WARNING
IMPORTANT: NEVER attempt to do any work without shutting o the electricity.
- Read all instructions before installing.
- System is intended for installation by a qualied electrician in accordance with the National Electrical Code and local regulations.
- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the
circuit breaker switch(es) that control the power to the xture or room that you are working on.
- Place the wall switch in the OFF” position.
CAUTION
- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or
broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this xture.
CAUTION When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
AVERTISSEMENT
IMPORTANT : Coupez l’électricité avant TOUTE manipulation.
- Lisez toutes les instructions avant d’installer.
- Système est destiné à être installé par un électricien qualié en conformité avec le code national de l’électricité et les règlements locaux.
- Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »).
- Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE
- Toutes les pièces doivent être utilisées tel quil est indiqué dans ces instructions. Ne remplacez pas les pièces, nen laissez pas de côté et ne
les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN
GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIA
IMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico.
- Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.
- Sistema está disenado para ser instalado por un electricista calicado, de acuerdo con el código eléctrico nacional y las normas locales.
- Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la
posición “OFF” (APAGADO).
- Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN
- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice
piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calicación
ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
INSTALLATION INSTRUCTIONS
Window - Wall Sconce
WS-W230505-CS, WS-W230511-CS
WS-W230505-CS WS-W230511-CS
5"
5"
3 11
16
"
3 11
16
"
4"
5"
11"
3 11
16
"
9 11
16
"
4"
The instructions apply to the model(s) below:
2
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. MAY 2023
waclighting.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters, East Manufacturing Facility
44 Harbor Park Drive
Port Washington, NY 11050
South East Manufacturing Facility
1600 Distribution Ct
Lithia Springs, GA 30122
Central Manufacturing Facility
1700 South J Elmer Freeway, Ste 100
Cedar Hill, TX 75104
West Manufacturing Facility
1750 S Archibald Ave
Ontario, CA 91761
INSTALLATION INSTRUCTIONS
Window - Wall Sconce
WS-W230505-CS, WS-W230511-CS
HARDWARE
FIG.1
FIG.2
OVERVIEW
Window wall sconce is an indoor/outdoor rated wall mount xture with up, down, and front lights. It is a 4 CCTs selectable xture.
The up and down light has dynamic beam control. The front panel light has on-board dimming control.
FIXTURE INSTALLATION
1. Carefully unpack your new xture and lay out all the parts on a clear area. Be carefully not to lose any small parts necessary for installation.
(See FIG.1)
2. Remove the screw holding mounting plate to xture, and remove mounting plate from xture. (See FIG.2)
3. Secure mounting plate to the junction box in wall provided by others. (See FIG.2)
4. Pull power supply wires out of junction box through mounting back plate. Connect black xture wire to hot wire, white xture wire to
neutral wire and green xture wire to ground. This xture oers 0-10V dimming capability. To utilize, connect purple xture wire to hot
dimming wire and pink xture wire to neutral dimming wire. If not utilizing 0-10V dimming, terminate the dimming wires by capping them
separately. After wires are connected securely, tuck them carefully inside the junction box. (See FIG.2)
5. Put the xture onto the mounting plate, and secure with screws. (See FIG.2)
Wire Connector
Qty: 3pcs
7EAC112201
Junction Box Screw
Qty: 3pcs
7MPF0825F1
4" Junction Box
(Not Included)
Junction Box Mounting Back Plate
Junction Box Mounting Screws
(Supplied)
Fixture Mounting Screws
(Top and Bottom)
Fixture
3
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. MAY 2023
waclighting.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters, East Manufacturing Facility
44 Harbor Park Drive
Port Washington, NY 11050
South East Manufacturing Facility
1600 Distribution Ct
Lithia Springs, GA 30122
Central Manufacturing Facility
1700 South J Elmer Freeway, Ste 100
Cedar Hill, TX 75104
West Manufacturing Facility
1750 S Archibald Ave
Ontario, CA 91761
INSTALLATION INSTRUCTIONS
Window - Wall Sconce
WS-W230505-CS, WS-W230511-CS
On-Board Dimming & CCT Switching
Use a screw driver to rotate the On-Board Dimming Knob to control the brightness of the front panel light.
Use a screw driver to rotate the CCT Switching Knob to select the CCT of all three lights, 2700K, 3000K, 3500K, 4000K.
BEAM ANGLE ADJUSTMENT UP LIGHT AND DOWN LIGHT
The beam angle of the up light and down light is dynamically adjustably by using ngers to move the window brackets to the center of the
light, same structures for both up light and down light.
Use the markings on the back plate to make your beam angle symmetrical as desired.
Beam Angle Markings