssis du générateur. 2. Faites glisser la roue (1) et une rondelle de 5/8" (6) sur l’axe. 3. Fixez l’ensemble à l’aide d’une épingle (4). Renouvelez l’opération de l’autre côté du générateur. Installez les pieds comme suit : 1. Alignez le pied (2) avec les trous prévus à cet effet sur le châssis et fixez-le avec des boulons de 45 mm (7). 3. Si certaines pièces sont absentes du colis, contactez le Service client de Generac au 1-888-GENERAC (1-888-436-3722) en vous munissant du nom du modèle et du numéro de série de l’appareil. 4. Consignez le nom du modèle, le numéro de série et la date d’achat sur la page de garde de ce manuel. Assemblage AVERTISSEMENT Consultez le manuel. Lisez complètement le manuel et assurez-vous d’en comprendre le contenu avant d’utiliser l’appareil. Une mauvaise compréhension du manuel ou de l’appareil consigne pourrait entraîner la mort ou des blessures graves. (000100a) 3 11 003759 Si vous rencontrez des problèmes lors de l’assemblage, contactez le Service client de Generac au 1-888-GENERAC (1-888-4363722). Veillez à vous munir du nom du modèle et du numéro de série. 9 Manuel du propriétaire de générateur portatif 3 5 1 6 2 7 4 003448 Figure2-10. Assemblage des roues et des pieds Raccordement des câbles de batterie (le cas échéant) MISE EN GARDE Risque de dégâts matériels. Ne raccordez pas la batterie dans le mauvais sens. L’équipement pourrait s’endommager. (000167a) L’appareil est expédié avec les câbles de batterie débranchés. Pour les brancher, vous aurez besoin de deux clés polygonales de 8 mm. Voir la Figure 4-5. 1. Coupez les attaches de câble retenant les câbles de batterie et retirez le couvercle rouge des bornes de la batterie. 2. Commencez par brancher les câbles rouges à la borne positive (+) de la batterie à l’aide du boulon et de l’écrou fournis. 3. Assurez-vous que les raccords sont bien fixés et faites glisser la gaine en caoutchouc par-dessus la borne positive (+) de la batterie et les fixations. 4. Branchez ensuite les câbles noirs à la borne négative (-) de la batterie à l’aide du boulon et de l’écrou fournis. Faites glisser la gaine en caoutchouc pardessus la borne négative (+) de la batterie et les fixations. 5. Assurez-vous que tous les raccords sont bien fixés. REMARQUE : Si la batterie ne parvient pas à démarrer le moteur, chargez-la à l’aide d’un chargeur approprié de 12 V ou démarrez manuellement le générateur et laissez tourner jusqu’à charge complète. Manuel du propriétaire de générateur portatif Ajout d’huile moteur MISE EN GARDE Dommages au moteur. Vérifiez que le type et la quantité de l’huile à moteur sont adéquats avant de démarrer le moteur. Le non-respect de cette consigne pourrait causer des dommages au moteur. (000135) 1. Placez le générateur sur une surface de niveau. 2. Vérifiez que la zone de remplissage d’huile est propre. 3. Retirez le bouchon de remplissage d’huile et essuyez la jauge. Voir la Figure 2-11. 000115 Figure2-11. Retrait de la jauge 4. Ajoutez l’huile moteur recommandée. La viscosité appropriée de l’huile est déterminée en fonction du climat. Consultez le tableau pour sélectionner la bonne viscosité. REMARQUE : Utilisez de l’huile à base de pétrole (fournie) pendant le rodage, puis de l’huile synthétique par la suite. 10 . SAE 30 10W-30 5W-30 synthétique °F °C Plage de température de l’utilisation prévue 000399 REMARQUE : Certains appareils possèdent plusieurs orifices de remplissage d’huile. Il n’est pas nécessaire d’utiliser plus d’un point de remplissage. 5. Vissez la jauge dans le col de remplissage d’huile. Contrôlez le niveau d’huile une fois la jauge bien en place au fond du réservoir. 6. Voir la Figure 2-12. Retirez la jauge et vérifiez que le niveau d’huile se situe dans la plage permettant un fonctionnement sûr. • N’UTILISEZ PAS de mélange d’huile et d’essence. • NE MODIFIEZ PAS le moteur pour le faire fonctionner avec d’autres carburants. Stabilisez le niveau de carburant avant d’entreposer le générateur. 1. Vérifiez que l’appareil est en position ARRÊT et laissez-le refroidir pendant au moins deux minutes avant de faire le plein de carburant. 2. Placez l’appareil de niveau dans une zone bien ventilée. 3. Nettoyez la zone environnant le bouchon de carburant et retirez-le lentement. 4. Ajoutez lentement le carburant recommandé. Ne remplissez pas le réservoir au-dessus de la lèvre intérieure. Voir la Figure 2-13. 