Welcome
Welcome to the Danby family. We are proud of our quality products and we believe in
dependable service. We suggest that you read this owner’s manual before plugging in your new
appliance as it contains important operation information, safety information, troubleshooting and
maintenance tips to ensure the reliability and longevity of your appliance.
Visit www.Danby.com to access self service tools, FAQs and much more. For additional assistance
call 1-800-263-2629.
Note the information below; you will need this information to obtain service under warranty.
You must provide the original purchase receipt to validate your warranty and receive service.
Model Number: _________________________________________________
Serial Number: _________________________________________________
Date of Purchase: _______________________________________________
Need Help?
Before you call for service, here are a few things you can do to help us serve you better.
Read this owner’s manual:
It contains instructions to help you use and maintain your appliance properly.
If you receive a damaged appliance:
Immediately contact the retailer or builder that sold you the appliance.
Save time and money:
Check the troubleshooting section at the end of this manual before calling. This section
will help you solve common problems that may occur.
1-800-26- Danby
(1-800-263-2629)
1
2
SAVE THESE INSTRUCTIONS!
CAUTION: RISK OF FIRE
Flammable refrigerant used. When maintaining
or disposing of the air conditioner, the refrigerant
must not be allowed to vent into the open air.
SAFETY REQUIREMENTS
DANGER: Risk of fi re or explosion. Flammable
refrigerant used. Do not damage the refrigerant
circuit.
Ensure that servicing is done by factory
authorized service personnel, to minimize
product damage or safety issues.
Consult repair manual or owner’s guide before
attempting to service this product. All safety
precautions must be followed.
Dispose of properly in accordance with federal
or local regulations.
Follow handling instructions carefully.
Keep ventilation openings, in the appliance clear
of obstruction.
Do not use mechanical devices or other means
to accelerate the defrosting process.
Children should be supervised to ensure that
they do not play with the appliance.
Do not store or install the appliance near
continuously operating ignition sources such as
open fl ames or a gas stove.
Do not operate near water or in a wet room.
Do not pierce or burn.
Be aware that refrigerants may not contain an
odor.
The appliance must be stored so as to prevent
mechanical damage from occurring.
All wiring must comply with local and national
codes and must be installed by a qualifi ed
electrician. Check the available power supply and
resolve any wiring problems before installing and
operating this appliance.
The rating plate located on the right side of the
appliance just above the power cord contains
electrical and other technical data.
This appliance is not intended for use by persons
(including children) whose physical, sensory or
mental capabilities may be different or reduced,
or who lack experience or knowledge, unless such
persons receive supervision or training to operate
the appliance by a person responsible for their
safety.
GROUNDING INSTRUCTIONS
This appliance must be grounded. Grounding
reduces the risk of electrical shock by providing an
escape wire for the electrical current.
This appliance has a cord that has a grounding
wire with a 3-prong plug. The power cord must be
plugged into an outlet that is properly grounded.
If the outlet is a 2-prong wall outlet, it must be
replaced with a properly grounded 3-prong wall
outlet. The serial rating plate indicates the voltage
and frequency the appliance is designed for.
WARNING - Improper use of the grounding
plug can result in a risk of electric shock.
Consult a qualifi ed electrician or service agent
if the grounding instructions are not completely
understood, or if doubt exists as to whether the
appliance is properly grounded.
Do not connect your appliance to extension
cords or together with another appliance in the
same wall outlet. Do not splice the power cord.
Do not under any circumstances cut or remove the
third ground prong from the power cord. Do not
use extension cords or ungrounded (two prongs)
adapters.
If the power supply cord is damaged, it must be
replaced by the manufacturer, its service agent or
similar qualifi ed person in order to avoid hazard.
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
Any person involved with working on the refrigerant
circuit should hold a current, valid certifi cate from
an industry accredited assessment authority which
authorizes their competence to handle refrigerants
safely in accordance with an industry recognized
assessment specifi cation.
Servicing shall only be performed as recommended
by the manufacturer. Maintenance and repair
requiring the assistance of other skilled personnel
shall be carried out under the supervision of
the person competent in the use of fl ammable
refrigerants.
When maintaining or disposing of the appliance the
refrigerant must be recovered properly and should
not be allowed to discharge to the air directly.
Information on servicing
1. Checks to the area: Prior to beginning work
on systems containing fl ammable refrigerants,
safety checks are necessary to ensure that the
risk of ignition is minimized. For repair to the
refrigerating system, the following precautions
shall be complied with prior to conducting work
on the system.
2. Work procedure: Work shall be undertaken
under a controlled procedure so as to minimize
the risk of a fl ammable gas or vapour being
present while the work is being performed.
3. General work area: All maintenance staff
and others working in the local area shall
be instructed on the nature of work being
carried out. Work in confi ned spaces shall be
avoided. The area around the work space shall
be sectioned off. Ensure that the conditions
within the work area have been made safe by
removing all fl ammable material.
4. Checking for the presence of refrigerant:
The are shall be checked with an appropriate
refrigerant detector prior to and during work
to ensure the technician is aware of potentially
ammable atmospheres. Ensure that the leak
detection equipment being used is suitable
for use with fl ammable refrigerants, i.e. non-
sparking, adequately sealed and intrinsically
safe.
5. Presence of fi re extinguisher: If any hot work is
to be conducted on the refrigeration equipment
or any associated parts, appropriate fi re
extinguishing equipment shall be available
to hand. Have a dry powder or C0
2
re
extinguisher adjacent to the work area.
6. No ignition sources: No person carrying out
work in relation to a refrigeration system which
involves exposing any pipe work that contains
or has contained fl ammable refrigerant shall use
any sources of ignition in such a manner that it
may lead to risk of fi re or explosion. All possible
ignition sources including cigarette smoking,
should be kept suffi ciently far away from the
site of installation, repairing, removing and
disposal during which fl ammable refrigerant can
possibly be released to the surrounding space.
Prior to work taking place, the area around the
equipment is to be surveyed to make sure there
are no fl ammable hazards or ignition risks. No
smoking signs shall be displayed.
7. Ventilated area: Ensure that the area is in the
open or that it is adequately ventilated before
breaking into the system or conducting any hot
work. A degree of ventilation shall continue
during the period that the work is carried out.
The ventilation should safely disperse any
released refrigerant and preferable expel it
externally into the atmosphere.
8. Checks to the refrigeration equipment: Where
electrical components are being changed, they
shall be fi t for the purpose and to the correct
specifi cation. At all times the manufacturer’s
maintenance and service guidelines shall be
followed. If in doubt consult the manufacturer’s
technical department for assistance.
3
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
The following checks shall be applied to installations
using fl ammable refrigerants:
The charge size is in accordance with the room
size within which the refrigerant containing
parts are installed.
The ventilation machinery and outlets are
operating adequately and are not obstructed.
If an indirect refrigerating circuit is being used,
the secondary circuit shall be checked for the
presence of refrigerant.
Marking to the equipment continues to be visible
and legible. Markings and signs that become
illegible must be corrected.
Refrigeration pipe or components are installed in
a position where they are unlikely to be exposed
to any substance which may corrode refrigerant
containing components, unless the components
are constructed of materials which are inherently
resistant to being corroded or are suitable
protected against being corroded.
9. Checks to electrical devices: Repair and
maintenance to electrical components shall
include initial safety checks and component
inspection procedures. If a fault exists that
could compromise safety, then no electrical
supply shall be connected to the circuit until it
is satisfactorily dealt with. If the fault cannot
be corrected immediately but it is necessary to
continue operation, an adequate temporary
solution shall be used. This shall be reported to
the owner of the equipment so all parties are
advised.
Initial safety checks shall include:
That capacitors are discharged. This shall be
done in a safe manner to avoid possibility of
sparking.
That no live electrical components and wiring
are exposed while charging, recovering or
purging the system.
That there is continuity of earth bonding.
Repairs to sealed components
1. During repairs to sealed components, all
electrical supplies shall be disconnected from
the equipment being worked upon prior to any
removal of sealed covers, etc. If it is absolutely
necessary to have an electrical supply to
equipment during servicing then a permanently
operating form of leak detection shall be located
at the most critical point to warn of a potentially
hazardous situation.
2. To ensure that by working on electrical
components the casing is not altered in such
a way that the level of protection is affected,
particular attention shall be paid to the
following:
Damage to cables, excessive number of
connections, terminals not made to original
specifi cation, damage to seals, incorrect fi tting
of glands, etc.
Ensure the apparatus is mounted securely.
Ensure that seals or sealing materials have
not degraded such that they no longer serve
the purpose of preventing the ingress of
ammable atmospheres. Replacement parts
shall be in accordance with the manufacturer’s
specifi cations.
Note: The use of silicon sealant may inhibit the
effectiveness of some types of leak detection
equipment. Intrinsically safe components do not
have to be isolated prior to working on them.
Repair to intrinsically safe components
Do not apply any permanent inductive or
capacitance loads to the circuit without ensuring
that this will not exceed the permissible voltage
and current permitted for the equipment in use.
Intrinsically safe components are the only types that
can be worked on while live in the presence of a
ammable atmosphere. The test apparatus shall
be at the correct rating. Replace components only
with parts specifi ed by the manufacturer. Other
parts may result in the ignition of refrigerant in the
atmosphere from a leak.
4
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
Removal and evacuation
When breaking into the refrigerant circuit to make
repairs or for any other purpose conventional
procedures shall be used. However, it is important
that the best practice is followed since fl ammability
is a consideration. The following procedures shall
be adhered to:
• Remove refrigerant.
Purge the circuit with inert gas.
• Evacuate.
Purge again with inert gas.
Open the circuit by cutting or brazing.
The refrigerant charge shall be recovered into
the correct recovery cylinders. The system shall
be fl ushed with OFN to render the unit safe. This
process may need to be repeated several times.
Compressed air or oxygen shall not be used for
this task.
Flushing shall be achieved by breaking the
vacuum in the system with OFN and continuing
to fi ll until the working pressure is achieved, then
venting to atmosphere and fi nally pulling down
to a vacuum. This process shall be repeated until
no refrigerant is within the system. When the
nal OFN charge is used, the system shall be
vented down to atmospheric pressure to enable
work to take place. This operation is absolutely
vital is brazing operations on the pipe-work are
to take place.
Ensure that the outlet for the vacuum pump is
not close to any ignition sources and there is
ventilation available.
Charging procedures
In addition to conventional charging procedures, the
following requirements shall be followed:
Ensure that contamination of different
refrigerants does not occur when using charging
equipment. Hoses or lines shall be as short as
possible to minimize the amount of refrigerant
contained in them.
Cylinders shall be kept upright.
Ensure that the refrigeration system is earthed
prior to charging the system with refrigerant.
Label the system when charging is complete, if
not already labeled.
Extreme care shall be taken not to overfi ll the
refrigeration system.
Prior to recharging the system it shall be
pressure tested with OFN. The system shall be
leak tested on completion of charging but prior
to commissioning. A follow up leak test shall be
carried out prior to leaving the site.
Cabling
Check that cabling will not be subject to wear,
corrosion, excessive pressure, vibration, sharp
edges or any other adverse environmental effects.
The check shall also take into account the effects of
aging or continual vibration from sources such as
compressors or fans.
Detection of fl ammable refrigerants
Under no circumstances shall potential sources of
ignition be used in the searching for or detection
of refrigerant leaks. A halide torch or any other
detector using a naked fl ame shall not be used.
Leak detection methods
The following leak detection methods are deemed
acceptable for systems containing fl ammable
refrigerants:
Electronic leak detectors shall be used to detect
ammable refrigerants but the sensitivity may
not be adequate or may need recalibration.
Detection equipment shall be calibrated in a
refrigerant-free area. Ensure that the detector is
not a potential source of ignition and is suitable
for the refrigerant used.
Leak detection equipment shall be set at a
percentage of the LFL of the refrigerant and
shall be calibrated to the refrigerant employed
and the appropriate percentage of gas (25%
maximum) is confi rmed.
Leak detection fl uids are suitable for use with
most refrigerants but the use of detergents
containing chlorine shall be avoided as the
chlorine may react with the refrigerant and
corrode the copper or pipe-work.
If a leak is suspected, all naked fl ames shall be
removed or extinguished.
If a leakage of refrigerant is found which
requires brazing, all of the refrigerant shall be
recovered from the system or isolated by means
of shut off valves in a part of the system remote
from the leak. Oxygen free nitrogen (OFN) shall
then be purged through the system both before
and during the brazing process.
5
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
Decommissioning
Before carrying out this procedure, it is essential
that the technician is completely familiar with the
equipment in all its detail. It is recommended good
practice that all refrigerants are recovered safely.
Prior to the task being carried out, an oil and
refrigerant sample shall be taken in case analysis is
required prior to re-use of reclaimed refrigerant. It
is essential that electrical power is available before
the task is commenced.
A. Become familiar with the equipment and its
operation.
B. Isolate system electrically.
C. Before attempting the procedure ensure that:
Mechanical handling equipment is available
if required for handling refrigerant cylinders.
All personal protective equipment is
available and being used correctly.
The recovery process is supervised at all
times by a competent person.
Recovery equipment and cylinders conform
to the appropriate standards.
D. Pump down refrigerant system, if possible.
E. If a vacuum is not possible, make a manifold so
that refrigerant can be removed from various
parts of the system.
F. Make sure that cylinder is situated on the scales
before recovery takes place.
G. Start the recovery machine and operate in
accordance with the manufacturer’s instructions.
H. Do not overfi ll cylinders. No more than 80%
volume liquid charge.
I. Do not exceed the maximum working pressure
of the cylinder, even temporarily.
J. When the cylinders have been fi lled correctly
and the process is completed, make sure that the
cylinders and the equipment are removed from
the site promptly and all isolation valves on the
equipment are closed off.
K. Recovered refrigerant shall not be charged into
another refrigeration system unless it has been
cleaned and checked.
Labeling
Equipment shall be labeled stating that it has been
decommissioned and emptied of refrigerant. The
label shall be dated and signed. Ensure that there
are labels on the equipment stating the equipment
contains fl ammable refrigerant.
Recovery
When removing refrigerant from a system, either for
servicing or decommissioning, it is recommended
good practice that all refrigerants are removed
safely.
When transferring refrigerant into cylinders, ensure
that only appropriate refrigerant recovers cylinders
are employed. Ensure that the correct number of
cylinders for holding the total system charge are
available. All cylinders to be used are designed
for the recovered refrigerant and labeled for that
refrigerant, i.e. special cylinders for the recovery
of refrigerant. Cylinders shall be complete with
pressure relief valve and associated shut-off valves
in good working order. Empty recovery cylinders
are evacuated and, if possible, cooled before
recovery occurs.
The recovery equipment shall be in good working
order with a set of instructions concerning the
equipment that is at hand and shall be suitable for
the recovery of fl ammable refrigerants. In addition,
a set of calibrated weighing scales shall be
available and in good working order. Hoses shall
be complete with leak-free disconnect couplings
and in good condition. Before using the recovery
machine, check that is it in satisfactory working
order, has been properly maintained and that any
associated electrical components are sealed to
prevent ignition in the event of a refrigerant leak.
Consult the manufacturer if in doubt.
The recovered refrigerant shall be returned to the
refrigerant supplier in the correct recovery cylinder
and the relevant waste transfer note shall be
arranged. Do not mix refrigerants in recovery units
and especially not in cylinders. If compressors or
compressor oils are to be removed, ensure that they
have been evacuated to an acceptable level to make
certain that fl ammable refrigerant does not remain
within the lubricant. The evacuation process shall be
carried out prior to returning the compressor to the
suppliers. Only electric heating to the compressor
body shall be employed to accelerate this process.
When oil is drained form a system, it shall be
carried out safely.
6
LOCATION
This air conditioner is designed for single or double
hung windows. Since window designs vary, it may
be necessary to make some modifi cations for safe
installation.
This air conditioner is not designed for vertical,
slider type windows or “through the wall”
installation.
Ensure that the window and frame are structurally
sound and free from dry or rotted wood.
Install the air conditioner in a window on a side
of the building which favors more shade than
sunlight. If the appliance must be in direct sunlight,
it is advisable to provide a shade awning over the
appliance to ensure effi cient functioning.
Do not install the appliance where leakage of
combustible gas is suspected.
This appliance is designed to evaporate
condensation under normal conditions. Under
extremely hot or humid conditions, excess
condensation may overfl ow to the outside. The
appliance should be installed where condensation
cannot drip on pedestrians or neighboring
properties.
Provide suffi cient clearance around the appliance
to allow ample air circulation. The rear of the
appliance should be outdoors, it should not be in
a garage or another room. Keep the appliance
away from obstacles and at least 76 cm (30 inches)
above the ground. Ensure that curtains and other
obstructions do not block air fl ow to the appliance.
76.2 cm
(30 inches)
50.8 cm
(20 inches)
50.8 cm
(20 inches)
12 cm
(30.5 in)
INSTALLATION INSTRUCTIONS
7
REQUIRED TOOLS
Screwdrivers: Phillips and fl at head.
Power Drill: 3.2mm (1/8”) diameter drill bit
• Pencil
• Measuring Tape
• Scissors
• Carpenter’s Level
ACCESSORIES
The following accessories are included with
the appliance and should be used during the
installation.
1. 13 mm (1/2 inch) screws (x7)
2. 9.5 mm (3/8 inch) screws (x4) (Factory installed
on some models.)
3. Safety Lock
4. Adhesive foam seal
5. Regular foam seal
6. “L” shaped mounting bracket (Factory installed
on some models.)
7. Bracket for wood windows (x2)
8. Bracket for vinyl windows (x2)
9. Weather stripping (x5)
10. Side curtains (x2)
1
2 3
4
5
6
9
8
7
10
INSTALLATION INSTRUCTIONS
L BRACKET
The “L” shaped bracket may come factory installed
on some models.
If the “L” shaped bracket is not pre-installed, attach
it to the top of the cabinet as shown below using the
provided 9.5 mm (3/8”) screws (x4).
8
INSTALLATION
Attach the side curtains to the appliance by sliding
the curtain frame into the side channel of the
cabinet. The curtains are labeled “left” and “right
on the frames. This refers to the left and right
sides of the appliance when facing the front of the
appliance.
Cut the regular foam seal to fi t the area of the
window sill that the air conditioner will rest on.
Place the air conditioner into the window with the
“L” shaped mounting bracket positioned in front of
the upper sash. The bottom of the cabinet should be
positioned on the recessed portion of the window
frame. Pull the upper window sash down until it
rests just behind the front fl ange of the “L” shaped
mounting bracket.
Expand the side curtains on each side and secure
the top of the frames to the window sash using one
13 mm (1/2”) screw on each side of the “L” shaped
mounting bracket.
Attach the clamps on the lower part of each curtain
to the window sill using one 13 mm (1/2”) screw on
each side of the cabinet.
Place the adhesive foam seal into the opening
between the inside and outside windows and
attached the safety lock to the outside window frame
using two 13 mm (1/2”) screws.
Check the Tilt Angle
The air conditioner should be tilted downward
towards the outside approximately 3° to 4°. This
tilt will encourage any condensed water to drain
to the outside. If any condensed water leaks to the
inside of the house, check the tilt angle and adjust
as necessary.
Measure the tilt angle from the front of the cabinet’s
edge. The difference in height between the front and
the back of the appliance, labeled “A” on the image
below, should be approximately 19 mm - 2.5 cm
(3/4” - 1”).
A
CONTROL PANEL
1. Remote Control Receiver: Ensure this receiver is not obscured by curtains or other items as it could
impact remote control functioning.
2. Follow Me Indicator Light: Illuminates when the Follow Me function is active. Follow Me can only be set
from the remote control.
3. Power Button: Used to turn the appliance on or off.
4. Mode Button: Used to choose the operating mode.
5. Up and Down Arrows: Used to adjust the set temperature in 1° increments and the timer function in 30
minute increments up to 10 hours and then in 1 hour increments up to 24 hours.
6. Display Panel: Displays the set temperature, the ambient temperature and the timer settings. To change
the temperature scale being displayed, press the up and down buttons at the same time.
7. Fan Button: Used to set the fan speed. The fan can be set to Low, Medium, High and Auto.
8. Wireless connect button: Used to connect to a wireless network.
9. Energy Saver Button: Used to set the energy saver function.
10. Filter Button: The indicator light will illuminate as a reminder to check the fi lter. Once the fi lter has been
cleaned, use this button to resume operation.
11. Sleep Button: Used to set the Sleep function.
12. Timer Button: Used to set the auto on and auto off timer.
1
2
3
4 5
6
7
8
9
10
11 12
9
OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS
10
REMOTE CONTROL
1. Display Panel: Displays the set temperature, the
ambient temperature and the timer settings. To
change the temperature scale being displayed,
press the °C/°F button.
2. Up and Down Arrows: Used to adjust the set
temperature in 1° increments and the timer
function in 30 minute increments up to 10 hours
and then in 1 hour increments up to 24 hours.
3. Mode Button: Used to choose the operating
mode.
4. Follow Me Button: Used to set the follow me
function.
5. °C/°F button: Use to change the temperature
scale.
6. LED Button: Press to turn the LED back light on
or off.
7. Power Button: Used to turn the appliance on or
off.
8. Sleep Button: Used to set the sleep function.
9. Fan Button: Used to set the fan speed. The fan
can be set to low, medium, high and auto.
10. Timer On Button: Used to set the auto on timer.
11. Timer Off Button: Used to set the auto off timer.
12. Energy Saver Button: Used to set the energy
saver function.
13. Lock Button: Press the °C/°F button and the
timer button at the same time to lock the remote
control and prevent the settings from being
inadvertently changed.
TEMP
1
2
3
4
5
6
7
8
9
10
11
12
13
11
OPERATING INSTRUCTIONS
REMOTE CONTROL BATTERIES
The remote control requires two AAA alkaline
batteries (included). Batteries should be replaced
when:
a) No sound is heard when attempting to program
the appliance.
b) The appliance does not respond to a command
issued by the remote control.
Battery replacement:
1. Slide the rear cover on the remote in the
direction of the arrow.
2. Insert two AAA batteries following the same
orientation depicted inside the battery chamber
(+/-).
3. Reinstall the rear cover.
4. If the remote control will not be used for
extended periods of time, the batteries should be
removed.
Notes:
Protect the remote control from high
temperatures, and keep it away from radiation
exposure.
Keep the control panel receiver out of direct
sunlight.
Do not mix old and new batteries.
Do not mix alkaline, standard (carbon-zinc), or
rechargeable (ni-cad, ni-mh,etc) batteries.
The remote operates within a range of 8 meters
(26 ft.) from the receiver located inside the main
appliance. Any obstruction between the receiver
and remote may cause signal interference,
limiting the ability to program the main unit.
OPERATING MODES
There are four operating modes to choose from.
Press the mode button repeatedly to choose the
desired mode. The adjacent indicator light will
illuminate to show which mode has been selected.
• Cool Mode
Choose cool mode to set the cooling function. Use
the up and down arrows to choose the desired
temperature. When cool mode is selected, the fan
speed can be adjusted by pressing the fan button.
• Dry Mode
Choose dry mode to remove excess moisture
from the air during periods of high humidity. All
water pulled from the air will condense inside the
appliance and drain out the back. The fan speed
will be automatically set and cannot be modifi ed in
dry mode.
• Fan Mode
Choose fan mode to run the internal fan without
engaging the cooling function. Press the fan button
repeatedly to choose the fan speed.
• Auto Mode
Auto mode is a pre-set factory program that
automatically defi nes the mode and fan speed
based on the set temperature, the ambient
temperature and the ambient humidity.
UP AND DOWN ARROWS
The up and down arrows will modify the set
temperature in 1° increments.
The up and down arrows will modify the set time of
the timer function in 0.5 hour increments up to 10
hours and then in 1 hour increments up to 24 hours
maximum.
12
OPERATING INSTRUCTIONS
SLEEP
The sleep function can be used to conserve energy
during sleeping hours.
When selected, the set temperature will increase
by 1°C/2°F every half hour for one full hour. The
appliance will hold the new set temperature for
6 hours before automatically returning to normal
operation.
The Sleep Function can be canceled at any time by
pressing the Sleep Button.
ENERGY SAVER
The energy saver function will automatically cycle
the fan on and off when the compressor is not in use
to minimize how often the compressor needs to turn
on.
When selected, the fan will continue to run for 3
minutes after the compressor turns off. The fan will
then cycle on for 2 minutes in 10 minute intervals
until the ambient temperature is above the set
temperature, at which point the compressor will turn
on and cooling will resume.
FOLLOW ME
There is a temperature sensor built into the remote
control that will monitor the room temperature. Keep
the remote control with you and the appliance will
automatically adjust the set temperature based on
the temperature where you are located.
The remote will display the temperature at its
location. The remote will send a signal to the air
conditioner every 3 minutes, so long as you remain
within range of the appliance.
The follow me light on the control panel will
illuminate for 5 seconds every 3 minutes to indicate
that it has received a signal from the remote. If the
appliance does not receive a signal from the remote
during any 7 minute interval it will beep to indicate
that the follow me mode has ended.
The maximum distance for the follow me feature is
8 meters (26 feet). This feature is available in cool
and auto modes.
WIRELESS CONNECTION
This appliance can be controlled with a wireless
application on your wireless device.
Visit https://www.danby.com/support/#apps
to download the application and learn about its
operation.
OPERATING INSTRUCTIONS
13
TIMER
The timer can be used to turn the appliance on or
off after a set period of time.
The control panel has one timer button. Press once
to set the auto off timer and twice to set the auto off
timer. The remote control has separate timer on and
timer off buttons.
Auto On Timer
1. Press the timer on button on the remote or press
the timer button on the control panel twice.
2. Use the up and down arrows to select the
desired amount of time before the appliance
should turn on.
3. Use the mode button to select the desired mode.
4. Use the fan button to select the desired fan
speed.
5. The time selected will appear on the display
panel and will count down until the appliance
turns on.
Auto Off Timer
1. Press the timer off button on the remote or press
the timer button on the control panel once.
2. Use the up and down arrows to select the
desired amount of time before the appliance
should turn off. The appliance will run in the
currently selected mode.
3. The time selected will appear on the display
panel and will count down until the appliance
turns off.
Using On and Off Timers Simultaneously
The on and off timers can be used at the same time.
To set the appliance to turn on, run for a set period
of time and then turn off, set the auto on timer fi rst
and then set the auto off timer.
To set the appliance to run for a period of time, turn
off for a period of time and then turn back on, set
the auto off timer fi rst and then set the auto on timer.
Both indicator lights will illuminate and the display
will count down to the appliance either turning off
or on, whichever function was set fi rst.
The timer will not cycle the appliance on and off
indefi nitely. The on and off timers will function one
time and then the appliance will return to regular
functioning.
Turning the appliance off or unplugging the
appliance will clear all memory settings, including
the timer.
CARE & MAINTENANCE
AIR FILTER
The air fi lter should be cleaned approximately every
2 weeks. The air fi lter may require more frequent
cleaning if there is signifi cant dander or fur in the
air.
Approximately every two weeks, the fi lter indicator
light on the control panel will illuminate as a
reminder to clean the fi lter. Follow the steps below
to clean the fi lter and return the appliance to normal
functioning.
1. The air fi lter is located behind the front intake
grill. To remove the air fi lter, grasp the fi lter tab
on the right side of the grill and slide it out to the
right. If the front intake grill has two indents, pull
the grill forward to remove the air fi lter.
2. Use a vacuum cleaner with a soft brush
attachment to remove any large debris or dust
build up from the air fi lter.
3. Wash the fi lter in lukewarm, soapy water, below
40°C (104°F), or use a neutral cleaning agent.
4. Rinse the fi lter with clean water and dry
thoroughly before reinstalling in the appliance.
5. Press the fi lter button on the control panel to
resume normal functioning.
Note: Do not operate the appliance without the air
lter installed.
ERROR CODES
If the display panel shows any of the below error
codes, unplug the appliance, let it stand for 5-10
minutes and then plug it back in. If the error
persists, call for service.
AS - Room temperature sensor error
HS - Electric heating sensor error
. - Evaporator temperature sensor error
CLEANING
To avoid possible electric shock, ensure that the
appliance is unplugged before performing any
cleaning or maintenance.
The outside of the appliance can be wiped clean
with a soft cloth or with a lukewarm, damp cloth if
necessary.
Do not use gasoline, benzene, thinner or any
other chemicals to clean this appliance as these
substances can cause damage to the fi nish and
deformation of plastic parts.
Never pour water directly onto the appliance as this
will cause deterioration of electrical components
and wiring insulation.
END OF SEASON CARE
Before removing the appliance from service for the
year, operate the appliance on high fan mode for
half a day to ensure the inside of the appliance
is dry. This will help avoid the growth of mold or
mildew inside the appliance. Ensure the fi lter is
clean and dry. Store the appliance covered in a dry
location.
Note: When installing or removing the appliance
from the window, ensure that caution is taken to
prevent it from falling backward. It is recommended
that installation or removal is completed with
assistance to prevent injury to persons or damage to
property or the appliance.
DISPOSAL
Check for local regulatory compliance regarding
approved and safe disposal of this appliance.
14
15
TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE
Appliance will not operate Plug is not fully inserted into the wall outlet
Blown fuse or circuit breaker
Insuffi cient cooling • Air lter is dirty
Blocked air fl ow
Appliance size is too small for application
Noise Inadequate support in window installation
Odors Formation of mold or mildew on internal wet surfaces
Place an algaecide tablet in base pan; push the tablet through
the grill on either side of the appliance
Water dripping inside Appliance is not properly angled to allow water to drain to the
outside
Water dripping outside On very hot or humid days dripping water from the back of the
appliance is normal
Frost build up When outdoor temperatures are below 18.3°C (65°F) frost may
form when the appliance is in cooling mode
Switch the appliance to fan only mode until the frost melts
Danby Consumer Care: 1-800-263-2629 or consumerservice@danby.com
Hours of operation:
Monday to Thursday 8:30 am - 6:00 pm Eastern Standard Time
Friday 8:30 am - 4:00 pm Eastern Standard Time
Information in this manual is subject to change without notice.
This Class B digital apparatus complies with the
Canadian ICES-003 standard. CAN ICES-3 (B)
This equipment has been tested and found to
comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection
against interference in a residential installation.
This equipment generates, uses and can radiate
radio frequency energy and, if not installed and
used in accordance with the instructions, may cause
interference to radio communications. However,
there is no guarantee that interference will not occur
in a particular installation.
If this equipment does cause interference to radio
or television reception, which can be determined
by turning the equipment off and on, the user is
encouraged to try to correct the interference by one
or more of the following measures:
1. Reorient or relocate the receiving antenna.
2. Increase the separation between the equipment
and receiver.
3. Connect the equipment into an outlet on a
circuit different from that to which the receiver is
connected.
4. Consult the dealer or an experienced radio/TV
technician for help.
Changes or modifi cations not approved by the
party responsible for FCC compliance could void
the user’s authority to operate the equipment.
This appliance complies with Part 15 of the FCC
Rules.
Operation is subject to the following two conditions:
1. This device may not cause interference.
2. This device must accept any interference
received, including interference that may cause
undesired operation.
LIMITED IN-HOME APPLIANCE WARRANTY
This quality product is warranted to be free from manufacturer’s defects in material and workmanship, provided that the unit is used under the normal operating
conditions intended by the manufacturer.
This warranty is available only to the person to whom the unit was originally sold by Danby Products Limited (Canada) or Danby Products Inc. (U.S.A.) (hereafter
“Danby”) or by an authorized distributor of Danby, and is non-transferable.
TERMS OF WARRANTY
Plastic parts, are warranted for thirty (30) days only from purchase date, with no extensions provided.
First Year
During the rst twelve (12) months, any functional parts of this product found to be defective, will be repaired or replaced, at warrantor’s
option, at no charge to the ORIGINAL purchaser.
To obtain
Danby reserves the right to limit the boundaries of “In Home Service” to the proximity of an Authorized Service Depot. Any app liance
Service
requiring service outside the limited boundaries of “In Home Service” , it will be the consumer’s responsibility to transport the appliance (at
their own expense) to the original retailer (point of purchase) or a service depot for repair. See “Boundaries of In Home Serv ice” below.
Contact your dealer from whom your unit was purchased, or contact your nearest authorized Danby service depot, where service
must be performed by a qualied service technician.
If service is performed on the units by anyone other than an authorized service depot, or the unit is used for commercial appli cation, all
obligations of Danby under this warranty shall be void.
Boundaries of
If the appliance is installed in a location that is 100 kilometers (62 miles) or more from the nearest service center your unit must be
In Home Service
delivered to the nearest authorized Danby Service Depot, as service must only be performed by a technician qualied and certif ied for
warranty service by Danby. Transportation charges to and from the service location are not protected by this warranty and are t he
responsibility of the purchaser.
Nothing within this warranty shall imply that Danby will be responsible or liable for any spoilage or damage to food or other c ontents of this appliance, whether due
to any defect of the appliance, or its use, whether proper or improper.
EXCLUSIONS
Save as herein provided, Danby, there are no other warranties, conditions, representations or guarantees, express or implied, m ade or intended by Danby or its
authorized distributors and all other warranties, conditions, representations or guarantees, including any warranties, conditio ns, representations or guarantees
under any Sale of Goods Act or like legislation or statue is hereby expressly excluded. Save as herein provided, Danby shall no t be responsible for any damages
to persons or property, including the unit itself, howsoever caused or any consequential damages arising from the malfunction o f the unit and by the purchase of
the unit, the purchaser does hereby agree to indemnify and hold harmless Danby from any claim for damages to persons or propert y caused by the unit.
GENERAL PROVISIONS
No warranty or insurance herein contained or set out shall apply when damage or repair is caused by any of the following:
1) Power failure.
2) Damage in transit or when moving the appliance.
3) Improper power supply such as low voltage, defective house wiring or inadequate fuses.
4) Accident, alteration, abuse or misuse of the appliance such as inadequate air circulation in the room or abnormal operating con ditions
(extremely high or low room temperature).
5) Use for commercial or industrial purposes (ie. If the appliance is not installed in a domestic residence).
6) Fire, water damage, theft, war, riot, hostility, acts of God such as hurricanes, oods etc.
7) Service calls resulting in customer education.
8) Improper Installation (ie. Building-in of a free standing appliance or using an appliance outdoors that is not approved for out door application).
Proof of purchase date will be required for warranty claims; so, please retain bills of sale. In the event warranty service is required, present this document to our
AUTHORIZED SERVICE DEPOT.
Danby Products Limited
PO Box 1778, Guelph, Ontario, Canada N1H 6Z9
Telephone: (519) 837-0920 FAX: (519) 837-0449
Danby Products Inc.
