Kichler Lighting 9234AZ Manual de usuario

Tipo
Manual de usuario
1) Turn off power.
2) Remove outlet box screws from outlet box. Use 3/4” screws to assemble
mounting bar to outlet box.
3) Grounding instructions: (See Illus. A or B).
A) On fixtures where mounting strap is provided with a hole and two
raised dimples. Wrap ground wire from outlet box around green
ground screw, and thread into hole.
B) On fixtures where a cupped washer is provided. Attach ground wire
from outlet box under cupped washer and green ground screw, and
thread into mounting strap.
If fixture is provided with ground wire. Connect fixture ground wire to
outlet box ground wire with wire connector. (Not provided.) After following
the above steps. Never connect ground wire to black or white power
supply wires.
4) Make wire connections (connectors not provided.) Reference chart
below for correct connections and wire accordingly.
5) Assemble fixture to mounting bar using 5/8” screws.
INSTRUCTIONS FOR MOUNTING FIXTURE OUTDOORS AND/OR IN
WET LOCATION.
6) Mounting surface should be clean, dry, flat and 1/4” larger than the
canopy on all sides. Any gaps between the mounting surface and canopy
exceeding 3/16” should be corrected as required.
7) With silicone caulking compound, caulk completely around where back
of canopy meets the wall surface to prevent water from seeping into
outlet box.
Date Issued: 10/3/02
IS-9234-US
GREEN GROUND
SCREW
CUPPED
WASHER
A
B
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
(NOT PROVIDED)
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth)
*Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire
3/4” SCREWS
TORNILLOS DE 3/4"
5/8” SCREW
TORNILLOS DE 5/8"
1) Desconecte la corriente eléctrica.
2) Quite los tornillos del caja de salida, de la caja de salida. Utilice los
tornillos de 3/4" para montar la barra de montaje a la caja de salida.
3) Instrucciones de conexión a tierra solamente para los Estados
Unidos. (Vea la ilustracion A o B).
A) En las lámparas que tienen el fleje, de montaje con un agujero y
dos hoyuelos realzados. Enrollar el alambra tierra de la caja toma
corriente alrededor del tornillo verde y pasarlo por el aquiero.
B) En las lámparas con una arandela acopada. Fijar el alambre a
tierra de la caja tomacorriente del ajo de la arandela acoada y
tornillo verde, y paser por el fleje de montaje.
Si la lámpara viene con alambre a tierra. Conecter el alambre a tierra de
la lámpara al alambre a tierra de la caja tomacorriente con un conector
de alambres. (No incluido) Espués de seguir los pasos anteriores. Nunca
conectar el alambra a tierra a los alambres eléctros negro o blanco.
4) Haga les conexiones de los alambres (no se proveen los connectores.)
La tabla de referencia de abajo indica las conexiones correctas y los
alambres correspondientes.
6) Monte el artefacto a la barra de montaje utilizando los tornillos de 5/8".
INSTRUCCIONES PARA EL MONTAJE DEL ARTEFACTO AL AIRE LIBRE
Y/O EN UN LUGAR MOJADO.
7) La superficie de montaje debe estar limpia, seca, ser plana y 1/4" más
grande que el esdudete en todos los bordes. Cualquier espacio libre
entre la superficie de montaje y el escudete que exceda de 3/16" debe
corregirse según se requiera.
8) Calafatee totalmente con compuesto de calafatear de silicona alrededor
donde el escudete sienta en la superficie de la pared para impedir la
entrada de agua en la caja de conexiones
ARANDELA
CONCAVA
A
B
TIERRA DE LA
CAJA DE SALIDA
TORNILLO DE TIERRA,
VERDE
DEPRESIONES
TIERRA
ARTEFACTO
CONECTOR DE ALAMBRE
(NO SE PROVEE)
TIERRA DE LA
CAJA DE SALIDA
TORNILLO DE TIERRA,
VERDE
TIERRA
ARTEFACTO
Conectar el alambre de
suministro negro o rojo al
Conectar el alambre de
suministro blanco al
Negro Blanco
*Cordon paralelo (redondo y liso)
*Cordon paralelo (cuadrado y estriado)
Claro, marrón, amarillio o negro
sin hebra identificadora
Claro, marrón, amarillio o negro
con hebra identificadora
Alambre aislado (diferente del verde)
con conductor de cobre
Alambre aislado (diferente del
verde) con conductor de plata
*Nota: Cuando se utiliza alambre paralelo
(SPT I y SPT II). El alambre neutro es de forma
cuadrada o estriada y el otro alambre será de
forma redonda o lisa. (Vea la ilustracíón).
Hilo Neutral
OUTLET BOX
CAJA DE CONEXION
MOUNTING BAR
BARRE DE MONTAJE
FIXTURE
CAJA DE LA UNIDAD
SILICONE
MASILLA DE SILICE