5. Remettez le bouchon de remplissage d'huile en place. A 000230 Figure2-13. Ajout du carburant recommandé 003620 Figure2-12. Plage de fonctionnement sûr 7. Placez le bouchon de remplissage d’huile / la jauge et serrez manuellement. Carburant DANGER Explosion et incendie. Le carburant et ses vapeurs sont extrêmement inflammables et explosifs. Ajoutez du carburant dans un endroit bien aéré. Gardez l’appareil loin du feu et des étincelles. Le non-respect de cette consigne entraînera la mort ou des blessures graves. (000105) DANGER Risque d’explosion et d’incendie. Ne remplissez jamais le réservoir de carburant de façon excessive. Laissez un espace d’un demi-pouce par rapport au haut du réservoir pour assurer la bonne expansion du carburant. Tout remplissage excessif risque de provoquer des déversements de carburant, avec un risque de formation d’incendie ou d’explosion, et de blessures sérieuses, voire mortelles. (000166b) Les spécifications relatives au carburant sont les suivantes : • Essence propre sans plomb. • Indice d’octane minimum de 87 / 87 AKI (91 RON). • Teneur en éthanol (essence-alcool) admissible jusqu’à 10 % (lorsque possible, un carburant premium sans éthanol est recommandé). • N’UTILISEZ PAS de carburant E85. 11 REMARQUE : Laissez le carburant déversé hors du réservoir s’évaporer avant de démarrer l’appareil. REMARQUE IMPORTANTE : Il est important d’empêcher la formation de dépôts de gomme dans les pièces du circuit de carburant telles que le carburateur, le tuyau de carburant et le réservoir durant l'entreposage. Les carburants à base d’alcool (appelés essence-alcool, éthanol ou méthanol) peuvent attirer l’humidité, ce qui entraîne une séparation et la formation d’acides durant l’entreposage. Les gaz acides peuvent endommager le circuit de carburant d’un moteur entreposé. Afin d’éviter tout problème de moteur, le circuit de carburant doit être vidé avant tout entreposage de plus de 30 jours. Voir la section Entreposage. N’utilisez jamais de produits nettoyants pour moteur ou carburateur dans le réservoir de carburant; cela risquerait de causer des dommages permanents. Manuel du propriétaire de générateur portatif Section 3 Fonctionnement Questions relatives au fonctionnement MISE EN GARDE Si vous avez des questions concernant l’utilisation et l’entretien de l’équipement, contactez le Service client de Generac au 1-888-GENERAC (1-888-436-3722). Avant de démarrer le moteur 1. Vérifiez que le niveau d’huile moteur est correct. 2. Vérifiez que le niveau de carburant est correct. 3. Vérifiez que l’appareil est installé de niveau, en extérieur, dans une zone bien ventilée, et que l’accès à l’appareil est dégagé. Préparation du générateur à l’utilisation DANGER Asphyxie. Le moteur en marche produit du monoxyde de carbone, un gaz inodore, incolore et toxique. Le monoxyde de carbone, s’il n’est pas évité, entraînera la mort ou des blessures graves. (000103) DANGER Risques d’asphyxie. Le système d'échappement doit être correctement entretenu. N’apportez aucune modification au système d'échappement au risque de le rendre dangereux ou non conforme aux codes et/ou normes applicables au niveau local. Le non-respect de cette consigne risque d’entraîner des blessures graves, voire mortelles. (000179b) Dommages à l’équipement et aux biens. Débranchez les charges électriques avant de démarrer ou d’arrêter l’appareil. Le non-respect de cette consigne pourrait causer des dommages à l’équipement et aux biens. (000136) Mise à la terre du générateur utilisé comme appareil portatif Le générateur est équipé d’une borne permettant le raccordement d’un système d’électrodes de mise à la terre. L’article 250.34 (A) du NEC ne requiert pas la connexion du châssis à un système d’électrodes de mise à la terre lorsque le générateur alimente uniquement des équipements raccordés à ses prises par un système de cordon et fiche. En revanche, si le générateur alimente un interrupteur de transfert manuel tripolaire ou des tableaux de distribution pour assurer une alimentation temporaire, un système d’électrodes de mise à la terre doit être installé et raccordé à la borne d’électrodes de mise à la terre du générateur. Voir les articles 250.30, 250.34 et 250.52 du NEC pour clarification. Voir la Figure 3-1. • Neutre raccordé au châssis AVERTISSEMENT Risque d’incendie. N’utilisez pas le générateur sans le pare-étincelles. Le non-respect de cette consigne pourrait entraîner la mort ou des blessures graves. (000118a) AVERTISSEMENT Asphyxie. Toujours utiliser à l’intérieur une alarme à monoxyde de carbone fonctionnant sur pile, installée selon les instructions du fabricant. Sinon, cela pourrait entraîner la mort ou (000178a) des blessures graves. AVERTISSEMENT Risque d’incendie. Les surfaces chaudes peuvent enflammer des matériaux combustibles, ce qui pourrait causer un incendie. Un incendie pourrait entraîner la mort ou des blessures graves. (000110) AVERTISSEMENT Surfaces chaudes. Lorsque vous utilisez l’appareil, ne touchez pas aux surfaces chaudes. Gardez l’appareil loin des matériaux combustibles lorsqu’il fonctionne. Le contact avec des surfaces chaudes pourrait entraîner des brûlures graves ou un incendie. (000108) Manuel du propriétaire de générateur portatif 000227 Figure3-1.Mise à la terre du générateur Exigences spéciales Passez en revue toutes les réglementations de fédérales et d'état de l’Occupational Safety and Health Administration (OSHA), ainsi que tous les codes et ordonnances applicables à l’usage prévu du générateur. Des règlementations supplémentaires sont applicables si le générateur est utilisé sur un chantier de construction. Consultez un électricien qualifié, un inspecteur en électricité ou l'organisme local compétent pour connaître les exigences supplémentaires qui peuvent être propres à votre région, comme par exemple l'obligation d'enregistrer le générateur auprès des services publics locaux. 