PO Box 669, Findlay, Ohio, U.S.A. 45840
Telephone: (419) 425-8627 FAX: (419) 425-8629
04/09
1-800-263-2629
Warranty Service
In-home
Transportation charges to and from the service location are not protected by this warranty and are the responsibility of the purchaser.
During the first twenty four (24) months, any functional parts of this product found to be defective, will be repaired
or replaced, at warrantor’s option, at no charge to the original purchaser.
Contact the dealer where the unit was purchased, or contact the nearest authorized Danby service depot, where
service must be performed by a qualified service technician. If service is performed on the unit by anyone other
than an authorized service depot, all obligations of Danby under this warranty shall be void.
It is the responsibility of the purchaser to transport the appliance to the nearest authorized service depot.
First 24 months
To obtain service
LIMITED “CARRY IN” WARRANTY
This quality product is warranted to be free from manufacturer’s defects in material and workmanship, provided that the unit is used
under the normal operating conditions intended by the manufacturer.
This warranty is available only to the person to whom the unit was originally sold by Danby Products Limited (Canada) or Danby
Products Inc. (U.S.A.) (hereafter “Danby”) or by an authorized distributor of Danby, and is non-transferable.
TERMS OF WARRANTY
Plastic parts are warranted for thirty (30) days from the date of purchase, with no extensions provided.
Nothing within this warranty shall imply that Danby will be responsible or liable for any spoilage or damage to food or other
contents of this appliance, whether due to any defect of the appliance, or its use, whether proper or improper.
EXCLUSIONS
Save as herein provided, by Danby, there are no other warranties, conditions, representations or guarantees, express or implied, made
or intended by Danby or its authorized distributors and all other warranties, conditions, representations or guarantees, including any
warranties, conditions, representations or guarantees under any Sale of Goods Act or like legislation or statute is hereby expressly
excluded. Save as herein provided, Danby shall not be responsible for any damages to persons or property, including the unit itself,
howsoever caused or any consequential damages arising from the malfunction of the unit and by the purchase of the unit, the
purchaser does hereby agree to indemnify and hold harmless Danby from any claim for damages to persons or property caused by
the unit.
GENERAL PROVISIONS
No warranty or insurance herein contained or set out shall apply when damage or repair is caused by any of the following:
1) Power failure.
2) Damage in transit or when moving the appliance.
3) Improper power supply such as low voltage, defective house wiring or inadequate fuses.
4) Accident, alteration, abuse or misuse of the appliance such as inadequate air circulation in the room or abnormal operating
conditions (ie. extremely high or low room temperature).
5) Use for commercial or industrial purposes (ie. If the appliance is not installed in a domestic residence).
6) Fire, water damage, theft, war, riot, hostility, acts of God such as hurricanes, floods etc.
7) Service calls resulting in customer education.
8) Improper Installation (ie. Building-in of a free standing appliance or using an appliance outdoors that is not approved for outdoor
application, including but not limited to: garages, patios, porches or anywhere that is not properly insulated or climate controlled).
Proof of purchase date will be required for warranty claims; retain bills of sale. In the event that warranty service is required, present
the proof of purchase to our authorized service depot.
Warranty Service
Carry In
Danby Products Limited
PO Box 1778, Guelph, Ontario, Canada N1H 6Z9
Telephone: (519) 837-0920 FAX: (519) 837-0449
Danby Products Inc.
PO Box 669, Findlay, Ohio, U.S.A. 45840
Telephone: (419) 425-8627 FAX: (419) 425-8629
1-800-263-2629
04/17
17
Bienvenue
Bienvenue à la famille Danby. Nous sommes fi ers de la qualité de nos produits et nous croyons
en le service fi able. Nous vous suggérons de lire ce manual d’utilisation avant de brancher
votre nouvel appareil car il contient des informations inportantes sur l’utilisation, la sécurité, le
dépannage et la maintenance, afi n d’assurer la fi abilité et la longévité de votre appareil.
Visitez www.Danby.com pour accéder aux outils d’autoservice, aux FAQ et bien plus encore. Pour
obtenir de l’aide supplémentaire, composez 1-800-263-2629.
Notez les informations ci-dessous; Vous aurez besoin de cette information pour obtenir un
service sous garantie.
Vous devez fournir le reçu d’achat original pour valider votre garantie et recevoir le service.
Numéro de modèle: _____________________________________________
Numéro de serie: _______________________________________________
Date d’achat: __________________________________________________
Besoin d’assistance?
Avant d’appeler pour service, voici quelques choses que vous pouvez faire pour nous
aider à mieux vous servir.
Lire ce manuel du propriétaire:
Il contient des instructions pour vous aider à utiliser et à maintenir votre appareil
correctement.
Si vous recevez un appareil endommagé:
Contactez immédiatement le revendeur ou l’entrepreneur qui vous a vendu l’appareil.
Gagnez du temps et de l’argent:
Avant d’appeler pour service, consultez la section de dépannage à la fi n de ce manuel.
Cette section vous aidera à résoudre les problèmes courants pouvant survenir.
1-800-26- Danby
(1-800-263-2629)
18
GARDEZ CES INSTRUCTIONS!
ATTENTION: RISQUE D’INCENDIE
Fluide frigorigène infl ammable utilisé. Lors
de l’entretien ou de la mise au rebut du
climatiseur, le réfrigérant ne doit pas pouvoir
s’échapper à l’air libre.
INSTRUCTIONS DE MISE À LA TERRE
Cet appareil doit être mis à la terre. La mise à
la terre réduit le risque de choc électrique en
fournissant un fi l d’échappement pour le courant
électrique.
Cet appareil possède un cordon doté d’un fi l de
mise à la terre avec une fi che à 3 broches. Le
cordon d’alimentation doit être branché sur une
prise correctement mise à la terre. Si la sortie
est une prise murale à 2 broches, elle doit être
remplacée par une prise murale à 3 broches
correctement mise à la terre. La plaque signalétique
en série indique la tension et la fréquence
auxquelles l’appareil est conçu.
AVERTISSEMENT - Une utilisation incorrecte de la
che de mise à la terre peut entraîner un risque
d’électrocution. Consultez un électricien qualifi é
ou un agent de service si les instructions de mise
à la terre ne sont pas complètement comprises ou
s’il existe un doute quant à savoir si l’appareil est
correctement mis à la terre.
Ne branchez pas votre appareil à des rallonges
ou avec un autre appareil dans la même prise
murale. Ne pas épisser le cordon d’alimentation.
Ne coupez ou retirez en aucun cas la troisième
broche du cordon d’alimentation. N’utilisez pas de
cordons de prolongement ou d’adaptateurs sans
mise à la terre (deux broches).
Si le cordon d’alimentation est endommagé, il doit
être remplacé par le fabricant, son agent de service
ou une personne qualifi ée similaire afi n d’éviter tout
risque.
Consignes de sécurité importantes
LIRE ET SUIVRE TOUTES LES INSTRUCTIONS DE SÉCURITÉ
EXIGENCES DE SÉCURITÉ
DANGER: Risque d’incendie ou d’explosion.
Fluide frigorigène infl ammable utilisé. Ne pas
endommager le circuit de réfrigérant.
Assurez-vous que les réparations sont effectuées
par du personnel autorisé par l’usine, afi n de
minimiser les dommages au produit ou les
problèmes de sécurité.
Consultez le manuel de réparation ou le guide
du propriétaire avant de tenter de réparer
ce produit. Toutes les précautions de sécurité
doivent être suivies.
Éliminer correctement conformément aux
réglementations fédérales ou locales.
Suivez attentivement les instructions de
manipulation.
Veillez à ce que les ouvertures de ventilation de
l’appareil ne soient pas obstruées.
N’utilisez pas d’appareils mécaniques ou
d’autres moyens pour accélérer le processus de
dégivrage.
Les enfants doivent être surveillés pour s’assurer
qu’ils ne jouent pas avec l’appareil.
Ne rangez pas et n’installez pas l’appareil à
proximité de sources d’allumage fonctionnant
en continu, telles que des fl ammes nues ou une
cuisinière à gaz.
Ne pas utiliser près de l’eau ou dans une pièce
humide.
Ne pas percer ou brûler.
Sachez que les réfrigérants peuvent ne pas
contenir d’odeur.
L’appareil doit être rangé de manière à éviter
tout dommage mécanique.
Tout le câblage doit être conforme aux codes locaux
et nationaux et doit être installé par un électricien
qualifi é. Vérifi ez l’alimentation disponible et
résolvez tout problème de câblage avant d’installer
et d’utiliser cet appareil.
La plaque signalétique située sur le côté droit
de l’appareil, juste au-dessus du cordon
d’alimentation, contient des données électriques et
techniques.
Cet appareil n’est pas destiné à être utilisé par des
personnes (y compris des enfants) dont les capacités
physiques, sensorielles ou mentales peuvent
être différentes ou réduites, ou qui manquent
d’expérience ou de connaissances, à moins que
ces personnes ne soient supervisées ou formées
pour faire fonctionner l’appareil par une personne
responsable de leur utilisation. sécurité.
Toute personne impliquée dans le travail sur le
circuit de fl uide frigorigène doit détenir un certifi cat
en cours de validité, délivré par une autorité
d’évaluation accréditée du secteur, attestant de sa
compétence pour manipuler les fl uides frigorigènes
en toute sécurité, conformément à une spécifi cation
d’évaluation reconnue par l’industrie.
L’entretien ne doit être effectué que selon les
recommandations du fabricant. L’entretien et les
réparations nécessitant l’assistance d’un autre
personnel qualifi é doivent être effectués sous
la supervision de la personne compétente pour
l’utilisation de réfrigérants infl ammables.
Lors de l’entretien ou de la mise au rebut de
l’appareil, le réfrigérant doit être récupéré
correctement et ne doit pas être autorisé à se
décharger directement dans l’air.
Informations sur le service
1. Chèques à la région: Avant de commencer
à travailler sur des systèmes contenant des
frigorigènes infl ammables, des contrôles de
sécurité sont nécessaires pour réduire au
minimum le risque d’infl ammation. Pour réparer
le système de réfrigération, les précautions
suivantes doivent être respectées avant de
procéder à des travaux sur le système.
2. Procédure de travail: Les travaux doivent être
effectués selon une procédure contrôlée, de
manière à minimiser le risque de présence
de gaz ou de vapeurs infl ammables pendant
l’exécution des travaux.
3. Zone de travail générale: Tout le personnel de
maintenance et les autres personnes travaillant
dans la zone locale doivent être informés de la
nature des travaux effectués. Les travaux dans
des espaces confi nés doivent être évités. La zone
autour de l’espace de travail doit être divisée.
Assurez-vous que les conditions dans la zone
de travail ont été sécurisées en retirant tout
matériau infl ammable.
4. Vérifi cation de la présence de réfrigérant: Le
sont doivent être vérifi és avec un détecteur de
réfrigérant approprié avant et pendant le travail
pour s’assurer que le technicien est conscient
des atmosphères potentiellement infl ammables.
Assurez-vous que l’équipement de détection des
fuites utilisé convient aux fl uides frigorigènes
infl ammables, c’est-à-dire qu’il ne produit pas
d’étincelles, est correctement scellé et de sécurité
intrinsèque.
5. Présence d’extincteur: Si des travaux à chaud
doivent être effectués sur l’équipement de
réfrigération ou sur toute pièce associée, un
équipement d’extinction d’incendie approprié
doit être disponible. Avoir un extincteur à
poudre sèche ou au C02 adjacent à la zone de
travail.
6. Aucune source d’infl ammation: Aucune
personne effectuant des travaux en rapport
avec un système de réfrigération impliquant
l’exposition de tuyauteries contenant ou ayant
contenu un réfrigérant infl ammable ne doit
utiliser une source d’infl ammation de manière à
entraîner un risque d’incendie ou d’explosion.
Toutes les sources d’infl ammation possibles, y
compris le tabagisme, doivent être suffi samment
éloignées du lieu d’installation, de réparation,
de retrait et d’élimination, pendant lesquelles un
réfrigérant infl ammable peut éventuellement être
rejeté dans l’espace environnant. Avant le début
des travaux, la zone autour de l’équipement
doit être inspectée pour s’assurer qu’il n’y a
pas de danger d’infl ammabilité ou de risque
d’infl ammation. Aucun signe de fumer ne doit
être affi ché.
7. Zone ventilée: Assurez-vous que la zone
est à l’air libre ou qu’elle est correctement
ventilée avant de pénétrer dans le système ou
d’effectuer des travaux à chaud. Une certaine
ventilation doit être maintenue pendant la
durée des travaux. La ventilation doit disperser
en toute sécurité tout fl uide réfrigérant libéré
et de préférence l’expulser de l’extérieur vers
l’atmosphère.
8. Contrôles à l’équipement de réfrigération:
Lorsque des composants électriques sont
remplacés, ils doivent être adaptés à l’usage
prévu et aux spécifi cations appropriées.
Respectez à tout moment les directives
du fabricant en matière d’entretien et de
maintenance. En cas de doute, consultez le
service technique du fabricant.
Consignes de sécurité importantes
LIRE ET SUIVRE TOUTES LES INSTRUCTIONS DE SÉCURITÉ
19
Les contrôles suivants doivent être appliqués aux
installations utilisant des réfrigérants infl ammables:
La taille de la charge est conforme à la taille de
la pièce dans laquelle les pièces contenant le
réfrigérant sont installées.
Les machines de ventilation et les sorties
fonctionnent de manière adéquate et ne sont pas
obstruées.
Si un circuit de réfrigération indirect est utilisé,
le circuit secondaire doit être vérifi é pour la
présence de réfrigérant.
Le marquage sur l’équipement continue d’être
visible et lisible. Les marques et les signes qui
deviennent illisibles doivent être corrigés.
Les tuyaux ou composants de réfrigération sont
installés dans une position où ils ne risquent
pas d’être exposés à une substance susceptible
de corroder les composants contenant du
réfrigérant, à moins que les composants
ne soient construits avec des matériaux
intrinsèquement résistants à la corrosion ou
protégés de manière adéquate.
9. Contrôles aux appareils électriques: La
réparation et la maintenance des composants
électriques doivent inclure les contrôles de
sécurité initiaux et les procédures d’inspection
des composants. S’il existe un défaut
susceptible de compromettre la sécurité, aucune
alimentation électrique ne doit être connectée
au circuit jusqu’à ce que le problème soit
résolu. Si le défaut ne peut pas être corrigé
immédiatement mais qu’il est nécessaire de
poursuivre le fonctionnement, une solution
temporaire adéquate doit être utilisée. Cela doit
être signalé au propriétaire de l’équipement afi n
que toutes les parties soient informées.
Les contrôles de sécurité initiaux doivent inclure:
Que les condensateurs sont déchargés. Ceci
doit être fait de manière sûre pour éviter la
possibilité d’étincelles.
Qu’aucun composant ni câblage électrique sous
tension ne soit exposé pendant le chargement, la
récupération ou la purge du système.
Qu’il existe une continuité de la mise à la terre.
Réparation de composants scellés
1. Lors de la réparation de composants scellés,
toutes les alimentations électriques doivent
être débranchées de l’équipement utilisé
avant toute dépose de couvercles scellés,
etc. S’il est absolument nécessaire de prévoir
une alimentation électrique de l’équipement
pendant l’entretien, une détection des fuites
fonctionnant en permanence doit être situé au
point le plus critique pour avertir d’une situation
potentiellement dangereuse.
2. Afi n de garantir qu’en manipulant des
composants électriques, le boîtier ne soit pas
modifi é de telle sorte que le niveau de protection
soit affecté, une attention particulière doit être
accordée aux éléments suivants:
Dommages aux câbles, nombre excessif
de connexions, bornes non conformes aux
spécifi cations d’origine, dommages aux joints,
mauvais montage des presse-étoupes, etc.
Assurez-vous que l’appareil est bien monté.
Assurez-vous que les joints ou les matériaux
d’étanchéité ne se sont pas dégradés de telle
sorte qu’ils ne servent plus à empêcher la
pénétration d’atmosphères infl ammables. Les
pièces de rechange doivent être conformes aux
spécifi cations du fabricant.
Remarque: l’utilisation d’un produit d’étanchéité à
base de silicone peut nuire à l’effi cacité de certains
types d’équipement de détection de fuites. Les
composants de sécurité intrinsèque ne doivent pas
nécessairement être isolés avant de travailler dessus.
Réparation de composants à sécurité intrinsèque
N’appliquez aucune charge inductive ou capacitive
permanente sur le circuit sans vous assurer que cela
ne dépassera pas la tension et le courant autorisés
pour l’équipement utilisé. Les composants à sécurité
intrinsèque sont les seuls types sur lesquels on
peut travailler tout en vivant dans une atmosphère
infl ammable. L’appareil d’essai doit avoir la cote
correcte. Remplacez les composants uniquement
par des pièces spécifi ées par le fabricant. D’autres
pièces peuvent provoquer l’infl ammation de
réfrigérant dans l’atmosphère par une fuite.
Consignes de sécurité importantes
LIRE ET SUIVRE TOUTES LES INSTRUCTIONS DE SÉCURITÉ
20
Consignes de sécurité importantes
LIRE ET SUIVRE TOUTES LES INSTRUCTIONS DE SÉCURITÉ
Enlèvement et évacuation
Lorsque vous pénétrez dans le circuit de fl uide
frigorigène pour effectuer des réparations ou à
toute autre fi n, vous devez utiliser des procédures
classiques. Cependant, il est important que la
meilleure pratique soit suivie car l’infl ammabilité est
une considération. Les procédures suivantes doivent
être respectées:
Retirer le réfrigérant.
Purger le circuit avec du gaz inerte.
• Évacuer.
Purger à nouveau avec un gaz inerte.
Ouvrir le circuit en coupant ou en soudant.
La charge de réfrigérant doit être récupérée
dans les bonnes bouteilles de récupération.
Le système doit être rincé avec OFN pour
sécuriser l’unité. Ce processus peut avoir besoin
d’être répété plusieurs fois. L’air comprimé ou
l’oxygène ne doit pas être utilisé pour cette
tâche.
Le rinçage doit être réalisé en rompant le vide
dans le système avec OFN et en continuant à se
remplir jusqu’à atteindre la pression de travail,
puis en relâchant dans l’atmosphère et en tirant
nalement vers le vide. Ce processus doit être
répété jusqu’à ce qu’il n’y ait plus de réfrigérant
dans le système. Lorsque la dernière charge
OFN est utilisée, le système doit être purgé
à la pression atmosphérique pour permettre
le travail. Cette opération est absolument
essentielle si des opérations de brasage sur la
tuyauterie doivent avoir lieu.
Assurez-vous que la sortie de la pompe à
vide ne se trouve pas à proximité de sources
d’infl ammation et qu’il existe une ventilation.
Procédures de charge
Outre les procédures de chargement classiques, les
exigences suivantes doivent être respectées:
Assurez-vous que les différents réfrigérants
ne soient pas contaminés lors de l’utilisation
d’un équipement de charge. Les tuyaux ou les
conduites doivent être aussi courts que possible
pour minimiser la quantité de réfrigérant qu’ils
contiennent.
Les bouteilles doivent être maintenues debout.
Assurez-vous que le système de réfrigération
est mis à la terre avant de le charger avec du
réfrigérant.
Étiquetez le système lorsque le chargement est
terminé, s’il ne l’est pas déjà.
Un soin extrême doit être pris pour ne pas trop
remplir le système de réfrigération.
Avant de recharger le système, il doit être
testé sous pression avec OFN. Le système doit
être soumis à un test d’étanchéité à la fi n du
chargement mais avant la mise en service. Un
contrôle d’étanchéité doit être effectué avant de
quitter le site.
Le câblage
Vérifi ez que le câblage ne sera pas soumis à
l’usure, à la corrosion, à une pression excessive,
aux vibrations, aux arêtes vives ou à tout autre
effet néfaste sur l’environnement. La vérifi cation
doit également prendre en compte les effets
du vieillissement ou des vibrations continuelles
provenant de sources telles que les compresseurs ou
les ventilateurs.
Détection de réfrigérants infl ammables
En aucun cas, des sources d’infl ammation
potentielles ne doivent être utilisées pour rechercher
ou détecter des fuites de réfrigérant. Une lampe à
incandescence ou tout autre détecteur utilisant une
amme nue ne doit pas être utilisé.
Méthodes de détection de fuite
Les méthodes de détection des fuites suivantes sont
jugées acceptables pour les systèmes contenant des
réfrigérants infl ammables:
Des détecteurs de fuites électroniques doivent
être utilisés pour détecter les réfrigérants
infl ammables, mais la sensibilité peut ne pas
être adéquate ou nécessiter un réétalonnage.
L’équipement de détection doit être étalonné
dans une zone sans réfrigérant. Assurez-vous
que le détecteur n’est pas une source potentielle
d’infl ammation et qu’il convient au réfrigérant
utilisé.
L’équipement de détection de fuites doit être
réglé sur un pourcentage de la LF du réfrigérant
et doit être calibré avec le réfrigérant utilisé et le
pourcentage de gaz approprié (25% maximum)
est confi rmé.
Les fl uides de détection des fuites peuvent
être utilisés avec la plupart des réfrigérants,
mais l’utilisation de détergents contenant du
chlore doit être évitée car le chlore peut réagir
avec le réfrigérant et corroder le cuivre ou les
tuyauteries.
Si une fuite est suspectée, toutes les fl ammes
nues doivent être supprimées ou éteintes.
Si une fuite de réfrigérant nécessitant un
brasage est détectée, tout le réfrigérant doit
être récupéré du système ou isolé au moyen
de vannes d’arrêt dans une partie du système
éloignée de la fuite. L’azote libre d’oxygène
(OFN) doit ensuite être purgé à travers le
système avant et pendant le processus de
brasage.
21
Consignes de sécurité importantes
LIRE ET SUIVRE TOUTES LES INSTRUCTIONS DE SÉCURITÉ
Déclassement
Avant d’effectuer cette procédure, il est essentiel que
le technicien connaisse parfaitement l’équipement
dans tous ses détails. Il est recommandé,
conformément aux bonnes pratiques, que tous les
réfrigérants soient récupérés en toute sécurité. Avant
l’exécution de la tâche, un échantillon d’huile et de
réfrigérant doit être prélevé au cas où une analyse
serait nécessaire avant de réutiliser le réfrigérant
récupéré. Il est essentiel que l’alimentation électrique
soit disponible avant le début de la tâche.
A. Familiarisez-vous avec l’équipement et son
fonctionnement.
B. Isoler le système électriquement.
C. Avant de tenter la procédure, assurez-vous que:
Un équipement de manutention mécanique
est disponible si nécessaire pour la
manipulation des bouteilles de réfrigérant.
Tous les équipements de protection
individuelle sont disponibles et utilisés
correctement.
Le processus de récupération est supervisé à
tout moment par une personne compétente.
L’équipement de récupération et les bouteilles
sont conformes aux normes appropriées.
D. Pomper le système de réfrigérant, si possible.
E. Si le vide n’est pas possible, créez un collecteur
afi n que le réfrigérant puisse être éliminé de
différentes parties du système.
F. Assurez-vous que le cylindre est situé sur la
balance avant la récupération.
G. Démarrez la machine de récupération et utilisez-
la conformément aux instructions du fabricant.
H. Ne pas trop remplir les bouteilles. Pas plus de
80% de volume de charge liquide.
I. Ne dépassez pas la pression de service
maximale du cylindre, même temporairement.
J. Lorsque les bouteilles ont été remplies
correctement et que le processus est terminé,
assurez-vous que les bouteilles et l’équipement
sont retirés du site rapidement et que toutes
les vannes d’isolement de l’équipement sont
fermées.
K. Le réfrigérant récupéré ne doit pas être chargé
dans un autre système de réfrigération à moins
d’avoir été nettoyé et vérifi é.
Étiquetage
L’équipement doit porter une étiquette indiquant
qu’il a été mis hors service et vidé du réfrigérant.
L’étiquette doit être datée et signée. Assurez-vous
qu’il y a des étiquettes sur l’équipement indiquant
que celui-ci contient du réfrigérant infl ammable.
Récupération
Lorsque vous retirez du fl uide frigorigène d’un
système, que ce soit pour un entretien ou une mise
hors service, il est recommandé de procéder à
l’élimination de tous les fl uides frigorigènes en toute
sécurité.
Lors du transfert du réfrigérant dans les bouteilles,
assurez-vous que seul le récupérateur approprié
récupère les bouteilles. Assurez-vous que le nombre
correct de cylindres permettant de contenir la
charge totale du système est disponible. Tous les
cylindres à utiliser sont conçus pour le réfrigérant
récupéré et étiquetés pour ce réfrigérant, c’est-à-
dire des cylindres spéciaux pour la récupération
du réfrigérant. Les bouteilles doivent être équipées
d’une soupape de surpression et des vannes d’arrêt
associées en bon état de fonctionnement. Les
bouteilles de récupération vides sont évacuées et, si
possible, refroidies avant la récupération.
L’équipement de récupération doit être en bon état
de fonctionnement, avec un ensemble d’instructions
concernant l’équipement disponible et doit
être adapté à la récupération des réfrigérants
infl ammables. En outre, un jeu de balances
étalonnées doit être disponible et en bon état de
fonctionnement. Les fl exibles doivent être complets
avec des raccords débranchés sans fuite et en bon
état. Avant d’utiliser la machine de récupération,
vérifi ez qu’elle est en bon état de fonctionnement,
correctement entretenue et que tous les composants
électriques associés sont scellés pour éviter toute
infl ammation en cas de fuite du réfrigérant.
Consultez le fabricant en cas de doute.
Le fl uide frigorigène récupéré doit être renvoyé au
fournisseur de fl uide frigorigène dans la bouteille
de récupération appropriée et la note de transfert
de déchets correspondante doit être préparée. Ne
mélangez pas les réfrigérants dans les unités de
récupération et en particulier dans les bouteilles. Si
des compresseurs ou des huiles de compresseurs
doivent être éliminés, assurez-vous qu’ils ont été
évacués à un niveau acceptable pour vous assurer
que le réfrigérant infl ammable ne reste pas dans
le lubrifi ant. Le processus d’évacuation doit être
effectué avant de renvoyer le compresseur aux
fournisseurs. Seul un chauffage électrique du corps
du compresseur doit être utilisé pour accélérer
ce processus. Lorsque l’huile est vidangée d’un
système, elle doit être effectuée en toute sécurité.
22
INSTRUCTIONS D’INSTALLATION
23
OUTILS REQUIS
Tournevis: Phillips et tête plate.
Perceuse électrique: 3,2 mm (1/8 po.) de
diamètre
• Crayon
• Mètre ruban
• Les ciseaux
Niveau du charpentier
ACCESSOIRES
Les accessoires suivants sont inclus avec l’appareil et
doivent être utilisés pendant l’installation.
1. Vis de 13 mm (1/2 po) (x7)
2. Vis de 9,5 mm (3/8 pouce) (x4) (installées en
usine sur certains modèles).
3. Verrouillage de sécurité
4. Joint de mousse adhésif
5. Joint en mousse régulière
6. Support de montage en forme de «L» (installé en
usine sur certains modèles.)
7. Support pour fenêtres en bois (x2)
8. Support pour fenêtres en vinyle (x2)
9. Coupe-froid (x5)
10. Rideaux latéraux (x2)
EMPLACEMENT
Ce climatiseur est conçu pour les fenêtres simples ou
doubles. Étant donné que la conception des fenêtres
varie, il peut être nécessaire d’apporter certaines
modifi cations pour une installation en toute sécurité.
Ce climatiseur n’est pas conçu pour les fenêtres
verticales du type à glissière ni pour l’installation «à
travers le mur».
Assurez-vous que la fenêtre et le cadre sont
structurellement sains et exempts de bois sec ou
pourri.
Installez le climatiseur dans une fenêtre sur un côté
du bâtiment qui favorise plus d’ombre que de soleil.
Si l’appareil doit être à la lumière directe du soleil,
il est conseillé de prévoir un store pare-soleil pour
assurer un fonctionnement effi cace.
N’installez pas l’appareil si une fuite de gaz
combustible est suspectée.
Cet appareil est conçu pour évaporer la
condensation dans des conditions normales. Dans
des conditions extrêmement chaudes ou humides,
un excès de condensation peut déborder vers
l’extérieur. L’appareil doit être installé à un endroit
où la condensation ne peut pas goutter sur les
piétons ou les propriétés voisines.
Laissez un espace suffi sant autour de l’appareil
pour permettre une circulation d’air suf sante.
L’arrière de l’appareil doit être à l’extérieur, pas
dans un garage ni dans une autre pièce. Maintenez
l’appareil à l’écart des obstacles et à au moins 76
cm (30”) du sol. Assurez-vous que les rideaux et
autres obstructions ne bloquent pas le fl ux d’air vers
l’appareil.
76.2 cm
(30 pouces)
50.8 cm
(20 pouces)
50.8 cm
(20 pouces)
30.5 po
(12 cm)
1
2 3
4
5
6
9
8
7
10
INSTRUCTIONS D’INSTALLATION
24
L SUPPORT
Le support en forme de «L» peut être installé en
usine sur certains modèles.
Si le support en forme de «L» n’est pas préinstallé,
xez-le au haut de l’armoire comme indiqué ci-
dessous à l’aide des vis fournies de 9,5 mm (3/8”)
(x4).
INSTALLATION
Fixez les rideaux latéraux à l’appareil en faisant
glisser le cadre du rideau dans le canal latéral
de l’armoire. Les rideaux sont étiquetés «gauche»
et «droite sur les cadres. Cela concerne les côtés
gauche et droit de l’appareil lorsque vous faites
face à l’avant de l’appareil.
Coupez le joint en mousse ordinaire pour qu’il
corresponde à la zone du rebord de la fenêtre sur
laquelle le climatiseur reposera.
Placez le climatiseur dans la fenêtre avec le support
de montage en forme de «L» placé devant le châssis
supérieur. Le bas de l’armoire doit être placé sur la
partie en retrait du cadre de la fenêtre. Abaisser
le châssis de la fenêtre supérieure jusqu’à ce qu’il
repose juste derrière la bride avant du support de
montage en forme de «L».
Développez les rideaux latéraux de chaque côté
et fi xez le haut des cadres au châssis de fenêtre à
l’aide d’une vis de 13 mm (1/2”) de chaque côté
du support de montage en forme de“ L ”.
Fixez les fi xations situées sur la partie inférieure
de chaque rideau au rebord de la fenêtre à l’aide
d’une vis de 13 mm (1/2”) de chaque côté du
meuble.
Placez le joint en mousse adhésif dans l’ouverture
entre les fenêtres intérieure et extérieure et fi xez le
verrou de sécurité sur le cadre de fenêtre extérieur à
l’aide de deux vis de 13 mm (1/2”).
A
Vérifi ez l’angle d’inclinaison
Le climatiseur doit être incliné vers le bas vers
l’extérieur environ 3° à 4°. Cette inclinaison
encouragera toute eau condensée à s’écouler vers
l’extérieur. Si de l’eau condensée fuit à l’intérieur de
la maison, vérifi er l’angle d’inclinaison et ajuster si
nécessaire.
Mesurez l’angle d’inclinaison de l’avant du bord
de l’armoire. La différence de hauteur entre l’avant
et l’arrière de l’appareil, étiqueté “A” sur l’image
ci-dessous, devrait être d’environ 19 mm - 2,5 cm
(3/4” - 1”).
PANNEAU DE CONTRÔLE
1. Récepteur de télécommande: Assurez-vous que ce récepteur n’est pas obscurci par des rideaux ou
d’autres éléments, car cela pourrait avoir un impact sur le fonctionnement de la télécommande.
2. Suivez-moi voyant: S’allume lorsque la fonction suivez-moi est activée. Suivez-moi ne peut être réglé
qu’à partir de la télécommande.
3. Bouton d’alimentation: Utilisé pour allumer ou éteindre l’appareil.
4. Bouton mode: Utilisé pour choisir le mode de fonctionnement.
5. Flèches haut et bas: Utilisé pour ajuster la température réglée par incréments de 1° et la fonction de
minuterie en des incréments de 30 minutes jusqu’à 10 heures, puis en incréments de 1 heure jusqu’à
24 heures.
6. Panneau d’af chage: Af che la température réglée, la température ambiante et les réglages de la
minuterie. Pour changer l’échelle de température affi chée, appuyez simultanément sur les boutons haut
et bas.
7. Bouton ventilateur: Utilisé pour régler la vitesse du ventilateur. Le ventilateur peut être réglé sur Bas,
Moyen, Haut et Auto.
8. Bouton de connexion sans fi l: Utilisé pour se connecter à un réseau sans fi l.
9. Bouton d’économie d’énergie: Utilisé pour défi nir la fonction économiseur d’énergie.
10. Bouton ltre: Le témoin lumineux s’allume comme un rappel pour vérifi er le fi ltre. Une fois que le fi ltre a
été nettoyé, utilisez ce bouton pour reprendre son fonctionnement.
11. Bouton de sommeil: Utilisé pour régler la fonction sommeil.
12. Bouton de minuterie: Utilisé pour régler la minuterie de marche et arrêt automatique.
1
2
3
4 5
6
7
8
9
10
11 12
25
INSTRUCTIONS D’UTILISATION
INSTRUCTIONS D’UTILISATION
26
TEMP
1
2
3
4
5
6
7
8
9
10
11
12
13
TÉLÉCOMMANDE
1. Panneau d’af chage: Af che la température
défi nie, la température ambiante et les réglages
de la minuterie. Pour changer l’échelle de
température affi chée, appuyez sur la touche
°C/°F.
2. Flèches haut et bas: Utilisé pour ajuster la
température réglée par incréments de 1° et la
fonction de minuterie en des incréments de 30
minutes jusqu’à 10 heures, puis en incréments
de 1 heure jusqu’à 24 heures.
3. Bouton mode: Utilisé pour choisir le mode de
fonctionnement.
4. Bouton de suivez-moi: Utilisé pour défi nir la
fonction suivez-moi.
5. Bouton °C/°F: Utilisez pour changer l’échelle de
température.
6. Bouton LED: Appuyez sur pour allumer ou
éteindre le rétro-éclairage de la LED.
7. Bouton d’alimentation: Utilisé pour allumer ou
éteindre l’appareil.
8. Bouton de dormir: Utilisé pour régler la fonction
dormir.
9. Bouton ventilateur: Utilisé pour régler la vitesse
du ventilateur. Le ventilateur peut être réglé sur
bas, moyen, haut et auto.
10. Bouton minuterie d’allumer: Utilisé pour régler
la minuterie d’allumer.
11. Bouton minuterie d’éteindre: Utilisé pour régler
la minuterie d’éteindre automatique.
12. Bouton d’économie d’énergie: Utilisé pour
défi nir la fonction économiseur d’énergie.