Transcripción de documentos

OUTLET BOX CAJA DE CONEXION MOUNTING BAR BARRE DE MONTAJE 3/4” SCREWS TORNILLOS DE 3/4" SILICONE MASILLA DE SILICE FIXTURE CAJA DE LA UNIDAD 5/8” SCREW TORNILLOS DE 5/8" 1) 2) 1) 2) 3) Turn off power. Remove outlet box screws from outlet box. Use 3/4” screws to assemble mounting bar to outlet box. Grounding instructions: (See Illus. A or B). A) On fixtures where mounting strap is provided with a hole and two raised dimples. Wrap ground wire from outlet box around green ground screw, and thread into hole. B) On fixtures where a cupped washer is provided. Attach ground wire from outlet box under cupped washer and green ground screw, and thread into mounting strap. If fixture is provided with ground wire. Connect fixture ground wire to outlet box ground wire with wire connector. (Not provided.) After following the above steps. Never connect ground wire to black or white power supply wires. A 3) Desconecte la corriente eléctrica. Quite los tornillos del caja de salida, de la caja de salida. Utilice los tornillos de 3/4" para montar la barra de montaje a la caja de salida. Instrucciones de conexión a tierra solamente para los Estados Unidos. (Vea la ilustracion A o B). A) En las lámparas que tienen el fleje, de montaje con un agujero y dos hoyuelos realzados. Enrollar el alambra tierra de la caja toma corriente alrededor del tornillo verde y pasarlo por el aquiero. B) En las lámparas con una arandela acopada. Fijar el alambre a tierra de la caja tomacorriente del ajo de la arandela acoada y tornillo verde, y paser por el fleje de montaje. Si la lámpara viene con alambre a tierra. Conecter el alambre a tierra de la lámpara al alambre a tierra de la caja tomacorriente con un conector de alambres. (No incluido) Espués de seguir los pasos anteriores. Nunca conectar el alambra a tierra a los alambres eléctros negro o blanco. A B CONECTOR DE ALAMBRE (NO SE PROVEE) TIERRA DE LA CAJA DE SALIDA B OUTLET BOX GROUND FIXTURE GROUND TIERRA DE LA CAJA DE SALIDA FIXTURE GROUND DIMPLES GREEN GROUND SCREW 4) DEPRESIONES OUTLET BOX GROUND TORNILLO DE TIERRA, VERDE GREEN GROUND SCREW CUPPED WASHER 4) Make wire connections (connectors not provided.) Reference chart below for correct connections and wire accordingly. Connect Black or Red Supply Wire to: Connect White Supply Wire to: Black White *Parallel cord (round & smooth) *Parallel cord (square & ridged) Clear, Brown, Gold or Black without tracer Clear, Brown, Gold or Black with tracer Insulated wire (other than green) with copper conductor Insulated wire (other than green) with silver conductor *Note: When parallel wires (SPT I & SPT II) are used. The neutral wire is square shaped or ridged and the other wire will be round in shape or smooth (see illus.) 5) TIERRA ARTEFACTO TIERRA ARTEFACTO WIRE CONNECTOR (NOT PROVIDED) TORNILLO DE TIERRA, VERDE Haga les conexiones de los alambres (no se proveen los connectores.) La tabla de referencia de abajo indica las conexiones correctas y los alambres correspondientes. Conectar el alambre de suministro negro o rojo al Conectar el alambre de suministro blanco al Negro Blanco *Cordon paralelo (redondo y liso) *Cordon paralelo (cuadrado y estriado) Claro, marrón, amarillio o negro sin hebra identificadora Claro, marrón, amarillio o negro con hebra identificadora Alambre aislado (diferente del verde) con conductor de cobre Alambre aislado (diferente del verde) con conductor de plata *Nota: Cuando se utiliza alambre paralelo (SPT I y SPT II). El alambre neutro es de forma cuadrada o estriada y el otro alambre será de forma redonda o lisa. (Vea la ilustracíón). Neutral Wire ARANDELA CONCAVA 6) Hilo Neutral Monte el artefacto a la barra de montaje utilizando los tornillos de 5/8". Assemble fixture to mounting bar using 5/8” screws. INSTRUCTIONS FOR MOUNTING FIXTURE OUTDOORS AND/OR IN WET LOCATION. 6) Mounting surface should be clean, dry, flat and 1/4” larger than the canopy on all sides. Any gaps between the mounting surface and canopy exceeding 3/16” should be corrected as required. 7) With silicone caulking compound, caulk completely around where back of canopy meets the wall surface to prevent water from seeping into outlet box. Date Issued: 10/3/02 INSTRUCCIONES PARA EL MONTAJE DEL ARTEFACTO AL AIRE LIBRE Y/O EN UN LUGAR MOJADO. 7) La superficie de montaje debe estar limpia, seca, ser plana y 1/4" más grande que el esdudete en todos los bordes. Cualquier espacio libre entre la superficie de montaje y el escudete que exceda de 3/16" debe corregirse según se requiera. 8) Calafatee totalmente con compuesto de calafatear de silicona alrededor donde el escudete sienta en la superficie de la pared para impedir la entrada de agua en la caja de conexiones IS-9234-US
  • Page 1 1

Kichler Lighting 9234AZ Manual de usuario

Tipo
Manual de usuario

En otros idiomas