Installation and Maintenance Instructions
2
31
2
31
32
GB
3/2 solenoid valves NC-NO-U, direct operated,
brass or stainless steel body, series 314 1/8 - 1/4
DESCRIPTION
Series 314, 3/2 NC-NO-U:
Solenoid valves with threaded 1/8-1/4 connections. Brass
or stainless steel body.
Coils: All 238 basic numbers are UL & CSA approved and
marked with the UR (recognised component) & CSA logos.
ATEX versions:
See “Special conditions for safe use”.
SPECIAL CONDITIONS FOR SAFE USE
For solenoid operators to ATEX, the instructions for use
given in the specifi c Installation Instructions provided with
the product must be strictly followed.
Solenoid valves with threaded connections: Standard
versions or versions equipped with solenoid operators, Ex d,
Ex e mb, Ex mb, Ex tc (SG), for use in explosive atmospheres
to ATEX-IECEx.
ASSEMBLY
The components ASCO are intended to be used only with-
in the technical characteristics specifi ed on the nameplate
or in the documentation. To avoid damage to the equipment,
make sure to prevent the liquid from solidifying at low tem-
peratures and stay within the maximum and minimum tem-
perature limits.
Modifi cations to the equipment may only be made after
consulting the manufacturer or his representative.
Before installation, depressurise the piping system and clean
internally.
The solenoid valves may be mounted in any position with-
out affecting operation.
The direction of fl ow is indicated by markings on the valve’s
body and in the documentation.
Pipe connections have to be in accordance with the size
indicated on the body, label or in the product leafl et.
CAUTION :
Reducing the connections may cause improper operation
or malfunction.
For the protection of the equipment, install a strainer or fi lter
suitable for the service involved in the inlet side as close to
the product as possible.
If tape, paste, spray or a similar lubricant is used when
tightening, avoid particles entering the system.
Use proper tools and locate wrenches as close as possible
to the connection point.
To avoid damage to the equipment, DO NOT OVERTIGHTEN
pipe connections. Observe a maximum tightening torque of
5 to 7 Nm.
Do not use the valve or solenoid operator as a lever.
Pipe connections should not apply any force, torque or strain
to the product.
ELECTRICAL CONNECTION
All electrical connections must only be made by trained and
qualifi ed personnel and have to be in accordance with the
local regulations and standards.
CAUTION:
Before any intervention, turn off the electrical current to
power off the components.
All screw terminals must be properly tightened before putting
into service.
Depending on the voltage, electrical components must be
grounded according to local standards and regulations.
To ensure ground continuity of the coil, make sure it is cor-
rectly positioned during assembly/disassembly (no. 1).
The equipment is electrically connected as follows:
Detachable connector to ISO 4400 / EN 175301-803, form A
(On proper connection and when the (supplied or selected)
connector used is IP65- or IP67-rated, the solenoid valve
will have IP65 or IP67 protection).
PUTTING INTO OPERATION
Before pressurising the circuit, perform an electrical test. In
case of solenoid valves, energise the coil a few times and
notice a metal click signifying the solenoid operation.
FUNCTION
Most solenoid valves are equipped with coils for continuous
duty service. To prevent the risk of personal injury, do not
touch the solenoid operator which can become hot under
normal operating conditions. If the solenoid valve is easily
accessible, the installer must provide protection against
accidental contact.
Our solenoid valves and pilot valves are designed to operate
with devices compliant with EN 61131-2 standard.
SOUND EMISSION
The emission of sound depends on the application, fl uid
and type of equipment used. The exact determination of the
sound level can only be carried out by the user having the
valve installed in his system.
MAINTENANCE
Maintenance of ASCO products is dependent on service
conditions. Periodic cleaning is recommended, the timing of
which will depend on the fl uids used and the service condi-
tions. During servicing, the components must be checked for
excessive wear. A complete set of internal parts is available
as a spare parts or rebuild kit. If a problem occurs during
installation/maintenance or in case of doubt, please contact
ASCO or authorised representatives.
DISASSEMBLY
Disassemble the parts in the order indicated in the views in
these I&M Instructions
1 - Remove the retaining clip (1), maintain pressure downwards,
and the coil (2) (see coil codes on following pages).
2 - Remove the fl at spring (10).
2 - Unscrew the core-tube unit (3) and separate it from the
body (4).
3 - Remove the core/spring unit (5)(6) and the seal (8).
4 - Clean or replace all parts.
REASSEMBLY
Reassemble the parts in the reverse order of disasseambly.
Make sure the retaining clip is correctly positioned on the
coil (see drawing).
The exhaust must be connected to prevent contamination of
the inside of the solenoid valve.
NOTE:
1 - Grease the seal (8) and lightly coat the outer circumfer-
ence of the core with a lubricant conforming to standard
AFNOR ISO TR 3498 categories HL and FC.
2 - Make sure the core-tube unit is properly tightened at a
torque (a).
3 - Replace fl at spring, coil and retaining clip. Connect the
connector assembly.
4 - After reassembly, operate the solenoid valve several times
to ensure the valves open and close properly.
5 - Reassemble the piping connections and tighten at a
maximum torque of 5 to 7 Nm.
MISE EN SERVICE
Avant de mettre le circuit sous pression, effectuer un essai
électrique. Dans le cas d’une électrovanne, mettre la bobine
sous tension plusieurs fois et écouter le “clic” métallique qui
signale le fonctionnement de la tête magnétique.
FONCTIONNEMENT
La plupart des électrovannes comportent des bobinages
prévus pour mise sous tension permanente. Pour éviter
toute brûlure, ne pas toucher la tête magnétique qui, en
fonctionnement normal et en permanence sous tension,
peut atteindre une température élevée. Si l’électrovanne est
facilement accessible, l’installateur doit prévoir une protection
empêchant tout contact accidentel.
Nos électrovannes et électrovannes-pilotes sont prévues
pour fonctionner avec des dispositifs conformes norme
EN 61131-2
BRUIT DE FONCTIONNEMENT
Le bruit de fonctionnement varie selon l’utilisation, le fl uide et
le type de matériel employé. L’utilisateur ne pourra déterminer
avec précision le niveau sonore émis qu’après avoir monté
le composant sur l’installation.
ENTRETIEN
L’entretien nécessaire aux produits ASCO varie avec leurs
conditions d’utilisation. Il est souhaitable de procéder à un
nettoyage périodique dont l’intervalle varie suivant la nature
du fl uide, les conditions de fonctionnement et le milieu
ambiant. Lors de l’intervention, les composants doivent être
examinés pour détecter toute usure excessive. Un ensemble
de pièces internes est proposé en pièces de rechange pour
procéder à la réfection. En cas de problème lors du montage/
entretien ou en cas de doute, veuillez contacter ASCO ou
ses représentants offi ciels.
DEMONTAGE
Démonter les pièces en suivant l’ordre indiqué sur les vues
de cette notice.
1 - Oter le clip de maintien (1), en maintenant une pression
vers le bas, et enlever la bobine (2) (voir codes bobines,
pages suivantes).
2 - Retirer le ressort plat (10)
3 - Dévisser l'ensemble tube-culasse (3) et le séparer du
corps (4).
4 - Enlever l’ensemble noyau ressort (5)(6) et le joint d’étan-
chéité (8).
5 - Nettoyer ou remplacer toutes les pièces.
REMONTAGE
Remonter les pièces dans l’ordre inverse du démontage.
S’assurer que le clip de maintien est correctement positionné,
sur la bobine (voir dessin).
La purge doit être raccordée pour éviter toute pollution interne
de l'électrovanne.
NOTE :
1 - Lubr
ifi er le joint d’étanchéité (8) et lubrifi er légèrement le
diamètre extérieur du noyau avec une huile conforme aux
normes AFNOR ISO TR 3498 catégorie HL et FC.
2 - S'assurer du serrage correct de l'ensemble tube-culasse,
couple de serrage (a)
3 - Replacer le ressort plat, la bobine et le clip de maintien.
Raccorder le connecteur.
4 - Après remontage, faire fonctionner l'électrovanne plu-
sieurs fois afi n de s’assurer qu’ils s’ouvrent et se ferment
correctement.
5 - Remonter les raccords de tuyauterie, couple de serrage
maximum entre 5 et 7 Nm.
Instructions de mise en service et d'entretien
2
31
2
31
32
FR
Electrovannes 3/2 NF-NO-U, à commande directe
corps laiton ou acier inox, séries 314 1/8 - 1/4
DESCRIPTION
Série 314, 3/2 NF-NO :
Electrovannes, taraudé 1/8-1/4. Corps laiton ou acier inox.
Bobines : Tous les codes de base 238 sont agréés UL & CSA
avec les logos UL & CSA qui conviennent.
Versions ATEX :
Voir "conditions spéciales pour une utilisation sûre".
CONDITIONS SPECIALES POUR UNE UTILISATION SURE
Pour les têtes magnétiques ATEX, suivre impérativement
les prescriptions d'utilisation décrites dans chaque notice
de mise en service spécifi que fournie avec le produit.
Electrovannes, corps taraudé : Versions standard ou
équipées de têtes magnétiques pour atmosphères explo-
sibles ATEX-IECEx, Ex d, Ex e mb, Ex mb, Ex tc (SG).
MONTAGE
Les composants ASCO sont conçus pour les domaines
de fonctionnement indiqués sur la plaque signalétique ou la
documentation. Afi n de prévenir tout dommage sur le maté-
riel, éviter le risque de solidifi cation des liquides aux basses
températures et respecter les limites minimale et maximale.
Aucune modifi cation ne peut être réalisée sur le matériel
sans l’accord préalable du fabricant ou de son représentant.
Avant de procéder au montage, dépressuriser les canalisa-
tions et effectuer un nettoyage interne.
Les électrovannes peuvent être montées dans n’importe
quelle position.
Le sens de circulation du fl uide est indiqué par repères sur
le corps et dans la documentation.
La dimension des tuyauteries doit correspondre au raccor-
dement indiqué sur le corps, l’étiquette ou la notice.
ATTENTION :
Une restriction des tuyauteries peut entraîner des dysfonc-
tionnements.
Afi n de protéger le matériel, installer une crépine ou un fi ltre
adéquat en amont, aussi près que possible du produit.
En cas d’utilisation de ruban, pâte, aérosol ou un lubrifi ant
lors du serrage, veiller à ce qu’aucun corps étranger ne
pénètre dans le circuit.
Utiliser un outillage approprié et placer les clés aussi près
que possible du point de raccordement.
Afi n d’éviter toute détérioration, NE PAS TROP SERRER
les raccords des tuyauteries. Couple de serrage maximum
entre 5 et 7 Nm.
Ne pas se servir de la vanne ou de la tête magnétique
comme d’un levier.
Les tubes de raccordement ne devront exercer aucun effort,
couple ou contrainte sur le produit.
RACCORDEMENT ÉLECTRIQUE
Le raccordement électrique doit être réalisé par un personnel
qualifi é et selon les normes et règlements locaux.
ATTENTION:
Avant toute intervention, couper l’alimentation électrique
pour mettre hors tension les composants.
Toutes les bornes à vis doivent être serrées correctement
avant la mise en service.
Selon la tension, les composants électriques doivent être mis
à la terre conformément aux normes et règlements locaux.
Afi n d'assurer la continuité de masse de la bobine, veuillez
à son positionnement correct lors d'une phase de montage/
démontage (rep. 1).
Le raccordement électrique s’effectue par:
Connecteur débrochable ISO 4400 / EN 175301-803, forme
A (Quand le raccordement est correctement effectué et que
le modèle de connecteur fourni ou sélectionné est IP65 ou
IP67, alors le degré de protection de l'électrovanne est IP65
ou IP67).
524685-001 / A
Availability, design and specifi cations are subject to change without notice. All rights reserved.
524685-001 524685-001
4 5
Inbetriebnahme- und Wartungsanleitung
2
31
2
31
32
DE
Magnetventile 3/2 NC-NO-U, direkt betätigt
Gehäuse aus Messing oder Edelstahl, 1/8 - 1/4, Baureihe 314
BESCHREIBUNG
Baureihe 314, 3/2 NC-NO-U:
Magnetventile mit 1/8-1/4 -Gewindeanschlüssen, Messing oder
Edelstahl.
Magnetspule: Alle 238 Basisnummern sind UL- und CSA-
zugelassen und mit den entsprechenden UL- und CSA-Logos
gekennzeichnet.
Ausführungen nach ATEX:
Siehe „Besondere Bedingungen für den sicheren Einsatz“:
BESONDERE BEDINGUNGEN FÜR DEN SICHEREN EINSATZ
Für die Magnetköpfe nach ATEX sind die in den jeweiligen,
dem Produkt beigelegten Einbau- und Wartungsanweisun-
gen beschriebenen Einsatzvorschriften zwingend zu befol-
gen.
Magnetventile -Gewindeanschlüssen: Standard-Versi-
on oder Version mit Magnetköpfen - Ex d, Ex e mb, Ex mb,
Ex tc (SG) - für den Einsatz in explosionsfähigen Atmosphä-
ren nach ATEX-IECEx.
EINBAU
ASCO-Komponenten dürfen nur innerhalb der auf dem Ty-
penschild oder in der Dokumentation angegebenen Daten
eingesetzt werden. Um Schäden am Ventil zu vermeiden ist
darauf zu achten, dass ein Gefrieren des Medium bei Minu-
stemperaturen vermieden wird und die minimal und maximal
angegebenen Temperaturen eingehalten werden.
Änderungen an den Produkten dürfen nur nach vorheriger
Zustimmung des Herstellers oder einem seiner ordnungsge-
mäß ermächtigten Vertreter vorgenommen werden.
Vor dem Einbau der Ventile muss das Rohrleitungssystem
drucklos geschaltet und innen gereinigt werden.
Die Magnetventile können ohne Beeinträchtigung der Funk-
tion in jeder beliebigen Einbaulage montiert werden.
Die Durchfl ussrichtung des Mediums ist am Gehäuse und
in der Dokumentation angezeigt
Die Verrohrung sollte entsprechend den Größenangaben
auf dem Gehäuse, dem Etikett oder den Produkt-Datenblät-
tern durchgeführt werden.
ACHTUNG:
Eine Reduzierung der Anschlüsse kann zu Leistungs- und
Funktionsminderungen führen.
Zum Schutz der Ventile ist ein geeigneter Schmutzfänger oder
Filter so nahe wie möglich am Ventileingang anzubringen.
Bei der Abdichtung des Gewindes mit Band, Paste, Spray
oder einem anderen Dichtungsmittel ist darauf zu achten,
dass keine Fremdkörper in das System gelangen.
Zur Montage ist nur geeignetes Werkzeug zu verwenden;
die Schraubenschlüssel sind so nahe wie möglich an den
Verbindungsstellen anzusetzen.
Um Schäden zu vermeiden, dürfen die Rohrverbindungen
NICHT ZU STARK angezogen werden. Der maximale An-
ziehdrehmoment beträgt 5 bis 7 Nm.
Das Ventil oder der Magnetkopf sind nicht als Gegenhalter
zu benutzen.
Die Rohrleitungsanschlüsse dürfen keine Spannungen auf
das Ventil übertragen.
ELEKTRISCHER ANSCHLUSS
Der elektrische Anschluss ist von Fachpersonal entspre-
chend den vor Ort geltenden Normen und Richtlinien durch-
zuführen.
ACHTUNG:
Vor Beginn jeglicher Arbeiten ist sicherzustellen, dass die
Komponenten spannungslos geschaltet sind.
Alle Anschlussklemmen sind vor Inbetriebnahme vorschrifts-
mäßig anzuziehen.
Je nach Spannungsbereich müssen elektrische Komponen-
ten einen Schutzleiteranschluss entsprechend den jeweils
vor Ort geltenden Normen und Vorschriften erhalten.
Um den Masseanschluss des Magnets zu gewährleisten
ist auf die korrekte Lage des Magnets bei den Einbau- und
Ausbaumaßnahmen zu achten (Nr. 1).
Der elektrische Anschluss erfolgt folgendermaßen:
Abnehmbare Leitungsdose nach ISO 4400 / EN 175301-803,
bauform A (Bei ordnungsgemäß durchgeführtem Anschluss
und bei Verwendung einer Leitungsdose (mitgeliefert oder
kundenseitig) der Schutzart IP65 oder IP67, hat das Mag-
netventil die Schutzart IP65 bzw. IP67).
INBETRIEBNAHME
Vor Druckbeaufschlagung des Produktes sollte eine elektri-
sche Funktionsprüfung erfolgen. Bei einem Magnetventil ist
die Spannung am Magnet mehrmals ein- und ausschalten.
Es muss ein Klicken zu hören sein.
FUNKTIONSBESCHREIBUNB
Die meisten Ventile sind mit Spulen für Dauerbetrieb aus-
gerüstet. Zur Vermeidung von Personen- und Sachschäden
sollte jede Berührung mit dem Magnet vermieden werden,
da dieser bei längerem Betrieb heiß werden kann. Bei leicht
zugänglichem Magnetventil sollte vom Installateur ein Schutz
vorgesehen werden, um jegliches versehentliches Berühren
zu vermeiden.
Unsere Magnetventile und Pilotventile sind für den Betrieb
mit Betriebsmitteln nach der Norm EN 61131-2 ausgelegt.
GERÄUSCHEMISSION
Der Anwender kann erst präzise Angaben zur Geräusche-
mission machen, wenn das Gerät in der Anlage installiert ist.
Diese hängt sehr stark vom Anwendungsfall, den Betriebs-
daten und dem Medium, mit denen das Produkt beaufschlagt
wird, ab.
WARTUNG
Die Wartung hängt von den Betriebsbedingungen ab. Das
Ventil ist in regelmäßigen Zeitabständen zu reinigen. Die
Zeitabstände hängen von den Betriebsbedingungen und
dem verwendeten Medium ab. Während des Reinigungsvor-
gangs sollten alle Teile auf Verschleiß untersucht werden. Die
Innenteile sind komplett als Ersatzteilsatz erhältlich. Treten
Schwierigkeiten beim Einbau oder bei der Wartung auf oder
ergeben sich Unklarheiten, ist mit ASCO Rücksprache zu
halten.
AUSBAU
Bauen Sie die Teile in der Reihenfolge ab wie in den Zeich-
nungen in dieser Anleitung angegeben.
1 - Entfernen Sie den Halteclip (1), dabei den Druck nach
unten beibehalten, und den Magnet (2) (siehe Bestell-
Codes der Magnete auf der Folgende Seiten).
2 - Entfernen Sie die Flachfeder (10)
3 - Lösen Sie die Führungsrohr-Einheit (3) und nehmen Sie
diese aus dem Gehäuse (4).
4 - Entfernen Sie die Magnetanker/Feder-Einheit (5)(6) und
die Dichtung (8).
5 - Reinigen oder ersetzen Sie alle Teile.
WIEDEREINBAU
Setzen Sie die Teile in der umgekehrten Reihenfolge wie
beim Ausbau zusammen.
Stellen Sie sicher, dass der Halteclip richtig auf dem Magnet
platziert ist (siehe Zeichnung).
Der Entlüftungsanschluss ist mit einem Schalldämpfer zu
versehen, um eine Verschmutzung der Innenteile des Ventils
zu vermeiden.
ANMERKUNG:
1 - Fetten Sie die Dichtung (8) ein und schmieren Sie den
Außendurchmesser des Magnetankers mit einer leichten
Schicht Fett ein, das der Norm AFNOR ISO TR 3498,
Kategorien HL und FC, entspricht.
2 - Vergewissern Sie sich, dass die Führungsrohr-Einheit
richtig mit einem Drehmoment (A) festgezogen ist.
3 - Flachfeder, Spule und Halteklammer wieder anbringen.
Gerätesteckdose anschließen.
4 - Nach dem Wiedereinbau bzw. der Ventilblock mehrmals
ein- und auszuschalten um sicherzustellen, dass die Ventile
richtig öffnen und schließen.
5 - Montieren Sie die Rohrleitungsanschlüsse und ziehen Sie
sie mit einem maximalen Drehmoment von 5 bis 7 Nm fest.
Instrucciones de puesta en marcha y mantenimiento
2
31
2
31
32
ES
Electroválvulas 3/2 NC-NA-U, de mando directo
cuerpo de latón o acero inox, 1/8 - 1/4, series 314
DESCRIPCIÓN
Serie 314, 3/2 NC-NA:
Electroválvulas, roscada 1/8-1/4. Cuerpo de latón o acero inox.
Bobinas: los 238 números básicos están homologados por
UL y CSA y están marcados con los logotipos correspon-
dientes de UL y CSA.
Versiones ATEX:
Ver "condiciones especiales para una utilización segura".
CONDICIONES ESPECIALES PARA UNA
UTILIZACIÓN SEGURA
Para las cabezas magnéticas ATEX, siga imperativa-
mente las prescripciones de utilización descritas en cada
hoja de puesta en marcha específi ca provista con el
producto.
Electroválvulas, cuerpo roscado : Versiones standard o
equipadas de cabezas magnéticas para atmósferas explo-
sivas ATEX-IECEx, Ex d, Ex e mb, Ex mb, Ex tc (SG).
MONTAJE
Los componentes ASCO están diseñados para los campos
de funcionamiento indicados en la placa de características
o la documentación. Con el fi n de prevenir todo daño en el
material, evite el riesgo de solidifi cación de los líquidos a
bajas temperaturas y respecte los límites mínimo y máximo.
No se puede realizar ninguna modifi cación en el material
sin el acuerdo previo del fabricante o de su representante.
Antes de proceder al montaje, despresurice las canaliza-
ciones y realice una limpieza interna.
Las electroválvulas pueden ser montadas en cualquier
posición.
El sentido de circulación del fl uido está indicado por refe-
rencias en el cuerpo y en la documentación.
La dimensión de las tuberías debe corresponder al racordaje
indicado en el cuerpo, la etiqueta o la noticia.
ATENCIÓN:
La reducción de las conexiones puede causar operaciones
incorrectas o defectos de funcionamiento.
Para la protección del equipo se debe instalar en la parte
de la entrada y tan cerca como sea posible del producto un
ltro o tamizador adecuado para el servicio.
Si se utilizara cinta, pasta, spray u otros lubricantes en el
ajuste, se debe evitar que entren partículas en el producto.
Se debe utilizar las herramientas adecuadas y colocar llaves
lo más cerca posible del punto de conexión.
Para evitar daños al equipo, NO FORZAR las conexiones
a la tubería.
No utilizar la válvula o el solenoide como palanca.
Las conexiones a la tubería no producirán ninguna fuerza,
apriete o tensión sobre el producto.
CONEXIÓN ELÉCTRICA
Las conexiones eléctrica deberan realizarse por personal
cualifi cado y según las normas y reglamentos locales.
ATENCIÓN:
Antes de comenzar el trabajo, desconecte el suministro de
energía eléctrica y desenergice el circuito electrónico y los
elementos portadores de tensión.
Todos los terminales eléctricos deben estar apretados ade-
cuadamente según normas antes de su puesta en servicio.
Según el voltaje, los componentes electrónicos deben
disponer de una conexión a tierra y satisfacer las normas
y regulaciones locales.
Con el fi n de asegurar la continuidad de masa de la bobi-
na, compruebe su correcta colocación durante el montaje/
desmontaje. (ref. 1)
La conexión eléctrica se realiza mediante:
Conector desenchufable ISO 4400 / EN 175301-803, forma A
(Cuando la conexión se ha realizado correctamente y el
modelo de conector suministrado o seleccionado es IP65 o
IP67, entonces el grado de protección de la electroválvula
es IP65 o IP67).
PUESTA EN MARCHA
Se debe efectuar una prueba eléctrica antes de someter a
presión el sistema. En el caso de las válvulas solenoides,
se debe energizar varias veces la bobina y comprobar que
se produce un sonido metálico que indica el funcionamiento
del solenoide.
FUNCIONAMIENTO
La mayor parte de las válvulas solenoides se suministran
con bobinas para un servicio continuo. Con el fi n de evitar
la posibilidad de daños personales o materiales no se debe
tocar el solenoide, ya que puede haberse calentado en con-
diciones normales de trabajo. Si la electroválvula es de fácil
acceso, el instalador debe prever una protección que impida
cualquier contacto accidental.
Nuestras electroválvulas y electroválvulas-piloto están pre-
vistas para funcionar con dispositivos conforme a la norma
EN 61131-2.
RUIDO DE FUNCIONAMIENTO
El ruido de funcionamiento varia según la utilización, el fl uido
y el tipo de material utilizado. El usuario solamente podrá
determinar con precisión el nivel sonoro emitido después de
haber montado el componente en la instalación.
MANTENIMIENTO
El mantenimiento que necesitan los productos ASCO varia
dependiendo de sus condiciones de utilización.
Se recomienda
realizar una limpieza periódica según la naturaleza del fl uido,
las condiciones de funcionamiento y el medio ambiente. Du-
rante la intervención, los componentes deben ser examinados
por si hubera desgastes excesivos.Se dispone de un juego
completo de partes internas como recambio. En el caso de
problemas durante el montaje/mantenimiento o en caso de
duda, contacte con ASCO o sus representantes ofi ciales.
DESMONTAJE
Desmonte las piezas siguiendo el orden indicado en los
dibujos de esta página.
1 - Soltar el clip de sujeción (1), manteniendo una presión
hacia lo bajo, y soltar la bobina (2) (ver códigos bobinas,
páginas siguientes)
2 - Retirar el resorte plano (10).
3 - Desatornille el conjunto tubo-culata (3) y sepárelo del
cuerpo (4).
4 - Saque el conjunto núcleo resorte (5)(6) y la junta de
estanuidad (8).
5 - Limpie o sustituya todas las piezas.
MONTAJE
Monte las piezas en el orden inverso al montaje.
Compruebe que el clip de mantenimiento está correctamente
posicionado, en la bobina (ver dibujo).
La purga debe estar conectada par
a evitar toda polución
interna de la electroválvula.
NOTA :
1 - Lubr
ique la junta de estanquidad (8) y también, ligeramente,
el diámetro exterior del núcleo con un aceite conforme a
las normas AFNOR ISO TR 3498 categoría HL y FC.
2 - Compruebe el correcto apriete del conjunto tubo-culata,
par de apriete (a).
3 - Vuelva a colocar la arandela resorte, la bobina y el clip
de sujeción. Conecte el conjunto del conector.
4 - Después del montaje, haga funcionar la electroválvula
varias veces con el fi n de comprobar que se abren y
cierran correctamente.
5 - Monte los racores de tubería, par de apriete máximo
entre 5 y 7 Nm.
524685-001 524685-001
6 7
Istruzioni di installazione e manutenzione
2
31
2
31
32
IT
Elettrovalvole 3/2 NC-NO-U, a comando diretto
corpo in ottone o acciaio inox 1/8 - 1/4, serie 314
DESCRIZIONE
Serie 314, 3/2 NC-NA:
Elettrovalvole con raccordi fi lettati 1/8-1/4. Corpo in ottone
o acciaio inox.
Bobine: Tutti e 238 i numeri di base sono approvati da UL e
CSA e contrassegnati dagli appropriati logo UL e CSA.
Versioni ATEX:
Vedere “Condizioni particolari per un uso sicuro”.
CONDIZIONI PARTICOLARI PER UN USO SICURO
Per le teste magnetiche secondo ATEX, le istruzioni per l'u-
so contenute nelle istruzioni di installazione specifi che fornite
con il prodotto, devono essere scrupolosamente osservate.
Elettrovalvole con raccordi fi lettati: versioni standard, o
versioni provviste di teste magnetiche, Ex d, Ex e mb, Ex mb,
Ex tc (SG), per l'uso in atmosfere pericolose secondo ATEX-
IECEx.
MONTAGGIO
L'utilizzo dei componenti ASCO deve essere conforme ai
dati tecnici riportati sulla targhetta o nella documentazione del
componente. Per prevenire danni all'apparecchiatura, evitare
che il liquido si solidifi chi a bassa temperatura e rispettare i
limiti di temperatura massimo e minimo.
Eventuali modifi che dell'apparecchiatura sono ammesse
solo se autorizzate dal produttore o da un suo rappresentante.
Prima dell'installazione, depressurizzare il sistema di tuba-
zioni ed eseguire la pulizia interna.
Possibilità di montaggio delle elettrovalvole in tutte le posi-
zioni senza effetti sul funzionamento.
La direzione di fl usso è indicata dalle marcature sul corpo
della valvola e nella documentazione.
Le connessioni di raccordo devono corrispondere alle di-
mensioni indicate sul corpo, sull'etichetta o nella brochure
del prodotto.
ATTENZIONE :
La riduzione delle dimensioni dei raccordi può causare
anomalie di funzionamento.
Per proteggere l’apparecchiatura, installare un fi ltro adatto
al servizio previsto sul lato di entrata, quanto più vicino
possibile al prodotto.
Se si utilizza nastro, pasta, spray o lubrifi cante simile per il
serraggio, evitare l’ingresso di particelle nel sistema.
Utilizzare attrezzi idonei e collocare le chiavi quanto più
vicino possibile al punto di raccordo.
Per evitare danni all’apparecchiatura, NON STRINGERE
ECCESSIVAMENTE le connessioni di raccordo. Applicare
una coppia di serraggio massima da 5 a 7 Nm.
Non utilizzare la valvola o la testa magnetica come.
Le connessioni di raccordo non devono esercitare forza,
coppia o tensione sul prodotto.
CONNESSIONE ELETTRICA
Tutti i collegamenti elettrici devono essere eseguiti esclu-
sivamente da personale addestrato e qualifi cato ed essere
conformi ai regolamenti e alle norme locali.
ATTENZIONE
Prima di qualsiasi intervento, disinserire l’alimentazione
elettrica dei componenti.
Tutti i morsetti a vite devono essere opportunamente serrati
prima della messa in funzione.
I componenti elettrici devono essere messi a terra in confor-
mità alle norme e ai regolamenti locali, secondo la tensione
di alimentazione.
Per garantire la continuità a terra della bobina, verifi care che
questa sia correttamente posizionata durante il montaggio/
lo smontaggio (n. 1).
Il collegamento elettrico dell’apparecchiatura è realizzato
come indicato di seguito:
Connettore disinnestabile secondo ISO 4400 / EN 175301-
803, forma A (Quando la connessione viene effettuata
correttamente e il connettore fornito o selezionato è IP65 o
IP67, l’elettrovalvola avrà il grado di protezione IP65 o IP67).
MESSA IN FUNZIONE
Prima di mettere il circuito sotto pressione, eseguire una
prova elettrica. Nel caso delle elettrovalvole, mettere sotto
tensione la bobina alcune volte e prestare attenzione allo
scatto metallico che indica il funzionamento del solenoide.
FUNZIONE
Le elettrovalvole sono generalmente provviste di bobine
per il funzionamento continuo. Per evitare il rischio di lesioni
personali, non toccare la testa magnetica che può riscal-
darsi durante il normale funzionamento. Se l’elettrovalvola è
facilmente accessibile, l’installatore deve predisporre mezzi
di protezione contro il contatto accidentale.
Le nostre elettrovalvole ed elettrovalvole pilota sono pro-
gettate per funzionare con dispositivi conformi alle norme
EN 61131-2.
EMISSIONE SONORA
L’emissione sonora dipende dall’applicazione, dal fl uido
controllato e dal tipo di apparecchiatura utilizzato. Il livello
sonoro può essere determinato con esattezza solo con la
valvola installata nel sistema.
MANUTENZIONE
La manutenzione dei prodotti ASCO dipende dalle condi-
zioni di servizio. È raccomandata la pulizia periodica la cui
frequenza dipende dai fl uidi utilizzati e dalle condizioni di
servizio. Durante la manutenzione, deve essere verifi cata
l’usura dei componenti. È disponibile una serie completa
di componenti interni da utilizzare come kit di ricambio o di
ricostruzione. In caso di problemi durante l’installazione/la
manutenzione o in caso di dubbio, contattare ASCO o un
suo rappresentante autorizzato.
SMONTAGGIO
Smontare le parti nell'ordine indicato negli schemi sulle pre-
senti Istruzioni di Installazione e Manutenzione
1 - Rimuovere la clip di fi ssaggio (1), facendo pressione
verso il basso, e la bobina (2) (vedere i codici delle bobine
nelle pagine seguenti).
2 - Rimuovere la molla piatta (10).
3 - Svitare il cannotto (3) e separarlo dal corpo (4).
4 - Rimuovere l’unità nucleo mobile/molla (5)(6) e la guar-
nizione (8).
5 - Pulire o sostituire tutte le parti.
RIMONTAGGIO
Rimontare le parti in ordine inverso rispetto allo smontaggio.
Veri care che la clip di fi ssaggio sia correttamente posizionata
sulla bobina (vedere disegno).
Lo scarico deve essere raccordato per evitare la contamina-
zione dell’interno dell’elettrovalvola.
NOTA:
1 - Ingrassare la guarnizione (8) e ricoprire la circonferenza
esterna del nucleo mobile con un leggero strato di lubrifi -
cante a norma AFNOR ISO TR 3498 categorie HL e FC.
2 - Verifi care che il cannotto sia serrato a una coppia (a).
3 - Rimontare la ghiera, la bobina e la clip di fi ssaggio. Collegare
il gruppo connettore.
4 - Dopo il rimontaggio, azionare ripetutamente l’elettroval-
vola per verifi care che le valvole si aprano e chiudano
correttamente.
5 - Rimontare le connessioni di raccordo e serrare a una
coppia massima da 5 a 7 Nm.
Installatie- en onderhoudsinstructies
2
31
2
31
32
NL
3/2 elektromagnetische kleppen NC-NO-U, directwerkend
messing of roestvrijstalen behuizing, 1/8 - 1/4, serie 314
BESCHRIJVING
Serie 314, 3/2 NC-NO-U:
Elektromagnetische kleppen met getapte aansluitingen 1/8-
1/4. Messing of roestvrijstalen.