13. Bouton de verrouillage: Appuyez simultanément
sur les touches °C/°F et la minuterie pour
verrouiller la télécommande et éviter que les
réglages ne soient modifi és par inadvertance.
27
INSTRUCTIONS D’UTILISATION
PILES DE LA TÉLÉCOMMANDE
La télécommande nécessite deux piles alcalines
AAA (incluses). Les piles doivent être remplacées
lorsque:
a) Aucun son n’est entendu lors de la tentative de
programmation de l’appareil.
b) L’appareil ne répond pas à une commande émise
par la télécommande.
Remplacement de la batterie:
1. Faites glisser le capot arrière sur la
télécommande dans le sens de la fl èche.
2. Insérez deux piles AAA suivant la même
orientation représentée à l’intérieur de la
chambre de la batterie (+/-).
3. Réinstallez le capot arrière.
4. Si la télécommande n’est pas utilisée pendant de
longues périodes, les piles doivent être retirées.
Remarques:
Protégez la télécommande contre les
températures élevées et évitez l’exposition au
rayonnement.
Gardez le récepteur du panneau de contrôle
hors de la lumière directe du soleil.
Ne mélangez pas les piles neuves et neuves.
Ne pas mélanger des piles alcalines, standard
(carbone-zinc) ou rechargeables (ni-cad, ni-mh,
etc.).
La télécommande fonctionne à une distance de
8 mètres (26 pi) du récepteur situé à l’intérieur
de l’appareil principal. Toute obstruction entre
le récepteur et la télécommande peut provoquer
des interférences de signal, ce qui limite la
capacité de programmer l’unité principale.
MODES DE FONCTIONNEMENT
Vous avez le choix entre quatre modes de
fonctionnement. Appuyez plusieurs fois sur le
bouton de mode pour choisir le mode souhaité. Le
voyant adjacent s’allume pour indiquer quel mode a
été sélectionné.
Mode de refroidissement
Choisissez le mode refroidissement pour défi nir la
fonction de refroidissement. Utilisez les fl èches haut
et bas pour choisir la température désirée. Lorsque
le mode de refroidissement est sélectionné, la vitesse
du ventilateur peut être ajustée en appuyant sur le
bouton du ventilateur.
• Mode sec
Choisissez le mode sec pour éliminer l’excès
d’humidité de l’air pendant les périodes de forte
humidité. Toute l’eau extraite de l’air se condensera
à l’intérieur de l’appareil et s’écoulera par l’arrière.
La vitesse du ventilateur sera automatiquement
réglée et ne pourra pas être modifi ée en mode sec.
• Mode ventilateur
Choisissez le mode ventilateur pour faire
fonctionner le ventilateur interne sans activer la
fonction de refroidissement. Appuyez plusieurs fois
sur le bouton du ventilateur pour choisir la vitesse
du ventilateur.
• Mode automatique
Le mode automatique est un programme d’usine
prédéfi ni qui défi nit automatiquement le mode et la
vitesse du ventilateur en fonction de la température
défi nie, de la température ambiante et de l’humidité
ambiante.
FLÈCHES HAUT ET BAS
Les fl èches haut et bas modifi eront la température
de consigne par incréments de 1°.
Les fl èches haut et bas modifi eront l’heure réglée
de la fonction de minuterie par incréments de 0,5
heure jusqu’à 10 heures, puis par incréments d’une
heure jusqu’à 24 heures maximum.
28
INSTRUCTIONS D’UTILISATION
DORMIR
La fonction de dormir peut être utilisée pour
économiser de l’énergie pendant les heures de
dormir.
Lorsque cette option est sélectionnée, la température
défi nie augmente de 1°C/2°F toutes les demi-
heures pendant une heure complète. L’appareil
maintiendra la nouvelle température réglée pendant
6 heures avant de revenir automatiquement au
fonctionnement normal.
La fonction de dormir peut être annulée à tout
moment en appuyant sur le bouton de dormir.
ÉCONOMIE D’ÉNERGIE
La fonction d’économie d’énergie activera et
désactivera automatiquement le ventilateur lorsque
le compresseur ne sera pas utilisé afi n de minimiser
la fréquence à laquelle le compresseur doit
s’allumer.
Lorsque sélectionné, le ventilateur continuera à
fonctionner pendant 3 minutes après la mise hors
tension du compresseur. Le ventilateur se met ensuite
en marche pendant 2 minutes, par intervalles
de 10 minutes, jusqu’à ce que la température
ambiante soit supérieure à la température défi nie.
Le compresseur se met alors en marche et le
refroidissement reprend.
SUIVEZ-MOI
Un capteur de température intégré à la
télécommande surveille la température ambiante.
Gardez la télécommande avec vous et l’appareil
ajustera automatiquement la température de
consigne en fonction de la température où vous
vous trouvez.
La télécommande affi chera la température à son
emplacement. La télécommande envoie un signal au
climatiseur toutes les 3 minutes, tant que vous restez
à portée de l’appareil.
Le voyant Follow me du panneau de commande
s’allumera pendant 5 secondes toutes les 3
minutes pour indiquer qu’il a reçu un signal de
la télécommande. Si l’appareil ne reçoit pas de
signal de la télécommande pendant un intervalle
de 7 minutes, il émettra un bip pour indiquer que le
mode suivez-moi est terminé.
La distance maximale pour la fonction suivez-moi
est de 8 mètres (26 pieds). Cette fonctionnalité est
disponible en modes cool et auto.
CONNEXION SANS FIL
Cet appareil peut être contrôlé avec une application
sans fi l sur votre appareil sans fi l.
Rendez-vous sur https://www.danby.com/
support/#apps pour télécharger l’application et
découvrir son fonctionnement.
INSTRUCTIONS D’UTILISATION
29
MINUTERIE
La minuterie peut être utilisée pour allumer ou
éteindre l’appareil après une période de temps
défi nie.
Le panneau de commande a un bouton de
minuterie. Appuyez une fois sur cette touche pour
régler la minuterie d’extinction automatique et
deux fois sur cette touche. La télécommande a des
boutons de minuterie activés et désactivés.
Fonction allumer automatique
1. Appuyez sur la touche minuterie de la
télécommande ou appuyez deux fois sur la
touche timer du panneau de commande.
2. Utilisez les fl èches vers le haut et vers le bas
pour sélectionner la durée souhaitée avant la
mise en marche de l’appareil.
3. Utilisez le bouton de mode pour sélectionner le
mode souhaité.
4. Utilisez le bouton du ventilateur pour
sélectionner la vitesse du ventilateur souhaitée.
5. La durée sélectionnée apparaîtra sur l’écran et
comptera jusqu’à ce que l’appareil s’allume.
Minuterie d’éteindre automatique
1. Appuyez sur le bouton de minuterie de la
télécommande ou appuyez une fois sur
le bouton de la minuterie du panneau de
commande.
2. Utilisez les fl èches vers le haut et vers le
bas pour sélectionner la durée souhaitée
avant l’extinction de l’appareil. L’appliance
fonctionnera dans le mode actuellement
sélectionné.
3. La durée sélectionnée apparaîtra sur l’écran et
comptera jusqu’à ce que l’appareil s’éteigne.
Utilisation simultanée de minuteries allumer
et éteindre
Les minuteries d’allumer et d’éteindre peuvent être
utilisées en même temps.
Pour que l’appareil s’allume, lancez-le pendant
une durée défi nie, puis éteignez-le, confi gurez
d’abord la minuterie d’activation automatique, puis
défi nissez la minuterie d’extinction automatique.
Pour que l’appareil fonctionne pendant une certaine
période, éteignez-le puis rallumez-le, confi gurez
d’abord la minuterie d’éteindre automatique, puis la
minuterie d’allume automatique.
Les deux voyants s’allumeront et l’affi chage
indiquera jusqu’à ce que l’appareil s’éteigne ou
s’allume, selon la fonction défi nie en premier.
La minuterie ne fera pas allumer et éteindre
l’appareil indéfi niment. Les minuteries d’allumage et
d’extinction fonctionneront une fois, puis l’appareil
retournera à son fonctionnement normal.
Le fait d’éteindre ou de débrancher l’appareil efface
tous les paramètres de la mémoire, y compris la
minuterie.
30
SOINS ET ENTRETIEN
FILTRE À AIR
Le fi ltre à air doit être nettoyé environ toutes les 2
semaines. Le fi ltre à air peut nécessiter un nettoyage
plus fréquent si il y a un choc important ou de la
fourrure dans l’air.
Environ toutes les deux semaines, le voyant du
ltre sur le panneau de commande s’allume pour
rappeler le nettoyage du fi ltre. Suivez les étapes ci-
dessous pour nettoyer le fi ltre et retournez l’appareil
au fonctionnement normal.
1. Le ltre à air est situé derrière la grille
d’admission avant. Pour retirer le fi ltre à air,
saisissez la languette du fi ltre sur le côté droit
de la grille et glissez-la vers la droite. Si la grille
d’admission avant comporte deux retraits, tirez
la grille vers l’avant pour retirer le fi ltre à air.
2. Utilisez un aspirateur avec une brosse douce
pour enlever les grands débris ou la poussière
du fi ltre à air.
3. Laver le fi ltre dans de l’eau tiède savonneuse,
inférieure à 40°C (104°F), ou utiliser un agent
de nettoyage neutre.
4. Rincez le fi ltre avec de l’eau propre et séchez
bien avant de le réinstaller dans l’appareil.
5. Appuyez sur le bouton de fi ltre sur le panneau
de commande pour reprendre le fonctionnement
normal.
Remarque: Ne pas utiliser l’appareil sans le fi ltre à
air installé.
CODES D’ERREUR
Si le panneau d’affi chage af che l’un des codes
d’erreur ci-dessous, débranchez l’appareil, laissez
reposer pendant 5 à 10 minutes, puis rallumez-le.
Si l’erreur persiste, appelez le service.
AS - Erreur du capteur de température ambiante
HI - Erreur du capteur de température
LO - Erreur du capteur de température
. - Erreur du capteur de température de
l’évaporateur
NETTOYAGE
Pour éviter tout risque d’électrocution, assurez-vous
que l’appareil est débranché avant d’effectuer un
nettoyage ou une maintenance.
L’extérieur de l’appareil peut être nettoyé avec un
chiffon doux ou avec un chiffon tiède et humide si
nécessaire.
N’utilisez pas d’essence, de benzène, de diluant
ou de tout autre produit chimique pour nettoyer cet
appareil car ces substances peuvent endommager
la fi nition et la déformation des pièces en plastique.
Ne versez jamais d’eau directement sur l’appareil,
car cela entraînera une détérioration des
composants électriques et de l’isolation des câbles.
SOINS POUR LA FIN DE SAISON
Avant de retirer l’appareil du service pour l’année,
faites fonctionner l’appareil sur le mode ventilateur
élevé pendant une demi-journée pour vous assurer
que l’intérieur de l’appareil est sec. Cela aidera
à éviter la croissance de la moisissure ou de la
moisissure à l’intérieur de l’appareil. Assurez-vous
que le fi ltre est propre et sec. Rangez l’appareil
dans un endroit sec.
Remarque: Lors de l’installation ou de l’enlèvement
de l’appareil de la fenêtre, veillez à ce qu’il soit
prudent de l’empêcher de tomber vers l’arrière. Il
est recommandé que l’installation ou l’enlèvement
soit complété avec une assistance pour éviter les
blessures aux personnes ou les dommages matériels
ou l’appareil.
DISPOSITION
Vérifi ez la conformité réglementaire locale
concernant l’élimination approuvée et sûre de cet
appareil.
DÉPANNAGE
PROBLÈME CAUSE POSSIBLE
L’appareil ne fonctionnera pas • La che n’est pas complètement insérée dans la prise murale
Fusible souffl é ou disjoncteur
Refroidissement insuffi sant • Le ltre à air est sale
Flux d’air bloqué
La taille de l’appareil est trop petite pour l’application
Bruit Support inadéquat dans l’installation de fenêtre
Les odeurs Formation de moisissure sur des surfaces intérieures humides
Placer un comprimé d’algaïcide dans un moule de base; poussez
la tablette à travers la grille de chaque côté de l’appareil
L’eau s’écoule à l’intérieur L’appareil n’est pas correctement incliné pour permettre à l’eau
de s’écouler vers l’extérieur
Eau dégouttant à l’extérieur Sur des jours très chauds ou humides, l’eau qui goutte à l’arrière
de l’appareil est normale
Accumulation de givre Lorsque les températures extérieures sont inférieures à 18,3°C
(65°F), une gelée peut se former lorsque l’appareil est en mode
refroidissement
Mettez l’appareil en mode ventilateur seulement jusqu’à ce que
le givre fond
31
Danby soins du consommateur : 1-800-263-2629 ou consumerservice@danby.com
Heures d’ouverture :
Du lundi au jeudi, de 8 h 30 à 18 h, heure de l’Est
Vendredi, de 8 h 30 à 16 h, heure de l’Est
Les informations contenues dans ce manuel sont sujettes à modifi cation sans préavis.
Cet appareil numérique de classe B est conforme à
la norme Canadienne ICES-003. CAN ICES-3 (B)
Cet équipement a été testé et s’est avéré conforme
aux limites d’un appareil numérique de classe B,
conformément à la partie 15 des règles de la FCC.
Ces limites sont conçues pour fournir une protection
raisonnable contre les interférences dans une
installation résidentielle.
Cet équipement génère, utilise et peut émettre
de l’énergie radiofréquence et, s’il n’est pas
installé et utilisé conformément aux instructions,
peut provoquer des interférences dans les
communications radio. Cependant, il n’y a aucune
garantie que des interférences ne se produiront pas
dans une installation particulière.
Si cet équipement cause des interférences à la
réception de la radio ou de la télévision, ce qui peut
être déterminé en allumant et éteindre l’équipement,
l’utilisateur est encouragé à essayer de corriger
les interférences en prenant une ou plusieurs des
mesures suivantes:
1. Réorientez ou déménagez l’antenne de
réception.
2. Augmenter la séparation entre l’équipement et le
récepteur.
3. Connectez l’équipement à une prise de courant
sur un circuit différent de celui auquel le
récepteur est connecté.
4. Consultez le revendeur ou un technicien
expérimenté en radio / télévision pour obtenir
de l’aide.
Les modifi cations ou modifi cations non approuvées
par la partie responsable de la conformité de la
FCC peuvent annuler l’autorisation de l’utilisateur
d’utiliser l’équipement.
Cet appareil est conforme à la partie 15 des règles
de la FCC.
L’opération est soumise aux deux conditions
suivantes:
1. Cet appareil ne doit pas provoquer
d’interférence.
2. Cet appareil doit accepter toute interférence
reçue, y compris les interférences pouvant
entraîner un fonctionnement indésirable.
LIMITED IN-HOME APPLIANCE WARRANTY
This quality product is warranted to be free from manufacturer’s defects in material and workmanship, provided that the unit is used under the normal operating
conditions intended by the manufacturer.
This warranty is available only to the person to whom the unit was originally sold by Danby Products Limited (Canada) or Danby Products Inc. (U.S.A.) (hereafter
“Danby”) or by an authorized distributor of Danby, and is non-transferable.
TERMS OF WARRANTY
Plastic parts, are warranted for thirty (30) days only from purchase date, with no extensions provided.
First Year
During the rst twelve (12) months, any functional parts of this product found to be defective, will be repaired or replaced, at warrantor’s
option, at no charge to the ORIGINAL purchaser.
To obtain
Danby reserves the right to limit the boundaries of “In Home Service” to the proximity of an Authorized Service Depot. Any app liance
Service
requiring service outside the limited boundaries of “In Home Service” , it will be the consumer’s responsibility to transport the appliance (at
their own expense) to the original retailer (point of purchase) or a service depot for repair. See “Boundaries of In Home Serv ice” below.
Contact your dealer from whom your unit was purchased, or contact your nearest authorized Danby service depot, where service
must be performed by a qualied service technician.
If service is performed on the units by anyone other than an authorized service depot, or the unit is used for commercial appli cation, all
obligations of Danby under this warranty shall be void.
Boundaries of
If the appliance is installed in a location that is 100 kilometers (62 miles) or more from the nearest service center your unit must be
In Home Service
delivered to the nearest authorized Danby Service Depot, as service must only be performed by a technician qualied and certif ied for
warranty service by Danby. Transportation charges to and from the service location are not protected by this warranty and are t he
responsibility of the purchaser.
Nothing within this warranty shall imply that Danby will be responsible or liable for any spoilage or damage to food or other c ontents of this appliance, whether due
to any defect of the appliance, or its use, whether proper or improper.
EXCLUSIONS
Save as herein provided, Danby, there are no other warranties, conditions, representations or guarantees, express or implied, m ade or intended by Danby or its
authorized distributors and all other warranties, conditions, representations or guarantees, including any warranties, conditio ns, representations or guarantees
under any Sale of Goods Act or like legislation or statue is hereby expressly excluded. Save as herein provided, Danby shall no t be responsible for any damages
to persons or property, including the unit itself, howsoever caused or any consequential damages arising from the malfunction o f the unit and by the purchase of
the unit, the purchaser does hereby agree to indemnify and hold harmless Danby from any claim for damages to persons or propert y caused by the unit.
GENERAL PROVISIONS
No warranty or insurance herein contained or set out shall apply when damage or repair is caused by any of the following:
1) Power failure.
2) Damage in transit or when moving the appliance.
3) Improper power supply such as low voltage, defective house wiring or inadequate fuses.
4) Accident, alteration, abuse or misuse of the appliance such as inadequate air circulation in the room or abnormal operating con ditions
(extremely high or low room temperature).
5) Use for commercial or industrial purposes (ie. If the appliance is not installed in a domestic residence).
6) Fire, water damage, theft, war, riot, hostility, acts of God such as hurricanes, oods etc.
7) Service calls resulting in customer education.
8) Improper Installation (ie. Building-in of a free standing appliance or using an appliance outdoors that is not approved for out door application).
Proof of purchase date will be required for warranty claims; so, please retain bills of sale. In the event warranty service is required, present this document to our
AUTHORIZED SERVICE DEPOT.
Danby Products Limited
PO Box 1778, Guelph, Ontario, Canada N1H 6Z9
Telephone: (519) 837-0920 FAX: (519) 837-0449
Danby Products Inc.
PO Box 669, Findlay, Ohio, U.S.A. 45840
Telephone: (419) 425-8627 FAX: (419) 425-8629
04/09
1-800-263-2629
Warranty Service
In-home
Les frais de transport entre votre domicile et le lieu de l'entretien ne sont pas couverts par la présente garantie et doivent être
acquittés par l'acheteur.
Pendant les premiers vingt quatre (24) mois, toutes les pièces fonctionnelles de ce produit qui s’avèrent
défectueuses seront réparées ou remplacées, selon le choix du garant, sans frais à l’acheteur initial.
Contactez le revendeur où l'appareil a été acheté ou contactez le dépôt de service Danby autorisé le plus
proche, où le service doit être effectué par un technicien de service qualifié. Si le service est effectué sur
l'appareil par une personne autre qu'un dépôt de service autorisé, toutes les obligations de Danby en vertu de
cette garantie seront annulées.
Il est de la responsabilité de l'acheteur de transporter l'appareil vers le dépôt de service agréé le plus proche.
Premiers 24 mois
Pour obtenir un
service
GARANTIE LIMITÉE « EN ATELIER »
Cet appareil de qualité est garanti exempt de tout vice de matière première et de fabrication, s’il est utilisé dans les conditions normales
recommandées par le fabricant.
Cette garantie n’est offerte qu’à l’acheteur initial de l’appareil vendu par Danby Products Limited (Canada) ou Danby Products Inc.
(É.-U.) (ci-après « Danby ») ou par l’un des ses distributeurs agréés et elle ne peut être transférée.
CONDITIONS
Les pièces en plastique sont garanties pendant trente (30) jours seulement à partir de la date de l’achat, sans aucune prolongation
prévue.
Service sous garantie
En Atelier
Danby Products Limited
PO Box 1778, Guelph, Ontario, Canada N1H 6Z9
Téléphone : (519) 837-0920 Télécopieur : (519) 837-0449
Danby Products Inc.
PO Box 669, Findlay, Ohio, U.S.A. 45840
Téléphone : (419) 425-8627 Télécopieur : (419) 425-8629
1-800-263-2629
02/18
Aucune partie de la garantie ne prévoit implicitement que le fabricant sera tenu responsable des dommages subis par les aliments ou
d’autres types de contenu, qu’ils soient causés par la défectuosité de l’appareil ou par son usage adéquat ou inadéquat.
EXCLUSIONS
En vertu de la présente, il n’existe aucune autre garantie, condition ou représentation, qu’elle soit exprimée ou tacite, de façon
manifeste ou intentionnelle, par Danby ou ses distributeurs agréés. De même, sont exclues toutes les autres garanties, conditions ou
représentations, y compris les garanties, conditions ou représentations en vertu de toute loi régissant la vente de produits ou de toute
autre législation ou règlement semblable. En vertu de la présente, Danby ne peut être tenue responsable en cas de blessures
corporelles ou de dégâts matériels, y compris à l’appareil, quelle qu’en soit les causes. Danby ne peut pas être tenue responsable
des dommages indirects dus au fonctionnement défectueux de l’appareil. En achetant l’appareil, l’acheteur accepte de tenir sans
reproche et de dégager Danby de toute responsabilité en cas de réclamation pour toute blessure corporelle ou tout dégât matériel
causé par cet appareil.
CONDITIONS GÉNÉRALES
La garantie ou assurance ci-dessus ne s’applique pas si les dégâts ou réparations sont dus aux cas suivants :
1) Panne de courant.
2) Dommages subis pendant le transport ou le déplacement de l’appareil.
3) Alimentation électrique incorrecte (tension faible, câblage défectueux, fusibles incorrects).
4) Accident, modification, emploi abusif ou incorrect de l’appareil tel qu'une circulation d'air inadéquate dans la pièce ou des
conditions de fonctionnement anormales (température extrêmement élevée ou basse).
5) Utilisation dans un but commercial ou industriel (à savoir, si l'appareil n'est pas installé dans un domicile résidentiel).
6) Incendie, dommages causés par l’eau, le vol, la guerre, une émeute, des hostilités, ou en cas de force majeure (ouragan,
inondation, etc.).
7) Visites d’un technicien pour expliquer le fonctionnement de l’appareil au propriétaire.
8) Installation inappropriée (par exemple, encastrement d'un appareil autoportant, ou utilisation extérieure d'un appareil non conçu à
cet effet, y compris, mais sans s'y limiter : les garages, les patios, les porches ou ailleurs, qui ne sont pas correctement isolés ou
climatisés).
La preuve de la date d'achat sera requise pour les réclamations de garantie; conserver la facture de vente. Dans le cas où un service
de garantie est requis, présentez la preuve d'achat à notre dépôt de service agréé.
33
1-800-26- Danby
(1-800-263-2629)
Bienvenido
Bienvenido a la familia Danby. Estamos orgullosos de nuestros productos de calidad y creemos en
un servicio confi able. Sugerimos que lea este manual del propietario antes de conectar el nuevo
aparato ya que contiene información importante sobre la operación, información de seguridad,
solución de problemas y consejos de mantenimiento para garantizar la fi abilidad y longevidad de
su electrodoméstico.
Visite www.Danby.com para acceder a herramientas de autoservicio, preguntas frecuentes y
mucho más. Para asistencia adicional, llame al 1-800-263-2629.
Tenga en cuenta la información siguiente; Necesitará esta información para obtener un servicio
bajo garantía.
Debe proporcionar el recibo de compra original para validar su garantía y recibir servicio.
Número de modelo: _____________________________________________
Número de serie: _______________________________________________
Fecha de compra: _______________________________________________
Necesitas ayuda?
Antes de llamar al servicio, aquí hay algunas cosas que puede hacer para ayudarnos a
servirle mejor.
Lea este manual del propietario:
Contiene instrucciones para ayudarle a usar y mantener su aparato correctamente.
Si recibe un aparato dañado:
Inmediatamente póngase en contacto con el minorista o el constructor que le vendió el
aparato.
Ahorre tiempo y dinero:
Consulte la sección de solución de problemas al fi nal de este manual antes de llamar. Esta
sección le ayudará a resolver problemas comunes que pueden ocurrir.
34
¡GUARDE ESTAS INSTRUCCIONES!
PRECAUCIÓN: RIESGO DE INCENDIO
Refrigerante infl amable utilizado. Al mantener o
desechar el acondicionador de aire, no se debe
permitir que el refrigerante se ventile al aire libre.
INSTRUCCIONES DE CONEXION A TIERRA
Este aparato debe estar conectado a tierra. La
puesta a tierra reduce el riesgo de descarga
eléctrica proporcionando un cable de escape para
la corriente eléctrica.
Este aparato tiene un cable que tiene un cable de
conexión a tierra con un enchufe de 3 clavijas. El
cable de alimentación debe estar enchufado en un
tomacorriente que esté debidamente conectado a
tierra. Si el tomacorriente es un enchufe de pared
de 2 terminales, debe ser reemplazado por un
tomacorriente de pared de 3 clavijas debidamente
conectado a tierra. La placa de características en
serie indica el voltaje y la frecuencia que el aparato
está diseñado para.
ADVERTENCIA - El uso incorrecto del enchufe
de conexión a tierra puede resultar en un riesgo
de descarga eléctrica. Consulte a un electricista
califi cado o agente de servicio si las instrucciones
de conexión a tierra no se entienden completamente
o si existe duda sobre si el aparato está
debidamente conectado a tierra.
No conecte el aparato a los cables de extensión ni
con otro aparato en la misma toma de corriente.
No empalme el cable de alimentación. No corte ni
extraiga en ningún caso la tercera clavija de tierra
del cable de alimentación. No utilice cables de
extensión ni adaptadores sin conexión a tierra (dos
clavijas).
Si el cable de alimentación está dañado, debe
ser reemplazado por el fabricante, su agente de
servicio o persona califi cada similar para evitar
riesgos.
Importantes Instrucciones de Seguridad
LEA Y SIGA TODAS LAS INSTRUCCIONES DE SEGURIDAD
REQUERIMIENTOS DE SEGURIDAD
PELIGRO: Riesgo de incendio o explosión.
Refrigerante infl amable utilizado. No dañe el
circuito de refrigerante.
Asegúrese de que el servicio sea realizado por
personal de servicio autorizado de fábrica,
para minimizar los daños del producto o los
problemas de seguridad.
Consulte el manual de reparación o la guía
del propietario antes de intentar reparar
este producto. Deben seguirse todas las
precauciones de seguridad.
Deséchese adecuadamente de acuerdo con las
regulaciones federales o locales.
Siga cuidadosamente las instrucciones de
manejo.
Mantenga las aberturas de ventilación, en el
aparato, sin obstrucciones.
No utilice dispositivos mecánicos u otros medios
para acelerar el proceso de descongelación.
Los niños deben ser supervisados para
asegurarse de que no jueguen con el aparato.
No almacene ni instale el aparato cerca
de fuentes de ignición que funcionen
continuamente, como llamas o una estufa de
gas.
No operar cerca del agua o en una habitación
húmeda.
No perforar o quemar.
Tenga en cuenta que los refrigerantes no pueden
contener un olor.
El aparato debe almacenarse para evitar daños
mecánicos.
Todo el cableado debe cumplir con los códigos
locales y nacionales y debe ser instalado por
un electricista califi cado. Verifi que la fuente de
alimentación disponible y resuelva cualquier
problema de cableado antes de instalar y operar
este dispositivo.
La placa de características ubicada en el lado
derecho del aparato, justo encima del cable de
alimentación, contiene datos eléctricos y otros datos
técnicos.
Este dispositivo no está destinado a ser utilizado
por personas (incluidos niños) cuyas capacidades
físicas, sensoriales o mentales pueden ser diferentes
o reducidas, o que carecen de experiencia o
conocimiento, a menos que dichas personas
sean supervisadas o entrenadas para operar el
dispositivo por una persona responsable de su la
seguridad.
Importantes Instrucciones de Seguridad
LEA Y SIGA TODAS LAS INSTRUCCIONES DE SEGURIDAD
Cualquier persona involucrada en trabajar en el
circuito de refrigerante debe tener un certifi cado
válido y vigente de una autoridad de evaluación
acreditada de la industria que autorice su
competencia para manejar refrigerantes de manera
segura de acuerdo con una especifi cación de
evaluación reconocida por la industria.
La reparación solo se realizará según lo
recomendado por el fabricante. El mantenimiento
y las reparaciones que requieran la asistencia de
otro personal califi cado deben realizarse bajo la
supervisión de la persona competente en el uso de
refrigerantes infl amables.
Al mantener o desechar el aparato, el refrigerante
debe recuperarse adecuadamente y no debe
permitirse que se descargue al aire directamente.
Información sobre mantenimiento
1. Cheques a la zona: Antes de comenzar
a trabajar en sistemas que contengan
refrigerantes infl amables, se necesitan controles
de seguridad para garantizar que se minimice
el riesgo de ignición. Para la reparación del
sistema de refrigeración, se deben cumplir
las siguientes precauciones antes de realizar
trabajos en el sistema.
2. Procedimiento de trabajo: El trabajo debe
realizarse bajo un procedimiento controlado
para minimizar el riesgo de que haya un gas o
vapor infl amable mientras se realiza el trabajo.
3. Área de trabajo general: Todo el personal de
mantenimiento y otras personas que trabajan en
el área local deben recibir instrucciones sobre
la naturaleza del trabajo que se está llevando
a cabo. Se evitará el trabajo en espacios
confi nados. El área alrededor del espacio de
trabajo debe ser seccionado. Asegúrese de
que las condiciones dentro del área de trabajo
se hayan hecho seguras eliminando todo el
material infl amable.
4. Comprobando la presencia de refrigerante: Se
deben verifi car con un detector de refrigerante
adecuado antes y durante el trabajo para
garantizar que el técnico tenga conocimiento
de las atmósferas potencialmente infl amables.
Asegúrese de que el equipo de detección de
fugas que se está utilizando sea adecuado
para el uso con refrigerantes infl amables, es
decir, que no produzcan chispas, que estén
adecuadamente sellados y sean intrínsecamente
seguros.
5. Presencia de extintor de incendios: Si se debe
realizar algún trabajo en caliente en el equipo
de refrigeración o en cualquier pieza asociada,
debe estar disponible el equipo de extinción de
incendios adecuado. Tenga un extintor de polvo
seco o C02 adyacente al área de trabajo.
6. No hay fuentes de ignición: Ninguna persona
que realice trabajos en relación con un sistema
de refrigeración que implique exponer cualquier
tubería que contenga o haya contenido
refrigerante infl amable deberá utilizar ninguna
fuente de ignición de tal manera que pueda
provocar riesgo de incendio o explosión. Todas
las fuentes de ignición posibles, incluido el
consumo de cigarrillos, deben mantenerse lo
sufi cientemente lejos del lugar de instalación,
reparación, eliminación y eliminación durante
los cuales es posible que se libere refrigerante
infl amable al espacio circundante. Antes de
realizar el trabajo, se debe inspeccionar el
área alrededor del equipo para asegurarse de
que no haya peligros infl amables o riesgos de
ignición. No se mostrarán señales de fumar.
7. Zona ventilada: Asegúrese de que el área
esté al aire libre o de que esté adecuadamente
ventilada antes de entrar en el sistema o
realizar cualquier trabajo en caliente. Un cierto
grado de ventilación deberá continuar durante
el período de trabajo. La ventilación debe
dispersar de forma segura cualquier refrigerante
liberado y, preferiblemente, expulsarlo
externamente a la atmósfera.
8. Comprobaciones al equipo de refrigeración:
Donde se cambien los componentes eléctricos,
deben ser adecuados para el propósito y para
la especifi cación correcta. En todo momento se
seguirán las pautas de mantenimiento y servicio
del fabricante. En caso de duda, consulte al
departamento técnico del fabricante para
obtener ayuda.
35
Importantes Instrucciones de Seguridad
LEA Y SIGA TODAS LAS INSTRUCCIONES DE SEGURIDAD
Se aplicarán los siguientes controles a las
instalaciones que utilizan refrigerantes infl amables:
El tamaño de carga está de acuerdo con el
tamaño de la habitación dentro de la cual se
instalan las piezas que contienen refrigerante.
La maquinaria de ventilación y las salidas
funcionan adecuadamente y no están
obstruidas.
Si se está utilizando un circuito de refrigeración
indirecto, se debe revisar el circuito secundario
para detectar la presencia de refrigerante.
El marcado al equipo sigue siendo visible y
legible. Las marcas y signos que se vuelven
ilegibles deben ser corregidos.
La tubería o los componentes de refrigeración
se instalan en una posición en la que es
poco probable que estén expuestos a alguna
sustancia que pueda corroer los componentes
que contienen refrigerante, a menos que
los componentes estén construidos con
materiales que sean inherentemente resistentes
a la corrosión o que estén protegidos
adecuadamente contra la corrosión.
9. Cheques a dispositivos eléctricos: La reparación
y el mantenimiento de los componentes
eléctricos deben incluir controles de seguridad
iniciales y procedimientos de inspección de
componentes. Si existe una falla que pueda
comprometer la seguridad, no se debe conectar
ningún suministro eléctrico al circuito hasta que
se resuelva satisfactoriamente. Si la falla no se
puede corregir de inmediato, pero es necesario
continuar la operación, se debe utilizar una
solución temporal adecuada. Esto se informará
al propietario del equipo para que se informe a
todas las partes.
Los controles iniciales de seguridad incluirán:
Que los condensadores están descargados. Esto
debe hacerse de manera segura para evitar la
posibilidad de chispas.
Que no se exponen componentes eléctricos
ni cableado mientras se está cargando,
recuperando o purgando el sistema.
Que hay continuidad de la unión de la tierra.
Reparaciones a componentes sellados.
1. Durante las reparaciones de componentes
sellados, todos los suministros eléctricos se
deben desconectar del equipo en el que se
está trabajando antes de retirar las cubiertas
selladas, etc. Si es absolutamente necesario
contar con un suministro eléctrico al equipo
durante el servicio, se debe realizar una
detección permanente de fugas. se ubicará en el
punto más crítico para advertir de una situación
potencialmente peligrosa.
2. Para garantizar que al trabajar con
componentes eléctricos, la carcasa no se altera
de tal manera que el nivel de protección se vea
afectado, se debe prestar especial atención a lo
siguiente:
Daños a los cables, número excesivo de
conexiones, terminales no fabricados según las
especifi caciones originales, daños a los sellos,
ajuste incorrecto de los casquillos, etc.
Asegúrese de que el aparato esté montado de
forma segura.
Asegúrese de que los sellos o materiales de
sellado no se hayan degradado de manera
que ya no sirvan para evitar la entrada de
atmósferas infl amables. Las piezas de repuesto
deben estar de acuerdo con las especifi caciones
del fabricante.