12 Raccordement du générateur au réseau électrique d’un bâtiment Il est recommandé d'utiliser un commutateur de transfert manuel pour le branchement direct à un circuit électrique du bâtiment. Le raccordement d'un générateur portatif à un circuit électrique de bâtiment doit être effectué par un électricien qualifié en stricte conformité avec tous les codes et lois électriques nationaux et locaux. 2. Ajoutez à ce chiffre la puissance nécessaire au fonctionnement de toutes les autres charges connectées. Le Guide de référence de la puissance requise vous aide à déterminer le nombre d’appareils que le générateur peut alimenter simultanément. REMARQUE : Tous les chiffres fournis sont approximatifs. Pour connaître la puissance requise par un appareil, consultez l’étiquette apposée sur celui-ci. Raccordement de charges électriques Tableau 3. Guide de référence de la puissance requise Ne raccordez JAMAIS de charges de 240 V à des prises de 120 V. Ne raccordez JAMAIS de charges triphasées au générateur. Ne raccordez JAMAIS de charges de 50 Hz au générateur. Laissez le moteur se stabiliser et chauffer pendant quelques minutes après le démarrage. Branchez et allumez les charges électriques monophasées de 120 ou 240 V CA, 60 Hz souhaitées. Additionnez les puissances (ou intensités) nominales respectives de toutes les charges à connecter simultanément. Le total ne doit pas être supérieur à (a) la puissance / l’intensité nominale du générateur ou (b) la capacité nominale du disjoncteur de la prise d’alimentation. Voir la section Connaître les limites de son générateur. Appareil Puissance de fonctionnement *Climatiseur (12 000 BTU) 1 700 *Climatiseur (24 000 BTU) 3 800 *Climatiseur (40 000 BTU) 6 000 Chargeur de batterie (20 A) Ponceuse à courroie (3") Scie à chaîne Scie circulaire (6-1/2") *Sécheuse à linge (électrique) *Sécheuse à linge (au gaz) 500 1 000 1 200 800 à 1 000 5 750 700 *Laveuse à linge 1 150 Cafetière 1 750 *Compresseur (1 HP) 2 000 Connaître les limites de son générateur *Compresseur (3/4 HP) 1 800 *Compresseur (1/2 HP) 1 400 Une surcharge peut endommager le générateur et les appareils électriques connectés à celui-ci. Pour éviter toute surcharge, respectez les consignes suivantes : • Additionnez les puissances respectives de tous les appareils électriques à connecter simultanément. Ce total ne doit JAMAIS être supérieur à la puissance nominale du générateur. • La puissance nominale des ampoules est indiquée sur celles-ci. La puissance nominale des outils, appareils et moteurs est indiquée sur une étiquette ou un autocollant apposé sur ceux-ci. • Si la puissance d’un outil, appareil ou moteur n’est pas indiquée, multipliez la tension par l’intensité pour la déterminer (tension x intensité = puissance). • Certains moteurs électriques, notamment ceux à induction, nécessitent environ trois fois plus de puissance pour démarrer que pour tourner. Cette saute de puissance ne dure que quelques secondes au démarrage du moteur. Assurez-vous de la disponibilité d’une puissance de démarrage élevée lors de la sélection des appareils à connecter au générateur : 1. Déterminez la puissance nécessaire au démarrage du plus gros moteur. Fer à friser 700 *Déshumidificateur 650 13 Ponceuse à disque (9") Coupe-bordures Couverture chauffante 1 200 500 400 Cloueuse électrique 1 200 Cuisinière électrique (par élément) 1 500 Poêle à frire électrique 1 250 *Congélateur 700 *Ventilateur de chaudière (3/5 HP) 875 Ouvre-porte de garage Sèche-cheveux Perceuse à main Taille-haie Clé à chocs Fer à repasser *Pompe à jet Tondeuse à gazon Ampoule 500 à 750 1 200 250 à 1 100 450 500 1 200 800 1 200 100 Four à micro-ondes 700 à 1 000 *Refroidisseur de lait 1 100 Manuel du propriétaire de générateur portatif Brûleur à mazout de chaudière 300 Radiateur à mazout (140 000 BTU) 400 Radiateur à mazout (85 000 BTU) 225 Radiateur à mazout (30 000 BTU) 150 *Pistolet à peinture sans air (1/3 HP) 600 Pistolet à peinture sans air (portatif) 150 Radio 50 à 200 *Réfrigérateur Mijoteuse C A . 5. Faites glisser le levier d’étrangleur (B) en position ÉTRANGLEMENT MAX (gauche). Voir la Figure 3-2. 6. Voir la Figure 3-2. Saisissez fermement la poignée du lanceur à rappel (C) et tirez lentement jusqu’à ressentir une résistance accrue. Tirez rapidement vers le haut et vers l’extérieur. 