Westinghouse 7217200 El manual del propietario

Categoría
Ventiladores domésticos
Tipo
El manual del propietario
ETL-ES-GW-Contempra-WH17
OWNER'S MANUAL
MANUAL DEL USUARIO
Contempra
Please write model number here for future reference: /
Por favor, incluya el número del modelo aquí para futura referencia:
Net Weight: LBS
Peso Neto: KGS
2
ETL-ES-GW-Contempra-WH17
1. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards (ANSI/NFPA 70), including fire-rated construction.
2. Use this unit only in the manner intended by the manufacturer. If you have any questions contact the manufacturer.
3. After making the wire connections, gently push connections into outlet box with wire nuts pointing up. The wires should be spread apart with the grounded conductor and the equipment-grounding conductor on
one side of the outlet box and ungrounded conductor on the other side of the outlet box.
4. Before you begin installing the fan, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be
locked, securely fasten a prominent warning device, such as a tag, to the service panel.
5. Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.
6. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
7. Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade.
8. To reduce the risk of fire, electric shock, or personal injury, this fan must be mounted to an outlet box marked suitable for fan support, and use the mounting screws provided with the outlet box. (Mounting must
support at least 35 lbs.)
9. WARNING! Do not bend blade holders during installation to motor, balancing or during cleaning. Do not insert foreign object between rotating blades.
10. Attach the mounting bracket using only the hardware supplied with the outlet box. Fan is only to be mounted to an outlet box marked Acceptable for Fan Support”.
11. WARNING! To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.
12. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.
13. NEVER place a switch where it can be reached from a tub or shower.
14. The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment manufacturer’s guideline safety standards such as those
published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
15. Before servicing or cleaning unit, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be
locked, securely fasten a prominent warning device, such as a tag, to the service panel.
16. All set screws must be checked and re-tightened where necessary before installation.
17. The appliance is not intended for use by young children or infirmed persons without supervision. Young children should be supervised to ensure they do not play with the appliance.
18. Suitable for Indoor/Outdoor Damp Location.
TOOLS REQUIRED
Phillips Screwdriver Wire Cutters Pliers Step Ladder
SAFETY TIPS
OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR PERSONAL INJURY, MOUNT TO OUTLET BOX MARKED 'ACCEPTABLE FOR FAN SUPPORT OF 35 LBS (15.9 KG) OR LESS'
AND USE MOUNTING SCREWS PROVIDED WITH THE OUTLET BOX AND/OR SUPPORT DIRECTLY FROM BUILDING STRUCTURE. MOST OUTLET BOXES COMMONLY USED FOR THE
SUPPORT OF LUMINARIES ARE NOT ACCEPTABLE FOR FAN SUPPORT AND MAY NEED TO BE REPLACED. CONSULT A QUALIFIED ELECTRICIAN IF IN DOUBT.
3
ETL-ES-GW-Contempra-WH17
1. El trabajo de instalación y el cableado eléctrico los deben efectuar personas calificadas cumpliendo con todos los códigos y las normas aplicables (ANSI/NFPA 70), incluyendo las de incendio.
2. Use esta unidad sólo de la manera en que el fabricante quiere que se haga. Si tiene dudas, llame al fabricante.
3. Después de hacer las conexiones, empuje con cuidado las conexiones dentro de la caja de embutir con los conectores de cables mirando hacia arriba. Se deben separar los cables: el conductor de puesta a tierra y el conductor
de puesta a tierra del equipo a un lado de la caja de embutir, y el conductor que no tiene puesta a tierra del otro lado de la misma.
4. Antes de comenzar a instalar el ventilador, apague la alimentación en el panel de servicio y bloquee el medio de desconexión del servicio para evitar que se encienda accidentalmente. Cuando no se puede bloquear el medio
de desconexión del servicio eléctrico, fije de manera segura un dispositivo de advertencia prominente, como un rótulo, al panel de servicio.
5. ¡Tenga cuidado! Lea todas las instrucciones y la información de seguridad antes de instalar su ventilador nuevo. Revise los diagramas de montaje incluidos.