Nota: el uso de sellador de silicona puede
inhibir la efectividad de algunos tipos de
equipos de detección de fugas. Los componentes
intrínsecamente seguros no tienen que estar
aislados antes de trabajar en ellos.
Reparación a componentes intrínsecamente
seguros.
No aplique ninguna carga inductiva o capacitiva
permanente al circuito sin asegurarse de que esto
no exceda el voltaje y la corriente permitidos para
el equipo en uso. Los componentes intrínsecamente
seguros son los únicos tipos en los que se puede
trabajar mientras se vive en presencia de una
atmósfera infl amable. El aparato de prueba debe
estar en la clasifi cación correcta. Reemplace los
componentes solo con partes especifi cadas por
el fabricante. Otras partes pueden provocar la
ignición de refrigerante en la atmósfera debido a
una fuga.
36
Importantes Instrucciones de Seguridad
LEA Y SIGA TODAS LAS INSTRUCCIONES DE SEGURIDAD
Traslado y evacuación
Al entrar en el circuito de refrigerante para realizar
reparaciones o para cualquier otro propósito, se
deben utilizar procedimientos convencionales.
Sin embargo, es importante que se sigan las
mejores prácticas ya que la infl amabilidad es
una consideración. Se seguirán los siguientes
procedimientos:
Retire el refrigerante.
Purgar el circuito con gas inerte.
• Evacuar.
Purgar de nuevo con gas inerte.
Abrir el circuito mediante corte o soldadura
fuerte.
La carga de refrigerante se recuperará en los
cilindros de recuperación correctos. El sistema
se debe lavar con OFN para que la unidad
sea segura. Este proceso puede necesitar
repetirse varias veces. No se debe utilizar aire
comprimido ni oxígeno para esta tarea.
El lavado se logrará rompiendo el vacío en el
sistema con OFN y continuando con el llenado
hasta que se alcance la presión de trabajo,
luego ventilando a la atmósfera y fi nalmente
bajando al vacío. Este proceso debe repetirse
hasta que no haya refrigerante dentro del
sistema. Cuando se utiliza la carga OFN
nal, el sistema debe descargarse a presión
atmosférica para permitir que se realice el
trabajo. Esta operación es absolutamente vital si
se realizan operaciones de soldadura fuerte en
la tubería.
Asegúrese de que la salida de la bomba de
vacío no esté cerca de ninguna fuente de
ignición y que haya ventilación disponible.
Procedimientos de carga
Además de los procedimientos de carga
convencionales, se deben seguir los siguientes
requisitos:
Asegúrese de que no se contamine con
refrigerantes diferentes cuando utilice equipos
de carga. Las mangueras o líneas deben ser lo
más cortas posible para minimizar la cantidad
de refrigerante que contienen.
Los cilindros se mantendrán en posición vertical.
Asegúrese de que el sistema de refrigeración
esté conectado a tierra antes de cargar el
sistema con refrigerante.
Etiquete el sistema cuando se complete la carga,
si no está ya etiquetado.
Se debe tener mucho cuidado de no
sobrecargar el sistema de refrigeración.
Antes de recargar el sistema, se someterá a
prueba de presión con OFN. El sistema debe
ser probado contra fugas al fi nalizar la carga
pero antes de la puesta en servicio. Se realizará
una prueba de fugas de seguimiento antes de
abandonar el sitio.
Cableado
Compruebe que el cableado no esté sujeto a
desgaste, corrosión, presión excesiva, vibración,
bordes afi lados o cualquier otro efecto ambiental
adverso. La verifi cación también debe tener
en cuenta los efectos del envejecimiento o la
vibración continua de fuentes como compresores o
ventiladores.
Detección de refrigerantes infl amables.
Bajo ninguna circunstancia deben utilizarse fuentes
potenciales de ignición en la búsqueda o detección
de fugas de refrigerante. No se debe usar una
antorcha de halogenuros o cualquier otro detector
que use una llama desnuda.
Métodos de detección de fugas
Los siguientes métodos de detección de fugas se
consideran aceptables para sistemas que contienen
refrigerantes infl amables:
Se deben usar detectores electrónicos de fugas
para detectar refrigerantes infl amables, pero la
sensibilidad puede no ser adecuada o puede
necesitar una recalibración. El equipo de
detección debe estar calibrado en un área libre
de refrigerante. Asegúrese de que el detector no
sea una fuente potencial de ignición y que sea
adecuado para el refrigerante utilizado.
El equipo de detección de fugas se fi jará en un
porcentaje del LFL del refrigerante y se calibrará
para el refrigerante empleado y se confi rmará
el porcentaje apropiado de gas (25% máximo).
Los fl uidos de detección de fugas son adecuados
para el uso con la mayoría de los refrigerantes,
pero se debe evitar el uso de detergentes
que contengan cloro, ya que el cloro puede
reaccionar con el refrigerante y corroer el cobre
o las tuberías.
Si se sospecha una fuga, todas las llamas
descubiertas deben retirarse o extinguirse.
Si se encuentra una fuga de refrigerante que
requiere soldadura fuerte, todo el refrigerante
se recuperará del sistema o se aislará mediante
válvulas de cierre en una parte del sistema
alejada de la fuga. El nitrógeno libre de
oxígeno (OFN) se purgará a través del sistema
antes y durante el proceso de soldadura fuerte.
37
Importantes Instrucciones de Seguridad
LEA Y SIGA TODAS LAS INSTRUCCIONES DE SEGURIDAD
Desmantelamiento
Antes de llevar a cabo este procedimiento,
es esencial que el técnico esté completamente
familiarizado con el equipo en todo su detalle.
Se recomienda una buena práctica que todos los
refrigerantes se recuperen de manera segura. Antes
de realizar la tarea, se debe tomar una muestra
de aceite y refrigerante en caso de que se requiera
un análisis antes de reutilizar el refrigerante
recuperado. Es esencial que la energía eléctrica
esté disponible antes de comenzar la tarea.
A. Familiarizarse con el equipo y su
funcionamiento.
B. Sistema de aislamiento eléctrico.
C. Antes de intentar el procedimiento, asegúrese
de que:
El equipo de manejo mecánico está
disponible si es necesario para el manejo de
cilindros de refrigerante.
Todo el equipo de protección personal
está disponible y se está utilizando
correctamente.
El proceso de recuperación es supervisado
en todo momento por una persona
competente.
Los equipos y cilindros de recuperación
cumplen con las normas apropiadas.
D. Bombear el sistema de refrigerante, si es
posible.
E. Si no es posible un vacío, haga un colector para
que se pueda eliminar el refrigerante de varias
partes del sistema.
F. Asegúrese de que el cilindro esté situado
en la balanza antes de que tenga lugar la
recuperación.
G. Arranque la máquina de recuperación y opere
de acuerdo con las instrucciones del fabricante.
H. No llene en exceso los cilindros. No más del
80% de volumen de carga líquida.
I. No exceda la presión máxima de trabajo del
cilindro, ni siquiera temporalmente.
J. Cuando los cilindros se hayan llenado
correctamente y se haya completado el proceso,
asegúrese de que los cilindros y el equipo
se retiren del sitio rápidamente y que todas
las válvulas de aislamiento del equipo estén
cerradas.
K. El refrigerante recuperado no debe cargarse en
otro sistema de refrigeración a menos que se
haya limpiado y revisado.
Etiquetado
El equipo debe estar etiquetado indicando que ha
sido retirado del servicio y vaciado de refrigerante.
La etiqueta deberá estar fechada y fi rmada.
Asegúrese de que haya etiquetas en el equipo
que indiquen que el equipo contiene refrigerante
infl amable.
Recuperación
Cuando se retira refrigerante de un sistema, ya sea
para servicio o cierre, se recomienda que todos los
refrigerantes se eliminen de manera segura.
Cuando transfi era refrigerante a los cilindros,
asegúrese de que solo se utilicen los cilindros
apropiados para recuperar el refrigerante.
Asegúrese de que esté disponible el número
correcto de cilindros para mantener la carga total
del sistema. Todos los cilindros que se utilizarán
están diseñados para el refrigerante recuperado y
etiquetados para ese refrigerante, es decir, cilindros
especiales para la recuperación de refrigerante.
Los cilindros deben estar completos con válvula de
alivio de presión y válvulas de cierre asociadas en
buen estado de funcionamiento. Los cilindros de
recuperación vacíos se evacuan y, si es posible, se
enfrían antes de que se produzca la recuperación.
El equipo de recuperación debe estar en buen
estado de funcionamiento con un conjunto de
instrucciones sobre el equipo que se encuentra a
mano y debe ser adecuado para la recuperación
de refrigerantes infl amables. Además, un conjunto
de balanzas calibradas estará disponible y en buen
estado de funcionamiento. Las mangueras deben
estar completas con acoplamientos de desconexión
sin fugas y en buenas condiciones. Antes de
usar la máquina de recuperación, verifi que que
esté en buen estado de funcionamiento, que se
haya mantenido correctamente y que todos los
componentes eléctricos asociados estén sellados
para evitar la ignición en caso de una fuga de
refrigerante. Consulte al fabricante en caso de
duda.
El refrigerante recuperado se devolverá al
proveedor de refrigerante en el cilindro de
recuperación correcto y se dispondrá la nota de
transferencia de residuos correspondiente. No
mezcle refrigerantes en unidades de recuperación
y especialmente en cilindros. Si se deben retirar
los compresores o los aceites de compresores,
asegúrese de que hayan sido evacuados a un
nivel aceptable para asegurarse de que no quede
refrigerante infl amable dentro del lubricante. El
proceso de evacuación se llevará a cabo antes
de devolver el compresor a los proveedores.
Para acelerar este proceso solo debe emplearse
calentamiento eléctrico del cuerpo del compresor.
Cuando el aceite se drena de un sistema, debe
llevarse a cabo de manera segura.
38
INSTRUCCIONES DE INSTALACIÓN
39
HERRAMIENTAS REQUERIDAS
Destornilladores: Phillips y cabeza plana.
Taladro eléctrico: 3.2 mm (1/8 pulgada) de
diámetro de la broca
• Lápiz
• Cinta métrica
• Tijeras
Nivel de carpintero
ACCESORIOS
Los siguientes accesorios se incluyen con el aparato
y se deben utilizar durante la instalación.
1. Tornillos de 13 mm (1/2”) (x7)
2. Tornillos de 9,5 mm (3/8”) (X4) (instalados de
fábrica en algunos modelos).
3. Cerradura de seguridad
4. Sello de espuma adhesiva
5. Sello de espuma regular
6. Soporte de montaje en forma de “L” (instalado
de fábrica en algunos modelos).
7. Soporte para ventanas de madera (x2)
8. Soporte para ventanas de vinilo (x2)
9. Burlete (x5)
10. Cortinas laterales (x2)
UBICACIÓN
Este aire acondicionado está diseñado para
ventanas de una o dos ventanas. Dado que los
diseños de las ventanas varían, puede ser necesario
hacer algunas modifi caciones para una instalación
segura.
Este acondicionador de aire no está diseñado
para ventanas verticales de tipo deslizante o para
instalación “a través de la pared”.
Asegúrese de que la ventana y el marco estén
estructuralmente fi rmes y libres de madera seca o
podrida.
Instale el aire acondicionado en una ventana
en un costado del edifi cio que favorezca más
sombra que la luz solar. Si el electrodoméstico
debe estar expuesto a la luz solar directa, se
recomienda proporcionar un toldo de sombra
sobre el electrodoméstico para garantizar un
funcionamiento efi ciente.
No instale el aparato donde se sospeche una fuga
de gas combustible.
Este aparato está diseñado para evaporar la
condensación en condiciones normales. En
condiciones extremadamente cálidas o húmedas, el
exceso de condensación puede desbordarse hacia
el exterior. El aparato debe instalarse donde la
condensación no pueda gotear sobre peatones o
propiedades vecinas.
Deje sufi ciente espacio alrededor del aparato para
permitir una amplia circulación de aire. La parte
posterior del aparato debe estar al aire libre,
no debe estar en un garaje u otra habitación.
Mantenga el aparato alejado de obstáculos y al
menos a 76 cm (30”) del suelo. Asegúrese de que
las cortinas y otras obstrucciones no bloqueen el
ujo de aire al aparato.
76.2 cm
(30 pulgadas)
50.8 cm
(20 pulgadas)
50.8 cm
(20 pulgadas)
30.5 pulg
(12 cm)
1
2 3
4
5
6
9
8
7
10
INSTRUCCIONES DE INSTALACIÓN
40
SOPORTE L
El soporte en forma de “L” puede venir instalado de
fábrica en algunos modelos.
Si el soporte en forma de “L” no está preinstalado,
fíjelo a la parte superior del gabinete como se
muestra a continuación utilizando los tornillos de
9.5 mm (3/8“) provistos (x4).
INSTALACIÓN
Fije las cortinas laterales al aparato deslizando el
marco de la cortina en el canal lateral del gabinete.
Las cortinas están etiquetadas como “izquierda” y
“derecha” en los marcos. Esto se refi ere a los lados
izquierdo y derecho del aparato cuando se mira
hacia la parte frontal del aparato.
Corte el sello de espuma regular para que se ajuste
al área del alféizar de la ventana sobre la que
descansará el aire acondicionado.
Coloque el aire acondicionado en la ventana con el
soporte de montaje en forma de “L” colocado frente
a la hoja superior. La parte inferior del gabinete
debe colocarse en la parte empotrada del marco de
la ventana. Tire de la hoja superior de la ventana
hacia abajo hasta que descanse justo detrás de la
brida delantera del soporte de montaje en forma de
“L”.
Expanda las cortinas laterales en cada lado y
asegure la parte superior de los marcos al marco
de la ventana con un tornillo de 13 mm (1/2 “) en
cada lado del soporte de montaje en forma de” L “.
Fije las abrazaderas en la parte inferior de cada
cortina al alféizar de la ventana con un tornillo de
13 mm (1/2 ”) a cada lado del gabinete.
Coloque el sello de espuma adhesiva en la abertura
entre las ventanas interior y exterior y fi je la
cerradura de seguridad al marco de la ventana
exterior con dos tornillos de 13 mm (1/2 ”).
A
Compruebe el ángulo de inclinación
El acondicionador de aire debe inclinarse hacia
abajo hacia el exterior aproximadamente de 3° a
4°. Esta inclinación estimulará el drenaje del agua
condensada hacia el exterior. Si hay fugas de agua
condensada en el interior de la casa, compruebe el
ángulo de inclinación y ajuste si es necesario.
Mida el ángulo de inclinación desde el frente del
borde del gabinete. La diferencia de altura entre
la parte delantera y la parte posterior del aparato,
denominada “A” en la imagen inferior, debe ser
de aproximadamente 19 mm a 2.5 cm (3/4 de
pulgada - 1 pulgada).
PANEL DE CONTROL
1. Receptor de control remoto: Asegúrese de que este receptor no esté oscurecido por cortinas u otros
elementos, ya que podría afectar el funcionamiento del control remoto.
2. Indicador luminoso Sígueme: Se ilumina cuando la función Sígueme está activa. Sólo se puede ajustar
desde el mando a distancia.
3. Botón de encendido: Se utiliza para encender o apagar el aparato.
4. Botón de modo: Se utiliza para elegir el modo de funcionamiento.
5. Flechas arriba y abajo: Se utiliza para ajustar la temperatura ajustada en incrementos de 1 ° y la
función del temporizador en incrementos de 30 minutos hasta 10 horas y luego en incrementos de 1
hora hasta 24 horas.
6. Panel de visualización: Muestra la temperatura ajustada, la temperatura ambiente y los ajustes del
temporizador. Para cambiar la escala de temperatura que se está visualizando, presione los botones
arriba y abajo al mismo tiempo.
7. Botón del ventilador: Se utiliza para ajustar la velocidad del ventilador. El ventilador puede ajustarse a
Bajo, Medio, Alto y Auto.
8. Botón de conexión inalámbrica: se utiliza para conectarse a una red inalámbrica.
9. Botón de ahorro de energía: Se utiliza para confi gurar la función de ahorro de energía.
10. Botón ltro: La luz indicadora se iluminará como un recordatorio para comprobar el fi ltro. Una vez
limpiado el fi ltro, utilice este botón para reanudar el funcionamiento.
11. Botón dormir: Se utiliza para confi gurar la función dormir.
12. Botón del temporizador: Se utiliza para establecer el temporizador de encendido automático y
apagado automático.
1
2
3
4 5
6
7
8
9
10
11 12
41
INSTRUCCIONES DE OPERACIÓN
INSTRUCCIONES DE OPERACIÓN
42
TEMP
1
2
3
4
5
6
7
8
9
10
11
12
13
CONTROL REMOTO
1. Panel de visualización: Muestra la temperatura
establecida, la temperatura ambiente y la
confi guración del temporizador. Para cambiar
la escala de temperatura que se muestra,
presione el botón °C/°F.
2. Flechas arriba y abajo: Se utiliza para ajustar
la temperatura ajustada en incrementos de 1 °
y la función del temporizador en incrementos
de 30 minutos hasta 10 horas y luego en
incrementos de 1 hora hasta 24 horas.
3. Botón de modo: Se utiliza para elegir el modo
de funcionamiento.
4. Botón Sígueme: Se utiliza para confi gurar la
función sígueme.
5. Botón °C/°F: Use para cambiar la escala de
temperatura.
6. Botón LED: Presione para encender o apagar la
luz trasera del LED.
7. Botón de encendido: Se utiliza para encender o
apagar el aparato.
8. Botón de dormir: Se utiliza para establecer la
función de dormir.
9. Botón del ventilador: Se utiliza para ajustar la
velocidad del ventilador. El ventilador puede
ajustarse a bajo, medio, alto y auto.
10. Botón de encendido del temporizador: se utiliza
para confi gurar el temporizador de encendido
automático.
11. Botón de apagado del temporizador: se utiliza
para confi gurar el temporizador de apagado
automático.
12. Botón de ahorro de energía: Se utiliza para
confi gurar la función de ahorro de energía.
13. Botón de bloqueo: Presione el botón °C/°F
y el botón del temporizador al mismo tiempo
para bloquear el control remoto y evitar que la
confi guración se cambie sin darse cuenta.
43
INSTRUCCIONES DE OPERACIÓN
PILAS DEL CONTROL REMOTO
El mando a distancia requiere dos pilas
alcalinas AAA (incluidas). Las baterías deben ser
reemplazadas cuando:
a) No se escucha ningún sonido al intentar
programar el aparato.
b) El aparato no responde a una orden emitida por
el mando a distancia.
Cambio de batería:
1. Deslice la cubierta posterior del mando a
distancia en la dirección de la fl echa.
2. Inserte dos pilas AAA siguiendo la misma
orientación que se muestra en el interior de la
cámara de la batería (+/-).
3. Vuelva a instalar la cubierta trasera.
4. Si el mando a distancia no se utilizará durante
períodos de tiempo prolongados, las baterías se
deben quitar.
Notas:
Proteja el control remoto de altas temperaturas
y manténgalo alejado de la exposición a la
radiación.
Mantenga el receptor del panel de control
alejado de la luz directa del sol.
No mezcle baterías viejas y nuevas.
No mezcle pilas alcalinas, estándar (carbono-
zinc) o recargables (ni-cad, ni-mh, etc.).
El control remoto funciona a una distancia de 8
metros (26 pies) del receptor situado dentro del
aparato principal. Cualquier obstrucción entre el
receptor y el remoto puede causar interferencia
de señal, limitando la capacidad de programar
la unidad principal.
MODOS DE FUNCIONAMIENTO
Hay cuatro modos de operación para elegir.
Presione el botón de modo varias veces para elegir
el modo deseado. La luz indicadora adyacente
se iluminará para mostrar qué modo ha sido
seleccionado.
• Modo fresco
Elija el modo frío para confi gurar la función
de enfriamiento. Use las fl echas hacia arriba y
hacia abajo para elegir la temperatura deseada.
Cuando se selecciona el modo frío, la velocidad del
ventilador se puede ajustar presionando el botón
del ventilador.
• Modo seco
Elija el modo seco para eliminar el exceso de
humedad del aire durante los períodos de alta
humedad. Toda el agua extraída del aire se
condensará dentro del aparato y drenará la parte
posterior. La velocidad del ventilador se establecerá
automáticamente y no se puede modifi car en modo
seco.
Modo de ventilador
Elija el modo de ventilador para hacer funcionar
el ventilador interno sin activar la función de
enfriamiento. Presione el botón del ventilador varias
veces para elegir la velocidad del ventilador.
• Modo automático
El modo automático es un programa de fábrica
preestablecido que defi ne automáticamente el
modo y la velocidad del ventilador en función de la
temperatura establecida, la temperatura ambiente y
la humedad ambiental.
FLECHAS ARRIBA Y ABAJO
Las fl echas hacia arriba y hacia abajo modifi carán
la temperatura establecida en incrementos de 1°.
Las fl echas hacia arriba y hacia abajo
modifi carán el tiempo establecido de la función del
temporizador en incrementos de 0,5 horas hasta 10
horas y luego en incrementos de 1 hora hasta 24
horas como máximo.
INSTRUCCIONES DE OPERACIÓN
44
DORMIR
La función de dormir se puede utilizar para
conservar energía durante las horas de dormir.
Cuando se selecciona, la temperatura establecida
aumentará en 1°C/2°F cada media hora durante
una hora completa. El aparato mantendrá la nueva
temperatura establecida durante 6 horas antes de
volver automáticamente al funcionamiento normal.
La función de dormir se puede cancelar en
cualquier momento presionando el botón de dormir.
AHORRADOR DE ENERGÍA
La función de ahorro de energía encenderá y
apagará automáticamente el ventilador cuando
el compresor no esté en uso para minimizar
la frecuencia con la que el compresor necesita
encenderse.
Cuando se selecciona, el ventilador continuará
funcionando durante 3 minutos después de que se
apague el compresor. El ventilador se encenderá
durante 2 minutos en intervalos de 10 minutos
hasta que la temperatura ambiente esté por encima
de la temperatura establecida, momento en el
cual el compresor se encenderá y se reanudará el
enfriamiento.
SÍGUEME
Hay un sensor de temperatura integrado en el
control remoto que controlará la temperatura
ambiente. Mantenga el control remoto con usted y
el aparato ajustará automáticamente la temperatura
establecida en función de la temperatura donde se
encuentre.
El control remoto mostrará la temperatura en su
ubicación. El control remoto enviará una señal al
aire acondicionado cada 3 minutos, siempre que
permanezca dentro del alcance del aparato.
La luz sígueme en el panel de control se iluminará
durante 5 segundos cada 3 minutos para indicar
que ha recibido una señal del control remoto. Si
el aparato no recibe una señal del control remoto
durante un intervalo de 7 minutos, emitirá un pitido
para indicar que el modo Sígueme ha fi nalizado.
La distancia máxima para la función sígueme
es de 8 metros (26 pies). Esta característica está
disponible en modos fresco y automático.
CONEXIÓN INALÁMBRICA
Este dispositivo se puede controlar con una
aplicación inalámbrica en su dispositivo
inalámbrico.
Visite https://www.danby.com/support/#apps
para descargar la aplicación y obtener información
sobre su funcionamiento.
INSTRUCCIONES DE OPERACIÓN
45
TEMPORIZADOR
El temporizador se puede usar para encender
o apagar el aparato después de un período de
tiempo establecido.
El panel de control tiene un botón de temporizador.
Presione una vez para confi gurar el temporizador
de apagado automático y dos veces para
confi gurar el temporizador de apagado automático.
El control remoto tiene botones de encendido y
apagado del temporizador separados.
Temporizador de encendido automático
1. Presione el botón del temporizador en el control
remoto o presione el botón del temporizador en
el panel de control dos veces.
2. Use las fl echas hacia arriba y hacia abajo para
seleccionar la cantidad de tiempo deseada
antes de que el aparato se encienda.
3. Use el botón de modo para seleccionar el modo
deseado.
4. Use el botón del ventilador para seleccionar la
velocidad deseada del ventilador.
5. El tiempo seleccionado aparecerá en el panel de
visualización y hará una cuenta regresiva hasta
que se encienda el aparato.
Temporizador de apagado automático
1. Presione el botón de apagado del temporizador
en el control remoto o presione el botón del
temporizador en el panel de control una vez.
2. Use las fl echas hacia arriba y hacia abajo para
seleccionar la cantidad de tiempo deseada antes
de que el aparato se apague. El dispositivo se
ejecutará en el modo seleccionado actualmente.
3. El tiempo seleccionado aparecerá en el panel de
visualización y hará una cuenta regresiva hasta
que el aparato se apague.
Uso de temporizadores de encendido y
apagado simultáneamente
Los temporizadores de encendido y apagado se
pueden usar al mismo tiempo.
Para confi gurar el aparato para que se encienda,
ejecute durante un período de tiempo establecido y
luego apague, confi gure primero el temporizador
de encendido automático y luego confi gure el
temporizador de apagado automático.
Para confi gurar el dispositivo para que funcione
durante un período de tiempo, apague durante un
período de tiempo y luego vuelva a encenderlo,
confi gure primero el temporizador de apagado
automático y luego confi gure el temporizador de
encendido automático.
Ambas luces indicadoras se iluminarán y la
pantalla hará una cuenta regresiva para que el
aparato se apague o se encienda, cualquiera que
sea la función que se confi guró primero.
El temporizador no encenderá y apagará
el electrodoméstico indefi nidamente. Los
temporizadores de encendido y apagado
funcionarán una vez y luego el dispositivo volverá
al funcionamiento normal.
Apagar el dispositivo o desenchufarlo borrará
todas las confi guraciones de memoria, incluido el
temporizador.
46
INSTRUCCIONES DE OPERACIÓN
FILTRO DE AIRE
El fi ltro de aire debe limpiarse aproximadamente
cada 2 semanas. El fi ltro de aire puede requerir
una limpieza más frecuente si hay caspa o pelaje
en el aire.
Aproximadamente cada dos semanas, la luz
indicadora del fi ltro en el panel de control se
iluminará como un recordatorio para limpiar el
ltro. Siga los pasos que se indican a continuación
para limpiar el fi ltro y volver a ponerlo en
funcionamiento normal.
1. El ltro de aire se encuentra detrás de la rejilla
de admisión delantera. Para quitar el fi ltro
de aire, sujete la lengüeta del fi ltro en el lado
derecho de la parrilla y deslícela hacia la
derecha. Si la rejilla de admisión delantera tiene
dos muescas, tire de la parrilla hacia adelante
para quitar el fi ltro de aire.
2. Utilice una aspiradora con un accesorio de
cepillo suave para eliminar los residuos grandes
o acumulación de polvo del fi ltro de aire.
3. Lave el fi ltro en agua tibia jabonosa, por debajo
de 40°C (104°F), o utilice un agente de limpieza
neutro.
4. Enjuague el fi ltro con agua limpia y séquelo
completamente antes de volver a instalarlo en el
aparato.
5. Pulse el botón de fi ltro en el panel de control
para reanudar el funcionamiento normal.
Nota: No opere el aparato sin el fi ltro de aire
instalado.
CÓDIGOS DE ERROR
Si el panel de visualización muestra alguno de los
siguientes códigos de error, desenchufe el aparato,
déjelo reposar durante 5-10 minutos y vuelva a
enchufarlo. Si el error persiste, llame al servicio
técnico.
AS - Error del sensor de temperatura ambiente
HI - Error del sensor de temperatura
LO - Error del sensor de temperatura
. - Error del sensor de temperatura del evaporador
LIMPIEZA
Para evitar posibles descargas eléctricas, asegúrese
de que el aparato esté desenchufado antes de
realizar cualquier limpieza o mantenimiento.
El exterior del aparato se puede limpiar con un
paño suave o con un paño tibio y húmedo si es
necesario.
No utilice gasolina, benceno, diluyente o cualquier
otro producto químico para limpiar este aparato ya
que estas sustancias pueden dañar el acabado y la
deformación de las piezas de plástico.
Nunca vierta agua directamente sobre el
aparato, ya que esto puede causar el deterioro
de los componentes eléctricos y el aislamiento del
cableado.
CUIDADO DE FINAL DE TEMPORADA
Antes de dejar el aparato en servicio durante
el año, haga funcionar el aparato en modo de
ventilador alto durante medio día para asegurarse
de que el interior del aparato esté seco. Esto
ayudará a evitar el crecimiento de moho o moho
dentro del aparato. Asegúrese de que el fi ltro esté
limpio y seco. Guarde el aparato en un lugar seco.
Nota: Al instalar o quitar el aparato de la ventana,
asegúrese de que se tome precaución para evitar
que caiga hacia atrás. Se recomienda que la
instalación o remoción se complete con ayuda para
evitar lesiones a personas o daños a la propiedad o
al aparato.
DISPOSICIÓN
Compruebe la conformidad reglamentaria local con
respecto a la eliminación aprobada y segura de
este electrodoméstico.
SOLUCIÓN DE PROBLEMAS
PROBLEMA CAUSA POSIBLE
El aparato no funcionará El enchufe no está completamente insertado en el tomacorriente
de pared
Fusible fundido o disyuntor
Enfriamiento insufi ciente • El ltro de aire está sucio
Flujo de aire bloqueado
El tamaño del dispositivo es demasiado pequeño para la
aplicación
Ruido Soporte inadecuado en la instalación de ventanas
Olores Formación de moho o moho en super cies mojadas internas
Coloque un comprimido de algicida en el molde de la base;
empuje la tableta a través de la parrilla a cada lado del aparato
El agua que gotea en el interior El aparato no está correctamente inclinado para permitir que el
agua se drene hacia el exterior
El agua que gotea fuera En días muy calurosos o húmedos, el agua goteada por la parte
trasera del aparato es normal
Acumulación de escarcha Cuando las temperaturas exteriores están por debajo de 18.3°C
(65°F) puede formarse escarcha cuando el aparato esté en
modo de enfriamiento
Cambie el aparato al modo ventilador sólo hasta que el hielo se
derrita
47
Danby cuidado del consumidor: 1-800-263-2629 o consumerservice@danby.com
Horas de operación:
Lunes a Jueves 8:30 am - 6:00 pm Hora estándar del este
Viernes 8:30 am - 4:00 pm Hora estándar del este
La información de este manual está sujeta a cambios sin previo aviso.
Este aparato digital de Clase B cumple con la
norma Canadiense ICES-003. CAN ICES-3 (B)
Este equipo ha sido probado y cumple con los
límites para un dispositivo digital de Clase B, de
acuerdo con la Parte 15 de las Reglas de la FCC.
Estos límites están diseñados para proporcionar una
protección razonable contra interferencias en una
instalación residencial.
Este equipo genera, utiliza y puede irradiar energía
de radiofrecuencia y, si no se instala y utiliza
de acuerdo con las instrucciones, puede causar
interferencia en las comunicaciones de radio. Sin
embargo, no hay garantía de que no se produzcan
interferencias en una instalación en particular.
Si este equipo causa interferencias en la recepción
de radio o televisión, lo que puede determinarse
apagando y encendiendo el equipo, se recomienda
al usuario que intente corregir la interferencia
mediante una o más de las siguientes medidas:
1. Reorientar o reubicar la antena receptora.
2. Aumente la separación entre el equipo y el
receptor.
3. Conecte el equipo a una toma de corriente en
un circuito distinto al que está conectado el
receptor.
4. Consulte al distribuidor oa un técnico de radio /
TV experimentado para obtener ayuda.
Los cambios o modifi caciones no aprobados por
la parte responsable del cumplimiento de la FCC
podrían anular la autoridad del usuario para
operar el equipo.
Este aparato cumple con la Parte 15 de las Reglas
de la FCC.
El funcionamiento está sujeto a las dos condiciones
siguientes:
1. Este dispositivo no puede causar interferencias.
2. Este dispositivo debe aceptar cualquier
interferencia recibida, incluida la interferencia
que pueda causar un funcionamiento no
deseado.
LIMITED IN-HOME APPLIANCE WARRANTY
This quality product is warranted to be free from manufacturer’s defects in material and workmanship, provided that the unit is used under the normal operating
conditions intended by the manufacturer.
This warranty is available only to the person to whom the unit was originally sold by Danby Products Limited (Canada) or Danby Products Inc. (U.S.A.) (hereafter
“Danby”) or by an authorized distributor of Danby, and is non-transferable.
TERMS OF WARRANTY
Plastic parts, are warranted for thirty (30) days only from purchase date, with no extensions provided.
First Year
During the rst twelve (12) months, any functional parts of this product found to be defective, will be repaired or replaced, at warrantor’s
option, at no charge to the ORIGINAL purchaser.
To obtain
Danby reserves the right to limit the boundaries of “In Home Service” to the proximity of an Authorized Service Depot. Any app liance
Service
requiring service outside the limited boundaries of “In Home Service” , it will be the consumer’s responsibility to transport the appliance (at
their own expense) to the original retailer (point of purchase) or a service depot for repair. See “Boundaries of In Home Serv ice” below.
Contact your dealer from whom your unit was purchased, or contact your nearest authorized Danby service depot, where service
must be performed by a qualied service technician.
If service is performed on the units by anyone other than an authorized service depot, or the unit is used for commercial appli cation, all
obligations of Danby under this warranty shall be void.
Boundaries of
If the appliance is installed in a location that is 100 kilometers (62 miles) or more from the nearest service center your unit must be
In Home Service
delivered to the nearest authorized Danby Service Depot, as service must only be performed by a technician qualied and certif ied for
warranty service by Danby. Transportation charges to and from the service location are not protected by this warranty and are t he
responsibility of the purchaser.
Nothing within this warranty shall imply that Danby will be responsible or liable for any spoilage or damage to food or other c ontents of this appliance, whether due
to any defect of the appliance, or its use, whether proper or improper.
EXCLUSIONS
Save as herein provided, Danby, there are no other warranties, conditions, representations or guarantees, express or implied, m ade or intended by Danby or its
authorized distributors and all other warranties, conditions, representations or guarantees, including any warranties, conditio ns, representations or guarantees
under any Sale of Goods Act or like legislation or statue is hereby expressly excluded. Save as herein provided, Danby shall no t be responsible for any damages
to persons or property, including the unit itself, howsoever caused or any consequential damages arising from the malfunction o f the unit and by the purchase of
the unit, the purchaser does hereby agree to indemnify and hold harmless Danby from any claim for damages to persons or propert y caused by the unit.
GENERAL PROVISIONS
No warranty or insurance herein contained or set out shall apply when damage or repair is caused by any of the following:
1) Power failure.
2) Damage in transit or when moving the appliance.
3) Improper power supply such as low voltage, defective house wiring or inadequate fuses.
4) Accident, alteration, abuse or misuse of the appliance such as inadequate air circulation in the room or abnormal operating con ditions
(extremely high or low room temperature).