7. Lorsque le moteur démarre, placez le levier d’étrangleur en position 1/2 ÉTRANGLEMENT jusqu’à ce que le moteur tourne sans à-coups, puis en position complètement OUVERTE (droite). Si le moteur hésite, replacez le levier d’étrangleur en position 1/2 ÉTRANGLEMENT jusqu’à ce que le moteur tourne sans à-coups, puis en position OUVERTE (droite). REMARQUE : Si le moteur se lance, mais ne continue pas à tourner, placez le levier d’étrangleur en position ÉTRANGLEMENT MAX (gauche), puis renouvelez la procédure de démarrage. REMARQUE IMPORTANTE : Ne surchargez pas les prises du générateur ou des panneaux individuels. Ces prises sont protégées contre les surcharges par des disjoncteurs à réarmement par boutonpoussoir. En cas de dépassement de l’intensité nominale de l’un des disjoncteurs, celui-ci s’ouvre pour couper l’alimentation électrique de la prise associée. Lisez attentivement la section Connaître les limites de son générateur. 2 000 1 500 800 à 1 050 1 750 à 2 000 Téléviseur 200 à 500 Grille-pain 1 000 à 1 650 Coupe-herbe 003449 B 200 *Pompe immergée (1 HP) *Scie circulaire à table (10") ARRÊT Figure3-2.Commandes du moteur 2 800 *Pompe de vidange MARCHE 700 *Pompe immergée (1-1/2 HP) *Pompe immergée (1/2 HP) FERMÉ 500 * Prévoyez 3 fois la puissance indiquée pour le démarrage de ces appareils. Transport/Inclinaison de l’appareil N’entreposez pas et ne transportez pas l’appareil incliné à un angle de plus de 15°. Démarrage des moteurs à démarrage manuel AVERTISSEMENT Risque lié au lanceur à rappel. Le cordon du lanceur à rappel pourrait se rétracter de façon inattendue. Un effet de rebond pourrait entraîner la mort ou des blessures graves. (000183) MISE EN GARDE Dommages à l’équipement et aux biens. Débranchez les charges électriques avant de démarrer ou d’arrêter l’appareil. Le non-respect de cette consigne pourrait causer des dommages à l’équipement et aux biens. (000136) 1. Avant de démarrer le moteur, débranchez toutes les charges électriques des prises de l’appareil. 2. Placez le générateur sur une surface de niveau. 3. Tournez le robinet d’arrêt de carburant (A) en sens antihoraire pour le placer en position ARRÊT (ouverte). Voir la Figure 3-2. 4. Tounez l’interrupteur de MARCHE/ARRÊT en position MARCHE. Voir le Tableau 1 : Composants du générateur. Manuel du propriétaire de générateur portatif 14 Démarrage des moteurs à démarrage électrique MISE EN GARDE Dommages à l’équipement et aux biens. Débranchez les charges électriques avant de démarrer ou d’arrêter l’appareil. Le non-respect de cette consigne pourrait causer des dommages à l’équipement et aux biens. (000136) 1. Avant de démarrer le moteur, débranchez toutes les charges électriques des prises de l’appareil. 2. Placez le générateur sur une surface de niveau. 3. Tournez le robinet d’arrêt de carburant (A) en sens antihoraire pour le placer en position MARCHE (ouverte). Voir la Figure 3-2. 4. Faites glisser le levier d’étrangleur (B) en position ÉTRANGLEMENT MAX (gauche). Voir la Figure 3-2. 5. Tournez et maintenez l’interrupteur DÉMARRAGE/MARCHE/ARRÊT en position DÉMARRAGE. Au démarrage du moteur, relâchez l’interrupteur en position MARCHE. 6. Lorsque le moteur démarre, placez le levier d’étrangleur en position 1/2 ÉTRANGLEMENT jusqu’à ce que le moteur tourne sans à-coups, puis en position complètement OUVERTE (droite). Si le moteur hésite, replacez le levier d’étrangleur en position 1/2 ÉTRANGLEMENT jusqu’à ce que le moteur tourne sans à-coups, puis en position OUVERTE (droite). REMARQUE : Si le moteur se lance, mais ne continue pas à tourner, placez le levier d’étrangleur en position ÉTRANGLEMENT MAX (gauche), puis renouvelez la procédure de démarrage. 15 Arrêt du générateur MISE EN GARDE Dommages à l’équipement et aux biens. Débranchez les charges électriques avant de démarrer ou d’arrêter l’appareil. Le non-respect de cette consigne pourrait causer des dommages à l’équipement et aux biens. (000136) 1. Arrêtez toutes les charges et débranchezles des prises du panneau du générateur. 2. Laissez le moteur tourner sans charges pendant quelques minutes pour stabiliser les températures internes du moteur et du générateur. 3. Placez l’interrupteur DÉMARRAGE/ MARCHE/ARRÊT en position ARRÊT. 4. Tournez le robinet d’arrêt de carburant en sens horaire pour le placer en position MARCHE (fermée). REMARQUE : En conditions normales, fermez le robinet de carburant et laissez le générateur faire tourner la cuve du carburateur sans carburant. En cas d’urgence, placez l’interrupteur sur ARRÊT. Système d’arrêt en cas de faible pression d’huile Le moteur est équipé d’un capteur de faible pression d’huile qui arrête automatiquement le moteur lorsque la pression d’huile chute en dessous de la limite spécifiée. Le moteur ne tournera pas tant que le réservoir d’huile n’aura pas été rempli à un niveau approprié. Si le moteur s’arrête alors que la quantité de carburant est suffisante, contrôlez le niveau d’huile moteur. Manuel du propriétaire de générateur portatif Section 4 Maintenance et dépannage Entretien Un entretien régulier permet d'améliorer les performances et de prolonger la durée de vie du moteur/de l'équipement. Generac Power Systems, Inc. préconise