6. Al cortar o perforar una pared o techo, no dañe el cableado eléctrico y otras instalaciones de servicios públicos ocultos.
7. Asegúrese de que el sitio para la instalación que escoja permita que el ventilador gire libremente sin obstrucciones. Deje un espacio mínimo de 7 pies desde le piso hasta el borde posterior de la aleta.
8. Para reducir el riesgo de incendios, choques eléctricos o heridas personales, este ventilador se debe montar sobre una caja de embutir que tenga una marca que indique que es adecuada para soportar un ventilador.
Además debe utilizar los tornillos correspondientes incluidos con la caja de embutir. (El montaje debe soportar por lo menos 35 lbs. (15.9 kgs.).
9. ¡ADVERTENCIA! No doble los soportes para las aletas durante la instalación al motor, al balancear o durante la limpieza. No inserte objetos extraños entre las aletas mientras giran.
10. Fije el soporte de montaje usando sólo la tornillería suministrada con la caja de embutir. El ventilador sólo se debe montar en una caja de embutir marcada Acceptable for Fan Support (Aceptable para soportar ventiladores).
11. ¡ADVERTENCIA! Para reducir el riesgo de incendios o choques eléctricos, no use este ventilador con un dispositivo de control de velocidad de estado sólido para ventilador, o un control de velocidad variable.
12. Si esta unidad se instalará sobre una bañera o una ducha, debe estar identificada como adecuada para ese tipo de aplicación.
13. NUNCA coloque un interruptor donde se pueda alcanzar desde una bañera o una ducha.
14. Es posible que la operación de esta unidad afecte el flujo de aire de combustión necesario para la operación segura de equipo que quema combustible. Siga la directrices de seguridad del fabricante de equipo de calefacción
como las publicadas por la Asociación Nacional de Protección Contra Incendios (National Fire Protection Association, NFPA), y la Sociedad Americana para Ingenieros de Calefacción, Refrigeración y Aire Acondicionado
(American Society for Heating, Refrigeration and Air Conditioning Engineers, ASHRAE) y las autoridades del código local.
15. Antes de efectuar tareas de servicio o limpieza en la unidad, apague la alimentación en el panel de servicio y bloquee el medio de desconexión del servicio para evitar que se encienda accidentalmente. Cuando no se puede
bloquear el medio de desconexión del servicio eléctrico, fije de manera segura y un dispositivo de advertencia prominente, como un rótulo, al panel de servicio.
16. Antes de realizar la instalación, es importante comprobar y volver a ajustar todos los tornillos, según corresponda.
17. El dispositivo no ha sido diseñador para ser utilizado por niños o personas enfermas sin supervisión. Los niños deben ser supervisados para asegurarse de que no juegan con el dispositivo.
18. Adecuado Para Interiores y Exteriores Ubicación Húmeda.
HERRAMIENTAS NECESARIAS
Destornillador Phillips Pinzas de corte Pinzas Escalera de mano
CONSEJOS DE SEGURIDAD
HAGA LO SIGUIENTE: LEA Y GUARDE ESTAS INSTRUCCIONES
ADVERTENCIA: PARA REDUCIR EL RIESGO DE INCENDIO, DESCARGA ELÉCTRICA O HERIDAS PERSONALES, MONTE EN UNA CAJA DE EMBUTIR ROTULADA ADECUADA PARA VENTILADORES DE 35 LB (15,9 KGS )
O MENOS” UTILIZANDO LOS TORNILLOS DE MONTAJE INCLUIDOS CON LA CAJA DE EMBUTIR Y/O MONTE DIRECTAMENTE EN LA ESTRUCTURA DEL EDIFICIO. LA MAYORÍA DE LAS CAJAS DE EMBUTIR UTILIZADAS
NORMALMENTE CON ARTEFACTOS DE ILUMINACIÓN NO SON ADECUADAS PARA VENTILADORES Y DEBERÍAN SER REEMPLAZADAS. SI TIENE PREGUNTAS, CONSULTE A UN ELECTRICISTA CERTIFICADO.
