1) TURN OFF POWER.
IMPORTANT: Before you start, NEVER attempt any work
without shutting off the electricity until the work is done.
a) Go to the main fuse, or circuit breaker, box in your
home. Place the main power switch in the “OFF”
position.
b) Unscrew the fuse(s), or switch “OFF” the circuit breaker
switch(s), that control the power to the fixture or room
that you are working on.
c) Place the wall switch in the “OFF” position. If the fixture
to be replaced has a switch or pull chain, place those in
the “OFF” position.
2) Find the appropriate threaded holes on mounting strap.
Assemble mounting screws into threaded holes.
3) Attach mounting strap to outlet box. (Screws not provided).
Mounting strap can be adjusted to suit position of fixture.
4) Grounding instructions: (See Illus. A or B).
A) On fixtures where mounting strap is provided with a hole
and two raise dimples. Wrap ground wire from outlet
box around green ground screw, and thread into hole.
B) On fixtures where a cupped washer is provided. Attach
ground wire from outlet box under cupped washer and
green ground screw, and thread into mounting strap.
If fixture is provided with ground wire. Connect fixture
ground wire to outlet box ground wire with wire connector.
(Not provided.) After following the above steps. Never connect
ground wire to black or white power supply wires.
5) Make wire connections (connectors not provided.) Reference
chart below for correct connections and wire accordingly.
6) Push fixture to wall, carefully passing mounting screws
through holes.
7) Screw threaded balls onto mounting screws. Tighten
threaded balls to secure fixture to wall.
8) Raise glass up to fixture. Pass hole in glass over socket.
9) Thread socket ring onto socket. Tighten socket ring to
secure glass in place. (DO NOT over tighten.)
1) APAGUE LA ALIMENTACIÓN ELÉCTRICA.
IMPORTANTE: Antes de comenzar, NUNCA trate de trabajar
sin antes desconectar la corriente hasta que el trabajo se
termine.
a) Vaya a la caja principal de fusibles, o interruptor o caja
de circuitos de su casa. Coloque el interruptor de la
corriente principal en posición de apagado “OFF”.
b) Desatornille el (los) fusible (s), o coloque el interruptor o
interruptores del breaker en posición de apagado
“OFF”, que controla (n) la corriente hacia el artefacto o
habitación donde está trabajando.
c) Coloque el interruptor de pared en posición de apagado
“OFF”. Si el artefacto que se va a reemplazar tiene un
interruptor o cadena que se jala, colóquelos en la
posición de apagado “OFF”.
2) Encontrar los agujeros roscados correctos en la abrazadera
de montaje. Instalar los tornillos de montaje en los agujeros
roscados.
3) Unir la abrazadera de montaje a la caja de conexiones. (No se
proveen tornillos). La abrazadera de montaje puede ajustarse
para acomodar la posición del artefacto.
Date Issued: 7/17/15 IS-45190-US
WIRE CONNECTOR
(NOT PROVIDED)
OUTLET BOX
GROUND
FIXTURE
GROUND
GREEN GROUND
SCREW
DIMPLES
FIXTURE
GROUND
OUTLET BOX
GROUND
GREEN GROUND
SCREW
CUPPED
WASHER
A
B
Connect Black or Red
Supply Wire to:
Connect White Supply Wire to:
Black White
*Parallel cord (round & smooth)
*Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wire (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire
4) Instrucciones de conexión a tierra solamente para los
Estados Unidos. (Vea la ilustracion A o B).
A) En las lámparas que tienen el fleje, de montaje con un
agujero y dos hoyuelos realzados. Enrollar el alambre a
tierra de la caja tomacorriente alrededor del tornillo
verde y pasarlo por el aquiero.
B) En las lámparas con una arandela acopada. Fijar el
alambre a tierra de la caja tomacorriente del ajo de la
arandela acoada y tornillo verde, y paser por el fleje de
montaje.
Si la lámpara viene con alambre a tierra. Conecter el
alambre a tierra de la lámpara al alambre a tierra de la caja
tomacorriente con un conector de alambres. (No incluido)
Espués de seguir los pasos anteriores. Nunca conectar el
alambra a tierra a los alambres eléctros negro o blanco.
5) Haga les conexiones de los alambres (no se proveen los
connectores.) La tabla de referencia de abajo indica las
conexiones correctas y los alambres correspondientes.
6) Empuje la unidad contra la pared, pasando con cuidado al
tubo roscado a travès del agujero.
7) Atornille las bolas roscadas en los tornillos de montaje. Ariete
las bolas roscadas para sujetar el artefacto a la pared.
8) Levante el vidrio hasta el artefacto. Pasando el agujero en el
vidrio encima del casquillo.
9) Rosque el anillo del casquillo al casquillo. Apriete el anillo del
casquillo para sujetar el vidrio en el lugar. (NO apriete
excesivamente.)
Conectar el alambre de
suministro negro o rojo al
Conectar el alambre de
suministro blanco al
Negro Blanco
*Cordon paralelo (redondo y liso)
*Cordon paralelo (cuadrado y
estriado)
Claro, marrón, amarillio o negro
sin hebra identificadora
Claro, marrón, amarillio o negro
con hebra identificadora
Alambre aislado (diferente del
verde) con conductor de cobre
Alambre aislado (diferente del
verde) con conductor de plata
*Nota: Cuando se utiliza alambre paralelo
(SPT I y SPT II). El alambre neutro es de forma
cuadrada o estriada y el otro alambre será de
forma redonda o lisa. (Vea la ilustracíón).
Hilo Neutral
CONECTOR DE ALAMBRE
(NO SE PROVEE)
TIERRA DE LA
CAJA DE SALIDA
TIERRA
ARTEFACTO
TORNILLO DE TIERRA,
VERDE
DEPRESIONES
TIERRA
ARTEFACTO
TIERRA DE LA
CAJA DE SALIDA
TORNILLO DE TIERRA,
VERDE
ARANDELA
CONCAVA
A
B
Were here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
MOUNTING STRAP
PLANCHA PARA
MONTAR
THREADED BALL
BOLA ROSCADO
SOCKET RING
ANILLO DEL CASQUILLO
GLASS
VIDRIO
SOCKET
CASQUILLO