5) Use for commercial or industrial purposes (ie. If the appliance is not installed in a domestic residence).
6) Fire, water damage, theft, war, riot, hostility, acts of God such as hurricanes, oods etc.
7) Service calls resulting in customer education.
8) Improper Installation (ie. Building-in of a free standing appliance or using an appliance outdoors that is not approved for out door application).
Proof of purchase date will be required for warranty claims; so, please retain bills of sale. In the event warranty service is required, present this document to our
AUTHORIZED SERVICE DEPOT.
Danby Products Limited
PO Box 1778, Guelph, Ontario, Canada N1H 6Z9
Telephone: (519) 837-0920 FAX: (519) 837-0449
Danby Products Inc.
PO Box 669, Findlay, Ohio, U.S.A. 45840
Telephone: (419) 425-8627 FAX: (419) 425-8629
04/09
1-800-263-2629
Warranty Service
In-home
Durante los primeros veinticuatro (24) meses, cualquier parte en buen estado de este producto que resulte
defectuosa, incluyendo cualquier sistema sellado, será reparado o reemplazado, a opción del fabricante, sin
cargo para el comprador original.
Póngase en contacto con el distribuidor donde adquirió el electrodoméstico o póngase en contacto con el
centro de servicio autorizado más cercano de Danby, donde el servicio debe ser realizado por un técnico
cualificado. Si el servicio es realizado por cualquier persona que no sea un depósito de servicio autorizado,
todas las obligaciones de Danby bajo esta garantía serán nulas.
Es responsabilidad del comprador transportar el aparato al centro de servicio autorizado más cercano.
Primeros 24 meses
Para obtener servicio
GARANTÍA LIMITADA “ACARREADO SOLAMENTE”
Este producto de calidad está garantizado contra defectos de fabricación, incluyendo partes y mano de obra, siempre y cuando la
unidad se utilice bajo las condiciones normales de funcionamiento para las que fue diseñado.
Esta garantía está solamente disponible para la persona que haya comprado originalmente esta unidad directamente de Danby
Products Limited (Canada) o Danby Products Inc. (U.S.A.) (en adelante “Danby”) o uno de sus distribuidores autorizados, y no es
transferible.
CONDICIONES DE LA GARANTÍA
Las piezas plásticas, se autorizan por treinta (30) días solamente a partir de la fecha de la compra, sin las extensiones
proporcionadas.
Nada dentro de esta garantía implica que Danby será responsable por cualquier daño que hayan sufrido los alimentos u otros
contenidos de este aparato, ya sea debido a un defecto del aparato, o su uso, adecuado o inadecuado.
EXCLUSIONES
Salvo lo aquí indicado por Danby, no existen otras garantías, condiciones o representaciones, explícitas o implícitas, concretas o
intencionales por parte de Danby o sus distribuidores autorizados y todas las demás garantías, condiciones o representaciones,
incluyendo cualquier garantía, condiciones o representaciones bajo cualquier Acta de Venta de Productos o legislación o estatuto
similar, quedan de esta forma expresamente excluidas. Salvo lo aquí indicado, Danby no serán responsables por ningún daño a
personas o bienes, incluyendo la propia unidad, sin importar su causa, o de ningún daño indirecto causado por el desperfecto de la
unidad, y al comprar esta unidad, el comprador acepta por la presente, indemnizar y proteger a Danby contra cualquier reclamo
por daños a personas o bienes causados por la unidad.
CONDICIONES GENERALES
No se considerará ninguna de estas garantías o seguros cuando el daño o la necesidad de reparación sea el producto de los
siguientes casos:
1) Falla del suministro eléctrico.
2) Daños en tránsito o durante el transporte de la unidad.
3) Alimentación incorrecta, como bajo voltaje, instalación eléctrica defectuosa o fusibles inadecuados.
4) Accidente, modificación, abuso o uso incorrecto del artefacto, tal como insuficiente ventilación del ambiente o condiciones de
operación anormales (temperatura ambiente extremadamente alta o baja).
5) Utilización comercial o industrial (v.g., si el electrodoméstico no está instalado en una vivienda particular).
6) Incendio, daños por agua, robo, guerra, disturbios, hostilidades, actos de fuerza mayor como huracanes, inundaciones, etc.
7) Pedidos de servicio debido a desinformación del usuario.
8) Instalación inadecuada (v.g., instalación de un electrodoméstico independiente o uso de un aparato al aire libre que no esté
aprobado para aplicaciones en exteriores, incluyendo pero no limitado a: garajes, patios, porches o cualquier lugar que no esté bien
aislado o controlado por el clima).
Se requerirá una prueba de la fecha de compra para reclamaciones de garantía; conservar las facturas de venta. En el caso de que
se requiera servicio de garantía, presente el comprobante de compra a nuestro depósito de servicio autorizado.
Servicio de Garantía
Acarreado Solamente
Danby Products Limited
PO Box 1778, Guelph, Ontario, Canada N1H 6Z9
Telephone: (519) 837-0920 FAX: (519) 837-0449
Danby Products Inc.
PO Box 669, Findlay, Ohio, U.S.A. 45840
Telephone: (419) 425-8627 FAX: (419) 425-8629
1-800-263-2629
04/17
Los cargos de transporte desde y hacia el lugar de servicio no están protegidos por esta garantía y son responsabilidad del
comprador.
NOTES / REMARQUES / NOTAS :
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
NOTES / REMARQUES / NOTAS :
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
MODEL • MODÈLE • MODELO
Printed in China
Imprimé en Chine
Impreso en China
Danby Products Limited, Guelph, ON, Canada N1H 6Z9
Danby Products Inc., Findlay, Ohio, USA 45840
DAC060EB7WDB

Transcripción de documentos

OWNER’S MANUAL MANUEL DU PROPRIÉTAIRE MANUAL DEL PROPIETARIO AIR CONDITIONER Owner’s Manual.............................1 - 16 CLIMATISEUR Manual du propriétaire.................17 - 32 MODEL • MODÈLE • MODELO DAC060EB7WDB AIRE ACONDICIONADO Manual del propietario..................33 - 48 www.Danby.com DANBY PRODUCTS LIMITED, ONTARIO, CANADA N1H 6Z9 DANBY PRODUCTS INC., FINDLAY, OHIO, USA 45840 2019.12.05 Welcome Welcome to the Danby family. We are proud of our quality products and we believe in dependable service. We suggest that you read this owner’s manual before plugging in your new appliance as it contains important operation information, safety information, troubleshooting and maintenance tips to ensure the reliability and longevity of your appliance. Visit www.Danby.com to access self service tools, FAQs and much more. For additional assistance call 1-800-263-2629. Note the information below; you will need this information to obtain service under warranty. You must provide the original purchase receipt to validate your warranty and receive service. Model Number: _________________________________________________ Serial Number: _________________________________________________ Date of Purchase: _______________________________________________ Need Help? Before you call for service, here are a few things you can do to help us serve you better. Read this owner’s manual: It contains instructions to help you use and maintain your appliance properly. If you receive a damaged appliance: Immediately contact the retailer or builder that sold you the appliance. Save time and money: Check the troubleshooting section at the end of this manual before calling. This section will help you solve common problems that may occur. 1-800-26- Danby (1-800-263-2629) 1 Important Safety Information READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAFETY REQUIREMENTS GROUNDING INSTRUCTIONS DANGER: Risk of fire or explosion. Flammable refrigerant used. Do not damage the refrigerant circuit. This appliance must be grounded. Grounding reduces the risk of electrical shock by providing an escape wire for the electrical current. • Ensure that servicing is done by factory authorized service personnel, to minimize product damage or safety issues. • Consult repair manual or owner’s guide before attempting to service this product. All safety precautions must be followed. • Dispose of properly in accordance with federal or local regulations. • Follow handling instructions carefully. • Keep ventilation openings, in the appliance clear of obstruction. • Do not use mechanical devices or other means to accelerate the defrosting process. • Children should be supervised to ensure that they do not play with the appliance. • Do not store or install the appliance near continuously operating ignition sources such as open flames or a gas stove. • Do not operate near water or in a wet room. • Do not pierce or burn. • Be aware that refrigerants may not contain an odor. • The appliance must be stored so as to prevent mechanical damage from occurring. This appliance has a cord that has a grounding wire with a 3-prong plug. The power cord must be plugged into an outlet that is properly grounded. If the outlet is a 2-prong wall outlet, it must be replaced with a properly grounded 3-prong wall outlet. The serial rating plate indicates the voltage and frequency the appliance is designed for. WARNING - Improper use of the grounding plug can result in a risk of electric shock. Consult a qualified electrician or service agent if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is properly grounded. Do not connect your appliance to extension cords or together with another appliance in the same wall outlet. Do not splice the power cord. Do not under any circumstances cut or remove the third ground prong from the power cord. Do not use extension cords or ungrounded (two prongs) adapters. If the power supply cord is damaged, it must be replaced by the manufacturer, its service agent or similar qualified person in order to avoid hazard. All wiring must comply with local and national codes and must be installed by a qualified electrician. Check the available power supply and resolve any wiring problems before installing and operating this appliance. The rating plate located on the right side of the appliance just above the power cord contains electrical and other technical data. This appliance is not intended for use by persons (including children) whose physical, sensory or mental capabilities may be different or reduced, or who lack experience or knowledge, unless such persons receive supervision or training to operate the appliance by a person responsible for their safety. CAUTION: RISK OF FIRE Flammable refrigerant used. When maintaining or disposing of the air conditioner, the refrigerant must not be allowed to vent into the open air. SAVE THESE INSTRUCTIONS! 2 Important Safety Information READ AND FOLLOW ALL SAFETY INSTRUCTIONS Any person involved with working on the refrigerant circuit should hold a current, valid certificate from an industry accredited assessment authority which authorizes their competence to handle refrigerants safely in accordance with an industry recognized assessment specification. 5. Presence of fire extinguisher: If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or C02 fire extinguisher adjacent to the work area. Servicing shall only be performed as recommended by the manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants. 6. No ignition sources: No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to risk of fire or explosion. All possible ignition sources including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal during which flammable refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure there are no flammable hazards or ignition risks. No smoking signs shall be displayed. When maintaining or disposing of the appliance the refrigerant must be recovered properly and should not be allowed to discharge to the air directly. Information on servicing 1. Checks to the area: Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system. 7. Ventilated area: Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferable expel it externally into the atmosphere. 2. Work procedure: Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable gas or vapour being present while the work is being performed. 8. Checks to the refrigeration equipment: Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance. 3. General work area: All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the work space shall be sectioned off. Ensure that the conditions within the work area have been made safe by removing all flammable material. 4. Checking for the presence of refrigerant: The are shall be checked with an appropriate refrigerant detector prior to and during work to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. nonsparking, adequately sealed and intrinsically safe. 3 Important Safety Information READ AND FOLLOW ALL SAFETY INSTRUCTIONS The following checks shall be applied to installations using flammable refrigerants: Repairs to sealed components Initial safety checks shall include: Repair to intrinsically safe components • That capacitors are discharged. This shall be done in a safe manner to avoid possibility of sparking. • That no live electrical components and wiring are exposed while charging, recovering or purging the system. • That there is continuity of earth bonding. Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use. Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere. The test apparatus shall be at the correct rating. Replace components only with parts specified by the manufacturer. Other parts may result in the ignition of refrigerant in the atmosphere from a leak. 1. During repairs to sealed components, all • The charge size is in accordance with the room electrical supplies shall be disconnected from size within which the refrigerant containing the equipment being worked upon prior to any parts are installed. removal of sealed covers, etc. If it is absolutely • The ventilation machinery and outlets are necessary to have an electrical supply to operating adequately and are not obstructed. equipment during servicing then a permanently • If an indirect refrigerating circuit is being used, operating form of leak detection shall be located the secondary circuit shall be checked for the at the most critical point to warn of a potentially presence of refrigerant. hazardous situation. • Marking to the equipment continues to be visible and legible. Markings and signs that become 2. To ensure that by working on electrical illegible must be corrected. components the casing is not altered in such • Refrigeration pipe or components are installed in a way that the level of protection is affected, a position where they are unlikely to be exposed particular attention shall be paid to the to any substance which may corrode refrigerant following: containing components, unless the components are constructed of materials which are inherently • Damage to cables, excessive number of resistant to being corroded or are suitable connections, terminals not made to original protected against being corroded. specification, damage to seals, incorrect fitting of glands, etc. 9. Checks to electrical devices: Repair and • Ensure the apparatus is mounted securely. maintenance to electrical components shall • Ensure that seals or sealing materials have include initial safety checks and component not degraded such that they no longer serve inspection procedures. If a fault exists that the purpose of preventing the ingress of could compromise safety, then no electrical flammable atmospheres. Replacement parts supply shall be connected to the circuit until it shall be in accordance with the manufacturer’s is satisfactorily dealt with. If the fault cannot specifications. be corrected immediately but it is necessary to continue operation, an adequate temporary Note: The use of silicon sealant may inhibit the solution shall be used. This shall be reported to effectiveness of some types of leak detection the owner of the equipment so all parties are equipment. Intrinsically safe components do not advised. have to be isolated prior to working on them. 4 Important Safety Information READ AND FOLLOW ALL SAFETY INSTRUCTIONS Cabling Removal and evacuation Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects. The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans. When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used. However, it is important that the best practice is followed since flammability is a consideration. The following procedures shall be adhered to: Detection of flammable refrigerants • • • • • • Remove refrigerant. Purge the circuit with inert gas. Evacuate. Purge again with inert gas. Open the circuit by cutting or brazing. The refrigerant charge shall be recovered into the correct recovery cylinders. The system shall be flushed with OFN to render the unit safe. This process may need to be repeated several times. Compressed air or oxygen shall not be used for this task. • Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved, then venting to atmosphere and finally pulling down to a vacuum. This process shall be repeated until no refrigerant is within the system. When the final OFN charge is used, the system shall be vented down to atmospheric pressure to enable work to take place. This operation is absolutely vital is brazing operations on the pipe-work are to take place. • Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available. Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch or any other detector using a naked flame shall not be used. Leak detection methods The following leak detection methods are deemed acceptable for systems containing flammable refrigerants: • Electronic leak detectors shall be used to detect flammable refrigerants but the sensitivity may not be adequate or may need recalibration. Detection equipment shall be calibrated in a refrigerant-free area. Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used. • Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percentage of gas (25% maximum) is confirmed. • Leak detection fluids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper or pipe-work. • If a leak is suspected, all naked flames shall be removed or extinguished. • If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system or isolated by means of shut off valves in a part of the system remote from the leak. Oxygen free nitrogen (OFN) shall then be purged through the system both before and during the brazing process. Charging procedures In addition to conventional charging procedures, the following requirements shall be followed: • Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall be as short as possible to minimize the amount of refrigerant contained in them. • Cylinders shall be kept upright. • Ensure that the refrigeration system is earthed prior to charging the system with refrigerant. • Label the system when charging is complete, if not already labeled. • Extreme care shall be taken not to overfill the refrigeration system. • Prior to recharging the system it shall be pressure tested with OFN. The system shall be leak tested on completion of charging but prior to commissioning. A follow up leak test shall be carried out prior to leaving the site. 5 Important Safety Information READ AND FOLLOW ALL SAFETY INSTRUCTIONS Decommissioning Recovery Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment in all its detail. It is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant. It is essential that electrical power is available before the task is commenced. When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely. When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovers cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge are available. All cylinders to be used are designed for the recovered refrigerant and labeled for that refrigerant, i.e. special cylinders for the recovery of refrigerant. Cylinders shall be complete with pressure relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs. A. Become familiar with the equipment and its operation. B. Isolate system electrically. C. Before attempting the procedure ensure that: • Mechanical handling equipment is available if required for handling refrigerant cylinders. • All personal protective equipment is available and being used correctly. • The recovery process is supervised at all times by a competent person. • Recovery equipment and cylinders conform to the appropriate standards. D. Pump down refrigerant system, if possible. E. If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system. F. Make sure that cylinder is situated on the scales before recovery takes place. G. Start the recovery machine and operate in accordance with the manufacturer’s instructions. H. Do not overfill cylinders. No more than 80% volume liquid charge. I. Do not exceed the maximum working pressure of the cylinder, even temporarily. J. When the cylinders have been filled correctly and the process is completed, make sure that the cylinders and the equipment are removed from the site promptly and all isolation valves on the equipment are closed off. K. Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked. The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants. In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using the recovery machine, check that is it in satisfactory working order, has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant leak. Consult the manufacturer if in doubt. The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder and the relevant waste transfer note shall be arranged. Do not mix refrigerants in recovery units and especially not in cylinders. If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant. The evacuation process shall be carried out prior to returning the compressor to the suppliers. Only electric heating to the compressor body shall be employed to accelerate this process. When oil is drained form a system, it shall be carried out safely. Labeling Equipment shall be labeled stating that it has been decommissioned and emptied of refrigerant. The label shall be dated and signed. Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant. 6 INSTALLATION INSTRUCTIONS LOCATION REQUIRED TOOLS This air conditioner is designed for single or double hung windows. Since window designs vary, it may be necessary to make some modifications for safe installation. • • • • • • This air conditioner is not designed for vertical, slider type windows or “through the wall” installation. Screwdrivers: Phillips and flat head. Power Drill: 3.2mm (1/8”) diameter drill bit Pencil Measuring Tape Scissors Carpenter’s Level ACCESSORIES Ensure that the window and frame are structurally sound and free from dry or rotted wood. The following accessories are included with the appliance and should be used during the installation. Install the air conditioner in a window on a side of the building which favors more shade than sunlight. If the appliance must be in direct sunlight, it is advisable to provide a shade awning over the appliance to ensure efficient functioning. 1. 13 mm (1/2 inch) screws (x7) 2. 9.5 mm (3/8 inch) screws (x4) (Factory installed on some models.) 3. Safety Lock 4. Adhesive foam seal 5. Regular foam seal 6. “L” shaped mounting bracket (Factory installed on some models.) 7. Bracket for wood windows (x2) 8. Bracket for vinyl windows (x2) 9. Weather stripping (x5) 10. Side curtains (x2) Do not install the appliance where leakage of combustible gas is suspected. This appliance is designed to evaporate condensation under normal conditions. Under extremely hot or humid conditions, excess condensation may overflow to the outside. The appliance should be installed where condensation cannot drip on pedestrians or neighboring properties. Provide sufficient clearance around the appliance to allow ample air circulation. The rear of the appliance should be outdoors, it should not be in a garage or another room. Keep the appliance away from obstacles and at least 76 cm (30 inches) above the ground. Ensure that curtains and other obstructions do not block air flow to the appliance. 2 1 4 12 cm (30.5 in) 5 6 7 8 9 10 50.8 cm (20 inches) 76.2 cm (30 inches) 50.8 cm (20 inches) 7 3 INSTALLATION INSTRUCTIONS INSTALLATION Check the Tilt Angle Attach the side curtains to the appliance by sliding the curtain frame into the side channel of the cabinet. The curtains are labeled “left” and “right on the frames. This refers to the left and right sides of the appliance when facing the front of the appliance. The air conditioner should be tilted downward towards the outside approximately 3° to 4°. This tilt will encourage any condensed water to drain to the outside. If any condensed water leaks to the inside of the house, check the tilt angle and adjust as necessary. Cut the regular foam seal to fit the area of the window sill that the air conditioner will rest on. Measure the tilt angle from the front of the cabinet’s edge. The difference in height between the front and the back of the appliance, labeled “A” on the image below, should be approximately 19 mm - 2.5 cm (3/4” - 1”). Place the air conditioner into the window with the “L” shaped mounting bracket positioned in front of the upper sash. The bottom of the cabinet should be positioned on the recessed portion of the window frame. Pull the upper window sash down until it rests just behind the front flange of the “L” shaped mounting bracket. A Expand the side curtains on each side and secure the top of the frames to the window sash using one 13 mm (1/2”) screw on each side of the “L” shaped mounting bracket. Attach the clamps on the lower part of each curtain to the window sill using one 13 mm (1/2”) screw on each side of the cabinet. Place the adhesive foam seal into the opening between the inside and outside windows and attached the safety lock to the outside window frame using two 13 mm (1/2”) screws. L BRACKET The “L” shaped bracket may come factory installed on some models. If the “L” shaped bracket is not pre-installed, attach it to the top of the cabinet as shown below using the provided 9.5 mm (3/8”) screws (x4). 8 OPERATING INSTRUCTIONS CONTROL PANEL 1. Remote Control Receiver: Ensure this receiver is not obscured by curtains or other items as it could impact remote control functioning. 2. Follow Me Indicator Light: Illuminates when the Follow Me function is active. Follow Me can only be set from the remote control. 3. Power Button: Used to turn the appliance on or off. 4. Mode Button: Used to choose the operating mode. 5. Up and Down Arrows: Used to adjust the set temperature in 1° increments and the timer function in 30 minute increments up to 10 hours and then in 1 hour increments up to 24 hours. 6. Display Panel: Displays the set temperature, the ambient temperature and the timer settings. To change the temperature scale being displayed, press the up and down buttons at the same time. 7. Fan Button: Used to set the fan speed. The fan can be set to Low, Medium, High and Auto. 8. Wireless connect button: Used to connect to a wireless network. 9. Energy Saver Button: Used to set the energy saver function. 10. Filter Button: The indicator light will illuminate as a reminder to check the filter. Once the filter has been cleaned, use this button to resume operation. 11. Sleep Button: Used to set the Sleep function. 12. Timer Button: Used to set the auto on and auto off timer. 2 1 6 3 4 5 8 9 10 7 11 9 12 OPERATING INSTRUCTIONS REMOTE CONTROL 1. Display Panel: Displays the set temperature, the ambient temperature and the timer settings. To change the temperature scale being displayed, press the °C/°F button. 2. Up and Down Arrows: Used to adjust the set temperature in 1° increments and the timer function in 30 minute increments up to 10 hours and then in 1 hour increments up to 24 hours. 1 3. Mode Button: Used to choose the operating mode. 4. Follow Me Button: Used to set the follow me function. TEMP 5. °C/°F button: Use to change the temperature scale. 2 6. LED Button: Press to turn the LED back light on or off. 7. Power Button: Used to turn the appliance on or off. 7 3 8. Sleep Button: Used to set the sleep function. 9. Fan Button: Used to set the fan speed. The fan can be set to low, medium, high and auto. 8 4 9 10 10. Timer On Button: Used to set the auto on timer. 5 11. Timer Off Button: Used to set the auto off timer. 12. Energy Saver Button: Used to set the energy saver function. 11 13 13. Lock Button: Press the °C/°F button and the timer button at the same time to lock the remote control and prevent the settings from being inadvertently changed. 6 10 12 OPERATING INSTRUCTIONS REMOTE CONTROL BATTERIES OPERATING MODES The remote control requires two AAA alkaline batteries (included). Batteries should be replaced when: There are four operating modes to choose from. Press the mode button repeatedly to choose the desired mode. The adjacent indicator light will illuminate to show which mode has been selected. a) No sound is heard when attempting to program the appliance. b) The appliance does not respond to a command issued by the remote control. Battery replacement: 1. Slide the rear cover on the remote in the direction of the arrow. 2. Insert two AAA batteries following the same orientation depicted inside the battery chamber (+/-). 3. Reinstall the rear cover. 4. If the remote control will not be used for extended periods of time, the batteries should be removed. Notes: • Protect the remote control from high temperatures, and keep it away from radiation exposure. • Keep the control panel receiver out of direct sunlight. • Do not mix old and new batteries. • Do not mix alkaline, standard (carbon-zinc), or rechargeable (ni-cad, ni-mh,etc) batteries. • The remote operates within a range of 8 meters (26 ft.) from the receiver located inside the main appliance. Any obstruction between the receiver and remote may cause signal interference, limiting the ability to program the main unit. • Cool Mode Choose cool mode to set the cooling function. Use the up and down arrows to choose the desired temperature. When cool mode is selected, the fan speed can be adjusted by pressing the fan button. • Dry Mode Choose dry mode to remove excess moisture from the air during periods of high humidity. All water pulled from the air will condense inside the appliance and drain out the back. The fan speed will be automatically set and cannot be modified in dry mode. • Fan Mode Choose fan mode to run the internal fan without engaging the cooling function. Press the fan button repeatedly to choose the fan speed. • Auto Mode Auto mode is a pre-set factory program that automatically defines the mode and fan speed based on the set temperature, the ambient temperature and the ambient humidity. UP AND DOWN ARROWS The up and down arrows will modify the set temperature in 1° increments. The up and down arrows will modify the set time of the timer function in 0.5 hour increments up to 10 hours and then in 1 hour increments up to 24 hours maximum. 11 OPERATING INSTRUCTIONS SLEEP FOLLOW ME The sleep function can be used to conserve energy during sleeping hours. There is a temperature sensor built into the remote control that will monitor the room temperature. Keep the remote control with you and the appliance will automatically adjust the set temperature based on the temperature where you are located. When selected, the set temperature will increase by 1°C/2°F every half hour for one full hour. The appliance will hold the new set temperature for 6 hours before automatically returning to normal operation. The remote will display the temperature at its location. The remote will send a signal to the air conditioner every 3 minutes, so long as you remain within range of the appliance. The Sleep Function can be canceled at any time by pressing the Sleep Button. ENERGY SAVER The energy saver function will automatically cycle the fan on and off when the compressor is not in use to minimize how often the compressor needs to turn on. When selected, the fan will continue to run for 3 minutes after the compressor turns off. The fan will then cycle on for 2 minutes in 10 minute intervals until the ambient temperature is above the set temperature, at which point the compressor will turn on and cooling will resume. The follow me light on the control panel will illuminate for 5 seconds every 3 minutes to indicate that it has received a signal from the remote. If the appliance does not receive a signal from the remote during any 7 minute interval it will beep to indicate that the follow me mode has ended. The maximum distance for the follow me feature is 8 meters (26 feet). This feature is available in cool and auto modes. WIRELESS CONNECTION This appliance can be controlled with a wireless application on your wireless device. Visit https://www.danby.com/support/#apps to download the application and learn about its operation. 12 OPERATING INSTRUCTIONS TIMER Using On and Off Timers Simultaneously The timer can be used to turn the appliance on or off after a set period of time. The on and off timers can be used at the same time. The control panel has one timer button. Press once to set the auto off timer and twice to set the auto off timer. The remote control has separate timer on and timer off buttons. Auto On Timer 1. Press the timer on button on the remote or press the timer button on the control panel twice. 2. Use the up and down arrows to select the desired amount of time before the appliance should turn on. 3. Use the mode button to select the desired mode. 4. Use the fan button to select the desired fan speed. 5. The time selected will appear on the display panel and will count down until the appliance turns on. Auto Off Timer To set the appliance to turn on, run for a set period of time and then turn off, set the auto on timer first and then set the auto off timer. To set the appliance to run for a period of time, turn off for a period of time and then turn back on, set the auto off timer first and then set the auto on timer. Both indicator lights will illuminate and the display will count down to the appliance either turning off or on, whichever function was set first. The timer will not cycle the appliance on and off indefinitely. The on and off timers will function one time and then the appliance will return to regular functioning. Turning the appliance off or unplugging the appliance will clear all memory settings, including the timer. 1. Press the timer off button on the remote or press the timer button on the control panel once. 2. Use the up and down arrows to select the desired amount of time before the appliance should turn off. The appliance will run in the currently selected mode. 3. The time selected will appear on the display panel and will count down until the appliance turns off. 13 CARE & MAINTENANCE AIR FILTER CLEANING The air filter should be cleaned approximately every 2 weeks. The air filter may require more frequent cleaning if there is significant dander or fur in the air. To avoid possible electric shock, ensure that the appliance is unplugged before performing any cleaning or maintenance. Approximately every two weeks, the filter indicator light on the control panel will illuminate as a reminder to clean the filter. Follow the steps below to clean the filter and return the appliance to normal functioning. 1. The air filter is located behind the front intake grill. To remove the air filter, grasp the filter tab on the right side of the grill and slide it out to the right. If the front intake grill has two indents, pull the grill forward to remove the air filter. 2. Use a vacuum cleaner with a soft brush attachment to remove any large debris or dust build up from the air filter. 3. Wash the filter in lukewarm, soapy water, below 40°C (104°F), or use a neutral cleaning agent. 4. Rinse the filter with clean water and dry thoroughly before reinstalling in the appliance. 5. Press the filter button on the control panel to resume normal functioning. Note: Do not operate the appliance without the air filter installed. ERROR CODES If the display panel shows any of the below error codes, unplug the appliance, let it stand for 5-10 minutes and then plug it back in. If the error persists, call for service. The outside of the appliance can be wiped clean with a soft cloth or with a lukewarm, damp cloth if necessary. Do not use gasoline, benzene, thinner or any other chemicals to clean this appliance as these substances can cause damage to the finish and deformation of plastic parts. Never pour water directly onto the appliance as this will cause deterioration of electrical components and wiring insulation. END OF SEASON CARE Before removing the appliance from service for the year, operate the appliance on high fan mode for half a day to ensure the inside of the appliance is dry. This will help avoid the growth of mold or mildew inside the appliance. Ensure the filter is clean and dry. Store the appliance covered in a dry location. Note: When installing or removing the appliance from the window, ensure that caution is taken to prevent it from falling backward. It is recommended that installation or removal is completed with assistance to prevent injury to persons or damage to property or the appliance. DISPOSAL Check for local regulatory compliance regarding approved and safe disposal of this appliance. AS - Room temperature sensor error HS - Electric heating sensor error . - Evaporator temperature sensor error 14 TROUBLESHOOTING Danby Consumer Care: 1-800-263-2629 or [email protected] Hours of operation: Monday to Thursday 8:30 am - 6:00 pm Eastern Standard Time Friday 8:30 am - 4:00 pm Eastern Standard Time Information in this manual is subject to change without notice. PROBLEM POSSIBLE CAUSE Appliance will not operate • Plug is not fully inserted into the wall outlet Insufficient cooling • Blown fuse or circuit breaker • Air filter is dirty • Blocked air flow Noise Odors Water dripping inside Water dripping outside Frost build up • Appliance size is too small for application • Inadequate support in window installation • Formation of mold or mildew on internal wet surfaces • Place an algaecide tablet in base pan; push the tablet through the grill on either side of the appliance • Appliance is not properly angled to allow water to drain to the outside • On very hot or humid days dripping water from the back of the appliance is normal • When outdoor temperatures are below 18.3°C (65°F) frost may form when the appliance is in cooling mode • Switch the appliance to fan only mode until the frost melts This Class B digital apparatus complies with the Canadian ICES-003 standard. CAN ICES-3 (B) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 1. Reorient or relocate the receiving antenna. 