4
ETL-ES-GW-Contempra-WH17
Unpack and inspect fan carefully to be certain all contents are included.
Turn off power at fuse box to avoid possible electrical shock.
1
Use metal outlet box suitable for fan support (must support 35 lbs).
Before attaching fan to outlet box, ensure the outlet box is securely
fastened by at least two points to a structural ceiling member (a loose
box will cause the fan to wobble).
2
PREPARING FOR INSTALLATION
ANTES DE LA INSTALACIÓN
Quite el envoltorio e inspeccione detenidamente el ventilador para verificar
que todas las piezas estén incluidas. Apague la alimentación en la caja de
fusibles para evitar la posibilidad de descarga eléctrica.
Use una caja de embutir de metal adecuada para soportar un ventilador
(debe soportar 35 libras). Antes de fijar el ventilador a la caja de embutir
asegúrese de que la misma esté fijada de manera segura en por lo menos
dos puntos a un miembro estructural del techo (una caja suelta haría
que el ventilador oscile).
5
ETL-ES-GW-Contempra-WH17
MOUNTING BRACKET INSTALLATION
INSTALACIÓN CON SOPORTE DE MONTAJE
3
Remove the screws and star washers (1) from the bracket as shown above.
Loosen (do not remove) the screws (2) from the bracket as shown above.
Install mounting bracket to outlet box in ceiling using the screws and washers
provided with the outlet box.
Quite los tornillos y las arandelas de estrella (1) del soporte como se indica más arriba.
Afloje (no quite) los tornillos (2) del soporte como se indica más arriba.
Instale el soporte de montaje a la caja de embutir del techo con la tornillería
suministrada con la caja de embutir.
1
1
2
2
Remove screws from motor bracket and mounting plate. Hang fan from
mounting plate by inserting "T"-shaped end of bracket into slot opening of
mounting plate. This will allow for hands free wiring.
Extraiga los tornillos del soporte del motor y de la placa de montaje.
Cuelgue el ventilador de la placa de montaje insertando el extremo del
soporte con forma de T” adentro de la ranura de la placa de montaje. De
este modo, tendrá las dos manos libres para hacer el cableado.
4
6
ETL-ES-GW-Contempra-WH17
MOUNTING
MONTAJE
5
While fan is hanging from the mounting plate, connect the wires with wire connectors (included), using the following steps
for wiring options.
Mientras el ventilador está colgado de la placa de montaje, conecte los cables con los conectores para cables (incluidos)
usando los siguientes pasos para opciones de cableado.
7
ETL-ES-GW-Contempra-WH17
WIRING OPTIONS
OPCIÓN DE CABLEADO
7
Follow diagram above to make wiring connections for wall control operation.
6
Follow diagram above to make wiring connections for fan pull chain control.
PULL CHAIN WIRING OPTION
WALL CONTROL WIRING OPTION
Blanco (común)
Negro (vivo)
Azul* (vivo)
Verde (de tierra)
Blanco (común)
Interruptor del ventilador (vivo)
Interruptor de la luz (vivo)
Verde (de tierra)
Del Ventilador: De La Casa:
(conectar)
(conectar)
(conectar)
(conectar)
*Conecte el cable azul sólo si conecta un juego de luces al ventilador.
Control de pared
Siga las instrucciones del diagrama anterior para hacer las conexiones de
cableado para el ventilador con control de pared.
Siga las instrucciones del diagrama anterior para hacer las conexiones de
cableado para el ventilador controlado con cadenilla de tiro.
OPCIÓN DE CABLEADO PARA CADENILLA DE TIRO
OPCIÓN DE CABLEADO PARA CONTROL DE PARED
Note: after wiring is complete, carefully push the wiring back into the outlet box.
Nota: Una vez que el cableado esté completo, vuelva a insertar con cuidado los cables dentro de la caja de embutir.