Spoelen: Alle 238 basisnummers zijn goedgekeurd door UL
& CSA en voorzien van de desbetreffende UL- & CSA-logo's.
ATEX versies:
Zie “Speciale voorwaarden voor veilig gebruik”.
SPECIALE VOORWAARDEN VOOR VEILIG GEBRUIK
Voor magneetkoppen volgens ATEX dienen de gebruiks-
instructies die worden gegeven in de specifi eke Installatie-
instructies die worden meegeleverd met het product strikt te
worden opgevolgd.
Elektromagnetische kleppen met getapte aansluitingen:
Standaardversies of versies voorzien van magneetkoppen,
Ex d, Ex e mb, Ex mb, Ex tc (SG), voor gebruik in explosie-
gevaarlijke ruimten volgens ATEX-IECEx.
MONTAGE
Componenten van ASCO zijn uitsluitend bedoeld om te
worden gebruikt binnen de technische specifi caties zoals
vermeld op de naamplaat of in de documentatie. Om schade
aan de apparatuur te voorkomen, dient u ervoor te zorgen
dat de vloeistof niet stolt bij lagere temperaturen en binnen
de grenzen van de maximum- en minimumtemperatuur blijft.
Wijzigingen aan de apparatuur mogen slechts worden
uitgevoerd na raadpleging van de fabrikant of zijn vertegen-
woordiger.
Voor de installatie dient u het leidingenstelsel te ontluchten
en vanbinnen te reinigen.
De elektromagnetische kleppen kunnen in een willekeurige
positie worden gemonteerd zonder de werking te beïnvloeden.
De stroomrichting wordt aangegeven door markeringen op
de klepbehuizing en in de documentatie.
Buisaansluitingen dienen in overeenstemming te zijn met
de grootte die wordt vermeld op de behuizing, het etiket of
in de productbrochure.
PAS OP:
Het beperken van de aansluitingen kan een onjuiste werking
of storing veroorzaken.
Ter bescherming van de apparatuur dient u in de inlaatzijde
zo dicht mogelijk bij het product een zeef of een fi lter te
installeren die geschikt is voor de betreffende functie.
Indien tape, pasta of spray of een vergelijkbaar smeermid-
del is gebruikt bij het aandraaien dient u te voorkomen dat
deeltjes hiervan het systeem binnendringen.
Gebruik de juiste gereedschappen en plaats steeksleutels
zo dicht mogelijk bij het aansluitpunt.
Om schade aan de apparatuur te voorkomen mag u de
buisaansluitingen NIET TE STRAK AANDRAAIEN. Neem
een maximaal aanhaalkoppel in acht van 5 tot 7 Nm.
Gebruik de klep of magneetkop niet als hefboom.
Buisaansluitingen mogen geen enkele kracht, wringing of
druk uitoefenen op het product.
ELEKTRISCHE AANSLUITING
Alle elektrische aansluitingen mogen uitsluitend door opge-
leid en gekwalifi ceerd personeel worden uitgevoerd en dienen
in overeenstemming te zijn met de plaatselijke voorschriften
en normen.
PAS OP:
Schakel vóór iedere ingreep de elektrische stroom uit om de
stroomtoevoer naar de componenten te verbreken.
Alle schroefklemmen dienen naar behoren te zijn aangedraaid
voordat ze in werking worden gesteld.
Afhankelijk van de voltage dienen elektrische componen-
ten te worden geaard volgens de plaatselijke normen en
voorschriften.
Om continue aarding van de spoel te garanderen dient u
ervoor te zorgen dat deze juist gepositioneerd is tijdens de
montage/demontage (nr. 1).
De apparatuur is als volgt elektrisch aangesloten:
Uitneembare connector volgens ISO 4400 / EN 175301-
803, formulier A (Mits correct aangesloten en indien de
gebruikte (geleverde of gekozen) connector IP65- of IP67-
geklassifi ceerd is, heeft de magneetklep bescherming IP65
of IP67).
INWERKINGSTELLING
Voer, alvorens het circuit onder druk te zetten, een elektri-
citeitstest uit. Bij elektromagnetische kleppen activeert u de
spoel een paar keer en hoort u een metaalachtige ‘’klik’ die
erop duidt dat de elektromagneet werkt.
FUNCTIE
De meeste elektromagnetische kleppen zijn uitgerust met
spoelen voor continubedrijf. Om het risico van persoonlijk
letsel te voorkomen de magneetkop niet aanraken. Deze kan
namelijk heet worden bij normaal gebruik. Als de elektromag-
netische klep gemakkelijk toegankelijk is, dient de installateur
te zorgen voor bescherming tegen onbedoeld contact.
Onze magneetventielen en stuurventielen zijn ontwikkeld
om te functioneren met apparatuur die voldoet aan de
EN 61131-2 norm.
GELUIDSEMISSIE
De emissie van geluid is afhankelijk van de toepassing,
de vloeistof en het type apparatuur dat wordt gebruikt. Het
precieze geluidsniveau kan slechts worden bepaald door
de gebruiker die de klep in zijn systeem heeft geïnstalleerd.
ONDERHOUD
Het onderhoud van producten van ASCO is afhankelijk van
de gebruiksvoorwaarden. Het wordt aanbevolen periodiek
te reinigen volgens een tijdschema dat afhankelijk is van de
gebruikte vloeistoffen en de gebruiksvoorwaarden. Tijdens
het onderhoud dienen de componenten te worden gecon-
troleerd op bovenmatige slijtage. Een complete set interne
onderdelen is beschikbaar als reserveonderdelenkit of revi-
siekit. Als zich een probleem voordoet tijdens de installatie of
het onderhoud of in geval van twijfel kunt u contact opnemen
met ASCO of de erkende vertegenwoordigers.
DEMONTAGE
Demonteer de onderdelen in de volgorde die wordt aange-
geven in de afbeeldingen in deze Installatie- en onderhouds-
instructies
1 - Verwijder de bevestigingsclip (1), blijf druk omlaag
uitoefenen, en de spoel (2) (zie spoelcodes op de
volgende pagina's).
2 - Verwijder de vlakke veer (10).
3 - Schroef de kern-buisunit los (3) en scheid deze van de
behuizing (4).
4 - Verwijder de kern/veerunit (5)(6) en de afdichting (8).
5 - Reinig of vervang alle onderdelen.
HERMONTAGE
Hermonteer de onderdelen in omgekeerde volgorde als de
demontage.
Controleer of de borgclip juist is gepositioneerd op de spoel
(zie tekening).
De uitlaat dient aangesloten te zijn om verontreiniging van
de binnenkant van de elektromagnetische klep te voorkomen.
OPMERKING:
1 - Smeer de afdichting (8) en coat de buitenomtrek van de
kern licht met een smeermiddel conform de norm AFNOR
ISO TR 3498 categorie HL en FC.
2 - Controleer of de kern-buisunit goed is vastgedraaid met
een koppel (A).
3 - Monteer nu de veerring, de spoel en de bevestigingsclip.
Sluit de steker weer aan.
4 - Activeer na de hermontage de elektromagnetische klep
een paar keer om er zeker van te zijn dat de kleppen naar
behoren open- en dichtgaan.
5 - Hermonteer de buisaansluitingen en draai deze vast met
een maximumkoppel van 5 tot 7 Nm.
524685-001 524685-001
8 9
Installasjons- og vedlikeholdsinstrukser
2
31
2
31
32
NO
3/2 magnetventiler NC-NO-U, direkte betjente med hus av messing
eller rustfritt stål, 1/8 - 1/4, serie 314
BESKRIVELSE
Serie 314, 3/2 NC-NO-U:
Magnetventiler med gjengede 1/8-1/4 koplinger. Hus av
messing eller rustfritt stål.
Spoler: Alle 238 grunnleggende tallene er UL- og CSA-
godkjent og henholdsvis merket med de riktige UL- og CSA-
logoene.
ATEX versions:
Se ”Spesielle vilkår for sikker bruk”:
SPESIELLE VILKÅR FOR SIKKER BRUK
For spoleoperatører i henhold til ATEX, må bruksanvisnin-
gen gitt i de spesifi kke installasjonsinstruksene som kom-
mer sammen med produktet strengt overholdes.
Magnetventiler med gjengede koplinger: Standard versjo-
ner eller versjoner utstyrt med spoleoperatører, Ex d, Ex e mb,
Ex mb, Ex tc (SG), for bruk i eksplosive atmosfærer i henhold
til ATEX-IECEx.
MONTERING
ASCO-komponenter er kun beregnet på bruk innenfor de
tekniske karakteregenskapene som er spesifi sert på navne-
platen eller i dokumentasjonen. For å unngå skade på utstyret
må du sørge for å forhindre at væsken går over til fast form
ved lave temperaturer og holder seg innenfor grensene for
maksimal- og minimumstemperatur.
Modifi kasjoner av utstyret må kun gjøres etter rådføring med
produsenten eller hans representant.
r installering, må trykket reduseres og rørsystemet ren-
gjøres innvendig.
Magnetventilene kan monteres i enhver stilling uten at det
påvirker driften.
Strømningsretningen angis av merker på ventilhuset og i
dokumentasjonen.
rkoplinger må være i samsvar med størrelsen angitt på
huset, merket eller i produktbrosjyren.
OBS!
Reduksjon av koblingene kan føre til feil bruk eller svikt.
For å beskytte utstyret bør du installere en sil eller et fi lter som
passer for betjening av inntaket så nært produktet som mulig.
Hvis det brukes tape, glassfuss, spray eller tilsvarende
smøremiddel for stramming, må du unngå at det kommer
partikler inn i systemet.
Bruk riktig verktøy og plasser nøkler så nær tilkoblingspunktet
som mulig.
For å unngå skade på utstyret må rørkoblingene IKKE
TREKKES TIL FOR STRAMT. Bruk et maksimalt tiltrekk-
ningsmoment på 5 til 7 Nm.
Ikke bruk ventilen eller spoleoperatøren som vektstang.
rkoblinger må ikke legge noen vekt, moment eller belast-
ning på produktet.
ELEKTRISK TILKOBLING
Alle elektriske koplinger må bare gjøres av faglig kvalifi -
sert personale og må være i samsvar med lokale regler og
standarder.
OBS!
r eventuelle inngrep må du slå av strømmen slik at kom-
ponentene slås av.
Alle skrueklemmer må strammes skikkelig før de tas i bruk.
Avhengig av spenningen må elektriske komponenter være
jordet i henhold til lokale standarder og forskrifter.
For å sørge for god jording av spolen må du sørge for at den
er korrekt posisjonert under montering/demontering (nr. 1).
Utstyret er elektrisk tilkoplet som følger:
s kopling i henhold til ISO 4400 / EN 175301-803, form
A (Ved riktig tilkobling og når (den leverte eller valgte)
konnektoren i bruk har IP65- eller IP67 spesifi kasjon, har
solenoidventilen IP65- eller IP67- vern).
SETTE I DRIFT
r kretsen settes under trykk må du utføre en elektrisk test.
For magnetventiler skal du energisere spolen et par ganger
og høre et metallklikk som signal på at elektromagneten virker.
FUNKSJON
De fl este spoleventiler er utstyrt med spoler beregnet på
kontinuerlig drift. For å redusere risikoen for personskade må
man ikke berøre spoleoperatøren, som kan bli varm under
normale driftsforhold. Hvis magnetventilen er lett tilgjengelig,
må installatøren sette opp vern som forhindrer tilfeldig kontakt.
Våre solenoid- og pilotventiler er utformet til å fungere
sammen med enheter som er i samsvar med standard
EN-61131-2.
STØY
Støynivået avhenger av bruksområdet, væsken og typen ut-
styr som brukes.yaktig fastsettelse av støynivået kan bare
gjøres av brukeren som har ventilen installert i sitt system.
VEDLIKEHOLD
Vedlikehold av ASCO-produkter avhenger av betjenings-
forholdene. Periodisk rengjøring anbefales. Tidspunktene for
dette vil avhenge av væskene som brukes og servicefor-
holdene. Under service bør komponentene kontrolleres for
overdreven slitasje. Et fullstendig sett med interne deler er
tilgjengelig som et reservedels- eller ombyggingssett. Hvis
det oppstår et problem under installasjon/vedlikehold eller
hvis du er i tvil må du ikke nøle med å ta kontakt med ASCO
eller dennes autoriserte representanter.
DEMONTERING
Demonter delene i den rekkefølgen som angis på snittene i
disse installasjons- og vedlikeholdsinstruksene
1 - Fjern festeklemmen (1), oppretthold trykket nedover,
og spolen (2) (se spolekoder på følgende sider).
2 - Fjern den fl ate fjæren (10).
3 - Skru av kjernerørdelen (3) og skill den fra huset (4).
4 - Fjern kjerne/fjær-enheten (5)(6) og tetningen (8).
5 - Rengjør eller skift ut alle deler.
REMONTERING
Monter komponentene i omvendt rekkefølge fra demontering.
rg for at festeklemmen er korrekt posisjonert på spolen
(se tegning).
Utløpet må være tilkoplet for å forhindre forurensning av
innsiden av magnetventilen.
MERK:
1 - Ha fett på tetningen (8) og påfør den ytre omkretsen av
kjernen med et smøremiddel som er i henhold til standarden
AFNOR ISO TR 3498 kategoriene HL og FC.
2 - rg for at kjerne-rør-enheten trekkes korrekt til med et
moment (a).
3 - Sett den fl ate fjæren, spolen og festeklemmen tilbake på
plass. Koble til tilkoblingsmonteringen.
4 - Etter remontering skal du bruke magnetventilen fl ere
ganger for å være sikker på at ventilene åpnes og lukkes
som de skal.
5 - Sett rørkoblinger sammen på nytt og stram på et maksimalt
dreiemoment på 5 til 7 Nm.
Installations- och underhållsinstruktioner
2
31
2
31
32
SE
3/2 solenoidventiler NC-NO-U, direktstyrda
ventilkropp i mässing eller rostfri stål, 1/8 - 1/4, serie 314
BESKRIVNING
Serie 314, 3/2 NC-NO-U:
• Solenoidventiler med gängad 1/8-1/4 koppling. Kropp i
mässing eller rostfri stål
Spolar: Alla de 238 basnumren är UL- och CSA-godkända
och märkta med tillämpliga UL- och CSA-logotyper.
ATEX-versioner:
Se “Särskilda villkor för säker användning”.
SÄRSKILDA VILLKOR FÖR SÄKER ANVÄNDNING
För solonoidoperatörer till ATEX, är det viktigt att strikt följa
användningsinstruktionerna som levereras med produkten.
Solenoidventiler med gängad koppling: Standard versio-
ner eller versioner försedda med solenoidoperatörer, Ex d,
Ex e mb, Ex mb, Ex tc (SG), för användning i explosiva om-
givningar enligt ATEX-IECEx.
MONTERING
ASCO-komponenter är enbart avsedda för användning enligt
de tekniska egenskaper som specifi cerats på namnplattan
eller i dokumentation. Skydda utrustningen mot skador, låt
inte vätskan stelna vid låg temperatur och se till att den hålls
inom maximum och minimum temperaturgränser.
Utrustningen får enbart modifi eras med tillverkarens eller
en representants uttryckliga medgivande.
Före installationen ska trycket i ledningarna kopplas bort
och rengöras invändigt.
Solenoidventilerna kan monteras i valfri position utan att
detta inverkar på funktionen.
Flödesriktningen anges med markeringar på ventilkroppen
och i dokumentationen.
Rörkopplingarna ska göras enligt storleken som står angiven
på kroppen, etiketten eller produktbladet.
VARSAMHET:
Att minska antalet kopplingar kan förorsaka fel eller bristande
funktion.
För att skydda utrustningen ska en lämplig sil eller ett fi lter
installeras för intaget och så nära produkten som möjligt.
Var försiktig så att inga partiklar kommer in i systemet vid
användning av tejp, fett, sprej eller liknande smörjmedel vid
åtdragningen.
Använd rätt verktyg och placera alltid skiftnyckeln så nära
kopplingspunkten som möjligt.
Undvik att skada utrustningen: DRA INTE ÅT RÖRKOPPLINGARNA
FÖR HÅRT. Observera det maximala vridmomentet på 5 till 7 Nm.
Använd aldrig ventilen eller solenoidoperatören som en
hävstång.
Rörkopplingar får inte utgöra en forcerande belastning på
produkten.
ELEKTRISK ANSLUTNING
Alla elektriska anslutningar ska utföras av behörig elektriker
och i enlighet med gällande lokala standarder och bestäm-
melser.
VARSAMHET:
Innan något utförs ska all strömförsörjning till komponenterna
kopplas bort.
Alla elektriska skruvkontakter ska dras åt enligt anvisningarna
innan produkten tas i bruk.
Beroende på strömspänning, ska elektriska komponenter
jordas enligt lokala normer och regler.
För att försäkra om kontinuerlig jordning av spolen, se till att
den placeras korrekt vid isättning/urtagning (nr. 1).
Utrustningen har följande elektriska koppling:
Löstagbar koppling i enlighet med ISO 4400 / EN 175301-803,
formulär A (Vid korrekt koppling och när (den levererade eller
valda) kopplingen är IP65- eller IP67-märkt, är solenoidven-
tilen skyddad enligt typ IP65 eller IP67).
DRIFTSSÄTTNING
Utför en elektrisk test innan kretsen sätts under tryck. Vid
användning av solenoidventiler, slå till spolen ett antal gång-
er och lägg märke till ett metalliskt klickljud vilket indikerar
att solenoiden har aktiverats.
FUNKTION
De fl esta solenoidventiler har spolar för kontinuerlig drift.
För att förebygga risk för person- eller materialskada får
solenoidoperatören inte vidröras då den kan bli mycket varm
vid normal drift. Om solenoidventilen är lätt att komma åt ska
installatören förse med skydd mot oavsiktlig kontakt.
Våra solenoidventiler och pilotventiler är konstruerade för
användning med enheter som överensstämmer med EN
61131-2-standarden.
BULLERNIVÅ
Bullernivån är beroende på tillämpningen, vätsketyp och typ
av utrustning. Den exakta bullernivån kan bara fastställas av
användaren på platsen där ventilen installerats.
UNDERHÅLL
Underhållet av ASCO-produkter är beroende på driftförhål-
landena. Regelbunden rengöring rekommenderas, intervallet
är beroende på vätskan som används och driftförhållandena.
Under driften ska komponenterna kontrolleras på slitage. En
komplett uppsättning invändiga delar fi nns som reservdel
eller reservdelssats. Om ett problem uppstår vid installation/
underhåll eller vid frågor, ta då gärna kontakt med ASCO
eller en auktoriserad representant.
ISÄRTAGNING
Ta av delarna i den ordningsföljd som anges i fi gurerna i dessa
Installations- och underhållsinstruktioner
1 - Ta bort fästklämman (1), bibehåll ett nedåtriktat tryck,
och spolen (2) (se spolkoder på följande sidor).
2 - Ta bort den platta fjädern (10).
3 - Skruva loss kärnröret (3) och tar ut det ur ventilkroppen (4).
4 - Ta bort kärnan/fjäderenheten (5)(6) och o-ringen (8).
5 - Rengör eller byt ut alla delar.
HOPSÄTTNING
Sätt ihop delarna in omvänd ordningsföljd.
Se till att klämman sitter på spolen ordentligt (se ritning).
Utblåset måste kopplas så att inga föroreningar kan komma
in i solenoidventilen.
OBS!
1 - Smörj packningen (8) och förse kärnans yttre omkrets med
ett tunt skikt fett enligt AFNOR ISO TR 3498 kategoriema
HL och FC.
2 - Se till att kärnrörsenheten spänns fast ordentligt enligt
vridmoment (a).
3 - Sätt tillbaka den platta fjädern, spolen och fästklämman.
Anslut kopplingsenheten.
4 - Efter hopsättningen, testa solenoidventilens funktion fl era
gånger för att försäkra att ventilerna öppnar och stänger
som de ska.
5 - Koppla ihop rörledningarna och spänn fast enligt det
maximala vridmomentet på 5 till 7 Nm.
524685-001 524685-001
10 11
Asennus- ja huolto-ohjeet
2
31
2
31
32
FI
3/2-solenoidiventtiilit NC-NO-U, suoratoiminen runko messinkiä tai
ruostumatonta terästä, 1/8 - 1/4, sarja 314
KUVAUS
Sarja 314, 3/2 NC-NO-U:
Solenoidiventtiilit, joissa on 1/8-1/4-kierreliitännät. Runko
messinkiä tai ruostumatonta terästä.
Kelat: Kaikki 238 perusnumeroa ovat UL- ja CSA-hyväksyt-
tyjä, ja ne on merkitty asianomaisilla UL:n ja CSA:n logoilla.
ATEX-direktiivin mukaiset versiot:
Katso kohta Turvalliset käyttöolosuhteet.
TURVALLISET KÄYTTÖOLOSUHTEET
ATEX-direktiivin mukaisten solenoidikäyttölaitteiden muka-
na toimitettuja asennusohjeita on ehdottomasti noudatettava.
Solenoidiventtiilit, joissa on -kierreliitännät: Standardin-
mukaiset versiot tai versiot, joissa on solenoidikäyttölaitteet,
Ex d, Ex e mb, Ex mb, Ex tc (SG), tarkoitettu käytettäväksi
räjähdysvaarallisissa ympäristöissä ATEX-IECEx-standardin
mukaisesti.
ASENTAMINEN
ASCO-osat on tarkoitettu käytettäväksi vain tyyppikilvessä
tai asiakirjoissa määriteltyjen teknisten ominaisuuksien
mukaisesti. Jotta laitteisto ei vahingoittuisi, varmista, että
nestemäinen aine ei kiinteydy alhaisissa lämpötiloissa ja
että ympäröivä lämpötila ei ylitä suositeltua vähimmäis- tai
enimmäislämpötilaa.
Tuotteisiin saa tehdä muutoksia vain valmistajan tai valmis-
tajan edustajan luvalla.
Poista putkista paine ja puhdista sisäpuoli ennen asentamista.
Solenoidiventtiilit voidaan asentaa mihin asentoon tahansa.
Virtauksen suunta on merkitty venttiilin runkoon ja käyttö-
ohjeisiin.
Putkiliitäntöjen on oltava yhdenmukaiset rungossa, tarrassa
tai tuote-esitteessä olevien kokomerkintöjen kanssa.
TÄRKEÄÄ:
Liitäntöjen vähentäminen saattaa aiheuttaa toimintahäiriöitä.
Suojaa laitteisto asentamalla käyttötarkoitukseen sopiva sihti
tai suodatin aukon puolelle mahdollisimman lähelle tuotetta.
Jos kiristämisessä käytetään teippiä, massaa, suihketta
tai vastaavaa voiteluainetta, vältä hiukkasten pääsemistä
järjestelmään.
Käytä sopivia työkaluja ja aseta vääntöavaimet mahdollisim-
man lähelle liitäntäkohtaa.
ÄLÄ KIRISTÄ PUTKILIITÄNTÖJÄ LIIKAA laitevaurion vält-
tämiseksi. Huomioi kiristysmomentti 5–7 Nm.
Älä käytä venttiiliä tai solenoidikäyttölaitetta vipuna.
Putkiliitäntöjen ei tule kohdistaa tuotteeseen voimaa, vääntöä
tai rasitusta.
SÄHKÖLIITÄNTÄ
Sähköliitännät on annettava pätevien henkilöiden tehtäväksi
paikallisten standardien ja määräysten mukaisesti.
TÄRKEÄÄ:
Katkaise osien virransyöttö ennen asennuksen aloittamista.
Kaikki ruuviliitokset on kiristettävä kunnolla ennen käyttöä.
Sähköliitännät on maadoitettava paikallisten standardien ja
säännösten ja jännitteen mukaisesti.
Varmista käämin maadoitus tarkistamalla, että käämi on
sijoitettu oikein asennuksen/purkamisen aikana (nro 1).
Laitteiston sähköliitännät:
Irrotettava liitin EN 175301-803, form A (Asianmukaisessa
liitännässä tai käytettävän (mukana tulleen tai valitun) liitti-
men luokituksen ollessa IP65 tai IP67 solenoidiventtiilillä on
IP65- tai IP67-suojaus).
YTTÖÖNOTTO
Tee sähkömittaukset ennen piirin paineistamista. Johda sole-
noidiventtiileihin muutaman kerran jännite. Metallinen napsah-
dus merkitsee, että solenoidi toimii.
TOIMINTA
Useimmissa solenoidiventtiileissä on jatkuvaa toimintaa
varten suunnitellut käämit. Henkilövahingon ehkäisemiseksi
älä kosketa solenoidikäyttölaitetta, joka voi kuumentua
normaaleissa käyttöolosuhteissa. Jos solenoidiventtiiliin on
vaivaton päästä käsiksi, asentajan on järjestettävä riittävä
suojaus tahattoman kosketuksen estämiseksi.
Magneetti- ja pilottiventtiilimme on suunniteltu toimimaan
standardin EN 61131-2 mukaisten laitteiden kanssa.
ÄÄNET
Venttiilistä kuuluvat äänet määräytyvät käyttösovelluksen,
virtaavan aineen ja käytetyn laitetyypin mukaan. Vain käyttäjä
voi määrittää äänitason tarkasti, kun venttiili on asennettu
järjestelmään.
HUOLTO
ASCO-tuotteiden huolto riippuu käyttöolosuhteista. Säännöl-
linen puhdistaminen, jonka ajoitus riippuu nesteistä ja käyt-
töolosuhteista, on suositeltavaa. Huollon aikana on tarkistet-
tava, ovatko osat kuluneet liikaa. Varaosa- ja korjaussarjana
on saatavana täydellinen sarja sisäosia. Mikäli asennuksen/
huollon yhteydessä tulee ongelmia tai mikäli olet epävarma,
ota yhteys ASCOiin tai valtuutettuun edustajaan.
PURKAMINEN
Pura osat näissä asennus- ja huolto-ohjeissa ilmoitetussa
järjestyksessä.
1 - Irrota kiinnityssinkilä (1), ylläpidä painetta alaspäin, ja
käämi (2) (katso käämin koodit "LIITÄNTÄ"-sivulta).
2 - Irrota lattajousi (10).
3 - Ruuvaa irti ydinputkiyksikkö () ja irrota se rungosta (4).
4 - Poista ydin-/jousiyksikkö (5)(6) ja tiiviste (8).
5 - Puhdista tai vaihda kaikki osat.
KOKOAMINEN
Kokoa osat uudelleen käänteisessä järjestyksessä.
Varmista, että kiinnityssinkilä on oikeassa asennossa kää-
missä (katso kuva).
Poistosuojuksilla on estettävä solenoidiventtiilin sisäosien
likaantuminen.
HUOM.
1 - Rasvaa tiiviste (8) ja voitele ytimen ulkokehä kevyesti
standardin AFNOR ISO TR 3498 luokkien HL ja FC
mukaisella voiteluaineella.
2 - Varmista, että ydinputkiyksikkö on kiristetty kunnolla
kiristysmomenttiin (a).
3 - Asenna lattajousi, käämi ja kiinnityssinkilä takaisin
paikalleen. Yhdistä liitinyksikkö.
4 - Käytä solenoidiventtiiliä monta kertaa uudelleenkokoami-
sen jälkeen, jotta voit varmistaa, että venttiilit avautuvat
ja sulkeutuvat kunnolla.
5 - Kokoa uudelleen putkiliitännät ja kiristä ne enintään 5–7
Nm:n kiristysmomenttiin.
Installations- og vedligeholdelsesvejledning
2
31
2
31
32
DK
3/2 magnetventiler NC-NO-U med direkte betjening
og hus af messing eller rustfrit stål, 1/8 - 1/4, serie 314
BESKRIVELSE
Serie 314, 3/2 NC-NO-U:
Magnetventiler med 1/8-1/4 gevindforbindelser. Hus af mes-
sing eller rustfrit stål.
Spoler: Alle 238 basisnumre er UL- og CSA-godkendte og
mærket med de pågældende UL- og CSA-logoer.
ATEX-versioner:
Se “Særlige krav til sikker brug”.
SÆRLIGE KRAV TIL SIKKER BRUG
For så vidt angår magnetstyreenheder til ATEX skal in-
struktionerne i den installationsvejledning, der følger med
produktet, følges nøje.
Magnetventiler med gevindforbindelser: Almindelige versio-
ner eller versioner, der er forsynet med magnetstyreenheder, Ex
d, Ex e mb, Ex mb, Ex tc (SG), til anvendelse til ATEX-IECEx i
eksplosionsfarlige omgivelser.
MONTERING
ASCO-komponenter er kun beregnet til brug under de
tekniske vilkår, der er beskrevet på typepladen eller i doku-
mentationen. For at undgå beskadigelse af udstyret skal det
sikres, at væsken ikke kan størkne ved lave temperaturer, og
at de gældende grænser for maksimum- og minimumtempe-
ratur overholdes.
Ændringer på udstyret må kun foretages efter samråd med
producenten eller dennes repræsentanter.
Udløs trykket i rørsystemet og rens det indvendigt før instal-
lationen.
Magnetventilerne kan monteres i alle positioner, uden at
det påvirker driften.
Strømningsretningen er angivet med markeringer på ven-
tilhuset og i dokumentationen.
rforbindelser skal stemme overens med den størrelse,
der er angivet på huset, mærkningen eller produktets ind-
lægsseddel.
FORSIGTIG:
Reducering af forbindelserne kan forårsage forkert funktion
eller fejl.
Til beskyttelse af udstyret kan der i indløbssiden så tæt på
produktet som muligt installeres en si eller et fi lter, der er
egnet til formålet.
Pas på, at der ikke kommer partikler ind i systemet, hvis der
bruges tape, pasta, spray eller et lignende smøremiddel i
forbindelse med tilspændingen.
Brug det korrekte værktøj og brug skruenøglerne så tæt på
samlingspunktet som muligt.
For at undgå beskadigelse af udstyret må rørforbindelserne
IKKE OVERSPÆNDES. Et maksimalt tilspændingsmoment
på 5 til 7 Nm skal overholdes.
Brug ikke ventilen eller magnetstyreenheden som løftegreb.
rforbindelserne må ikke udøve nogen kraft, vridningsmo-
ment eller belastning på produktet.
ELEKTRISK INSTALLATION
Alle elektriske tilslutninger må kun foretages af personale med
erfaring og uddannelse til formålet og skal foretages i over-
ensstemmelse med de lokale bestemmelser og standarder.
FORSIGTIG:
Sluk for strømmen til komponenterne, inden der foretages
nogen form for indgriben.
Alle skrueklemmer skal være spændt ordentligt inden
ibrugtagning.
De elektriske komponenter skal være jordforbundne i over-
ensstemmelse med lokale standarder og bestemmelser og
alt afhængigt af spændingen.
Af hensyn til spolens jordkontinuitet skal det sikres, at den
placeres korrekt under montering/demontering (nr. 1).
Udstyret forbindes elektrisk som følger:
Aftagelig konnektor til ISO 4400 / EN 175301-803, type A
(Efter korrekt tilslutning og når det - medfølgende eller valgte
- stik er kapslingsklasse IP65 eller IP67, vil solenoideventilen
have IP65- eller IP67-beskyttelse).
START AF DRIFT
Udfør en elektrisk test, inden der bliver sat tryk på kredsløbet.
Ved magnetventiler aktiveres spolen nogle få gange, og der
lyttes efter et metalklik, som betyder, at magneten fungerer.
FUNKTION
De fl este magnetventiler er udstyret med spoler, der er
konstrueret til kontinuerlig drift. For at forebygge personskader
må magnetstyreenheden, som kan blive meget varm under
normale driftsbetingelser, ikke berøres. Hvis der er let adgang
til magnetventilen, skal installatøren sørge for, at det ikke er
muligt at berøre den ved et uheld.
Vores solenoideventiler og pilotventiler er beregnet til at
fungere sammen med enheder, der opfylder standarderne i
henhold til EN 61131-2.
LY D
Udsendelsen af lyd afhænger af brugen, væsken og den
type udstyr, der anvendes. En nøjagtig fastlæggelse af lyd-
niveauet kan kun foretages af den bruger, der har ventilen
installeret i sit system.
VEDLIGEHOLDELSE
Vedligeholdelsen af ASCO-produkter afhænger af brugsbe-
tingelserne. Regelmæssig afrensning anbefales; hvor ofte af-
hænger af de anvendte væsker og brugsbetingelserne. Under
vedligeholdsarbejdet skal komponenterne ses efter for unor-
malt kraftig slitage. Et komplet sæt med de indvendige dele
kan fås som reservedelssæt eller genopbygningssæt. Kontant
ASCO eller en autoriseret repræsentant, hvis der opstår pro-
blemer under installation/vedligeholdelse eller i tvivlstilfælde..
DEMONTERING
Adskil delene i den rækkefølge, der er angivet på tegningerne
i denne Installations- og vedligeholdelsesvejledning.
1 - Fjern fastholdelsesklipsen (1), fasthold trykket nedad,
og spolen (2) (se spolekoder på følgende sider).
2 - Fjern den fl ade fjeder (10).
3 - Skru kernerørsenheden (3) af og adskil den fra huset (4).
4 - Fjern kerne/fjederenhed (5)(6) og pakning (8).
5 - Rengør eller udskift alle dele.
REMONTERING
Saml delene igen i omvendt rækkefølge af demonteringen.
Kontrollér, at holdeklemmen er korrekt anbragt på spolen
(se tegningen).
Udløbet skal være tilsluttet for at forhindre kontaminering af
indersiden af magnetventilen.
BEMÆRK:
1 - Smør pakningen (8) og læg et tyndt lag smøremiddel på
den udvendige omkreds af kernen. Dette smøremiddel
skal opfylde standarden AFNOR ISO TR 3498, kategori
HL og FC.