2. Increase the separation between the equipment and receiver. 3. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 4. Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not approved by the party responsible for FCC compliance could void the user’s authority to operate the equipment. This appliance complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause interference. 2. This device must accept any interference received, including interference that may cause undesired operation. 15 LIMITED IN-HOME WARRANTY LIMITED “CARRY APPLIANCE IN” WARRANTY This quality product is warranted to be free from manufacturer’s defects in material and workmanship, provided that the unit is used under the normal operating conditions by the manufacturer.to be free from manufacturer’s defects in material and workmanship, provided that the unit is used This qualityintended product is warranted under the normal operating conditions intended manufacturer. This warranty is available only to the person to whom the unitbywasthe originally sold by Danby Products Limited (Canada) or Danby Products Inc. (U.S.A.) (hereafter This warranty is authorized availabledistributor only to of the person whom the unit was originally sold by Danby Products Limited (Canada) or Danby “Danby”) or by an Danby, and istonon-transferable. Products Inc. (U.S.A.) (hereafter “Danby”) or by an authorized distributor of Danby, and is non-transferable. TERMS OF WARRANTY TERMS OF WARRANTY Plastic are warranted for(30) thirty (30)from days fromdate, the with datenoofextensions purchase, with no extensions provided. Plastic parts parts, are warranted for thirty days only purchase provided. First 24 months First Year During the first twenty four (24) months, any functional parts of this product found to be defective, will be repaired the firstattwelve (12) months, any functional of thistoproduct found topurchaser. be defective, will be repaired or replaced, at warrantor’s orDuring replaced, warrantor’s option, at no parts charge the original option, at no charge to the ORIGINAL purchaser. To obtain service To obtain Service Contact the dealer where the unit was purchased, or contact the nearest authorized Danby service depot, where service must be by boundaries a qualified technician. If service performed on Depot. the unit other Danby reserves theperformed right to limit the of “Inservice Home Service” to the proximity of anisAuthorized Service Anybyappanyoneliance than an authorized depot, all obligations of Danby warrantyresponsibility shall be void. requiring service outsideservice the limited boundaries of “In Home Service” , itunder will be this the consumer’s to transport the appliance (at their own expense) to the original retailer (point of purchase) or a service depot for repair. See “Boundaries of In Home Serv ice” below. It Contact is the responsibility theyour purchaser to transport the appliance the nearest depot. your dealer from of whom unit was purchased, or contact your nearest to authorized Danby authorized service depot, service where service must be performed by a qualified service technician. If service is performed the unitslocation by anyoneare othernot thanprotected an authorized depot, or theand unit isare usedthe for responsibility commercial appli of thecation, all Transportation charges to and from theonservice byservice this warranty purchaser. obligations of Danby under this warranty shall be void. Nothing within this warranty shall imply that Danby will be responsible or liable for any spoilage or damage to food or other Boundaries If the appliance a location 100 appliance, kilometers (62 miles) morewhether from the nearest service center your unit must be contents ofofthis appliance, whetheris installed due to inany defectthat ofisthe or itsoruse, proper or improper. In Home Service delivered to the nearest authorized Danby Service Depot, as service must only be performed by a technician qualified and certif ied for warranty service by Danby. Transportation charges EXCLUSIONS to and from the service location are not protected by this warranty and are t he responsibility of thethere purchaser. Save as herein provided, by Danby, are no other warranties, conditions, representations or guarantees, express or implied, made or intended by Danby or its authorized distributors and all other warranties, conditions, representations or guarantees, including any warranties, conditions, or will guarantees under anyforSale of Goods Act or like or legislation statuteof is expressly Nothing within this warrantyrepresentations shall imply that Danby be responsible or liable any spoilage or damage to food other c orontents thishereby appliance, whether due excluded. hereinorprovided, Danby not be responsible for any damages to persons or property, including the unit itself, to any defectSave of theas appliance, its use, whether propershall or improper. howsoever caused or any consequential damages arising from the malfunction of the unit and by the purchase of the unit, the purchaser does hereby agree to indemnify and hold harmlessEXCLUSIONS Danby from any claim for damages to persons or property caused by the unit. Save as herein provided, Danby, there are no other warranties, conditions, representations or guarantees, express or implied, m ade or intended by Danby or its authorized distributors and all other warranties, conditions, representations or guarantees, including any warranties, conditio ns, representations or guarantees GENERAL PROVISIONS under any Sale of Goods Act or like legislation or statue is hereby expressly excluded. Save as herein provided, Danby shall no t be responsible for any damages No warranty or insurance herein contained or set out shall apply when damage or repair is caused by any of the following: to persons or property, including the unit itself, howsoever caused or any consequential damages arising from the malfunction o f the unit and by the purchase of 1) Power failure. the unit, the purchaser does hereby agree to indemnify and hold harmless Danby from any claim for damages to persons or propert y caused by the unit. 2) Damage in transit or when moving the appliance. 3) Improper power supply such as low voltage, defective house wiring or inadequate fuses. 4) Accident, alteration, abuse or misuse of the appliance GENERAL such asPROVISIONS inadequate air circulation in the room or abnormal operating conditions extremely high or low room temperature). No warranty(ie. or insurance herein contained or set out shall apply when damage or repair is caused by any of the following: 5) Use1)forPower commercial failure. or industrial purposes (ie. If the appliance is not installed in a domestic residence). 6) Fire, water damage, theft, war, riot, hostility, acts of God such as hurricanes, floods etc. 2) Damage in transit or when moving the appliance. 7) Service calls resulting in customer education. 3) Improper power supply such as low voltage, defective house wiring or inadequate fuses.an appliance outdoors that is not approved for outdoor 8) Improper Installation (ie. Building-in of a free standing appliance or using 4) Accident, alteration, or misuseto: of the appliancepatios, such as inadequate air circulation in the or abnormal operating con or climate ditions controlled). application, including but abuse not limited garages, porches or anywhere thatroom is not properly insulated (extremely high or low room temperature). Proof of date will be required for(ie.warranty claims; of sale.residence). In the event that warranty service is required, present 5) purchase Use for commercial or industrial purposes If the appliance is not retain installedbills in a domestic the proof of purchase to our service 6) Fire, water damage, theft,authorized war, riot, hostility, acts ofdepot. God such as hurricanes, floods etc. 7) Service calls resulting in customer education. 8) Improper Installation (ie. Building-in of a free standing appliance or using an appliance outdoors that is not approved for out door application). Proof of purchase date will be required for warranty claims; so, please retain bills of sale. In the event warranty service is required, present this document to our AUTHORIZED SERVICE DEPOT. Warranty Service Warranty Service In-home Carry In Danby Products Limited Danby Products Limited PO 1778, Guelph, Ontario, N1H 6Z9 POBox Box 1778, Guelph, Ontario, Canada N1H Canada 6Z9 Telephone: (519) 837-0920 FAX: (519) 837-0449 Telephone: (519) 837-0920 FAX: (519) 837-0449 1-800-263-2629 1-800-263-2629 04/17 04/09 Danby Products Danby Products Inc. Inc. PO Box PO 669, Findlay, U.S.A. Box 669, Findlay,Ohio, Ohio, U.S.A. 45840 45840 Telephone: Telephone: (419) 425-8627 (419) 425-8629 (419) 425-8627 FAX: FAX: (419) 425-8629 Bienvenue Bienvenue à la famille Danby. Nous sommes fiers de la qualité de nos produits et nous croyons en le service fiable. Nous vous suggérons de lire ce manual d’utilisation avant de brancher votre nouvel appareil car il contient des informations inportantes sur l’utilisation, la sécurité, le dépannage et la maintenance, afin d’assurer la fiabilité et la longévité de votre appareil. Visitez www.Danby.com pour accéder aux outils d’autoservice, aux FAQ et bien plus encore. Pour obtenir de l’aide supplémentaire, composez 1-800-263-2629. Notez les informations ci-dessous; Vous aurez besoin de cette information pour obtenir un service sous garantie. Vous devez fournir le reçu d’achat original pour valider votre garantie et recevoir le service. Numéro de modèle: _____________________________________________ Numéro de serie: _______________________________________________ Date d’achat: __________________________________________________ Besoin d’assistance? Avant d’appeler pour service, voici quelques choses que vous pouvez faire pour nous aider à mieux vous servir. Lire ce manuel du propriétaire: Il contient des instructions pour vous aider à utiliser et à maintenir votre appareil correctement. Si vous recevez un appareil endommagé: Contactez immédiatement le revendeur ou l’entrepreneur qui vous a vendu l’appareil. Gagnez du temps et de l’argent: Avant d’appeler pour service, consultez la section de dépannage à la fin de ce manuel. Cette section vous aidera à résoudre les problèmes courants pouvant survenir. 1-800-26- Danby (1-800-263-2629) 17 Consignes de sécurité importantes LIRE ET SUIVRE TOUTES LES INSTRUCTIONS DE SÉCURITÉ EXIGENCES DE SÉCURITÉ INSTRUCTIONS DE MISE À LA TERRE DANGER: Risque d’incendie ou d’explosion. Fluide frigorigène inflammable utilisé. Ne pas endommager le circuit de réfrigérant. Cet appareil doit être mis à la terre. La mise à la terre réduit le risque de choc électrique en fournissant un fil d’échappement pour le courant électrique. • Assurez-vous que les réparations sont effectuées par du personnel autorisé par l’usine, afin de minimiser les dommages au produit ou les problèmes de sécurité. • Consultez le manuel de réparation ou le guide du propriétaire avant de tenter de réparer ce produit. Toutes les précautions de sécurité doivent être suivies. • Éliminer correctement conformément aux réglementations fédérales ou locales. • Suivez attentivement les instructions de manipulation. • Veillez à ce que les ouvertures de ventilation de l’appareil ne soient pas obstruées. • N’utilisez pas d’appareils mécaniques ou d’autres moyens pour accélérer le processus de dégivrage. • Les enfants doivent être surveillés pour s’assurer qu’ils ne jouent pas avec l’appareil. • Ne rangez pas et n’installez pas l’appareil à proximité de sources d’allumage fonctionnant en continu, telles que des flammes nues ou une cuisinière à gaz. • Ne pas utiliser près de l’eau ou dans une pièce humide. • Ne pas percer ou brûler. • Sachez que les réfrigérants peuvent ne pas contenir d’odeur. • L’appareil doit être rangé de manière à éviter tout dommage mécanique. Tout le câblage doit être conforme aux codes locaux et nationaux et doit être installé par un électricien qualifié. Vérifiez l’alimentation disponible et résolvez tout problème de câblage avant d’installer et d’utiliser cet appareil. Cet appareil possède un cordon doté d’un fil de mise à la terre avec une fiche à 3 broches. Le cordon d’alimentation doit être branché sur une prise correctement mise à la terre. Si la sortie est une prise murale à 2 broches, elle doit être remplacée par une prise murale à 3 broches correctement mise à la terre. La plaque signalétique en série indique la tension et la fréquence auxquelles l’appareil est conçu. AVERTISSEMENT - Une utilisation incorrecte de la fiche de mise à la terre peut entraîner un risque d’électrocution. Consultez un électricien qualifié ou un agent de service si les instructions de mise à la terre ne sont pas complètement comprises ou s’il existe un doute quant à savoir si l’appareil est correctement mis à la terre. Ne branchez pas votre appareil à des rallonges ou avec un autre appareil dans la même prise murale. Ne pas épisser le cordon d’alimentation. Ne coupez ou retirez en aucun cas la troisième broche du cordon d’alimentation. N’utilisez pas de cordons de prolongement ou d’adaptateurs sans mise à la terre (deux broches). Si le cordon d’alimentation est endommagé, il doit être remplacé par le fabricant, son agent de service ou une personne qualifiée similaire afin d’éviter tout risque. La plaque signalétique située sur le côté droit de l’appareil, juste au-dessus du cordon d’alimentation, contient des données électriques et techniques. Cet appareil n’est pas destiné à être utilisé par des personnes (y compris des enfants) dont les capacités physiques, sensorielles ou mentales peuvent être différentes ou réduites, ou qui manquent d’expérience ou de connaissances, à moins que ces personnes ne soient supervisées ou formées pour faire fonctionner l’appareil par une personne responsable de leur utilisation. sécurité. ATTENTION: RISQUE D’INCENDIE Fluide frigorigène inflammable utilisé. Lors de l’entretien ou de la mise au rebut du climatiseur, le réfrigérant ne doit pas pouvoir s’échapper à l’air libre. GARDEZ CES INSTRUCTIONS! 18 Consignes de sécurité importantes LIRE ET SUIVRE TOUTES LES INSTRUCTIONS DE SÉCURITÉ Toute personne impliquée dans le travail sur le circuit de fluide frigorigène doit détenir un certificat en cours de validité, délivré par une autorité d’évaluation accréditée du secteur, attestant de sa compétence pour manipuler les fluides frigorigènes en toute sécurité, conformément à une spécification d’évaluation reconnue par l’industrie. L’entretien ne doit être effectué que selon les recommandations du fabricant. L’entretien et les réparations nécessitant l’assistance d’un autre personnel qualifié doivent être effectués sous la supervision de la personne compétente pour l’utilisation de réfrigérants inflammables. Lors de l’entretien ou de la mise au rebut de l’appareil, le réfrigérant doit être récupéré correctement et ne doit pas être autorisé à se décharger directement dans l’air. Informations sur le service 1. Chèques à la région: Avant de commencer à travailler sur des systèmes contenant des frigorigènes inflammables, des contrôles de sécurité sont nécessaires pour réduire au minimum le risque d’inflammation. Pour réparer le système de réfrigération, les précautions suivantes doivent être respectées avant de procéder à des travaux sur le système. 2. Procédure de travail: Les travaux doivent être effectués selon une procédure contrôlée, de manière à minimiser le risque de présence de gaz ou de vapeurs inflammables pendant l’exécution des travaux. 3. Zone de travail générale: Tout le personnel de maintenance et les autres personnes travaillant dans la zone locale doivent être informés de la nature des travaux effectués. Les travaux dans des espaces confinés doivent être évités. La zone autour de l’espace de travail doit être divisée. Assurez-vous que les conditions dans la zone de travail ont été sécurisées en retirant tout matériau inflammable. 4. Vérification de la présence de réfrigérant: Le sont doivent être vérifiés avec un détecteur de réfrigérant approprié avant et pendant le travail pour s’assurer que le technicien est conscient des atmosphères potentiellement inflammables. Assurez-vous que l’équipement de détection des fuites utilisé convient aux fluides frigorigènes inflammables, c’est-à-dire qu’il ne produit pas d’étincelles, est correctement scellé et de sécurité intrinsèque. 5. Présence d’extincteur: Si des travaux à chaud doivent être effectués sur l’équipement de réfrigération ou sur toute pièce associée, un équipement d’extinction d’incendie approprié doit être disponible. Avoir un extincteur à poudre sèche ou au C02 adjacent à la zone de travail. 6. Aucune source d’inflammation: Aucune personne effectuant des travaux en rapport avec un système de réfrigération impliquant l’exposition de tuyauteries contenant ou ayant contenu un réfrigérant inflammable ne doit utiliser une source d’inflammation de manière à entraîner un risque d’incendie ou d’explosion. Toutes les sources d’inflammation possibles, y compris le tabagisme, doivent être suffisamment éloignées du lieu d’installation, de réparation, de retrait et d’élimination, pendant lesquelles un réfrigérant inflammable peut éventuellement être rejeté dans l’espace environnant. Avant le début des travaux, la zone autour de l’équipement doit être inspectée pour s’assurer qu’il n’y a pas de danger d’inflammabilité ou de risque d’inflammation. Aucun signe de fumer ne doit être affiché. 7. Zone ventilée: Assurez-vous que la zone est à l’air libre ou qu’elle est correctement ventilée avant de pénétrer dans le système ou d’effectuer des travaux à chaud. Une certaine ventilation doit être maintenue pendant la durée des travaux. La ventilation doit disperser en toute sécurité tout fluide réfrigérant libéré et de préférence l’expulser de l’extérieur vers l’atmosphère. 8. Contrôles à l’équipement de réfrigération: Lorsque des composants électriques sont remplacés, ils doivent être adaptés à l’usage prévu et aux spécifications appropriées. Respectez à tout moment les directives du fabricant en matière d’entretien et de maintenance. En cas de doute, consultez le service technique du fabricant. 19 Consignes de sécurité importantes LIRE ET SUIVRE TOUTES LES INSTRUCTIONS DE SÉCURITÉ Les contrôles suivants doivent être appliqués aux installations utilisant des réfrigérants inflammables: Réparation de composants scellés • La taille de la charge est conforme à la taille de la pièce dans laquelle les pièces contenant le réfrigérant sont installées. • Les machines de ventilation et les sorties fonctionnent de manière adéquate et ne sont pas obstruées. • Si un circuit de réfrigération indirect est utilisé, le circuit secondaire doit être vérifié pour la présence de réfrigérant. • Le marquage sur l’équipement continue d’être visible et lisible. Les marques et les signes qui deviennent illisibles doivent être corrigés. • Les tuyaux ou composants de réfrigération sont installés dans une position où ils ne risquent pas d’être exposés à une substance susceptible de corroder les composants contenant du réfrigérant, à moins que les composants ne soient construits avec des matériaux intrinsèquement résistants à la corrosion ou protégés de manière adéquate. 9. Contrôles aux appareils électriques: La réparation et la maintenance des composants électriques doivent inclure les contrôles de sécurité initiaux et les procédures d’inspection des composants. S’il existe un défaut susceptible de compromettre la sécurité, aucune alimentation électrique ne doit être connectée au circuit jusqu’à ce que le problème soit résolu. Si le défaut ne peut pas être corrigé immédiatement mais qu’il est nécessaire de poursuivre le fonctionnement, une solution temporaire adéquate doit être utilisée. Cela doit être signalé au propriétaire de l’équipement afin que toutes les parties soient informées. 1. Lors de la réparation de composants scellés, toutes les alimentations électriques doivent être débranchées de l’équipement utilisé avant toute dépose de couvercles scellés, etc. S’il est absolument nécessaire de prévoir une alimentation électrique de l’équipement pendant l’entretien, une détection des fuites fonctionnant en permanence doit être situé au point le plus critique pour avertir d’une situation potentiellement dangereuse. 2. Afin de garantir qu’en manipulant des composants électriques, le boîtier ne soit pas modifié de telle sorte que le niveau de protection soit affecté, une attention particulière doit être accordée aux éléments suivants: • Dommages aux câbles, nombre excessif de connexions, bornes non conformes aux spécifications d’origine, dommages aux joints, mauvais montage des presse-étoupes, etc. • Assurez-vous que l’appareil est bien monté. • Assurez-vous que les joints ou les matériaux d’étanchéité ne se sont pas dégradés de telle sorte qu’ils ne servent plus à empêcher la pénétration d’atmosphères inflammables. Les pièces de rechange doivent être conformes aux spécifications du fabricant. Remarque: l’utilisation d’un produit d’étanchéité à base de silicone peut nuire à l’efficacité de certains types d’équipement de détection de fuites. Les composants de sécurité intrinsèque ne doivent pas nécessairement être isolés avant de travailler dessus. Réparation de composants à sécurité intrinsèque Les contrôles de sécurité initiaux doivent inclure: • Que les condensateurs sont déchargés. Ceci doit être fait de manière sûre pour éviter la possibilité d’étincelles. • Qu’aucun composant ni câblage électrique sous tension ne soit exposé pendant le chargement, la récupération ou la purge du système. • Qu’il existe une continuité de la mise à la terre. N’appliquez aucune charge inductive ou capacitive permanente sur le circuit sans vous assurer que cela ne dépassera pas la tension et le courant autorisés pour l’équipement utilisé. Les composants à sécurité intrinsèque sont les seuls types sur lesquels on peut travailler tout en vivant dans une atmosphère inflammable. L’appareil d’essai doit avoir la cote correcte. Remplacez les composants uniquement par des pièces spécifiées par le fabricant. D’autres pièces peuvent provoquer l’inflammation de réfrigérant dans l’atmosphère par une fuite. 20 Consignes de sécurité importantes LIRE ET SUIVRE TOUTES LES INSTRUCTIONS DE SÉCURITÉ Le câblage Enlèvement et évacuation Vérifiez que le câblage ne sera pas soumis à l’usure, à la corrosion, à une pression excessive, aux vibrations, aux arêtes vives ou à tout autre effet néfaste sur l’environnement. La vérification doit également prendre en compte les effets du vieillissement ou des vibrations continuelles provenant de sources telles que les compresseurs ou les ventilateurs. Lorsque vous pénétrez dans le circuit de fluide frigorigène pour effectuer des réparations ou à toute autre fin, vous devez utiliser des procédures classiques. Cependant, il est important que la meilleure pratique soit suivie car l’inflammabilité est une considération. Les procédures suivantes doivent être respectées: Détection de réfrigérants inflammables En aucun cas, des sources d’inflammation potentielles ne doivent être utilisées pour rechercher ou détecter des fuites de réfrigérant. Une lampe à incandescence ou tout autre détecteur utilisant une flamme nue ne doit pas être utilisé. Méthodes de détection de fuite Les méthodes de détection des fuites suivantes sont jugées acceptables pour les systèmes contenant des réfrigérants inflammables: • Des détecteurs de fuites électroniques doivent être utilisés pour détecter les réfrigérants inflammables, mais la sensibilité peut ne pas être adéquate ou nécessiter un réétalonnage. L’équipement de détection doit être étalonné dans une zone sans réfrigérant. Assurez-vous que le détecteur n’est pas une source potentielle d’inflammation et qu’il convient au réfrigérant utilisé. • L’équipement de détection de fuites doit être réglé sur un pourcentage de la LF du réfrigérant et doit être calibré avec le réfrigérant utilisé et le pourcentage de gaz approprié (25% maximum) est confirmé. • Les fluides de détection des fuites peuvent être utilisés avec la plupart des réfrigérants, mais l’utilisation de détergents contenant du chlore doit être évitée car le chlore peut réagir avec le réfrigérant et corroder le cuivre ou les tuyauteries. • Si une fuite est suspectée, toutes les flammes nues doivent être supprimées ou éteintes. • Si une fuite de réfrigérant nécessitant un brasage est détectée, tout le réfrigérant doit être récupéré du système ou isolé au moyen de vannes d’arrêt dans une partie du système éloignée de la fuite. L’azote libre d’oxygène (OFN) doit ensuite être purgé à travers le système avant et pendant le processus de brasage. • • • • • • Retirer le réfrigérant. Purger le circuit avec du gaz inerte. Évacuer. Purger à nouveau avec un gaz inerte. Ouvrir le circuit en coupant ou en soudant. La charge de réfrigérant doit être récupérée dans les bonnes bouteilles de récupération. Le système doit être rincé avec OFN pour sécuriser l’unité. Ce processus peut avoir besoin d’être répété plusieurs fois. L’air comprimé ou l’oxygène ne doit pas être utilisé pour cette tâche. • Le rinçage doit être réalisé en rompant le vide dans le système avec OFN et en continuant à se remplir jusqu’à atteindre la pression de travail, puis en relâchant dans l’atmosphère et en tirant finalement vers le vide. Ce processus doit être répété jusqu’à ce qu’il n’y ait plus de réfrigérant dans le système. Lorsque la dernière charge OFN est utilisée, le système doit être purgé à la pression atmosphérique pour permettre le travail. Cette opération est absolument essentielle si des opérations de brasage sur la tuyauterie doivent avoir lieu. • Assurez-vous que la sortie de la pompe à vide ne se trouve pas à proximité de sources d’inflammation et qu’il existe une ventilation. Procédures de charge Outre les procédures de chargement classiques, les exigences suivantes doivent être respectées: • Assurez-vous que les différents réfrigérants ne soient pas contaminés lors de l’utilisation d’un équipement de charge. Les tuyaux ou les conduites doivent être aussi courts que possible pour minimiser la quantité de réfrigérant qu’ils contiennent. • Les bouteilles doivent être maintenues debout. • Assurez-vous que le système de réfrigération est mis à la terre avant de le charger avec du réfrigérant. • Étiquetez le système lorsque le chargement est terminé, s’il ne l’est pas déjà. • Un soin extrême doit être pris pour ne pas trop remplir le système de réfrigération. • Avant de recharger le système, il doit être testé sous pression avec OFN. Le système doit être soumis à un test d’étanchéité à la fin du chargement mais avant la mise en service. Un contrôle d’étanchéité doit être effectué avant de quitter le site. 21 Consignes de sécurité importantes LIRE ET SUIVRE TOUTES LES INSTRUCTIONS DE SÉCURITÉ Déclassement Récupération Avant d’effectuer cette procédure, il est essentiel que le technicien connaisse parfaitement l’équipement dans tous ses détails. Il est recommandé, conformément aux bonnes pratiques, que tous les réfrigérants soient récupérés en toute sécurité. Avant l’exécution de la tâche, un échantillon d’huile et de réfrigérant doit être prélevé au cas où une analyse serait nécessaire avant de réutiliser le réfrigérant récupéré. Il est essentiel que l’alimentation électrique soit disponible avant le début de la tâche. Lorsque vous retirez du fluide frigorigène d’un système, que ce soit pour un entretien ou une mise hors service, il est recommandé de procéder à l’élimination de tous les fluides frigorigènes en toute sécurité. A. Familiarisez-vous avec l’équipement et son fonctionnement. B. Isoler le système électriquement. C. Avant de tenter la procédure, assurez-vous que: • Un équipement de manutention mécanique est disponible si nécessaire pour la manipulation des bouteilles de réfrigérant. • Tous les équipements de protection individuelle sont disponibles et utilisés correctement. • Le processus de récupération est supervisé à tout moment par une personne compétente. • L’équipement de récupération et les bouteilles sont conformes aux normes appropriées. D. Pomper le système de réfrigérant, si possible. E. Si le vide n’est pas possible, créez un collecteur afin que le réfrigérant puisse être éliminé de différentes parties du système. F. Assurez-vous que le cylindre est situé sur la balance avant la récupération. G. Démarrez la machine de récupération et utilisezla conformément aux instructions du fabricant. H. Ne pas trop remplir les bouteilles. Pas plus de 80% de volume de charge liquide. I. Ne dépassez pas la pression de service maximale du cylindre, même temporairement. J. Lorsque les bouteilles ont été remplies correctement et que le processus est terminé, assurez-vous que les bouteilles et l’équipement sont retirés du site rapidement et que toutes les vannes d’isolement de l’équipement sont fermées. K. Le réfrigérant récupéré ne doit pas être chargé dans un autre système de réfrigération à moins d’avoir été nettoyé et vérifié. Étiquetage L’équipement doit porter une étiquette indiquant qu’il a été mis hors service et vidé du réfrigérant. L’étiquette doit être datée et signée. Assurez-vous qu’il y a des étiquettes sur l’équipement indiquant que celui-ci contient du réfrigérant inflammable. Lors du transfert du réfrigérant dans les bouteilles, assurez-vous que seul le récupérateur approprié récupère les bouteilles. Assurez-vous que le nombre correct de cylindres permettant de contenir la charge totale du système est disponible. Tous les cylindres à utiliser sont conçus pour le réfrigérant récupéré et étiquetés pour ce réfrigérant, c’est-àdire des cylindres spéciaux pour la récupération du réfrigérant. Les bouteilles doivent être équipées d’une soupape de surpression et des vannes d’arrêt associées en bon état de fonctionnement. Les bouteilles de récupération vides sont évacuées et, si possible, refroidies avant la récupération. L’équipement de récupération doit être en bon état de fonctionnement, avec un ensemble d’instructions concernant l’équipement disponible et doit être adapté à la récupération des réfrigérants inflammables. En outre, un jeu de balances étalonnées doit être disponible et en bon état de fonctionnement. Les flexibles doivent être complets avec des raccords débranchés sans fuite et en bon état. Avant d’utiliser la machine de récupération, vérifiez qu’elle est en bon état de fonctionnement, correctement entretenue et que tous les composants électriques associés sont scellés pour éviter toute inflammation en cas de fuite du réfrigérant. Consultez le fabricant en cas de doute. Le fluide frigorigène récupéré doit être renvoyé au fournisseur de fluide frigorigène dans la bouteille de récupération appropriée et la note de transfert de déchets correspondante doit être préparée. Ne mélangez pas les réfrigérants dans les unités de récupération et en particulier dans les bouteilles. Si des compresseurs ou des huiles de compresseurs doivent être éliminés, assurez-vous qu’ils ont été évacués à un niveau acceptable pour vous assurer que le réfrigérant inflammable ne reste pas dans le lubrifiant. Le processus d’évacuation doit être effectué avant de renvoyer le compresseur aux fournisseurs. Seul un chauffage électrique du corps du compresseur doit être utilisé pour accélérer ce processus. Lorsque l’huile est vidangée d’un système, elle doit être effectuée en toute sécurité. 22 INSTRUCTIONS D’INSTALLATION EMPLACEMENT OUTILS REQUIS Ce climatiseur est conçu pour les fenêtres simples ou doubles. Étant donné que la conception des fenêtres varie, il peut être nécessaire d’apporter certaines modifications pour une installation en toute sécurité. • Tournevis: Phillips et tête plate. • Perceuse électrique: 3,2 mm (1/8 po.) de diamètre • Crayon • Mètre ruban • Les ciseaux • Niveau du charpentier Ce climatiseur n’est pas conçu pour les fenêtres verticales du type à glissière ni pour l’installation «à travers le mur». Assurez-vous que la fenêtre et le cadre sont structurellement sains et exempts de bois sec ou pourri. Installez le climatiseur dans une fenêtre sur un côté du bâtiment qui favorise plus d’ombre que de soleil. Si l’appareil doit être à la lumière directe du soleil, il est conseillé de prévoir un store pare-soleil pour assurer un fonctionnement efficace. N’installez pas l’appareil si une fuite de gaz combustible est suspectée. Cet appareil est conçu pour évaporer la condensation dans des conditions normales. Dans des conditions extrêmement chaudes ou humides, un excès de condensation peut déborder vers l’extérieur. L’appareil doit être installé à un endroit où la condensation ne peut pas goutter sur les piétons ou les propriétés voisines. ACCESSOIRES Les accessoires suivants sont inclus avec l’appareil et doivent être utilisés pendant l’installation. 1. Vis de 13 mm (1/2 po) (x7) 2. Vis de 9,5 mm (3/8 pouce) (x4) (installées en usine sur certains modèles). 3. Verrouillage de sécurité 4. Joint de mousse adhésif 5. Joint en mousse régulière 6. Support de montage en forme de «L» (installé en usine sur certains modèles.) 7. Support pour fenêtres en bois (x2) 8. Support pour fenêtres en vinyle (x2) 9. Coupe-froid (x5) 10. Rideaux latéraux (x2) 2 1 Laissez un espace suffisant autour de l’appareil pour permettre une circulation d’air suffisante. L’arrière de l’appareil doit être à l’extérieur, pas dans un garage ni dans une autre pièce. Maintenez l’appareil à l’écart des obstacles et à au moins 76 cm (30”) du sol. Assurez-vous que les rideaux et autres obstructions ne bloquent pas le flux d’air vers l’appareil. 4 30.5 po (12 cm) 5 6 7 8 9 10 50.8 cm (20 pouces) 76.2 cm (30 pouces) 50.8 cm (20 pouces) 23 3 INSTRUCTIONS D’INSTALLATION INSTALLATION Vérifiez l’angle d’inclinaison Fixez les rideaux latéraux à l’appareil en faisant glisser le cadre du rideau dans le canal latéral de l’armoire. Les rideaux sont étiquetés «gauche» et «droite sur les cadres. Cela concerne les côtés gauche et droit de l’appareil lorsque vous faites face à l’avant de l’appareil. Le climatiseur doit être incliné vers le bas vers l’extérieur environ 3° à 4°. Cette inclinaison encouragera toute eau condensée à s’écouler vers l’extérieur. Si de l’eau condensée fuit à l’intérieur de la maison, vérifier l’angle d’inclinaison et ajuster si nécessaire. Coupez le joint en mousse ordinaire pour qu’il corresponde à la zone du rebord de la fenêtre sur laquelle le climatiseur reposera. Mesurez l’angle d’inclinaison de l’avant du bord de l’armoire. La différence de hauteur entre l’avant et l’arrière de l’appareil, étiqueté “A” sur l’image ci-dessous, devrait être d’environ 19 mm - 2,5 cm (3/4” - 1”). Placez le climatiseur dans la fenêtre avec le support de montage en forme de «L» placé devant le châssis supérieur. Le bas de l’armoire doit être placé sur la partie en retrait du cadre de la fenêtre. Abaisser le châssis de la fenêtre supérieure jusqu’à ce qu’il repose juste derrière la bride avant du support de montage en forme de «L». A Développez les rideaux latéraux de chaque côté et fixez le haut des cadres au châssis de fenêtre à l’aide d’une vis de 13 mm (1/2”) de chaque côté du support de montage en forme de“ L ”. Fixez les fixations situées sur la partie inférieure de chaque rideau au rebord de la fenêtre à l’aide d’une vis de 13 mm (1/2”) de chaque côté du meuble. Placez le joint en mousse adhésif dans l’ouverture entre les fenêtres intérieure et extérieure et fixez le verrou de sécurité sur le cadre de fenêtre extérieur à l’aide de deux vis de 13 mm (1/2”). L SUPPORT Le support en forme de «L» peut être installé en usine sur certains modèles. Si le support en forme de «L» n’est pas préinstallé, fixez-le au haut de l’armoire comme indiqué cidessous à l’aide des vis fournies de 9,5 mm (3/8”) (x4). 24 INSTRUCTIONS D’UTILISATION PANNEAU DE CONTRÔLE 1. Récepteur de télécommande: Assurez-vous que ce récepteur n’est pas obscurci par des rideaux ou d’autres éléments, car cela pourrait avoir un impact sur le fonctionnement de la télécommande. 2. Suivez-moi voyant: S’allume lorsque la fonction suivez-moi est activée. Suivez-moi ne peut être réglé qu’à partir de la télécommande. 3. Bouton d’alimentation: Utilisé pour allumer ou éteindre l’appareil. 4. Bouton mode: Utilisé pour choisir le mode de fonctionnement. 5. Flèches haut et bas: Utilisé pour ajuster la température réglée par incréments de 1° et la fonction de minuterie en des incréments de 30 minutes jusqu’à 10 heures, puis en incréments de 1 heure jusqu’à 24 heures. 6. Panneau d’affichage: Affiche la température réglée, la température ambiante et les réglages de la minuterie. Pour changer l’échelle de température affichée, appuyez simultanément sur les boutons haut et bas. 7. Bouton ventilateur: Utilisé pour régler la vitesse du ventilateur. Le ventilateur peut être réglé sur Bas, Moyen, Haut et Auto. 8. Bouton de connexion sans fil: Utilisé pour se connecter à un réseau sans fil. 9. Bouton d’économie d’énergie: Utilisé pour définir la fonction économiseur d’énergie. 10. Bouton filtre: Le témoin lumineux s’allume comme un rappel pour vérifier le filtre. Une fois que le filtre a été nettoyé, utilisez ce bouton pour reprendre son fonctionnement. 11. Bouton de sommeil: Utilisé pour régler la fonction sommeil. 12. Bouton de minuterie: Utilisé pour régler la minuterie de marche et arrêt automatique. 