8
ETL-ES-GW-Contempra-WH17
MOUNTING
MONTAJE
Push motor upward and attach the motor to
the mounting plate by tightly securing with
screws and washers provided.
Empuje el motor hacia arriba y fije el motor
a la placa de montaje asegurando firmemente
con los tornillos y las arandelas incluidos.
8
The decorative motor housing has two mating slots (1) and two
mating holes (2). Position both slots on the motor housing directly
under and in line with two screws in the mounting bracket (3).
Lift the motor housing, allowing the two screws to slide into the
mating slots. Rotate the motor housing clockwise until both screws
from the mounting bracket drop into the slot recesses. Tighten
screws securely.
El alojamiento decorativo del motor tiene dos ranuras coincidentes
(1) y dos agujeros coincidentes (2). Coloque ambas ranuras del
alojamiento del motor directamente abajo y en línea con los dos
tornillos del soporte de montaje (3). Eleve el alojamiento del
motor, permitiendo que los dos tornillos se deslicen dentro de las
ranuras. Gire el alojamiento del motor en sentido horario hasta
que ambos tornillos del soporte de montaje caigan adentro de las
ranuras. Apriete los tornillos asegurándolos.
9
Install two screws and star washers into the mating holes
of the motor housing and tighten to secure the housing to
the mounting bracket.
Instale los dos tornillos y las arandelas de estrella en
los agujeros coincidentes del alojamiento del motor y
ajústelos para asegurar el alojamiento al soporte de
montaje.
10
1
2
3
1
2
9
ETL-ES-GW-Contempra-WH17
BLADE INSTALLATION
INSTALACIÓN DE LAS ALETAS
Check the motor for plastic shipping stabilizer tabs (1), and remove
them if they are present. Attach blade assembly to motor using the
noise-dampening motor gaskets (2) and motor screws provided. Tighten
screws ecurely. NOTE: Some models do not utilize motor gaskets,
washers, or stabilizer tabs.
Verifique si hay lengüetas plásticas de embalaje para sostener al motor
(1) y descártelas. Fije el conjunto de las aletas al motor usando las juntas
reductoras de sonido del motor (2) y los tornillos para el motor incluidos.
Apriete los tornillos asegurándolos. NOTA: Algunos modelos no utilizan
juntas para el motor, arandelas o lengüetas de embalaje.
12
11
Attach blade brackets to blades using the blade bracket screws (1),
metal washers (2), and fabric washers (3), if provided. NOTE: Some
models do not utilize fabric washers (3).
Fije los soportes para aletas a las aletas con los tornillos (1), las
arandelas de metal (2) y las de tela (3), si corresponde.
NOTA: Algunos modelos no utilizan arandelas de tela (3).
1
2
2
10
ETL-ES-GW-Contempra-WH17
13
Assemble decorative fob and extension chains from
hardware bag to fan pull chains by inserting end of chain
into chain coupling. Confirm chains are held by lightly
pulling both chains in coupling.
Adjunta las cadenas largas de tiro con las piezas finales
correspondientes, a las cadenas del ventilador,
introduciendo el extremo de la cadena larga en la pieza
de unión. Asegúrese de que las cadenas están bien sujetas,
tirando ligeramente de ambas cadenas en la pieza de
unión.
11
ETL-ES-GW-Contempra-WH17
Operation
Turn on the power and check operation of fan. The pull chain controls the fan speeds as follows: 1 pull - high; 2 pulls - medium; 3 pulls - low; 4 pulls - off.
Speed settings for warm or cool weather depend on factors such as room size, ceiling height, number of fans and so on. The slide switch controls direction, forward or reverse.
Warm weather/down position - (Forward) Fan turns counterclockwise direction. A downward air flow creates a cooling effect as shown in illustration A.
This allows you to set your air conditioner on a higher temperature setting without affecting your comfort.
Cool weather/up position - (Reverse) Fan turns clockwise direction. An upward airflow moves warm air off the ceiling area as shown in illustration B.
This allows you to set your heating unit on a lower setting without affecting your comfort.