2 - rg for, at kernerørsenheden er korrekt tilspændt med
et tilspændingsmoment (A).
3 - Sæt den fl ade fjeder, spolen og fastholdelsesklipsen på
plads igen. Forbind stikenheden.
4 - Kør magnetventilen fl ere gange efter remontering for at
sikre, at ventilerne åbner og lukker korrekt.
5 - Saml rørforbindelserne igen og spænd dem ved et mak-
simalt tilspændingsmoment på 5 til 7 Nm.
524685-001 524685-001
12 13
Instruções de instalação e manutenção
2
31
2
31
32
PT
Válvulas solenóides 3/2 NC-NO-U, corpo de aço inoxidável ou latão,
directas, 1/8 - 1/4, séries 314
DESCRIÇÃO
Série 262, 3/2 NC-NO-U:
Válvulas solenóides com ligações de rosca de 1/8-1/4. Corpo
em latão ou aço inoxidável.
Bobinas: Todos os 238 números básicos estão aprovados pela
UL & CSA e marcados com os logótipos UL & CSA adequados.
Versões ATEX:
Consulte as “Condições especiais para utilização segura”.
CONDIÇÕES ESPECIAIS PARA UTILIZAÇÃO SEGURA
Para operadores de solenóide para ATEX, as instruções de
utilização fornecidas nas instruções de instalação específi cas
fornecidas com o produto têm de ser cumpridas.
Válvulas solenóides com ligações de rosca: Versões
standard ou versões equipadas com operadores de sole-
nóide, Ex d, Ex e mb, Ex mb, Ex tc (SG), para utilização em
atmosferas explosivas para ATEX-IECEx.
MONTAGEM
Os componentes da ASCO devem ser utilizados apenas
de acordo com as características técnicas especifi cadas na
placa de identifi cação ou na documentação. Para evitar danos
no equipamento, certifi que-se de que impede o líquido de
solidifi car a baixas temperaturas e que permanece dentro
dos limites de temperatura mínimos e máximos.
As modifi cações ao equipamento só podem ser efectuadas
após consulta ao fabricante ou ao seu representante.
Antes da instalação, despressurize o sistema de tubos e
limpe o interior.
As válvulas solenóides podem ser montadas em qualquer
posição sem afectar o funcionamento.
A direcção do caudal é indicada pelas marcas no corpo da
válvula e na documentação.
As ligações dos tubos têm de estar de acordo com o tamanho
indicado no corpo, etiqueta ou no folheto do produto.
ATENÇÃO:
A redução das ligações pode provocar um funcionamento
inadequado ou uma avaria.
Para protecção do equipamento, instale uma rede ou um
ltro adequado para a assistência relacionada com o lado
de entrada o mais junto possível do produto.
Quando utilizar fi ta adesiva, pasta, spray ou um lubrifi cante
idêntico para apertar, evite a entrada de partículas no sistema.
Utilize as ferramentas adequadas e coloque as chaves de
bocas o mais junto possível do ponto de ligação.
Para evitar danos no equipamento, NÃO APERTE
EXCESSIVAMENTE as ligações do tubo. Cumpra um binário
de aperto máximo de 5 a 7 Nm.
Não utilize a válvula nem o operador de solenóide como
uma alavanca.
As ligações do tubo não devem exercer qualquer força,
binário ou esforço no produto.
LIGAÇÃO ELÉCTRICA
Todas as ligações eléctricas têm de ser efectuadas por
pessoal especializado e qualifi cado e têm de estar de acordo
com as normas e os regulamentos locais.
ATENÇÃO:
Antes de efectuar qualquer intervenção, desligue a corrente
eléctrica para desactivar os componentes.
Todos os terminais dos parafusos têm de ser apertados
correctamente antes de serem utilizados.
Dependendo da voltagem, os componentes eléctricos têm
de ser ligados à terra de acordo com os regulamentos e as
normas locais.
Para garantir a continuidade de terra da bobina, certifi que-se
de que está posicionada correctamente durante a montagem/
desmontagem (nº 1).
O equipamento é ligado electricamente da seguinte forma:
Conector amovível para ISO 4400 / EN 175301-803, forma A
(Quando a conexão é correctamente efectuada e quando o
conector (fornecido ou seleccionado) usado é IP65 ou IP67,
o grau de protecção da electroválvula será IP65 ou IP67).
COLOCAÇÃO EM FUNCIONAMENTO
Antes de pressurizar o circuito, efectue um teste eléctrico.
No caso das válvulas solenóides, estimule a bobina algumas
vezes e observe um clique metálico que signifi ca que a so-
lenóide está a funcionar.
FUNCIONAMENTO
A maior parte das válvulas de solenóide está equipada
com bobinas concebidas para trabalho contínuo. Para evitar
lesões corporais, não toque no operador de solenóide que
pode fi car quente em condições de funcionamento normais.
Se a válvula solenóide tiver acesso fácil, o instalador deve
utilizar equipamento de protecção para evitar qualquer
contacto acidental.
As nossas electroválvulas e electroválvulas-piloto foram
concebidas para funcionar com os dispositivos conforme a
norma EN 61131-2.
EMISSÃO DE SOM
A emissão de som depende da aplicação, fl uído e tipo de
equipamento utilizado. A determinação exacta do nível de
som só pode ser efectuada pelo utilizador com a válvula
instalada no sistema.
MANUTENÇÃO
A manutenção dos produtos da ASCO depende das condições
de serviço. A limpeza periódica é recomendada e o momento
da limpeza depende dos fl uidos utilizados e das condições de
assistência. Deve verifi car se os componentes têm um desgaste
excessivo durante a assistência. Um conjunto completo de
peças internas está disponível como um kit de peças sobres-
selentes ou reconstruídas. Se surgir algum problema durante
a instalação/manutenção ou no caso de dúvidas, contacte a
ASCO ou um representante autorizado.
DESMONTAGEM
Desmonte as peças pela ordem indicada nas vistas destas
Instruções de I&M
1 - Remova a braçadeira de fi xação (1),manter a pressão
para baixo e a bobina (2) (ver o códigos das bobinas nas
páginas seguintes).
2 - Remover a mola plana (10).
3 - Desaparafuse o tubo do núcleo (3) e separe-o do corpo (4).
4 - Remova o núcleo/mola (5)(6) e o vedante (8).
5 - Limpe ou substitua todas as peças.
MONTAGEM
Monte as peças pela ordem inversa de desmontagem.
Certifi que-se de que a braçadeira de fi xação está correcta-
mente colocada na bobina (ver desenho).
A saída tem de estar ligada para impedir a contaminação do
interior da válvula solenóide.
NOTA:
1 - Lubrifi que o vedante (8) e revista a circunferência exterior
do núcleo com um lubrifi cante em conformidade com a
norma AFNOR ISO TR 3498 categorias HL e FC.
2 - Certifi que-se de que o tubo do núcleo está apertado
correctamente com um binário (a).
3 - Substituir a mola plana, a bobina e o clip de retenção.
Ligar o conector.
4 - Depois da montagem, opere a válvula solenóide várias
vezes para garantir que as válvulas abrem e fecham
correctamente.
5 - Monte das ligações dos tubos e aperte com um binário
máximo de 5 a 7 Nm.
Οδηγίες εγκατάστασης και συντήρησης
2
31
2
31
32
GR
3/2 ηλεκτρομαγνητικές βαλβίδες NC-NO-U, με απευθείας χειρισμό
σώμα από ορείχαλκο ή ανοξείδωτο ατσάλι, 1/8 - 1/4, σειρά 314
ΠΕΡΙΓΡΑΦΗ
Έκδοση/ 314, 3/2 NC-NO-U:
Ηλεκτρομαγνητικές βαλβίδες με κοχλιωτές συνδέσεις 1/8-1/4.
Σώμα από ορείχαλκο ή ανοξείδωτο ατσάλι.
Πηνία: Και τα 238 βασικά νούμερα έχουν εγκριθεί από τα UL
& CSA και φέρουν σήμανση με τα δέοντα λογότυπα των UL
& CSA.
Τύποι συσκευής σύμφωνοι με:
ΔείτεΕιδικές συνθήκες για ασφαλή χρήση”.
ΕΙΔΙΚΕΣ ΣΥΝΘΗΚΕΣ ΓΙΑ ΑΣΦ
ΑΛΗ ΧΡΗΣΗ
Όπως προβλέπεται από την οδηγία ATEX σχετικά με ηλε-
κτρομαγνητικές κεφαλές, πρέπει να τηρούνται αυστηρά οι
οδηγίες χρήσης που συνοδεύουν τις συγκεκριμένες Οδηγίες
εγκατάστασης που συνοδεύουν το προϊόν.
Ηλεκτρομαγνητικές βαλβίδες με κοχλιωτές συνδέσεις:
Οι βασικές εκδόσεις με βαθμό προστασίας ή οι εκδόσεις που
έχουν εξοπλιστεί με ηλεκτρομαγνητικές κεφαλές, Ex d, Ex e mb,
Ex mb, Ex tc (SG), για χρήση σε εκρήξιμη ατμόσφαιρα σύμ-
φωνα με την οδηγία ATEX-IECEx.
ΣΥΝΑΡΜΟΛΟΓΗΣΗ
Τα εξαρτήματα ASCO προορίζονται για χρήση μόνο σε
τεχνικά χαρακτηριστικά που αναγράφονται στην ετικέτα ή στα
συνοδευόμενα έγγραφα. Για να αποφύγετε τυχόν βλάβη του
εξοπλισμού, φροντίστε να αποφύγετε τη στερεοποίηση του
υγρού σε χαμηλές θερμοκρασίες και βεβαιωθείτε ότι τηρείτε
τα όρια μέγιστης κα
ι ελάχιστης θερμοκρασίας.
Οποιεσδήποτε μετατροπές στον εξοπλισμό μπορούν να
πραγματοποιηθούν μόνο αφού συμβουλευτείτε τον κατασκευ-
αστή ή τον εμπορικό αντιπρόσωπό του.
Πριν την εγκατάσταση, αποσυμπιέστε το σύστημα σωληνώ-
σεων και καθαρίστε εσωτερικά.
Οι ηλεκτρομαγνητικές βαλβίδες μπορούν να τοποθετηθούν
σε οποιαδήποτε θέση χωρίς να επηρεάζουν τη λειτουργία.
Η κατεύθυνση της ροής υπ
οδεικνύεται από τις σημάνσεις στο
σώμα της βαλβίδας και στα συνοδευτικά έγγραφα.
Οι συνδέσεις της σωλήνωσης θα πρέπει να είναι σύμφωνες
με το μέγεθος που υποδεικνύεται στο σώμα, την ετικέτα και
στο φυλλάδιο του προϊόντος.
ΠΡΟΣΟΧΗ :
Ο περιορισμός των συνδέσεων μπορεί να οδηγήσει σε
λανθασμένο χειρισμό ή κακή λειτουργία.
Για την προστασία του εξοπλισμού, τοποθετήστε μία κατάλληλη
για τη συγκεκριμένη εργασία σήτα ή φίλτρο, στην πλευρά
εισόδου και όσο το δυνατόν πιο κοντά στο προϊόν.
Εάν χρησιμοποιήσετε ταινία, αλοιφή, σπρέι ή παρόμοιο
λιπαντικό κατά τη σύσφιξη, αποφύγετε την είσοδο σωματιδίων
στο σύστημα.
Χρησιμοποιείτε τα κατάλληλα εργαλεία και τοποθετήστε τα
κλειδιά όσο το δυνατόν πιο κοντά στο σημείο σύνδεσης.
Για να αποφύγετε τυχόν βλάβες στον εξοπλισμό, ΜΗ ΣΦΙΞΕΤΕ
ΠΟΛΥ τις συνδέσεις των σωλήνων. Τηρήστε τη μέγιστη ροπή
σύσφιγξης από 5 έως 7 Nm.
Μη χρησιμοποιείτε τη βαλβίδα ή την ηλεκτρομαγνητική
κεφαλή ως μοχλό.
Οι συνδέσεις σωλήνων δεν πρέπει να ασκούν δύναμη, ροπή
ή πίεση στο προϊόν.
ΗΛΕΚΤΡΙΚΗ ΣΥΝΔΕΣΗ
Όλες οι ηλεκτρικές συνδέσεις πρέπει να γίνονται μόνο από
εξειδικευμένο και εκπαιδευμένο προσωπικό και θα πρέπει να
ακ
ολουθούν τους τοπικούς κανονισμούς και πρότυπα.
ΠΡΟΣΟΧΗ:
Πριν από οποιαδήποτε επέμβαση, διακόψτε την ηλεκτρική
τροφοδοσία για να απενεργοποιήσετε τα εξαρτήματα.
Όλοι οι ακροδέκτες των βιδών πρέπει να έχουν σφιχτεί σωστά
προτού τεθούν σε λειτουργία.
Ανάλογα με την τάση, τα ηλεκτρικά εξαρτήματα πρέπει να
έχουν γειωθεί σύμφωνα με τα τ
οπικά πρότυπα και κανονισμούς.
Για να διασφαλίσετε συνέχεια γης του πηνίου, βεβαιωθείτε ότι
το πηνίο έχει τοποθετηθεί σωστά κατά την συναρμολόγηση/
αποσυναρμολόγηση. 1).
Ο εξοπλισμός έχει συνδεθεί ηλεκτρικά ως εξής:
Αποσπώμενος συνδετήρας ISO 4400 / EN 175301-803,
μορφή A (Με μία σωστή σύνδεση και όταν ο (χορηγούμενος
ή επιλεγμένος) σύνδεσμος που χρησιμοποιείτε είναι προδι-
αγραφών IP65- ή -IP67, η ηλεκτροβαλβίδα θα είναι διαθέτει
προστ
ασία προδιαγραφών IP65 ή IP67).
ΔΟΚΙΜΑΣΤΙΚΗ ΛΕΙΤΟΥΡΓΙΑ
Προτού αποσυμπιέσετε το κύκλωμα, πραγματοποιήστε ένα
ηλεκτρολογικό έλεγχο. Στην περίπτωση των ηλεκτρομαγνητι-
κών βαλβίδων, ενεργοποιήστε το πηνίο μερικές φορές ώστε
να ακούσετε ένα μεταλλικόκλικπου σημαίνει ότι η ηλεκτρο-
μαγνητική κεφαλή λειτουργεί.
ΛΕΙΤΟΥΡΓΙΑ
Οι περισσότερες ηλεκτρομαγνητικές βαλβίδες είναι εξ
ο-
πλισμένες με πηνία για λειτουργία υπό διαρκή τάση. Για
να αποφύγετε τον κίνδυνο τραυματισμού, μην αγγίζετε την
ηλεκτρομαγνητική κεφαλή η οποία μπορεί να υπερθερμαν-
θεί ακόμα και υπό φυσιολογικές συνθήκες λειτουργίας. Εάν
υπάρχει εύκολη πρόσβαση στην ηλεκτρομαγνητική βαλβίδα,
ο υπεύθυνος για την τοποθέτηση θα πρέπει να λάβει την
κατάλληλη προστασία κα
τά της ακούσιας επαφής.
Οι ηλεκτροβαλβίδες και οι πιλοτικές βαλβίδες μας είναι
σχεδιασμένες έτσι ώστε να συνεργάζονται με συσκευές που
συμμορφώνονται με το πρότυπο EN 61131-2.
ΕΚΠΟΜΠΗ ΗΧΟΥ
Η εκπομπή ήχου διαφέρει ανάλογα με την εφαρμογή, το
υγρό και τον τύπο του εξοπλισμού που χρησιμοποιείται. Ο
χρήστης δεν μπορεί να πραγματοποιήσει ακριβή καθορισμό
του επιπέδου ήχου παρά μόνο αφού εγκαταστήσει τη βαλβίδα
στο σύστημά του.
ΣΥΝΤΗΡΗΣΗ
Η συντήρηση των προϊόντων ASCO εξαρτάται από τις συνθή-
κες λειτουργίας. Συνιστάται περιοδικός καθαρισμός, το χρονικό
διάστημα του οποίου θα εξαρτηθεί από τα χρησιμοποιούμε-
να υγρά και της συνθήκες λειτουργίας. Κατά τη συντήρηση,
πρέπει να πραγματοποιείται έλεγχος των εξαρτημάτων για
υπερβολική φθορά. Διατίθεται πλήρες σύνολο εσωτερικών
εξαρτημάτων ως ανταλλακτικά ή εξαρτήματα ανακατασκευής.
Εάν προκύψει κάποιο πρόβλημα κατά την εγκατάσταση/συ-
ντήρηση ή εάν παρουσιαστούν απορίες, επικοινωνήστε με την
ASCO ή με τους εξουσιοδοτημένους αντιπροσώπους της.
ΑΠΟΣΥΝΑΡΜΟΛΟΓΗΣΗ
Αποσυναρμολογήστε τα εξαρτήματα στη σειρά που υποδει-
κνύουν οι εικόνες στις Οδηγίες Εγκατάστασης και Συντήρησης.
1 - Αφαιρέστε το έλασμα συγκράτησης (1), διατηρήστε την
καθοδική πίεση, και το πηνίο (2) (βλ. κωδικοί πηνίο σε
επόμενες σελίδες).
2 - Αφαιρέστε το πλακέ ελατήριο (10).
3 - Ξεβιδώστε τη μονάδα πυρήνα-αγωγού (3) και διαχωρίστε
την από το σώμα (4).
4 - Ξεβιδώστε τη μονάδα πυρήνα/ελατήριο (5)(6) και το
στεγανοποιητικό παρέμβυσμα (8).
5 - Καθαρίστε ή αντικαταστήστε όλα τα εξαρτήματα.
ΕΠΑΝΑΣΥΝΑΡΜΟΛΟΓΗΣΗ
Επανασυναρμολογήστε όλα τα εξαρτήματα στην αντίθετη σειρά
που ακολουθήθηκε κατά τη στη συναρμολόγηση.
Βεβαιωθείτε ότι το ελατήριο συγκράτησης είναι σωστά τοπο-
θετημένο στο πηνίο (βλέπε σχεδιάγραμμα).
Ο αγωγός εκπομπής αερίων πρέπει είναι συνδεδεμένος
προκειμένου να αποφευχθεί η μόλυνση των εσωτερικών
τμημάτων της ηλεκτρομαγνητικής βαλβίδας.
ΣΗΜΕΙΩΣΗ:
1 - Αλείψτε με γράσο το στεγανοποιητικό παρέμβυσμα (8) και
καλύψτε ελαφρά την εξωτερική περιφέρεια του πυρήνα με
λιπαντικό που είναι σύμφωνο με τις κατηγορίες HL και FC
του προτύπου AFNOR ISO TR 3498.
2 - Βεβαιωθείτε ότι η μονάδα πυρήνα-αγωγού έχει σφιχτεί
επαρκώς με ροπή (a).
3 - Αντικαταστήστε το πλακέ ελατήριο, το πηνίο και το έλασμα
συγκράτησης. Συνδέστε το συγκρότημα του συνδέσμου.
4 - Μετά την επανασυναρμολόγηση, θέστε σε λειτουργία πολλές
φορές την ηλεκτρομαγνητική βαλβίδα για να βεβαιωθείτε
ότι οι βαλβίδες ανοίγουν και κλείνουν καλά.
5 - Επανασυναρμολογήστε τις συνδέσεις σωλήνωσης και
σφίξτε με Μέγιστη ροπή από 5 έως 7 Nm.
524685-001 524685-001
14 15
Návod na instalaci a údržbu
2
31
2
31
32
CZ
Solenoidové ventily NC-NO-U 3/2, přímo ovládané. mosazné nebo
nerezové ocelové tělo, 1/8 - 1/4, série 314
POPIS
Série 314, 3/2 NC-NO-U:
Solenoidové ventily se šroubeními velikosti 1/8-1/4. Tělo z
mosaze nebo z nerezové ocele.
ATEX verze:
Cívky: Každé z 238 základních čísel je schváleno normou
UL a CSA a označeno odpovídajícími štítky UL a CSA.
Viz “Speciální podmínky pro bezpečné použití”.
SPECIÁLNÍ PODMÍNKY PRO BEZPEČNÉ POUŽITÍ
Pro solenoid operátory ve verzi ATEX musí být návod na
použití uveden ve speci ckém Návodě na Údržbu dodaném
s výrobkem striktně dodržován.
Solenoidové ventily se šroubeními: Standard verze ane-
bo verze vybavené solenoid operátory, Ex d, Ex e mb, Ex mb,
Ex tc (SG), pro použití ve výbušných atmosférách ve verzi
ATEX-IECEx.
MONTÁŽ
Komponenty ASCO jsou určené pro použití jen v souladu
s technickými charakteristiky speci kovanými na továrním
štítku anebo v dokumentaci. Aby se zabránilo poškození
zařízení, ujistěte se, že jste zabránili kapalině dostat se do
tuhnoucí fáze při nízkých teplotách a že se pohybujete v rámci
maximálního a minimálního teplotního intervalu.
Modi kace na zařízení můžou být vykonány jen po konzultaci
s výrobcem anebo jeho zástupcem.
Před instalací snižte tlak v potrubním systému a vnitřně ho
vyčistěte.
Solenoidové ventily můžou být namontovány v jakékoliv
pozici bez ovlivněčinnosti.
Směr toku je uvedený značeními na těle ventilu a v doku-
mentaci.
Potrubní přípojky musí být v souladu s velikostí uváděnou
na těle, štítku anebo v prospektu výrobku.
UPOZORNĚNÍ :
Snížení připojení může způsobit nesprávný provoz a fun-
gování.
Pro ochranu vybavení nainstalujte čistič anebo ltr vhodný
pro provoz na straně přítoku, co nejblíže k výrobku.
V případě použití pásky, lepidla, spreje anebo obdobního
maziva při upínání, zabraňte částicím vniknout do systému.
Použijte vhodné nástroje a umístíte klíče co nejblíže k bodu
připojení.
Aby se zabránilo poškození zařízení, NEPŘET
AHUJTE
potrubní přípojky. Dodržujte maximální utahovací moment
od 5 do 7 Nm.
Nepoužívejte ventil anebo solenoid operátora jako páku.
Potrubní přípojky by neměli na výrobek vyvíjet žádnou silu,
točivý moment ani pnutí
ELECTRICKÉ PŘIPOJENÍ
Všechny elektrické připojení musí být vykonané jen vyško-
leným a kvali kovaným personálem a musí být v souladu s
místními nařízeními a standardy.
UPOZORNĚNÍ :
Před jakýmkoliv zásahem vypněte elektrický proud pro
uvedení komponentů mimo napětí.
Všechny šroubové svorky musí být před uvedením do provozu
řádně utáhnuté předtím.
V závislosti od elektrického napětí musí být elektrické
komponenty uzemněné v souladu s místními standardy a
nařízeními.
Pro zajištění kontinuity uzemnění vinutí se ujistěte, že je v
průběhu montáže/demontáže správně umístěné (č. 1).
Zařízení je elektricky zapojeno tímto způsobem:
Odpojitelný konektor na ISO 4400 / EN 175301-803, form
A (Při správném připojení a s použitím (dodaného nebo
zvoleného) konektoru, který je určený pro IP65 nebo IP67,
bude mít elektromagnetický ventil ochranu IP65 nebo IP67).
UVEDENÍ DO PROVOZU
Před natlakovaním okruhu vykonejte elektrický test. V pří-
padě solenoid ventilů několikrát uveďte vinutí pod napětí a
všimněte si kovové kliknutí označující provoz solenoidu.
FUNKCE
Většina solenoid ventilů je vybavených vinutím pro nepřetr-
žitý provoz. Aby se zabránilo riziku zranění osob, nedotýkejte
se solenoid operátora, který může při běžných provozních
podmínkách dosahovat vysokých teplot. Když je solenoid
ventil lehce přístupný, musí montér zhotovit ochranu proti
náhodnému kontaktu.
Naše elektromagnetické a řídící ventily jsou vyrobeny tak,
aby fungovaly se zařízeními vyhovujícími standardu EN
61
131-2.
EMISE HLUKU
Emise hluku závisí od aplikace, kapalině a typu použitého
zařízení. Přesné určení hladiny hluku může být vykonáno jen
uživatelem, který má ventil už nainstalovaný v jeho systému.
ÚDRŽBA
Údržba výrobků ASCO závisí od provozních podmínek. Do-
poručuje se pravidelné čištění, časování kterého bude závislé
od použitých kapalin a od provozních podmínek. Během
servisu musí být komponenty zkontrolované pro nadměrné
opotřebení. Kompletní sada vnitřních součástí je k dispozici
jako náhradní díly anebo jako sada pro přestavbu. Když
nastane problém během instalace/údržby anebo v případě
pochybností prosím kontaktujte ASCO anebo autorizovaného
zástupce.
DEMONTÁŽ
Demontujte součástky v pořadí označeném na pohledech v
tomto Návode na instalaci a údržbu
1 - Odstraňte příchytku (1), stále tlačte dolů, a vinutí (2) (viz
kódy vinutí na následujících stranách).
2 - Odstraňte pružnou podložku (10).
3 - Odšroubujte jaderní potrubní jednotku (3) a oddělte jí od
těla (4).
4 - Odstraňte jednotku jádro/pružina (5)(6) a těsnění (8).
5 - Vyčistěte anebo vyměňte všechny součástky.
SMONTOVÁNÍ
Smontujte součástky v opačném pořadí demontáže.
Ujistěte se, že příchytka je ve správné pozici na vinutí (viz.
nákres).
Výfuk musí být zapojen, aby se tak předešlo znečištění vnitřku
solenoid ventilu.
POZNÁMKA:
1 - Namažte těsnění (8) a jemně natřete vnější obvod jádra
mazivem odpovídajícím standardu AFNOR ISO TR 3498
kategorie HL a FC.
2 - Ujistěte se, že jednotka jaderního potrubí je řádně utažená
na utahovací moment (A).
3 - Nainstalujte pružnou podložku, vinutí a příchytku. Připojte
sestavu konektoru.
4 - Po smontování uveďte solenoid ventil do provozu, aby
jste se tak ujistili, že se ventily řádně otevírají a zavírají.
5 - Smontujte potrubní přípojky a utáhněte na maximální
utahovací moment od 5 do 7 Nm.
Instrukcje dotyczące instalacji i konserwacji
2
31
2
31
32
PL
Zawory elektromagnetyczne NC-NO-U 3/2, do bezpośredniego użycia
korpus mosiężny lub ze stali nierdzewnej, 1/8 - 1/4 seria 314
OPIS
Seria 314, 3/2 (2-drogowe) NC-NO-U :
Zawory elektromagnetyczne z przyłączem gwintowanym
1/8-1/4. Korpus mosiężny lub ze stali nierdzewnej.
Cewki: Wszystkie 238 numerów podstawowych jest zatwier-
dzonych przez UL i CSA oraz oznaczonych odpowiednim
logo UL i CSA.
Wersje ATEX:
Patrz „Specjalne warunki bezpiecznego używania”
SPECJALNE WARUNKI BEZPIECZNEGO UŻYWANIA
Do sterowania solenoidu zgodnie z dyrektywą ATEX, trzeba
ściśle przestrzegać instrukcji użytkowania zawartych w szcze-
łowych Instrukcjach dotyczących Instalacji dostarczonych
wraz z tym produktem.
Zawory elektromagnetyczne z przyłączem gwintowym:
Wersje o
klasie ochrony lub wersje ze sterowaniem solenoidu,
Ex d, Ex e mb, Ex mb, Ex tc (SG)
, do użytku w środowiskach
zagrożonych wybuchem zgodnie z dyrektywą
ATEX-IECEx
(dotyczącą potencjalnych wydzielin wybuchowych).
MONTAŻ
Podzespoły ASCO są przeznaczone do użytku jedynie zgodnie
z charakterystyką techniczną podaną na tabliczce znamionowej
lub w dokumentacji. Aby uniknąć uszkodzenia produktu należy
nie dopuścić do zestalenia się płynu w niskich temperaturach
i nie dopuścić do przekroczenia maksymalnej ani minimalnej
temperatury działania.
Mody kacji urządzenia można dokonać jedynie po konsultacji
z producentem lub jego przedstawicielem.
Przed instalacją należy rozhermetyzować instalację rurową
i wyczyścić od środka.
Zawory elektromagnetyczne mogą być zamontowane w
dowolnym ustawieniu bez wpływu na ich działanie.
Kierunek przepływu wskazuje oznakowanie na korpusie
zaworu i opis w dokumentacji.
Przyłącza rur muszą być zgodne z wielkością podaną na
korpusie zaworu, tabliczce znamionowej lub w ulotce produktu.
UWAGA:
Skracanie przyłączy może spowodować nieprawidłowe
działanie lub awarię techniczną.
W celu ochrony produktu, należy w części wlotowej tak blisko
produktu jak to możliwe, zamontować sitko lub ltr odpowiedni
do przeznaczenia produktu.
Jeśli taśma, pasta do gwintów, spray lub podobna substancja
nawilżająca jest używana podczas dokręcania, należy uniknąć
dostania się ich drobinek do systemu.
Należy używać właściwych narzędzi i umieścić klucze tak
blisko miejsca łączenia jak to możliwe.
Aby uniknąć uszkodzenia produktu, NIE WOLNO
PRZEKRĘCAĆ przyłączy rur. Maksymalny moment obrotowy
dokręcenia powinien wynieść 5 do 7 Nm.
Nie należy używać zaworu ani sterowania solenoidu jako
dźwigni.
Przyłącza rur nie powinny oddziaływać jakąkolwiek siłą,
przykładać momentu obrotowego ani naciskać na produkt.
ŁĄCZA ELEKTRYCZNE
Wszystkie instalacje elektryczne muszą być wykonywane
wyłącznie przez wyszkolonych i wykwali kowanych pracow-
ników i spełniać wymogi miejscowych przepisów i norm.
UWAGA:
Przed jakąkolwiek ingerencją, należy odłączyć dopływ prądu
elektrycznego do wszystkich podzespołów.
Wszystkie śruby muszą być prawidłowo dokręcone przez
przywróceniem produktu do pracy.
W zależności od napięcia, podzespoły elektryczne muszą
być uziemione zgodnie z miejscowymi normami i przepisami.
Aby zapewnić ciągłość uziemienia cewki, należy upewnić się,
że została ona właściwie umieszczona podczas montażu/
demontażu (nr 1).
Podłączenie elektryczne produktu jest następujące:
W
ymienne przyłącze do ISO 4400 / EN 175301-803, form A
(Pod warunkiem poprawnego podłączenia oraz gdy (dostar-
czone lub wybrane) zastosowane złącze ma klasę ochrony
IP65 lub IP67, zawór elektromagnetyczny będzie miał także
klasę ochrony IP65 lub IP67).
URUCHOMIENIE
Przed zahermetyzowaniem obwodu należy przeprowadzić
test elektryczny. W przypadku zaworów elektromagnetycz-
nych należy zasilić cewkę parokrotnie aż do usłyszenia me-
talicznego dźwięku wskazującego na działanie solenoidu.
DZIAŁANIE
Większość zaworów elektromagnetycznych jest wyposażona
w cewki przeznaczone do pracy ciągłej. Aby uniknąć niebezpie-
czeństwa obrażeń, nie należy dotykać solenoidu, który w nor-
malnych warunkach eksploatacji może się mocno nagrzewać.
Jeśli zawór elektromagnetyczny jest łatwo dostępny, monter
powinien zabezpieczyć się przed przypadkowym kontaktem.
Nasze zawory elektromagnetyczne i zawory pilotowe są
przystosowane do współpracy z urządzeniami zgodnymi z
normą EN 61131-2.
WYDAWANIE DŹWIĘKU
Wydawanie dźwięku zależy od zastosowania, płynu i rodza-
ju użytego urządzenia. Dokładne określenie poziomu głośno-
ści może być przeprowadzone jedynie przez użytkownika już
po zainstalowaniu zaworu w systemie.
KONSERWACJA
Konserwacja produktów ASCO zależy od warunków eksplo-
atacji. Zaleca się okresowe czyszczenie, którego częstotliwość
jest uzależniona od rodzaju stosowanego płynu i warunków
eksploatacji. Podczas serwisowania należy sprawdzić, czy
podzespoły nie uległy nadmiernemu zużyciu. Kompletny ze-
staw wewnętrznych części jest dostępny jako zestaw części
zamiennych albo zestaw naprawczy. W razie wystąpienia pro-
blemu w trakcie instalacji/konserwacji lub w razie wątpliwości,
należy skontaktować się z rmą ASCO lub jej autoryzowanym
przedstawicielem.
DEMONTAŻ
Należy zdemontować części w kolejności wskazanej na
schematach zamieszczonych w niniejszej Instrukcji dotyczącej
instalacji i konserwacji.
1 - Wyjąć zacisk mocujący (1), utrzymując ciśnienie do dołu,
oraz cewkę (2) (patrz kody cewek na następnych stronach).
2 - Wyjąć płaską sprężynę (10).
3 - Odkręć tuleję trzpienia ruchomego (3) i oddziel ją od
korpusu (4)
4 - Usuń rdzeń ruchomy/sprężynę zaworową (5)(6) i uszczelkę
(8)
5 - Wyczyść lub wymień wszystkie części.
PONOWNY MONTAŻ
Ponownie zamontuj części w kolejności odwrotnej niż podczas
demontażu.
Należy upewnić się, że zacisk jest właściwie umieszczony na
cewce (patrz rysunek).
Wylot musi być podłączony, aby uniknąć zanieczyszczenia
wewnętrznej części zaworu elektromagnetycznego.
UWAGA:
1 - Nasmaruj uszczelkę (8) i lekko pokryj zewnętrzny obwód
rdzenia ruchomego substancją nawilżającą zgodną z normą
AFNOR ISO TR 3498 w kategoriach HL i FC.