2 1 6 3 4 5 8 9 10 7 11 25 12 INSTRUCTIONS D’UTILISATION TÉLÉCOMMANDE 1. Panneau d’affichage: Affiche la température définie, la température ambiante et les réglages de la minuterie. Pour changer l’échelle de température affichée, appuyez sur la touche °C/°F. 1 2. Flèches haut et bas: Utilisé pour ajuster la température réglée par incréments de 1° et la fonction de minuterie en des incréments de 30 minutes jusqu’à 10 heures, puis en incréments de 1 heure jusqu’à 24 heures. 3. Bouton mode: Utilisé pour choisir le mode de fonctionnement. TEMP 4. Bouton de suivez-moi: Utilisé pour définir la fonction suivez-moi. 2 5. Bouton °C/°F: Utilisez pour changer l’échelle de température. 6. Bouton LED: Appuyez sur pour allumer ou éteindre le rétro-éclairage de la LED. 7 3 7. Bouton d’alimentation: Utilisé pour allumer ou éteindre l’appareil. 8. Bouton de dormir: Utilisé pour régler la fonction dormir. 8 4 9. Bouton ventilateur: Utilisé pour régler la vitesse du ventilateur. Le ventilateur peut être réglé sur bas, moyen, haut et auto. 5 10. Bouton minuterie d’allumer: Utilisé pour régler la minuterie d’allumer. 9 10 11 13 11. Bouton minuterie d’éteindre: Utilisé pour régler la minuterie d’éteindre automatique. 6 12. Bouton d’économie d’énergie: Utilisé pour définir la fonction économiseur d’énergie. 13. Bouton de verrouillage: Appuyez simultanément sur les touches °C/°F et la minuterie pour verrouiller la télécommande et éviter que les réglages ne soient modifiés par inadvertance. 26 12 INSTRUCTIONS D’UTILISATION PILES DE LA TÉLÉCOMMANDE MODES DE FONCTIONNEMENT La télécommande nécessite deux piles alcalines AAA (incluses). Les piles doivent être remplacées lorsque: Vous avez le choix entre quatre modes de fonctionnement. Appuyez plusieurs fois sur le bouton de mode pour choisir le mode souhaité. Le voyant adjacent s’allume pour indiquer quel mode a été sélectionné. a) Aucun son n’est entendu lors de la tentative de programmation de l’appareil. b) L’appareil ne répond pas à une commande émise par la télécommande. Remplacement de la batterie: 1. Faites glisser le capot arrière sur la télécommande dans le sens de la flèche. 2. Insérez deux piles AAA suivant la même orientation représentée à l’intérieur de la chambre de la batterie (+/-). • Mode de refroidissement Choisissez le mode refroidissement pour définir la fonction de refroidissement. Utilisez les flèches haut et bas pour choisir la température désirée. Lorsque le mode de refroidissement est sélectionné, la vitesse du ventilateur peut être ajustée en appuyant sur le bouton du ventilateur. • Mode sec 4. Si la télécommande n’est pas utilisée pendant de longues périodes, les piles doivent être retirées. Choisissez le mode sec pour éliminer l’excès d’humidité de l’air pendant les périodes de forte humidité. Toute l’eau extraite de l’air se condensera à l’intérieur de l’appareil et s’écoulera par l’arrière. La vitesse du ventilateur sera automatiquement réglée et ne pourra pas être modifiée en mode sec. Remarques: • Mode ventilateur • Protégez la télécommande contre les températures élevées et évitez l’exposition au rayonnement. Choisissez le mode ventilateur pour faire fonctionner le ventilateur interne sans activer la fonction de refroidissement. Appuyez plusieurs fois sur le bouton du ventilateur pour choisir la vitesse du ventilateur. 3. Réinstallez le capot arrière. • Gardez le récepteur du panneau de contrôle hors de la lumière directe du soleil. • Ne mélangez pas les piles neuves et neuves. • Ne pas mélanger des piles alcalines, standard (carbone-zinc) ou rechargeables (ni-cad, ni-mh, etc.). • La télécommande fonctionne à une distance de 8 mètres (26 pi) du récepteur situé à l’intérieur de l’appareil principal. Toute obstruction entre le récepteur et la télécommande peut provoquer des interférences de signal, ce qui limite la capacité de programmer l’unité principale. • Mode automatique Le mode automatique est un programme d’usine prédéfini qui définit automatiquement le mode et la vitesse du ventilateur en fonction de la température définie, de la température ambiante et de l’humidité ambiante. FLÈCHES HAUT ET BAS Les flèches haut et bas modifieront la température de consigne par incréments de 1°. Les flèches haut et bas modifieront l’heure réglée de la fonction de minuterie par incréments de 0,5 heure jusqu’à 10 heures, puis par incréments d’une heure jusqu’à 24 heures maximum. 27 INSTRUCTIONS D’UTILISATION DORMIR SUIVEZ-MOI La fonction de dormir peut être utilisée pour économiser de l’énergie pendant les heures de dormir. Un capteur de température intégré à la télécommande surveille la température ambiante. Gardez la télécommande avec vous et l’appareil ajustera automatiquement la température de consigne en fonction de la température où vous vous trouvez. Lorsque cette option est sélectionnée, la température définie augmente de 1°C/2°F toutes les demiheures pendant une heure complète. L’appareil maintiendra la nouvelle température réglée pendant 6 heures avant de revenir automatiquement au fonctionnement normal. La télécommande affichera la température à son emplacement. La télécommande envoie un signal au climatiseur toutes les 3 minutes, tant que vous restez à portée de l’appareil. La fonction de dormir peut être annulée à tout moment en appuyant sur le bouton de dormir. Le voyant Follow me du panneau de commande s’allumera pendant 5 secondes toutes les 3 minutes pour indiquer qu’il a reçu un signal de la télécommande. Si l’appareil ne reçoit pas de signal de la télécommande pendant un intervalle de 7 minutes, il émettra un bip pour indiquer que le mode suivez-moi est terminé. ÉCONOMIE D’ÉNERGIE La fonction d’économie d’énergie activera et désactivera automatiquement le ventilateur lorsque le compresseur ne sera pas utilisé afin de minimiser la fréquence à laquelle le compresseur doit s’allumer. Lorsque sélectionné, le ventilateur continuera à fonctionner pendant 3 minutes après la mise hors tension du compresseur. Le ventilateur se met ensuite en marche pendant 2 minutes, par intervalles de 10 minutes, jusqu’à ce que la température ambiante soit supérieure à la température définie. Le compresseur se met alors en marche et le refroidissement reprend. La distance maximale pour la fonction suivez-moi est de 8 mètres (26 pieds). Cette fonctionnalité est disponible en modes cool et auto. CONNEXION SANS FIL Cet appareil peut être contrôlé avec une application sans fil sur votre appareil sans fil. Rendez-vous sur https://www.danby.com/ support/#apps pour télécharger l’application et découvrir son fonctionnement. 28 INSTRUCTIONS D’UTILISATION MINUTERIE La minuterie peut être utilisée pour allumer ou éteindre l’appareil après une période de temps définie. Le panneau de commande a un bouton de minuterie. Appuyez une fois sur cette touche pour régler la minuterie d’extinction automatique et deux fois sur cette touche. La télécommande a des boutons de minuterie activés et désactivés. Fonction allumer automatique 1. Appuyez sur la touche minuterie de la télécommande ou appuyez deux fois sur la touche timer du panneau de commande. 2. Utilisez les flèches vers le haut et vers le bas pour sélectionner la durée souhaitée avant la mise en marche de l’appareil. 3. Utilisez le bouton de mode pour sélectionner le mode souhaité. 4. Utilisez le bouton du ventilateur pour sélectionner la vitesse du ventilateur souhaitée. 5. La durée sélectionnée apparaîtra sur l’écran et comptera jusqu’à ce que l’appareil s’allume. Utilisation simultanée de minuteries allumer et éteindre Les minuteries d’allumer et d’éteindre peuvent être utilisées en même temps. Pour que l’appareil s’allume, lancez-le pendant une durée définie, puis éteignez-le, configurez d’abord la minuterie d’activation automatique, puis définissez la minuterie d’extinction automatique. Pour que l’appareil fonctionne pendant une certaine période, éteignez-le puis rallumez-le, configurez d’abord la minuterie d’éteindre automatique, puis la minuterie d’allume automatique. Les deux voyants s’allumeront et l’affichage indiquera jusqu’à ce que l’appareil s’éteigne ou s’allume, selon la fonction définie en premier. La minuterie ne fera pas allumer et éteindre l’appareil indéfiniment. Les minuteries d’allumage et d’extinction fonctionneront une fois, puis l’appareil retournera à son fonctionnement normal. Le fait d’éteindre ou de débrancher l’appareil efface tous les paramètres de la mémoire, y compris la minuterie. Minuterie d’éteindre automatique 1. Appuyez sur le bouton de minuterie de la télécommande ou appuyez une fois sur le bouton de la minuterie du panneau de commande. 2. Utilisez les flèches vers le haut et vers le bas pour sélectionner la durée souhaitée avant l’extinction de l’appareil. L’appliance fonctionnera dans le mode actuellement sélectionné. 3. La durée sélectionnée apparaîtra sur l’écran et comptera jusqu’à ce que l’appareil s’éteigne. 29 SOINS ET ENTRETIEN FILTRE À AIR NETTOYAGE Le filtre à air doit être nettoyé environ toutes les 2 semaines. Le filtre à air peut nécessiter un nettoyage plus fréquent si il y a un choc important ou de la fourrure dans l’air. Pour éviter tout risque d’électrocution, assurez-vous que l’appareil est débranché avant d’effectuer un nettoyage ou une maintenance. Environ toutes les deux semaines, le voyant du filtre sur le panneau de commande s’allume pour rappeler le nettoyage du filtre. Suivez les étapes cidessous pour nettoyer le filtre et retournez l’appareil au fonctionnement normal. 1. Le filtre à air est situé derrière la grille d’admission avant. Pour retirer le filtre à air, saisissez la languette du filtre sur le côté droit de la grille et glissez-la vers la droite. Si la grille d’admission avant comporte deux retraits, tirez la grille vers l’avant pour retirer le filtre à air. 2. Utilisez un aspirateur avec une brosse douce pour enlever les grands débris ou la poussière du filtre à air. 3. Laver le filtre dans de l’eau tiède savonneuse, inférieure à 40°C (104°F), ou utiliser un agent de nettoyage neutre. 4. Rincez le filtre avec de l’eau propre et séchez bien avant de le réinstaller dans l’appareil. 5. Appuyez sur le bouton de filtre sur le panneau de commande pour reprendre le fonctionnement normal. Remarque: Ne pas utiliser l’appareil sans le filtre à air installé. CODES D’ERREUR Si le panneau d’affichage affiche l’un des codes d’erreur ci-dessous, débranchez l’appareil, laissez reposer pendant 5 à 10 minutes, puis rallumez-le. Si l’erreur persiste, appelez le service. L’extérieur de l’appareil peut être nettoyé avec un chiffon doux ou avec un chiffon tiède et humide si nécessaire. N’utilisez pas d’essence, de benzène, de diluant ou de tout autre produit chimique pour nettoyer cet appareil car ces substances peuvent endommager la finition et la déformation des pièces en plastique. Ne versez jamais d’eau directement sur l’appareil, car cela entraînera une détérioration des composants électriques et de l’isolation des câbles. SOINS POUR LA FIN DE SAISON Avant de retirer l’appareil du service pour l’année, faites fonctionner l’appareil sur le mode ventilateur élevé pendant une demi-journée pour vous assurer que l’intérieur de l’appareil est sec. Cela aidera à éviter la croissance de la moisissure ou de la moisissure à l’intérieur de l’appareil. Assurez-vous que le filtre est propre et sec. Rangez l’appareil dans un endroit sec. Remarque: Lors de l’installation ou de l’enlèvement de l’appareil de la fenêtre, veillez à ce qu’il soit prudent de l’empêcher de tomber vers l’arrière. Il est recommandé que l’installation ou l’enlèvement soit complété avec une assistance pour éviter les blessures aux personnes ou les dommages matériels ou l’appareil. DISPOSITION Vérifiez la conformité réglementaire locale concernant l’élimination approuvée et sûre de cet appareil. AS - Erreur du capteur de température ambiante HI - Erreur du capteur de température LO - Erreur du capteur de température . - Erreur du capteur de température de l’évaporateur 30 DÉPANNAGE Danby soins du consommateur : 1-800-263-2629 ou [email protected] Heures d’ouverture : Du lundi au jeudi, de 8 h 30 à 18 h, heure de l’Est Vendredi, de 8 h 30 à 16 h, heure de l’Est Les informations contenues dans ce manuel sont sujettes à modification sans préavis. PROBLÈME L’appareil ne fonctionnera pas Refroidissement insuffisant Bruit Les odeurs CAUSE POSSIBLE • • • • • • • • L’eau s’écoule à l’intérieur • Eau dégouttant à l’extérieur • Accumulation de givre • • La fiche n’est pas complètement insérée dans la prise murale Fusible soufflé ou disjoncteur Le filtre à air est sale Flux d’air bloqué La taille de l’appareil est trop petite pour l’application Support inadéquat dans l’installation de fenêtre Formation de moisissure sur des surfaces intérieures humides Placer un comprimé d’algaïcide dans un moule de base; poussez la tablette à travers la grille de chaque côté de l’appareil L’appareil n’est pas correctement incliné pour permettre à l’eau de s’écouler vers l’extérieur Sur des jours très chauds ou humides, l’eau qui goutte à l’arrière de l’appareil est normale Lorsque les températures extérieures sont inférieures à 18,3°C (65°F), une gelée peut se former lorsque l’appareil est en mode refroidissement Mettez l’appareil en mode ventilateur seulement jusqu’à ce que le givre fond Cet appareil numérique de classe B est conforme à la norme Canadienne ICES-003. CAN ICES-3 (B) Cet équipement a été testé et s’est avéré conforme aux limites d’un appareil numérique de classe B, conformément à la partie 15 des règles de la FCC. Ces limites sont conçues pour fournir une protection raisonnable contre les interférences dans une installation résidentielle. Cet équipement génère, utilise et peut émettre de l’énergie radiofréquence et, s’il n’est pas installé et utilisé conformément aux instructions, peut provoquer des interférences dans les communications radio. Cependant, il n’y a aucune garantie que des interférences ne se produiront pas dans une installation particulière. Si cet équipement cause des interférences à la réception de la radio ou de la télévision, ce qui peut être déterminé en allumant et éteindre l’équipement, l’utilisateur est encouragé à essayer de corriger les interférences en prenant une ou plusieurs des mesures suivantes: 1. Réorientez ou déménagez l’antenne de réception. 2. Augmenter la séparation entre l’équipement et le récepteur. 3. Connectez l’équipement à une prise de courant sur un circuit différent de celui auquel le récepteur est connecté. 4. Consultez le revendeur ou un technicien expérimenté en radio / télévision pour obtenir de l’aide. Les modifications ou modifications non approuvées par la partie responsable de la conformité de la FCC peuvent annuler l’autorisation de l’utilisateur d’utiliser l’équipement. Cet appareil est conforme à la partie 15 des règles de la FCC. L’opération est soumise aux deux conditions suivantes: 1. Cet appareil ne doit pas provoquer d’interférence. 2. Cet appareil doit accepter toute interférence reçue, y compris les interférences pouvant 31 entraîner un fonctionnement indésirable. LIMITED IN-HOME APPLIANCE WARRANTY GARANTIE LIMITÉE « EN ATELIER » Thisappareil quality product is warranted be free from manufacturer’s defectsdein matière material and workmanship, that the unit is utilisé useddans underles theconditions normal operating Cet de qualité est to garanti exempt de tout vice première et deprovided fabrication, s’il est normales conditions intended by the manufacturer. recommandées par le fabricant. This warranty is available only to the person to whom initial the unitde wasl’appareil originally soldvendu by Danby (Canada) or Danby Inc. (U.S.A.) (hereafter Cette garantie n’est offerte qu’à l’acheteur parProducts DanbyLimited Products Limited (Canada)Products ou Danby Products Inc. “Danby”) or by an«authorized distributor Danby, andses is non-transferable. (É.-U.) (ci-après Danby ») ou parof l’un des distributeurs agréés et elle ne peut être transférée. CONDITIONS WARRANTY à partir de la date de l’achat, sans aucune prolongation Les pièces en plastique sont garanties pendant trente (30)TERMS joursOFseulement Plastic parts, are warranted for thirty (30) days only from purchase date, with no extensions provided. prévue. Premiers First Year 24 mois Pour obtenir un To obtain service Pendant premiers vingtany quatre (24) mois, pièces de ce or produit During the firstles twelve (12) months, functional parts of thistoutes productlesfound to be fonctionnelles defective, will be repaired replaced,qui s’avèrent at warrantor’s défectueuses réparées ou remplacées, selon le choix du garant, sans frais à l’acheteur initial. option, at no chargeseront to the ORIGINAL purchaser. Contactez le revendeur où l'appareil a été acheté ou contactez le dépôt de service Danby autorisé le plus Danby reserves the right to limit the boundaries of “In Home Service” to the proximity of an Authorized Service Depot. Any app liance proche, où le service doit être effectué par un technicien de service qualifié. Si le service est effectué sur Service requiring service outside the limited boundaries of “In Home Service” , i t will be the consumer’s responsibility to transport the appliance (at l'appareil par une personne autre qu'un dépôt de service autorisé, toutes les obligations de Danby en vertu de their own expense) to the original retailer (point of purchase) or a service depot for repair. See “Boundaries of In Home Serv ice” below. cette garantie seront annulées. Contact your dealer from whom your unit was purchased, or contact your nearest authorized Danby service depot, where service must be performed by a qualified service technician. Il est de la responsabilité de l'acheteur de transporter l'appareil vers le dépôt de service agréé le plus proche. If service is performed on the units by anyone other than an authorized service depot, or the unit is used for commercial appli cation, all obligations of Danby under this warranty shall be void. Les frais de transport entre votre domicile et le lieu de l'entretien ne sont pas couverts par la présente garantie et doivent être acquittés par l'acheteur. Boundaries of If the appliance is installed in a location that is 100 kilometers (62 miles) or more from the nearest service center your unit must be In Homepartie Service de la garantie delivered tonetheprévoit nearest implicitement authorized Danbyque Service as service onlyresponsable be performed bydes a technician qualified and certif ied for ou Aucune le Depot, fabricant seramust tenu dommages subis par les aliments warranty service by Danby. Transportation charges to and de froml’appareil the service location not protected by this warranty and are t he d’autres types de contenu, qu’ils soient causés par la défectuosité ou parareson usage adéquat ou inadéquat. responsibility of the purchaser. EXCLUSIONS EnNothing vertu within de lathis présente, il n’existe aucune autre garantie,orcondition représentation, soit cexprimée de façon warranty shall imply that Danby will be responsible liable for anyouspoilage or damage to qu’elle food or other ontentsouoftacite, this appliance, whether due manifeste ouofintentionnelle, par ses ordistributeurs to any defect the appliance, or its use,Danby whetherou proper improper. agréés. De même, sont exclues toutes les autres garanties, conditions ou représentations, y compris les garanties, conditions ou représentations en vertu de toute loi régissant la vente de produits ou de toute autre législation ou règlement semblable. En vertu de la présente, Danby ne peut être tenue responsable en cas de blessures EXCLUSIONS corporelles ou de dégâts matériels, y compris à l’appareil, quelle qu’enor soit les causes. tenuebyresponsable Save as herein provided, Danby, there are no other warranties, conditions, representations guarantees, express orDanby implied,ne m peut pas ade être or intended Danby or its des dommages indirects fonctionnement défectueux or deguarantees, l’appareil. En achetant l’appareil, accepte ordeguarantees tenir sans authorized distributors and all dus otherau warranties, conditions, representations including any warranties, conditio l’acheteur ns, representations reproche de toute responsabilité en cas de réclamation pour toute blessure ou tout dégât under any et Saledeof dégager Goods Act orDanby like legislation or statue is hereby expressly excluded. Save as herein provided, Danby shall no corporelle t be responsible for any matériel damages causé par orcet appareil. to persons property, including the unit itself, howsoever caused or any consequential damages arising from the malfunction o f the unit and by the purchase of CONDITIONS GÉNÉRALES the unit, the purchaser does hereby agree to indemnify and hold harmless Danby from any claim for damages to persons or propert y caused by the unit. La garantie ou assurance ci-dessus ne s’applique pas si les dégâts ou réparations sont dus aux cas suivants : 1) Panne de courant. GENERAL PROVISIONS 2) Dommages subis pendant le transport ou le déplacement de l’appareil. warranty or insurance hereinincorrecte contained or(tension set out shall apply when damage or repair is caused by anyincorrects). of the following: 3)NoAlimentation électrique faible, câblage défectueux, fusibles 4) Accident, modification, emploi abusif ou incorrect de l’appareil tel qu'une circulation d'air inadéquate dans la pièce ou des 1) Power failure. conditions de fonctionnement (température extrêmement élevée ou basse). 2) Damage in transit or whenanormales moving the appliance. 5) Utilisation dans un but commercial ou industriel (à savoir, si l'appareil n'est pas installé dans un domicile résidentiel). 3) Improper power supply such as low voltage, defective house wiring or inadequate fuses. 6) Incendie, dommages causés par l’eau, le vol, la guerre, une émeute, des hostilités, ou en cas de force majeure (ouragan, 4) Accident, ditions inondation, etc.). alteration, abuse or misuse of the appliance such as inadequate air circulation in the room or abnormal operating con (extremely high or low room temperature). 7) Visites d’un technicien pour expliquer le fonctionnement de l’appareil au propriétaire. 5) Use for commercial or industrial purposes encastrement (ie. If the applianced'un is notappareil installed inautoportant, a domestic residence). 8) Installation inappropriée (par exemple, ou utilisation extérieure d'un appareil non conçu à cet effet, compris, mais theft, sanswar, s'y riot, limiter : lesacts garages, lesaspatios, porches 6) yFire, water damage, hostility, of God such hurricanes,lesfloods etc. ou ailleurs, qui ne sont pas correctement isolés ou climatisés). 7) Service calls resulting in customer education. 8) Improper Installation (ie. Building-in of a free standing appliance or using an appliance outdoors that is not approved for out door application). La preuve de la date d'achat sera requise pour les réclamations de garantie; conserver la facture de vente. Dans le cas où un service Proof of purchase date will be required for warranty claims; so, please retain bills of sale. In the event warranty service is required, present this document to our de garantie est requis, présentez la preuve d'achat à notre dépôt de service agréé. AUTHORIZED SERVICE DEPOT. Warranty Service Service sous garantie In-home En Atelier Danby Products Limited Danby Products Limited PO 1778, Guelph, Ontario, N1H 6Z9 POBox Box 1778, Guelph, Ontario, Canada N1H Canada 6Z9 Téléphone : (519) 837-0920 Télécopieur : (519) 837-0449 Telephone: (519) 837-0920 FAX: (519) 837-0449 1-800-263-2629 1-800-263-2629 02/18 04/09 Danby Products Danby Products Inc. Inc. PO Box PO 669, Findlay, U.S.A. Box 669, Findlay,Ohio, Ohio, U.S.A. 45840 45840 Téléphone : (419) 425-8627 (419) 425-8629 Telephone: (419)Télécopieur 425-8627 FAX:: (419) 425-8629 Bienvenido Bienvenido a la familia Danby. Estamos orgullosos de nuestros productos de calidad y creemos en un servicio confiable. Sugerimos que lea este manual del propietario antes de conectar el nuevo aparato ya que contiene información importante sobre la operación, información de seguridad, solución de problemas y consejos de mantenimiento para garantizar la fiabilidad y longevidad de su electrodoméstico. Visite www.Danby.com para acceder a herramientas de autoservicio, preguntas frecuentes y mucho más. Para asistencia adicional, llame al 1-800-263-2629. Tenga en cuenta la información siguiente; Necesitará esta información para obtener un servicio bajo garantía. Debe proporcionar el recibo de compra original para validar su garantía y recibir servicio. Número de modelo: _____________________________________________ Número de serie: _______________________________________________ Fecha de compra: _______________________________________________ Necesitas ayuda? Antes de llamar al servicio, aquí hay algunas cosas que puede hacer para ayudarnos a servirle mejor. Lea este manual del propietario: Contiene instrucciones para ayudarle a usar y mantener su aparato correctamente. Si recibe un aparato dañado: Inmediatamente póngase en contacto con el minorista o el constructor que le vendió el aparato. Ahorre tiempo y dinero: Consulte la sección de solución de problemas al final de este manual antes de llamar. Esta sección le ayudará a resolver problemas comunes que pueden ocurrir. 1-800-26- Danby (1-800-263-2629) 33 Importantes Instrucciones de Seguridad LEA Y SIGA TODAS LAS INSTRUCCIONES DE SEGURIDAD REQUERIMIENTOS DE SEGURIDAD INSTRUCCIONES DE CONEXION A TIERRA PELIGRO: Riesgo de incendio o explosión. Refrigerante inflamable utilizado. No dañe el circuito de refrigerante. Este aparato debe estar conectado a tierra. La puesta a tierra reduce el riesgo de descarga eléctrica proporcionando un cable de escape para la corriente eléctrica. • Asegúrese de que el servicio sea realizado por personal de servicio autorizado de fábrica, para minimizar los daños del producto o los problemas de seguridad. • Consulte el manual de reparación o la guía del propietario antes de intentar reparar este producto. Deben seguirse todas las precauciones de seguridad. • Deséchese adecuadamente de acuerdo con las regulaciones federales o locales. • Siga cuidadosamente las instrucciones de manejo. • Mantenga las aberturas de ventilación, en el aparato, sin obstrucciones. • No utilice dispositivos mecánicos u otros medios para acelerar el proceso de descongelación. • Los niños deben ser supervisados para asegurarse de que no jueguen con el aparato. • No almacene ni instale el aparato cerca de fuentes de ignición que funcionen continuamente, como llamas o una estufa de gas. • No operar cerca del agua o en una habitación húmeda. • No perforar o quemar. • Tenga en cuenta que los refrigerantes no pueden contener un olor. • El aparato debe almacenarse para evitar daños mecánicos. Todo el cableado debe cumplir con los códigos locales y nacionales y debe ser instalado por un electricista calificado. Verifique la fuente de alimentación disponible y resuelva cualquier problema de cableado antes de instalar y operar este dispositivo. Este aparato tiene un cable que tiene un cable de conexión a tierra con un enchufe de 3 clavijas. El cable de alimentación debe estar enchufado en un tomacorriente que esté debidamente conectado a tierra. Si el tomacorriente es un enchufe de pared de 2 terminales, debe ser reemplazado por un tomacorriente de pared de 3 clavijas debidamente conectado a tierra. La placa de características en serie indica el voltaje y la frecuencia que el aparato está diseñado para. ADVERTENCIA - El uso incorrecto del enchufe de conexión a tierra puede resultar en un riesgo de descarga eléctrica. Consulte a un electricista calificado o agente de servicio si las instrucciones de conexión a tierra no se entienden completamente o si existe duda sobre si el aparato está debidamente conectado a tierra. No conecte el aparato a los cables de extensión ni con otro aparato en la misma toma de corriente. No empalme el cable de alimentación. No corte ni extraiga en ningún caso la tercera clavija de tierra del cable de alimentación. No utilice cables de extensión ni adaptadores sin conexión a tierra (dos clavijas). Si el cable de alimentación está dañado, debe ser reemplazado por el fabricante, su agente de servicio o persona calificada similar para evitar riesgos. La placa de características ubicada en el lado derecho del aparato, justo encima del cable de alimentación, contiene datos eléctricos y otros datos técnicos. Este dispositivo no está destinado a ser utilizado por personas (incluidos niños) cuyas capacidades físicas, sensoriales o mentales pueden ser diferentes o reducidas, o que carecen de experiencia o conocimiento, a menos que dichas personas sean supervisadas o entrenadas para operar el dispositivo por una persona responsable de su la seguridad. PRECAUCIÓN: RIESGO DE INCENDIO Refrigerante inflamable utilizado. Al mantener o desechar el acondicionador de aire, no se debe permitir que el refrigerante se ventile al aire libre. ¡GUARDE ESTAS INSTRUCCIONES! 34 Importantes Instrucciones de Seguridad LEA Y SIGA TODAS LAS INSTRUCCIONES DE SEGURIDAD Cualquier persona involucrada en trabajar en el circuito de refrigerante debe tener un certificado válido y vigente de una autoridad de evaluación acreditada de la industria que autorice su competencia para manejar refrigerantes de manera segura de acuerdo con una especificación de evaluación reconocida por la industria. La reparación solo se realizará según lo recomendado por el fabricante. El mantenimiento y las reparaciones que requieran la asistencia de otro personal calificado deben realizarse bajo la supervisión de la persona competente en el uso de refrigerantes inflamables. Al mantener o desechar el aparato, el refrigerante debe recuperarse adecuadamente y no debe permitirse que se descargue al aire directamente. Información sobre mantenimiento 1. Cheques a la zona: Antes de comenzar a trabajar en sistemas que contengan refrigerantes inflamables, se necesitan controles de seguridad para garantizar que se minimice el riesgo de ignición. Para la reparación del sistema de refrigeración, se deben cumplir las siguientes precauciones antes de realizar trabajos en el sistema. 2. Procedimiento de trabajo: El trabajo debe realizarse bajo un procedimiento controlado para minimizar el riesgo de que haya un gas o vapor inflamable mientras se realiza el trabajo. 3. Área de trabajo general: Todo el personal de mantenimiento y otras personas que trabajan en el área local deben recibir instrucciones sobre la naturaleza del trabajo que se está llevando a cabo. Se evitará el trabajo en espacios confinados. El área alrededor del espacio de trabajo debe ser seccionado. Asegúrese de que las condiciones dentro del área de trabajo se hayan hecho seguras eliminando todo el material inflamable. 5. Presencia de extintor de incendios: Si se debe realizar algún trabajo en caliente en el equipo de refrigeración o en cualquier pieza asociada, debe estar disponible el equipo de extinción de incendios adecuado. Tenga un extintor de polvo seco o C02 adyacente al área de trabajo. 6. No hay fuentes de ignición: Ninguna persona que realice trabajos en relación con un sistema de refrigeración que implique exponer cualquier tubería que contenga o haya contenido refrigerante inflamable deberá utilizar ninguna fuente de ignición de tal manera que pueda provocar riesgo de incendio o explosión. Todas las fuentes de ignición posibles, incluido el consumo de cigarrillos, deben mantenerse lo suficientemente lejos del lugar de instalación, reparación, eliminación y eliminación durante los cuales es posible que se libere refrigerante inflamable al espacio circundante. Antes de realizar el trabajo, se debe inspeccionar el área alrededor del equipo para asegurarse de que no haya peligros inflamables o riesgos de ignición. No se mostrarán señales de fumar. 7. Zona ventilada: Asegúrese de que el área esté al aire libre o de que esté adecuadamente ventilada antes de entrar en el sistema o realizar cualquier trabajo en caliente. Un cierto grado de ventilación deberá continuar durante el período de trabajo. La ventilación debe dispersar de forma segura cualquier refrigerante liberado y, preferiblemente, expulsarlo externamente a la atmósfera. 8. Comprobaciones al equipo de refrigeración: Donde se cambien los componentes eléctricos, deben ser adecuados para el propósito y para la especificación correcta. En todo momento se seguirán las pautas de mantenimiento y servicio del fabricante. En caso de duda, consulte al departamento técnico del fabricante para obtener ayuda. 4. Comprobando la presencia de refrigerante: Se deben verificar con un detector de refrigerante adecuado antes y durante el trabajo para garantizar que el técnico tenga conocimiento de las atmósferas potencialmente inflamables. Asegúrese de que el equipo de detección de fugas que se está utilizando sea adecuado para el uso con refrigerantes inflamables, es decir, que no produzcan chispas, que estén adecuadamente sellados y sean intrínsecamente seguros. 35 Importantes Instrucciones de Seguridad LEA Y SIGA TODAS LAS INSTRUCCIONES DE SEGURIDAD Se aplicarán los siguientes controles a las instalaciones que utilizan refrigerantes inflamables: Reparaciones a componentes sellados. 1. Durante las reparaciones de componentes sellados, todos los suministros eléctricos se deben desconectar del equipo en el que se está trabajando antes de retirar las cubiertas selladas, etc. Si es absolutamente necesario contar con un suministro eléctrico al equipo durante el servicio, se debe realizar una detección permanente de fugas. se ubicará en el punto más crítico para advertir de una situación potencialmente peligrosa. • El tamaño de carga está de acuerdo con el tamaño de la habitación dentro de la cual se instalan las piezas que contienen refrigerante. • La maquinaria de ventilación y las salidas funcionan adecuadamente y no están obstruidas. • Si se está utilizando un circuito de refrigeración indirecto, se debe revisar el circuito secundario para detectar la presencia de refrigerante. • El marcado al equipo sigue siendo visible y legible. Las marcas y signos que se vuelven ilegibles deben ser corregidos. • La tubería o los componentes de refrigeración se instalan en una posición en la que es poco probable que estén expuestos a alguna sustancia que pueda corroer los componentes que contienen refrigerante, a menos que los componentes estén construidos con materiales que sean inherentemente resistentes a la corrosión o que estén protegidos adecuadamente contra la corrosión. 2. Para garantizar que al trabajar con componentes eléctricos, la carcasa no se altera de tal manera que el nivel de protección se vea afectado, se debe prestar especial atención a lo siguiente: 9. Cheques a dispositivos eléctricos: La reparación y el mantenimiento de los componentes eléctricos deben incluir controles de seguridad iniciales y procedimientos de inspección de componentes. Si existe una falla que pueda comprometer la seguridad, no se debe conectar ningún suministro eléctrico al circuito hasta que se resuelva satisfactoriamente. Si la falla no se puede corregir de inmediato, pero es necesario continuar la operación, se debe utilizar una solución temporal adecuada. Esto se informará al propietario del equipo para que se informe a todas las partes. Los controles iniciales de seguridad incluirán: • Que los condensadores están descargados. Esto debe hacerse de manera segura para evitar la posibilidad de chispas. • Que no se exponen componentes eléctricos ni cableado mientras se está cargando, recuperando o purgando el sistema. • Que hay continuidad de la unión de la tierra. • Daños a los cables, número excesivo de conexiones, terminales no fabricados según las especificaciones originales, daños a los sellos, ajuste incorrecto de los casquillos, etc. • Asegúrese de que el aparato esté montado de forma segura. • Asegúrese de que los sellos o materiales de sellado no se hayan degradado de manera que ya no sirvan para evitar la entrada de atmósferas inflamables. Las piezas de repuesto deben estar de acuerdo con las especificaciones del fabricante. Nota: el uso de sellador de silicona puede inhibir la efectividad de algunos tipos de equipos de detección de fugas. Los componentes intrínsecamente seguros no tienen que estar aislados antes de trabajar en ellos. Reparación a componentes intrínsecamente seguros. No aplique ninguna carga inductiva o capacitiva permanente al circuito sin asegurarse de que esto no exceda el voltaje y la corriente permitidos para el equipo en uso. Los componentes intrínsecamente seguros son los únicos tipos en los que se puede trabajar mientras se vive en presencia de una atmósfera inflamable. El aparato de prueba debe estar en la clasificación correcta. Reemplace los componentes solo con partes especificadas por el fabricante. Otras partes pueden provocar la ignición de refrigerante en la atmósfera debido a una fuga. 36 Importantes Instrucciones de Seguridad LEA Y SIGA TODAS LAS INSTRUCCIONES DE SEGURIDAD Cableado Traslado y evacuación Compruebe que el cableado no esté sujeto a desgaste, corrosión, presión excesiva, vibración, bordes afilados o cualquier otro efecto ambiental adverso. La verificación también debe tener en cuenta los efectos del envejecimiento o la vibración continua de fuentes como compresores o ventiladores. Al entrar en el circuito de refrigerante para realizar reparaciones o para cualquier otro propósito, se deben utilizar procedimientos convencionales. Sin embargo, es importante que se sigan las mejores prácticas ya que la inflamabilidad es una consideración. Se seguirán los siguientes procedimientos: • • • • • Detección de refrigerantes inflamables. Bajo ninguna circunstancia deben utilizarse fuentes potenciales de ignición en la búsqueda o detección de fugas de refrigerante. No se debe usar una antorcha de halogenuros o cualquier otro detector que use una llama desnuda. Métodos de detección de fugas Los siguientes métodos de detección de fugas se consideran aceptables para sistemas que contienen refrigerantes inflamables: • Se deben usar detectores electrónicos de fugas para detectar refrigerantes inflamables, pero la sensibilidad puede no ser adecuada o puede necesitar una recalibración. El equipo de detección debe estar calibrado en un área libre de refrigerante. Asegúrese de que el detector no sea una fuente potencial de ignición y que sea adecuado para el refrigerante utilizado. • El equipo de detección de fugas se fijará en un porcentaje del LFL del refrigerante y se calibrará para el refrigerante empleado y se confirmará el porcentaje apropiado de gas (25% máximo). • Los fluidos de detección de fugas son adecuados para el uso con la mayoría de los refrigerantes, pero se debe evitar el uso de detergentes que contengan cloro, ya que el cloro puede reaccionar con el refrigerante y corroer el cobre o las tuberías. • Si se sospecha una fuga, todas las llamas descubiertas deben retirarse o extinguirse. • Si se encuentra una fuga de refrigerante que requiere soldadura fuerte, todo el refrigerante se recuperará del sistema o se aislará mediante válvulas de cierre en una parte del sistema alejada de la fuga. El nitrógeno libre de oxígeno (OFN) se purgará a través del sistema antes y durante el proceso de soldadura fuerte. Retire el refrigerante. Purgar el circuito con gas inerte. Evacuar. Purgar de nuevo con gas inerte. Abrir el circuito mediante corte o soldadura fuerte. • La carga de refrigerante se recuperará en los cilindros de recuperación correctos. El sistema se debe lavar con OFN para que la unidad sea segura. Este proceso puede necesitar repetirse varias veces. No se debe utilizar aire comprimido ni oxígeno para esta tarea. • El lavado se logrará rompiendo el vacío en el sistema con OFN y continuando con el llenado hasta que se alcance la presión de trabajo, luego ventilando a la atmósfera y finalmente bajando al vacío. Este proceso debe repetirse hasta que no haya refrigerante dentro del sistema. Cuando se utiliza la carga OFN final, el sistema debe descargarse a presión atmosférica para permitir que se realice el trabajo. Esta operación es absolutamente vital si se realizan operaciones de soldadura fuerte en la tubería. • Asegúrese de que la salida de la bomba de vacío no esté cerca de ninguna fuente de ignición y que haya ventilación disponible. Procedimientos de carga Además de los procedimientos de carga convencionales, se deben seguir los siguientes requisitos: • Asegúrese de que no se contamine con refrigerantes diferentes cuando utilice equipos de carga. Las mangueras o líneas deben ser lo más cortas posible para minimizar la cantidad de refrigerante que contienen. • Los cilindros se mantendrán en posición vertical. • Asegúrese de que el sistema de refrigeración esté conectado a tierra antes de cargar el sistema con refrigerante. • Etiquete el sistema cuando se complete la carga, si no está ya etiquetado. • Se debe tener mucho cuidado de no sobrecargar el sistema de refrigeración. • Antes de recargar el sistema, se someterá a prueba de presión con OFN. El sistema debe ser probado contra fugas al finalizar la carga pero antes de la puesta en servicio. Se realizará una prueba de fugas de seguimiento antes de abandonar el sitio. 