Kichler Lighting 45864CH Manual de usuario

Tipo
Manual de usuario

Este manual también es adecuado para

CAUTION – RISK OF SHOCK – Disconnect Power at the main
circuit breaker panel or main fuse box before starting and
during the installation.
Before Installing: All installations should comply with National and
Local Electrician Codes. If you have any doubts concerning instal-
lation, contact a qualified licensed electrician.
1) Find the appropriate threaded holes on mounting strap.
Assemble mounting screws into threaded holes.
2) Attach mounting strap to outlet box. (Screws not provided).
Mounting strap can be adjusted to suit position of fixture.
3) Grounding instructions: (See Illus. A or B).
A) On fixtures where mounting strap is provided with a hole
and two raise dimples. Wrap ground wire from outlet
box around green ground screw, and thread into hole.
B) On fixtures where a cupped washer is provided. Attach
ground wire from outlet box under cupped washer and
green ground screw, and thread into mounting strap.
If fixture is provided with ground wire. Connect fixture
ground wire to outlet box ground wire with wire connector.
(Not provided.) After following the above steps. Never connect
ground wire to black or white power supply wires.
4) Make wire connections (connectors not provided.) Reference
chart below for correct connections and wire accordingly.
5) Push fixture to wall, carefully passing mounting screws
through holes in canopy. Make sure all wires are inside
canopy and do not get pinched between wall and canopy of
fixture.
6) Thread lockup knobs onto mounting screws and tighten to
secure fixture to wall.
7) Carefully raise glass to the fixture. Slip the smaller opening
over the socket and fit the glass against the socket cover.
8) Thread socket ring onto socket. Tighten socket ring to secure
glass in place (DO NOT over tighten).
9) Insert recommended bulb (Not supplied).
PRECAUCIÓN – RIESGO DE DESCARGA ELÉCTRICA – Desco-
necte la electricidad en el panel principal del interruptor
automático o caja principal de fusibles antes de comenzar y
durante la instalación.
Antes de la instalación: Todas las instalaciones deben cumplir
con los códigos de electricista nacionales y locales. En caso de
duda sobre la instalación, póngase en contacto con un electricista
cualificado.
1) Encontrar los agujeros roscados correctos en la abrazadera
de montaje. Instalar los tornillos de montaje en los agujeros
roscados.
2) Unir la abrazadera de montaje a la caja de conexiones. (No se
proveen tornillos). La abrazadera de montaje puede ajustarse
para acomodar la posición del artefacto.
3) Instrucciones de conexión a tierra solamente para los
Estados Unidos. (Vea la ilustracion A o B).
A) En las lámparas que tienen el fleje, de montaje con un
agujero y dos hoyuelos realzados. Enrollar el alambre a
tierra de la caja tomacorriente alrededor del tornillo
verde y pasarlo por el aquiero.
B) En las lámparas con una arandela acopada. Fijar el
alambre a tierra de la caja tomacorriente del ajo de la
arandela acoada y tornillo verde, y paser por el fleje de
montaje.
Date Issued: 08/18/17 IS-45862-US
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
A
B
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth) *Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire
Were here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
Si la lámpara viene con alambre a tierra. Conecter el
alambre a tierra de la lámpara al alambre a tierra de la caja
tomacorriente con un conector de alambres. (No incluido)
Espués de seguir los pasos anteriores. Nunca conectar el
alambra a tierra a los alambres eléctros negro o blanco.
4) Haga les conexiones de los alambres (no se proveen los
connectores.) La tabla de referencia de abajo indica las
conexiones correctas y los alambres correspondientes.
5) Empuje la fijación a la pared, pasando cuidadosamente los
tornillos de montaje a través de los orificios de la cubierta.
Asegúrese de que todos los cables estén dentro del dosel y
no queden atrapados entre la pared y el dosel del aparato.
6) Enrosque los mandos de bloqueo en los tornillos de montaje
y apriételos para fijar el fijador a la pared.
7) Levante con cuidado el cristal al aparato. Deslice la abertura
más pequeña sobre el zócalo y ajuste el vidrio contra la
cubierta del zócalo.
8) Enrosque el anillo del casquillo. Apriete el anillo del zócalo
para asegurar el vidrio en su lugar (NO lo apriete demasiado).
9) Inserte la bombilla recomendada (no suministrada).
ARANDELA
CONCAVA
TIERRA DE LA
CAJA DE SALIDA
TORNILLO DE TIERRA,
VERDE
DEPRESIONES
TIERRA
ARTEFACTO
CONECTOR DE ALAMBRE
TIERRA DE LA
CAJA DE SALIDA
TORNILLO DE TIERRA,
VERDE
TIERRA
ARTEFACTO
A
B
Conectar el alambre de
suministro negro o rojo al
Conectar el alambre de
suministro blanco al
Negro Blanco
*Cordon paralelo (redondo y liso)
*Cordon paralelo (cuadrado y estriado)
Claro, marrón, amarillio o negro
sin hebra identificadora
Claro, marrón, amarillio o negro
con hebra identificadora
Alambre aislado (diferente del verde)
con conductor de cobre
Alambre aislado (diferente del
verde) con conductor de plata
*Nota: Cuando se utiliza alambre paralelo
(SPT I y SPT II). El alambre neutro es de forma
cuadrada o estriada y el otro alambre será de
forma redonda o lisa. (Vea la ilustracíón).
Hilo Neutral
(2) STRAP MOUNTING SCREWS
TORNILLOS DE MONTAJE DE LA ABRAZADERA
MOUNTING STRAP
ABRAZADERA DE MONTAJE
CANOPY
ESCUDETE
OUTLET BOX
CAJA DE SALIDA
WIRE
CONNECTORS
CONECTORES DE ALAMBRE
(2) MOUNTING
SCREWS
VIS DE MONTAGE
GLASS
VIDRIO
GLASS RETAINER
ANILLO DE RETENCIÓN DEL VIDRIO
SOCKET
PORTALÁMPARAS
  • Page 1 1

Kichler Lighting 45864CH Manual de usuario

Tipo
Manual de usuario
Este manual también es adecuado para

en otros idiomas