Cooper Lighting LZR203P Guía de instalación

Tipo
Guía de instalación
Installation Instructions For LZR203
Adjustable “L” and Straight Feed
Connector
NOTE: For use with LZR100 series Track systems only.
NOTE: Ground contact must be on the same side as
the Polarity Groove of the track. If Polarity Groove and
Ground Contact does not line up remove 2-screws
from cover, remove cover and adjust connector 180º
as shown. Install cover and screws. (If used as a
Power Feed DO NOT INSTALL COVER until wire con-
nections are made as noted below).
Electrical ratings: 120v, 60HZ, 20A.
Instructions d’installation du
connecteur réglable en “L” et linéaire
LZR203
REMARQUE : Seulement pour systèmes de rails
série LZR100.
REMARQUE : Le contact de terre doit être du même
côté que la gorge de polarité du rail. Si ce n’est pas le
cas, enlever les 2 vis du couvercle et le couvercle,
puis tourner le connecteur de 180º comme indiqué.
Installer le couvercle et les vis. (Si le connecteur sert
d’alimentation électrique, NE PAS INSTALLER LE
COUVERCLE tant que les fils ne sont pas connects
comme indiqu ci-dessous). Alimentation électrique:
120 V, 60 Hz, 20 A
Instrucciones de instalación para
el Conector de alimentación eléc-
trica recto y en “L” ajustable LZR203
NOTA: Para ser utilizado solamente con los sis-
temas de riel de la serie LZR100.
NOTA: El contacto a tierra tiene que quedar del
mismo lado que la Ranura de polaridad del riel. Si la
Ranura de polaridad y el Contacto de tierra no están
alineados, extraiga los 2 tornillos de la cubierta,
quite la cubierta y ajuste el conector 180° como se
muestra. Instale la cubierta y los tornillos, (Si se uti-
liza como un conector de Alimentación eléctrica NO
INSTALE LA CUBIERTA hasta que estén hechas las
conexiones de cable como se indica más abajo).
Capacidades nominales eléctricas: 120V,
60Hz, 20A
INSTALLATION INSTRUCTIONS
IMPORTANT SAFETY
INSTRUCTIONS
1. Read all of these installation instructions before
installing the track system.
2.
Save These Instructions
and refer to them when additions or changes in the
track configuration are made.
3. Disconnect electrical power before adding to or
changing the configuration of the track.
4. For use with LZR100 Series track systems only.
5. Electrical ratings: 120V, 60Hz, 20A
INSTRUCTIONS D’ INSTALLATION
IMPORTANTES CONSIGNES DE
SÉCURITÉ
1. Pour l’installation ou l’utilisation du présent système
sur rail, veullez prendre des mesures de sécurité de
base, y compris les mesures suivantes.
2.
Conserver ces instructions
et s’y reporter en cas d’ajouts ou de changements
au profil du système sur rail.
3. Couper le courant électrique avant de faire des
ajouts ou des changements au profil du rail.
4. Seulement pour systèmes de rails série LZR100.
5. Alimentation electrique: 120V, 60Hz, 20A
INSTRUCCIONES DE INSTALACIÓN
MEDIDAS IMPORTANTES DE
SEGURIDAD
1. Antes de conectar el sistema de rieles lea las
instrucciones para instalación
2.
Guarde estas instrucciones
y sigalas cada vez que se hagan adiciones o cam-
bios en la configuracion del sistema.
3. Desconecte el suministro eléctrico antes de hacer
adiciones o canbios en la configuración del
sistema.
4. Para ser utilizado solamente con los sistemas de
riel de la serie LZR 100.
5. Capacidades nominales eléctricas: 120V, 60Hz, 20A
LOCKING SCREW
VIS DE BLOCAGE
TORNILLO DE SEGURIDAD
POLARITY ARROW
FLECHE DE POLARITE
FLECHA DE POLARIDAD
GROUND SCREW VIS DE TERRE
CALIBRADOR DE PELADURA
SPACER
ENTRETOISE
PELADURA
POLARITY GROOVE
GORGE DE POLARITE
RANURA DE POLARIDAD
STRAIGHT FEED COVER
COUVERCLE DE CONNECTEUR LINÉAIRE
RANURA DE POLARIDAD
180º ADJUSTMENT
STRIP BARE
DENUDER
PELADURA
STRIP
GAUGE
“L” CONNECTOR COVER
COUVERCLE DU TRANSFORMATEUR EN L
CUBIERTA DEL CONVERTIDOR
POLARITY GROOVE
GORGE DE POLARITE
RANURA DE POLARIDAD
GABARIT DE DENUDAGE
CUBIERTA DE ALIMENTACION RECTA
RIGHT HAND
CÔTÉ DROIT
RECTO
STRAIGHT
LINÉAIRE
A LA DERECHA
LEFT HAND
CÔTÉ GAUCHE
A LA IZQUIERDA
Cooper Lighting
Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269
701159
STEP 1: Insert ends of connector into ends of track
(Polarity arrow must line up with Polarity Groove of
track.) Secure to track by tightening lock screws at
thetip of connector until snug. DO NOT OVER
TIGHTEN.