37 Importantes Instrucciones de Seguridad LEA Y SIGA TODAS LAS INSTRUCCIONES DE SEGURIDAD Desmantelamiento Recuperación Antes de llevar a cabo este procedimiento, es esencial que el técnico esté completamente familiarizado con el equipo en todo su detalle. Se recomienda una buena práctica que todos los refrigerantes se recuperen de manera segura. Antes de realizar la tarea, se debe tomar una muestra de aceite y refrigerante en caso de que se requiera un análisis antes de reutilizar el refrigerante recuperado. Es esencial que la energía eléctrica esté disponible antes de comenzar la tarea. Cuando se retira refrigerante de un sistema, ya sea para servicio o cierre, se recomienda que todos los refrigerantes se eliminen de manera segura. A. Familiarizarse con el equipo y su funcionamiento. B. Sistema de aislamiento eléctrico. C. Antes de intentar el procedimiento, asegúrese de que: • El equipo de manejo mecánico está disponible si es necesario para el manejo de cilindros de refrigerante. • Todo el equipo de protección personal está disponible y se está utilizando correctamente. • El proceso de recuperación es supervisado en todo momento por una persona competente. • Los equipos y cilindros de recuperación cumplen con las normas apropiadas. D. Bombear el sistema de refrigerante, si es posible. E. Si no es posible un vacío, haga un colector para que se pueda eliminar el refrigerante de varias partes del sistema. F. Asegúrese de que el cilindro esté situado en la balanza antes de que tenga lugar la recuperación. G. Arranque la máquina de recuperación y opere de acuerdo con las instrucciones del fabricante. H. No llene en exceso los cilindros. No más del 80% de volumen de carga líquida. I. No exceda la presión máxima de trabajo del cilindro, ni siquiera temporalmente. J. Cuando los cilindros se hayan llenado correctamente y se haya completado el proceso, asegúrese de que los cilindros y el equipo se retiren del sitio rápidamente y que todas las válvulas de aislamiento del equipo estén cerradas. K. El refrigerante recuperado no debe cargarse en otro sistema de refrigeración a menos que se haya limpiado y revisado. Etiquetado El equipo debe estar etiquetado indicando que ha sido retirado del servicio y vaciado de refrigerante. La etiqueta deberá estar fechada y firmada. Asegúrese de que haya etiquetas en el equipo que indiquen que el equipo contiene refrigerante inflamable. Cuando transfiera refrigerante a los cilindros, asegúrese de que solo se utilicen los cilindros apropiados para recuperar el refrigerante. Asegúrese de que esté disponible el número correcto de cilindros para mantener la carga total del sistema. Todos los cilindros que se utilizarán están diseñados para el refrigerante recuperado y etiquetados para ese refrigerante, es decir, cilindros especiales para la recuperación de refrigerante. Los cilindros deben estar completos con válvula de alivio de presión y válvulas de cierre asociadas en buen estado de funcionamiento. Los cilindros de recuperación vacíos se evacuan y, si es posible, se enfrían antes de que se produzca la recuperación. El equipo de recuperación debe estar en buen estado de funcionamiento con un conjunto de instrucciones sobre el equipo que se encuentra a mano y debe ser adecuado para la recuperación de refrigerantes inflamables. Además, un conjunto de balanzas calibradas estará disponible y en buen estado de funcionamiento. Las mangueras deben estar completas con acoplamientos de desconexión sin fugas y en buenas condiciones. Antes de usar la máquina de recuperación, verifique que esté en buen estado de funcionamiento, que se haya mantenido correctamente y que todos los componentes eléctricos asociados estén sellados para evitar la ignición en caso de una fuga de refrigerante. Consulte al fabricante en caso de duda. El refrigerante recuperado se devolverá al proveedor de refrigerante en el cilindro de recuperación correcto y se dispondrá la nota de transferencia de residuos correspondiente. No mezcle refrigerantes en unidades de recuperación y especialmente en cilindros. Si se deben retirar los compresores o los aceites de compresores, asegúrese de que hayan sido evacuados a un nivel aceptable para asegurarse de que no quede refrigerante inflamable dentro del lubricante. El proceso de evacuación se llevará a cabo antes de devolver el compresor a los proveedores. Para acelerar este proceso solo debe emplearse calentamiento eléctrico del cuerpo del compresor. Cuando el aceite se drena de un sistema, debe llevarse a cabo de manera segura. 38 INSTRUCCIONES DE INSTALACIÓN UBICACIÓN HERRAMIENTAS REQUERIDAS Este aire acondicionado está diseñado para ventanas de una o dos ventanas. Dado que los diseños de las ventanas varían, puede ser necesario hacer algunas modificaciones para una instalación segura. • Destornilladores: Phillips y cabeza plana. • Taladro eléctrico: 3.2 mm (1/8 pulgada) de diámetro de la broca • Lápiz • Cinta métrica • Tijeras • Nivel de carpintero Este acondicionador de aire no está diseñado para ventanas verticales de tipo deslizante o para instalación “a través de la pared”. Asegúrese de que la ventana y el marco estén estructuralmente firmes y libres de madera seca o podrida. Instale el aire acondicionado en una ventana en un costado del edificio que favorezca más sombra que la luz solar. Si el electrodoméstico debe estar expuesto a la luz solar directa, se recomienda proporcionar un toldo de sombra sobre el electrodoméstico para garantizar un funcionamiento eficiente. No instale el aparato donde se sospeche una fuga de gas combustible. Este aparato está diseñado para evaporar la condensación en condiciones normales. En condiciones extremadamente cálidas o húmedas, el exceso de condensación puede desbordarse hacia el exterior. El aparato debe instalarse donde la condensación no pueda gotear sobre peatones o propiedades vecinas. ACCESORIOS Los siguientes accesorios se incluyen con el aparato y se deben utilizar durante la instalación. 1. Tornillos de 13 mm (1/2”) (x7) 2. Tornillos de 9,5 mm (3/8”) (X4) (instalados de fábrica en algunos modelos). 3. Cerradura de seguridad 4. Sello de espuma adhesiva 5. Sello de espuma regular 6. Soporte de montaje en forma de “L” (instalado de fábrica en algunos modelos). 7. Soporte para ventanas de madera (x2) 8. Soporte para ventanas de vinilo (x2) 9. Burlete (x5) 10. Cortinas laterales (x2) 2 1 4 Deje suficiente espacio alrededor del aparato para permitir una amplia circulación de aire. La parte posterior del aparato debe estar al aire libre, no debe estar en un garaje u otra habitación. Mantenga el aparato alejado de obstáculos y al menos a 76 cm (30”) del suelo. Asegúrese de que las cortinas y otras obstrucciones no bloqueen el flujo de aire al aparato. 30.5 pulg (12 cm) 5 6 7 8 9 10 50.8 cm (20 pulgadas) 76.2 cm (30 pulgadas) 50.8 cm (20 pulgadas) 39 3 INSTRUCCIONES DE INSTALACIÓN INSTALACIÓN Compruebe el ángulo de inclinación Fije las cortinas laterales al aparato deslizando el marco de la cortina en el canal lateral del gabinete. Las cortinas están etiquetadas como “izquierda” y “derecha” en los marcos. Esto se refiere a los lados izquierdo y derecho del aparato cuando se mira hacia la parte frontal del aparato. El acondicionador de aire debe inclinarse hacia abajo hacia el exterior aproximadamente de 3° a 4°. Esta inclinación estimulará el drenaje del agua condensada hacia el exterior. Si hay fugas de agua condensada en el interior de la casa, compruebe el ángulo de inclinación y ajuste si es necesario. Corte el sello de espuma regular para que se ajuste al área del alféizar de la ventana sobre la que descansará el aire acondicionado. Mida el ángulo de inclinación desde el frente del borde del gabinete. La diferencia de altura entre la parte delantera y la parte posterior del aparato, denominada “A” en la imagen inferior, debe ser de aproximadamente 19 mm a 2.5 cm (3/4 de pulgada - 1 pulgada). Coloque el aire acondicionado en la ventana con el soporte de montaje en forma de “L” colocado frente a la hoja superior. La parte inferior del gabinete debe colocarse en la parte empotrada del marco de la ventana. Tire de la hoja superior de la ventana hacia abajo hasta que descanse justo detrás de la brida delantera del soporte de montaje en forma de “L”. A Expanda las cortinas laterales en cada lado y asegure la parte superior de los marcos al marco de la ventana con un tornillo de 13 mm (1/2 “) en cada lado del soporte de montaje en forma de” L “. Fije las abrazaderas en la parte inferior de cada cortina al alféizar de la ventana con un tornillo de 13 mm (1/2 ”) a cada lado del gabinete. Coloque el sello de espuma adhesiva en la abertura entre las ventanas interior y exterior y fije la cerradura de seguridad al marco de la ventana exterior con dos tornillos de 13 mm (1/2 ”). SOPORTE L El soporte en forma de “L” puede venir instalado de fábrica en algunos modelos. Si el soporte en forma de “L” no está preinstalado, fíjelo a la parte superior del gabinete como se muestra a continuación utilizando los tornillos de 9.5 mm (3/8“) provistos (x4). 40 INSTRUCCIONES DE OPERACIÓN PANEL DE CONTROL 1. Receptor de control remoto: Asegúrese de que este receptor no esté oscurecido por cortinas u otros elementos, ya que podría afectar el funcionamiento del control remoto. 2. Indicador luminoso Sígueme: Se ilumina cuando la función Sígueme está activa. Sólo se puede ajustar desde el mando a distancia. 3. Botón de encendido: Se utiliza para encender o apagar el aparato. 4. Botón de modo: Se utiliza para elegir el modo de funcionamiento. 5. Flechas arriba y abajo: Se utiliza para ajustar la temperatura ajustada en incrementos de 1 ° y la función del temporizador en incrementos de 30 minutos hasta 10 horas y luego en incrementos de 1 hora hasta 24 horas. 6. Panel de visualización: Muestra la temperatura ajustada, la temperatura ambiente y los ajustes del temporizador. Para cambiar la escala de temperatura que se está visualizando, presione los botones arriba y abajo al mismo tiempo. 7. Botón del ventilador: Se utiliza para ajustar la velocidad del ventilador. El ventilador puede ajustarse a Bajo, Medio, Alto y Auto. 8. Botón de conexión inalámbrica: se utiliza para conectarse a una red inalámbrica. 9. Botón de ahorro de energía: Se utiliza para configurar la función de ahorro de energía. 10. Botón filtro: La luz indicadora se iluminará como un recordatorio para comprobar el filtro. Una vez limpiado el filtro, utilice este botón para reanudar el funcionamiento. 11. Botón dormir: Se utiliza para configurar la función dormir. 12. Botón del temporizador: Se utiliza para establecer el temporizador de encendido automático y apagado automático. 2 1 6 3 4 5 8 9 10 7 11 41 12 INSTRUCCIONES DE OPERACIÓN CONTROL REMOTO 1. Panel de visualización: Muestra la temperatura establecida, la temperatura ambiente y la configuración del temporizador. Para cambiar la escala de temperatura que se muestra, presione el botón °C/°F. 1 2. Flechas arriba y abajo: Se utiliza para ajustar la temperatura ajustada en incrementos de 1 ° y la función del temporizador en incrementos de 30 minutos hasta 10 horas y luego en incrementos de 1 hora hasta 24 horas. 3. Botón de modo: Se utiliza para elegir el modo de funcionamiento. TEMP 4. Botón Sígueme: Se utiliza para configurar la función sígueme. 2 5. Botón °C/°F: Use para cambiar la escala de temperatura. 6. Botón LED: Presione para encender o apagar la luz trasera del LED. 7 3 7. Botón de encendido: Se utiliza para encender o apagar el aparato. 8. Botón de dormir: Se utiliza para establecer la función de dormir. 8 4 9. Botón del ventilador: Se utiliza para ajustar la velocidad del ventilador. El ventilador puede ajustarse a bajo, medio, alto y auto. 10. Botón de encendido del temporizador: se utiliza para configurar el temporizador de encendido automático. 5 12. Botón de ahorro de energía: Se utiliza para configurar la función de ahorro de energía. 13. Botón de bloqueo: Presione el botón °C/°F y el botón del temporizador al mismo tiempo para bloquear el control remoto y evitar que la configuración se cambie sin darse cuenta. 42 10 11 13 6 11. Botón de apagado del temporizador: se utiliza para configurar el temporizador de apagado automático. 9 12 INSTRUCCIONES DE OPERACIÓN PILAS DEL CONTROL REMOTO MODOS DE FUNCIONAMIENTO El mando a distancia requiere dos pilas alcalinas AAA (incluidas). Las baterías deben ser reemplazadas cuando: Hay cuatro modos de operación para elegir. Presione el botón de modo varias veces para elegir el modo deseado. La luz indicadora adyacente se iluminará para mostrar qué modo ha sido seleccionado. a) No se escucha ningún sonido al intentar programar el aparato. • Modo fresco b) El aparato no responde a una orden emitida por el mando a distancia. Elija el modo frío para configurar la función de enfriamiento. Use las flechas hacia arriba y hacia abajo para elegir la temperatura deseada. Cuando se selecciona el modo frío, la velocidad del ventilador se puede ajustar presionando el botón del ventilador. Cambio de batería: 1. Deslice la cubierta posterior del mando a distancia en la dirección de la flecha. • Modo seco 2. Inserte dos pilas AAA siguiendo la misma orientación que se muestra en el interior de la cámara de la batería (+/-). 4. Si el mando a distancia no se utilizará durante períodos de tiempo prolongados, las baterías se deben quitar. Elija el modo seco para eliminar el exceso de humedad del aire durante los períodos de alta humedad. Toda el agua extraída del aire se condensará dentro del aparato y drenará la parte posterior. La velocidad del ventilador se establecerá automáticamente y no se puede modificar en modo seco. Notas: • Modo de ventilador • Proteja el control remoto de altas temperaturas y manténgalo alejado de la exposición a la radiación. Elija el modo de ventilador para hacer funcionar el ventilador interno sin activar la función de enfriamiento. Presione el botón del ventilador varias veces para elegir la velocidad del ventilador. 3. Vuelva a instalar la cubierta trasera. • Mantenga el receptor del panel de control alejado de la luz directa del sol. • Modo automático • No mezcle baterías viejas y nuevas. • No mezcle pilas alcalinas, estándar (carbonozinc) o recargables (ni-cad, ni-mh, etc.). • El control remoto funciona a una distancia de 8 metros (26 pies) del receptor situado dentro del aparato principal. Cualquier obstrucción entre el receptor y el remoto puede causar interferencia de señal, limitando la capacidad de programar la unidad principal. El modo automático es un programa de fábrica preestablecido que define automáticamente el modo y la velocidad del ventilador en función de la temperatura establecida, la temperatura ambiente y la humedad ambiental. FLECHAS ARRIBA Y ABAJO Las flechas hacia arriba y hacia abajo modificarán la temperatura establecida en incrementos de 1°. Las flechas hacia arriba y hacia abajo modificarán el tiempo establecido de la función del temporizador en incrementos de 0,5 horas hasta 10 horas y luego en incrementos de 1 hora hasta 24 horas como máximo. 43 INSTRUCCIONES DE OPERACIÓN DORMIR SÍGUEME La función de dormir se puede utilizar para conservar energía durante las horas de dormir. Hay un sensor de temperatura integrado en el control remoto que controlará la temperatura ambiente. Mantenga el control remoto con usted y el aparato ajustará automáticamente la temperatura establecida en función de la temperatura donde se encuentre. Cuando se selecciona, la temperatura establecida aumentará en 1°C/2°F cada media hora durante una hora completa. El aparato mantendrá la nueva temperatura establecida durante 6 horas antes de volver automáticamente al funcionamiento normal. La función de dormir se puede cancelar en cualquier momento presionando el botón de dormir. AHORRADOR DE ENERGÍA La función de ahorro de energía encenderá y apagará automáticamente el ventilador cuando el compresor no esté en uso para minimizar la frecuencia con la que el compresor necesita encenderse. Cuando se selecciona, el ventilador continuará funcionando durante 3 minutos después de que se apague el compresor. El ventilador se encenderá durante 2 minutos en intervalos de 10 minutos hasta que la temperatura ambiente esté por encima de la temperatura establecida, momento en el cual el compresor se encenderá y se reanudará el enfriamiento. El control remoto mostrará la temperatura en su ubicación. El control remoto enviará una señal al aire acondicionado cada 3 minutos, siempre que permanezca dentro del alcance del aparato. La luz sígueme en el panel de control se iluminará durante 5 segundos cada 3 minutos para indicar que ha recibido una señal del control remoto. Si el aparato no recibe una señal del control remoto durante un intervalo de 7 minutos, emitirá un pitido para indicar que el modo Sígueme ha finalizado. La distancia máxima para la función sígueme es de 8 metros (26 pies). Esta característica está disponible en modos fresco y automático. CONEXIÓN INALÁMBRICA Este dispositivo se puede controlar con una aplicación inalámbrica en su dispositivo inalámbrico. Visite https://www.danby.com/support/#apps para descargar la aplicación y obtener información sobre su funcionamiento. 44 INSTRUCCIONES DE OPERACIÓN TEMPORIZADOR Uso de temporizadores de encendido y apagado simultáneamente El temporizador se puede usar para encender o apagar el aparato después de un período de tiempo establecido. Los temporizadores de encendido y apagado se pueden usar al mismo tiempo. El panel de control tiene un botón de temporizador. Presione una vez para configurar el temporizador de apagado automático y dos veces para configurar el temporizador de apagado automático. El control remoto tiene botones de encendido y apagado del temporizador separados. Para configurar el aparato para que se encienda, ejecute durante un período de tiempo establecido y luego apague, configure primero el temporizador de encendido automático y luego configure el temporizador de apagado automático. Para configurar el dispositivo para que funcione durante un período de tiempo, apague durante un período de tiempo y luego vuelva a encenderlo, configure primero el temporizador de apagado automático y luego configure el temporizador de encendido automático. Temporizador de encendido automático 1. Presione el botón del temporizador en el control remoto o presione el botón del temporizador en el panel de control dos veces. 2. Use las flechas hacia arriba y hacia abajo para seleccionar la cantidad de tiempo deseada antes de que el aparato se encienda. Ambas luces indicadoras se iluminarán y la pantalla hará una cuenta regresiva para que el aparato se apague o se encienda, cualquiera que sea la función que se configuró primero. 3. Use el botón de modo para seleccionar el modo deseado. 4. Use el botón del ventilador para seleccionar la velocidad deseada del ventilador. 5. El tiempo seleccionado aparecerá en el panel de visualización y hará una cuenta regresiva hasta que se encienda el aparato. Temporizador de apagado automático El temporizador no encenderá y apagará el electrodoméstico indefinidamente. Los temporizadores de encendido y apagado funcionarán una vez y luego el dispositivo volverá al funcionamiento normal. Apagar el dispositivo o desenchufarlo borrará todas las configuraciones de memoria, incluido el temporizador. 1. Presione el botón de apagado del temporizador en el control remoto o presione el botón del temporizador en el panel de control una vez. 2. Use las flechas hacia arriba y hacia abajo para seleccionar la cantidad de tiempo deseada antes de que el aparato se apague. El dispositivo se ejecutará en el modo seleccionado actualmente. 3. El tiempo seleccionado aparecerá en el panel de visualización y hará una cuenta regresiva hasta que el aparato se apague. 45 INSTRUCCIONES DE OPERACIÓN FILTRO DE AIRE LIMPIEZA El filtro de aire debe limpiarse aproximadamente cada 2 semanas. El filtro de aire puede requerir una limpieza más frecuente si hay caspa o pelaje en el aire. Para evitar posibles descargas eléctricas, asegúrese de que el aparato esté desenchufado antes de realizar cualquier limpieza o mantenimiento. El exterior del aparato se puede limpiar con un paño suave o con un paño tibio y húmedo si es necesario. Aproximadamente cada dos semanas, la luz indicadora del filtro en el panel de control se iluminará como un recordatorio para limpiar el filtro. Siga los pasos que se indican a continuación para limpiar el filtro y volver a ponerlo en funcionamiento normal. 1. El filtro de aire se encuentra detrás de la rejilla de admisión delantera. Para quitar el filtro de aire, sujete la lengüeta del filtro en el lado derecho de la parrilla y deslícela hacia la derecha. Si la rejilla de admisión delantera tiene dos muescas, tire de la parrilla hacia adelante para quitar el filtro de aire. 2. Utilice una aspiradora con un accesorio de cepillo suave para eliminar los residuos grandes o acumulación de polvo del filtro de aire. No utilice gasolina, benceno, diluyente o cualquier otro producto químico para limpiar este aparato ya que estas sustancias pueden dañar el acabado y la deformación de las piezas de plástico. Nunca vierta agua directamente sobre el aparato, ya que esto puede causar el deterioro de los componentes eléctricos y el aislamiento del cableado. CUIDADO DE FINAL DE TEMPORADA Antes de dejar el aparato en servicio durante el año, haga funcionar el aparato en modo de ventilador alto durante medio día para asegurarse 3. Lave el filtro en agua tibia jabonosa, por debajo de que el interior del aparato esté seco. Esto de 40°C (104°F), o utilice un agente de limpieza ayudará a evitar el crecimiento de moho o moho dentro del aparato. Asegúrese de que el filtro esté neutro. limpio y seco. Guarde el aparato en un lugar seco. 4. Enjuague el filtro con agua limpia y séquelo completamente antes de volver a instalarlo en el Nota: Al instalar o quitar el aparato de la ventana, asegúrese de que se tome precaución para evitar aparato. que caiga hacia atrás. Se recomienda que la instalación o remoción se complete con ayuda para 5. Pulse el botón de filtro en el panel de control evitar lesiones a personas o daños a la propiedad o para reanudar el funcionamiento normal. al aparato. Nota: No opere el aparato sin el filtro de aire instalado. DISPOSICIÓN CÓDIGOS DE ERROR Si el panel de visualización muestra alguno de los siguientes códigos de error, desenchufe el aparato, déjelo reposar durante 5-10 minutos y vuelva a enchufarlo. Si el error persiste, llame al servicio técnico. Compruebe la conformidad reglamentaria local con respecto a la eliminación aprobada y segura de este electrodoméstico. AS - Error del sensor de temperatura ambiente HI - Error del sensor de temperatura LO - Error del sensor de temperatura . - Error del sensor de temperatura del evaporador 46 SOLUCIÓN DE PROBLEMAS Danby cuidado del consumidor: 1-800-263-2629 o [email protected] Horas de operación: Lunes a Jueves 8:30 am - 6:00 pm Hora estándar del este Viernes 8:30 am - 4:00 pm Hora estándar del este La información de este manual está sujeta a cambios sin previo aviso. PROBLEMA El aparato no funcionará Enfriamiento insuficiente Ruido Olores El agua que gotea en el interior El agua que gotea fuera Acumulación de escarcha CAUSA POSIBLE • El enchufe no está completamente insertado en el tomacorriente de pared • Fusible fundido o disyuntor • El filtro de aire está sucio • Flujo de aire bloqueado • El tamaño del dispositivo es demasiado pequeño para la aplicación • Soporte inadecuado en la instalación de ventanas • Formación de moho o moho en superficies mojadas internas • Coloque un comprimido de algicida en el molde de la base; empuje la tableta a través de la parrilla a cada lado del aparato • El aparato no está correctamente inclinado para permitir que el agua se drene hacia el exterior • En días muy calurosos o húmedos, el agua goteada por la parte trasera del aparato es normal • Cuando las temperaturas exteriores están por debajo de 18.3°C (65°F) puede formarse escarcha cuando el aparato esté en modo de enfriamiento • Cambie el aparato al modo ventilador sólo hasta que el hielo se derrita Este aparato digital de Clase B cumple con la norma Canadiense ICES-003. CAN ICES-3 (B) 1. Reorientar o reubicar la antena receptora. 2. Aumente la separación entre el equipo y el receptor. Este equipo ha sido probado y cumple con los 3. Conecte el equipo a una toma de corriente en límites para un dispositivo digital de Clase B, de un circuito distinto al que está conectado el acuerdo con la Parte 15 de las Reglas de la FCC. receptor. Estos límites están diseñados para proporcionar una 4. Consulte al distribuidor oa un técnico de radio / protección razonable contra interferencias en una TV experimentado para obtener ayuda. instalación residencial. Los cambios o modificaciones no aprobados por Este equipo genera, utiliza y puede irradiar energía la parte responsable del cumplimiento de la FCC de radiofrecuencia y, si no se instala y utiliza podrían anular la autoridad del usuario para de acuerdo con las instrucciones, puede causar operar el equipo. interferencia en las comunicaciones de radio. Sin Este aparato cumple con la Parte 15 de las Reglas embargo, no hay garantía de que no se produzcan de la FCC. interferencias en una instalación en particular. El funcionamiento está sujeto a las dos condiciones Si este equipo causa interferencias en la recepción siguientes: de radio o televisión, lo que puede determinarse 1. Este dispositivo no puede causar interferencias. apagando y encendiendo el equipo, se recomienda 2. Este dispositivo debe aceptar cualquier al usuario que intente corregir la interferencia interferencia recibida, incluida la interferencia mediante una o más de las siguientes medidas: que pueda causar un funcionamiento no deseado. 47 GARANTÍA LIMITADA “ACARREADO LIMITED IN-HOME APPLIANCESOLAMENTE” WARRANTY Este de calidad contra defectos de fabricación, incluyendo mano obra, siempre y cuando Thisproducto quality product is warrantedestá to begarantizado free from manufacturer’s defects in material and workmanship, providedpartes that theyunit is deused under the normal operating la unidad se intended utilice bajo condiciones normales de funcionamiento para las que fue diseñado. conditions by thelas manufacturer. Esta solamente para quesold haya comprado esta unidad directamente de Danby Thisgarantía warranty isestá available only to thedisponible person to whom the la unitpersona was originally by Danby Productsoriginalmente Limited (Canada) or Danby Products Inc. (U.S.A.) (hereafter Products (Canada)distributor o Danby Products (U.S.A.) (en adelante “Danby”) o uno de sus distribuidores autorizados, y no es “Danby”) Limited or by an authorized of Danby, and isInc. non-transferable. transferible. CONDICIONES DE LA GARANTÍA TERMS OF WARRANTY Las piezas plásticas, se autorizan por treinta (30) días solamente a partir de la fecha de la compra, sin las extensiones Plastic parts, are warranted for thirty (30) days only from purchase date, with no extensions provided. proporcionadas. Primeros First Year 24 meses Durante lostwelve primeros veinticuatro (24)parts meses, parte buen will estado de este producto que resulte During the first (12) months, any functional of thiscualquier product found to been defective, be repaired or replaced, at warrantor’s defectuosa, incluyendo cualquier sistema sellado, será reparado o reemplazado, a opción del fabricante, sin option, at no charge to the ORIGINAL purchaser. cargo para el comprador original. To obtain reservesenthecontacto right to limit theelboundaries of “In Home Service” to the el proximity of an AuthorizedoService Depot.enAny app liance Póngase con distribuidor donde adquirió electrodoméstico póngase contacto con el Para obtener servicio Danby Service requiring outside the limited boundaries of “In Home , donde it will beeltheservicio consumer’s responsibility to transport centroservice de servicio autorizado más cercano deService” Danby, debe ser realizado portheunappliance técnico(at their own expense)Sitoeltheservicio original retailer (point of purchase) or a servicepersona depot forque repair.noSeesea “Boundaries of In Home Serv ice” below. cualificado. es realizado por cualquier un depósito de servicio autorizado, Contact from whom de yourDanby unit wasbajo purchased, contact your nearest authorized Danby service depot, where service todasyour lasdealer obligaciones estaorgarantía serán nulas. must be performed by a qualified service technician. Es responsabilidad comprador transportar el aparato centro deunit servicio autorizado If service is performed on thedel units by anyone other than an authorized servicealdepot, or the is used for commercialmás appli cercano. cation, all obligations of Danby under this warranty shall be void. Los cargos de transporte desde y hacia el lugar de servicio no están protegidos por esta garantía y son responsabilidad del comprador. Boundaries of If the appliance is installed in a location that is 100 kilometers (62 miles) or more from the nearest service center your unit must be In Home Service delivered to the nearest authorized Danby Service Depot, as service must only be performed by a technician qualified and certif ied for Nada dentro de esta garantía implica que Transportation Danby serácharges responsable por daño queprotected hayanbysufrido los alimentos warranty service by Danby. to and from thecualquier service location are not this warranty and are t u otros he contenidos de este aparato, ya sea a un defecto del aparato, o su uso, adecuado o inadecuado. responsibility of thedebido purchaser. EXCLUSIONES Nothing within this warranty shall imply that Danby will be responsible or liable for any spoilage or damage to food or other c ontents of this appliance, whether due Salvo lo aquí indicado por Danby, no existen otras garantías, condiciones o representaciones, explícitas o implícitas, concretas o to any defect of the appliance, or its use, whether proper or improper. intencionales por parte de Danby o sus distribuidores autorizados y todas las demás garantías, condiciones o representaciones, incluyendo cualquier garantía, condiciones o representaciones bajo cualquier Acta de Venta de Productos o legislación o estatuto EXCLUSIONS similar, quedan de esta forma expresamente excluidas. Salvo lo aquí indicado, Danby no serán responsables por ningún daño a Save as herein provided, Danby, there are no other warranties, conditions, representations or oguarantees, express or implied, m causado ade orpor intended by Danby or itsde la personas o bienes, incluyendo la propia unidad, sin importar su causa, de ningún daño indirecto el desperfecto authorized distributors andesta all other warranties, conditions, representations guarantees, including any warranties, conditioa Danby ns, representations or guarantees unidad, y al comprar unidad, el comprador acepta pororla presente, indemnizar y proteger contra cualquier reclamo under any Sale of Goods Actoorbienes like legislation or statue is hereby expressly excluded. Save as herein provided, Danby shall no t be responsible for any damages por daños a personas causados por la unidad. to persons or property, including the unit itself, howsoever caused or any consequential damages arising from the malfunction o the unit, the purchaser does hereby agree to indemnify and hold harmless Danby from any claim for damages to persons or propert CONDICIONES GENERALES f the unit and by the purchase of y caused by the unit. No se considerará ninguna de estas garantías o seguros cuando el daño o la necesidad de reparación sea el producto de los siguientes casos: GENERAL PROVISIONS 1) Falla del suministro eléctrico. No warranty or insurance herein contained or set out shall apply when damage or repair is caused by any of the following: 2) Daños en tránsito o durante el transporte de la unidad. 1) Power failure. 3) Alimentación incorrecta, como bajo voltaje, instalación eléctrica defectuosa o fusibles inadecuados. 4) Accidente, modificación, abuso o the usoappliance. incorrecto del artefacto, tal como insuficiente ventilación del ambiente o condiciones de 2) Damage in transit or when moving operación anormales (temperatura ambiente extremadamente o baja).fuses. 3) Improper power supply such as low voltage, defective house wiring alta or inadequate 5) Utilización comercial o industrial (v.g., si el electrodoméstico no está instalado en una vivienda particular). 4) Accident, abuserobo, or misuse of the appliance such hostilidades, as inadequate airactos circulation the room or abnormal con inundaciones, ditions 6) Incendio, dañosalteration, por agua, guerra, disturbios, de infuerza mayor comooperating huracanes, etc. high ordebido low roomatemperature). 7) Pedidos(extremely de servicio desinformación del usuario. 8) Instalación inadecuada instalación unappliance electrodoméstico o uso de un aparato al aire libre que no esté 5) Use for commercial or(v.g., industrial purposes (ie.de If the is not installedindependiente in a domestic residence). aprobado para aplicaciones pero no limitado 6) Fire, water damage, theft,en war,exteriores, riot, hostility,incluyendo acts of God such as hurricanes, floodsa: etc.garajes, patios, porches o cualquier lugar que no esté bien aislado o controlado por el clima). 7) Service calls resulting in customer education. 8) Improper (ie.la Building-in of acompra free standing appliance or using an appliance outdoorsconservar that is not approved for out de venta. door application). Se requerirá una Installation prueba de fecha de para reclamaciones de garantía; las facturas En el caso de que seProof requiera servicio debegarantía, el comprobante depósito autorizado. of purchase date will required forpresente warranty claims; so, please retainde billscompra of sale. Inathenuestro event warranty servicedeis serviciorequired, present this document to our AUTHORIZED SERVICE DEPOT. Danby Products Limited PO Box Products 1778, Guelph, Ontario, Canada N1H 6Z9 Danby Limited Telephone: (519) 837-0920 FAX:Ontario, (519) 837-0449 PO Box 1778, Guelph, Canada N1H 6Z9 Telephone: (519) 837-0920 FAX: (519) 837-0449 Warranty Service In-home Servicio de Garantía Acarreado Solamente 1-800-263-2629 1-800-263-2629 04/17 04/09 Danby Products Inc. PO Box 669, Findlay, Ohio, U.S.A. Products 45840 Danby Inc. Telephone: (419)Findlay, 425-8627 FAX: (419)U.S.A. 425-862945840 PO Box 669, Ohio, Telephone: (419) 425-8627 FAX: (419) 425-8629 NOTES / REMARQUES / NOTAS : __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ NOTES / REMARQUES / NOTAS : __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ MODEL • MODÈLE • MODELO DAC060EB7WDB Printed in China Imprimé en Chine Impreso en China Danby Products Limited, Guelph, ON, Canada N1H 6Z9 Danby Products Inc., Findlay, Ohio, USA 45840
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52

Danby DAC060EB7WDB El manual del propietario

Tipo
El manual del propietario