2 - Należy upewnić się, że tuleja trzpienia ruchomego jest
odpowiednio dokręcona przy momencie obrotowym (A).
3 - Wymienić płaską sprężynę, cewkę i zacisk mocujący.
Podłączyć zespół złącza.
4 - Po ponownym montażu, sprawdź kilkakrotnie zawór elek-
tromagnetyczny, aby upewnić się, że zawory otwierają się
i zamykają prawidłowo.
5 - Ponownie podłączyć instalację rurową i dokręcić przy
momencie obrotowym od 5 do 7 Nm.
524685-001 524685-001
16
Telepítési és karbantartási utasítások
2
31
2
31
32
HU
3/2-es NC-NO-U mágnesszelepek, közvetlen
működtetésű sárgaréz vagy
rozsdamentes acél test,
1/8 -
1/4, 263/263-os sorozat
LEÍRÁS
263/263-os sorozat, 3/2 NC-NO-U:
Mágnesszelep 1/8-1/4 menetes csatlakozókkal. Sárgaréz
vagy rozsdamentes acél test.
Tekercsek: Mind a 238 alapszám UL és CSA által jóváha-
gyott, és a megfelelő UL és CSA logókkal látták el őket.
ATEX változatok:
Lásd “A biztonságos használat speciális feltételei” című részt.
A BIZTONSÁGOS HASZNÁLAT SPECIÁLIS FELTÉTELEI
Az ATEX szolenoidok esetében szigorúan követni kell a
termékhez adott speciális telepítési utasításokat.
Mágnesszelepek menetes csatlakozókkal: Szabvány vé-
dettségi fokozatú változatok vagy működtető mágnestekerccsel
felszerelt változatok, Ex d, Ex e mb, Ex mb, Ex tc (SG), az
ATEX-IECEx szerinti robbanásveszélyes légterekben való
használathoz.
SZERELÉS
Az ASCO alkatrészek csak az adattáblán vagy a dokumen-
tációban meghatározott műszaki jellemzők tartományában
használhatók. A berendezés sérülésének elkerülése
érdekében akadályozza meg a folyadék alacsony hőfokon
történő megszilárdulását, és tartsa a maximális és minimális
hőmérsékleti határértékek között.
A berendezést csak a gyártóval vagy annak képviselőjével
való konzultáció után módosítható.
A telepítés előtt nyomásmentesítse a csőrendszert és
végezzen belső tisztítást.
A mágnesszelepek bármilyen helyzetben felszerelhetők, a
helyzet nem befolyásolja a működést.
Az áramlás irányát a szeleptesten és a dokumentációban
látható jelzések mutatják.
A csőcsatlakozóknak meg kell felelniük a testen vagy a
címkén jelzett, illetve a termékismertető füzetben megadott
méreteknek.
VIGYÁZAT:
A csatlakozó méretének csökkentése helytelen működést
vagy meghibásodást okozhat.
A berendezés védelmének érdekében telepítsen egy a szer-
vizeléshez alkalmas szitát vagy szűrőt a bemeneti oldalra,
minél közelebb a termékhez.
Ha a rögzítésnél szalagot, kenőcsöt, sprayt vagy hasonló
kenőanyagot használ, ügyeljen rá, hogy annak részecskéi
ne kerüljenek be a rendszerbe.
Használjon megfelelő eszközöket, és a csavarkulcsokat a
lehető legközelebb helyezze a csatlakozási ponthoz.
A berendezés sérülésének elkerülése érdekében NE HÚZZA
MEG TÚL ERŐSEN a csőcsatlakozókat. A meghúzó nyo-
maték nem haladhatja meg az 5-7 Nm-t.
Ne használja a szelepet vagy a mágnestekercset emelő-
karként.
A csőcsatlakozók nem gyakorolhatnak erőt, nyomatékot
vagy terhelést a termékre.
ELEKTROMOS CSATLAKOZTATÁS
Minden elektromos csatlakoztatást csak szakképzett sze-
mélyzet végezhet, a helyi rendeleteknek és szabványoknak
megfelelően.
VIGYÁZAT:
Bármilyen beavatkozás előtt kapcsolja le a feszültséget az
alkatrészekről.
A használatba helyezés előtt minden szorítócsavart jól meg
kell húzni.
Az elektromos alkatrészeket a feszültségtől függően megfe-
lelően földelni kell, a helyi szabványok és rendeletek szerint.
A tekercs folytonos földelése érdekében azt megfelelően
helyezze el az összeszereléskor/szétszereléskor (1. ábra).
A berendezés elektromos csatlakoztatása:
Levehető EN 175301-803, form A (Megfelelő csatlakoztatás
és a (mellékelt vagy kiválasztott) IP65 vagy IP67 besorolású
csatlakozó használata esetén a szolenoid szelep IP65 vagy
IP 67 védelmi besorolással fog rendelkezni).
ÜZEMBE HELYEZÉS
Mielőtt nyomás alá helyezi az áramkört, végezzen elektromos
tesztelést. Mágnesszelepek esetén kapcsolja be néhányszor
a tekercset, és gyelje meg a fémes kattanást, amely az elekt-
romágnes működését jelzi.
MŰKÖDTETÉS
A legtöbb mágnesszelep folyamatos működésre tervezett
tekerccsel van ellátva. A személyi sérülések elkerülése
érdekében ne érintse meg szolenoidot, mert az normál üzemi
körülmények közt is felforrósodhat. Ha a mágnesszelep
könnyen megközelíthető helyen van, a telepítőnek védelmet
kell biztosítania a véletlen érintéssel szemben.
Szolenoid szelepeink és vezérlőszelepeink úgy vannak
megtervezve, hogy az EN 61131-2 szabványnak megfelelő
termékekkel együttműködjenek.
HANGKIBOCSÁTÁS
A hangkibocsátás az alkalmazástól, a folyadéktól és a hasz-
nált berendezés típusától függ. A hangerő szintjének pontos
meghatározását csak a felhasználó végezheti el a szelep
rendszerbe való beszerelése után.
KARBANTARTÁS
Az ASCO termékek karbantartása az üzemi körülményektől
függ. Javasolt rendszeres tisztítást végezni, melynek gyakori-
sága a használt folyadéktól és az üzemi körülményektől függ.
A szervizelés során ellenőrizze az alkatrészek kopásának
mértékét. A belső alkatrészek teljes készlete beszerezhető
pótalkatrész- vagy átszerelő készletben. Ha a szerelés/kar-
bantartás közben probléma adódik, vagy kétségei merülnek
fel, lépjen kapcsolatba az ASCO céggel vagy annak hivatalos
képviselőivel.
SZÉTSZERELÉS
Az alkatrészeket a telepítési és karbantartási utasításokban
látható ábráknak megfelelő sorrendben kell szétszerelni.
1 - Folyamatosan lefelé nyomva távolítsa el a tartókapcsot (1)
és a tekercset (2) (a tekercskódok a következő oldalakon).
2 - Távolítsa el a lapos rugót (10).
3 - Csavarozza ki a központi csőegységet (3) és válassza
el a testtől (4).
4 - Távolítsa el a központi/rugó egységet (5)(6) és a tömítést (8).
5 - Tisztítson meg vagy cseréljen ki minden alkatrészt.
ISMÉTELT ÖSSZESZERELÉS
Az alkatrészeket a szétszereléssel ellentétes sorrendben
kell összeszerelni.
Ügyeljen rá, hogy a tartókapocs megfelelő helyzetben kerüljön
a tekercsre (lásd az ábrát).
A kiömlőnyílást úgy kell csatlakoztatni, hogy az elektromágnes
tekercsének belseje ne szennyeződhessen.
MEGJEGYZÉS:
1 - Zsírozza meg a tömítést (8), a mag külső peremét pedig
enyhén kenje meg az AFNOR ISO TR 3498 szabvány HL
és FC kategóriáinak megfelelő kenőanyaggal.
2 - Ügyeljen rá, hogy a központi csőegység meghúzása a
megfelelő meghúzó nyomatékkal (A).
3 - Helyezze vissza a lapos rugót, a tekercset és a tartókapcsot.
Szerelje vissza a csatlakozószerelvényt.
4 - Az ismételt összeszerelés után kapcsolja be néhányszor
a mágnesszelepet vagy, és ellenőrizze, hogy a szelepek
megfelelően nyílnak és záródnak-e.
5 - Szerelje vissza a csőcsatlakozókat, és húzza meg azokat
legfeljebb 5-7 Nm meghúzó nyomatékkal.
17
Общие указания по установке и обслуживанию
2
31
2
31
32
RU
Электромагнитные 3/2 NC-NO-U с прямым приводом,
медный или стальной корпус, серия 2314 1/8 - 1/4
ОПИСАНИЕ
Серия 314, 3/2 NC-NO-U:
Электромагнитные клапаны с резьбовыми соединениями
1/8-1/4. Медный корпус или корпус из нержавеющей стали.
Катушки: Все 238 основных чисел утверждены UL & CSA
и помечены соответствующим логотипом UL & CSA.
Исполнения ATEX:
См. “Особые условия безопасного использования”.
ОСОБЫЕ УСЛОВИЯ БЕЗОПАСНОГО ИСПОЛЬЗОВАНИЯ
Для электромагнитных исполнительных устройств стан-
дарта ATEX необходимо строго соблюдать указания по ис-
пользованию, приведенные в соответствующей инструкции
по установке, прилагаемой к изделию.
Электромагнитные клапаны с резьбовыми соединени-
ями: стандартные модели или модификации с электромаг-
нитным исполнительным устройством для использования
во взрывоопасных средах маркируются префиксом Ex d,
Ex e mb, Ex mb
, Ex tc (SG)
, согласно требованиям ATEX.
СБОРКА
Компоненты ASCO предназначены для использования толь-
ко с соблюдением технических характеристик, указанных на
паспортной табличке или в документации. Чтобы предотвра-
тить повреждение оборудования, не допускайте замерзания
жидкостей при низких температурах и соблюдайте максималь-
ные и минимальные температурные ограничения.
Модификация оборудования допускается только после кон-
сультаций с изготовителем или его представителем.
Перед установкой сбросьте давление в трубопроводе и
очистите его внутренние поверхности.
Электромагнитные клапаны можно устанавливать в любом
положении, это не влияет на их работоспособность.
Направление потока указано метками на корпусе клапана
и в документации.
Трубные соединения должны быть выполнены в соответ-
ствии с размерами, указанными на корпусе, наклейке или в
брошюре с описанием изделия.
ОСТОРОЖНО:
Уменьшение длины соединения может стать причиной сбоев
в работе или неисправности.
Для защиты оборудования установите подходящую сетку
или фильтр на впуске как можно ближе к изделию.
Если при затяжке используется лента, паста, спрей или
аналогичные смазки, не допускайте попадания их в систему.
Используйте подходящие инструменты и устанавливайте
гаечные ключи как можно ближе к точке соединения.
Чтобы не допустить повреждения оборудования, НЕ
ПЕРЕТЯГИВАЙТЕ трубные соединения. Не превышайте
максимальный момент затяжки 5-7 Нм.
Не используйте клапан или электромагнитный привод в
качестве рычага.
Изделие не должно подвергаться давлению, скручивающему
усилию или натяжению со стороны трубных соединений.
ЭЛЕКТРОПОДКЛЮЧЕНИЯ
Электроподключение должен выполнять только квалифици-
рованный специалист. Соединение должно отвечать требова-
ниям местных нормативных актов и стандартов.
ОСТОРОЖНО:
Перед выполнением каких-либо работ на изделии выключите
питание, чтобы обесточить компоненты устройства.
Перед вводом в эксплуатацию все зажимные контакты
необходимо надежно затянуть.
В зависимости от напряжения электрические компоненты
следует заземлить в соответствии с местными стандартами
и нормативами.
Чтобы обеспечить надлежащее заземление катушки, при
сборке/разборке ее следует правильно располагать
.
Электрические соединения оборудования следующие:
Съемный соединитель стандарта
ISO 4400 / EN 175301-803,
форма A (при надлежащем заземлении и если используется
соединитель (из комплекта поставки или выбранный) класса
IP65 или IP67, защита электромагнитного клапана будет
соответствовать классу IP65 или IP67).
ВВОД В ЭКСПЛУАТАЦИЮ
Прежде чем создавать давление в контуре, проверьте элек-
тросистему. В случае электромагнитных клапанов несколько
раз включите питание катушки и проверьте наличие метал-
лического щелчка, свидетельствующего о срабатывании со-
леноида.
РАБОТА
Большинство электромагнитных клапанов оснащены катуш-
ками, обеспечивающими длительный срок эксплуатации.
Чтобы избежать травм, не касайтесь электромагнитного
исполнительного устройства, которое может сильно нагре-
ваться даже при нормальных условиях работы. Если электро-
магнитный клапан легкодоступен, специалист по установке
должен обеспечить защиту от случайного контакта.
Наши электромагнитные и управляющие клапаны
предназначены для эксплуатации с устройствами, соот-
ветствующими требованиям стандарта EN 61131-2.
ИЗЛУЧЕНИЕ ЗВУКА
Излучение звука зависит от области применения, рабочей
среды и типа используемого оборудования. Точно опреде-
лить уровень шума может только пользователь после уста-
новки клапана в системе.
ТЕХНИЧЕСКОЕ ОБСЛУЖИВАНИЕ
Обслуживание изделий ASCO зависит от условий эксплуата-
ции. Рекомендуется проводить периодическую очистку, сроки
которой зависят от используемых рабочих сред и условий экс-
плуатации. Во время обслуживания необходимо проверять
компоненты на предмет чрезмерного износа. Полный набор
компонентов доступен в виде запчастей или комплекта для
восстановления изделия. В случае возникновения проблем
при установке или обслуживании, либо при появлении ка-
ких-либо сомнений обратитесь в ASCO или к официальным
представителям компании.
РАЗБОРКА
Разбирайте части в порядке, указанном на иллюстраци-
ях в этой инструкции по установке и техническому обслу-
живанию.
1 - Снимите пружинную защелку (1), нажимая вниз, и катушку
(2) (см. коды катушек на следующих страницах).
2 - Снимите плоскую пружину (10).
3 -
Отвинтите блок внутренней трубки
(3)
и отсоедините его
от корпуса
(4).
4 -
Снимите внутреннюю пружину
(5)(6)
и уплотнение
(8).
5 -
Очистите или замените все детали.
СБОРКА
Соберите детали в порядке, обратном разборке. Убедитесь,
что пружинная защелка правильно установлена на катушке.
(См. чертеж.).
Для пре
дотвращения загрязнения внутренней части элек-
тромагнитного клапана подсоедините выпуск.
ПРИМЕЧАНИЕ:
1 - Смажьте уплотнение (8) и нанесите немного смазки
стандарта AFNOR ISO TR 3498 (категории HL и FC) на
внешнюю окружность сердцевины.
2 - Убедитесь, что блок внутренней трубки надежно затянут
с усилием
(a).
3 - Замените плоскую пружину, катушку и пружинную
защелку. Подсоедините разъем в сборе.
4 -
После сборки несколько раз включите электромагнитный
клапан или коллектор, чтобы убедиться в его работоспо-
собности.
5 -
Соберите трубные соединения и затяните усилием не
более 5-7 Нм.
524685-001 524685-001
18 19
ОРНАТУ ЖƏНЕ ТЕХНИКАЛЫҚ ҚЫЗМЕТ КӨРСЕТУ НҰСҚАУЛЫҚТАРЫ
2
31
2
31
32
KZ
Тікелей басқарылатын, жезден немесе тот баспайтын болаттан
жасалған, 314 1/8 - 1/4 сериялы 3/2 NC-NO соленоид клапандары
СИПАТТАМАСЫ
314, 3/2 сериялы, NC-NO:
Бұрандалы 1/8 дюйм-1/4 дюйм қосылымы бар соленоид кла-
пандары. Мыс немесе тот баспайтын болаттан жасалған корпус.
Катушкалар: Барлық 238 негізгі нөмірлері UL жəне CSA серти-
фикаттарына сəйкес мақұлданған, UR (анықталған құрамдас)
жəне CSA логотиптерімен белгіленген.
ATEX нұсқалары:
"Қауіпсіз пайдалану бойынша арнайы шарттарды" қараңыз.
ҚАУІПСІЗ ПАЙДАЛАНУ ЖӨНІНДЕГІ АРНАЙЫ ШАРТТАР
ATEX директивасына қатысты соленоид операторлары үшін,
өніммен бірг
е берілген арнайы Орнату нұсқауларындағы пай-
далану нұсқаулары қатаң орындалуы қажет.
Бұрандалы байланыстары бар соленоид клапандары:
Стандартты нұсқалар немесе соленоид операторларымен
жабдықталған нұсқалар, Ex d, Ex e mb, Ex mb, Ex tc (SG)Ex
tc (SG) сериялары ATEX-IECE үшін жарылғыш атмосферада
қолдануға арналған.
ЖИНАУ
ASCO құрамдас бөлшектері тек идентификациялық
тақтайшада көрсетілген техникалық сипаттамаға не-
месе құжаттамаға сай қолдануға арналған. Жабдықтың
зақымдалуына жол бермеу үшін, төмен т
емпературада
сұйықтықты қатырып алмаңыз, максималды мен минималды
температура шегінде сақтаңыз.
Жабдықты тек өндіруші немесе оның өкілімен ақылдасқаннан
кейін өзгертуге болады.
Орнатпас бұрын, құбыр жүйесінің қысымын босатып, ішін
тазалаңыз.
Соленоид клапандарын жұмысқа кедергі келтірмей, кез кел-
ген жерде орнатуға болады.
Ағынның бағыты клапан корпусы жəне құжаттамадағы
белгілермен көрсетілген.
Құбыр қосылымдары корпусында, затбелгісінде немесе өнім
кітапшасында көрсетілген өлшемге сай болуы қажет.
ЕСКЕРТУ:
Қосылымдарды қысқарту дұрыс жұмыс дұрыс болмауына
немесе істен шығуға себеп болуы мүмкін.
Жабдықты қорғау үшін, кіріс жағында қамтылған, жарамды то
р
не сүзгіні өнімге барынша жақындатып орнатыңыз.
Егер бекемдеу кезінде таспа, паста, спрей не басқа да сол
сияқты майлағыш пайдаланылса, бөлшектерінің жүйеге кіріп
кетпеуін қадағалаңыз.
Тиісті құралдарды пайдаланып, гайка кілттерін қосылым
нүктесіне барынша жақын орналастырыңыз.
Жабдықтың зақымдалмауы үшін құбыр қосылымдарын
ШАМАДАН ТЫС БЕКІТПЕҢІЗ. Тартудың айналу моменті 5 -
7 Нм дейін болуын тексеріңіз.
Клапанды немесе соленоидты иінтірек ретінде пайдаланбаңыз.
Құбыр қосылымдары өнімге күш түсірмеуі, тартпауы жəне
деформацияға ұшыратпауы керек.
ЭЛЕКТРЛІК ҚОСЫЛЫМ
Барлық электрлік қосылымдар тек жаттықтырылған жəне
білікті қызметкерлер тарапынан жасалуы қажет жəне жергілікті
ережелер мен стандарттарға сай болуы керек.
АБАЙЛАҢЫЗ:
Кез келген жұмысты орындамас бұрын, құрамдастарды өшіру
үшін электр тогын өшіру қажет.
Пайдалануға берілудің алдында барлық электрлік бұрандалы
қысқыштар тиісті түрде бекітілуі тиіс.
Кернеуге байланысты электрлік құрамдастар жергілікті стан-
дарттар мен ережелерге сəйкес жерге тұйықталуы қажет.
Катушканың жерге үздіксіз тұйықталуын қамтамасыз ету үшін,
жина
у/бөлшектеу кезінде дұрыс орналасқанына көз жеткізіңіз
( 1).
Жабдықтың төменде көрсетілгендей электр байланысы бар:
ISO 4400 / EN 175301-803 стандартына сəйкес алмалы-салмалы
жалғағыш, А формасы (тиісті байланыста жəне қолданылған
жалғағыш ( жабдықталған немесе таңдап алынған) IP65- немесе
IP67-номиналды болғанда, соленоид клапанында IP65 немесе
IP67 қорғанысы болады)
.
ПАЙДАЛАНУҒА БЕРУ
Тізбекті қысымдаудан бұрын электрлік сынақ жүргізіңіз. Со-
леноид клапандары бар болған жағдайда катушканы қуат
көзіне бірнеше рет қосыңыз жəне соленоид клапан жұмысын
білдіретін металл ілмекке назар аударыңыз.
ФУНКЦИЯСЫ
Көптеген соленоид клапандары ұзақ қызмет ету үшін катуш-
калармен жабдықталған. Жеке жарақат алу мүмкіндігіне жол
бермеу үшін, қалыпты жұмыс шарттарында қызуы мүмкін
с
оленоидке тиіспеңіз. Соленоидты клапанға қол жеткізу оңай
болса, орнатушы кездейсоқ тиіп кетуге қарсы қорғаныспен
қамтамасыз етуі қажет.
Соленоид клапандары мен басқарушы клапандар EN 61131-2
стандартына сай келетін құрылғылармен жұмыс істеуге
арналған.
ДЫБЫС ШЫҒАРУ
Дыбыстың шығуы қолданбаға, сұйықтыққа жəне пайдаланы-
латын жабдықтар түріне байланысты. Дыбыс деңгейі клапан
жүйеге пайдаланушы тарапынан орнатылған жағдайда ғана
нақты анықталады.
ТЕХНИКАЛЫҚ ҚЫЗМЕТ КӨРСЕТУ
ASCO өнімдеріне техникалық қызмет көрсету процедура-
сы қызмет көрсету шарттарына байланысты. Жиі тазалап
тұрған дұрыс, тазалау мерзімі қолданылатын сұйықтықтар
мен қызмет көрсету шарттарына тəуелді. Қызмет көрсету
барысында құрамдастардың шамадан тыс тозуы тексерілуі
тиіс. Ішкі бөлшектердің толық жиынтығы қосалқы бөлшектер
немесе жөндеу жинағы ретінде қолжетімді. Егер орнату/
техникалық қызмет көрсету кезінде ақаулық туындаса неме-
се күмəндансаңыз, ASCO компаниясына немесе оның заңды
өкілдеріне хабарласыңыз.
БӨЛШЕКТЕУ
Бөлшектерді осы Орнату жəне техникалық қызмет көрсету
нұсқаулығындағы суреттерде көрсетілген ретпен бөлшектеңіз.
1 - қысымды төмендетіп, бекітуші қысқышты (1) жəне катуш-
каны (2) алып тастаңыз ( келесі беттерден катушкалар кодтар
қараңыз).
2 - Жалпақ серіппені (10) алыңыз.
2 - Өзек түтігі элементін (3) бұрап шығарыңыз жəне оны кор-
пустан (4) ажыратыңыз.
3 - Өзек/серіппе элементін (5)(6) жəне тығыздамасын (8) алып
тастаңыз.
4 - Барлық бөліктерді тазалаңыз немесе ауыстырыңыз.
ҚАЙТА ЖИНАУ
Бөліктерді бөлшектеудің кері ретімен қайта жинаңыз.
Бекітуші қысқыштың өзекте дұрыс орналасқанына көз жеткізіңіз
(суретті қараңыз).
Соленоид клапанының іші ластанбауы үшін шығыс тетік
жалғануы керек.
ЕСКЕРТПЕ:
1 - Тығыздаманы (8) жағыңыз жəне өзектің сыртқы айналасын HL
мен FC санаттарындағы AFNOR ISO TR 3498 стандартына
сай маймен сəл майлап қойыңыз.
2 - Өзек түтігі элементі бұрау моментінде ( а) дұрыс бекітілгеніне
көз жеткізіңіз.
3 - Жалпақ серіппе, катушка жəне бекітуші қысқышты
ауыстырыңыз. Коннектор жинағын жалғаңыз.
4 - Қайта жинағаннан кейін, клапанның тиісті түрде ашылып
жабылуын қамтамасыз ету үшін соленоид клапанын бірнеше
рет жұмыс істетіңіз.
5 - Құбыр қосылымдарын қайта жинаңыз жəне 5 - 7 Нм макси-
малды бұрау моментінде бекітіңіз.
&
AC (~)
/
DC (=)
/
NBR FPM
FPM (oxygen)
EPDM NBR FPM
FPM (oxygen)
EPDM
G314K031 M200070N00 M200070V00 M200070VN0 M200070E00 M200066N00 M200066V00 M200066VN0 M200066E00
G314K032/033 M200071N00 M200071V00 M200071VN0 M200071E00 M200067N00 M200067V00 M200067VN0 M200067E00
G314K037 M200072N00 M200072V00 M200072VN0 M200072E00 M200068N00 M200068V00 M200068VN0 M200068E00
G314K038/039 M200073N00 M200073V00 M200073VN0 M200073E00 M200069N00 M200069V00 M200069VN0 M200069E00
G314K040 M200079N00 M200079V00 M200079VN0 M200079E00 M200077N00 M200077V00 M200077VN0 M200077E00
G314K041 M200074N00 M200074V00 M200074VN0 M200074E00 M200074N00 M200074V00 M200074VN0 M200074E00
G314K042 M200076N00 M200076V00 M200076VN0 M200076E00 M200076N00 M200076V00 M200076VN0 M200076E00
G314K043 M200078N00 M200078V00 M200078VN0 M200078E00 M200075N00 M200075V00 M200075VN0 M200075E00
G314K044 M200079N00 M200079V00 M200079VN0 M200079E00 M200077N00 M200077V00 M200077VN0 M200077E00
G314K045 M200078N00 M200078V00 M200078VN0 M200078E00 M200075N00 M200075V00 M200075VN0 M200075E00
G314K049 M200080N00 M200080V00 M200080VN0 M200080E00 M200080N00 M200080V00 M200080VN0 M200080E00
G314K050/051 M200081N00 M200081V00 M200081VN0 M200081E00 M200081N00 M200081V00 M200081VN0 M200081E00
G314K055 M200080N00 M200080V00 M200080VN0 M200080E00 M200080N00 M200080V00 M200080VN0 M200080E00
G314K056/057 M200083N00 M200083V00 M200083VN0 M200083E00 M200083N00 M200083V00 M200083VN0 M200083E00
3/2 NC-NF
3/2 N0-NA
314 (1/8)
F
items N.m
Inch.pounds
a
20
±3
175
±25
2
1
2
1
2
1
3/2 U
1
2
3
3b
6
5
8
10
4
1
2
3
1
2
3
a
U
L
SPARE PARTS KIT
GB
POCHETTES DE RECHANGE
FR
ERSATZTEILPACKUNG
DE
BOLSAS DE RECAMBIO
ES
PARTI DI RICAMBIO
IT
VERVANGINGSSET
NL
RESERVDELSSATS
SE
RESERVEDELSPAKKE
NO
VARAOSASARJA
FI
RESERVEDELE KIT
DK
KIT DE PEÇAS DE SOBRESSELENTES
PT
ÊÉÔ ÁÍÔÁËËÁÊÔÉÊÙÍ
GR
SADA NÁHRADNÍCH DÍLU
CZ
ZESTAW CZĘŚCI ZAMIENNYCH
PL
PÓTALKATRÉSZ KÉSZLET
HU
КОМПЛЕКТ ЗАПЧАСТЕЙ
RU
ҚОСАЛҚЫ БӨЛШЕКТЕР ЖИНАҒЫ
KZ
-
-
524685-001 524685-001
20 21
&
AC (~)
/
DC (=)
/
NBR FPM
FPM (oxygen)
EPDM NBR FPM
FPM (oxygen)
EPDM
E314K034 M200070N00 M200070V00 M200070VN0 M200070E00 M200066N00 M200066V00 M200066VN0 M200066E00
E314K035/036 M200071N00 M200071V00 M200071VN0 M200071E00 M200067N00 M200067V00 M200067VN0 M200067E00
E314K006 M200074N00 M200074V00 M200074VN0 M200074E00 M200074N00 M200074V00 M200074VN0 M200074E00
E314K007/008 M200078N00 M200078V00 M200078VN0 M200078E00 M200075N00 M200075V00 M200075VN0 M200075E00
E314K052 M200080N00 M200080V00 M200080VN0 M200080E00 M200080N00 M200080V00 M200080VN0 M200080E00
E314K053/054 M200081N00 M200081V00 M200081VN0 M200076E00 M200081N00 M200081V00 M200081VN0 M200081E00
E314K068 M200072N00 M200072V00 M200072VN0 M200072E00 M200068N00 M200068V00 M200068VN0 M200068E00
E314K121/126 M200073N00 M200073V00 M200073VN0 M200073E00 M200069N00 M200069V00 M200069VN0 M200069E00
E314K123 M200076N00 M200076V00 M200076VN0 M200076E00 M200076N00 M200076V00 M200076VN0 M200076E00
E314K120/124 M200079N00 M200079V00 M200079VN0 M200079E00 M200077N00 M200077V00 M200077VN0 M200077E00
E314K069 M200082N00 M200082V00 M200082VN0 M200082E00 M200082N00 M200082V00 M200082VN0 M200082E00
E314K122/070 M200083N00 M200083V00 M200083VN0 M200083E00 M200083N00 M200083V00 M200083VN0 M200083E00
3/2 NC-NF
3/2 N0-NA
314 (1/4)
F
items N.m
Inch.pounds
a
20
±3
175
±25
2
1
2
1
1
2
3
3
6
5
8
10
4
1
2
3
3
2
1
1
2
3
3
3/2 U
a
U
L
SPARE PARTS KIT
GB
POCHETTES DE RECHANGE
FR
ERSATZTEILPACKUNG
DE
BOLSAS DE RECAMBIO
ES
PARTI DI RICAMBIO
IT
VERVANGINGSSET
NL
RESERVDELSSATS
SE
RESERVEDELSPAKKE
NO
VARAOSASARJA
FI
RESERVEDELE KIT
DK
KIT DE PEÇAS DE SOBRESSELENTES
PT
ÊÉÔ ÁÍÔÁËËÁÊÔÉÊÙÍ
GR
SADA NÁHRADNÍCH DÍLU
CZ
ZESTAW CZĘŚCI ZAMIENNYCH
PL
PÓTALKATRÉSZ KÉSZLET
HU
КОМПЛЕКТ ЗАПЧАСТЕЙ
RU
ҚОСАЛҚЫ БӨЛШЕКТЕР ЖИНАҒЫ
KZ
-
-
24 V = 48 V = 24 V ~ 48 V ~ 115 V ~ 230 V ~
MXX II -FT
11,6 W
238513-006 238513-017 - - - -
10,1 W - - 238213-006 238213-016 238213-033 238213-059
=
=
22
=
=
22
Ø M5 - 7,5 mm
1/4
314 (1/4)
AISI 1010
(1.1121)
M200094A00
Í
Í
64
52
36
43
36
5
20
6
45
22,4
21,8
17,3
15
6,4 x 2
35,45
37,7
6,4 x 4
22,4
15
21,8
17,3
9
1,5
6
24
R6 x 2
7,1
9,35
20,8
24,5
6.8
10,5
18
3,2 x 4
6
x 4
F
F
AISI 304
(1.4301)
M200095A00
Ø M5 - 6,5 mm
=
=
17,5
=
=
15
1/8
&
&
U
L
SPARE PARTS KIT
GB
POCHETTES DE RECHANGE
FR
ERSATZTEILPACKUNG
DE
BOLSAS DE RECAMBIO
ES
PARTI DI RICAMBIO
IT
VERVANGINGSSET
NL
RESERVDELSSATS
SE
RESERVEDELSPAKKE
NO
VARAOSASARJA
FI
RESERVEDELE KIT
DK
KIT DE PEÇAS DE SOBRESSELENTES
PT
ÊÉÔ ÁÍÔÁËËÁÊÔÉÊÙÍ
GR
SADA NÁHRADNÍCH DÍLU
CZ
ZESTAW CZĘŚCI ZAMIENNYCH
PL
PÓTALKATRÉSZ KÉSZLET
HU
КОМПЛЕКТ ЗАПЧАСТЕЙ
RU
ҚОСАЛҚЫ БӨЛШЕКТЕР ЖИНАҒЫ
KZ
-
-
524685-001 524685-001
22 23
GB Description FR Description DE Bezeichnung
1. Retaining clip
2. Coil
3a.
(M6)
3b.
(MXX)
4. Body
5. Core
6. Spring
8. O-ring
10 . Flat spring
1. Clip de maintien
2.
Bobine
3a.
(M6)
3b.
(MXX)
4. Corps
5. Noyau
6. Ressort
8. Joint torique
10 . Ressort plat
1. Halteclip
2. Magnet
3. Ersatzteil
3a.
(M6)
3b.
(MXX)
4. Gehäuse
5. Magnetanker
6. Feder
8. O-Ring
10 . Flachfeder
ES Descripcion IT Descripzione NL Beschrijving
1. Clip de manteni-
miento
2. Bobina
3a.
(M6)
3b.
(MXX)
4. Cuerpo
5. Núcleo
6.
Resorte
8. Junta tórica
10 . Resorte plano
1. Clip di fi ssaggio
2.
Bobina
3. Parte di ricambio
3a.
(M6)
3b.
(MXX)
4. Corpo
5. Nucleo
6.
Molla
8. O-ring
10 . Molla piatta
1. Borgclip
2.
Spoel
3a.
(M6)
3b.
(MXX)
4. Huis
5. Plunjer
6.
Veer
8. O-ring
10. Vlakke veer
NO Beskr
ivelse SE Beskrivning FI Kuvaus
1. Festeklemme
2. Spolen
3a. (M6)
3b. (MXX)
4. Kropp
5. Kjerne
6.
Fjære
8. O-ring
10. Flat fjær
1. Fästklämma
2.
Spole
3a. (M6)
3b. (MXX)
4. Stomme
5. Kärna
6.
Fjäder
8. O-ring
10. Platt fjäder
1. Kiinnityssinkilä
2.