que tous les travaux d'entretien soient menés par un fournisseur de services d'entretien agréé. Pour l'entretien régulier, le remplacement ou la réparation des appareils et des systèmes de contrôle des émissions, le propriétaire peut faire appel à la personne ou à l'atelier de réparation de son choix. Toutefois, pour obtenir un service de garantie relatif au contrôle des émissions sans frais, cette tâche doit être confiée à un fournisseur de services d'entretien agréé. Consultez la garantie en matière d'émissions. REMARQUE : Pour toute question relative au remplacement des composants, contactez le Service client de Generac au 1-888GENERAC (1-888-436-3722). Calendrier de maintenance Respectez les intervalles de maintenance, en tenant toujours compte de la première occurrence selon l’utilisation. REMARQUE : Des conditions difficiles imposent des opérations de maintenance plus fréquentes. REMARQUE : Pour obtenir des pièces de rechange, rendez-vous sur www.generac.com ou contactez un CRIA. REMARQUE : Les différents réglages et réparations requis doivent être effectués chaque saison comme détaillé dans le tableau suivant. À chaque utilisation Contrôle du niveau d’huile Toutes les 100 heures ou chaque saison* Nettoyage de l’écran du pare-étincelles Chaque saison Contrôle du jeu de soupapes*** Toutes les 200 heures ou chaque saison Remplacement de l’huile Ƅ Remplacement de la bougie Remplacement du filtre à carburant Inspection/Nettoyage du filtre à air** Manuel du propriétaire de générateur portatif Ƅ Remplacez l’huile au bout des 25 premières heures de fonctionnement, puis chaque saison par la suite. *Remplacez l’huile et le filtre à huile chaque mois en cas de charge lourde ou de températures élevées. **Nettoyez le filtre à air plus souvent en cas d’environnement sale ou poussiéreux. Si les pièces du filtre à air ne peuvent pas être nettoyées correctement, remplacez-les. ***Contrôlez le jeu de soupapes et ajustez-le si nécessaire après les 50 premières heures de fonctionnement, puis toutes les 400 heures par la suite. Maintenance préventive Des saletés ou des débris peuvent provoquer des dysfonctionnements et endommager l’équipement. Nettoyez le générateur quotidiennement ou avant chaque utilisation. Maintenez la zone environnant le silencieux libre de tout débris combustible. Inspectez toutes les fentes de refroidissement du générateur. AVERTISSEMENT Risque de blessure. Attention à ne jamais introduire d’objets via les fentes de refroidissement. Le générateur peut démarrer à tout moment, et ainsi provoquer des blessures sérieuses, voire mortelles, et endommager considérablement l’appareil. (000142a) • Nettoyez les surfaces externes à l’aide d’un chiffon humide. • Éliminez la crasse, les résidus d’huile, etc., à l’aide d’une brosse douce. • Éliminez les saletés et les débris à l’aide d’un aspirateur. • Vous pouvez utiliser de l’air à basse pression (25 psi max.) pour souffler les saletés. Inspectez toutes les fentes de refroidissement du générateur. Ces fentes doivent rester propres et dégagées. REMARQUE : N’utilisez JAMAIS un boyau d’arrosage pour nettoyer le générateur. De l’eau risquerait de pénétrer dans le circuit de carburant du moteur, provoquant ainsi des dysfonctionnements. En cas de pénétration d’eau dans le générateur par les fentes de refroidissement, une partie de cette eau se loge dans les creux et crevasses du rotor ainsi que dans l’isolation des enroulements du stator. L’accumulation d’eau et de saletés au niveau des enroulements internes du générateur peut réduire la résistance d’isolement des enroulements. 16 Maintenance du moteur AVERTISSEMENT Démarrage accidentel. Débranchez les câbles de bougie lorsque vous travaillez sur l’appareil. Le non-respect de cette consigne pourrait entraîner la mort ou des blessures graves. 4. Vissez la jauge dans le col de remplissage d’huile. Retirez la jauge et vérifiez que le niveau d’huile se situe dans la plage permettant un fonctionnement sûr. Voir la Figure 4-2. (000141) Recommandations relatives à l'huile moteur Afin que la garantie du produit reste en vigueur, l’entretien de l’huile à moteur doit être fait conformément aux recommandations du présent manuel. Pour un entretien facile, des trousses d’entretien conçues pour cet appareil sont offertes par le fabricant. Elles comprennent de l’huile à moteur, un filtre à huile, un filtre à air, des bougies d’allumage, un chiffon et un entonnoir. Ces trousses sont disponibles auprès d’un fournisseur indépendant de services d’entretien agréé. SAE 30 003620 Figure 4-2. Plage de fonctionnement sûr 5. Ajoutez la quantité requise d’huile moteur recommandée. 6. Replacez le bouchon de remplissage d’huile et serrez-le manuellement. REMARQUE : Certains appareils possèdent plusieurs orifices de remplissage d’huile. Il n’est pas nécessaire d’utiliser plus d’un point de remplissage. 