NOTE: Turn off and wait for fan to stop before changing the setting of the forward/reverse slide switch.
Maintenance
1. Because of the fan’s natural movement, some connections may become loose. Check the support connections, brackets, and blade attachments twice a year.
Make sure they are secure.
2. Clean your fan periodically to help maintain its new appearance over the years. Do not use water when cleaning.
This could damage the motor, or the wood, or possibly cause electrical shock.
3. Use only a soft brush or lint-free cloth to avoid scratching the finish. The plating is sealed with a lacquer coating to minimize discoloration or tarnishing.
4. There is no need to oil your fan. The motor has permanently lubricated bearings.
OPERATION AND MAINTENANCE
12
ETL-ES-GW-Contempra-WH17
Operación
Encienda el ventilador y verifique su funcionamiento. La cadenilla de tiro controla las velocidades del ventilador de la siguiente manera:
1 jalón – rápida; 2 jalones - mediana; 3 jalones - lenta; 4 jalones - apagado.
Las velocidades para clima cálido o frío dependen de factores como el tamaño de la habitación, la altura del ventilador,
el número de ventiladores, etc. El conmutador de tipo deslizante controla la dirección, hacia adelante o hacia atrás.
Clima cálido/posición hacia abajo - (Adelante) El ventilador gira en sentido contrahorario. Una corriente de aire descendente crea un efecto refrescante como lo indica la ilustración A.
Esto le permite ajustar el aire acondicionado a una temperatura más alta sin que afecte su comodidad.
Clima frío/posición hacia arriba - (Atrás) El ventilador gira en sentido de las agujas del reloj. Una corriente de aire ascendente aleja el aire caliente del área del ventilador de techo como
lo indica la ilustración B. Esto le permite ajustar la calefacción a un nivel más bajo sin que afecte su comodidad.
NOTA: Apague el ventilador y espere a que se detenga antes de cambiar la dirección de adelante/atrás con el conmutador de tipo deslizante.
Mantenimiento
1. El movimiento natural del ventilador podría hacer que se aflojen algunas conexiones. Verifique las conexiones de soporte, las piezas de fijación y los accesorios de las aletas
dos veces al año. Cerciórese de que estén aseguradas.
2. Limpie el ventilador periódicamente para ayudar a mantener su apariencia nueva con el correr de los años. No use agua para limpiarlo, ya que podría dañar el motor o la
madera o causar descarga eléctrica.
3. Use sólo un cepillo blando o un trapo sin pelusa para no rayar el acabado. El enchapado está sellado con una capa de laca para minimizar la decoloración o pérdida del brillo.
4. No hay necesidad de aceitar el ventilador. El motor tiene cojinetes de lubricación permanente.
OPERACIÓN Y MANTENIMIENTO
13
ETL-ES-GW-Contempra-WH17
13
TROUBLE
1. If fan does not start:
2. If fan sounds noisy:
3. If fan wobbles:
4. If light does not work:
SUGGESTED REMEDY
1. Check main and branch circuit fuses or circuit breakers.
2. Check wire connections as performed in step #6 or #7 of installation.
CAUTION: Make sure main power is turned off.
3. Make sure forward/reverse switch is firmly in up or down position.
Fan will not operate when switch is in the middle.
4. If the fan still will not start, contact a qualified electrician.
Do not attempt to troubleshoot internal electrical connections yourself.
1. Check to make sure all screws in motor housing are snug (not over tightened).
2. Check to make sure the screws which attach the fan blade holder to the motor are tight.
3. If using an optional Ceiling Fan Light Kit, check to be sure the screws securing the glassware are finger tight.
Check to be sure light bulb is tight in socket and not touching glass shade(s). If vibration persists from glass,
remove glass and install a 6mm wide rubber band on glass neck to act as an insulator. Replace glass and tighten
screws against rubber band.
4. Some fan motors are sensitive to signals from Solid State variable speed controls.
DO NOT USE a Solid State variable speed control.