Käämi
3a. (M6)
3b. (MXX)
4. Runko
5. Ydin
6.
Jousi
8. O-rengas
10. Lattajousi
DK Beskr
ivelse PT Descrição GR
Περιγραφή
1. Fastholdelses-
klips
2. Spole
3a. (M6)
3b. (MXX)
4. Hus
5. Kerne
6.
Fjeder
8. O-ring
10. Flad fjeder
1. Br
açadeira de
xação
2. Bobina
3a.
(M6)
3b.
(MXX)
)
4. Corpo
5. Núcleo
6.
Mola
8. Junta Tórica
10 . Mola plana
1. Συνδετήρας συγκρά-
τησης
2. Πηνίο
3a.
(M6)
3b.
(MXX)
4. Body
5. Πυρήνας
6. Ελατήριο
8. Δακτύλ
ιος Ο
10 . Flat spring
CZ P
opis PL Opis HU Leírás
1. Příchytka
2. Vinutí
3a. (M6)
3b. (MXX)
4. Tělo
5. Jádro
6. Pružina
8. O-kroužek
10. Pružná
podložka
1. Zacisk mocujący
2. Cewka
3a. (M6)
3b. (MXX)
4. Korpus
5. Rdzeń
6. Sprężyna
8. O-ring
10. Płaska
sprężyna
1. Tartókapocs
2. T
ekercs
3a. (M6)
3b. (MXX)
4. Test
5. Mag
6. Rugó
8. Tömítőgyűrű
10. Lapos rugó
RU
Опис
ание
KZ
Сипаттамасы
1. Пружинная
защелка
2. Катушка
3a. (M6)
3b. (MXX)
4. Корпу
с
5. Сердечник
6. Пружина
7. Plug
8. Уплотнитель-
ное кольцо
10. Плоская
пружина
1. Бекіт
уші қысқыш
2. Катушка
3a.
(M6)
3b.
(MXX)
4. Корпус
5. Өзек
6. Серіппе
8. О тəрізді сақина
10. Жалпақ
серіппе
ASCO SAS
53 rue de la Beauce, 28110 Luce - FRANCE
775 729 098 RCS Chartres
SPARE PARTS KIT
GB
POCHETTES DE RECHANGE
FR
ERSATZTEILPACKUNG
DE
BOLSAS DE RECAMBIO
ES
PARTI DI RICAMBIO
IT
VERVANGINGSSET
NL
RESERVDELSSATS
SE
RESERVEDELSPAKKE
NO
VARAOSASARJA
FI
RESERVEDELE KIT
DK
KIT DE PEÇAS DE SOBRESSELENTES
PT
ÊÉÔ ÁÍÔÁËËÁÊÔÉÊÙÍ
GR
SADA NÁHRADNÍCH DÍLU
CZ
ZESTAW CZĘŚCI ZAMIENNYCH
PL
PÓTALKATRÉSZ KÉSZLET
HU
КОМПЛЕКТ ЗАПЧАСТЕЙ
RU
ҚОСАЛҚЫ БӨЛШЕКТЕР ЖИНАҒЫ
KZ
-
-

Transcripción de documentos

Installation and Maintenance Instructions 3/2 solenoid valves NC-NO-U, direct operated, brass or stainless steel body, series 314 1/8 - 1/4 2 2 3 1 3 1 3 2 Instructions de mise en service et d'entretien GB Electrovannes 3/2 NF-NO-U, à commande directe corps laiton ou acier inox, séries 314 1/8 - 1/4 DESCRIPTION Série 314, 3/2 NF-NO : • Electrovannes, taraudé 1/8-1/4. Corps laiton ou acier inox. Bobines : Tous les codes de base 238 sont agréés UL & CSA avec les logos UL & CSA qui conviennent. Versions ATEX : Voir "conditions spéciales pour une utilisation sûre". PUTTING INTO OPERATION Before pressurising the circuit, perform an electrical test. In case of solenoid valves, energise the coil a few times and notice a metal click signifying the solenoid operation. DESCRIPTION Series 314, 3/2 NC-NO-U: • Solenoid valves with threaded 1/8-1/4 connections. Brass or stainless steel body. Coils: All 238 basic numbers are UL & CSA approved and marked with the UR (recognised component) & CSA logos. ATEX versions: See “Special conditions for safe use”. FUNCTION Most solenoid valves are equipped with coils for continuous duty service. To prevent the risk of personal injury, do not touch the solenoid operator which can become hot under normal operating conditions. If the solenoid valve is easily accessible, the installer must provide protection against accidental contact. Our solenoid valves and pilot valves are designed to operate with devices compliant with EN 61131-2 standard. SPECIAL CONDITIONS FOR SAFE USE For solenoid operators to ATEX, the instructions for use given in the specific Installation Instructions provided with the product must be strictly followed. Solenoid valves with threaded connections: Standard versions or versions equipped with solenoid operators, Ex d, Ex e mb, Ex mb, Ex tc (SG), for use in explosive atmospheres to ATEX-IECEx. SOUND EMISSION The emission of sound depends on the application, fluid and type of equipment used. The exact determination of the sound level can only be carried out by the user having the valve installed in his system. ASSEMBLY The components ASCO are intended to be used only within the technical characteristics specified on the nameplate or in the documentation. To avoid damage to the equipment, make sure to prevent the liquid from solidifying at low temperatures and stay within the maximum and minimum temperature limits. Modifications to the equipment may only be made after consulting the manufacturer or his representative. Before installation, depressurise the piping system and clean internally. The solenoid valves may be mounted in any position without affecting operation. The direction of flow is indicated by markings on the valve’s body and in the documentation. Pipe connections have to be in accordance with the size indicated on the body, label or in the product leaflet. CAUTION : • Reducing the connections may cause improper operation or malfunction. • For the protection of the equipment, install a strainer or filter suitable for the service involved in the inlet side as close to the product as possible. • If tape, paste, spray or a similar lubricant is used when tightening, avoid particles entering the system. • Use proper tools and locate wrenches as close as possible to the connection point. • To avoid damage to the equipment, DO NOT OVERTIGHTEN pipe connections. Observe a maximum tightening torque of 5 to 7 Nm. • Do not use the valve or solenoid operator as a lever. • Pipe connections should not apply any force, torque or strain to the product. MAINTENANCE Maintenance of ASCO products is dependent on service conditions. Periodic cleaning is recommended, the timing of which will depend on the fluids used and the service conditions. During servicing, the components must be checked for excessive wear. A complete set of internal parts is available as a spare parts or rebuild kit. If a problem occurs during installation/maintenance or in case of doubt, please contact ASCO or authorised representatives. REASSEMBLY Reassemble the parts in the reverse order of disasseambly. Make sure the retaining clip is correctly positioned on the coil (see drawing). The exhaust must be connected to prevent contamination of the inside of the solenoid valve. NOTE: 1 - Grease the seal (8) and lightly coat the outer circumference of the core with a lubricant conforming to standard AFNOR ISO TR 3498 categories HL and FC. 2 - Make sure the core-tube unit is properly tightened at a torque (a). 3 - Replace flat spring, coil and retaining clip. Connect the connector assembly. 4 - After reassembly, operate the solenoid valve several times to ensure the valves open and close properly. 5 - Reassemble the piping connections and tighten at a maximum torque of 5 to 7 Nm. 524685-001 / A ELECTRICAL CONNECTION All electrical connections must only be made by trained and qualified personnel and have to be in accordance with the local regulations and standards. CAUTION: • Before any intervention, turn off the electrical current to power off the components. • All screw terminals must be properly tightened before putting into service. • Depending on the voltage, electrical components must be grounded according to local standards and regulations. • To ensure ground continuity of the coil, make sure it is correctly positioned during assembly/disassembly (no. 1). The equipment is electrically connected as follows: • Detachable connector to ISO 4400 / EN 175301-803, form A (On proper connection and when the (supplied or selected) connector used is IP65- or IP67-rated, the solenoid valve will have IP65 or IP67 protection). 2 524685-001 Availability, design and specifications are subject to change without notice. All rights reserved. DISASSEMBLY Disassemble the parts in the order indicated in the views in these I&M Instructions 1 - Remove the retaining clip (1), maintain pressure downwards, and the coil (2) (see coil codes on following pages). 2 - Remove the flat spring (10). 2 - Unscrew the core-tube unit (3) and separate it from the body (4). 3 - Remove the core/spring unit (5)(6) and the seal (8). 4 - Clean or replace all parts. 2 2 3 1 3 1 3 2 FR MISE EN SERVICE Avant de mettre le circuit sous pression, effectuer un essai électrique. Dans le cas d’une électrovanne, mettre la bobine sous tension plusieurs fois et écouter le “clic” métallique qui signale le fonctionnement de la tête magnétique. FONCTIONNEMENT La plupart des électrovannes comportent des bobinages prévus pour mise sous tension permanente. Pour éviter toute brûlure, ne pas toucher la tête magnétique qui, en fonctionnement normal et en permanence sous tension, peut atteindre une température élevée. Si l’électrovanne est facilement accessible, l’installateur doit prévoir une protection empêchant tout contact accidentel. Nos électrovannes et électrovannes-pilotes sont prévues pour fonctionner avec des dispositifs conformes norme EN 61131-2 CONDITIONS SPECIALES POUR UNE UTILISATION SURE Pour les têtes magnétiques ATEX, suivre impérativement les prescriptions d'utilisation décrites dans chaque notice de mise en service spécifique fournie avec le produit. Electrovannes, corps taraudé : Versions standard ou équipées de têtes magnétiques pour atmosphères explosibles ATEX-IECEx, Ex d, Ex e mb, Ex mb, Ex tc (SG). MONTAGE Les composants ASCO sont conçus pour les domaines de fonctionnement indiqués sur la plaque signalétique ou la documentation. Afin de prévenir tout dommage sur le matériel, éviter le risque de solidification des liquides aux basses températures et respecter les limites minimale et maximale. Aucune modification ne peut être réalisée sur le matériel sans l’accord préalable du fabricant ou de son représentant. Avant de procéder au montage, dépressuriser les canalisations et effectuer un nettoyage interne. Les électrovannes peuvent être montées dans n’importe quelle position. Le sens de circulation du fluide est indiqué par repères sur le corps et dans la documentation. La dimension des tuyauteries doit correspondre au raccordement indiqué sur le corps, l’étiquette ou la notice. ATTENTION : • Une restriction des tuyauteries peut entraîner des dysfonctionnements. • Afin de protéger le matériel, installer une crépine ou un filtre adéquat en amont, aussi près que possible du produit. • En cas d’utilisation de ruban, pâte, aérosol ou un lubrifiant lors du serrage, veiller à ce qu’aucun corps étranger ne pénètre dans le circuit. • Utiliser un outillage approprié et placer les clés aussi près que possible du point de raccordement. • Afin d’éviter toute détérioration, NE PAS TROP SERRER les raccords des tuyauteries. Couple de serrage maximum entre 5 et 7 Nm. • Ne pas se servir de la vanne ou de la tête magnétique comme d’un levier. • Les tubes de raccordement ne devront exercer aucun effort, couple ou contrainte sur le produit. DEMONTAGE Démonter les pièces en suivant l’ordre indiqué sur les vues de cette notice. 1 - Oter le clip de maintien (1), en maintenant une pression vers le bas, et enlever la bobine (2) (voir codes bobines, pages suivantes). 2 - Retirer le ressort plat (10) 3 - Dévisser l'ensemble tube-culasse (3) et le séparer du corps (4). 4 - Enlever l’ensemble noyau ressort (5)(6) et le joint d’étanchéité (8). 5 - Nettoyer ou remplacer toutes les pièces. RACCORDEMENT ÉLECTRIQUE Le raccordement électrique doit être réalisé par un personnel qualifié et selon les normes et règlements locaux. ATTENTION: • Avant toute intervention, couper l’alimentation électrique pour mettre hors tension les composants. • Toutes les bornes à vis doivent être serrées correctement avant la mise en service. • Selon la tension, les composants électriques doivent être mis à la terre conformément aux normes et règlements locaux. • Afin d'assurer la continuité de masse de la bobine, veuillez à son positionnement correct lors d'une phase de montage/ démontage (rep. 1). Le raccordement électrique s’effectue par: • Connecteur débrochable ISO 4400 / EN 175301-803, forme A (Quand le raccordement est correctement effectué et que le modèle de connecteur fourni ou sélectionné est IP65 ou IP67, alors le degré de protection de l'électrovanne est IP65 ou IP67). REMONTAGE Remonter les pièces dans l’ordre inverse du démontage. S’assurer que le clip de maintien est correctement positionné, sur la bobine (voir dessin). La purge doit être raccordée pour éviter toute pollution interne de l'électrovanne. NOTE : 1 - Lubrifier le joint d’étanchéité (8) et lubrifier légèrement le diamètre extérieur du noyau avec une huile conforme aux normes AFNOR ISO TR 3498 catégorie HL et FC. 2 - S'assurer du serrage correct de l'ensemble tube-culasse, couple de serrage (a) 3 - Replacer le ressort plat, la bobine et le clip de maintien. Raccorder le connecteur. 4 - Après remontage, faire fonctionner l'électrovanne plusieurs fois afin de s’assurer qu’ils s’ouvrent et se ferment correctement. 5 - Remonter les raccords de tuyauterie, couple de serrage maximum entre 5 et 7 Nm. BRUIT DE FONCTIONNEMENT Le bruit de fonctionnement varie selon l’utilisation, le fluide et le type de matériel employé. L’utilisateur ne pourra déterminer avec précision le niveau sonore émis qu’après avoir monté le composant sur l’installation. ENTRETIEN L’entretien nécessaire aux produits ASCO varie avec leurs conditions d’utilisation. Il est souhaitable de procéder à un nettoyage périodique dont l’intervalle varie suivant la nature du fluide, les conditions de fonctionnement et le milieu ambiant. Lors de l’intervention, les composants doivent être examinés pour détecter toute usure excessive. Un ensemble de pièces internes est proposé en pièces de rechange pour procéder à la réfection. En cas de problème lors du montage/ entretien ou en cas de doute, veuillez contacter ASCO ou ses représentants officiels. 3 524685-001 Inbetriebnahme- und Wartungsanleitung Magnetventile 3/2 NC-NO-U, direkt betätigt Gehäuse aus Messing oder Edelstahl, 1/8 - 1/4, Baureihe 314 BESCHREIBUNG Baureihe 314, 3/2 NC-NO-U: • Magnetventile mit 1/8-1/4 -Gewindeanschlüssen, Messing oder Edelstahl. Magnetspule: Alle 238 Basisnummern sind UL- und CSAzugelassen und mit den entsprechenden UL- und CSA-Logos gekennzeichnet. Ausführungen nach ATEX: Siehe „Besondere Bedingungen für den sicheren Einsatz“: 2 2 3 1 3 1 3 2 DE und bei Verwendung einer Leitungsdose (mitgeliefert oder kundenseitig) der Schutzart IP65 oder IP67, hat das Magnetventil die Schutzart IP65 bzw. IP67). INBETRIEBNAHME Vor Druckbeaufschlagung des Produktes sollte eine elektrische Funktionsprüfung erfolgen. Bei einem Magnetventil ist die Spannung am Magnet mehrmals ein- und ausschalten. Es muss ein Klicken zu hören sein. FUNKTIONSBESCHREIBUNB Die meisten Ventile sind mit Spulen für Dauerbetrieb ausgerüstet. Zur Vermeidung von Personen- und Sachschäden sollte jede Berührung mit dem Magnet vermieden werden, da dieser bei längerem Betrieb heiß werden kann. Bei leicht zugänglichem Magnetventil sollte vom Installateur ein Schutz vorgesehen werden, um jegliches versehentliches Berühren zu vermeiden. Unsere Magnetventile und Pilotventile sind für den Betrieb mit Betriebsmitteln nach der Norm EN 61131-2 ausgelegt. GERÄUSCHEMISSION Der Anwender kann erst präzise Angaben zur Geräuschemission machen, wenn das Gerät in der Anlage installiert ist. Diese hängt sehr stark vom Anwendungsfall, den Betriebsdaten und dem Medium, mit denen das Produkt beaufschlagt wird, ab. BESONDERE BEDINGUNGEN FÜR DEN SICHEREN EINSATZ Für die Magnetköpfe nach ATEX sind die in den jeweiligen, dem Produkt beigelegten Einbau- und Wartungsanweisungen beschriebenen Einsatzvorschriften zwingend zu befolgen. Magnetventile -Gewindeanschlüssen: Standard-Version oder Version mit Magnetköpfen - Ex d, Ex e mb, Ex mb, Ex tc (SG) - für den Einsatz in explosionsfähigen Atmosphären nach ATEX-IECEx. EINBAU ASCO-Komponenten dürfen nur innerhalb der auf dem Typenschild oder in der Dokumentation angegebenen Daten eingesetzt werden. Um Schäden am Ventil zu vermeiden ist darauf zu achten, dass ein Gefrieren des Medium bei Minustemperaturen vermieden wird und die minimal und maximal angegebenen Temperaturen eingehalten werden. Änderungen an den Produkten dürfen nur nach vorheriger Zustimmung des Herstellers oder einem seiner ordnungsgemäß ermächtigten Vertreter vorgenommen werden. Vor dem Einbau der Ventile muss das Rohrleitungssystem drucklos geschaltet und innen gereinigt werden. Die Magnetventile können ohne Beeinträchtigung der Funktion in jeder beliebigen Einbaulage montiert werden. Die Durchflussrichtung des Mediums ist am Gehäuse und in der Dokumentation angezeigt Die Verrohrung sollte entsprechend den Größenangaben auf dem Gehäuse, dem Etikett oder den Produkt-Datenblättern durchgeführt werden. ACHTUNG: • Eine Reduzierung der Anschlüsse kann zu Leistungs- und Funktionsminderungen führen. • Zum Schutz der Ventile ist ein geeigneter Schmutzfänger oder Filter so nahe wie möglich am Ventileingang anzubringen. • Bei der Abdichtung des Gewindes mit Band, Paste, Spray oder einem anderen Dichtungsmittel ist darauf zu achten, dass keine Fremdkörper in das System gelangen. • Zur Montage ist nur geeignetes Werkzeug zu verwenden; die Schraubenschlüssel sind so nahe wie möglich an den Verbindungsstellen anzusetzen. • Um Schäden zu vermeiden, dürfen die Rohrverbindungen NICHT ZU STARK angezogen werden. Der maximale Anziehdrehmoment beträgt 5 bis 7 Nm. • Das Ventil oder der Magnetkopf sind nicht als Gegenhalter zu benutzen. • Die Rohrleitungsanschlüsse dürfen keine Spannungen auf das Ventil übertragen. WARTUNG Die Wartung hängt von den Betriebsbedingungen ab. Das Ventil ist in regelmäßigen Zeitabständen zu reinigen. Die Zeitabstände hängen von den Betriebsbedingungen und dem verwendeten Medium ab. Während des Reinigungsvorgangs sollten alle Teile auf Verschleiß untersucht werden. Die Innenteile sind komplett als Ersatzteilsatz erhältlich. Treten Schwierigkeiten beim Einbau oder bei der Wartung auf oder ergeben sich Unklarheiten, ist mit ASCO Rücksprache zu halten. AUSBAU Bauen Sie die Teile in der Reihenfolge ab wie in den Zeichnungen in dieser Anleitung angegeben. 1 - Entfernen Sie den Halteclip (1), dabei den Druck nach unten beibehalten, und den Magnet (2) (siehe BestellCodes der Magnete auf der Folgende Seiten). 2 - Entfernen Sie die Flachfeder (10) 3 - Lösen Sie die Führungsrohr-Einheit (3) und nehmen Sie diese aus dem Gehäuse (4). 4 - Entfernen Sie die Magnetanker/Feder-Einheit (5)(6) und die Dichtung (8). 5 - Reinigen oder ersetzen Sie alle Teile. WIEDEREINBAU Setzen Sie die Teile in der umgekehrten Reihenfolge wie beim Ausbau zusammen. Stellen Sie sicher, dass der Halteclip richtig auf dem Magnet platziert ist (siehe Zeichnung). Der Entlüftungsanschluss ist mit einem Schalldämpfer zu versehen, um eine Verschmutzung der Innenteile des Ventils zu vermeiden. ANMERKUNG: 1 - Fetten Sie die Dichtung (8) ein und schmieren Sie den Außendurchmesser des Magnetankers mit einer leichten Schicht Fett ein, das der Norm AFNOR ISO TR 3498, Kategorien HL und FC, entspricht. 2 - Vergewissern Sie sich, dass die Führungsrohr-Einheit richtig mit einem Drehmoment (A) festgezogen ist. 3 - Flachfeder, Spule und Halteklammer wieder anbringen. Gerätesteckdose anschließen. 4 - Nach dem Wiedereinbau bzw. der Ventilblock mehrmals ein- und auszuschalten um sicherzustellen, dass die Ventile richtig öffnen und schließen. 5 - Montieren Sie die Rohrleitungsanschlüsse und ziehen Sie sie mit einem maximalen Drehmoment von 5 bis 7 Nm fest. ELEKTRISCHER ANSCHLUSS Der elektrische Anschluss ist von Fachpersonal entsprechend den vor Ort geltenden Normen und Richtlinien durchzuführen. ACHTUNG: • Vor Beginn jeglicher Arbeiten ist sicherzustellen, dass die Komponenten spannungslos geschaltet sind. • Alle Anschlussklemmen sind vor Inbetriebnahme vorschriftsmäßig anzuziehen. • Je nach Spannungsbereich müssen elektrische Komponenten einen Schutzleiteranschluss entsprechend den jeweils vor Ort geltenden Normen und Vorschriften erhalten. • Um den Masseanschluss des Magnets zu gewährleisten ist auf die korrekte Lage des Magnets bei den Einbau- und Ausbaumaßnahmen zu achten (Nr. 1). Der elektrische Anschluss erfolgt folgendermaßen: • Abnehmbare Leitungsdose nach ISO 4400 / EN 175301-803, bauform A (Bei ordnungsgemäß durchgeführtem Anschluss 4 524685-001 Instrucciones de puesta en marcha y mantenimiento Electroválvulas 3/2 NC-NA-U, de mando directo cuerpo de latón o acero inox, 1/8 - 1/4, series 314 2 2 3 1 3 1 3 2 ES PUESTA EN MARCHA Se debe efectuar una prueba eléctrica antes de someter a presión el sistema. En el caso de las válvulas solenoides, se debe energizar varias veces la bobina y comprobar que se produce un sonido metálico que indica el funcionamiento del solenoide. DESCRIPCIÓN Serie 314, 3/2 NC-NA: • Electroválvulas, roscada 1/8-1/4. Cuerpo de latón o acero inox. Bobinas: los 238 números básicos están homologados por UL y CSA y están marcados con los logotipos correspondientes de UL y CSA. Versiones ATEX: Ver "condiciones especiales para una utilización segura". FUNCIONAMIENTO La mayor parte de las válvulas solenoides se suministran con bobinas para un servicio continuo. Con el fin de evitar la posibilidad de daños personales o materiales no se debe tocar el solenoide, ya que puede haberse calentado en condiciones normales de trabajo. Si la electroválvula es de fácil acceso, el instalador debe prever una protección que impida cualquier contacto accidental. Nuestras electroválvulas y electroválvulas-piloto están previstas para funcionar con dispositivos conforme a la norma EN 61131-2. CONDICIONES ESPECIALES PARA UNA UTILIZACIÓN SEGURA Para las cabezas magnéticas ATEX, siga imperativamente las prescripciones de utilización descritas en cada hoja de puesta en marcha específica provista con el producto. Electroválvulas, cuerpo roscado : Versiones standard o equipadas de cabezas magnéticas para atmósferas explosivas ATEX-IECEx, Ex d, Ex e mb, Ex mb, Ex tc (SG). MONTAJE Los componentes ASCO están diseñados para los campos de funcionamiento indicados en la placa de características o la documentación. Con el fin de prevenir todo daño en el material, evite el riesgo de solidificación de los líquidos a bajas temperaturas y respecte los límites mínimo y máximo. No se puede realizar ninguna modificación en el material sin el acuerdo previo del fabricante o de su representante. Antes de proceder al montaje, despresurice las canalizaciones y realice una limpieza interna. Las electroválvulas pueden ser montadas en cualquier posición. El sentido de circulación del fluido está indicado por referencias en el cuerpo y en la documentación. La dimensión de las tuberías debe corresponder al racordaje indicado en el cuerpo, la etiqueta o la noticia. ATENCIÓN: • La reducción de las conexiones puede causar operaciones incorrectas o defectos de funcionamiento. • Para la protección del equipo se debe instalar en la parte de la entrada y tan cerca como sea posible del producto un filtro o tamizador adecuado para el servicio. • Si se utilizara cinta, pasta, spray u otros lubricantes en el ajuste, se debe evitar que entren partículas en el producto. • Se debe utilizar las herramientas adecuadas y colocar llaves lo más cerca posible del punto de conexión. • Para evitar daños al equipo, NO FORZAR las conexiones a la tubería. • No utilizar la válvula o el solenoide como palanca. • Las conexiones a la tubería no producirán ninguna fuerza, apriete o tensión sobre el producto. RUIDO DE FUNCIONAMIENTO El ruido de funcionamiento varia según la utilización, el fluido y el tipo de material utilizado. El usuario solamente podrá determinar con precisión el nivel sonoro emitido después de haber montado el componente en la instalación. MANTENIMIENTO El mantenimiento que necesitan los productos ASCO varia dependiendo de sus condiciones de utilización. Se recomienda realizar una limpieza periódica según la naturaleza del fluido, las condiciones de funcionamiento y el medio ambiente. Durante la intervención, los componentes deben ser examinados por si hubera desgastes excesivos.Se dispone de un juego completo de partes internas como recambio. En el caso de problemas durante el montaje/mantenimiento o en caso de duda, contacte con ASCO o sus representantes oficiales. DESMONTAJE Desmonte las piezas siguiendo el orden indicado en los dibujos de esta página. 1 - Soltar el clip de sujeción (1), manteniendo una presión hacia lo bajo, y soltar la bobina (2) (ver códigos bobinas, páginas siguientes) 2 - Retirar el resorte plano (10). 3 - Desatornille el conjunto tubo-culata (3) y sepárelo del cuerpo (4). 4 - Saque el conjunto núcleo resorte (5)(6) y la junta de estanuidad (8). 5 - Limpie o sustituya todas las piezas. MONTAJE Monte las piezas en el orden inverso al montaje. Compruebe que el clip de mantenimiento está correctamente posicionado, en la bobina (ver dibujo). La purga debe estar conectada para evitar toda polución interna de la electroválvula. NOTA : 1 - Lubrique la junta de estanquidad (8) y también, ligeramente, el diámetro exterior del núcleo con un aceite conforme a las normas AFNOR ISO TR 3498 categoría HL y FC. 2 - Compruebe el correcto apriete del conjunto tubo-culata, par de apriete (a). 3 - Vuelva a colocar la arandela resorte, la bobina y el clip de sujeción. Conecte el conjunto del conector. 4 - Después del montaje, haga funcionar la electroválvula varias veces con el fin de comprobar que se abren y cierran correctamente. 5 - Monte los racores de tubería, par de apriete máximo entre 5 y 7 Nm. CONEXIÓN ELÉCTRICA Las conexiones eléctrica deberan realizarse por personal cualificado y según las normas y reglamentos locales. ATENCIÓN: • Antes de comenzar el trabajo, desconecte el suministro de energía eléctrica y desenergice el circuito electrónico y los elementos portadores de tensión. • Todos los terminales eléctricos deben estar apretados adecuadamente según normas antes de su puesta en servicio. • Según el voltaje, los componentes electrónicos deben disponer de una conexión a tierra y satisfacer las normas y regulaciones locales. • Con el fin de asegurar la continuidad de masa de la bobina, compruebe su correcta colocación durante el montaje/ desmontaje. (ref. 1) La conexión eléctrica se realiza mediante: • Conector desenchufable ISO 4400 / EN 175301-803, forma A (Cuando la conexión se ha realizado correctamente y el modelo de conector suministrado o seleccionado es IP65 o IP67, entonces el grado de protección de la electroválvula es IP65 o IP67). 