10W-30 Remplacement de l'huile moteur et du filtre à huile 5W-30 synthétique °F AVERTISSEMENT °C Plage de température de l’utilisation prévue 000399 . Démarrage accidentel. Débranchez les câbles de bougie lorsque vous travaillez sur l’appareil. Le non-respect de cette consigne pourrait entraîner la mort ou des blessures graves. (000141) Inspection du niveau d’huile moteur AVERTISSEMENT AVERTISSEMENT Risque de brûlures. Laissez refroidir le moteur avant de vidanger l’huile ou le liquide de refroidissement. Le non-respect de cette consigne pourrait entraîner la mort ou des blessures graves. (000139) Inspectez le niveau d’huile moteur avant chaque utilisation ou toutes les 8 heures de fonctionnement. 1. Placez le générateur sur une surface de niveau. 2. Nettoyez la zone de remplissage d’huile. 3. Voir la Figure 4-1. Retirez le bouchon de remplissage d’huile et essuyez la jauge. 000115 Risque de brûlures. Laissez refroidir le moteur avant de vidanger l’huile ou le liquide de refroidissement. Le non-respect de cette consigne pourrait entraîner la mort ou des blessures graves. (000139) Si vous utilisez le générateur dans un environnement extrêmement difficile, sale, poussiéreux ou chaud, remplacez l’huile plus fréquemment. REMARQUE : Ne polluez pas. Conservez les ressources. Jetez l’huile usée dans un centre de collecte des déchets approprié. Remplacez l’huile lorsque le moteur est froid, en procédant comme suit : 1. Placez le générateur sur une surface de niveau. 2. Débranchez le fil de la bougie et placez-le à l’écart de celle-ci pour éviter tout contact. 3. Nettoyez la zone de remplissage d’huile et le bouchon de vidange d’huile. 4. Retirez le bouchon de remplissage d’huile. 5. Retirez le bouchon du tuyau de vidange d’huile et purgez la totalité de l’huile dans un conteneur adapté. Figure 4-1. Plein d’huile moteur 17 Manuel du propriétaire de générateur portatif 6. Replacez le bouchon du tuyau de vidange d’huile et serrez-le fermement. 7. Placez un conteneur adapté sous le filtre à huile et tournez le filtre en sens antihoraire pour le retirer. Jetez-le conformément aux réglementations locales. 8. Appliquez un léger revêtement d’huile moteur propre sur le joint du filtre neuf. Tournez le filtre en sens horaire jusqu’à ce que le joint soit juste en contact avec l’adaptateur. Serrez ensuite le filtre de 3/4 de tour supplémentaires. 9. Versez lentement l’huile dans l’orifice de remplissage jusqu’à ce que le niveau d’huile se situe dans la plage de fonctionnement sûr. NE REMPLISSEZ PAS LE RÉSERVOIR D’HUILE DE FAÇON EXCESSIVE. 10. Replacez le bouchon de remplissage d’huile et serrez-le manuellement. 11. Essuyez toute huile déversée hors du réservoir. 12. Jetez l’huile conformément à toutes les réglementations applicables. Filtre à air Si le filtre à air est sale, le moteur ne fonctionne pas correctement et risque d’être endommagé. Effectuez la maintenance du filtre à air plus souvent en cas d’environnement sale ou poussiéreux. Pour procéder à la maintenance du filtre à air : 1. Voir la Figure 4-3. Retirez le couvercle (A) du filtre à air et le filtre à air (B). 2. Tapotez délicatement le filtre contre une surface solide. Si le filtre est trop sale, remplacez-le. 3. Nettoyez le couvercle du filtre à air avant de le remettre en place. REMARQUE : Pour commander un filtre à air neuf, contactez le CRIA le plus proche de chez vous ou le Service client de Generac au 1-888-GENERAC (1-888-436-3722). B Entretien de la bougie Pour effectuer la maintenance de la bougie : 1. Nettoyez soigneusement la zone environnant la bougie. 2. Retirez et inspectez la bougie. 3. Inspectez l’écartement des électrodes à l’aide d’une jauge à fils et réajustez-le si nécessaire à 0,02 po (0,51 mm). Voir la Figure 4-4. 000211 Figure 4-4. Bougie REMARQUE : Ne remplacez la bougie que si les électrodes sont trouées ou brûlées, ou si la porcelaine est fissurée. Utilisez EXCLUSIVEMENT la bougie de rechange recommandée. Voir les Caractéristiques techniques. 4. Installez la bougie en la serrant manuellement, puis serrez de 3/8 à 1/2 tour à l’aide d’une clé à bougies. Remplacement de la batterie (le cas échéant) REMARQUE : L’appareil est expédié avec la batterie complètement chargée. Si elle n'est pas utilisée pendant une période prolongée, une batterie peut se décharger partiellement. Il peut être nécessaire de charger la batterie avant la première utilisation. Pour ce faire, il suffit de faire fonctionner le générateur. AVERTISSEMENT Démarrage accidentel. Lorsque vous travaillez sur l’appareil, débranchez le câble négatif de la batterie, puis le câble positif. Le non-respect de cette consigne pourrait entraîner la mort ou des blessures graves. (000130) A 003466 Figure 4-3. Filtre à air Manuel du propriétaire de générateur portatif Voir la Figure 4-5. 1. Débranchez les fixations (8 mm) et le fil NOIR (B) de la borne NÉGATIVE (-) de la batterie. 2. Retirez la gaine en caoutchouc rouge (A) et débranchez les fixations (8 mm) et le fil ROUGE (C) de la borne POSITIVE (+) de la batterie. 