5. Allow “break-in period of 24 hours. Most noises associated with a new fan will disappear after this period.
All blades are weighed and grouped by weight. Natural woods vary in density which could cause the fan to wobble even
though all blades are weight-matched. The following procedures should eliminate most of the wobble. Check for
wobble after each step.
1. Check that all blades are screwed firmly into blade holders.
2. Check that all blade holders are tightened securely to motor.
3. Make sure that canopy and mounting bracket are tightened securely to ceiling joist.
4. Most fan wobble problems are caused when blade levels are unequal. Check this level by selecting a point on the
ceiling above the tip of one of the blades.Measure this distance as shown in Figure 1. Keeping measure within
3mm, rotate the fan until the next blade is positioned for measurement. Repeat for each blade. If all blade levels
are not equal, you can adjust blade levels by the following procedure. To adjust a blade tip down, insert a washer
(not supplied) between the blade and blade holder at the screw closest to the motor (Figure 2). To adjust a blade
tip up, insert washer (not supplied) between the blade and blade holder at the two screws farthest from the
motor (Figure 2).
5. If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can redistribute the weight
and possibly result in smoother operation.
1. Check to see that the wire connections in the switch housing are connected.
2. Check for faulty light bulbs.
3. If light kit will still not operate, contact a qualified electrician for assistance.
Figure 1
Touching
Ceiling
Blade Tip Down:
Fan Blade
Blade Tip Up:
Fan Blade
Blade Brackets
TROUBLESHOOTING GUIDE
If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation, or wiring. In some
cases, these installation errors may be mistaken for defects. If you experience any faults, please check this Trouble Shooting chart.
If a problem cannot be remedied, please consult with your qualified electrician and do not attempt any electrical repairs yourself.
14
ETL-ES-GW-Contempra-WH17
PROBLEMA
1. Si el ventilador no arranca:
2. Si el ventilador es ruidoso:
3. Si el ventilador oscila:
4. Si la luz no funciona:
SOLUCIÓN SUGERIDA
1. Compruebe los fusibles o disyuntores principales y del circuito derivado.
2. Compruebe el cableado del bloque de terminales como lo hizo en el paso No. 6 ó 7 de la instalación.
ADVERTENCIA: Asegúrese de que la alimentación principal esté apagada.
3. Asegúrese de que el interruptor de marcha adelante/atrás esté firmemente en su posición.
El ventilador no funcionará si el interruptor está en el medio.
4. Si el ventilador no arranca, póngase en contacto con un electricista calificado.
No intente reparar conexiones eléctricas internas.
1. Compruebe para asegurarse de que todos los tornillos del alojamiento del motor estén ajustados
(no los apriete demasiado).
2. Compruebe para asegurarse de que los tornillos que fijan el soporte de la aleta del ventilador al motor
estén apretados.
3. Si está usando un juego opcional de luces para el ventilador de techo, compruebe para asegurarse de que los
tornillos que fijan las pantallas de vidrio estén apretados a mano. Compruebe para asegurarse de que las
lámparas estén ajustadas en los receptáculos y que no toquen la(s) pantalla(s) de vidrio. Si la vibración del vidrio
persiste, retire las pantallas de vidrio e instale una arandela de caucho de 6 mm de ancho sobre el cuello del vidrio
para que actúe como aislador. Vuelva a instalar la pantalla de vidrio y apriete los tornillos contra la banda de caucho.
4. Algunos motores de ventilador son sensibles a las señales de los controles de velocidad variable de estado
sólido para motores. NO USE un control de velocidad variable de estado sólido.
5. Permita el "rodaje" del ventilador durante un período de 24 horas. La mayoría de los ruidos asociados con
el ventilador nuevo desaparecerán después de este período.
Todas las aletas se pesan y agrupan según el peso. Las maderas naturales varían en densidad y podrían hacer que el ventilador
oscile aún cuando todas las aletas estén agrupadas por peso. Los siguientes procedimientos deberían eliminar la mayoría de los
problemas de oscilación. Verifique la oscilación después de cada paso.