5 524685-001 Istruzioni di installazione e manutenzione Elettrovalvole 3/2 NC-NO-U, a comando diretto corpo in ottone o acciaio inox 1/8 - 1/4, serie 314 DESCRIZIONE Serie 314, 3/2 NC-NA: • Elettrovalvole con raccordi filettati 1/8-1/4. Corpo in ottone o acciaio inox. Bobine: Tutti e 238 i numeri di base sono approvati da UL e CSA e contrassegnati dagli appropriati logo UL e CSA. Versioni ATEX: Vedere “Condizioni particolari per un uso sicuro”. Installatie- en onderhoudsinstructies 2 2 3 1 3 1 3 2 IT MESSA IN FUNZIONE Prima di mettere il circuito sotto pressione, eseguire una prova elettrica. Nel caso delle elettrovalvole, mettere sotto tensione la bobina alcune volte e prestare attenzione allo scatto metallico che indica il funzionamento del solenoide. FUNZIONE Le elettrovalvole sono generalmente provviste di bobine per il funzionamento continuo. Per evitare il rischio di lesioni personali, non toccare la testa magnetica che può riscaldarsi durante il normale funzionamento. Se l’elettrovalvola è facilmente accessibile, l’installatore deve predisporre mezzi di protezione contro il contatto accidentale. Le nostre elettrovalvole ed elettrovalvole pilota sono progettate per funzionare con dispositivi conformi alle norme EN 61131-2. CONDIZIONI PARTICOLARI PER UN USO SICURO Per le teste magnetiche secondo ATEX, le istruzioni per l'uso contenute nelle istruzioni di installazione specifiche fornite con il prodotto, devono essere scrupolosamente osservate. Elettrovalvole con raccordi filettati: versioni standard, o versioni provviste di teste magnetiche, Ex d, Ex e mb, Ex mb, Ex tc (SG), per l'uso in atmosfere pericolose secondo ATEXIECEx. EMISSIONE SONORA L’emissione sonora dipende dall’applicazione, dal fluido controllato e dal tipo di apparecchiatura utilizzato. Il livello sonoro può essere determinato con esattezza solo con la valvola installata nel sistema. MONTAGGIO L'utilizzo dei componenti ASCO deve essere conforme ai dati tecnici riportati sulla targhetta o nella documentazione del componente. Per prevenire danni all'apparecchiatura, evitare che il liquido si solidifichi a bassa temperatura e rispettare i limiti di temperatura massimo e minimo. Eventuali modifiche dell'apparecchiatura sono ammesse solo se autorizzate dal produttore o da un suo rappresentante. Prima dell'installazione, depressurizzare il sistema di tubazioni ed eseguire la pulizia interna. Possibilità di montaggio delle elettrovalvole in tutte le posizioni senza effetti sul funzionamento. La direzione di flusso è indicata dalle marcature sul corpo della valvola e nella documentazione. Le connessioni di raccordo devono corrispondere alle dimensioni indicate sul corpo, sull'etichetta o nella brochure del prodotto. ATTENZIONE : • La riduzione delle dimensioni dei raccordi può causare anomalie di funzionamento. • Per proteggere l’apparecchiatura, installare un filtro adatto al servizio previsto sul lato di entrata, quanto più vicino possibile al prodotto. • Se si utilizza nastro, pasta, spray o lubrificante simile per il serraggio, evitare l’ingresso di particelle nel sistema. • Utilizzare attrezzi idonei e collocare le chiavi quanto più vicino possibile al punto di raccordo. • Per evitare danni all’apparecchiatura, NON STRINGERE ECCESSIVAMENTE le connessioni di raccordo. Applicare una coppia di serraggio massima da 5 a 7 Nm. • Non utilizzare la valvola o la testa magnetica come. • Le connessioni di raccordo non devono esercitare forza, coppia o tensione sul prodotto. MANUTENZIONE La manutenzione dei prodotti ASCO dipende dalle condizioni di servizio. È raccomandata la pulizia periodica la cui frequenza dipende dai fluidi utilizzati e dalle condizioni di servizio. Durante la manutenzione, deve essere verificata l’usura dei componenti. È disponibile una serie completa di componenti interni da utilizzare come kit di ricambio o di ricostruzione. In caso di problemi durante l’installazione/la manutenzione o in caso di dubbio, contattare ASCO o un suo rappresentante autorizzato. SMONTAGGIO Smontare le parti nell'ordine indicato negli schemi sulle presenti Istruzioni di Installazione e Manutenzione 1 - Rimuovere la clip di fissaggio (1), facendo pressione verso il basso, e la bobina (2) (vedere i codici delle bobine nelle pagine seguenti). 2 - Rimuovere la molla piatta (10). 3 - Svitare il cannotto (3) e separarlo dal corpo (4). 4 - Rimuovere l’unità nucleo mobile/molla (5)(6) e la guarnizione (8). 5 - Pulire o sostituire tutte le parti. RIMONTAGGIO Rimontare le parti in ordine inverso rispetto allo smontaggio. Verificare che la clip di fissaggio sia correttamente posizionata sulla bobina (vedere disegno). Lo scarico deve essere raccordato per evitare la contaminazione dell’interno dell’elettrovalvola. NOTA: 1 - Ingrassare la guarnizione (8) e ricoprire la circonferenza esterna del nucleo mobile con un leggero strato di lubrificante a norma AFNOR ISO TR 3498 categorie HL e FC. 2 - Verificare che il cannotto sia serrato a una coppia (a). 3 - Rimontare la ghiera, la bobina e la clip di fissaggio. Collegare il gruppo connettore. 4 - Dopo il rimontaggio, azionare ripetutamente l’elettrovalvola per verificare che le valvole si aprano e chiudano correttamente. 5 - Rimontare le connessioni di raccordo e serrare a una coppia massima da 5 a 7 Nm. CONNESSIONE ELETTRICA Tutti i collegamenti elettrici devono essere eseguiti esclusivamente da personale addestrato e qualificato ed essere conformi ai regolamenti e alle norme locali. ATTENZIONE • Prima di qualsiasi intervento, disinserire l’alimentazione elettrica dei componenti. • Tutti i morsetti a vite devono essere opportunamente serrati prima della messa in funzione. • I componenti elettrici devono essere messi a terra in conformità alle norme e ai regolamenti locali, secondo la tensione di alimentazione. • Per garantire la continuità a terra della bobina, verificare che questa sia correttamente posizionata durante il montaggio/ lo smontaggio (n. 1). Il collegamento elettrico dell’apparecchiatura è realizzato come indicato di seguito: • Connettore disinnestabile secondo ISO 4400 / EN 175301803, forma A (Quando la connessione viene effettuata correttamente e il connettore fornito o selezionato è IP65 o IP67, l’elettrovalvola avrà il grado di protezione IP65 o IP67). 6 524685-001 3/2 elektromagnetische kleppen NC-NO-U, directwerkend messing of roestvrijstalen behuizing, 1/8 - 1/4, serie 314 2 2 3 1 3 1 3 2 NL gebruikte (geleverde of gekozen) connector IP65- of IP67geklassificeerd is, heeft de magneetklep bescherming IP65 of IP67). BESCHRIJVING Serie 314, 3/2 NC-NO-U: • Elektromagnetische kleppen met getapte aansluitingen 1/81/4. Messing of roestvrijstalen. Spoelen: Alle 238 basisnummers zijn goedgekeurd door UL & CSA en voorzien van de desbetreffende UL- & CSA-logo's. ATEX versies: Zie “Speciale voorwaarden voor veilig gebruik”. INWERKINGSTELLING Voer, alvorens het circuit onder druk te zetten, een elektriciteitstest uit. Bij elektromagnetische kleppen activeert u de spoel een paar keer en hoort u een metaalachtige ‘’klik’’ die erop duidt dat de elektromagneet werkt. SPECIALE VOORWAARDEN VOOR VEILIG GEBRUIK Voor magneetkoppen volgens ATEX dienen de gebruiksinstructies die worden gegeven in de specifieke Installatieinstructies die worden meegeleverd met het product strikt te worden opgevolgd. Elektromagnetische kleppen met getapte aansluitingen: Standaardversies of versies voorzien van magneetkoppen, Ex d, Ex e mb, Ex mb, Ex tc (SG), voor gebruik in explosiegevaarlijke ruimten volgens ATEX-IECEx. FUNCTIE De meeste elektromagnetische kleppen zijn uitgerust met spoelen voor continubedrijf. Om het risico van persoonlijk letsel te voorkomen de magneetkop niet aanraken. Deze kan namelijk heet worden bij normaal gebruik. Als de elektromagnetische klep gemakkelijk toegankelijk is, dient de installateur te zorgen voor bescherming tegen onbedoeld contact. Onze magneetventielen en stuurventielen zijn ontwikkeld om te functioneren met apparatuur die voldoet aan de EN 61131-2 norm. MONTAGE Componenten van ASCO zijn uitsluitend bedoeld om te worden gebruikt binnen de technische specificaties zoals vermeld op de naamplaat of in de documentatie. Om schade aan de apparatuur te voorkomen, dient u ervoor te zorgen dat de vloeistof niet stolt bij lagere temperaturen en binnen de grenzen van de maximum- en minimumtemperatuur blijft. Wijzigingen aan de apparatuur mogen slechts worden uitgevoerd na raadpleging van de fabrikant of zijn vertegenwoordiger. Voor de installatie dient u het leidingenstelsel te ontluchten en vanbinnen te reinigen. De elektromagnetische kleppen kunnen in een willekeurige positie worden gemonteerd zonder de werking te beïnvloeden. De stroomrichting wordt aangegeven door markeringen op de klepbehuizing en in de documentatie. Buisaansluitingen dienen in overeenstemming te zijn met de grootte die wordt vermeld op de behuizing, het etiket of in de productbrochure. PAS OP: • Het beperken van de aansluitingen kan een onjuiste werking of storing veroorzaken. • Ter bescherming van de apparatuur dient u in de inlaatzijde zo dicht mogelijk bij het product een zeef of een filter te installeren die geschikt is voor de betreffende functie. • Indien tape, pasta of spray of een vergelijkbaar smeermiddel is gebruikt bij het aandraaien dient u te voorkomen dat deeltjes hiervan het systeem binnendringen. • Gebruik de juiste gereedschappen en plaats steeksleutels zo dicht mogelijk bij het aansluitpunt. • Om schade aan de apparatuur te voorkomen mag u de buisaansluitingen NIET TE STRAK AANDRAAIEN. Neem een maximaal aanhaalkoppel in acht van 5 tot 7 Nm. • Gebruik de klep of magneetkop niet als hefboom. • Buisaansluitingen mogen geen enkele kracht, wringing of druk uitoefenen op het product. GELUIDSEMISSIE De emissie van geluid is afhankelijk van de toepassing, de vloeistof en het type apparatuur dat wordt gebruikt. Het precieze geluidsniveau kan slechts worden bepaald door de gebruiker die de klep in zijn systeem heeft geïnstalleerd. ONDERHOUD Het onderhoud van producten van ASCO is afhankelijk van de gebruiksvoorwaarden. Het wordt aanbevolen periodiek te reinigen volgens een tijdschema dat afhankelijk is van de gebruikte vloeistoffen en de gebruiksvoorwaarden. Tijdens het onderhoud dienen de componenten te worden gecontroleerd op bovenmatige slijtage. Een complete set interne onderdelen is beschikbaar als reserveonderdelenkit of revisiekit. Als zich een probleem voordoet tijdens de installatie of het onderhoud of in geval van twijfel kunt u contact opnemen met ASCO of de erkende vertegenwoordigers. DEMONTAGE Demonteer de onderdelen in de volgorde die wordt aangegeven in de afbeeldingen in deze Installatie- en onderhoudsinstructies 1 - Verwijder de bevestigingsclip (1), blijf druk omlaag uitoefenen, en de spoel (2) (zie spoelcodes op de volgende pagina's). 2 - Verwijder de vlakke veer (10). 3 - Schroef de kern-buisunit los (3) en scheid deze van de behuizing (4). 4 - Verwijder de kern/veerunit (5)(6) en de afdichting (8). 5 - Reinig of vervang alle onderdelen. HERMONTAGE Hermonteer de onderdelen in omgekeerde volgorde als de demontage. Controleer of de borgclip juist is gepositioneerd op de spoel (zie tekening). De uitlaat dient aangesloten te zijn om verontreiniging van de binnenkant van de elektromagnetische klep te voorkomen. OPMERKING: 1 - Smeer de afdichting (8) en coat de buitenomtrek van de kern licht met een smeermiddel conform de norm AFNOR ISO TR 3498 categorie HL en FC. 2 - Controleer of de kern-buisunit goed is vastgedraaid met een koppel (A). 3 - Monteer nu de veerring, de spoel en de bevestigingsclip. Sluit de steker weer aan. 4 - Activeer na de hermontage de elektromagnetische klep een paar keer om er zeker van te zijn dat de kleppen naar behoren open- en dichtgaan. 5 - Hermonteer de buisaansluitingen en draai deze vast met een maximumkoppel van 5 tot 7 Nm. ELEKTRISCHE AANSLUITING Alle elektrische aansluitingen mogen uitsluitend door opgeleid en gekwalificeerd personeel worden uitgevoerd en dienen in overeenstemming te zijn met de plaatselijke voorschriften en normen. PAS OP: • Schakel vóór iedere ingreep de elektrische stroom uit om de stroomtoevoer naar de componenten te verbreken. • Alle schroefklemmen dienen naar behoren te zijn aangedraaid voordat ze in werking worden gesteld. • Afhankelijk van de voltage dienen elektrische componenten te worden geaard volgens de plaatselijke normen en voorschriften. • Om continue aarding van de spoel te garanderen dient u ervoor te zorgen dat deze juist gepositioneerd is tijdens de montage/demontage (nr. 1). De apparatuur is als volgt elektrisch aangesloten: • Uitneembare connector volgens ISO 4400 / EN 175301803, formulier A (Mits correct aangesloten en indien de 7 524685-001 Installasjons- og vedlikeholdsinstrukser 3/2 magnetventiler NC-NO-U, direkte betjente med hus av messing eller rustfritt stål, 1/8 - 1/4, serie 314 2 2 3 1 3 1 3 2 NO SETTE I DRIFT Før kretsen settes under trykk må du utføre en elektrisk test. For magnetventiler skal du energisere spolen et par ganger og høre et metallklikk som signal på at elektromagneten virker. BESKRIVELSE Serie 314, 3/2 NC-NO-U: • Magnetventiler med gjengede 1/8-1/4 koplinger. Hus av messing eller rustfritt stål. Spoler: Alle 238 grunnleggende tallene er UL- og CSAgodkjent og henholdsvis merket med de riktige UL- og CSAlogoene. ATEX versions: Se ”Spesielle vilkår for sikker bruk”: FUNKSJON De fleste spoleventiler er utstyrt med spoler beregnet på kontinuerlig drift. For å redusere risikoen for personskade må man ikke berøre spoleoperatøren, som kan bli varm under normale driftsforhold. Hvis magnetventilen er lett tilgjengelig, må installatøren sette opp vern som forhindrer tilfeldig kontakt. Våre solenoid- og pilotventiler er utformet til å fungere sammen med enheter som er i samsvar med standard EN-61131-2. SPESIELLE VILKÅR FOR SIKKER BRUK For spoleoperatører i henhold til ATEX, må bruksanvisningen gitt i de spesifikke installasjonsinstruksene som kommer sammen med produktet strengt overholdes. Magnetventiler med gjengede koplinger: Standard versjoner eller versjoner utstyrt med spoleoperatører, Ex d, Ex e mb, Ex mb, Ex tc (SG), for bruk i eksplosive atmosfærer i henhold til ATEX-IECEx. STØY Støynivået avhenger av bruksområdet, væsken og typen utstyr som brukes. Nøyaktig fastsettelse av støynivået kan bare gjøres av brukeren som har ventilen installert i sitt system. MONTERING ASCO-komponenter er kun beregnet på bruk innenfor de tekniske karakteregenskapene som er spesifisert på navneplaten eller i dokumentasjonen. For å unngå skade på utstyret må du sørge for å forhindre at væsken går over til fast form ved lave temperaturer og holder seg innenfor grensene for maksimal- og minimumstemperatur. Modifikasjoner av utstyret må kun gjøres etter rådføring med produsenten eller hans representant. Før installering, må trykket reduseres og rørsystemet rengjøres innvendig. Magnetventilene kan monteres i enhver stilling uten at det påvirker driften. Strømningsretningen angis av merker på ventilhuset og i dokumentasjonen. Rørkoplinger må være i samsvar med størrelsen angitt på huset, merket eller i produktbrosjyren. OBS! • Reduksjon av koblingene kan føre til feil bruk eller svikt. • For å beskytte utstyret bør du installere en sil eller et filter som passer for betjening av inntaket så nært produktet som mulig. • Hvis det brukes tape, glassfuss, spray eller tilsvarende smøremiddel for stramming, må du unngå at det kommer partikler inn i systemet. • Bruk riktig verktøy og plasser nøkler så nær tilkoblingspunktet som mulig. • For å unngå skade på utstyret må rørkoblingene IKKE TREKKES TIL FOR STRAMT. Bruk et maksimalt tiltrekkningsmoment på 5 til 7 Nm. • Ikke bruk ventilen eller spoleoperatøren som vektstang. • Rørkoblinger må ikke legge noen vekt, moment eller belastning på produktet. VEDLIKEHOLD Vedlikehold av ASCO-produkter avhenger av betjeningsforholdene. Periodisk rengjøring anbefales. Tidspunktene for dette vil avhenge av væskene som brukes og serviceforholdene. Under service bør komponentene kontrolleres for overdreven slitasje. Et fullstendig sett med interne deler er tilgjengelig som et reservedels- eller ombyggingssett. Hvis det oppstår et problem under installasjon/vedlikehold eller hvis du er i tvil må du ikke nøle med å ta kontakt med ASCO eller dennes autoriserte representanter. DEMONTERING Demonter delene i den rekkefølgen som angis på snittene i disse installasjons- og vedlikeholdsinstruksene 1 - Fjern festeklemmen (1), oppretthold trykket nedover, og spolen (2) (se spolekoder på følgende sider). 2 - Fjern den flate fjæren (10). 3 - Skru av kjernerørdelen (3) og skill den fra huset (4). 4 - Fjern kjerne/fjær-enheten (5)(6) og tetningen (8). 5 - Rengjør eller skift ut alle deler. REMONTERING Monter komponentene i omvendt rekkefølge fra demontering. Sørg for at festeklemmen er korrekt posisjonert på spolen (se tegning). Utløpet må være tilkoplet for å forhindre forurensning av innsiden av magnetventilen. MERK: 1 - Ha fett på tetningen (8) og påfør den ytre omkretsen av kjernen med et smøremiddel som er i henhold til standarden AFNOR ISO TR 3498 kategoriene HL og FC. 2 - Sørg for at kjerne-rør-enheten trekkes korrekt til med et moment (a). 3 - Sett den flate fjæren, spolen og festeklemmen tilbake på plass. Koble til tilkoblingsmonteringen. 4 - Etter remontering skal du bruke magnetventilen flere ganger for å være sikker på at ventilene åpnes og lukkes som de skal. 5 - Sett rørkoblinger sammen på nytt og stram på et maksimalt dreiemoment på 5 til 7 Nm. ELEKTRISK TILKOBLING Alle elektriske koplinger må bare gjøres av faglig kvalifisert personale og må være i samsvar med lokale regler og standarder. OBS! • Før eventuelle inngrep må du slå av strømmen slik at komponentene slås av. • Alle skrueklemmer må strammes skikkelig før de tas i bruk. • Avhengig av spenningen må elektriske komponenter være jordet i henhold til lokale standarder og forskrifter. • For å sørge for god jording av spolen må du sørge for at den er korrekt posisjonert under montering/demontering (nr. 1). Utstyret er elektrisk tilkoplet som følger: • Løs kopling i henhold til ISO 4400 / EN 175301-803, form A (Ved riktig tilkobling og når (den leverte eller valgte) konnektoren i bruk har IP65- eller IP67 spesifikasjon, har solenoidventilen IP65- eller IP67- vern). 8 524685-001 Installations- och underhållsinstruktioner 3/2 solenoidventiler NC-NO-U, direktstyrda ventilkropp i mässing eller rostfri stål, 1/8 - 1/4, serie 314 BESKRIVNING Serie 314, 3/2 NC-NO-U: • Solenoidventiler med gängad 1/8-1/4 koppling. Kropp i mässing eller rostfri stål Spolar: Alla de 238 basnumren är UL- och CSA-godkända och märkta med tillämpliga UL- och CSA-logotyper. 2 2 3 1 3 1 3 2 SE DRIFTSSÄTTNING Utför en elektrisk test innan kretsen sätts under tryck. Vid användning av solenoidventiler, slå till spolen ett antal gånger och lägg märke till ett metalliskt klickljud vilket indikerar att solenoiden har aktiverats. FUNKTION De flesta solenoidventiler har spolar för kontinuerlig drift. För att förebygga risk för person- eller materialskada får solenoidoperatören inte vidröras då den kan bli mycket varm vid normal drift. Om solenoidventilen är lätt att komma åt ska installatören förse med skydd mot oavsiktlig kontakt. Våra solenoidventiler och pilotventiler är konstruerade för användning med enheter som överensstämmer med EN 61131-2-standarden. ATEX-versioner: Se “Särskilda villkor för säker användning”. SÄRSKILDA VILLKOR FÖR SÄKER ANVÄNDNING För solonoidoperatörer till ATEX, är det viktigt att strikt följa användningsinstruktionerna som levereras med produkten. Solenoidventiler med gängad koppling: Standard versioner eller versioner försedda med solenoidoperatörer, Ex d, Ex e mb, Ex mb, Ex tc (SG), för användning i explosiva omgivningar enligt ATEX-IECEx. BULLERNIVÅ Bullernivån är beroende på tillämpningen, vätsketyp och typ av utrustning. Den exakta bullernivån kan bara fastställas av användaren på platsen där ventilen installerats. MONTERING ASCO-komponenter är enbart avsedda för användning enligt de tekniska egenskaper som specificerats på namnplattan eller i dokumentation. Skydda utrustningen mot skador, låt inte vätskan stelna vid låg temperatur och se till att den hålls inom maximum och minimum temperaturgränser. Utrustningen får enbart modifieras med tillverkarens eller en representants uttryckliga medgivande. Före installationen ska trycket i ledningarna kopplas bort och rengöras invändigt. Solenoidventilerna kan monteras i valfri position utan att detta inverkar på funktionen. Flödesriktningen anges med markeringar på ventilkroppen och i dokumentationen. Rörkopplingarna ska göras enligt storleken som står angiven på kroppen, etiketten eller produktbladet. VARSAMHET: • Att minska antalet kopplingar kan förorsaka fel eller bristande funktion. • För att skydda utrustningen ska en lämplig sil eller ett filter installeras för intaget och så nära produkten som möjligt. • Var försiktig så att inga partiklar kommer in i systemet vid användning av tejp, fett, sprej eller liknande smörjmedel vid åtdragningen. • Använd rätt verktyg och placera alltid skiftnyckeln så nära kopplingspunkten som möjligt. • Undvik att skada utrustningen: DRA INTE ÅT RÖRKOPPLINGARNA FÖR HÅRT. Observera det maximala vridmomentet på 5 till 7 Nm. • Använd aldrig ventilen eller solenoidoperatören som en hävstång. • Rörkopplingar får inte utgöra en forcerande belastning på produkten. UNDERHÅLL Underhållet av ASCO-produkter är beroende på driftförhållandena. Regelbunden rengöring rekommenderas, intervallet är beroende på vätskan som används och driftförhållandena. Under driften ska komponenterna kontrolleras på slitage. En komplett uppsättning invändiga delar finns som reservdel eller reservdelssats. Om ett problem uppstår vid installation/ underhåll eller vid frågor, ta då gärna kontakt med ASCO eller en auktoriserad representant. ISÄRTAGNING Ta av delarna i den ordningsföljd som anges i figurerna i dessa Installations- och underhållsinstruktioner 1 - Ta bort fästklämman (1), bibehåll ett nedåtriktat tryck, och spolen (2) (se spolkoder på följande sidor). 2 - Ta bort den platta fjädern (10). 3 - Skruva loss kärnröret (3) och tar ut det ur ventilkroppen (4). 4 - Ta bort kärnan/fjäderenheten (5)(6) och o-ringen (8). 5 - Rengör eller byt ut alla delar. HOPSÄTTNING Sätt ihop delarna in omvänd ordningsföljd. Se till att klämman sitter på spolen ordentligt (se ritning). Utblåset måste kopplas så att inga föroreningar kan komma in i solenoidventilen. OBS! 1 - Smörj packningen (8) och förse kärnans yttre omkrets med ett tunt skikt fett enligt AFNOR ISO TR 3498 kategoriema HL och FC. 2 - Se till att kärnrörsenheten spänns fast ordentligt enligt vridmoment (a). 3 - Sätt tillbaka den platta fjädern, spolen och fästklämman. Anslut kopplingsenheten. 4 - Efter hopsättningen, testa solenoidventilens funktion flera gånger för att försäkra att ventilerna öppnar och stänger som de ska. 5 - Koppla ihop rörledningarna och spänn fast enligt det maximala vridmomentet på 5 till 7 Nm. ELEKTRISK ANSLUTNING Alla elektriska anslutningar ska utföras av behörig elektriker och i enlighet med gällande lokala standarder och bestämmelser. VARSAMHET: • Innan något utförs ska all strömförsörjning till komponenterna kopplas bort. • Alla elektriska skruvkontakter ska dras åt enligt anvisningarna innan produkten tas i bruk. • Beroende på strömspänning, ska elektriska komponenter jordas enligt lokala normer och regler. • För att försäkra om kontinuerlig jordning av spolen, se till att den placeras korrekt vid isättning/urtagning (nr. 1). Utrustningen har följande elektriska koppling: • Löstagbar koppling i enlighet med ISO 4400 / EN 175301-803, formulär A (Vid korrekt koppling och när (den levererade eller valda) kopplingen är IP65- eller IP67-märkt, är solenoidventilen skyddad enligt typ IP65 eller IP67). 9 524685-001 Asennus- ja huolto-ohjeet 3/2-solenoidiventtiilit NC-NO-U, suoratoiminen runko messinkiä tai ruostumatonta terästä, 1/8 - 1/4, sarja 314 KUVAUS Sarja 314, 3/2 NC-NO-U: • Solenoidiventtiilit, joissa on 1/8-1/4-kierreliitännät. Runko messinkiä tai ruostumatonta terästä. Kelat: Kaikki 238 perusnumeroa ovat UL- ja CSA-hyväksyttyjä, ja ne on merkitty asianomaisilla UL:n ja CSA:n logoilla. ATEX-direktiivin mukaiset versiot: Katso kohta Turvalliset käyttöolosuhteet. 2 2 3 1 3 1 3 2 FI KÄYTTÖÖNOTTO Tee sähkömittaukset ennen piirin paineistamista. Johda solenoidiventtiileihin muutaman kerran jännite. Metallinen napsahdus merkitsee, että solenoidi toimii. TOIMINTA Useimmissa solenoidiventtiileissä on jatkuvaa toimintaa varten suunnitellut käämit. Henkilövahingon ehkäisemiseksi älä kosketa solenoidikäyttölaitetta, joka voi kuumentua normaaleissa käyttöolosuhteissa. Jos solenoidiventtiiliin on vaivaton päästä käsiksi, asentajan on järjestettävä riittävä suojaus tahattoman kosketuksen estämiseksi. Magneetti- ja pilottiventtiilimme on suunniteltu toimimaan standardin EN 61131-2 mukaisten laitteiden kanssa. TURVALLISET KÄYTTÖOLOSUHTEET ATEX-direktiivin mukaisten solenoidikäyttölaitteiden mukana toimitettuja asennusohjeita on ehdottomasti noudatettava. Solenoidiventtiilit, joissa on -kierreliitännät: Standardinmukaiset versiot tai versiot, joissa on solenoidikäyttölaitteet, Ex d, Ex e mb, Ex mb, Ex tc (SG), tarkoitettu käytettäväksi räjähdysvaarallisissa ympäristöissä ATEX-IECEx-standardin mukaisesti. ÄÄNET Venttiilistä kuuluvat äänet määräytyvät käyttösovelluksen, virtaavan aineen ja käytetyn laitetyypin mukaan. Vain käyttäjä voi määrittää äänitason tarkasti, kun venttiili on asennettu järjestelmään. ASENTAMINEN ASCO-osat on tarkoitettu käytettäväksi vain tyyppikilvessä tai asiakirjoissa määriteltyjen teknisten ominaisuuksien mukaisesti. Jotta laitteisto ei vahingoittuisi, varmista, että nestemäinen aine ei kiinteydy alhaisissa lämpötiloissa ja että ympäröivä lämpötila ei ylitä suositeltua vähimmäis- tai enimmäislämpötilaa. Tuotteisiin saa tehdä muutoksia vain valmistajan tai valmistajan edustajan luvalla. Poista putkista paine ja puhdista sisäpuoli ennen asentamista. Solenoidiventtiilit voidaan asentaa mihin asentoon tahansa. Virtauksen suunta on merkitty venttiilin runkoon ja käyttöohjeisiin. Putkiliitäntöjen on oltava yhdenmukaiset rungossa, tarrassa tai tuote-esitteessä olevien kokomerkintöjen kanssa. TÄRKEÄÄ: • Liitäntöjen vähentäminen saattaa aiheuttaa toimintahäiriöitä. • Suojaa laitteisto asentamalla käyttötarkoitukseen sopiva sihti tai suodatin aukon puolelle mahdollisimman lähelle tuotetta. • Jos kiristämisessä käytetään teippiä, massaa, suihketta tai vastaavaa voiteluainetta, vältä hiukkasten pääsemistä järjestelmään. • Käytä sopivia työkaluja ja aseta vääntöavaimet mahdollisimman lähelle liitäntäkohtaa. • ÄLÄ KIRISTÄ PUTKILIITÄNTÖJÄ LIIKAA laitevaurion välttämiseksi. Huomioi kiristysmomentti 5–7 Nm. • Älä käytä venttiiliä tai solenoidikäyttölaitetta vipuna. • Putkiliitäntöjen ei tule kohdistaa tuotteeseen voimaa, vääntöä tai rasitusta. HUOLTO ASCO-tuotteiden huolto riippuu käyttöolosuhteista. Säännöllinen puhdistaminen, jonka ajoitus riippuu nesteistä ja käyttöolosuhteista, on suositeltavaa. Huollon aikana on tarkistettava, ovatko osat kuluneet liikaa. Varaosa- ja korjaussarjana on saatavana täydellinen sarja sisäosia. Mikäli asennuksen/ huollon yhteydessä tulee ongelmia tai mikäli olet epävarma, ota yhteys ASCOiin tai valtuutettuun edustajaan. PURKAMINEN Pura osat näissä asennus- ja huolto-ohjeissa ilmoitetussa järjestyksessä. 1 - Irrota kiinnityssinkilä (1), ylläpidä painetta alaspäin, ja käämi (2) (katso käämin koodit "LIITÄNTÄ"-sivulta). 2 - Irrota lattajousi (10). 3 - Ruuvaa irti ydinputkiyksikkö () ja irrota se rungosta (4). 4 - Poista ydin-/jousiyksikkö (5)(6) ja tiiviste (8). 5 - Puhdista tai vaihda kaikki osat. KOKOAMINEN Kokoa osat uudelleen käänteisessä järjestyksessä. Varmista, että kiinnityssinkilä on oikeassa asennossa käämissä (katso kuva). Poistosuojuksilla on estettävä solenoidiventtiilin sisäosien likaantuminen. HUOM. 1 - Rasvaa tiiviste (8) ja voitele ytimen ulkokehä kevyesti standardin AFNOR ISO TR 3498 luokkien HL ja FC mukaisella voiteluaineella. 2 - Varmista, että ydinputkiyksikkö on kiristetty kunnolla kiristysmomenttiin (a). 3 - Asenna lattajousi, käämi ja kiinnityssinkilä takaisin paikalleen. Yhdistä liitinyksikkö. 4 - Käytä solenoidiventtiiliä monta kertaa uudelleenkokoamisen jälkeen, jotta voit varmistaa, että venttiilit avautuvat ja sulkeutuvat kunnolla. 5 - Kokoa uudelleen putkiliitännät ja kiristä ne enintään 5–7 Nm:n kiristysmomenttiin. SÄHKÖLIITÄNTÄ Sähköliitännät on annettava pätevien henkilöiden tehtäväksi paikallisten standardien ja määräysten mukaisesti. TÄRKEÄÄ: • Katkaise osien virransyöttö ennen asennuksen aloittamista. • Kaikki ruuviliitokset on kiristettävä kunnolla ennen käyttöä. • Sähköliitännät on maadoitettava paikallisten standardien ja säännösten ja jännitteen mukaisesti. • Varmista käämin maadoitus tarkistamalla, että käämi on sijoitettu oikein asennuksen/purkamisen aikana (nro 1). Laitteiston sähköliitännät: • Irrotettava liitin EN 175301-803, form A (Asianmukaisessa liitännässä tai käytettävän (mukana tulleen tai valitun) liittimen luokituksen ollessa IP65 tai IP67 solenoidiventtiilillä on IP65- tai IP67-suojaus). 10 524685-001 Installations- og vedligeholdelsesvejledning 3/2 magnetventiler NC-NO-U med direkte betjening og hus af messing eller rustfrit stål, 1/8 - 1/4, serie 314 BESKRIVELSE Serie 314, 3/2 NC-NO-U: • Magnetventiler med 1/8-1/4 gevindforbindelser. Hus af messing eller rustfrit stål. Spoler: Alle 238 basisnumre er UL- og CSA-godkendte og mærket med de pågældende UL- og CSA-logoer. ATEX-versioner: Se “Særlige krav til sikker brug”. 