3. Installez la batterie neuve. Fixez la batterie à l’aide de la sangle prévue à cet effet. 4. Raccordez le fil ROUGE à la borne POSITIVE (+) de la batterie (C). Faites glisser la gaine en caoutchouc (A) par-dessus les fixations. 5. Raccordez le fil NOIR à la borne NÉGATIVE (-) de la batterie (B). 18 Inspection de l’écran du pare-étincelles A AVERTISSEMENT Surfaces chaudes. Lorsque vous utilisez l’appareil, ne touchez pas aux surfaces chaudes. Gardez l’appareil loin des matériaux combustibles lorsqu’il fonctionne. Le contact avec des surfaces chaudes pourrait entraîner des brûlures graves ou un incendie. (000108) B C 003760 Figure 4-5. Raccordement de la batterie AVERTISSEMENT Risque environnemental. Recyclez toujours les batteries dans un centre de recyclage officiel, conformément aux lois et aux réglementations locales. Le non-respect de cette consigne pourrait causer des dommages à l’environnement, (000228) la mort ou des blessures graves. Inspection du silencieux et du pare-étincelles REMARQUE : L’utilisation du moteur sur un terrain recouvert de forêt, de broussailles ou d’herbe constitue une violation de l’Article 4442 du California Public Resource Code, à moins que le système d’échappement ne soit équipé d’un pare-étincelles entretenu en bon état de fonctionnement, comme défini dans ledit article. Des lois similaires peuvent s’appliquer dans d’autres juridictions. Pour vous procurer un pare-étincelles adapté au système d’évacuation de ce moteur, contactez le fabricant d’équipement d’origine, un revendeur ou un concessionnaire. REMARQUE : Utilisez EXCLUSIVEMENT des pièces de rechange d’origine. Inspectez le silencieux pour vérifier l’absence de fissures, de signes de corrosion ou d’autres dommages. Retirez le pare-étincelles (le cas échéant) et inspectez-le pour vérifiez qu’il n’est pas endommagé, ni obstrué par les dépôts de calamine. Remplacez les pièces endommagées. 19 1. Desserrez la bride (A). Voir la Figure 4-6. 2. Inspectez le cône (C) et remplacez-le s’il est tordu, perforé ou autrement endommagé. Si le cône est en bon état, nettoyez-le à l’aide d’un solvant commercial. 3. Remettez le cône (C) et le collier (B) du pare-étincelles en place. Fixez l’ensemble avec la bride (A). B C A 003467 Figure 4-6. Écran du pare-étincelles Jeu de soupapes IMPORTANT : Contactez un concessionnaire réparateur indépendant agréé pour obtenir de l’aide. Si vous souhaitez prolonger la durée de vie du moteur, il est impératif que le jeu de soupapes soit correctement réglé. Contrôlez le jeu de soupapes après les 50 premières heures de fonctionnement. Ajustez-le si nécessaire. • Admission — 0,05 à 0,08 mm (0,002 à 0,003 po) • Échappement — 0,05 à 0,08 mm (0,002 à 0,003 po) Manuel du propriétaire de générateur portatif Entreposage Préparation du circuit de carburant à l'entreposage Généralités DANGER Explosion et incendie. Le carburant et ses vapeurs sont extrêmement inflammables et explosifs. Entreposez le carburant dans un endroit bien aéré. Gardez-le loin du feu et des étincelles. Le non-respect de cette consigne entraînera la mort ou des blessures graves. (000143) AVERTISSEMENT Risque d’incendie. Vérifiez que l’appareil a bien refroidi avant d’installer une protection de rangement et d’entreposer l’appareil. Le contact avec des surfaces chaudes pourrait entraîner un incendie. (000109) Il est recommandé de démarrer le générateur pour le faire tourner pendant 30 minutes tous les 30 jours. Si cela s’avère impossible, respectez les consignes suivantes pour préparer l’appareil à l’entreposage. • Ne placez JAMAIS un couvercle d’entreposage sur un générateur chaud. Laissez l’appareil refroidir à température ambiante avant de l’entreposer. • N’entreposez JAMAIS de carburant d’une saison à une autre à moins de l’avoir traité de façon appropriée. • Remplacez le conteneur de carburant s’il présente des traces de rouille. La présence de rouille dans le carburant provoque des dysfonctionnements du circuit de carburant. • Recouvrez l’appareil d’un couvercle de protection adapté résistant à l’humidité. • Entreposez l’appareil dans un lieu propre et sec. • Veillez à toujours entreposer le générateur et le carburant à l’écart des sources de chaleur et d’inflammation. Le carburant entreposé pendant plus de 30 jours peut se dégrader et endommager les composants du circuit de carburant. Conservez le carburant frais et utilisez un stabilisateur de carburant. Si un stabilisateur a été ajouté au circuit de carburant, préparez le moteur pour un entreposage de longue durée. Faites tourner le moteur pendant 10 à 15 minutes pour faire circuler le stabilisateur dans l’ensemble du circuit de carburant. Un carburant préparé de façon appropriée peut être entreposé pendant un maximum de 24 mois. REMARQUE : Si le carburant n’a pas été traité avec un stabilisateur, il doit être purgé dans un conteneur adapté. Faites tourner le moteur jusqu’à ce qu’il s’arrête par manque de carburant. Il est recommandé d’utiliser un stabilisateur dans le conteneur d’entreposage afin de conserver le carburant frais. 