1. Verifique que todas las aletas estén firmemente atornilladas a los soportes de las aletas.
2. Verifique que todos los soportes de las aletas estén firmemente aseguradas al motor.
3. Asegúrese de que el dosel y el soporte de montaje estén firmemente asegurados a la viga del cielorraso.
4. La mayoría de los problemas de oscilación del ventilador ocurren cuando los niveles de las aletas no son iguales.
Compruebe este nivel seleccionando un punto en el cielorraso sobre el extremo de una de las aletas. Mida la
distancia como se muestra en la Figura 1. Manteniendo la medición con un margen de 3 mm, gire el ventilador
hasta que la próxima aleta esté colocada en el sitio para la medición. Repita el procedimiento para cada aleta.
Si los niveles de las aletas son diferentes, puede ajustar los niveles de las aletas usando el siguiente procedimiento:
Para ajustar hacia abajo el extremo de una aleta, inserte una arandela (no incluida) entre la aleta y el soporte de la
misma en el tornillo más cercano al motor (Figura 2). Para ajustar hacia arriba el extremo de una aleta, inserte una
arandela (no incluida) entre la aleta y el soporte de la misma en los dos tornillos más alejados del motor (Figura 2).
5. Si la oscilación de la aleta sigue siendo visible, es posible que al intercambiar dos aletas adyacentes (lado a lado) se
redistribuya el peso y el funcionamiento sea más suave.
1. Verifique que el conector molex del alojamiento del interruptor esté conectado.
2. Compruebe si hay lámparas defectuosas.
3. Si el conjunto de luces no funciona, póngase en contacto con un electricista calificado.
Figura 1
Figura 2
Tocando el
techo
Extremo de la aleta
hacia abajo:
Aleta del ventilador
Extremo de la aleta
hacia arriba:
Aleta del ventilador
Soportes de las aletas
GUÍA PARA SOLUCIONAR PROBLEMAS
Si tiene dificultades para hacer funcionar su nuevo ventilador, podría ser a causa del armado, instalación o cableado incorrectos. En algunos
casos, estos errores de instalación podrían ser confundidos con defectos. Si experimenta alguna falla, consulte esta guía para solucionar
problemas. Si no puede solucionar el problema, consulte a un electricista calificado y no intente reparar conexiones eléctricas.
15
ETL-ES-GW-Contempra-WH17
PARTS LIST
LISTA DE REPUESTOS
# Description
1. . . . . . . . . . . . . . . . . . . . . . Mounting Bracket
2. . . . . . . . . . . . . . . . . . . . . . Blade Bracket
3. . . . . . . . . . . . . . . . . . . . . . Blade
4. . . . . . . . . . . . . . . . . . . . . . Fan Speed Switch
5. . . . . . . . . . . . . . . . . . . . . . Capacitor
6. . . . . . . . . . . . . . . . . . . . . . Hardware Pack
No. Descripción
1. . . . . . . . . . . . . . . . . . . . . .Soporte de montaje
2. . . . . . . . . . . . . . . . . . . . . .Soporte para aleta
3. . . . . . . . . . . . . . . . . . . . . .Aleta
4. . . . . . . . . . . . . . . . . . . . . .Interruptor de control de
. . . . . . . . . . . . . . . . . . . . . . .velocidad para ventilador
5. . . . . . . . . . . . . . . . . . . . . .Condensador
6. . . . . . . . . . . . . . . . . . . . . .Tornillería
1
3
6
5
4
2
ETL-ES-GW-Contempra-WH17
Westinghouse Lighting, Philadelphia, PA 19154-1029, U.S.A.
www.westinghouselighting.com
, WESTINGHOUSE, and INNOVATION YOU CAN BE SURE OF
are trademarks of Westinghouse Electric Corporation
Used under license by Westinghouse Lighting
All rights reserved.
Made in China
1 / 1

Westinghouse 7217200 El manual del propietario

Categoría
Ventiladores domésticos
Tipo
El manual del propietario

En otros idiomas