2 2 3 1 3 1 3 2 DK START AF DRIFT Udfør en elektrisk test, inden der bliver sat tryk på kredsløbet. Ved magnetventiler aktiveres spolen nogle få gange, og der lyttes efter et metalklik, som betyder, at magneten fungerer. FUNKTION De fleste magnetventiler er udstyret med spoler, der er konstrueret til kontinuerlig drift. For at forebygge personskader må magnetstyreenheden, som kan blive meget varm under normale driftsbetingelser, ikke berøres. Hvis der er let adgang til magnetventilen, skal installatøren sørge for, at det ikke er muligt at berøre den ved et uheld. Vores solenoideventiler og pilotventiler er beregnet til at fungere sammen med enheder, der opfylder standarderne i henhold til EN 61131-2. SÆRLIGE KRAV TIL SIKKER BRUG For så vidt angår magnetstyreenheder til ATEX skal instruktionerne i den installationsvejledning, der følger med produktet, følges nøje. Magnetventiler med gevindforbindelser: Almindelige versioner eller versioner, der er forsynet med magnetstyreenheder, Ex d, Ex e mb, Ex mb, Ex tc (SG), til anvendelse til ATEX-IECEx i eksplosionsfarlige omgivelser. LYD Udsendelsen af lyd afhænger af brugen, væsken og den type udstyr, der anvendes. En nøjagtig fastlæggelse af lydniveauet kan kun foretages af den bruger, der har ventilen installeret i sit system. MONTERING ASCO-komponenter er kun beregnet til brug under de tekniske vilkår, der er beskrevet på typepladen eller i dokumentationen. For at undgå beskadigelse af udstyret skal det sikres, at væsken ikke kan størkne ved lave temperaturer, og at de gældende grænser for maksimum- og minimumtemperatur overholdes. Ændringer på udstyret må kun foretages efter samråd med producenten eller dennes repræsentanter. Udløs trykket i rørsystemet og rens det indvendigt før installationen. Magnetventilerne kan monteres i alle positioner, uden at det påvirker driften. Strømningsretningen er angivet med markeringer på ventilhuset og i dokumentationen. Rørforbindelser skal stemme overens med den størrelse, der er angivet på huset, mærkningen eller produktets indlægsseddel. FORSIGTIG: • Reducering af forbindelserne kan forårsage forkert funktion eller fejl. • Til beskyttelse af udstyret kan der i indløbssiden så tæt på produktet som muligt installeres en si eller et filter, der er egnet til formålet. • Pas på, at der ikke kommer partikler ind i systemet, hvis der bruges tape, pasta, spray eller et lignende smøremiddel i forbindelse med tilspændingen. • Brug det korrekte værktøj og brug skruenøglerne så tæt på samlingspunktet som muligt. • For at undgå beskadigelse af udstyret må rørforbindelserne IKKE OVERSPÆNDES. Et maksimalt tilspændingsmoment på 5 til 7 Nm skal overholdes. • Brug ikke ventilen eller magnetstyreenheden som løftegreb. • Rørforbindelserne må ikke udøve nogen kraft, vridningsmoment eller belastning på produktet. VEDLIGEHOLDELSE Vedligeholdelsen af ASCO-produkter afhænger af brugsbetingelserne. Regelmæssig afrensning anbefales; hvor ofte afhænger af de anvendte væsker og brugsbetingelserne. Under vedligeholdsarbejdet skal komponenterne ses efter for unormalt kraftig slitage. Et komplet sæt med de indvendige dele kan fås som reservedelssæt eller genopbygningssæt. Kontant ASCO eller en autoriseret repræsentant, hvis der opstår problemer under installation/vedligeholdelse eller i tvivlstilfælde.. DEMONTERING Adskil delene i den rækkefølge, der er angivet på tegningerne i denne Installations- og vedligeholdelsesvejledning. 1 - Fjern fastholdelsesklipsen (1), fasthold trykket nedad, og spolen (2) (se spolekoder på følgende sider). 2 - Fjern den flade fjeder (10). 3 - Skru kernerørsenheden (3) af og adskil den fra huset (4). 4 - Fjern kerne/fjederenhed (5)(6) og pakning (8). 5 - Rengør eller udskift alle dele. REMONTERING Saml delene igen i omvendt rækkefølge af demonteringen. Kontrollér, at holdeklemmen er korrekt anbragt på spolen (se tegningen). Udløbet skal være tilsluttet for at forhindre kontaminering af indersiden af magnetventilen. BEMÆRK: 1 - Smør pakningen (8) og læg et tyndt lag smøremiddel på den udvendige omkreds af kernen. Dette smøremiddel skal opfylde standarden AFNOR ISO TR 3498, kategori HL og FC. 2 - Sørg for, at kernerørsenheden er korrekt tilspændt med et tilspændingsmoment (A). 3 - Sæt den flade fjeder, spolen og fastholdelsesklipsen på plads igen. Forbind stikenheden. 4 - Kør magnetventilen flere gange efter remontering for at sikre, at ventilerne åbner og lukker korrekt. 5 - Saml rørforbindelserne igen og spænd dem ved et maksimalt tilspændingsmoment på 5 til 7 Nm. ELEKTRISK INSTALLATION Alle elektriske tilslutninger må kun foretages af personale med erfaring og uddannelse til formålet og skal foretages i overensstemmelse med de lokale bestemmelser og standarder. FORSIGTIG: • Sluk for strømmen til komponenterne, inden der foretages nogen form for indgriben. • Alle skrueklemmer skal være spændt ordentligt inden ibrugtagning. • De elektriske komponenter skal være jordforbundne i overensstemmelse med lokale standarder og bestemmelser og alt afhængigt af spændingen. • Af hensyn til spolens jordkontinuitet skal det sikres, at den placeres korrekt under montering/demontering (nr. 1). Udstyret forbindes elektrisk som følger: • Aftagelig konnektor til ISO 4400 / EN 175301-803, type A (Efter korrekt tilslutning og når det - medfølgende eller valgte - stik er kapslingsklasse IP65 eller IP67, vil solenoideventilen have IP65- eller IP67-beskyttelse). 11 524685-001 Instruções de instalação e manutenção Válvulas solenóides 3/2 NC-NO-U, corpo de aço inoxidável ou latão, directas, 1/8 - 1/4, séries 314 DESCRIÇÃO Série 262, 3/2 NC-NO-U: • Válvulas solenóides com ligações de rosca de 1/8-1/4. Corpo em latão ou aço inoxidável. Bobinas: Todos os 238 números básicos estão aprovados pela UL & CSA e marcados com os logótipos UL & CSA adequados. Versões ATEX: Consulte as “Condições especiais para utilização segura”. 2 2 3 1 3 1 3 2 PT COLOCAÇÃO EM FUNCIONAMENTO Antes de pressurizar o circuito, efectue um teste eléctrico. No caso das válvulas solenóides, estimule a bobina algumas vezes e observe um clique metálico que significa que a solenóide está a funcionar. FUNCIONAMENTO A maior parte das válvulas de solenóide está equipada com bobinas concebidas para trabalho contínuo. Para evitar lesões corporais, não toque no operador de solenóide que pode ficar quente em condições de funcionamento normais. Se a válvula solenóide tiver acesso fácil, o instalador deve utilizar equipamento de protecção para evitar qualquer contacto acidental. As nossas electroválvulas e electroválvulas-piloto foram concebidas para funcionar com os dispositivos conforme a norma EN 61131-2. CONDIÇÕES ESPECIAIS PARA UTILIZAÇÃO SEGURA Para operadores de solenóide para ATEX, as instruções de utilização fornecidas nas instruções de instalação específicas fornecidas com o produto têm de ser cumpridas. Válvulas solenóides com ligações de rosca: Versões standard ou versões equipadas com operadores de solenóide, Ex d, Ex e mb, Ex mb, Ex tc (SG), para utilização em atmosferas explosivas para ATEX-IECEx. MONTAGEM Os componentes da ASCO devem ser utilizados apenas de acordo com as características técnicas especificadas na placa de identificação ou na documentação. Para evitar danos no equipamento, certifique-se de que impede o líquido de solidificar a baixas temperaturas e que permanece dentro dos limites de temperatura mínimos e máximos. As modificações ao equipamento só podem ser efectuadas após consulta ao fabricante ou ao seu representante. Antes da instalação, despressurize o sistema de tubos e limpe o interior. As válvulas solenóides podem ser montadas em qualquer posição sem afectar o funcionamento. A direcção do caudal é indicada pelas marcas no corpo da válvula e na documentação. As ligações dos tubos têm de estar de acordo com o tamanho indicado no corpo, etiqueta ou no folheto do produto. ATENÇÃO: • A redução das ligações pode provocar um funcionamento inadequado ou uma avaria. • Para protecção do equipamento, instale uma rede ou um filtro adequado para a assistência relacionada com o lado de entrada o mais junto possível do produto. • Quando utilizar fita adesiva, pasta, spray ou um lubrificante idêntico para apertar, evite a entrada de partículas no sistema. • Utilize as ferramentas adequadas e coloque as chaves de bocas o mais junto possível do ponto de ligação. • Para evitar danos no equipamento, NÃO APERTE EXCESSIVAMENTE as ligações do tubo. Cumpra um binário de aperto máximo de 5 a 7 Nm. • Não utilize a válvula nem o operador de solenóide como uma alavanca. • As ligações do tubo não devem exercer qualquer força, binário ou esforço no produto. EMISSÃO DE SOM A emissão de som depende da aplicação, fluído e tipo de equipamento utilizado. A determinação exacta do nível de som só pode ser efectuada pelo utilizador com a válvula instalada no sistema. MANUTENÇÃO A manutenção dos produtos da ASCO depende das condições de serviço. A limpeza periódica é recomendada e o momento da limpeza depende dos fluidos utilizados e das condições de assistência. Deve verificar se os componentes têm um desgaste excessivo durante a assistência. Um conjunto completo de peças internas está disponível como um kit de peças sobresselentes ou reconstruídas. Se surgir algum problema durante a instalação/manutenção ou no caso de dúvidas, contacte a ASCO ou um representante autorizado. DESMONTAGEM Desmonte as peças pela ordem indicada nas vistas destas Instruções de I&M 1 - Remova a braçadeira de fixação (1),manter a pressão para baixo e a bobina (2) (ver o códigos das bobinas nas páginas seguintes). 2 - Remover a mola plana (10). 3 - Desaparafuse o tubo do núcleo (3) e separe-o do corpo (4). 4 - Remova o núcleo/mola (5)(6) e o vedante (8). 5 - Limpe ou substitua todas as peças. MONTAGEM Monte as peças pela ordem inversa de desmontagem. Certifique-se de que a braçadeira de fixação está correctamente colocada na bobina (ver desenho). A saída tem de estar ligada para impedir a contaminação do interior da válvula solenóide. NOTA: 1 - Lubrifique o vedante (8) e revista a circunferência exterior do núcleo com um lubrificante em conformidade com a norma AFNOR ISO TR 3498 categorias HL e FC. 2 - Certifique-se de que o tubo do núcleo está apertado correctamente com um binário (a). 3 - Substituir a mola plana, a bobina e o clip de retenção. Ligar o conector. 4 - Depois da montagem, opere a válvula solenóide várias vezes para garantir que as válvulas abrem e fecham correctamente. 5 - Monte das ligações dos tubos e aperte com um binário máximo de 5 a 7 Nm. LIGAÇÃO ELÉCTRICA Todas as ligações eléctricas têm de ser efectuadas por pessoal especializado e qualificado e têm de estar de acordo com as normas e os regulamentos locais. ATENÇÃO: • Antes de efectuar qualquer intervenção, desligue a corrente eléctrica para desactivar os componentes. • Todos os terminais dos parafusos têm de ser apertados correctamente antes de serem utilizados. • Dependendo da voltagem, os componentes eléctricos têm de ser ligados à terra de acordo com os regulamentos e as normas locais. • Para garantir a continuidade de terra da bobina, certifique-se de que está posicionada correctamente durante a montagem/ desmontagem (nº 1). O equipamento é ligado electricamente da seguinte forma: • Conector amovível para ISO 4400 / EN 175301-803, forma A (Quando a conexão é correctamente efectuada e quando o conector (fornecido ou seleccionado) usado é IP65 ou IP67, o grau de protecção da electroválvula será IP65 ou IP67). 12 524685-001 Οδηγίες εγκατάστασης και συντήρησης 3/2 ηλεκτρομαγνητικές βαλβίδες NC-NO-U, με απευθείας χειρισμό σώμα από ορείχαλκο ή ανοξείδωτο ατσάλι, 1/8 - 1/4, σειρά 314 2 2 3 1 3 1 3 2 GR ή επιλεγμένος) σύνδεσμος που χρησιμοποιείτε είναι προδιαγραφών IP65- ή -IP67, η ηλεκτροβαλβίδα θα είναι διαθέτει προστασία προδιαγραφών IP65 ή IP67). ΠΕΡΙΓΡΑΦΗ Έκδοση/ 314, 3/2 NC-NO-U: • Ηλεκτρομαγνητικές βαλβίδες με κοχλιωτές συνδέσεις 1/8-1/4. Σώμα από ορείχαλκο ή ανοξείδωτο ατσάλι. Πηνία: Και τα 238 βασικά νούμερα έχουν εγκριθεί από τα UL & CSA και φέρουν σήμανση με τα δέοντα λογότυπα των UL & CSA. Τύποι συσκευής σύμφωνοι με: Δείτε “Ειδικές συνθήκες για ασφαλή χρήση”. ΔΟΚΙΜΑΣΤΙΚΗ ΛΕΙΤΟΥΡΓΙΑ Προτού αποσυμπιέσετε το κύκλωμα, πραγματοποιήστε ένα ηλεκτρολογικό έλεγχο. Στην περίπτωση των ηλεκτρομαγνητικών βαλβίδων, ενεργοποιήστε το πηνίο μερικές φορές ώστε να ακούσετε ένα μεταλλικό “κλικ” που σημαίνει ότι η ηλεκτρομαγνητική κεφαλή λειτουργεί. ΛΕΙΤΟΥΡΓΙΑ Οι περισσότερες ηλεκτρομαγνητικές βαλβίδες είναι εξοπλισμένες με πηνία για λειτουργία υπό διαρκή τάση. Για να αποφύγετε τον κίνδυνο τραυματισμού, μην αγγίζετε την ηλεκτρομαγνητική κεφαλή η οποία μπορεί να υπερθερμανθεί ακόμα και υπό φυσιολογικές συνθήκες λειτουργίας. Εάν υπάρχει εύκολη πρόσβαση στην ηλεκτρομαγνητική βαλβίδα, ο υπεύθυνος για την τοποθέτηση θα πρέπει να λάβει την κατάλληλη προστασία κατά της ακούσιας επαφής. Οι ηλεκτροβαλβίδες και οι πιλοτικές βαλβίδες μας είναι σχεδιασμένες έτσι ώστε να συνεργάζονται με συσκευές που συμμορφώνονται με το πρότυπο EN 61131-2. ΕΚΠΟΜΠΗ ΗΧΟΥ Η εκπομπή ήχου διαφέρει ανάλογα με την εφαρμογή, το υγρό και τον τύπο του εξοπλισμού που χρησιμοποιείται. Ο χρήστης δεν μπορεί να πραγματοποιήσει ακριβή καθορισμό του επιπέδου ήχου παρά μόνο αφού εγκαταστήσει τη βαλβίδα στο σύστημά του. ΣΥΝΤΗΡΗΣΗ Η συντήρηση των προϊόντων ASCO εξαρτάται από τις συνθήκες λειτουργίας. Συνιστάται περιοδικός καθαρισμός, το χρονικό διάστημα του οποίου θα εξαρτηθεί από τα χρησιμοποιούμενα υγρά και της συνθήκες λειτουργίας. Κατά τη συντήρηση, πρέπει να πραγματοποιείται έλεγχος των εξαρτημάτων για υπερβολική φθορά. Διατίθεται πλήρες σύνολο εσωτερικών εξαρτημάτων ως ανταλλακτικά ή εξαρτήματα ανακατασκευής. Εάν προκύψει κάποιο πρόβλημα κατά την εγκατάσταση/συντήρηση ή εάν παρουσιαστούν απορίες, επικοινωνήστε με την ASCO ή με τους εξουσιοδοτημένους αντιπροσώπους της. ΕΙΔΙΚΕΣ ΣΥΝΘΗΚΕΣ ΓΙΑ ΑΣΦΑΛΗ ΧΡΗΣΗ Όπως προβλέπεται από την οδηγία ATEX σχετικά με ηλεκτρομαγνητικές κεφαλές, πρέπει να τηρούνται αυστηρά οι οδηγίες χρήσης που συνοδεύουν τις συγκεκριμένες Οδηγίες εγκατάστασης που συνοδεύουν το προϊόν. Ηλεκτρομαγνητικές βαλβίδες με κοχλιωτές συνδέσεις: Οι βασικές εκδόσεις με βαθμό προστασίας ή οι εκδόσεις που έχουν εξοπλιστεί με ηλεκτρομαγνητικές κεφαλές, Ex d, Ex e mb, Ex mb, Ex tc (SG), για χρήση σε εκρήξιμη ατμόσφαιρα σύμφωνα με την οδηγία ATEX-IECEx. ΣΥΝΑΡΜΟΛΟΓΗΣΗ Τα εξαρτήματα ASCO προορίζονται για χρήση μόνο σε τεχνικά χαρακτηριστικά που αναγράφονται στην ετικέτα ή στα συνοδευόμενα έγγραφα. Για να αποφύγετε τυχόν βλάβη του εξοπλισμού, φροντίστε να αποφύγετε τη στερεοποίηση του υγρού σε χαμηλές θερμοκρασίες και βεβαιωθείτε ότι τηρείτε τα όρια μέγιστης και ελάχιστης θερμοκρασίας. Οποιεσδήποτε μετατροπές στον εξοπλισμό μπορούν να πραγματοποιηθούν μόνο αφού συμβουλευτείτε τον κατασκευαστή ή τον εμπορικό αντιπρόσωπό του. Πριν την εγκατάσταση, αποσυμπιέστε το σύστημα σωληνώσεων και καθαρίστε εσωτερικά. Οι ηλεκτρομαγνητικές βαλβίδες μπορούν να τοποθετηθούν σε οποιαδήποτε θέση χωρίς να επηρεάζουν τη λειτουργία. Η κατεύθυνση της ροής υποδεικνύεται από τις σημάνσεις στο σώμα της βαλβίδας και στα συνοδευτικά έγγραφα. Οι συνδέσεις της σωλήνωσης θα πρέπει να είναι σύμφωνες με το μέγεθος που υποδεικνύεται στο σώμα, την ετικέτα και στο φυλλάδιο του προϊόντος. ΠΡΟΣΟΧΗ : • Ο περιορισμός των συνδέσεων μπορεί να οδηγήσει σε λανθασμένο χειρισμό ή κακή λειτουργία. • Για την προστασία του εξοπλισμού, τοποθετήστε μία κατάλληλη για τη συγκεκριμένη εργασία σήτα ή φίλτρο, στην πλευρά εισόδου και όσο το δυνατόν πιο κοντά στο προϊόν. • Εάν χρησιμοποιήσετε ταινία, αλοιφή, σπρέι ή παρόμοιο λιπαντικό κατά τη σύσφιξη, αποφύγετε την είσοδο σωματιδίων στο σύστημα. • Χρησιμοποιείτε τα κατάλληλα εργαλεία και τοποθετήστε τα κλειδιά όσο το δυνατόν πιο κοντά στο σημείο σύνδεσης. • Για να αποφύγετε τυχόν βλάβες στον εξοπλισμό, ΜΗ ΣΦΙΞΕΤΕ ΠΟΛΥ τις συνδέσεις των σωλήνων. Τηρήστε τη μέγιστη ροπή σύσφιγξης από 5 έως 7 Nm. • Μη χρησιμοποιείτε τη βαλβίδα ή την ηλεκτρομαγνητική κεφαλή ως μοχλό. • Οι συνδέσεις σωλήνων δεν πρέπει να ασκούν δύναμη, ροπή ή πίεση στο προϊόν. ΗΛΕΚΤΡΙΚΗ ΣΥΝΔΕΣΗ Όλες οι ηλεκτρικές συνδέσεις πρέπει να γίνονται μόνο από εξειδικευμένο και εκπαιδευμένο προσωπικό και θα πρέπει να ακολουθούν τους τοπικούς κανονισμούς και πρότυπα. ΠΡΟΣΟΧΗ: • Πριν από οποιαδήποτε επέμβαση, διακόψτε την ηλεκτρική τροφοδοσία για να απενεργοποιήσετε τα εξαρτήματα. • Όλοι οι ακροδέκτες των βιδών πρέπει να έχουν σφιχτεί σωστά προτού τεθούν σε λειτουργία. • Ανάλογα με την τάση, τα ηλεκτρικά εξαρτήματα πρέπει να έχουν γειωθεί σύμφωνα με τα τοπικά πρότυπα και κανονισμούς. • Για να διασφαλίσετε συνέχεια γης του πηνίου, βεβαιωθείτε ότι το πηνίο έχει τοποθετηθεί σωστά κατά την συναρμολόγηση/ αποσυναρμολόγηση. 1). Ο εξοπλισμός έχει συνδεθεί ηλεκτρικά ως εξής: • Αποσπώμενος συνδετήρας ISO 4400 / EN 175301-803, μορφή A (Με μία σωστή σύνδεση και όταν ο (χορηγούμενος ΑΠΟΣΥΝΑΡΜΟΛΟΓΗΣΗ Αποσυναρμολογήστε τα εξαρτήματα στη σειρά που υποδεικνύουν οι εικόνες στις Οδηγίες Εγκατάστασης και Συντήρησης. 1 - Αφαιρέστε το έλασμα συγκράτησης (1), διατηρήστε την καθοδική πίεση, και το πηνίο (2) (βλ. κωδικοί πηνίο σε επόμενες σελίδες). 2 - Αφαιρέστε το πλακέ ελατήριο (10). 3 - Ξεβιδώστε τη μονάδα πυρήνα-αγωγού (3) και διαχωρίστε την από το σώμα (4). 4 - Ξεβιδώστε τη μονάδα πυρήνα/ελατήριο (5)(6) και το στεγανοποιητικό παρέμβυσμα (8). 5 - Καθαρίστε ή αντικαταστήστε όλα τα εξαρτήματα. ΕΠΑΝΑΣΥΝΑΡΜΟΛΟΓΗΣΗ Επανασυναρμολογήστε όλα τα εξαρτήματα στην αντίθετη σειρά που ακολουθήθηκε κατά τη στη συναρμολόγηση. Βεβαιωθείτε ότι το ελατήριο συγκράτησης είναι σωστά τοποθετημένο στο πηνίο (βλέπε σχεδιάγραμμα). Ο αγωγός εκπομπής αερίων πρέπει είναι συνδεδεμένος προκειμένου να αποφευχθεί η μόλυνση των εσωτερικών τμημάτων της ηλεκτρομαγνητικής βαλβίδας. ΣΗΜΕΙΩΣΗ: 1 - Αλείψτε με γράσο το στεγανοποιητικό παρέμβυσμα (8) και καλύψτε ελαφρά την εξωτερική περιφέρεια του πυρήνα με λιπαντικό που είναι σύμφωνο με τις κατηγορίες HL και FC του προτύπου AFNOR ISO TR 3498. 2 - Βεβαιωθείτε ότι η μονάδα πυρήνα-αγωγού έχει σφιχτεί επαρκώς με ροπή (a). 3 - Αντικαταστήστε το πλακέ ελατήριο, το πηνίο και το έλασμα συγκράτησης. Συνδέστε το συγκρότημα του συνδέσμου. 4 - Μετά την επανασυναρμολόγηση, θέστε σε λειτουργία πολλές φορές την ηλεκτρομαγνητική βαλβίδα για να βεβαιωθείτε ότι οι βαλβίδες ανοίγουν και κλείνουν καλά. 5 - Επανασυναρμολογήστε τις συνδέσεις σωλήνωσης και σφίξτε με Μέγιστη ροπή από 5 έως 7 Nm. 13 524685-001 Návod na instalaci a údržbu Solenoidové ventily NC-NO-U 3/2, přímo ovládané. mosazné nebo nerezové ocelové tělo, 1/8 - 1/4, série 314 2 2 3 1 3 1 3 2 CZ UVEDENÍ DO PROVOZU Před natlakovaním okruhu vykonejte elektrický test. V případě solenoid ventilů několikrát uveďte vinutí pod napětí a všimněte si kovové kliknutí označující provoz solenoidu. POPIS Série 314, 3/2 NC-NO-U: • Solenoidové ventily se šroubeními velikosti 1/8-1/4. Tělo z mosaze nebo z nerezové ocele. ATEX verze: Cívky: Každé z 238 základních čísel je schváleno normou UL a CSA a označeno odpovídajícími štítky UL a CSA. Viz “Speciální podmínky pro bezpečné použití”. FUNKCE Většina solenoid ventilů je vybavených vinutím pro nepřetržitý provoz. Aby se zabránilo riziku zranění osob, nedotýkejte se solenoid operátora, který může při běžných provozních podmínkách dosahovat vysokých teplot. Když je solenoid ventil lehce přístupný, musí montér zhotovit ochranu proti náhodnému kontaktu. Naše elektromagnetické a řídící ventily jsou vyrobeny tak, aby fungovaly se zařízeními vyhovujícími standardu EN 61131-2. SPECIÁLNÍ PODMÍNKY PRO BEZPEČNÉ POUŽITÍ Pro solenoid operátory ve verzi ATEX musí být návod na použití uveden ve specifickém Návodě na Údržbu dodaném s výrobkem striktně dodržován. Solenoidové ventily se šroubeními: Standard verze anebo verze vybavené solenoid operátory, Ex d, Ex e mb, Ex mb, Ex tc (SG), pro použití ve výbušných atmosférách ve verzi ATEX-IECEx. EMISE HLUKU Emise hluku závisí od aplikace, kapalině a typu použitého zařízení. Přesné určení hladiny hluku může být vykonáno jen uživatelem, který má ventil už nainstalovaný v jeho systému. MONTÁŽ Komponenty ASCO jsou určené pro použití jen v souladu s technickými charakteristiky specifikovanými na továrním štítku anebo v dokumentaci. Aby se zabránilo poškození zařízení, ujistěte se, že jste zabránili kapalině dostat se do tuhnoucí fáze při nízkých teplotách a že se pohybujete v rámci maximálního a minimálního teplotního intervalu. Modifikace na zařízení můžou být vykonány jen po konzultaci s výrobcem anebo jeho zástupcem. Před instalací snižte tlak v potrubním systému a vnitřně ho vyčistěte. Solenoidové ventily můžou být namontovány v jakékoliv pozici bez ovlivnění činnosti. Směr toku je uvedený značeními na těle ventilu a v dokumentaci. Potrubní přípojky musí být v souladu s velikostí uváděnou na těle, štítku anebo v prospektu výrobku. UPOZORNĚNÍ : • Snížení připojení může způsobit nesprávný provoz a fungování. • Pro ochranu vybavení nainstalujte čistič anebo filtr vhodný pro provoz na straně přítoku, co nejblíže k výrobku. • V případě použití pásky, lepidla, spreje anebo obdobního maziva při upínání, zabraňte částicím vniknout do systému. • Použijte vhodné nástroje a umístíte klíče co nejblíže k bodu připojení. • Aby se zabránilo poškození zařízení, NEPŘETAHUJTE potrubní přípojky. Dodržujte maximální utahovací moment od 5 do 7 Nm. • Nepoužívejte ventil anebo solenoid operátora jako páku. • Potrubní přípojky by neměli na výrobek vyvíjet žádnou silu, točivý moment ani pnutí ÚDRŽBA Údržba výrobků ASCO závisí od provozních podmínek. Doporučuje se pravidelné čištění, časování kterého bude závislé od použitých kapalin a od provozních podmínek. Během servisu musí být komponenty zkontrolované pro nadměrné opotřebení. Kompletní sada vnitřních součástí je k dispozici jako náhradní díly anebo jako sada pro přestavbu. Když nastane problém během instalace/údržby anebo v případě pochybností prosím kontaktujte ASCO anebo autorizovaného zástupce. DEMONTÁŽ Demontujte součástky v pořadí označeném na pohledech v tomto Návode na instalaci a údržbu 1 - Odstraňte příchytku (1), stále tlačte dolů, a vinutí (2) (viz kódy vinutí na následujících stranách). 2 - Odstraňte pružnou podložku (10). 3 - Odšroubujte jaderní potrubní jednotku (3) a oddělte jí od těla (4). 4 - Odstraňte jednotku jádro/pružina (5)(6) a těsnění (8). 5 - Vyčistěte anebo vyměňte všechny součástky. SMONTOVÁNÍ Smontujte součástky v opačném pořadí demontáže. Ujistěte se, že příchytka je ve správné pozici na vinutí (viz. nákres). Výfuk musí být zapojen, aby se tak předešlo znečištění vnitřku solenoid ventilu. POZNÁMKA: 1 - Namažte těsnění (8) a jemně natřete vnější obvod jádra mazivem odpovídajícím standardu AFNOR ISO TR 3498 kategorie HL a FC. 2 - Ujistěte se, že jednotka jaderního potrubí je řádně utažená na utahovací moment (A). 3 - Nainstalujte pružnou podložku, vinutí a příchytku. Připojte sestavu konektoru. 4 - Po smontování uveďte solenoid ventil do provozu, aby jste se tak ujistili, že se ventily řádně otevírají a zavírají. 5 - Smontujte potrubní přípojky a utáhněte na maximální utahovací moment od 5 do 7 Nm. ELECTRICKÉ PŘIPOJENÍ Všechny elektrické připojení musí být vykonané jen vyškoleným a kvalifikovaným personálem a musí být v souladu s místními nařízeními a standardy. UPOZORNĚNÍ : • Před jakýmkoliv zásahem vypněte elektrický proud pro uvedení komponentů mimo napětí. • Všechny šroubové svorky musí být před uvedením do provozu řádně utáhnuté předtím. • V závislosti od elektrického napětí musí být elektrické komponenty uzemněné v souladu s místními standardy a nařízeními. • Pro zajištění kontinuity uzemnění vinutí se ujistěte, že je v průběhu montáže/demontáže správně umístěné (č. 1). Zařízení je elektricky zapojeno tímto způsobem: • Odpojitelný konektor na ISO 4400 / EN 175301-803, form A (Při správném připojení a s použitím (dodaného nebo zvoleného) konektoru, který je určený pro IP65 nebo IP67, bude mít elektromagnetický ventil ochranu IP65 nebo IP67). 14 524685-001 Instrukcje dotyczące instalacji i konserwacji Zawory elektromagnetyczne NC-NO-U 3/2, do bezpośredniego użycia korpus mosiężny lub ze stali nierdzewnej, 1/8 - 1/4 seria 314 2 2 3 1 3 1 3 2 PL IP65 lub IP67, zawór elektromagnetyczny będzie miał także klasę ochrony IP65 lub IP67). OPIS Seria 314, 3/2 (2-drogowe) NC-NO-U : • Zawory elektromagnetyczne z przyłączem gwintowanym 1/8-1/4. Korpus mosiężny lub ze stali nierdzewnej. Cewki: Wszystkie 238 numerów podstawowych jest zatwierdzonych przez UL i CSA oraz oznaczonych odpowiednim logo UL i CSA. Wersje ATEX: Patrz „Specjalne warunki bezpiecznego używania” URUCHOMIENIE Przed zahermetyzowaniem obwodu należy przeprowadzić test elektryczny. W przypadku zaworów elektromagnetycznych należy zasilić cewkę parokrotnie aż do usłyszenia metalicznego dźwięku wskazującego na działanie solenoidu. DZIAŁANIE Większość zaworów elektromagnetycznych jest wyposażona w cewki przeznaczone do pracy ciągłej. Aby uniknąć niebezpieczeństwa obrażeń, nie należy dotykać solenoidu, który w normalnych warunkach eksploatacji może się mocno nagrzewać. Jeśli zawór elektromagnetyczny jest łatwo dostępny, monter powinien zabezpieczyć się przed przypadkowym kontaktem. Nasze zawory elektromagnetyczne i zawory pilotowe są przystosowane do współpracy z urządzeniami zgodnymi z normą EN 61131-2. SPECJALNE WARUNKI BEZPIECZNEGO UŻYWANIA Do sterowania solenoidu zgodnie z dyrektywą ATEX, trzeba ściśle przestrzegać instrukcji użytkowania zawartych w szczegółowych Instrukcjach dotyczących Instalacji dostarczonych wraz z tym produktem. Zawory elektromagnetyczne z przyłączem gwintowym: Wersje o klasie ochrony lub wersje ze sterowaniem solenoidu, Ex d, Ex e mb, Ex mb, Ex tc (SG), do użytku w środowiskach zagrożonych wybuchem zgodnie z dyrektywą ATEX-IECEx (dotyczącą potencjalnych wydzielin wybuchowych). WYDAWANIE DŹWIĘKU Wydawanie dźwięku zależy od zastosowania, płynu i rodzaju użytego urządzenia. Dokładne określenie poziomu głośności może być przeprowadzone jedynie przez użytkownika już po zainstalowaniu zaworu w systemie. MONTAŻ Podzespoły ASCO są przeznaczone do użytku jedynie zgodnie z charakterystyką techniczną podaną na tabliczce znamionowej lub w dokumentacji. Aby uniknąć uszkodzenia produktu należy nie dopuścić do zestalenia się płynu w niskich temperaturach i nie dopuścić do przekroczenia maksymalnej ani minimalnej temperatury działania. Modyfikacji urządzenia można dokonać jedynie po konsultacji z producentem lub jego przedstawicielem. Przed instalacją należy rozhermetyzować instalację rurową i wyczyścić od środka. Zawory elektromagnetyczne mogą być zamontowane w dowolnym ustawieniu bez wpływu na ich działanie. Kierunek przepływu wskazuje oznakowanie na korpusie zaworu i opis w dokumentacji. Przyłącza rur muszą być zgodne z wielkością podaną na korpusie zaworu, tabliczce znamionowej lub w ulotce produktu. UWAGA: • Skracanie przyłączy może spowodować nieprawidłowe działanie lub awarię techniczną. • W celu ochrony produktu, należy w części wlotowej tak blisko produktu jak to możliwe, zamontować sitko lub filtr odpowiedni do przeznaczenia produktu. • Jeśli taśma, pasta do gwintów, spray lub podobna substancja nawilżająca jest używana podczas dokręcania, należy uniknąć dostania się ich drobinek do systemu. • Należy używać właściwych narzędzi i umieścić klucze tak blisko miejsca łączenia jak to możliwe. • Aby uniknąć uszkodzenia produktu, NIE WOLNO PRZEKRĘCAĆ przyłączy rur. Maksymalny moment obrotowy dokręcenia powinien wynieść 5 do 7 Nm. • Nie należy używać zaworu ani sterowania solenoidu jako dźwigni. • Przyłącza rur nie powinny oddziaływać jakąkolwiek siłą, przykładać momentu obrotowego ani naciskać na produkt. KONSERWACJA Konserwacja produktów ASCO zależy od warunków eksploatacji. Zaleca się okresowe czyszczenie, którego częstotliwość jest uzależniona od rodzaju stosowanego płynu i warunków eksploatacji. Podczas serwisowania należy sprawdzić, czy podzespoły nie uległy nadmiernemu zużyciu. Kompletny zestaw wewnętrznych części jest dostępny jako zestaw części zamiennych albo zestaw naprawczy. W razie wystąpienia problemu w trakcie instalacji/konserwacji lub w razie wątpliwości, należy skontaktować się z firmą ASCO lub jej autoryzowanym przedstawicielem. DEMONTAŻ Należy zdemontować części w kolejności wskazanej na schematach zamieszczonych w niniejszej Instrukcji dotyczącej instalacji i konserwacji. 