1. Remplacez l’huile moteur. 2. Retirez la bougie. 3. Versez une cuillère à table (5-10 cm3) d’huile moteur propre ou vaporisez un agent anti-buée adapté dans le cylindre. AVERTISSEMENT Perte de la vision. Une protection oculaire est requise pour éviter les projections provenant du trou de bougie d’allumage pendant le lancement du moteur. Ne pas porter de protection oculaire pourrait entraîner la perte de la vision. (000181) 4. Tirez plusieurs fois la poignée du lanceur à rappel pour distribuer l’huile dans le cylindre. 5. Remettez la bougie en place. 6. Tirez lentement la poignée du lanceur à rappel jusqu’à ressentir une résistance. Cela a pour effet de fermer les soupapes afin d’empêcher la pénétration d’humidité dans le cylindre. Relâchez délicatement la poignée du lanceur à rappel. Remplacement de l’huile Remplacez l’huile moteur avant d’entreposer le générateur. Voir la section Remplacement de l'huile moteur et du filtre à huile. Manuel du propriétaire de générateur portatif 20 Dépannage CAUSE CORRECTION Le moteur tourne, mais aucune sortie CA n’est disponible. PROBLÈME 1. Disjoncteur OUVERT. 2. Mauvais raccordement ou cordon défectueux. 3. Appareil raccordé défectueux. 4. Défaillance interne au générateur. 5. Module du disjoncteur DDFT OUVERT. 1. Réinitialisez le disjoncteur. 2. Contrôlez et réparez. 3. Raccordez un autre appareil qui est en bon état. 4. Contactez un CRIA. 5. Corrigez le défaut de mise à la terre et appuyez sur le bouton Réinitialiser du module du disjoncteur DDFT. Le moteur tourne bien sans charge, mais pas en présence d’une charge. 1. Court-circuit dans une charge connectée. 2. Générateur surchargé. 3. Régime moteur trop lent. 4. Court-circuit interne au générateur. 5. Filtre à carburant sale. 6. Pare-étincelles bouché. 1. Débranchez la charge électrique court-circuitée. 2. Voir la section Connaître les limites de son générateur. 3. Contactez un CRIA. 4. Contactez un CRIA. 5. Remplacez le filtre à carburant. 6. Nettoyez l’écran du pare-étincelles. Le moteur ne démarre pas ou démarre et tourne mal. 1. Robinet d’arrêt de carburant en position ARRÊT. 2. Filtre à air sale. 3. Panne de carburant. 4. Carburant éventé. 5. Fil de la bougie non raccordé à la bougie. 6. Bougie défectueuse. 7. Présence d’eau dans le carburant. 8. Sur-étranglement. 9. Niveau d’huile faible. 10. Mélange de carburant excessivement riche. 11. Soupape d’admission bloquée en position ouverte ou fermée. 12. Perte de compression du moteur. 13. Filtre à carburant sale. 1. Tournez le robinet d’arrêt de carburant en position MARCHE. 2. Nettoyez ou remplacez le filtre à air. 3. Remplissez le réservoir de carburant. 4. Purgez le réservoir de carburant et faites le plein de carburant frais. 5. Raccordez le fil à la bougie. 6. Remplacez la bougie. 7. Purgez le réservoir de carburant et faites le plein de carburant frais. 8. Placez le levier d’étrangleur en position ouverte (pas d'étranglement). 9. Remplissez le carter au niveau approprié. 10. Contactez un CRIA. 11. Contactez un CRIA. 12. Contactez un CRIA. 13. Remplacez le filtre à carburant. Le moteur s’arrête en cours de fonctionnement. 1. Panne de carburant. 2. Niveau d’huile faible. 3. Défaillance interne au moteur. 1. Remplissez le réservoir de carburant. 2. Remplissez le carter au niveau approprié. 3. Contactez un CRIA. Manuel du propriétaire de générateur portatif 21 PROBLÈME CAUSE CORRECTION Le moteur manque de puissance. 1. Charge trop élevée. 2. Filtre à air sale. 3. Maintenance du moteur requise. 4. Filtre à carburant sale. 5. Pare-étincelles bouché. 1. Réduisez la charge (voir la section Connaître les limites de son générateur). 2. Nettoyez ou remplacez le filtre à air. 3. Contactez un CRIA. 4. Remplacez le filtre à carburant. 5. Nettoyez l’écran du pare-étincelles. Le moteur rencontre des sautes de régime ou hésite. 1. L’étranglement s’ouvre trop tôt. 2. Le carburateur fonctionne avec un mélange de carburant trop riche ou trop pauvre. 1. Placez le levier d’étrangleur en position intermédiaire jusqu’à ce que le moteur tourne sans à-coups. 2. Contactez un CRIA. Manuel du propriétaire de générateur portatif 22 Remarques 23 Manuel du propriétaire de générateur portatif Remarques Manuel du propriétaire de générateur portatif 24 Manuel du propriétaire de générateur portatif 25 Pièce n° 10000004327 Rév. B 14/05/2018 ©2018 Generac Power Systems, Inc. Tous droits réservés Les spécifications sont sujettes à modification sans préavis. Aucune forme de reproduction n’est autorisée sans le consentement écrit préalable de Generac Power Systems Inc. Generac Power Systems, Inc. S45 W29290 Hwy. 59 Waukesha, WI 53189 1-888-GENERAC (1-888-436-3722) www.generac.com/pro
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80

Generac XC8000 10000007936 Manual de usuario

Categoría
Generadores de poder
Tipo
Manual de usuario