This may distort track.
IF USED AS A POWER FEED
POINT
STEP 1: Insert ends of connector into ends of track
(Ground Contact must line up with Polarity Groove of
track.) Secure to track by tightening lock screws at
the tip of connector until snug. DO NOT OVER
TIGHTEN.
This may distort track.
STEP 2: Remove plastic plug button from back
plate. Attach supply fitting (supplied by others) by
first threading spacer(supplied) then installing through
back plate and securing with speed nut (supplied by
others). NOTE: Spacer MUST be used to insure
proper assembly.
STEP 3: Strip supply wires to proper length using
gauge on inside of connector (1/2” nominal strip
length). Pull supply wires into connector. Connect
power supply wire (colored) to screw marked LINE
and neutral wire (white) to screw marked NEUT. If a
ground wire is
available it should be connected to the screw marked
GND. Wires must be routed as shown to assure
proper closure of connector cover.
ÉTAPE 1 : Insérer les extrémités du connecteur dans
les extrémités du rail (la flèche de polarité et la gorge
de polarité du rail doivent être alignées). Fixer le rail
en serrant les vis de serrage des extrémités du con-
necteur. NE PAS SERRER TROP FORT afin de ne pas
déformer le rail.
EN CAS D’UTILISATION COMME
POINT D’ALIMENTATION
ÉLECTRIQUE
ÉTAPE 1 :Insérer les extrémités du connecteur dans
les extrémités du rail (la fleche de polarité et la gorge
de polarité du rail doivent être alignées). Fixer au rail
en serrant les vis de serrage des extrémités du con-
necteur. NE PAS SER RER TROP FORT afin de ne pas
déformer le rail.
ÉTAPE 2 : Enlever le bouchon en plastique l’arrière
de la plaque. Monter l’applique d’alimentation élec-
trique (fournie par d’autres), en taraudant d’abord
l’entretoise (fournie), puis en introduisant cette
dernière depuis la plaque arrière et en la vissant avec
des écrous-tle (fournis par d’autres). REMARQUE :
L’entretoise DOIT être utilisée afin d’obtenir un
assemblage correct.
ÉTAPE 3 : Dénuder les fils d’alimentation sur une
longueur correcte en se référant au gabarit de
dnudage sur la face intrieure du connecteur (longueur
de dnudage nominale de 1/2 po). Introduire les fils
d’alimentation dans le connecteur. Connecter le fil
d’alimentation (color) la vis marque LINE et le fil neu-
tre (blanc) la vis marque NEUT. Si un fil de terre
esdisponible, le connecter la vis marque GND.
Placer les fils comme indiqu afin de pou voir fermer le
couvercle du connecteur.
PASO 1: Inserte los extremos del conector dentro de
los extremos del riel (la flecha de polaridad debe
quedar alineada con la Ranura de polaridad del riel).
Asegure la pieza al riel mediante apriete de los tornil-
los de cierre en la punta del conector hasta que que-
den a ras. NO APRIETE EN EXCESO. Esto pudiera
deformar el riel.
SI SE UTILIZA COMO UN PUNTO
DE ALIMENTACION ELECTRICA
PASO 1: Inserte los extremos del conector dentro de
los extremos del riel (el Contacto a tierra tiene que
quedar alineado con la Ranura de polaridad del riel).
Asegure la pieza al riel mediante apriete de los tornil-
los de cierre en la punta del conector hasta que que-
den a ras. NO APRIETE EN EXCESO. Esto pudiera
deformar el riel.
PASO 2: Extraiga el botón del tapón plástico de la
placa trasera. Una la conexión de suministro (a entre-
gar por terceros) primero enroscando el espaciador
(suministrado) y luego instalando a través de la placa
y asegurando con una tuerca de ajuste rápido (a
entregar por terceros). NOTA: Hay que utilizar espa-
ciador para asegurar un montaje apropiado.
PASO 3: Pele los cables de suministro eléctrico a la
longitud apropiada utilizando el calibrador en la parte
interior del conector (1/2” de longitud nominal de
peladura). Tire de los cables de suministro hacia el
interior del conector. Conecte el cable del suministro
eléctrico (de color) al tornillo marcado como LINE
(LINEA) y el cable neutral (blanco) al tornillo marcado
como NEUT (NEUTRO). Si hay un cable de tierra
disponible, éste debe ser conectado al tornillo marca-
do como GND (TIERRA.
Los cables tienen que estar situados como se muestra para
asegurar un cierre apropiado de la cubierta del conector.
Cooper Lighting
Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269
701159
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Cooper Lighting LZR203P Guía de instalación

Tipo
Guía de instalación