1 - Wyjąć zacisk mocujący (1), utrzymując ciśnienie do dołu, oraz cewkę (2) (patrz kody cewek na następnych stronach). 2 - Wyjąć płaską sprężynę (10). 3 - Odkręć tuleję trzpienia ruchomego (3) i oddziel ją od korpusu (4) 4 - Usuń rdzeń ruchomy/sprężynę zaworową (5)(6) i uszczelkę (8) 5 - Wyczyść lub wymień wszystkie części. PONOWNY MONTAŻ Ponownie zamontuj części w kolejności odwrotnej niż podczas demontażu. Należy upewnić się, że zacisk jest właściwie umieszczony na cewce (patrz rysunek). Wylot musi być podłączony, aby uniknąć zanieczyszczenia wewnętrznej części zaworu elektromagnetycznego. UWAGA: 1 - Nasmaruj uszczelkę (8) i lekko pokryj zewnętrzny obwód rdzenia ruchomego substancją nawilżającą zgodną z normą AFNOR ISO TR 3498 w kategoriach HL i FC. 2 - Należy upewnić się, że tuleja trzpienia ruchomego jest odpowiednio dokręcona przy momencie obrotowym (A). 3 - Wymienić płaską sprężynę, cewkę i zacisk mocujący. Podłączyć zespół złącza. 4 - Po ponownym montażu, sprawdź kilkakrotnie zawór elektromagnetyczny, aby upewnić się, że zawory otwierają się i zamykają prawidłowo. 5 - Ponownie podłączyć instalację rurową i dokręcić przy momencie obrotowym od 5 do 7 Nm. ŁĄCZA ELEKTRYCZNE Wszystkie instalacje elektryczne muszą być wykonywane wyłącznie przez wyszkolonych i wykwalifikowanych pracowników i spełniać wymogi miejscowych przepisów i norm. UWAGA: • Przed jakąkolwiek ingerencją, należy odłączyć dopływ prądu elektrycznego do wszystkich podzespołów. • Wszystkie śruby muszą być prawidłowo dokręcone przez przywróceniem produktu do pracy. • W zależności od napięcia, podzespoły elektryczne muszą być uziemione zgodnie z miejscowymi normami i przepisami. • Aby zapewnić ciągłość uziemienia cewki, należy upewnić się, że została ona właściwie umieszczona podczas montażu/ demontażu (nr 1). Podłączenie elektryczne produktu jest następujące: • Wymienne przyłącze do ISO 4400 / EN 175301-803, form A (Pod warunkiem poprawnego podłączenia oraz gdy (dostarczone lub wybrane) zastosowane złącze ma klasę ochrony 15 524685-001 Telepítési és karbantartási utasítások 3/2-es NC-NO-U mágnesszelepek, közvetlen működtetésű sárgaréz vagy rozsdamentes acél test, 1/8 - 1/4, 263/263-os sorozat 2 2 3 1 3 1 3 2 HU ÜZEMBE HELYEZÉS Mielőtt nyomás alá helyezi az áramkört, végezzen elektromos tesztelést. Mágnesszelepek esetén kapcsolja be néhányszor a tekercset, és figyelje meg a fémes kattanást, amely az elektromágnes működését jelzi. LEÍRÁS 263/263-os sorozat, 3/2 NC-NO-U: • Mágnesszelep 1/8-1/4 menetes csatlakozókkal. Sárgaréz vagy rozsdamentes acél test. Tekercsek: Mind a 238 alapszám UL és CSA által jóváhagyott, és a megfelelő UL és CSA logókkal látták el őket. ATEX változatok: Lásd “A biztonságos használat speciális feltételei” című részt. MŰKÖDTETÉS A legtöbb mágnesszelep folyamatos működésre tervezett tekerccsel van ellátva. A személyi sérülések elkerülése érdekében ne érintse meg szolenoidot, mert az normál üzemi körülmények közt is felforrósodhat. Ha a mágnesszelep könnyen megközelíthető helyen van, a telepítőnek védelmet kell biztosítania a véletlen érintéssel szemben. Szolenoid szelepeink és vezérlőszelepeink úgy vannak megtervezve, hogy az EN 61131-2 szabványnak megfelelő termékekkel együttműködjenek. A BIZTONSÁGOS HASZNÁLAT SPECIÁLIS FELTÉTELEI Az ATEX szolenoidok esetében szigorúan követni kell a termékhez adott speciális telepítési utasításokat. Mágnesszelepek menetes csatlakozókkal: Szabvány védettségi fokozatú változatok vagy működtető mágnestekerccsel felszerelt változatok, Ex d, Ex e mb, Ex mb, Ex tc (SG), az ATEX-IECEx szerinti robbanásveszélyes légterekben való használathoz. HANGKIBOCSÁTÁS A hangkibocsátás az alkalmazástól, a folyadéktól és a használt berendezés típusától függ. A hangerő szintjének pontos meghatározását csak a felhasználó végezheti el a szelep rendszerbe való beszerelése után. SZERELÉS Az ASCO alkatrészek csak az adattáblán vagy a dokumentációban meghatározott műszaki jellemzők tartományában használhatók. A berendezés sérülésének elkerülése érdekében akadályozza meg a folyadék alacsony hőfokon történő megszilárdulását, és tartsa a maximális és minimális hőmérsékleti határértékek között. A berendezést csak a gyártóval vagy annak képviselőjével való konzultáció után módosítható. A telepítés előtt nyomásmentesítse a csőrendszert és végezzen belső tisztítást. A mágnesszelepek bármilyen helyzetben felszerelhetők, a helyzet nem befolyásolja a működést. Az áramlás irányát a szeleptesten és a dokumentációban látható jelzések mutatják. A csőcsatlakozóknak meg kell felelniük a testen vagy a címkén jelzett, illetve a termékismertető füzetben megadott méreteknek. VIGYÁZAT: • A csatlakozó méretének csökkentése helytelen működést vagy meghibásodást okozhat. • A berendezés védelmének érdekében telepítsen egy a szervizeléshez alkalmas szitát vagy szűrőt a bemeneti oldalra, minél közelebb a termékhez. • Ha a rögzítésnél szalagot, kenőcsöt, sprayt vagy hasonló kenőanyagot használ, ügyeljen rá, hogy annak részecskéi ne kerüljenek be a rendszerbe. • Használjon megfelelő eszközöket, és a csavarkulcsokat a lehető legközelebb helyezze a csatlakozási ponthoz. • A berendezés sérülésének elkerülése érdekében NE HÚZZA MEG TÚL ERŐSEN a csőcsatlakozókat. A meghúzó nyomaték nem haladhatja meg az 5-7 Nm-t. • Ne használja a szelepet vagy a mágnestekercset emelőkarként. • A csőcsatlakozók nem gyakorolhatnak erőt, nyomatékot vagy terhelést a termékre. KARBANTARTÁS Az ASCO termékek karbantartása az üzemi körülményektől függ. Javasolt rendszeres tisztítást végezni, melynek gyakorisága a használt folyadéktól és az üzemi körülményektől függ. A szervizelés során ellenőrizze az alkatrészek kopásának mértékét. A belső alkatrészek teljes készlete beszerezhető pótalkatrész- vagy átszerelő készletben. Ha a szerelés/karbantartás közben probléma adódik, vagy kétségei merülnek fel, lépjen kapcsolatba az ASCO céggel vagy annak hivatalos képviselőivel. SZÉTSZERELÉS Az alkatrészeket a telepítési és karbantartási utasításokban látható ábráknak megfelelő sorrendben kell szétszerelni. 1 - Folyamatosan lefelé nyomva távolítsa el a tartókapcsot (1) és a tekercset (2) (a tekercskódok a következő oldalakon). 2 - Távolítsa el a lapos rugót (10). 3 - Csavarozza ki a központi csőegységet (3) és válassza el a testtől (4). 4 - Távolítsa el a központi/rugó egységet (5)(6) és a tömítést (8). 5 - Tisztítson meg vagy cseréljen ki minden alkatrészt. ISMÉTELT ÖSSZESZERELÉS Az alkatrészeket a szétszereléssel ellentétes sorrendben kell összeszerelni. Ügyeljen rá, hogy a tartókapocs megfelelő helyzetben kerüljön a tekercsre (lásd az ábrát). A kiömlőnyílást úgy kell csatlakoztatni, hogy az elektromágnes tekercsének belseje ne szennyeződhessen. MEGJEGYZÉS: 1 - Zsírozza meg a tömítést (8), a mag külső peremét pedig enyhén kenje meg az AFNOR ISO TR 3498 szabvány HL és FC kategóriáinak megfelelő kenőanyaggal. 2 - Ügyeljen rá, hogy a központi csőegység meghúzása a megfelelő meghúzó nyomatékkal (A). 3 - Helyezze vissza a lapos rugót, a tekercset és a tartókapcsot. Szerelje vissza a csatlakozószerelvényt. 4 - Az ismételt összeszerelés után kapcsolja be néhányszor a mágnesszelepet vagy, és ellenőrizze, hogy a szelepek megfelelően nyílnak és záródnak-e. 5 - Szerelje vissza a csőcsatlakozókat, és húzza meg azokat legfeljebb 5-7 Nm meghúzó nyomatékkal. ELEKTROMOS CSATLAKOZTATÁS Minden elektromos csatlakoztatást csak szakképzett személyzet végezhet, a helyi rendeleteknek és szabványoknak megfelelően. VIGYÁZAT: • Bármilyen beavatkozás előtt kapcsolja le a feszültséget az alkatrészekről. • A használatba helyezés előtt minden szorítócsavart jól meg kell húzni. • Az elektromos alkatrészeket a feszültségtől függően megfelelően földelni kell, a helyi szabványok és rendeletek szerint. • A tekercs folytonos földelése érdekében azt megfelelően helyezze el az összeszereléskor/szétszereléskor (1. ábra). A berendezés elektromos csatlakoztatása: • Levehető EN 175301-803, form A (Megfelelő csatlakoztatás és a (mellékelt vagy kiválasztott) IP65 vagy IP67 besorolású csatlakozó használata esetén a szolenoid szelep IP65 vagy IP 67 védelmi besorolással fog rendelkezni). 16 524685-001 Общие указания по установке и обслуживанию Электромагнитные 3/2 NC-NO-U с прямым приводом, медный или стальной корпус, серия 2314 1/8 - 1/4 2 2 3 1 3 1 3 2 RU ВВОД В ЭКСПЛУАТАЦИЮ Прежде чем создавать давление в контуре, проверьте электросистему. В случае электромагнитных клапанов несколько раз включите питание катушки и проверьте наличие металлического щелчка, свидетельствующего о срабатывании соленоида. ОПИСАНИЕ Серия 314, 3/2 NC-NO-U: • Электромагнитные клапаны с резьбовыми соединениями 1/8-1/4. Медный корпус или корпус из нержавеющей стали. Катушки: Все 238 основных чисел утверждены UL & CSA и помечены соответствующим логотипом UL & CSA. Исполнения ATEX: См. “Особые условия безопасного использования”. РАБОТА Большинство электромагнитных клапанов оснащены катушками, обеспечивающими длительный срок эксплуатации. Чтобы избежать травм, не касайтесь электромагнитного исполнительного устройства, которое может сильно нагреваться даже при нормальных условиях работы. Если электромагнитный клапан легкодоступен, специалист по установке должен обеспечить защиту от случайного контакта. Наши электромагнитные и управляющие клапаны предназначены для эксплуатации с устройствами, соответствующими требованиям стандарта EN 61131-2. ОСОБЫЕ УСЛОВИЯ БЕЗОПАСНОГО ИСПОЛЬЗОВАНИЯ Для электромагнитных исполнительных устройств стандарта ATEX необходимо строго соблюдать указания по использованию, приведенные в соответствующей инструкции по установке, прилагаемой к изделию. Электромагнитные клапаны с резьбовыми соединениями: стандартные модели или модификации с электромагнитным исполнительным устройством для использования во взрывоопасных средах маркируются префиксом Ex d, Ex e mb, Ex mb, Ex tc (SG), согласно требованиям ATEX. ИЗЛУЧЕНИЕ ЗВУКА Излучение звука зависит от области применения, рабочей среды и типа используемого оборудования. Точно определить уровень шума может только пользователь после установки клапана в системе. СБОРКА Компоненты ASCO предназначены для использования только с соблюдением технических характеристик, указанных на паспортной табличке или в документации. Чтобы предотвратить повреждение оборудования, не допускайте замерзания жидкостей при низких температурах и соблюдайте максимальные и минимальные температурные ограничения. Модификация оборудования допускается только после консультаций с изготовителем или его представителем. Перед установкой сбросьте давление в трубопроводе и очистите его внутренние поверхности. Электромагнитные клапаны можно устанавливать в любом положении, это не влияет на их работоспособность. Направление потока указано метками на корпусе клапана и в документации. Трубные соединения должны быть выполнены в соответствии с размерами, указанными на корпусе, наклейке или в брошюре с описанием изделия. ОСТОРОЖНО: • Уменьшение длины соединения может стать причиной сбоев в работе или неисправности. • Для защиты оборудования установите подходящую сетку или фильтр на впуске как можно ближе к изделию. • Если при затяжке используется лента, паста, спрей или аналогичные смазки, не допускайте попадания их в систему. • Используйте подходящие инструменты и устанавливайте гаечные ключи как можно ближе к точке соединения. • Чтобы не допустить повреждения оборудования, НЕ ПЕРЕТЯГИВАЙТЕ трубные соединения. Не превышайте максимальный момент затяжки 5-7 Нм. • Не используйте клапан или электромагнитный привод в качестве рычага. • Изделие не должно подвергаться давлению, скручивающему усилию или натяжению со стороны трубных соединений. ТЕХНИЧЕСКОЕ ОБСЛУЖИВАНИЕ Обслуживание изделий ASCO зависит от условий эксплуатации. Рекомендуется проводить периодическую очистку, сроки которой зависят от используемых рабочих сред и условий эксплуатации. Во время обслуживания необходимо проверять компоненты на предмет чрезмерного износа. Полный набор компонентов доступен в виде запчастей или комплекта для восстановления изделия. В случае возникновения проблем при установке или обслуживании, либо при появлении каких-либо сомнений обратитесь в ASCO или к официальным представителям компании. РАЗБОРКА Разбирайте части в порядке, указанном на иллюстрациях в этой инструкции по установке и техническому обслуживанию. 1 - Снимите пружинную защелку (1), нажимая вниз, и катушку (2) (см. коды катушек на следующих страницах). 2 - Снимите плоскую пружину (10). 3 - Отвинтите блок внутренней трубки (3) и отсоедините его от корпуса (4). 4 - Снимите внутреннюю пружину (5)(6) и уплотнение (8). 5 - Очистите или замените все детали. СБОРКА Соберите детали в порядке, обратном разборке. Убедитесь, что пружинная защелка правильно установлена на катушке. (См. чертеж.). Для предотвращения загрязнения внутренней части электромагнитного клапана подсоедините выпуск. ПРИМЕЧАНИЕ: 1 - Смажьте уплотнение (8) и нанесите немного смазки стандарта AFNOR ISO TR 3498 (категории HL и FC) на внешнюю окружность сердцевины. 2 - Убедитесь, что блок внутренней трубки надежно затянут с усилием (a). 3 - Замените плоскую пружину, катушку и пружинную защелку. Подсоедините разъем в сборе. 4 - После сборки несколько раз включите электромагнитный клапан или коллектор, чтобы убедиться в его работоспособности. 5 - Соберите трубные соединения и затяните усилием не более 5-7 Нм. ЭЛЕКТРОПОДКЛЮЧЕНИЯ Электроподключение должен выполнять только квалифицированный специалист. Соединение должно отвечать требованиям местных нормативных актов и стандартов. ОСТОРОЖНО: • Перед выполнением каких-либо работ на изделии выключите питание, чтобы обесточить компоненты устройства. • Перед вводом в эксплуатацию все зажимные контакты необходимо надежно затянуть. • В зависимости от напряжения электрические компоненты следует заземлить в соответствии с местными стандартами и нормативами. • Чтобы обеспечить надлежащее заземление катушки, при сборке/разборке ее следует правильно располагать. Электрические соединения оборудования следующие: • Съемный соединитель стандарта ISO 4400 / EN 175301-803, форма A (при надлежащем заземлении и если используется соединитель (из комплекта поставки или выбранный) класса IP65 или IP67, защита электромагнитного клапана будет соответствовать классу IP65 или IP67). 17 524685-001 ОРНАТУ ЖƏНЕ ТЕХНИКАЛЫҚ ҚЫЗМЕТ КӨРСЕТУ НҰСҚАУЛЫҚТАРЫ Тікелей басқарылатын, жезден немесе тот баспайтын болаттан жасалған, 314 1/8 - 1/4 сериялы 3/2 NC-NO соленоид клапандары СИПАТТАМАСЫ 314, 3/2 сериялы, NC-NO: • Бұрандалы 1/8 дюйм-1/4 дюйм қосылымы бар соленоид клапандары. Мыс немесе тот баспайтын болаттан жасалған корпус. Катушкалар: Барлық 238 негізгі нөмірлері UL жəне CSA сертификаттарына сəйкес мақұлданған, UR (анықталған құрамдас) жəне CSA логотиптерімен белгіленген. ATEX нұсқалары: "Қауіпсіз пайдалану бойынша арнайы шарттарды" қараңыз. 2 2 3 1 3 1 3 2 POCHETTES DE RECHANGE GB PARTI DI RICAMBIO ES RESERVEDELSPAKKE SE KIT DE PEÇAS DE SOBRESSELENTES DK SADA NÁHRADNÍCH DÍLU CZ ZESTAW CZĘŚCI ZAMIENNYCH ҚОСАЛҚЫ БӨЛШЕКТЕР ЖИНАҒЫ КОМПЛЕКТ ЗАПЧАСТЕЙ RU SPARE PARTS KIT BOLSAS DE RECAMBIO RESERVDELSSATS RESERVEDELE KIT KZ ПАЙДАЛАНУҒА БЕРУ Тізбекті қысымдаудан бұрын электрлік сынақ жүргізіңіз. Соленоид клапандары бар болған жағдайда катушканы қуат көзіне бірнеше рет қосыңыз жəне соленоид клапан жұмысын білдіретін металл ілмекке назар аударыңыз. ФУНКЦИЯСЫ Көптеген соленоид клапандары ұзақ қызмет ету үшін катушкалармен жабдықталған. Жеке жарақат алу мүмкіндігіне жол бермеу үшін, қалыпты жұмыс шарттарында қызуы мүмкін соленоидке тиіспеңіз. Соленоидты клапанға қол жеткізу оңай болса, орнатушы кездейсоқ тиіп кетуге қарсы қорғаныспен қамтамасыз етуі қажет. Соленоид клапандары мен басқарушы клапандар EN 61131-2 стандартына сай келетін құрылғылармен жұмыс істеуге арналған. ҚАУІПСІЗ ПАЙДАЛАНУ ЖӨНІНДЕГІ АРНАЙЫ ШАРТТАР ATEX директивасына қатысты соленоид операторлары үшін, өніммен бірге берілген арнайы Орнату нұсқауларындағы пайдалану нұсқаулары қатаң орындалуы қажет. Бұрандалы байланыстары бар соленоид клапандары: Стандартты нұсқалар немесе соленоид операторларымен жабдықталған нұсқалар, Ex d, Ex e mb, Ex mb, Ex tc (SG)Ex tc (SG) сериялары ATEX-IECE үшін жарылғыш атмосферада қолдануға арналған. ДЫБЫС ШЫҒАРУ Дыбыстың шығуы қолданбаға, сұйықтыққа жəне пайдаланылатын жабдықтар түріне байланысты. Дыбыс деңгейі клапан жүйеге пайдаланушы тарапынан орнатылған жағдайда ғана нақты анықталады. ЖИНАУ ASCO құрамдас бөлшектері тек идентификациялық тақтайшада көрсетілген техникалық сипаттамаға немесе құжаттамаға сай қолдануға арналған. Жабдықтың зақымдалуына жол бермеу үшін, төмен температурада сұйықтықты қатырып алмаңыз, максималды мен минималды температура шегінде сақтаңыз. Жабдықты тек өндіруші немесе оның өкілімен ақылдасқаннан кейін өзгертуге болады. Орнатпас бұрын, құбыр жүйесінің қысымын босатып, ішін тазалаңыз. Соленоид клапандарын жұмысқа кедергі келтірмей, кез келген жерде орнатуға болады. Ағынның бағыты клапан корпусы жəне құжаттамадағы белгілермен көрсетілген. Құбыр қосылымдары корпусында, затбелгісінде немесе өнім кітапшасында көрсетілген өлшемге сай болуы қажет. ЕСКЕРТУ: • Қосылымдарды қысқарту дұрыс жұмыс дұрыс болмауына немесе істен шығуға себеп болуы мүмкін. • Жабдықты қорғау үшін, кіріс жағында қамтылған, жарамды тор не сүзгіні өнімге барынша жақындатып орнатыңыз. • Егер бекемдеу кезінде таспа, паста, спрей не басқа да сол сияқты майлағыш пайдаланылса, бөлшектерінің жүйеге кіріп кетпеуін қадағалаңыз. • Тиісті құралдарды пайдаланып, гайка кілттерін қосылым нүктесіне барынша жақын орналастырыңыз. • Жабдықтың зақымдалмауы үшін құбыр қосылымдарын ШАМАДАН ТЫС БЕКІТПЕҢІЗ. Тартудың айналу моменті 5 7 Нм дейін болуын тексеріңіз. • Клапанды немесе соленоидты иінтірек ретінде пайдаланбаңыз. • Құбыр қосылымдары өнімге күш түсірмеуі, тартпауы жəне деформацияға ұшыратпауы керек. ҚАЙТА ЖИНАУ Бөліктерді бөлшектеудің кері ретімен қайта жинаңыз. Бекітуші қысқыштың өзекте дұрыс орналасқанына көз жеткізіңіз (суретті қараңыз). Соленоид клапанының іші ластанбауы үшін шығыс тетік жалғануы керек. ЕСКЕРТПЕ: 1 - Тығыздаманы (8) жағыңыз жəне өзектің сыртқы айналасын HL мен FC санаттарындағы AFNOR ISO TR 3498 стандартына сай маймен сəл майлап қойыңыз. 2 - Өзек түтігі элементі бұрау моментінде (а) дұрыс бекітілгеніне көз жеткізіңіз. 3 - Жалпақ серіппе, катушка жəне бекітуші қысқышты ауыстырыңыз. Коннектор жинағын жалғаңыз. 4 - Қайта жинағаннан кейін, клапанның тиісті түрде ашылып жабылуын қамтамасыз ету үшін соленоид клапанын бірнеше рет жұмыс істетіңіз. 5 - Құбыр қосылымдарын қайта жинаңыз жəне 5 - 7 Нм максималды бұрау моментінде бекітіңіз. ЭЛЕКТРЛІК ҚОСЫЛЫМ Барлық электрлік қосылымдар тек жаттықтырылған жəне білікті қызметкерлер тарапынан жасалуы қажет жəне жергілікті ережелер мен стандарттарға сай болуы керек. АБАЙЛАҢЫЗ: • Кез келген жұмысты орындамас бұрын, құрамдастарды өшіру үшін электр тогын өшіру қажет. • Пайдалануға берілудің алдында барлық электрлік бұрандалы қысқыштар тиісті түрде бекітілуі тиіс. • Кернеуге байланысты электрлік құрамдастар жергілікті стандарттар мен ережелерге сəйкес жерге тұйықталуы қажет. • Катушканың жерге үздіксіз тұйықталуын қамтамасыз ету үшін, жинау/бөлшектеу кезінде дұрыс орналасқанына көз жеткізіңіз (№ 1). Жабдықтың төменде көрсетілгендей электр байланысы бар: • ISO 4400 / EN 175301-803 стандартына сəйкес алмалы-салмалы жалғағыш, А формасы (тиісті байланыста жəне қолданылған жалғағыш (жабдықталған немесе таңдап алынған) IP65- немесе IP67-номиналды болғанда, соленоид клапанында IP65 немесе IP67 қорғанысы болады). 18 524685-001 DE NL FI GR HU - 314 (1/8) 1 1 UL 1 2 2 2 F items N.m Inch.pounds a 20±3 175±25 3 3 3 3b ТЕХНИКАЛЫҚ ҚЫЗМЕТ КӨРСЕТУ ASCO өнімдеріне техникалық қызмет көрсету процедурасы қызмет көрсету шарттарына байланысты. Жиі тазалап тұрған дұрыс, тазалау мерзімі қолданылатын сұйықтықтар мен қызмет көрсету шарттарына тəуелді. Қызмет көрсету барысында құрамдастардың шамадан тыс тозуы тексерілуі тиіс. Ішкі бөлшектердің толық жиынтығы қосалқы бөлшектер немесе жөндеу жинағы ретінде қолжетімді. Егер орнату/ техникалық қызмет көрсету кезінде ақаулық туындаса немесе күмəндансаңыз, ASCO компаниясына немесе оның заңды өкілдеріне хабарласыңыз. БӨЛШЕКТЕУ Бөлшектерді осы Орнату жəне техникалық қызмет көрсету нұсқаулығындағы суреттерде көрсетілген ретпен бөлшектеңіз. 1 - қысымды төмендетіп, бекітуші қысқышты (1) жəне катушканы (2) алып тастаңыз (келесі беттерден катушкалар кодтар қараңыз). 2 - Жалпақ серіппені (10) алыңыз. 2 - Өзек түтігі элементін (3) бұрап шығарыңыз жəне оны корпустан (4) ажыратыңыз. 3 - Өзек/серіппе элементін (5)(6) жəне тығыздамасын (8) алып тастаңыз. 4 - Барлық бөліктерді тазалаңыз немесе ауыстырыңыз. ERSATZTEILPACKUNG FR VERVANGINGSSET IT VARAOSASARJA NO PT ÊÉÔ ÁÍÔÁËËÁÊÔÉÊÙÍ PL PÓTALKATRÉSZ KÉSZLET KZ 5 6 10 8 4 1 1 2 AC (~) NBR G314K031 FPM 2 3/2 N0-NA 3/2 NC-NF a 1 2 & / FPM (oxygen) 3/2 U DC (=) EPDM NBR FPM / FPM (oxygen) EPDM M200070N00 M200070V00 M200070VN0 M200070E00 M200066N00 M200066V00 M200066VN0 M200066E00 G314K032/033 M200071N00 M200071V00 M200071VN0 M200071E00 M200067N00 M200067V00 M200067VN0 M200067E00 G314K037 M200072N00 M200072V00 M200072VN0 M200072E00 M200068N00 M200068V00 M200068VN0 M200068E00 G314K038/039 M200073N00 M200073V00 M200073VN0 M200073E00 M200069N00 M200069V00 M200069VN0 M200069E00 G314K040 M200079N00 M200079V00 M200079VN0 M200079E00 M200077N00 M200077V00 M200077VN0 M200077E00 G314K041 M200074N00 M200074V00 M200074VN0 M200074E00 M200074N00 M200074V00 M200074VN0 M200074E00 G314K042 M200076N00 M200076V00 M200076VN0 M200076E00 M200076N00 M200076V00 M200076VN0 M200076E00 G314K043 M200078N00 M200078V00 M200078VN0 M200078E00 M200075N00 M200075V00 M200075VN0 M200075E00 G314K044 M200079N00 M200079V00 M200079VN0 M200079E00 M200077N00 M200077V00 M200077VN0 M200077E00 G314K045 M200078N00 M200078V00 M200078VN0 M200078E00 M200075N00 M200075V00 M200075VN0 M200075E00 G314K049 M200080N00 M200080V00 M200080VN0 M200080E00 M200080N00 M200080V00 M200080VN0 M200080E00 G314K050/051 M200081N00 M200081V00 M200081VN0 M200081E00 M200081N00 M200081V00 M200081VN0 M200081E00 G314K055 M200080N00 M200080V00 M200080VN0 M200080E00 M200080N00 M200080V00 M200080VN0 M200080E00 G314K056/057 M200083N00 M200083V00 M200083VN0 M200083E00 M200083N00 M200083V00 M200083VN0 M200083E00 19 524685-001 POCHETTES DE RECHANGE GB PARTI DI RICAMBIO ES RESERVEDELSPAKKE SE KIT DE PEÇAS DE SOBRESSELENTES DK SADA NÁHRADNÍCH DÍLU CZ ZESTAW CZĘŚCI ZAMIENNYCH ҚОСАЛҚЫ БӨЛШЕКТЕР ЖИНАҒЫ КОМПЛЕКТ ЗАПЧАСТЕЙ RU SPARE PARTS KIT BOLSAS DE RECAMBIO RESERVDELSSATS RESERVEDELE KIT ERSATZTEILPACKUNG FR VERVANGINGSSET IT VARAOSASARJA NO PT ÊÉÔ ÁÍÔÁËËÁÊÔÉÊÙÍ PL PÓTALKATRÉSZ KÉSZLET KZ DE NL FI GR HU - POCHETTES DE RECHANGE GB PARTI DI RICAMBIO ES RESERVEDELSPAKKE SE KIT DE PEÇAS DE SOBRESSELENTES DK SADA NÁHRADNÍCH DÍLU CZ ZESTAW CZĘŚCI ZAMIENNYCH ҚОСАЛҚЫ БӨЛШЕКТЕР ЖИНАҒЫ КОМПЛЕКТ ЗАПЧАСТЕЙ RU 314 (1/4) 1 1 2 2 48 V = 48 V ~ 115 V ~ 230 V ~ - - - - 11,6 W 238513-006 238513-017 175±25 3 3 3 3 3 10,1 W 17,5= 4 2 1 = 3/2 N0-NA AC (~) FPM FPM (oxygen) DC (=) EPDM = 22 = Ø M5 - 7,5 mm 1/4 3/2 U & / Ø M5 - 6,5 mm 15 = 1/8 & 2 1 2 1 3/2 NC-NF E314K034 238213-006 238213-016 238213-033 238213-059 = 8 NBR - UL 5 6 10 a - 3 22 = Inch.pounds 20±3 MXX II -FT = N.m a & 24 V ~ 2 F items DE NL FI GR HU - 314 (1/4) 1 24 V = UL ERSATZTEILPACKUNG FR VERVANGINGSSET IT VARAOSASARJA NO PT ÊÉÔ ÁÍÔÁËËÁÊÔÉÊÙÍ PL PÓTALKATRÉSZ KÉSZLET KZ SPARE PARTS KIT BOLSAS DE RECAMBIO RESERVDELSSATS RESERVEDELE KIT NBR FPM / FPM (oxygen) M200094A00 Í R6 x 2 M200070N00 M200070V00 M200070VN0 M200070E00 M200066N00 M200066V00 M200066VN0 M200066E00 E314K035/036 M200071N00 M200071V00 M200071VN0 M200071E00 M200067N00 M200067V00 M200067VN0 M200067E00 E314K006 M200074N00 M200074V00 M200074VN0 M200074E00 M200074N00 M200074V00 M200074VN0 M200074E00 E314K007/008 M200078N00 M200078V00 M200078VN0 M200078E00 M200075N00 M200075V00 M200075VN0 M200075E00 36 22,4 15 6,4 x 4 F EPDM 52 AISI 1010 (1.1121) 6.8 10,5 5 18 43 37,7 35,45 9 6 17,3 21,8 20 1,5 36 6x 4 6,4 x 2 3,2 x 4 E314K052 M200080N00 M200080V00 M200080VN0 M200080E00 M200080N00 M200080V00 M200080VN0 M200080E00 E314K053/054 M200081N00 M200081V00 M200081VN0 M200076E00 M200081N00 M200081V00 M200081VN0 M200081E00 E314K068 M200072N00 M200072V00 M200072VN0 M200072E00 M200068N00 M200068V00 M200068VN0 M200068E00 E314K121/126 M200073N00 M200073V00 M200073VN0 M200073E00 M200069N00 M200069V00 M200069VN0 M200069E00 E314K123 M200076N00 M200076V00 M200076VN0 M200076E00 M200076N00 M200076V00 M200076VN0 M200076E00 E314K120/124 M200079N00 M200079V00 M200079VN0 M200079E00 M200077N00 M200077V00 M200077VN0 M200077E00 E314K069 M200082N00 M200082V00 M200082VN0 M200082E00 M200082N00 M200082V00 M200082VN0 M200082E00 E314K122/070 M200083N00 M200083V00 M200083VN0 M200083E00 M200083N00 M200083V00 M200083VN0 M200083E00 20 524685-001 M200095A00 AISI 304 (1.4301) 64 F Í 45 21,8 17,3 7,1 24,5 20,8 6 15 9,35 22,4 24 21 524685-001 POCHETTES DE RECHANGE GB PARTI DI RICAMBIO ES RESERVEDELSPAKKE SE KIT DE PEÇAS DE SOBRESSELENTES DK SADA NÁHRADNÍCH DÍLU CZ ZESTAW CZĘŚCI ZAMIENNYCH ҚОСАЛҚЫ БӨЛШЕКТЕР ЖИНАҒЫ КОМПЛЕКТ ЗАПЧАСТЕЙ RU SPARE PARTS KIT BOLSAS DE RECAMBIO RESERVDELSSATS RESERVEDELE KIT GB 1. Retaining clip 2. Coil 3a.(M6) 3b. (MXX) Description 4. Body 5. Core 6. Spring 8. O-ring 10 . Flat spring ES Descripcion 1. Clip de manteni- 4. Cuerpo miento 5. Núcleo 2. Bobina 6. Resorte 3a.(M6) 8. Junta tórica 10 . Resorte plano 3b. (MXX) NO 1. Festeklemme 2. Spolen 3a. (M6) 3b. (MXX) DK Beskrivelse 4. Kropp 5. Kjerne 6. Fjære 8. O-ring 10. Flat fjær Beskrivelse FR Description 1. Clip de maintien 4. Corps 2. Bobine 5. Noyau 3a.(M6) 6. Ressort 8. Joint torique 3b. (MXX) 10 . Ressort plat IT Descripzione 1. Clip di fissaggio 2. Bobina 3. Parte di ricambio 3a.(M6) 3b. (MXX) SE Beskrivning 1. Fästklämma 2. Spole 3a. (M6) 3b. (MXX) PT 4. Corpo 5. Nucleo 6. Molla 8. O-ring 10 . Molla piatta 4. Stomme 5. Kärna 6. Fjäder 8. O-ring 10. Platt fjäder Descrição 1. Fastholdelsesklips 2. Spole 3a. (M6) 3b. (MXX) 4. Hus 5. Kerne 6. Fjeder 8. O-ring 10. Flad fjeder 1. Braçadeira de fixação 2. Bobina 3a.(M6) 3b. (MXX)) 4. Corpo 5. Núcleo 6. Mola 8. Junta Tórica 10 . Mola plana CZ 1. Příchytka 2. Vinutí 3a. (M6) 3b. (MXX) Popis 4. Tělo 5. Jádro 6. Pružina 8. O-kroužek 10. Pružná podložka PL 1. Zacisk mocujący 2. Cewka 3a. (M6) 3b. (MXX) Opis 4. Korpus 5. Rdzeń 6. Sprężyna 8. O-ring 10. Płaska sprężyna RU 1. Пружинная защелка 2. Катушка 3a. (M6) 3b. (MXX) Описание 4. Корпус 5. Сердечник 6. Пружина 7. Plug 8. Уплотнительное кольцо 10. Плоская пружина ASCO SAS 53 rue de la Beauce, 28110 Luce - FRANCE 775 729 098 RCS Chartres ERSATZTEILPACKUNG FR VERVANGINGSSET IT VARAOSASARJA NO PT ÊÉÔ ÁÍÔÁËËÁÊÔÉÊÙÍ PL PÓTALKATRÉSZ KÉSZLET KZ DE DE NL FI GR HU - Bezeichnung 1. Halteclip 2. Magnet 3. Ersatzteil 3a.(M6) 3b. (MXX) NL 1. Borgclip 2. Spoel 3a.(M6) 3b. (MXX) FI 1. Kiinnityssinkilä 2. Käämi 3a. (M6) 3b. (MXX) 4. Gehäuse 5. Magnetanker 6. Feder 8. O-Ring 10 . Flachfeder Beschrijving 4. Huis 5. Plunjer 6. Veer 8. O-ring 10. Vlakke veer Kuvaus 4. Runko 5. Ydin 6. Jousi 8. O-rengas 10. Lattajousi Περιγραφή GR 1. Συνδετήρας συγκρά- 4. Body τησης 5. Πυρήνας 2. Πηνίο 6. Ελατήριο 3a.(M6) 8. Δακτύλιος Ο 3b. (MXX) 10 . Flat spring HU 1. Tartókapocs 2. Tekercs 3a. (M6) 3b. (MXX) Leírás 4. Test 5. Mag 6. Rugó 8. Tömítőgyűrű 10. Lapos rugó Сипаттамасы KZ 1. Бекітуші қысқыш 4. Корпус 2. Катушка 5. Өзек 3a.(M6) 6. Серіппе 8. О тəрізді сақина 3b. (MXX) 10. Жалпақ серіппе 22 524685-001 23 524685-001
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11

Asco Series 314 Solenoid Valve NC NO 1/4 1/8 Manual de usuario

Tipo
Manual de usuario